司顺工业设计

PDF preview unavailable. Download the PDF instead.

计数秤(sku4-sku10)说明书-20240105(用于生产) 1705022510194
Technical Support and E-Warranty Certificate www.vevor.com/support
Counting Scale USER MANUAL
MODEL: KF-H2C / KF-H2D
We continue to be committed to provide you tools with competitive price. "Save Half", "Half Price" or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and does not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are
actually saving half in comparison with the top major brands.

MODEL: KF-H2C / KF-H2D

COUNTING SCALE

(The picture is for reference only, please refer to the actual object)
NEED HELP? CONTACT US! Have product questions? Need technical support? Please feel free to contact us:
Technical Support and E-Warranty Certificate www.vevor.com/support
This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if there are any technology or software updates on our product.
-1-

A. Main Technical Function.
1. Function:
Auto zero; Counting; ADD; TARE; Backlight
2. Power
AC 220-240V (±10%) 50Hz ± 1 Hz AC 110V (±10%) 60Hz ± 1 Hz DC 6V / 4AH rechargeable battery
3. Power consumption
DC 38 mA DC 58 mAwith backlight
4. Watt0.4Wwith backlight 5. Low power alarm

When it show (

)means need to charge. If keep still using, it's easy to

broken the scale.

B. Technical Data
Capacity 1

capacity

(n)

(e) (d)

(max) (min) zero Tare(max) Overload(max+9e)

15000.0g 15000.0g 0.5g 0.5g 15000.0g 10g ±300g 0~15000.0g

15004.5g

30.000kg 30.000kg 1g 1g 30.000kg 20g ±600g 0~30.000kg

30.009kg

NotesFS= MAX WEIGHT d=division

Additional remark
When the division 1g, generally the unit is KG(e.g. 1g, 2g, 5g ),When the division<1g, generally the unit is G(e.g. 0.1g, 0.2g, 0.5g)

-2-

C. Operation instruction.
1. Before using
(1).Please put the scale on a flat and firm place. It can tighten or loose the four feet to make sure on the same level. there is a level ball on it. (2).Do not use it in hostile environments like strong wind and sunshine. (3).Please use the power supplier alone. (4).Don't put anything on the plate when you turn on. (5).When weighing, please try you best put the good on the center of the plate, don't over it. (6).Turn on the scale after 15-20 Minutes weighing is more better.

(7).Show 

need to charge first.

2. Dispaly:
A: When the unit is KG, the Weight will display 0.000 as picture:

or
-3-

B:When the unit is G, the Weight will display 0.0 as picture:

or (1).WEIGHT
6 digital for the goods weight and add weight and the left digital can display[- ]
(2).UNIT WEIGHT
5 digital for the unit weight and times of add .the point is can change.
(3).QUANTITY
6digital for the pieces of the goods
3. Symbol" "
(1). or Net or Taremeans has been cut the weight of packing (2). or Zeromeans no weight (3).+ or M+means ADD (4). or Stable or ~: Means on stable  (5).SMPLOWmeans sample is not enough. the weight of the sample on the plate is less than the weight of min sample, please add the pieces unit this symbol disappear. (6).QTYPST UWLOWWhen the pcs is low as you set, it will alarm and QTYPST UWLOW .

(7).

Means the power is low, need to charge.

Remark
High precision counting scale: Min sample weight = 20d Min unit weight = 0.2d ( d=division)
counting scaleMin sample weight = 40d Min unit weight= 0.8d ( d=division)

-4-

4. KEYBOARD

OR

(Without RS-232)

(with RS-232)

4.1 Composite key function description

+Number keys0--2convert units

+Numbers keys4--6adjust the brightness

+ set the upper and lower limits of alarmLong

Press to enter the alarm settingPress to closePress to set

the outside of the upper and lower limits of alarmPress to set the inside of

the upper and lower limits of alarmPress to set the upper limits of

alarmPress to confirm

4.2 Function key
: When the unit weight is unknownSet the number of items to be sampled
:When the unit weight is knownConfirm the input weight :Use this key to set the alarm value when a fixed number of alarms are required
-5-

:Disable alarm function
:Add up the quantity of goods :Cancel the total amount of the accumulated items :Remove the weight of tare :Return the scale to zero as far as possible :Clear the number :Print the current weight, single weight, quantity ,and the cumulative data(Note: with the RS232)

5. FUNCTION
5.1. ON-OFF Button

Put ON/OFF to"" means turn on.

