UV-SA 367-5455 INSTALLATION INSTRUCTIONS

Check List for Quick Set-Up
Aach bracketry according to instrucons found in this guide. See contents below. Aach the power cable to the circular jack 4 on the back of the UV-Clean unit. Power the device by plugging in the opposite end of the power cable to the supplied adapter, or another USB 3.0 device with output power of 900 mA. Set-up is complete.

1

UV-C Unit

3

4

5

Rear View

2
Front View

1. Status Indicator
White = On, Stand By Blue = Cleaning
Blue Blink = Bulb Failure

2. Moon Sensor
Detecon for UV auto shut-off
feature

3. Push Buon For Task Light
Control the on/off of the LED task Light

4. Power Receptacle
DC 5V supply included, 5mm jack

5. Micro-USB Data
Receptacle
Retrieve cleaning cycle informaon stored internally

Stand Tray

Short Screw (X2)

Micro-USB Data Cable
3/32" Allen Key

5mm , USB-A Power Cable DC 5V Power Supply

Cable Tie

White = On, Stand By

Blue = Cleaning

Blue Blink = Bulb Failure

SAFETY & DISPOSAL
Appropriate use of this product is expected and is the responsibility of the purchaser of this product. This product uses UV-C light. Eyes and skin should be kept from exposure. Eye inflammaon and skin irritaon can occur from prolonged exposure. For sensive skin, burns may occur. Do not touch the glass UV bulb surface. Fingerprints create a barrier and reduce UV ability.
Do not use this device on people, food, or pets. Keep out of Reach of Children. This product is not a toy. Do not aempt to disassemble this product. Nor is it serviceable. Warranty will be void. This UV bulb contains mercury in very small amounts. Precauons should be used to prevent breakage. Mercury may cause injury if swallowed and is known to cause reproducve harm. Dispose of this product responsibly per regulaons. Do not expose this product to water, liquids or moisture. Electricity is present. UV-C can discolor materials such as plasc and fabric over a period of me.
UV Bulb
Breakage: All visible bulb components should be cauonarily swept into a sealable bag, box or jar and taken outdoors. Cauon: The UV bulb contains a very small amount of mercury. As suggested by the EPA, do not vacuum up broken glass unless it is the only remaining debris. The same steps used to clean-up common CFL's may be used for this UV bulb. As listed here: hps://www.epa.gov/cfl/cleaning-broken-cfl
Recycling may be an opon in your area. www.lamprecycle.org/state-local-laws When done, this prevents mercury from entering the environment and reuse of glass, and metal is possible.
Refuse collecon can be handled by commercial waste contractors, municipalies, or other local household waste programs.

Internal Clock Baery
Baery disposal is controlled by law and requires proper acon.

Recycling and Refuse collecon can be handled by commercial waste contractors, municipalies, or other local household waste programs.
Resources

Locate centers near you: search.earth911.com

www.lamprecycle.org

EPA www.epa.gov Federal Universal Waste Rule

batteryresponsibility.org/battery-recycling

Maintenance
Do not aempt to service this product. Contact customer service at Proximity Systems for guidance. Do not subject the bulb to fingerprints, solvents or abrasion. Cleaning the bulb with a damp cloth or lens ssue is advised when the unit is not plugged in and the device is at room temperature only.

Environmental Condions for Operaon
Designed For 1. Commercial, Indoor use only 2. Altude up to 3050m 3. Working temperature: 20 - 27 degrees C (68-80 deg F). Humidity 20-90% (non-condensing).
Storage temperature: -20 - 55 degrees C (-4-130 deg F). Humidity <85% (non-condensing).

UV-SA SET-UP
Step 1:

Insert the power cable wire through the cable hole located near the top of the stand. Connue the
cable down the back of the stand.

Step 2: Locate pre-assembled poron
Note: Rotaon Stop

Tie the cabling in place. Step 3: Plug In Power

Long

(Factory Installed)

Short

This part will minimize free rotaon.

0 degrees
15 degrees
(FLAT SQUARE)

Step 4: Hang bracket onto stand

`Level' or, O degrees of rotation is recommended for this model. As shown above.

Long screw holds rotation position with a small amount of pressure.
Tighten until firm only.

Step 5: Plug In Power
(supplied adapter or a USB 3.0.)

Install 2 supplied screws.

Power is on.

UV-Clean HOW IT WORKS

Cleaning
When posioned and plugged into power, your UV-Clean device will begin working. It has pre-set operaon mes.
Cleaning cycles operate autonomously throughout the life of the product. Moon-sensor technology pauses cleaning cycles and relays the need to run a cleaning cycle when people come and go.

Operaon Timing

Clean Time: The period of me the device is producing UV-C. Factory set to 3 minutes.
No Moon Time: The length of me the device will allow to pass before producing UV-C aer the moon sensor has communicated an absence of movement. Factory set to 15 seconds.
Wait Time: Downme scheduled between cleaning cycles that are unrelated to moon sensor acvity. Factory set to 60 minutes.

SHEET REV D /2020

