User Manual for TARAMPS models including: TW20 Automotive Alarm, TW20, Automotive Alarm, Alarm
Taramps | WARRANTY & REPAIR CENTERS
Taramps | TW20 TR3C G4 ALARM
File Info : application/pdf, 15 Pages, 3.47MB
DocumentDocumentTW20 MANUAL AUTOMOTIVE ALARM 1) Before Starting: ATTENTION: We recommend the complete reading of this manual before proceeding with the installation of this product. · Thisproduct is intended to make it difficult or inhibit the theft/robbery of the vehicle,or objects in it. ·Before contacting TARAMPS technicalsupport,makesure you read thismanual,it contains all the necessary information for installing and using the product. ·The installation of this product must be done by a specialized professional. · During installation, only use a multmeter to measure voltage. ·For perfect functioning, the door and ignition switch signals need to be connected to the alarm. ·Carefully clean the location where the ultrasound sensors and master switchwillbeplaced. ·Fixe a chave master em local secreto e de fácil acesso. 2) Technical Features Supply Voltage 9 to16 Volts Consumption Engine Lock Turning signal Output 6 to17 mA Max. 20 A 2 x 70W c/ digital protection Lock, Unlock, Auxiliary 1 and 2 outputs Max. 200 mA - (Negative Signal) Audio Control and Dedicated Siren Max. 200 mA - (Positive Signal) Programmable output for activating locks and original power windows Universal, Fiat line, VW G5, G6, G7, VW UP andMobi 3) Composition TECHNOLOGY G4 TR2 Control PRESENCE Control TR2-P Manufacturing DEDICATED SUREN RF SIREN Before April 2019 TW20 X X TW20-P TW20 CH TW30 compatible X X X X X CONTROLS TR3C Control TR4C Control Before April 2019 X X X X TR3C Before April 2019 X X X X TR3C TR4C A er June 2019 A er June 2019 A er June 2019 A er June 2019 compatible compatible compatible compatible compatible compatible compatible compatible compatible TW30 CH compatible X X X compatible compatible BASIC ALARM OPERATION: When turning on the alarm by remote control (if the vehicle has audio equipment, windows and power locks properly installed), the audiowill be turned off, the doors will be locked, power windows will be closed, and ultrasound sensors and doors will start to monitor the vehicle. 01 4) Remote Controls* Y Operating Frequency 433.92MHz Y Anti-Cloning Technology (Hopping Code) Y Anti Jammer Transmission System Y 1 3V Battery - CR 2032 LITHIUM Tr2 Control TR2-P PRESENCE CONTROL Replacing the Control Battery. Carefully open the plastic box from the sides.Replace the battery, observing the polarity (+) and (-).Use CR2032 batteries. USE A HIGH QUALITY BATTERY *See item 3 to check which remote control belongs to which Alarm model. Any control model can be purchased separately. ````This equipment operates on a secondary basis, that is, it is not entitled to protection against harmful interference, even from stations of the same type, and may not cause interference to systems operating on a primary basis.'' Images for illustrative purposes only, and may differ from the real image! OFF ON BUTTONS HOME ON OFF AUXILIARY Controls Functions (Manufactured from June 2019) - Anti Jammer function. EXCLUSIVE IN THE G4 TARAMPS LINE. Jammer is when there is another control transmitting near the alarm center,making it impossible to turn the alarm on or off by the registered control. - Code G3 (for theTW20 G1 to G3 line). - Code G4 (exclusive for theTW20 G4 line). Register NEW control in the Alarm Central 3 beeps It is possible to record up to 4 controls, when recording the 5th the first one will be erased. START ++ PROCEDURE: - With the door open, switch on the ignition. DOOR OPEN IGNITION MASTER - Hold the master pressed until beep 3. - When releasing, the alarm will sound1 long beep and the turning signals will be on. Simultaneously press the ON + OFF keys, the alarm will sound 3 Beeps confirming the recording. To exit setup, turn off the ignition. Change code G3 / G4 - TR2 and TR2-P controls A - Hold pressed the Home and Auxiliary keys; B - Release after the LED goes out; C - The LED will flash informing the new code system: 3 flashes= line G1 to G3 4 flashes= G4 line onwards ATTENTION: Function only exists in controls manufactured from June/2019. Change G3 / G4 code - TR3C and TR4C controls A - Hold pressed the Power off and Auxiliary keys; B - Release after the LED goes out; C - The LED will flash informing the new code system: 3 flashes= line G1 to G3 4 flashes= G4 line onwards ATTENTION: Function only exists in controls manufactured from June/2019. 