Opengear User Manual. Page 16. Connect the IM7200 to the network, to the serial ports of the controlled devices, and to power as outlined ...
Opengear User Manual. Page 6. Manual organisa"on. ... Opengear User Manual. Page 8. s can use the Management Console, either locally or from a remote loca!on...
Opengear User Manual. Page 16. Connect the IM7200 to the network, to the serial ports of the controlled devices, and to.
User Manual ACM5000 Remote Site Managers ACM5500 Management Gateways ACM7000 Resilience Gateways IM7200 & IM4200 Infrastructure Managers CM7100 Console Servers Revision 4.3 2016-11-09 User Manual Copyright © Opengear Inc. 2016. All Rights Reserved. Informa!on in this document is subject to change without no!ce and does not represent a commitment on the part of Opengear. Opengear provides this document "as is," without warranty of any kind, expressed or implied, including, but not limited to, the implied warran!es of fitness or merchantability for a par!cular purpose. Opengear may make improvements and/or changes in this manual or in the product(s) and/or the program(s) described in this manual at any !me. This product could include technical inaccuracies or typographical errors. Changes are periodically made to the informa!on herein; these changes may be incorporated in new edi!ons of the publica!on. Safety Follow the safety precau!ons below when installing and opera!ng the console server: · do not remove the metal covers. There are no operator serviceable components inside. Opening or removing the cover may expose you to dangerous voltage which may cause fire or electric shock. Refer all service to Opengear-qualified personnel. · to avoid electric shock the power cord protec!ve grounding conductor must be connected through to ground. · always pull on the plug, not the cable, when disconnec!ng the power cord from the socket. · do not connect or disconnect the console server during an electrical storm. It is recommended you use a surge suppressor or UPS to protect the equipment from transients. Proper back-up systems and necessary safety devices should be u!lized to protect against injury, death or property damage due to system failure. Such protec!on is the responsibility of the user. This console server device is not approved for use as a life-support or medical system. Any changes or modifica!ons made to this console server device without the explicit approval and consent of Opengear will void Opengear of any liability or responsibility of injury or loss caused by any malfunc!on. This equipment is for indoor use only. All the console's communica!on wirings are limited to use inside of a building. FCC warning statement This device complies with Part 15 of the FCC rules. Opera!on of this device is subject to the following condi!ons: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may cause undesired opera!on. Opengear User Manual. Page 4. Publishing history date ed so!ware models features 2010/01 3.8.4 2010/03 3.8.5 2010/06 3.9 3.1 2010/08 3.9.1 3.2 SD4001 ACM5004-G ACM5004-I fixed Failover details & added DDNS. Shadowpassword, °F, SNMP, SMS gateway. OpenVPN, Zenoss, config commit, & Call Home. 2010/12 4.0 3.3 Firewall router, Web Terminal, & SNMP updates. 2011/06 4.1 3.4 GPS, SNMP monitoring & IPv6, 32-port models, & SMS over cellular. 2011/10 4.2 3.5 2011/11 4.3 3.5.2 IM4216-34 2012/02 4.4 3.5.2u3 ACM5500 Auto-Response. PPTP, GRE, Groups, FTPserver, mul!pledialin, & pmshell. Kerberos, CiscoRJinSD4000, &removeKCS. 2012/04 4.5 3.5.2u14 Cellular redial. 2012/07 4.6 3.5.3 2012/12 4.7 3.6 SD4001 rev-01 & SMS ARM, simple key, & Services page. CM4001/4008 EoL. ACM5504-5-G-W-I Authen!cated NTP. & IM4004-5 EoL. 2013/04 4.8 3.7 4G LTE support. 2013/09 4.9 3.8 IM7200 2013/10 4.10 IM7208 & DDC models 2014/01 4.11 3.9 2014/03 4.12 3.10 Dual SIM, SNMP DIO, bulk provisioning, & WEEE. Connec!on Manager network management backend & Auto-Response extensions. 2014/07 4.13 3.11 New SNMP MIB, OpenLDAP, & LDAPS. 2014/09 4.14 3.12 New Manage Devices UI & brute force protec!on. 2014/10 4.15 CM7100 2015/01 4.16 3.15 IP Passthrough 2015/02 4.17 3.15.1 CM4100 EoL. ZTP 2015/06 4.18 3.16 ACM7000 2015/11 4.19 3.16.2 SD4000 EoL. Unauthen!catedSSH & mul!carriercellular. 2016/03 4.20 3.16.4u2 ACM7004-5 2016/04 4.21 Minor document cleanup. 2016/06 4.22 2016/07 4.23 2016/09 4.24 ACM7004-5 RSG Link Layer Discovery Protocol (LLDP). 3.16.5u1 IM7216-2-24U-DAC disabling AAA accoun!ng UI. ZTP (configura!on over DHCP) & USB consoles. 2016/11 4.3 Edits, Copy-edits and re-format throughout. Opengear User Manual. Page 5. This manual The Opengear User Manual describes the features and capabili!es of the following Opengear product lines, and provides instruc!ons to best take advantage of them: Remote Management Gateways ACM5504-5-G/GV-W-I ACM5508-2 ACM5504-5-G/GV-I ACM5508-2-M ACM5504-5-LA/LR/LV-I ACM5008-2-P ACM7005-4 Remote Site Managers ACM5002-F-E ACM5003-M-F-E ACM5004-F-E ACM5004-2-I and -G, -GV, -GS, and -LR models with cellular support. Infrastructure Managers IM7248-2-DAC IM7232-2-DAC IM7216-2-DAC and -LA, -LR, and -LV models with 4G LTE. Infrastructure Managers IM4248-2-DAC IM4248-2-DDC IM4232-2-DAC IM4232-2-DDC IM4216-2-DAC IM4216-2-DDC IM4216-34-DAC IM4216-34-DDC IM4208-2-DAC and -G and -GV models with cellular support. Console Servers CM7116-2-DAC CM7132-2-DAC CM7148-2-DAC Each of these products is referred to generically in this manual as a console server. Where appropriate, product groups may be referred to as console servers, gateways or by specific product line name or product group (for example the IM4200 family or the ACM5500). Who should read this user manual? You should read this manual if you are responsible for evalua!ng, installing, opera!ng, or managing an Opengear appliance. This manual assumes you are familiar with the internal network of your organiza!on, and are familiar with the Internet, IP networks, HTTP, FTP and basic security opera!ons. Opengear User Manual. Page 6. Manual organisa"on The Opengear User Manual is structured as follows: 1. Introductory material An overview of the console server's features and informa!on regarding this manual. 2. Installa!on Physical installa!on of the console server and the interconnec!ng of managed devices. 3. System configura!on Ini!al installa!on and configura!on of the console server and the supported services. 4. Serial port, host, device & user configura!on Configuring serial ports and connected network hosts, and se$ng up users. 5. Firewall, failover, & OOB access Set up the firewall and the high availability access features of the console server. 6. SSH tunnels & SDT connector Secure remote access using SSH and configure for RDP, VNC, HTTP, HTTPS &c access to network- and serially-connected devices. 7. Alerts, auto-response & logging Set up local and remote event and data logs. Configure auto-responses to trigger events. 8. Power, environment, & digital I/O Manage USB, serial and network a%ached power strips and UPS supplies. Also EMD environmental sensor configura!on. 9. Authen!ca!on Access to the console server requires authenitcated usernames and passwords. 10.Nagios integra!on Set Nagios central management. Configure console server as a distributed Nagios server. 11.System management Access to and configura!on of services to be run on the console server. 12.Status reports The dashboard summary and detailed status and logs of serial and network connected devices (ports,hosts,powerand environment). 13.Management Port controls and user-accessible reports. 14.Configura!on from the command line Command line installa!on and configura!on using the config command. 15.Advanced configura!on Advanced command line configura!on ac!vi!es using Linux commands. 16.Appendices Command defini!ons, specifica!ons, cer!fica!ons, terminology defini!ons, licenses, service and warranty details. The most recent version of this manual is always at h%p://opengear.com/support/ documenta!on/. Opengear User Manual. Page 7. Types of users The console server supports two classes of users: 1. First there are administra!ve users, who have unlimited configura!on and management privileges over the console server; and all the connected devices. Administra!ve users are set up as members of the admin user group. Users in this class are referred to in this manual as Administrators. An Administrator can access and control the console server using the config u!lity, the Linux command line or the browser-based Management Console. By default, the Administrator has access to all services and ports to control all the serial connected devices and network connected devices (hosts). 2. The second class of users embraces those who have been set up by an Administrator with specific limits of their access and control authority. These users are set up as members of one of the pre-configured user groups (pptpd, dialin, &p, pmshell or users) or another user groups an Administrator has added. They are only authorized to perform specified controls on specific connected devices and are referred to as Users. These Users (when authorized) can access serial or network connected devices; and control these devices using the specified services (eg Telnet, HHTPS, RDP, IPMI, Serial-over-LAN, Power Control). An authorized User also has a limited view the Management Console and can only access authorized configured devices and review port logs. In this manual, when the term user (lower case) is used, it is referring to both classes of users above. This document also uses the term remote users to describe users who are not on the same LAN segment as the console server. These remote users may be users, who are on the road connec!ng to managed devices over the public Internet. They may be an Administrator in another office connec!ng to the console server itself over the enterprise VPN. Or the remote user may be in the same room or the same office but connected on a separate VLAN to the console server. Management console The features of your console server are configured and monitored using the Opengear Management Console. When you first browse to the Management Console, you can use the menu displayed on the le& side to configure the console server. Once you have completed the ini!al configura!on, you can con!nue to use the Management Console runs in a browser and provides a view of the console server and all the connected devices. Opengear User Manual. Page 8. Administrators can use the Management Console, either locally or from a remote loca!on, to configure and manage the console server, users, ports, hosts, power devices and associated logs and alerts. Users can also use the Management Console, but have limited menu access to control select devices, review their logs and access them using the in-built Web terminal or control power to them. The console server runs an embedded Linux opera!ng system, and experienced Linux and UNIX users may prefer to undertake configura!on at the command line. You can gain command line access by cellular, dial-in, or by directly connec!ng to the console server's serial console port (aka the console server's modem port). The shell can also be accessed by using ssh or Telnet to connect to the console server over a LAN (or by connec!ng with PPTP, IPsec or OpenVPN). Manual conven"ons The Opengear User Manual uses typeface `colour' to dis!nguish between different so&ware elements. · Procedure steps are denoted with bullet-points like this. · Bullet-pointed text is also, on occasion, used to present related items in a list. Bold text in a procedure indicates a user interface element you click on or navigate to. Italic text in a procedure indicates a user interface element that references a variable you can change or set. Italics are also used in the standard typographic fashion to indicate a formal name (the book "tle in the first paragraph of this sec"on, for example). The phrase `console server' -- when referring to any of Opengear's hardware products -- is also italicised throughout. Links, both to external resources and to other places in the manual are set in blue. Mono-spaced type indicates a file-name or shell-based interface element, such as a bash script or application that runs from the bash shell or the Windows command-line. If you might enter the monospaced string at a shell-prompt or in a text-editor, it will be set thus. Note: Not a user-interface element. Indented text set in italics and prefixed with the word `Note:' is text to pay specific a"en#on to. The Opengear User Manual equivalent to the rare but now famous phrase `hic sunt dracones' (here be dragons). Where to find addi"onal informa"on 1. The Quick Start Guide that came with your console server. This provides instruc!ons for the installa!on and configura!on of Opengear hardware. 2. The Opengear Knowledge Base at h%ps://opengear.zendesk.com/. This online resource includes technical how-to ar!cles, !ps, FAQs and important no!fica!ons. Opengear User Manual. Page 9. 1. Installa!on 1.1. Models This chapter describes how to install the console server hardware, and connect it to controlled devices. There are mul!ple families and models, each with a different number of network/serial/USB ports or power supply and wireless configura!ons. Opengear User Manual. Page 10. model serial usb 232 232/422/485 1 2 3 ACM5002-F-E 2 1 ACM5004-F-E 4 1 ACM5003-M-F-E 3 1 ACM5004-G(S/V)-E 41 ACM5004-G(S/V)-I 41 ACM5004-2-I 42 ACM5504-5-G(V)-I 42 ACM5504-5-G-W-I 42 ACM5504-5-Lx-I 42 ACM5508-2 8 2 ACM5508-2-I 82 ACM5508-2-M 8 2 ACM5508-2-L-I 8 2 ACM7004 4 4 ACM7004-5 4 4 ACM7008-2 8 4 IM4248-2-DAC/DC 48 12 IM4232-2-DAC/DC 32 12 IM4216-2-DAC/DC 16 12 IM4208-2-DAC/DC 8 12 IM4216-34-DAC/DC 16 12 IM7208-2-DAC 8 2 IM7216-2-DAC 16 2 IM7232-2-DAC 32 2 IM7248-2-DAC 48 2 network flash console v.92 modem wireless sensors rj pinout* power 100 1000 GB 1 4 n/a n/a n/a temp/probes 02 ext ac/dc 2 4 n/a n/a n/a temp/probes 02 ext ac/dc 1 4 n/a internal n/a temp/probes 02 ext ac/dc 1 0 n/a n/a 3g temp/probes 02 ext ac/dc 1 0 n/a n/a 3g temp & D I/O 02 ext ac/dc 2 0 n/a n/a n/a temp & D I/O 02 ext ac/dc 5 4 n/a n/a 3g temp & D I/O 02 ext ac/dc 5 4 n/a n/a wap, 3g temp & D I/O 02 ext ac/dc 5 4 n/a n/a 4g temp & D I/O 02 ext ac/dc 2 4 n/a n/a n/a temp & D I/O 02 ext ac/dc 2 4 n/a n/a n/a temp & D I/O 02 ext ac/dc 2 4 n/a internal n/a n/a 02 ext ac/dc 2 4 n/a n/a 4g temp & D I/O 02 ext ac/dc 2 4 n/a internal 4g external 02 ext ac/dc 5 4 n/a internal 4g external 02 ext ac/dc 2 4 n/a internal 4g external 02 ext ac/dc 2 16 1 internal 3g opt external 00/01/02 dual ac/dc 2 16 1 internal 3g opt external 00/01/02 dual ac/dc 2 16 1 internal 3g opt external 00/01/02 dual ac/dc 2 16 1 internal 3g opt external 00/01/02 dual ac/dc 34 16 1 internal n/a external 02 dual ac/dc 2 16 1 internal wap, 4g opt external 01/02 dual ac/dc 2 16 1 internal wap, 4g opt external 01/02 dual ac/dc 2 16 1 internal wap, 4g opt external 01/02 dual ac/dc 2 16 1 internal wap, 4g opt external 01/02 dual ac/dc Opengear User Manual. Page 11. model IM7216-2-24U-DAC CM7148-2-SAC CM7116-2-SAC CM7148-2-DAC CM7132-2-DAC CM7116-2-DAC serial usb 232 232/422/485 1 2 3 16 24 2 48 2 16 2 48 2 32 2 16 2 network flash console v.92 modem wireless sensors 100 1000 GB 2 16 1 internal wap, 3g, 4g external 24 1 n/a n/a external 24 1 n/a n/a external 24 1 n/a n/a external 24 1 n/a n/a external 24 1 n/a n/a external IM7200-series models have dual 10/100/1000 LAN ports with two RJ45 ports and two SFP fiber module slots. CM7100-seris modesl have dual 10/100/1000 RJ45 LAN ports. *The RJ pinout values in the model table translate as follows: 00 Opengear Classic. 01 Cisco Rolled. 02 Cisco Straight. rj pinout* power 01/02 02 02 02 02 02 dual ac/dc single ac single ac dual ac dual ac dual ac Opengear User Manual. Page 12. The varuous product families support different so&ware features. model dhcp ddns mgt lan cell or wi-fi oob ACM5000 yes yes yes¹ ACM5500 yes yes yes¹ ACM7000 yes yes yes IM4200 yes yes yes IM7200 yes yes yes CM7100 yes yes yes yes² yes yes² yes yes² yes yes² yes yes² yes no yes autoresponse yes yes yes yes yes yes flash fip ipsec, pptp & (!p & %tp) s openvpn yes³ yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes 1.ACM500x-2, ACM550x-2, ACM5504-5 models only. 2.Selected models have 3G/4G cellular, Wi-Fi Wireless Access Points (WAP) or both. 3.ACM5002-F-E, ACM5003-M-F-E and ACM5004-F-E models only. Note: To avoid physical and electrical hazard please read appendix 3 on Safety The sec!ons below show the components shipped with each of these models. 1.1.1. ACM5000 kit components component part #s ACM5002-F-E, ACM5003-M-F-E, ACM5004-F-E & ACM5004-2-I Remote Site Manager (plus SDC op!ons and -G/GV/GS models with cellular support) 2 x Cable UTP Cat5 blue 440016 Cisco Connector DB9F-RJ45 straight and DB9F-RJ45 cross-over 3190014 3190015 Power Supply 12VDC 1.0A Wall mount 4500XX Quick Start Guide 539000 Unpack the ACM5000 kit and verify you have all the parts shown above, and that they all appear in good working order. The ACM5004-G has an external 3G aerial to be a%ached. Connect the ACM5000 to the network, the serial ports of the controlled servers and AC power as shown below. 1.1.2. ACM5500 kit components component ACM5504-5-G/GV-W-I, ACM5504-5G/GV-I, ACM5504-5-LA/LR/LV-I, ACM5508-2 ACM5508-2-L-I, ACM5508-2-M and ACM5008-2-P Remote Management Gateway 2 x Cable UTP Cat5 blue part #s 440016 Opengear User Manual. Page 13. Cisco Connector DB9F-RJ45 straight and DB9F-RJ45 cross-over 3190014 3190015 Power Supply 12VDC 1.0A Wall mount 4500XX Quick Start Guide 539000 Unpack the ACM5500 kit and verify you have all the parts shown above, and that they all appear in good working order. The ACM5004-5-G(V)-I and ACM5504-5-LA/LR/LV-I models come with an external cellular aerial to be a%ached. The ACM5004-5-G(V)-W-I also has an external 802.11 wireless aerial to be a%ached. Connect the ACM5500 to the network, serial and USB ports of the controlled devices, environmental monitors and AC power as shown below. 1.1.3. ACM7004-2, ACM7004-5, ACM7008-2 kit components component ACM7004-2-LA, ACM7004-2-LR, ACM7004-2-LV, ACM7004-2-LMA, ACM7004-2-LMV, ACM7004-2LMCR, ACM7004-2-LMCT, ACM7008-2-LMA, ACM7008-2-LMV, ACM7008-2-LMR, ACM7008-2LMCR, ACM7008-2-LMCT, ACM7004-5-LMA, ACM7004-5-LMV, ACM7004-5-LMCR, ACM7004-5LMCT 2 x 4G LTE blade antennas DB9F-to-RJ45 crossover serial adapter 12V switching DC power supply Rack kit (1 tab, 1 ear, 2 rack screws, 2 nuts, 4 screws) Quick Start Guide part #s 569028 319015 450031 590003 520085 1.1.4. ACM7005-4 Remote Site Gateway kit components component ACM7004-5 Remote Site Gateway DB9F-to-RJ45 crossover serial adapter 12V switching DC power supply Rack kit (1 tab, 1 ear, 2 rack screws, 2 nuts, 4 screws) Quick Start Guide part #s 319015 450031 590003 520085 Opengear User Manual. Page 14. 1.1.5. IM4208-2, IM4216-2, IM4232-2, IM4248-2, & IM4216-34 kit components component IM4216-2 Infrastructure Manager IM4248-2 Infrastructure Manager IM4208-2 Infrastructure Manager IM4216-34 Management Gateway 2 x Cable UTP Cat5 blue DB9F-RJ45S straight adapter and DB9F-RJ45S cross-over adapter Dual IEC AC power cord (DAC models only) Quick Start Guide part #s 509006 509007 509008 509009 440016 319000 319001 440001 539001 Unpack the IM4200 (IM4208-2, IM4216-2, IM4232-2, IM4248-2 Infrastructure Manager or IM4216-34 Management Gateway) kit and verify you have all the parts shown above, and that they all appear in good working order. If you are installing the IM4200 in a rack you will need to a%ach the rack moun!ng brackets supplied with the unit, and install the unit in the rack. Take care to heed the safety precau!ons listed in appendix 3. Connect the IM4200 to the network, to the serial ports of the controlled devices, and to power as outlined below. 1.1.6. IM7208-2, IM7216-2-24U, IM7232-2, & IM7248-2 kit components component IM7248-2-DAC, IM7232-2-DAC, IM7216-2-24U-DAC, IM7216-2-DAC and IM7208-2-DAC Infrastructure Managers (and -LA/LR/LV models with 4G LTE) 2 x Cable UTP Cat5 blue Cisco Straight and Rolled Connectors DB9M/F -RJ45 Dual IEC AC power cord (DAC models only) Quick Start Guide part #s 440016 319014 319015 319016 319017 319018 319019 440001 539001 Unpack the IM7200 kit and verify you have all the parts shown above, and that they all appear in good working order. If you are installing the IM7200 in a rack you will need to a%ach the rack moun!ng brackets supplied with the unit, and install the unit in the rack. Take care to heed the safety precau!ons listed in appendix 3. Opengear User Manual. Page 15. Connect the IM7200 to the network, to the serial ports of the controlled devices, and to power as outlined below. Note: The IM7208-2-DDC, IM7216-2-DDC, IM7232-2-DDC and IM7248-2-DDC products are DC powered and the kits do not include an IEC AC power cord. 1.1.7. CM7116-2, CM7132-2 and CM7148-2 kit components component CM7116-2 Console Server, CM7132-2 Console Server and CM7148-2 Console Server 2 x Cable UTP Cat5 blue Cisco Connector DB9F-RJ45 straight and DB9F-RJ45 cross-over Dual IEC AC power cord Quick Start Guide part #s 440016 319014 319015 440001 539001 Unpack the CM7116-2 (or CM7132-2/CM7148-2) kit and verify you have all the parts shown above, and that they all appear in good working order. If you are installing the CM7116-2 (or CM7132-2/CM7148-2) in a rack you will need to a%ach the rack moun!ng brackets supplied with the unit, and install the unit in the rack. Take care to heed the safety precau!ons listed in appendix 3. Connect the CM7116-2 (or CM7132-2/CM7148-2) to the network, to the serial ports of the controlled devices, and to power as outlined below. 1.2. Power connec"on 1.2.1. All IM7200, IM4200, & CM7100 DAC models These standard IM7200, IM4200 and CM7100 console servers all have dual universal AC power supplies with auto failover built in. These power supplies each accept AC input voltage between 100 and 240 VAC with a frequency of 50 or 60 Hz and the total power consump!on per console server is less than 30W. Two IEC AC power sockets are located at the rear of the metal case, and these IEC power inlets use conven!onal IEC AC power cords. Power cords for various regions are available, although the North American power cord is provided by default. There is a warning no!ce printed on the back of each unit. Note: To avoid electrical shock the power cord grounding conductor must be connected to ground. 1.2.2. All ACM5000 & ACM7000 models All ACM5000 models are supplied with an external AC-12V DC wall-mount power supply. This comes with a selec!on of wall socket adapters for each geographic region (North Opengear User Manual. Page 16. American, Europe, UK, Japan or Australia). The 12V DC connector from the power supply unit plugs into the 12V DC (PWR) power jack on the side of the console server casing. · Plug in the power supply AC power cable and the DC power cable. · Turn on the AC power and confirm the console server Power LED (PWR) is lit. The ACM5000 models can also be powered from an external +9V DC to +30V DC power source by connec!ng the DC power lines to a power plug that plugs into the 12VDC (PWR) jack. The industrial ACM5004-2-I model can also be powered externally by connec!ng a +9 to +30V DC power source to the DC PWR and GND connectors on the green screw terminal block on the side of the unit. Note: All ACM5000 models can also be ordered with the -SDC op#on. These units are supplied with an external DC-DC power converter. This converter has an integrated power cable/connector that plugs into the 12VDC (PWR) connector on the ACM5000. The input voltage for the DC-DC converter is plus or minus 36V DC to 72V DC 1.2.3. All ACM5500 models All the ACM5500 models are supplied with an external AC-12VDC wall mount power supply. This comes with a selec!on of wall socket adapters for each geographic region (North American, Europe, UK, Japan or Australia). The 12V DC connector from the power supply unit plugs into the 12VDC (PWR) power jack on the side of the console server casing. · Plug in the power supply AC power cable and the DC power cable. · Turn on the AC power and confirm the console server Power LED (PWR) is lit. The ACM5500 models can also be powered via an external +9V DC to +30V DC power source. Connect the DC power lines to a power plug that plugs into the 12VDC (PWR) jack. The ACM5500 can also be powered via an external 9V AC to 24V AC power source to this jack. The industrial ACM5508-2-I and ACM5504-5-GI models also can be powered externally by connec!ng a +9 to +30V DC power source to the EXT 9-30V DC and GND connectors on the green screw terminal block on the side of the unit. Note: An external DC-DC power converter can be ordered as an accessory with any ACM5500 remote management gateway. This converter has an integrated power cable/connector that plugs into the 12VDC (PWR) connector on the ACM5500. The input voltage for the DC-DC converter is plus or minus 36V DC to 72V DC. 1.2.4. IM7200-DDC & IM4200-DDC The -DDC model console servers all have dual DC power supplies with auto failover built in. To Opengear User Manual. Page 17. connect to the DC input supply: · Strip the DC wire insula!on to expose approximately 10 mm (0.4) of conductor. · Connect the safety ground wire to the `E' safety ground terminal on the terminal block first. The DDC is floa!ng (with regards to Earth), however the safety terminal on the three way screw terminal block connects to Earth or Chassis Ground. · Connect the power wires to the appropriate terminals of the terminal block. The + terminal on the four way screw terminal block should always be connect to the more posi!ve voltage (from 0V to +48 V). The - terminal on the four way screw terminal block should connect to the more nega!ve voltage (from -48V to 0V). So the connec!ons for -48 Volt DC input power are: The connec!ons for +48 Volt DC input power are: · Tighten the terminal screw to a torque of 0.93 ± 0.05 Nm (8.0 ± 0.5 inlbf). · Repeat the connec!on steps above for the second power supply. · Turn on the DC power. Note: The safety covers are an integral part of the DDC product. Do not operate the unit without the safety cover installed. Note: Any exposed wire lead from a DC-input power source can conduct harmful levels of electricity. So ensure that no exposed por#on of the DC-input power source wire extends from the terminal block plug and safety cover. 1.3. Network connec"on All Opengear console servers all ship with Ethernet ports. These ports are located on the front panel of the rack-mount IM4200 units; the rear panel of the rack-mount CM7100 units; and on the side of the smaller ACM7000, ACM5500 and ACM5000 units. All physical connec!ons are made using industry standard Cat5 cabling and connectors. Ensure you only connect the LAN port to an Ethernet network that supports 10/100, or 10/100/1000 (IM7200, CM7100, ACM7000 only). Opengear User Manual. Page 18. The IM7200 has four physical input ports which are logically presented as two ports (NET1 & NET2). Each logical port consists of a copper 10/100/1000 port and a fiber-op!c small formfactor pluggable (SFP) module slot. The ACM7004-5 has six physical input ports: an SFP port and an RJ45 port on the front of the device which are logically paired and marked as NET1; and four RJ45 ports on the back of the device which cons!tute an independent Ethernet switch and which are marked as NET2. On all devices with logically-paired SFP and RJ45 ports, you can use only one of the two physical ports at a !me: either the SFP module port or the 10/100/1000 port. As well, and again on all console servers with logically-paired SFP and RJ45 ports, the fiberop!c medium (ie, the SFP module) has priority over the copper medium (ie the RJ45 port). Only if the SFP module is not plugged in, does the RJ45 copper link becomes ac!ve. This applies regardless of the connec!on order. If the SFP module is plugged in a&er the copper medium has established a link, the copper link is disconnected and the fiber-op!c medium becomes ac!ve. For the ini!al configura!on of the console server you must connect a computer to the console server's principal network port. This port is labeled NET1 (on IM7200 and CM7100), NETWORK1 (on IM4200), LAN1 (on ACM7000 and ACM5500) and LAN USB1 (on ACM5000). 1.4. Serial port connec"on Console servers all come with one to forty eight serial ports, marked SERIAL or SERIAL PORTS. These ports connect to serially Managed Devices. Each console server also has either a dedicated Local Console (or modem) port marked LOCAL or CONSOLE, or one or its SERIAL ports can be so&ware configured in Local Console mode. This Local Console port can be used for local command line access (or external serial modem out of band connec!on). All console server models except the ACM5000, ACM5500 and ACM7000 have a dedicated local RS232 Console port. This is a DB9 connector located on the front of the IM4200 models, and a RJ45 connector (Cisco Straight) located on the front of the IM7200 and CM7100 models. ACM5000, ACM5500 and ACM7000 models have two, three, four, or eight serial ports presented as RJ45 ports 1x. By default, port 1 on all these models is configured in Local Console mode. Conven!onal Cat5 cabling with RJ45 jacks is generally used for serial connec!ons. Opengear supplies a range of cables and adapters that may be required to connect to the more popular servers and network appliances. These are also overviewed in appendix 4. More detailed informa!on is available online at h%ps://opengear.zendesk.com/forums/21087337-cabling. Before connec!ng the console port of an external device to the console server serial port, confirm that the device does support the standard RS-232C (EIA-232). The console servers come with one to forty eight serial connectors for the RS232 serial ports: The RJ45 serial ports are located on the front face of the ACM5000 and ACM5500; on the rear of the ACM7000; on the front panel of the rack mount IM4200; and on the rear panel of the rack mount IM7200. Opengear User Manual. Page 19. The ACM5000, ACM5500, ACM7000, CM7100 and IM4216-34 models have Cisco Straight serial pinouts on the RJ45 connectors (see chapter 1.4.3 below). All serial ports on the IM7200 are RJ45 and are so&ware selectable for Cisco Straight or Cisco Rolled pinout. The IM4200 family is available with a selec!on of alternate RJ45 pinouts e.g. the IM4208-2, IM4216-2 and IM4248-2 console servers have three RJ45 pinout configura!ons available: Opengear Classic, Cisco Straight or Cyclades/Cisco Rolled (see chapter 1.4.1). These alternate pinouts need to be specified in the part number at the !me of order e.g. to order an IM4248-2 dual power supply AC USA model, specify: IM4248-2-DAC-X2-US for a unit equipped with Cisco Straight RJ pinouts (straight through cable). IM4248-2-DAC-X1-US for a unit equipped with Cyclades/Cisco Rolled RJ pinouts (rolled cable connec!on). IM4248-2-DAC-X0-US for a unit equipped with Opengear Classic RJ pinouts. Some console server models support RS-422 and RS-485 as well as RS-232. The four RJ45 serial ports on the ACM5004-2-I and ACM5504-5-G-I are each RS-232/422/485 so&ware selectable as are the eight RJ45 serial ports on the ACM5508-2-I. See appendix 4 for RS422/485 pinout and connec!on details. In summary: model ACM500x ACM5004-I ACM550x # 2,3,4 4 4,8 connector RJ RJ RJ serial ports pinout X2 Cisco X2 Cisco X2 Cisco rs232 rs422/485 yes no yes yes yes no console port no¹ no¹ no¹ 1.The first serial port can be reassigned to be a console port. 1.4.1. Opengear Classic RJ45 The IM4200 console servers are also available with this RJ45 pinout as an op!on: pin signal defini"on 1 RTS request to send 2 DSR data set ready direc"on output input Opengear User Manual. Page 20. 3 DCD data carrier detect input 4 RXD receive data input 5 TXD transmit data output 6 GND signal ground n/a 7 DTR data terminal ready output 8 CTS clear to send input 1.4.2. Cisco Rolled (Cyclades) RJ45 pinout (op"on -X1) The IM4200 console servers are available with this RJ45 pinout op!on. The IM7200 console servers can select this pinout. This makes it easy to replace Avocent Cyclades products, and is convenient for use with rolled RJ45 cable: pin signal defini"on direc"on 1 RTS request to send output 2 DTR data terminal ready output 3 TXD transmit data output 4 GND signal ground n/a 5 CTS clear to send input 6 RXD receive data input 7 DCD data carrier detect input 8 DSR data set ready input 1.4.3. Cisco RJ45 pinout The ACM5000, ACM5500, ACM7000, CM7100 and IM4216-34 models have Cisco serial pinouts on its RJ45 connectors. The IM4200 console servers are also available with this RJ45 pinout. The IM7200 console servers can select this pinout (it is the default). This provides straight through RJ45 cable to equipment such as Cisco, Juniper, Sun, and many more: pin signal defini"on direc"on 1 CTS clear to send input 2 DSR data set ready input 3 RXD receive data input 4 GND signal ground n/a 5 GND signal ground n/a 6 TXD transmit data output 7 DTR data terminal ready output 8 RTS request to send output 1.5. USB port connec"on Most console servers have external USB ports. IM7200s have USB 3.0 ports. On other models these ports are mostly USB 2.0. They can be used for: connec!ng to UPS or PDU managed devices (for managing UPS supplies, for example). connec!ng an external USB memory s!ck Opengear User Manual. Page 21. connec!ng to USB Consoles. NB: IM4200/ACM5xx/550x support 2 Cisco Consoles only. Some console server models also have a USB1.1 port and this is best reserved for use with an external USB memory s!ck dedicated to recovery firmware boot images, extended log file storage or both. All the IM4200-X models with internal cellular have one USB1.1 port on the front face and one USB 2.0 port at the rear face. This USB2.0 port uses a micro-AB USB connector so an adapter cable is also included. These models also have 16GB flash installed internally via a USB 2.0 flash drive for improved logging All the other models in the IM4200-X family (IM42xx-2-DxC-Xx models such as IM4208-2DAC-X0, IM4248-2-DDC-X2 and IM4216-34-DAC-X2) have one USB1.1 port on the front face and two addi!onal USB 2.0 ports at the rear face (adjacent to modem jack). These IM4200-X models also have an internal 16GB flash drive The IM7216-2-24U, like all other IM7200-series models, has two front-facing USB 3.0 ports. The IM7216-2-24U also has 24 rear-facing USB 2.0 ports. These rear-facing USB ports are presented as serial ports 1740 and support USB console connec!ons to devices from a wide range of vendors, including Cisco, HP, Dell and Brocade. Moreover, and aside from their u!lity as USB connec!ons, all IM7216-2-24U USB ports can func!on as plain RS-232 serial ports when a USB-to-serial adapter is connected. The IM7216-2-24U's two front-facing USB ports are presented as Front, Upper USB and Front, Lower USB respec!vely. And, although these two ports can also be used as serial ports with a USB-to-serial adapter, in most instances it is expected the front-facing ports will be used on the IM7216-2-24U as they are used on other IM7200-series models: to connect to USB consoles on UPS supplies or Cisco devices; and for in-situ flash drive a%achment to load updated firmware or saved configura!on files. Some console server models also come with internal USB connec!ons to cellular modem and/ or flash memory. The ACM5500 models all have an internal 4GB USB flash drive as well as two unallocated external USB2.0 ports. The ACM7000 models all have an internal 4GB USB flash drive as well as four unallocated external USB2.0 ports. These four unallocated USB ports are labelled 1 4 on the device itself and in the Web interface. Note: a handful of ACM-7004-5s were manufactured with physical labels A D on the four USB ports. If you have such an ACM-7004-5, be aware the Web interface s!ll denotes them as USB ports 1 4, as it does with other 7000-series devices. The ACM5000 models have two USB2.0 ports. However one or both of these may be preallocated internally. For example the ACM5004-G has one internal USB commi%ed for the cellular modem adapter, so there is only one external USB port free. Similarly with ACM5004F-E model an internal USB flash is fi%ed, using up one of the two USB2.0 ports. 1.6. Fi&ng Cellular SIM and Antennas The ACM5504-5-G-W-I, ACM5504-5-G-I, ACM5004-G-E and ACM5004-G-I models each have an internal 3G cellular modem that requires at least one (or more) SIM cards to be installed and at least one external cellular antenna to be a%ached. The ACM5000-GV/GS and ACM5500-GV/GS models also have an internal cellular modem requiring external antenna Opengear User Manual. Page 22. connec!on. However the Verizon and Sprint 3G networks do not require a SIM card. Similarly the IM4200-2-DAC-X2-G and IM4216-34-DAC-X2-G models have an internal 3G cellular modem that requires a SIM card and external antenna. The IM4200-2-DAC-X2-GV/ GS and IM4216-34-DAC-X2-GV/GS models also have an internal cellular modem requiring external antenna connec!on however they do not require a SIM card. The ACM5504-5-LA/LR/LV-I, ACM7004-2-LA/LR/LV, ACM5004-LR, ACM5004-LR-I and IM7200-LA/LR/LV/LM-I models all have an internal 4G LTE cellular modem that requires at least one SIM card to be installed and two external cellular antennas to be a%ached. The ACM5504-5-G-W-I and all IM7200 models also have an internal 802.11 wireless modem that requires at least one external WiFi antenna to be a%ached. 1.6.1. ACM5004 -G & -L models The ACM5000 -GV/-GS/-G work with Verizon USA, Sprint USA and global GSM carriers including AT&T USA, respec!vely. The ACM5000 -LR models work with global GSM carriers (outside the USA). Your carrier will provide you with a SIM card for ac!va!ng you data plan (-G models only). Note: you must install the SIM card before powering on the device. Unscrew the cover plate on the side of the insert the SIM into the SIM garage then screw the cover plate back on. Note: take care to inset with contacts facing upwards as shown. Screw the provided antenna on to the MAIN SMA antenna connector on the rear of the unit. Then place the unit and/or aerial in a loca!on that will ensure the best signal. These models come with dual SMA antenna connectors. The AUX connector can be used for receive diversity. This requires an external antenna (accessory Part# 569006) and cable (Part# 449041). With -I models, the AUX connector can also be used for GPS. An external GPS passive antenna with magne!c base, SMA connector and 2 meter cable is available (Part # 569008). These models have two cellular status LEDs. The SIM LED on top of unit should go on solid when powered and a SIM card has been inserted and detected. The WWAN LED on top of the unit should go on at a fast blink once a radio connec!on has been established with your cellular carrier (that is, a&er an APN has been properly configured). WWAN LED Status: Off: Slow blink: Solid Green: Fast Blink: in reset mode or not powered. searching for service. ac!ve service; no traffic detected. ac!ve service; traffic (blink propor!onal to traffic detected). Opengear User Manual. Page 23. 1.6.2. ACM5500 -G models The ACM5500 -GV/-GS/-G work with Verizon USA, Sprint USA and global GSM carriers including AT&T USA, respec!vely. Your carrier will provide you with a SIM card for ac!va!ng you data plan (-G models only). Note: you must install the SIM card before powering on the device. -G-I models can hold two SIM cards from alternate carriers, however only requires one SIM to operate. Unscrew the SIM card access panel and insert the first carrier SIM card in the bo%om SIM slot. A second carrier SIM can also be installed in the slot above the first. Screw the cover plate back on. Note: Take care to insert the SIM cards with contacts facing downward and the notch to the right-hand side. Screw the provided cellular antenna on to the main Cell (M) connector on the rear of the ACM5504-G-I. Then place the unit and/or aerial in a loca!on that will ensure the best signal. The ACM5504-5-G-I has a second SMA antenna connector. This Cell (A) connector can be used for receive diversity. This requires an external antenna (accessory Part# 569006) and cable (Part# 449041). The ACM5504-5-G-I has a second SMA antenna connector. This Cell (A) connector can be used for receive diversity. This requires an external antenna (accessory Part# 569006) and cable (Part# 449041). Alternately, the Cell (A) connector can be used for GPS. An external GPS passive antenna with magne!c base, SMA connector and 2 meter cable is available (Part # 569008). The ACM5504-5-G(V)-W-I models have an internal 802.11 WiFi adapter and come with an external WiFi antenna. Screw wireless antenna on to the main WIFI (M) connector. The ACM5504-5-G(V)-W-I has a second WiFi antenna connector. This WIFI (A) connector can be used for diversity and requires an external antenna (part # 569011). 1.6.3. ACM5500 -L models The ACM5500 -LA/-LV/-LR models work with AT&T USA, Verizon USA, or global 4G LTE carriers respec!vely. Your carrier will provide you with a SIM card for ac!va!ng you data plan. -LR models can hold two SIM cards from alternate carriers, however only one SIM is required. Note: you must install the SIM card before powering on the device. Unscrew the SIM card access panel and insert the first carrier SIM card in the bo%om SIM slot. A second carrier SIM can also be Opengear User Manual. Page 24. installed in the slot above the first. Note: double check you inserted the SIM card in the bo"om SIM slot with contacts facing downward and the notch to the right-hand side. Then replace the SIM card access panel. ACM5500-L models are supplied with two external 7-band cellular antennas. Screw the provided antennas on to the main Cell (M) and diversity Cell (A) SMA connectors on the rear panel. An external GPS passive antenna with magne!c base, SMA connector and 2 meter cable is available (Part #569008). It is screwed on to the GPS SMA connector on the rear panel. 1.6.4. ACM7000 -L models `-L' model ACM7000s come with internal 4G LTE modems and either single (ACM7004-2-LA and ACM7004-2-LR) or dual (all other `-L' ACM7000-series models) mini-SIM card slots. The -LA and -LMA models work with AT&T USA. The -LV and -LMV models work with Verizon USA. And the -LR and -LMR models work with global 4G LTE carriers. NB: -LM models are also mul!-carrier. The ACM7004-5-LMA, for example, works with AT&T USA by default but can be re-set to work with Verizon USA. Likewise with a model like the ACM7008-2-LMV: it works with Verizon USA by default but can be re-set to work with AT&T USA. Whichever carrier you choose, their SIM card ac!vates the data plan and must be installed before powering on the device. On single-SIM models, simply slide the carrier's SIM card into the slot on the front of the device, making sure the contacts are facing upwards and the notch is poin!ng outwards as the card slides into place. Dual-SIM models use a SIM cradle. The cradle holds the SIM card or cards and slides into the dual-SIM-card slot on the front of the device. The bo%om slot is the default slot. If you have a dual-SIM ACM7000 and only one SIM card, insert the card into the bo%om slot of the SIM cradle. No ma%er the specific configura!on, SIM cards go into the cradle with the contacts upwards and the notch inward and adjacent to the longer cradle arm. ACM7000 -L models also come with two external 7-band celluar antennas. Screw the provided antennas on to the main Cell (M) and diversity Cell (A) SMA connectors on the rear panel. An external GPS passive antenna with magne!c base, SMA connector and 2 meter cable is available (Part #569008). It is screwed on to the GPS SMA connector on the rear panel. 1.6.5. IM4200 -G models The IM4200-2-DAC-X2/X0-G and IM4216-34-DAC-X2-G models have an internal 3G-GSM HSUPA/UMTS cellular modem (and an internal 16GB flash memory and an addi!onal USB port at the rear). They are also supplied with an external antenna with extension cable, and a USB adapter cable. They work with global GSM carriers. Before powering on the console server: · Your carrier will provide you with a SIM card. Insert the SIM card (1). It will lock into place. Opengear User Manual. Page 25. Note: Take care to insert SIM with contacts facing downward. · Screw the external antenna coax cable onto the MAIN screw mount SMA connector on the rear of the console server (2). · The AUX connector can be used either for receive diversity (requires external antenna Part# 569006 and cable Part# 449041) or for GPS (requires external GPS passive antenna with cable Part# 569008). The IM4200-2-DAC-X2/X0-GV/GS and IM4216-34-DAC-X2-GV/GS models also have an internal cellular modem (and an internal 16GB flash memory and an addi!onal USB port at the rear). They do not require a SIM card, but the supplied external antenna is installed as above. These models work with Verizon USA and Sprint USA respec!vely. 1.6.6. All IM7200 models All the IM7200 models have an internal 802.11 WiFi adapter and come with an external WiFi antenna. Before powering on the IM7200: · Screw wireless antenna on to the WIFI (MAIN) SMA connector. The IM7200 has a second WiFi antenna connector. This WIFI (AUX) connector can be used for diversity and requires an external antenna (part #569022). 1.6.7. IM7200 -L models The IM7200- LA, LV, LR, LMA, and LMV models have a SIM card slot and three SMA cellular antenna connectors (for cellular with receive diversity and GPS). LA models work with AT&T USA. LV models work with Verizon USA. LR models work with global 4G LTE carriers. LMA models default to AT&T but are mul!carrier in the United States and also work with Verizon. LMV models default to Verizon but are mul!carrier in the United States and also work with AT&T. Included in the kit are two cellular antennas (with one 10 foot coaxial cable and magne!c antenna screw mount base for moun!ng outside the rack). If cellular signal strength is an issue, higher gain and direc!onal antennas can be sourced. Before powering on the IM7200 -LA/-LV/-LR: · Screw one antenna (or antenna cable) onto the CELL (MAIN) screw mount (1) and the diversity antenna, onto the CELL (AUX) connector. Note: if you have purchased a GPS antenna, screw it on to GPS. · Your carrier will provide you with a SIM card. Insert the card into the SIM CARD slot and it Opengear User Manual. Page 26. will lock into place (2). Note: Take care to insert SIM card with contacts facing downwards. 1.7. Digital I/O & environmental sensors ACM5000 or ACM5500 models with an -I in the model number or ACM5000 models with the -E op!on ship with an external green connector block for a%aching environmental sensors and digital I/O devices. Plug in this block and screw in any external devices. On the ACM5508-2-I, ACM5504-5-G-I, ACM5504-5-LA/LR/LV-I, ACM5004-2-I, ACM5004G/LR-I models this block can also be used for connec!ng the external DC power source. ACM7000 models ship with an in-built, black, spring cage I/O connector block for a%aching environmental sensors and digital I/O devices. It cannot be used for connec!ng an external DC power source. See chapter 7 for further details. Opengear User Manual. Page 27. 2.System configura!on This chapter provides step-by-step instruc!ons for the ini!al configura!on of your console server, and connec!ng it to the Management or Opera!onal LAN. This involves the Administrator: · ac!va!ng the Management Console. · changing the Administrator password. · se$ng the IP address console server's principal LAN port. · selec!ng the services to be enabled and access privileges. This chapter also discusses the communica!ons so&ware tools that the Administrator may use in accessing the console server, and the configura!on of the addi!onal LAN ports. Note: for guidance on configuring large numbers of Opengear appliances and/or automa#ng provisioning, please consult the sec#ons en#tled `Bulk Provisioning and Zero Touch Provisioning'. 2.1. Management console connec"on Your console server comes configured with the following default IP address and subnet mask: · IP address: 192.168.0.1. · Subnet mask: 255.255.255.0. For ini!al configura!on it is recommended the console server be connected directly to a single Opengear User Manual. Page 28. computer. If you choose to connect the console server and computer to a LAN before comple!ng the ini!al setup steps the following condi!ons must be met: · there must be no other devices on the LAN at IP address 192.168.0.1. · the console server and the computer must be on the same LAN segment, with no interposed router appliances. 2.1.1. Connected computer setup To configure the console server with a browser, the connected PC/worksta!on should have an IP address in the same range as the console server (for example, 192.168.0.100): To configure the IP address of a computer running Linux, macOS, or Unix: · run ifconfig. To configure the IP address of a computer running Windows: · Click Start -> (Se!ngs ->) Control Panel and double click Network Connec"ons (for Windows 95/98/Me, double-click Network). · Right-click on Local Area Connec"on and select Proper"es. · Select Internet Protocol (TCP/IP) and click Proper"es. · Select Use the following IP address and enter the following details: IP address: Subnet mask: 192.168.0.100 255.255.255.0 · If you want to retain your exis!ng IP se$ngs for this network connec!on, click Advanced and add the above details as a secondary IP connec!on. If it is not convenient to change your computer's network address, you can use the ARPPing command to reset the console server's IP address. To do this from a computer running Windows: · Click Start -> Run (or select All Programs > Accessories > Run). · Type cmd and click OK to bring up the cmd.exe shell prompt . · Type arp d to flush the ARP cache. · Type arp a to view the current ARP cache (this should be empty). Opengear User Manual. Page 29. Now add a sta!c entry to the ARP table and ping the console server to assign the IP address to the console server. In the example below, a console server has the MAC Address 00:13:C6:00:02:0F (designated on the label on the bo%om of the unit) and its IP address is set to 192.168.100.23. Note: the computer issuing the arp command must be on the same network segment as the console server (that is, have an IP address of 192.168.100.xxx). · On Windows: type arp -s 192.168.100.23 00-13-C6-00-02-0F · On Linux, macOS or Unix: type arp -s 192.168.100.23 00:13:C6:00:02:0F · Type ping -t 192.18.100.23 to start a con!nuous ping to the new IP Address. · Turn on the console server and wait for it to configure itself with the new IP address. It will start replying to the ping at this point. · Type arp d to flush the ARP cache again. 2.1.2. Browser connec"on Launch or switch to your preferred browser on the connected computer and enter https:// 192.168.0.1. Note: Console servers ship with a self-signed SSL cer#ficate and are factory configured with HTTPS access enabled and HTTP access disabled. The Management Console supports all current versions of the popular browsers: Internet Explorer, Firefox, Chrome, Safari and more. You will be prompted to log in. · Enter the default administra!on username and administra!on password: Opengear User Manual. Page 30. Username: Password: root default A Welcome page, which lists ini!al configura!on steps, will display. These steps are: · Change default administra!on password (Users page. See chapter 2.2.) · Configure the local network se$ngs (System/IP page. See chapter 2.3.) · Configure serial ports se$ngs (Serial & Network/Serial Port page. See chapter 3.) · Configure user port access (Serial & Network/Users page. See chapter 3.) If your system has a cellular modem steps to configure the cellular router features will also present: · Configure the cellular modem connec!on (System/Dial page. See chapter 4.) · Allow forwarding to the cellular des!na!on network (System/Firewall page. See chapter 4.) · Enable IP masquerading for cellular connec!on (System/Firewall page. See chapter 4.) A&er comple!ng each of the above steps, return to the configura!on list by clicking the Opengear logo in the top le& corner of the page. Note: if you are not able to connect to the Management Console at 192.168.0.1 or if the default Username and Password were not accepted then reset your console server (See chapter 10). 2.2. Administrator set-up 2.2.1. Change default root system password For security reasons, only the administra!ve user named root can ini!ally log into a console server. So only those people who know the root password can access and reconfigure the console server itself. The corollary is that anyone who correctly guesses the root password can gain access and control of a console server. And the ini!al root password is default. It is essen!al, therefore to Opengear User Manual. Page 31. enter and confirm a new password before giving the console server any access to, or control of, other computers and network appliances. · Select Change default administra"on password from the Welcome page. · The Serial & Network > Users & Groups page loads. From here a new, confirmed password for the root user can be set. Note: There are no character restric#ons in a console server user's password. And passwords can be up to 254 characters long. Only the first eight characters are used to make the password hash, however. · If the console server has flash memory (such as the IM7200) you will be given the op!on to Save Password across firmware erases. Checking this will save the password hash in the non-vola!le configura!on par!!on, which does not get erased on firmware reset. Take care as if this password is lost, however. In such an event, the affected console server will need to be firmware recovered. · Click Apply. Since the root password has changed a new log-in prompt will present. This !me use the new password. 2.2.2. Setup a new administrator A new Administrator user should be setup and this new user should be used for ongoing console server administra!on, rather than relying on the root user. This new user can be configured in the admin group with full access privileges by selec!ng Serial & Network > Users & Groups >Add a New User (see chapter 2.2 for details). Opengear User Manual. Page 32. 2.2.3. Name the system · Select System > Administra"on. · Enter a System Name and System Descrip"on for the console server to give it a unique ID and make it simple to iden!fy. Note: The System Name can contain from 1 to 64 alphanumeric characters as well as the following special characters . - _. There are no restric#ons on the characters that can be used in the System Descrip#on, which can contain up to 254 characters. · Op!onal: text entered in the MOTD Banner field is displayed to users when the log-in to the console server. · Click Apply. Note: If you are not confident your console server has been supplied with the current release of firmware, you can upgrade it. (See chapter 10 for details.) 2.3. Network configura"on The next step is to enter an IP address for the principal Ethernet (LAN/Network/Network1) port on the console server; or enable its DHCP client so that it automa!cally obtains an IP address from a DHCP server on the network it is to be connected to. · On the System > IP menu select the Network Interface page then check DHCP or Sta"c for the Configura"on Method. · If you selected Sta"c you must manually enter the new IP Address, Subnet Mask, Gateway and DNS server details. This selec!on automa!cally disables the DHCP client. · By default the console server LAN port auto detects the Ethernet connec!on speed. To lock the Ethernet port to 10 Mb/s or 100Mb/s and to Full Duplex (FD) or Half Duplex (HD) select a speed and duplex se$ng from the Media pop-up menu. If you encounter packet loss or poor network performance with the default autonego!a!on se$ng, try manually se$ng the Media se$ngs on both the console server and Opengear User Manual. Page 33. the device it is connected to. In most cases, select 100baseTx-FD (100 megabits, full duplex). Make sure both sides are set iden!cally. · If you selected DHCP the console server will look for configura!on details from a DHCP server. This selec!on automa!cally disables any sta!c address. The console server's MAC address can be found on a label on the base plate. In its factory default state (with no Configura"on Method selected) the console server has its DHCP client enabled, so it automa!cally accepts any network IP address assigned by a DHCP server on your network. In this ini!al state, the console server will then respond to both its Sta!c address (192.168.0.1) and its newly assigned DHCP address. You may also enter a secondary address or comma-separated list of addresses in CIDR nota!on as an IP Alias. For example: 192.168.1.1/24. Note: If you changed the console server's IP address, you may need to reconfigure your computer so it has an IP address that is in the same network range as this new address (as detailed earlier in this chapter). · Click Apply. · Reconnect the browser on the computer that is connected to the console server by entering https://new-ip-address-here/. 2.3.1. IPv6 configura"on By default, the console server Ethernet interfaces support IPv4. They can also be configured for IPv6 opera!on, however. · Select System > IP. · Click the General Se#ngs tab. · Check the Enable IPv6 check box. · Click the Network Interface to access the IPv6 se#ngs sec!on. Opengear User Manual. Page 34. · Configure the IPv6 se#ngs. 2.3.2. Dynamic DNS (DDNS) configura"on With Dynamic DNS (DDNS) a console server which IP address is dynamically assigned (and that may change from !me to !me) can be located using a fixed host or domain name. · The first step in enabling DDNS is to create an account with the supported DDNS service provider of your choice. Supported DDNS providers include: provider url DyNS h%p://dyns.cx/ Dyn h%ps://dyn.com/ GNUDip h%p://freecode.com/projects/ gnudip Pubyun h%p://pubyun.com/ notes formerly DynDNS. An open-source DDNS tool for use by ISPs. Check if your ISP supports GNUDip. Chinese DDNS provider. Formerly operated as 3322.org. Note: Two previously supported DDNS providers are ODS, which is no longer opera#ng, and TZO, which was bought by Dyn and is no longer opera#ng independently. Upon registering with the DDNS service provider, select a username and password, as well as a hostname that you will use as the DNS name (to allow external access to your machine using a URL). Dynamic DNS service providers allow the user to choose a hostname URL and set an ini!al IP address to correspond to that hostname URL. Many Dynamic DNS providers offer a selec!on of URL hostnames available for free use with their service. However, with a paid plan, any URL hostname (including your own registered domain name) can be used. You can now enable and configure DDNS on any of the Ethernet or cellular network connec!ons on the console server (by default DDNS is disabled on all ports): · Select the DDNS service provider from the drop down Dynamic DNS list on the System > IP or System > Dial menu. · In DDNS Hostname enter the fully qualified DNS hostname for your console server (for example, your-hostname.dyndns.org. Opengear User Manual. Page 35. · Enter the DDNS Username and DDNS Password for the DDNS service provider account. · Specify the Maximum interval between updates in days. A DDNS update will be sent even if the address has not changed. · Specify the Minimum interval between checks for changed addresses in seconds. Updates will s!ll only be sent if the address has changed. · Specify the Maximum a$empts per update (that is, the number of !mes to a%empt an update before giving up). By default this is set to 3. 2.4. Services and service access The Administrator can access the console server, connected serial ports, and managed devices using a range of access protocols and services. For each such access: · the par!cular service must first be configured and enabled to run on the console server. · then access through the firewall must be enabled for each network connec!on. To enable and configure a service: · Navigate to System > Services. · Select the Service Se!ngs tab. Opengear User Manual. Page 36. Note: With firmware releases prior to version 3.5.3, services are enabled and configured using the Service Access tab on the System > Firewall page. · Enable and configure basic services. · HTTP By default the HTTP service is running and it cannot be fully disabled. However by default HTTP access is disabled on all interfaces and it is recommended this access remains disabled, if the console server is to be remotely accessed over the Internet. Alternate HTTP also enables you to configure an alternate HTTP port to listen on. However the HTTP service will con!nue internally listening on TCP port 80 (for CMS and sdt-connector communica!ons) but will be inaccessible through the firewall. · HTTPS By default the HTTPS service is running and this service is enabled on all network interfaces. It is recommended that only HTTPS access be used if the console server is to be managed over any public network (e.g. the Internet). This ensures the Administrator has secure browser access to all the menus on the console server. It also allows appropriately configured Users secure browser access to selected Manage menus. For informa!on on cer!ficate and user client so&ware configura!on see chapter 8, Authen!ca!on. The HTTPS service can be completely disabled (or re-enabled) by checking HTTPS Web Management and an alternate port specified (default port is 443). · Telnet By default the Telnet service is running. However by default the service is disabled on all network interfaces. Telnet can be used to give the Administrator access to the system command line shell. While this may be suitable for a local direct connec!on over a management LAN, it is recommended this service be disabled if the console server is to be remotely administered. This service may also be useful for local Administrator and the User access to selected serial consoles. The Enable telnet command shell checkbox will completely enable or disable the telnet service. An alternate telnet port to listen on can be specified in Alternate Telnet Port (default port is 23). · SSH This service provides secure SSH access to the console server and a%ached devices and by default the SSH service is running and enabled on all interfaces. It is recommended you choose SSH as the protocol where the Administrator connects to the console server over the Internet or any other public network. This will provide authen!cated communica!ons between the SSH client program on the remote computer and the SSH sever in the console server. For more informa!on on SSH configura!on see chapter 8, Authen!ca!on. The Enable SSH command shell checkbox will completely enable or disable this service. An alternate SSH port to listen on can be specified in SSH command shell port (default port is 22). · Enable and configure other services. Opengear User Manual. Page 37. · TFTP/FTP If a USB flash card or internal flash is detected on a console server (for example, an ACM5000, ACM5500, ACM7000, CM7100, IM7200 or IM4200) then checking Enable TFTP (FTP) service will enable this service and set up default *tp and &p server on the USB flash. These servers are used to store config files, maintain access and transac!on logs etc. Files transferred using tftp and ftp will be stored under /var/mnt/storage.usb/ tftpboot/ (or /var/mnt/storage.nvlog/tftpboot/ on ACM7000-series devices). Unchecking Enable TFTP (FTP) service will completely disable the TFTP (FTP) service. · DNS Relay Checking Enable DNS Server/Relay will enable the DNS relay feature so clients can be configured with the console server's IP for their DNS server se$ng, and the console server will forward the DNS queries to the real DNS server. · Web Terminal Checking Enable Web Terminal will allow web browser access to the system command line shell via Manage > Terminal. · Specify alternate port numbers for Raw TCP, direct Telnet/SSH and unauthen!cated Telnet/SSH services. The console server uses specific default ranges for the TCP/IP ports for the various access services that Users and Administrators can use to access devices a%ached to serial ports (see chapter 3, `Serial port, host, device & user configura!on'). The Administrator can also set alternate ranges for these services, and these secondary ports will then be used in addi!on to the defaults. The default TCP/IP base port address for telnet access is 2000, and the range for telnet is IP Address: Port (2000 + serial port #), thais is ports 2001 2048. For example, if the Administrator sets 8000 as a secondary base for telnet then serial port #2 on the console server can be accessed via telnet at IP Address:2002 and at IP Address:8002. The default base for SSH is 3000; for Raw TCP the default base is 4000; and for RFC2217 it is 5000. A number of other services can be enabled and configured indirectly from this menu by selec!ng Click here to configure: · Nagios Access to the Nagios NRPE monitoring daemons (see chapter 9). · NUT Access to the NUT UPS monitoring daemon (see chapter 10). · SNMP This will enable netsnmp in the console server. SNMP is disabled by default (see chapter 6 and chapter 14.5). Opengear User Manual. Page 38. · NTP See chapter 10. · Click Apply. As you apply your services selec!ons, the screen will be updated with a confirma!on message: Message Changes to configura"on succeeded. The Services Access se$ngs can now be set to allow or block access. This specifies which (enabled) services the Administrator can use over each network interface to connect to the console server and, through the console server, to a%ached serial and network connected devices. · Navigate to System > Services. · Select the Service Access tab. Note: With firmware releases pre 3.5.3 the Service Access tab is found at System > Firewall. The services currently enabled for the console server's network interfaces present. Depending on the par!cular console server model the interfaces displayed may include : Network interface for the principal Ethernet connec!on). Management LAN/OOB Failover second Ethernet connec!ons). Dialout/Cellular V90 and 3G modem. Dial-in internal or external V90 modem. Wi-Fi VPN 802.11 wireless. IPsec or Open VPN connec!on over any network interface. Opengear User Manual. Page 39. · Check or uncheck for each network to which service access is to be enabled or disabled. In the example shown below, local administrators on the local Management LAN have telnet access direct to the console server (and a%ached serial ports) while remote administrators using Dial-In or Cellular have no telnet access (unless they set up a VPN). · The Respond to ICMP echos (that is ping) service access op!ons can be configured at this stage. This allows the console server to respond to incoming ICMP echo requests. ping is enabled by default. For security reasons, however, this service should generally be disabled post ini!al configura!on. · You can also configure to allow serial port devices to be accessed from nominated network interfaces using Raw TCP, direct Telnet/SSH, unauthen!cated Telnet/SSH services, etc. · Click Apply to apply your services access selec!ons. 2.4.1. Brute force protec"on Brute force protec"on (Micro Fail2ban) temporarily blocks source IPs that show malicious signs, such as too many password failures. This may help mi!gate scenarios where the Opengear device's network services are exposed to an untrusted network such as the public WAN, and scripted a%acks or so&ware worms are a%emp!ng to guess (brute force) user creden!als and gain unauthorized access. Opengear User Manual. Page 40. Brute force protec"on may be enabled for the listed services. Once protec!on is enabled, 3 or more failed connec!on a%empts within 60 seconds from a specific source IP trigger it to be banned from connec!ng for the next 60 seconds. Ac!ve Bans are also listed and may be refreshed by reloading the page. Note: When an Opengear device is running on an untrusted network, it is recommended that a variety of strategies are used to lock down remote access. This includes strong passwords (or even be"er, SSH public key authen#ca#on), VPN, and using Firewall Rules to whitelist remote access from trusted source networks only. Please refer to the Knowledge Base for details. 2.5. Communica"ons so!ware You have configured access protocols for the Administrator client to use when connec!ng to the console server. User clients (which may be set up later) will also use these protocols when accessing console server serial a%ached devices and network a%ached hosts. So you will need to have appropriate communica!ons so&ware tools set up on the Administrator (and User) client's computer. Opengear provides the SDT Connector as the recommended client so&ware tool. Other generic tools such as PuTTY and SSHTerm may be used, however, and these are all described below. 2.5.1. SDT connector SDT Connector is a lightweight tool that enables Users and Administrators to securely access the Console server, and the various computers, network devices and appliances that may be serially or network connected to the console server. SDT Connector is a Java client program that couples the trusted SSH tunneling protocol with popular access tools such as Telnet, SSH, HTTP, HTTPS, VNC, and RDP to provide point-andclick secure remote management access to all the managed systems and devices. Informa!on on using SDT Connector for browser access to the console server's Management Console, Telnet/SSH access to the console server command line, and TCP/UDP connec!ng to hosts that are network connected to the console server can be found in chapter 5, SSH tunnels & SDT connector. Opengear User Manual. Page 41. SDT Connector can be installed on computers running Windows or macOS and on most Linux, UNIX and Solaris systems. 2.5.2. PuTTY Communica!ons packages like PuTTY can be also used to connect to the Console server command line (and to connect serially a%ached devices as covered in chapter 3). PuTTY is a freeware implementa!on of Telnet and SSH for Win32 and UNIX pla*orms. It runs as an executable applica!on without needing to be installed onto your system. PuTTY (the Telnet and SSH client itself) can be downloaded from h%p://pu%y.org/. To use PuTTY for an SSH terminal session from a Windows client, you enter the console server's IP address as the `Host Name (or IP address)'. To access the console server command line you select `SSH' as the protocol, and use the default IP Port 22. Click `Open' and you will be presented with the console server login prompt. (You may also receive a `Security Alert' that the host's key is not cached, you will need to choose `yes' to con!nue.) Using the Telnet protocol is similarly simple, except you use the default telnet port: port 23. 2.5.3. SSHTerm Another communica!ons package that may be useful is SSHTerm, an open source package that can be downloaded from h%p://sourceforge.net/projects/sshtools. · To use SSHTerm for an SSH terminal session from a Windows client, Select File > New Connec"on. ·A dialog box appears for your Connec"on Profile. ·Enter the host name or IP address for the console server you are connec!ng to and the TCP port that the SSH session will use (port 22). · ·Enter your username, choose password authen!ca!on, and click Connect. ·If you receive a message about the host key fingerprint, select Yes or Always to con!nue. ·The remote system will prompt you for a username and password. Enter these to login to the console server. Opengear User Manual. Page 42. 2.6. Management network configura"on The IM4200, IM7200, CM7100, ACM5500, ACM7000 and ACM5004-2 console servers have additional network ports that can be configured to provide management LAN access and/or failover or out-of-band access. 2.6.1. Enable the management LAN The IM4200, IM7200, CM7100, ACM7000, ACM5508-2-I/M and ACM5004-2 console servers can be configured so the second Ethernet port provides a management LAN gateway. The gateway has firewall, router and DHCP server features. However you need to connect an external LAN switch to Network/LAN 2 to a%ach hosts to this management LAN: Note: The second ethernet port (Network/LAN2) on the IM4200, IM7200, CM7100, ACM7000, ACM5508-2-I/M and ACM5004-2 can be configured as either a Management LAN gateway port or it can be configured as an OOB/Failover port. It cannot be both. Do not allocate Network/LAN 2 as the Failover Interface when you configured the principal Network connec#on on the System > IP menu. The ACM5504-5-G-I, ACM5504-5-LA/LR/LV-I, ACM5504-5-G-W-I and IM4216-34 console server models have integrated four or thirty-two port management LAN switches (with firewall, router, DHCP server and switch func!ons). Opengear User Manual. Page 43. The IM4216-34 is normally configured with an ac!ve 32-port Management LAN (Ethernet 1-32) switch and Network 2 configured for OOB or Failover. The ACM5504-5-G-W-I and ACM5504-5-G-I is normally configured with an ac!ve Management LAN. This can be a 4 port (ETH1-4) Management LAN switch, or a 3 port (ETH2-4) switch with ETH 1 configured for OOB/Failover. Management LAN features are disabled by default. To configure a Management LAN gateway: · Navigate to System > IP. · Select the Management LAN Interface tab. · Uncheck Disable. · Configure the IP Address and Subnet Mask for the Management LAN. Leave the DNS fields blank. · Click Apply. The management gateway func!on is now enabled with default firewall and router rules. By default these rules are configured so the Management LAN can only be accessible by SSH port forwarding. This ensures the remote and local connec!ons to Managed Devices on the Management LAN are secure. The LAN ports can also be configured in bridged or bonded mode (as described later in this chapter) or they can be manually configured from the command line. 2.6.2. Configure the DHCP server All IM and ACM family devices host a DHCP server. It is, however, disabled by default. The DHCP server enables the automa!c distribu!on of IP addresses to devices on the Opengear User Manual. Page 44. Management LAN that are running DHCP clients. To enable the DHCP server: · Navigate to System > IP. · Select the Management LAN Interface tab. · Check the Enable DHCP Server checkbox. · Enter the Gateway address to be issued to DHCP clients. If this field is le& blank, the console server's IP address will be used. · Enter the Primary DNS and Secondary DNS address to be issued to DHCP clients. Again if this field is le& blank, the console server's IP address is used. For automa!c DNS server assignment, leave this field blank. · Enter a Domain Name suffix to issue DHCP clients. This is an op!onal value and step. · Enter the Default Lease !me and Maximum Lease !me in seconds. The lease !me is the !me that a dynamically assigned IP address is valid before the client must request it again. · Click Apply. The DHCP server will sequen!ally issue IP addresses from the specified address pool or pools: · Click Add in the Dynamic Address Alloca"on Pools field. · Enter the DHCP Pool Start Address and End Address. Opengear User Manual. Page 45. · Click Apply. The DHCP server also supports pre-assigning IP addresses to be allocated only to specific MAC addresses and reserving IP addresses to be used by connected hosts with fixed IP addresses. To reserve an IP addresses for a par!cular host: · Click Add in the Reserved Addresses field. · Enter the Hostname, the Hardware Address (MAC) and the Sta"cally Reserved IP address for the DHCP client. · Click Apply. When DHCP has ini!ally allocated hosts addresses it is recommended to copy these into the pre-assigned list so the same IP address will be reallocated in the event of a reboot. 