Installation Manual - Alpine Home Air Products

Installation Manual. GeneralAire Models MAC 1400, MAC 2000, & MAC 2020. Media Air Cleaners. For installation in the return air duct of any forced air ...

GeneralAire MAC1400 Media Air Cleaner, 7W x 26 1/8D x 17 5/16H Inch, MERV 10

GeneralAire MAC2000 Media Air Cleaner, 7W x 26 1/8D x 21 1/8H Inch, MERV 11

PDF preview unavailable. Download the PDF instead.

14064 MAC Installation Manual 1400 2000 20203
GENERAL FILTERS
INCORPORATED

Air Cleaners (GFI #4510, 4500, & GFI#4530)
Installation Manual

GeneralAire® Models MAC 1400, MAC 2000, & MAC 2020

Media Air Cleaners

For installation in the return air duct of any forced air heating and cooling system

Please Leave This Manual With The Homeowner

Date of Installation:______________Installed by:___________________Installer Phone:_________________
Place Serial Number Sticker Here:
· Installation by anyone other than a qualified contractor voids the warranty. · Modification or alteration of product, parts, installation instructions or local safety codes voids warranty.
· Read our full warranty policy at the end of this document.

MERV 11 Air Cleaners
75% Dust Spot Efficiency 1.0 to 3.0 Microns

MAC 2020
Form No. 14064 Rev. A

MAC 2000

MAC 1400

Manufacturers of Whole House Residential Indoor Air Quality Products. Humidifiers - Dehumidifiers - Air Cleaners - UV Air Purifiers - Heat/Energy Recovery Ventilators
1 USA: www.GeneralFilters.com Canada: www.CGFProducts.com

Installation Instructions

IMPORTANT: A 22 Inch Clearance Must Be Allowed For Removal Of The Media Cartridge

From The Cabinet.

Pressure Drop Schedule

1. Turn off electricity to furnace.

2. Remove front cover. 3. Slide media cartridge from air cleaner cabinet, and discard packing
material. 4. Remove and discard existing furnace air filter.

CFM IN W.C. MAC 2000

IN W.C. MAC 1400 MAC 2020

5. Install cabinet in return air system. 6. Properly install airflow direction arrows on interior of cabinet. Duct

600

0.04

0.07

supports are recommended to support weight of cabinet. See typical

800

0.06

0.11

installations.

1000

0.08

0.16

7. Slide the media cartridge into the cabinet. Be sure the airflow arrow

1200

0.11

0.22

on the cartridge is in the same direction as the arrow in the cabinet.

1400

0.14

0.28

The wire mesh is always on the downstream side of the filter media.

1600

0.17

Replace cover.

1800

0.21

8. If a condition indicator is to be used, install on a vertical duct surface between the air cleaner and the furnace blower.

2000

0.26

9. Turn on electricity and furnace and check performance of all equipment.

WARM AIR

RETURN AIR

RETURN AIR

RETURN AIR

WARM AIR

GeneralAire MAC Air Cleaner

GeneralAire MAC Air Cleaner

GeneralAire Flow Through Humidifier

HIGH BOY

GeneralAire MAC Air Cleaner

WARM AIR

COUNTER-FLOW

WARM AIR

LOW BOY

! IMPORTANT:
Ensure Proper Clearance For Removal Of The Media Cartridge From the Cabinet

· MAC 1400 26 Inches

· MAC 2000 26 Inches

· MAC 2020 22 Inches

D

Dimensions
· MAC 1400 · MAC 2000 · MAC 2020

17 5/16" H x 26 1/8" D x 7" W 21 1/8" H x 26 1/8" D x 7" W 21 5/16" H x 22 5/8" D x 7" W

Depth measurement includes door.

2

H W

Maintenance

The air cleaner media will normally need to be replaced every 4 to 6 months (end of the heating or cooling season) with normal usage. If an air cleaner condition indicator is used, change the media when the device indicates that service is required. Additionally, the frequency of filter replacement can be determined by visual examination.

Parts

Cabinet Filter Cartridge Media

Filter Access Door

Replacement
MAC 1400 MAC 2000 MAC 2020

Filter Cartridge Media Filter Access Door

GFI #4541 MERV 11 GFI #4551 MERV 11 GFI #4556 MERV 11

14056 14018 14018

Cabinet
14021 14001 14172

Warranty

This air cleaner, if properly registered on line at www.generalfilters.com is warranted to the consumer against defects in materials and workmanship for a period of ten years from the date of installation. The air cleaner media is not covered by this limited warranty or any other warranties.
Any other defective parts will be repaired without charge except for removal, reinstallation and transportation costs. To obtain repair service under this limited warranty, the consumer must send the defective part or the complete unit to the manufacturer.
There are no express warranties covering this air cleaner other than as set forth above, the implied warranties of merchantability and fitness for a particular purpose are expressly excluded. The manufacturer assumes no liability in connection with the installation or use of this product, except as stated in this limited warranty. The manufacturer will in no event be liable for incidental or consequential damages.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow either limitations on implied warranties, or exclusions from incidental or consequential damages, so the above exclusion and limitation may not apply to you. Any questions pertaining to this limited warranty should be addressed to the manufacturer. U.S.A.: The manufacturer has elected not to make available the informal dispute settlement mechanism which is specified in the Magnuson-Moss Warranty Act.)

If you do not have on-line access, please mail a postcard with your name, phone number, email address, product purchased, model number, date of purchase, serial number, and contractor contact information to:

USA:

General Filters, Inc. 43800 Grand River Ave Novi, MI 48375 www.GeneralFilters.com Toll Free (866) 476-5101

Canada:

400 Midwest Road Toronto, ON, M1P 3A9 Canada www.CGFProducts.com Toll Free (888) 216-9184

3


Adobe PDF Library 9.9 Adobe InDesign CS5 (7.0)