02 5) Remote Control Functions: FUNCTION CONTROL ACTION ALARM RESPONSE 1 - Turn alarm on Press 1 Flash on Turn Signals+ 1 Siren beep3 Beeps indicate Open Door Item 9.1 2 - Turn Alarm off 3 - Turn Alarm on without a beep Press Press then 2 flashes on turn signals + 2 siren beeps Note: 4 flashes on the turn signals+ 4 beeps, indicate that there was a trigger when the alarm was activated. Item 12.1 1 flash on Turn signals 3 Beeps indicate Open Door Item 9.1 4 - Turn Alarm off without a beep 5 - Locate Vehicle Press then 2 flashes on turnsignals Note: 4 flashes on the turn signals, indicate that there was a trigger when the alarm was activated. Item 12.1 Press for 2 seconds with turn signals flash for 20 seconds. To alarm on cancel, press the button 6 - Panic Press alarm on for 2 seconds with Activates the siren and the turn signals flash for 45 seconds. To cancel, press the button 7 -Cancel Alarm Activation 8 - Turning Signals Press with alarm triggered Stops the siren and turn signals. The alarm continues to monitor. Press 2 times ( + ) Turn signals light for 10 seconds.. Item 9.5 9 - Ultrasound Cancel Press then for 2 seconds 1 Long beep, confirms ultrasound cancellation and window close .Ultrasound operates again at next power on. Item 9.6 10 -Auxiliary output, Press for 2 seconds with while the button is pressed, the alarm use auxiliary module the alarm off generates a negative signal. 11 - Auxiliary output 2 use auxiliary module Press for 2 seconds with the alarm off See item 13 12 - Automatic Presence Transmission Press + for 2 seconds See item 7 Only TR2-P control 13 - Range Test Presence function Press + for 2 seconds See item 7.2 Only TR2-P control 14 - HOME Press See item 9.7 03 6) Programming by Master Key With the door open, turn the ignition on and hold the master pressed until the desired function beeps. The alarm will beep with the current setting, to change, press the master the number of times of the desired setting. 1 - ENABLE/DISABLE the alarm 2 - On/Off BEEP 3 - CONTROL RECORDING 4 - AUTOMATIC LOCK 5 - AUTOMATIC REACTIVATION 6 - SELECT WIRED SIREN RINGER 7 - ANTI-THEFT BY PRESENCE 8 - ANTI-THEFT BY SECRET BUTTON 9 - TIME BEFORE LOCKING 3 10 - AUTOMATIC UNLOCK 11 - SIGN FOR LOCK / ORIGINAL WINDOW 1 12 - ULTRASOUND SENSITIVITY ADJUSTMENT 3 13 - BROWN WIRE SETUP see item 13 1 14 - BLACK/YELLOW WIRE SETUP 5 Select Function Configure OFF ON + + START + Example: DOOR OPEN IGNITION MASTER 1x enable 2x disable 1 beep = ENABLE 2 beeps = DISABLE 1 beep = ENABLE 2 beeps = DISABLE See item 4 1 beep = ENABLE 2 beeps = DISABLE item 9.3 1 beep = ENALE 2 beeps = DISABLE item 9.4 Press and release the master until you hear the desired ring. 1 beep = ENABLE 2 beeps = DISABLE item 7 1 beep = ENABLE 2 beeps = DISABLE item 8 1 beep = starts in 1 minuto 2 beeps = starts in 2 minutos 3 beeps = starts in 3 minutos 1 beep = ENABLE 2 beeps = DISABLE 1 beep = UNIVERSAL 2 beeps = VW G5 3 beeps = FIAT item 11 4 beeps = VW G6 G7 5 beeps = VW UP (Lock and Unlock only) 6 beeps = MOBI (config. available in alarms manufactured after 12/2020) To change, see item 12 1 beep = Reads Negative Switch 2 beeps = Reads Positive Switch 3 beeps = Open/close gate 4 beeps = Headlight Signal On/Off 5 beeps = Auxiliary 2 Exclusive functions for theTW30 model 15 - CLONE GATE CONTROL see item 15 16 - TURN ALARM ON BY DISTANCING see item 14 1 beep = Disable 1 2 beeps = Turns alarm on without locking 3 beeps = Turns alarm on and locks 4 beeps = Turn on/lock and turn off/unlock 17 - FACTORY RESET 1 LONG beep FACTORY SETTING RESTORED 3 LONG BEEPS = END OF PROGRAMMING WITHOUT CHANGING SETTING 04 7) Lock Function by