2.6.3. Select failover or broadband OOP The IM4200, IM7200, CM7100, ACM7000, ACM5508-2-I/M, ACM5504-5-G-W-I, ACM5504-5-G-I, ACM5504-5-LA/LR/LV-I, and ACM5004-2 console servers provide a failover op!on so in the event of a problem using the main LAN connec!on for accessing the console server; an alternate access path is used. By default the failover is not enabled. To enable: · Navigate to System > IP. · Select the Network tab. · Select the Failover Interface to be used in the event of an outage on the main network. This can be: an alternate broadband Ethernet connec!on (for example, the Network/LAN2 port on most models) or the IM4200 or IM7200 family internal modem or an external serial modem device connected to the IM4200 or IM7200 Console port (for out-dialing to an ISP or the remote management office). Opengear User Manual. Page 46. · Click Apply. Note: The failover method is not ac#ve un#l the external sites to be probed to trigger failover are specified and the failover ports themselves are set-up. This is covered in Chapter 4. Note: The ACM5504-5-G(-W)-I and IM4216-34 can be configured with an ac#ve Management LAN/gateway and with one of the switched Ethernet ports configured for OOB/Failover (ETH 1 on the ACM5504-5-G(-W)-I or NETWORK 2 on the IM4216-34). On the other IM4200, IM7200, CM7100, ACM7000, ACM5508-2 and ACM5004-2 models, the second Ethernet port can be configured as either a gateway port or as an OOB/Failover port, but not both. 2.6.4. Aggrega"ng the network ports By default the console server's Management LAN network ports can only be accessed using SSH tunneling/port forwarding or by establishing an IPsec VPN tunnel to the console server. However all the wired network ports on the console servers can be aggregated by being bridged or bonded. · Navigate to System > IP. · Click the General Se!ngs tab. · Click the Bridge Interfaces or Bond Interfaces radio bu%on to enable wired Ethernet interface aggrega!on. When bridging is enabled, network traffic is forwarded across all Ethernet ports with no firewall restric!ons. All Ethernet ports are transparently connected at the data link layer (layer 2) so they do retain their unique MAC addresses, however. With bonding, the network traffic is carried between the ports but they present with one MAC address. Both modes remove all the Management LAN Interface and Out-of-Band/Failover Interface func!ons and disable the DHCP Server. Opengear User Manual. Page 47. Note: In aggrega#on mode all the Ethernet ports are configured collec#vely via the System > IP > Network Interface tab. 2.6.5. Wi-Fi wireless LAN All IM7200 models and the ACM5504-5-G-W-I have an internal 802.11 Wi-Fi adapter and come with an external Wi-Fi antenna. The Wi-Fi can be configured as a Wi-Fi Wireless Access Point (WAP) or as a Wi-Fi client. The inbuilt Wi-Fi is inac!ve by default. If you wish to use the Wi-Fi facility you will need to a%ach the Wi-Fi antenna (and any auxiliary Wi-Fi antenna you may have ordered). To ac!vate and configure the Wireless Access Point func!onality: · Navigate to System > IP. · Click the Wireless Network Interface tab. · Uncheck the Disable check-box. · Select the device's opera!ng mode: Wireless Client or Wireless AP (for Access Point). If Wireless AP is checked the Wireless AP Se!ngs sec!on becomes visible. Opengear User Manual. Page 48. · Set the IP Address, and the netmask in the IP Se#ngs for the Wireless Network. Generally, if the device is being used as a Wireless AP, a sta!c address is set here. In the example below, 192.168.10.1 is used. As well, in the example below, the netmask is set to 255.255.255.0 to give 254 unique network addresses in the subnet. · Do not fill in the Gateway, Primary DNS and Secondary DNS values. These se$ngs are used if the interface is to be the primary network link to the outside world, or if it will be used for failover. · Select the correct country from the Country list. If the correct country is not listed, select the World Regulatory Domain. · Select an SSID for the network. This should be unique. · Check the Broadcast SSID check box. This should, in general, be done. Not broadcas!ng a wireless network's SSID is not a meaningful security measure. · Select the Network Channel. The most commonly used channel is 6. Note: if the unit is being deployed in an environment containing mul#ple Wireless APs (eg a mul#- floor office building), a site survey, to establish what channels are locally unused is recommended. · Select the unit's Hardware Mode. The unit supports 802.11b, 802.11g, and single band 802.11n. In most cases, selec!ng 802.11b/g/n will provide for the best interoperability with other hardware. · Select the Supported Authen"ca"on Methods. WPA/WPA2 with AES encryp!on is recommended. WEP and WPA with TKIP have been proven vulnerable to cryptanalysis a%ack. Only select these la%er authen!ca!on methods if you must support client equipment that does not support WPA/WPA2 with AES. If WPA/WPA2 is the selected Supported Authen"ca"on Method. · Select one or both of TKIP and AES in WPA/WPA2 Encryp"on Methods. As noted above, AES is more secure. It is also required for a Wireless AP to adver!se itself as 802.11n if that is the selected Hardware Mode. If WEP is the selected Supported Authen"ca"on Method. · Select either Open System or Shared System in the WEP Mode. Note: while Open System is more secure than Shared System (due to the way encryp#on keys are used), known vulnerabili#es mean WEP cannot be considered secure in any sense. · click Apply and wait for the page to refresh. Opengear User Manual. Page 49. The next step is to set up a DHCP server for the wireless clients. Click the link next to DHCP Server in the IP se$ngs sec!on, or go to System > DHCP Server. More informa!on on configuring DHCP can be found in chapter 2.6.2. If Wireless Client is checked the Wireless Client Se!ngs sec!on becomes visible. · Select DHCP or Sta"c for the Configura"on Method. If Sta"c is selected, manually enter the new IP Address, Subnet Mask, Gateway and DNS server details. This selec!on automa!cally disables the DHCP client. If DHCP is selected, the device will look for configura!on details from a DHCP server on your management LAN. This selec!on automa!cally disables any sta!c address. Note: the device's MAC address can be found on a label on the base plate. Configure the Wireless client to select the local wireless network which will serve as the main network connec!on to the console server. · Select the correct country from the Country list. Opengear User Manual. Page 50. If the correct country is not listed, select the World Regulatory Domain. · Enter the SSID (Set Service Iden!fier) of the wireless access point the Wireless Client will connect to. · Select the Wireless Network Type. Select Infrastructure to connect to a Wireless AP device. Select Ad-hoc to connect directly to a computer. · Select the Wireless Security mode of the wireless network (WEP, WPA, etc) · Enter the required authen!ca!on strings. When enabled in client mode, the wireless LAN will operate as the main network connec!on to the device so failover is available (though it not enabled by default). Use Failover Interface to select the device to failover to in case of wireless outage and specify Probe Addresses of the peers to probed for connec!vity detec!on. Note: The Wireless screen in Status > Sta"s"cs will display all the locally accessible wireless LANs (with SSID and Encryp#on/Authen#ca#on se&ngs). You can also use this screen to confirm you have successfully connected to the selected access point. See chapter 11 for more. 2.6.6. Sta"c routes Firmware 3.4 and later support sta"c routes which provide a quick way to route data from one subnet to different subnet. You can hard code a path that specifies to the console server or router to get to a certain subnet by using a certain path. This may be useful for remotely accessing various subnets at a remote site when being accessed using the cellular OOB connec!on. To add a sta!c route to the route table of the system: · Navigate to System > IP > General Se!ngs. · Select the Route Se!ngs tab. · Enter a meaningful Route Name for the route. · In the Des"na"on Network/Host field, enter the IP address of the des!na!on network or host that the route provides access to. Opengear User Manual. Page 51. · Enter a value in the Des"na"on netmask field that iden!fies the des!na!on network or host. Any number between 0 and 32. A subnet mask of 32 iden!fies a host route. · Fill the Route Gateway field with the IP address of a router that will route packets to the des!na!on network. This field may be le& blank, depending on your network configura!on. · Select the Interface to use to reach the des!na!on This field may be le& as None. · Enter a value in the Metric field that represents the metric of this connec!on. This generally only has to be set if two or more routes conflict or have overlapping targets. Any number equal to or greater than 0. · Click Apply. Note: The route details page provides a list of network interfaces and modems to which a route can be bound. In the case of a modem, the route will be a"ached to any dialup session which is establish via that device. A route can be specified with a gateway, an interface or both. If the specified interface is not ac#ve for whatever reason, then routes configured for that interface will not be ac#ve. Opengear User Manual. Page 52. 3.Serial port, host, device & user configura!on The console server enables access and control of serially-a%ached devices and networka%ached devices (hosts). The Administrator must configure access privileges for each of these devices, and specify the services that can be used to control the devices. The Administrator can also set up new users and specify each user's individual access and control privileges. This chapter covers each of the steps in configuring network-connected and serially-a%ached devices: step Serial ports Users & Groups notes se$ng up serially connected device protocols. se$ng up and defining user access permissions. Opengear User Manual. Page 53. Authen!ca!on also covered in more detail in Chapter 8. Network hosts configuring access to network-connected hosts. Configuring trusted networks nominate IP addresses trusted users access from. Serial console port cascading & redirec!on Power (UPS, PDU & IPMI) Environmental Monitoring Devices (EMD) Serial port redirec!on the PortShare client on Windows and Linux. Managed devices the consolidated view of all the connec!ons. IPSec enabling VPN connec!ons. OpenVPN PPTP 3.1. Configure serial ports The first step in configuring a serial port is to set the Common Se!ngs such as the protocols and the RS232 parameters that are to be used for the data connec!on to that port (for example, baud rate). Then you select what mode the port is to operate in. Each port can be set to support one of these opera!ng modes: mode notes Disabled The serial port is inac!ve. Console server enables general access to serial console port on the serially a%ached devices. Device sets the serial port up to communicate with an intelligent serial controlled PDU, UPS or Environmental Monitor Devices (EMD). SDT enables graphical console access (with RDP, VNC, HTTPS etc.) to hosts that are serially connected. Terminal server sets the serial port to await an incoming terminal login session. Serial bridge enables the transparent interconnec!on of two serial port devices over a network. Opengear User Manual. Page 54. · Navigate to Serial & Network > Serial Port. Details of the currently setup serial ports presents. By default, each serial port is set in console server mode. · Click Edit to reconfigure a given serial port. · Reconfigure the common se$ngs (chapter 3.1.1) and the mode (chapters 3.1.2 3.1.6) for each port as needed. · Set up any remote syslog (chapter 3.1.7). · click Apply. Note: to set the same protocol op#ons for mul#ple serial ports at once click Edit Mul"ple Ports and select which ports you wish to configure as a group. · if the console server has been configured with distributed Nagios monitoring enabled then you will also be presented with Nagios Se!ngs op!ons to enable nominated services on the host to be monitored (see chapter 9). 3.1.1. Common se&ngs There are a number of common se$ngs that can be set for each serial port. These are independent of the mode in which the port is being used. These serial port parameters must be set so they match the serial port parameters on the device you a%ach to that port. · Specify a Label for the port. · Select the appropriate Baud Rate, Parity, Data Bits, Stop Bits and Flow Control for each port. · Set the Signaling Protocol. This menu item only presents in ports with RS422/485 op!ons (all ports on ACM5004-2-I, ACM5508-2-I, ACM5504-5-LA/LR/LV-I and ACM5504-5-G-I). The op!ons available are RS232, RS422, RS485 and RS485 Echo mode. · Set the Port Pinout. This menu item only presents for IM7200 ports where pin-out for each RJ45 serial port can be set as either X2 (Cisco Straight) or X1 (Cisco Rolled). · Before proceeding with further serial port configura!on, you should connect the ports to the serial devices they will be controlling, and ensure they have matching se$ngs. Opengear User Manual. Page 55. 3.1.2. Console server mode · Select Console Server Mode to enable remote management access to the serial console that is a%ached to this serial port. · Set the desired Logging Level. This specifies the level of informa!on to be logged and monitored (see chapter 6). · Enable or disble Telnet access. When the Telnet service is enabled on the console server, a Telnet client on a User's or Administrator's computer can connect to a serial device a%ached to this serial port on the console server. Telnet communica!ons are unencrypted so this protocol is generally recommended only for local or VPN-tunneled connec!ons. Windows 2000, Windows XP and Windows NT can run telnet from the cmd.exe command prompt. Windows Vista and later ship with a Telnet client but it is not enabled by default. You can install it as follows. · Click the Start bu%on. Opengear User Manual. Page 56. · Click Control Panel. · Click Programs. · Click Turn Windows features on or off. If you are prompted for an administrator password or confirma!on, type the password or provide confirma!on. · In the Windows Features dialog box, select the Telnet Client check box. · Click OK. The installa!on may take several minutes. If remote communica!ons are being tunneled with SDT Connector, then Telnet can be used for securely accessing these a%ached devices. Note: In Console Server mode, Users and Administrators can use SDT Connector to set up secure Telnet connec#ons that are SSH tunneled from their client computers to the serial port on the console server. SDT Connector can be installed on Windows PCs and on most Linux pla'orms and it enables secure Telnet connec#ons to be selected with a simple pointand-click. To use SDT Connector to access consoles on the console server serial ports, you configure SDT Connector with the console server as a gateway, then as a host, and you enable Telnet service on Port 2000 + serial port # (that is Ports 20012048). See chapter 5 for more details on using SDT Connector for Telnet and SSH access to devices that are a"ached to the console server serial ports. You can also use communica!ons packages like PuTTY to set a direct Telnet (or SSH) connec!on to the serial ports. Note: PuTTY supports Telnet (and SSH). Enter the console server's IP address as the Host Name (or IP address). Select Telnet as the protocol and set the TCP port to 2000 plus the Opengear User Manual. Page 57. physical serial port number (that is a port between 2001 and 2048). Click the Open bu"on. You may receive a Security Alert that the host's key is not cached: choose yes to con#nue. The login prompt of the remote system connected to the serial port chosen on the console server will now present. You can login as normal and use the host serial console screen. Pu%y can be downloaded from h%p://pu%y.org/. Note: In Console Server mode, when you connect to a serial port you connect via pmshell. To generate a BREAK on the serial port type the character sequence ~b. If you're doing this over OpenSSH type ~~b. · Enable or disable SSH access. It is recommended you use SSH as the protocol where the User or Administrator connects to the console server (or connects through the console server to the a%ached serial consoles) over the Internet or any other public network. This will provide authen!cated SSH communica!ons between the SSH client program on the remote user's computer and the console server, so the user's communica!on with the serial device a%ached to the console server is secure For SSH access to the consoles on devices a%ached to the console server serial ports, you can use SDT Connector. You configure SDT Connector with the console server as a gateway, then as a host, and you enable SSH service on Port 3000 + serial port #. (That is ports 3001 3048). See chapter 5 for more informa!on on using SDT Connector for SSH access to devices that are a%ached to the console server serial ports. Also you can use common communica!ons packages, like PuTTY or SSHTerm to SSH connect directly to port address IP Address:Port 3000 + serial port #. (That is ports 3001 3048). Alternately SSH connec!ons can be configured using the standard SSH port 22. The serial port being accessed is then iden!fied by appending a descriptor to the username. This syntax supports any of the following descriptors: <username>:<portXX> <username>:<port-label> <username>:<ttySX> <username>:<serial> For example, if a User named fred wants to access serial port 2, when se$ng up SSHTerm or the PuTTY SSH client, instead of typing username = fred ssh port = 3002 type username = fred:port02 or username = fred:ttyS1 and ssh port = 22. Opengear User Manual. Page 58. Alterna!vely, by typing username=fred:serial and ssh port = 22 the User is presented with a port selec!on op!on This syntax enables Users to set up SSH tunnels to all serial ports with only a single IP port 22 having to be opened in their firewall or gateway. Note: In Console Server mode, when you connect to a serial port you connect via pmshell. To generate a BREAK on the serial port type the character sequence ~b. If you're doing this over OpenSSH type ~~b. · Enable or disable Raw TCP access. RAW TCP allows connec!ons directly to a TCP socket. Communica!ons programs like PuTTY support RAW TCP. This protocol, however, would usually be used by a custom applica!on For RAW TCP, the default port address is IP Address:Port 4000 + serial port # (That is ports 4001 4048). RAW TCP also enables the serial port to be tunneled to a remote console server, so two serial port devices can be transparently interconnect over a network (see chapter 3.1.6). · Enable or disable RFC 2217 access. Enabling RFC 2217 access enables serial port redirec!on on that port. For RFC 2217, the default port address is IP Address:Port 5000 + serial port # (that is Port #s 5001 5048). Special client so&ware is available for Windows UNIX and Linux that supports RFC 2217 virtual com ports, so a remote host can monitor and manage remote serially a%ached devices, as though they were connected to the local serial port (see chapter 3.6 for details). RFC 2217 also enables the serial port to be tunneled to a remote console server, so two serial port devices can be transparently interconnect over a network (see chapter 3.1.6). · Enable or disable Unauthen"cated Telnet. Enabling Unauthen"cated Telnet enables telnet access to the serial port without authen!ca!on creden!als. When a user accesses the console server to telnet to a serial port, they are normally given a login prompt. However with unauthen!cated telnet they connect directly through to the port without any console server login challenge. (If a telnet client does prompt for authen!ca!on, any entered data will allow connec!on.) Opengear User Manual. Page 59. This mode is mainly used when you have an external system (such as conserver) managing user authen!ca!on and access privileges at the serial device level. Note: only the connec#on to the console server is unauthen#cated. Logging into a device connected to the console server may s#ll require authen#ca#on. For Unauthen"cated Telnet the default port address is IP Address:Port 6000 + serial port # (that is Port #s 6001 6048). · Enable or disable Web Terminal. Enabling Web Terminal enables web browser access to the serial port via Manage > Devices > Serial using the Management Console's built in AJAX terminal. Web Terminal connects as the currently authen!cated Management Console user and does not re-authen!cate. See chapter 12.3 for more details. · Enter an IP Alias (aliasing for the Network Interface, Management LAN or Out-of-Band/ Failover). A working IP Alias, enables access to the serial port using a specific IP address, specified in CIDR format. Each serial port can be assigned one or more IP aliases, configured on a pernetwork-interface basis. A serial port can, for example, be made accessible at both 192.168.0.148 (as part of the internal network) and 10.10.10.148 (as part of the Management LAN). It is also possible to make a serial port available on two IP addresses on the same network (for example, 192.168.0.148 and 192.168.0.248). These IP addresses can only be used to access the specific serial port, accessible using the standard protocol TCP port numbers of the console server services. For example, SSH on serial port 3 would be accessible on port 22 of a serial port IP alias (whereas on the console server's primary address it is available on port 2003). This feature can also be configured via the mul!ple port edit page. In this case the IP addresses are applied sequen!ally, with the first selected port ge$ng the IP entered and subsequent ones ge$ng incremented, with numbers being skipped for any unselected ports. For example if ports 2, 3 and 5 are selected and the IP alias 10.0.0.1/24 is entered for the Network Interface, the following addresses will be asssigned: Port 2: 10.0.0.1/24 Port 3: 10.0.0.2/24 Port 5: 10.0.0.4/24 · Enable or disable Encrypt Traffic and enable or disable Authen"cate. (These op!ons should be either enabled or disabled as a pair.) Enabling these two op!ons turns on trivial encryp!on and authen!ca!on of RFC2217 serial communica!ons using Portshare. For strong encryp!on use VPN. · Set an Accumula"on Period. Once a connec!on has been established for a par!cular serial port (such as a RFC2217 redirec!on or Telnet connec!on to a remote computer) any incoming characters on that port are forwarded over the network on a character by character basis. The accumula!on period changes this by specifying a period of !me that incoming characters will be Opengear User Manual. Page 60. collected before then being sent as a packet over the network. · Set a custom Escape Character. This enables you to change the character used for sending escape characters. The default is ~. · Enable or disable the Power Menu. This se$ng enables the shell power command so a user can control the power connec!on to a Managed Device from the command line when they are telnet- or ssh-connected to the device. To operate the Managed Device must be set up with both its Serial port connec!on and Power connec!on configured. The command to bring up the power menu is ~p. · Enable or disable Single Connec"on. Enabling this se$ng limits the port to a single connec!on. If this is enabled and mul!ple users have access privileges for a par!cular port, only one user at a !me can be accessing that port (that is, port snooping is not permi%ed). 3.1.3. SDT mode Opengear User Manual. Page 61. This Secure Tunneling se$ng allows port forwarding of RDP, VNC, HTPP, HTTPS, SSH, Telnet and other LAN protocols through to computers which are locally connected to the console server by their serial COM port. However such port forwarding requires a PPP link to be set up over this serial port. For configura!on details refer to chapter 5.6. 3.1.4. Device (RPC, UPS, EMD) mode This mode configures the selected serial port to communicate with a serial controlled Uninterruptable Power Supply (UPS), Remote Power Controller / Power Distribu!on Units (RPC) or Environmental Monitoring Device (EMD). · Select the desired Device Type (UPS, RPC or EMD). · Proceed to the appropriate device configura!on page: Serial & Network > UPS Connec"ons, RPC Connec"on or Environmental) as detailed in chapter 7. 3.1.5. Terminal server mode · Enable Terminal Server Mode and set the Terminal Type (vt220, vt102, vt100, Linux or ANSI) to enable a ge$y on the selected serial port. The ge$y will then configure the port and wait for a connec!on to be made. An ac!ve connec!on on a serial device is usually indicated by the Data Carrier Detect (DCD) pin on the serial device being raised. When a connec!on is detected, the ge%y program issues a login: prompt, and then invokes the login program to handle the actual system login. Note: Selec#ng Terminal Server mode will disable Port Manager for that serial port, so data is no longer logged for alerts etc. Opengear User Manual. Page 62. 3.1.6. Serial bridging mode With serial bridging, the serial data on a nominated serial port on one console server is encapsulated into network packets and then transported over a network to a second console server where is then represented as serial data. So the two console servers effec!vely act as a virtual serial cable over an IP network. One console server is configured to be the Server. The Server serial port to be bridged is set in Console Server mode with either RFC2217 or RAW enabled (as described in chapter 3.1.2). For the Client console server, the serial port to be bridged must be set in Bridging Mode. · Enable Serial Bridging Mode and specify the IP address of the Server console server and the TCP port address of the remote serial port (for RFC2217 bridging this will be 5001-5048). · By default the bridging client will use RAW TCP so you must select RFC2217 if this is the console Server mode you have specified on the server console server. · You may secure the communica!ons over the local Ethernet by enabling SSH however you will need to generate and upload keys (see chapter 14). 3.1.7. Syslog In addi!on to inbuilt logging and monitoring (which can be applied to serial-a%ached and network-a%ached management accesses, as covered in chapter 6) the console server can also be configured to support the remote syslog protocol on a per serial port basis. · Select the Syslog Facility and Syslog Priority fields to enable logging of traffic on the selected serial port to a syslog server and to appropriately sort and ac!on those logged messages (for example, redirect them or send an alert email). For example if the computer a%ached to serial port 3 should never send anything out on its Opengear User Manual. Page 63. serial console port, the Administrator can set the Syslog Facility for that port to local0 (local0 local7 are meant for site local values), and the Syslog Priority to cri!cal. At this priority, if the console server syslog server does receive a message, it will automa!cally raise an alert. See chapter 6 for more. 3.1.8. NMEA streaming The ACM5004-G-I, ACM5504-5-G(-W)-I, ACM5504-5-LA/LR/LV-I, ACM7000-L and IM4200-G can provide GPS NMEA data streaming from the internal GPS /cellular modem. This data stream presents as a serial data stream on port 5 on the ACM models. For the IM4200-G with an internal cellular modem, the NMEA data stream presents on ports 9/17/33/49 for the IM4208/16/32/48 models. The Common Se$ngs (baud rate etc.) are ignored when configuring the NMEA "serial port". However you can specify the Fix Frequency (i.e. this GPS fix rate determines how o&en GPS fixes are obtained). You can also apply all the Console Server Mode, Syslog and Serial Bridging se$ngs to this port. Note: The NMEA Streaming menu item should display on the Serial & Network > Serial Port menu. However for earlier revision ACM5004-G-I units you may need to update the se'set se&ngs from the command line. setfset -r lists all of the current feature set variables. You look for the factory_opts variable, and then add 3g-gps to it. For example, factory_opts=rs485,3g,ind. To update it to 3g-gps, you do the following: setfset -u factory_opts=rs485,3g-gps,ind. Then run setfset -r again, and make sure you can see the update. You can use pmshell, webshell, SSH, RFC2217 or RawTCP to get at the stream: Opengear User Manual. Page 64. For example, using the Web Terminal: Note: This GPS support is also available for IM4200-G with an internal cellular modem. The NMEA data stream presents on ports 9/17/33/49 for the IM4208/16/32/48 models. 3.1.9. Cisco USB console connec"on The ACM5000-, ACM5500-, and IM4200-family console servers support direct USB 2.0 connec!on to one or two Cisco USB console ports (in addi!on to the tradi!onal RS-232 serial console port connec!ons). With such a USB console connec!on, users can send IOS commands through the USB console port remotely (using a browser and the console server's built-in AJAX terminal) or monitor messages from the Cisco USB console ports and take rule book ac!ons (using the console server's built-in Auto-Response capabili!es). For configura!on and control, these USB consoles are presented as new "serial ports". For example, on an ACM5504-5-G with cellular GPS configured on Port 5 (as shown above), any Cisco USB console ports would present as Port 6 and 7. For the IM4200-series (without any internal GPS modem func!ons) any configured Cisco USB console ports would present as follows: ports 19 & 10 on the IM4208. ports 17 & 18 on the IM4216. ports 33 & 34 on the IM4232. ports 49 & 50 on the IM4248. The Common Se$ngs (baud rate etc) are ignored when configuring the Cisco USB "serial port". However you can apply all the Console Server Mode, Syslog and Serial Bridging se$ngs to this port. Opengear User Manual. Page 65. Note: The Cisco USB console must be manually configured on ini#al connec#on. However any USB console disconnec#on is auto-detected. USB console re-connec#on on the same physical USB port will also be auto-detected, but only if the console server has been power cycled. 3.1.10. USB consoles Opengear ACM7000, CM7100 and IM7200 family console servers running firmware 3.16.5 or later support USB console connec!ons to devices from a wide range of vendors, including Cisco, HP, Dell and Brocade. Moreover, and aside from their u!lity as USB connec!ons, all the USB ports on these console servers can func!on as plain RS-232 serial ports when a USB-toserial adapter is connected. These USB ports are available as regular portmanager ports and are presented numerically in the web UI a&er all RJ45 serial ports. The ACM7008-2, for example, has eight RJ45 serial ports on the rear of the console server and four USB ports on the front. In Serial & Network > Serial Port these are listed as port # connector 1 RJ45 2 RJ45 3 RJ45 4 RJ45 5 RJ45 6 RJ45 7 RJ45 8 RJ45 9 USB 10 USB 11 USB 12 USB If the par!cular ACM7008-2 is a cellular model, port #13 -- for the GPS -- will also be listed. As a further example, consider the 7216-24U. It has 16 RJ45 serial ports and 24 USB ports on its rear-face as well as two front-facing USB ports and (in the cellular model) a GPS. The RJ45 serial ports are presented in Serial & Network > Serial Port as port numbers 116. Opengear User Manual. Page 66. The 24 rear-facing USB ports take port numbers 1740, and the front-facing USB ports are listed at port numbers 41 and 42 respec!vely. And, as with the ACM7008-2, if the par!cular 7216-24U is a cellular model, the GPS is presented at port number 43. The common se$ngs (baud rate etc.) are used when configuring the ports, but some opera!ons (for example, sending serial breaks) may not work depending on the implementa!on of the underlying USB serial chip. 3.1.11. Link layer discovery protocol (LLDP) The Link Layer Discovery Protocol (LLDP) is a protocol that allows system administrators to glean informa!on about devices physically connected to managed switches. It is available for use on IM7200, CM7100 and ACM7000 devices. The LLDP service is enabled through the System > Services page. When the service is enabled, the lldpd daemon is loaded and runs. The Service Access tab controls which network interfaces are monitored by the lldpd daemon. When LLDP is granted access to an interface, it will use that interface even if the interface has been disabled via System > IP. LLDP neighbors are visible through the Status > LLDP Neighbors page. This page shows neighbors heard, and also indicates the informa!on that the console manager is sending. Note: although the LLDP service can be granted access to non-ethernet interfaces (for example, G3, G4 and PSTN dial-up interfaces), it currently ignores non-ethernet interfaces. The lldpcli shell client interacts with and configures the running LLDP service. Persistent custom configura!on changes can be added to the system through configura!on files placed in /etc/config/lldpd.d/. Custom configura!on files -- which must have filenames ending with .conf -- will be read and executed by lldpcli when the LLDP service starts. The /etc/ directory is read-only on Opengear hardware. Most default configura!on files otherwise stored in /etc/ are, on Opengear hardware, in /etc/config/, which is writeable. The default lldpd configura!on file -- lldpd.conf -- is stored in /etc/config/ on Opengear hardware. It is not safe as a store of custom configura!on details, however. There are circumstances in which this file is regenerated automa!cally, in which case all customisa!ons will be lost. The etc/config/lldpd.d/ directory, which is also writable and which is created on first boot, is safe to write to. Any Custom LLDP configura!ons must be stored as *.conf files in this directory. When enabled, LLDP frames issued by an Opengear Console Manager will reveal sensi!ve informa!on such as hostname, and firmware version. However, LLDP frames are not passed through by 802.3ab compliant switches, and Opengear Console Managers have the LLDP service disabled by default. Both lldpd and lldpcli have standard man pages but, because of space concerns, these pages are not shipped with Opengear hardware. Opengear User Manual. Page 67. Both man pages are available on the lldpd project web-site however: man lldpd is at h%ps:// vincentbernat.github.io/lldpd/usage.html#lldpd8; and man lldpcli is at h%ps:// vincentbernat.github.io/lldpd/usage.html#lldpcli8. Note: Opengear uses lldpd 0.9.2. 3.1.12. Configura"on over DHCP (ZTP) Config-over-DHCP is available for all Opengear console managers running firmware release 3.16 or later. Using this feature, Opengear devices can be provisioned during their ini!al boot from a DHCP server. Provisioning on untrusted networks can be facilitated by providing keys on a USB flash drive. The typical steps for configura!on over a trusted network are: · Manually configure a same-model Opengear device. · Save its configura!on as an Opengear backup (.opg) file. · Select System > Configura"on Backup > Remote Backup. · Click Save Backup. A backup configura!on file -- model-name_iso-format-date_config.opg -- is downloaded from the Opengear device to the local system. Alterna!vely, you can save the configura!on as an xml file: · Select System > Configura"on Backup > XML Configura"on. An editable field containing the configura!on file in XML format is presented. · Click into the field to make it ac!ve. · If you are running any browser on Windows or Linux, right-click and choose Select All from the contextual menu or press Control-A. Then right-click and choose Copy from the contextual menu or press Control-C. · If you are using any browser on macOS, choose Edit > Select All or press Command-A. Then choose Edit > Copy or press Command-C. · In your preferred text-editor, create a new empty document, paste the copied data into the empty document and save the file. Whatever file-name you choose, it must include the.xml filename suffix. · Copy the saved .opg or .xml file to a public-facing directory on a file server serving at least one of the following protocols: HTTPS, HTTP, FTP or TFTP. Note: Only HTTPS can be used if the connec#on between the file server and a to-be-configured Opengear device travels over an untrusted network. · Configure your DHCP server to include a `vendor specific' op!on for Opengear devices. (This will be done in a DHCP server-specific way.) The vendor specific op!on should be set to a string containing the URL of the published .opg or .xml file in the step above. The op!on string must not exceed 250 characters and it must end in either .opg or .xml. · Connect a new Opengear device (either factory-reset or Config-Erased) to the network and Opengear User Manual. Page 68. apply power. Note: it may take up to 5 minutes for the device to find the .opg or .xml file via DHCP, download and install the file and then reboot itself. Example ISC DHCP (dhcpd) server configura"on The following is an example DHCP server configura!on fragment for serving an .opg configura!on image via the ISC DHCP server, dhcpd: option space opengear code width 1 length width 1; option opengear.config-url code 1 = text; class "opengear-config-over-dhcp-test" { match if option vendor-class-identifier ~~ "^Opengear/"; vendor-option-space opengear; option opengear.config-url "https://example.com/opg/$ \ {class}.opg"; } Setup when the LAN is untrusted If the connec!on between the file server and a to-be-configured Opengear device includes an untrusted network, a two-handed approach can mi!gate the issue. Note: this approach introduces two physical steps where trust can be difficult, if not impossible, to establish completely. First, the custody chain from the crea#on of the data-carrying USB flash drive to its deployment. Second, the hands connec#ng the USB flash drive to the Opengear device. · Generate an X.509 cer!ficate for the Opengear device. · Concatenate the cer!ficate and its private key into a single file named client.pem. · Copy client.pem onto a USB flash drive. · Set up an HTTPS server such that access to the .opg or .xml file is restricted to clients that can provide the X.509 client cer!ficate generated above. · Put a copy of the CA cert that signed the HTTP server's cer!ficate -- ca-bundle.crt -- onto the USB flash drive bearing client.pem. · Insert the USB flash drive into the Opengear device before a%aching power or network. · Con!nue the procedure from `Copy the saved .opg or .xml file to a public-facing directory on a file server' above using the HTTPS protocol between the client and server. Prepare a USB drive and create the X.509 cer"ficate and private key · Generate the CA cer!ficate so the client and server Cer!ficate Signing Requests (CSRs) can be signed. # cp /etc/ssl/openssl.cnf . # mkdir -p exampleCA/newcerts # echo 00 > exampleCA/serial # echo 00 > exampleCA/crlnumber # touch exampleCA/index.txt # openssl genrsa -out ca.key 8192 Opengear User Manual. Page 69. # openssl req -new -x509 -days 3650 -key ca.key -out demoCA/ \cacert.pem -subj /CN=ExampleCA # cp demoCA/cacert.pem ca-bundle.crt Note: This procedure generates a cer#ficate called ExampleCA but any allowed cer#ficate name can be used. Also, this procedure uses openssl ca. If your organisa#on has an enterprisewide, secure CA genera#on process, that should be used instead. · Generate the client cer!ficate. # openssl genrsa -out client.key 4096 # openssl req -new -key client.key -out client.csr -subj \ /CN=ExampleClient # openssl ca -days 365 -in client.csr -out client.crt \ -keyfile ca.key -policy policy_anything -batch -notext # cat client.key client.crt > client.pem · Format a USB flash drive as a single FAT32 volume. · Move the client.pem and ca-bundle.crt files onto the flash drive's root directory. 3.2. Add & edit users The Administrator uses this menu selec!on to set up, edit and delete users and to define the access permissions for each of these users. Users can be authorized to access specified services, serial ports, power devices and specified network-a%ached hosts. These users can also be given full Administrator status (with full configura!on and management and access privileges). To simplify user set up, they can be configured as members of Groups. With firmware V3.5.2 and later there are six Groups set up by default (earlier versions only had admin and user by default): group admin descrip"on Provides users with unlimited configura!on and management privileges. Opengear User Manual. Page 70. pptpd dialin &p pmshell users Group to allow access to the PPTP VPN server. Users in this group will have their password stored in clear text. Group to allow access to the PPTP VPN server. Users in this group will have their password stored in clear text. Group to allow &p access and file access to storage devices. Group to set default shell to pmshell. Provides users with basic management privileges. Membership of the admin group provides the user with full Administrator privileges. The admin user (Administrator) can access the console server using any of the services which have been enabled in System: Services e.g. if only HTTPS has been enabled then the Administrator can only access the console server using HTTPS. However once logged in they can reconfigure the console server se$ngs (e.g. to enabled HTTP/Telnet for future access). They can also access any of the connected Hosts or serial port devices using any of the services that have been enabled for these connec!ons. But again the Administrator can reconfigure the access services for any Host or serial port. So only trusted users should have Administrator access Membership of the user group provides the user with limited access to the console server and connected Hosts and serial devices. These Users can access only the Management sec!on of the Management Console menu and they have no command line access to the console server. They also can only access those Hosts and serial devices that have been checked for them, using services that have been enabled If a user is set up with pptd, dialin, &p or pmshell group membership they will have restricted user shell access to the nominated managed devices but they will not have any direct access to the console server itself. To add this the users must also be a member of the "users" or "admin" groups The Administrator can also set up addi!onal Groups with specific power device, serial port and host access permissions. However users in these addi!onal groups don't have any access to the Management Console menu nor do they have any command line access to the console server itself. The Administrator can also set up users with specific power device, serial port and host access permissions, who are not a member of any Groups. Similarly these users don't have any access to the Management Console menu nor do they have any command line access to the console server itself. For convenience the SDT Connector "Retrieve Hosts" func!on retrieves and auto-configures checked serial ports and checked hosts only, even for admin group users 3.2.1. Setup new group To set up new Groups and new users, and to classify users as members of par!cular Groups: · Select Serial & Network > Users & Groups to display the configured Groups and Users. · Click Add Group to add a new Group. · Add a Group name and Descrip"on for each new Group, then nominate the Accessible Hosts, Accessible Ports and Accessible RPC Outlet(s) that you wish any users in this new Group to be able to access. Opengear User Manual. Page 71. · Click Apply. · The Administrator can Edit or Delete any added group. 3.2.2. Setup new users To set up new users, and to classify users as members of par!cular Groups: · Select Serial & Network > Users & Groups to display the configured Groups and Users. · Click Add User to add a new user. · Add a Username for each new user. You may also include informa!on related to the user (e.g. contact details) in the Descrip"on field. Note: the User Name can contain from 1 to 127 alphanumeric characters as wel as the following characters: - _ . (hyphen, underscore, and full-stop or period). · Specify which Group (or Groups) you wish the user to be a member of. · Add a confirmed Password for each new user. Note: a user's Password can contain up to 254 characters. There are no restric#ons on what characters are allowed in a password. However only the first eight characters are used to make the password hash. · SSH pass-key authen!ca!on can be used. This is more secure than password-based authen!ca!on. Paste the public keys of authorized public/private keypairs for this user in the Authorized SSH Keys field · Check Disable Password Authen"ca"on if you wish to only allow public key authen!ca!on for this user when using SSH. Opengear User Manual. Page 72. · Check Enable Dial-Back in the Dial-in Op"ons menu to allow an out-going dial-back connec!on to be triggered by logging into this port. · Enter the Dial-Back Phone Number with the phone number to call-back when the user logs in. · Check specific Accessible Hosts and Accessible Ports to nominate the serial ports and network connected hosts you wish the user to have access privileges to. · If there are configured RPCs you can check Accessible RPC Outlets to specify which outlets the user is able to control (that is, power on and off). · Click Apply. The new user will now be able to access the Network Devices, Ports and RPC Outlets you nominated as accessible plus, if the user is a Group member they can also access any other device/port/outlet that was set up as accessible to the Group Note: there are no specific limits on user number; nor on the number of users per serial port or host. So mul#ple users (Users and Administrators) can control or monitor a port or host. Similarly there are no specific limits on the group number and users can be a member of a number of Groups (and gain the cumula#ve access privileges of each Group). A user does not have to be a member of any Groups (but if the User is not even a member of the default user group then cannot use the Management Console to manage ports). Note: while there are no specific limits, the #me to re-configure does increase as the number and complexity increases. The aggregate number of users and groups should be kept under 250. The Administrator can also edit the access se$ngs for any exis!ng users: Opengear User Manual. Page 73. · Select Serial & Network > Users & Groups and click Edit to modify User access privileges. · Alterna!vely click Delete to remove the user or Disable to temporarily block access. Note: for more on enabling the SDT Connector so each user has secure tunneled remote RPD/ VNC/Telnet/HHTP/HTTPS/SoL access to the network connected hosts see chapter 5. 3.3. Authen"ca"on See chapter 8.1 for authen!ca!on configura!on details. 3.4. Network hosts To monitor and remotely access a locally networked computer or device (referred to as a Host) iden!fy the Host and specify the TCP or UDP ports/services used to control that Host. · Select Serial & Network > Network Hosts. All network-connected Hosts that have been enabled for access present as well as the related access TCP ports/services. Opengear User Manual. Page 74. · Click Add Host to enable access to a new Host (or select Edit to update the se$ngs for exis!ng Host). · Enter the IP Address or the DNS Name and Host Name (up to 254 alphanumeric characters) for the new network connected Host. · enter a Descrip"on (this is an op!onal step). · Add or edit the Permi$ed Services (or TCP/UDP port numbers) that are authorized to be used in controlling this host. Only these permi%ed services will be forwarded through by SDT to the Host. All other services (TCP/UDP ports) will be blocked. · Set the Logging Level. This specifies the level of informa!on to be logged and monitored for each Host access. See chapter 6 for more. · If the Host is a PDU or UPS power device or a server with IPMI power control, specify RPC (for IPMI and PDU) or UPS and the Device Type. The Administrator can configure these devices and enable which users have permissions to remotely cycle power etc. (see chapter 7). Otherwise leave the Device Type set to None. · If the console server has been configured with distributed Nagios monitoring enabled then you will also be presented with Nagios Se$ngs op!ons to enable nominated services on the Host to be monitored. See Chapter 9 for more. · Click Apply. This will create the new Host and also create a new Managed Device (with the same name). 3.5. Trusted networks The Trusted Networks facility allows you an nominate specific IP addresses that users (Administrators and Users) must be located at, to have access to console server serial ports: · Select Serial & Network > Trusted Networks. Opengear User Manual. Page 75. · Click Add Rule to add a new trusted network. Note: In the absence of Rules, there are no access limita#ons as to the IP address at which Users or Administrators can be located. · Select the Accessible Port(s) that the new rule is to be applied to. · Enter the Network Address of the subnet to be permi%ed access. · Specify the range of addresses that are to be permi%ed by entering a Network Mask for that permi%ed IP range. · For example, to permit all users located in the 204.15.5.0 Class C network to connect to the nominated port, would add the following Trusted Network rule: Network IP address: Subnet Mask 204.15.5.0 255.255.255.0 · To permit only the user located at a specific IP address (in this case 204.15.5.13) to connect: Network IP address: Subnet Mask 204.15.5.13 255.255.255.255 · To allow all users opera!ng from within a specific range of IP addresses (in this case the 30 addresses from 204.15.5.129 to 204.15.5.158) to be permi%ed connec!on to the nominated port: Network IP address: Subnet Mask 204.15.5.128 255.255.255.224 · Click Apply. Note: The above Trusted Networks will limit access by Users and Administrators to the console serial ports. However they do not restrict access by the Administrator to the console server itself or to a"ached hosts. To change the default se&ngs for this access, you will to need to edit the IPtables rules as described in chapter 14. 3.6. Serial port cascading Cascaded Ports enables you to cluster distributed console servers so up to 1000 serial ports Opengear User Manual. Page 76. can be configured and accessed through one IP address and managed through the one Management Console. One console server, the Master, controls other console servers as Slave units and all the serial ports on the Slave units appear as if they are part of the Master. Opengear's clustering connects each Slave to the Master with an SSH connec!on. This is done using public key authen!ca!on so the Master can access each Slave using the SSH key pair (rather than using passwords). This ensures secure authen!cated communica!ons between Master and Slaves enabling the Slave console server units to be distributed locally on a LAN or remotely around the world. 3.6.1. Automa"cally generate & upload SSH keys To set up public key authen!ca!on first generate an RSA or DSA key pair and upload them into the master and slave console servers. This can be done automa!cally from the Master. · Select System > Administra"on on the master's Management Console. · Check Generate SSH keys automa!cally. · click Apply. Next select whether to generate keys using RSA and/or DSA (if unsure, select only RSA). Genera!ng each set of keys will require approximately two minutes and the new keys will destroy any old keys of that type that may previously been uploaded. Also while the new genera!on is underway on the master func!ons relying on SSH keys (e.g. cascading) may stop func!oning un!l they are updated with the new set of keys. To generate keys: Opengear User Manual. Page 77. · Check RSA Keys, DSA Keys, or both. · Click Apply. · Once the new keys have been generated, Click here to return and the keys will automa!cally be uploaded to the master and connected slaves. 3.6.2. Manually generate & upload SSH keys To manually upload the key public and private key pair to the Master console server: · Select System > Administra"on on the master's Management Console. · Browse to the loca!on you have stored RSA (or DSA) Public Key and upload it to SSH RSA (DSA) Public Key. · Browse to the stored RSA (or DSA) Private Key and upload it to SSH RSA (DSA) Private Key. · Click Apply. Next, you must register the Public Key as an Authorized Key on the slave. In the simple case with only one master with mul!ple slaves, you need only upload the one RSA or DSA public key for each slave. Note: The use of key pairs can be confusing as in many cases one file (Public Key) fulfills two roles Public Key and Authorized Key. For a more detailed explana#on see the Authorized Keys sec#on of chapter 14.6. Also refer to this chapter if you need to use more than one set of Authorized Keys in the slave. · Select System > Administra"on on the slave's Management Console. · Browse again to the stored RSA (or DSA) Public Key and upload it to Slave's SSH Opengear User Manual. Page 78. Authorized Key. · Click Apply. The next step is to Fingerprint each new slave-master connec!on. This once-off step will validate that you are establishing an SSH session to who you think you are. On the first connec!on the Slave will receive a fingerprint from the Master which will be used on all future connec!ons. · Log in to the master console server as root. · Establish an SSH connec!on to the remote slave host: # ssh remote-host-name Once the SSH connec!on has been established you will be asked to accept the key. Answer yes and the fingerprint will be added to the list of known hosts. For more detail on Fingerprin!ng see chapter 14.6. Note: If you are asked to supply a password, then there has been a problem with uploading keys. The keys should remove any need to supply a password. 3.6.3. Configure the slaves and their serial ports You can now begin se$ng up the slaves and configuring slave serial ports from the master console server. · Select Serial & Network > Cascaded Ports on the master's Management Console. · Click Add Slave to add clustering support. Note: you cannot add any slaves un#l you have automa#cally or manually generated SSH keys. To define and configure a slave: · Enter the remote IP Address (or DNS Name) for the Slave console server. · Enter a brief Descrip"on and a short Label for the slave Use a conven!on here that enables effec!ve management of large networks of clustered console servers and the connected devices. · Enter the full number of serial ports on the slave unit in Number of Ports. Opengear User Manual. Page 79. · Click Apply. This will establish the SSH tunnel between the master and the new slave. The Serial & Network > Cascaded Ports menu displays all the slaves and the port numbers that have been allocated on the master. If the master console server has 16 ports of its own then ports 116 are pre-allocated to the master, so the first slave added will be assigned port number 17 onwards. Once you have added all the slave console servers, the slave serial ports and the connected devices are configurable and accessible from the master's Management Console menu and accessible through the Master's IP address. · Select the appropriate Serial & Network > Serial Port and Edit to configure the serial ports on the slave. · Select the appropriate Serial & Network > Users & Groups to add new users with access privileges to the slave serial ports (or to extend exis!ng users access privileges). · Select the appropriate Serial & Network > Trusted Networks to specify network addresses that can access nominated slave serial ports. · Select the appropriate Alerts & Logging > Alerts to configure slave port Connec"on, State Change or Pa$ern Match alerts. · click Apply. The configura!on changes made on the master are propagated out to all the Slaves. 3.6.4. Managing the slaves The master is in control of the slave serial ports. So for example if change a User access privileges or edit any serial port se$ng on the master, the updated configura!on files will be sent out to each slave in parallel. Each slave will then automa!cally make changes to their local configura!ons (and only make those changes that relate to its par!cular serial ports). You can s!ll use the local slave Management Console to change the se$ngs on any slave serial port (such as alter the baud rates). However these changes will be overwri%en next !me the master sends out a configura!on file update. Opengear User Manual. Page 80. Also while the master is in control of all slave serial port related func!ons, it is not master over the slave network host connec!ons or over the slave console server system itself. So slave func!ons such as IP, SMTP & SNMP Se$ngs, Date &Time, DHCP server must be managed by accessing each slave directly and these func!ons are not over wri%en when configura!on changes are propagated from the master. Similarly the slaves Network Host and IPMI se$ngs have to be configured at each slave. Also the master's Management Console provides a consolidated view of the se$ngs for its own and the en!re slave's serial ports, however the master does not provide a fully consolidated view. For example if you want to find out who's logged in to cascaded serial ports from the master, you'll see that Status > Ac"ve Users only displays those users ac!ve on the master's ports, so you may need to write custom scripts to provide this view. This is covered in chapter 10. 3.7. Serial port redirec"on (PortShare) Opengear's PortShare so&ware delivers the virtual serial port technology your Windows and Linux applica!ons need to open remote serial ports and read the data from serial devices that are connected to your console server. PortShare is supplied free with each console server and you are licensed to install PortShare on one or more computers for accessing any serial device connected to a console server port. PortShare for Windows The portshare_setup.exe program is included on the CD supplied with your console server. A copy can be freely downloaded from the &p site. Refer to the PortShare User Manual and Quick Start for details on installa!on and opera!on. PortShare for Linux The PortShare driver for Linux maps the console server serial port to a host tty port. Opengear has released the portshare-serial-client as an open source u!lity for Linux, AIX, HPUX, SCO, Solaris and UnixWare. This u!lity can be freely downloaded from the &p site. The PortShare serial port redirector allows you to use a serial device connected to the remote console server as if it were connected to your local serial port. The portshare-serialclient creates a pseudo %y port, connects the serial applica!on to the pseudo %y port, receives data from the pseudo %y port, transmits it to the console server through network and receives data from the console server through network and transmits it to the pseudo-%y port. The .tar file can be freely downloaded from the &p site. Refer to the PortShare User Manual and Quick Start for details on installa!on and opera!on. 3.8. Managed devices Managed Devices presents a consolidated view of all the connec!ons to a device that can be accessed and monitored through the console server. To view the connec!ons to the devices: · Select Serial & Network > Managed Devices. This screen displays all the Managed Device with their Descrip!on, Notes and lists of all the configured Connec!ons: Serial Port # if serially connected. Opengear User Manual. Page 81. USB IP Address Power PDU/outlet UPS connec"ons if USB connected. if network connected. if applicable. if applicable. Devices such as servers will commonly have more than one power connec!ons (e.g. dual power supplied) and more than one network connec!on (for example, for BMC/service processor). All users can view (but not edit) these Managed Device connec!ons by selec!ng Manage > Devices. Whereas the Administrator can edit, add to and delete these Managed Devices and their connec!ons. To edit an exis!ng device and add a new connec!on: · Select Serial & Network > Managed Devices. · Click Edit. · Click Add Connec"on. · Select the connec!on type for the new connec!on (Serial, Network Host, UPS or RPC). · Select the specific connec!on from the presented list of configured unallocated hosts/ ports/outlets. Opengear User Manual. Page 82. To add a new network connected Managed Device: · The Administrator adds a new network connected Managed Device using Add Host on the Serial & Network > Network Host menu. This automa!cally creates a corresponding new Managed Device (as covered in chapter 3.4). · When adding a new network connected RPC or UPS power device, you set up a Network Host, designate it as RPC or UPS, then go to RPC Connec"ons (or UPS Connec"ons) to configure the relevant connec!on. · A corresponding new Managed Device (with the same Name and Descrip"on as the RPC/ UPS Host) is not created un!l this connec!on step is completed (see chapter 8). Note: the outlet names on a newly created PDU will, by default, be "Outlet 1" and "Outlet 2". When you connect an par#cular Managed Device (that draws power from the outlet) the outlet will take up the name of the powered Managed Device. To add a new serially connected Managed Device: · Configure the serial port using the Serial & Network > Serial Port menu (see chapter 3.1). · Select Serial & Network > Managed Devices. · Click Add Device. · Enter a Device Name and Descrip"on for the Managed Device. · Click Add Connec"on and select Serial and the Port that connects to the Managed Device. · click Add Connec"on to add a UPS/RPC power connec!on or network connec!on or another serial connec!on. · Click Apply. Note: To set up a new serially connected RPC UPS or EMD device, you configure the serial port, designate it as a Device then enter a Name and Descrip#on for that device in the Serial & Network: RPC Connec#ons (or UPS Connec#ons or Environmental). When applied, this will automa#cally create a corresponding new Managed Device with the same Name and Descrip#on as the RPC/UPS Host (see chapter 7). Note: the outlet names on the PDU will, by default, be "Outlet 1" and "Outlet 2". When you connect a par#cular Managed Device (that draws power from the outlet) the outlet will take up the name of the powered Managed Device. Opengear User Manual. Page 83. 3.9. IPsec VPN The ACM7000, ACM5500, ACM5000, CM7100, IM7200 and IM4200 family of advanced console servers include Openswan, a Linux implementa!on of the IPsec (IP Security) protocols, which can be used to configure a Virtual Private Network (VPN). The VPN allows mul!ple sites or remote administrators to access the Opengear advanced console server (and Managed Devices) securely over the Internet. The administrator can establish an encrypted authen!cated VPN connec!ons between advanced console serves distributed at remote sites and a VPN gateway (such as Cisco router running IOS IPsec) on their central office network. Users and administrators at the central office can then securely access the remote console servers and connected serial console devices and machines on the Management LAN subnet at the remote loca!on as though they were local. All these remote console servers can then be monitored with a CMS6000 on the central network. With serial bridging, serial data from controller at the central office machine can be securely connected to the serially controlled devices at the remote sites (see chapter 3.1.) The road warrior administrator can use a VPN IPsec so&ware client such as TheGreenBow (h%ps://thegreenbow.com/) or Shrew So& (h%ps://shrew.net/) to remotely access the advanced console server and every machine on the Management LAN subnet at the remote loca!on. Configura!on of IPsec is quite complex so Opengear provides a simple GUI interface for basic set up as described below. However for more detailed informa!on on configuring Openswan IPsec at the command line and interconnec!ng with other IPsec VPN gateways and road warrior IPsec so&ware see h%p://wiki.openswan.org and h%p://opengear.com/faq.html. 3.9.1. Enable the VPN gateway · Select Serial & Networks > IPsec VPN. · Click Add. · complete the Add IPsec Tunnel screen. Opengear User Manual. Page 84. · Enter a descrip!ve name to iden!fy the added IPsec Tunnel. For example West-St-Outlet. · Select the Authen!ca!on Method: either RSA digital signatures or a Shared secret (PSK). If you select RSA you will asked to click here to generate keys. This will generate an RSA public key for the console server (the Le& Public Key). You will need to find out the key to be used on the remote gateway, then cut and paste it into the Right Public Key. If you select Shared secret you will need to enter a Pre-shared secret (PSK). The PSK must match the PSK configured at the other end of the tunnel. · In Authen"ca"on Protocol select the authen!ca!on protocol to be used. Either authen!cate as part of ESP (Encapsula"ng Security Payload) encryp!on or separately using the AH (Authen"ca"on Header) protocol. · Enter a Le& ID and Right ID. This is the iden!fier that the Local host/gateway and remote host/gateway use for IPsec nego!a!on and authen!ca!on. Each ID must include an @ and can include a fully qualified domain name preceded by @ (for example, le&@example.com). · Enter the public IP or DNS address of this Opengear VPN gateway as the Le& Address. You can leave this blank to use the interface of the default route. · In Right Address, if the remote end has a sta!c or dyndns address, enter the public IP or DNS address of the remote end of the tunnel. Otherwise leave this blank. · If the Opengear VPN gateway is serving as a VPN gateway to a local subnet (for example, the console server has a Management LAN configured) enter the private subnet details in Le& Subnet. Opengear User Manual. Page 85. Use the CIDR nota!on, where the IP address number is followed by a slash and the number of `one' bits in the binary nota!on of the netmask. For example 192.168.0.0/24 indicates an IP address where the first 24 bits are used as the network address. This is the same as 255.255.255.0. If the VPN access is only to the console server itself and to its a%ached serial console devices then leave Le& Subnet blank. · If there is a VPN gateway at the remote end, enter the private subnet details in Right Subnet. Again use CIDR nota!on and leave blank if there is only a remote host. · Select Ini"ate Tunnel if the tunnel connec!on is to be ini!ated from the Le& console server end. This can only be ini!ated from the VPN gateway (Le&) if the remote end was configured with a sta!c (or dyndns) IP address. · Click Apply to save changes. Note: It is essen#al the configura#on details set up on the advanced console server (referred to as the Le( or Local host) exactly matches the set up entered when configuring the Remote Opengear User Manual. Page 86. (Right) host/gateway or so(ware client. Refer to the h"p://www.opengear.com/faq.html for details on configuring these remote ends. 3.10. OpenVPN The ACM7000, ACM5500, ACM5000, CM7100, IM7200 and IM4200 family of advanced console servers with Firmware v3.2 and later, include OpenVPN. OpenVPN uses the OpenSSL library for encryp!on, authen!ca!on, and cer!fica!on, which means it uses SSL/TSL (Secure Socket Layer/Transport Layer Security) for key exchange and can encrypt both data and control channels. Using OpenVPN allows for the building of cross-pla*orm, point-to-point VPNs using either X.509 PKI (Public Key Infrastructure) or custom configura!on files. OpenVPN allows secure tunneling of data through a single TCP/UDP port over an unsecured network, thus providing secure access to mul!ple sites and secure remote administra!on to a console server over the Internet. OpenVPN also allows the use of Dynamic IP addresses by both the server and client thus providing client mobility. For example, an OpenVPN tunnel may be established between a roaming windows client and an Opengear advanced console server within a data center. Configura!on of OpenVPN can be complex so Opengear provides a simple GUI interface for basic set up as described below. However for more detailed informa!on on configuring OpenVPN Access server or client refer to the HOW TO and FAQs at h%ps://openvpn.net/. 3.10.1. Enable the OpenVPN · Select Serial & Netwoks > OpenVPN. · Click Add. · Fill-out the required fields on the Add OpenVPN Tunnel screen. · Enter a descrip!ve name to iden!fy the added IPsec Tunnel. For example West-St-Outlet. Opengear User Manual. Page 87. · Select the authen!ca!on method to be used. To authen!cate using cer!ficates select PKI (X.509 Cer"ficates). To authen!cate using a custom configura!on select Custom Configura"on to upload custom configura!on files. Note: Custom configura#ons must be stored in /etc/config. If you select PKI (public key infrastructure) you will need to establish: · a separate cer!ficate (also known as a public key). This Cer!ficate File will be a *.crt file type. · a Private Key for the server and each client. This Private Key File will be a *.key file type. · A master Cer!ficate Authority (CA) cer!ficate and key which is used to sign each of the server and client cer!ficates. This Root CA Cer!ficate will be a *.crt file type. For a server you may also need dh1024.pem (Diffie Hellman parameters). See h%p://openvpn.net/easyrsa.html for a guide to basic RSA key management. For alterna!ve authen!ca!on methods see h%p://openvpn.net/index.php/documenta!on/ howto.html#auth. For more informa!on also see h%p://openvpn.net/howto.html. · Select the Device Driver to be used, either Tun-IP or Tap-Ethernet. The TUN (network tunnel) and TAP (network tap) drivers are virtual network drivers that support IP tunneling and Ethernet tunneling, respec!vely. TUN and TAP are part of the Linux kernel. Opengear User Manual. Page 88. · Select either UDP or TCP as the Protocol. UDP is the default and preferred protocol for OpenVPN. · In Tunnel Mode, nominate whether this is the Client or Server end of the tunnel. When running as a server, the advanced console server supports mul!ple clients connec!ng to the VPN server over the same port. · Check or uncheck the Compression bu%on to enable or disable compression. 3.10.2. Configure as server or client · Complete the Client Details or Server Details depending on the Tunnel Mode selected. If Client has been selected, the Primary Server Address will be the address of the OpenVPN Server. If Server has been selected, enter the IP Pool Network address and the IP Pool Network mask for the IP Pool. The network defined by the IP Pool Network address/mask is used to provide the addresses for connec!ng clients. · Click Apply. · To enter authen!ca!on cer!ficates and files, Edit the OpenVPN tunnel. Opengear User Manual. Page 89. · Select the Manage OpenVPN Files tab. Upload or browse to relevant authen!ca!on cer!ficates and files. · Click Apply. Saved files will be displayed in red on the right-hand side of the Upload bu%on. · To enable OpenVPN, Edit the OpenVPN tunnel. · Check the Enabled bu%on. · Click Apply. Note: the console server system #me must be correct. Otherwise authen#ca#on issues can arise. · Select Status > Sta"s"cs to verify that the tunnel is opera!onal. 3.10.3. Windows OpenVPN client & server setup Windows does not come standard with any OpenVPN server or client. This sec!on outlines the installa!on and configura!on of a Windows OpenVPN client or a Windows OpenVPN server and se$ng up a VPN connec!on to a console server. Console servers with firmware V3.5.2 and later will generate Windows client config Opengear User Manual. Page 90. automa!cally from the GUI for Pre-shared Secret (Sta!c Key File) configura!ons. Alternately OpenVPN GUI for Windows so&ware (which includes the standard OpenVPN package plus a Windows GUI) can be downloaded from h%ps://openvpn.net/. Once installed on the Windows machine, an OpenVPN icon will present in the No!fica!on Area located in the right side of the taskbar. · Right click on this icon to start (and stop) VPN connec!ons, and to edit configura!ons and view logs. When the OpenVPN so&ware is started, the C:\Program Files\OpenVPN\config folder will be scanned for .opvn files. This folder is rechecked for new configura!on files whenever the OpenVPN GUI icon is right-clicked. So once the OpenVPN client is installed, a configura!on file will need to be created. · Using a text editor, create an xxxx.ovpn file and save in C:\Program Files\OpenVPN \config\. For example, C:\Program Files\OpenVPN\config\client.ovpn. · An example OpenVPN Windows client configura!on file: # description: IM4216_client client proto udp verb 3 dev tun remote 192.168.250.152 port 1194 ca c:\\openvpnkeys\\ca.crt cert c:\\openvpnkeys\\client.crt key c:\\openvpnkeys\\client.key nobind persist-key persist-tun comp-lzo · An example OpenVPN Windows server configura!on file: server 10.100.10.0 255.255.255.0 port 1194 Opengear User Manual. Page 91. keepalive 10 120 proto udp mssfix 1400 persist-key persist-tun dev tun ca c:\\openvpnkeys\\ca.crt cert c:\\openvpnkeys\\server.crt key c:\\openvpnkeys\\server.key dh c:\\openvpnkeys\\dh.pem comp-lzo verb 1 syslog IM4216_OpenVPN_Server The Windows client/server configura!on file op!ons are: op"ons # comments and notes client or server proto [udp | tcp] descrip"on Lines beginning with # are ignored by OpenVPN. Specify whether this will be a client or server configura!on file. In the server configura!on file, define the IP address pool and netmask. For example server 10.100.10.0 255.255.255.0 Set the protocol. mssfix size Client and server must be the same. Set a packet's maximum size. verb level Only useful for UDP if problems occur. Set log-file verbosity. Values range from 015. dev [tun | tap] 0 = silent except for fatal errors. 3 = medium output logging. Good for general use. 5 = helps with debugging connec!on problems. 9 = extremely verbose. Excellent for troubleshoo!ng. Set dev tun to create a routed IP tunnel. Set dev tup to create an Ethernet tunnel. remote host Client and server must be the same. Set the hostname or IP address of the OpenVPN server. Port Keepalive ping-value down-value Mandatory but a client-only se$ng. The UDP or TCP port of the OpenVPN server. Uses ping to keep the OpenVPN session alive. For example: Keepalive 10 120 pings the server every ten seconds and assumes the remote peer is down if no ping is received a&er 120 seconds (two minutes). h%p-proxy proxy-server proxy-port-# If a proxy is required to access a server, enter the proxy-server's hostname or IP address and its port #. Opengear User Manual. Page 92. ca file-name Enter the CA cer!ficate file name and loca!on The same CA cer!ficate can be used by the server and all clients. Ensure each \ in the directory path is escaped. cert file-name For example c:\openvpnkeys\ca.crt must be entered as c:\\openvpnkeys\\ca.crt Enter the client's or server's cer!ficate file name and loca!on Each client should have its own cer!ficate and key files. key file-name As above, each \ in the directory path must be escaped. Enter the client's or server's key file name and loca!on Each client should have its own cer!ficate and key files. dh file-name As above, each \ in the directory path must be escaped. Enter the path to thekey with the Diffie-Hellman parameters. Nobind A server-only se$ng. Used when clients do not need to bind to a local address or specific local port number. persist-key persist-tun cipher [BF-CBC Blowfish | AES-128CBC AES | DES-EDE3-CBC Triple DES] This is the case in most client configura!ons. Prevents the reloading of keys across restarts. Prevents the closing and reopening of TUN/TAP devices across restarts. Sets the cryptographic cipher. BF-CBC Blowfish is the default if no cipher is explicitly set. comp-lzo The client and server must use the same se$ngs. Enables compression on the OpenVPN link. syslog If enabledit must be set on the client and the server. Located in syslog on Linux or Unix. Located in \Program Files\OpenVPN\log\ if running as a service on Windows. To ini!ate the OpenVPN tunnel following the crea!on of the client/server configura!on files: · Right click on the OpenVPN icon in the No!fica!on Area. · Select the newly created client or server configura!on. · Click Connect in the presented sub-menu. · The log file will display as the connec!on is established. · Once established, the OpenVPN icon will display a message no!fying of the successful Opengear User Manual. Page 93. connec!on and assigned IP. This informa!on, as well as the !me the connec!on was established, is available any!me by scrolling over the OpenVPN icon. Note: An alternate, open-source OpenVPN Windows client can be downloaded from h"ps:// openvpn.net/index.php/open-source/downloads.html. See h"ps://openvpn.net/index.php/ access-server/docs for help. 3.11. PPTP VPN The ACM7000, ACM5500, ACM5000, CM7100, IM7200 and IM4200 family of advanced console servers with Firmware V3.5.2 and later, include a PPTP (Point-to-Point Tunneling Protocol) server. PPTP is typically used for communica!ons over a physical or virtual serial link. The PPP endpoints define a virtual IP address to themselves. Routes to networks can Opengear User Manual. Page 94. then be defined with these IP addresses as the gateway, which results in traffic being sent across the tunnel. PPTP establishes a tunnel between the physical PPP endpoints and securely transports data across the tunnel. The strength of PPTP is its ease of configura!on and integra!on into exis!ng Microso& infrastructure. It is generally used for connec!ng single remote Windows clients. If you take your portable computer on a business trip, you can dial a local number to connect to your Internet access service provider (ISP) and then create a second connec!on (tunnel) into your office network across the Internet and have the same access to your corporate network as if you were connected directly from your office. Similarly, telecommuters can also set up a VPN tunnel over their cable modem or DSL links to their local ISP. To set up a PPTP connec!on from a remote Windows client to your Opengear appliance and local network: · Enable and configure the PPTP VPN server on your Opengear appliance. · Set up VPN user accounts on the Opengear appliance and enable the appropriate authen!ca!on. · Configure the VPN clients at the remote sites. The client does not require special so&ware as the PPTP Server supports the standard PPTP client so&ware included with Windows NT and later. · Connect to the remote VPN. 3.11.1. Enable the PPTP VPN server · Select PPTP VPN on the Serial & Networks menu. · Click the Enable check box to enable the PPTP Server. · Select the Minimum Authen"ca"on Required. Opengear User Manual. Page 95. Access is denied to remote users a%emp!ng to connect using an authen!ca!on scheme weaker than the selected scheme. The schemes are described below, from strongest to weakest. Encrypted Authen"ca"on (MS-CHAP v2). The strongest type of authen!ca!on to use. This is the recommended op!on. Weakly Encrypted Authen"ca"on (CHAP). This is the weakest type of encrypted password authen!ca!on to use. It is not recommended that clients connect using this as it provides very li%le password protec!on. Also note that clients connec!ng using CHAP are unable to encrypt traffic. Unencrypted Authen"ca"on (PAP). This is plain text password authen!ca!on. When using this type of authen!ca!on, the client password is transmi%ed unencrypted. None. No encryp!on at all. · Select the Required Encryp"on Level. Access is denied to remote users a%emp!ng to connect not using this encryp!on level. 