R-Foam Rigid Polyurethane Foam

1 giorno fa — Rheem reserves the right to make changes without notice. DESCRIPTION ... • Automatic thermostat keeps water at desired temperature. • Meets California ...

PDF preview unavailable. Download the PDF instead.

aws4 request&X-Amz-Signature=36e6ae6407c9954a05ede44641eaf2509dbaee06fd792f4d0d994056de26ba38
FaxBack # 2135
Standard Rheemglas® Energy Miser® Electric Water Heater

Available in 30, 40, 50, 65, 80 and 120 Gallon Tall ­ 30 and 50 Gallon Medium ­ 20, 30, 40, 47 and 50 Gallon Short Models

6-Year Limited Tank and Parts Warranty*
· Brass drain valve · Temperature and pressure relief valve
included
· Isolated tank design reduces conductive
heat loss
· High efficiency resistored heating elements · Anode rod equalizes aggressive water action · Electric junction box located above heating
elements for easy installation
· Over-temperature protector cuts off power in
excess temperature situations
· Automatic thermostat keeps water at desired
temperature
· Meets California Energy Commission
standards for new residential construction**

· Meets or exceeds requirements of the
National Appliance Energy Conservation Act (NAECA)

H E

HIGH EFFICIENCY MODELS FEATURE:

· High performance and recovery

· R-Foam® insulation process with

approx. R-value of R-20

· Compliant with many electric utility

incentive programs

*See Residential Warranty Information Brochure for complete warranty information. ** Title 24, Section 2-5352(i)

Energy Factor and Average Annual Operating

Costs based on D.O.E. (Department of Energy)

test procedures. D.O.E. national average fuel rate

®

electricity 8.41¢/KWH.

DESCRIPTION

FEATURES

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

ENERGY INFORMATION

T

Y P

GAL.

E

CAP.

MODEL NUMBER

FIRST HOUR RATING G.P.H.

RECOVERY IN G.P.H.
@ 90° RISE

TANK HEIGHT
A

HEIGHT TO WATER CONN.
B

DIAMETER C

APPROX. SHIP WT.
(LBS.)

ENERGY FACTOR

AVERAGE ANNUAL OPER. COST

APPROX. R-
FACTOR

30

T A HL

40 50

E L 65

80

MED. 50

30

40

T A L

40 50

L 65

80

120

MED.

30 50

S H

20 30

O 40

R 47 T 50

82VR30-2 82VR40-2 82VR52-2 82VR66-2 82VR80-2 82MVR52-2 81V30D 81V40D 81VH40D 81V52D 81V66D 81V80D 81V120D 81MV30D 81MV52D 81SV20D 81SV30D 81SV40D 81SV50D 81SV52D

47

21

45

45

19

82

0.93

$397 R-20

56

21

45-3/4

45-3/4

21

100

0.93

$397 R-20

61

21

56-1/2

56-1/2

21

118

0.93 92 $397 R-20

73

21

58-1/4

58-1/4

23

160

0.91

$406 R-20

92

21

58-1/2

58-1/2

24-1/2 180

0.91

$406 R-17.3

62

21

45-1/2

45-1/2

23

130

0.93 92 $397 R-20

48

21

45

45

17

76

0.91

$406 R-11.5

54

21

46

46

19

94

0.88

$420 R-11.5

53

21

58-1/2

58-1/2

17

96

0.91

$406 R-11.5

61

21

56-1/2

56-1/2

19

105

0.88

$420 R-11.5

71

21

58

58

21

150

0.88

$420 R-11.5

92

21

58-1/2

58-1/2

23

164

0.82

$450 R-11.5

110

21

62

62

28-1/4 324

0.81

$456 R-16.7

46

21

35-1/4

35-1/4

19

76

0.89

$415 R-11.5

63

21

45-1/2

45-1/2

21

114

0.86

$430 R-11.5

­

21

31

31

17

62

0.90

$410 R-11.5

41

21

29

29

21

90

0.89

$415 R-11.5

48

21

31-1/2

31-1/2

23

115

0.88

$420 R-11.5

55

21

32

32

26-1/4 147

0.87

$425 R-16.7

57

21

38-1/4

38-1/4

23

130

0.86

$430 R-11.5

· Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 watt upper and lower heating elements.

Recovery = wattage/2.42 x temp. rise °F.

· If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested. · Single element models available on special order (6000W max.). Substitute "S" for "D" in model number. · Special Wiring Options ­ A limited number of special wiring options are available. Consult factory for price and availability.

Example:

4500W = 21 GPH 2.42 x 90°

These units are designed to meet or exceed ANSI (American National Standards Institute) requirements and have been tested according to D.O.E. test procedures and meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, BOCA Code and all state energy efficiency performance criteria for energy consuming appliances.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.

R-Foam Rigid Polyurethane Foam
Monocellular rigid polyurethane foam insulation is formulated to provide low thermal conductivity.
This process forms a compact bubble pattern* around the tank. The uniform application minimizes the possibility of costly heat loss caused by numerous uninsulated areas discovered in earlier foam processes.
*Magnified over 10X.

WATER CONNECTIONS ALL 3/4" N.P.T. SIDE CONNECT RELIEF VALVE ON 81SV50D

In keeping with its policy of continuous progress and product improvement. Rheem reserves the right to make changes without notice.

Rheem Manufacturing Company · Water Heater Division · Post Office Box 244020 · Montgomery, Alabama 36124-4020

PRINTED IN U.S.A

11-99 WP

FORM NO. 101-5 Rev. 17