Presence/ Distancing Operation: TR2-P Control Required With the ignition on and doors closed, pulling the TR2-P control away from the vehicle automatically activates the distancing lock. After the programmed time (Beep 9 of the configuration by the master), the ultrasound LED starts flashing the audio will be turned off, the siren and turn signals will go off, ther 10 seconds, the engine will start failing until it is definitively blocked.To cancel the lock, bring theTR2-P control closer to the vehicle and wait for the automatic transmission or press the end key. Activate the Presence Function on the TR2-P control - Hold down the Power and Auxiliary keys; - Release after the LED goes out; - The LED will flash informing: 1 flash= Presence Transmission ON 2 flashes= PresenceTransmission OFF Activate Presence Function in the Alarm Central - With the door open, turn the ignition on. Select the Beep 7 function - Hold the master pressed until beep 7. - The alarm will respond informing: 1 Beep = Presence Function ON OFF ON + + START 2 Beeps =Presence Function OFF DOOR OPEN IGNITION MASTER - To change, press 1x (once) to Enable or 2 x (twice) to Disable.After turning off the ignition, the alarm will confirm the new setting with beeps. Configure + 1X Enable 2X Disable Attention: Function canceled from the factory, must be enabled by Beep 7. In G4 alarms it is possible to enable the Presence Functions by Beep 7 and the Lock by Secret Button Beep 8. Set Time for Locking, 1, 2 or 3 minutes - With the door open, turn the ignition on. - Hold the master pressed until beep 9. - The alarm will respond informing: 1 Beep = Lock in 1 Minute 2 Beeps = Lock in 2 Minutes 3 Beeps = Lock in3 Minutes OFF ON Select the Beep 9 function + + START DOOR OPEN IGNITION MASTER Configure + 1X = 1 minute 2X = 2 minutes 3X = 3 minutes + To change, press the Master key the number of times referring to the desired time. Each time you press the Master, the alarm confirms with 1 beep.After turning the ignition off , the alarm will confirm the new setting with beeps. MASTER 7.1) Test Presence Function: Operation: It is not necessary to move the control away from the vehicle, to test the lock, just disable the automatic transmission of the TR2-P control, turn the ignition on , close the doors and wait. Disable the Presence Function on the TR2-P control - Hold the Power and Auxiliary keys pressed; - Release after the LED goes out; - The LED will flash informing: 1 flash= PresenceTransmission ON 2 flashes= PresenceTransmission OFF 05 7.2) Test the automatic transmission range: Operation: It is used to test the automatic transmission range of the Presence function on the TR2-P control.With the automatic transmission of the presence function activated in the control and the function activated in the alarm central, hold the off and auxiliary keys pressed until the LED goes out. After releasing the keys, the LED will flash every 2 seconds, on each flash,the alarm will respond with a BEEP, informing that it has received the transmission. Move the TR2-P control away from the vehicle until the control panel stops responding. To cancel, press any key on the controller. Activate TR2-P control RANGE test - Hold down the Off and Auxiliary keys simultaneously; - Release after the LED goes out; - The LED will flash every 2 seconds: - To cancel, press any key on the controller. Battery Replacement Notice If when the ignition is turned on, the alarm sounds 1 BEEP, it is indicated that the battery voltage of the TR2-P control is low and will need to be replaced as soon as possible. Attention:The Presence Lock function will only be activated with all vehicle doors closed. 