Put ON/OFF to "O" Means power off.

5.2. Backlight Auto

Press , when it display "

"press

, I will display"

". Put the

goods on the plateweight >10d, the light is on auto, when it is zero , the light is

off auto.

Light on all the time

Press

when it display"

"press

it will display" ", Light on all

the time .

Light off all the time

press , when it display "

"Press

it will display " ", the light

off all the time.

When you turn off the scale, it will memory what you have choose

-6-

5.3.Kg/g/lb unit choose

Press

when is display"

" then press

, unit is "kg".

Press

when is display"

" then press , unit is "g".

Press

when is display"

" then press , unit is "lb".

5.4.Counting

5.4.1 Before counting, you need to get some samples to know the pcs or unit weight (1) When the unit weight is unknown
Put the samples of relevant goods on the plate (the weight of each sample must be the same): E.g. (A): when the unit is G, put 30pcs screws of each same weight on the plate, It will display:

Weight

Unit weight Total count

[ 53.1g ] [ 0 ]

[0 ]

Input the PCS "30" of the samples(Screws), it will display:

Weight

Unit weight Total count

[53.1g]

[30]

[0]

Then press , it will display:

Weight

Unit weight Total count

[53.1g ]

[1.77g]

[ 30 ]

At this moment you can continue to put the more goods (e.g.: screws) on the plate, the Total weight & Total count will change constantly, the unit weight won't be changed.
E.g. (B): when the unit is KG, put 30pcs screws of each same weight on the plate, It will display:

Weight

Unit weight Total count

[ 0.053kg ] [ 0 ]

[0 ]

-7-

Input the PCS "30" of the samples (Screws), it will display:

Weight

Unit weight Total count

[0.053kg]

[30]

[0]

Then press , it will display:

Weight

Unit weight Total count

[0.053kg ]

[1.766g]

[ 30 ]

At this moment you can continue to put the more goods (e.g. screws) on the plate, the Total weight & Total count will change constantly, the unit weight won't be changed.

(2) Know the unit weight(e.g. screws)

When you know the weight of one screw is 1.766g,

A: if the unit is G, Input the unit weight 1.766,it will display:

[0.0g]

[1.766g] [0]

Then Press , and put the more goods(e.g:30 pcs screws) on the plate,

[53.0g] [1.766g ] [30 ] If at this moment you continue to put the more pcs, the Total weight & Total count on the window will change constantly, the unit weight won't changed. B:If the unit is KG, Input the unit weight 1.766, it will display:

[0.000kg]

[1.766g] [0]

Then Press

, and put the more goods(e.g:30 pcs screws) on the plate,

[0.053kg] [1.766g ] [30 ]

Finally, when you take off all the goods on the plate, the unit window still

displays value, you can press

.

-8-

The sample is more ,the precision is more high

NULL POINT

When you using the scale , sometimes the weight window is not [0.0], you can

press

to make it into [ 0 .0] , Zero range =capacity ×+ 4%

5.4.2 Counting goods have packing

(1).When the packing box /carton weight is unknown (e.g. the unit is KG)

a. Put the packing box of 500g on the plate, it will display

[0.500kg]

[0 ]

[0]

b. Press

, It will display

OR At this moment you can follow 5.4.1 to continue the counting. When the packing box /carton weight is unknown (e.g. the unit is G) a. Put the packing box of 500g on the plate , It will display

[500.0g]

[0 ]

[0]

b. Press , it will display:

[0.0g]

[0 ]

[0]

