司顺工业设计
计数秤(sku4-sku10)说明书-20240105(用于生产) 1705022510194 Technical Support and E-Warranty Certificate www.vevor.com/support
Counting Scale USER MANUAL
MODEL: KF-H2C / KF-H2D
We continue to be committed to provide you tools with competitive price. "Save Half", "Half Price" or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and does not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are
actually saving half in comparison with the top major brands.
MODEL: KF-H2C / KF-H2D
COUNTING SCALE
(The picture is for reference only, please refer to the actual object)
NEED HELP? CONTACT US! Have product questions? Need technical support? Please feel free to contact us:
Technical Support and E-Warranty Certificate www.vevor.com/support
This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if there are any technology or software updates on our product.
-1-
A. Main Technical Function.
1. Function:
Auto zero; Counting; ADD; TARE; Backlight
2. Power
AC 220-240V (±10%) 50Hz ± 1 Hz AC 110V (±10%) 60Hz ± 1 Hz DC 6V / 4AH rechargeable battery
3. Power consumption
DC 38 mA DC 58 mAwith backlight
4. Watt0.4Wwith backlight 5. Low power alarm
When it show (
)means need to charge. If keep still using, it's easy to
broken the scale.
B. Technical Data
Capacity 1
capacity
(n)
(e) (d)
(max) (min) zero Tare(max) Overload(max+9e)
15000.0g 15000.0g 0.5g 0.5g 15000.0g 10g ±300g 0~15000.0g
15004.5g
30.000kg 30.000kg 1g 1g 30.000kg 20g ±600g 0~30.000kg
30.009kg
NotesFS= MAX WEIGHT d=division
Additional remark
When the division 1g, generally the unit is KG(e.g. 1g, 2g, 5g ),When the division<1g, generally the unit is G(e.g. 0.1g, 0.2g, 0.5g)
-2-
C. Operation instruction.
1. Before using
(1).Please put the scale on a flat and firm place. It can tighten or loose the four feet to make sure on the same level. there is a level ball on it. (2).Do not use it in hostile environments like strong wind and sunshine. (3).Please use the power supplier alone. (4).Don't put anything on the plate when you turn on. (5).When weighing, please try you best put the good on the center of the plate, don't over it. (6).Turn on the scale after 15-20 Minutes weighing is more better.
(7).Show
need to charge first.
2. Dispaly:
A: When the unit is KG, the Weight will display 0.000 as picture:
or
-3-
B:When the unit is G, the Weight will display 0.0 as picture:
or (1).WEIGHT
6 digital for the goods weight and add weight and the left digital can display[- ]
(2).UNIT WEIGHT
5 digital for the unit weight and times of add .the point is can change.
(3).QUANTITY
6digital for the pieces of the goods
3. Symbol" "
(1). or Net or Taremeans has been cut the weight of packing (2). or Zeromeans no weight (3).+ or M+means ADD (4). or Stable or ~: Means on stable (5).SMPLOWmeans sample is not enough. the weight of the sample on the plate is less than the weight of min sample, please add the pieces unit this symbol disappear. (6).QTYPST UWLOWWhen the pcs is low as you set, it will alarm and QTYPST UWLOW .
(7).
Means the power is low, need to charge.
Remark
High precision counting scale: Min sample weight = 20d Min unit weight = 0.2d ( d=division)
counting scaleMin sample weight = 40d Min unit weight= 0.8d ( d=division)
-4-
4. KEYBOARD
OR
(Without RS-232)
(with RS-232)
4.1 Composite key function description
+Number keys0--2convert units
+Numbers keys4--6adjust the brightness
+ set the upper and lower limits of alarmLong
Press to enter the alarm settingPress to closePress to set
the outside of the upper and lower limits of alarmPress to set the inside of
the upper and lower limits of alarmPress to set the upper limits of
alarmPress to confirm
4.2 Function key
: When the unit weight is unknownSet the number of items to be sampled
:When the unit weight is knownConfirm the input weight :Use this key to set the alarm value when a fixed number of alarms are required
-5-
:Disable alarm function
:Add up the quantity of goods :Cancel the total amount of the accumulated items :Remove the weight of tare :Return the scale to zero as far as possible :Clear the number :Print the current weight, single weight, quantity ,and the cumulative data(Note: with the RS232)
5. FUNCTION
5.1. ON-OFF Button
Put ON/OFF to"" means turn on.