8) Lock by Secret Button - required to be enabled by master. Operation: With the ignition on and the doors closed, press the master key for 1 second. Otherwise, Secret Button Lock will be enabled. After the programmed time, (according to the Beep 9 setting), the ultrasound LED starts flashing, the audio will be turned off, the siren and turn signals will go off, 20 secondsafter that ,l the engine will start failing until it is definitively blocked.To cancel the lock, press the master. ATTENTION: In this case, it will not be possible to cancel the triggering by the control. Enable Secret Button Lock Function - With the door open, turn the ignition on. - Hold the master pressed until beep 8. - The alarm will respond informing: 1 Beep = Presence Function ON 2 Beeps =Presence Function OFF OFF ON Select the Beep 8 function + + START DOOR OPEN IGNITION MASTER Configure + 1X Enable 2X Disable To change, press the Master key , 1x once to Enable or 2x twice to Disable. After turning off the ignition, the alarm will confirm the new setting with beeps. 8.1) Valet Function (Secret Button Lock only) It is used to leave the vehicle in a parking lot, for example, without the need to indicate to the driver the location of the Master (Secret Button). Operation: With the door closed, turn off the ignition and hold the Master pressed for 3 seconds. The LED of the ultrasound will flash 3 times confirming activation. OFF ON 3 Seconds + + START To cancel the valet function and return to normal CLOSED operation, switch the ignition on with the door closed and DOOR IGNITION OFF MASTER press the Master for 1 second. 06 Installation Scheme: ATTENTION: The TW20 G4 LINE has a new Ultrasound transmitter. In case the old alarm central is replaced by G4, the transmitter sensor (right side sensor, without LED) must also be replaced by the new one. Master Key 5 - Black 4 - Black According to installation: Open power windows, open the trunk, etc. Requires use of relay 3 - Gray Auxiliary Output 1 2 - Red / Yellow LOCK Dedicated Siren 1 - Black / Yellow 1 - Red +12 Vcc 3 - Black GND 4 - Green / Black turn signal 4 - Green / Black turn signal Auxiliary Output 2 Config. beep 13 1 - Negative switch 2 - Positive Switch 3 - OEpxeclnus/iCvelofusnectiGonaftoer TW20 RF model 4 - Headlight On/Off 5 - Auxiliary Output 2 9 - Brown 10 - Green / Black Output to Power Window Closing Modules 11 - Red / Black UNLOCK 13 - Black 6 - Yellow 7 - Red Fix on the vehicle windshield, 10cm below the roof Left Side Receiver Right Side Transmitter 8 - Green negative door switch Gray ENGINE Gray LOCK MAX 20A Illustrative images 16 - Purple Audio Equipment ACC + audio equipment Max. 200mA 15 - Black / White 14 - Black 12 - Blue Ignition Config. Beep 11 VW mode G6, G7 and UP 07/08 Attention: Function canceled from factory, need to be enabled by Beep 8. In G4 alarms it is possible to simultaneously enable the Beep 8 Secret Button Lock and the Beep 7 Presence Function. Set Time for Locking, 1, 2 or 3 minutes - With the door open, turn the ignition on. - Hold the master pressed until beep 9. - The alarm will respond informing: 1 Beep = Locks in 1 Minute 2 Beeps = Locks in 2 Minutes 3 Beeps = Locks in 3 Minutes OFF ON Select the Beep 9 function + + START DOOR OPEN IGNITION MASTER Configure + 1X = 1 minute 2X = 2 minutes 3X = 3 minutes + To change it, press the Master key the number of times referring to the desired time. Each time you press the Master, the alarm confirms with 1 beep. After turning off the ignition, the alarm will confirm the new setting with beeps. MASTER 9) Alarm Functions: 1 DOOR OPEN WARNING: When turning the alarm on , if 3 BEEPs sound, it indicates that there is an open door. Close it and turn the alarm back on. If it´s not solved, the alarm will cancel the door monitoring. The rest will continue operating normally. If the problem persists, look for a specialized service to repair the door switch. 2 SHUTDOWN - TRIGGERING LIMITER: In case of violation, the alarm will trigger the SIREN and flash the TURN SIGNALS for 45 seconds. 5 seconds later, it will go back to monitoring the sensors. After 4 triggerings by the same sensor, it will be canceled, keeping the others active. It will only be monitored again when the alarm is reset by the remote control. 3 AUTOMATIC LOCK: About 8 seconds after turning the ignition on, the doors will be locked and unlocked by turning the ignition off. It Will not lock if a door is open or if the ignition is turned on before closing the door. It is possible to cancel the unlock when the ignition is turned off, itens 6.4 and 6.10. 