MODEL FP5000 Configurable Pressure Transducer 008927 Issue 3 DESCRIPTION The Honeywell Model FP5000 Series is a media-isolated piezoresistive silicon

MODEL

MODEL FP5000 High Performance Configurable Pressure Transducer 008927 Issue 3 DESCRIPTION The Honeywell Model FP5000 Series is a media-isolated piezoresistive

Not Your Device? Search For Manuals / Datasheets:

File Info : application/pdf, 7 Pages, 475.62KB

Document
sps-siot-t-m-fp5000-pressure-datasheet-008927-1-en-ciid-177979
MODEL FP5000
High Performance Configurable Pressure Transducer

008927
Issue 3

DESCRIPTION
The Honeywell Model FP5000 Series is a media-isolated piezoresistive silicon pressure sensor offering multiple output options for reading pressure over the specified full-scale pressure span and temperature range. It is compensated for sensor offset, sensitivity, temperature effects and non-linearity to offer improved thermal stability and accuracy. Hastelloy C276 and 316L stainless steel wetted parts provide durability with abrasive or corrosive media.
DIFFERENTIATION
 Offers improved accuracy and reliability
 Configurable platform enables a sensor to be built to customer requirements. Simplified nomenclature and order codes make ordering easier
 Many pressure and operating temperature range options
 Built from stocked components; most configurations are shipped within ten business days
 Extensive history of pressure measurement know-how
 Bi-directional differential output available

FEATURES
 Pressure ranges from 10 in-H2O [0.36 psi] up to 5000 psi
 Gage, absolute, vacuum, barometric, compound, and differential wet/wet pressure types
 Higher accuracy to 0.1 %FSS BFSL
 Multiple output types: 0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, 4 mA to 20 mA, 5 Vdc 5 Vdc, 12 mA 8 mA
 Multiple electrical and pressure connection options
 Zero adjustment through potentiometer
 Operating temperature ranges from -40C to 125C [-40F to 250F]
 Multiple compensation temperature ranges
 Faster response and higher resolution
 Fully analog reduced-noise signal path provides continuous output resolution
 Stainless steel construction
 Ha C276 and 316L stainless steel wetted parts offer more enhanced durability with abrasive or corrosive media
 CE, RoHS, REACH compliant
 Intrinsic Safety Certifications: cFMus, ATEX, IEC Ex certified 2AR option (4 mA to 20 mA)
VALUE TO CUSTOMERS
 Built on the Honeywell history of higher-quality pressure sensing technologies
 Next-gen design of the popular FP2000 pressure sensor
 Offers more repeatable, reliable, and accurate pressure measurements over time
 Rugged, stainless steel pressure sensors are built and tested to perform and survive in many demanding environments
 Configurable platform creates a wide range of standard configurations
 Stocked components enable shipping within ten business days on most configurations

APPLICATIONS
 Test stands (Automotive, Aerospace, Industrial, and Medical)
 R&D test labs  Hydraulic and pneumatic system
monitoring  Leak detection  Manufacturing mold pressure control  Pump and compressor control  Liquid level measurement  Oil & gas process control  Fluid flow measurement  Valve testing
PORTFOLIO
Model FP5000 pressure transducers are part of a comprehensive line of Honeywell pressure sensors.

HIGH PERFORMANCE CONFIGURABLE PRESSURE TRANSDUCER MODEL FP5000

TABLE 1. PERFORMANCE SPECIFICATIONS

Characteristic

Measure

Operating pressure ranges
Accuracy1,7

Gage: 0.36 psi to 5000 psi Absolute: 5 psi to 5000 psi Vacuum: 0.36 psi to 15 psi Barometric: 0 to 30 in-Hg, 16 to 32 in-Hg, 26 to 32 in-Hg Compound ranges available consult factory Differential: 0.36 psi to 1000 psi Equivalent ranges are available in other pressure units also: kPa, bar, mm-Hg, in-Hg, mbar, torr, in-H2O
0.2 %FSS BFSL (Standard accuracy) 0.1 %FSS BFSL (High accuracy)

Output (selectable)

0 Vdc to 5 Vdc, 0 Vdc to 10 Vdc, or 4 mA to 20 mA (two wire)

Resolution

Continuous (Fully analog signal path)

