Ecler PAGENETDN Digital Paging Station & Touchscreen Control Panel

User Manual

Important Information

1. Important Notice

The lightning flash within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" inside the device that may be of sufficient magnitude to cause electric shock.

The exclamation mark within an equilateral triangle is intended to alert the user to important operation and maintenance instructions that must be followed.

WARNING (if applicable): Connections marked with the "⚡" symbol may be live, carrying voltage high enough to constitute an electric shock hazard. External wiring to these connections must be done by qualified personnel, otherwise, the use of pre-assembled leads is recommended.

CAUTION: To prevent fire or electric shock, this device must always be protected from moisture.

CAUTION: Class I safety devices must only be connected to earthed mains sockets.

2. Important Safety Instructions

  1. Read this user manual carefully.
  2. Keep this user manual in a safe place.
  3. Observe all warnings contained herein.
  4. Follow all instructions contained herein.
  5. Never use the device near water.
  6. Always clean the device with a dry cloth.
  7. Keep ventilation openings clear at all times and install the device according to the manufacturer's instructions.
  8. Do not install the device near heat sources such as radiators, stoves, or other heat-generating equipment (including amplifiers).
  9. Never disable the protective function of a polarized or grounded plug. A polarized plug has two contacts of different widths. A grounded plug has two pins and a ground contact. The wider contact or the third contact serves your safety. If the supplied plug does not fit the socket, have it replaced by a qualified electrician.
  10. Ensure that the power cord cannot be stepped on or pinched, especially near the plugs, connection sockets, and where the cord exits the device.
  11. Use only accessories recommended by the manufacturer.
  12. Disconnect the device from the mains during thunderstorms or when it will not be used for extended periods.
  13. Only have servicing performed by qualified personnel. Servicing is required when the device has been damaged in any way, e.g., if the power cord or plug is damaged, if liquids have been spilled into the device, if objects have entered the device, if the device has been exposed to water or moisture, if it does not function normally, or if it has been dropped.
  14. Disconnecting from the mains: By switching off the device using the POWER switch, all functions and indicator lights of the device are interrupted. However, to completely disconnect the device from the mains, the power cord must be pulled from the socket. Therefore, the power plug should always be easily accessible.
  15. The device is connected to a grounded socket using a power cord.
  16. The specifications are located on the underside of the device.
  17. Protect the device from splashes and do not place any containers filled with liquids (e.g., vases) on it.
  18. This product is intended for indoor use only.

CAUTION: This product must not be disposed of as normal household waste under any circumstances. Please dispose of it at the nearest collection point for electrical and electronic waste.

NEEC AUDIO BARCELONA, S.L. disclaims any responsibility for damage to persons, animals, or objects resulting from failure to comply with the above warnings.

Introduction

3. Important Notice

Thank you for your trust in choosing our DANTE™/AES67 Paging Station PAGENETDN with digital EclerNet control unit. To make the most of the device's capabilities and achieve the best possible performance, it is VERY IMPORTANT that you carefully read and fully understand the contents of this user manual before making any connections.

To ensure optimal functionality of the device, we strongly recommend having all maintenance work performed by our authorized customer service.

All ECLER products come with a warranty. The validity period and conditions can be found at www.ecler.com or on the warranty card included with the device.

4. Introduction

PAGENETDN is a programmable paging station with two audio outputs: DANTE™/AES67 (digital) and analog (balanced). This allows the device's control functions and microphone signal to be used for paging in conjunction with any EclerNet Matrix, whether it supports DANTE™/AES67 or not: MIMO4040DN, MIMO88, MIMO88SG, and MIMO1212SG.

At the same time, PAGENETDN has the same control functions as the WPNETTOUCH model and can be programmed to control one or more networked EclerNet devices; it can even control a complete installation, i.e., a project where a variety of EclerNet devices work together: digital matrices MIMO4040DN, MIMO88, MIMO88SG, MIMO1212SG, digital audio managers (multifunction amplifiers) of the NXA series, DUO-NET PLAYER, etc. The device is fully programmable via the EclerNet Manager application (*).

(*) For more information, please refer to the EclerNet Manager application manual. The EclerNet Manager application is available for download at www.ecler.com.