4 AUTOMATIC REACTIVATION: Automatically turns the alarm back on after 60 seconds, when turned off by the remote control and: - Door, hood or trunk are not opened; - Ignition is not turned on; - Ultrasonic sensor does not detect movement. It is possible to disable, item 6.5. - Restart function will be canceled, when activating the function turn on remote alarm. 5 TURN SIGNALS: The alarm times the turn signals for 10 seconds. Press the off button on the remote twice, with the alarm off. 6 ULTRASOUND CANCEL: When turning on the alarm canceling the ultrasound, item 5.9, X the power windows will not be closed. To close the windows and activate the ultrasound, turn off and on the alarm using the remote control. 7 HOME function TR2 and TR2-P control: Through the HOME key on the TR2 and TR2-P controls, it is possible to activate the gate operator or residential alarm, without having to use an auxiliary module, only registering the control in the operator's central. The TR2 or TR2-P control must be registered according to the manufacturer's instructions, as if it were a control of the same brand as the gate or residential alarm.Compatible with CODE LEARNING systems. 1039 10) Relay Connections The lock, unlock, auxiliary and audio equipment outputs can handle a maximum of 200mA. If it is necessary to install equipment with a consumption that is higher than 200mA, relays must be used. Transform NEGATIVE alarm signal Transform POSITIVE alarm signal (AUDIO) Transform NEGATIVE alarm signal (200mA) into POSITIVE +12V ( 2 0 0 m A ) i n t o P O S I T I V E (200mA) into NEGATIVE +12V of higher power. of higher power. +12V 30 Alarm Wire 85 87 86 Purple Wire Output +12V Alarm +12V 30 85 86 Battery Negative 87 +ACC Audio equipment 30 Alarm Wire 85 87 Battery Negative 86 +12V Battery Positive Negtive Output 11) VW G6 and G7 Power Window and Door Connections: Function: Closes and opens the power windows, locks and unlocks the doors and opens the trunk. Window activation signal setting = VW G6 / G7, item 11. To open windows, turn off the alarm and hold down the off button on the control. To open the trunk with the alarm off, hold the Auxiliary button pressed. ORIGINAL CENTRAL VW G6 / G7 Located above the fuse box 34 - Brown / Red 3 - Gray 36 - Brown / Red 11 - Red / Black Attention: The trunk opening function will only work in vehicles with original electrical trunk opening system. For its perfect operation, properly ground the alarm module. Some wire colors may change without prior notice from the car manufacturer. It is important to test before making the connections. Signal for window/Electric Lock activation Setup - With the door open, turn the ignition on. - Hold the master pressed until beep 11 .- The alarm will respond informing: 1 Beep = Universal 2 Beeps = VW G5 3 Beeps = FIAT 4 Beeps = VW G6 5 Beeps = VW UP 6 Beeps = MOBI OFF ON Select the Beep 11 function + + START DOOR OPEN IGNITION MASTER Configure + 1X = Universal 2X = VW G5 3X = FIAT 4X = VW G6 5X = VW UP 6X = MOBI + MASTER To change it, press the Master key 4 times, referring to the VW G6/G7 signal. Each time you press the Master, the alarm confirms with 1 beep. After turning the ignition off , the alarm will confirm the new setting with 4 beeps. 10 Window Activation Setup (continuation) Set Signal for window/Electric Lock activation - With the door open, turn the ignition on. - Hold a master pressed until beep 11. - The alarm will respond informing: 1 Beep = Universal 2 Beeps = VW G5 3 Beeps = FIAT 4 Beeps = VW G6 OFF ON Select the Beep 11 function + + START DOOR OPEN IGNITION MASTER 5 Beeps = VW UP 6 Beeps = MOBI Configure + 1X = Universal 2X = VW G5 3X = FIAT 4X = VW G6 5X = VW UP 6X = MOBI + MASTER To change, press the Master key the number of times referring to the desired setting. Each time you press the Master ,the alarm confirms with 1 beep. After turning the ignition off, the alarm will confirm the new setting with beeps. 11.1 Universal Mode : Negative signal 15 seconds. 