LED T8 HYBRID - 15W

INSTALL INSTRUCTIONS (UL TYPE A & B)

General Installation Guidance

Important: Please find a qualified electrician for installation. Read these instructions before installing and using the linear tube(s).

General Requirements: All electrical connections must comply with LOCAL and NATIONAL ELECTRICAL CODE (N.E.C.) STANDARDS. If you are unfamiliar with proper electrical wiring connections, obtain the services of a qualified electrician. Remove the trim from the box and ensure no parts are missing.

Safety Warnings:

Safety Information:

Operational Modes:

UL TYPE A - DIRECT REPLACEMENT (Plug & Go™) INSTALLATION

⚠️DISCONNECT POWER BEFORE INSTALLING OR SERVICING.

Installation Steps:

  1. Make sure power is OFF.
  2. Remove lens or diffuser (if applicable).
  3. Remove existing fluorescent lamps from the luminaire. Note: Verify that the fluorescent tube type is listed on the LED lamp label. Check the ballast compatibility list before installation; only use lamps with qualified T8 fluorescent ballasts.
  4. Place the LED lamp in the luminaire and insert the lamp pins into the luminaire lampholders.
  5. Rotate the LED lamp until it locks in place. Ensure that the LED lamp front points away from the back of the luminaire.
  6. Note: Install one LED T8 replacement lamp for each fluorescent lamp removed.
  7. Place the lens or diffuser back in place (if applicable).
  8. Power On.

Diagram Description: Illustrates the placement and rotation of an LED T8 lamp into a luminaire's lampholders, ensuring the lamp locks in place with its front facing away from the luminaire's rear. It also shows a side-by-side comparison of a fluorescent lamp and an LED T8 lamp.

UL TYPE B - DIRECT WIRE (Ballast Bypass) DOUBLE ENDED INSTALLATION

⚠️DISCONNECT POWER BEFORE INSTALLING OR SERVICING.

Type B Lamp Description: Intended for operation in luminaires with traditional fluorescent-type lampholders wired directly to the branch circuit. This includes both factory-wired luminaires as well as those converted for this purpose under a retrofit program.

Read all WARNINGS before continuing this section.

This item is rated at 120-277VAC. The installer must determine whether line voltage 120-277V is available at the luminaire before installation.

Make sure POWER IS TURNED OFF AT THE SOURCE. Do not simply switch off the fixture.

Installation Steps:

  1. Remove existing covers from the light fixtures according to the light fixture manufacturer's instructions. Carefully remove the existing fluorescent tubes and dispose of them according to federal, state, and local laws.
  2. Cut off wires connected to the ballast, and remove the ballast (and starter, if present). Dispose of the removed ballast according to federal, state, and local laws.
  3. Connect Line (L) from the power source into the lamp holder. This will be "Line In".
  4. Connect Neutral (N) from the power source into the opposite end lamp holder. This will be "Neutral In".
  5. If installing a single tube, refer to the typical wiring diagrams on the following page. If connecting multiple lamps, continue reading.
  6. Connect a separate Line wire from the "Line out" of the primary source lamp holder and connect that wire into the "Line in" on the adjacent tube.
  7. Connect a separate neutral wire from the "Neutral out" of the primary source lamp holder and connect that wire into the "Neutral in" on the adjacent tube. Refer to typical wiring diagrams on the following page.
  8. This fixture is now powered as double-ended, for use with bypass tubes where opposite ends are marked with L and N, respectively.
  9. Install the double-ended bypass lamp into the wired lamp holders.
  10. Visibly affix a "Modification Sticker" and reinstall the housing cover and lens, if applicable. CAUTION: "This luminaire has been modified to operate LED lamps. Do not attempt to install or operate fluorescent lamps in this luminaire," shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance, including re-lamping.
  11. Return power to the source; the installation is now completed.

Dimming: If dimming is required (Type B), only operate with specific dimmers manufactured by Lutron: NTELV-300, CTELV-303P, DVELV-303P, or SELV-300P. Dimmers only operate on 120V.

Double Ended Wiring: The following ballast wiring represents a typical configuration. Actual ballast wiring varies according to the ballast model. It is not a requirement to change the sockets (if in good condition) to operate double-ended tubes, regardless of the socket type. Please ensure one side of the fixture is connected to Line (L) and the other side to Neutral (N).

Diagram Descriptions:

UL TYPE B - DIRECT WIRE (Ballast Bypass) SINGLE END INSTALLATION

⚠️DISCONNECT POWER BEFORE INSTALLING OR SERVICING.

Type B Lamp Description: Intended for operation in luminaires with traditional fluorescent-type lampholders wired directly to the branch circuit. This includes both factory-wired luminaires as well as those converted for this purpose under a retrofit program. This wiring method requires NON-SHUNTED lampholders (Fig. 1).

