1. General Information

1.1. Legal Information

The contents of this document are provided "as is". Except as required by applicable law, no warranties of any kind are made in relation to the accuracy and reliability or contents of this document, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.

Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.

More information about Westermo can be found at www.westermo.com.

1.2. About This Guide

This guide is intended for installation engineers and users of the Westermo products. It includes information on safety and regulations, a product description, installation instructions and technical specifications.

1.3. Software Tools

Related software tools are available at www.westermo.com/support/software-tools.

1.4. License and Copyright for Included FLOSS

This product includes software developed by third parties, including Free/Libre Open Source Software (FLOSS). The specific license terms and copyright associated with the software are included in each software package respectively. Please visit the product web page for more information.

Upon request, the applicable source code will be provided. A nominal fee may be charged to cover shipping and media. Please direct any source code request to your normal sales or support channel.

2. Safety and Regulations

2.1. Warning Levels

Warning signs are provided to prevent personal injuries and/or damages to the product. The following levels are used:

Level of warningDescriptionConsequence personal injuryConsequence material damage
[!] WARNINGIndicates a potentially hazardous situationPossible death or major injuryMajor damage to the product
[!] CAUTIONIndicates a potentially hazardous situationMinor or moderate injuryModerate damage to the product
[!] NOTICEProvides information in order to avoid misuse of the product, confusion or misunderstandingNo personal injuryMinor damage to the product
[i] NOTEUsed for highlighting general, but important informationNo personal injuryMinor damage to the product

2.2. Safety Information

Before installation:

Read this manual completely and gather all information available on the product. Make sure it is fully understood. Check that your application does not exceed the safe operating specifications for the product.

[!] WARNING - SAFETY DURING INSTALLATION The product must be installed and operated by qualified service personnel and installed into an apparatus cabinet or similar, where access is restricted to service personnel only. For Ibex products, outdoor installation is allowed.

During installation, ensure a protective earthing conductor is first connected to the protective earthing terminal (only valid for metallic housings). Westermo recommends a cross-sectional area of at least 4 mm².

Upon removal of the product, ensure that the protective earthing conductor is disconnected last.

[!] WARNING - HAZARDOUS VOLTAGE Do not open an energised product. Hazardous voltage may occur when connected to a power supply.

[!] WARNING - PROTECTIVE FUSE The power supply wiring must be sufficiently fused. It must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.

[!] WARNING - POWER SUPPLY CONNECTION There are safety regulations governing the power source that can be used in conjunction with the product. Refer to Interface Specifications.

[!] WARNING - RADIO PRODUCTS Observe the usage limitations of radio products at filling stations, in chemical plants, in systems with explosives or potentially explosive locations.

The product may not be used in airplanes. Exercise particular caution near personal medical aids, such as pacemakers and hearing aids. Never perform work on the antenna system during a thunderstorm.

To fulfill human safety, a minimum separation distance of 20 cm or more should be maintained between the antenna of the product and personnel during operation.

[!] CAUTION - HOT SURFACE Be aware that the surface of this product may become hot. When it is operated at high temperatures, the external surface may exceed Touch Temperature Limit according to the product's relevant electrical safety standard.

This product complies with Touch Temperature Limits throughout its operational temperature range.

[!] CAUTION - CORROSIVE GASES If the product is placed in a corrosive environment, it is important that all unused connector sockets are protected with a suitable plug, in order to avoid corrosion attacks on the gold plated connector pins.

[!] CAUTION - CABLE TEMPERATURE RATING FOR FIELD TERMINAL WIRES There may be a requirement on the minimum temperature rating of the cable to be connected to the field wiring terminals, see Interface Specifications.

2.3. Care Recommendations

Follow the care recommendations below to maintain full operation of the product and to fulfill the warranty obligations:

If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired.

If the product is not working properly, contact the place of purchase, the nearest Westermo distributor office or Westermo technical support.

[i] NOTE Devices not used shall be kept in the factory sealed moisture barrier bag. Open, unsealed devices should not be kept unpowered for more than 30 days.

2.4. Product Disposal

This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.

By ensuring the product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both the environment and human health, which could be caused by inappropriate disposal.

Figure 1. WEEE symbol for treatment of product disposal

2.5. Compliance Information

[!] REGULATORY NOTICE Any changes or modifications shall be approved by the party responsible for compliance. If not, users could void the user's authority to operate the equipment. Country code and antenna gain need to be set properly for correct functionality in the installed country.