40 bit or 128 bit encryp"on is recommended. · In Local Address enter the IP address to assign to the server's end of the VPN connec!on. · In Remote Addresses enter the pool of IP addresses to assign to the incoming client's VPN connec!ons (e.g. 192.168.1.10-20). These must be free IP addresses, from the network (typically the LAN) that remote users are assigned while connected to the Opengear appliance. · Enter the desired value of the Maximum Transmission Unit (MTU) for the PPTP interfaces into the MTU field (defaults to 1400). · In the DNS Server field, enter the IP address of the DNS server that assigns IP addresses to connec!ng PPTP clients. · In the WINS Server field, enter the IP address of the WINS server that assigns IP addresses to connec!ng PPTP client. · Enable Verbose Logging to assist in debugging connec!on problems. · Click Apply. 3.11.2. Add a PPTP user · Navigate to Serial & Networks > Users & Groups. · Complete the fields as covered in chapter 3.2. · Ensure the pptpd Group has been checked, to allow access to the PPTP VPN server. Note: users in this group will have their password stored in clear text. · Keep note of the username and password for when you need to connect to the VPN connec!on. · Click Apply. Opengear User Manual. Page 96. 3.11.3. Setup a remote PPTP client Ensure the remote VPN client PC has Internet connec!vity. To create a VPN connec!on across the Internet, you must set up two networking connec!ons. One connec!on is for the ISP, and the other connec!on is for the VPN tunnel to the Opengear appliance. Note: This procedure sets up a PPTP client under Windows 7 Professional. The steps may vary slightly depending on your network access or if you are using a different version of Windows. · Login to your Windows system with administrator privileges. · From the Network & Sharing Center in the Control Panel select Network Connec"ons and create a new connec!on. Opengear User Manual. Page 97. · Select Use My Internet Connec"on (VPN) and enter the IP Address of the Opengear appliance. Note: To connect remote VPN clients to the local network, you need to know the user name and password for the PPTP account you added, as well as the Internet IP address of the Opengear appliance. If your ISP has not allocated you a sta#c IP address, consider using a dynamic DNS service. Otherwise you must modify the PPTP client configura#on each #me your Internet IP address changes. 3.12. Call home All console servers with Firmware V3.2 and later, include the Call Home feature which ini!ates the setup of a secure SSH tunnel from the console server to a centralized Lighthouse VM, Lighthouse Standard, Lighthouse Enterprise, CMS6100 or VCMS server (referred to herein as CMS). The console server then registers as a "candidate" on the CMS. Once accepted there it becomes a Managed Console Server. The CMS will then monitor the Managed Console Server, and administrators can access the remote Managed Console Server, through the CMS. This access is available even when the remote console server is behind a third party firewall or has a private non-routable IP addresses (which is o&en the case when the console server is connected via a cellular modem connec!on). CMS maintains public key authen!cated SSH connec!ons to each of its Managed Console Servers. These connec!ons are used for monitoring, commanding and accessing the Managed Console Servers and the Managed Devices connected to the Managed Console Server. To manage Local Console Servers, or console servers that are reachable from the CMS, the SSH connec!ons are ini!ated by CMS. To manage Remote Console Servers, or console servers that are firewalled, not routable, or otherwise unreachable from the CMS, the SSH connec!ons are ini!ated by the Managed Console Server via an ini!al Call Home connec!on. This ensures secure, authen!cated communica!ons and enables Managed Console Servers units to be distributed locally on a LAN, or remotely around the world. 3.12.1. Setup call home candidate To set up the console server as a Call Home management candidate on the CMS: · Select Call Home on the Serial & Network menu. · If you have not already generated or uploaded an SSH key pair for this console server, you will need to do so before proceeding (see chapter 2). Opengear User Manual. Page 98. · Click Add. · Enter the IP address or DNS name (for example, the dynamic DNS address) of the CMS. · Enter the Password that you configured on the CMS as the Call Home Password. · Click Apply. These steps ini!ate the Call Home connec!on from the console server to the CMS. This creates an SSH listening port on the CMS, and sets the console server up as a candidate. Once the candidate has been accepted on the CMS (as outlined in the next sec!on) an SSH tunnel to the console server is then redirected back across the Call Home connec!on. The console server has now become a Managed Console Server and the CMS can connect to and monitor it through this tunnel. 3.12.2. Accept call home candidate as managed console This sec!on gives an overview on configuring the CMS to monitor console servers that are connected via Call Home. For more details refer to the Lighthouse CMS User Manual. You first must enter a new Call Home Password on the CMS. This password is used solely for accep!ng Call Home connec!ons from candidate console servers. So the CMS can be contacted by the console server it must have either a sta!c IP address or -- if using DHCP -- be configured to use a dynamic DNS service. The Configure > Managed Console Servers screen on the CMS shows the status of local and remote Managed Console Servers and candidates. The Managed Console Server sec!on shows the console servers currently being monitored by the CMS. Opengear User Manual. Page 99. The Detected Console Servers sec!on shows the Local Console Servers drop down list (which lists all the console servers which are on the same subnet as the CMS but which not currently being monitored) and the Remote Console Servers drop down list (which lists all the console servers that have established a Call Home connec!on but which are not currently being monitored). Put another way, the Remote Console Servers drop down list lists CMS candidates. To update either list, click Refresh. To add a console server candidate to the Managed Console Server list: · Select it from the Remote Console Servers drop down list. · click Add. · Enter the IP Address and SSH Port (if these fields have not been auto-completed). · Enter a Descrip"on and unique Name for the Managed Console Server you are adding. · Enter the Remote Root Password (that is, the System Password that has been set on this Managed Console Server). This password is used by the CMS to propagate auto generated SSH keys and then forgo%en. It will not be stored. · Click Apply. The CMS will now set up secure SSH connec!ons to and from the Managed Console Server and will retrieve its Managed Devices, user account details and configured alerts. 3.12.3. Calling home to a generic central SSH server If you are connec!ng to a generic SSH server (not a Lighthouse CMS) you may configure Advanced se$ngs. · Enter the SSH Server Port and SSH User to authen!cate as. · Enter the details for the SSH port forward(s) to create. Opengear User Manual. Page 100. By selec!ng Listening Server, you may create a Remote port forward from the Server to this unit, or a Local port forward from this unit to the Server. · Specify a Listening Port to forward from. Leave this field blank to allocate an unused port · Enter the Target Server and Target Port that will be the recipient of forwarded connec!ons. · Click Add. 3.13. IP passthrough IP Passthrough is used to make a modem connec!on (for example, the Opengear's internal cellular modem) appear like a regular Ethernet connec!on to a third-party downstream router, allowing the downstream router to use the Opengear's modem connec!on as a primary or backup WAN interface. The Opengear provides the modem IP address and DNS details to the downstream device over DHCP and transparently passes network traffic to and from the modem and router. While IP Passthrough essen!ally turns an Opengear into a modem-to-Ethernet half bridge, some specific layer 4 services (HTTP/HTTPS/SSH) may s!ll be terminated at the Opengear (Service Intercepts). Also, services running on the Opengear can ini!ate outbound cellular connec!ons independent of the downstream router. This allows the Opengear to con!nue to be used for out-of-band management and aler!ng and also be managed via Lighthouse, while in IP Passthrough mode. 3.13.1. Downstream router setup To use failover connec!vity on the downstream router (aka Failover to Cellular or F2C), it must have two or more WAN interfaces. Note: Failover in IP Passthrough context is performed en#rely by the downstream router, and the built-in out-of-band failover logic on the Opengear itself is not available while in IP Passthrough mode. · Connect an Ethernet WAN interface on the downstream router to the Opengear's Network Interface or Management LAN port with an Ethernet cable. · Configure this interface on the downstream router to receive its network se$ngs via DHCP. · If failover is required, configure the downstream router for failover between its primary interface and the Ethernet port connected to the Opengear. 3.13.2. IP passthrough pre-requisite pre-configura"on steps. Configure the Network Interface and, where applicable, Management LAN interfaces with sta!c network se$ngs. · Click Serial & Network > IP. · For Network Interface and, where applicable, Management LAN, select Sta"c for the Opengear User Manual. Page 101. Configura"on Method and enter the network se$ngs (see the chapter 2.3 for detailed instruc!ons). · For the interface connected to the downstream router, you may choose any dedicated private network. This network will only exist between the Opengear and downstream router and will not normally be accessible. · For the other interface, configure it as you would per normal on the local network. · For both interfaces, leave Gateway blank. Configure the Opengear modem in Always On Out-of-band mode. · For a cellular connec!on, click System > Dial > Internal Cellular Modem. · Select Enable Dial-Out and enter carrier details such as APN (see chapter 4.6 for detailed instruc!ons). 3.13.3. IP passthrough cer"fica"on To configure IP Passthrough: · Click Serial & Network > IP Passthrough. · check Enable. · Select the Opengear Modem to use for upstream connec!vity. · Op!onally, enter the MAC Address of the downstream router's connected interface. Note: if an MAC address is not specified, the Opengear will passthrough to the first downstream device reques#ng a DHCP address. · Select the Opengear Ethernet Interface to use for connec!vity to the downstream router · Click Apply. 3.13.4. Service intercepts These allow the Opengear to con!nue to provide services for e.g. out-of-band management when in IP Passthrough mode. Connec!ons to the modem address on the specified intercept port(s) will be handled by the Opengear, rather than being passed through to the downstream router. Opengear User Manual. Page 102. · For the required service of HTTP, HTTPS or SSH, check Enable. · Op!onally, modify the Intercept Port to an alternate port (for example, 8443 for HTTPS). This is useful if you want to con!nue to allow the downstream router to remain accessible via its regular port. 3.13.5. IP passthrough status · Refresh the page to view the Status sec!on. It displays the modem's External IP Address being passed through, the Internal MAC Address of the downstream router (only populated when the downstream router accepts the DHCP lease), and the overall running status of the IP Passthrough service. Addi!onally, you may be alerted to the failover status of the downstream router by configuring a Routed Data Usage Check under Alerts & Logging > Auto-Response. 3.13.6. Caveats Some downstream routers may be incompa!ble with the gateway route. This may happen when IP Passthrough is bridging a 3G cellular network where the gateway address is a pointto-point des!na!on address and no subnet informa!on is available. The console server sends a DHCP netmask of 255.255.255.255. Devices will normally correctly construe this as a `single host route' on the interface, but as this is an unusual se$ng for Ethernet, some older downstream devices may have issues. Intercepts for local services will not work if the Opengear is using a default route other than the modem. As per normal opera!on, they will also not work unless the service is enabled and access to the service is enabled (see System > Services > Service Access > Dialout/Cellular). Outbound connec!ons origina!ng from consoler servers to remote services are supported (for example, sending SMTP email alerts, SNMP traps, ge$ng NTP !me, and IPSec tunnels). There is, however, a miniscule risk of connec!on failure should both the console server and the downstream device try to access the same UDP or TCP port on the same remote host at the same !me where they have randomly chosen the same origina!ng local port number. Opengear User Manual. Page 103. 4.Firewall, failover, & OOB access The console server has a number of out-of-band access capabili!es and transparent fail-over features, to ensure high availability. So if there's difficulty in accessing the console server through the main network path, all console server models provide out-of-band (OOB) access and the Administrator can s!ll access it (and its Managed Devices) from a remote loca!on. All console server models support serially a%aching an external dial-up modem and configuring dial-in OOB access. Some models with USB ports support a%aching an external USB modem. Some models also come standard with an internal modem. These modems can also be configured for dial-in OOB access. All console server models with an internal or externally a%ached modem (and V3.4 firmware or later) can be configured for out-dial to be permanently connected . The advanced console server models can also be configured for transparent out-dial failover. So in the event of a disrup!on in the principal management network, an external dial-up ppp connec!on is automa!cally established. These advanced console server models can also be accessed out-of-band using an alternate broadband link and also offer transparent broadband failover. Models with an internal cellular modem can be configured for OOB cellular access or for cellular transparent failover or can be configured as a cellular router. 4.1. Dial-up modem connec"on To enable dial-in or dial-out you must first ensure there is a modem a%ached to the console server. Opengear User Manual. Page 104. All IM4200 and IM7200 models, ACM5508-2-M and ACM5003-M come with an internal modem which can provide for OOB dial-in access. These models will display an Internal Modem Port tab under System > Dial as well as the Serial DB9 Port tab. The other CM7100, ACM7000, ACM5500 and ACM5000 models also support external USB modems. The USB modem will be auto-detected and an External USB Modem Port tab will come up under System > Dial in addi!on to the Serial DB9 Port tab. All console server models support an external modem (any brand) a%ached via a serial cable to the console/modem port for OOB dial-in access. The serial ports on the ACM7000, ACM5500 and ACM5000 are, by default, all configured as RJ serial Console Server ports. However Port 1 can be configured to be the Local Console/ Modem port. 4.2. OOB dial-in access Once a modem has been a%ached to the console server you can configure the console server for dial-in PPP access. The console server will then await an incoming connec!on from a dial-in at remote site. Next the remote client dial-in so&ware needs to be configured to establish the connec!on between the Administrator's client modem to the dial in modem on the console server. 4.2.1. Configure dial-in PPP Enable PPP access on the internal or externally a%ached modem: · Navigate to System > Dial. · In the sec!on appropriate to the port being configured (Serial DB9 Port or Internal Modem Port or External USB Port) Select the Baud Rate and Flow Control that will communicate with the modem. By default the modem port on all console servers is set with so&ware flow control and the baud rate is set at: 115200 baud for external modems connected to the local console port on CM7100, IM7200 and IM4200 console servers Opengear User Manual. Page 105. 9600 baud for the internal modem or external USB modem and for external modems connected to the Console serial ports which have been reassigned for dial-in access (on ACM5000, ACM5500 and ACM7000. When enabling OOB dial-in it is recommended that the Serial Se$ngs be changed to 38400 Baud Rate with Hardware Flow Control. Note: you can further configure the console/modem port (e.g. to include modem init strings) by edi#ng /etc/mgetty.config files as described in the chapter 13. · Check the Enable Dial-In Access check box. · In the Remote Address field, enter the IP address to be assigned to the dial-in client. You can select any address for the Remote IP Address. However it must be in the same network range as the Local IP Address (for example, 200.100.1.12 and 200.100.1.67). · In the Local Address field enter the IP address for the Dial-In PPP Server. This is the IP address that will be used by the remote client to access console server once the modem connec!on is established. Again you can select any address for the Local IP Address but it must both be in the same network range as the Remote IP Address. · The Default Route op!on sets the dialed PPP connec!on as the default console server route. · The Custom Modem Ini"aliza"on op!on allows a custom AT string modem ini!aliza!on string to be entered (e.g. AT&C1&D3&K3). · Select the Authen"ca"on Type required. Access is denied to remote users a%emp!ng to connect using an authen!ca!on scheme weaker than the selected scheme. The schemes, from strongest to weakest, are: Encrypted Authen"ca"on (MS-CHAP v2). Recommended. The strongest authen!ca!on. Weakly Encrypted Authen"ca"on (CHAP). This is the weakest encrypted password authen!ca!on to use. Not recommended as it provides very li%le password protec!on. Also note that clients connec!ng using CHAP are unable to encrypt traffic. Unencrypted Authen"ca"on (PAP). This is plain text password authen!ca!on. When using this type of authen!ca!on, the client password is transmi%ed unencrypted. None. No encryp!on at all. · Select the Required Encryp"on Level. Access is denied to remote users a%emp!ng to connect not using this encryp!on level. 40 bit or 128 bit encryp"on is recommended. Note: Firmware v3.5.2 and later support mul#ple dial-in users, setup with dialin Group membership. The User name and Password for the dial-in PPP link, and any dial-back phone numbers are configured during User set up. Earlier firmware only supports one PPP dial-in account. Chapter 14 has Linux command examples to control modem port opera!on at the shell. 4.2.2. Using SDT connector client Administrators can use their SDT Connector client to set up secure OOB dial-in access to Opengear User Manual. Page 106. remote console servers. The SDT Connector Java client so&ware provides point-and-click secure remote access. OOB access uses an alternate path for connec!ng to the console server to that used for regular data traffic. Start an OOB connec!on in SDT Connector by ini!a!ng a dial-up connec!on, or adding an alternate route to the console server. SDT Connector allows for maximum flexibility in this regard, by allowing you to provide your own scripts or commands for star!ng and stopping the OOB connec!on. See chapter 5.5 for more. 4.2.3. Setup Windows XP or later client Navigate to Start Menu > Control Panel. Click Network Connec"ons. Click the New Connec"on Wizard. Select Connect to the Internet Click Next. On the Ge$ng Ready screen select Set up my connec"on manually. Click Next. On the Internet Connec!on screen select Connect using a dial-up modem. Click Next. Enter a Connec"on Name (any name you choose) Enter the dial-up Phone number that will connect thru to the console server modem. Enter the PPP User name and Password you have set up for the console server. 4.2.4. Setup earlier Windows clients For Windows 2000, the PPP client set up procedure is the same as above, except you get to the Dial-Up Networking Folder by clicking Start and selec!ng Se!ngs. Then click through Network > Dial-up Connec"ons > Make New Connec"on. 4.2.5. Setup Linux clients The online tutorial h%p://yolinux.com/TUTORIALS/LinuxTutorialPPP.html presents a selec!on of methods for establishing a dial up PPP connec!on. · Command line PPP and manual configura!on (which works with any Linux distribu!on). · Using the Linuxconf configura!on tool (for Red Hat compa!ble distribu!ons). This configures the scripts ifup and ifdown to start and stop a PPP connec!on. · Using the Gnome control panel configura!on tool. · Using WVDIAL and the Redhat Dialup configura!on tool. · Using the GUI dial program X-isp. Opengear User Manual. Page 107. Note: for all PPP clients set up TCP/IP as the only protocol enabled; set the Server to assign IP address and do DNS; do not set console server PPP as the default Internet connec#on. 4.3. Dial-out access A console server modem, internal or external, can be set in Failover mode (dialing-out a&er a ping failure) or with always-on dial-out. In either case, if disrupted, the console server tries to re-establish connec!on. 4.3.1. Always-on dial-out With firmware v3.4 and later console server modems can be configured for always-on dial-out, with a permanent external dial-up ppp connec!on. · Navigate to System > Dial. Opengear User Manual. Page 108. · check the Enable Dial-Out to allow outgoing modem communica!ons. · select the Baud Rate and Flow Control that will communicate with the modem. · In the Dial-Out Se!ngs -- Always On Out-of-Band fields enter the access details for the remote PPP server to be called. The Override DNS sec!on is available for PPP Devices such as modems. Override DNS allows the use of alternate DNS servers from those provided by your ISP. For example, an alterna!ve DNS may be required for OpenDNS used for content filtering. To enable Override DNS: · check the Override returned DNS Servers checkbox. · Enter the IP address of the alterna!ve DNS servers in the DNS Server 1 and DNS Server 2 entry fields. · Click Apply. 4.3.2. Failover dial-out The ACM7000, ACM5500, ACM5000, CM7100, IM7200 and IM4200 series of advanced console servers can be configured so a dial-out PPP connec!on is automa!cally set up in the event of a disrup!on in the principal management network. Note: with firmware v3.0.1 and earlier, only SSH access is enabled on the failover connec#on. In later firmware versions 3.0.2 and later HTTPS access is also enabled. Once the dial-out PPP connec#on is established the administrator can connect to the console server via SSH (or HTTPS on console servers running firmware 3.0.2 or later) and fix the problem. Opengear User Manual. Page 109. When configuring the principal network connec!on in System > IP specify the Failover Interface to be used when a fault has been detected with Network or Network1 (that is, eth0). This can be either the Internal Modem, Dial Serial DB9 (if you are using an external modem on the console port), or USB Modem (if you are using a plug-on USB modem on an ACM7000, ACM5500 or ACM5000). · Set the Probe Addresses of two sites (the Primary and Secondary) that the IM console server is to ping to determine if Network or Network1 is s!ll opera!onal. · Navigate to System > Dial. · Select the port to be configured: Serial DB9 Port, PC Card, or Internal Modem Port. · Select the Baud Rate and Flow Control that will communicate with the modem. · Check the Enable Dial-Out Access checkbox. · In the Dial-Out Se!ngs -- Always On Out-of-Band fields enter the access details for the remote PPP server to be called. The Override DNS sec!on is available for PPP Devices such as modems. Override DNS allows the use of alternate DNS servers from those provided by your ISP. For example, an alterna!ve DNS may be required for OpenDNS used for content filtering. To enable Override DNS: · check the Override returned DNS Servers checkbox. · Enter the IP address of the alterna!ve DNS servers in the DNS Server 1 and DNS Server 2 entry fields. Opengear User Manual. Page 110. · Click Apply. Note: as of firmware v3.1.0 and later, the advanced console server, by default, supports automa#c failure-recovery back to the state extant prior to the failover. The advanced console server con#nually pings probe addresses whilst in original and failover states. The original state will automa#cally be set as a priority and reestablished following three successful pings of the probe addresses during failover. The failover state will be removed once the original state has been re-established. 4.4. OOB broadband ethernet access The ACM7000, ACM5500, ACM5000, CM7100, IM7200 and IM4200 family of advanced console servers have a second ethernet port which can be configured for alternate and OOB (out-of-band) broadband access. console server label indica"ng second ethernet port ACM5004-2, ACM5508-2-I/M and ACM5504-3-P CM7100 and ACM7000 IM4200-2 IM4216-34 and ACM5504-5-G(-W)-I) LAN2 NET2 Network 2 ETH-1 With two ac!ve broadband access paths to these advanced console servers, in the event you are unable to access through the primary management network (LAN1, Network or Network1) you can s!ll access it through the alternate broadband path. · Navigate to System > IP. · select Management LAN Interface (ACM5004-2, CM7100, IM7200, and IM4200). · configure the IP Address, Subnet Mask, Gateway and DNS with the access se$ngs that relate to the alternate link. Note: when configuring the principal Network Interface connec#on, the Failover Interface must be set to None. 4.5. Broadband ethernet failover The second Ethernet port on the ACM7000, ACM5500, ACM5000, CM7100, IM7200 and IM4200 family of advanced console servers can also be configured for failover to ensure transparent high availability. Opengear User Manual. Page 111. · Navigate to System > IP > Network Interface. · Select Management LAN from the Failover Interface pop-up menu. · Enter the Primary Probe Address and the Secondary Probe Address. These are the IP addresses or hostnames of the two hosts (the Primary and Secondary) that Opengear User Manual. Page 112. the advanced console server is to ping to determine if a Network Interface is s!ll opera!onal. · Select the Out-of-Band/Failover Interface tab. · Enter the Out-of-Band/Failover IP Address, Subnet Mask, and Gateway values. These values should be the same as used for the Network Interface. In this mode, the Management LAN Interface is available as the transparent back-up port to Network Interface for accessing the management network. Management LAN Interface will automa!cally and transparently take over the work of Network Interface, in the event Network Interface becomes unavailable for any reason. Note: In console servers running firmware v3.0.1 and earlier, only SSH access is enabled on the failover connec#on. In later firmware versions 3.0.2 and later HTTPS access is also enabled. Once the dial-out PPP connec#on is established the administrator can connect to the console server via SSH (or HTTPS on console servers running firmware 3.0.2 or later) and fix the problem. As of firmware v3.1.0 and later, the advanced console server, by default, supports automa!c failure-recovery back to the state extant prior to the failover. The advanced console server con!nually pings probe addresses whilst in original and failover states. The original state will automa!cally be set as a priority and reestablished following three successful pings of the probe addresses during failover. The failover state will be removed once the original state has been re-established. For firmware versions prior to v3.1.0 the advanced console server does not support automa!c failure-recovery back to the original state prior to the failover. To restore networking to a recovered state the following command then needs to be run: rm -f /var/run/*-failed-over && config -r ipconfig If required, you can run a custom bash script when the device fails over. It is possible to use this script to implement automa!c failure recovery, depending on your network setup. The script to create is: /etc/config/scripts/interface-failover-alert 4.6. Cellular modem connec"on The ACM7000, ACM5500, ACM5000, IM7200 and IM4200 family of advanced console servers support internal cellular modems. These modems first need to be installed (as documented in 4.6.1, 4.6.2 and 4.6.3 below) and then set up to validate they can connect to the carrier network (as documented 4.6.4 and 4.6.5 below). They then can be configured for opera!on in Always-on cellular router or OOB mode, or in Failover mode (as documented in 4.7 below). 4.6.1. Connec"ng to a GSM HSUPA/UMTS carrier network Console server models denoted with -G have an internal GSM modem that will connect to any major GSM carrier globally. Opengear User Manual. Page 113. Note: before powering on any -G model console server (for example, the ACM5004-G, ACM5004-G-I, ACM55044-5-G-I or the IM4200-X2-G), install the SIM card provided by your cellular carrier and a"ach the external aerial. Also, The ACM5004-G(-I) and ACM55044-5-G-I have two cellular status LEDs. The SIM LED on top of the unit should go on solid when a SIM card has been inserted and detected. · Navigate to System > Dial. · Click the Internal Cellular Modem tab. · Check the Enable Dial-Out radio bu%on in the Internal Cellular Modem Dial Se!ngs sec!on. Your carrier may have provided details for configuring the connec!on including: value APN descrip"on Access Point Name. Opengear User Manual. Page 114. PIN code If the carrier-provided SIM card is locked, a PIN Code may be required to unlock it. Phone Number the dial sequence which establishes the connec!on. By default this is *99***1#. Username Op!onal. Password Op!onal. Custom Modem Ini!aliza!on Op!onal AT command sequence to in!alize the modem. · Enter the carrier's APN. Example APNs include: carrier APN AT&T (USA) i2gold T-Mobile (USA) epc.tmobile.com Internode (Australia) internode Telstra (Australia telstra.internet Note: the APN is, in most cases, the only value needed. The other fields can be le( blank. · If the SIM Card is configured with a PIN Code, unlock the Card by entering the PIN Code. Note: if the PIN Code is entered incorrectly three #mes, the PUK Code will be required to unlock the Card. You may also need to use Override DNS to set alternate DNS servers from those provided by your carrier. If this is necessary: · On System > Dial > Internal Cellular Modem, check the Override returned DNS servers checkbox. · Enter the alterna!ve DNS servers in the DNS Server 1 and DNS Server 2 fields. · Click Apply. A radio connec!on will be established with your cellular carrier. 4.6.2. Connec"ng to a CDMA EV-DO carrier network Console server models denoted with -GV or -GS have an internal CDMA modem and will connect to the Verizon network in North America. A&er crea!ng an account with the CDMA carrier, some carriers require an addi!onal step to provision the Internal Cellular Modem, known as Provisioning. The ACM5004-GV and IM4200-DAC-X2 support · Over-the-Air Service Provisioning (OTASP) where modem-specific parameters can be retrieved via a voice call to a special phone number, and · a manual process where the phone number and other parameters are entered manually. OTASP Note: before this can be achieved, a working account and an ac#vated device are required. In this case an ac#vated device is an Opengear console server which has had its ESN (Electronic Opengear User Manual. Page 115. Serial Number) registered with an appropriate plan on your carrier's account. · Navigate to System > Dial. · Click the Internal Cellular Modem tab. · Enter the par!cular phone number which must be dialed to complete OTASP. For example, Verizon uses *22899 and Telus uses *22886. · Click Ac"vate. This ini!ates the OTASP call. The process is successful if no errors are displayed and you no longer see the CDMA Modem Ac!va!on form. If OTASP is unsuccessful consult the System Logs at Status > Syslog for clues to what went wrong. · When OTASP has completed enable the Internal Cellular Modem by entering the carrier's phone number By default, this number is #777. · click Apply. To confirm OTASP success, and to display the modem's current state: · navigate to Status> Sta"s"cs. · click the Cellular tab. The current state of the modem will present. OTASP success will result in a valid phone number being placed in the NAM Profile Account MDN field. Opengear User Manual. Page 116. Manual ac"va"on If a carrier does not support OTASP it will be necessary to manually provision the modem. · Navigate to System > Dial. · Click the Internal Cellular Modem tab. · Enter the MSL, MDN and MSID values. These values are specific to your carrier and for manual ac!va!on you will have to learn what values your carrier uses in each field. Verizon, for example, has been known to use an MSL of 000000 and the phone number assigned to the Opengear device as both the MDN and MSID with no spaces or hyphens. So an assigned phone number of 555-123-1234 is entered in the MDN and MSID fields as 5551231234. · Click Ac"vate. If no errors occur you will see the new values entered into the NAM Profile Account. To check this: · navigate to Status> Sta"s"cs. Opengear User Manual. Page 117. · click the Cellular tab. To connect to your carrier's 3G network: · navigate to System > Dial. · click the Internal Cellular Modem tab. · enter the appropriate Phone Number. This is usually #777. · If required by your account plan, enter the supplied Username and Password. · Check the Enable check-box. · click Apply. The Always On Out-of-Band connec!on is ini!ated. 4.6.3. Connec"ng to a 4G LTE carrier network Console server models denoted with -LV, -LA, or -LR have an internal modem that will connect to any major 4G LTE carrier globally. Note: before powering on any -LV, -LA, or -LR model console server, install the SIM card provided by your cellular carrier and a"ach the external aerial. · Navigate to System > Dial. · Click the Internal Cellular Modem tab. · Check the Enable Dial-Out radio bu%on in the Internal Cellular Modem Dial Se!ngs sec!on. Your carrier may have provided details for configuring the connec!on including: value descrip"on APN Access Point Name. PIN code If the carrier-provided SIM card is locked, a PIN Code is required to unlock it. Phone Number the dial sequence to establish the connec!on. By default this is *99***1#. Username Op!onal. Opengear User Manual. Page 118. Password Op!onal. · Enter the carrier's APN. Example APNs include: carrier APN AT&T (USA) i2gold T-Mobile (USA) epc.tmobile.com Internode (Australia) internode Telstra (Australia telstra.internet Note: the APN is, in most cases, the only value needed. The other fields can be le( blank. · If the SIM Card is configured with a PIN Code, unlock the Card by entering the PIN Code. Note: if the PIN Code is entered incorrectly three #mes, the PUK Code will be required to unlock the Card. You may also need to use Override DNS to set alternate DNS servers from those provided by your carrier. If this is necessary: · On System > Dial > Internal Cellular Modem, check the Override returned DNS servers checkbox. · Enter the alterna!ve DNS servers in the DNS Server 1 and DNS Server 2 fields. · Click Apply. A radio connec!on will be established with your cellular carrier. 4.6.4. Verifying the cellular connec"on Out-of-band access is enabled by default so the cellular modem connec!on should now be on. To verify this: · navigate to Status > Sta"s"cs. · select the Cellular tab. · verify the Mode is set to Online. · select the Failover & Out-of-Band tab. Opengear User Manual. Page 119. · verify the Connec"on Status reads as Connected. To measure the received signal strength: · navigate to Status > Sta"s"cs. The current state of the cellular modem, including the Received Signal Strength Indicator (RSSI), will present. Note the RSSI coverage value. value descrip"on -100 dBm unacceptable -99 to -90 dBm weak-to-medium value descrip"on -89 to -70 dBm medium-to-strong -69 dBm very strong RSSI is a measure of the Radio Frequency (RF) power present in a received radio signal. It is generally expressed in decibel-milliwa%s (dBm). The best throughput comes from placing the receiving device in a loca!on with the highest possible RSSI. With the cellular modem connec!on on the connec!on status is also visible via the LEDs on top of console server. Note: The ACM5004-G/LR(-I), ACM5504-5-G(-W)-I and ACM5504-5-LA/R/V-I each have two cellular status LEDs. The WWAN LED is OFF when in reset mode or not powered. When powered it will go ON and while searching for service it will flash off briefly every five seconds. 4.6.5. Cellular modem watchdog As of with firmware V3.5.2u13 and later, when you check the Enable Dial-Out check-box at System > Dial, you will be given the op!on to configure a cellar modem watchdog service. Opengear User Manual. Page 120. This service will periodically ping a configurable IP address. If a threshold number of consecu!ve a%empts fail, the service will cause the unit to reboot. This can be used to force a clean restart of the modem and its services to work around any carrier issues. 4.6.6. Dual-SIM failover Some console server models (as of 2016/11, the ACM5500-Gx and ACM5500Lx families) allow you to insert two SIM cards, allowing for selec!ve connec!on to two carrier networks. The dual-SIM failover feature allows the cell modem to selec!vely failover to the secondary SIM when communica!on over the primary SIM fails. To configure dual-SIM failover: · navigate to System > Dial. · click the Internal Cellular Modem tab. · in the SIM Configura"on sec!on, set the Primary SIM to either Bo$om Slot or Top Slot. Choose the slot which contains the SIM from your primary carrier network. · vheck the Enable SIM Failover checkbox. · specify how the device will failback from the failover SIM to the Primary SIM. There are two op!ons: On Disconnect. With this op!on the console server will failback to the Primary SIM only a&er the connec!on on the failover SIM has failed its ping test. On Timeout. With this op!on, the console server will failback to the Primary SIM a&er the connec!on on the failover SIM has been up for the !meout period. · if On Timeout is the selected failback op!on, set the Failback Timout value. The Failback Timout is the number of seconds the failover SIM must be connected before the console server switches back to the Primary SIM. If no number is entered here, the default value of 600 seconds (10 minutes) applies. · configure each SIM connec!on with the informa!on necessary (APN, and, if required, the PIN, Phone Number, Username and Password) to enable it to make a successful connec!on, assuming sufficient signal strength from the cell service provider. See 4.6.1, 4.6.2, and 4.6.3 above for details. · enter a Failback Test IP address for each SIM. This IP address is used to ping test the status of the cell modem connec!on and to determine if SIM failover or failback is to take place. · op!onally configure DDNS and the Modem Watchdog (see chapter 4.6.5). DDNS, when configured, will be applied to the cell modem dial out connec!on regardless of which SIM is currently in use. Note: dual-SIM failover is for dial out connec#ons only. Opengear User Manual. Page 121. 4.6.7. Mul"-carrier cellular support Some cellular carriers require the console server's cellular modem to be programmed with carrier-specific firmware to operate on their network. Some console server models, however, are equipped with a reprogrammable cellular modem, allowing them to operate on more than one such carrier network. Note: changes to the cellular modem firmware are unaffected by Opengear firmware upgrades or factory erase/configura#on reset opera#ons. On console servers with mul!-carrier capability: · navigate to System > Dial. · select the Internal Cellular Modem tab. The Internal Cellular Modem Carrier Se!ngs sec!on (which provides control over which carrier's firmware is installed on the modem) will present. · select the desired Carrier radio bu%on. The modem's flash memory will have the carrier-specific firmware image installed. Flashing takes several minutes during which the cellular modem is unavailable. During this !me, the page periodically refreshes with status informa!on. Upon successful comple!on, the page displays the message: Cellular Firmware carrier change completed. Mul!-carrier capable models ship with cellular modem firmware for each supported carrier pre-loaded onto internal non-vola!le or USB storage. Periodically, new cellular modem firmware becomes available and is published on the Opengear downloads site. Note: if your unit's cellular connec#on is opera#ng correctly, there is typically no need to upgrade its cellular firmware. On console servers with mul!-carrier capablity, to download and apply new cellular firmware using the Management Console UI: · navigate to System > Firmware. A sec!on presents showing the local cellular firmware image status and a Check for Update bu%on that starts the firmware update process. The Cellular Firmware Status sec!on indicates the date of the last firmware download, and shows a cryptographic fingerprint. This can be used to verify the local files' integrity against the fingerprint published in the Opengear Knowledge Base. Opengear User Manual. Page 122. · click the Check for Update bu%on. The Management Console contacts the remote server, &p://&p.opengear.com/, and displays an update summary. This summary indicates the local and remote fingerprints for comparison, without altering any local files. · op!onally, expand the Advanced sec!on. This sec!on shows a full list of files to be downloaded or deleted, along with their SHA1 hashes. (Temporary files downloaded during the in!al Check for Updates may be listed as simple files to copy into place, as they do not have to be re-downloaded.) · click Download and Apply. Note: the modem will only be flashed if new firmware is available for the currently selected carrier. During the download and flashing of the firmware, an inters!!al screen displays, showing Currently upgrading cellular modem firmware. Once completed the status of the firmware update is displayed at System > Firmware. · alterna!vely, click Cancel to reject the update. It is also possible to control mul!-carrier features at the console server shell. · Show currently selected carrier. cellctl -is | egrep "^preferred-carrier" | cut -d " " -f 2 · Show current modem firmware version. cellctl -is | egrep "^current-firmware" | cut -d " " -f 2 · List available carriers supported on installed modem. /etc/scripts/cell-fw-update -l · Check for availability of firmware updates. /etc/scripts/cell-fw-update -u Output is the remote fingerprint followed by the list of ac!ons that would be taken by cell-fw-update -d. · Download latest firmware for all carriers supported by the modem. /etc/scripts/cell-fw-update -d · Flash modem with latest local firmware for carrier. /etc/scripts/cell-fw-update -c <carrier> <carrier> is one of the carrier iden!fiers emi%ed by cell-fw-update -l. This command can be used to switch carriers or to update the firmware of the current carrier. Note: if the firmware version informa#on on the modem is iden#cal, the modem may reject the update without error. Opengear User Manual. Page 123. 4.7. Cellular opera"on When set up as a console server, the 3G cellular modem can be set up to connect to the carrier in one of four mode. OOB mode. In this mode the dial-out connec!on to the carrier cellular network is always on, awai!ng incoming access from a remote site wan!ng to access to the console server or a%ached serial consoles/network hosts. Failover mode. In this mode a dial-out cellular connec!on is only established in event of a ping failure. Cellular router mode. In this mode, the dial-out connec!on to the carrier cellular network is always on, and IP traffic is routed between the cellular connected network and the console server's local network ports. This is the default mode of opera!on for ACM5000-G and ACM5500-L and ACM5500-G models. Circuit Switched Data (CSD) mode. In this dial-in mode, the cellular modem can receive incoming calls from remote modems who dial a special Data Termina!ng number. This is a 3Gonly mode. 4.7.1. OOB access set-up In this mode the dial-out connec!on to the carrier cellular network is always on, awai!ng any incoming traffic. By default, the only traffic enabled is incoming SSH access to the console server and its serial ports, and incoming HTTPS access to the console server. There is a low level of keep alive and management traffic going over the cellular network. Generally, however, the status reports, alerts and other traffic from the site can be carried over the main network. This mode is typically used for out of band access to remote sites. Consequently, to be directly accessed, the appliance needs to have a Public IP address and it must not have SSH access firewalled. This OOB mode is the default for IM7200 and IM4200 appliances with internal cellular modems. Out-of-band access is enabled by default and the cellular modem connec!on is always on. Almost all carriers offer corporate mobile data service/plans with a Public (sta!c or dynamic) IP address. These plans do, however, o&en have a service fee a%ached. With a sta!c Public IP address plan you can try accessing the console server using the Public IP Address provided by the carrier. By default, however, only HTTPS and SSH access is enabled on the OOB connec!on: you can browse to the console server, but you cannot ping it. With a dynamic Public IP address plan, a DDNS service will need to be configured to allow the remote administrator to ini!ate incoming access. Once this is done you can then also try accessing the console server using the allocated domain name. By default, most providers offer a consumer-grade service which provides dynamic Private IP address assignments to 3G devices. This IP address is not visible across the Internet but generally it is adequate for home and general business use. To confirm a consumer-grade service: · Navigate to the Status > Sta"s"cs. · Click the Failover & Out-of-Band tab. Opengear User Manual. Page 124. · In the Always on Out-of-Band -- Internal Cellular Modem (cellmodem) sec!on, check the value presented for IP Address. If the value is in one of the private IP Address ranges -- 10.0.0.0 10.255.255.255 172.16.0.0 172.31.255.255 192.168.0.0 192.168.255.255 -- you have a consumer-grade cellular service. For inbound OOB connec!on with such a plan you will need to use Call Home with a Lighthouse/VCMS/CMS6110 or set up a VPN. In Out of Band access mode, the internal cellular modem will con!nually stay connected. The alterna!ve is to set up Failover mode on the console server as detailed in the next sec!on. 4.7.2. Cellular failover In this mode a dial-out cellular connec!on is only established in event of disrup!on to the main network. The cellular connec!on normally remains idle and in a low power state. It is only ac!vated in event of a ping failure. This standby mode suits remote sites with expensive power or high cellular traffic costs. In this mode, the appliance con!nually pings nominated probe addresses over the main network connec!on. In the event of ping failure it dials out and sets up a dial-out ppp connec!on over the cellular modem and access is switched transparently to this network connec!on. Then when the main network connec!on is restored, access is switched back. Once you have configured the carrier connec!on, the cellular modem can be configured for failover. This will tell the cellular connec!on to remain idle in a low power state. If the primary and secondary probe addresses are not available it will bring up the cellular connec!on and connect back to the cellular carrier. · Navigate to System > IP. Opengear User Manual. Page 125. · Select Internal Cellular Modem (cellmodem01) from the Failover Interface pop-up menu. · Enter the Primary Probe Address and the Secondary Probe Address. These are the two sites the console server pings to determine if the principal network is opera!onal. In event of principal network failure the cellular network connec!on is ac!vated as the access path to the console server and any managed devices. Note: only HTTPS and SSH access are enabled on the failover connec#on. This allows an administrator to connect to the console server to diagnose and correct the network failure without offering third-par#es a large a"ack surface. As of firmware v3.1.0, the advanced console server supports automa!c failure-recovery back to the original state prior to failover by default. The advanced console server con!nually pings probe addresses whilst in original and failover states. The original state will automa!cally be set as a priority and re-established following three successful pings of the probe addresses during failover. The failover state will be removed once the original state has been re-established. For earlier firmware, which does not support automa!c failure-recovery, to restore networking to a recovered state the following command then needs to be run: rm -f /var/run/*-failed-over && config -r ipconfig If required, you can run a custom bash script when the device fails over. It is possible to use this script to implement automa!c failure recovery, depending on your network setup. The script to create is: /etc/config/scripts/interface-failover-alert To check the connec!on status: · navigate to Status > Sta"s"cs. · click the Failover & Out-of-Band tab. · Note the Ac"ve Connec"on value. If the Main Connec"on is good, the Ac"ve Connec"on value will be Main. Opengear User Manual. Page 126. If the Main Connec"on is down, the Out-of-Band/Failover sec!on displays informa!on rela!ng to a configured Out-of-Band/Failover interface and the status of that connec!on. The IP Address of the Out-of-Band/Failover interface will be presented in the Out-ofBand/Failover sec!on once the Out-of-Band/Failover connec!on has been triggered and made. 4.7.3. Cellular rou"ng Once you have a configured carrier connec!on, the cellular modem can be configured to route traffic through the console server. This requires se$ng up forwarding and masquerading as detailed in chapter 4.8. 4.7.4. Cellular CSD dial-in CSD is a legacy form of data transmission developed for TDMA-based mobile phone systems like GSM. CSD uses a single radio !me slot to deliver 9.6kb/s data transmission to the GSM Network and Switching Subsystem where it could be connected through the equivalent of a normal modem to the Public Switched Telephone Network (PSTN) allowing direct calls to any dial-up service. CSD is provided selec!vely by carriers and it is important you receive a Data Termina!ng number as part of the mobile service your carrier provides. This is the number which external modems will call to access the console server. Once you have configured carrier connec!on, the cellular modem can be configured to receive Circuit Switched Data (CSD) calls. · Navigate to System > Dial. · Click the Internal Cellular Modem tab. · Check the Enable Dial-In radio bu%on. · Enter the required informa!on in the Dial-In Se!ngs sec!on. 4.8. Firewalls & forwarding Console servers with firmware v3.3 and later have basic rou!ng, NAT (Network Address Transla!on), packet filtering and port forwarding support on all network interfaces. This enables the console server to func!on as an Internet or external network gateway, via cellular connec!ons or via other Ethernet networks on two Ethernet port models. Network Forwarding allows the network packets on one network interface (for example LAN1 aka eth0) to be forwarded to another network interface (for example, LAN2 or dial-out/ cellular). So locally networked devices can IP connect through the console server to devices on remote networks. Opengear User Manual. Page 127. IP Masquerading is used to allow all the devices on your local private network to hide behind and share the one public IP address when connec!ng to a public network. This type of transla!on is only used for connec!ons origina!ng within the private network des!ned for the outside public network, and each outbound connec!on is maintained by using a different source IP port number. When using IP Masquerading, devices on the external network cannot ini!ate connec!ons to devices on the internal network. Port Forwards allows external users to connect to a specific port on the external interface of the console server and be redirected to a specified internal address for a device on the internal network. With Firewall Rules, packet filtering inspects each packet passing through the firewall and accepts or rejects it based on user-defined rules. Then Service Access Rules can be set for connec!ng to the console server/router itself. Opengear User Manual. Page 128. 4.8.1. Configuring network forwarding & IP masquerading To use a console server as an Internet or external network gateway requires establishing an external network connec!on (for example, for the ACM5004-G it means se$ng up the 3G cellular link as detailed in chapter 4) and then se$ng up forwarding and masquerading. By default, all console server models are configured so that they will not route traffic between networks. To use the console server as an Internet or external network gateway, forwarding must be enabled so that traffic can be routed from the internal network to the Internet or an external network. Note: Network forwarding allows the network packets on one network interface (for example, LAN1/eth0) to be forwarded to another network interface (for example LAN2/eth1 or dialout/cellular). Locally networked devices can IP-connect through the console server to devices on a remote network. IP masquerading is used to allow all the devices on your local private network to hide behind and share the one public IP address when connec#ng to a public network. This type of transla#on is only used for connec#ons origina#ng within the private network des#ned for the outside public network, and each outbound connec#on is maintained by using a different source IP port number. · Navigate to System > Firewall. · Select the Forwarding & Masquerading tab. · Find the Source Network to be routed and !ck the relevant Des"na"on Network. For example, to configure a single-Ethernet device such as the ACM5004-G as a cellular router set: the Source Network to Network Interface the Des"na"on Network to Dialout/Cellular. IP Masquerading is generally required if the console server will be rou!ng to the Internet, or if the external network being routed to does not have rou!ng informa!on about the internal network behind the console server. IP Masquerading performs Source Network Address Transla!on (SNAT) on outgoing packets, to make them appear like they've come from the console server rather than devices on the Opengear User Manual. Page 129. internal network. When response packets come back devices on the external network, the console server translates the packet address back to the internal IP, so that it is routed correctly. This allows the console server to provide full outgoing connec!vity for internal devices using a single IP Address on the external network. By default IP Masquerading is disabled for all networks. To enable masquerading: · navigate to System > Firewall. · select the Forwarding & Masquerading tab. · check Enable IP Masquerading (SNAT) on the network interface where masquerading is to be enabled. 4.8.2. Configuring client devices Client devices on the local network must be configured with Gateway and DNS se$ngs. This can be done sta!cally on each device, or, in IM- and ACM-series devices, using DHCP. Manual configura"on Manually set a sta!c gateway address (being the address of the console server) and set the DNS server address to be the same as used on the external network. That is, if the console server is ac!ng as an internet gateway or a cellular router, use the ISP-provided DNS server address. DHCP configura"on Note: DHCP configura#on is only available on IM- and ACM-series devices. · Navigate to System > IP. · Click the tab of the interface connected to the internal network. · To use DHCP, a sta!c address must be set: check that the IP Address and Subnet Mask fields Opengear User Manual. Page 130. have specific and sta!c values entered. · Click the Disabled link adjacent the DHCP Server entry. System > DHCP Server will load. · Check the DHCP Server checkbox. · Check the Use interface address as gateway checkbox. · Set the Primary DNS and Secondary DNS addresses to the same addresses as are used on the external network. That is, if the console server is ac!ng as an internal gateway or a cellular router, use the ISPprovided DNS server addresses. · Enter the Default Lease !me in seconds. · Enter the Maximum Lease !me in seconds. Least !mes are the number of seconds a dynamically assigned IP address is valid before the client must request it again. · click Apply. The DHCP server issue IP addresses sequen!ally from a specified address pool or pools. · Click Add in the Dynamic Address Alloca"on Pool sec!on. Opengear User Manual. Page 131. · Enter the DHCP Pool Start Address. · Enter the DHCP Pool End Address. · click Apply. 4.8.3. Port & protocol forwarding When using IP Masquerading, devices on the external network cannot ini!ate connec!ons to devices on the internal network. To work around this, Port Forwards can be set up to allow external users to connect to a specific port, or range of ports on the external interface of the console server or cellular router. Port forwarding also allows the console server or cellular router to redirect data to a specified internal address and port range. To setup a port and protocal forward: · navigate to System > Firewall. · click the Port/Protocol Forwarding tab. · Click New Port/Protocol Forward. Opengear User Manual. Page 132. · Fill in the following fields. field Name Input Interface Source Address/Address Range purpose Name for the port forward. This should describe the target and the service that the port forward is used to access. This allows the user to only forward the port from a specific interface. In most cases, this should be le& as Any. This allows the user to restrict access to a port forward to a specific source IP address or IP address range of the data. This may be le& blank. IP address ranges use the format ip/netmask (where netmask is in bits 1-32). For example, to forward port 8443 to an internal HTTPS server on 192.168.10.2, use the following se$ngs: field value Name Administrator's choice. Input Interface Any Source Address/Address Range Leave blank. Des!na!on Address/Address Range Leave blank. Input Port Range 8443 Protocol TCP Output Address 192.168.10.2 Output Port Range 443 4.8.4. Firewall rules Firewall rules can be used to block or allow traffic through an interface based on port number, the source IP address, the des!na!on IP address or range, the direc!on (ingress or egress), the protocol or any combina!on of these. This can be used to allow custom on-box services, Opengear User Manual. Page 133. or block traffic based on policy. To setup a firewall rule: · navigate to System > Firewall. · click the Firewall Rules tab. Note: prior to firmware v3.4 this tab was labeled Port Rules and fewer firewall rules could be configured. · Click New Firewall Rule. · Fill in the following fields. field purpose Name Interface Port Range Source MAC Address Source Address Range Des!na!on Range Protocol Direc!on Ac!on Name the rule. This name should describe the policy the firewall rule is being used to implement (for example, Block FTP or Allow Tony). Select the interface that the firewall rule will be applied to. Choices include Any, Dialout/Cellular, VPN, Network Interface, and Dial-in. Specify the Port or range of Ports (for example 1000 1500) that the rule will apply to. This may be le& blank for Any. Specify the source MAC address to be matched. This may be le& blank for Any. MAC addresses use the format XX:XX:XX:XX:XX:XX, where XX are hex digits. Specify the source IP address (or address range) to match. IP address ranges use the format ip/netmask (where netmask is in bits 1-32). This may be le& blank for Any. Specify the des!na!on IP address/address range to match. IP address ranges use the format ip/netmask (where netmask is in bits 1-32). This may be le& blank. Select if the firewall rule will apply to TCP, UDP, TCP and UDP, ICMP, ESP, GRE, or Any. Select the traffic direc!on that the firewall rule will apply to: Ingress = incoming; Egress = outgoing. Select the ac!on (Accept or Block) to be applied to the packets detected that match the Interface + Port Range + Source Address + Des!na!on Range+ Protocol+ Direc!on. For example, to block all SSH traffic from leaving Dialout Interface, use the following se$ngs: field Name Interface Port Range Source MAC Address value Administrator's choice. Dialout/Cellular 22 Le& blank. Opengear User Manual. Page 134. Source Address Range Des!na!on Range Protocol Direc!on Ac!on Le& blank (Any). Le& blank. TCP Egress Block Firewall rules are processed in a set order, from top to bo%om. So rule placement is important. For example with the following rules, all traffic coming in over the Network Interface is blocked except when it comes from two nominated IP addresses (SysAdmin and Tony): field allow SysAdmin allow Tony Block Everyone Else Interface Any Any Network Interface Port Range Any Any Any Source MAC Address Any Any Any Source Address Range SysAdmin's IP address Tony's IP address Any Des!na!on Range Any Any Any Protocol Direc!on Ac!on TCP Ingress Accept TCP Ingress Accept TCP Ingress Block If the Rule Order is changed so the Block Everyone Else rule was second on the list, Tony's traffic -- coming in over the Network Interface -- would be blocked. Opengear User Manual. Page 135. 5.SSH tunnels & SDT connector Each Opengear console server has an embedded SSH server and uses SSH tunneling so remote users can securely connect through the console server to Managed Devices using text-based console tools (such as SSH, telnet, SoL) or graphical tools (such VNC, RDP, HTTPS, HTTP, X11, VMware, DRAC, iLO). The Managed Devices being accessed can be located on the same local network as the console server or they can be a%ached to the console server via a serial port. The remote User/Administrator connects to the console server thru an SSH tunnel via dial-up, wireless or ISDN modem; a broadband Internet connec!on; the enterprise VPN network or the local network: Opengear User Manual. Page 136. To set up the secure SSH tunnel from the Client PC to the console server, you must install (if necessary) and launch SSH client so&ware on the User's or Administrator's PC. Opengear recommends you use the SDT Connector client so&ware that is supplied with the console server for this. SDT Connector is simple to install and auto-configure and it will provides all your users with point-and-click access to all the systems and devices in the secure network. With one click, SDT Connector sets up a secure SSH tunnel from the client to the selected console server, then establishes a port forward connec!on to the target network connected host or serial connected device, then executes the client applica!on that will be used in communica!ng with the host. This chapter details the basic SDT Connector opera!ons: · Configuring the console server for SSH tunneled access to network a%ached hosts and se$ng up permi%ed Services and user access. · Se$ng up the SDT Connector client with gateway, host, service and client applica!on details and making connec!ons between the Client PC and hosts connected to the console server. · Using SDT Connector to browser access the Management Console. · Using SDT Connector to Telnet or SSH connect to devices that are serially a%ached to the console server. The chapter then covers more advanced SDT Connector and SSH tunneling topics: · Using SDT Connector for out of band access. · Automa!c impor!ng and expor!ng of configura!ons. · Configuring Public Key Authen!ca!on. · Se$ng up a SDT Secure Tunnel for Remote Desktop. · Se$ng up a SDT Secure Tunnel for VNC. · Using SDT to IP connect to hosts that are serially a%ached to the console server. 5.1. Configuring for SSH tunnelling to hosts To set up the console server for SSH tunneled access a network a%ached host: · Add the new host and the permi%ed services using the Serial & Network > Network Hosts menu as detailed in Network Hosts (chapter 3.4). Only these permi%ed services will be forwarded through by SSH to the host. All other services (TCP/UDP ports) will be blocked. · following are some of the TCP Ports used by SDT in the console server: port applica"on 22 SSH 23 Telnet 80 HTTP 3389 RDP notes All SDT tunneled connec!ons. On local LAN. Forwarded inside tunnel. On local LAN. Forwarded inside tunnel. On local LAN. Forwarded inside tunnel. Opengear User Manual. Page 137. 5900 VNC On local LAN. Forwarded inside tunnel. 73xx RDP over serial From local LAN. xx is the serial port # (eg 73017348 on a 48-port console server. 79xx VNC over serial From local LAN. xx is the serial port # (eg 73017348 on a 48-port console server. · Add the new Users using Serial & Network > Users & Groups menu as detailed in Network Hosts (chapter 3.4). Users can be authorized to access the console server ports and specified network-a%ached hosts. To simplify configura!on, the Administrator can first set up Groups with group access permissions, then Users can be classified as members of par!cular Groups. 5.2. SDT connector client configura"on The SDT Connector client works with all Opengear console servers. Each of these remote console servers has an embedded OpenSSH based server which can be configured to port forward connec!ons from the SDT Connector client to hosts on their local network, as detailed in the previous chapter. The SDT Connector can also be pre-configured with the access tools and applica!ons that will be available to be run when access to a par!cular host has been established. SDT Connector can connect to the console server using an alternate OOB access. It can also access the console server itself and access devices connected to serial ports on the console server. 5.2.1. SDT connector client installa"on The SDT Connector set up program, SDTConnector Setup-1.n.exe or sdtcon-1.n.tar.gz, is included on the CD supplied with your Opengear console server product. Alterna!vely a copy can be freely download from Opengear's website. To install, run the set-up program. For Windows clients, SDTConnectorSetup-1.n.exe applica!on will install SDT Connector 1.n.exe and the config file defaults.xml. If there is already a config file on Opengear User Manual. Page 138. the Windows PC it will not be overwri%en. To remove earlier config file run the regedit command, search for "SDT Connector" and remove the directory with this name. For Linux and other Unix clients, SDTConnector.tar.gz will install the sdtcon-1.n.jar and the config file defaults.xml. Once the installer completes you will have a working SDT Connector client installed on your machine and an icon on your desktop. To launch the SDT Connector client, double-click this icon. Note: SDT Connector is a Java applica#on so it must have a Java Run#me Environment (JRE) installed. It will install on Windows 2000 and later and on most Linux pla'orms. Solaris pla'orms are also supported however they must have Firefox installed. SDT Connector can run on any system with Java 1.4.2 and above installed, but it assumes the web browser is Firefox, and that xterm -e telnet opens a telnet window. To operate SDT Connector, you first need to add new gateways to the client so&ware by entering the access details for each console server (see chapter 5.2.2) then let the client autoconfigure with all host and serial port connec!ons from each console server (see sec!on 5.2.3) then point-and-click to connect to the Hosts and serial devices (see chapter 5.2.4). Alternately you can manually add network connected hosts (see chapter 5.2.5) and manually configure new services to be used in accessing the console server and the hosts (see chapter 5.2.6) then manually configuring clients to run on the PC that will use the service to connect to the hosts and serial port devices (see chapter 5.2.7). SDT Connector can also be set up to make an out-of-band connec!on to the console server. 5.2.2. Configuring a new gateway in the SDT connector client To create a secure SSH tunnel to a new console server: Opengear User Manual. Page 139. · select File > New Gateway or click the New Gateway icon. · enter the IP address or hostname of the console server. · enter the SSH port (typically port 22). If SDT Connector is connec!ng to a remote console server through the public Internet or a routed network you will need to: · determine the public IP address of the console server or the public IP address of the router or firewall that connects the console server to the Internet. One way to find the public IP address is to access / or / from a computer on the same network as the console server and note the reported IP address. · Setup port-forwarding for TCP port 22 on any firewall, router or NAT service located between SDT Connector and the console server. h%p://www.por*orward.com/ has port-forwarding instruc!ons for a range of routers. The Open Port Check tool from h%p://www.canyouseeme.org/ can be used to check if portforwarding through a firewall, router or NAT service has been properly configured. · enter the Username and Password of a user on the gateway who has been enabled to connect via SSH. · op!onally, enter a Descrip"ve Name to display instead of the IP address or hostname. · op!onally enter desired informa!on in the Descrip"on/Notes field. For example: the console server's site loca!on; the console server's running firmware version; or details on the site's network configura!on. · click OK. The new gateway will appear in the SDT Connector home page. Note: For an SDT Connector user to access a console server and then access specific hosts or serial devices connected to that console server, that user must first be setup on the console server, and must be authorized to access the specific ports on the specific hosts (see chapter 4). Only these permi"ed services will be forwarded through by SSH to the Host. All other services (TCP/UDP ports) are blocked. 5.2.3. Auto-configure SDT connector client with the user's access privileges Each user on the console server has an access profile which has been configured with those specific connected hosts and serial port devices the user has authority to access, and a specific set of the enabled services for each of these. This configura!on can be auto-uploaded into the SDT Connector client. · Select File > New Gateway (or click the New Gateway icon). · Click Retrieve Hosts. SDT Connector will: · configure access to network connected Hosts that the user is authorized to access and will, for each of these Hosts, set up the services (for example, HTTPS, IPMI2.0) and the related Opengear User Manual. Page 140. IP ports being redirected. · configure access to the console server itself. This is shown as a Local Services host. · configure access with the enabled services for the serial port devices connected to the console server. Note: Retrieve Hosts auto-configures all classes of user whether they are members of user, admin, some other group, or no group. SDT Connector will not, however, auto-configure the root. Further, it is recommended that root only be used for ini#al config and for adding an ini#al admin account to the console server. 5.2.4. Make an SDT connec"on through the gateway to a host · Select the host to be accessed. · Click the Service to be used in accessing that host. The SSH tunnel to the gateway is established, the appropriate ports redirected through to the host, and the appropriate local client applica!on is launched poin!ng at the local endpoint of the redirec!on. The SDT Connector client can be configured with an unlimited number of gateways and each gateway can be configured to port forward to an unlimited number of locally networked Hosts. Similarly there is no limit on the number of SDT Connector clients who can be Opengear User Manual. Page 141. configured to access the one Gateway. Nor are there limits on the number of Host connec!ons that an SDT Connector client can concurrently have open through the one Gateway tunnel. However there is a limit to the number of SDT Connector SSH tunnels that can be open at the one !me on a par!cular Gateway. IM4200, ACM5000 and ACM5500 models each support at least 50 such concurrent connec!ons. So for a site with a IM4200 gateway you can have, at any !me up to 50 users securely controlling an unlimited number of network a%ached computers and appliances (servers, routers, etc.) at that site. ACM7000, IM7200 and CM7100 support many hundreds of simultaneous client tunnels. 5.2.5. Manually adding a host to the SDT connector gateway For each gateway, you can manually specify the network connected hosts that will be accessed through that console server; and for each host, specify the services that will used in communica!ng with the host. · Select File > New Host (or select a gateway and click the Host icon). Opengear User Manual. Page 142. · Enter the IP address or hostname of the host. Note: a hostname must be resolvable by the gateway. · Select which Services are to be used in accessing the new host. A range of service op!ons are pre-configured in the default SDT Connector client (RDP, VNC, HTTP, HTTPS, Dell RAC, VMware etc). If you wish to add services beyond the preconfigured range, proceed to the next sec!on then return here. · Op!onally, enter a Descrip"ve Name to display instead of the IP address or hostname. · Op!onally enter desired informa!on in the Descrip"on/Notes field. For example: the console server's site loca!on; the console server's running firmware version; or details on the site's network configura!on. · Click OK. 5.2.6. Manually adding new services to the new hosts To extend the range of services that can be used when accessing hosts with SDT Connector: · select Edit > Preferences. · click the Services tab. · Click Add. · enter a Service Name. · click Add. · under the General tab, enter the TCP Port that this service runs on (for example, port 80 for HTTP). · op!onally, select the client to use to access the local endpoint of the redirec!on. · select which client applica!on is associated with the new service. A range of client applica!on op!ons are pre-configured in the default SDT Connector (RDP client, VNC client, HTTP browser, HTTPS browser, Telnet client etc). However if you wish to add new client applica!ons to this range proceed to the next sec!on then return here. Opengear User Manual. Page 143. · Click OK. · Click Close. A service typically consists of a single SSH port redirec!on and a local client to access it. However it may consist of several redirec!ons; some or all of which may have clients associated with them. An example is the Dell RAC service. The first redirec!on is for the HTTPS connec!on to the RAC server. It has a client associated with it (web browser) that is launched immediately upon clicking the bu%on for this service. The second redirec!on is for the VNC service that the user may choose to later launch from the RAC web console. It automa!cally loads in a Java client served through the web browser, so it does not need a local client associated with it. On the Add Service screen you can click Add as many !mes as needed to add mul!ple new port redirec!ons and associated clients. You may also specify Advanced port redirec!on op!ons: · enter the local address to bind to when crea!ng the local endpoint of the redirec!on. It is not usually necessary to change this from localhost. Opengear User Manual. Page 144. · enter a local TCP port to bind to when crea!ng the local endpoint of the redirec!on. If this is le& blank, a random port will be selected. Note: SDT Connector can also tunnel UDP services. SDT Connector tunnels the UDP traffic through the TCP SSH redirec#on, so in effect it is a tunnel within a tunnel. Enter the UDP port on which the service is running on the host. This will also be the local UDP port that SDT Connector binds as the local endpoint of the tunnel. For UDP services, you s#ll need to specify a TCP port under General. This will be an arbitrary TCP port that is not in use on the gateway. An example of this is the SOL Proxy service. It redirects local UDP port 623 to remote UDP port 623 over the arbitrary TCP port 6667. 