Put ON/OFF to "O" Means power off.
5.2. Backlight Auto
Press , when it display "
"press
, I will display"
". Put the
goods on the plateweight >10d, the light is on auto, when it is zero , the light is
off auto.
Light on all the time
Press
when it display"
"press
it will display" ", Light on all
the time .
Light off all the time
press , when it display "
"Press
it will display " ", the light
off all the time.
When you turn off the scale, it will memory what you have choose
-6-
5.3.Kg/g/lb unit choose
Press
when is display"
" then press
, unit is "kg".
Press
when is display"
" then press , unit is "g".
Press
when is display"
" then press , unit is "lb".
5.4.Counting
5.4.1 Before counting, you need to get some samples to know the pcs or unit weight (1) When the unit weight is unknown
Put the samples of relevant goods on the plate (the weight of each sample must be the same): E.g. (A): when the unit is G, put 30pcs screws of each same weight on the plate, It will display:
Weight
Unit weight Total count
[ 53.1g ] [ 0 ]
[0 ]
Input the PCS "30" of the samples(Screws), it will display:
Weight
Unit weight Total count
[53.1g]
[30]
[0]
Then press , it will display:
Weight
Unit weight Total count
[53.1g ]
[1.77g]
[ 30 ]
At this moment you can continue to put the more goods (e.g.: screws) on the plate, the Total weight & Total count will change constantly, the unit weight won't be changed.
E.g. (B): when the unit is KG, put 30pcs screws of each same weight on the plate, It will display:
Weight
Unit weight Total count
[ 0.053kg ] [ 0 ]
[0 ]
-7-
Input the PCS "30" of the samples (Screws), it will display:
Weight
Unit weight Total count
[0.053kg]
[30]
[0]
Then press , it will display:
Weight
Unit weight Total count
[0.053kg ]
[1.766g]
[ 30 ]
At this moment you can continue to put the more goods (e.g. screws) on the plate, the Total weight & Total count will change constantly, the unit weight won't be changed.
(2) Know the unit weight(e.g. screws)
When you know the weight of one screw is 1.766g,
A: if the unit is G, Input the unit weight 1.766,it will display:
[0.0g]
[1.766g] [0]
Then Press , and put the more goods(e.g:30 pcs screws) on the plate,
[53.0g] [1.766g ] [30 ] If at this moment you continue to put the more pcs, the Total weight & Total count on the window will change constantly, the unit weight won't changed. B:If the unit is KG, Input the unit weight 1.766, it will display:
[0.000kg]
[1.766g] [0]
Then Press
, and put the more goods(e.g:30 pcs screws) on the plate,
[0.053kg] [1.766g ] [30 ]
Finally, when you take off all the goods on the plate, the unit window still
displays value, you can press
.
-8-
The sample is more ,the precision is more high
NULL POINT
When you using the scale , sometimes the weight window is not [0.0], you can
press
to make it into [ 0 .0] , Zero range =capacity ×+ 4%
5.4.2 Counting goods have packing
(1).When the packing box /carton weight is unknown (e.g. the unit is KG)
a. Put the packing box of 500g on the plate, it will display
[0.500kg]
[0 ]
[0]
b. Press
, It will display
OR At this moment you can follow 5.4.1 to continue the counting. When the packing box /carton weight is unknown (e.g. the unit is G) a. Put the packing box of 500g on the plate , It will display
[500.0g]
[0 ]
[0]
b. Press , it will display:
[0.0g]
[0 ]
[0]
-9-
Clear the TARE history Take down the goods and package on the plate, the weight will be [- 0.500kg ] on the basis of KG or [- 500.0g ] on the basis of G , Press , The weight will be [0.0], and this to TARE will disappear.