TABLE 2. ENVIRONMENTAL SPECIFICATIONS

Characteristic

Measure

Operating temperature range See Table 3 (Electrical connectors)

Compensated temperature range

See Table 4 (Thermal effects error band)

Thermal effects error band (TEEB)2,3

See Table 4 (Thermal effects error band)

Sealing

See Table 3 (Electrical connectors)

Notes: 1. Accuracies stated are with respect to best fit straight line (BFSL) for
all errors including linearity, hysteresis, and non-repeatability through zero.
2. Thermal Effects Error Band - The maximum deviation in output due to changes in temperature over the entire compensated temperature range, relative to output measured at reference temperature. Includes all errors due to: Thermal Effect on Offset and Thermal Effect on Span.
3. Thermal effects error band (TEEB) increases pro-rata for pressure ranges below 5 psi [0.35 bar].
4. True Zero Output: The voltage output versions have onboard circuitry that allows the output signal to swing all the way to ground (True Zero) and even a little below (~-0.2 V). This mitigates increased error at lower voltage measurements.
5. Over pressure: The absolute maximum rating for pressure which may be safely applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressure may cause permanent damage to the product.
6. Burst pressure: The maximum pressure that may be applied to the product without causing escape of the pressure media. The product should not be expected to function after exposure to any pressure beyond the rated burst pressure.
7. All specifications apply at 25C [77F] and under operating conditions unless otherwise noted.
8. Full Scale Span (FSS): The algebraic difference between output signal measured at the upper and lower limits of the operating pressure range. Also known as "span".
9. Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as "null" or "zero".
10. Reference pressure: The pressure used as a reference (zero) in measuring product performance. Unless otherwise specified, this is vacuum (0 psia) for absolute pressure sensors and local ambient atmospheric pressure (0 psig) for gage/vacuum pressure sensors.
11. Minimum operating pressure: The lower limit of the operating pressure range.
12. Maximum line pressure: The maximum pressure that can be applied simultaneously to both ports of a Differential Pressure Sensor without causing changes in specified performance
13. Line pressure effect on zero: The change in the output at zero pressure caused by change in line pressure on both ports of differential
pressure sensor.

TABLE 3. ELECTRICAL CONNECTORS Connector Operating Temperature Range PT-02A-10-6P -40C to 125C [-40F to 250F] DIN FORM A -40C to 125C [-40F to 250F] DIN FORM C -40C to 90C [-40F to 194F] Integral cable -40C to 105C [-40F to 221F] Conduit fitting -40C to 105C [-40F to 221F] M12 x 1, 4-pin -40C to 85C [-40F to 185F]

Sealing IP67 IP65 IP65 IP67 IP67 IP67

TABLE 4. THERMAL EFFECTS ERROR BAND (TEEB)

Compensated

For Standard

Temperature Range Accuracy

For High Accuracy

0 C to 60 C [40 F to 140 F]

< 0.75 %FSS

< 0.5 %FSS

-20 C to 80 C [0 F to 180 F]

< 1.5 %FSS

< 1 %FSS

-40 C to 85 C [-40 F to 185 F]

< 2.25 %FSS

< 1.5 %FSS

-40 C to 125 C [-40 F to 250 F]

< 2.25 %FSS

< 1.5 %FSS

TABLE 5. MECHANICAL SPECIFICATIONS

Characteristic

Measure

Media

Gas, liquid

Weight (approx.)  gage, absolute, vacuum, barometric, compound

150 g [5.3 oz]

Weight (approx.)  differential

300 g [10.6 oz]

Wetted parts material

Ha C276 and 316L stainless steel

Labels

Laser engraved

Maximum allowed line pressure12

Operating range < 15 psi (1 bar):

50 psi

15 psi (1 bar) < Operating range  50 psi (3.5 bar):

250 psi

50 psi (3.5 bar) < Operating range  250 psi (17 bar):

Pressure range: +500 psi

250 psi (17 bar) < Operating range  1000 psi (70 bar):

Pressure range: +1000 psi

Line pressure effect on zero13

Operating range < 15 psi (1 bar):

1 % FSS

15 psi (1 bar) < Operating range  50 psi (3.5 bar):

1 % FSS

50 psi (3.5 bar) < Operating range  250 psi (17 bar):

