CERTIFICATE OF CALIBRATION ISSUED BY UL INTERNATIONAL (UK) LTD DATE OF ISSUE: 06/Oct/2021 CERTIFICATE NUMBER : 13697410JD01H 5772 UL INTERNATIONAL (UK) LTD UNIT 1-3 HORIZON KINGSLAND PARK, WADE ROAD BASINGSTOKE, HAMPSHIRE RG24 8AH, UK TEL: +44 (0) 1256 312100 FAX: +44 (0) 1256 312001 Email: LST.UK.Calibration@ul.com Page 1 of 10 APPROVED SIGNATORY .................................... Naseer Mirza Customer : UL VS Inc 47173 Benicia Street Fremont, CA 94538, USA Equipment Details: Description: Manufacturer: Type/Model Number: Serial Number: Calibration Date: Calibrated By: Signature: Dipole Validation Kit Speag D2600V2 1006 29/Sep/2021 Masood Khan Test Engineer Date of Receipt: .................................... 24/Sep/2021 All Calibration have been conducted in the closed laboratory facility: Lab Temperature (22±3) 0C and humidity < 70% This certificate is issued in accordance with the laboratory accreditation requirements of the United Kingdom Accreditation Service. It provides traceability of measurement to the SI system of units and/or to units of measurement realised at the National Physical Laboratory or other recognised national metrology institutes. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Use of the UKAS mark demonstrates that compliance with the requirements of BS/EN/ISO/IEC 17025:2017 has been independently assessed. CERTIFICATE OF CALIBRATION ISSUED BY UL INTERNATIONAL (UK) LTD UKAS Accredited Calibration Laboratory No. 5772 CERTIFICATE NUMBER : 13697410JD01H Page 2 of 10 The calibration methods and procedures used were as detailed in: 1. IEC 62209-1:2016: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz) 2. IEC 62209-2:2010: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) 3. IEEE 1528: 2013: IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communication Devices: Measurement Techniques 4. FCC KDB Publication Number: "KDB865664 D01 SAR Measurement 100 MHz to 6 GHz" 5. DASY 6 System Handbook 6. Dipole Calibration Procedure V1.2: Calibration performed as per internal procedure The measuring equipment used to perform the calibration, documented in this certificate has been calibrated in accordance with the manufacturers' recommendations, and is traceable to recognized national standards. UL No. Instrument Manufacturer PRE0135115 PRE0134817 PRE0135603 PRE0151451 PRE0151441 Data Acquisition Electronics Probe Dipole Power Monitoring Kit Power Sensor M2028 Vector Network Analyser M2029 M1647 Calibration Kit Signal Generator SPEAG SPEAG SPEAG Art-Fi Rhode & Schwarz Keysight Technologies Keysight Technologies HP Type No. Serial No. Date Last Calibrated Cal. Interval (Months) DAE4 1438 12 Apr 2021 12 ES3DV3 D2600V2 ART 100850-01 NRP8S 3335 SN1109 0001 102481 14 Jan 2021 12 15 Feb 2021 12 Cal as part of System - 22 Mar 2021 12 E5071C MY46521873 20 Jul 2021 12 N4691B MY46181255 02 Aug 2021 12 8648C 3537A01598 03 Mar 2021 12 CERTIFICATE OF CALIBRATION ISSUED BY UL INTERNATIONAL (UK) LTD UKAS Accredited Calibration Laboratory No. 5772 CERTIFICATE NUMBER : 13697410JD01H Page 3 of 10 SAR System Specification Robot