11.2VW G5 Mode: Gol, Saveiro, Voyage generation 5) Manufactured after February 2009, with original window and power lock. Close the windows, lock and unlock the doors. Connect the Green/Black alarm wire to pin 5 of the original panel 23-way connector, located above the accelerator pedal. DO NOT connect Red / Black and Red / Yellow (lock and unlock) wires. 11.3 FIAT Mode: Palio, Idea, Punto and Linea with automated power windows, closeand open.Connect the Green / Black alarm wire to pin 8 on the original central , to the Palio and Idea line located behind the glove compartment.On Linea and Punto, Red / Black wire in the central located behind the fuse box. 11.4 VW G6 and G7 mode: Gol, Saveiro, Voyage generation 6 and7), with original power windows. Connect the Red / Black alarm wire to the Brown / Red wire, pin 36, from the original central located above the fuse box. Functions: lock, unlock, close and open the windows. To open the windows, hold the control off button pressed with the alarm off. To open the Trunk, connect the Gray wire from the alarm to the Brown / Red wire, pin 34 from the original central located above the fuse box. NO RESISTOR NEEDED. 11.5VW UP: Only LOCK and UNLOCK. Connect the Red / Black alarm wire to the Brown / Green wire located on the left column of the vehicle. 11.6 MOBI: New Uno after 2015, MOBI and ARGO, with original power windows.Connect the Green / Black alarm wire to the Brown / Green wire of the original alarm 6-way harness located on the steering column. 11 12) G2 Ultrasound Sensors Attach the sensors to the vehicle's windshield, 10 cm below the roof. Ultrasound sensors come with digital sensitivity adjustment. Change the default setting only if necessary. The table follows below: Click 1 Once 2 Twice 3 Times 4 Times 5 Times Sensor Sensitivity +20% +10% Increase Factory standard Decrease -10% -20% Alarm Response 1 Beep 2 Beeps 3 Beeps 4 Beeps 5 Beeps Set Ultrasound Sensitivity: - With the door open, turn the ignition on. - Hold the master pressed until beep 12. --The alarm will respond informing the current setting. 1 Beep = Sensitivity+20% Select Beep 12 function 2 Beeps = Sensitivity+10% 3 Beeps = Sensitivity Standard 4 Beeps = Sensitivity-10% OFF ON + + START 5 Beeps = Sensitivity-20% DOOR OPEN IGNITION MASTER Configure + 1X = +20% 2X = +10% 3X = Standard 4X = -10% 5X = -20% + To change, press the Master key the number of times referring to the desired sensitivity. Each time you press the Master ,the alarm confirms with 1 beep. After turning the ignition off, the alarm will confirm the new MASTER setting with beeps. 12.1) LED FUNCTIONS: LED OFF - Alarm off; LED FLASHING NORMALLY - Alarm on; LED ALWAYS ON - Door, Hood or Trunk open; LED FLASHES 2X - Alarm on, with cancelled ultrasound sensor; LED FLASHING AFTER TURNING OFF ALARM BY REMOTE CONTROL - Indicates which sensor caused the last trigger: - 1 flash - ignition. - 2 consecutive flashes - ultrasound sensor. - 3 flashes in a sequence- doors, hood or trunk. 12 Auxiliary Output 2 Setup- brown wire Programming by Master - With the door open, turn the ignition on. - Hold the master pressed until beep 13. - The alarm responds by informing the current setting: Select the Beep 13 function 1 Beep = Reads negative switch 2 Beeps = Lê interruptor Positivo 3 Beeps = OpExecnlu/sCivloesfeunAcutitoonmfoartethdeGTaWte30 model 4 Beeps = Reads Headlight On/Off OFF ON + + START DOOR OPEN IGNITION MASTER 5 Beeps = Auxiliary Output 2 Configure + 1X = Door - 2X = Door + 3X = Gate 4X = Headlight 5X = Auxiliary 2 + To change, press the Master key the number of times referring to the desired function. Each time you press the Master, the alarm confirms with 1 beep. After MASTER turning the ignition off , the alarm will confirm the new setting with beeps. 