2.5.1. Agency Approvals and Standards Compliance

Approvals and StandardsDescriptionTest levels
ClimateEN 50155, class OT4 Railway applications - Electronic equipment used on rolling stock
EMCEN 50155, Railway applications - Electronic equipment used on rolling stock
EBA EMV 06, German Federal Railway Authority, Radio compatibility of rail vehicles (valid for LV models only)
EN 50121-3-2, Railway applications – Electromagnetic compatibility, Part 3-2: Rolling stock – Apparatus
ETSI EN 301 489-1, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment and services - Part 1: Common technical requirements
ETSI EN 301 489-19, Electromagnetic Compatibility (EMC) standard for radio equipment and services - Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band
ETSI EN 301 489-24, Electromagnetic compatibility (EMC) and Radio spectrum Matters (ERM) for radio equipment and services - Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for Mobile and portable (UE) radio and ancillary equipment
ETSI EN 301 489-52, Electromagnetic Compatibility (EMC) standard for radio equipment and services - Part 52: Specific conditions for Cellular Communication Mobile and portable (UE) radio and ancillary equipment
ECE E-Mark, Road Vehicles, E13 10R-06 15771 (valid for LV models only)
Mechanical (Shock and vibration)EN 61373, category 1, class A and B
IEC 60068-2-27, 100 m/s², 30 ms
MIL STD 810G Method 516.7, 10 g, 11 ms
Insulation (Coordination and test)EN 50124-1, Railway applications – Insulation coordination
EN 50155, Railway applications - Electronic equipment used on rolling stock
Radio communicationETSI EN 301 908-1, IMT cellular networks
3GPP LTE Advanced standard
FCC-47-15, Radio frequency devices
FCC-47-22, Public mobile services
FCC-47-24, Personal communications services
FCC-47-27, Miscellaneous wireless communications services
SafetyEN/IEC 62368-1, Safety Requirements for audio/video, information and communication technology equipment
EN 45545-2, Fire protection on railway vehicles
NFPA 130, Fire protection for fixed guideway transit and passenger rail system

2.5.2. United States - FCC

The enclosed product complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this product may not cause harmful interference and (ii.) this product must accept any interference received, including interference that may cause undesired operation.

To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this product and persons during operation. To ensure compliance, operations at closer distances than this are not recommended.

This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This product generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the product off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

[i] NOTE This product contains FCC ID XMR201901EM12G (LTE).

2.5.3. United States - AREMA

The product has been tested according to AREMA Part 11.5.1 and 11.5.2 environmental class I and exposure class Internal.

2.5.4. Canada - IC

This product complies with Industry Canada's license-exempt RSSs. Operation is subject to the following two conditions:

Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:

[i] NOTE This product contains the IC Certification number 10224A-201901EM12G (LTE).

2.5.5. Simplified Declaration of Conformity

Hereby, Westermo declares that this product is in compliance with applicable EU directives and UK legislations. The full declaration of conformity and other detailed information is available at www.westermo.com/support/product-support.

Figure 2. The European Conformity and the UK Conformity Assessment markings

3. Product Description

3.1. Product Description

The Ibex-RT-330 is an EN50155 LTE router, developed for demanding industrial and railway applications. It makes full use of the 3G and 4G cellular networks.

The device utilizes a high performance GNSS receiver with concurrent reception of up to 3 GNSS signals from GPS, Galileo, GLONASS or BeiDou systems.

Figure 3. Ibex-RT-330 block diagram: The diagram shows a block representation of the Ibex-RT-330 router. Key components include Power Supply, LTE 4G module, CPU, GNSS receiver, and two Gigabit Ethernet ports (X1, X2). Antenna ports (A1, A2, A3) are also indicated.

The Westermo configuration management tool, WeConfig, can be used for discovery and basic configuration and maintenance. The configuration can be done via SNMP or via WebGUI. The status information is available in local LED status indicators, and through SNMP/WebGUI.

The Mobile Communication Gateway router is designed to withstand tough onboard environmental conditions and can be remotely managed using web browser or SNMP management tools.

Integrating hardware, software and network design support tools, this router platform offers advanced capabilities, the lowest total cost of ownership and will create the most reliable and resilient networks.

The router is engineered to maintain uninterrupted data communication, even in exceptionally harsh environments. Tested and certified to withstand extreme temperatures, vibrations and shocks, these routers only use industrial grade components which contributes towards a market leading mean time between failure (MTBF), maximized service life, and reduced operational and life cycle costs.

3.2. Available models

Art. no.ModelPoE PortRated current
3623-0740Ibex-RT-330-LVX224 VDC
3623-0741Ibex-RT-330-HV72-110 VDC

3.3. Hardware Overview

3.3.1. Frontside Overview

Figure 4. Frontside Overview: Depicts the front panel of the Ibex-RT-330 router, showing numbered interface ports and LED indicators.