5.2.7. Adding a client program to be started for the new service Clients are local applica!ons that may be launched when a related service is clicked. To add to the pool of client programs: · select Edit > Preferences. · click the Client tab. · click Add. · enter a Client name. · enter the Path to the client executable file or click Browse to locate the client applica!on. · enter a Command line format for client executable associated with launching the client. SDT Connector typically launches a client using command line arguments to point it at the local endpoint of the redirec!on. Three keywords specify the command line format. When launching the client, SDT Connector subs!tutes these keywords with appropriate values. keyword descrip"on %path% The path to the executable file. Takes the previous field value: Path to the client executable file. Opengear User Manual. Page 145. %host% %port% The local address to which the local endpoint of the redirec!on is bound. That is, the Local Address field for the Service redirec!on Advanced op!ons. The local port to which the local endpoint of the redirec!on is bound. That is the Local TCP Port field for the Service redirec!on Advanced op!ons. If port is unspecified (Any) an appropriate randomly selected port is subs!tuted. For example, SDT Connector is preconfigured for Windows with an HTTP client that connects to the Windows user's default browser. If there is no default browser Firefox is used. Some clients are launched in a command line or terminal window. The Telnet client for example. In this case, Path to client executable file is telnet and the Command line format for client executable is cmd /c start %path% %host% %port%. · Click OK. 5.2.8. Dial-in configura"on If the client is dialing into the console server's Local/Console port, setup a dial-in PPP link. Opengear User Manual. Page 146. · Configure the console server for dial-in access, following the steps in chapter 4.1. · Set up the PPP client so&ware on the remote computer, following the steps in chapter 4. Once you have a dial-in PPP connec!on established, set up the secure SSH tunnel from the remote computer to the console server. 5.3. SDT connector to management console SDT Connector can also be configured for browser access to the gateway's Management Console and for Telnet or SSH access to the gateway's shell. For these connec!ons to the gateway itself, you must configure SDT Connector to access the gateway by se$ng the console server up as a host, and then configuring the appropriate services. · Launch SDT Connector on your PC. · Assuming you have already set up the console server as a Gateway in your SDT Connector client (with username, password etc) select this newly added Gateway and click the Host icon to create a host. · Alterna!vely, select File > New Host. · Enter 127.0.0.1 as the Host Address. · Op!onally add details in the Descrip"ve Name and Descrip"on/Notes fields. · Click OK. · Click the HTTP or HTTPS services icon to access the gateway's Management Console. · Click SSH or Telnet to access the gateway's command line console. To enable SDT access to the gateway console, you must configure the console server to allow port forwarded network access to itself. As of firmware v3.3, this can be done using the console server's Management Console. · Navigate to System > Firewall. Opengear User Manual. Page 147. · Click the Service Access tab. · Enable SSH Command Shell access on the Network Interface and on any Out-of-band Interfaces. With firmware versions prior to v3.3, do the following. · Navigate to Serial & Network > Network Hosts. · Click Add Host. · In the IP Address/DNS Name field enter 127.0.0.1. This is the loopback address. · Enter Loopback in the Descrip"on field. · Remove all entries under Permi$ed Services except for those that will be used in accessing the Management Console (80/h%p or 443/h%ps) or the command line (22/ssh or 23/ telnet). · click Apply. By default, Administrators have gateway access privileges. For Users to access the gateway Management Console, however, the required access privileges must be granted. · Navigate to Serial & Network > Users & Groups. · Click Add User. · Enter a Username, Descrip"on and Password. · Select 127.0.0.1 from the Accessible Host(s) pop-up menu. · click Apply. 5.4. SDT connector: telnet or SSH connect to serially-a'ached devices SDT Connector can also be used to access text consoles on devices that are a%ached to the console server's serial ports. For these connec!ons, configure the SDT Connector client so&ware with a Service that will access the target gateway serial port, and then set the gateway up as a host. · Launch SDT Connector on your PC. · Select Edit > Preferences. · Click Add. · Enter Serial Port 2 as the Service Name. · Click Add. · Select Telnet as the Client. · Enter 2002 as the TCP Port. · Click OK. · Close the Add Service window. Opengear User Manual. Page 148. · Close the SDTConnector Preferences window. · Assuming you have already set up the console server as a Gateway in your SDT Connector client (with username, password etc) select this newly added Gateway and click the Host icon to create a host. · Alterna!vely, select File > New Host. · Enter 127.0.0.1 as the Host Address. · Op!onally add details in the Descrip"ve Name and Descrip"on/Notes fields. · Click OK. · Click the Serial Port 2 icon for Telnet access to the serial console on the device a%ached to serial port #2 on the gateway. To enable SDT Connector to access to devices connected to the gateway's serial ports, configure the console server to allow port forwarded network access to itself, and enable access to the nominated serial port. · Navigate to Serial & Network > Serial Port. · Click Edit next to the selected Port. For example, click Edit next to Port 2 if the target device is a%ached to the second serial port. · Ensure the port's serial configura!on is appropriate for the a%ached device. · Set the Console Server Se#ng to Console Server Mode. · click Apply. · Navigate to Serial & Network > Network Hosts. · click Add Host. · In the IP Address/DNS Name field enter 127.0.0.1. Opengear User Manual. Page 149. This is the loopback address. · Enter Loopback in the Descrip"on field. · Remove all entries under Permi$ed Services. · Select TCP. · Enter 200n in the Port field. Note: `n' corresponds to the Serial Port selected in the step above. For Serial Port 2, for example, enter 2002. · Click Add. · Click Apply. By default, Administrators have gateway and serial port access privileges. For Users to access the gateway Management Console and the serial port, however, the required access privileges must be granted. · Navigate to Serial & Network > Users & Groups. · Click Add User. · Enter a Username, Descrip"on and Password. · Select 127.0.0.1 from the Accessible Host(s) pop-up menu. · Select Port 2 from the Accessible Port(s) pop-up menu. · click Apply. 5.5. Using SDT connector for out-of-band connec"on to the gateway SDT Connector can also be set up to connect to the console server out-of-band (OOB). OOB access uses an alternate path for connec!ng to the console server to that used for regular data traffic. OOB access is useful for when the primary link into the console server is unavailable or unreliable. Typically a console server's primary link is a broadband Internet connec!on or Internet connec!on via a LAN or VPN, and the secondary out-of-band connec!vity is provided by a dial-up or wireless modem directly a%ached to the console server. So out-of-band access enables you to access the hosts and serial devices on the network, diagnose any connec!vity issues, and restore the console server's primary link. In SDT Connector, OOB access is configured by providing the secondary IP address of the gateway, and telling SDT Connector how to start and stop the OOB connec!on. Star!ng an OOB connec!on may be achieved by ini!a!ng a dial up connec!on, or adding an alternate route to the console server. SDT Connector allows for maximum flexibility is this regard, by allowing you to provide your own scripts or commands for star!ng and stopping the OOB connec!on. To configure SDT Connector for OOB access: · Choose File > New Gateway. Opengear User Manual. Page 150. · Click the Out Of Band tab. · Enter the console server's Out of Band IP address in the Secondary Address field. The console server's Out of Band IP address is the address the console server is accessbile from when using the Out of Band access route. · Change the Port value if the console server is using a port other than the default 22 for SSH access. · Enter the command or path to a script to start the OOB connec!on in the Start Command field. · To ini!ate a pre-configured dial-up connec!on under Windows, use the following Start Command string: cmd /c start "Starting Out of Band Connection" /wait /min rasdial network_connection login password where network_connection is the name of the network connec!on as displayed in Control Panel > Network Connec"ons, login is the console server's dial-in username, and password is the console server's dial-in password. · To ini!ate a pre-configured dial-up connec!on under Linux, use the following Start Command string: pon network_connection where network_connection is the name of the connec!on. · Enter the command or path to a script to stop the OOB connec!on in the Stop Command field. · To stop a pre-configured dial-up connec!on under Windows, use the following Stop Command string: cmd /c start "Stopping Out of Band Connection" /wait /min rasdial network_connection /disconnect where network_connection is the name of the network connec!on as displayed in Control Panel > Network Connec"ons. · To stop a pre-configured dial-up connec!on under Linux, use the following Stop Command string: poff network_connection To make the OOB connec!on using SDT Connector: · Select the console server to connect to. · Click the Out Of Band bu%on. The status bar changes color to indicate this console server is being accessed using the OOB link rather than the primary link. When you connect to a service on a host behind the console server, or to the console server itself, SDT Connector will ini!ate the OOB connec!on using the provided Start Command. The OOB connec!on isn't stopped (using the provided Stop Command) un!l Out Of Band under Opengear User Manual. Page 151. Gateway Ac"ons is clicked off, at which point the status bar will return to its normal color. 5.6. Impor"ng and expor"ng preferences To enable the distribu!on of pre-configured client config files, SDT Connector has an Import and Export facility: To save a configura!on .xml file for backup or for impor!ng into other SDT Connector clients): · select File > Export Preferences. · select the loca!on to save the configura!on file. To import a configura!on: · select File > Import Preferences. · select the .xml configura!on file to be installed. 5.7. SDT connector public key authen"ca"on SDT Connector can authen!cate against an SSH gateway using your SSH key pair rather than requiring you to enter your password. This is known as public key authen!ca!on. To use public key authen!ca!on with SDT Connector, first you must add the public part of your SSH key pair to your SSH gateway. · Ensure the SSH gateway allows public key authen!ca!on. This is typically the default behavior. · If you do not already have a public/private key pair for your client PC (the one running SDT Connector) generate them now using ssh-keygen, PuTTYgen or a similar tool. See chapter 14.6 for details on genera!ng and installing public/private key pairs. Note: You can use RSA or DSA. In this case, however, leave the passphrase field blank. · Upload the public part of your SSH key pair (typically named id_rsa.pub or id_dsa.pub) to the SSH gateway, or otherwise add to .ssh/authorized keys in your home directory on the SSH gateway. · Add the private SSH key (typically named id_rsa or id_dsa) to SDT Connector. · Click Edit > Preferences. Opengear User Manual. Page 152. · Select Private Keys. · click Add. · navigate to and select the private key file. · Click OK. You do not have to add the public SSH key: it is calculated using the private key. SDT Connector will now use public key authen!ca!on when connec!ng through the SSH console server. Note: you may have to restart SDT Connector to shut down exis#ng SSH tunnels established using password authen#ca#on. If you have a host behind the console server that you connect to by clicking the SSH bu%on in SDT Connector you may wish to configure access to it for public key authen!ca!on as well. This configura!on is en!rely independent of SDT Connector and the SSH console server. You must configure the SSH client that SDT Connector launches (for example Pu%y or OpenSSH) and the host's SSH server for public key authen!ca!on. Essen!ally what you are using is SSH over SSH, and the two SSH connec!ons are en!rely separate. 5.8. Se&ng up SDT for remote desktop access Microso&'s Remote Desktop Protocol (RDP) enables the system manager to: · securely access and manages remote Windows computers · to reconfigure applica!ons and user profiles on Windows computers · to upgrade a Windows server opera!ng system. · reboot the machine and more. Opengear's Secure Tunneling uses SSH tunneling, so this RDP traffic is securely transferred through an authen!cated and encrypted tunnel. SDT with RDP also allows remote Users to connect to Windows XP and later computers and to Windows 2000 Terminal Servers; and to have access to all of the applica!ons, files, and network resources (with full graphical interface just as though they were in front of the computer screen at work). To set up a secure Remote Desktop connec!on you must enable Remote Desktop on the target Windows computer that is to be accessed and configure the RPD client so&ware on the client PC. 5.8.1. Enable Remote Desktop on the target Windows computer to be accessed Note: Windows XP Professional and Windows Vista only support one Remote Desktop session and it connects directly to the Windows root console. Windows Server 2003 supports three sessions: the console session and two other general sessions. Windows Server 2008 supports mul#ple sessions. To enable Remote Desktop on the Windows computer being accessed: Opengear User Manual. Page 153. · navigate to Start Menu > Control Panel. · double-click the System icon. · click the Remote tab. · check the Allow users to connect remotely to this computer checkbox. · click the Select Remote Users... bu%on. The Remote Desktop Users window opens. · Click the Add... bu%on to add users to the list of those allowed to remotely access the system using the RDP protocol. · Click OK to close the Remote Desktop Users window. · Click OK to close the System Proper"es window. Windows generates the available user list from local accounts on the target Windows computer. If you need to setup new users to then add them to the Remote Desktop Users list: · navigate to Start Menu > Control Panel. · double-click the User Accounts icon. · create new users as required. Note: when a remote user connects to the accessed computer via the root console, Remote Desktop automa#cally locks that computer (so no other user can access the applica#ons and files). When you come back to your computer, you can unlock it by typing CTRL+ALT+DEL. 5.8.2. Configure the Remote Desktop connec"on client Opengear User Manual. Page 154. Once the Client computer is securely connected to the console server (either locally, or remotely through an enterprise VPN, a secure SSH internet tunnel or a dial-in SSH tunnel) you can establish the Remote Desktop connec!on from the Client. To do this enable the Remote Desktop Connec!on on the remote client PC then point it to the SDT Secure Tunnel port in the console server. On a Windows client · Navigate to Start Menu > Programs > Accessories > Communica"ons. · Click Remote Desktop Connec"on. · Enter the appropriate IP address and port number in Computer. Where there is a local connec!on or enterprise VPN connec!on, enter the IP Address of the console server, and the port number of the SDT Secure Tunnel for the console server serial port that is a%ached to the Windows computer to be controlled. For example, if the Windows computer is connected to serial Port 3 on a console server located at 192.168.0.50 enter 192.168.0.50:7303. Where there is an SSH tunnel over a dial up PPP connec!on or over a public internet connec!on or private network connec!on, enter localhost as the IP address (that is, 127.0.0.1). For Port Number, enter the source port you created when se$ng up SSH tunneling/port forwarding (see chapter 5.1). · Click Op"on. · Specify an appropriate color depth in the Display sec!on. For example, for a connec!on running over a modem, don't set the color depth to greater than 256 colors (8-bit). · In Local Resources specify the peripherals and ports on the remote Windows computer that are available to be controlled (for example, a directly connected printer or the serial port on the Windows PC). · Click Connect. On a Linux or UNIX client · Launch the open source rdesktop client from a shell. For example: Opengear User Manual. Page 155. rdesktop -u windows-user-id -p windows-password -g 1200x950 mswindows-terminal-server-host-name rdesktop op"on -a -r -g -p descrip"on Color depth. Valid values are 8, 16, and 24. Device redirec!on. Redirects remote machine sound to the local device. Display geometry. Either widthxheight in pixels, or % of local screen. Sets rdesktop to receive a password prompt form the remote machine. You can use GUI front end tools such as the GNOME Terminal Services Client tsclient to configure and launch the rdesktop client. Using tsclient also enables you to store mul!ple configura!ons of rdesktop for connec!on to many servers. On an OS X client · Download Microso&'s free Remote Desktop Connec!on client from h%ps://microso&.com/ en-us/download/details.aspx?id=18140. Note: Microso( Remote Desktop Connec#on Client for OS X is not supported for use with OS X v10.7 (Lion) or later. 5.9. SDT SSH tunnel for VNC Alternately, with SDT and Virtual Network Compu!ng (VNC), Users and Administrators can securely access and control computers running Windows, Linux, macOS, Solaris and UNIX. There is a range of VNC so&ware available (UltraVNC, RealVNC, TightVNC), both open source and commercial. To set up a secure VNC connec!on you must · install and configure the VNC Server so&ware on the computer to be accessed. · install and configure the VNC Viewer so&ware on the Viewer PC. 5.9.1. Install & configure the VNC server on the computer to be accessed Virtual Network Compu!ng (VNC) so&ware enables users to remotely access computers running Linux, macOS, Solaris, UNIX, all versions of Windows and most other opera!ng systems. VNC Servers RealVNC Connect, h%ps://realvnc.com/, is a mul!-pla*orm VNC server that runs on Windows, macOS, Linux, Solaris, HP-UX, AIX, and Raspberry Pi. RealVNC also offers a VNC client, RealVNC Viewer, which runs on these pla*orms as well as iOS, Android, and Chrome. Opengear User Manual. Page 156. TightVNC, h%ps://!ghtvnc.com/, is a dual-licensed (GPL and commercial) VNC server for Windows. TightVNC also offer a Java-based VNC viewer. It works on any system with Java SE version 1.6 or later installed. UltraVNC, h%p://uvnc.com/, is a free VN server and viewer for Windows. Most Linux distribu!ons now ship with VNC servers and viewers pre-installed. If a running Linux instance does not have VNC so&ware installed, it will almost certainly be available for immediate download and install via the distro's secure so&ware repository. For example, to turn the VNC server on in Centos 7: · Navigate to Applica"ons > System Tools > Se!ngs. · Click Sharing. · Click Screen Sharing. · Click the On-Off control to start the VNC server. Immediately below the Screen Sharing !tle bar is the vnc-protocol URL the computer is accessible via. Opengear User Manual. Page 157. · Click the Require a password radio bu%on. · Create and Enter the Password remote clients must enter to view the Centos screen. · Click the Close box in the top right-hand corner of the Screen Sharing window. · Click the Close box in the top right-hand corner of the Sharing window. macOS also ships with a VNC server. To turn this server on and make a macOS computer available to VNC clients: · Choose Apple Menu > System Preferences. · Click the Sharing icon (or choose View > Sharing). · Check the Screen Sharing checkbox. The built-in VNC server is now running. Immediately below the text Screen Sharing: On is the vnc-protocol URL the computer is accessible via. · Click the Computer Se!ngs... bu%on. · Check the VNC viewers may control screen with password checkbox. · Create and enter the password said VNC viewer applica!ons will need to supply. · Click OK. 5.9.2. Install, configure & connect the VNC viewer VNC is pla*orm-independent so a VNC viewer on any opera!ng system can connect to a VNC server on any other opera!ng system. There are viewers and servers from a wide selec!on of sources (for example, UltraVNC TightVNC or RealVNC) for most opera!ng systems. There are also a wealth of Java viewers available so that any desktop can be viewed with any Java-capable browser. h%p:// en.wikipedia.org/wiki/VNC lists many of the VNC viewers sources. To make VNC faster, when you set up the VNC viewer: · if you have a fast enough CPU, set encoding to ZRLE. · decrease the color level (for example, 64-bit). · disable the background transmission on the server, or use a plain wallpaper. See h%p://doc.uvnc.com/ for detailed configura!on instruc!ons. To establish a VNC connec!on: · enter the VNC server IP address and port. When the VNC viewer is connected to the console server via an SSH tunnel, whether over the public Internet, a dial-in connec!on, or a private network connec!on, enter localhost or 127.0.0.1 as the VNC server's IP address. The port number is the number entered when se$ng up SSH tunneling/port forwarding in sec!on 5.2.6. For example: 1234. Opengear User Manual. Page 158. When the VNC viewer is connected directly to the console server (that is locally or remotely through a VPN or dial in connec!on) and the VNC server is serially connected to the console server, enter the IP address of the console server unit with the TCP port that the SDT tunnel will use. The TCP port will be 7900 plus the physical serial port number (that is 7901 to 7948). All traffic directed to port 79xx on the console server is tunneled thru to port 5900 on the PPP connec!on on serial Port xx. For example, for a Windows computer using UltraVNC as the viewer connec!ng to a VNC server which is a%ached to Port 1 on a console server located 192.168.0.1: · establish the VNC connec!on by ac!va!ng the VNC viewer and entering the Password. Opengear User Manual. Page 159. For background reading on Remote Desktop and VNC access we recommend the following: The Microso& Remote Desktop How-To: h%p://www.microso&.com/windowsxp/using/ mobility/getstarted/remoteintro.mspx. The Illustrated Network Remote Desktop help page: h%p://theillustratednetwork.mvps.org/ RemoteDesktop/RemoteDesktopSetupandTroubleshoo!ng.html. What is Remote Desktop in Windows XP and Windows Server 2003? by Daniel Petri: h%p:// www.petri.co.il/what's_remote_desktop.htm. Frequently Asked Ques!ons about Remote Desktop: h%p://www.microso&.com/windowsxp/ using/mobility/rdfaq.mspx. Secure remote access of a home network using SSH, Remote Desktop and VNC for the home user: h%p://theillustratednetwork.mvps.org/RemoteDesktop/SSH-RDP-VNC/ RemoteDesktopVNCandSSH.html. Taking your desktop virtual with VNC: Red Hat magazine / and /. Wikipedia's general background ar!cle on VNC: h%p://en.wikipedia.org/wiki/VNC. 5.10. Using SDT to IP connect to hosts that are serially-a'ached to the gateway Network (IP) protocols like RDP, VNC and HTTP can also be used for connec!ng to host devices that are serially connected through their COM port to the console server. To do this you must: · establish a PPP connec!on between the host and the gateway. See chapter 5.10.1. · set up Secure Tunneling Ports on the console server. See chapter 5.10.2. · configure SDT Connector to use the appropriate network protocol to access IP consoles on the host devices that are a%ached to the console server serial ports. See chapter 5.10.3. 5.10.1. Establish a PPP connec"on between the host COM port & console server · (This step is only necessary for serially-connected computers.) Physically connect the COM port on the host computer that is to be accessed, to the serial port on the console server. · On computers running Linux, UNIX, Solaris and other Unix-like opera!ng systems, establishy a PPP connec!on over the serial port. The online tutorial at h%p://yolinux.com/TUTORIALS/LinuxTutorialPPP.html presents a selec!on of methods for establishing a PPP connec!on using a computer running Linux. · On computers running Windows, follow the procedure below to set up an advanced network connec!on between the Windows computer's COM port and the console server. Windows allows for the crea!on of a simple dial-in service which can be used for a Remote Desktop or VNX or HTTP/X connec!on to the console server. · Navigate to Start Menu > Control Panel. · Double-click the Network Connec"ons icon. · Click the New Connec"on Wizard. Opengear User Manual. Page 160. · Select the Set up an advanced connec"on radio bu%on. · Select Accept Incoming Connec"ons in the Advanced Connec"on Op"ons window. · click Next. · Select COM1 as the Connec"on Device (that is, the COM port on the computer that is connected to the console server's serial port). · Set the COM port to its maximum baud rate. · Click Next. · Select Do not allow virtual private connec"ons in the Incoming VPN Connec"on Op"ons window. · Click Next. · Select which users will be allowed to use this connec!on. This should be the same users given Remote Desktop access privileges in the earlier step. · Click Next. · Select TCP/IP in the Network Connec"ons window. · Click Proper"es. · Select Specify TCP/IP addresses in the Incoming TCP/IP Proper"es window. · Enter IP addresses in the From and To fields. Choose any TCP/IP addresses so long as they are addresses which are not used anywhere else on your network. The From address will be assigned to the computer running Windows. The To address will be used by the console server. For simplicity use the IP address shown in the illustra!on above: Opengear User Manual. Page 161. From To 169.134.13.1 169.134.13.2 Alterna!vely, set the advanced connec!on and access on the computer running Windows to use the console server defaults: From 10.233.111.254 Allow calling computer to specify its own IP address checked. · Click OK. Another op!on is to use the console server's default username and password to setup the Remote Desktop user and give this user permission to use the advancd connec!uon to access the computer running Windows. · The console server's default Username is portXX where XX is the serial port number on the console server. · The console server's default Password is portXX where XX is the serial port number on the console server. For example, for an RDP connec!on to serial port 2 on the console server, setup a Windows user named port02 with appropriate permissions. When the PPP connec!on has been set up, a network icon appears in the Windows task bar. The above notes describe se$ng up an incoming connec!on for Windows XP. The steps are similar for later versions of Windows although the set up screens present slightly differently. If presented with an Incoming Connec"ons Proper"es window such as above, check the Always allow directly connected devices such as palmtop computers to connect without providing a password check box. Also the op!on to Set up an advanced connec"on is not available in Windows 2003 if RRAS is configured. If RRAS has been configured enable the null modem connec!on for the dial-in configura!on. Opengear User Manual. Page 162. 5.10.2. Set up SDT serial ports on console server To set up RDP (and VNC) forwarding on the console server Serial Port that is connected to the Windows computer COM port: · Navigate to Serial & Network > Serial Port. · click Edit for the par!cular Serial Port connected to the Windows computer's COM port. · Select SDT Mode in the SDT Se!ngs sec!on. This will enable port forwarding and SSH tunneling. Note: Enabling SDT overrides all other configura#on protocols on this port. · enter a Username and User Password. If you leave the Username and User Password fields blank, they both default to portXX where XX is the serial port number. For example, the default username and password for Secure RDP over Port 2 is port02. · Set the console server's serial port Common Se#ngs (Baud Rate and Flow Control) to the same values as were set up on the Windows computer' COM port. · click Apply. RDP and VNC forwarding over serial ports is enabled on a per-Port basis. You can add Users who can have access to these ports (or reconfigure User profiles) by naviga!ng to Serial & Network > User & Groups as documented in chapter 3. 5.10.3. Set up SDT connector to SSH port forward over the console server serial port In the SDT Connector so&ware running on your remote computer, specify the gateway IP address of your console server and specify a username and password for a user you have setup on the console server that has access to the desired port. Next add a New SDT Host. In the Host address put portxx where xx is the port you are connec!ng to. For example, for port 3 enter a Host Address of port03 and then check the RDP Service check box. 5.11. SSH tunnelling using other SSH clients (for example, PuTTY) SDT Connector, which is supplied with console servers is Opengear's recommended SSH client. Opengear User Manual. Page 163. There are, however, other SSH client programs that can provide secure SSH connec!ons to console servers and connected devices, including: ssh client PuTTY SSHTerm Tec!a SSH Reflec!on for Secure IT source h%p://pu%y.org/ h%p://sourceforge.net/projects/sshtools h%ps://ssh.com/products/tec!a-ssh/ h%ps://www.microfocus.com/products/ reflec!on-secure-it descrip"on An open-source SSH implementa!on for Windows. A Java-based open-source SSH communia!ons suite. A commercial SSH client and server. A commercial SSH client and server. This sec!on documents the use of the PuTTY client to establish an SSH-tunneled connec!on to a network-connected device. · Launch PuTTY. The PuTTY Configura"on window opens. · Click Session in the Category sec!on. · Enter the IP address of the console server to connect to in the Host Name or IP address field. For dial-in connec!ons, this IP address will be the Local Address that you assigned to the console server when you set it up as the Dial-In PPP Server. For Internet or local/VPN connec!ons this will be the public IP address of the console server. · Leave the port number as 22 (unless you've configured the console server to run SSH on a port other than the default value of 22). · Click the SSH radio bu%on under Connec"on type. · Click Tunnels in the Category sec!on (in the disclosure tree this is in Connec"on > SSH). · Enter any high, unused port number (for example: 55555) in the Source port field under Add new forwarded port. · Enter the Des"na"on IP address and port. If your des!na!on device is network connected to the console server and you are connec!ng using RDP, set the Des!na!on as managed-device-ipaddress-or-hostname:3389 For example, if, when se$ng up the Managed Device as Network Host on the console server its IP address was sets to 192.168.253.1 or its hostname was set to accounts.myco.intranet.com Opengear User Manual. Page 164. then set the Des"na"on to 192.168.523.1:3389 or accounts.myco.intranet.com:3389 Note: only devices which have been configured as networked Hosts can be accessed using SSH tunneling (except by the root user who can tunnel to any IP address the console server can route to). If your des!na!on computer is serially-connected to the console server, set the Des"na"on as port-label:3389 For example, if the Label you specified on the serial port on the console server is win2k3, then specify the remote host as win2k3:3389 Alterna!vely, set the Des"na"on as portXX:3389 where XX is the SDT-enabled serial port number. For exmaple, if port 4 on the console server carries the RDP traffic then set the Des"na"on to port04:3389 · Select the Local radio bu%on. · Click Add. · Click Open. A shell prompt window will open promp!ng you to login as: · Enter a username and press Return. The shell will return a password prompt. · Enter the user's password. and press Return. If you are connec!ng as a user in the users group you can only SSH tunnel to hosts and serial ports where you have specific access permissions. If you are connec!ng as an administrator (that is, a user in the admin group) then you can connect to any configured host or serial port which has SDT enabled. To set up the secure SSH tunnel for a HTTP browser connec!on to the managed device, specify port 80 (rather than port 3389, used for RDP) in the Des"na"on IP field. To set up the secure SSH tunnel from the Client PC to the console server for VNC, configure the VNC port redirec!on by specifying port 5900 in the Des"na"on IP field. Opengear User Manual. Page 165. 5.12. VNC security How secure is VNC? VNC access generally allows access to your whole computer, so security is very important. VNC uses a random challenge-response system to provide the basic authen!ca!on that allows you to connect to a VNC server. This is reasonably secure and the password is not sent over the network. However, once connected, all subsequent VNC traffic is unencrypted. So a malicious user could snoop your VNC session. Also there are VNC scanning programs available, which will scan a subnet looking for PCs which are listening on one of the ports which VNC uses. Tunneling VNC over a SSH connec!on ensures all traffic is strongly encrypted. Also no VNC port is ever open to the internet, so anyone scanning for open VNC ports will not be able to find your computers. When tunneling VNC over a SSH connec!on, the only port which you are opening on your console server is the SDT port (port 22). It may be prudent to tunnel VNC through SSH even when the Viewer PC and the console server are both on the same local network. Opengear User Manual. Page 166. 6.Alerts, auto-response & logging This chapter describes the automated response, alert genera!on and logging features of the console server. The Auto-Response facility extends on the basic Alert facility available in earlier (pre V3.5) firmware revisions. With Auto-Response the console server monitors selected serial ports, logins, the power status and environmental monitors and probes for Check Condi!on triggers. The console server will then ini!ate a sequence of ac!ons in response to these triggers. To configure Auto-Response you: · set the general parameters. · select and configure the Check Condi"ons (the condi!ons that trigger the response). · specify the Trigger Ac"ons (the ac!on sequence ini!ated in event of the trigger condi!on). · specify the Resolve Ac"ons (the ac!ons performed when trigger condi!ons are resolved). Also all console server models can maintain log records of all access and communica!ons with the console server and with the a%ached serial devices. A log of all system ac!vity is also maintained as is a history of the status of any a%ached environmental monitors. Some models can also log access and communica!ons with network a%ached hosts and maintain a history of the UPS and PDU power status. If port logs are to be maintained on a remote server, then the access path to this loca!on need to be configured Then you need to ac!vate and set the desired levels of logging for each serial and network port and for power and environment UPS (see chapter 7). Opengear User Manual. Page 167. 6.1. Configure auto-response With the Auto-Response facility, a sequence of Trigger Ac!ons is ini!ated in the event of a specified trigger condi!on (the Check Condi"on). Subsequent Resolve Ac"ons can also be performed when the trigger condi!on has been resolved. First set the general parameters that will be applied to all Auto-Responses. · Navigate to Alerts & Logging > Auto-Response. · Check the Log Events checkbox in the Global Auto-Response Se!ngs sec!on. This enables logging of all Auto-Response ac!vi!es. · Set the Delay a&er boot !me (in seconds) to establish the delay between a console server boo!ng and the same console server processing events. To configure a new Auto-Response: · Select New Auto-Response in the Configured Auto-Response field. A new Auto-Response Se!ngs page presents. · Enter a unique Name for the new Auto-Response. · Specify the Reset Timeout for the !me in seconds a&er resolu!on to delay before this Auto-Response can be triggered again. Opengear User Manual. Page 168. · Check Repeat Trigger Ac"ons to repeat trigger ac!ons un!l the check is resolved. · Enter any required delay !me before repea!ng trigger ac!ons in Repeat Trigger Ac"on Delay. This delay starts a&er the last ac!on is queued. · Check Disable Auto-Response at specific "mes and you will be able to periodically disable auto-Responses between specified !mes of day. 6.2. Check condi"ons To configure the condi!on that will trigger the Auto-Response: · Click on the Check Condi"on type (for example, Environmental, UPS Status or ICMP ping) to be configured as the trigger for this Auto-Response in the Auto-Response Se!ngs menu. 6.2.1. Environmental To configure Humidity or Temperature levels as the trigger event: Opengear User Manual. Page 169. · Click on Environmental as the Check Condi"on. · In the Environmental Check menu, select the specific environmental sensor to be checked for the trigger · Specify the Trigger value (in °C or °F for temperature and % for humidity) that the check measurement must exceed or drop below to trigger the AutoResponse. · Select Comparison type as being Above Trigger Value or Below Trigger Value to trigger · Specify any Hysteresis factor that is to be applied to environmental measurements. For example, if an Auto-Response was set up with a trigger event of a temp reading above 49°C with a Hysteresis of 4, then the trigger condi!on would not be seen as having been resolved !ll the temperature reading was below 45°C. · Check Save Auto-Response. Note: before configuring Environmental Checks as the trigger in Auto-Response you will need first to configure the Temperature sensores, the Humidity sensors or both on your ACM5000 or a"ached EMD. 6.2.2. Alarms & digital inputs To set the status of any a%ached Smoke or Water sensors or digital inputs as the trigger event: · Click on Alarms/Digital Inputs as the Check Condi"on. · In the Alarms/Digital Inputs Check menu, select the specific Alarm/Digital IO Pin that will trigger the Auto-Response. · Select Trigger on Change to trigger when alarm signal changes, or select to trigger when the alarm signal state changes to either a Trigger Value of Open (0) or Closed (1). · Check Save Auto-Response. Note: before configuring Alarms/Digital Inputs checks in Auto-Response you first must configure the sensor/DIO that is to be a"ached to your EMD or ACM5000. 6.2.3. UPS & power supply To use the proper!es of any a%ached UPS as the trigger event: · select UPS/Power Supply as the Check Condi"on. · Select the UPS Power Device Property (Input Voltage, Ba%ery Charge %, Load %, Input Frequency Hz or Temperature in °C) to be checked for the trigger. · specify the Trigger value that the check measurement must exceed or drop below to trigger the AutoResponse. · select the Comparison type as being Above Trigger Value or Below Trigger Value to trigger. · specify any Hysteresis factor to be applied to environmental measurements. For example, if an Auto-Response is set up with a trigger event of a ba%ery charge below 20% with a Hysteresis of 5 then the trigger condi!on will not be set to resolved un!l the Opengear User Manual. Page 170. ba%ery charge is above 25%. · Check Save Auto-Response. Note: before configuring UPS checks in Auto-Response you first must configure the a"ached UPS 6.2.4. UPS status To use the alert state of any a%ached UPS as the Auto-Response trigger event: · click on UPS Status as the Check Condi"on. · select the reported UPS State to trigger the Auto-Response (either On Ba%ery or Low Ba%ery). The Auto-Response will resolve when the UPS state returns to the Online state. · select which connected UPS Device to monitor. · Click Save Auto-Response. Note: before configuring UPS state checks in Auto-Response the a"ached UPS must be configured. 6.2.5. Serial log-in, signal or pa'ern To monitor serial ports and check for login/logout or pa%ern matches for Auto-Response triggers events: · click on Serial Login/Logout as the Check Condi"on. · in the Serial Login/Logout Check menu select Trigger on Login (to trigger when any user logs into the serial port) or Trigger on Logout. · specify Serial Port to perform check on. · click on Serial Signal as the Check Condi"on. Opengear User Manual. Page 171. The above two op!ons can be set individually or together. · in the Serial Signal Check menu select the Signal (CTS, DCD, DSR) to trigger the condi!on (either on serial signal change, or check level). · specify Serial Port to perform check on. · click on Serial Pa$ern as the Check Condi"on. The above two op!ons can be set individually or together. · in the Serial Pa$ern Check menu select the PCRE pa%ern to trigger on and the serial line (TX or RX) and Serial Port to pa%ern check on. Note: With Serial Pa%ern checks you can nominate to Disconnect Immediately all users from the serial port being monitored in the event of a successful pa"ern match. Note: for devices with an inbuilt cellular modem with GPS enabled, the GPS will be displayed as an addi#onal port and it can be monitored for trigger events. For example, with an ACM5504-5-G-I with 4 serial ports, the GPS will be shown as Port 5. · Click Save Auto-Response. Note: before configuring serial port checks in Auto-Response the affected serial port must be configured in Console server mode. Also, most serial port checks are not resolvable so resolve ac#ons will not run. 6.2.6. USB console status Note: USB port labels in the Web interface match the USB port labels printed on a console server with two excep#ons. Some console servers include discrete pairs of USB ports which do not have printed labels. In this case, the Web interface denotes them as either Upper or Lower. That is, the Web interface lists them by their physical rela#onship to each other. Also, some console servers ship with an array of four USB ports. A limited number of these console Opengear User Manual. Page 172. servers have labels A D printed by these ports even though the Web interface will denote them as USB ports 1 4. To monitor USB ports: · Select USB Console Status as the Check Condi"on. · Check the Trigger on Connect checkbox, the Trigger on Disconnect checkbox, or both checkboxes to set which ac!ons trigger the Auto-Response. · Check each USB port to be monitored (or click the Select/Unselect all Ports checkbox to select or deselect all USB ports). · Click the Save Auto-Response bu%on. · Select an op!on from the Add Trigger Ac"on list. · Enter a unique Ac"on Name for the trigger ac!on being created. · Set an Ac"on Delay Time. By default, this is 0 seconds. · Enter the specific details of the selected ac!on. For example, the Send Email ac!on requires a Recipient Email Address and allows for a Subject and Email Text. · Click the Save New Ac"on bu%on. Note: USB console status checks are not resolvable. Trigger ac#ons run but Resolve ac#ons do not. 6.2.7. ICMP ping To use a ping result as the Auto-Response trigger event: · select ICMP Ping as the Check Condi"on. · specify which Address to Ping (that is, the IP address or DNS name to send ICMP pings to). · specify which Interface to send ICMP pings from (for example, the Management LAN or Wireless network). · set the Check Frequency. This is the !me in seconds between checks. · set the Number of ICMP Ping packets to send. · check Save Auto-Response. 6.2.8. Cellular data This check monitors the aggregate data traffic inbound and outbound through the cellular modem as an Auto-Response trigger event. · Select Cellular Data as the Check Condi"on. Note: before configuring cellular data checks in Auto-Response, the internal cellular modem must be configured and detected by the console server. Opengear User Manual. Page 173. 6.2.9. Custom check This check allows users to run a nominated custom script with nominated arguments whose return value is used as an Auto-Response trigger event: · Click on Custom Check as the Check Condi"on. · Create an executable trigger check script file. For example /etc/config/test.sh #!/bin/sh logger "A test script" logger Argument1 = $1 logger Argument2 = $2 logger Argument3 = $3 logger Argument4 = $4 if [ -f /etc/config/customscript.0 ]; then rm /etc/config/customscript.0 exit 7 fi touch /etc/config/customscript.0 exit 1 Note: refer to the Opengear FAQ for a sample web page html check and other script file templates. · Enter the Script Executable file name. Opengear User Manual. Page 174. For example /etc/config/test.sh. · Set the Check Frequency. This is the !me, in seconds, between re-running the script. · Set the Script Timeout. This is the maximum run-!me for the script. · Specify the Successful Return Code. An Auto-Response is triggered if the return code from the script is not this value. · Enter Arguments that are to be passed to the script. For example, with a web page html check script, these Arguments might specify the web page address/DNS and user logins. Check Save Auto-Response. 6.2.10. SMS command An incoming SMS command from a nominated caller can trigger an Auto-Response: · Select SMS Command as the Check Condi"on. · Set the Phone number. For mul!ple SMS sources comma-separate the numbers. Note: enter the phone number in interna#onal format without the plus-sign (+) prefix. · Set the Incoming Message Pa$ern to match to create trigger event. This pa%ern is a PCRE regular expression. Note: the SMS command trigger condi#on can only be set if an internal cellular modem detected. · Click Save Auto-Response. 6.2.11. Log-in & log-out check To configure Web Log In/Out as the trigger event: · select Web UI Authen"ca"on as the Check Condi"on. · check Trigger on Login or Trigger on Logout to trigger if a user logs into or out of the Web UI. · Check Trigger on Authen"ca"on Error to trigger when Web UI user authen!ca!on fails. Opengear User Manual. Page 175. Note: this check is not resolvable. Resolve ac#ons will not, as a consequence, run. · Click Save Auto-Response. 6.2.12. Network interface event You may wish to configure a change in the network status as the trigger event (e.g. to send an alert or restart a VPN tunnel connec!on): · select Network Interface as the Check Condi"on. · select the Interface to monitor. · check the interface Event to trigger on. Note: this check is not resolvable. Resolve ac#ons will not, as a consequence, run. · Click Save Auto-Response. 6.2.13. Routed data usage check This check monitors the specified input interface for data usage that is being routed through the Opengear and out another interface such as the Internal Cellular Modem. It is par!cularly useful in IP Passthrough mode, to detect when the downstream router has failed over and is now rou!ng via the Opengear's modem as a backup connec!on. This check may be configured with these parameters: · the Opengear's incoming Interface to monitor. Opengear User Manual. Page 176. · an op!onal Source MAC address or source IP Address, to monitor traffic from a specific host (for example, the downstream router). · a Data Limit threshold and specified Time Period. The Auto-Response will trigger when the limit is hit in the specified !me. The Auto-Response will resolve if no matching data is routed for the Resolve Period. 6.3. Trigger ac"ons To configure the sequence of ac!ons that is to be taken in the event of the trigger condi!on: · for a nominated Auto-Response with a defined Check Condi"on, select an Add Trigger Ac"on (for example, Send Email or Run Custom Script). This selects the ac!on type to be taken. · configure the selected ac!on (as detailed in the sec!ons following). Each ac!on is configured with a nominated Ac"on Delay Time which specifies how long (in seconds) a&er the Auto-Response trigger event to wait before performing the ac!on. Note: you can add follow-on ac#ons to create a sequence of ac#ons that will be taken in the event of the one trigger condi#on. To edit or delete an exis!ng ac!on: · click the Modify or Delete icon in the Scheduled Trigger Ac"on table. A message text can be sent with Email, SMS and Nagios ac!ons. This configurable message can include selected values: value descrip"on $AR_TRIGGER_VAL The trigger value for the check. For example the UPS Status trigger value can be either onba$ or ba$low. $AR_VAL The value returned by the check. For example the ups status value can be online, onba$, or ba$low. $AR_CHECK_DEV $TIMESTAMP The name of the device being checked. For example, for Alarm, the alarm name. The current !mestamp. Opengear User Manual. Page 177. $HOSTNAME The hostname of the console server. The default message text is: $TIMESTAMP: This ac!on was run -- Check details: value $AR_VAL vs trigger value $AR_TRIGGER_VAL. 6.3.1. Send e-mail · Select Send Email as the Add Trigger Ac"on. · Enter a unique Ac"on Name. · Set the Ac"on Delay Time. · Specify the Recipient Email Address to send this email to For mul!ple recipients enter comma-separated addresses. · Enter a Subject for the email. · Edit the Email Text message to send. · click Save New Ac"on. Note: an SMS alert can also be sent via an SMTP (email) gateway. You will need to specify the Recipient Email Address in the format specified by the gateway provider. For example, for TMobile it is phonenumber@tmomail.net. 6.3.2. Send SMS · Select Send SMS as the Add Trigger Ac"on. · Enter a unique Ac"on Name. · Set the Ac"on Delay Time. · Specify the Phone number that the SMS will be sent to. This must be in interna!onal format bit without the leading plus (+) sign. · Edit the Message Text to send · click Save New Ac"on. Note: the SMS alert can be sent if there is an internal cellular modem a"ached. Alterna#vely an SMS alert can also be sent via a SMTP SMS gateway as documented in chapter 6.5.2. 6.3.3. Perform RPC ac"on · Select Perform RPC Acr"on as the Add Trigger Ac"on. · Enter a unique Ac"on Name. · Set the Ac"on Delay Time. · Select a power Outlet. · Specify the Ac"on (Power On, Power Off, or Cycle) to be performed. Opengear User Manual. Page 178. · click Save New Ac"on. 6.3.4. Run custom script · Select Run Custom Script as the Add Trigger Ac"on. · Enter a unique Ac"on Name. · Set the Ac"on Delay Time. · Create a script file to execute when this ac!on is triggered. · Enter the Script Executable's file name. For example /etc/config/action.sh. · Set the Script Timeout. This is the maximum run-!me for the script. Set this at 0 for unlimited !me. · Enter any Arguments that are to be passed to the script. · click Save New Ac"on. 6.3.5. Send SNMP trap · Select Send SNMP Trap as the Add Trigger Ac"on. · Enter a unique Ac"on Name. · Set the Ac"on Delay Time. Note: the SNMP Trap ac#ons are valid for Serial, Environmental, UPS and Cellular data triggers. · click Save New Ac"on. 6.3.6. Send Nagios event · Select Send Nagios Event as the Add Trigger Ac"on. · Enter a unique Ac"on Name. · Set the Ac"on Delay Time. · Edit the Nagios Event Message text to display on the Nagios status screen for the service. · Specify the Nagios Event State (OK, Warning, Cri"cal, or Unknown) to return to Nagios for this service. · click Save New Ac"on. Note: to no#fy the central Nagios server of Alerts, NSCA must be enabled under System > Nagios and Nagios must be enabled for each applicable host or port. 6.3.7. Perform interface ac"on · Select Perform Interface Ac"on as the Add Trigger Ac"on. Opengear User Manual. Page 179. · Enter a unique Ac"on Name. · Set the Ac"on Delay Time. · Select the Interface (Modem or VPN Service). · Select the Ac"on (Start Interface or Stop Interface) to be taken. For example, you may wish to start an IPsec VPN service in response to an incoming SMS message, or set up an OpenVPN tunnel whenever your console server fails over to use the cellular connec!on. · click Save New Ac"on. Note: If any IPsec service or OpenVPN tunnel is to be controlled by the Network Interface Event Ac"on, the Control by Auto-Response checkbox must be checked when configuring that service. Also, if selected, the default state for the VPN tunnel or service will be Down. 6.4. Resolve ac"ons Ac!ons can also be scheduled to be taken a trigger condi!on has been resolved. · For a nominated Auto-Response with a defined trigger Check Condi!on, click Add Resolve Ac"on (for example, Send Email or Run Custom Script) to select the ac!on type to be taken. Note: Resolve Ac"ons are configured the same way as Trigger Ac"ons except the designated Resolve Ac"ons are all executed on resolu#on of the trigger condi#on and there are no Ac"on Delay Times to set. 6.5. Configure SMTP, SMS, SNMP & Nagios service for alert no"fica"ons The Auto-Response facility enables remote alerts to be sent as Trigger and Resolve Ac!ons. Before such alert no!fica!ons can be sent, you must configure the nominated alert service. 6.5.1. Send e-mail alerts The console server uses SMTP (Simple Mail Transfer Protocol) for sending the email alert no!fica!ons. To use SMTP, the Administrator must configure a valid SMTP server for sending the email. · Navigate to Alerts & Logging > SMTP & SMS > SMTP Server. · Enter the IP address of the outgoing mail Server in the Server field. · If this mail server uses a Secure Connec"on, select its type. · Specify the IP port to use. The default SMTP Port is 25. · Op!onally enter a Sender email address. This will appear as the From address in all email no!fica!ons sent from this console server. Note: many SMTP servers check the sender's email address with the host domain name to verify the address as authen#c. So it may be useful to assign an email address for the console server such as consoleserver2@mydomian.com. Opengear User Manual. Page 180. · If the SMTP server requires authen!ca!on, enter the required Username and Password. · Op!onally, enter a Subject Line that will be sent with all email no!fica!ons. Note: some SMTP servers require a non-blank Subject field. · Click Apply. SMTP is ac!vated. 6.5.2. Send SMS alerts With any model console server you can use email-to-SMS services to send SMS alert no!fica!ons to mobile devices. Almost all mobile phone carriers provide an SMS gateway service that forwards email to mobile phones on their networks. There's also a wide selec!on of SMS gateway aggregators which provide email to SMS forwarding to phones on any carriers. Alternately if your console server has an embedded or externally a%ached cellular modem you will be given the op!on to send the SMS directly over the carrier connec!on. SMS via e-mail gateway To use SMTP SMS the Administrator must configure a valid SMTP server for sending the email. · Navigate to Alerts & Logging > SMTP & SMS. · Select the SMS Gateway radio bu%on in the SMS Se!ngs sec!on. An SMS via Email Gateway sec!on will appear. · Enter the IP address of the outgoing SMS gateway Server. · Select a Secure Connec"on (if applicable). Opengear User Manual. Page 181. · specify the SMTP port to be used. The default SMTP Port is 25. · Op!onally enter a Sender email address. This will appear as the From address in all email no!fica!ons sent from this console server. Note: some SMS gateway service providers only forward email to SMS when the email has been received from authorized senders. So you may need to assign a specific authorized email address for the console server. · If the SMTP server requires authen!ca!on, enter the required Username and Password. · Op!onally, enter a Subject Line that will be sent with all no!fica!ons. Note: generally the email subject will contain a truncated version of the alert no#fica#on message (which is contained in full in the body of the email). However some SMS gateway service providers require blank subjects or require specific authen#ca#on headers to be included in the subject line. · Click Apply Se!ngs. The SMS-SMTP connec!on is ac!vated. SMS via cellular modem To use an a%ached or internal cellular modem for SMS the Administrator must enable SMS. · Navigate to Alerts & Logging > SMTP & SMS. · Select the Cellular Modem radio bu%on in the SMS Se!ngs sec!on. · Check Receive Messages to enable incoming SMS messages to be received. A custom script will be called on receipt of incoming SMS messages. Opengear User Manual. Page 182. · You may need to enter the phone number of the carrier's SMS Message Centre Only enter this if advised by your carrier or by Opengear support. · Click Apply Se!ngs. The SMS-SMTP connec!on is ac!vated. Note: the op#on to directly send SMS alerts via the cellular modem was included in the Management GUI as of firmware v3.4. Advanced console servers have had the gateway so(ware (SMS Server Tools 3) embedded since firmware v3.1 however you this could only be accessed from the command line to send SMS messages. see the Opengear FAQ for more. 6.5.3. Sends SNMP trap alerts The Administrator can configure the Simple Network Management Protocol (SNMP) agent that resides on the console server to send SNMP trap alerts to an NMS management applica!on. · Navigate to Alerts & Logging > SNMP. · Click the Primary SNMP Manager tab. The Primary SNMP Manager and Secondary SNMP Manager tabs are used to configure where and how outgoing SNMP alerts and no!fica!ons are sent. If you require your console server to send alerts via SNMP a Primary SNMP Manager must be configured. Op!onally, a second SNMP Network Manager, with its own SNMP se$ngs, can be specified on the Secondary SNMP Manager tab. Note: console servers can also be configured to provide status informa#on on demand using snmpd. This SNMP agent is configured using the SNMP Service Detail at Alerts & Logging > SNMP. See chapter 14 for more. · Select the Manager Protocol. SNMP is generally a UDP-based protocol though infrequently it uses TCP instead. · Enter the host address of the SNMP Network Manager in the Manager Address field. · Enter the TCP/IP port number into the Manager Trap Port field By default this port number is 162. Opengear User Manual. Page 183. · Select the Version to be used. The console server SNMP agent supports SNMP v1, v2 and v3. · Enter the Community name for SNMP v1 or SNMP v2c. At a minimum, a community needs to be set for either SNMP v1 or v2c traps to work. An SNMP community is the group to which devices and management sta!ons running SNMP belong. It helps define where informa!on is sent. SNMP default communi!es are private for Write and public for Read. · If required, configure SNMP v3. For SNMP v3 messages, the user's details and security level must match what the receiving SNMP Network Manager is expec!ng. SNMP v3 mandates that the message will be rejected unless the SNMPv3 user sending the trap already exists in the user database on the SNMP Manager. The user database in a SNMP v3 applica!on is actually referenced by a combina!on of the Username and the Engine ID for the given SNMP applica!on you are talking to. Opengear User Manual. Page 184. · Enter the Engine ID for the user sending messages. This is a hex number. For example: 0x8000000001020304. · Specify the Security Level. The security level has to be compa!ble with the se$ngs of the remote SNMP Network Manager. security level noAuthNoPriv authNoPriv authPriv meaning No authen!ca!on or encryp!on Authen!ca!on only. An authen!ca!on protocol (SHA or MD5) and password are required. Authen!ca!on and encryp!on. Requires an encryp!on protocol (DES or AES) and an authen!ca!on protocol password. · Complete the Username. This is the Security Name of the SNMPv3 user sending the message. This field is mandatory and must be completed when configuring the console server for SNMPv3. · If the required Security Level is authNoPriv or authPrive, select an Authen"ca"on Protocol (either SHA or MD5) and an Authen"ca"on Password. The password must contain at least 8 characters. · If the required Security Level is authPriv, select a Privacy Protocol (DES or AES). AES is recommended. A password of at least 8 characters must be provided for encryp!on to work. · Click Apply. Note: Console servers with firmware v3.0 and later also embed the net-snmpd dæmon. This dæmon can accept SNMP requests from remote SNMP management servers and provides informa#on on alert status, serial port status and device status (see chapter 14.5 for more details). Console servers with firmware earlier than v3.3 can only configure a Primary SNMP server from the Management Console. See chapter 14.5 for details on configuring the snmptrap daemon to send traps/no#fica#ons to mul#ple remote SNMP servers. As of firmware v3.10.2, new SNMP status and trap MIBS were created to provide more and be%er structured SNMP status and traps from console servers. There is an op!on in Alerts & Logging > SNMP to Use Legacy No"fica"ons for the SNMP traps. Se$ng this op!on sets the console server to SNMP traps that are compa!ble with those sent in older firmware before the new MIBS were added. Se$ng this op!on ensures a firmware upgrade to v3.10.2 or later does not break exis!ng SNMP management. When upgrading from firmware which does not support the newer SNMP MIBs/traps (that firmware versions before 3.10.2) to firmware that does support the new MIBs/traps: Opengear User Manual. Page 185. If the SNMP service was enabled and an SNMP manager was configured before upgrading the firmware, the console server will be configured to use the legacy traps a&er upgrading If the SNMP service was not enabled or no SNMP manger was configured before the upgrade, the console server will be configured to use the new SNMP traps a&er the upgrade. This won't have any effect un!l the SNMP service is turned on and an SNMP manager is configured. 6.5.4. Send Nagios event alerts To no!fy the central Nagios server of Alerts, NSCA must be enabled under System > Nagios and Nagios must be enabled for each applicable host or port under Serial & Network > Network Hosts or Serial & Network > Serial Ports (see chapter 9). Note: in a Lighthouse CMS centrally managed environment you can check the Nagios alert op#on. On the trigger condi#on (for matched pa"erns, logins, power events and signal changes) an NSCA check warning result will be sent to the central Nagios server. This condi#on is displayed on the Nagios status screen and triggers a no#fica#on, which can then cause the Nagios central server itself to send out an email or an SMS, page, etc. 6.6. Logging The console server can maintain log records of auto-response events. It can also log records of all access and communica!ons events with both the console server and with a%ached serial, network and power devices. A log of all system ac!vity is also maintained by default, as is a history of the status of any a%ached environmental monitors. 6.6.1. Log storage Before ac!va!ng any Event, Serial, Network or UPS logging, you must specify where those logs are to be saved. These records are stored off-server or in the ACM/IM gateway USB flash memory. · Navigate to Alerts & Logging > Port Log. Opengear User Manual. Page 186. · Specify the Server Type to be used. · add the required server details to enable log server access. The Administrator can view serial, network, and power device logs stored in the console reserve memory (or on a USB-connected flash device) in Manage > Devices. A User will only see logs for the Managed Devices they (or their Group) have been given access privileges for (see chapter 12). View USB event logs in a web terminal or by ssh or telnet to the console server. 6.6.2. Serial port logging In Console Server mode, ac!vity logs can be maintained of all serial port ac!vity. To specify which serial ports are to have ac!vi!es recorded and to what level data is to be logged: · navigate to Serial & Network > Serial Port. · click Edit for the port to be logged. · Specify the Logging Level for each port. level user connec"on events data transferred to the port 0 not logged not logged 1 logged not logged 2 logged logged 3 logged not logged 4 logged logged data transferred from hardware flow the port control changes not logged not logged not logged not logged logged logged logged logged not logged logged Note: logging levels are not a progression from no logging to all logging. Logging Level 0 is no logging, but Logging Level 4 is not `more' logging than Logging Level 3: these two levels, for example, are different but 4 is not a more comprehensive amount of logging than 3. · click Apply. Note: in addi#on to the Logs which are transmi"ed for remote/USB flash storage, a cache of the most recent 8K of logged data per serial port is maintained locally. To view the local cache of logged serial port data select Manage > Port Logs. Opengear User Manual. Page 187. 6.6.3. Network TCP & UDB port logging The console server supports op!onal logging of access to and communica!ons with network a%ached Hosts. For each Host, when you set up the Permi%ed Services which are authorized to be used, you also must set up the level of logging that is to be maintained for each service. · Specify the logging level that is to be maintained for that par!cular TDC/UDP port/service, on that par!cular Host: level what is logged 0 Turns off logging for the selected TDC/UDP port to the selected Host. 1 Logs all connec!on events to the port. 2 Logs all data transferred to and from the port. · Click Add. · click Apply. 6.6.4. Auto-response event logging · Navigate to Alerts & Logging > Auto-Response. · In the Global Auto-Response Se!ngs sec!on, check the Log Events check box. · Click Save Se!ngs. 6.6.5. Power device logging The console server also logs access and communica!ons with network a%ached hosts and maintain a history of the UPS and PDU power status. To ac!vate and set the desired levels of logging for UPS and PDU devices see chapter 7. Opengear User Manual. Page 188. 7.Power, environment, & digital I/O Opengear console servers manage Remote Power Control devices (RPCs including PDUs and IPMI devices) and Uninterrup!ble Power Supplies (UPSes). They also monitor remote opera!ng environments using Environmental Monitoring Devices (EMDs) and sensors, and can provide digital I/O control. 7.1. Remote power control (RPC) The console server Management Console monitors and controls Remote Power Control (RPC) devices using the embedded PowerMan and Network UPS Tools open source management tools and Opengear's power management so&ware. RPCs include power distribu!on units (PDUs) and IPMI power devices. Serial PDUs invariably can be controlled using their command line console, so you could manage the PDU through the console server using a remote Telnet client. Also you could use proprietary so&ware tools no doubt supplied by the vendor. This generally runs on a remote Windows PC and you could configure the console server serial port to operate with a serial COM port redirector in the PC (as detailed in chapter 3). Similarly, network-a%ached PDUs can be controlled with a browser (with SDT as detailed in chapter 5.3) or an SNMP management package or using the vendor supplied control so&ware. Also servers and network-a%ached appliances with embedded IPMI service processors or BMCs invariably are supplied with their own management tools (like SoL) that provide secure management when connected using with SDT Connector. For simplicity, however, all these devices can now all be controlled through the one window using the Management Console's RPC remote power control tools. Opengear User Manual. Page 189. 7.1.1. RPC connec"on Serial and network connected RPCs must first be connected to, and configured to communicate with, the console server. · For serial RPCs connect the PDU to the selected serial port on the console server. · Navigate to Serial & Network > Serial Port. · Configure the Common Se!ngs of that port with the RS232 proper!es etc required by the PDU (see chapter 3.1.1). · Select RPC as the Device Type. · Similarly for each network connected RPC, go to Serial & Network > Network Hosts and configure the RPC as a connected Host by specifying its Device Type as RPC · click Apply. See chapter 4.4 for more on Network Hosts. · Navigate to Serial & Network > RPC Connec"ons. The RPC connec!ons that have already been configured will present. · Click Add RPC. · Connected Via presents a list of serial ports and network Host connec!ons that you have set up with device type RPC but have yet to connect to a specific RPC device. Opengear User Manual. Page 190. · When you select Connected Via for a Network RPC connec!on, the corresponding Host Name/Descrip"on set up for that connec!on will be entered as the Name and Descrip"on for the power device. · Alterna!vely if you select Serial connec!on for Connected Via, you will need to enter a Name and Descrip!on for the power device. · Select the appropriate RPC Type for the PDU (or IPMI) being connected. If you are connec!ng to the RPC via the network you will be presented with the IPMI protocol op!ons and the SNMP RPC Types currently supported by the embedded Network UPS Tools. If you are connec!ng to the RPC by a serial port you will be presented with all the serial RPC types currently supported by the embedded PowerMan and Opengear's power manager. · Enter the Username and Password used to login into the RPC These login creden!als are not related to the Users and access privileges configured in Serial & Networks > Users & Groups. · If SNMP protocol is selected enter the SNMP v1 or v2c Community for Read/Write access. By default this would be private. · Check Log Status. Opengear User Manual. Page 191. · Secify the Log Rate (minutes between samples) if you wish the status from this RPC to be logged. These logs can be views from Status > RPC Status. · Click Apply. For SNMP PDUs the console server will now probe the configured RPC to confirm the RPC Type matches and will report the number of outlets it finds that can be controlled. If unsuccessful it will report Unable to probe outlets and you will need to check the RPC se$ngs, the network connec!on or the serial connec!on. For serially connected RPC devices, a new Managed Device (with the same name as given to the RPC) will be created. The console server will then configure the RPC with the number of outlets specified in the selected RPC Type or will query the RPC itself for this informa!on. Note: Opengear's console servers support the majority of the popular network and serial PDUs. If your PDU is not on the default list then support can be added directly (see chapter 14) or by having the PDU supported added to either the Network UPS Tools or PowerMan open source projects. IPMI service processors and BMCs can be configured so all authorized users can use the Management Console to remotely cycle power and reboot computers, even when their opera!ng system is unresponsive. To set up IPMI power control: · enter the IP address or domain name of the BMC or service processor (for example, a Dell DRAC) in Serial & Network > Network Hosts. · then in Serial & Network > RPC Connec"ons specify the RPC Type to be IPMI1.5 or 2.0. 7.1.2. RPC access privileges & alerts Opengear User Manual. Page 192. Set PDU and IPMI alerts using Alerts & Logging > Alerts (see chapter 6). Assign users to access and control outlets on each RPC via Serial & Network > User & Groups (see chapter 3). 7.1.3. User power management The Power Manager allows users and administrators to access and control configured serial- & network-a%ached PDU power strips, and servers with embedded IPMI processors or BMCs. · Select Manage > Power. · Select the Target power device to be controlled. · If the RPC supports outlet level control, select the Outlet to be controlled. · Ini!ate the desired Ac!on by selec!ng the appropriate icon: Note: icons will present only for opera#ons that are supported by the Target you have selected. Turn On. Turn Off. Cycle. Status. Opengear User Manual. Page 193. 7.1.4. RPC status You can monitor the current status of your network and serially connected PDUs and IPMI RPCs. · Select Status > RPC Status. A table with the summary status of all connected RPC hardware will display. · Click on View Log or select the RPCLogs tab. A table of the history and detailed graphical informa!on on the selected RPC will present. · Click Manage to query or control the individual power outlet. This will take you to Manage > Power. 7.2. Uninterrup"ble power supply (UPS) control Opengear console servers can be configured to manage locally and remotely connected UPS hardware using Network UPS Tools. Network UPS Tools (NUT) is a group of open source programs that provide a common interface for monitoring and administering UPS hardware; and ensuring safe shutdowns of the systems which are connected. NUT is built on a networked model with a layered scheme of drivers, server and clients. It is covered in some detail in chapter 7.2.6. 7.2.1. Managed UPS connec"ons Opengear User Manual. Page 194. A Managed UPS is a UPS that is directly connected as a Managed Device to the console server. It can be connected by serial or USB cable or by the network. The console server becomes the master of this UPS, and runs a upsd server to allow other computers that are drawing power through the UPS (slaves) to monitor the UPS status and take appropriate ac!on, such as shutdown, in event of low UPS ba%ery. The console server may or may not be drawing power itself through the Managed UPS. When the UPS's ba%ery power reaches cri!cal, the console server signals, waits for slaves to shut down, then powers off the UPS. Serial and network connected UPSes must first be connected to, and configured to communicate with the console server. For serial UPSes a%ach the UPS to the selected serial port on the console server: · navigate to Serial and Network > Serial Port. Opengear User Manual. Page 195. · configure the Common Se!ngs of that port with the proper!es (RS232 etc) required by the UPS (see chapter 3.1.1). · select UPS as the Device Type. For each network connected UPS: · navigate to Serial & Network > Network Hosts. · configure the UPS as a connected Host by specifying its Device Type as UPS. · click Apply. Note: USB-connected UPS hardware requires no equivalent configura#on. · Navigate to Serial & Network > UPS Connec"ons. The Managed UPSes sec!on will display all UPS connec!ons which have already been configured. · Click Add Managed UPS. · Select if the UPS will be Connected Via USB or over a pre-configured serial port or via SNMP/HTTP/HTTPS over the preconfigured network Host connec!on. Note: when you select a network UPS connec#on, the corresponding Host Name/Descrip#on that you set up for that connec#on will be entered as the Name and Descrip#on for the power device. Alterna#vely, if you select to Connect Via a USB or serial connec#on you will need to enter a Name and Descrip#on for the power device. These details will also be used to create a new Managed Device entry for the serial/USB connected UPS devices. · Enter the login details. This Username and Password is used by slaves of this UPS (that is, other computers that are drawing power through this UPS) to connect to the console server to monitor the UPS status so they can shut themselves down when ba%ery power is low. Monitoring will typically be performed using the upsmon client running on the slave server (see chapter 7.2.3). Note: these login creden#als are not related to the Users and access privileges configured in Serial Opengear User Manual. Page 196. & Networks > Users & Groups. · Select the ac!on to take when UPS ba%ery power becomes cri!cal: Shut down the UPS or Shut down all Managed UPSes or simply Run un!l failure. the shutdown script /etc/scripts/ups-shutdown can be customized so, in the event of a cri!cal power failure (when the UPS ba%ery runs out) you can program the console server to perform last gasp ac!ons before power is lost. See the Opengear FAQ for details. It is generally simpler, however, to perform such last gasp ac!ons by triggering Auto-Response on the UPS hi$ng ba$ or lowba$. See chapter 6. · If you have mul!ple UPSes and require them to be shut down in a specific order, specify the Shutdown Order for this UPS. This is a whole posi!ve number, a 0 or -1. 