1.5 % FSS

250 psi (17 bar) < Operating range  1000 psi (70 bar):

1.5 % FSS

Model FP5000 High Performance Configurable Pressure Transducer Datasheet | sps.honeywell.com/ast | 2

HIGH PERFORMANCE CONFIGURABLE PRESSURE TRANSDUCER MODEL FP5000

TABLE 6. ELECTRICAL SPECIFICATIONS7

Specifications

2AM, 2AR

2AY

4 mA to 20 mA 12 mA 8 mA

2AN 0 V to 5 V

2AP 0 V to 10 V

2AW 5 V 5 V

Supply voltage

9 Vdc to 28 Vdc

9 Vdc to 28 Vdc

14 Vdc to 28 Vdc

Current consumption

4 mA to 24 mA

< 6 mA

Output at reference pressure 10 (absolute, gage, vacuum, differential)
Output at minimum operating pressure11 - (compound, barometric)

4 mA 0.5 %FSS

12 mA 0.5 %FSS

0 V 0.5 %FSS

0 V 0.5 %FSS

5 V 0.5 %FSS

Full scale span (FSS)8

16 mA 1 %FSS 16 mA 1 %FSS

5 V 1 %FSS

10 V 1 %FSS

10 V 1 %FSS

Frequency response

3500 Hz

Reverse voltage protection

Yes, 28 V

Load impedance

< 950 Ohm at 28 V decreasing linearly to 0 Ohm at 9 V

> 10K Ohms

Insulation resistance

>500 MOhm to case GND at 33 V

Overvoltage protection

>32 V

Power up time

< 1 sec

Zero adjustment potentiometer

Yes, > 5 %FS adjustment, accessible from top after demounting connector

2AR not available for differential pressure sensing 2AY and 2AW are available only for bi-directional differential pressure sensing

TABLE 7. OVERPRESSURE AND BURST PRESSURE RATINGS

Pressure type/Port Operating Range

Over Pressure

Burst Pressure

Gage, absolute, vacuum, barometric, compound, differential version positive (high side)

 15 psi (1 bar) 15 psi to 1000 psi (1 bar to 70 bar) > 1000 psi (70 bar)

6X FS
4X FS 3X FS or 10,000 psi (700 bar) whichever is less

10X FS
6X FS 4X FS or 10,000 psi (700 bar) whichever is less

Differential version negative (low side) with respect to positive (high side)

 15 psi (1 bar) 15 psi to 1000 psi (1 bar to 70 bar)

6 X

10X

4X FS or 250 psi whichever is less 6X FS or 500 psi whichever is less

Model FP5000 High Performance Configurable Pressure Transducer Datasheet | sps.honeywell.com/ast | 3

HIGH PERFORMANCE CONFIGURABLE PRESSURE TRANSDUCER MODEL FP5000

TABLE 8. DIN FORM A (6M), DIN FORM C (6BO) WIRING

STANDARD

PIN

4 mA to 20 mA / 12 mA 8 mA (2AM, 2AR, 2AY)
Designation

0 V to 5 V/0 V to 10 V/ 5 V  5 V (2AN, 2AP, 2AW)
Designation

1

(+) Supply

(+) Supply

2

(+) Output

(+) Output

3

No connection

Supply return/ (-) Output

E

No connection

No connection

ALTERNATIVE 4 mA to 20 mA / 12 mA 8 mA (2AM, 2AR, 2AY) Designation (+) Supply (+) Output No connection Case GND

0 V to 5 V/0 V to 10 V/5 V  5 V (2AN, 2AP, 2AW) Designation (+) Supply Supply return/ (-) Output (+) Output Case GND

TABLE 9. PT02A-10-6P, 6-PIN (6A) WIRING

STANDARD

PIN

4 mA to 20 mA / 12 mA 8 mA (2AM, 2AR, 2AY)
Designation

0 V to 5 V/0 V to 10 V/ 5 V  5 V (2AN, 2AP, 2AW)
Designation

A

(+) Supply

(+) Supply

B

No connection

Supply return

C

No connection

(-) Output

D

(+) Output

(+) Output

E

No connection

No connection

F

No connection

No connection

ALTERNATIVE 4 mA to 20 mA / 12 mA 8 mA (2AM, 2AR, 2AY) Designation (+) Supply (+) Output No connection No connection No connection No connection