System Positioner: Robot Serial Number: DASY Version: Phantom: Distance Dipole Centre: Frequency: Stäubli Unimation Corp. Robot Model: TX60L F17/5ENYG1/A/01 cDASY16.0.0.116 Flat section of SAM Twin Phantom 10 mm (with spacer) 2600 MHz Dielectric Property Measurements Head Simulating Liquid (HSL) Simulant Liquid Head Frequency (MHz) 2600 Room Temp Start End 21.6 21.2 Liquid Temp Start End 20.8 21.1 Parameters r Target Value 39.00 1.96 Measured Value 39.23 1.94 Uncertainty (%) ± 5% ± 5% SAR Results Head Simulating Liquid (HSL) Simulant Liquid SAR Measured 250 mW input Power Normalised to 1.00 W Head SAR averaged over 1g SAR averaged over 10g 13.80 W/Kg 6.34 W/Kg 54.94 W/Kg 25.24 W/Kg Uncertainty (%) +16.80 / -16.43% +16.72 / -16.42% Antenna Parameters Head Simulating Liquid (HSL) Simulant Liquid Parameter Measured Level Head Impedance Return Loss 44.09 + 0.92j 23.74 Uncertainty (%) ± 3.01 ± 2.93 CERTIFICATE OF CALIBRATION ISSUED BY UL INTERNATIONAL (UK) LTD UKAS Accredited Calibration Laboratory No. 5772 DASY Validation Scan for Head Stimulating Liquid (HSL) DUT: D2600V2; Type: Dipole; Serial: SN1006; CERTIFICATE NUMBER : 13697410JD01H Page 5 of 10 Communication System: CW UID: 0; Frequency: 2600.0 MHz; Duty Cycle: 1; Medium: HSL; Site65_28Sep2021_082639_Head - 900 1800 1900 2300 2600 5%; Medium parameters used: f = 2600.0 MHz; = 1.94 S/m; r = 39.2; = 1000 kg/m3; r = 0.57 %; = -1.03 %; No correction Phantom section: Flat; DASY 6 Configuration: - Laboratory Name: Site65; - Probe: ES3DV3 - SN3335; ConvF(4.44, 4.44, 4.44); Calibrated: 14 Jan 2021 - Sensor-Surface: 3 mm; VMS + 6p - Electronics: DAE4 - SN1438; Calibrated: 12 Apr 2021 - Phantom: Twin-SAM V8.0 (30deg probe tilt); Serial: 1945 - Measurement SW: cDASY16.0.0.116 Area Scan (40x80):Interpolated grid: dx=10 mm, dy=10 mm Zoom Scan1(30x30x30):Measurement grid: dx=5 mm, dy=5 mm, dz=1.5 mm; Grading Ratio: 1.5; Reference Value = 18.620 V/m; Power Drift = 0.00 dB Minimum horizontal 3dB distance: 9.1 mm; Vertical M2/M1 Ratio: 81.0 %; SAR(1 g) = 13.800 W/kg; SAR(10 g) = 6.340 W/kg CERTIFICATE OF CALIBRATION ISSUED BY UL INTERNATIONAL (UK) LTD CERTIFICATE NUMBER : 13697410JD01H UKAS Accredited Calibration Laboratory No. 5772 Page 6 of 10 Impedance Measurement Plot for Head Stimulating Liquid (HSL) CERTIFICATE OF CALIBRATION ISSUED BY UL INTERNATIONAL (UK) LTD CERTIFICATE NUMBER : 13697410JD01H UKAS Accredited Calibration Laboratory No. 5772 Page 7 of 10 Return Loss Measurement Plot for Head Stimulating Liquid (HSL) Calibration Certificate Label: UL INTERNATIONAL (UK) LTD Tel: +44 (0) 1256312000 Certificate Number: 13697410JD01H Instrument ID: 1006 Calibration Date: 29/Sep/2021 5772 Calibration Due Date: UL INTERNATIONAL (UK) LTD Tel: +44 (0) 1256312000 Certificate Number: 13697410JD01H Instrument ID: 1006 Calibration Date: 29/Sep/2021 5772 Calibration Due Date: UL INTERNATIONAL (UK) LTD Tel: +44 (0) 1256312000 Certificate Number: 13697410JD01H Instrument ID: 1006 Calibration Date: 29/Sep/2021 5772 Calibration Due Date:Adobe Acrobat Pro DC (32-bit) 22.1.20169 Adobe Acrobat Pro DC (32-bit) 22.1.20169