BLU Products, Inc. BLUC5LMAX Smart Phone with GSM, WCDMA, LTE, Bluetooth and WiFi YHLBLUC5LMAX YHLBLUC5LMAX bluc5lmax
REPORT No.SZ21080255W03 TEST REPORT APPLICANT : BLU Products, Inc. PRODUCT NAME : Smart Phone MODEL NAME : C5L MAX BRAND NAME : BLU FCC ID : YHLBLUC5LMAX STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2021-09-15 TEST DATE : 2021-09-17 to 2021-10-15 ISSUE DATE : 2021-10-25 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 1 of 69 REPORT No.SZ21080255W03 DIRECTORY 1. Technical Information 3 1.1. Applicant and Manufacturer Information 3 1.2. Equipment Under Test (EUT) Description 3 1.3. Modulation Type and Data Rate of EUT 4 1.4. The Channel Number and Frequency 5 1.5. Test Standards and Results 6 1.6. Environmental Conditions 7 2. 47 CFR Part 15C Requirements 8 2.1. Antenna Requirement 8 2.2. Duty Cycle of Test Signal 9 2.3. Maximum Peak and Average Conducted Output Power 12 2.4. Bandwidth15 2.5. Conducted Spurious Emissions and Band Edge 22 2.6. Power Spectral Density32 2.7. Conducted Emission 39 2.8. Restricted Frequency Bands 43 2.9. Radiated Emission 53 Annex A Test Uncertainty 66 Annex B Testing Laboratory Information 67 Version 1.0 Change History Date 2021-10-25 Reason for change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 2 of 69 1. Technical Information REPORT No.SZ21080255W03 Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Applicant Address: Manufacturer: Manufacturer Address: BLU Products, Inc. 10814 NW 33rd St # 100 Doral, FL 33172,USA BLU Products, Inc. 10814 NW 33rd St # 100 Doral, FL 33172,USA 1.2. Equipment Under Test (EUT) Description Product Name: Sample No.: Hardware Version: Software Version: Modulation Technology: Modulation Type: Operating Frequency Range: Antenna Type: Antenna Gain: Accessory Information: Smart Phone 5# A507-MB-V3.6 BLU_C0170WW_V11.0.G.02.00_GENERIC 22-09-2021 13:40 DSSS, OFDM Refer to section1.3 802.11b/g/ n (HT20): 2412MHz2472MHz PIFA Antenna -0.28dBi Battery Brand Name: BLU Model No.: C775444200L Serial No.: N/A Capacity: 2000mAh Rated Voltage: 3.8V Charge Limit: 4.35V Manufacturer: Shenzhen Guihang Electronics Co., LTD MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 3 of 69 REPORT No.SZ21080255W03 AC Adapter Brand Name: BLU Model No.: US-FC-0750 Accessory Information: Serial No.: Rated Output: N/A 5.0V 750mA Rated Input: 100-240V 50/60Hz, 0.2A Manufacturer: Dongguan Keling Electronic Technology Co., LTD Note 1: We use the dedicated software to control the EUT continuous transmission. Note 2: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. 1.3. Modulation Type and Data Rate of EUT Modulation technology Modulation Type Data Rate (Mbps) Note1 DBPSK 1 DSSS (802.11b) DQPSK 2 CCK 5.5/ 11 BPSK 6 / 9 OFDM (802.11g) QPSK 16QAM 12 / 18 24 / 36 64QAM 48 / 54 BPSK 6.5 OFDM QPSK 13/19.5 (802.11n (HT20)) 16QAM 26/39 64QAM 52/58.5/65 Note1: The worst-case mode (bold face) in all data rates has been determined during the pre-scan, only the test data of the worst-case were recorded in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 4 of 69 REPORT No.SZ21080255W03 1.4. The Channel Number and Frequency Test Mode Channel Frequency (MHz) 1 2412 2 2417 3 2422 802.11b/g/n (HT20) 4 2427 5 2432 6 2437 7 2442 Note 1: The black bold channels were selected for test. Channel 8 9 10 11 12 13 Frequency (MHz) 2447 2452 2457 2462 2467 2472 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 5 of 69 1.5. Test Standards and Results REPORT No.SZ21080255W03 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT FCC ID Certification: No. Identity Document Title 1 47 CFR Part 15 Radio Frequency Devices Test detailed items/section required by FCC rules and results are as below: No. Section Description Test Date Test Engineer Result 1 15.203 Antenna Requirement N/A N/A PASS 2 N/A Duty Cycle Of Test Signal Sep 17, 2021 Meng Shurui PASS Maximum Peak and 3 15.247(b) Average Sep 19, 2021 Meng Shurui PASS Conducted Output Power Method Determination /Remark No deviation No deviation No deviation 4 15.247(a) Bandwidth Sep 19, 2021 Meng Shurui