(2).1-A.When the weight of packing box/carton is known (e.g. the unit is KG) There is nothing on the plate, it display [0.000] [0] [0] The packing box is 500g, Input 500, it will display [0.000] [500] [0] Pres [TARE], it will display [-0.500] [----] [----] Then put that packing box on the plate, it will display 0.000(it means tared),
and at this moment you start to follow the way of 5.4.1 for counting. (3).1-B. When The weight of packing box/carton is known (e.g. the unit is G)
There is nothing on the plate, it display [0.0 g] [0] [0] The packing box is 500g, Input 5000, it will display [0.0g ] [5000] [0] Press , it will display [-500.0g] [----] [----]
Attention: when weight window display "0.0"(it means the unit is G), input the weight of packing box must be 10 times of the actual weight. (e.g:500g package box, you need to input 5000)
At this moment you can firstly put that packing box, it will display "0.0" on the basis of G or "0.000" on the basis of KG, it means both are tared. Then start to follow the step of 5.4.1 to continue the counting. There is some goods including the packing box/carton on the plate.
- 10 -
E.g. Packing box is 500g, on the basis of KG, packing box(500g)+goods(30PCS screws)= 0.553kg , it will display
[ 0.553kg] [0] [0]
Input the weight 1.766 of one screw, press , it will display
[0.553kg] [1.766g] [313]
Input 500( packing box is 500g),press , it will display
[0.053kg] [1.766g] [30] E.g. Packing box is 500g, on the basis of G, packing box(500g)+goods(30PCS screws)= 553.1g , it will display
[ 553.0g] [0] [0]
Input the weight 1.766 of one screw, press , it will display
[553.0g] [1.766g] [313]
Input 5000( actual packing box is 500g), Press the key , it will display
[53.0g] [1.766g] [30] Attention: When weight window display "0.0" (it means the unit is G), input the weight of packing box must be 10 times of the actual weight.(e.g:500g package box, you need to input 5000) Clear the TARE history
Take down the goods and package on the plate, the weight will be [-
0.500kg ], press ,The weight will be [0.0].
5.5. ADD
99Times ADD, 6 Digital
5.5.1 Quantity ADD of repeatedly counting
5.1.1.1 PCS ADD
Put the goods on the plate ,follow as 5.4.1 counting, then press
, Repeat
5.1.1.1, then press
,on the unit weight window will show [2] , it means, 2
- 11 -
times ADD. THE Total COUNT(PCS) will show the two times pcs.(e.g. put 10pcs
screws on the plate, input 10,press SMPL, press
one time, then take off
10pcs screws, put again another 10 pcs screws, press
again. The total count
will display that 20 pcs that they are 1st time's and count of 2nd time's, of course,
the total weight is 1st time +2nd time)
When you finish the counting of all goods, there is no goods on the plate, Press
to check the total weight and times and quantities. Press
and
to
clear the ADD history.
5.5.2 Weight ADD
E.g. the unit is G
Put the goods on the plate like 500g, press
It will display [500.0] [1] [0] for 5 seconds, then to [500.0] [0] [0]
Then take off the goods, put another good s on the plate like 100g, press
It will display [600.0g] [2] [0] for 5 seconds, then to [100.0g] [0] [0].
But when you take off those goods, press
again, you can just check the
total value still is: [600.0g] [2] [0], of course, you can continue to put the
new goods on it, press for counting.
Finally when you finish ADD , there is no goods on the plate, Press
to
check the total weight .Press
to clear the ADD history.
E.g. the basis is KG
Put the goods on the plate Like 500g, press
It will display [0.500kg] [1] [0] for 5 seconds, then to [0.500] [0] [0]
Then take off the goods, put another good s on the plate like 100g, press
It will display [0.600kg] [2] [0] for 5 seconds, then to [0.100g] [0] [0].
- 12 -
But when you take off those goods, press
again, you can just check the
total value still is: [0.600kg] [2] [0], of course, you can continue to put the new
goods on it, press
for counting.
Finally when you finish ADD, there is no goods on the plate, Press
to
check the total weight . Press
to clear the ADD history.
5.6. Quantity alarm
E.g. If over the goods of 30pcs on the plate, you want alarm.
Firstly Input 30 pcs, press
,It will display
[0.000] [0] [30] for 3 second,
then display [0.000] [0] [0]
Put the goods on the plate, when counting(follow the way of 5.4.1 e.g: put 10pcs
goods on the plate, input 10,press
, then continue to put more goods on
it),when the pcs over 30pcs it will alarm.
Press
and
to cancel quantity alarm.