The device is supplied as a desktop console, with a gooseneck microphone and a 10" capacitive touchscreen control panel for displaying and managing UCPs for paging functions and for controlling networked EclerNet devices, VEO video devices, and also third-party devices.

Key Features

4.1. Key Features

Installation and Connections

5. Installation and Connections

5.1. Installation and Cabling

The microphone is included with the device and must be installed in the PAGENETDN console before use.

To do this, carefully insert the microphone into the XLR connector of the console, paying attention to the correct alignment of the connection pins (the Ecler logo on the microphone must be aligned with the back of the device), and push until it clicks. The click indicates that the safety latch of the XLR connector has engaged. Once connected, the microphone is securely attached to the console and can hardly move vertically, ensuring quiet operation and giving the user a sense of high durability.

If it is necessary to remove the microphone from the console, a "Pin" type removal tool must be used. Insert this tool with pressure into the opening on the back of the microphone socket on the console surface. This will release the XLR safety latch, allowing you to pull the microphone out with a firm tug.

Before you can program and use the PAGENETDN, it must be connected to a network via its internal RJ45 ETHERNET interface. This and all other connections can be accessed by unscrewing the lower metal plate of the device (3 screws must be removed).

[Diagram showing internal connections: External PSU Connector, Ethernet Interface, Phantom Power On/Off, HPF On/Off, Aux In L/R, Mic In Gain, Aux In Gain]

The device must then be supplied with DC voltage, either directly via PoE (Power over Ethernet), if available through the Ethernet switch to which the device is connected, or via the supplied external 12V DC 2A power supply (EXTERNAL PSU CONNECTOR).

Additionally, there are 2 more audio connections available:

5.2. Audio Settings

The PAGENETDN model features various audio controls in its electronics for adjusting incoming analog audio signals:

(*) Note: The XLR microphone connector is suitable for standard XLR microphones like the Ecler eMCN1 included in the delivery, but it cannot accommodate microphones whose base is thicker than the standard XLR size.

[Image showing two microphone connectors, one with a red cross indicating incompatibility]

Operation

6. Operation

The PAGENETDN console must be carefully integrated into an EclerNet project and correctly configured (regarding DANTE™/AES67 audio routing and/or control functions) so that the UCP paging and control panels available to the end-user are ultimately displayed. Examples:

[Image of a "MIMO4040DN MAIN PAGER" interface with numbered buttons]

[Image of a "SECONDARY PAGER" interface with numbered buttons]

[Image of a "DRESSING ROOMS" interface with volume controls and media player options]

For more information, please refer to the EclerNet Manager application manual, Chapter PAGENETDN DEVICE.

Local Device Configuration

7. Local Device Configuration

You can access the PAGENETDN settings and configuration menus directly via the device's touchscreen. These menus are identical to those of the WPNETTOUCH control panel, as a WPNETTOUCH is integrated into the PAGENETDN console.

The same settings can also be accessed remotely when the device is controlled from a remote computer running the EclerNet Manager application.

Local access to the configuration menus is achieved by clicking the SETUP icon on the device's start screen:

[Image of the device's start screen showing "User Control Panels" with different UCPs like "UDP/TCP Control", "M4040DN Paging", "Paging consoles", "CONF_ROOM", and navigation arrows]

The following configuration menus are available:

Setup | Information/Tools

7.1. Configuration Menu for the Display

[Image of the "Screen Configuration" menu with options for Display Mode, Backlight Intensity, Auto-Zoom Panels, Show Panel OSD Buttons, Scroll by OSD Buttons, Scroll by Swipe]

This menu allows you to adjust various parameters that affect the displayed elements and the device's display controls:

[Image showing a "PRESET SELECTOR" interface with navigation buttons and a toolbar]

Note: Even if these buttons are not visible, they may still be active, so pressing the top corners activates horizontal scrolling through the panel pages, and pressing the bottom corners displays the toolbar. This aspect must be considered when designing individual UCP pages regarding the placement of controls (buttons, sliders, knobs, etc.). The top corners should remain as clear as possible if the OSD buttons are to be used for scrolling between pages, and the bottom corners (toolbar display) must always remain clear.