0s are shut down first, then 1s, 2s, 3s and so on. -1s are not shut down at all. The default value is 0. · Select the Driver that will be used to communicate with the UPS. · Click New Op"ons in Driver Op"ons if you need to set driver-specific op!ons for your selected NUT driver and hardware combina!on. Opengear User Manual. Page 197. For more details see h%p://www.networkupstools.org/doc. · Check Log Status and specify the Log Rate (minutes between samples) if you wish the status from this UPS to be logged. These logs can then be viewed at Status > UPS Status. If you have enabled Nagios services you will presented with an op!on for Nagios monitoring. · Check Enable Nagios to enable this UPS to be monitored using Nagios central management. · Check Enable Shutdown Script if this is the UPS providing power to the console server itself. In the event of a cri!cal power failure you can perform last gasp ac!ons on the console server before power is lost. This is achieved by placing a custom script in /etc/config/scripts/ups-shutdown (you may use the provided /etc/scripts/ups-shutdown as a template). This script is only run when then UPS reaches cri!cal ba%ery status. Click Apply. Note: you can customize the upsmon, upsd and upsc se&ngs for this UPS hardware directly from the command line. 7.2.2. Remote UPS management A Remote UPS is a UPS that is connected as a Managed Device to some remote console server which is being monitored (but not managed) by your console server. The upsc and upslog clients in the Opengear console server can configured to monitor remote servers that are running Network UPS Tools managing their locally connected UPSes. These remote servers might be other Opengear console servers or generic Linux servers running NUT. So all these distributed UPSes (which may be spread in a row in a data center, or around a campus property or across the country) can be centrally monitored through the one central console server window. An example where centrally monitoring remotely distributed UPSes is useful is a campus or large business complex where there's a mul!tude of computer and other equipment sites spread afar, each with their own UPS supply. Many of these (par!cularly the smaller sites) will be USB or serially connected. Having a ACM5000 or ACM5500 at these remote sites allows the systems manager to centrally monitor the power supply status at all sites, centralize alarms, and, consequently, be warned to ini!ate a call-out or take shut down ac!ons. To add a Remote UPS: Opengear User Manual. Page 198. · navigate to Serial & Network > UPS. The Remote UPSes sec!on displays all the remote UPS devices being monitored · click Add Remote UPS. · enter the UPS Name of the remote UPS to be remotely monitored. This name must be the name that the remote UPS was configured with on the remote console server as the remote console server may itself have mul!ple UPSes a%ached that it is managing locally with NUT. · op!onally enter a Descrip!on. · enter the IP Address or DNS name of the remote console server that is managing the remote UPS. This may be another Opengear console server or it may be a generic Linux server running Network UPS Tools. · check Log Status. · specify the Log Rate (minutes between samples) if you wish the status from this UPS to be logged. These logs can then be viewed at Status > UPS Status. Opengear User Manual. Page 199. · check Enable Shutdown Script if this remote UPS is the UPS providing power to the console server itself. In the event the UPS reaches cri!cal ba%ery status the custom script in /etc/config/ scripts/ups-shutdown is run enabling you to perform any `last gasp' ac!ons. click Apply. Note: the Remote UPS feature is supported on all console servers running firmware v2.8 and later. Earlier versions supported a single remote ]Monitored UPS which could be set to trigger the console server shutdown script. 7.2.3. Controlling UPS-powered computers One of the advantages of having a Managed UPS is that you can configure computers that draw power through that UPS to be shut down gracefully in the event of UPS problems. For Linux computers this can be done by se$ng up upsmon on each computer and direc!ng them to monitor the console server that is managing their UPS. This will set the specific condi!ons that will be used to ini!ate a power down of the computer. For example, non-cri!cal servers may be powered down some seconds a&er the UPS starts running on ba%ery where more cri!cal servers may not be shut down un!l a low ba%ery warning is received. Refer to the online NUT documenta!on for details on how this is done: h%p://eu1.networkupstools.org/doc/2.2.0/INSTALL.html h%p://linux.die.net/man/5/upsmon.conf h%p://linux.die.net/man/8/upsmon An example upsmon.conf entry might look like: MONITOR managedups@192.168.0.1 1 username password slave upsmon.conf por"on meaning manageup The UPS Name of the managed UPS. 192.168.0.1 1 The IP address of the Opengear console server. Indicates the server has a single power supply a%ached to this UPS. username The username of the managed UPS. password The password of the managed UPS. There are NUT monitoring clients available for Windows computers (for example, WinNUT). If you have an RPC (PDU) it is also possible to shut down UPS-powered computers and other equipment without them have a client running (for example, communica!ons and surveillance gear). Set up a UPS alert and use this to trigger a script which controls a PDU to shut off the power (see chapter 14). 7.2.4. UPS alerts Set UPS alerts using Alerts & Logging > Alerts. See chapter 6. 7.2.5. UPS status Opengear User Manual. Page 200. You can monitor the current status of your network-connected, serially-connected or USBconnected Managed UPSes and any configured Remote UPSes. · Navigate to Status > UPS Status. A table with the summary status of all connected UPS hardware will display. · Click on any given UPS System name in the table. More detailed graphical informa!on on the select UPS System will present. · Click on any given UPS System's All Data link in the table. Status and configura!on informa!on on the selected UPS System presents. · Select UPS Logs. The log table of the load, ba%ery charge level, temperature and other status informa!on Opengear User Manual. Page 201. from all the managed and monitored UPS systems is presented. This informa!on is logged for all UPSes which were configured with Log Status checked. The informa!on is also presented graphically. 7.2.6. Overview of Network UPS tools (NUT) Network UPS Tools (NUT) is built on a networked model with a layered scheme of drivers, server and clients. NUT can be configured using the Management Console as described above, or you can configure the tools and manage the UPSes directly from the command line. This sec!on provides an overview of NUT., Full NUT documenta!on is available at h%p:// networkupstools.org/documenta!on.html. The driver programs talk directly to the UPS equipment and run on the same host as the NUT network server (upsd). Drivers are provided for a wide assortment of equipment from most of the popular UPS vendors and understand the specific language of each UPS. They communicate to serial-, USB- and SNMP network- connected UPS hardware and map the communica!ons back to a compa!bility layer. This means both an expensive `smart' protocol UPS and a simple `power strip' model can be handled transparently. The NUT network server program upsd is responsible for passing status data from the drivers to the client programs via the network. upsd can cache the status from mul!ple UPSes and then serve this status data to many clients. upsd also contains access control features to limit the abili!es of the clients (for example, so only authorized hosts may monitor or control the UPS hardware). There are a number of NUT clients that connect to upsd to check on the status of the UPS hardware and do things based on the status. These clients can run on the same host as the NUT server or they can communicate with the NUT server over the network (enabling them to monitor any UPS anywhere). Opengear User Manual. Page 202. · The upsc client provides a quick way to poll the status of a UPS server. It can be used inside shell scripts and other programs that need UPS data but don't want to include the full interface · The upsmon client enables servers that draw power through the UPS to shutdown gracefully when the ba%ery power reaches cri!cal · There are also logging clients (upslog) and third party interface clients (Big Sister, Cac!, Nagios, Windows and more). The latest release of NUT (2.7.4) also controls PDU systems. It can do this either na!vely using SNMP or through a binding to Powerman (open source so&ware from Livermore Labs that is also embedded in Opengear console servers). These NUT clients and servers are all embedded in each Opengear console server (with a Management Console presenta!on layer added). They also run remotely on distributed console servers and other remote NUT monitoring systems. This layered distributed NUT architecture enables: · Mul!ple manufacturer support. NUT can monitor UPS models from 79 different manufacturers and PDUs from a growing number of vendors, all via a unified interface. · Mul!ple architecture support. NUT can manage serial- and USB-connected UPS models with the same common interface. Network-connected USB and PDU equipment can also be monitored using SNMP. · Mul!ple clients monitoring the one UPS. Mul!ple systems may monitor a single UPS using only their network connec!ons. As well there is a wide selec!on of client programs which support monitoring UPS hardware via NUT (Big Sister, Cac!, Nagios and more). · Central management of mul!ple NUT servers. A central NUT client can monitor mul!ple NUT servers that may be distributed throughout the data center, across a campus or around the world. NUT supports the more complex power architectures found in data centers, communica!ons centers and distributed office environments where: UPSes from many vendors power many systems with many clients; and larger UPSes power mul!ple devices; and many of these UPSes are, in turn, dual powered. 7.3. Environmental monitoring Opengear console servers can be configured to monitor their opera!ng environment. External Environmental Monitor Devices (EMDs) can be connected to any Opengear console Opengear User Manual. Page 203. server serial port. Each console server can support mul!ple EMDs. Each EMD device has an internal temperature and humidity sensor plus one or two general purpose status sensor ports which can be connected to smoke detectors, water detectors, vibra!on sensors or open-door sensors. The ACM5000 and ACM5500 advanced console server models also each have an internal temperature sensor and can op!onally be configured to have up to four general purpose status sensor ports (which can be connected to smoke detectors, water detectors, vibra!on sensors, or open-door sensors) directly connected. Using the Management Console, Administrators can view the ambient temperature (in °C or °F) and humidity (as a percentage) and configure alerts to monitor the status and sensors to automa!cally send alarms progressively from warning levels to cri!cal. 7.3.1. Connec"ng the EMD & its sensors The Environmental Monitor Device (EMD) connects to any serial port on the console server via a special EMD Adapter and standard CAT5 cable. The sensors then screw into the EMD. Note: the EMD is powered over the serial port connec#on and communicates using a custom handshake protocol. It is not an RS232 device and should not be connected without the adapter. · Plug the male RJ plug on the EMD Adapter into the EMD. · Connect the Adapter to the console server serial port using the provided UTP cable. If the 2 meter (6) UTP cable provided with the EMD is not long enough it can be replaced with a standard Cat5 UTP cable up to 10 meters (33) in length. · Screw the bare wires on any smoke detector, water detector, vibra!on sensor, open-door sensor or general purpose open/ close status sensors into the terminals on the EMD. Note: you can a"ach two sensors onto the terminals on EMDs that are connected to console servers with Opengear Classic pinouts. However console servers with -01 and -02 pinouts only support a"aching a single sensor to each EMD. EMDs work with Opengear console servers only and cannot be connected to standard RS232 serial ports on other appliances. · Navigate to Serial & Network > Serial Port. · Select Environmental as the Device Type. No par!cular se$ngs are required. Opengear User Manual. Page 204. · Click Apply. 7.3.2. Connec"ng sensors to ACM5000s, ACM5500s, & ACM7000s You can connect EMDs (and their a%ached environmental sensors) to the ACM5000's serial ports, as detailed above. ACM5000s also supports direct environmental sensor connec!on. All ACM5000 models (except the ACM5004-2-I) can be configured with the environmental op!on E. Models with this op!on have a green connector block on the side (marked SENSORS 1 -4) and up to four environmental sensors can be directly a%ached to this block. The ACM5004-2-I model is supplied with a green connector block on the side by default. The first two connectors on this block (marked DIO1 and DIO2) can be configured to have external environmental sensors a%ached. ACM5508-2-I and ACM5504-5-G-I models also ship with a green connector block on the side. The first two connectors on this block (marked DIO1 and DIO2) can be configured to have external environmental sensors a%ached. ACM7000 models ship with an in-built, black, spring cage I/O connector block for a%aching environmental sensors and digital I/O devices. ACM5000-E sensor inputs are four dry contact inputs. These are normally open (NO) and sensed as TTL high or digital 1. When ac!vated, external devices (door close, vibra!on, water, smoke) present a short circuit, the contact closes to ground and is read as TTL low or digital 0. For custom applica!ons the state (closed or open) of non-Opengear dry contact sensors can be sensed through the UI or command line.The sensor pins can also be controlled as outputs: set the pins as TTL high (1) or low (0) as required for their low voltage/low current applica!on. ACM5000s and ACM5000 -Is have dedicated I/O (DIO1 & DIO2) and output only pins (OUT1 & OUT2), the la%er having inver!ng outputs with higher voltage/current transistor. By default each SENSOR and DIO port is configured as an Input for external environmental sensors. · To confirm the direc!on and state configura!ons for these ports navigate to System > I/O. A table with the summary status of the four digital I/O ports will present. port label I/O Port 1 I/O Port 2 I/O Port 3 I/O Port 4 equivalent hardware label DIO1 or SENSOR1 DIO2 or SENSOR2 SENSOR3 SENSOR4 · Screw the bare wires on a smoke detector, water detector, vibra!on sensor, open-door sensor or general purpose open/close status sensor into the SENSOR or DIO terminals on the green connector block. As Inputs, the SENSOR and DIO ports are no!onally a%ached to the internal EMD. Opengear User Manual. Page 205. · Navigate to Serial & Network > Environmental Status. · Enable the Internal EMD. · Configure the a%ached sensors as alarms. Details for doing this are covered in the next sec!on. 7.3.3. Adding EMD & configuring the sensors · Navigate to Serial & Network > Environmental. This will display external EMDs and internal EMD (that is, sensors that may be directly a%ached to an ACM) that have already been configured. · To add a new EMD click Add. · enter a Name. · Op!onally enter a Descrip"on. · Select the pre-configured serial port that the EMD will be Connected Via. · Op!onally calibrate the EMD with a Temperature Offset (+ or - °C) or Humidity Offset (+ or percent). Opengear User Manual. Page 206. Note: if you check Temperature in Fahrenheit the temperature will be reported in Fahrenheit. Otherwise it will be reported in degrees Celsius. · Provide Labels for each of the alarm sensors used (for example, Door Open or Smoke Alarm). · Check Log Status. · Specify the Log Rate (minutes between samples) if you wish the status from this EMD to be logged. These logs can be viewed at Status > Environmental Status. · Click Apply. This will also create a new Managed Device with the same name. · For the ACM5000-E select Serial & Network > Environmental. Opengear User Manual. Page 207. · check Enabled. · Set temperature offsets and label the sensors as described above. 7.3.4. Environmental alerts Set temperature, humidity and probe status alerts using Alerts & Logging> Alerts. See chapter 6. 7.3.5. Environmental status You can monitor the current status of any and all configured external EMDs and their sensors, and any internal or directly a%ached sensors. · Navigate to Status > Environmental Status. A table with the summary status of all connected EMD hardware will display. · Click on View Log or click the Environmental Logs tab. A table and graphical plot of the log history of the select EMD will present. Opengear User Manual. Page 208. 7.4. Digital I/O ports ACM5000 -I models and ACM5500 -I models have four digital interface ports which present on a green connector block on the side of the unit. DIO1 and DIO2 are two TTL level digital I/O ports: 5V max @ 20mA. OUT1 and OUT2 are two High-Voltage digital output ports: >5V to <= 30V @100mA. ACM7000 models ship with an in-built, black, spring cage I/O connector block for a%aching environmental sensors and digital I/O devices. These I/O ports are configured via System > I/O Ports. Each port can be configured with a default direc!on and state. · Navigate to System > I/O Ports. 7.4.1. Digital I/O output configura"on Each of the two digital I/O ports (DIO1 and DIO2) can be configured as an Input or Output port. To use them as digital outputs first configure the port direc!on on System > I/O Ports. The DIO1 and DIO2 pins are current limited by the chip to 20mA and accept 5V levels, so they cannot, for example, drive a relay. Opengear User Manual. Page 209. You can change the output states using the ioc command line u!lity. The following text is the ioc help text (also available by running ioc --help): -p pin_num pin number (1 to 4) -d pin_dir pin direction (0 = output 1 = input) -v pin_val pin electrical value in output mode \ (0 = low 1 = high) -r reset pins to all inputs and low -g displays the pin directions and current values -l load pin configuration from configlity For example, to set pin 1 to a low output, type: ioc -p 1 -d 0 -v 0 To pulse one of these outputs, use a script like the following: ioc -p 1 -d 0 -v 1 sleep 1 ioc -p 1 -d 0 -v 0 This sets the output high for 1 second, then returns it to low (assuming the ini!al state is low). 7.4.2. Digital I/O input configura"on When either of the two digital I/O (DIO1 & DIO2) outlets is configured as an Input on the System > I/O Ports, it can be used to monitor the current status of any a%ached sensor. When configured as inputs (the factory default) these first two ports are no!onally a%ached to an internal EMD. To configure them as alarms, go to the Status > Environmental Status and edit and enable the Internal EMD. Note: the low voltage circuits in DIO1 and DIO2 should not be wired to voltages greater than 5V DC. ALterna!vely, these input ports can be monitored using the ioc command line u!lity (as detailed in 7.4.1 above). 7.4.3. High-voltage outputs OUT1 and OUT2 (internally, DIO3 & DIO4) outlets are wired as high voltage outputs. The way these outputs are expected to be used is to pull a power connected line to ground (that is, the OUT1 and OUT2 transistors are open collector). The I/O port header includes a 12v reference line (VIN) which can be used to detect the line state change. For example, to light a 12v LED using the high voltage outputs, connect the posi!ve leg of the LED to the 12v reference, and the nega!ve leg to output pin 4. Due to the way that the I/O port is connected internally, the output has to be set high to pull the output to ground. The following command will switch on the led: ioc -p 4 -d 0 -v 1 OUT1 and OUT2 transistors can operate with a supply of >5V to <= 30V @100mA. This Opengear User Manual. Page 210. means to drive a relay circuit you must guarantee it doesn't provide more than 100mA when set to 1. 7.4.4. DIO SNMP status As of firmware v3.9, there is a SNMP status table which reports on the status of the digital IO ports. The table's OID is OG-STATUSv2-MIB::ogEmdDioTable. Performing an snmpwalk on this table on a console server with DIO produces something like the following (the specifics will vary depending on device status): $ snmpwalk -v2c -c public -M $MIBSDIR -m ALL t5:161 1.3.6.1.4.1.25049.16.5 OG-STATUS-MIB::ogDioStatusName.1 = STRING: DIO 1 OG-STATUS-MIB::ogDioStatusName.2 = STRING: DIO 2 OG-STATUS-MIB::ogDioStatusName.3 = STRING: DIO 3 OG-STATUS-MIB::ogDioStatusName.4 = STRING: DIO 4 OG-STATUS-MIB::ogDioStatusType.1 = INTEGER: ttlInputOutput(0) OG-STATUS-MIB::ogDioStatusType.2 = INTEGER: ttlInputOutput(0) OG-STATUS-MIB::ogDioStatusType.3 = INTEGER: highVoltageOutput(1) OG-STATUS-MIB::ogDioStatusType.4 = INTEGER: highVoltageOutput(1) OG-STATUS-MIB::ogDioStatusDirection.1 = INTEGER: input(1) OG-STATUS-MIB::ogDioStatusDirection.2 = INTEGER: input(1) OG-STATUS-MIB::ogDioStatusDirection.3 = INTEGER: input(1) OG-STATUS-MIB::ogDioStatusDirection.4 = INTEGER: input(1) OG-STATUS-MIB::ogDioStatusState.1 = INTEGER: low(0) OG-STATUS-MIB::ogDioStatusState.2 = INTEGER: high(1) OG-STATUS-MIB::ogDioStatusState.3 = INTEGER: high(1) OG-STATUS-MIB::ogDioStatusState.4 = INTEGER: high(1) OG-STATUS-MIB::ogDioStatusCounter.1 = Counter64: 0 OG-STATUS-MIB::ogDioStatusCounter.2 = Counter64: 0 OG-STATUS-MIB::ogDioStatusCounter.3 = Counter64: 0 OG-STATUS-MIB::ogDioStatusCounter.4 = Counter64: 0 OG-STATUS-MIB::ogDioStatusTriggerMode.1 = INTEGER: risingFallingEdge(3) OG-STATUS-MIB::ogDioStatusTriggerMode.2 = INTEGER: risingFallingEdge(3) OG-STATUS-MIB::ogDioStatusTriggerMode.3 = INTEGER: risingFallingEdge(3) OG-STATUS-MIB::ogDioStatusTriggerMode.4 = INTEGER: risingFallingEdge(3) Opengear User Manual. Page 211. 8. Authen!ca!on The console server pla*orm is a dedicated Linux computer, and it embodies a myriad of popular and proven Linux so&ware modules for networking, secure access (OpenSSH), secure communica!ons (OpenSSL) and sophis!cated user authen!ca!on (PAM, RADIUS, TACACS+, Kerberos and LDAP). This chapter details how the Administrator can use the Management Console to establish remote AAA authen!ca!on for all connec!ons to the console server and a%ached serial and network host devices. Opengear User Manual. Page 212. This chapter also covers establishing a secure link to the Management Console using HTTPS and using OpenSSL and OpenSSH for establishing secure Administra!on connec!on to the console server. More details on RSA SecurID and working with Windows IAS can be found in the FAQs at h%ps://opengear.zendesk.com/. 8.1. Authen"ca"on configura"on Authen!ca!on can be performed locally, or remotely using an LDAP, Radius, Kerberos or TACACS+ authen!ca!on server. The default authen!ca!on method for the console server is Local. Any authen!ca!on method that is configured will be used for authen!ca!on of any user who a%empts to log in through Telnet, SSH or the Web Manager to the console server and any connected serial port or network host devices. The console server can be configured to the default (Local) or an alternate authen!ca!on method (TACACS, RADIUS, LDAP or Kerberos) with the op!on of a selected order in which local and remote authen!ca!on is to be used. · Local/TACACS/RADIUS/LDAP/Kerberos Tries local authen!ca!on first, falling back to remote if local fails. · TACACS/RADIUS/LDAP/Kerberos Local Tries remote authen!ca!on first, falling back to local if remote fails. · TACACS/RADIUS/LDAP/Kerberos Down/Local Tries remote authen!ca!on first, falling back to local if the remote authen!ca!on returns an error condi!on (e.g. the remote authen!ca!on server is down or inaccessible). 8.1.1. Local authen"ca"on · Navigate to Serial and Network > Authen!ca!on. · Check Local. · Click Apply. 8.1.2. TACACS authen"ca"on Perform the following procedure to configure the TACACS+ authen!ca!on method to be used whenever the console server or any of its serial ports or hosts is accessed. · Select Serial and Network > Authen"ca"on. · check TACAS, LocalTACACS, TACACSLocal or TACACSDownLocal. · Enter the Server Address (IP or host name) of the remote Authen!ca!on/Authoriza!on server. Mul!ple remote servers may be specified in a comma separated list. Each server is tried in succession. Opengear User Manual. Page 213. · Session accoun!ng is on by default. If session accoun!ng informa!on is not wanted, check the Disable Accoun!ng checkbox. One reason for not wan!ng session accoun!ng: if the authen!ca!on server does not respond to accoun!ng requests, said request may introduce a delay when logging in. · In addi!on to mul!ple remote servers you can also enter for separate lists of Authen!ca!on/Authoriza!on servers and Accoun!ng servers. If no Accoun!ng servers are specified, the Authen!ca!on/Authoriza!on servers are used instead. · Enter and confirm the Server Password. · Select the method to be used to authen!cate to the server (defaults to PAP). To use DES encrypted passwords, select Login. · If required, enter the TACACS Group Membership A$ribute to be used to indicate group memberships (defaults to groupname#n). · If required, specify TACACS Service to authen!cate with. This determines which set of a%ributes are returned by the server (defaults to raccess). · If required, check Default Admin Privileges to give all TACAS+ authen!cated users admin privileges. · Use Remote Groups must also be !cked for these privileges to be granted. · The TACACS Privilege Level feature only applies to TACACS remote authen!ca!on. Opengear User Manual. Page 214. When Ignore Privilege Level is enabled, the priv-lvl se$ng for all of the users defined on the TACACS AAA server will be ignored. Note: An Opengear device normally interprets a user with a TACACS priv-lvl of 12 or above as an admin user. There is a special case where a user with a priv-lvl of 15 is also given access to all configured serial ports. When the Ignore Privilege Level op#on is enabled (that is, it is checked in the UI) there are no escala#ons of privileges based on the priv-lvl value from the TACACS server. Also: if the only thing configured for one or more TACACS users is the priv-lvl (for example, no specific port access or group memberships are set), then enabling this feature will revoke access to the console server for those users as the they won't be a member of any groups, even if the Retrieve Remote groups op#on in the Authen"ca"on menu is enabled. · Click Apply. TACAS+ remote authen!ca!on will now be used for all user access to console server and serially or network a%ached devices. The Terminal Access Controller Access Control System (TACACS+) security protocol is a protocol developed by Cisco. It provides detailed accoun!ng informa!on and flexible administra!ve control over the authen!ca!on and authoriza!on processes. TACACS+ allows for a single access control server (the TACACS+ daemon) to provide authen!ca!on, authoriza!on, and accoun!ng services independently. Each service can be !ed into its own database to take advantage of other services available on that server or on the network, depending on the capabili!es of the daemon. 8.1.3. RADIUS authen"ca"on The Remote Authen!ca!on Dial-In User Service (RADIUS) protocol was developed by Livingston Enterprises as an access server authen!ca!on and accoun!ng protocol. The RADIUS server can support a variety of methods to authen!cate a user. When it is provided with the username and original password given by the user, it can support PPP, PAP or CHAP, UNIX login, and other authen!ca!on mechanisms. More informa!on on configuring remote RADIUS servers can be found h%ps://freeradius.org/ and h%ps://cisco.com/c/en/us/support/docs/security-vpn/remote-authen!ca!on-dial-userservice-radius/12433-32.html. Perform the following procedure to configure the RADIUS authen!ca!on method to be used whenever the console server or any of its serial ports or hosts is accessed: · Select Serial & Network > Authen"ca"on and check RADIUS, LocalRADIUS, RADIUSLocal or RADIUSDownLocal. · Enter the Server Address (IP or host name) of the remote Authen"ca"on and Authoriza"on server. Mul!ple remote servers may be specified in a comma separated list. Each server is tried in succession. · Session accoun!ng is on by default. If session accoun!ng informa!on is not wanted, check the Disable Accoun"ng checkbox. Opengear User Manual. Page 215. One reason for not wan!ng session accoun!ng: if the authen!ca!on server does not respond to accoun!ng requests, said request may introduce a delay when logging in. · In addi!on to mul!ple remote servers, you can also enter separate lists of Authen"ca"on and Authoriza"on servers and Accoun"ng servers. If no Accoun"ng servers are specified, the Authen"ca"on and Authoriza"on servers are used instead. · Enter the Server Password. · Click Apply. RADIUS remote authen!ca!on will now be used for all user access to console server and serially or network a%ached devices. 8.1.4. LDAP authen"ca"on The Lightweight Directory Access Protocol (LDAP) is based on the X.500 standard, but significantly simpler and more readily adapted to meet custom needs. The core LDAP specifica!ons are all defined in RFCs. LDAP is a protocol used to access informa!on stored in an LDAP server. With firmware v3.11 and later, LDAP authen!ca!on now supports OpenLDAP servers, using the POSIX -style schema for user and group defini!ons. Performing simple authen!ca!on against any LDAP server (AD or OpenLDAP) is straight forward, as they both follow the common LDAP standards and protocols. The harder part is configuring how to get the extra data about the users (for example, the groups they are in). On an Opengear device, we may be configured to look at group informa!on from an LDAP server for authen!ca!on and authoriza!on. This group informa!on is poten!ally stored in a number of different ways. Ac!ve Directory has one method, and OpenLDAP has two other methods. Ac"ve Directory method Each entry for a user will have mul!ple memberOf a%ributes. Each memberOf value is the full DN of the group they belong to. (The entry for the user will be of objectClass user.) OpenLDAP/POSIX method 1 Opengear User Manual. Page 216. Each entry for a user must have a gidNumber a%ribute. This will be an integer value, which is the user's primary group (for example, mapping to the /etc/passwd file, with the group ID field). To determine which group this is, search for an entry in the directory that has that group ID, which will give the group name. (The users are of objectClass posixAccount, and the groups are of objectClass posixGroup.) OpenLDAP/POSIX method 2 Each group entry in the group tree of objectClass posixGroup may have mul!ple memberUid a%ributes. These represent secondary groups (for example, mapping to the /etc/groups file). Each a%ribute would contain a username. To cater for all these possibili!es, the pam_ldap module has been modified to do group lookups for each of these three styles. This allows us to have a rela!vely generic configura!on, and not be concerned with how the LDAP directory is set up. There are only two parameters that need to be configured, based on what the user wishes to look up: the LDAP username and group membership a%ributes. To clarify to the user what parameters to use, the descrip!ons for these fields have been updated to prompt the user for common or likely a%ributes. For example, the two configura!on fields have descrip!ons as follows: LDAP Username A$ribute: the LDAP a%ribute that corresponds to the login name of the user (commonly `sAMAccountName' for Ac!ve Directory, and `uid' for OpenLDAP). LDAP Group Membership A$ribute: the LDAP a%ribute that indicates group membership in a user record (commonly `memberOf' for Ac!ve Directory, and unused for OpenLDAP). Note: The libldap library is par#cularly fussy about ensuring SSL connec#ons are using cer#ficates signed by a trusted CA. Consequently it is o(en not easy to set up a connec#on to an LDAP Opengear User Manual. Page 217. server using SSL. See h"ps://opengear.zendesk.com/entries/29959515-LDAP-over-SSL for more. Perform the following procedure to configure the LDAP authen!ca!on method to be used whenever the console server or any of its serial ports or hosts is accessed: · navigate to Serial & Network > Authen"ca"on. · check LDAP or LocalLDAP or LDAPLocal or LDAPDownLocal. · enter the Server Address (IP or host name) of the remote Authen!ca!on server. Mul!ple remote servers may be specified in a comma separated list. Each server is tried in succession. · check the Server Protocol checkbox to select if SSL is to be used or enforced for communica!ons with the LDAP server. Console servers running firmware v3.11 and above offer three op!ons for LDAPS (LDAP over SSL): LDAP over SSL preferred will a%empt to use SSL for authen!ca!on. If it fails, it will fall back to LDAP without SSL. LDAP over SSL may fail due to cer!ficate errors or the LDAP server not being contactable on the LDAPS port. LDAP over SSL only. This se$ng will configure the Opengear device to only accept LDAP over SSL. If LDAP over SSL fails you will only be able to log into the console server as root. LDAP (no SSL) only. This se$ng will configure the Opengear device to only accept LDAP without SSL. If LDAP without SSL fails you will only be able to log into the console server as root. · Check the Ignore SSL Cer"ficate Error check box if you wish to ignore SSL cer!ficate errors, allowing LDAP over SSL to work regardless of these errors. This allows you to use any cer!ficate, self-signed or otherwise, on the LDAP server without having to install any cer!ficates on the console server. If this se$ng is not checked, you must install the CA (cer!ficate authority) cer!ficate with which the LDAP server's cer!ficate was signed, onto the console server. For example, the LDAP server is serving with a cer!ficate signed using the cer!ficate myCA.crt. Note: The cer#ficate must be in CRT format and myCA.crt must be installed onto the console server at /etc/config/ldaps_ca.crt. The filename must be ldaps_ca.crt. Copy the file to this loca#on and filename manually using scp or the like. For example: scp /local/path/to/myCA.crt rt root@console_server:/etc/config/ldaps_ca.crt · Enter the Server Password. · Click Apply. LDAP remote authen!ca!on will now be used for all user access to console server and serially or network a%ached devices Opengear User Manual. Page 218. Further informa!on on configuring remote RADIUS servers can be found at the following sites: h%p://ldapman.org/ar!cles/intro_to_ldap.html, h%p://ldapman.org/servers.html, h%p:// linuxplanet.com/linuxplanet/tutorials/5050/1/, and h%p://linuxplanet.com/linuxplanet/ tutorials/5074/4/. 8.1.5. RADIUS & TACACS user configura"on Users may be added to the local console server appliance. If they are not added and they log in via remote AAA, a user will be added for them. This user will not show up in the Opengear configurators unless they are specifically added, at which point they are transformed into a completely local user. The newly added user must authen!cate off of the remote AAA server, and will have no access if it is down. If a local user logs in, they may be authen!cated or authorized from the remote AAA server, depending on the chosen priority of the remote AAA. A local user's authoriza!on is the union of local and remote privileges. Example 1 User Tim is locally added, and has access to ports 1 and 2. He is also defined on a remote TACACS server, which says he has access to ports 3 and 4. Tim may log in with either his local or TACACS password, and will have access to ports 1 through 4. If TACACS is down, he will need to use his local password, and will only be able to access ports 1 and 2. Example 2 User Ben is only defined on the TACACS server, which says he has access to ports 5 and 6. When he a%empts to log in a new user will be created for him, and he will be able to access ports 5 and 6. If the TACACS server is down he will have no access. Example 3 User Paul is defined on a RADIUS server only. He has access to all serial ports and network hosts. Example 4 User Don is locally defined on an appliance using RADIUS for AAA. Even if Don is also defined on the RADIUS server he will only have access to those serial ports and network hosts he has been authorized to use on the appliance. If a no local AAA op!on is selected, then root will s!ll be authen!cated locally. Remote users may be added to the admin group via either RADIUS or TACACS. Users may have a set of authoriza!ons set on the remote TACACS server. Users automa!cally added by RADIUS will have authoriza!on for all resources, whereas those added locally will s!ll need their authoriza!ons specified. LDAP has not been modified, and will s!ll need locally defined users. Note: to interact with RADIUS, TACACS+ and LDAP with console server firmware v2.4.2 and erarlier user accounts on the local console server must also be set up. All resource authoriza#ons must be added to the local appliance. With this release, if remote AAA is selected, it is used for password checking only. Root is always authen#cated locally. Changes to PAM configura#ons will be destroyed next #me the authen#ca#on configurator is run. Opengear User Manual. Page 219. 8.1.6. Group support with remote authen"ca"on All console servers allow remote authen!ca!on via RADIUS, LDAP and TACACS+. With firmware v3.2 and later, RADIUS and LDAP can provide addi!onal restric!ons on user access based on group informa!on or membership. For example, with remote group support, users can belong to a local group that has been setup to have restricted access to serial ports, network hosts and managed devices. Remote authen!ca!on with group support works by matching a local group name with a remote group name provided by the authen!ca!on service. If the list of remote group names returned by the authen!ca!on service matches any local group names, the user is given permissions as configured in the local groups. To enable group support to be used by remote authen!ca!on services: · navigate to Serial & Network > Authen"ca"on. · select the relevant Authen"ca"on Method. · check the Use Remote Groups checkbox. 8.1.7. Remote groups with RADIUS authen"ca"on · Enter the RADIUS Authen"ca"on and Authoriza"on Server Address and Server Password. · Click Apply. · Edit the Radius user's file to include group informa!on and restart the Radius server. When using RADIUS authen!ca!on, group names are provided to the console server using the Framed-Filter-Id a%ribute. This is a standard RADIUS a%ribute, and may be used by other devices that authen!cate via RADIUS. To interoperate with other devices using this field, the group names can be added to the end of any exis!ng content in the a%ribute, in the following format: :group_name=testgroup1,users: This example sets the remote user as a member of testgroup1 and users, if these groups exist on the console server. Groups that do not exist on the console server are ignored. Opengear User Manual. Page 220. When se$ng the Framed-Filter-Id, the system may also remove the leading colon for an empty field. To work around this, add some dummy text to the start of the string. For example: dummy:group_name=testgroup1,users: If no group is specified for a user -- for example AmandaJones -- then the user will have limited console access, with no user interface or serial port access. Default groups available on the console server include admin for administrator access and users for general user access. TomFraser Cleartext-Password := "FraTom70" Framed-Filter-Id=":group_name=admin:" AmandaJones Cleartext-Password := "JonAma83" FredWhite Cleartext-Password := "WhiFre62" Framed-Filter-Id=":group_name=testgroup1,users:" JanetLong Cleartext-Password := "LonJan57" Framed-Filter-Id=":group_name=admin:" Addi!onal local groups such as testgroup1 can be added via Users & Groups > Serial & Network. Opengear User Manual. Page 221. 8.1.8. Remote groups with LDAP authen"ca"on Unlike RADIUS, LDAP has built in support for group provisioning, which makes se$ng up remote groups easier. The console server will retrieve a list of all the remote groups that the user is a direct member of, and compare their names with local groups on the console server. Note: spaces in an LDAP group name will be converted to underscores. For example, in an exis!ng Ac!ve Directory setup, a group of users may be part of the UPS Admin and Router Admin groups. On the console server, these users will be required to have access to a group Router_Admin, with access to port 1 (connected to the router), and another group, UPS_Admin, with access to port 2 (connected to the UPS). Once LDAP is setup, users that are members of each group will have the appropriate permissions to access the router and UPS. Currently, the only LDAP directory service that supports group provisioning is Microso& Ac!ve Directory. Support is planned for OpenLDAP at a later !me. To enable group informa!on to be used with an LDAP server: · Complete the fields for standard LDAP authen!ca!on including LDAP Server Address, Server Password, LDAP Base DN, LDAP Bind DN and LDAP User Name A$ribute. · Enter memberOf for LDAP Group Membership A$ribute as group membership is currently only supported on Ac!ve Directory servers. · If required, enter the group informa!on for LDAP Console Server Group DN, LDAP Administra"on Group DN, or both. A user must be a member of the LDAP Console Server Group DN group to gain access to the console and user interface. For example, the user must be a member of MyGroup on the Ac!ve Server to gain access to the console server. Addi!onally, a user must be a member of the LDAP Administra"on Group DN in order to gain administrator access to the console server. For example, the user must be a member of AdminGroup on the Ac!ve Server to receive administra!on privileges on the console server. Opengear User Manual. Page 222. · Click Apply. · Ensure the LDAP service is opera!onal and group names are correct within the Ac!ve Directory. Note: When you are using remote groups with LDAP remote auth, you need to have corresponding local groups on the console server. Where the LDAP group names can contain upper case and space characters, however, the local group name on the console server must be all lower case and the spaces replaced with underscrores. For example, a remote group on the LDAP server may be My Ldap Access Group. The corresponding local group on the console server must be my_ldap_access_group. The local group on the console server must specify what the group member is granted access to for any group membership to be effec#ve. 8.1.9. Remote groups with TACACS+ authen"ca"on When using TACACS+ authen!ca!on, there are two ways to grant a remotely authen!cated user privileges. The first is to set the priv-lvl and port a%ributes of the raccess service to 12. See chapter 8.2 for more. Addi!onally, or alterna!vely, group names can be provided to the console server using the groupname custom a%ribute of the raccess service. An example Linux tac-plus config snippet might look like: user = myuser { service = raccess { groupname="users" groupname1="routers" groupname2="dracs" } } You may also specify mul!ple groups in one comma-delimited. Fore example groupname="users,routers,dracs" Note: the maximum length of the a"ribute value string is 255 characters. To use an a%ribute name other than "groupname", set the Authen"ca"on > TACACS+ > TACACS Group Membership A%ribute. 8.1.10. Idle "meout You can specify the !me the console server waits before it terminates an idle ssh, pmshell or web connec!on. · Navigate to Serial & Network > Authen"ca"on. Opengear User Manual. Page 223. · set a Web Management Session Timeout in minutes. This specifies the browser console session idle !meout. The default se$ng is 20 minutes. · Set a CLI Management Session Timeout in minutes. This specifies the ssh console session idle !meout. The default se$ng is to never expire. · Set a Console Server Session Timeout in minutes. This specifies the pmshell serial console server session idle !meout. The default se$ng is to never expire. 8.1.11. Kerberos authen"ca"on Kerberos authen!ca!on can be used with UNIX and Windows (Ac!ve Directory) Kerberos servers. This form of authen!ca!on does not provide group informa!on, so a local user with the same username must be created, and permissions set. Note: Kerberos is sensi#ve to #me differences between the Key Distribu#on Center (KDC) authen#ca#on server and the client device. Make sure that NTP is enabled, and the #me zone is set correctly on the console server. When authen!ca!ng against Ac!ve Directory, the Kerberos Realm will be the domain name, and the Master KDC will be the address of the primary domain controller. 8.1.12. Authen"ca"on tes"ng Console servers running firmware V3.5.2u3 or later include the Serial & Network > Authen"ca"on > Authen"ca"on Tes"ng tab This tab enables the connec!on to the remote authen!ca!on server to be tested. 8.2. Pluggable authen"ca"on modules (PAM) Console servers support RADIUS, TACACS+ and LDAP for two-factor authen!ca!on via PAM Opengear User Manual. Page 224. (Pluggable Authen!ca!on Modules). PAM is a flexible mechanism for authen!ca!ng users. Nowadays a number of new ways of authen!ca!ng users have become popular. The challenge is that each !me a new authen!ca!on scheme is developed; it requires all the necessary programs (login, &pd etc.) to be rewri%en to support it. PAM provides a way to develop programs that are independent of authen!ca!on scheme. These programs need `authen!ca!on modules' a%ached to them at run-!me in order to work. Which authen!ca!on module is a%ached is dependent on the local system setup and is at the discre!on of the local Administrator. The console server family supports PAM to which we have added the following modules for remote authen!ca!on: module RADIUS TACACS+ LDAP binary pam_radius_auth pam_tacplus pam_ldap source h%ps://freeradius.org/pam_radius_auth/ h%ps://github.com/jeroennijhof/pam_tacplus h%p://padl.com/OSS/pam_ldap.html Further modules can be added as required. Changes made to files in /etc/config/pam.d/ will persist, even if the authen!ca!on configurator is run. · Users added on demand. When a user a%empts to log in, but does not already have an account on the console server, a new user account will be created. This account will have no rights, and no password set. They will not appear in the Opengear configura!on tools. Automa!cally added accounts will not be able to log in if the remote servers are unavailable · Admin rights granted over AAA. Users may be granted Administrator rights via networked AAA. For TACACS a priv-lvl of 12 or above indicates an administrator. For RADIUS, administrators are indicated via the Framed Filter ID. See the example configura!on files below for example. · Authoriza!on via TACACS, LDAP or RADIUS for using remote groups. See chapter 8.1.6. · Authoriza!on via TACACS for both serial ports and host access. Permission to access resources may be granted via TACACS by indica!ng an Opengear Appliance and a port or networked host the user may access. See the example configura!on files below for example. TACACS example user = tim { service = raccess { priv-lvl = 11 port1 = acm7004/port02 Opengear User Manual. Page 225. } global = cleartext mit } RADIUS example paul Cleartext-Password: = "luap" Service-Type = Framed-User, Fall-Through = No, Framed-Filter-Id =":group_name=admin:" The list of groups may include any number of entries separated by a comma. If the admin group is included, the user will be made an Administrator. If there is already a Framed-Filter-Id, add the list of group_names a&er the exis!ng entries, including the separa!ng colon :. 8.3. SSL cer"ficate The console server uses the Secure Socket Layer (SSL) protocol for encrypted network traffic between itself and a connected user. During connec!on establishment the console server has to expose its iden!ty to the user's browser using a cryptographic cer!ficate. The default cer!ficate that comes with the console server device upon delivery is for tes!ng purpose only and should not be relied on for secured global access. Note: system administrators must not rely on the default cer#ficate as the secured global access mechanism for use through Internet. · Switch to your preferred browser. · enter https://ip-address-or-hostname-of-console-server-here/. Your browser may respond with a message that verifies the security cer!ficate is valid but notes that it is not necessarily verified by a cer!fying authority. · To proceed you need to click yes if you are using Internet Explorer or select accept this cer"ficate permanently (or temporarily) if you are using Mozilla Firefox. · The Management Console login will present. · Enter an Administrator's username and password as normal. Opengear User Manual. Page 226. Note: it is recommended you generate and install a new base64 X.509 cer#ficate that is unique for each par#cular console server. To generate a new base64 X.509 cer!ficate, the console server must be enabled to generate a new cryptographic key and the associated Cer!ficate Signing Request (CSR) that needs to be cer!fied by a Cer!fica!on Authority (CA). A cer!fica!on authority verifies that you are the person who you claim you are, and signs and issues a SSL cer!ficate to you. To create and install a SSL cer!ficate for the console server: · Navigate to System > SSL Cer"ficate. · Fill out the presented fields. Common name: the network name of the console server once it is installed in the network. Usually the fully qualified domain name. It is iden!cal to the name used to access the console server with a web browser (without the "h%p://" prefix). If the name given here and the actual network name differ, the browser will pop up a security warning when the console server is accessed using h%ps. Organiza"onal Unit: this field is used for specifying to which department within an organiza!on the console server belongs. Organiza"on: the name of the organiza!on to which the console server belongs. Locality/City: the city where the organiza!on is located. State/Province: the state or province where the organiza!on is located. Country: the two-le%er ISO code designa!ng the country where the organiza!on is located. For example, DE for Germany and US for the the United States of America. Opengear User Manual. Page 227. Note: the country code must be entered in ALL CAPS. Email: the email address of the person responsible for the console server and its security. Challenge Password: some cer!fica!on authori!es require a challenge password to authorize later changes on the cer!ficate (for example, revoca!on of the cer!ficate). Confirm Challenge Password: confirma!on of the Challenge Password. Key length: this is the length of the generated key in bits. 1024 Bits are supposed to be sufficient for most cases. Longer keys may result in slower response !me of the console server during connec!on establishment. · click Generate CSR. The Cer!ficate Signing Request (CSR) genera!on is ini!ated. · Click Download to copy the CSR to your administra!on machine. · Send the saved CSR string to a Cer!fica!on Authority (CA). for cer!fica!on. You will get the new cer!ficate from the CA a&er a more or less complicated tradi!onal authen!ca!on process (depending on the CA). · Upload the cer!ficate received from your CA to the console server using the Upload bu%on. A&er comple!ng these steps the console server has its own cer!ficate that is used for iden!fying the console server to its users. Note: Informa#on on issuing cer#ficates and configuring HTTPS from the command line can be found in chapter 14. Opengear User Manual. Page 228. 9.Nagios integra!on Nagios is a powerful, highly extensible open source tool for monitoring network hosts and services. The core Nagios so&ware package will typically be installed on a server or virtual server, the central Nagios server. Console servers operate in conjunc!on with a central/upstream Nagios server to provide distribu!ng monitoring of a%ached network hosts and serial devices. They embed the NSCA (Nagios Service Checks Acceptor) and NRPE (Nagios Remote Plug-in Executor) add-ons this allows them to communicate with the central Nagios server, elimina!ng the need for a dedicated slave Nagios server at remote sites. The console server products all support distributed monitoring. Even if distributed monitoring is not required, the Console servers can be deployed locally alongside the Nagios monitoring Opengear User Manual. Page 229. host server, to provide addi!onal diagnos!cs and points of access to managed devices. Note: If you have an exis#ng Nagios deployment, you may wish to use the console server gateways in a distributed monitoring server capacity only. If this case and you are already familiar with Nagios, skip ahead to chapter 9.3. 9.1. Nagios overview Nagios provides central monitoring of the hosts and services in your distributed network. Nagios is freely downloadable, open source so&ware. This sec!on offers a quick background of Nagios and its capabili!es. A complete overview, FAQ and comprehensive documenta!on is available at h%ps://nagios.org/. Nagios forms the core of many leading commercial system management solu!ons such as GroundWork, h%ps://gwos.com/. Nagios does take some !me to install and configure. Once it is up and running, however, it provides an outstanding network monitoring system. With Nagios you can: · display tables showing the status of each monitored server and network service in real !me · use a wide range of freely available plug-ins to make detailed checks of specific services. For example, don't just check a database is accep!ng network connec!ons, check that it can actually validate requests and return real data. · Display warnings and send warning e-mails, pager or SMS alerts when a service failure or degrada!on is detected. · Assign contact groups who are responsible for specific services in specific !me frames. 9.2. Configuring Nagios distributed monitoring To ac!vate the console server Nagios distributed monitoring: Nagios integra!on must be enabled and a path established to the central/upstream Nagios server. If the console server is to periodically report on Nagios monitored services, then the NSCA client embedded in the console server must be configured. The NSCA program enables scheduled check-ins with the remote Nagios server and is used to send passive check results across the network to the remote server. If the Nagios server is to ac!vely request status updates from the console server, then the NRPE server embedded in the console server must be configured. The NRPE server is the Nagios daemon for execu!ng plug-ins on remote hosts. Each of the Serial Ports and each of the Hosts connected to the console server which are to be monitored must have Nagios enabled and any specific Nagios checks configured. Lastly the central/upstream Nagios monitoring host must be configured. 9.2.1. Enable Nagios on the console server · Navigate to System > Nagios. Opengear User Manual. Page 230. · Check Enabled. · Enter the Nagios Host Name the console server will be referred to in the Nagios server. This is generated from the local System Name (System > Administra"on) if unspecified. · In Nagios Host Address, enter the address or hostname the upstream Nagios server uses to reach the console server. This defaults to the 1st network port: Network (1) (System > IP). · In Nagios Server Address enter the IP address or DNS name that the console server will use to reach the upstream Nagios monitoring server. · Check the Disable SDT Nagios Extensions op!on to disable SDT Connector integra!on with your Nagios server at the head end. Only check to run vanilla Nagios monitoring. · If not, enter the IP address or DNS name the SDT Nagios clients will use to reach the console server in SDT Gateway Address. · Check Prefer NRPE to use NRPE when possible (that is, for all communica!on except alerts). When NRPE and NSCA are both enabled, NSCA is the preferred method for communica!ng with the upstream Nagios server. 9.2.2. Enable NRPE monitoring Enabling NRPE allows you to execute plug-ins (such as check_tcp and check_ping) on the remote console server to monitor serial or network a%ached remote servers. Opengear User Manual. Page 231. This will offload CPU load from the upstream Nagios monitoring machine which is especially valuable if you are monitoring hundreds or thousands of hosts. To enable NRPE: · Select System > Nagios. · Check NRPE Enabled. · Enter the details of the user connec!on to the upstream Nagios monitoring server. Refer the sample Nagios configura!on example below for details of configuring specific NRPE checks. By default the console server will accept a connec!on between the upstream Nagios monitoring server and the NRPE server with SSL encryp!on, without SSL, or tunneled through SSH. The security for the connec!on is configured at the Nagios server. 9.2.3. Enable NSCA monitoring NSCA is the mechanism that allows you to send passive check results from the remote console server to the Nagios daemon running on the monitoring server. To enable NSCA: · Navigate to System > Nagios. · Check the NSCA Enabled checkbox. · Select the NSCA Encryp"on to be used from the drop down menu. · Enter an NSCA Secret password. · Specify an NSCA Interval (in minutes). Opengear User Manual. Page 232. For more on configuring specific NSCA checks, see the sample Nagios configura!on below. 9.2.4. Configure selected serial ports for Nagios monitoring The individual serial ports connected to the console server to be monitored must be configured for Nagios checks. See chapter 3.4 for details on enabling Nagios monitoring for Hosts that are network connected to the console server. To enable Nagios to monitor on a device connected to the console server serial port: · navigate to Serial & Network > Serial Port. · click Edit on the serial Port # to be monitored. · check the Enable Nagios checkbox. · specify the Host Name of the device on the upstream server. · check the checkboxes of the Nagios checks to be run on this port. Serial Status monitors the handshaking lines on the serial port. Check Port monitors the data logged for the serial port. Opengear User Manual. Page 233. 9.2.5. Configure selected network ports for Nagios monitoring The individual network hosts connected to the console server to be monitored must also be configured for Nagios checks. · Navigate to Serial & Network > Network Port. · Click Edit on the Network Host to be monitored · Check the Enable Nagios checkbox. · Specify the Host Name of the device as it will appear on the upstream Nagios server. · Click New Check to add a specific check which will be run on this host. · Select Check Permi$ed TCP or Check Permi$ed UDP to monitor a service that you have previously added as a permi%ed service. · Alterna!vely, select Check TCP or Check UDP to specify a service port that you wish to monitor, but do not wish to allow external (SDT Connector) access to. · The Nagios Check nominated as the check-host-alive check is the check used to determine whether the network host itself is up or down. Typically this will be Check Ping, although in some cases the host will be configured not to respond to pings. · You can deselect check-host-alive. If check-host-alive check is de-selected, the host will always be assumed to be up. · If required, customize the selected Nagios Checks to use custom arguments. · Click Apply. Opengear User Manual. Page 234. 9.2.6. Configure the upstream Nagios monitoring host For configuring the upstream server refer to the Nagios documenta!on, at h%ps://nagios.org/ documenta!on/. The sec!on en!tled Distributed Monitoring steps through what you need to do to configure NSCA on the upstream server (under Central Server Configura!on) NRPE Documenta!on has recently been added which steps through configuring NRPE on the upstream server h%p://nagios.sourceforge.net/docs/nrpe/NRPE.pdf At this stage, Nagios at the upstream monitoring server has been configured, and individual serial port and network host connec!ons on the console server configured for Nagios monitoring. If NSCA is enabled, each selected check will be executed once over the period of the check interval. If NRPE is enabled, then the upstream server will be able to request status updates under its own scheduling. 9.3. Advanced distributed monitoring configura"on 9.3.1. Sample Nagios configura"on An example configura!on for Nagios is listed below. It shows how to set up a remote console server to monitor a single host, with both network and serial connec!ons. For each check it has two configura!ons: one for NRPE and one for NSCA. In prac!ce, these would be combined into a single check which used NSCA as a primary method, falling back to NRPE if a check was late. For details see the Nagios documenta!on -- at h%ps://nagios.org/documenta!on/ -- on Service and Host Freshness Checks. ; Host definitions ; ; Opengear console server define host { use host_name alias address } generic-host opengear Console server 192.168.254.147 ; Managed Host define host { use host_name alias address } generic-host server server 192.168.254.227 ; NRPE daemon on gateway define command { command_name command_line check_nrpe_daemon $USER1$/check_nrpe -H \ 192.168.254.147 -p 5666 Opengear User Manual. Page 235. } define service { service_description host_name use check_command } NRPE Daemon opengear generic-service check_nrpe_daemon ; Serial Status define command { command_name command_line } check_serial_status $USER1$/check_nrpe -H \ 192.168.254.147 -p 5666 -c \ check_serial_$HOSTNAME$ define service { service_description host_name use check_command } Serial Status server generic-service check_serial_status define service { service_description host_name use check_command active_checks_enabled passive_checks_enabled } serial-signals-server server generic-service check_serial_status 0 1 define servicedependency { name opengear_nrpe_daemon_dep host_name opengear dependent_host_name server dependent_service_description Serial Status service_description NRPE Daemon execution_failure_criteria w,u,c } ; Port Log define command { command_name command_line } check_port_log $USER1$/check_nrpe -H \ 192.168.254.147 -p 5666 -c \ port_log_$HOSTNAME$ define service { service_description host_name Port Log server Opengear User Manual. Page 236. use check_command } generic-service check_port_log define service { service_description host_name use check_command active_checks_enabled passive_checks_enabled } port-log-server server generic-service check_port_log 0 1 define servicedependency { name opengear_nrpe_daemon_dep host_name opengear dependent_host_name server dependent_service_description Port Log service_description NRPE Daemon execution_failure_criteria w,u,c } ; Ping define command { command_name command_line } check_ping_via_opengear $USER1$/check_nrpe -H \ 192.168.254.147 -p 5666 -c \ host_ping_$HOSTNAME$ define service { service_description host_name use check_command } Host Ping server generic-service check_ping_via_opengear define service { service_description host_name use check_command active_checks_enabled passive_checks_enabled host-ping-server server generic-service check_ping_via_opengear 0 1 } define servicedependency { name opengear_nrpe_daemon_dep host_name opengear dependent_host_name server dependent_service_description Host Ping service_description NRPE Daemon Opengear User Manual. Page 237. execution_failure_criteria } w,u,c ; SSH Port define command { command_name command_line } check_conn_via_opengear $USER1$/check_nrpe -H \ 192.168.254.147 -p 5666 -c \ host_$HOSTNAME$_$ARG1$_$ARG2$ define service { service_description host_name use check_command } SSH Port server generic-service check_conn_via_opengear!tcp!22 define service { service_description host_name use check_command active_checks_enabled passive_checks_enabled } host-port-tcp-22-server ; host-port-<protocol>-<port>-<host> server generic-service check_conn_via_opengear!tcp!22 0 1 define servicedependency { name opengear_nrpe_daemon_dep host_name opengear dependent_host_name server dependent_service_description SSH Port service_description NRPE Daemon execution_failure_criteria w,u,c } 9.3.2. Basic Nagios plug-ins Plug-ins are compiled executables or scripts that can be scheduled to be run on the console server to status check a connected host or service. This status is communicated to the Nagios server which uses the results to monitor the status of the network. Console servers are preconfigured with a selec!on of checks that are part of the Nagios plug-ins package. plug-in descrip"on and notes check_tcp Used to check open ports on network hosts. check_udp Used to check open ports on network hosts. check_ping Used to check network host availability. check_nrpe Used to execute arbitrary plug-ins in other devices. check_serial_signals Used to monitor handshaking lines on serial ports. Opengear-specific. check_port_log Used to monitor the data logged for a serial port. Opengear-specific. Opengear User Manual. Page 238. 9.3.3. Addi"onal plug-ins Addi!onal Nagios plug-ins (listed below) are available for all CM7100-, IM7200- and IM4200series devices. check_apt check_dig check_hpjd check_mrtg check_ntp check_real check_ssmtp check_users check_by_ssh check_clamd check_apt check_dns check_dummy check_fping check_h%p check_imap check_jabber check_mrtgtraf check_nagios check_nntp check_nwstat check_overcr check_ping check_simap check_smtp check_snmp check_swap check_tcp check_!me check_by_ssh check_&p check_ldap check_nntps check_pop check_spop check_udp check_clamd check_game check_load check_nt check_procs check_ssh check_ups These plug-ins from the Nagios plug-ins package can be downloaded from &p:// &p.opengear.com/. There also are bash scripts which can be downloaded and run (primarily check_log.sh). To configure addi!onal checks, the downloaded plug-in program must be saved in the *tp addins directory on the USB flash drive and the downloaded text plug-in file saved in / etc/config/. To enable these addi!onal plug-ins: · navigate to Serial & Network > Network Port. · click Edit for the Network Host to be monitored. · select New Checks. The addi!onal check op!ons will have been included in the updated Nagios Checks list, and you can again customize the arguments. If you need other plug-ins to be loaded into the CM7100, IM7200 or IM4200 firmware: · If the plug-in is a Perl script, it must be rewri%en. The console server does not support Perl at this point. If you do require Perl support, please make a feature request to support@opengear.com. · Individual compiled programs may be generated using gcc for ARM. Again contact support@opengear.com for details. 9.3.4. Number of supported devices Ul!mately the number of devices that can be supported by any par!cular console server is a func!on of the number of checks being made, and how o&en they are performed. Access method will also play a part. The table below shows the performance of three of the console server models (1/2-port, 8-port and 16/48 port): NSCA tests 1 check 100 sequen!al checks no encryp"on 3DES ~ 0.5 sec ~ 0.5 sec 100.0 sec 100.0 sec SSH ~ 0.5 sec 100.0 sec Opengear User Manual. Page 239. 10 sequen!al checks, batched upload 1.5 sec 2.0 sec 1.0 sec 100 sequen!al checks, batched upload 7.0 sec 11.0 sec 6.0 sec NRPE tests no encryp"on 1 check 0.1 sec 10 simultaneous checks 1.0 sec max simultaneous checks before "meouts no encryp"on 1-port and 2-port 30 8-port 30 16-port and 48-port 30 3DES tunneled over SSH 0.3 sec 0.1 sec 3.0 sec 1.3 sec 3DES SSH tunnel 20 25 20 25 25 35 The results were from running tests 5 !mes in succession with no !meouts on any runs. However there are a number of ways to increase the number of checks you can do: Usually when using NRPE checks, an individual request will need to set up and tear down an SSL connec!on. This overhead can be avoided by se$ng up an SSH session to the console server and tunneling the NRPE port. This allows the NRPE daemon to be run securely without SSL encryp!on, as SSH will take care of the security. When the console server submits NSCA results it staggers them over a certain !me period (e.g. 20 checks over 10 minutes will result in two check results every minute). Staggering the results like this means that in the event of a power failure or other incident that causes mul!ple problems, the individual freshness checks will be staggered too. NSCA checks are also batched. So in the previous example the two checks per minute will be sent through in a single transac!on. 9.3.5. Distributed monitoring usage scenarios Below are a number of distributed Nagios monitoring scenarios. Local office In this scenario, the console server is set up to monitor the console of each managed device. It can be configured to make a number of checks, either ac!vely at the Nagios server's request, Opengear User Manual. Page 240. or passively at preset intervals, and submit the results to the Nagios server in a batch. The console server may be augmented at the local office site by one or more Intelligent Power Distribu!on Units (IPDUs) to remotely control the power supply to the managed devices. Remote site In this scenario the console server NRPE server or NSCA client can be configured to make ac!ve checks of configured services and upload to the Nagios server wai!ng passively. It can also be configured to service NRPE commands to perform checks on demand. In this situa!on, the console server will perform checks based on both serial and network access. Remote site with restric"ve firewall In this scenario the role of the console server will vary. One aspect may be to upload check results through NSCA. Opengear User Manual. Page 241. Another may be to provide an SSH tunnel to allow the Nagios server to run NRPE commands. Remote site with no network access In this scenario the console server allows dial-in access for the Nagios server. Periodically, the Nagios server will establish a connec!on to the console server and execute any NRPE commands, before dropping the connec!on. Opengear User Manual. Page 242. 10. System management This chapter documents how the Administrator can perform a range of general console server system administra!on and configura!on tasks such as: · applying So& and Hard Resets to the gateway. · re-flashing the Firmware. · configuring the Date, Time and NTP. · se$ng up Backup of the configura!on files. · delayed configura!on commits. · configuring the console server in FIPS mode. System administra!on and configura!on tasks that are covered elsewhere include · chapter 2.2 rese$ng the system. · chapter 2.3 se$ng the console server's System IP Address. · chapter 2.4 Se$ng the Services permi%ed to access the console server. · chapter 4 Se$ng up OOB Dial-in. · chapter 11 Configuring the Dashboard. Opengear User Manual. Page 243. 10.1. System administra"on & reset The Administrator can reboot or reset the gateway to default se$ngs. To affect a so& reset: · navigate to System > Administra"on · Select Reboot. · click Apply. The console server reboots with all se$ngs (for example, the assigned network IP address) preserved. However this so& reset disconnects all users and ends any SSH sessions that had been established. A so& reset will also be affected when you switch OFF power from the console server, and then switch the power back ON. Note: if you cycle the power and the unit is wri#ng to flash you could corrupt or lose data. The so(ware reboot is the safer op#on. To affect a hard reset or hard erase: · Push the Erase bu%on on the rear panel gently twice within a few seconds period while the unit is powered on.. A ball point pen or bent paper clip is a suitable tool for performing this procedure. Do not use a graphite pencil. This will reset the console server back to its factory default se$ngs and clear the console server's stored configura!on informa!on (for example, the unit's IP address will be reset to 192.168.0.1). You will be prompted to log in and must enter the default administra!on username and password: Username: Password: root default 10.2. Firmware upgrades Before upgrading you should ascertain if you are already running the most current firmware in your Opengear device. Your Opengear device will not allow you to upgrade to the same or an earlier version. · The Firmware version is displayed in the header of each page. · Alternately selec!ng Status > Support Report reports the Firmware Version. Opengear User Manual. Page 244. · To upgrade, download the latest firmware image from &p://&p.opengear.com/ or h%p:// opengear.com/firmware/. For ACM5000 family download acm500x.flash. For ACM5500 family download acm500x.flash. For ACM7000 family download acm700x.flash. For CM7116/7132/7148-2 download cm71xx.flash. For IM4216-34 and IM4208/16/32/48-2 download im42xx.flash. For IM7208/16/32/48-2 download im72xx.flash. · Save the firmware image file on to a system on the same subnet as the Opengear device. · Also download and read the Release Notes file for the latest informa!on. · Select System > Firmware on the system to be upgraded. · Specify the address and name of the downloaded firmware upgrade file, or browse the local subnet and locate the downloaded file. · Click Apply. The Opengear device will undertake a so& reboot and commence upgrading the firmware. This process will take several minutes. · A&er the firmware upgrade has completed, click here to return to the Management Console. Your Opengear device will have retained all its pre-upgrade configura!on informa!on. 10.3. Date & "me configura"on It is important to set the local Date and Time in your Opengear appliance as soon as it is configured. Features such as Syslog and NFS logging use the system !me for !me-stamping log entries, while cer!ficate genera!on depends on a correct Timestamp to check the validity period of the cer!ficate. Your Opengear appliance can synchronize its system !me with a remote Network Time Protocol (NTP) server. NTP uses Coordinated Universal Time (UCT) for all !me synchroniza!ons so it is not affected by different !me zones. However you do need to specify your local !me zone so the system clock shows correct local !me. · Select System > Date & Time. Opengear User Manual. Page 245. · Set your appropriate region in the Time Zone selec!on box and click Set Time. Note: With Version 3.2.0 firmware the Time Zone can also be set to UTC, which replaced Greenwich Mean Time as the World standard for #me in 1986. Configuring NTP ensures the Opengear appliance clock is kept extremely accurate once an Internet connec!on has been established. · Select the Enable NTP checkbox in the Network Time Protocol sec!on of the System > Date & Time page. · Enter the IP address of the remote NTP Server. · If your external NTP server requires authen!ca!on, specify the NTP Authen"ca"on Key and the Key Index to use when authen!ca!ng with the NTP server · Click Apply NTP Se!ngs. If remote NTP is not used, the !me can be set manually: · Enter the Year, Month, Day, Hour and Minute using the Date and Time selec!on boxes · Check Set Time. Opengear appliances have an internal, ba%ery-backed hardware clock. Whether set manually, or set by an NTP server, the hardware clock is automa!cally updated. The clock's ba%ery maintains the !me and date across reboots and when the appliance is powered down. With the NTP peering model, the Opengear appliance can share its !me informa!on with other devices connected to it, so all devices can be !me synchronized. To do this, !ck Enable NTP on the Time and Date page, and ensure that the appropriate networks are selected on the Service Access page. Opengear User Manual. Page 246. 