PASS No deviation Conducted 5 15.247(d) Spurious Emission and Sep 19, 2021 Meng Shurui PASS No deviation Band Edge Power 6 15.247(e) Spectral Sep 19, 2021 Meng Shurui PASS No deviation Density 7 15.207 Conducted Emission Oct 15, 2021 Su Zhan PASS No deviation Restricted 8 15.247(d) Frequency Oct 14, 2021 Huang Zhiye PASS No deviation Bands 9 15.209, Radiated 15.247(d) Emission Oct 13, 2021 Huang Zhiye PASS No deviation Note 1: The tests were performed according to the method of measurements prescribed in ANSIC63.10-2013, KDB558074 D01 v05r02. Note 2: The path loss during the RF test is calibrated to correct the results by the offset setting MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 6 of 69 REPORT No.SZ21080255W03 in the test equipments. The ref offset 11.0dB contains two parts that cable loss 1.0dB and Attenuator 10dB. Note 3: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 4: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. 1.6. Environmental Conditions During the measurement, the environmental conditions were within the listed ranges: Temperature (°C): 15-35 Relative Humidity (%): 30-60 Atmospheric Pressure (kPa): 86-106 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 7 of 69 REPORT No.SZ21080255W03 2. 47 CFR Part 15C Requirements 2.1. Antenna Requirement 2.1.1. Applicable Standard According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. 2.1.2. Result: Compliant Inside of the EUT has a PIFA antenna coupled with the metal shrapnel. Please refer to the EUT internal photos. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 8 of 69 2.2. Duty Cycle of Test Signal REPORT No.SZ21080255W03 2.2.1. Requirement Preferably, all measurements of maximum conducted (average) output power will be performed with the EUT transmitting continuously (i.e., with a duty cycle of greater than or equal to 98%). When continuous operation cannot be realized, then the use of sweep triggering/signal gating techniques can be used to ensure that measurements are made only during transmissions at the maximum power control level. Such sweep triggering/signal gating techniques will require knowledge of the minimum transmission duration (T) over which the transmitter is on and is transmitting at its maximum power control level for the tested mode of operation. Sweep triggering/signal gating techniques can then be used if the measurement/sweep time of the analyzer can be set such that it does not exceed T at any time that data are being acquired (i.e., no transmitter OFF-time is to be considered). When continuous transmission cannot be achieved and sweep triggering/signal gating cannot be implemented, alternative procedures are provided that can be used to measure the average power; however, they will require an additional measurement of the transmitter duty cycle (D). Within this subclause, the duty cycle refers to the fraction of time over which the transmitter is ON and is transmitting at its maximum power control level. The duty cycle is considered to be constant if variations are less than ±2%; otherwise, the duty cycle is considered to be nonconstant. 2.2.2. Test Description Test Setup: ANSI C63.10 2013 Clause 11.6 was used in order to prove compliance. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 9 of 69 2.2.3. Test Result A. Test Verdict: Test Mode 802.11b 802.11g 802.11n (HT20) B. Test Plot: REPORT No.SZ21080255W03 Duty Cycle (%) (D) 99.53 96.53 95.93 Duty Factor (10*lg[1/D]) 0.02 0.15 0.18 (Channel 1, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 10 of 69 REPORT No.SZ21080255W03 (Channel 1, 802.11g) (Channel 1, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 11 of 69 REPORT No.SZ21080255W03 2.3. Maximum Peak and Average Conducted Output Power 2.3.1. Requirement According to FCC section 15.247(b)(3), For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: The maximum peak conducted output power of the intentional radiator shall not exceed1 Watt. 2.3.2. Test Description The measured output power was calculated by the reading of the USB Wideband Power Sensor and