-9-

Clear the TARE history Take down the goods and package on the plate, the weight will be [- 0.500kg ] on the basis of KG or [- 500.0g ] on the basis of G , Press , The weight will be [0.0], and this  to TARE will disappear.
(2).1-A.When the weight of packing box/carton is known (e.g. the unit is KG) There is nothing on the plate, it display [0.000] [0] [0] The packing box is 500g, Input 500, it will display [0.000] [500] [0] Pres [TARE], it will display [-0.500] [----] [----] Then put that packing box on the plate, it will display 0.000(it means tared),
and at this moment you start to follow the way of 5.4.1 for counting. (3).1-B. When The weight of packing box/carton is known (e.g. the unit is G)
There is nothing on the plate, it display [0.0 g] [0] [0] The packing box is 500g, Input 5000, it will display [0.0g ] [5000] [0] Press , it will display [-500.0g] [----] [----]
Attention: when weight window display "0.0"(it means the unit is G), input the weight of packing box must be 10 times of the actual weight. (e.g:500g package box, you need to input 5000)
At this moment you can firstly put that packing box, it will display "0.0" on the basis of G or "0.000" on the basis of KG, it means both are tared. Then start to follow the step of 5.4.1 to continue the counting. There is some goods including the packing box/carton on the plate.
- 10 -

E.g. Packing box is 500g, on the basis of KG, packing box(500g)+goods(30PCS screws)= 0.553kg , it will display
[ 0.553kg] [0] [0]
Input the weight 1.766 of one screw, press , it will display
[0.553kg] [1.766g] [313]
Input 500( packing box is 500g),press , it will display
[0.053kg] [1.766g] [30] E.g. Packing box is 500g, on the basis of G, packing box(500g)+goods(30PCS screws)= 553.1g , it will display
[ 553.0g] [0] [0]
Input the weight 1.766 of one screw, press , it will display
[553.0g] [1.766g] [313]
Input 5000( actual packing box is 500g), Press the key , it will display
[53.0g] [1.766g] [30] Attention: When weight window display "0.0" (it means the unit is G), input the weight of packing box must be 10 times of the actual weight.(e.g:500g package box, you need to input 5000) Clear the TARE history
Take down the goods and package on the plate, the weight will be [-
0.500kg ], press ,The weight will be [0.0].

5.5. ADD

99Times ADD, 6 Digital

5.5.1 Quantity ADD of repeatedly counting

5.1.1.1 PCS ADD

Put the goods on the plate ,follow as 5.4.1 counting, then press

, Repeat

5.1.1.1, then press

,on the unit weight window will show [2] , it means, 2

- 11 -

times ADD. THE Total COUNT(PCS) will show the two times pcs.(e.g. put 10pcs

screws on the plate, input 10,press SMPL, press

one time, then take off

10pcs screws, put again another 10 pcs screws, press

again. The total count

will display that 20 pcs that they are 1st time's and count of 2nd time's, of course,

the total weight is 1st time +2nd time)

When you finish the counting of all goods, there is no goods on the plate, Press

to check the total weight and times and quantities. Press

and

to

clear the ADD history.

5.5.2 Weight ADD

E.g. the unit is G

Put the goods on the plate like 500g, press

It will display [500.0] [1] [0] for 5 seconds, then to [500.0] [0] [0]

Then take off the goods, put another good s on the plate like 100g, press

It will display [600.0g] [2] [0] for 5 seconds, then to [100.0g] [0] [0].

But when you take off those goods, press

again, you can just check the

total value still is: [600.0g] [2] [0], of course, you can continue to put the

new goods on it, press for counting.

Finally when you finish ADD , there is no goods on the plate, Press

to

check the total weight .Press

to clear the ADD history.

E.g. the basis is KG

Put the goods on the plate Like 500g, press

It will display [0.500kg] [1] [0] for 5 seconds, then to [0.500] [0] [0]

Then take off the goods, put another good s on the plate like 100g, press

It will display [0.600kg] [2] [0] for 5 seconds, then to [0.100g] [0] [0].

- 12 -

But when you take off those goods, press

again, you can just check the

total value still is: [0.600kg] [2] [0], of course, you can continue to put the new

goods on it, press

for counting.

Finally when you finish ADD, there is no goods on the plate, Press

to

check the total weight . Press

to clear the ADD history.

5.6. Quantity alarm

E.g. If over the goods of 30pcs on the plate, you want alarm.

Firstly Input 30 pcs, press

,It will display

[0.000] [0] [30] for 3 second,

then display [0.000] [0] [0]

Put the goods on the plate, when counting(follow the way of 5.4.1 e.g: put 10pcs

goods on the plate, input 10,press

, then continue to put more goods on

it),when the pcs over 30pcs it will alarm.

Press

and

to cancel quantity alarm.