10.4. Backup configura"on It is recommended you back up the console server configura!on whenever you make significant changes (such as adding new Users or Managed Devices) or before performing a firmware upgrade. · Select System > Configura"on Backup or click the Backup icon. Note: configura#on files can also be backed up from the command line (see chapter 13). With all console servers you can save the backup file remotely on your PC and you can restore configura!ons from remote loca!ons: · Navigate to System > Configura"on Backup. · Click the Remote Backup tab. · Click Save Backup in the Remote Backup sec!on. The config backup file -- system-name_date_config.opg -- will be downloaded to your PC and saved in the loca!on you nominate. To restore a remote backup: · Navigate to System > Configura"on Backup. · Click the Remote Backup tab. · Click Browse in the Remote Backup sec!on. · Select the backup file you wish to restore. · Click Restore · Click OK. Note: this will overwrite all the current configura#on se&ngs in your console server. With some console servers you can save the backup file locally onto the USB storage. To do this your console server must support USB and you must have an internal or external USB flash drive installed. Opengear User Manual. Page 247. To backup and restore using USB: · Ensure the USB flash drive is the only USB device a%ached to the console server. · Navigate to System > Configura"on Backup. · Select the Local Backup tab. · click click here to proceed. This will set a Volume Label on the USB storage device. This prepara!on step is only necessary the first !me, and will not affect any other informa!on you have saved onto the USB storage device. However it is recommended that you back up any cri!cal data from the USB storage device before using it with your console server. If there are mul!ple USB devices installed you will be warned to remove them. · To back up to the USB enter a brief Descrip"on of the backup in the Local Backup menu and select Save Backup. · The Local Backup menu will display all the configura!on backup files you have stored onto the USB flash drive. · To restore a backup from the drive, select Restore on the par!cular backup you wish to restore and click Apply. A&er saving a local configura!on backup, you may choose to use it as the alternate default configura!on. When the console server is reset to factory defaults, it will then load your alternate default configura!on instead of its factory se$ngs. To set an alternate default configura!on: · check Load On Erase · click Apply. Note: Before selec#ng Load On Erase ensure you have tested your alternate default configura#on by clicking Restore. If your alternate default configura!on causes the console server to become unbootable, recover your unit to factory se$ngs. If the configura!on is stored on an external USB storage device, unplug the storage device and reset to factory defaults as per chapter 10.1. If the configura!on is stored on an internal USB storage device, reset to factory defaults using a specially-prepared USB storage device. Opengear User Manual. Page 248. This specially-prepared USB storage device: · must be forma%ed with a Windows FAT32/VFAT file system on the first par!!on or the en!re disk. Most USB thumb drives are sold already forma%ed this way. · The file system must have the volume label OPG_DEFAULT. · Insert this USB storage device into an external USB port on the console server and reset to factory defaults as per chapter 10.1. · A&er recovering your console server, ensure the problema!c configura!on is no longer selected for Load On Erase. 10.5. Delayed configura"on commit This mode allows the grouping or queuing of configura!on changes and the simultaneous applica!on of these changes to a specific device. For example, changes to authen!ca!on methods or user accounts may be grouped and run once to minimize system down!me. To enable: · Navigate to System > Administra"on. · Check the Delayed Config Commits checkbox. · Click Apply. The Commit Config icon will present in top right-hand corner of the screen between the Backup and Log Out icons. To queue, then run, configura!on changes: Opengear User Manual. Page 249. · Apply all the required changes to the configura!on. For example, modify user accounts, amend authen!ca!on method, enable OpenVPN tunnel or modify system !me. · Click the Commit Config bu%on. This will generate the System > Commit Configura"on screen displaying all the configurators to be run. · Click Apply. All the configurators in the queue will run. · Alterna!vely, click Cancel. All the queued configura!on changes will be lost. To disable the Delayed Configura!on Commits mode: · uncheck the Delayed Config Commits checkbox under System > Administra"on. · click Apply. · click the Commit Config bu%on in top right-hand corner of the screen the System > Commit Configura"on screen displays. · Click Apply. The systemse#ngs configurator runs. The Commit Config bu%on will no longer be displayed in the top right-hand corner of the screen and configura!ons will no longer be queued. 10.6. FIPS mode Opengear User Manual. Page 250. The ACM7000, ACM5500, ACM5000, CM7100, IM7200 and IM4200 family of advanced console servers all use a FIPS 140-2 validated embedded cryptographic module. Note: The US Na#onal Ins#tute of Standards and Technology (NIST) publishes the FIPS (Federal Informa#on Processing Standard) standards. FIPS 140-1 and FIPS 140-2 are both technical standards and worldwide de-facto standards for cryptographic module implementa#on. They are issued by NIST for use government-wide. NIST develops FIPS when there are government requirements, such as for security and interoperability, and no acceptable industry op#ons. Opengear advanced console servers use an embedded OpenSSL cryptographic module validated to FIPS 140-2 standards and in receipt of Cer#ficate #1051. When configured in FIPs mode, all SSH, HTTPS and SDT Connector access to all services on the console server use the embedded FIPS-compliant module. To connect your browser or client must also be using FIPs-approved cryptographic algorithms or the connec!on will fail. · Select System > Administra"on. · Check FIPS Mode This will enable FIPS mode a&er a safe reboot · Check Reboot to safely reboot the console server. · Click Apply. The console server reboots. It will take several minutes to reconnect as secure browser communica!ons are validated. When reconnected it will display FIPs mode: Enabled in the Management Console banner. To enable FIPS mode from the command line, login and run these commands: config -s config.system.fips=on touch /etc/config/FIPS chmod 444 /etc/config/FIPS flatfsd -b The final command saves to flash and reboots the unit. The unit will take a few minutes to boot into FIPS mode. To disable FIPS mode from the shell, run these commands: config -d config.system.fips rm /etc/config/FIPS flatfsd b Opengear User Manual. Page 251. 11. Status reports This chapter documents the Dashboard feature and the status reports that are available: · Port Access and Ac!ve Users · Sta!s!cs. · Support Reports. · Syslog. · Dashboard. Other status reports that are covered elsewhere include: · chapter 7.1 RPC Status. · chapter 7.2 UPS Status. · chapter 7.3 Environmental Status. 11.1. Port access & ac"ve users The Administrator can see which Users have access privileges with which serial ports: · Select Status > Port Access. The Administrator can also see the current status of Users who have ac!ve sessions on those ports: Opengear User Manual. Page 252. · Select Status > Ac"ve Users. With Firmware V3.11 and later the Status > Ac"ve Users menu has been extended to enable Administrators to selec!vely terminate serial sessions. Connec!on types telnet, SSH, raw TCP and unauthen"cated telnet can be disconnected. However you cannot disconnect an RFC2217 session The root user, or any user in the admin group, can access the Ac"ve Users page, which shows a snapshot of the connected sessions, at the !me indicated by the !mestamp displayed at the top of the page. Note that this page only shows the local console ports, and does not include any cascaded ports. There are Disconnect Sessions bu%ons along the right hand side of the table lis!ng ac!ve users. These bu%ons disconnect all sessions from the Port they correspond to. If the port is not set up in Console Server mode, the user will see a pop up error informing them that they need to configure the port as Console Server mode before they can connect and disconnect. A&er the bu%ons have been pressed, the selected sessions will be disconnected, and the number of disconnect sessions will be displayed to the user. To allow more detailed control of who to disconnect, there is a table at the bo%om of the page with drop down lists for all connected users and all connected ports that allow the user to choose who do disconnect.So if you wish to disconnect the user tester from all ports, choose tester in the Users box, and All ports in the Ports box then click Disconnect Sessions. Note: you can also disconnect serial sessions from the command line using the --disconnect op#on with the pmusers command. 11.2. Sta"s"cs The Sta!s!cs report provides a snapshot of the status, current traffic and other ac!vi!es and opera!ons of your console server. · Select Status > Sta"s"cs. Detailed sta!s!cs reports can be found by selec!ng the various tabs. Opengear User Manual. Page 253. For example if you have an ACM5504-5-G-W-I configured with a wireless LAN connec!on the Wireless screen will display all the locally accessible wireless LANs. You can see the SSID and Encryp!on/Authen!ca!on se$ngs for the desired access point. Also when you have successfully connected the SSID of this access point will then be shown in the Wireless ESSID filed of ra0 (shows above as "" which is not connected). 11.3. Support reports The Support Report provides status informa!on that assists the Opengear technical support team to solve any problems you may experience with your console server. With email support requests, generate a Support Report when the issue is occurring, and a%ach it as text. · Select Status > Support Report. A status snapshot presents. · Save the file as a text file and a%ach it to your support email. Note: For console servers running firmware v3.11 and above, for devices where the serial number can be retrieved, there is now a Feature Set sec#on displaying the serial number. ACM5000, ACM5500, ACM7000, CM7100 and IM7200 can display their serial number. For devices not suppor#ng this feature there is no change to the support report. Opengear User Manual. Page 254. Note: There is also a new cli command on all devices called showserial which does nothing more than return the serial number if it is available or 'No serial number informa#on available'. The command exists on all devices so Lighthouse bulk commands can be run on many console servers and obtain as many serial numbers as possible in one opera#on. 11.4. Syslog The console server's Linux system logger maintains a record of all system messages and errors: · Select Status > Syslog. The syslog record can be redirected to a remote Syslog Server: · Enter the remote Syslog Server Address and Syslog Server Port details. · click Apply. The console also maintains a local Syslog. To view this local Syslog file: · Select Status > Syslog. To find specific informa!on in the local Syslog file, a pa%ern matching filter tool is provided. · Specify the Match Pa%ern that is to be searched for · Click Apply. The Syslog will present with only those entries that include the specified pa%ern. 11.5. Dashboard The Dashboard provides the administrator with a summary of the status of the console server Opengear User Manual. Page 255. and its Managed Devices. Custom dashboards can be configured for each user group. 11.5.1. Configuring the Dashboard Only the root user and users who are members of the admin group can configure and access the dashboard. To configure a custom dashboard: · Select System > Configure Dashboard. · Select the user (or group) you are configuring this custom dashboard layout for. You can configure a custom dashboard for any admin user or for the admin group or you can reconfigure the default dashboard. The Status > Dashboard screen is the first screen displayed when admin users (other than root) log into the console manager. If you log in as john, and john is member of the admin group and there is a dashboard layout configured for john, then you will see the dashboard for john on log-in and each !me you click on the Status > Dashboard menu item. If there is no dashboard layout configured for john but there is an admin group dashboard configured then you will see the admin group dashboard instead. If there is no user-specific dashboard or admin group dashboard configured, the default dashboard is displayed. Note: The root user does not have its own dashboard. The Dashboard displays a configurable number of widgets. These widgets include status for major subsystems such as conma, Auto-Response, Managed Devices and cellular. The admin user can configure which of these widgets is to be displayed where: · Go to the Dashboard layout panel and select which widget is to be displayed in each of the Widget Slots. · Click Apply. Opengear User Manual. Page 256. Note: Dashboard configura#on is stored in /etc/config/config.xml. Each configured dashboard will increase the size of this file. If this file gets too big, you can run out of memory space on the console server. 11.5.2. Crea"ng custom widgets for the Dashboard To run a custom script in a dashboard widget create a file called widget-<name>.sh in the folder /etc/config/scripts/. You can have as many custom dashboard files as you want. Put any code inside this file. When configuring the dashboard, choose widget-<name>.sh from the dropdown list. The dashboard runs and displays the script's output inside the widget. The best way to format the output is to send HTML back to the browser using echo: echo '<table>' You can run any command and its output will be displayed in the widget window directly. Below is an example script. It writes the current date to a file, and then echo's HTML code back to the browser. The HTML code gets an image from a URL and displays it in the widget. #!/bin/sh date >> /tmp/test echo '<table>' echo '<tr><td> This is my custom script running </td></tr>' echo '<tr><td>' echo '<img src="http://vinras.com/images/linux-online-inc.jpg">' echo '</td></tr>' echo '</table>' exit 0 Opengear User Manual. Page 257. 12. Management The console server has a small number of Manage reports and tools that are available to both Administrators and Users: · Access and control authorized devices. · View serial port logs and host logs for those devices. · Use SSH or the Web Terminal to access serially a%ached consoles. · Control of power devices (where authorized). All other Management Console menu items are available to Administrators only. 12.1. Device management Note: The Manage Devices UI has been significantly updated as of firmware version 3.12. To display Managed Devices and their grouped serial, network and power connec!ons: · select Manage > Devices or click the Manage Devices icon in the top right of the UI. · admin-group users are presented with a list of all configured Managed Devices and their cons!tuent connec!ons. user-group users only see the Managed Devices where, for each Related Connec!on, they have been explicitly permi%ed access. The Status column displays the current most salient status for each Related Connec!on (for example, Ac!ve Users for serial connec!ons, and power status for RPC outlet connec!ons) with links to detailed status. Opengear User Manual. Page 258. · The links in the Ac"ons column are used to control the Managed Device (for example, to connect to a console session or power cycle. Power ac!ons are not performed un!l the ac!on has been confirmed via pop-up message.) · alterna!vely, select the Serial tab for an ungrouped view of permi%ed serial port connec!ons for the current user. · An addi!onal Signals column displays the current state of the serial pins. Note: To use the Connect > via SSH links, your computer's opera#ng system must recognize the ssh:// URI scheme and have a protocol handler configured (for example, an SSH client like SecureCRT). 12.2. Port & host logs Administrators and Users can view and download logs of data transferred to and from connected devices. · Select Manage > Port Logs. · Select the serial Port # to be displayed. To display Host logs: · select Manage > Host Logs. · Select the Host to be displayed. Opengear User Manual. Page 259. 12.3. Terminal connec"on There are two methods for accessing the console server command line and devices a%ached to the console server serial ports from a web browser. The Web Terminal service uses AJAX to enable the browser to connect to the console server using HTTP or HTTPS, as a terminal without addi!onal client installa!on on the user's PC. Browser access is available to users who are a member of the admin or users groups. The SDT Connector service launches a pre-installed SDT Connector client on the user's PC to establish SSH access, then uses pre-installed client so&ware on the client PC to connect to the console server. 12.3.1. Web terminal The AJAX based Web Terminal service may be used to access the console server command line or a%ached serial devices. Note: Any communica#on using the Web Terminal service using HTTP is unencrypted and not secure. The Web Terminal connects to the command line or serial device using the same protocol that is being used to browse to the Opengear Management Console. If you browse using an https:// URL (this is the default), the Web Terminal connects using HTTPS. To enable the Web Terminal service for the console server: · Select System > Firewall. · Check Enable Web Terminal. · Click Apply. Administrators can now communicate with the console server shell from their browser. · Select Manage > Terminal to display the Web Terminal from which you can log in to the console server command line. Opengear User Manual. Page 260. To enable the Web Terminal service for each serial port you want to access: · Select Serial & Network > Serial Port. · click Edit. · Ensure the serial port is in Console Server Mode. · Check Web Terminal. · Click Apply. Administrator and Users can communicate directly with serial port a%ached devices from their browser: · Select Manage > Devices. · Select the Serial tab. · Under the Ac"on column, click the Web Terminal icon to display the Web Terminal, connected directly to the a%ached serial device. Note: The Web Terminal feature was introduced in firmware v3.3. Earlier releases had an open source jcterm java terminal applet which could be downloaded into your browser to connect to the console server and a"ached serial port devices. However jcterm had some JRE compa#bility issues and is no longer supported. 12.3.2. SDT connector access Opengear User Manual. Page 261. Administrators and Users can communicate directly with the console server command line and with devices a%ached to the console server serial ports using SDT Connector and their local telnet client. · Select Manage > Terminal. · Click Connect to SDT Connector. This ac!vates the SDT Connector client on the computer you are browsing and loads your local telnet client to connect to the command line or serial port using SSH. Note: SDT Connector must be installed on the computer you are browsing from and the console server must be added as a gateway, as detailed in chapter 5. 12.4. Power management Administrators and Users can access and manage the connected power devices. · Select Manage > Power. This enables the user to Turn On, Turn Off, or Cycle the power on any power outlet on any PDU the user has been given access privileges to. See chapter 7 for details. Opengear User Manual. Page 262. 13. Configura!on from the command line For those who prefer to configure their console server at the Linux command line level, rather than use a browser and the Management Console, this chapter describes using command line access and the config tool to manage the console server, configure the ports and so on. This chapter walks thru command line configura!on to deliver the func!ons provided otherwise using the Management Console GUI. For advanced and custom configura!ons and for details using other tools and commands see chapter 14. When displaying a command, the conven!on used in the rest of this chapter is to use single quotes ('') for user-defined values (for example, descrip!ons and names). Element values without single quotes should be typed exactly as shown. A&er the ini!al sec!on on accessing the config command the menu items in this document follow the same structure as the menu items in the web GUI. 13.1. Accessing config from the command line The console server runs a standard Linux kernel and embeds a suite of open source applica!ons. So if you do not want to use a browser and the Management Console tools, you are free to configure the console server and to manage connected devices from the command line using standard Linux and Busybox commands and applica!ons such as ifconfig, gettyd, stty, powerman, nut etc. However without care these configura!ons may not withstand a power-cycle-reset or reconfigure. So Opengear provides a number of custom command line u!li!es and scripts to make it Opengear User Manual. Page 263. simple to configure the console server and ensure the changes are stored in the console server's flash memory etc. In par!cular the config u!lity allows manipula!on of the system configura!on from the command line. With config a new configura!on can be ac!vated by running the relevant configurator, which performs the ac!on necessary to make the configura!on changes live. To access config from the command line: · Power up the console server and connect the "terminal" device. If you are connec!ng using the serial line, plug a serial cable between the console server local DB-9 console port and terminal device. Configure the serial connec!on of the terminal device you are using to 115200bps, 8 data bits, no parity and one stop bit. If you are connec!ng over the LAN, interconnect the Ethernet ports and direct your terminal emulator program to the IP address of the console server (192.168.0.1 by default). · Log on to the console server by pressing Return a few !mes. The console server will request a username and password. · Enter the username root and the password default. The command line prompt appears: # Note: This chapter is not intended to teach you Linux. We assume you already have a certain level of understanding before you execute kernel-level Linux commands. The config tool config [-ahv] [-d id] [-g id] [-p path] [-r configurator] [-s id=value] [-P id] The config tool is designed to perform mul!ple ac!ons from one command if need be, so if necessary op!ons can be chained together. The config tool allows manipula!on and querying of the system configura!on from the command line. Using config the new configura!on can be ac!vated by running the relevant configurator which performs the ac!on necessary to make the configura!on changes live. The custom user configura!on is saved in the /etc/config/config.xml file. This file is transparently accessed and edited when configuring the device using the Management Console browser GUI. Only the root user can configure from the shell. By default, the config elements are separated by a . character (a full-stop or period). The root of the config tree is called <config>. To address a specific element place a . between each node or branch. For example, to access and display the descrip!on of user1 type: # config -g config.users.user1.description The root node of the config tree is <config>. To display the en!re config tree, type: # config -g config To display the help text for the config command, type: Opengear User Manual. Page 264. # config -h The config applica!on resides in the /bin directory. The environmental variable called PATH contains a route to the /bin directory. This allows a user to simply type config at the command prompt instead of the full /bin/config path. op"ons descrip"on -a --run-all Run all registered configurators. This performs every configura!on synchroniza!on ac!on pushing all changes to the live system -h --help Display a brief usage message. -v --verbose Log extra debug informa!on. -d --del=id Remove the given configura!on element specified by a . separated iden!fier. -g --get=id Display the value of a configura!on element -p --path=file Specify an alternate configura!on file to use. The default file is located at /etc/config/config.xml. -r --run=configurator Run the specified registered configurator. Registered configurators are listed below. -s --set=id=value Change the value of configura!on element specified by a . separated iden!fier. -e --export=file Save ac!ve configura!on to file. -i --import=file Load configura!on from file. -t --test-import=file Pretend to load configura!on from file. -S --separator=char The pa%ern to separate fields with. The default is . -P --password=id Prompt user for a value. Hash the value, then save it in id. The registered configurators are: alerts auth cascade console dhcp dialin eventlog hosts ipaccess ipconfig nagios power serialconfig services slave systemse$ngs !me ups users There are three ways to delete a config element value. The simplest way is use the delete-node script detailed later in chapter 14. You can also assign the config element to "" (null), or delete the en!re config node using -d: # /bin/config -d 'element name' All passwords are saved in plaintext except the user passwords and the system passwords, which are encrypted. The config command does not verify whether the nodes edited/added by the user are valid. This means that any node may be added to the tree. If a user were to run the following command: Opengear User Manual. Page 265. # /bin/config -s config.fruit.apple=sweet the configurator will not complain, but this command is clearly useless. When the configurators are run (to turn the config.xml file into live config) they will simply ignore this <fruit> node. Administrators must make sure of the spelling when typing config commands. Incorrect spelling for a node will not be flagged. Most configura!ons made to the XML file will be immediately ac!ve. To make sure that all configura!on changes are ac!ve, especially when edi!ng user passwords, run all the configurators: # /bin/config -a For informa!on on backing up and restoring the configura!on file see chapter 14. 13.1.1. Serial port configura"on The first set of configura!ons that needs to be made to any serial port are the RS232 common se$ngs. For example to setup serial port 5 to use the following proper!es: Baud Rate Parity Data Bits Stop Bits Label Log level Protocol Flow control 9600 None 8 1 Myport 0 RS232 None To do this use the following commands: # config -s config.ports.port5.speed=9600 # config -s config.ports.port5.parity=None # config -s config.ports.port5.charsize=8 # config -s config.ports.port5.stop=1 # config -s config.ports.port5.label=myport # config -s config.ports.port5.loglevel=0 # config -s config.ports.port5.protocol=RS232 # config -s config.ports.port5.flowcontrol=None The following command will synchronise the live system with the new configura!on: # config -r serialconfig Opengear User Manual. Page 266. property supported values baud rates 50 75 110 134 150 200 300 600 1200 1800 2400 4800 9600 19200 38400 57600 115200 230400 parity values None Odd Even Mark Space data-bits 8 7 6 5 stop-bits flow-control 1 1.5 2 Hardware So&ware None Addi!onally, before any port can func!on properly, the mode of the port needs to be set. Any port can be set to run in one of the five possible modes (see chapter 3 for details): Console Server mode Device mode SDT mode Terminal server mode Serial bridge mode All these modes are mutually exclusive. Console Server mode The command to set the port in portmanager mode: # config -s config.ports.port5.mode=portmanager Opengear User Manual. Page 267. To set the following op!onal config elements for this mode: Data accumula!on period 100 ms Escape character % (default is ~) log level 2 (default is 0) Shell power command menu Enabled RFC2217 access Enabled Limit port to 1 connec!on Enabled SSH access Enabled TCP access Enabled telnet access Disabled Unauthorized telnet access Disabled Run the following commands. # config -s config.ports.port5.delay=100 # config -s config.ports.port5.escapechar=% # config -s config.ports.port5.loglevel=2 # config -s config.ports.port5.powermenu=on # config -s config.ports.port5.rfc2217=on # config -s config.ports.port5.singleconn=on # config -s config.ports.port5.ssh=on # config -s config.ports.port5.tcp=on # config -d config.ports.port5.telnet # config -d config.ports.port5.unauthtel Device mode For a device mode port, set the port type to either ups, rpc, or enviro: # config -s config.ports.port5.device.type=[ups | rpc | enviro] For port 5 as a UPS port: # config -s config.ports.port5.mode=reserved For port 5 as an RPC port: # config -s config.ports.port5.mode=powerman For port 5 as an Environmental port: # config -s config.ports.port5.mode=reserved SDT mode To enable access over SSH to a host connected to serial port 5: # config -s config.ports.port5.mode=sdt # config -s config.ports.port5.sdt.ssh=on To configure a username and password when accessing this port with Username = user1 and Password = secret: # config -s config.ports.port#.sdt.username=user1 # config -s config.ports.port#.sdt.password=secret Opengear User Manual. Page 268. Terminal server mode Enable a TTY login for a local terminal a%ached to serial port 5: # config -s config.ports.port5.mode=terminal # config -s config.ports.port5.terminal=\ [vt220 | vt102 | vt100 | linux | ansi] The default terminal is vt220. Serial bridge mode Create a network connec!on to a remote serial port via RFC-2217 on port 5: # config -s config.ports.port5.mode=bridge Op!onal configura!ons for the network address of RFC-2217 server of 192.168.3.3 and TCP port used by the RFC-2217 service = 2500: # config -s config.ports.port5.bridge.address=192.168.3.3 # config -s config.ports.port5.bridge.port=2500 To enable RFC-2217 access: # config -s config.ports.port5.bridge.rfc2217=on To redirect the serial bridge over an SSH tunnel to the server: # config -s config.ports.port5.bridge.ssh.enabled=on Syslog se!ngs Addi!onally, the global system log se$ngs can be set for any specific port, in any mode: # config -s config.ports.port#.syslog.facility='facility' # config -s config.ports.port#.syslog.priority='priority' argument facility supported values Default local 0-7 auth authpriv cron daemon &p kern lpr mail news user uucp Opengear User Manual. Page 269. priority Default warning no!ce Info error emergency debug cri!cal alert 13.1.2. Adding and removing users First, determine the total number of exis!ng Users: # config -g config.users.total This command should display config.users.total 1. Note: if you see config.users.total this means you have 0 Users configured. Your new User will be the exis!ng total plus 1. So if the previous command gave you 0 then you start with user number 1, if you already have 1 user your new user will be number 2 etc. Assuming the previous command did return config.users.total 1., to add a user with Username=John, Password=secret and Descrip!on=mySecondUser issue the commands: # config -s config.users.total=2 # config -s config.users.user2.username=John # config -s config.users.user2.description=mySecondUser # config -P config.users.user2.password Note: the -P parameter will prompt the user for a password, and encrypt it. In fact, the value of any config element can be encrypted using the -P parameter, but only encrypted user passwords and system passwords are supported. If any other element value were to be encrypted, the value will become inaccessible and will have to be re-set. To add this user to specific groups (admin/users): # config -s config.users.user2.groups.group1='groupname' # config -s config.users.user2.groups.group2='groupname2' # [etc...] To give this user access to a specific port: # config -s config.users.user2.port1=on # config -s config.users.user2.port2=on # config -s config.users.user2.port5=on # [etc...] To remove port access: # config -s config.users.user2.port1='' Note: the port1 value is le( blank. Opengear User Manual. Page 270. or simply: # config -d config.users.user2.port1 The port number can be anything from 1 to 48, depending on the available ports on the specific console server. For example, assume we have an RPC device connected to port 1 on the console server and the RPC is configured. To give this user access to RPC outlet number 3 on the RPC device, run the 2 commands below: # config -s config.ports.port1.power.outlet3.users.user2=John # config -s config.ports.port1.power.outlet3.users.total=2 The last command sets the total number of users with access to this outlet. If more users are given access, increment config.ports.port1.power.outlet3.users.total accordingly. To give this user access to network host 5 (assuming the host is configured): # config -s config.sdt.hosts.host5.users.user1=John # config -s config.sdt.hosts.host5.users.total=1 The last command sets the total number of users having access to host. To give another user called Peter access to the same host: # config -s config.sdt.hosts.host5.users.user2=Peter # config -s config.sdt.hosts.host5.users.total=2 The last command sets the total number of users having access to host. To edit any of the user element values, use the same approach as when adding user elements. That is, use the -s parameter. If any of the config elements do not exist, they will automa!cally be created. To delete the user called John, use the delete-node script: # ./delete-node config.users.user2 The following command will synchronize the live system with the new configura!on: # config -r users 13.1.3. Adding and removing user groups The console server is configured with a few default user groups (only two of these groups are visible in the Management Console GUI). To find out how many groups are already present: # config -g config.groups.total Assume this value is six. Make sure to number any new groups you create from seven onwards. To add a custom group to the configura!on with Group name=Group7, Group descrip!on=MyGroup and Port access= 1,5 issue the commands: # config -s config.groups.group7.name=Group7 Opengear User Manual. Page 271. # config -s config.groups.group7.description=MyGroup # config -s config.groups.total=7 # config -s config.groups.group7.port1=on # config -s config.groups.group7.port5=on Assume we have an RPC device connected to port 1 on the console server, and the RPC is configured. To give this group access to RPC outlet number 3 on the RPC device, run the two commands below: # config -s config.ports.port1.power.outlet3.groups.group1=Group7 # config -s config.ports.port1.power.outlet3.groups.total=1 The second command sets the total number of groups that have access to this outlet. If more groups are given access to this power outlet, then increment the config.ports.port1.power.outlet3.groups.total element accordingly. To give this group access to network host 5: # config -s config.sdt.hosts.host5.groups.group1=Group7 # config -s config.sdt.hosts.host5.groups.total=1 The second command sets the total number of groups with access to host. To give another group called Group8 access to the same host: # config -s config.sdt.hosts.host5.groups.group2=Group8 # config -s config.sdt.hosts.host5.groups.total=2 The second command sets the total number of groups with access to host. To delete the group called Group7, use the following command: # rmuser Group7 Note: the rmuser script is a generic script to remove any config element from config.xml correctly. However, any dependencies or references to this group will not be affected. Only the group details are deleted. The administrator is responsible for going through config.xml and removing group dependencies and references manually, specifically if the group had access to a host or RPC device. The following command will synchronize the live system with the new configura!on: # config -a 13.1.4. Authen"ca"on To change the type of authen!ca!on for the console server: # config -s config.auth.type='authtype' `authtype' can be: Local LocalTACACS TACACS TACACSLocal TACACSDownLocal Opengear User Manual. Page 272. LocalRADIUS RADIUS RADIUSLocal RADIUSDownLocal LocalLDAP LDAP LDAPLocal LDAPDownLocal To configure TACACS authen!ca!on: # config -s config.auth.tacacs.auth_server='comma-separated-list' comma-separated-list is a list of remote authen!c!on and authoriza!on servers. # config -s config.auth.tacacs.acct_server='comma-separated-list' # config -s config.auth.tacacs.password='password' comma-separated-list is a list of remote accoun!ng servers. If unset, the Authen!ca!on and Authoriza!on Server Address will be used. To configure RADIUS authen!ca!on: # config -s config.auth.radius.auth_server='comma-separated-list' # config -s config.auth.radius.acct_server='comma-separated-list' # config -s config.auth.radius.password='password' In the first command, comma-separated-list is a list of remote authen!c!on and authoriza!on servers. In the second command, comma-separated-list is a list of remote accoun!ng servers. If unset, Authen!ca!on and Authoriza!on Server Address will be used. To configure LDAP authen!ca!on: # config -s config.auth.ldap.server='comma separated list' # config -s config.auth.ldap.basedn='name' # config -s config.auth.ldap.binddn='name' # config -s config.auth.radius.password='password' In the first command, comma-separated-list is a list of remote servers In the second command name is the dis!nguished name of the search base. For example: dc=my-company,dc=com. In the third command name is the dis!nguished name to bind to the server with. The default is to bind anonymously. The following command will synchronize the live system with the new configura!on: # config -r auth 13.1.5. Network hosts To determine the total number of currently configured hosts: # config -g config.sdt.hosts.total Opengear User Manual. Page 273. Assume the value returned is 3. If you add another host, increment the total number of hosts from 3 to 4: # config -s config.sdt.hosts.total=4 If the output is config.sdt.hosts.total, 0 hosts are configured. Add power device host To add a UPS/RPC network host with the following details: se&ng value IP address or DNS name 192.168.2.5 Host name Descrip!on remoteUPS UPSroom3 Type Allowed services UPS ssh port 22 and h%ps port 443 Log level for services 0 Issue the following commands: # config -s config.sdt.hosts.host4.address=192.168.2.5 # config -s config.sdt.hosts.host4.name=remoteUPS # config -s config.sdt.hosts.host4.description=UPSroom3 # config -s config.sdt.hosts.host4.device.type=ups # config -s config.sdt.hosts.host4.tcpports.tcpport1=22 # config -s config.sdt.hosts.host4.tcpports.tcpport1.loglevel=0 # config -s config.sdt.hosts.host4.udpports.udpport2=443 # config -s config.sdt.hosts.host4.udpports.udpport2.loglevel=0 loglevel can have a value of 0 or 1. The default services that should be configured are: 22/tcp (ssh), 23/tcp (telnet), 80/tcp (h%p), 443/tcp (h%ps), 1494/tcp (ica), 3389/tcp (rdp), 5900/tcp (vnc). Add other network host To add any other type of network host with the following details: se&ng value IP address or DNS name 192.168.3.10 Host name OfficePC Descrip!on MyPC Allowed services ssh port 22 and h%ps port 443 Log level for services 1 Issue the commands below. If the Host is not a PDU or UPS power device or a server with IPMI power control then leave the device type blank: # config -s config.sdt.hosts.host4.address=192.168.3.10 # config -s config.sdt.hosts.host4.description=MyPC # config -s config.sdt.hosts.host4.name=OfficePC # config -s config.sdt.hosts.host4.device.type='' # config -s config.sdt.hosts.host4.tcpports.tcpport1=22 Opengear User Manual. Page 274. # config -s config.sdt.hosts.host4.tcpports.tcpport1.loglevel=1 # config -s config.sdt.hosts.host4.udpports.tcppport2=443 # config -s config.sdt.hosts.host4.udpports.tcpport2.loglevel=1 Note: type should be le( blank. If you want to add the new host as a managed device, make sure to use the current total number of managed devices + 1, for the new device number. To get the current number of managed devices: # config -g config.devices.total Assuming we already have one managed device, our new device will be device 2. Issue the following commands: # config -s config. devices.device2.connections.connection1.name=192.168.3.10 # config -s config. devices.device2.connections.connection1.type=Host # config -s config. devices.device2.name=OfficePC # config -s config. devices.device2.description=MyPC # config -s config.devices.total=2 The following command will synchronize the live system with the new configura!on: # config -hosts 13.1.6. Trusted networks You can further restrict remote access to serial ports based on the source IP address. To configure this via the command line you need to do the following: Determine the total number of exis!ng trusted network rules (if you have no exis!ng rules) you can assume this is 0 # config -g config.portaccess.total This command should display config.portaccess.total 1 If you see config.portaccess.total you have 0 rules configured. Your new rule will be the exis!ng total plus 1. If the previous command gave you 0 start with rule number 1. If you already have 1 rule your new rule will be number 2. And so on. Assuming you have a previous rule in place, if you want to restrict access to serial port 5 to computers from a single class C network (for example, 192.168.5.0) issue the following commands to add a trusted network: # config -s config.portaccess.rule2.address=192.168.5.0 # config -s "config.portaccess.rule2.description=foo bar" # config -s config.portaccess.rule2.netmask=255.255.255.0 # config -s config.portaccess.rule2.port5=on # config -s config.portaccess.total=2 Opengear User Manual. Page 275. The following command will synchronize the live system with the new configura!on: # config -r serialconfig 13.1.7. Cascaded ports To add a new slave device with the following se$ngs: se&ng value IP address or DNS name 192.168.0.153 Descrip!on Office 42 Label cm7116-5 Number of ports 16 Issue the following commands: # config -s config.cascade.slaves.slave1.address=192.168.0.153 # config -s "config.cascade.slaves.slave1.description=Office 42" # config -s config.cascade.slaves.slave1.label=cm7116-5 # config -s config.cascade.slaves.slave1.ports=16 The total number of slaves must also be incremented. If this is the first slave being added, type: # config -s config.cascade.slaves.total=1 Increment this value when adding more slaves. Note: if a slave is added using the CLI, the master SSH public key will need to be manually copied to every slave device before cascaded ports will work (see chapter 3). The following command will synchronize the live system with the new configura!on: # config -r cascade 13.1.8. UPS connec"ons Managed UPSes Before adding a managed UPS, make sure that at least 1 port has been configured to run in 'device mode', and that the device is set to 'ups'. To add a managed UPS with the following values: se&ng Connected via UPS name Descrip!on Username to connect to UPS Password to connect to UPS shutdown order Driver Driver op!on value Port 1 My UPS Room 5 UPS user2 A-secret-for-2. 2 (0 shuts down first genericups op!on Opengear User Manual. Page 276. Driver argument Logging Log interval Run script when power is cri!cal Run the following commands argument Enabled 2 minutes Enabled # config -s config.ups.monitors.monitor1.port=/dev/port01 # config -s "config.ups.monitors.monitor1.name=My UPS" # config -s "config.ups.monitors.monitor1.description=Room 5 UPS" # config -s config.ups.monitors.monitor1.username=user2 # config -s config.ups.monitors.monitor1.password=A-secret-for-2. # config -s config.ups.monitors.monitor1.sdorder=2 # config -s config.ups.monitors.monitor1.driver=genericups # config -s config.ups.monitors.monitor1.options.option1.opt=option # config -s config.ups.monitors.monitor1.options.option1.arg=argument # config -s config.ups.monitors.monitor1.options.total=1 # config -s config.ups.monitors.monitor1.log.enabled=on # config -s config.ups.monitors.monitor1.log.interval=2 # config -s config.ups.monitors.monitor1.script.enabled=on With regards the first command above, if the port number is higher than 9 (eg port 13) enter the command as follows: # config -s config.ups.monitors.monitor1.port=/dev/port13 Also, make sure to increment the total monitors: # config -s config.ups.monitors.total=1 Assuming there are already 2 managed devices configured, the 5 commands below will add the UPS to Managed Devices. # config -s "config.devices.device3.connections.connection1.name=My UPS" # config -s "config.devices.device3.connections.connection1.type=UPS Unit" # config -s "config.devices.device3.name=My UPS" # config -s "config.devices.device3.description=Room 5 UPS" # config -s config.devices.total=3 To delete this managed UPS: # config -d config.ups.monitors.monitor1 Note: decrement monitors.total when dele#ng a managed UPS. Remote UPSes To add a remote UPS with the following details (assuming this is our first remote UPS): se&ng UPS name value oldUPS Opengear User Manual. Page 277. Descrip!on Address Log status Log rate Run shutdown script Room 2 UPS 192.168.50.50 Disabled 240 seconds Enabled # config -s config.ups.remotes.remote1.name=oldUPS # config -s "config.ups.remotes.remote1.description=Room 2 UPS" # config -s config.ups.remotes.remote1.address=192.168.50.50 # config -d config.ups.remotes.remote1.log.enabled # config -s config.ups.remotes.remote1.log.interval=240 # config -s config.ups.remotes.remote1.script.enabled=on # config -s config.ups.remotes.total=1 The following command will synchronize the live system with the new configura!on: # config -a 13.1.9. RPC connec"ons You can add an RPC connec!on from the command line but it is not recommended because of dependency issues. Before adding an RPC, the Management Console GUI code makes sure that at least 1 port has been configured to run in device mode, and that the device is set to rpc. The CLI-based approach does not do this. To add an RPC with the following values: se&ng RPC type Connected via UPS name Descrip!on Login name for device Login password for device SNMP community Logging Log interval Number of power outlets Run the following commands: value APC 7900 Port 2 MyRPC Room 5 RPC rpclogin A-secret-for-2. v1 or v2c enabled 600 seconds 4 # config -s config.ports.port2.power.type=APC 7900 # config -s config.ports.port2.power.name=MyRPC # config -s "config.ports.port2.power.description=Room 5 RPC" # config -s config.ports.port2.power.username=rpclogin # config -s config.ports.port2.power.password=A-secret-for-2. # config -s config.ports.port2.power.snmp.community=v1 # config -s config.ports.port2.power.log.enabled=on # config -s config.ports.port2.power.log.interval=600 Opengear User Manual. Page 278. # config -s config.ports.port2.power.outlets=4 The following five commands are used by the Management Console to add the RPC to Managed Devices: # config -s config.devices.device3.connections.connection1.name=myRPC # config -s "config.devices.device3.connections.connection1.type=RPC Unit" # config -s config.devices.device3.name=myRPC # config -s "config.devices.device3.description=Room 5 RPC" # config -s config.devices.total=3 The following command will synchronize the live system with the new configura!on: # config -a 13.1.10.Environmental To configure an environmental monitor with the following details: se&ng value Monitor name Envi4 Monitor descrip!on Room 5 monitor Temperature offset 2 Humidity offset 5 Enable alarm 1? yes Alarm 1 label door alarm Enable alarm 2? yes Alarm 2 label window alarm Run the following commands: # config -s config.ports.port3.enviro.name=Envi4 # config -s "config.ports.port3.enviro.description=Room 5 monitor" # config -s config.ports.port3.enviro.offsets.temp=2 # config -s config.ports.port3.enviro.offsets.humid=5 # config -s config.ports.port3.enviro.alarms.alarm1.alarmstate=on # config -s config.ports.port3.enviro.alarms.alarm1.label=door alarm # config -s config.ports.port3.enviro.alarms.alarm2.alarmstate=on # config -s config.ports.port3.enviro.alarms.alarm2.label=window alarm # config -s config.ports.port3.enviro.alarms.total=2 # config -s config.ports.port3.enviro.log.enabled=on # config -s config.ports.port3.enviro.log.interval=120 It is important to assign alarms.total=2 even if they are off. To get the total number of managed devices: Opengear User Manual. Page 279. # config -g config.devices.total Use the returned total +1 for the new device when adding this environmental monitor to Managed devices as per the following: # config -s config. devices.device5.connections.connection1.name=Envi4 # config -s "config. devices.device5.connections.connection1.type=EMD Unit" # config -s config. devices.device5.name=Envi4 # config -s "config. devices.device5.description=Room 5 monitor" # config -s config.devices.total=5 The following command will synchronize the live system with the new configura!on: # config -a 13.1.11.Managed devices To add a managed device: (see chapter 7 for more): # config -s "config.devices.device8.name=8" # config -s "config.devices.device8.description=the-8th-device" # config -s "config.devices.device8.connections.connection1.name=8" # config -s config.devices.device8.connections.connection1.type=type # config -s config.devices.total=8 type can be serial, Host, UPS, or RPC. To delete the above managed device: # config -d config.devices.device8 Note: the config.devices.total total must also be decremented when dele#ng a managed device. The following command will synchronize the live system with the new configura!on: # config -a 13.1.12.Port log To configure serial/network port logging: # config -s config.eventlog.server.address=remote-server-ip # config -s config.eventlog.server.logfacility=facility # config -s config.eventlog.server.logpriority=priority facility and priority can take a specific range of values: Opengear User Manual. Page 280. variable allowed values facility Daemon Local 0-7 Authen!ca!on Kernel User Syslog Mail News UUCP priority Info Alert Cri!cal Debug Emergency Error No!ce Warning Assume the remote log server needs a username name1 and password A-secret-for-2. # config -s config.eventlog.server.username=name1 # config -s config.eventlog.server.password=A-secret-for-2. To set the remote path as /opengear/logs to save logged data: # config -s config.eventlog.server.path=/opengear/logs # config -s config.eventlog.server.type=[none|syslog|nfs|cifs|usb] If the server type is set to usb, none of the other values need to be set. The mount point for storing on a remote USB device is /var/run/portmanager/logdir. The following command will synchronize the live system with the new configura!on: # config -a 13.1.13.Alerts You can add an email, SNMP or NAGIOS alert by following the steps below. The general se!ng for all alerts Assume this is our second alert, and we want to send email alerts to john@opengear.com and sms alerts to peter@opengear.com: # config -s config.alerts.alert2.description=MySecondAlert # config -s config.alerts.alert2.email=john@opengear.com # config -s config.alerts.alert2.email2=peter@opengear.com To use NAGIOS to no!fy of this alert # config -s config.alerts.alert2.nsca.enabled=on To use SNMP to no!fy of this alert Opengear User Manual. Page 281. # config -s config.alerts.alert2.snmp.enabled=on To increment the total alerts: # config -s config.alerts.total=2 Below are the specific se$ngs depending on the type of alert required. Connec"on alert To trigger an alert when a user connects to serial port 5 or network host 3: # config -s config.alerts.alert2.host3=hostname # config -s config.alerts.alert2.port5=on # config -s config.alerts.alert2.sensor=temp # config -s config.alerts.alert2.signal=DSR # config -s config.alerts.alert2.type=login Signal alert To trigger an alert when a signal changes state on port 1: # config -s config.alerts.alert2.port1=on # config -s config.alerts.alert2.sensor=temp # config -s config.alerts.alert2.signal=[DSR | DCD | CTS] # config -s config.alerts.alert2.type=signal Pa%ern match alert To trigger an alert if the regular expression .*0.0% id is found in serial port 10's character stream. # config -s "config.alerts.alert2.pattern=.*0.0% id" # config -s config.alerts.alert2.port10=on # config -s config.alerts.alert2.sensor=temp # config -s config.alerts.alert2.signal=DSR # config -s config.alerts.alert2.type=pattern UPS power status alert To trigger an alert when myUPS (on localhost) or thatUPS (on remote host 192.168.0.50) power status changes between on line, on ba%ery and low ba%ery. # config -s config.alerts.alert2.sensor=temp # config -s config.alerts.alert2.signal=DSR # config -s config.alerts.alert2.type=ups # config -s config.alerts.alert2.ups1=myUPS@localhost # config -s config.alerts.alert2.ups2=thatUPS@192.168.0.50 Environmental and power sensor alert # config -s config.alerts.alert2.enviro.high.critical=criticalvalue # config -s config.alerts.alert2.enviro.high.warning=warning-value # config -s config.alerts.alert2.enviro.hysteresis=value # config -s config.alerts.alert2.enviro.low.critical=criticalvalue Opengear User Manual. Page 282. # config -s config.alerts.alert2.enviro.low.warning=warning-value # config -s config.alerts.alert2.enviro1=Enviro-sensor-name # config -s config.alerts.alert2.outlet#=RPCname.outlet# # config -s config.alerts.alert2.rpc#=RPC-name # config -s config.alerts.alert2.sensor=[temp|humid|load|charge] # config -s config.alerts.alert2.signal=DSR # config -s config.alerts.alert2.type=enviro # config -s config.alerts.alert2.ups1=UPSname@hostname alert2.outlet# increments sequen!ally with each added outlet. The second outlet# refers to the specific RPC power outlets. Example 1: to configure a temperature sensor alert for a sensor called SensorInRoom42. # config -s config.alerts.alert2.sensor=temp # config -s config.alerts.alert2.enviro.high.critical=60 # config -s config.alerts.alert2.enviro.high.warning=50 # config -s config.alerts.alert2.enviro.hysteresis=2 # config -s config.alerts.alert2.enviro.low.critical=5 # config -s config.alerts.alert2.enviro.low.warning=10 # config -s config.alerts.alert2.enviro1=SensorInRoom42 # config -s config.alerts.alert2.signal=DSR # config -s config.alerts.alert2.type=enviro Example2: to configure a load sensor alert for outlets 2 and 4 for an RPC called RPCInRoom20: # config -s config.alerts.alert2.outlet1=RPCInRoom20.outlet2 # config -s config.alerts.alert2.outlet2=RPCInRoom20.outlet4 # config -s config.alerts.alert2.enviro.high.critical=300 # config -s config.alerts.alert2.enviro.high.warning=280 # config -s config.alerts.alert2.enviro.hysteresis=20 # config -s config.alerts.alert2.enviro.low.critical=50 # config -s config.alerts.alert2.enviro.low.warning=70 # config -s config.alerts.alert2.rpc1=RPCInRoom20 # config -s config.alerts.alert2.sensor=load # config -s config.alerts.alert2.signal=DSR # config -s config.alerts.alert2.type=enviro Alarm sensor alert The commands below set an alert for doorAlarm and windowAlarm, two alarms connected to an environmental sensor called SensorInRoom3. Both alarms are disabled on Mondays from 08:15 to 14:30. # config -s config.alerts.alert2.alarm1=SensorInRoom3.alarm1 (doorAlarm) # config -s config.alerts.alert2.alarm1=SensorInRoom3.alarm2 (windowAlarm) # config -s config.alerts.alert2.alarmrange.mon.from.hour=8 # config -s config.alerts.alert2.alarmrange.mon.from.min=15 # config -s config.alerts.alert2.alarmrange.mon.until.hour=14 # config -s config.alerts.alert2.alarmrange.mon.until.min=30 # config -s config.alerts.alert2.description='description' Opengear User Manual. Page 283. # config -s config.alerts.alert2.sensor=temp # config -s config.alerts.alert2.signal=DSR # config -s config.alerts.alert2.type=alarm To enable an alarm for the en!re day: # config -s config.alerts.alert2.alarmrange.mon.from.hour=0 # config -s config.alerts.alert2.alarmrange.mon.from.min=0 # config -s config.alerts.alert2.alarmrange.mon.until.hour=0 # config -s config.alerts.alert2.alarmrange.mon.until.min=0 The following command will synchronize the live system with the new configura!on: # config -r alerts 13.1.14.SMTP & SMS To set-up an SMTP mail or SMS server with the following details: smtp or sms server se&ng Outgoing server address Secure conec!on type Sender Server username Server password Subject line Run the following commands: value mail.opengear.com SSL john@opengear.com john A-li%le-secret-for-2. SMTP alerts # config -s config.system.smtp.server=mail.opengear.com # config -s config.system.smtp.encryption=SSL # config -s config.system.smtp.sender=John@opengear.com # config -s config.system.smtp.username=john # config -s config.system.smtp.password=A-little-secret-for-2. # config -s config.system.smtp.subject=SMTP alerts To set-up an SMTP SMS server with the same details as above: # config -s config.system.smtp.server2=mail.opengear.com # config -s config.system.smtp.encryption2=SSL # config -s config.system.smtp.sender2=john@opengear.com # config -s config.system.smtp.username2=john # config -s config.system.smtp.password2=A-little-secret-for-2. # config -s config.system.smtp.subject2=SMTP alerts In both setups, the value for encryption can be SSL, TLS or None. The following command will synchronize the live system with the new configura!on: # config -a 13.1.15.SNMP To set-up the SNMP agent on the device: Opengear User Manual. Page 284. # config -s config.system.snmp.protocol=[UDP | TCP] # config -s config.system.snmp.trapport=port-number # config -s config.system.snmp.address=NMS-IP-network-address # config -s config.system.snmp.community=community-name # config -s config.system.snmp.engineid=ID # config -s config.system.snmp.username=username # config -s config.system.snmp.password=password # config -s config.system.snmp.version=[1 | 2c | 3] The default port number is 162. The community value can only be set on v1 and v2c. The engineid, username, and password values can only be set on v3. The following command will synchronize the live system with the new configura!on: # config -r auth 13.1.16.Administra"on To change the administra!on se$ngs to: system se&ng System name System password (root account password) Descrip!on Run the following commands: value og.example.com A-simple-li%le-secret-for-2. Device in office 2 # config -s config.system.name=og.example.com: # config -P config.users.user1.password # config -s "config.system.location="Device in office 2" The second command has an interac!ve aspect. The -P parameter will prompt the user for a password. Enter the desired string and press Return: config will accept and encrypt the string. Note: any config element value can be encrypted using the -P parameter. Only encrypted user passwords and system passwords are supported, however. If any other element value is encrypted, the value becomes inaccessible and will have to be re-set. An alterna!ve to the second command above is: # /etc/scripts/user-mod -P root The following command will synchronize the live system with the new configura!on: # config -r auth 13.1.17.IP se&ngs To configure the primary network interface with the following sta!c se$ngs: Opengear User Manual. Page 285. Network interface se&ng value IP address 192.168.0.23 Netmask 255.255.255.0 Default gateway 192.168.0.1 DNS server 1 192.168.0.1 DNS server 2 192.168.0.2 # config -s config.interfaces.wan.address=192.168.0.23 # config -s config.interfaces.wan.netmask=255.255.255.0 # config -s config.interfaces.wan.gateway=192.168.0.1 # config -s config.interfaces.wan.dns1=192.168.0.1 # config -s config.interfaces.wan.dns2=192.168.0.2 # config -s config.interfaces.wan.mode=static # config -s config.interfaces.wan.media=<value> In the last command, the available op!ons for <value> are: Auto, 100baseTx-FD, 100baseTxHD, 10baseT-HD, and 10baseT-FD. To configure the management LAN interface, use the same commands as above but replace config.interfaces.wan with config.interfaces.lan. To enable bridging between all interfaces: # config -s config.system.bridge.enabled=on To enable IPv6 for all interfaces: # config -s config.system.ipv6.enabled=on To enable the management LAN interface run the following command: # config -d config.interfaces.lan.disabled # config -r ipconfig Note: not all devices have a management LAN interface. To configure a failover device in case of an outage: # config -s config.interfaces.wan.failover.address1=ip-address # config -s config.interfaces.wan.failover.address2=ip-address # config -s config.interfaces.wan.failover.interface=<interface> In the last command, the available op!ons for <interface> are: eth1, console, modem Network interfaces can also be configured automa!cally: # config -s config.interfaces.wan.mode=dhcp # config -s config.interfaces.lan.mode=dhcp Either of the following commands will synchronize the live system with the new configura!on: # /bin/config -run=ipconfig # config -r ipconfig Opengear User Manual. Page 286. 13.1.18.Date & "me se&ngs To enable NTP using a server at pool.ntp.org issue the following commands: # config -s config.ntp.enabled=on # config -s config.ntp.server=pool.ntp.org Alterna!vely, you can manually change the clock se$ngs. To change running system !me: # date MMDDhhmm[CC]YY.ss # /bin/hwclock --systohc The first command sets a new system !me. Note: the date command uses a US-style order with month (MM) listed before day (DD). Also, although the thousands and hundreds column in the Gregorian Year are theore#cally op#onal, it is strongly recommended that these values be set explicitly. The second command saves this new system !me to the hardware clock. Alterna!vely, to first change the hardware clock and then set the system !me to the newly set hardware !me : # /bin/hwclock --set --date=MMDDhhmm[CC]YY.ss # /bin/hwclock --hctosys To change the !mezone: # config -s config.system.timezone=US/Eastern The following command will synchronize the live system with the new configura!on: # config -r time 13.1.19.Dial-in se&ngs To enable dial-in access on the DB9 serial port from the command line with the following a%ributes: se&ng Local IP address Remote IP address Authen!ca!on type Serial port baud rate Serial port flow control Custom modem ini!aliza!on Callback phone number User to dial as Password for user value 172.24.1.1 172.24.1.2 MSCHAPv2 115200 Hardware ATQ0V1H0 0800223665 user1 A-li%le-secret-for-2. Run the following commands: # config -s config.console.ppp.localip=172.24.1.1 Opengear User Manual. Page 287. # config -s config.console.ppp.remoteip=172.24.1.2 # config -s config.console.ppp.auth=MSCHAPv2 # config -s config.console.speed=115200 # config -s config.console.flow=Hardware # config -s config.console.initstring=ATQ0V1H0 # config -s config.console.ppp.enabled=on # config -s config.console.ppp.callback.enabled=on # config -s config.console.ppp.callback.phone1=0800223665 # config -s config.console.ppp.username=user1 # config -s config.console.ppp.password=A-little-secret-for-2. To make the dialed connec!on the default route: # config -s config.console.ppp.defaultroute=on Supported values for se$ngs that are not fixed or user-created are as follows: se&ng Authen!ca!on type Serial port baud rate Parity values Data bits values Stop-bit values Serial port flow control supported values None, PAP, CHAP, and MSCHAPv2. 9600, 19200, 38400, 57600, 115200, and 230400 None, Odd, Even, Mark, and Space 5, 6, 7, and 8 1, 1.5, and 2 Hardware, So&ware, and None If you do not wish to use out-of-band dial-in access the procedure for enabling start-up messages on the console port is documented in chapter 14.3.2. The following command will synchronize the live system with the new configura!on: # config a 13.1.20.DHCP server To enable the DHCP server on the console management LAN, with the following se$ngs: DHCP server se&ng value Default lease !me 200000 seconds Maximum lease !me 300000 seconds DNS server 1 192.168.2.3 DNS server 2 192.168.2.4 Domain name company.com Default gateway 192.168.0.1 IP pool 1 start address 192.168.0.20 IP pool 1 end address 192.168.0.100 Reserved IP address 192.168.0.50 MAC to reserve IP for 00:1e:67:82:72:d9 Name to iden!fy this host John-PC Run the following commands: Opengear User Manual. Page 288. # config -s config.interfaces.lan.dhcpd.enabled=on # config -s config.interfaces.lan.dhcpd.defaultlease=200000 # config -s config.interfaces.lan.dhcpd.maxlease=300000 # config -s config.interfaces.lan.dhcpd.dns1=192.168.2.3 # config -s config.interfaces.lan.dhcpd.dns2=192.168.2.4 # config -s config.interfaces.lan.dhcpd.domain=company.com # config -s config.interfaces.lan.dhcpd.gateway=192.168.0.1 # config -s config.interfaces.lan.dhcpd.pools.pool1.start=192.168.0.20 # config -s config.interfaces.lan.dhcpd.pools.pool1.end=192.168.0.100 # config -s config.interfaces.lan.dhcpd.pools.total=1 # config -s config.interfaces.lan.dhcpd.staticips.staticip1.ip=192.168.0.50 # config -s config.interfaces.lan.dhcpd.staticips.staticip1.mac=00:1e: 67:82:72:d9 # config -s config.interfaces.lan.dhcpd.staticips.staticip1.host=John-PC # config -s config.interfaces.lan.dhcpd.staticips.total=1 The following command will synchronize the live system with the new configura!on: # config -r auth 13.1.21.Services You can manually enable or disable network servers from the command line. For example, if you wanted to guarantee the following server configura!on: service HTTP server HTTPS server Telnet server SSH server SNMP server Respond to ICMP echo requests (Ping replies) TFTP server Run the following commands: state enabled disabled disabled enabled disabled disabled enabled # config -s config.services.http.enabled=on # config -d config.services.https.enabled # config -d config.services.telnet.enabled # config -s config.services.ssh.enabled=on # config -d config.services.snmp.enabled # config -d config.services.pingreply.enabled # config -s config.services.tftp.enabled=on These services run on default port numbers as follows: Opengear User Manual. Page 289. service Telnet SSH TCP RFC2217 unauthtel (Unauthorised Telnet) default port number 2000 3000 4000 5000 6000 To set secondary port ranges for any service the following syntax applies: # config -s config.services.<service>.portbase=<number> For example: to set all these services to run on a port number that is ten higher than their default, run the following commands: # config -s config.services.telnet.portbase=2010 # config -s config.services.ssh.portbase=3010 # config -s config.services.tcp.portbase=4010 # config -s config.services.rfc2217.portbase=5010 # config -s config.services.unauthtel.portbase=6010 The following command will synchronize the live system with the new configura!on: # config -r auth 13.1.22.Nagios To configure NAGIOS with the following se$ngs: se&ng value notes NAGIOS host name cm7116 Name of this system. NAGIOS host address 192.168.0.1 Address of this system. NAGIOS server address 192.168.0.10 Address of upstream NAGIOS server Enable SDT for NAGIOS ext Enabled SDT gateway address 192.168.0.1 Defaults to host address. Prefer NRPE over NSCA Disabled Defaults to disabled. Run the following commands: # config -s config.system.nagios.enabled=on # config -s config.system.nagios.name=cm7116 # config -s config.system.nagios.address=192.168.0.1 # config -s config.system.nagios.server.address=192.168.0.10 # config -s config.system.nagios.sdt.disabled=on # config -s config.system.nagios.sdt.address=192.168.0.1 # config -s config.system.nagios.nrpe.prefer='' The fi&h command disables SDT for Nagios extensions. To configure NRPE with following se$ngs: Opengear User Manual. Page 290. se&ng NRPE port NRPE user NRPE group Allow command arguments value 5600 user1 group1 Enabled Run the following commands: notes Port to listen on for nrpe. Defaults to 5666. User to run as. Defaults to nrpe. Group to run as. Defaults to nobody. # config -s config.system.nagios.nrpe.enabled=on # config -s config.system.nagios.nrpe.port=5600 # config -s config.system.nagios.user=user1 # config -s config.system.nagios.nrpe.group=group1 # config -s config.system.nagios.nrpe.cmdargs=on To configure NSCA with the following se$ngs: se&ng NSCA encryp!on value BLOWFISH NSCA password NSCA check-in interval NSCA port User to run as Group to run as secret 2 minutes 5650 user1 group1 Run the following commands notes can be None, XOR, DES, TRPLEDES, CAST-256, BLOWFISH, TWOFISH, RIJNDAEL-256, SERPENT, GOST Defaults to 5667 Defaults to nsca Defaults to nobody # config -s config.system.nagios.nsca.enabled=on # config -s config.system.nagios.nsca.encryption=BLOWFISH # config -s config.system.nagios.nsca.secret=secret # config -s config.system.nagios.nsca.interval=2 # config -s config.system.nagios.nsca.port=5650 # config -s config.system.nagios.nsca.user=user1 # config -s config.system.nagios.nsca.group=group1 The following command will synchronize the live system with the new configura!on: # config -r auth Opengear User Manual. Page 291. 14. Advanced configura!on Opengear console servers run the embedded Linux opera!ng system. Administrator class users can configure the console server and monitor and manage a%ached serial console and host devices from the command line using Linux commands and the config u!lity (as described in chapter 13). The Linux kernel in the console server also supports GNU bash shell scripts, enabling the Administrator to run custom scripts. This chapter presents a number of useful scripts and scrip!ng tools including · delete-node, which is a general script for dele!ng users, groups, hosts, UPS's etc. · ping-detect, which will run specified commands when a specific host stops responding to ping requests. This chapter then details how to perform advanced and custom management tasks using Opengear commands, Linux commands and the open source tools embedded in the console server: · portmanager serial port management. · raw data access to the ports and modems. · iptables modifica!ons and upda!ng IP filtering rules. · retrieving status informa!on using SNMP and modifying SNMP with net-snmpd. · public key authen!cated SSH communica!ons. Opengear User Manual. Page 292. · SSL, configuring HTTPS and issuing cer!ficates. · using pmpower for NUT and PowerMan power device management. · using IPMItools. · CDK custom development kit. · sms server tools. · disabling mul!cas!ng. 14.1. Custom scrip"ng The console server supports GNU bash shell commands (see appendix 1) enabling the Administrator to run custom scripts. 14.1.1. Custom script to run when boo"ng The /etc/config/rc.local script runs whenever the system boots. By default this script file is empty. You can add any commands to this file if you want them to be run at boot !me. For example, if you want to display hello world, add the following to rc.local: #!/bin/sh echo "Hello World!" If this script has been copied from a Windows machine you may need to run the following command on the script before bash can run it successfully: # dos2unix /etc/config/rc.local Another scenario would be to call another custom script from the /etc/config/rc.local file, ensuring that your custom script will run whenever the system is booted. 14.1.2. Running custom scripts when alerts are triggered Whenever an alert gets triggered, specific scripts get called. These scripts all reside in /etc/ scripts/. Below is a list of the default scripts that get run for each applicable alert. · For a connec!on alert (when a user connects or disconnects from a port or network host): /etc/scripts/portmanager-user-alert (for port connec!ons). /etc/scripts/sdt-user-alert (for host connec!ons). · For a signal alert (when a signal on a port changes state): /etc/scripts/portmanager-signal-alert · For a pa%ern match alert (when a specific regular expression is found in the serial ports character stream): /etc/scripts/portmanager-pattern-alert · For a UPS status alert (when the UPS power status changes between on line, on ba%ery, and low ba%ery): /etc/scripts/ups-status-alert Opengear User Manual. Page 293. · For an environmental, power and alarm sensor alerts (temperature, humidity, power load and ba%ery charge alerts): /etc/scripts/environmental-alert · For an interface failover alert: /etc/scripts/interface-failover-alert All these scripts do a check to see whether you have created a custom script to run instead. The code that does this check is shown below (an extract from the file /etc/scripts/ portmanager-pattern-alert): # If there's a user-configured script, run it instead scripts[0]="/etc/config/scripts/pattern-alert.${ALERT_PORTNAME}" scripts[1]="/etc/config/scripts/portmanager-pattern-alert" for (( i=0 ; i < ${#scripts[@]} ; i++ )); do if [ -f "${scripts[$i]}" ]; then exec /bin/sh "${scripts[$i]}" fi done This code shows that there are two alterna!ve scripts that can be run instead of the default one. This code first checks whether a file -- /etc/config/scripts/pattern-alert.$ {ALERT_PORTNAME} -- exists. Note: The variable ${ALERT_PORTNAME} must be replaced with port01 or port13 or whichever port the alert should run for. If this file cannot be found, the script checks whether the file /etc/config/scripts/ portmanager-pattern-alert exists. If either of these files exists, the script calls the exec command on the first file that it finds and runs that custom file/script instead. As an example, you can copy the /etc/scripts/portmanager-pattern-alert script file to /etc/config/scripts/portmanager-pattern-alert: · # cd / · # mkdir /etc/config/scripts Note: this command assumes the directory created does not already exist. · # cp /etc/scripts/portmanager-pattern-alert \ /etc/config/scripts/portmanager-pattern-alert The next step is to edit the new script file. · Open the file /etc/config/scripts/portmanager-pattern-alert using vi (or other text editor). · remove the lines that check for a custom script (the code from above). This will prevent the new custom script from repeatedly calling itself. A&er these lines have been removed, edit the file, or add any addi!onal scrip!ng to the file. Opengear User Manual. Page 294. 14.1.3. Example script: power cycling on pa'ern match If for example we had an RPC (PDU) connected to port 1 on a console server and also have some telecommunica!ons device connected to port 2 and which is powered by the RPC outlet 3. Now assume the telecom device transmits a character stream Emergency out on its serial console port every !me that it encounters some specific error, and the only way to fix this error is to power cycle the telecom device. The first step is to setup a pa%ern-match alert on port 2 to check for the pa%ern Emergency. Next we need to create a custom script to deal with this alert: # cd / # mkdir /etc/config/scripts /* if the directory does not already exist */ # cp /etc/scripts/portmanager-pattern-alert \ /etc/config/scripts/portmanager-pattern-alert Note: make sure to remove the if statement (which checks for a custom script) from the new script, in order to prevent an infinite loop. The pmpower u!lity is used to send power commands to RPC device in order to power cycle our telecom device: # pmpower -l port01 -o 3 cycle The RPC is on serial port 1. The telecom device is powered by RPC outlet 3. We can now append this command to our custom script. This will guarantee that our telecom device will be power cycled every !me the console reads the Emergency character stream on port 2. 14.1.4. Example script: mul"ple e-mail no"fica"ons on each alert If you desire to send more than one email when an alert triggers, you have to create a replacement script using the method described above and add the appropriate lines to your new script. Currently, there is a script /etc/scripts/alert-email which gets run from within all the alert scripts (for example portmanager-user-alert or environmental-alert). The alert-email script is responsible for sending the email. The line which invokes the email script looks as follows: /bin/sh /etc/scripts/alert-email $suffix & If you wish to send another email to a single address or the same email to many recipients, edit the custom script appropriately. You can follow the examples in any of the seven alert scripts listed above. Consider the portmanager-user-alert script. If you need to send the same alert email to more than one email address, find the lines in the script responsible for invoking the alert-email script, then add the following lines below the exis!ng lines: export TOADDR="emailaddress@domain.com" /bin/sh /etc/scripts/alert-email $suffix & These two lines assign a new email address to TOADDR and invoke the alert-email script in the background. Opengear User Manual. Page 295. 