The toolbar displays new access to horizontal scrolling through panel pages (left and right), access to the device's home screen ( "HOME" icon), and the icon to exit the toolbar ("X"):

[Image showing the toolbar with "HOME" and "X" icons, and page navigation information]

7.2. Configuration Menu for the Device

[Image of the "Device Configuration" menu with fields for Device Name, Device Password, and Enable UCP Server]

This menu allows you to set the following device parameters:

Note: When disabled, another device or PC running a project that includes all or some of the hardware components present in the WPNETTOUCH's local project could take control of these hardware components. Only one device/project can control a hardware element at a time, meaning that before attempting to control hardware elements from another device, they must each be released:

7.3. Network Configuration Menu

[Image of the "Network Configuration" menu with fields for IP Address, Network Mask, and Gateway, along with a numerical keypad]

In this menu, the following network connection parameters of the WPNETTOUCH can be changed: IP address, network mask, and gateway.

Note: Neither the WPNETTOUCH nor any other EclerNet device supports the IP address dynamic assignment protocol (Dynamic Host Configuration Protocol or DHCP), so a manual assignment of static addresses is always required.

7.3.1 Factory Default Network Parameters

The factory default network settings for compatible devices with EclerNet Manager are as follows:

7.4. "Information / Tools" Menu

[Image of the "Information / Tools" menu showing Server IP Address, Server Project, Local IP Address, Local Project, Available Storage, Ethernet Address, Display Resolution, Firmware version, and buttons for Project Defaults, Factory Defaults, Reboot]

This menu displays the following information:

The following Restore/Reboot options are also available:

Connecting to a UCP Server

8. Connecting to a UCP Server

From the device's start screen, you can access the connection screen by clicking the connection icon in the top right corner:

[Image of the "User Control Panels" screen with navigation arrows and a settings icon]

[Image of the "Connect to..." screen with a server address input field and a keyboard]

On this page, you can select the UCP server to which the device should connect as a client. A UCP server can be a computer or a matrix MIMO4040DN (in fact, it has a UCP server integrated into its processor!), another WPNETTOUCH / WPmSCREEN, or even the PAGENETDN / WPNETTOUCH itself. In any case, the UCP server hosts an EclerNet Manager project and executes it, and this project contains a series of UCPs that can be controlled remotely by any UCP client.

The IP address of the server device can be entered directly using the keyboard displayed on the screen, or you can select it from a list of possible, automatically detected server devices. Access to this list is made by clicking the gray button with the list icon to the right of the "Connect to..." button:

[Image of the "Server list" showing detected servers and scroll arrows]

Note: On the list of detected server devices, the name of the WPNETTOUCH device under control appears in green (the device that matches the local IP address).

After selecting a server device or IP address, the selection is confirmed by clicking the "Connect to..." button, and the connection to the server is established. Upon successful connection, the UCPs provided by the server to the WPNETTOUCH client are displayed on the screen:

[Image of the "User Control Panels" screen connected to a specific server]

Scope of Delivery

9. Scope of Delivery

Function List

10. Function List

  1. Multi-Touchscreen
  2. Gooseneck microphone
  3. XLR connector
  4. Power connector

Functional Diagram

11. Functional Diagram

[Diagram showing the PAGENETDN unit with numbered components: 1. Touchscreen, 2. Microphone, 3. Microphone connector, 4. Base]

Block Diagram

12. Block Diagram

[Block diagram illustrating the internal signal flow of the PAGENETDN, including MIC input, LINE input, DANTE™/AES67 interface, touchscreen, power supply, and Ethernet connection]