calibration. Test Setup: Attenuator The EUT (Equipment under the test) which is coupled to the USB Wideband Power Sensor; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 12 of 69 REPORT No.SZ21080255W03 2.3.3. Test Result Maximum Peak Conducted Output Power 802.11b Mode Channel Frequency (MHz) Measured Output Peak Power dBm W 1 2412 18.54 0.071 7 2442 18.51 0.071 13 2472 17.98 0.063 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11g Mode Channel Frequency (MHz) 1 2412 7 2442 13 2472 Measured Output Peak Power dBm W 20.46 0.111 20.31 0.107 20.15 0.104 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11n (HT20) Mode Channel Frequency (MHz) 1 2412 7 2442 13 2472 Measured Output Peak Power dBm W 20.06 0.101 19.67 0.093 19.75 0.094 Limit dBm W 30 1 Verdict PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 13 of 69 REPORT No.SZ21080255W03 Maximum Average Conducted Output Power 802.11b Mode Channel Frequency (MHz) Measured dBm Average Power Duty Duty Factor Calculated Factor dBm W 1 2412 16.28 16.30 0.043 7 2442 15.02 0.02 15.04 0.032 13 2472 16.10 16.12 0.041 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11g Mode Channel Frequency (MHz) 1 2412 7 2442 13 2472 Measured dBm 13.10 14.11 14.90 Average Power Duty Duty Factor Calculated Factor dBm W 13.25 0.021 0.15 14.26 0.027 15.05 0.032 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11n (HT20) Mode Channel Frequency (MHz) 1 2412 7 2442 13 2472 Measured dBm 11.71 10.73 11.69 Average Power Duty Duty Factor Calculated Factor dBm W 11.89 0.015 0.18 10.91 0.012 11.87 0.015 Limit dBm W 30 1 Verdict PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 14 of 69 2.4. Bandwidth REPORT No.SZ21080255W03 2.4.1. Requirement According to FCC section 15.247(a) (2), Systems using digital modulation techniques may operate in the 902 - 928 MHz, 2400 - 2483.5 MHz, and 5725 - 5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz. 2.4.2. Test Description Test Setup: The EUT is coupled to the Spectrum Analyzer; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 100 kHz. In order to make an accurate measurement, set the span greater than RBW. 2.4.3. Test Procedure KDB 558074 Section 8.2 was used in order to prove compliance. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 15 of 69 2.4.4. Test Result 802.11b Mode A. Test Verdict: Channel Frequency (MHz) 1 2412 7 2442 13 2472 B. Test Plot: REPORT No.SZ21080255W03 6 dB Bandwidth (MHz) 9.019 9.538 8.587 Limits(kHz) 500 500 500 Result PASS PASS PASS (Channel 1, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 16 of 69 REPORT No.SZ21080255W03 (Channel 7, 802.11b) (Channel 13, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 17 of 69 802.11g Mode A. Test Verdict: Channel Frequency (MHz) 1 2412 7 2442 13 2472 B. Test Plot: REPORT No.SZ21080255W03 6 dB Bandwidth (MHz) 16.35 16.38 15.69 Limits(kHz) 500 500 500 Result PASS PASS PASS (Channel 1, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 18 of 69 REPORT No.SZ21080255W03 (Channel 7, 802.11g) (Channel 13, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 19 of 69 802.11n (HT20) Mode A. Test Verdict: Channel Frequency (MHz) 1 2412 7 2442 13 2472 B. Test Plot: REPORT No.SZ21080255W03 6 dB Bandwidth (MHz) 17.60 17.67 17.06 Limits(kHz) 500 500 500 Result PASS PASS PASS (Channel 1, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 20 of 69 REPORT No.SZ21080255W03 (Channel 7, 802.11n (HT20)) (Channel 13, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 21 of 69 REPORT No.SZ21080255W03 2.5. Conducted Spurious Emissions and Band Edge 2.5.1. Requirement According to FCC section 15.247(c), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. 2.5.2. Test Description Test Setup: The EUT is coupled to the Spectrum Analyzer; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 100 kHz. In order to make an accurate measurement, set the span greater than RBW. 2.5.3. Test Procedure KDB 558074 Section 8.5 and 8.7 was used in order to prove compliance. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 22 of 69 2.5.4. Test Result 802.11b Mode A. Test Verdict: Channel Frequency (MHz) 1 2412 7 2442 13 2472 Measured Max. Out of Band Emission (dBm) -43.89 -43.74 -43.82 B. Test Plot: REPORT No.SZ21080255W03 Limit (dBm) Carrier Calculated Level -20dBc Limit 6.43 -13.57 3.57 -16.43 6.55 -13.45 Verdict PASS PASS PASS (30MHz to 25GHz, Channel 1, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 23 of 69 REPORT No.SZ21080255W03 (Band Edge, Channel 1, 802.11b) (30MHz to 25GHz, Channel 7, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 24 of 69 REPORT No.SZ21080255W03 (30MHz to 25GHz, Channel 13, 802.11b) (Band Edge, Channel 13, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 25 of 69 REPORT No.SZ21080255W03 802.11g Mode A. Test Verdict: Channel Frequency (MHz) 1 7 13 B. Test Plot: 2412 2442 2472 Measured Max. Out of Band Emission (dBm) -44.24 -43.38 -43.67 Limit (dBm) Carrier Calculated Level -20dBc Limit 0.28 -19.72 -1.09 -21.09 0.77 -19.23 Verdict PASS PASS PASS (30MHz to 25GHz, Channel 1, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 26 of 69 REPORT No.SZ21080255W03 (Band Edge, Channel 1, 802.11g) (30MHz to 25GHz, Channel 7, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 27 of 69 REPORT No.SZ21080255W03 (30MHz to 25GHz, Channel 13, 802.11g) (Band Edge, Channel 13, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 28 of 69 REPORT No.SZ21080255W03 802.11n (HT20) Mode A. Test Verdict: Channel Frequency (MHz) 1 7 13 B. Test Plot: 2412 2442 2472 Measured Max. Out of Band Emission (dBm) -43.26 -44.49 -43.50 Limit (dBm) Carrier Calculated Level -20dBc Limit -1.20 -21.20 -4.15 -24.15 -2.87 -22.87 Verdict PASS PASS PASS (30MHz to 25GHz, Channel 1, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 29 of 69 REPORT No.SZ21080255W03 (Band Edge, Channel 1, 802.11n (HT20)) (30MHz to 25GHz, Channel 7,802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 30 of 69 REPORT No.SZ21080255W03 (30MHz to 25GHz, Channel 13, 802.11n (HT20)) (Band Edge, Channel 13, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 31 of 69 2.6. Power Spectral Density REPORT No.SZ21080255W03 2.6.1. Requirement For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be determined in accordance with the provisions of paragraph (b) of this section. The same method of determining the conducted output power shall be used to determine the power spectral density. 2.6.2. Test Description Test Setup: The EUT is coupled to the Spectrum Analyzer; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. 2.6.3. Test Procedure KDB 558074 Section 8.4 was used in order to prove compliance. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 32 of 69 REPORT No.SZ21080255W03 2.6.4. Test Result 802.11b Mode A. Test Verdict: Channel 1 7 13 B. Test Plot: Spectral power density (dBm/3kHz) Frequency (MHz) Measured PSD (dBm/3kHz) 2412 -9.62 2442 -10.54 2472 -9.85 Limit (dBm/3kHz) 8 8 8 Verdict PASS PASS PASS (Channel 1, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 33 of 69 REPORT No.SZ21080255W03 (Channel 7, 802.11b) (Channel 13, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 34 of 69 REPORT No.SZ21080255W03 802.11g Mode A. Test Verdict: Spectral power density (dBm/3kHz) Channel Frequency (MHz) Measured PSD (dBm/3kHz) 1 2412 -11.48 7 2442 -13.66 13 2472 -13.18 B. Test Plot: Limit (dBm/3kHz) 8 8 8 Verdict PASS PASS PASS (Channel 1, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 35 of 69 REPORT No.SZ21080255W03 (Channel 7, 802.11g) (Channel 13, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 36 of 69 REPORT No.SZ21080255W03 802.11n (HT20) Mode A. Test Verdict: Channel 1 7 13 Frequency (MHz) 2412 2442 2472 Spectral power density (dBm/3kHz) Measured PSD (dBm/3kHz) -14.19 -15.81 -13.89 B. Test Plot: Limit (dBm/3kHz) 8 8 8 Verdict PASS PASS PASS (Channel 1, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 37 of 69 REPORT No.SZ21080255W03 (Channel 7, 802.11n (HT20)) (Channel 13, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 38 of 69 2.7. Conducted Emission REPORT No.SZ21080255W03 2.7.1. Requirement According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency Range (MHz) Conducted Limit (dBµV) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 Note: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 2.7.2. Test Description Test Setup: The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10 2013. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 39 of 69 REPORT No.SZ21080255W03 2.7.3. Test Result The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT+Adapter+Earphone+WIFI TX Test Voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 40 of 69 B. Test Plot: REPORT No.SZ21080255W03 (L Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.4515 45.58 41.41 2 0.4961 48.86 41.95 3 0.5909 45.05 35.87 4 0.9112 44.71 32.69 5 1.3864 46.18 31.52 6 1.8292 43.30 32.06 Limit (dBµV) Quai-peak 56.85 56.06 56.00 56.00 56.00 56.00 Average 46.85 46.06 46.00 46.00 46.00 46.00 Power-line Verdict PASS PASS Line PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 41 of 69 REPORT No.SZ21080255W03 (N Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.4517 0.4517 40.22 2 0.5054 0.5054 40.47 3 0.6223 0.6223 34.89 4 0.9108 0.9108 32.04 5 1.0056 1.0056 34.88 6 1.9394 1.9394 35.38 7 5.7267 5.7267 29.88 Limit (dBµV) Quai-peak 56.84 56.00 56.00 56.00 56.00 56.00 60.00 Average 46.84 46.00 46.00 46.00 46.00 46.00 50.00 Power-line Verdict Neutral PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 42 of 69 2.8. Restricted Frequency Bands REPORT No.SZ21080255W03 2.8.1. Requirement According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a). 2.8.2. Test Description Test Setup The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 43 of 69 REPORT No.SZ21080255W03 2.8.3. Test Procedure KDB 558074 Section 8.6 and 8.7 was used in order to prove compliance. 2.8.4. Test Result The lowest and highest channels are tested to verify Restricted Frequency Bands. The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m Note: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (vertical) was recorded in this test report. 802.11b Mode A. Test Verdict: Receiver Max. Channel Frequency (MHz) Detector PK/ AV Reading UR (dBµV) AT (dB) AFactor (dB@3m) Emission E (dBµV/m) Limit (dBµV/m) Verdict 1 2381.20 PK 21.33 6.74 27.20 55.27 74 PASS 1 2390.00 AV 10.22 6.74 27.20 44.16 54 PASS 13 2483.81 PK 24.82 6.74 27.20 58.76 74 PASS 13 2483.50 AV 16.78 6.74 27.20 50.72 54 PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 44 of 69 B. Test Plot: REPORT No.SZ21080255W03 (PEAK, Channel 1, 802.11b) (AVERAGE, Channel 1, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 45 of 69 REPORT No.SZ21080255W03 (PEAK, Channel 13, 802.11b) (AVERAGE, Channel 13, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 46 of 69 REPORT No.SZ21080255W03 802.11g Mode A. Test Verdict: Channel Frequency (MHz) Detector PK/ AV Receiver Reading UR (dBµV) AT (dB) AFactor (dB@3m) Max. Emission E (dBµV/m) Limit (dBµV/m) Verdict 1 2389.38 PK 30.39 6.74 27.20 64.33 74 PASS 1 2390.00 AV 17.28 6.74 27.20 51.22 54 PASS 13 2485.18 PK 35.81 6.74 27.20 69.75 74 PASS 13 2484.08 AV 18.22 6.74 27.20 52.16 54 PASS B. Test Plot: (PEAK, Channel 1, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 47 of 69 REPORT No.SZ21080255W03 (AVERAGE, Channel 1, 802.11g) (PEAK, Channel 13, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 48 of 69 REPORT No.SZ21080255W03 (AVERAGE, Channel 13, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 49 of 69 REPORT No.SZ21080255W03 802.11n (HT20) Mode A. Test Verdict: Receiver Max. Channel Frequency (MHz) Detector Reading UR AT (dB) AFactor (dB@3m) Emission E Limit (dBµV/m) Verdict PK/ AV (dBµV) (dBµV/m) 1 2389.04 PK 27.72 6.74 27.20 61.66 74 PASS 1 2390.00 AV 14.74 6.74 27.20 48.68 54 PASS 13 2484.15 PK 32.39 6.74 27.20 66.33 74 PASS 13 2483.50 AV 17.63 6.74 27.20 51.57 54 PASS B. Test Plot: (PEAK, Channel 1, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 50 of 69 REPORT No.SZ21080255W03 (AVERAGE, Channel 1, 802.11n (HT20)) (PEAK, Channel 13, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 51 of 69 REPORT No.SZ21080255W03 (AVERAGE, Channel 13, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 52 of 69 2.9. Radiated Emission REPORT No.SZ21080255W03 2.9.1. Requirement According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) Field Strength (µV/m) Measurement Distance (m) 0.009 - 0.490 2400/F(kHz) 300 0.490 - 1.705 24000/F(kHz) 30 1.705 - 30.0 30 30 30 - 88 100 3 88 - 216 150 3 216 - 960 200 3 Above 960 500 3 Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. Note2: For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK). In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), also should comply with the radiated emission limits specified in Section 15.209(a)(above table). MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 53 of 69 2.9.2. Test Description Test Setup: 1) For radiated emissions from 9kHz to 30MHz REPORT No.SZ21080255W03 2) For radiated emissions from 30MHz to1GHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 54 of 69 3) For radiated emissions above 1GHz REPORT No.SZ21080255W03 The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode. For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector. For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements. The frequency range of interest is monitored at a fixed antenna height and EUT azimuth. The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 55 of 69 REPORT No.SZ21080255W03 2.9.3. Test Result According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average). The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 40GHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 56 of 69 802.11b Mode Plot for Channel 1 REPORT No.SZ21080255W03 Fre. (MHz) 55.220 345.250 1206.400 3711.880 7971.520 12132.600 PK (dBV/m) 29.33 28.90 44.55 45.21 46.56 47.17 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 106.630 305.480 757.500 2412.267 5646.120 10885.200 PK (dBV/m) 28.44 27.03 33.45 46.97 46.87 46.21 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 57 of 69 Plot for Channel 7 REPORT No.SZ21080255W03 Fre. (MHz) 110.510 342.340 1651.733 5353.520 8430.440 12129.520 PK (dBV/m) 28.51 28.34 44.77 46.11 46.45 46.88 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 107.600 381.140 1626.667 5766.240 10340.040 12471.400 PK (dBV/m) 28.85 27.91 45.22 46.39 46.76 47.35 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 58 of 69 Plot for Channel 13 REPORT No.SZ21080255W03 Fre. (MHz) 88.200 594.540 2406.400 5596.840 9101.880 12914.920 PK (dBV/m) 28.41 33.09 46.27 45.56 47.16 46.60 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 108.570 347.190 1196.800 2652.360 5744.680 12893.360 PK (dBV/m) 28.42 29.11 45.40 44.85 46.26 47.96 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 59 of 69 802.11g Mode Plot for Channel 1 REPORT No.SZ21080255W03 Fre. (MHz) 90.140 253.100 580.960 1959.467 6409.960 12206.520 PK (dBV/m) 28.41 27.77 32.16 44.73 45.57 47.46 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 107.600 417.030 2412.800 4525.000 8356.520 12144.920 PK (dBV/m) 29.25 29.17 46.27 45.58 46.81 46.72 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 60 of 69 Plot for Channel 7 REPORT No.SZ21080255W03 Fre. (MHz) 39.700 251.160 663.410 1878.933 4503.440 11134.680 PK (dBV/m) 27.67 27.00 32.17 45.99 45.63 46.83 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 54.250 105.660 904.940 5621.480 7953.040 10355.440 PK (dBV/m) 28.14 28.23 36.98 46.57 45.54 46.72 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 61 of 69 Plot for Channel 13 REPORT No.SZ21080255W03 Fre. (MHz) 53.280 199.750 1989.867 4309.400 8975.600 12298.920 PK (dBV/m) 28.24 26.34 45.37 45.22 46.24 47.68 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 57.160 290.930 648.860 1999.467 5729.280 10358.520 PK (dBV/m) 27.78 27.09 32.31 45.93 46.57 47.75 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 62 of 69 802.11n (HT20) Mode Plot for Channel 1 REPORT No.SZ21080255W03 Fre. (MHz) 51.340 379.200 1641.600 5643.040 8581.360 12209.600 PK (dBV/m) 29.31 28.94 45.23 46.21 47.21 46.56 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 97.900 297.720 1732.267 5609.160 8584.440 