5.7. Calibration

1.Turn on the scale, when the window displays "0", input 52411 and press

key to enter into calibration mode.

2. Press

to choose max capacity, press to confirm, for example:

30kg,input "30000", press to confirm

3.Press

to choose division, press to confirm, for example, when you

press

continuously , it will display"1,2,5,10,", then you choose the division

you need. Then press .

- 13 -

4.Press

to choose position of point, after pressing constantly, it displays

"0""1""2""3""4""0" you can choose the position you need, then press

to confirm."0"means "0", "1"means "0.0" "2"means "0.00", "3"means "0.000" ,

"4"means "0.0000" If you don't need change capacity, division and point, you can

could directly press

to enter next step

5.Weight window will show the data which poise will load on scale(If you what change load poise , you could input the data you will load on scale). press

,the unit price window will display "LOAD" , then put load/weight , finally press

to confirm.

5.8. Upper and Lower Limit Alarms
5.8.1 Selecting Alarm Types

Long-press the

key to enter the settings. The single weight window displays:

Pressing

shows OFF to disable, pressing

shows OUT for out-of-range

alarm, pressing

shows IN for in-range alarm, and pressing

shows UP

for upper limit alarm only. Press

to save and exit.

Short-press the

key to set the quantity upper limit.

5.8.2Inputting Alarm Values (Note: Long-press the

key to activate the alarm,

same as the first step above)

Short-press the

key to enter settings, displaying (A-FF-O-dn). Choose and

input the lower limit value, then input the upper limit value. The weight window displays alarm types: A-OUT indicates out-of-range alarm, A-IN indicates in-range alarm, A-UP indicates upper limit alarm only.

- 14 -

A. When the quantity window displays DN, input the lower limit value, press to confirm and proceed to the next step. B. When the single weight window displays UP, input the upper limit value, press
to confirm and exit.

5.8.3Press

To deactivate the alarm and reset the upper and lower limit

values.
5.9.Printing Function (Note: with the RS232)

5.9.1Single Print

When the weight is not zero, press the weight, and quantity. 5.9.2Add Print

key to print the current weight, single

When multiple weights are accumulated, press the

key to directly print

the accumulated information. After finishing, the cumulative data is automatically cleared.
6.RS232 Connection Computer(Note: with the RS232)
Through the RS232 line to connect the electronic scale with the computer

successfully,press the

key to send the current weight, single weight, and

quantity.

7. Attention:
1. Keep away from the rain and washing by waterif is happen, please dry it, and find it can not work, return to the seller to repair).
2. Please do not store in the high temperature and wet place. 3. Do not let insect into the body. 4. Do not heavy shock and overload. 5. No need using for long time. please clear it, and take it into the bag, and
charge it each 3 months. Recharge it before using .

- 15 -

6. If you have good advise please feel free to tell us.

8.Common trouble shooting:

No TROUBLE

MEANS

REASON

Turn

LOW

1

on ,show"LB " and alarm

BATTERY(POWER)

Turn 2 on ,show"ED WEIGHING ERROR
"

Battery no power
Battery broken
LOAD CELL LINE SEALING -OFF
LOAD CELL TOUCH WITH SOMETHING
LOAD CELL BROKEN

PCB BROKEN

too WET

TOO DURTY

3

Turn on ,hop counting

The weight window number on changing
cannot weighing

LOAD CELL TOUCH WITH SOMETHING LOAD CELL LINE
SEALING -OFF

LOAD CELL BROKEN

When

The weight window

4 charging ,co number on changing

unting

cannot charging

PCB BROKEN Adaptor

Digital 8 not

5

full show

Digital 8 not full show ,or less

electronic circuit short LCD Broken

Drive broken

the key be stucked

the key can not spring

back

key can not press the key can not

6

working

working

key electronic circuit short

PCB BROKEN

KEY BOARD

CORRODE

7 NO WEIGHT

no any weight

the load cell line and PCB link broken

ADVISE RECHARGING
change the battery
RE-SEALING
CHECKING
CHANGE THE LOAD CELL
CHANGE THE PCB DRY the PCB and load
cell take down the PCB, using Alcohol cleaning
first ,then dry it
CHECKING
RE-SEALING
CHANGE THE LOAD CELL
CHANGE THE PCB
change the adaptor
using rubber-insulated wire link together change the LED
change the display board checking
changing the key
using rubber-insulated wire link together
CHANGE THE PCB CHANGE THE KEY
BOARD
checking

