Lockin Veno Palm Vein Recognition Smart Lock

Quick Start Guide

Product Overview

This document provides a quick start guide for the Lockin Veno Palm Vein Recognition Smart Lock. It covers the exterior and interior assembly, parts list, installation preparation, and settings.

Exterior Assembly

The exterior assembly includes:

Interior Assembly

The interior assembly includes:

Parts List

Installation Preparation

Verify Door Requirements

Ensure your door meets the following requirements:

Diagram Description: A diagram shows a door edge with measurements for cross bore diameter, backset distance, and minimum distance between handle and door hole center. It also indicates the door hole diameter.

Install the Deadbolt

  1. Determine if the deadbolt length needs adjustment.
  2. Insert the lock body into the edge bore of the door. Ensure the word "TOP" is oriented upwards and the T-shaped slot for the tailpiece is centered in the face hole.
  3. Diagram Description: Shows inserting the lock body into the door edge.
  4. If the backset is 2³⁄₈ in / 60 mm, insert the lock body directly.
  5. If the backset is 2³⁄₄ in / 70 mm, adjust the deadbolt length by rotating it 180°.
  6. Diagram Description: Illustrates adjusting the deadbolt length.
  7. Ensure the "TOP" is oriented upwards.
  8. Insert the door status cable terminal into the side hole of the door and retrieve it from the inside to straighten it. Be careful not to damage the cable and terminal.
  9. Diagram Description: Shows routing the door status cable.
  10. Ensure the door status cable passes through the space under the deadbolt and into the interior of the door.

Install the Exterior Assembly

  1. Measure the cross bore diameter. Install the exterior assembly directly if the diameter is 2¹⁄₈ in / 54 mm.
  2. Diagram Description: Shows measuring the cross bore diameter and installing the exterior assembly.
  3. Ensure the exterior assembly is securely fixed vertically. It is recommended to have assistance for this step.
  4. Diagram Description: Illustrates securing the exterior assembly vertically.
  5. Ensure the cable passes under the deadbolt.

Install the Interior Mounting Plate

  1. Detach the interior mounting plate and battery cover from the interior assembly.
  2. Diagram Description: Shows detaching the mounting plate and battery cover.
  3. Pass the cables through the mounting plate slot.
  4. Align the mounting plate with the threaded screw.
  5. Diagram Description: Shows passing cables and aligning the mounting plate.
  6. IMPORTANT: Use the correct screws. Using incorrect screws may lead to installation failure or damage to the lock.
  7. Route the door status cable through the cable hole of the mounting plate.
  8. Route the power cable and Wi-Fi cable over the door status cable through the designated hole on the mounting plate.
  9. Diagram Description: Shows routing all cables through the mounting plate.
  10. Carefully straighten the door status cable to avoid damage.
  11. Align and insert the screws, ensuring the cable is positioned below without being pinched.
  12. Manually align the screws with the nuts through the guide holes of the lock body and tighten them with a screwdriver.
  13. Diagram Description: Illustrates aligning and tightening the screws.
  14. For easier installation, ask someone to hold the exterior assembly to ensure it is securely fixed and does not tilt.
  15. Diagram Description: Shows a person holding the exterior assembly.
  16. Use a screwdriver to fix your screws.

Install the Interior Assembly

  1. Connect the power cable, door status cable, and Wi-Fi cable to the ports on the interior assembly.
  2. Diagram Description: Shows connecting the cables to the interior assembly.
  3. Follow the steps: Connect the door status cable to port 1, the Wi-Fi cable to port 2, and the power cable to port 3.
  4. Diagram Description: Close-up of cable connections with port numbers.
  5. IMPORTANT: Ensure the power cable is connected correctly. To disconnect the Wi-Fi cable, gently pull the handle.
  6. Insert the bit into the T-shaped slot of the interior assembly.
  7. Ensure the cables are neatly arranged in the designated space on the interior assembly.
  8. Diagram Description: Shows inserting the bit and arranging cables.
  9. Ensure the deadbolt is retracted and set the thumb turn to the vertical position.
  10. Secure the interior assembly tightly to the door panel and tighten it with the interior assembly screws.
  11. Diagram Description: Shows securing the interior assembly.
  12. Check if the bolt can extend and retract smoothly by turning the thumb turn without obstruction.
  13. Diagram Description: Shows testing the bolt operation.

