User Manual for ARROW models including: AK-22123-CDC Lumen CVC for High Volume Infusions, Lumen CVC for High Volume Infusions, High Volume Infusions, Volume Infusions
AK-22123-CDC - Teleflex Incorporated - Vascular Access Product Catalog
File Info : application/pdf, 1 Pages, 515.98KB
DocumentDocumentAK-22123-CDC 12 3 Fr. Lumen 16 cm catheter length .035 inch dia. spring-wire guide Arrowg+ard Blue® Large-Bore Three-Lumen CVC for High Volume Infusions Contents: 1: Arrowg+ard Blue® Three-Lumen Catheter: 12 Fr. (4.1 mm OD) x 16 cm 1: Spring-Wire Guide, Marked: .035" (0.89 mm) dia. x 23-5/8" (60 cm) (Straight Soft Tip on One End - "J" Tip on Other) with Arrow Advancer 1: Catheter: 18 Ga. x 2-1/2" (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle 1: Injection Needle: 25 Ga. x 1" (2.54 cm) 1: Blunt Fill Needle: 18 Ga. x 1-1/2" (3.81 cm) 1: Pressure Transduction Probe 1: Introducer Needle: 18 Ga. x 2-1/2" (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe 1: Injection Needle: 22 Ga. x 1-1/2" (3.81 cm) and 5 mL Luer-Slip Syringe 1: Syringe: 3 mL Luer-Lock 1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep 1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®1 One-Step Solution with Hi-Lite OrangeTM Tint 1: SharpsAway® II Locking Disposal Cup 1: SharpsAway® Disposal Cup 1: Drape: 41" x 55" with 4" fenestration 1: Needle Holder 1: Safety Scalpel: #11 2: Gauze Pad: 2" x 2" (5 cm x 5 cm) 5: Gauze Pad: 4" x 4" (10 cm x 10 cm) 1: Suture: 3-0 Silk with Curved Needle 1A registered trademark of CareFusion or one of its subsidiaries. Rx only Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. California Prop. 65 WARNING: Cancer and Reproductive Harm. www.P65Warnings.ca.gov Not made with natural rubber latex. Store between 20 25°C (68 77°F). Sterilized using ethylene oxide unless otherwise indicated in the contents list. Fluid path components are non-pyrogenic. Contraindications: The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs. Lumen Priming Volume* (mL) Distal (16 Ga.) 0.35 Medial (12 Ga.) 1.2 Proximal (12 Ga.) 1.1 Gravity Flow Rate (mL/hr) 2581 9719 12666 * Priming volumes are approximate and are done without accessories. Flow rate values are approximate and are determined using deionized water at 100 cm head height. Arrow International LLC Subsidiary of Teleflex Incorporated 3015 Carrington Mill Blvd. Morrisville, NC 27560 USA LBL050972 R01 (2022-02) AK-22123-CDC 12 3 Fr. Lumen Arrowg+ard Blue® Large-Bore ThreeLumen CVC for High Volume Infusions 16 cm catheter length .035 inch dia. spring-wire guide