No.DescriptionNo.Description
1LED indicators2SIM card slot
3Gigabit Ethernet ports X1 and X24Protective earth terminal
5Power input DC6Frontside label
7Warning symbol for surface temperatures above +60°C8Antenna ports A1 to A3

3.3.2. Front Side Label

Figure 5. Front Side Label: Shows the label on the front of the unit with details such as model type (Ibex-RT-xxx-xx EU), power specifications (24VDC, 0.6A), article number (3623-075001), and manufacturing date/batch information.

3.3.3. Rear Side Label

Figure 6. Rear Side Label: Displays the label on the rear of the unit, including Type (Ibex-RT-xxx-xx EU IP66), Art. No., NPN, Max current, Power, Country of Origin (Switzerland), FCC/IC e-label information with a default IP address, and manufacturer details (Westermo Neratec AG).

3.3.4. Interface Ports View

Figure 7. Interface Ports View: Illustrates the rear and side views of the router, highlighting various ports. Table 5 lists these ports: 1. Antennas, 2. SIM, 3. 1000Base-T, 4. Grounding point, 5. Power.

3.4. Connector Information

3.4.1. Power Input Connection

Table 6. M12 A-coded 4-pin male power connector according to IEC 61076-2-101: Details the pinout for the DC power input.

MarkingPositionDirectionDescription
DC1+DCPositive terminal
2-
3-DCNegative terminal
4-
HousingShieldChassis of product (ground)

[i] NOTE If the product is powered by PoE, the protective dust cap which is part of the delivery must be closed to protect the power interface from water or dust ingress.

3.4.2. SIM Card Slot

Figure 8. SIM card slot: Shows the location of the SIM card slot on the unit.

To remove the SIM card drawer, untighten the two knurled screws until they are loose and not anymore connected to the unit frame. Carefully move the drawer out of the frame. Place the SIM cards into the sockets in slot 1 and/or slot 2 with the contacts facing down. Let chamfered corners align according markings on the drawer.

Put the SIM card drawer back into the unit, ensuring that it fits into place and tighten the knurled screws on both sides until the drawer is fully inserted and plane with the unit frame.

[!] NOTICE To use the device in its specified temperature range it is important to use a robust industrial SIM card with extended temperature range.

[!] NOTICE In order to guarantee proper IP against dust and water, please check carefully that the drawer is fully inserted and screws are properly tightened.

[!] NOTICE Before removing and inserting the SIM drawer, ensure that power has been turned off by removing the power connector from the unit.

[i] NOTE The sim cards must be fully inserted into the sockets until the mechanical stop.

[i] NOTE The product supports two SIM cards with the restriction that only one SIM card is active.

3.4.3. Ethernet Ports

The product includes two Ethernet ports X1 and X2 which supports auto-negotiated 10 Mbit/s, 100 Mbit/s and 1000 Mbit/s operation. Automatic MDI/MDIX crossover is supported for 10BASE-T, 100BASE-T, 1000BASE-T operation.

Table 7. M12 X-coded 8-pin female Ethernet connector according to IEC 61076-2-109: Details the pinout for the Ethernet ports.

MarkingPositionDirectionDescription
X1/X21In/OutDA+
2In/OutDA-
3In/OutDB+
4In/OutDB-
5In/OutDD+
6In/OutDD-
7In/OutDC-
8In/OutDC+
HousingShieldChassis of product (ground)

Table 8. Ethernet PoE connection on X2 (LV-model only): Details the PoE connection for the LV model.

[i] NOTE PoE is supported on X2 for the LV product variant only.

[i] NOTE If the Ethernet function is not used, the protective dust cap which is part of the delivery must be closed to protect the interface from water or dust ingress.

3.4.4. Antenna Ports

The antenna connectors are identified on the product with A1 to A3. QMA industrial standard connector is used.

A1 and A2 are used for LTE communication. Both antennas ports must be used and connected to external LTE antennas.

A3 is used for the included GNSS receiver. The antenna port must be connected to an external GNSS antenna.

[!] NOTICE Any unused antenna ports must be properly terminated with 50 Ohm, otherwise the product might be damaged when power is applied to a non-terminated antenna port.

[i] NOTE To ensure specified IP protection, suitable QMA connectors/cables and terminations must be used.

3.5. LED Indicators

Figure 9. LED indicators: Shows the location of the status LEDs on the front panel (DC, OPR, ERR, X1, X2).

