MEAN WELL LOP-200 Series: 200W Low Profile Open Frame Power Supply
Model: LOP-200 Series
Description: A highly reliable, energy-efficient, low-profile open frame power supply with a 4"x2" compact size and a height of 25.4mm.
Key Features
- MEAN WELL Patent Number: ZL 202223277512.1
- 4"x2" compact size with low profile (25.4mm)
- 80~264Vac universal input with PFC
- No load power consumption <0.5W
- Global certificates in multi-fields: ITE (62368-1), Medical (60601-1), Household (60335-1), Industrial (61558-1/-2-16)
- 150% peak load @ 3s
- 140W convection cooling, 200W with optional fan (10.98CFM)
- Suitable for Class I or Class II installations
- Over voltage category III (OVC III)
- Wide operating temperature range: -40 ~ +80°C
- High efficiency up to 94%
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Extremely low leakage current (2 x MOPP), suitable for BF medical applications
- Operating altitude up to 5000 meters
- Built-in 12V/0.5A auxiliary output for external FAN
- 3 years warranty
Applications
- Industrial automation machinery/control systems
- Security systems
- Mechanical and electrical equipment
- Electronic instruments, equipment, or apparatus
- Network equipment
- Telecom devices
- Power sourcing equipment of PoE
- Home automation
- Medical devices
Specifications Overview
Model | DC VOLTAGE | CURRENT (Peak/10.98CFM/Convection) | RATED POWER (Peak/10.98CFM/Convection) | RIPPLE & NOISE (max.) | VOLTAGE ADJ. RANGE | VOLTAGE TOLERANCE | LINE REGULATION | LOAD REGULATION | EFFICIENCY (Typ.) |
---|---|---|---|---|---|---|---|---|---|
LOP-200-12 | 12V | 25A / 16.7A / 11.7A | 300W / 200.4W / 140.4W | 120mVp-p | 11.4~12.6V | ±3.0% | ±0.5% | ±1.0% | 93% |
LOP-200-15 | 15V | 20A / 13.4A / 9.4A | 300W / 201W / 141W | 150mVp-p | 14.3~15.8V | ±3.0% | ±0.5% | ±1.0% | 93% |
LOP-200-18 | 18V | 16.7A / 11.1A / 7.8A | 300.6W / 199.8W / 140.4W | 180mVp-p | 17.1~18.9V | ±3.0% | ±0.5% | ±1.0% | 93.5% |
LOP-200-24 | 24V | 12.5A / 8.4A / 5.9A | 300W / 201.6W / 141.6W | 200mVp-p | 22.8~25.2V | ±2.0% | ±0.5% | ±1.0% | 94% |
LOP-200-27 | 27V | 11.1A / 7.5A / 5.3A | 299.7W / 202.5W / 143.1W | 200mVp-p | 25.6~29V | ±1.0% | ±0.5% | ±1.0% | 94% |
LOP-200-36 | 36V | 8.3A / 5.6A / 3.9A | 298.8W / 201.6W / 140.4W | 250mVp-p | 34.2~37.8V | ±1.0% | ±0.5% | ±1.0% | 94% |
LOP-200-48 | 48V | 6.3A / 4.2A / 3.0A | 302.4W / 201.6W / 144W | 250mVp-p | 45.6~50.4V | ±1.0% | ±0.5% | ±1.0% | 94% |
LOP-200-54 | 54V | 5.6A / 3.8A / 2.7A | 302.4W / 205.2W / 145.8W | 250mVp-p | 52~58V | ±1.0% | ±0.5% | ±1.0% | 94% |
Input Specifications
- Voltage Range: 80~264Vac
- Frequency Range: 47~63Hz
- Power Factor: PF>0.95/230Vac, PF>0.98/115Vac at full load
- AC Current: 2.5A/115Vac, 1A/230Vac
- Inrush Current (Typ.): Cold Start 40A/115Vac, 80A/230Vac
- Leakage Current: Earth leakage current < 500μA(rms) @ 264Vac, touch current < 70μA(rms) @ 264Vac
Safety & EMC
Safety Standards
- CB: IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1
