ChannelPlus H11XL - H17 XL Series 2 Installation Instructions

ChannelPlus H11XL - H17 XL Series 2 Installation Instructions ChannelPlus XL Single Channel Timeswitch offers up to three programmed operating periods per day, with

PDF ChannelPlus H11XL - H17 XL Series 2 Installation Instructions


File Info : application/pdf, 12 Pages, 1.86MB

PDF preview unavailable. Download the PDF instead.

ChannelPlusH11-17XL-installation for web-P82730 issue 6-NP0082730000
ChannelPlus H11XL - H17 XL Series 2 Installation Instructions
ChannelPlus XL Single Channel Timeswitch offers up to three programmed operating periods per day, with independent Boost and Advance control. This model has a fully graphical, back-lit display combined with simple menu driven programming.
Installation and connection should only be carried out by a suitably qualified person in accordance with the current edition of the IET wiring regulations. Warning: Isolate mains supply before commencing installation.

Fitting the Backplate
Once the Backplate has been removed from the packaging please ensure the timeswitch is re-sealed to prevent damage from dust, debris etc.
The Backplate should be fitted with the wiring terminals located at the top and in a position which allows the relevant clearances around the timeswitch. (See diagram)
50 mm

100 mm

N L 1 2 3 4 5 6 50 mm

50 mm
Direct Wall Mounting
Offer the plate to the wall in the position where the timeswitch is to be mounted, remembering that the Backplate fits to the right hand end of the timeswitch.
Mark the fixing positions through the slots in the Backplate (Fixing centres 60.3mm), drill and plug the wall, then secure the plate in position. The slots in the Backplate will compensate for any misalignment of the fixings.
2

Wiring Box Mounting
The Backplate may be fitted directly on to a single gang steel flush wiring box complying with BS4662, using two M3.5 screws.
ChannelPlus timeswitches are suitable for mounting on a flat surface only, they must not be positioned on a surface mounted wall box or on unearthed metal surfaces.
Electrical Connections
All necessary electrical connections should now be made. Flush wiring can enter from the rear through the aperture in the Backplate. Surface wiring can only enter from beneath the timeswitch and must be securely clamped.
The mains supply terminals are intended to be connected to the supply by means of fixed wiring. The recommended cable sizes are 1.0mm2or 1.5mm.2
ChannelPlus timeswitches are double insulated and do not require an Earth connection but an Earth terminal is provided on the Backplate for terminating any Earth connections. Earth continuity must be maintained and all bare Earth conductors must be sleeved. Ensure that no conductors are left protruding outside the central space enclosed by the Backplate.
When used to control MAINS VOLTAGE SYSTEMS Terminals L and 5 should be electrically linked by means of a suitable piece of sleeved conductor. When used to control EXTRA LOW VOLTAGE SYSTEMS these links MUST NOT be fitted.
3

Electrical Connections
Example circuit diagrams are shown on page 5 & 6. These diagrams are schematic and should be used as a guide only. Please ensure that all installations comply with the current IET regulations.
INTERNAL WIRING DIAGRAM H11XL - H17XL

NL

123456

E

N

L

MAINS SUPPLY

ON

ON

TIMED OUTPUT

For reasons of space and clarity the diagrams have been simplified, for instance some Earth connections have been omitted. Other control components shown in the diagrams i.e. Valves, RoomStats etc. are general representations only.
Cylinder and Room Thermostat Key: C = Common CALL = Call for heat or break on rise SAT = Satisfied on rise N = Neutral

4

Electrical Connections
Typical combination boiler installation with RoomStat
Combination boiler installation without RoomStat 5

Electrical Connections
Gravity primary with pumped Heating via RoomStat and CylinderStat
Fully Pumped System with RoomStat and two port spring return valve (with auxiliary switch) on Heating circuit
6

Commissioning the Timeswitch

Ensure all dust and debris has been cleared away from the work area before removing the timeswitch from its packaging. All ChannelPlus XL controls are fitted with battery reserve which maintains programmed times in the event of a mains power failure.

