Elitech RC-4/RC-4HA/RC-4HC Quick Start Guide

Brand: Elitech

Install Battery

  1. Use a proper tool, such as a coin, to loosen the battery cover.
  2. Install the battery with the "+" side upward, ensuring it is under the metal connector. The battery type is CR2450.
  3. Replace the cover and tighten it.

Note: Do not remove the battery while the logger is running. Please change it when necessary.

Install Software

  1. Visit www.elitechus.com/download/software or www.elitechonline.co.uk/software to download the software.
  2. Double-click the downloaded zip file and follow the on-screen prompts to install.
  3. Once installation is complete, the ElitechLog software will be ready for use.

If necessary, disable your firewall or close your antivirus software.

Start/Stop Logger

  1. Connect the logger to a computer to synchronize its time or configure parameters as needed.
  2. Press and hold the button to start the logger until a [running indicator] appears. The logger will then begin recording.
  3. Press and release the button to cycle through different display interfaces.
  4. Press and hold the button to stop the logger until a [stop indicator] appears. The logger will cease recording.

Note: All recorded data is protected for security reasons and cannot be altered.

Configure Software

The ElitechLog software facilitates several operations:

  • Download Data: The software automatically accesses the logger and downloads recorded data to your computer when connected. If not, manually click "Download Data".
  • Filter Data: Under the "Graph" tab, click "Filter Data" to select and view data within a specific time range.
  • Export Data: Click "Export Data" to save your data in Excel or PDF format.
  • Configure Options: Set logger time, log interval, start delay, high/low limits, date/time format, email alerts, and more. Refer to the User Manual for default parameters.

Important Note: Applying new configurations will reset any previously recorded data. Ensure all necessary data is backed up before applying new settings.

For more advanced functions, refer to the "Help" section within the software. Additional product information is available on the company website: www.elitechlog.com.

Troubleshooting

If...Please...
Only a few data points were logged.Check whether the battery is installed correctly.
The logger does not log after startup.Check whether the start delay is enabled in the software configuration.
The logger cannot stop logging.Check parameter settings to see if button customization is enabled (default configuration is disabled).
Models: Temperature Data Logger, RC-4, RC-4HA, RC-4HC

PDF preview unavailable. Download the PDF instead.

B1BwTwP6-oS Adobe PDF library 10.01

Related Documents

PreviewElitech RC-4 / RC-4HC User Manual
User manual for the Elitech RC-4 and RC-4HC temperature and humidity data loggers. Includes specifications, operation, status indication, and battery replacement.
PreviewElitech IoT & Cold Chain Data Loggers | Comprehensive Product Catalog
Explore Elitech's extensive range of IoT and cold chain data loggers, including temperature, humidity, and multi-use devices. Discover features, technical specifications, and software solutions for reliable monitoring and compliance.
PreviewElitech RC-5+ Temperature Data Logger: User Manual and Specifications
This manual provides detailed instructions for using the Elitech RC-5+ USB temperature data logger, covering setup, operation, data download, and analysis with Elitech software. Features and technical specifications are also included.
PreviewElitech RC-61/GSP-6 Temperature and Humidity Data Logger User Manual
Comprehensive user manual for the Elitech RC-61/GSP-6 temperature and humidity data logger. Learn about its features, specifications, operation, status indications, battery replacement, and default parameters.
PreviewElitech RC-5 Quick Start Guide: Temperature Data Logger
Quick start guide for the Elitech RC-5 temperature data logger, covering battery installation, software setup, logger operation, technical specifications, and troubleshooting.
PreviewElitech RC-51/RC-51H Reusable Temperature Data Loggers - Product Overview
Elitech's 2016 brochure details the RC-51 and RC-51H reusable temperature data loggers, essential for monitoring in medicine, food, life science, and logistics. Features include defrost functions, alarms, and manual power control for reliable temperature management.
PreviewElitech GSP-6/GSP-6G/RC-51/RC-51H Temperature and Humidity Data Logger Certificate of Compliance
Official Certificate of Compliance for Elitech GSP-6, GSP-6G, RC-51, and RC-51H Temperature and Humidity Data Loggers, issued by Ente Certificazione Macchine Srl, verifying compliance with EN 12830:2018.
PreviewElitech RC-61/GSP-6 User Manual: Temperature and Humidity Data Logger
This user manual provides comprehensive guidance for the Elitech RC-61/GSP-6 temperature and humidity data logger, covering its features, specifications, operation, and important usage notes for cold chain monitoring applications.