Install the Strike Plate and Strike Box

Ensure the depth of the bolt hole on the door frame for the strike plate installation is at least 1 inch. Otherwise, the initial calibration process after installation may fail, leading to malfunction during future use.

Settings

  1. Download the Lockin Smart app and log in or create an account.
  2. Search for "Lockin Smart" in the Apple App Store or Google Play Store.
  3. Diagram Description: Shows app store icons for Apple and Google Play.
  4. In the Lockin Smart app, tap "Add Device". On the displayed page, tap "Veno". Follow the app's instructions and configuration steps to complete the settings.
  5. Diagram Description: Screenshot of the Lockin Smart app showing the "Add Device" option.
  6. Once the settings are complete and the battery cover is closed, the Veno Smart Lock is ready to use.

Specifications

Customer Service and Warranty

Contact Us

LOCKIN (U.S.) INC. All rights reserved, registered in the United States and other countries.

FCC Compliance Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

ISED Compliance Statement

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.

L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) L'appareil ne doit pas produire de brouillage; (2) L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

ISED Radiation Exposure Statement

This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.

Cet équipement est conforme aux limites d'exposition aux radiations IC CNR-102 établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps.

Restrictions Information

The devices certified under this annex are not permitted to be used on satellites. Devices used on aircraft are permitted under the following conditions:

For ICES

CAN ICES-003(B) / NMB-003(B)

Warning

PDF preview unavailable. Download the PDF instead.

Veno Guide de Demarrage Rapide Francais ?v=1750908444 Adobe PDF library 17.00 Adobe Illustrator 29.1 (Windows)

Related Documents

PreviewLockin Veno Palm Vein Recognition Smart Lock Quick Start Guide
A quick start guide for the Lockin Veno Palm Vein Recognition Smart Lock, covering installation, setup, and specifications.
PreviewDéclaration de conformité de LOCKIN (U.S.) INC. pour le modèle LKMSD551
Déclaration de conformité de LOCKIN (U.S.) INC. pour le modèle LKMSD551, certifiant la conformité avec les règles de la FCC et les exigences techniques applicables.
PreviewLockin Veno Palm Vein Recognition Smart Lock Quick Start Guide
A quick start guide for the Lockin Veno Palm Vein Recognition Smart Lock, model LKMSD411A, detailing its features, installation, and setup.
PreviewLOCKIN Veno Plus Smart Lock Installation and User Guide
Comprehensive guide for installing and using the LOCKIN Veno Plus Smart Lock, featuring palm vein recognition. Includes setup instructions, parts list, and technical specifications.
PreviewLockin Veno Plus Palm Vein Recognition Video Smart Lock Quick Start Guide
A comprehensive quick start guide for the Lockin Veno Plus Palm Vein Recognition Video Smart Lock, model LKMSD551. This guide covers product features, exterior and interior assembly, installation steps, setting up the Lockin Smart app, and compliance information.
PreviewExternal Photos of LOCKIN LKMSD551 Smart Lock
This document contains external photographs of the LOCKIN LKMSD551 smart lock, identified by FCC ID 2BMOG-LKMSD551. The photos showcase the device's construction and components.
PreviewLockin Veno FAQ & Troubleshooting Guide
Comprehensive Frequently Asked Questions and troubleshooting solutions for the Lockin Veno smart lock, covering installation, features, connectivity, and maintenance.
PreviewLockin Veno Pro FAQ & Troubleshooting Guide
Comprehensive guide to Lockin Veno Pro smart lock features, installation, connectivity, security, and troubleshooting. Learn about palm vein recognition, smart home integration, and more.