0 V to 5 V/0 V to 10 V/5 V  5 V (2AN, 2AP, 2AW) Designation (+) Supply (+) Output No connection Supply return/ (-) Output No connection No connection

TABLE 10. INTEGRAL CABLE (6Q), CONDUIT FITTING (6R) WIRING

STANDARD

ALTERNATIVE

PIN

4 mA to 20 mA / 12 mA 8 mA (2AM, 2AR, 2AY)
Designation

0 V to 5 V/0 V to 10 V/ 5 V  5 V (2AN, 2AP, 2AW)
Designation

4 mA to 20 mA / 12 mA 8 mA (2AM, 2AR, 2AY)
Designation

Red (+) Supply

(+) Supply

(+) Supply

Black (+) Output

Supply return

Not available

Green Not available

(-) Output

Not available

White Not available

(+) Output

(+) Output

0 V to 5 V/0 V to 10 V/5 V  5 V (2AN, 2AP, 2AW) Designation (+) Supply Supply return/ (-) Output Not available (+) Output

TABLE 11. M12 X 1, 4-PIN (6BJ) WIRING

STANDARD

PIN

4 mA to 20 mA / 12 mA 8 mA (2AM, 2AR, 2AY)
Designation

0 V to 5 V/0 V to 10 V/ 5 V  5 V (2AN, 2AP, 2AW)
Designation

1

(+) Supply

(+) Supply

2

No connection

(+) Output

3

(+) Output

Supply return/ (-) Output

4

Case GND

Case GND

ALTERNATIVE 4 mA to 20 mA / 12 mA 8 mA (2AM, 2AR, 2AY) Designation (+) Supply (+) Output No connection Case GND

0 V to 5 V/0 V to 10 V/5 V  5 V (2AN, 2AP, 2AW) Designation (+) Supply No connection Supply return/ (-) Output (+) Output

TABLE 12. INTRINSICALLY SAFE APPROVALS FOR OPTION 2AR (NOT AVAILABLE ON 2AM, 2AN, 2AP, 2AY, 2AW)

Agency

Approvals

cFMus

Class I, Div 1, Groups A, B, C, D Class I, Zone 0, AEx/Ex ia IIC T4/T5 Ga Ta= -40C to 40C (T5), -40C to 85C (T4)

ATEX

II 1 G Ex ia IIC T4/T5 Ga Ta= -40C to 40C (T5), -40C to 85C (T4)

IEC Ex

Ex ia IIC T4/T5 Ga Ta= -40C to 40C (T5), -40C to 85C (T4)

UKCA

II 1 G Ex ia IIC T4/T5 Ga Ta= -40C to 40C (T5), -40C to 85C (T4) (Pending Approval)

See Honeywell's website (http://sps.honeywell.com/ast) for up-to-date information regarding intrinsically safe approvals. Refer to Installation manual #008-0751-00 for installation/wiring instructions, cautions and warnings.

Model FP5000 High Performance Configurable Pressure Transducer Datasheet | sps.honeywell.com/ast | 4

HIGH PERFORMANCE CONFIGURABLE PRESSURE TRANSDUCER MODEL FP5000
Figure 1. Product Nomenclature
NFG 1 BR, 1AK, 2AM, 5F, 6M, 7BA

Type
NFG Gage NFA Absolute NFV Vacuum NFB Barometric (UG, UQ, UR only) NFC Compound (consult factory) NDW Differential, wet/wet

Accuracy

1 0.10 %* 2 0.20 %

*Not available in ranges < 2 psi *Not available for 2AY and 2AW

Range

kPa

bar

KD 35 kPa KF 100 kPa KG 200 kPa KH 300 kPa KJ 700 kPa KL 1000 kPa KM 1500 kPa KQ 3000 kPa KR 5000 kPa KS 7000 kPa KT**10000 kPa
in-H2O WA* 10 in-H2O WC* 20 in-H2O WE* 30 in-H2O WG* 50 in-H2O

ME 1 bar MF 2 bar NA 3.5 bar MG 5 bar NB 7 bar MH 10 bar MI 20 bar MJ 30 bar NC 35 bar MK 50 bar ND 70 bar ML** 100 bar NE** 135 bar MY** 200 bar NG** 350 bar
in-Hg
UG 30 in-Hg UQ 16-32 in-Hg UR 26-32 in-Hg