Technical Data

13. Technical Data

MIC INPUT
Microphone typeRemovable gooseneck condenser microphone (eMCN1)
Polar patternUnidirectional
Microphone freq. response50Hz – 18kHz (-10dB)
Phantom Voltage48VDC, ON/OFF by internal JUMPER
Output level with eMCN1 MICROPHONE-5dBV @ 94dB SPL with ADJ MAX.
-10dBV @ 94dB SPL with ADJ MID.
-20dBV @ 94dB SPL with ADJ MIN.
HPF100Hz 12dB/oct ON/OFF by internal JUMPER
LINE INPUT
ConnectorRCA
SignalLine level, L + R
Nominal input level-10dBV
Gain adjust-20dBV / 0dBV
Input impedance>10kΩ
DANTE™/AES67 AUDIO INTERFACE
DANTE™/AES67 Network Tx channels2 (2 flows)
Latency1 / 2 / 5 ms (selectable)
ConnectorRJ45
AUDIO OUTPUTS
Microphone output signal ConnectorBalanced, analog
Output levelPhoenix connector (symmetric) 0dBV
System
CPURK3128 quad core processor, clocked 1.6G
RAM1GB
ROM8GB
Screen
Size10.1" IPS
Resolution1280x800
Contrast ratio1300:1
Brightness300cd/m²
Screen scale / Display area16:9 / 218x135mm
BacklightLED
Touch-panelCapacitive multi-touch
Network & Connectivity
EthernetSupports PoE
Ethernet portEthernet Base-Tx 10/100Mb / 1GB CAT5e or better up to 100m.
Power
External power supply voltage12VDC
Maximum power consumption12W from 12V External Power Supply Voltage
15W from PoE
PoEclass 0 802.3af Poe PD compliant
Mains Voltage100-240VAC + External PSU 12VDC
General

Dimensions (microphone excluded (WxHxD)) 295x155x135 mm / 11.6"x6.1"x5.3"

Weight: 1.5 kg / 3.3 lbs

AC Power Adapter: 100-240VAC 47-63Hz 12V / 2A, multiplug

Accessories included:

General Information

Due to production tolerances, all specifications are subject to change. NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements to the design or manufacturing that may affect these product specifications.

For technical questions, please contact your supplier, dealer, or fill out the contact form on our website under Support / Technical requests.

Motors, 166-168, 08038 Barcelona - Spain - (+34) 932238403 | information@ecler.com | www.ecler.com

PDF preview unavailable. Download the PDF instead.

1752687462-ecler-pagenetdn-user-manual-de a.caviedes Adobe PDF Library 25.1.51

Related Documents

PreviewEcler PAGENETDN Digital Controller User Manual
User manual for the Ecler PAGENETDN digital controller, a paging station with a touchscreen for EclerNet control, featuring Dante™/AES67 audio transport.
PreviewEcler PAGENETDN: Digitale Paging-Station und Touchscreen-Bedienpanel Bedienungsanleitung
Umfassende Bedienungsanleitung für die Ecler PAGENETDN, eine digitale Paging-Station und ein Touchscreen-Bedienpanel mit DANTE™/AES67-Integration und EclerNet-Steuerung. Erfahren Sie mehr über Installation, Konfiguration und Betrieb.
PreviewEcler PAGENETDN Technical Data Sheet
Technical specifications and features of the Ecler PAGENETDN programmable paging station with dual audio output (DANTE/AES67 and analog).
PreviewEcler PAGENETDN Digital Panel User Manual
User manual for the Ecler PAGENETDN digital paging panel, detailing its features, installation, configuration, and operation. Covers Dante/AES67 audio interface, microphone input, line input, and network connectivity.
PreviewEcler PAGENETDN: Technical Data Sheet for Dante/AES67 Paging Station
Detailed technical specifications and features of the Ecler PAGENETDN, a programmable paging station with Dante/AES67 audio output, 10-inch touch screen, and EclerNet control capabilities for commercial and hospitality environments.
PreviewEcler PAGENETDN: Manuel d'utilisation pour le Contrôleur Numérique
Guide complet pour l'installation, la configuration et l'utilisation du contrôleur numérique Ecler PAGENETDN, incluant des instructions de sécurité et des spécifications techniques.
PreviewEcler PAGENETDN Dante/AES67 Paging Station User Manual
Comprehensive user manual for the Ecler PAGENETDN, a digital paging station and control touch-screen with Dante/AES67 audio capabilities. It covers installation, configuration, operation, technical specifications, and troubleshooting.
PreviewEclerNet Manager User Manual
User manual for EclerNet Manager software, detailing its features for configuring and managing Ecler digital audio systems, including devices like MIMO matrixes and NPA/NZA/NXA amplifiers.