11913.920 PK (dBV/m) 27.28 27.76 45.39 46.41 47.53 46.51 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 63 of 69 Plot for Channel 7 REPORT No.SZ21080255W03 Fre. (MHz) 53.280 400.540 1212.800 4552.720 9120.360 12206.520 PK (dBV/m) 28.31 29.05 44.78 46.60 46.99 46.93 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 50.370 306.450 728.400 1599.467 4561.960 10968.360 PK (dBV/m) 28.43 27.68 32.30 45.34 45.68 46.69 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 64 of 69 Plot for Channel 13 REPORT No.SZ21080255W03 Fre. (MHz) 55.220 361.740 760.410 2408.000 5815.520 12613.080 PK (dBV/m) 27.73 28.21 33.65 46.46 46.69 47.61 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 52.310 108.570 596.480 2492.267 5356.600 12151.080 PK (dBV/m) 27.17 28.38 31.21 46.69 45.42 47.20 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 65 of 69 Annex A Test Uncertainty REPORT No.SZ21080255W03 Where relevant, the following measurement uncertainty levels have been estimated for test performed on the EUT as specified in CISPR 16-1-2: Test Items Uncertainty Peak Output Power ±2.22dB Power Spectral Density ±2.22dB Bandwidth ±5% Conducted Spurious Emission ±2.77dB Restricted Frequency Bands ±5% Radiated Emission ±2.95dB Conducted Emission ±2.44dB This uncertainty represent an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 66 of 69 REPORT No.SZ21080255W03 Annex B Testing Laboratory Information 1. Identification of the Responsible Testing Laboratory Laboratory Name: Laboratory Address: Telephone: Facsimile: Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 2. Identification of the Responsible Testing Location Name: Address: Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China 3. Facilities and Accreditations All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 67 of 69 REPORT No.SZ21080255W03 4. Test Equipments Utilized 4.1 Conducted Test Equipments Equipment Name Serial No. Attenuator 1 (N/A.) EXA Signal Analyzer MY53470836 USB Wideband Power Sensor MY54210008 RF Cable (30MHz-26GHz) CB01 Coaxial Cable CB02 SMA Connector CN01 Computer T430i Type 10dB N9010A Manufacturer Resent Agilent U2021XA Agilent RF01 Morlab RF02 RF03 Think Pad Morlab HUBER-SUHNER Lenovo Cal. Date N/A 2021.03.25 2020.10.23 N/A N/A N/A N/A Due Date N/A 2022.03.24 2021.10.22 N/A N/A N/A N/A 4.2 Conducted Emission Test Equipments Equipment Name Serial No. Type Receiver MY56400093 N9038A LISN 812744 NSLK 8127 Pulse Limiter (10dB) VTSD 9561 F-B #206 VTSD 9561-F Coaxial Cable(BNC) CB01 EMC01 (30MHz-26GHz) Manufacturer KEYSIGHT Schwarzbeck Cal. Date Due Date 2021.03.09 2022.03.08 2021.03.09 2022.03.08 Schwarzbeck 2021.07.21 2022.07.20 Morlab N/A N/A 4.3 List of Software Used Description Test System MORLAB EMCR V1.2 TS+ -[JS32-CE] Manufacturer Townsend MORLAB Tonscend Software Version V2.5.77.0418 V1.0 V2.5.0.0 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 68 of 69 REPORT No.SZ21080255W03 4.4 Radiated Test Equipments Equipment Name Serial No. Receiver MY54130016 Test Antenna Bi-Log 9163-519 Test Antenna Loop 1519-022 Test Antenna Horn 01774 Test Antenna BBHA9170 Horn #774 Coaxial Cable (N male) CB04 (9KHz-30MHz) Coaxial Cable (N male) CB02 (30MHz-26GHz) Coaxial Cable (N male) CB03 (30MHz-26GHz) Coaxial Cable (N male) CB05 (30MHz-40GHz) 1-18GHz pre-Amplifier 61171/61172 18-26.5GHz pre-Amplifier 46732 26-40GHz pre-Amplifier 56774 Notch Filter N/A Anechoic Chamber N/A Type N9038A VULB 9163 FMZB1519 BBHA 9120D BBHA9170 EMC04 EMC02 EMC03 EMC05 S020180L32 03 S10M100L38 02 S40M400L40 02 WRCG-24002483.5-60SS 9m*6m*6m Manufacturer Agilent Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck Morlab Morlab Morlab Morlab Tonscend Tonscend Tonscend Wainwright CRT Cal. Date 2021.07.16 2019.05.24 2019.02.14 2019.07.26 2019.07.26 N/A N/A N/A N/A 2021.07.16 2021.07.16 2021.07.16 2021.07.16 2020.01.06 Due Date 2022.07.15 2022.05.23 2022.02.13 2022.07.25 2022.07.25 N/A N/A N/A N/A 2022.07.15 2022.07.15 2022.07.15 2022.07.15 2023.01.05 END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 69 of 69Acrobat Distiller 9.3.2 (Windows)