More ranges are available. Please consult Honeywell for options.

psi
AN* 0.5 psi AP* 1 psi AT 5 psi AV 10 psi BJ 15 psi BL 25 psi BM 30 psi BN 50 psi BP 75 psi BR 100 psi CJ 150 psi CL 200 psi CN 250 psi CP 300 psi CQ 400 psi CR 500 psi CS 600 psi CT 750 psi CV 1000 psi DJ** 1500 psi DL** 2000 psi DM** 2500 psi DN** 3000 psi DR ** 5000 psi

* Not available in absolute pressure type ** Not available in differential pressure type

Ranges with blue highlight (greater than 100 kPa, 15 psi, 1 bar) are NOT available in Vacuum.

Calibration Data*
5-point calibration at 77F (default option)
9A 9-point calibration at 77F
* Only positive side calibration data provided for differential sensors
Wiring 7BA Standard 7BB Alternative

Electrical Connection 6A PT02A-10-6P, 6-pin 6M DIN A 43650, 4-pin 6BO DIN C, 4-pin 6Q Integral cable, 5 feet# 6R Conduit fitting with 5 feet# cable 6BJ M12 x 1 (IEC 61076-2-101 style AM), 4-pin
#Consult factory for other cable lengths

Pressure Port

5A 1/4-18 NPT female

5B 1/4-18 NPT male 5D 7/16-20 UNF male 5F G1/4 B female

5G 5P 5AE 5I

G1/4 B male M12 x 1.5 male 1/2-14 NPT male 1/8-27 NPT male

Output
2AM 4 mA to 20 mA 2AN 0 Vdc to 5 Vdc 2AP 0 Vdc to 10 Vdc 2AR 4 mA to 20 mA Intrinsically Safe
(see Table 11 for certifications) 2AY 12 mA 8 mA 2AW 5 V 5 V
2AR not available for differential pressure sensing 2AY and 2AW are available only for bi-directional
differential pressure sensing

Temperature Compensation
1AK 0C to 60C [40F to 140F] 1Y1 -20C to 80C [0F to 180F] 1AP1 -40C to 85C [-40F to 185F] 1BA2 -40C to 125C [-40F to 250F]
1 1Y and 1AP not available for pressure ranges below 5 psi [0.35 bar] 2 1BA not available for pressure ranges below 50 psi [3.5 bar]

SAMPLE CATALOG LISTINGS

Order Code

Description

NFA1BM,1AK,2AP,5A,6A,7BA

Model FP5000; 0.10% accuracy; 30 psi absolute; compensated across 0C to 60C [40F to 140F]; 0 Vdc to 10 Vdc output; 1/4-18 NPT female port; PT02A-10-6P 6-pin electrical connector; standard wiring; 5-point calibration data at 77F

NFG2DR,1Y,2AR, 5G,6Q,7BB

Model FP5000; 0.20% accuracy; 5000 psi gage; compensated across -20C to 80C [0F to 180F]; Intrinsic Safety Certifications; 4 mA to 20 mA output; G 1/4 B male port; 5 ft long integral cable; alternative wiring; 5-point calibration data at 77F

NDW1BR,1AK,2AM,5F,6A,7BA

Model FP5000; 0.10 % accuracy; 100 psi differential; compensated across 0C to 60C [40F to 140F]; 4 mA to 20 mA output; G 1/4B female port, PT02A-10-6P 6-pin electrical connector; standard wiring; 5-point calibration data at 77F

Model FP5000 High Performance Configurable Pressure Transducer Datasheet | sps.honeywell.com/ast | 5

HIGH PERFORMANCE CONFIGURABLE PRESSURE TRANSDUCER MODEL FP5000
Figure 2. Mounting Dimensions
Model FP5000 High Performance Configurable Pressure Transducer Datasheet | sps.honeywell.com/ast | 6