1) Reads Negative switch. To install on a door switch, hood or trunk with a Negative signal, when open. 2)Reads Positive switch. To install on door switch, hood or trunk with Positive signal ,when open. 3) Open / Close Automated Gate. Exclusive function for the TW30 model 4) HeadlightWarning On/Off. After 10 seconds with the ignition on, the ultrasound LED will be flashing, warning that the headlight is off, turning on the headlight ,the LED goes out. When turning the ignition off and opening the door with the headlight on, the alarm sounds a long beep. 5) Auxiliary Output 2 It is used to lower electric windows for example. Using an Auxiliary Relay is required. Activate Auxiliary Outputs 2 - Press and hold the OFF key on the control with the ignition off and the alarm off. + than 3 seconds 13 14) Turn Alarm on by Distancing This function is used to turn on the alarm only when pulling the TR2-P G4 remote control away from the vehicle. After turning the ignition off, opening and closing the vehicle door, and moving the control beyond the transmission range, within 15 seconds the alarm will turn on. According to the setting, the alarm will: 1st Beep = Disabled, the alarm will only turn on/off when pressing the control buttons. 2nd Beep = Turns the alarm on when moving the control away without locking the doors, it will only turn off the alarm when pressing the control Off button. 3rd Beep = Turns on the alarm when moving the control away and locks the doors, it will only turn off the alarm and unlock the doors when pressing the control's Off button. 4th Beep = Turns on the alarm when moving the control away and locks the doors. Turns off the alarm and unlocks the doors by pressing the control's Off button or by bringing the TR2-P G4 control closer to the vehicle and waiting for the automatic transmission. ATTENTION: EXCLUSIVE function of the G4 line with TR2-P G4 control. Programming by Master - With the door open, turn on the ignition. - Hold the master pressed until beep 16. Select the Beep 16 function - The alarm responds with the current setting: 1 Beep = Disabled 2 Beeps =Turns on the alarm without locking 3 Beeps = Turns on the alarm and lock OFF ON + + START DOOR OPEN IGNITION MASTER 4 Beeps = Turn On and Lock / Turn Off and Unlock Configure + 1X = Disable 2X = on without Lock 3X = On and lock 4X = On and lock Off and lock + To change, press the Master key the number of times referring to the desired function. Each time you press the Master, the alarm confirms with 1 beep. After turning the ignition,off the alarm will confirm the new setting with beeps. MASTER WARRANTY TERM TARAMPS, located at Rua Abílio Daguano, 274 Res. Manoel Martins - Alfredo Marcondes - SP, ZIP19.180-000, guarantees this product against design, manufacturing, assembly and/or joint and several defects due to design flaws tha make t it unsuitable or inappropriate for its intended use, for a period of 24 months from the date of purchase.In the event of a malfunction within the warranty period,TARAMPS' liability is limited to repairing or replacing the device manufactured by it. This warranty excludes: · Products damaged by incorrect installation, water infiltration, tampering by unauthorized persons; · Natural wear components: such as battery; · Scratched or torn warranty seal; · Cases where the product is not used under normal conditions; · Defects caused by accessories, modifications or equipment attached to the product; · The product presents damage resulting from drops, impacts or the action of agents of nature (floods, lightning, etc.); · Costs for removing and reinstalling the equipment, as well as transporting it to the technical assistance post; · Damage of any kind, resulting from problems with the product, as well as losses caused by interruption of use. Factory technical assistance department: Taramps Electronics - Rua: Abílio Daguano, nº 274 - ZIP19.180-000 Fones: +55(18) 3266-4050 / 99749-3391 E-mail: service@taramps.com.br Taramps reserves the right to change the contents of this manual without prior notice or obligation to apply the modifications to previously produced units. 14 Fabricado por / Manufactured by: TARAMPS ELECTRONICS LTDA CNPJ / TAX ID: 11.273.485/0001-03 R. João Silvério, 121· Res. Manoel Martins Alfredo Marcondes - SP Indústria Brasileira - Made in Brazil MN_015377_R03