Rear View of ChannelPlus XL Timeswitch

1
6 543 21L N
3
4

2

5

REMOVE LINK (IF FITTED) FOR GRAVITY SYSTEMS

1 - RETAINING SCREWS 2 - CONNECTOR BLADES 3 - PRODUCTION DATE LABEL 4 - POSITIONING LUGS 5 - RATINGS LABEL

Fitting the Timeswitch

If surface wiring has been used, remove the

knockout/insert from the bottom of the

timeswitch to accommodate it. Loosen the

two 'captive' retaining screws on the top of

the unit. Now fit the timeswitch to the

Backplate, line the lugs on the timeswitch

with the flanges on the Backplate.

Swing the top of the timeswitch into position

ensuring that the connection blades on the

back of the unit locate into the terminal slots

in the backplate. Tighten the two 'captive' retaining screws to fix the unit securely,

END VIEW OF CHANNELPLUS TIMESWITCH

then switch on the mains supply.

7

INITIAL SETUP Once the mains power has been switched on the ChannelPlus XL, the display will illuminate. The timeswitch has a number of pre-programmed functions to assist the installation which are detailed below; TIME AND DATE - The timeswitch has been pre-set with the current time and date during manufacture. No alteration should be required to the time and date, however if any modification is required, please refer to the `Adjusting Time and date' section of the user guide. PROGRAMME TIMES - The timeswitch has been pre-set with default ON and OFF times, these can be altered to meet the requirements, please refer to the `Setting the Programme Times' section of the user guide.
PLEASE ENSURE THAT THE USER GUIDE IS HANDED OVER TO THE END USER.
8

RESETTING THE CHANNELPLUS XL Electronic equipment can in some circumstances be affected by electrical interference. If the display becomes frozen or scrambled; or if you wish to revert back to the default settings please use the following procedure.
RESET PROCEDURE PLEASE NOTE; Using this procedure will restore the ChannelPlus to the original factory programme settings, the time setting will remain correct.
ADVANCE
BOOST SELECT
Lower the front flap of the unit. On the far right Channel press the ADVANCE (Enter) and SELECT (Blue) buttons together then release the buttons and the programmer will return to the preset factory settings.
9

RESET

General Information Before handing over the installation to the user, always ensure that the system responds correctly on all control programmes and that other electrically operated equipment and controls are correctly adjusted. EXPLAIN HOW TO OPERATE THE CONTROLS AND HAND OVER THE USERS OPERATING INSTRUCTIONS TO THE USER Battery The programmer is fitted with a non-rechargeable, nonserviceable long life battery, which will maintain the programmed time settings with the mains supply disconnected. THIS RESERVE SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the display will be blank.
10

Specification H11XL - H17XL

Electrical Purpose of Control
Contact Rating Contact Type Supply Protection Control Action Operating Time Limitation Software Class Battery Type Battery Life
Display Clock Display Time Adjustment Switch Time Adjustment Programme Selection
Operating Periods per Day Override

Electronic Central Heating Programmer (1 Channel) 3(1) Amp 230V AC Micro-disconnection 230V AC 50Hz only Class II Type 1B,R Intermittent Class A Lithium 10 months continuous operation (minimum) Full Graphical LCD, Backlit 24 Hour / 12 hour AM/PM 1 Minute Intervals 10 Minute Steps Auto, On, All Day, On Constant, Off, Holiday 3 Programme periods Boost 1 or 2 Hours (If pressed during ON Period, will extend ON Period. Instant Advance.

Mechanical Dimensions

163mm x 101mm x 37mm

Case Material

Thermoplastic, flame retardant

Ball Pressure Test Temperature 75C

Mounting

Industry standard 9 pin British Gas Wallplate, independently mounted

Environmental Impulse Voltage Rating Enclosure Protection Pollution Degree
Operating Temperature Range

Cat II 2500V Ip30 Degree 2
0C to +40C

Compliance Design Standard

EN 60730-2-7, BS EN 60730-1 RoHS