- TUV: BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN60601-1(3.2 Version)
- UL: UL62368-1, ANSI / AAMI ES60601-1(3.2 Version)
- CCC: GB4943.1
- RCM: AS/NZS 61558-1/-2-16
- EAC: TPTC 004 approved
Isolation Resistance
- Primary-Secondary: 2xMOPP
- Primary-Earth: 1xMOPP
- Secondary-Earth: 1xMOPP
Over Voltage Category
- IEC/EN 61558-1/-2-16: OVC III (altitude up to 2000M)
- IEC/EN/UL 62368-1: OVC II (altitude up to 5000M)
- IEC/EN 60335-1: OVC II (altitude up to 5000M)
- IEC/EN 60601-1: OVC II (altitude up to 4000M)
EMC Emission
Parameter | Standard | Test Level / Note |
---|---|---|
Conducted & Radiated | BS EN/EN55032 (CISPR32) BS EN/EN55011 (CISPR11) BS EN/EN55014 (CISPR32) | Class I: Class B, Class II: Class A |
Harmonic Current | BS EN/EN61000-3-2 | Class A |
Voltage Flicker | BS EN/EN61000-3-3 | Class I: Class B |
EMC Immunity
Parameter | Standard | Test Level / Note |
---|---|---|
ESD | BS EN/EN61000-4-2 | Level 4, 15KV air; Level 4, 8KV contact |
Radiated Susceptibility | BS EN/EN61000-4-3 | Level 3, 10V/m (80MHz~2.7GHz) Table 9, 9~28V/m (385MHz~5.78GHz) |
EFT/Burest | BS EN/EN61000-4-4 | Level 3, 2KV |
Surge | BS EN/EN61000-4-5 | Level 4, 4KV/Line-FG; 2KV/Line-Line |
Conducted | BS EN/EN61000-4-6 | Level 3, 10V |
Magnetic Field | BS EN/EN61000-4-8 | Level 4, 30A/m |
Voltage Dips and interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 100% dip 1 period, 30% dip 25 periods, >95% interruptions 250 periods |
Mechanical Specification
(Unit: mm, tolerance ± 1mm)
Dimensions: 101.6mm (Length) x 50.8mm (Width) x 25.4mm (Height)
AC Input Connector (CN1): JST B3P-VH or equivalent
- Pin 1: AC/L
- Pin 2: No Pin
- Pin 3: AC/N
DC Output Connector (CN2): JST B6P-VH or equivalent
- Pins 1,2,3: +V
- Pins 4,5,6: -V
FAN Connector (CN101): JST B2B-PH-K-S or equivalent
- Pin 1: +12Vaux
- Pin 2: DC COM
Note:
- Class I System: Mounting holes marked with ⏚ have to be connected to safety earth.
- Class II System: Unnecessary to connect with safety earth.
Installation Manual: Please refer to: http://www.meanwell.com/manual.html
Block Diagram
The block diagram illustrates the power supply's internal structure, including EMI filter, rectifier and PFC, power switching, and output rectifiers and filters, along with control and detection circuits for protection features like OLP, OVP, and OTP.
Derating Curve
The derating curve shows the maximum output power based on ambient temperature. For free air convection, the maximum output power is 140W. When force-cooled with an external fan (10.98CFM), the maximum output power is 200W. The curve indicates that operation is possible from -40°C to +80°C, with specific derating required at higher temperatures.
Output Derating VS Input Voltage
This graph illustrates how the output power derates based on the input voltage. The power supply operates efficiently across a wide input voltage range from 80VAC to 264VAC.
Other Specifications
- MTBF: 2928.9K hrs min. (Telcordia SR-332), 393.9K hrs min. (MIL-HDBK-217F @ 25°C)
- Packing: 36pcs/10Kg/0.95CUFT