- 16 -

can not turn

press the on/off

8

on

button ,can not turn on

when turn on

DI DI DI

when turn on DI DI DI

9 sound all the

sound all the time

time

turn on the sound
10 normal,but no words
turn on 11 show"8"all
the time

turn on the sound normal,but no words
when turn on the scale,all the window
show 8,can not weighing,and the sound it is normal When charging AC light is working,but can not charge

can not

12

recharge

When charging AC light is not working,

no backlight 13 for the LCD

Turn on ,there is no light for the LCD

LOAD CELL LINE SEALING -OFF
LOAD CELL BROKEN PCB BROKEN
the ON/OFF BUTTON BROKEN
CHECK THE BATTERY POWER IS ENOUGH
PCB BROKEN CHECK THE BATTERY POWER IS ENOUGH
PCB BROKEN check the displaybord to
PCB link is ok display board broken check the displaybord to
PCB link is ok
display board broken
Adaptor Battery broken
adaptor adaptor plug charging connect broken the charging connect to the PCB link off PCB BROKEN Battery broken power save function check the LCD part if have sealing-off LCD Broken

RE-SEALING
CHANGE THE LOAD CELL
CHANGE THE PCB CHANGE THE ON/OFF
BUTTON LOW
VOLT ,RECHARGE
BATTERY BROKEN CHANGE IT ,V<5.25V
CHANGE THE PCB LOW
VOLT ,RECHARGE BATTERY BROKEN CHANGE IT ,V<5.25V CHANGE THE PCB
turn off , relink the display board link
change the display board
turn off , relink the display board link
change the display board
change the adaptor
change the battery
change the adaptor take down recharging change the connect part
re sealing
CHANGE THE PCB change the battery reset the backlight on
function
RE-SEALING
CHANGE THE LCD

- 17 -

Items

Description

1 Sales territory North America

2 Name

Counting Scale

3 Model

KF-H2D

4 Parameter

Rating(s): AC110V/60HzCapacity: 30kgDivision: 1gRS232

Items

Description

1 Sales territory North America

2 Name

Counting Scale

3 Model

KF-H2C

4 Parameter

Rating(s): AC110V/60HzCapacity: 30kgDivision: 1gRS232

Items

Description

1 Sales territory Europe

2 Name

Counting Scale

3 Model

KF-H2C

4 Parameter

Rating(s): AC220-240V/50HzCapacity: 30kgDivision: 1g RS232

Items

Description

1 Sales territory Australia

2 Name

Counting Scale

3 Model

KF-H2C

4 Parameter

Rating(s): AC220-240V/50HzCapacity: 30kgDivision: 1g RS232

- 18 -

Items

Description

1 Sales territory North America

2 Name

Counting Scale

3 Model

KF-H2C

4 Parameter

Rating(s): AC110V/60HzCapacity: 30kgDivision: 1g

Items

Description

1 Sales territory Europe

2 Name

Counting Scale

3 Model

KF-H2C

4 Parameter

Rating(s): AC220-240V/50HzCapacity: 30kgDivision: 1g

Items

Description

1 Sales territory North America

2 Name

Counting Scale

3 Model

KF-H2C

4 Parameter

Rating(s): AC110V/60HzCapacity: 15kgDivision: 0.5g RS232

- 19 -

Manufacturer: Shanghaimuxinmuyeyouxiangongsi Address: Baoshanqu Shuangchenglu 803long 11hao 1602A-1609shi Shanghai EC REP: SHUNSHUN GmbH. Römeräcker 9 Z2021,76351 Linkenheim-Hochstetten, Germany Tel: +49 1727041930 euvertreter@gmail.com UK REP: Pooledas Group Ltd. Unit 5 Albert Edward House, The Pavilions Preston, United Kingdom Tel: 01772418127 pooledas123@gmail.com Imported to AUS: SIHAO PTY LTD. 1 ROKEVA STREETEASTWOOD NSW 2122 Australia Imported to USA: Sanven Technology Ltd. Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730 Made In China
- 20 -

Technical Support and E-Warranty Certificate www.vevor.com/support

