Owner's Manual for Intesis models including: IN775FGL00MO000, IN775FGL00MO000 VRF Systems to Modbus, IN775FGL00MO000, VRF Systems to Modbus, Systems to Modbus, to Modbus
Intesis Gateway, Installa on Manual, USB Configura on cable. Page 2 of 4. Page 3. Fujitsu VRF systems to Modbus TCP/RTU. Application. General. Not Included (in ...
Fujitsu VRF systems to Modbus TCP/RTU Application Item number: IN775FGL00MO000 The Fujitsu applica on has been specially designed to allow bidirec onal control and monitoring of Fujitsu VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client. The solu on allows the integra on of up to 64 indoor units from a single interface. Fujitsu to Modbus TCP/RTU - Up to 64 Indoor Units Features and benefits Simultaneous Modbus TCP and RTU management The gateway is a Modbus server and is able to manage both Modbus TCP and Modbus RTU simultaneously. Automa c iden fica on A scan func on is available for automa c iden fica on of the units present in the VRF system. Individual indoor unit energy consump on signals Energy consump on signals from each indoor unit are available, so they can be checked individually. Commissioning-friendly approach with Intesis MAPS Templates can be imported and reused as o en as needed, significantly reducing commissioning me. Direct access to the outdoor unit Connec on is simple, as the interface connects directly to the outdoor unit's communica on bus. Outdoor unit signals Signals assigned to the outdoor unit are available to be used in the integra on. Mul ple TCP client support The interface supports up to 6 TCP clients (incoming sockets). Configura on tool and interface automa c updates Both the Intesis MAPS configura on tool and the interface's firmware can receive automa c updates. Page 1 of 4 Fujitsu VRF systems to Modbus TCP/RTU Application General Net Width (mm) Net Height (mm) Net Depth (mm) Net Weight (g) Packed Width (mm) Packed Height (mm) Packed Depth (mm) Packed Weight (g) Opera ng Temperature °C Min Opera ng Temperature °C Max Storage Temperature °C Min Storage Temperature °C Max Power Consump on (W) Input Voltage (V) Power Connector Configura on Capacity Installa on Condi ons Content of Delivery 106 58 90 375 130 85 140 375 -10 60 -30 60 127 For DC: 12 .. 36 VDC ±10%, Max: 250 mA For AC: 24 VAC ±10 %, 50-60 Hz, Max: 127 mA Recommended voltage: 24 VDC, Max: 127 mA 3-pole Intesis MAPS Up to 64 indoor units and up to 12 outdoor units. This gateway is designed to be mounted inside an enclosure. If the unit is mounted outside an enclosure, precau ons should always be taken to prevent electrosta c discharge to the unit. When working inside an enclosure (e.g., making adjustments, se ng switches, etc.), typical an -sta c precau ons should always be followed before touching the unit. Intesis Gateway, Installa on Manual, USB Configura on cable. Page 2 of 4 Fujitsu VRF systems to Modbus TCP/RTU Application General Not Included (in delivery) Moun ng Housing Materials Warranty (years) Packaging Material Power supply not included. DIN rail mount (bracket included), Wall mount Plas c 3 years Cardboard Identification and Status Product ID IN775FGL00MO000_MBS_FGL Country of Origin Spain HS Code 8517620000 Export Control Classifica on Number (ECCN) EAR99 Physical Features Connectors / Input / Output Power supply, EIA-485, KNX, Ethernet, HVAC port, Binary inputs (dry contact), Console port USB. LED Indicators Gateway and communica on status. Push Bu ons Factory reset. I-Am message (for BACnet only). Normal mode/programming mode switch (for KNX only). DIP & Rotary Switches EIA-485 serial port configura on. Ba ery Descrip on Manganese Dioxide Lithium bu on ba ery. Certifications and Standards ETIM Classifica on EC001604 WEEE Category IT and telecommunica ons equipment Page 3 of 4 Fujitsu VRF systems to Modbus TCP/RTU Application Use Case Integra on example. Use Intesis MAPS to change the protocol: BACnet, Modbus, KNX, or Home Automa on Page 4 of 4PDFsharp 6.1.1