14.1.5. Dele"ng configura"on values from the CLI The delete-node script is provided to help with dele!ng nodes from the command line. The delete-node script takes one argument, the node name you want to delete (for example config.users.user1 or config.sdt.hosts.host1). delete-node is a general script for dele!ng any node you desire (users, groups, hosts, UPS's etc) from the command line. The script deletes the specified node and shuffles the remainder of the node values. For example if we have five users configured and we use the script to delete user 3, then user 4 will become user 3, and user 5 will become user 4. This creates an obvious complica!on as this script does not check for any other dependencies that the node being deleted may have had. So you are responsible for making sure that any references and dependencies connected to the deleted node are removed or corrected in the config.xml file. The script treats all nodes the same. The syntax to run the script is # ./delete-node {node name} so to remove, for example, user 3: # ./delete-node config.users.user3 The delete-note script # !/bin/bash # User must provide the node to be removed. eg "config.users.user1" # Usage: delete-node {full node path} if [ $# != 1 ] then echo "Wrong number of arguments" echo "Usage: delnode {full '.' delimited node path}" exit 2 fi # test for spaces TEMP=`echo "$1" | sed 's/.* .*/N/'` if [ "$TEMP" = "N" ] then echo "Wrong input format" echo "Usage: delnode {full '.' delimited node path}" exit 2 fi # testing if node exists TEMP=`config -g config | grep "$1"` if [ -z "$TEMP" ] then echo "Node $1 not found" exit 0 fi Opengear User Manual. Page 296. # LASTFIELD: last field in the node path. eg "user1" # ROOTNODE: upper level of the node. eg "config.users" # NUMBER: integer value extracted from LASTFIELD e.g. "1" # TOTALNODE: node name for the total e.g. "config.users.total" # TOTAL: value of the total number of items before deleting eg "3" # NEWTOTAL: modified total i.e. TOTAL-1 # CHECKTOTAL checks if TOTAL is the actual total items in .xml LASTFIELD=${1##*.} ROOTNODE=${1%.*} NUMBER=`echo $LASTFIELD | sed 's/^[a-zA-Z]*//g'` TOTALNODE=`echo ${1%.*} | sed 's/\(.*\)/\1.total/'` TOTAL=`config -g $TOTALNODE | sed 's/.* //'` NEWTOTAL=$[ $TOTAL -1 ] # Make backup copy of config file cp /etc/config/config.xml /etc/config/config.bak echo "backup of /etc/config/config.xml saved in /etc/config/ config.bak" if [ -z $NUMBER ] # test whether a singular node is being \ # deleted e.g. config.sdt.hosts then echo "Deleting $1" config -d "$1" echo Done exit 0 elif [ $NUMBER = $TOTAL ] # Test if only one item exists then echo "only one item exists" # Deleting node echo "Deleting $1" config -d "$1" # Modifying item total. config -s "$TOTALNODE=0" echo Done exit 0 elif [ $NUMBER -lt $TOTAL ] # more than one item exists then # Modify the users list so user numbers are sequential # by shifting the users into the gap one at a time... echo "Deleting $1" LASTFIELDTEXT=`echo $LASTFIELD | sed 's/[0-9]//g'` CHECKTOTAL=`config -g $ROOTNODE.$LASTFIELDTEXT$TOTAL` if [ -z "$CHECKTOTAL" ] Opengear User Manual. Page 297. then echo "WARNING: "$TOTALNODE" greater than number of items" fi COUNTER=1 while [ $COUNTER != $((TOTAL-NUMBER+1)) ] do config -g $ROOTNODE.$LASTFIELDTEXT$((NUMBER+COUNTER)) \ | while read LINE do config -s \ "`echo "$LINE" | sed -e "s/$LASTFIELDTEXT$((NUMBER+ \ COUNTER))/$LASTFIELDTEXT$((NUMBER+COUNTER-1))/" \ -e 's / /=/'`" done let COUNTER++ done # deleting last user config -d $ROOTNODE.$LASTFIELDTEXT$TOTAL # Modifying item total. config -s "$TOTALNODE=$NEWTOTAL" echo Done exit 0 else echo "error: item being deleted has an index greater than total items. Increase the total count variable." exit 0 fi 14.1.6. Power cycle any device upon a ping request failure The ping-detect script is designed to run specified commands when a monitored host stops responding to ping requests. The first parameter taken by the ping-detect script is the hostname or IP address of the device to ping. Any other parameters are then regarded as a command to run whenever the ping to the host fails. ping-detect can run any number of commands. Below is an example using ping-detect to power cycle an RPC (PDU) outlet whenever a specific host fails to respond to a ping request. ping-detect is run from /etc/config/ rc.local to make sure that the monitoring starts whenever the system boots. We assume we have a serially controlled RPC connected to port01 on a console server and have a router powered by outlet 3 on the RPC and the router has an internal IP address of 192.168.22.2. The following instruc!ons will show you how to con!nuously ping the router and, when the router fails, to respond to a series of pings, the console server will send a command to RPC outlet 3 to power cycle the router, and write the current date/!me to a file. · Copy the ping-detect script to /etc/config/scripts/ on the console server. Opengear User Manual. Page 298. · Open /etc/config/rc.local using vi (or another text editor). · Add the following line to rc.local: /etc/config/scripts/ping-detect 192.168.22.2 /bin/bash -c \ "pmpower -l port01 -o 3 cycle && date" > /tmp/output.log & The above command will cause the ping-detect script to con!nuously ping the host at 192.168.22.2, which is the router. If the router crashes it will no longer respond to ping requests. If this happens, the two commands pmpower and date will run. The output from these commands is sent to the file /tmp/output.log so that we have some kind of record. The ping-detect is also run in the background using the &. The rc.local script is only run by default when the system boots. You can manually run the rc.local script or the ping-detect script if desired. The above is just one example of using the ping-detect script. The idea of the script is to run any number of commands when a specific host stops responding to ping requests. Here are details of the ping-detect script itself. The ping-detect script # !/bin/sh # Usage: ping-detect HOST [COMMANDS...] # This script takes 2 types of arguments: hostname/IPaddress # to ping, and the commands to run if the ping fails 5 times # in a row. This script can only take one host/IPaddress per # instance. Multiple independent commands can be sent to the # script. The commands will be run one after the other. # # PINGREP is the entire reply from the ping command # LOSS is the percentage loss from the ping command # $1 must be the hostname/IPaddress of device to ping # $2... must be the commands to run when the pings fail. COUNTER=0 TARGET="$1" shift # loop indefinitely: while true do # ping the device 10 times PINGREP=`ping -c 10 -i 1 "$TARGET" ` # get the packet loss percentage LOSS=`echo "$PINGREP" | grep "%" | \ sed -e 's/.* \([0-9]*\)% .*/\1/'` if [ "$LOSS" -eq "100" ] then COUNTER=`expr $COUNTER + 1` else COUNTER=0 sleep 30s fi if [ "$COUNTER" -eq 5 ] Opengear User Manual. Page 299. then COUNTER=0 "$@" sleep 2s fi done 14.1.7. Running custom scripts when a configurator is invoked A configurator is responsible for reading the values in /etc/config/config.xml and making the appropriate changes live. Some changes made by the configurators are part of the Linux configura!on itself such as user passwords or ipconfig. Currently there are nineteen configurators, each one responsible for a specific group of config. For example, the users configurator makes the user configura!ons in the config.xml file live. To see all the available configurators type the following from a command line prompt: # config When a change is made using the Management Console web GUI the appropriate configurator is automa!cally run. This can be problema!c. If another user or administrator makes a change using the Management Console the configurator could possibly overwrite any custom CLI/linux configura!ons you may have set. The solu!on is to create a custom script that runs a&er each configurator has run. So a&er each configurator runs it will check whether that appropriate custom script exists. You can then add any commands to the custom script and they will be invoked a&er the configurator runs. The custom scripts must be in the correct loca!on: /etc/config/scripts/config-post- To create an alerts custom script: # cd /etc/config/scripts # touch config-post-alerts # vi config-post-alerts This script could be used to recover a specific backup config or overwrite a config or make copies of config files etc. 14.1.8. Backing-up the configura"on and restoring using a local USB s"ck The /etc/scripts/backup-usb script has been wri%en to save and load custom configura!on using a USB flash disk. Before saving a configura!on locally, you must prepare the USB storage device for use. To do this, disconnect all USB storage devices except for the storage device you wish to use. Usage: /etc/scripts/backup-usb COMMAND [FILE] Opengear User Manual. Page 300. command notes check-magic Check volume label. set-magic Set volume label. save file Save configura!on to USB. delete file Delete a configura!on tarball from USB. list List available config backups on USB load file Load a specific config from USB. load-default Load the default configura!on. set-default file Set which file becomes the default. The first thing to do is to check if the USB disk has a label: # /etc/scripts/backup-usb check-magic If this command returns Magic volume not found, then run the following command: # /etc/scripts/backup-usb set-magic To save the configura!on: # /etc/scripts/backup-usb save config-20May To check if the backup was saved correctly: # /etc/scripts/backup-usb list If this command does not display * config-20May then there was an error saving the configura!on. The set-default command takes an input file as an argument and renames it to default.opg. This default configura!on remains stored on the USB disk. The next !me you want to load the default config, it will be sourced from the new default.opg file. To set a config file as the default: # /etc/scripts/backup-usb set-default config-20May To load this default: # /etc/scripts/backup-usb load-default To load any other config file: # /etc/scripts/backup-usb load {filename} The /etc/scripts/backup-usb script can be executed directly with various commands or called from other custom scripts you may create. However it is recommended that you do not customize the /etc/scripts/backup-usb script itself. 14.1.9. Backing-up the configura"on off-box If you do not have a USB port on your console server you can back up the configura!on to an off-box file. Before backing up you need to arrange a way to transfer the backup off-box. This could be via an NFS share, a Samba (Windows) share to USB storage or copied off-box via the network. If backing up directly to off-box storage, make sure it is mounted. Opengear User Manual. Page 301. /tmp is not a good loca!on for the backup except as a temporary loca!on before transferring it off-box. The /tmp directory will not survive a reboot. The /etc/config directory is not a good place either: it will not survive a restore. Backup and restore should be done by the root user to ensure correct file permissions are set. The config command is used to create a backup tarball: # config -e <Output File> The tarball will be saved to the indicated loca!on. It will contain the contents of the /etc/ config/ directory in an uncompressed and unencrypted form. Example nfs storage: # mount -t nfs 192.168.0.2:/backups /mnt # config -e /mnt/ \ cm7116.config # umount/mnt/ Example transfer off-box via scp: # config -e /tmp/cm7116.config # scp /tmp/cm7116.config username@192.168.0.2:/backups The config command is also used to restore a backup: # config -i <Input File> This will extract the contents of the previously created backup to /tmp, and then synchronize the /etc/config directory with the copy in /tmp. One problem that can crop up here is that there is not enough room in /tmp to extract files to. The following command will temporarily increase the size of /tmp: # mount -t tmpfs -o remount,size=2048k tmpfs /var If restoring to either a new unit or one that has been factory defaulted, it is important to make sure that the process genera!ng SSH keys is either stopped or completed before restoring configura!on. If this is not done, then a mix of old and new keys may be put in place. SSH uses these keys to avoid man-in-the-middle a%acks, logging in may be disrupted. 14.2. Advanced PortManager Opengear's portmanager manages console server serial ports. It routes network connec!ons to serial ports, checks permissions, and monitors and logs all data flowing to and from ports. 14.2.1. PortManager commands pmshell The pmshell command behaves similarly to standard tip or cu commands, but all serial port access is directed via the portmanager. For example, to connect to port 8 via the portmanager: # pmshell -l port08 Opengear User Manual. Page 302. pmshell commands Once connected, the pmshell command supports a subset of the ~ escape commands that tip and cu support. For SSH you must prefix the escape with an addi!onal ~ character. That is, over SSH use the ~~ escape sequence. Firmware v3.5.2 and later includes the pmshell chooser escape command. You can now use ~m (or ~~m over SSH) from connected serial port to drop back to pmshell. For console servers running firmware v3.11.0 and later, pmshell has a set of key sequences built in to access things like the power menu, return to the serial port selec!on menu and so on. command over ssh notes ~b ~~b Generates a BREAK on the connected-to serial port. ~h ~~h Generates a history on the connected-to serial port. Depends on port logging being enabled. ~p ~~p Opens the power menu for the connected-to serial port. Said port must be configured for an RPC. ~m ~~m Connect to the port menu. Goes back to the serial port selec!on menu. ~? ~~? Shows the pmshell help message. ~ ~~ Quits pmshell. ~rts=[x] ~~rts=[x] Sets RTS to [x]. -signals -signals Shows all signals: 3DSR=1, DTR=1, CTS=1, RTS=1, DCD=0. -getline -getline Reads a line of text from the serial port. Extra controls (key sequences) can be added to the built in set of key sequences and can be configured per serial port. You can have all ports behave the same or selec!vely add control sequences to ports. The controls can be different from port to port for the same func!on. For example, you could configure pmshell such that when you are using serial port 2, pressing Ctrl+p would take you straight to the power menu for that port. The pmshell control commands are configurable only via the command line. Note: The pmshell help message is not updated with informa#on about any custom control command keys that are configured. There is a helper script which will configure a control command on a range of serial ports to eliminate the cumbersome task of entering the configura!on command for every port. You will s!ll need to use this script once per control func!on (see below) but there are only six of these. per port control command config parameters config.ports.portX.ctrlcode.break config.ports.portX.ctrlcode.portlog config.ports.portX.ctrlcode.power config.ports.portX.ctrlcode.chooser config.ports.portX.ctrlcode.quit config.ports.portX.ctrlcode.help notes Generates a BREAK. View history open power menu connect to port menu exit pmshell show help message As an example, to configure Ctrl+p to open the power menu when using serial port 3, enter Opengear User Manual. Page 303. the following in the console server's command shell: config -s config.ports.port3.ctrlcode.power=16 killall -HUP portmanager The first command sets the power menu command to listen for Ctrl+p. Decimal 16 is the character code sent when you press Ctrl+p in the serial port session (see the control codes table immediately below). The second command -- killall -HUP portmanager -- tells portmanager to reload the configura!on so that the new control code will take effect. Reboo!ng the device would also work. There is a script to set serial control codes on a range of ports so that bulk port configura!on can be performed more easily. For example to set the power menu control code to CTRL-P (keycode 16) on ports 4 to 10 inclusive, enter the following at the command line: /etc/scripts/set-serial-control-codes 4 10 power 16 This sets the power menu control key to Ctrl+p. Note: If you've not configured anything on a par#cular serial port in the included range, configura#on for that port will be skipped. pmchat control code decimal control code decimal control code decimal ctrl+a 1 ctrl+j 10 ctrl+s 19 ctrl+b 2 ctrl+k 11 ctrl+t 20 ctrl+c 3 ctrl+l 12 ctrl+u 21 ctrl+d 4 ctrl+m 13 ctrl+v 22 ctrl+e 5 ctrl+n 14 ctrl+w 23 ctrl+f 6 ctrl+o 15 ctrl+x 24 ctrl+g 7 ctrl+p 16 ctrl+y 25 ctrl+h 8 ctrl+q 17 ctrl+z 26 ctrl+i 9 ctrl+r 18 The pmchat command is similar to the standard chat command, but all serial port access is directed via the portmanager. For example, to run a chat script via the portmanager: # pmchat -v -f /etc/config/scripts/port08.chat < /dev/port08 For more informa!on on using chat and pmchat you should consult the u!lity's manual page, via the man chat command on any Linux or UNIX (including macOS) system, or via the web, including at h%ps://linux.die.net/man/8/chat. pmusers The pmusers command is used to query the portmanager for ac!ve user sessions. For example, to detect which users are currently ac!ve on which serial ports: # pmusers Opengear User Manual. Page 304. This will output nothing if there are no ac!ve users currently connected to any ports. If users are connected it will respond with a sorted list of usernames per ac!ve port. For example: Port 1: user1 user2 Port 2: user1 Port 8: user2 The above output indicates that a user named user1 is ac!vely connected to ports 1 and 2, while user2 is connected to both ports 1 and 8. With firmware v3.11 and later the pmusers command is extended with the --disconnect op!on. This allows an administrator or root to disconnect console server sessions from the command line. The following connec!on types can be disconnected: telnet SSH Raw TCP Unauthorized Telnet The --disconnect op!on cannot disconnect an RFC2217 session. If the --disconnect op!on is specified, the pmusers command goes into disconnect mode where you can specify users with -u and ports with -l (by label) or -n (by name). By default the command will prompt the user before actually disconnec!ng the matching sessions. This can be overriden with the --no-prompt argument. Some example pmuser sessions: # pmusers --disconnect Disconnect all users from all ports? (y/n) y 5 sessions were disconnected # pmusers --disconnect -u robertw Disconnect user robertw from all ports? (y/n) y 1 session was disconnected # pmusers --disconnect -u robertw -n 5 Disconnect user robertw from port 5 (BranchRouter01)? (y/n) y No sessions were disconnected # pmusers --disconnect -n 5 Disconnect all users from port 5 (BranchRouter01)? (y/n) y 2 sessions were disconnected # pmusers --disconnect -u robertw -u pchunt -n 4 -n 6 Disconnect users robertw, pchunt from ports 4, 6? (y/n) Opengear User Manual. Page 305. y 10 sessions were disconnected # pmusers --disconnect -u tester --no-prompt No sessions were disconnected portmanager dæmon There is normally no need to stop and restart the dæmon. To restart the dæmon normally, just run the command: # portmanager Supported command line op!ons are: op"on purpose -nodaemon Force portmanager to run in the foreground --loglevel={debug | info |warn | error | alert} Set the level of debug logging -c /etc/config/portmanager.conf Change which configura!on file it uses signals Sending a SIGHUP signal to the portmanager will cause it to re-read its configura!on file. 14.2.2. External scripts & alerts The portmanager has the ability to execute external scripts on certain events. When a port is opened by the portmanager When portmanager opens a port, it a%empts to execute /etc/config/scripts/ portXX.init (where XX is the number of the port, for example 08). The script is run with STDIN and STDOUT both connected to the serial port. If the script cannot be executed, portmanager executes /etc/config/scripts/ portXX.chat via the chat command on the serial port. When an alert occurs on a port When an alert occurs on a port, portmanager a%empts to execute /etc/config/ scripts/portXX.alert (where XX is the port number, for example 08). The script is run with STDIN containing the data which triggered the alert, and STDOUT redirected to /dev/null, not to the serial port. If you wish to communicate with the port, use pmshell or pmchat from within the script. If the script cannot be executed, the alert will be mailed to the address configured in the system administra!on sec!on. When a user connects to any port If a file called /etc/config/pmshell-start.sh exists it is run when a user connects to a port. It is provided 2 arguments, the Port number and the Username. Here is a simple example: </etc/config/pmshell-start.sh> #!/bin/sh Opengear User Manual. Page 306. PORT="$1" USER="$2" echo "Welcome to port $PORT $USER" </etc/config/pmshell-start.sh> The return value from the script controls whether the user is accepted or not, if 0 is returned (or nothing is done on exit as in the above script) the user is permi%ed, otherwise the user is denied access. Here is a more complex script which reads from configura!on to display the port label if available and denies access to the root user: </etc/config/pmshell-start.sh> #!/bin/sh PORT="$1" USER="$2" LABEL=$(config -g config.ports.port$PORT.label | cut -f2- -d' ') if [ "$USER" == "root" ]; then echo "Permission denied for Super User" exit 1 fi if [ -z "$LABEL" ]; then echo "Welcome $USER, you are connected to Port $PORT" else echo "Welcome $USER, you are connected to Port $PORT ($LABEL)" fi </etc/config/pmshell-start.sh> 14.3. Raw access to serial ports 14.3.1. Access to serial ports You can use tip and stty to completely bypass the portmanager and have raw access to the serial ports. When you run tip on a portmanager-controlled port, portmanager closes that port, and stops monitoring it un!l tip releases control of it. With stty, the changes made to the port only persist un!l that port is closed and opened again. Using stty for more than ini!al debugging of a serial connec!on is not recommended. If you want to use stty to configure a port, you can put stty commands in /etc/config/ scripts/portXX.init which gets run whenever portmanager opens the port Otherwise, any setup you do with stty will be lost when portmanager opens the port. Note: portmanager sets things back to its config rather than using whatever is on the port, so the port is in a known good state, and will work, no ma"er what things are done to the serial port outside of portmanager. 14.3.2. Accessing the console modem port Console dial-in is handled by mgetty, with automa!c PPP login extensions. mgetty is a smart getty replacement, designed for Hayes-compa!ble data and data/fax modems. Opengear User Manual. Page 307. mgetty knows about modem ini!aliza!on, manual modem answering (so your modem doesn't answer if the machine isn't ready), and UUCP locking (so you can use the same device for dial-in and dial-out). mgetty provides extensive logging facili!es. All standard mgetty op!ons are supported. Modem ini"aliza"on strings To override the standard modem ini!aliza!on string either use the Management Console (see chapter 4) or the command line config tool (see chapter 14). Enabling boot messages on the console If you are not using a modem on the DB9 console port and instead wish to connect to it directly via a Null Modem cable you may want to enable verbose mode allowing you to see the standard linux start-up messages. This can be achieved with the following commands: # /bin/config --set=config.console.debug=on # /bin/config \ --run=console # reboot If at some point in the future you chose to connect a modem for dial-in out-of-band access the procedure can be reversed with the following commands: # /bin/config --del=config.console.debug # /bin/config --run=console # reboot 14.4. IP filtering The console server uses the iptables u!lity to provide a stateful firewall of LAN traffic. By default, rules are automa!cally inserted to allow access to enabled services, and serial port access via enabled protocols. The commands which add these rules are in configura!on files: /etc/config/fw.rules This is an executable shell script which is run whenever the LAN interface is brought up and whenever modifica!ons are made to the iptables configura!on as a result of CGI ac!ons or the config command line tool. The basic steps performed are as follows: · the running iptables configura!on is erased, per-interface. · other standard system chains are installed. · fall-through Block rules (default deny) are installed. · Serial & Network > Services policies are installed in per-interface chains. · Custom Serial & Network > Firewall rules are inserted at the top of the rule sets, taking priority over any other configura!on For further firewall customiza!on, extra rules can be persisted by crea!ng a file at /etc/ config/scripts/firewall-post containing iptables commands to amend the firewall policy. Thorough documenta!on regarding iptables is available at the Linux netfilter website, at h%ps://netfilter.org/documenta!on/. Opengear User Manual. Page 308. 14.5. SNMP status repor"ng Console servers contain an SNMP Service -- snmpd -- which can provide status informa!on on demand. snmpd is an SNMP agent which binds to a port and awaits requests from SNMP management so&ware. Upon receiving a request, it processes the request(s), collects the requested informa!on and/or performs the requested opera!on(s) and returns the informa!on to the sender. Note: ini#ally only advanced console server models were equipped with an SNMP Service. With firmware v3.0 and later this support was extended to all console servers. Also the MIBS were extended (and renamed for compliance) with this firmware release. Console servers can also be configured to send SNMP traps or messages to mul!ple remote SNMP Network Managers on defined trigger events. See chapter 6 for configura!on details. 14.5.1. Retrieving status informa"on using SNMP Console servers can provide serial and device status informa!on through SNMP. This includes · Serial port status · Ac!ve users · Remote Power Control (RPC) and Power Distribu!on Unit (PDU) status · Environmental Monitoring Device (EMD) status · Signal alert status · Environmental alert status and · UPS alert status The MIBs in your console server are located in /etc/snmp/mibs. They include: MIB OG-STATUS-MIB notes Contains serial and connected device status informa!on for snmpstatusd and snmpalertd. OG-STATUSv2-MIB This MIB contains extended status and alerts. OG-SMI-MIB Enterprise structure of management informa!on. OGTRAP-MIB SMIv1 traps from old MIBS as smilint will not let SMIv1 structures coexist with SMIv2. OGTRAPv2-MIB Updated traps. 14.5.2. Check firewall rules · Navigate to System > Services. · Check the SNMP dæmon checkbox for the required interface. This allows SNMP requests through the specified interface's firewall. 14.5.3. Enable SNMP service Console servers support different SNMP versions including SNMPv1, SNMPv2c and SNMPv3. Opengear User Manual. Page 309. Although an industry standard, SNMP brings with it a variety of security concerns. For example, SNMPv1 and SNMPv2c offer no inherent privacy, while SNMPv3 is suscep!ble to man-in-the-middle a%acks. Recent IETF developments suggest tunnelling SNMP over widely accepted technologies such as SSH (Secure Shell) or TLS (Transport Layer Security) rather than relying on a less mature security systems such as SNMPv3's USM (User-based Security Model). Addi!onal informa!on regarding SNMP security issues and SNMPv3 can be found at h%p:// net-snmp.sourceforge.net/wiki/index.php/TUT:Security. · Navigate to Alerts & Logging > SNMP. The SNMP Service Details tab shows by default. This tab controls aspects of the SNMP service including security level. It also manages requests from external agents for Opengear status informa!on. · Check the Enable the SNMP Service to start the SNMP service. SNMP is disabled by default. · Select either UDP or TCP for the TCP/IP Protocol. UDP is the recommended protocol and is selected by default. TCP should only be used in special cases, such as when Port Forwarding SNMP requests/responses to or from the Opengear device is required. · Complete the Loca"on and Contact fields. The Loca!on field should describe the physical loca!on of the Opengear and will be used in response to requests for the SNMPv2-MIB::sysLoca!on.0 of the device. The Contact field refers to the person responsible for the Opengear such as the System Administrator and will be used in response to requests as follows: SNMPv2MIB::sysContact.0. · Enter the Read-Only Community and Read-Write Community. This is required for SNMP v1 & v2c only. The Read-Only Community field is used to specify the SNMPv1 or SNMPv2c community that will be allowed read-only (GET and GETNEXT) access. This must be specified in order for both versions to become enabled. The ReadWrite Community field is used to specify the SNMPv1 or SNMPv2c community that will be allowed read-write (GET, GETNEXT and SET) access. Opengear User Manual. Page 310. · Configure SNMPv3, if required. SNMPv3 provides secure SNMP opera!ons through the use of USM (User-based Security Model). It offers various levels of security including user-based authen!ca!on and basic encryp!on. · Enter an Engine ID if required. Engine ID is used to localize the SNMPv3 user. It will be automa!cally generated from a Network Interface (eth0) hardware address, if le& blank, or must be entered as a hex value (for example, 0x01020304). · Specify the Security Level. security level notes noauth No authen!ca!on or encryp!on required. This is the minimum security level. auth Authen!ca!on will be required but encryp!on is not enforced. An authen!ca!on protocol (SHA or MD5) and password will be required. priv Enforces encryp!on use. This is the highest level of security and requires an encryp!on protocol (DES or AES) and password in addi!on to the authen!ca!on protocol and password. · Enter the Read Only Username. This field is mandatory when configuring the console server for SNMPv3. · For a Security Level of auth, set the Auth Protocol (SHA or MD5) and the Auth Password. A password of at least 8 characters is required. Opengear User Manual. Page 311. · For a Security Level of priv, set the Privacy Protocol (DES or AES) and the Privacy Password. AES is recommended. A password of at least 8 characters is required. · Click Apply. · Setup serial ports and devices as per requirements such as UPS, RPC/PDU and EMD. · Copy the mibs from /etc/snmp/mibs on the console server to a local directory using scp or Winscp. For example: scp root@im4004:/etc/snmp/mibs/* · Using the snmpwalk and snmpget commands, status informa!on can be retrieved from any console server. For example: snmpwalk -Oa -v1 -M .:/usr/share/snmp/mibs -c public im4004 OGSTATUS-MIB::ogStatus Opengear User Manual. Page 312. snmpget -Oa -v1 -M .:/usr/share/snmp/mibs -c public im4004 OGSTATUSMIB::ogSerialPortStatusSpeed.2 noauth snmpwalk -Oa v3 l noAuthNoPriv u readonlyusername -M .:/usr/ share/snmp/mibs im4004 OG-STATUS-MIB::ogStatus auth snmpwalk -Oa v3 l authNoPriv u readonlyusername a SHA A "authpassword" -M .:/usr/share/snmp/mibs im4004 OG-STATUSMIB::ogStatus priv snmpwalk -Oa v3 l authNoPriv u readonlyusername a SHA A "authpassword" x DES X "privpassword" -M .:/usr/share/snmp/mibs im4004 OG-STATUS-MIB::ogStatus snmp argument -l -u -a -A -x -X purpose security level. security name or read-only username. authen!ca!on protocol: SHA or MD5. authen!ca!on password. privacy protocol: DES or AES. privacy password. A mib browser can explore the Opengear enterprise MIB structure. For example, the ogStatus tree is shown below: Opengear User Manual. Page 313. 14.5.4. Adding mul"ple remote SNMP managers You can add mul!ple SNMP servers for alert traps. Add the first and second SNMP servers using the Management Console (see chapter 6) or the command line config tool. Further SNMP servers must be added manually using config. Log in to the console server's command line shell as root or an admin user. · Set the SNMP Manager Address field: config set="config.system.snmp.address3=w.x.y.z" replacing w.x.y.z with the IP address or hostname. · Set the Manager Trap Port field: config --set="config.system.snmp.trapport3=162" replacing 162 with the TCP/UDP port number · Set the SNMP Manager Protocol field: config --set="config.system.snmp.protocol3=UDP" or config --set="config.system.snmp.protocol3=TCP" · Set the SNMP Manager Version field: config --set="config.system.snmp.version3=3" · Set the SNMP Manager v1 & v2c community field: config --set="config.system.snmp.community3=public" · Set the SNMP Manager v3 Engine ID field: config set="config.system.snmp.engineid3=0x8000000001020304" replacing 0x8000000001020304 with the hex Engine-ID. · Set the SNMP Manager v3 Security Level field: config --set="config.system.snmp.seclevel3=noAuthNoPriv" or config --set="config.system.snmp.seclevel3=authNoPriv" or config --set="config.system.snmp.seclevel3=authPriv" · Set the SNMP Manager v3 Username field: config --set="config.system.snmp.username3=username" · Set the SNMP Manager v3 Auth. Protocol and password fields: config set="config.system.snmp.authprotocol3=SHA" Opengear User Manual. Page 314. or config --set="config.system.snmp.authprotocol3=MD5" config --set="config.system.snmp.authpassword3=password 1" · To set the SNMP Manager v3 Privacy Protocol and password fields: config set="config.system.snmp.privprotocol3=AES" or config set="config.system.snmp.privprotocol3=DES" config --set="config.system.snmp.privpassword3=password 2" · Once the fields are set, apply the configura!on with the following command: config --run snmp You can add a third or more SNMP servers by incremen!ng the 2 in the above commands. For example, config.system.snmp.protocol3, config.system.snmp.address3, etc. 14.6. Secure shell (SSH) public key authen"ca"on This sec!on covers the genera!on of public and private keys in a Linux and Windows environment and configuring SSH for public key authen!ca!on. The steps to use in a Clustering environment are: · generate a new public and private key pair. · upload the keys to the master and to each slave console server. · fingerprint each connec!on to validate. 14.6.1. SSH overview Popular TCP/IP applica!ons such as telnet, rlogin, ftp, and others transmit their passwords unencrypted. Doing this across pubic networks like the Internet can have catastrophic consequences. It leaves the door open for eavesdropping, connec!on hijacking, and other network-level a%acks. Secure Shell (SSH) is a program to log into another computer over a network, to execute commands in a remote machine, and to move files from one machine to another. It provides strong authen!ca!on and secure communica!ons over insecure channels. OpenSSH, the de facto open source SSH applica!on, encrypts all traffic (including passwords) to effec!vely eliminate these risks. Addi!onally, OpenSSH provides a myriad of secure tunneling capabili!es, as well as a variety of authen!ca!on methods. OpenSSH is the port of OpenBSD's excellent OpenSSH[0] to Linux and other versions of Unix. OpenSSH is based on the last free version of Tatu Ylonen's sample implementa!on with all patent-encumbered algorithms removed (to external libraries), all known security bugs fixed, new features reintroduced and many other clean-ups. The only changes in the Opengear SSH implementa!on are: · PAM support. Opengear User Manual. Page 315. · EGD[1]/PRNGD[2] support and replacements for OpenBSD library func!ons that are absent from other versions of UNIX. · The config files are now in /etc/config/. For example: /etc/config/sshd_config not /etc/sshd_config /etc/config/ssh_config not /etc/ssh_config /etc/config/users/<username>/.ssh / not /home/<username>/.ssh/ 14.6.2. Genera"ng public keys (Linux) To generate new SSH key pairs use the Linux ssh-keygen command. This produces an RSA or DSA public/private key pair. You will be prompted for a path to store the two key files: id_dsa.pub (the public key) and id_dsa (the private key). For example: $ ssh-keygen -t [rsa|dsa] Generating public/private [rsa|dsa] key pair. Enter file in which to save the key (/home/user/.ssh/id_[r|dsa]): Enter passphrase (empty for no passphrase): Enter same passphrase again: Your identification has been saved in /home/user/.ssh/id_[r|dsa]. Your public key has been saved in /home/user/.ssh/id_[r|dsa].pub. The key fingerprint is: 28:aa:29:38:ba:40:f4:11:5e:3f:d4:fa:e5:36:14:d6 user@server $ It is advisable to create a new directory to store your generated keys. It is also possible to name the files a&er the device they will be used for. For example: $ mkdir keys $ ssh-keygen -t rsa Generating public/private rsa key pair. Enter file in which to save the key: ~/keys/control_room Enter passphrase (empty for no passphrase): Enter same passphrase again: Your identification has been saved in ~/keys/control_room Your public key has been saved in ~/keys/control_room.pub. The key fingerprint is: 28:aa:29:38:ba:40:f4:11:5e:3f:d4:fa:e5:36:14:d6 user@server $ There must be no password associated with the keys. If there is a password, Opengear devices will have no way to supply it at run!me. Full documenta!on for the ssh-keygen command can be found at h%p://man.openbsd.org/ OpenBSD-current/man1/ssh-keygen.1. 14.6.3. Installing the SSH public & private keys (clustering) For console servers the keys can be uploaded through the web interface, on the System > Administra"on page. Opengear User Manual. Page 316. This enables you to upload stored RSA or DSA Public Key pairs to the master and apply the authorized key to the slave as documented in chapter 3. Once complete you then proceed to Fingerprin!ng as documented below. 14.6.4. Installing SSH public key authen"ca"on (Linux) Alternately the public key can be installed on the unit remotely from the linux host with the scp u!lity as follows. Assump!ons: · the Management Console username is fred. · the console server IP address is 192.168.0.1 (a console server's default private IP address). · the public key is stored on the Linux- or UNIX-based system in ~/.ssh/id_dsa.pub. Given this, run the following command from the Linux- or UNIX-based system: scp ~/.ssh/id_dsa.pub \ root@192.168.0.1:/etc/config/users/fred/.ssh/authorized_keys Opengear User Manual. Page 317. This copies the file to the console server but doesn't set ownership as required. The authorized_keys file on the console server needs to be owned by fred. To affect this, login to the Management Console as root and run the following command: chown fred /etc/config/users/fred/.ssh/authorized_keys If the console server selected to be the server has only one client device, the authorized_keys file is simply a copy of the public key for that device. If one or more devices will be clients of the console server, the authorized_keys file will contain copies of all of the public keys. RSA and DSA keys may be freely mixed in the authorized_keys file. For example, assume we already have one server, called bridge_server, and two sets of keys, for the control_room and the plant_entrance. The following commands 1) show the stored keys and 2) combine two of them into a single file, authorized_keys_bridge_server. $ ls /home/user/keys control_room control_room.pub plant_entrance plant_entrance.pub $ cat ~/keys/control_room.pub ~/keys/plant_entrance.pub > ~/keys/ authorized_keys_bridge_server More OpenSSH documenta!on can be found at h%ps://openssh.com/manual.html and h%p:// man.openbsd.org/OpenBSD-current/man1/ssh.1. Opengear User Manual. Page 318. 14.6.5. Genera"ng public & private keys for SSH (Windows) This sec!on describes how to generate and configure SSH keys using Windows. The OpenSSH project does not produce a Windows binary. The OpenSSH project's development is en!rely focussed on producing `a very small, secure, and easy to maintain version for the OpenBSD project'. The versions of OpenSSH that ship on other Unix- and Unix-like opera!ng systems are managed and produced by the OpenSSH Portability Team. As of 2016-10, and despite Microso& announcing `the PowerShell team will support and contribute to the OpenSSH community... to deliver the PowerShell and Windows SSH solu!on', there is no Windows version of the current OpenSSH release. Consequently, Simon Tatham's long-standing SSH client for Windows, PuTTY, which includes the key generator, PuTTYgen.exe, is used in the following procedure. Before beginning, make sure you have the most recent PuTTYgen release installed. PuTTYgen is available for download from h%p://www.chiark.greenend.org.uk/~sgtatham/ pu%y/download.html. This procedure also requires the current version of WinSCP -- a Windows-equivalent to the scp utlil!y -- be installed. WinSCP is available for download from h%ps://winscp.net/. · Create a new user from the Opengear Management Console. The following example uses a user called testuser. This user must be a member of the users group. · If you do not already have a public/private key pair generate them now using PuTTYgen. · Launch PuTTYgen.exe. · Select the desired key type -- SSH2 DSA -- in the Parameters sec!on. You may use RSA or DSA. · Leave the passphrase field blank. · Click Generate. · As instructed, move the mouse pointer over the blank area of the program in order to create random data used by PUTTYGEN to generate secure keys. Key genera!on occurs once PUTTYGEN has collected sufficient random data. · Copy the public key data from the Public key for pas"ng into OpenSSH authorized_keys file sec!on of the PuTTY Key Generator window. · Launch Notepad (not Microso& Word or any other word processor). · paste the key data into the Notepad window. Make sure there is only one line of text in this file. · Save the Notepad file as authorized_keys. · Launch WinSCP. Opengear User Manual. Page 319. · Copy authorized_keys to the user's home directory on the console server which will be the SSH server. For example, if the user's username is testuser, copy the file to /etc/config/users/testuser/.ssh/authorized_keys · From the console server's command line run the following commands to give the file the correct text-format and the correct permissions: # dos2unix /etc/config/users/testuser/.ssh/authorized_keys # chown testuser /etc/config/users/testuser/.ssh/authorized_keys · Using WinSCP, copy the local sshd_config file over /etc/config/sshd_config on the console server. This ensures public key authen!ca!on is enabled. · Test the public key by logging in to the console server as testuser. · At the console server's command line type the following: # ssh -o StrictHostKeyChecking=no <server-ip> To automate connec!on of the SSH tunnel from the client on every power-up you need to make the client's /etc/config/rc.local look like the following: #!/bin/sh ssh -L9001:127.0.0.1:4001 -N -o \ StrictHostKeyChecking=no testuser@<server-ip> & This will run the tunnel redirec!ng local port 9001 to the server port 4001. 14.6.6. Fingerprin"ng Fingerprints are used to ensure you are establishing an SSH session to who you think you are. On the first connec!on to a remote server you will receive a fingerprint which you can use on future connec!ons. This fingerprint is related to the host key of the remote server. Fingerprints are stored in ~/.ssh/known_hosts. · To receive the fingerprint from the remote server, log in to the client as the required user (usually root) and establish a connec!on to the remote host: # ssh rh The authenticity of host 'rh (192.168.0.1)' can't be established. RSA key fingerprint is 8d:11:e0:7e:8a:6f:ad:f1:94:0f:93:fc: 7c:e6:ef:56. Are you sure you want to continue connecting (yes/no)? · Answer yes to accept the key. · The following message will be returned: Warning: Permanently added 'rh,192.168.0.1' (RSA) to the list of known hosts. Opengear User Manual. Page 320. · You may be prompted for a password. There is no need to log in, however: you have received the fingerprint. · Press Ctrl-C to cancel the connec!on. If the host key changes you will receive the following warning, and not be allowed to connect to the remote host: @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ @ WARNING: REMOTE HOST IDENTIFICATION HAS CHANGED! @ @ IT IS POSSIBLE THAT SOMEONE IS DOING SOMETHING NASTY! @ @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ Someone could be eavesdropping on you right now using a man-in-the-middle a%ack. It is also possible that the RSA host key has just been changed: The fingerprint for the RSA key sent by the remote host is ab:7e:33:bd:85:50:5a:43:0b:e0:bd:43:3f:1c:a5:f8. Please contact your system administrator. Add correct host key in /.ssh/known_hosts to get rid of this message. Offending key in /.ssh/known_hosts:1 RSA host key for remhost has changed and you have requested strict checking. Host key verification failed. If the host key has legi!mately changed, it can be removed from the ~/.ssh/known_hosts file and the new fingerprint added. If it has not changed legi!mately, this indicates a serious problem that should be inves!gated immediately. 14.6.7. SSH tunnelled serial bridging You can apply SSH tunneling when two Black Box console servers are configured for serial bridging. As detailed in chapter 3, the Server console server is setup in Console Server mode with either RAW or RFC2217 enabled and the Client console server is set up in Serial Bridging Mode with the Server Address, and Server TCP Port (4000 + port for RAW or 5000 + port # for RFC2217) specified: · Select SSH Tunnel when configuring the Serial Bridging Se!ng. Opengear User Manual. Page 321. · set up SSH keys for each end of the tunnel and upload these keys to the Server and Client console servers. Client keys The first step in se$ng up ssh tunnels is to generate keys. Ideally, you will use a separate, secure, machine to generate and store all keys to be used on the console servers. However, if this is not ideal to your situa!on, keys may be generated on the console servers themselves. It is possible to generate only one set of keys, and reuse them for every SSH session. While this is not recommended, each organiza!on will need to balance the security of separate keys against the addi!onal administra!on they bring. Generated keys may be one of two types -- RSA or DSA -- and it is beyond the scope of this document to recommend one over the other. RSA keys will go into the files id_rsa and id_rsa.pub. DSA keys will be stored in the files id_dsa and id_dsa.pub. For simplicity going forward the term private key will be used to refer to either id_rsa or id_dsa and public key to refer to either id_rsa.pub or id_dsa.pub. To generate the keys use the ssh-keygen program (part of the OpenSSH suite): $ ssh-keygen -t [rsa|dsa] Opengear User Manual. Page 322. Generating public/private [rsa|dsa] key pair. Enter file in which to save the key (/home/user/.ssh/id_[r| dsa]): Enter passphrase (empty for no passphrase): Enter same passphrase again: Your identification has been saved in /home/user/.ssh/id_[r| dsa]. Your public key has been saved in /home/user/.ssh/id_[r| dsa].pub. The key fingerprint is: 28:aa:29:38:ba:40:f4:11:5e:3f:d4:fa:e5:36:14:d6 user@server $ It is advisable to create a new directory to store your generated keys. It is also possible to name the files a&er the device they will be used for. For example: $ mkdir keys $ ssh-keygen -t rsa Generating public/private rsa key pair. Enter file in which to save the key: ~/keys/control_room Enter passphrase (empty for no passphrase): Enter same passphrase again: Your identification has been saved in ~/keys/control_room Your public key has been saved in ~/keys/control_room.pub. The key fingerprint is: 28:aa:29:38:ba:40:f4:11:5e:3f:d4:fa:e5:36:14:d6 user@server $ There must be no password associated with the keys. If there is a password, Opengear devices will have no way to supply it at run!me. Authorized keys If the console server selected to be the server has only one client device, the authorized_keys file is simply a copy of the public key for that device. If one or more devices will be clients of the console server, the authorized_keys file will contain copies of all of the public keys. RSA and DSA keys may be freely mixed in the authorized_keys file. For example, assume we already have one server, called bridge_server, and two sets of keys, for the control_room and the plant_entrance. The following commands 1) show the stored keys and 2) combine two of them into a single file, authorized_keys_bridge_server. $ ls /home/user/keys control_room control_room.pub plant_entrance plant_entrance.pub $ cat ~/keys/control_room.pub ~/keys/plant_entrance.pub > ~/ keys/authorized_keys_bridge_server Uploading keys Opengear User Manual. Page 323. The keys for the server can be uploaded through the web interface, on the System > Administra"on page as detailed earlier. If only one client will be connec!ng, then simply upload the appropriate public key as the authorized keys file. Otherwise, upload the authorized keys file constructed in the previous step. Each client will then need its own set of keys uploaded through the same page. Take care to ensure that the correct type of keys (DSA or RSA) goes in the correct spots, and that the public and private keys are in the correct spot. 14.6.8. SDT connector public key authen"ca"on SDT Connector can authen!cate against a console server using your SSH key pair rather than requiring your to enter your password (that is public key authen!ca!on). To use public key authen!ca!on with SDT Connector, first create an RSA or DSA key pair (using ssh-keygen, PuTTYgen or a similar tool) and add the public part of your SSH key pair to the console server. Next, add the private part of your SSH key pair (this file is typically named id_rsa or id_dsa) to the SDT Connector client: · Navigate to Edit > Preferences > Private Keys > Add. · Locate the private key file. · Click OK. You do not have to add the public part of your SSH key pair, it is calculated using the private key. SDT Connector will now use public key authen!ca!on when SSH-connec!ng through the console server. You may have to restart SDT Connector to shut down any exis!ng tunnels that were established using password authen!ca!on. If you have a host behind the console server that you connect to by clicking the SSH bu%on in SDT Connector, you can also configure it for public key authen!ca!on. Essen!ally what you are using is SSH over SSH. The two SSH connec!ons are en!rely separate, and the host configura!on is en!rely independent of SDT Connector and the console server. You must configure the SSH client that SDT Connector launches (for example Pu%y or OpenSSH) and the host's SSH server for public key authen!ca!on. 14.7. Secure sockets layer (SSL) support Secure Sockets Layer (SSL) is a protocol developed by Netscape for transmi$ng private documents via the Internet. SSL works by using a private key to encrypt data that's transferred over the SSL connec!on. The console server includes OpenSSL. The OpenSSL Project is a collabora!ve effort to develop a robust, commercial-grade, full-featured, and Open Source toolkit implemen!ng the Secure Sockets Layer (SSL v2/v3) and Transport Layer Security (TLS v1) protocols as well as a fullstrength general purpose cryptography library. The project is managed by a worldwide community of volunteers that use the Internet to communicate, plan, and develop the OpenSSL toolkit and its related documenta!on. Opengear User Manual. Page 324. OpenSSL is based on the Slay library developed by Eric A Young and Tim J Hudson. The OpenSSL toolkit is licensed under an Apache-style license, which basically means that you are free to get and use it for commercial and non-commercial purposes subject to some simple license condi!ons. In the console server OpenSSL is used primarily in conjunc!on with https in order to have secure browser access to the GUI management console across insecure networks. OpenSSL documenta!on is available at h%ps://openssl.org/docs/manmaster/apps/ openssl.html. The OpenSSL project itself `highly recommends' Ivan Ris!'s OpenSSL Cookbook, available as a free download from h%ps://feistyduck.com/books/openssl-cookbook/. 14.8. HTTPS The Management Console UI is served using HTTPS by the built in cherokee webserver. If your default network address is changed or the unit is to be accessed via a known Domain Name you can use the following steps to replace the default SSL Cer!ficate and Private Key with ones tailored for your new address. 14.8.1. Genera"ng an encryp"on key To create a 1024 bit RSA key with a password issue the following command on the command line of a linux host with the openssl u!lity installed: # openssl genrsa -des3 -out ssl_key.pem 1024 14.8.2. Genera"ng a self-signed cer"ficate with OpenSSL This example shows how to use OpenSSL to create a self-signed cer!ficate on a Linux- or Unix-based system. OpenSSL ships as part of macOS and is available for most Linux distribu!ons via the default package management mechanism. The OpenSSL project `does not distribute any code in binary form, and does not officially recommend any specific binary distribu!ons.' The project does, however, maintain a page on its community wiki: h%ps://wiki.openssl.org/index.php/Binaries. This page lists 3rd-party binaries that are `stable and can provide con!nued support for OpenSSL'. Windows users should check here for a suitable binary. To create a 1024-bit RSA key and a self-signed cer!ficate, issue the following command from the host you have openssl installed on: # openssl req -x509 -nodes -days 1000 -newkey rsa:1024 -keyout \ ssl_key.pem -out ssl_cert.pem You will be prompted to enter a lot of informa!on. Most of it doesn't ma%er, but the Common Name should be the domain name of your computer (for example, test.opengear.com). When you have entered everything, the cer!ficate will be created in a file called ssl_cert.pem. 14.8.3. Installing the key & cer"ficate Opengear User Manual. Page 325. The recommended method for copying files securely to the console server unit is with a Secure Copying Protocol client (for example, the shell-based tool: scp). The scp u!lity ships with macOS and ships with OpenSSH for most Linux distribu!ons. Windows users can use something like the PSCP command line u!lity available with PuTTY. The files created in the steps above can be installed remotely with the scp u!lity as follows: # scp ssl_key.pem root@<address of unit>:/etc/config/ # scp ssl_cert.pem root@<address of unit>:/etc/config/ or, using PSCP: pscp -scp ssl_key.pem root@<address of unit>:/etc/config/ pscp -scp ssl_cert.pem root@<address of unit>:/etc/config/ PuTTY and the PSCP u!lity can be downloaded from h%p://www.chiark.greenend.org.uk/ ~sgtatham/pu%y/download.html. Detailed documenta!on on PSCP can be found at h%ps://the.earth.li/~sgtatham/pu%y/0.67/ htmldoc/Chapter5.html. 14.8.4. Launching the HTTPS server The easiest way to enable the HTTPS server is from the web Management Console. · click the appropriate checkbox in Network > Services > HTTPS Server. The HTTPS server will now be ac!vated (assuming ssl_key.pem and ssl_cert.pem exist in the /etc/config/). Alterna!vely, inetd can be configured to launch the secure fnord server from the command line of the unit as follows. · Edit the inetd configura!on file. From the unit command line: # vi /etc/config/inetd.conf · Append a line: 443 stream tcp nowait root sslwrap -cert /etc/config/ssl_cert.pem -key /etc/config/ssl_key.pem -exec /bin/httpd /home/httpd" · Save the file. · Signal inetd of the configura!on change: # kill -HUP `cat /var/run/inetd.pid` The HTTPS server should now be accessible from a web client at a URL similar to this: https://common-name-of-unit/. 14.9. Power strip control The console server supports a growing list of remote power-control devices (RPCs) which can be configured using the Management Console as described in chapter 7. These RPCs are controlled using the open source PowerMan and Network UPS Tools and with Opengear's Opengear User Manual. Page 326. pmpower u!lity. 14.9.1. the PowerMan tool PowerMan provides power management in a data center or compute cluster environment. It performs opera!ons such as power on, power off, and power cycle via remote power controller (RPC) devices. The powerman man page is not shipped with Opengear hardware. It is reproduced below. Synopsis powerman | pm [-options][targets] op"ons notes regarding targets -1 --on -0 --off power on targets. power off targets. -c --cycle Power cycle targets. -r --reset -f --flash -u --unflash Assert hardware reset for targets (if implemented by RPC). Turn beacon on for targets (if implemented by RPC). Turn beacon off for targets (if implemented by RPC). -l --list -q --query List available targets. If possible, output will be compressed into a host range (see target specifica"on below). Query plug status of targets. If none specified, query all targets. Status is not cached; each !me this op!on is used, powerman queries the appropriate RPC's. Targets connected to RPC's that could not be contacted (e.g. due to network failure) are reported as status "unknown". If possible, output will be compressed into host ranges. -n --node -b --beacon Query node power status of targets (if implemented by RPC). If no targets specified, query all targets. In this context, a node in the off state could be on at the plug but opera!ng in standby power mode. Query beacon status (if implemented by RPC). If no targets are specified, query all targets. -t --temp Query node temperature (if implemented by RPC). If no targets are specified, query all targets. Temperature informa!on is not interpreted by powerman and is reported as received from the RPC on one line per target, prefixed by target name. -h --help Display op!on summary. -L --license Show powerman license informa!on. -d --des!na!on host[:port]. Connect to a powerman daemon on non-default host and op!onally port. -V --version -D --device -T --telemetry Display the powerman version number and exit. Displays RPC status informa!on. If targets are specified, only RPC's matching the target list is displayed. Causes RPC telemetry informa!on to be displayed as commands are processed. Useful for debugging device scripts. -x --exprange Expand host ranges in query responses. For more details see h%p://linux.die.net/man/1/powerman. Opengear User Manual. Page 327. Target specifica"on powerman target hostnames may be specified as comma separated or space separated hostnames or host ranges. Host ranges are of the general form: prefix[n-m,l-k,...] where n < m and l < k, etc. This form should not be confused with regular expression character classes, which are also denoted by []. For example, foo[19] does not represent foo1 or foo9, but rather represents a degenerate range: foo19. This range syntax is meant only as a convenience on clusters with a prefix NN naming conven!on and specifica!on of ranges should not be considered necessary -- the list foo1,foo9 could be specified as such, or by the range foo[1,9]. Some examples of powerman targets follow. Power on hosts bar,baz,foo01,foo02,...,foo05: powerman --on bar baz foo[01-05] Power on hosts bar,foo7,foo9,foo10: powerman --on bar,foo[7,9-10] Power on foo0,foo4,foo5: powerman --on foo[0,4-5] As a reminder to the reader, some shells will interpret brackets -- [ and ] -- for pa%ern matching. Depending on your shell, it may be necessary to enclose ranged lists within quotes. For example, in tcsh, the last example above should be executed as: powerman --on "foo[0,4-5]" 14.9.2. The pmpower tool The pmpower u!lity is a high level tool for manipula!ng remote preconfigured power devices connected to the console server either via a serial or network connec!on. The PDU UPS and IPMI power devices are variously controlled using the open source PowerMan, IPMItool or Network UPS Tools and Opengear's pmpower u!lity arches over these tools so the devices can be controlled through the one command line: Synopsis pmpower [-?h] [-l device | -r host] [-o outlet] [-u username]\ [-p password] action op"ons -? -h -/ -o -r -u -p on off notes This help message. The serial port to use. The outlet on the power target to apply to. The remote host address for the power target Override the configured username. Override the configured password. This ac"on switches the specified device or outlet(s) on. This ac"on switches the specified device or outlet(s) off. Opengear User Manual. Page 328. cycle status Examples: This ac"on switches the specified device or outlet(s) off and on again. This ac"on retrieves the current status of the device or outlet. To turn outlet 4 of the power device connected to serial port 2 on: # pmpower -l port02 -o 4 on To turn an IPMI device off located at IP address 192.168.1.100 where the username is root and the password is calvin: # pmpower -r 192.168.1.100 -u root -p calvin off Default system Power Device ac!ons are specified in /etc/powerstrips.xml. Custom Power Devices can be added in /etc/config/powerstrips.xml. If an ac!on is a%empted which has not been configured for a specific Power Device pmpower will exit with an error. 14.9.3. Adding new RPC devices There are a number of simple paths to adding support for new RPC devices. The first is to have scripts to support the par!cular RPC included in either the open source PowerMan project -- h%ps://code.google.com/archive/p/powerman/ -- or the open source NUT UPS Tools project -- h%p://networkupstools.org/. The PowerMan device specifica!ons are rather weird and it is suggested that you leave the actual wri!ng of these scripts to the PowerMan authors. However documenta!on on how they work can be found at h%p://linux.die.net/man/5/powerman.dev. The Network UPS Tools (NUT) project has moved on from its UPS management origins to also cover SNMP PDUs (and embrace PowerMan). Opengear progressively includes the updated PowerMan and NUT build into the console server firmware releases. The second path is to directly add support for the new RPC devices (or to customize the exis!ng RPC device support) on your par!cular console server. The Manage > Power page uses informa!on contained in /etc/powerstrips.xml to configure and control devices a%ached to a serial port. The configura!on also looks for (and loads) /etc/config/ powerstrips.xml if it exists. You can add support for more devices by pu$ng defini!ons for them into /etc/config/ powerstrips.xml. This file can be created on a host system and copied to the Management Console device using scp. Alterna!vely, login to the Management Console and use ftp or wget to transfer files. Here is a brief descrip!on of the elements of the XML entries in /etc/config/ powerstrips.xml. <powerstrip> <id>Name or ID of the device support</id> <outlet port="port-id-1">Display Port 1 in menu</outlet> <outlet port="port-id-2">Display Port 2 in menu</outlet> ... <on>script to turn power on</on> Opengear User Manual. Page 329. <off>script to power off</off> <cycle>script to cycle power</cycle> <status>script to write power status to /var/run/power-status</status> <speed>baud rate</speed> <charsize>character size</charsize> <stop>stop bits</stop> <parity>parity setting</parity> </powerstrip> The id appears on the web page in the list of available devices types to configure. The outlets describe targets that the scripts can control. For example a power control board may control several different outlets. The port-id is the na!ve name for iden!fying the outlet. This value will be passed to the scripts in the environment variable outlet, allowing the script to address the correct outlet. There are four possible scripts: on, off, cycle and status. When a script is run, it's standard input and output is redirected to the appropriate serial port. The script receives the outlet and port in the outlet and port environment variables respec!vely. The script can be anything that can be executed within the shell. All of the exis!ng scripts in /etc/powerstrips.xml use the pmchat u!lity. pmchat works just like the standard unix chat program, only it ensures interopera!on with the port manager. The final op!ons, speed, charsize, stop and parity define the recommended or default se$ngs for the a%ached device. 14.10. IPMItool The console server includes the ipmitool u!lity for managing and configuring devices that support the Intelligent Pla*orm Management Interface (IPMI) versions 1.5 and 2.0. IPMI is an open standard for monitoring, logging, recovery, inventory, and control of hardware that is implemented independent of the main CPU, BIOS, and OS. The service processor (or Baseboard Management Controller, BMC) is the brain behind pla*orm management and its primary purpose is to handle the autonomous sensor monitoring and event logging features. The ipmitool program provides a simple command-line interface to this BMC. It features the ability to read sensor data repository (SDR) and print sensor values, display the contents of the System Event Log (SEL), print Field Replaceable Unit (FRU) inventory informa!on, read and set LAN configura!on parameters, and perform remote chassis power control. The ipmitools man page is not shipped with Opengear hardware. It is reproduced below. Synopsis ipmitool [-c|-h|-v|-V] -I open <command> ipmitool [-c|-h|-v|-V] -I lan -H <hostname> [-p <port>] Opengear User Manual. Page 330. [-U <username>] [-A <authtype>] [-L <privlvl>] [-a|-E|-P|-f <password>] [-o <oemtype>] <command> ipmitool [-c|-h|-v|-V] -I lanplus -H <hostname> [-p <port>] [-U <username>] [-L <privlvl>] [-a|-E|-P|-f <password>] [-o <oemtype>] [-C <ciphersuite>] <command> Descrip"on This program lets you manage Intelligent Pla*orm Management Interface (IPMI) func!ons of either the local system, via a kernel device driver, or a remote system, using IPMI V1.5 and IPMI v2.0. These func!ons include prin!ng FRU informa!on, LAN configura!on, sensor readings, and remote chassis power control. IPMI management of a local system interface requires a compa!ble IPMI kernel driver to be installed and configured. On Linux this driver is called OpenIPMI and it is included in standard distribu!ons. On Solaris this driver is called BMC and is included in Solaris 10. Management of a remote sta!on requires the IPMI-over-LAN interface to be enabled and configured. Depending on the par!cular requirements of each system it may be possible to enable the LAN interface using ipmitool over the system interface. Op"ons op"on variable notes -a Prompt for the remote server password. -A <authtype> Present output in CSV (comma separated variable) format. This is not available with all commands. -c -C <ciphersuite> The remote server authen!ca!on, integrity, and encryp!on algorithms to use for IPMIv2 lanplus connec!ons. See table 22-19 in the IPMIv2 specifica!on. The default is 3 which specifies RAKPHMAC-SHA1 authen!ca!on, HMAC-SHA1-96 integrity, and AESCBC-128 encryp!on algorithms. -E The remote server password is specified by the environment variable IPMI_PASSWORD. -f <password_file> Specifies a file containing the remote server password. If this op!on is absent, or if password_file is empty, the password will default to NULL. -h -H <address> Get basic usage help from the command line. Remote server address, can be IP address or hostname. This op!on is required for lan and lanplus interfaces. Opengear User Manual. Page 331. -I <interface> Selects IPMI interface to use. Supported interfaces that are compiled in are visible in the usage help output. -L <privlvl> Force session privilege level. Can be CALLBACK, USER, OPERATOR, and ADMIN. Default is ADMIN. -m <local_address> Set the local IPMB address. The default is 0x20 and there should be no need to change it for normal opera!on. -o <oemtype> Select OEM type to support. This usually involves minor hacks in place in the code to work around quirks in various BMCs from various manufacturers. Use -o list to see a list of current supported OEM types. -p <port> Remote server UDP port to connect to. Default is 623. -P <password> Remote server password is specified on the command line. If supported it will be obscured in the process list. Note! Specifying the password as a command line op!on is not recommended. -t <target_address> Bridge IPMI requests to the remote target address. -U <username> Remote server username, default is NULL user. -v Increase verbose output level. This op!on may be specified mul!ple !mes to increase the level of debug output. If given three !mes you will get hexdumps of all incoming and outgoing packets. -V Display version informa!on. If no password method is specified then ipmitool will prompt the user for a password. If no password is entered at the prompt, the remote server password will default to NULL. Security The ipmitool documenta!on highlights that there are several security issues to be considered before enabling the IPMI LAN interface. A remote sta!on has the ability to control a system's power state as well as being able to gather certain pla*orm informa!on. To reduce vulnerability it is strongly advised that the IPMI LAN interface only be enabled in 'trusted' environments where system security is not an issue or where there is a dedicated secure 'management network' or access has been provided through an console server. Further it is strongly advised that not enable IPMI for remote access without se$ng a password. That that password should not be the same as any other password on that system. When an IPMI password is changed on a remote machine with the IPMIv1.5 lan interface the new password is sent across the network as clear text. This could be observed and then used to a%ack the remote system. It is thus recommended that IPMI password management only be done over IPMIv2.0 lanplus interface or the system interface on the local sta!on. For IPMI v1.5, the maximum password length is 16 characters. Longer passwords are truncated. For IPMI v2.0, the maximum password length is 20 characters. Longer passwords are truncated. Commands command notes help This can be used to get command-line help on ipmitool commands. It may also be placed at the end of commands to get op!on usage help. raw Send a RAW IPMI request and print response Opengear User Manual. Page 332. lan chassis* event mc sdr sensor fru sel pef sol isol user channel session exec set Configure LAN Channels Get chassis status and set power state Send pre-defined events to MC Management Controller status and global enables Print Sensor Data Repository entries and readings Print detailed sensor informa!on Print built-in FRU and scan SDR for FRU locators Print System Event Log (SEL) Configure Pla*orm Event Filtering (PEF) Configure IPMIv2.0 Serial-over-LAN Configure IPMIv1.5 Serial-over-LAN Configure Management Controller users Configure Management Controller channels Print session informa!on Run list of commands from file Set run!me variable for shell and exec *chassis commands: status, power, iden!fy, policy, restart_cause, poh, bootdev. chassis power commands: status, on, off, cycle, reset, diag, so&. More details on ipmitools are availalbe at the project site, h%ps://sourceforge.net/projects/ ipmitool/. 14.11. Custom development kit (CDK) As detailed in this manual, customers can copy scripts, binaries and configura!on files directly to the console server. Opengear also freely provides a development kit which allows changes to be made to the so&ware in console server firmware image. The customer can use the CDK to: · generate a firmware image without certain programs, such as telnet, which may be banned by company policy. · generate an image with new programs, such as custom Nagios plug-in binaries or company specific binary u!li!es. · generate an image with custom defaults e.g. it may be required that the console server be configured to have a specific default serial port profile which is reverted to even in event of a factory reset · place configura!on files into the firmware image, which cannot then be modified. For example # /bin/config -set= tools updates the configura!on files in /etc/config which are read/write, whereas the files in /etc are read only and cannot be modified. The CDK essen!ally provides a snapshot of the Opengear build process (taken a&er the programs have been compiled and copied to a temporary directory, romfs) just before the Opengear User Manual. Page 333. compressed file systems are generated. You can obtain a copy of the Opengear CDK for the par!cular appliance you are working with from &p://&p.opengear.com/cdk. Further informa!on is avalable at h%p://opengear.com/ faq284.html. Note: the CDK is free, however Opengear does not provide free technical support for systems modified using the CDK and any changes are the responsibility of the user. 14.12. Scripts for managing slaves When the console servers are cascaded the Master is in control of the serial ports on the Slaves, and the Master's Management Console provides a consolidated view of the se$ngs for its own and all the Slave's serial ports. However the Master does not provide a fully consolidated view. Status > Ac"ve Users only displays those users ac!ve on the Master's ports. You will need to write a custom bash script that parses the port logs if you want to find out who's logged in to cascaded serial ports from the master. You will probably also want to enable remote or USB logging, as local logs only buffer 8K of data and don't persist between reboots. This script would, for example, parse each port log file line by line Each !me it sees LOGIN: username, it adds username to the list of connected users for that port. Each !me it sees LOGOUT: username, it removes it from the list. The list can then be nicely forma%ed and displayed. It's also possible to run this as a CGI script on the remote log server. To enable log storage and connec!on logging: · select Alerts & Logging > Port Log. · configure log storage. · select Serial & Network > Serial Port. · Edit the serial port(s). · Under Console Server, select Logging Level 1. · click Apply. Note: a useful tutorial on crea#ng a bash script CGI is at h"p://yolinux.com/TUTORIALS/ LinuxTutorialCgiShellScript.html. Similarly the Master maintains a view of the status of the slaves: · select Status > Support Report. · scroll down to Processes. · look for /bin/ssh -MN -o ControlPath=/var/run/cascade/%h slavename. These are the slaves that are connected Note: the end of the Slaves' names will be truncated, so the first 5 characters must be unique Opengear User Manual. Page 334. Alterna!vely, you can write a custom CGI script as described above. The currently connected Slaves can be determined by running ls /var/run/cascade and the configured slaves can be displayed by running config -g config.cascade.slaves. 14.13. SMS server tools Firmware releases v3.1 and later include the SMS Server Tools so&ware which provides an SMS Gateway which can send and receive short messages through GSM modems and mobile phones. You can send short messages by simply storing text files into a special spool directory. The program monitors this directory and sends new files automa!cally. It also stores received short messages into another directory as text files. Binary messages (including Unicode text) are also supported, for example ring tone messages. It's also possible to send a WAP Push message to a WAP- or MMS-capable mobile phone. The program can be run as an SMS daemon which can be started automa!cally when the opera!ng system starts. High availability can be ensured by using mul!ple GSM devices (currently up to 64). The program can run other external programs or scripts a&er events like recep!on of a new message, successful sending and also when the program detects a problem. These programs can inspect the related text files and perform automa!c ac!ons The SMS Server Tools so&ware needs a GSM modem (or mobile phone) with SMS command set according to the European specifica!ons GSM 07.05 (=ETSI TS 300 585) and GSM 03.38 (=ETSI TS 100 900). The AT command set is supported. Devices can be connected with serial port, infrared or USB. For more informa!on see h%p://smstools3.kekekasvi.com/ or the online Opengear FAQ. 14.14. Mul"cast By default, all Opengear console servers come with Mul!cas!ng enabled. Mul!cas!ng provides Opengear products with the ability to simultaneously transmit informa!on from a single device to a select group of hosts. With firmware releases v3.1 and later, mul!cas!ng can be disabled and re-enabled from the command line. To disable mul!cas!ng type: ifconfig eth0 -multicast To re-enable mul!cas!ng from the command line type: ifconfig eth0 multicast IPv6 may need to be restarted when toggling between mul!cast states. 