ELECTRICAL TERMINATION

CODE 6BO: 4-PIN, MICRO DIN FORM C

CODE 6M: 4-PIN, STANDARD DIN 43650 FORM A

CODE 6A: 6-PIN, BENDIX CONNECTOR

CODE 6Q: 4-CONDUCTOR, CODE 6R: 4-CONDUCTOR,

CODE BJ: 4-PIN, M12 x 1

VENTED, INTEGRAL CABLE VENTED, 1/2-14 NPT CONDUIT (IEC 61076-2-101) STYLE AM

EXIT WITH INTEGRAL CABLE

26,0 [1.1]

 31,8 [1.3]

10,4 [0.4]

7,9 [0.3]

18,2 [0.7]

8,8 [0.3]

 31,8 [1.3]

21,3 [0.8]

n31,8 [1.3]
10,4 [0.4]

(35,8 ) [1.4]

 25,0 [1.0]

41,1 [1.6]

10,4 [0.4]

 31,8 [1.3]

27,2 [1.1]

 31,8 [1.3]
 25,0 [1.0]
8,8 [0.3]

 25,0 [1.0]

37,1 [1.5]

37,1 [1.5]

22,2 [0.9]
CHOOSE FROM PRESSURE PORTS CODES: 5F OR 5A

22,2 [0.9]
16,8 [0.7]
PRESSURE PORTS

CODE 5F: G 1/4 B FEMALE
22,2 [0.9]

CODE 5A: 1/4-18 NPT FEMALE
22,2 [0.9]

CODE 5G: G 1/4 B MALE
15,1 [0.6]

CHOOSE FROM ELECTRICAL TERMINATION CODES: 6BO, 6M, 6A, 6Q, 6BJ, OR 6R

 31,8 [1.3]
 25,0 [1.0]

CHOOSE FROM PRESSURE PORTS CODES: 5AE, 5G, 5P, 5B, 5D, OR 5I

CODE 5B: 1/4-18 NPT MALE
18,4 [0.7]

CODE 5D: 7/16-20 UNF MALE
16,8 [0.7]

CODE 5AE: 1/2-14 NPT MALE
18,0 [0.7]

 25,0 [1.0]

27,0 [1.1]

CODE 5P: M12 X 1.5 MALE
15,2 [0.6]

63,8 [2.5]
69,0 [2.7] CHOOSE FROM PRESSURE PORTS CODES: 5F OR 5A
CODE 5I: 1/8-27 NPT MALE
13,2 [0.5]

, CAUTION
PRODUCT DAMAGE DUE TO MECHANICAL ISSUES
 Ensure torque specifications are determined for the specific application. Mating materials and thread sealants can result in significantly different torque values from one application to the next.
 When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling. Ensure the sealant is rated for the application.
 Use appropriate tools (such as an open-ended wrench or deep-well socket) to install transducers.
 Always hand-start transducers into the hole to prevent cross threading and damage.
 Ensure that torque is not applied to the electrical connector.
 Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals can compromise ingress protection, leading to short circuits.
 To ensure proper environmental sealing and electrical connections when using a connector, follow the connector manufacturer's installation guidelines.
 All terminal cavities must be sealed using the correct wire gauge and seal combination.
 If only two leads are used, any additional terminal cavities should be sealed per the connector manufacturer's installation guide.
 Honeywell recommends using a crimping tool for crimping wires to the connector terminals.
 Contact the individual connector manufacturer for connector wiring.
Failure to comply with these instructions could result in product damage.
, NOTICE
Refer installation manual #008-0751-00 for installation/ wiring instructions, cautions and warnings related to Intrinsically Safe FP5000 (option 2AR).

FOR MORE INFORMATION

Honeywell Advanced Sensing Technologies services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing, or the nearest Authorized Distributor, visit sps.honeywell.com/ast or call:

USA/Canada Latin America Europe Japan Singapore Greater China

+302 327 8920 +1 305 805 8188 +1 302 327 8920 +81 (0) 3-6730-7152 +65 6355 2828 +86 4006396841

m WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury.
m WARNING
MISUSE OF DOCUMENTATION
 The information presented in this product sheet is for reference only. Do not use this document as a product installation guide.
 Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our literature and the Honeywell website, it is buyer's sole responsibility to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use.

Honeywell Advanced Sensing Technologies 830 East Arapaho Road Richardson, TX 75081 sps.honeywell.com/ast

Hastelloy is a registered trademark of Haynes International, Inc.
008927-3-EN | 3 | 08/21  2021 Honeywell International Inc.