Read all WARNINGS before continuing this section.

This item is rated at 120-277VAC. The installer must determine whether line voltage 120-277V is available at the luminaire before installation.

Make sure POWER IS TURNED OFF AT THE SOURCE. Do not simply switch off the fixture.

Installation Steps:

  1. Remove existing covers from the light fixtures according to the light fixture manufacturer's instructions. Carefully remove the existing fluorescent tubes and dispose of them according to federal, state, and local laws.
  2. Cut off wires connected to the ballast, and remove the ballast (and starter, if present). Dispose of the removed ballast according to federal, state, and local laws.
  3. Connect Line (L) from the power source into one side of the non-shunted lamp holder. This will be "Line In".
  4. Connect Neutral (N) from the power source into the other side of the non-shunted lamp holder. This will be "Neutral In".
  5. If installing a single tube, refer to typical wiring diagrams on the following page. If connecting multiple lamps, continue reading.
  6. Connect a separate Line wire into "Line out" from the primary source lamp holder and connect that wire into "Line in" on the adjacent tube.
  7. Connect a separate neutral wire into "Neutral out" from the primary source lamp holder and connect that wire into "Neutral in" on the adjacent tube. Refer to typical wiring diagrams on the following page.
  8. This fixture is now powered at one end only, for use with bypass tubes where one end is marked with both L and N, for each pin respectively (Fig. 2).
  9. Install the lamp with the L and N markings into the wired lamp holder end.
  10. Visibly affix a "Modification Sticker" and reinstall the housing cover and lens, if applicable. CAUTION: "This luminaire has been modified to operate LED lamps. Do not attempt to install or operate fluorescent lamps in this luminaire," shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance, including re-lamping.
  11. Return power to the source; the installation is now completed.

Dimming: If dimming is required (Type B), only operate with specific dimmers manufactured by Lutron: NTELV-300, CTELV-303P, DVELV-303P, or SELV-300P. Dimmers only operate on 120V.

Diagram Descriptions:

Models: T8, T8 LED Tube, LED Tube, Tube

PDF preview unavailable. Download the PDF instead.

Updated PRE-79419 Manual - 914XXHYB Install 4475c7e1-aa60-47f0-a76a-f42a79c1bfa2 ?v=1699033728 Adobe PDF Library 17.0

Related Documents

PreviewLED T8 Super Hybrid U-Lamps Installation Instructions
Comprehensive installation guide for Sunco Lighting's LED T8 Super Hybrid U-Lamps, covering both Type A (Plug & Go) and Type B (Direct Wire) installation methods. Includes safety warnings, operational modes, and wiring diagrams.
PreviewLED T8 Tone-Select Super Hybrid Installation Instructions
Comprehensive installation guide for the LED T8 Tone-Select Super Hybrid tubes, covering both Type A (Plug & Go) and Type B (Direct Wire) installation methods. Includes safety precautions, wiring diagrams, and compatibility information.
PreviewSunco Lighting LED T8 Direct Wire Installation Guide
Detailed installation instructions for Sunco Lighting's LED T8 Direct Wire lamps, covering ballast bypass, safety precautions, and wiring for single and multiple lamp fixtures. Essential for electricians and facility managers.
PreviewSunco Lighting T8 LED Tube Ballast Bypass (Type B) Installation Guide
A comprehensive installation guide and manual for Sunco Lighting's T8 LED Tube Ballast Bypass (Type B). Includes easy installation steps, specifications, and important warnings for safe and proper setup.
PreviewSunco T8 Hybrid LED Tube User Manual: Installation and Troubleshooting
Comprehensive user manual for Sunco T8 Hybrid LED Tubes (Type A+B, Ballast Bypass). Includes installation guides for both with and without ballast, tombstone compatibility, wiring diagrams, product specifications, and troubleshooting tips.
PreviewSunco Lighting T8 Strip 2.0 LED Ready Fixture | Energy-Efficient Commercial Lighting
Explore the Sunco Lighting T8 Strip 2.0, a high-performance, energy-efficient LED ready fixture designed for various commercial and industrial applications. Features include direct wire compatibility, robust construction, UL listing, and a 5-year warranty.
PreviewLED 360° Downlight - Direct Wire Installation Instructions
Comprehensive installation instructions for the Sunco Lighting LED 360° Downlight (Direct Wire), covering safety precautions, wiring diagrams, and installation steps for replacing CFL, MHL, or HPS lamps.
PreviewSunco Lighting LED Ceiling Lights Installation Guide
Step-by-step installation instructions for Sunco Lighting LED Ceiling Lights, including safety warnings, parts list, and diagram descriptions. Learn how to safely install your new ceiling light.