5.7. Calibration
1.Turn on the scale, when the window displays "0", input 52411 and press
key to enter into calibration mode.
2. Press
to choose max capacity, press to confirm, for example:
30kg,input "30000", press to confirm
3.Press
to choose division, press to confirm, for example, when you
press
continuously , it will display"1,2,5,10,", then you choose the division
you need. Then press .
- 13 -
4.Press
to choose position of point, after pressing constantly, it displays
"0""1""2""3""4""0" you can choose the position you need, then press
to confirm."0"means "0", "1"means "0.0" "2"means "0.00", "3"means "0.000" ,
"4"means "0.0000" If you don't need change capacity, division and point, you can
could directly press
to enter next step
5.Weight window will show the data which poise will load on scale(If you what change load poise , you could input the data you will load on scale). press
,the unit price window will display "LOAD" , then put load/weight , finally press
to confirm.
5.8. Upper and Lower Limit Alarms
5.8.1 Selecting Alarm Types
Long-press the
key to enter the settings. The single weight window displays:
Pressing
shows OFF to disable, pressing
shows OUT for out-of-range
alarm, pressing
shows IN for in-range alarm, and pressing
shows UP
for upper limit alarm only. Press
to save and exit.
Short-press the
key to set the quantity upper limit.
5.8.2Inputting Alarm Values (Note: Long-press the
key to activate the alarm,
same as the first step above)
Short-press the
key to enter settings, displaying (A-FF-O-dn). Choose and
input the lower limit value, then input the upper limit value. The weight window displays alarm types: A-OUT indicates out-of-range alarm, A-IN indicates in-range alarm, A-UP indicates upper limit alarm only.
- 14 -
A. When the quantity window displays DN, input the lower limit value, press to confirm and proceed to the next step. B. When the single weight window displays UP, input the upper limit value, press
to confirm and exit.
5.8.3Press
To deactivate the alarm and reset the upper and lower limit
values.
5.9.Printing Function (Note: with the RS232)
5.9.1Single Print
When the weight is not zero, press the weight, and quantity. 5.9.2Add Print
key to print the current weight, single
When multiple weights are accumulated, press the
key to directly print
the accumulated information. After finishing, the cumulative data is automatically cleared.
6.RS232 Connection Computer(Note: with the RS232)
Through the RS232 line to connect the electronic scale with the computer
successfully,press the
key to send the current weight, single weight, and
quantity.
7. Attention:
1. Keep away from the rain and washing by waterif is happen, please dry it, and find it can not work, return to the seller to repair).
2. Please do not store in the high temperature and wet place. 3. Do not let insect into the body. 4. Do not heavy shock and overload. 5. No need using for long time. please clear it, and take it into the bag, and
charge it each 3 months. Recharge it before using .
- 15 -
6. If you have good advise please feel free to tell us.
8.Common trouble shooting:
No TROUBLE
MEANS
REASON
Turn
LOW
1
on ,show"LB " and alarm
BATTERY(POWER)
Turn 2 on ,show"ED WEIGHING ERROR
"
Battery no power
Battery broken
LOAD CELL LINE SEALING -OFF
LOAD CELL TOUCH WITH SOMETHING
LOAD CELL BROKEN
PCB BROKEN
too WET
TOO DURTY
3
Turn on ,hop counting
The weight window number on changing
cannot weighing
LOAD CELL TOUCH WITH SOMETHING LOAD CELL LINE
SEALING -OFF
LOAD CELL BROKEN
When
The weight window
4 charging ,co number on changing
unting
cannot charging
PCB BROKEN Adaptor
Digital 8 not
5
full show
Digital 8 not full show ,or less
electronic circuit short LCD Broken
Drive broken
the key be stucked
the key can not spring
back
key can not press the key can not
6
working
working