14.15. Bulk provisioning Opengear appliances include wizard scripts to facilitate configura!on and deployment en masse. These wizards operate at the command line level, so knowledge of the Linux command Opengear User Manual. Page 335. line and shell scrip!ng is useful, but not necessary they aim to be user-friendly enough for remote hands to manage. This bulk provisioning feature is supported by firmware version 3.9.1 or later, and Lighthouse version 4.4.0 and later (op!onal). Both the bulk provisioning of Opengear appliances and bulk enrollment of these appliances into Lighthouse central management system(s) is supported. These features may be used separately or in conjunc!on. Using this method, an Opengear appliance can be fully configured and enrolled into Lighthouse with minimal interac!on, in under 5 minutes. The basic steps are: · Configure an individual golden master appliance with the baseline configura!on shared by all Opengear appliances. This may be a minimal configura!on if the installs are quite diverse, or a complete configura!on when dealing with replicated installs. · Use make-template to turn the golden master's ac!ve configura!on into a template configura!on that may be applied to other appliances. · Create an OPG backup of the templated golden master appliance. · Restore this configura!on to each target devices via the CLI, web UI or using a USB thumb drive. · Login via the CLI to complete configura!on using setup-wizard. · (Op!onal) On Lighthouse, use enrollment-wizard to automa!cally place appliances under management. This may be local/routable appliances, or remote appliances that have automa!cally Call Home using callhome-wizard. Steps 5 and 6 may be reversed for remote setup via Lighthouse. Full details for the above steps can be found in the Knowledge Base 14.16. Zero touch provisioning Zero Touch Provisioning (ZTP) was introduced with firmware release 3.15.1 to allow Opengear appliances to be provisioned during their ini!al boot from a DHCP server. 14.16.1.Prepara"on These are typical steps for configura!on over a trusted network: · Configure a same-model Opengear device. · Op!onally use the Bulk Provisioning wizard scripts to remove any appliance-specific se$ngs (that is, create a template configura!on) and/or prepare the configura!on for automated Lighthouse enrollment. See chapter 14.15. · Save the configura!on as an Opengear backup (.opg) file under System > Configura"on Backup in the web UI, or via config -e in the CLI. Alterna!vely, you can save the XML configura!on as a file ending in .xml. · Publish the .opg or .xml file on a fileserver that understands one of the HTTPS, HTTP, FTP or TFTP protocols. · Configure your DHCP server to include a vendor specific op!on for Opengear devices. The Opengear User Manual. Page 336. op!on text should be a URL to the loca!on of the .opg or .xml file. The op!on text should not exceed 250 characters in length. It must end in either .opg or .xml. · Connect a new Opengear device (either at defaults from the factory, or config erased) to the network and apply power. Note: it may take up to 5 minutes for the device to find the .opg or .xml file via DHCP, download, install the file and reboot itself. 14.16.2.Example ISC DHCP server configura"on The following is an example ISC DHCP server configura!on fragment for serving an .opg configura!on image: option space opengear code width 1 length width 1; option opengear.config-url code 1 = text; class "opengear-ztp" { match if option vendor-class-identifier ~~ "^Opengear/"; vendor-option-space opengear; option opengear.config-url "https://example.com/opg/$ {class}.opg"; } For other DHCP servers, please consult their documenta!on on specifying vendor specific op!on fields. We use sub-op!on 1 to hold the URL text. 14.16.3.Setup for an untrusted LAN If network security is a concern, and you can have remote hands insert a trusted USB flash drive into the Opengear device during provisioning, then follows are a summary of the steps required for deploying configura!on in an untrusted network: · Generate an X.509 cer!ficate for the client. Place it and its private key file onto a USB flash drive (concatenated as a single file, client.pem). · Set up a HTTPS server that restricts access to the .opg or .xml file for HTTPS onnec!ons providing the client cer!ficate. · Put a copy of the CA cert (that signed the HTTP server's cer!ficate) onto the USB flash drive as well (ca-bundle.crt). · Insert the USB flash drive into the Opengear device before a$aching power or network. · Con!nue with the steps above, but using only an h%ps URL. 14.16.4.How it works This sec!on explains in detail how the Opengear device uses DHCP to obtain its ini!al configura!on. First, an Opengear console manager is either configured or unconfigured. ZTP needs it to be in an unconfigured state, which is only obtained in the following ways: Opengear User Manual. Page 337. · Firmware programming at factory. · Pressing the Config Erase bu%on twice during opera!on. · Selec!ng Config Erase under System > Administra"on in the web UI, and reboo!ng. · Crea!ng the file /etc/config/.init and then reboo!ng. When an unconfigured Opengear device boots, it performs these steps to find a configura!on: · the Opengear device transmits a DHCP DISCOVER request onto its primary Network Interface (WAN). This DHCP request carries a Vendor Class Iden!fier of the form Opengear/model-name (for example, Opengear/ACM5003-M) and its parameter request list will include op!on 43 (Vendor-Specific Informa!on). · On receipt of a DHCP OFFER, the device will use the informa!on in the offer to assign an IPv4 address to its primary Network Interface, add a default route, and prepare its DNS resolver. · If the offer also contained an op!on 43 with sub-op!on 1, the device interprets the subop!on as a whitespace-separated list of URLs to configura!on files to try to restore. · If an NTP server op!on was provided in the DHCP offer, the system clock is synchronized with the NTP server. · The system now searches all a%ached USB storage devices for two op!onal cer!ficate files. The first file is named ca-bundle.crt and the second one is whichever one of the following filenames is found first: file-name notes client-aabbccddeeff.pem aabbccddeeff is the MAC address of the primary network interface. client-model.pem model is the (vendor class) model name in lowercase. client.pem · If both files -- ca-bundle.crt and client*.pem -- are found, then secure mode is enabled for the next sec!on. Each URL in the list obtained from op!on 43 sub-op!on 1 is tried in sequence un!l one succeeds: · the URL undergoes substring replacement from the following table: sub-string ${mac} ${model} ${class} ${version} replaced by the 12-digit MAC address of the device. the full model name, in lowercase. the firmware hardware class. the firmware version number. example 0013b600b669 acm5504-5-g-w-i ACM550x 3.15.1 · the resul!ng URL must end in .opg or .xml (an op!onal ?query-string is permi%ed). If is doesn't, it is skipped and the next URL is tried. Opengear User Manual. Page 338. · in secure mode, the URL must use the h%ps scheme or it is skipped. · otherwise the available schemes are: h%p, h%ps, *tp, &p, and &ps. · The curl program is used to download the URL. · In secure mode, the server's cer!ficate must validate against the ca-bundle.crt. The (required) client.pem file is provided to authen!cate the client to the server. See the curl documenta!on for the format of these files. · The URL is downloaded. For .opg files, its header is checked to see if it is compa!ble with the current device. For .xml files, a parse check is made. If the check fails, the downloaded file is abandoned and the next URL is tried. · The file is imported into the current configura!on. · The system checks to see if a hostname has been set in the config. If not, it is set to $ {model}-${mac}. · The system checks to see if it is s!ll in an unconfigured state. If it is, then the network interface mode is set to DHCP. This effec!vely forces the system into a configured state, preven!ng a future reboot loop. · The system reboots. Note: If all the URLs were skipped or failed, the system will wait for 30 seconds before retrying again. It will retry all the URLs up to 10 #mes. A(er the 10th retry, the system reboots. If the system has been manually configured in the mean#me, the retries stop and ZTP is disabled. Note: Note: If no op#on 43 is received over DHCP, no URLs are downloaded and no reboots occur: the system must be manually configured. Once configured (manually or by ZTP), an Opengear will no longer request op#on 43 from the DHCP server, and it will ignore any op#on 43 configura#on URLs presented to it. 14.17. Internal storage Some models have an internal USB flash drive, a non-vola!le NAND flash par!!on, or both, which can be used by portmanager for log storage and the TFTP/FTP server for file storage. These storage devices are automa!cally mounted as subdirectories of /var/mnt/. The default directory served by FTP or TFTP is set to the preferred internal storage (if any), otherwise the first detected a%ached USB storage. The loca!on of portmanager logs must be manually configured. 14.17.1.Filesystem loca"on of FTP & TFTP directory product ACM7000 CM7100 IM7200 ACM5500 preferred storage internal flash internal USB flash internal USB flash internal USB flash directory /var/mnt/storage.nvlog/*tpboot/ /var/mnt/storage.usb/*tpboot/ /var/mnt/storage.usb/*tpboot/ /var/mnt/storage.usb/*tpboot/ Opengear User Manual. Page 339. ACM5000-F internal USB flash op!on /var/mnt/storage.usb/*tpboot/ Other products with USB first-a%ached USB storage /var/mnt/storage.usb/*tpboot/ 14.17.2.Filesystem loca"on of portmanager logs port log server type USB flash memory non-vola!le internal storage micros-SD card other (NFS, CIFS, etc) directory /var/mnt/storage.usb /var/mnt/storage.nvlog /var/mnt/storage.sd as explicitly configured 14.17.3.Configuring FTP & TFTP directory The FTP or TFTP services can be configured to serve different directories via the command line. For example: config -s config.services.ftp.directory=/var/mnt/storage.usb/\ my-ftp-dir config -r services The directory will be created if it doesn't already exist. 14.17.4.Moun"ng a preferred USB disk by label Currently, the `first' USB storage device is mounted at /var/mnt/storage.usb by detec!ng the lowest numbered disk par!!on, for example /dev/sda1. This can be constrained to match a par!cular port or a labelled device. · A%ach the USB disk you plan to use. · Look in directories /dev/disk/by-path/ or /dev/disk/by-label/ to find a suitably stable way of iden!fying your disk. · Use the following command to see the current device matching string used: · # config -g config.storage.usb.device · Change the path match with (for example): · # config -s config.storage.usb.device=/dev/disk/by-label/1103 Opengear User Manual. Page 340. Appendix 1. Commands & source code Appendix 1.1.Commands The console server pla*orm is a dedicated Linux computer, op!mized to provide monitoring and secure access to serial and network consoles of cri!cal server systems and their suppor!ng power and networking infrastructure. Opengear console servers are built on the uCLinux distribu!on as developed by the uCLinux project. This is GPL code and the source can be found at h%p://cvs.uclinux.org. Some uCLinux commands have config files that can be altered (for example, portmanager, inetd, init, and sshd). Other commands you can run and do neat stuff with (for example loopback, bash (shell), &p, hwclock, iproute, iptables, netcat, ifconfig, mii-tool, netstat, route, ping, portmap, pppd, routed, setserial, smtpclient, s$y, stunel, tcpdump, (tp, "p, and traceroute). Opengear console servers also ship with Busybox, the `Swiss Army Knife of embedded Linux' which `combines !ny versions of many common UNIX u!li!es into a single small executable.' See h%ps://busybox.net/ for more informa!on. The table below lists most of the standard uCLinux commands (ucl), Busybox commands (bb), and some custom Opengear commands (og), included in the default build tree. The shorthand immediately right of each listed command shows which source is used to run a given command: ucl for uCLinux; bb for Busybox; and og for Opengear-specific commands. The Administrator can use these to configure the console server, and monitor and manage a%ached serial console and host devices. Opengear User Manual. Page 341. command addgroup adduser age%y arp arping bash busybox cat chat chgrp chmod chown config cp date dd deluser df dhcpd discard dmesg echo erase eraseall false find flashw fla*sd &p gen-keys getopt ge%yd grep gunzip gzip hd hostname h%pd hwclock inetd inetd-echo init descrip"on bb Add a group or add a user to a group. bb Add a user. ucl Alterna!ve Linux ge%y. ucl Manipulate the system ARP cache. ucl Send ARP requests/replies. ucl GNU Bourne-Again Shell. bb Swiss army knife of embedded Linux commands. bb Concatenate file(s) and print them to stdout. ucl Useful for interac!ng with a modem connected to stdin/stdout. bb Change file access permissions. bb Change file access permissions. bb Change file access permissions. og Tool to manipulate and query system configura!on from the shell. bb Copy files and directories. bb Print or set the system date and !me. bb Convert and copy a file. bb Delete a user from the system. bb Report file system disk space usage. ucl Dynamic Host Configura!on Protocol server. ucl Network u!lity that listens on the discard port. bb Print or control the kernel ring buffer. bb Print the specified ARGs to stdout. ucl Tool for erasing MTD par!!ons. ucl Tool for erasing en!re MTD par!!ons. bb True and false return an exit status. Zero for true; non-zero for false. ucl Search for files. ucl Write data to individual flash devices. ucl dæmon to save RAM file systems back to FLASH. ucl Internet file transfer program. ucl SSH key genera!on program bb Parses command op!ons. ucl Ge%y dæmon bb Print lines matching a pa%ern. bb Compress or expand files. bb Compress or expand files. ucl ASCII, decimal, hexadecimal, octal dump. bb Get or set hostname or DNS domain name. ucl Listen for incoming HTTP requests. ucl Query and set hardware clock (RTC). ucl Network super-server dæmon. ucl Network echo u!lity. ucl Process control ini!aliza!on. Opengear User Manual. Page 342. ip ucl ipmitool ucl iptables ucl ip6tables ucl iptables-restore ucl iptables-save ucl kill bb ln bb login ucl loopback og loopback1 og loopback2 og loopback8 og loopback16 og loopback48 og ls bb mail ucl mkdir bb mkfs.jffs2 ucl mknod bb more bb mount bb msmtp ucl mv bb nc ucl ne*lash ucl netstat ucl ntpd ucl pgrep ucl pidof ucl ping ucl ping6 ucl pkill ucl pmchat og pmdeny og pminetd og pmloggerd og pmshell og portmanager og portmap ucl pppd ucl ps bb pwd bb reboot bb Show or manipulate rou!ng, devices, policy rou!ng, and tunnels. Linux IPMI manager. Administra!on tool for IPv4 packet filtering and NAT. Administra!on tool for IPv6 packet filtering. Restore IP tables. Save IP tables. Send a signal to a process to end gracefully. Make links between files. Begin session on the system. Loopback diagnos!c command. Loopback diagnos!c command. Loopback diagnos!c command. Loopback diagnos!c command. Loopback diagnos!c command. Loopback diagnos!c command. List directory contents. Send and receive mail. Make directories. Create an MS-DOS file system under Linux. Make block or character special files. File persual filter for crt viewing. Mount a file system. SMTP mail client. Move (rename) files. TCP/IP Swiss army knife. Upgrade firmware on uCLinux pla*orms using the blkmem interface. Print network connec!ons, rou!ng tables, interface sta!s!cs, etc. Network Time Protocol (NTP) dæmon. Display process(es) selected by regex pa%ern. Find the process ID of a running program. Send ICMP ECHO_REQUEST packets to network hosts. IPv6 ping. Sends a signal to process(es) selected by regex pa%ern. Similar command to the standard chat command (via portmanager). Similar to "p or cu but all serial port access is directed via portmanager. Command to handle all serial port access. DARPA port to RPC program number mapper. Point-to-point protocol dæmon. Report a snapshot of the current processes. Print name of current working directory. So& reboot the system. Opengear User Manual. Page 343. rm rmdir routed routef routel rtacct rtmon scp sed setmac setserial sh showmac sleep smbmnt smbmount smbumount snmpd snmptrap sredird ssh ssh-keygen sshd s%y stunnel sync sysctl syslogd tar tc tcpdump telnetd *tp *tpd !p top touch traceroute traceroute6 true umount uname usleep vconfig bb Remove files or directories. bb Remove empty directories. ucl Show or manipulate the IP rou!ng table. ucl IP route tool to flush IPv4 routes. ucl IP route tool to list routes. ucl network sta!s!cs tool. ucl RTnetlink listener. ucl Secure copy (remote file copy program). bb Stream text editor. ucl Sets the MAC address. ucl Sets and reports serial port configura!on. ucl The Bourne shell. ucl Shows the MAC address. bb Delay for a specified amount of !me. ucl Helper u!lity for moun!ng SMB file systems. ucl Mount an SMBFS file system. ucl SMBFS umount for normal users. ucl SNMP dæmon. ucl Sends an SNMP no!fica!on to a manager. ucl RFC2217-compliant serial port redirector. ucl OpenSSH SSH client (remote login program). ucl Authen!ca!on kkey genera!on, management, and conversion. ucl OpenSSH SSH dæmon. ucl Change and print terminal line se$ngs. ucl Universal SSL tunnel. bb Flush file system buffers. ucl Configure kernel parameters at run!me. ucl System logging u!lity. bb The tar archiving u!lity. ucl Show traffic control se$ngs. ucl Dump traffic on a network. ucl Telnet protocol server. ucl Client to transfer a file to or from a *tp server. ucl Trivial file transfer protocol (*tp) server. ucl Simple terminal emulator for connec!ng to modems and serial devices. ucl Provide a view of process ac!vity in real !me. bb Change file !mestamps. ucl Print the route packets take to a network host. ucl Traceroute for IPv6. bb True and false return an exit status. Zero for true; non-zero for false. bb Unmounts file systems. bb Print system informa!on. bb Delay for a specified !me. bb Create and remove virtual ethernet devices. Opengear User Manual. Page 344. vi bb Busybox clone of the VI text editor. w ucl Show who is logged on and what they are doing. zcat bb Iden!cal to gunzip -c. With most of the above commands, the -h or --help argument provides a terse run!me descrip!on of their behavior. More details on the Linux commands can found at h%p://en.tldp.org/HOWTO/HOWTOINDEX/howtos.html and h%p://faqs.org/docs/Linux-HOWTO/Remote-Serial-Console- HOWTO.html. An updated list of the commands in the latest console server build can be found at h%p:// www.opengear.com/faq233.html. Alterna!vely, run ls when /bin/ is the present working directory (pwd) to view all the commands available on your console server. There were a number of Opengear tools listed above, each denoted as og, that make it simple to configure the console server and ensure the changes are stored in the console server's flash memory. These commands are documented in previous chapters and include: · config, which allows manipula!on and querying of the system configura!on from the command line. With config a new configura!on can be ac!vated by running the relevant configurator, which performs the ac!on necessary to make the configura!on changes live. · portmanager, which provides a buffered interface to each serial port. It is supported by the pmchat and pmshell commands which ensure all serial port access is directed via the portmanager. · pmpower, which is a configurable tool for manipula!ng remote power devices that are serially- or network-connected to the console server. · SDT Connector, which is a java client applet that provides point-and-click SSH-tunneled connec!ons to the console server and Managed Devices. There are also a number of other CLI commands related to other open source tools embedded in the console server including: · PowerMan, which provides power management for many preconfigured remote power controller (RPC) devices. For CLI details see h%p://linux.die.net/man/1/powerman. · Network UPS Tools (NUT), which provides reliable monitoring of UPS and PDU hardware and ensure safe shutdowns of the systems which are connected, with a goal to monitor every kind of UPS and PDU. For CLI details see h%p://networkupstools.org/. · Nagios, which is a popular, enterprise-class management tool that provides central monitoring of the hosts and services in distributed networks. For CLI details see h%p:// nagios.org/. The console server also supports GNU bash shell scripts, enabling the Administrator to run custom scripts. GNU bash, version 2.05.0(1)-release (arm-OpenGear-linux-gnu) offers the following shell commands: command alias bg bind arguments [-p] [name[=value] ...] [jobspec ...] [-lpvsPVS] [-m keymap] [-f fi break [n] Opengear User Manual. Page 345. case cd command compgen complete con!nue declare dirs disown echo enable eval exec exit export false fc fg for func!on getopts hash help history if kill local logout popd prin* pushd pwd read readonly select set shi& word in [ [(] pa$ern [| pa$ern]...) command-list ;;]... esac [-L|[-P [-e]] [-@] [directory] [-pVv] command [arguments ...] [op"on] [word] [-abcdefgjksuv] [-o comp-op"on] [-DE] [-A ac"on] [-G globpat] [-W wordlist] [-F func"on] [-C command] [-X filterpat] [-P prefix] [-S suffix] name [name ...] complete -pr [-DE] [name ...] [n] [-aAfFgilnrtux] [-p] [name[=value] ...] [-clpv] [+N | -N] [-ar] [-h] [jobspec ... | pid ... ] [-neE] [arg ...] [-a] [-dnps] [-f filename] [name ...] [arguments] [-cl] [-a name] [command [arguments]] [n] [-fn] [-p] [name[=value]] [-e ename] [-lnr] [first] [last] -s [pat=rep] [command] [jobspec] name [ [in [words ...] ] ; ] do commands; done name { commands ; } or NA optstring name [args] [-r] [-p filename] [-dt] [name] [-dms] [pa$ern] [n] -c -d offset [-anrw] [filename] -ps arg test-commands; then consequent-commands; [elif more-test-commands; then more-consequents;] [else alternate-consequents;] fi [-s sigspec] [-n signum] [-sigspec] jobspec or pid -l|-L [exit_status] [op"on] name[=value] ... [-n] [+N | -N] [-v var] format [arguments] [-n] [+N | -N | dir] [-LP] [-ers] [-a aname] [-d delim] [-i text] [-n nchars] [-N nchars] [-p prompt] [-t "meout] [-u fd] [name ...] [-aAf] [-p] [name[=value]] ... name [in words ...]; do commands; done [--abe0kmnptuvxBCEHPT] [-o op"on-name] [argument ...] [+abe0kmnptuvxBCEHPT] [+o op"on-name] [argument ...] [n] Opengear User Manual. Page 346. shopt source suspend test !me !mes trap true type typeset umask unalias unset un!l variables while [-pqsu] [-o] [optname ...] filename [-f] expr [-lp] [-lp] [arg] [sigspec ...] [-afptP] [name ...] [-afFgrxilnrtux] [-p] [name[=value] ...] [-p] [-S] [mode] [-a] [name ... ] [-fnv] [name] test-commands; do consequent-commands; done variable wait [n] while commands; do commands; done test-commands; do consequent-commands; done Appendix 1.2.Source code Many console server so&ware components are licensed under the GNU General Public License, Version 2, which Opengear supports. A copy of the GNU General Public License is included in Appendix 6: End-user license agreements. A copy is also available at h%p:// gnu.org/licenses/old-licenses/gpl-2.0.html. Opengear will provide source code for any of the components of the so&ware licensed under the GNU General Public License upon request. You may obtain the latest snapshot source code package on a CD by sending a US$5.00 money order or check to: Opengear Support 630 West 9560 South, Suite A Sandy, UT 84070, USA Alternately the complete source code corresponding to each released version is available from us for a period of three years a&er its last shipment. If you would like the source code for an earlier release than the latest current release please write "source for firmware Version x.xx" in the memo line of your payment. This offer is valid to anyone in receipt of this informa!on. The console server also embodies the okvm console management so&ware. This is GPL code and the full source is available from h%p://okvm.sourceforge.net/. The console server BIOS (boot loader code) is a port of uboot which is also a GPL package with source code openly available from h%p://denx.de/wiki/U-Boot/. The console server CGIs (the html code, xml code and web config tools for the Management Console) are proprietary to Opengear. The code will be provided to customers, under NDA. Also built-in to the console server is a Port Manager applica!on and Configura!on tools as documented in Chapters 13 and 14 above. These both are proprietary to Opengear, but open to customers under NDA, as above. Opengear User Manual. Page 347. Appendix 2. Hardware specifica!ons Appendix 2.1.Physical dimensions model ACM5002/3/4(-2) (-M/W/G) ACM5504/8-2/5(-M/G/W/I) ACM7004, ACM7004-2-L (V/A/R/MA/MV/MCR/MCT) IM7216/32/48 IM4208/16/32/48 IM4216-34 CM7116/32/48 W x D x H (mm) W x D x H () weight (kg) weight (lb) 103 x 087 x 28 04.1 x 03.4 x 1.1 1.0 2.2 166 x 102 x 28 06.5 x 03.4 x 1.4 1.8 4.0 130 x 120 x 35 05.1 x 04.8 x 1.4 0.6 1.3 440 x 254 x 45 17.0 x 10.0 x 1.8 432 x 313 x 45 17.0 x 12.0 x 1.8 432 x 313 x 45 17.0 x 12.0 x 1.8 440 x 170 x 45 17.0 x 06.9 x 1.8 4.5 10.0 5.4 11.8 5.4 11.8 4.0 9.0 Appendix 2.2.Opera"ng ranges measure ambient opera!ng temperatures non-opera!ng storage temperatures opera!ng humidity power power consump!on RJ45 serial ports range 5°C 50°C (41°F 122°F) -30°C 60°C (-20°F 140°F) 5% 90% See sec!on 1.2, `Power connec!on', for details All less than 30 W 50 230,400 bps Opengear User Manual. Page 348. DB9 serial port 2400 115,200 bps Appendix 2.3.CPUs model IM7200 series CM7100 series ACM7000 series ACM5000 & ACM5500 series Other models CPU 1 GHz ARM SoC (Marvell 88F6283) 800 MHz ARM SoC (Marvell 88F6W11) 800 MHz ARM SoC (Marvell 88F6W11) Micrel KSZ8692 ARM9 Micrel KS8695P controller Appendix 2.4.Memory & storage model ACM5002/3/4(M/W/G)(-2) ACM5504/8-2/5(-M/G/W/I) ACM7004, ACM7004-2-L (V/A/R/MA/MV/MCR/MCT) IM7216/32/48 IM4208/16/32/48 IM4216-34 CM7116/32/48 RAM (MB) embedded Flash (MB) 32 16 64 16 256 256 Flash storage (GB) 4 4 256 64 16 64 16 16 64 16 16 256 32 4 Appendix 2.5.USB Ports model ACM5002/3/4(M/W/G)(-2) ACM5504/8-2/5(-M/G/W/I) ACM7004, ACM7004-2-L(V/A/R/MA/MV/MCR/MCT) IM7216/32/48 IM4208/16/32/48 & IM4216-34 CM7116/32/48 USB 2.0 2 (and 2 internal) 2 4 3 2 USB 3.0 2 Appendix 2.6.Serial ports model ACM5002 ACM5003-M/W ACM5004(-G/LR)(-2) ACM5004(-G/LR)-I ACM5504-(2/5)-G(-W)-I(-P) ACM5508-2-I/M ACM7004, ACM7004-2-L (V/A/R/MA/MV/MCR/MCT) IM7216-2 Opengear User Manual. Page 349. RJ45 ports DB-9 2 x RS-232 3 x RS-232 4 x RS-232 4 x selectable RS-232/422/485 4 x RS-232 4 x selectable RS-232/422/485 4 x RS-232 RJ45 console 16 x RS-232 1 IM7232-2 IM7248-2 IM4208-2 IM4216-2 & IM4216-34 IM4232-2 IM4248-2 CM7116-2 CM7132-2 CM7148-2 32 x RS-232 1 48 x RS-232 1 8 x RS-232 1 16 x RS-232 1 32 x RS-232 1 48 x RS-232 1 16 x RS-232 1 32 x RS-232 1 48 x RS-232 1 Appendix 2.7.Ethernet ports model ACM5002/3/4(-M/G/LR)(-I) ACM5004-2, ACM5504-2 and ACM5508-2 IM7216/32/48 IM4208/16/32/48-2 IM4216-34 ACM5504-5-G-W-I & ACM5004-5-G-I ACM7004, ACM7004-2-L (V/A/R/MA/MV/MCR/MCT) CM7116/32/48 IM7216/32/48 primary LAN 1 x 100Base-T 2 x 100Base-T 2 x 100Base-T or 2 x SFP 2 x 100Base-T 2 x 100Base-T 1 x 100Base-T 2 x 1000Base-T management LAN 32 x 100Base-T 4 x 100Base-T 2 x 1000Base-T 2 x 1000Base-T Opengear User Manual. Page 350. Appendix 3. Safety & cer!fica!ons Appendix 3.1.Safety precau"ons Take care to follow the safety precau!ons below when installing and opera!ng the console server: · Do not remove the metal covers. There are no operator serviceable components inside. Opening or removing the cover may expose you to dangerous voltage which may cause fire or electric shock. Refer all service to Opengear qualified personnel. · To avoid electric shock, the power cord protec!ve grounding conductor must be connected through to ground. · Always pull on the plug, not the cable, when disconnec!ng the power cord from the socket. · Do not connect or disconnect the console server during an electrical storm. A surge suppressor or UPS to protect the equipment from transients is also recommended. Appendix 3.2.FCC warning statement This device complies with Part 15 of the FCC rules. Opera!on of this device is subject to the following condi!ons: 1. This device may not cause harmful interference, and Opengear User Manual. Page 351. 2. this device must accept any interference that may cause undesired opera!on. Appendix 3.3.WEEE statement The symbol on the product or its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collec!on point for the recycling of waste electrical and electronic equipment. The separate collec!on and recycling of your waste equipment at the !me of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more informa!on about where you can drop off your waste for recycling, please contact your local authority, or where you purchased your product. Opengear User Manual. Page 352. Appendix 4. Connec!vity, TCP ports & serial I/O Pin-out standards exist for DB9 and DB25 connectors. There are, however, no pin-out standards for serial connec!vity using RJ45 connectors. Most console servers, seriallymanaged servers, routers, switches and power devices adopt their own unique pin-outs. Consequently, custom connectors and cables may be required to interconnect your console server. Appendix 4.1.Serial port pinouts Opengear's console servers come with one to forty-eight serial connectors (notated SERIAL or SERIAL PORTS) for the RS232 serial ports. · The RJ45 serial ports are located on the front face of the ACM5000 and ACM5500; on the front panel of the rack mount IM4200; and on the rear panel of the rack-mount IM7200 and CM7100. · The CM7100, ACM5000, ACM5500 and ACM7000 models and the IM4216-34 have Cisco Straight serial pinouts on their RJ45 connectors. · The other IM4200 console servers are available with a selec!on of alternate RJ45 pinouts (which must be specified in the part number at the !me of order). The IM4208-2, IM4216-2, IM4232-2 and IM4248-2 console servers have three RJ45 pinout configura!ons available: Opengear Classic, Cisco Straight or Cyclades/Cisco Rolled. · The IM7200 has so&ware selectable Cisco Straight or Cisco Rolled RJ45. Opengear User Manual. Page 353. Cisco Straight RJ45 pinout (op"on -X2) Straight through RJ-45 cable to equipment such as Cisco, Juniper, SUN, and more. pin signal defini"on direc"on 1 CTS clear to send input 2 DSR data set ready input 3 RXD receive data input 4 GND signal ground n/a 5 GND signal ground n/a 6 TXD transmit data output 7 DTR data terminal ready output 8 RTS request to send output Opengear Classic (X0) RJ45 pinout This is the same RJ45 pinout as the Avocent/Equinox brand console server. pin signal defini"on direc"on 1 RTS clear to send input 2 DSR data set ready input 3 DCD receive data input 4 RXD signal ground n/a 5 TXD signal ground n/a 6 GND transmit data output 7 DTR data terminal ready output 8 CTS request to send output Cisco Roles RJ45 pinout (op!on -X1) Easy to replace Avocent/Cyclades products, for use with rolled RJ-45 cable. pin signal defini"on direc"on 1 RTS request to send output 2 DTR data terminal ready output 3 TXD transmit data output 4 GND signal ground n/a 5 CTS clear to send input 6 RXD receive data input 7 DCD data carrier detect input 8 DSR data set ready input Appendix 4.2.Local console port Console servers with a dedicated LOCAL console/modem port use a standard DB9 connector for this port. To connect to the LOCAL modem/console port on the console servers using a computer or terminal device use the 319001 or 319003 adaptors with standard UTP Cat 5 cable. Opengear User Manual. Page 354. To connect the LOCAL console ports to modems (for out of band access) use the 319004 adaptor with standard UTP Cat 5 cable. Each Opengear console server is supplied with UTP Cat 5 cables. Appendix 4.3.RS232 standard pinouts The RS232 pinout standards for the DB9 and DB25 connectors are tabled below. db25 signal db9 1 2 TXD 3 3 RXD 2 4 RTS 7 5 CTS 8 6 DSR 6 7 GND 5 8 CD 1 9 10 11 12 SCF 13 SCB 14 SBA 15 DB 16 SBB 17 DD 18 19 SCA 20 DTR 4 21 CG 22 9 23 CH/CI 24 DA 25 defini"on protec!ve ground transmi%ed data received data request to send clear to send data set ready signal ground received line signal detector reserved for data set tes!ng reserved for data set tes!ng unassigned secondary received line signal detector secondary clear to send secondary transmi%ed data transmission signal !ming secondary received data receiver signal element !ming unassigned secondary request to send data terminal ready signal quality detector ring indicator data signal rate selector transmit signal element !ming unassigned 25-pin DB25 female 25-pin DB25 male 9-pin DB25 female 9-pin DB25 male 8-pin RJ45 Appendix 4.4.Connectors included in console server The ACM5000, ACM5500, ACM7000, CM7100 and IM7200 families, and the IM4208/16/32/48-X2 and IM4216-34-X2, have the Cisco pinout by default and ship with cross-over/straight RJ45-DB9 connectors. DB9F-RJ45S straight connector RJ-45 1 CTS 2 DCD 3 RXD 4 wiring table ---------------------------------------------------------- N/C DB9 F 8 CTS 1 DCD 2 RXD Opengear User Manual. Page 355. part #319014 5 GND 6 TXD 7 DTR 8 RTS ----------------------------------------------------------------------------- 5 GND 3 TXD 4 DTR 7 RTS DB9F-RJ45S cross-over connector part #319015 RJ-45 1 CTS 2 DCD 3 RXD 4 5 GND 6 TXD 7 DTR 8 RTS wiring table ---------------------------------------------------------- N/C ----------------------------------------------------|------------------|------------------------ DB9 F 7 RTS 4 DTR 3 TXD 5 GND 2 RXD 1 DCD 6 DSR 8 CTS The IM4208/16/32/48-X0 all have the Opengear Classic pinout and ship with a cross-over and a straight RJ45-DB9 connector for connec!ng to other vendor's products. DB9F-RJ45S straight connector part #319000 RJ-45 1 RTS 2 DSR 3 DCD 4 RXD 5 TXD 6 GND 7 DTR 8 CTS wiring table --------------------------------------------------------------------------------------------------------------------------------------------------------- DB9 F 7 RTS 6 DSR 1 DCD 2 RXD 3 TXD 5 GND 4 DTR 8 CTS 9 CTS DB9F-RJ45S cross-over connector part #319001 RJ-45 1 RTS 2 DSR 3 DCD 4 RXD 5 TXD 6 GND 7 DTR 7 DTR 8 CTS wiring table DB9 F -------------------- 8 CTS -------------------- 4 DTR -------------------- 4 DTR -------------------- 3 TXD -------------------- 2 RXD -------------------- 5 GND -------------------- 6 DSR -------------------- 1 DCD -------------------- 7 RTS 9 RI Appendix 4.5.Other available connectors & adapters Opengear also supplies a range of cables and adapters that will enable you to easily connect to the more popular servers and network appliances. More detailed informa!on can be found online at h%ps://opengear.zendesk.com/forums/21087337-cabling. Opengear User Manual. Page 356. Appendix 4.5.1.For Local/Console connec"on: These adapters connect the console server LOCAL/Console port (via standard UTP Cat 5 cable) to modem devices (for out-of-band access): 319000 DB9F to RJ45 straight console server LOCAL Console Port to Modem. 319002 DB25M to RJ45 straight console server LOCAL Console Port to Modem. For console server Serial Port connec!on, the Opengear connectors and adapters detailed below are specified to work with standard UTP Cat 5 cable. Appendix 4.5.2.For console servers with Cisco pinouts 319014 DB9F to RJ45 straight console server with Cisco pinout to IP Power and other serial device. 319015 DB9F to RJ45 crossover DCE Adapter -- console server with Cisco pinout to X86 and other. 319016 DB9M to RJ45 straight DTE Adapter -- console server with Cisco pinout to Netscreen and Dell. 319004 DB9M to RJ45 straight DTE Adapter -- console server OOB modem connec!on. Appendix 4.5.3.For console servers with Opengear Classic pinouts 319000 DB9F to RJ45 straight Console server with Opengear classic pinout to IP Power and other serial device. 319001 DB9F to RJ45 crossover DCE Adapter -- console server with Opengear classic pinout to X86 and other. 319002 DB25M to RJ45 straight DTE Adapter for console server with Opengear classic pinout. 319003 DB25M to RJ45 crossover DCE Adapter -- console server with Opengear classic pinout to Sun and other. 319004 DB9M to RJ45 straight DTE Adapter -- console server with Opengear classic pinout to Netscreen and Dell; and OOB modem connec!on. 319005 DB25F to RJ45 crossover DCE Adapter -- console server with Opengear classic pinout to Cisco 7200 AUX. 440016 5& Cat5 RJ-45 to RJ-45 cables. Appendix 4.5.4.Extension cables 449016 RJ-45 plug to RJ-45 jack Adapter for console server with Opengear classic pinout to Cisco console (and to Netscreen with reversing cable). 449017 RJ-45 plug to RJ-45 jack Adapter for console server with Opengear classic pinout to Rackable Systems console. Opengear User Manual. Page 357. Appendix 4.6.TCP & UDB port numbers Port numbers are divided into three ranges: Well Known Ports, Registered Ports and Dynamic & Private Ports. Well Known Ports are those from 0 through 1023. Registered Ports are those from 1024 through 49151. Dynamic & Private Ports are those from 49152 through 65535. Well Known Ports are assigned by IANA, and on most systems, can only be used by system processes or by programs executed by privileged users. The table below shows some of the well-known port numbers. For more details, please visit the IANA website: h%p:// www.iana.org/assignments/port-numbers. port number protocol 21 FTP (File Transfer Protocol) 22 SSH (Secure Shell) 23 Telnet 25 SMTP (Simple Mail Transfer Protocol) 37 Time 39 RLP (Resource Loca!on Protocol) 49 TACACS, TACACS+ 53 DNS tcp/udp TCP TCP TCP TCP TCP, UDP UDP UDP UDP Appendix 4.7.Serial port pinouts: ACM5004-20-I, ACM5504-G-I, & ACM5508-2-I Each serial RJ-45 ports on these models can be so&ware selected to be RS-232, RS-422 or RS-485. · For RS232 they have the Cisco pinout. · For RS-422 mode it's 4-wire full duplex transmit on TX+/TX- pair, receive on RX+/RX- pair with the following pinout. · For RS-485 it's 2-wire half duplex. For the RS-485 op!on, to provide half duplex `party-line' communica!ons over a 2-wire bus (D+/D-), two short cable loops are required between the RX+/TX+ pins (pins 1 and 6) and RX-/TX- pins (pins 3 and 8) on the serial RJ-45 cable connector. This is because the -I model uses universal differen!al transceivers that support 4-wire (RS-422) and 2-wire (RS-485) opera!on. In RS-485 mode, the -I model listens on the 2-wire bus for receive data un!l it is required to Opengear User Manual. Page 358. send data. In RS-485 send mode it stops receiving, enables its transmi%ers when there is data to be sent, transmits the data and returns to receive mode. This eliminates the possibility of collisions with other devices which share the RS-485 bus and avoids receiving bogus stale echoed data. pin signal direc"on rs422 signal descrip"on 1 RX+ input receive data 2 N/C receive data 3 RX- input 4 GND 5 GND 6 TX+ output transmit data 7 N/C 8 N/C output transmit data Opengear User Manual. Page 359. Appendix 5. Terminology term 3G AES APN Authen!ca!on BIOS meaning Third-genera!on cellular technology. The standards that determine 3G call for greater bandwidth and higher speeds for cellular networks. The Advanced Encryp!on Standard (AES) is a new block cipher standard to replace DES, developed by NIST, the US Na!onal Ins!tute of Standards and Technology. AES ciphers use a 128-bit block and 128-, 192-, or 256-bit keys. The larger block size helps resist birthday a%acks while the large key size prevents brute force a%acks. Access Point Name (APN) is used by carriers to iden!fy an IP packet data network that a mobile data user wants to communicate with and the type of wireless service. Authen!ca!on is the technique by which a process verifies that its communica!on partner is who it is supposed to be and not an imposter. Authen!ca!on confirms that data is sent to the intended recipient and assures the recipient that the data originated from the expected sender and has not been altered on route. Basic Input/Output System is the built-in so&ware in a computer that are executed on startup (boot) and that determine what the computer can do without accessing programs from a disk. On PCs, the BIOS contains all the code required to control the keyboard, display screen, disk drives, serial communica!ons, and a number of miscellaneous func!ons. Opengear User Manual. Page 360. Bonding BOOTP Cer!ficates Cer!ficate Authority Cer!ficate Revoca!on List CHAP DES DHCP DNS DUN Encryp!on Ethernet Firewall Gateway Hub Internet Intranet Ethernet Bonding or Failover is the ability to detect communica!on failure transparently, and switch from one LAN connec!on to another. Bootstrap Protocol. A protocol that allows a network user to automa!cally receive an IP address and have an opera!ng system boot without user interac!on. BOOTP is the basis for the more advanced DHCP. A digitally signed statement that contains informa!on about an en!ty and the en!ty's public key, thus binding these two pieces of informa!on together. A cer!ficate is issued by a trusted organiza!on (or en!ty) called a Cer!fica!on Authority (CA) a&er the CA has verified that the en!ty is who it says it is. A Cer!ficate Authority is a trusted third party, which cer!fies public key's to truly belong to their claimed owners. It is a key part of any Public Key Infrastructure, since it allows users to trust that a given public key is the one they wish to use, either to send a private message to its owner or to verify the signature on a message sent by that owner. A list of cer!ficates that have been revoked by the CA before they expired. This may be necessary if the private key cer!ficate has been compromised or if the holder of the cer!ficate is to be denied the ability to establish a connec!on to the console server. Challenge-Handshake Authen!ca!on Protocol (CHAP) is used to verify a user's name and password for PPP Internet connec!ons. It is more secure than PAP, the other main authen!ca!on protocol. The Data Encryp!on Standard is a block cipher with 64-bit blocks and a 56-bit key. Dynamic Host Configura!on Protocol. A communica!ons protocol that assigns IP addresses to computers when they are connected to the network. The Domain Name System allocates Internet domain names and translates them into IP addresses. A domain name is a meaningful and easy to remember name for an IP address. Dial-up Networking. The technique for conver!ng a readable message (plaintext) into apparently random material (ciphertext) which cannot be read if intercepted. The proper decryp!on key is required to read the message. A physical network layer protocol based upon IEEE standards. A network gateway device that protects a private network from users on other networks. A firewall is usually installed to allow users on an intranet access to the public Internet without allowing public Internet users access to the intranet. A machine that provides a route (or pathway) to the outside world. A network device that allows more than one computer to be connected as a LAN, usually using UTP cabling. A worldwide system of computer networks - a public, coopera!ve, and self-sustaining network of networks accessible to hundreds of millions of people worldwide. The Internet is technically dis!nguished because it uses the TCP/IP set of protocols. A private TCP/IP network within an enterprise. Opengear User Manual. Page 361. IP address IPMI Key life!mes LAN LDAP LED MAC address Fundamental internet addressing method that uses the form nnn.nnn.nnn.nnn. Intelligent Pla*orm Management Interface (IPMI) is a set of common interfaces to a computer system which system administrators can use to monitor system health and manage the system. The IPMI standard defines the protocols for interfacing with a service processor embedded into a server pla*orm. The length of !me before keys are re-nego!ated. Local Area Network. The Lightweight Directory Access Protocol (LDAP) is based on the X.500 standard, but significantly simpler and more readily adapted to meet custom needs. The core LDAP specifica!ons are all defined in RFCs. LDAP is a protocol used to access informa!on stored in an LDAP server. Light-Emi$ng Diode. Every piece of Ethernet hardware has a unique number assigned to it called its MAC address. Ethernet is used locally to connect the console server to the Internet, and it may share the local network with many other appliances. The MAC address is used by the local Internet router in order to direct console server traffic to it rather than something else in the local area. It is a 48-bit number usually wri%en as a series of 6 hexadecimal octets. For example: 00:d0:cf:00:5b:da. A console server has a MAC address listed on a label underneath the device. MSCHAP Microso& Challenge Handshake Authen!ca!on Protocol (MSCHAP) is authen!ca!on for PPP connec!ons between a computer using a Microso& Windows opera!ng system and a network access server. It is more secure than PAP or CHAP, and is the only op!on that also supports data encryp!on. NAT Network Address Transla!on. The transla!on of an IP address used on one network to an IP address on another network. Masquerading is one par!cular form of NAT. Net mask The way that computers know which part of a TCP/IP address refers to the network, and which part refers to the host range. NFS Network File System is a protocol that allows file sharing across a network. Users can view, store, and update files on a remote computer. Out-of-band (OOB) Out-of-Band (OOB) management is any management done over channels and interfaces that are separate from those used for user/ customer data. Examples would include a serial console interface or a network interface connected to a dedicated management network that is not used to carry customer traffic, or to a BMC/service processor. Any management done over the same channels and interfaces used for user/ customer data is In Band. PAP Password Authen!ca!on Protocol (PAP) is the usual method of user authen!ca!on used on the internet: sending a username and password to a server where they are compared with a table of authorized users. Whilst most common, PAP is the least secure of the authen!ca!on op!ons. Opengear User Manual. Page 362. PPP RADIUS Router SIM SMASH SMTP SOL SSH SSL TACACS+ TCP/IP Telnet Point-to-Point Protocol. A networking protocol for establishing simple links between two peers. The Remote Authen!ca!on Dial-In User Service (RADIUS) protocol was developed by Livingston Enterprises as an access server authen!ca!on and accoun!ng protocol. The RADIUS server can support a variety of methods to authen!cate a user. When it is provided with the username and original password given by the user, it can support PPP, PAP or CHAP, UNIX login, and other authen!ca!on mechanisms. A network device that moves packets of data. A router differs from a hub or a switch because it is intelligent and can route packets to their final des!na!on. Subscriber Iden!ty Module (SIM) card stores unique serial numbers and security authen!ca!on used to iden!fy a subscriber on mobile telephony devices. Systems Management Architecture for Server Hardware is a standardsbased protocols aimed at increasing produc!vity of the management of a data center. The SMASH Command Line Protocol (SMASH CLP) specifica!on provides an intui!ve interface to heterogeneous servers independent of machine state, opera!ng system or OS state, system topology or access method. It is a standard method for local and remote management of server hardware using out-of-band communica!on. Simple Mail Transfer Protocol. console server includes, SMTPclient, a minimal SMTP client that takes an email message body and passes it on to a SMTP server (default is the MTA on the local host). Serial Over LAN (SOL) enables servers to transparently redirect the serial character stream from the baseboard universal asynchronous receiver/transmi%er (UART) to and from the remote-client system over a LAN. With SOL support and BIOS redirec!on (to serial) remote managers can view the BIOS/POST output during power on, and reconfigured. Secure Shell is secure transport protocol based on public-key cryptography. Secure Sockets Layer is a protocol that provides authen!ca!on and encryp!on services between a web server and a web browser. The Terminal Access Controller Access Control System (TACACS+) security protocol is a more recent protocol developed by Cisco. It provides detailed accoun!ng informa!on and flexible administra!ve control over the authen!ca!on and authoriza!on processes. TACACS+ allows for a single access control server (the TACACS+ daemon) to provide authen!ca!on, authoriza!on, and accoun!ng services independently. Each service can be !ed into its own database to take advantage of other services available on that server or on the network, depending on the capabili!es of the daemon. There is a dra& RFC detailing this protocol. Transmission Control Protocol/Internet Protocol. The basic protocol for Internet communica!on. Telnet is a terminal protocol that provides an easy-to-use method of crea!ng terminal connec!ons to a network. Opengear User Manual. Page 363. UDP UTC UTP VNC VPN WAN WINS User Datagram Protocol. Co-ordinated Universal Time (equivalent to and replacement for GMT or Greenwich Mean Time). Unshielded Twisted Pair cabling. A type of Ethernet cable that can operate up to 100Mb/s. Also known as Category 5 or CAT 5. Virtual Network Compu!ng (VNC) is a desktop protocol to remotely control another computer. It transmits the keyboard presses and mouse clicks from one computer to another relaying the screen updates back in the other direc!on, over a network. Virtual Private Network (VPN) a network that uses a public telecommunica!on infrastructure and Internet, to provide remote offices or individual users with secure access to their organiza!on's network. Wide Area Network. Windows Internet Naming Service (WINS) that manages the associa!on of worksta!on names and loca!ons with IP addresses. Opengear User Manual. Page 364. Appendix 6. End-user license agreements Appendix 6.1.Opengear end-user license agreement READ BEFORE USING THE ACCOMPANYING SOFTWARE YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE USING THE ACCOMPANYING SOFTWARE, THE USE OF WHICH IS LICENSED FOR USE ONLY AS SET FORTH BELOW. IF YOU DO NOT AGREE TO THE TERMS AND CONDITIONS OF THIS AGREEMENT, DO NOT USE THE SOFTWARE. IF YOU USE ANY PART OF THE SOFTWARE, SUCH USE WILL INDICATE THAT YOU ACCEPT THESE TERMS. You have acquired a product that includes Opengear ("Opengear") proprietary so&ware and/ or proprietary so&ware licensed to Opengear. This Opengear End User License Agreement ("EULA") is a legal agreement between you (either an individual or a single en!ty) and Opengear for the installed so&ware product of Opengear origin, as well as associated media, printed materials, and "online" or electronic documenta!on ("So&ware"). By installing, copying, downloading, accessing, or otherwise using the So&ware, you agree to be bound by the terms of this EULA. If you do not agree to the terms of this EULA, Opengear is not willing to license the So&ware to you. In such event, do not use or install the So&ware. If you have purchased the So&ware, promptly return the So&ware and all accompanying materials with proof of purchase for a refund. Products with separate end user license agreements that may be provided along with the So&ware are licensed to you under the terms of those separate end user license agreements. LICENSE GRANT. Subject to the terms and condi!ons of this EULA, Opengear grants you a nonexclusive right and license to install and use the So&ware on a single CPU, provided that, Opengear User Manual. Page 365. (1) you may not rent, lease, sell, sublicense or lend the So&ware; (2) you may not reverse engineer, decompile, disassemble or modify the So&ware, except and only to the extent that such ac!vity is expressly permi%ed by applicable law notwithstanding this limita!on; and (3) you may not transfer rights under this EULA unless such transfer is part of a permanent sale or transfer of the Product, you transfer at the same !me all copies of the So&ware to the same party or destroy such materials not transferred, and the recipient agrees to this EULA. No license is granted in any of the So&ware's proprietary source code. This license does not grant you any rights to patents, copyright, trade secrets, trademarks or any other rights with respect to the So&ware. You may make a reasonable number of copies of the electronic documenta!on accompanying the So&ware for each So&ware license you acquire, provided that, you must reproduce and include all copyright no!ces and any other proprietary rights no!ces appearing on the electronic documenta!on. Opengear reserves all rights not expressly granted herein. INTELLECTUAL PROPERTY RIGHTS. The So&ware is protected by copyright laws, interna!onal copyright trea!es, and other intellectual property laws and trea!es. Opengear and its suppliers retain all ownership of, and intellectual property rights in (including copyright), the So&ware components and all copies thereof, provided however, that (1) certain components of the So&ware, including SDT Connector, are components licensed under the GNU General Public License Version 2, which Opengear supports, and (2) the SDT Connector includes code from JSch, a pure Java implementa!on of SSH2 which is licensed under BSD style license. Copies of these licenses are detailed below and Opengear will provide source code for any of the components of the So&ware licensed under the GNU General Public License upon request. EXPORT RESTRICTIONS. You agree that you will not export or re-export the So&ware, any part thereof, or any process or service that is the direct product of the So&ware in viola!on of any applicable laws or regula!ons of the United States or the country in which you obtained them. U.S. GOVERNMENT RESTRICTED RIGHTS. The So&ware and related documenta!on are provided with Restricted Rights. Use, duplica!on, or disclosure by the Government is subject to restric!ons set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer So&ware clause at DFARS 252.227-7013 or subparagraphs (c) (1) and (2) of the Commercial Computer So&ware Restricted Rights at 48 C.F.R. 52.227-19, as applicable, or any successor regula!ons. TERM AND TERMINATION. This EULA is effec!ve un!l terminated. The EULA terminates immediately if you fail to comply with any term or condi!on. In such an event, you must destroy all copies of the So&ware. You may also terminate this EULA at any !me by destroying the So&ware. GOVERNING LAW AND ATTORNEY'S FEES. This EULA is governed by the laws of the State of Utah, USA, excluding its conflict of law rules. You agree that the United Na!ons Conven!on on Contracts for the Interna!onal Sale of Goods is hereby excluded in its en!rety and does not apply to this EULA. If you acquired this So&ware in a country outside of the United States, that country's laws may apply. In any ac!on or suit to enforce any right or remedy under this EULA or to interpret any provision of this EULA, the prevailing party will be en!tled to recover its costs, including reasonable a%orneys' fees. ENTIRE AGREEMENT. This EULA cons!tutes the en!re agreement between you and Opengear with respect to the So&ware, and supersedes all other agreements or Opengear User Manual. Page 366. representa!ons, whether wri%en or oral. The terms of this EULA can only be modified by express wri%en consent of both par!es. If any part of this EULA is held to be unenforceable as wri%en, it will be enforced to the maximum extent allowed by applicable law, and will not affect the enforceability of any other part. Should you have any ques!ons concerning this EULA, or if you desire to contact Opengear for any reason, please contact the Opengear representa!ve serving your company. THE FOLLOWING DISCLAIMER OF WARRANTY AND LIMITATION OF LIABILITY IS INCORPORATED INTO THIS EULA BY REFERENCE. THE SOFTWARE IS NOT FAULT TOLERANT. YOU HAVE INDEPENDENTLY DETERMINED HOW TO USE THE SOFTWARE IN THE DEVICE, AND OPENGEAR HAS RELIED UPON YOU TO CONDUCT SUFFICIENT TESTING TO DETERMINE THAT THE SOFTWARE IS SUITABLE FOR SUCH USE. LIMITED WARRANTY Opengear warrants the media containing the So&ware for a period of ninety (90) days from the date of original purchase from Opengear or its authorized retailer. Proof of date of purchase will be required. Any updates to the So&ware provided by Opengear (which may be provided by Opengear at its sole discre!on) shall be governed by the terms of this EULA. In the event the product fails to perform as warranted, Opengear's sole obliga!on shall be, at Opengear's discre!on, to refund the purchase price paid by you for the So&ware on the defec!ve media, or to replace the So&ware on new media. Opengear makes no warranty or representa!on that its So&ware will meet your requirements, will work in combina!on with any hardware or applica!on so&ware products provided by third par!es, that the opera!on of the so&ware products will be uninterrupted or error free, or that all defects in the So&ware will be corrected. OPENGEAR DISCLAIMS ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. OTHER THAN AS STATED HEREIN, THE ENTIRE RISK AS TO SATISFACTORY QUALITY, PERFORMANCE, ACCURACY, AND EFFORT IS WITH YOU. ALSO, THERE IS NO WARRANTY AGAINST INTERFERENCE WITH YOUR ENJOYMENT OF THE SOFTWARE OR AGAINST INFRINGEMENT. IF YOU HAVE RECEIVED ANY WARRANTIES REGARDING THE DEVICE OR THE SOFTWARE, THOSE WARRANTIES DO NOT ORIGINATE FROM, AND ARE NOT BINDING ON, OPENGEAR. NO LIABILITY FOR CERTAIN DAMAGES. EXCEPT AS PROHIBITED BY LAW, OPENGEAR SHALL HAVE NO LIABILITY FOR COSTS, LOSS, DAMAGES OR LOST OPPORTUNITY OF ANY TYPE WHATSOEVER, INCLUDING BUT NOT LIMITED TO, LOST OR ANTICIPATED PROFITS, LOSS OF USE, LOSS OF DATA, OR ANY INCIDENTAL, EXEMPLARY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER UNDER CONTRACT, TORT, WARRANTY OR OTHERWISE ARISING FROM OR IN CONNECTION WITH THIS EULA OR THE USE OR PERFORMANCE OF THE SOFTWARE. IN NO EVENT SHALL OPENGEAR BE LIABLE FOR ANY AMOUNT IN EXCESS OF THE LICENSE FEE PAID TO OPENGEAR UNDER THIS EULA. SOME STATES AND COUNTRIES DO NOT ALLOW THE LIMITATION OR EXCLUSION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THIS LIMITATION MAY NOT APPLY TO YOU. Appendix 6.2.JSch license SDT Connector includes code from JSch, a pure Java implementa!on of SSH2. JSch is licensed under BSD style license and it is: Opengear User Manual. Page 367. Copyright © 2002, 2003, 2004 Atsuhiko Yamanaka, JCra&, Inc. All rights reserved. Redistribu!on and use in source and binary forms, with or without modifica!on, are permi%ed provided that the following condi!ons are met: 1. Redistribu!ons of source code must retain the above copyright no!ce, this list of condi!ons and the following disclaimer. 2. Redistribu!ons in binary form must reproduce the above copyright no!ce, this list of condi!ons and the following disclaimer in the documenta!on and/or other materials provided with the distribu!on. 3. The names of the authors may not be used to endorse or promote products derived from this so&ware without specific prior wri%en permission. THIS SOFTWARE IS PROVIDED `AS IS' AND ANY EXPRESSED OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL JCRAFT, INC. OR ANY CONTRIBUTORS TO THIS SOFTWARE BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Appendix 6.3.GNU general public license (GPL), version 2 GNU GENERAL PUBLIC LICENSE Version 2, June 1991 Copyright © 1989, 1991 Free So&ware Founda!on, Inc. 51 Franklin Street, Fi&h Floor, Boston, MA 02110-1301, USA Everyone is permi%ed to copy and distribute verba!m copies of this license document, but changing it is not allowed. GNU GENERAL PUBLIC LICENSE TERMS AND CONDITIONS FOR COPYING, DISTRIBUTION AND MODIFICATION 0. This License applies to any program or other work which contains a no!ce placed by the copyright holder saying it may be distributed under the terms of this General Public License. The "Program", below, refers to any such program or work, and a "work based on the Program" means either the Program or any deriva!ve work under copyright law: that is to say, a work containing the Program or a por!on of it, either verba!m or with modifica!ons and/or translated into another language. (Hereina&er, transla!on is included without limita!on in the term "modifica!on".) Each licensee is addressed as "you". Ac!vi!es other than copying, distribu!on and modifica!on are not covered by this License; they are outside its scope. The act of running the Program is not restricted, and the output from the Program is covered only if its contents cons!tute a work based on the Program (independent of having been made by running the Program). Whether that is true depends on what the Program does. Opengear User Manual. Page 368. 1. You may copy and distribute verba!m copies of the Program's source code as you receive it, in any medium, provided that you conspicuously and appropriately publish on each copy an appropriate copyright no!ce and disclaimer of warranty; keep intact all the no!ces that refer to this License and to the absence of any warranty; and give any other recipients of the Program a copy of this License along with the Program. You may charge a fee for the physical act of transferring a copy, and you may at your op!on offer warranty protec!on in exchange for a fee. 2. You may modify your copy or copies of the Program or any por!on of it, thus forming a work based on the Program, and copy and distribute such modifica!ons or work under the terms of Sec!on 1 above, provided that you also meet all of these condi!ons: a) You must cause the modified files to carry prominent notices stating that you changed the files and the date of any change. b) You must cause any work that you distribute or publish, that in whole or in part contains or is derived from the Program or any part thereof, to be licensed as a whole at no charge to all third parties under the terms of this License. c) If the modified program normally reads commands interactively when run, you must cause it, when started running for such interactive use in the most ordinary way, to print or display an announcement including an appropriate copyright notice and a notice that there is no warranty (or else, saying that you provide a warranty) and that users may redistribute the program under these conditions, and telling the user how to view a copy of this License. (Exception: if the Program itself is interactive but does not normally print such an announcement, your work based on the Program is not required to print an announcement.) 3. You may copy and distribute the Program (or a work based on it, under Sec!on 2) in object code or executable form under the terms of Sec!ons 1 and 2 above provided that you also do one of the following: a) Accompany it with the complete corresponding machine-readable source code, which must be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange; or, b) Accompany it with a written offer, valid for at least three years, to give any third party, for a charge no more than your cost of physically performing source distribution, a complete machine-readable copy of the corresponding source code, to be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange; or, c) Accompany it with the information you received as to the offer to distribute corresponding source code. (This alternative is allowed only for noncommercial distribution and only if you received the program in object code or executable form with such an offer, in accord with Subsection b above.) The source code for a work means the preferred form of the work for making modifica!ons to it. For an executable work, complete source code means all the source code for all modules it contains, plus any associated interface defini!on files, plus the scripts used to control compila!on and installa!on of the executable. However, as a special excep!on, the source code distributed need not include anything that is normally distributed (in either source or binary form) with the major components (compiler, kernel, and so on) of the opera!ng system on which the executable runs, unless that component itself accompanies the executable. If distribu!on of executable or object code is made by offering access to copy from a Opengear User Manual. Page 369. designated place, then offering equivalent access to copy the source code from the same place counts as distribu!on of the source code, even though third par!es are not compelled to copy the source along with the object code. 4. You may not copy, modify, sublicense, or distribute the Program except as expressly provided under this License. Any a%empt otherwise to copy, modify, sublicense or distribute the Program is void, and will automa!cally terminate your rights under this License. However, par!es who have received copies, or rights, from you under this License will not have their licenses terminated so long as such par!es remain in full compliance. 5. You are not required to accept this License, since you have not signed it. However, nothing else grants you permission to modify or distribute the Program or its deriva!ve works. These ac!ons are prohibited by law if you do not accept this License. Therefore, by modifying or distribu!ng the Program (or any work based on the Program), you indicate your acceptance of this License to do so, and all its terms and condi!ons for copying, distribu!ng or modifying the Program or works based on it. 6. Each !me you redistribute the Program (or any work based on the Program), the recipient automa!cally receives a license from the original licensor to copy, distribute or modify the Program subject to these terms and condi!ons. You may not impose any further restric!ons on the recipients' exercise of the rights granted herein. You are not responsible for enforcing compliance by third par!es to this License. 7. If, as a consequence of a court judgment or allega!on of patent infringement or for any other reason (not limited to patent issues), condi!ons are imposed on you (whether by court order, agreement or otherwise) that contradict the condi!ons of this License, they do not excuse you from the condi!ons of this License. If you cannot distribute so as to sa!sfy simultaneously your obliga!ons under this License and any other per!nent obliga!ons, then as a consequence you may not distribute the Program at all. For example, if a patent license would not permit royalty-free redistribu!on of the Program by all those who receive copies directly or indirectly through you, then the only way you could sa!sfy both it and this License would be to refrain en!rely from distribu!on of the Program. If any por!on of this sec!on is held invalid or unenforceable under any par!cular circumstance, the balance of the sec!on is intended to apply and the sec!on as a whole is intended to apply in other circumstances. It is not the purpose of this sec!on to induce you to infringe any patents or other property right claims or to contest validity of any such claims; this sec!on has the sole purpose of protec!ng the integrity of the free so&ware distribu!on system, which is implemented by public license prac!ces. Many people have made generous contribu!ons to the wide range of so&ware distributed through that system in reliance on consistent applica!on of that system; it is up to the author/donor to decide if he or she is willing to distribute so&ware through any other system and a licensee cannot impose that choice. This sec!on is intended to make thoroughly clear what is believed to be a consequence of the rest of this License. 8. If the distribu!on and/or use of the Program is restricted in certain countries either by patents or by copyrighted interfaces, the original copyright holder who places the Program under this License may add an explicit geographical distribu!on limita!on excluding those countries, so that distribu!on is permi%ed only in or among countries not thus excluded. In such case, this License incorporates the limita!on as if wri%en in the body of this License. Opengear User Manual. Page 370. 9. The Free So&ware Founda!on may publish revised and/or new versions of the General Public License from !me to !me. Such new versions will be similar in spirit to the present version, but may differ in detail to address new problems or concerns. Each version is given a dis!nguishing version number. If the Program specifies a version number of this License which applies to it and "any later version", you have the op!on of following the terms and condi!ons either of that version or of any later version published by the Free So&ware Founda!on. If the Program does not specify a version number of this License, you may choose any version ever published by the Free So&ware Founda!on. 10.If you wish to incorporate parts of the Program into other free programs whose distribu!on condi!ons are different, write to the author to ask for permission. For so&ware which is copyrighted by the Free So&ware Founda!on, write to the Free So&ware Founda!on; we some!mes make excep!ons for this. Our decision will be guided by the two goals of preserving the free status of all deriva!ves of our free so&ware and of promo!ng the sharing and reuse of so&ware generally. NO WARRANTY 11.BECAUSE THE PROGRAM IS LICENSED FREE OF CHARGE, THERE IS NO WARRANTY FOR THE PROGRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW. EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND/OR OTHER PARTIES PROVIDE THE PROGRAM "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE PROGRAM IS WITH YOU. SHOULD THE PROGRAM PROVE DEFECTIVE, YOU ASSUME THE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION. 12.IN NO EVENT UNLESS REQUIRED BY APPLICABLE LAW OR AGREED TO IN WRITING WILL ANY COPYRIGHT HOLDER, OR ANY OTHER PARTY WHO MAY MODIFY AND/OR REDISTRIBUTE THE PROGRAM AS PERMITTED ABOVE, BE LIABLE TO YOU FOR DAMAGES, INCLUDING ANY GENERAL, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PROGRAM (INCLUDING BUT NOT LIMITED TO LOSS OF DATA OR DATA BEING RENDERED INACCURATE OR LOSSES SUSTAINED BY YOU OR THIRD PARTIES OR A FAILURE OF THE PROGRAM TO OPERATE WITH ANY OTHER PROGRAMS), EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. END OF TERMS AND CONDITIONS Appendix 6.4.Wireless driver license The Opengear firmware includes 802.11 driver code which is used in various console server models. This code is: Copyright © 2007, Ralink Technology Corpora!on All rights reserved. Redistribu!on and use in binary form, without modifica!on, are permi%ed provided that the following condi!ons are met: · Redistribu!ons must reproduce the above copyright no!ce and the following disclaimer in the documenta!on and/or other materials provided with the distribu!on Opengear User Manual. Page 371. · Neither the name of Ralink Technology Corpora!on nor the names of its suppliers may be used to endorse or promote products derived from this so&ware without specific prior wri%en permission · No reverse engineering, decompila!on, or disassembly of this so&ware is permi%ed Ralink Technology Corpora!on grants a world-wide, royalty-free, non-exclusive license under patents it now or herea&er owns or controls to make, have made, use, import, offer to sell and sell ("U!lize") this so&ware, but solely to the extent that any such patent is necessary to U!lize the so&ware alone, or in combina!on with an opera!ng system licensed under an approved Open Source license as listed by the Open Source Ini!a!ve at h%p:// opensource.org/licenses. The patent license shall not apply to any other combina!ons which include this so&ware. No hardware per se is licensed hereunder. DISCLAIMER. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH Opengear User Manual. Page 372. Appendix 7. Service & standard warranty Appendix 7.1.Standard warranty Opengear, Inc., its parent, affiliates and subsidiaries, (collec!vely, "Opengear") warrant your Opengear product to be in good working order and to be free from defects in workmanship and material (except in those cases where the materials are supplied by the Purchaser) under normal and proper use and service for the period of four (4) years from the date of original purchase from an Authorized Opengear reseller. In the event that this product fails to meet this warranty within the applicable warranty period, and provided that Opengear confirms the specified defects, Purchaser's sole remedy is to have Opengear, in Opengear's sole discre!on, repair or replace such product at the place of manufacture, at no addi!onal charge other than the cost of freight of the defec!ve product to and from the Purchaser. Repair parts and replacement products will be provided on an exchange basis and will be either new or recondi!oned. Opengear will retain, as its property, all replaced parts and products. Notwithstanding the foregoing, this hardware warranty does not include service to replace or repair damage to the product resul!ng from accident, disaster, abuse, misuse, electrical stress, negligence, any non- Opengear modifica!on of the product except as provided or explicitly recommended by Opengear, or other cause not arising out of defects in material or workmanship. This hardware warranty also does not include service to replace or repair damage to the product if the serial number or seal or any part thereof has been altered, defaced or removed. If Opengear does not find the product to be defec!ve, the Purchaser will be invoiced for said inspec!on and tes!ng at Opengear's then current rates, regardless of whether the product is under warranty. Appendix 7.2.RMA return procedure Opengear User Manual. Page 373. If this product requires service during the applicable warranty period, a Return Materials Authoriza!on (RMA) number must first be obtained from Opengear. Product that is returned to Opengear for service or repair without an RMA number will be returned to the sender unexamined. Return product, freight prepaid, in its original or equivalent packaging, to: Opengear Service Center Suite A, 630 West 9560 South Sandy, Utah 84070 Proof of purchase date must accompany the returned product and the Purchaser shall agree to insure the product or assume the risk of loss of damage in transit. Contact Opengear by emailing support@opengear.com for further informa!on. Appendix 7.3.Technical support Purchaser is en!tled to thirty (30) days free telephone support and twelve (12) months free email support (worldwide) from date of purchase provided that the Purchaser first register their product(s) with Opengear by filling in the on-line form h%p://opengear.com/registra!on.html. Direct telephone, help-desk and e-mail support is available from 09:00 to 20:00, US Eastern Time (UTC -5 or UTC -4). Other support op!ons are at h%p://opengear.com/support.html. Opengear's standard warranty includes free access to Opengear's Knowledge Base as well as any applica!on notes, white papers and other on-line resources that may become available from !me to !me. Opengear reserves the right to stop support for products no longer covered by warranty. Appendix 7.4.Limita"on of Liability No ac!on, regardless of form, arising from this warranty may be brought by either party more than two (2) years a&er the cause of ac!on has occurred. Purchaser expressly agrees that Opengear's liability, if any, shall be limited solely to the replacement or repair of the product in accordance with the warran!es specifically and expressly set forth herein. The remedies of the Purchaser are the exclusive and sole remedies available, and, in the event of a breach or repudia!on of any provision of this agreement by Opengear, the Purchaser shall not be en!tled to receive any incidental damages as that term is defined in Sec!on 2-715 of the Uniform Commercial Code. Opengear waives the benefit of any rule that disclaimer of warranty shall be construed against Opengear and agrees that such disclaimers herein shall be construed liberally in favor of Opengear. THE FOREGOING WARRANTIES ARE THE SOLE AND EXCLUSIVE WARRANTIES GIVEN IN CONNECTION WITH THE PRODUCT AND THE HARDWARE. OPENGEAR DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES AS TO THE SUITABILITY OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY RIGHTS. OPENGEAR DOES NOT PROMISE THAT THE PRODUCT IS ERROR-FREE OR WILL OPERATE WITHOUT INTERRUPTION. IN NO EVENT SHALL OPENGEAR BE LIABLE FOR ANY LOST OR ANTICIPATED PROFITS, OR ANY INCIDENTAL, EXEMPLARY, SPECIAL OR CONSEQUENTIAL DAMAGES, REGARDLESS OF WHETHER OPENGEAR WAS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Opengear User Manual. Page 374.Mac OS X 10.11.6 Quartz PDFContext