key electronic circuit short
PCB BROKEN
KEY BOARD
CORRODE
7 NO WEIGHT
no any weight
the load cell line and PCB link broken
ADVISE RECHARGING
change the battery
RE-SEALING
CHECKING
CHANGE THE LOAD CELL
CHANGE THE PCB DRY the PCB and load
cell take down the PCB, using Alcohol cleaning
first ,then dry it
CHECKING
RE-SEALING
CHANGE THE LOAD CELL
CHANGE THE PCB
change the adaptor
using rubber-insulated wire link together change the LED
change the display board checking
changing the key
using rubber-insulated wire link together
CHANGE THE PCB CHANGE THE KEY
BOARD
checking
- 16 -
can not turn
press the on/off
8
on
button ,can not turn on
when turn on
DI DI DI
when turn on DI DI DI
9 sound all the
sound all the time
time
turn on the sound
10 normal,but no words
turn on 11 show"8"all
the time
turn on the sound normal,but no words
when turn on the scale,all the window
show 8,can not weighing,and the sound it is normal When charging AC light is working,but can not charge
can not
12
recharge
When charging AC light is not working,
no backlight 13 for the LCD
Turn on ,there is no light for the LCD
LOAD CELL LINE SEALING -OFF
LOAD CELL BROKEN PCB BROKEN
the ON/OFF BUTTON BROKEN
CHECK THE BATTERY POWER IS ENOUGH
PCB BROKEN CHECK THE BATTERY POWER IS ENOUGH
PCB BROKEN check the displaybord to
PCB link is ok display board broken check the displaybord to
PCB link is ok
display board broken
Adaptor Battery broken
adaptor adaptor plug charging connect broken the charging connect to the PCB link off PCB BROKEN Battery broken power save function check the LCD part if have sealing-off LCD Broken
RE-SEALING
CHANGE THE LOAD CELL
CHANGE THE PCB CHANGE THE ON/OFF
BUTTON LOW
VOLT ,RECHARGE
BATTERY BROKEN CHANGE IT ,V<5.25V
CHANGE THE PCB LOW
VOLT ,RECHARGE BATTERY BROKEN CHANGE IT ,V<5.25V CHANGE THE PCB
turn off , relink the display board link
change the display board
turn off , relink the display board link
change the display board
change the adaptor
change the battery
change the adaptor take down recharging change the connect part
re sealing
CHANGE THE PCB change the battery reset the backlight on
function
RE-SEALING
CHANGE THE LCD
- 17 -
Items
Description
1 Sales territory North America
2 Name
Counting Scale
3 Model
KF-H2D
4 Parameter
Rating(s): AC110V/60HzCapacity: 30kgDivision: 1gRS232
Items
Description
1 Sales territory North America
2 Name
Counting Scale
3 Model
KF-H2C
4 Parameter
Rating(s): AC110V/60HzCapacity: 30kgDivision: 1gRS232
Items
Description
1 Sales territory Europe
2 Name
Counting Scale
3 Model
KF-H2C
4 Parameter
Rating(s): AC220-240V/50HzCapacity: 30kgDivision: 1g RS232
Items
Description
1 Sales territory Australia
2 Name
Counting Scale
3 Model
KF-H2C
4 Parameter
Rating(s): AC220-240V/50HzCapacity: 30kgDivision: 1g RS232
- 18 -
Items
Description
1 Sales territory North America
2 Name
Counting Scale
3 Model
KF-H2C
4 Parameter
Rating(s): AC110V/60HzCapacity: 30kgDivision: 1g
Items
Description
1 Sales territory Europe
2 Name
Counting Scale
3 Model
KF-H2C
4 Parameter
Rating(s): AC220-240V/50HzCapacity: 30kgDivision: 1g
Items
Description
1 Sales territory North America
2 Name
Counting Scale
3 Model
KF-H2C
4 Parameter
Rating(s): AC110V/60HzCapacity: 15kgDivision: 0.5g RS232
- 19 -
Manufacturer: Shanghaimuxinmuyeyouxiangongsi Address: Baoshanqu Shuangchenglu 803long 11hao 1602A-1609shi Shanghai EC REP: SHUNSHUN GmbH. Römeräcker 9 Z2021,76351 Linkenheim-Hochstetten, Germany Tel: +49 1727041930 euvertreter@gmail.com UK REP: Pooledas Group Ltd. Unit 5 Albert Edward House, The Pavilions Preston, United Kingdom Tel: 01772418127 pooledas123@gmail.com Imported to AUS: SIHAO PTY LTD. 1 ROKEVA STREETEASTWOOD NSW 2122 Australia Imported to USA: Sanven Technology Ltd. Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730 Made In China
- 20 -
Technical Support and E-Warranty Certificate www.vevor.com/support