LEDDescription
DCPower status
OPROperation status
ERRError status
X1Ethernet status for X1 port
X2Ethernet status for X2 port

[i] NOTE Refer to management guide for detailed LED status indication.

3.6. Dimensions

Dimensions are stated in mm and are regardless variants.

Figure 10. Dimensional drawing: Provides the physical dimensions of the router. Key dimensions include approximately 195.4 mm width, 83 mm height, and 53.5 mm depth.

4. Installation

4.1. Mounting

The product is fixed with the four fixing points located at the corners of the product. M5 or M6 screws are used for the fixation of the product. The screws are tightened with min. 3.0 Nm (fixing screw ISO 898/1, quality class 8.8).

[!] NOTICE All four specified fixing points must be used for fixing. The installation surface should be flat to have all fixing points connected to the surface.

[i] NOTE For indoor installation, consider additional protection against dust to ensure proper heat dissipation.

[i] NOTE For outdoor installation, consider additional protection against sun radiation, dust and dirt to optimize ambient temperature range.

[i] NOTE Unused connectors must be covered by a protective cap (delivered with the product), tightened to the specified torque in order to fulfill the specified ingress protection code.

4.2. Factory Reset

To reset the product into factory default settings, a reset adapter is needed which is plugged into one of the Ethernet ports X1 or X2 during startup.

Art. no.Description
3623-0799Factory Reset Plug, X-coded

Factory reset procedure

  1. Plug the factory reset adapter to one of the Ethernet interfaces.
  2. Power the product.
  3. Wait until factory reset adapter is detected. This is indicated by solid ORANGE OPR LED and RED ERR LED.
  4. Remove factory reset adapter within 15 seconds.
  5. Successful initiation of the factory reset is indicated by blinking ORANGE OPR LED and RED ERR LED.

4.3. Earth connection

For correct function, the earth connection at the grounding point needs to be properly connected to a solid ground. An M5 grounding screw at the housing is used for grounding. A short wire with a cross section of at least 4 mm² shall be used. The grounding wire is set below the rip-lock washer. The nut is fixed for good reliable grounding contact. The tightening torque of the nut shall be 2.0 Nm.

Figure 11. Earth connection: Shows the grounding point on the rear of the unit.

[!] NOTICE Do not use equipment without protective earth connection.

4.4. Connection of Cables

Recommended tightening torque for the M12 connectors is 0.6 Nm. All M12 connections are screw connections.

When connecting the power cable, ensure that the pins are connected correctly before tightening the power cable to the unit.

[i] NOTE This product has no replaceable fuse and should be connected via an external fuse for protection.

4.5. Cooling

This product uses convection cooling. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the product.

It is recommended to install the product in areas where the natural convection airflow is not blocked and that there is enough spacing around the product.

Figure 12. Installation with reduced natural convection airflow: Illustrates airflow obstruction.

Figure 13. Installation with natural convection airflow: Illustrates proper airflow.

When operating the product at high ambient temperatures, it is recommended to mount the product to a metallic base plate to improve the heat dissipation. The base plate increases the surface to spread the heat.

Figure 14. Improved heat transfer based on fixing plate and natural convection: Shows how a base plate aids heat dissipation.

[!] NOTICE Limited air flow is rising the product temperature and may lower the upper limit of the operating temperature range.

[!] NOTICE Temperature is dependent on the operational parameters, like RF output power, amount of traffic.

[!] NOTICE This product has integrated temperature sensors for monitoring the internal device temperatures. If temperature limits are exceeded, alarms are sent through the SW interface.

[!] NOTICE The operating conditions shall be ensured so that the normal operation does not cause temperature alarms. Improve installation conditions or RF parameters in case of any temperature alarms.

4.6. Replacement of Product

Disconnect all cables and unscrew the product from the wall. Mount the replacement product and reconnect all cables, observing the instructions in Connection of Cables. MTTR (Mean Time To Repair), i.e. time for replacement of product is: < 10 minutes.

[!] CAUTION - HOT SURFACE Be aware that the surface of this product may become hot. When it is operated at high temperatures, the external surface may exceed Touch Temperature Limit according to the product's relevant electrical safety standard. This product complies with Touch Temperature Limits throughout its operational temperature range.

5. Specifications

5.1. Interface Specifications

DC, Power port

Ibex-RT-330-LV:Ibex-RT-330-HV:
ConnectorM12 A-coded maleM12 A-coded male
Rated voltage24 VDC72 to 110 VDC
Operating voltage16 to 30 VDC50 to 138 VDC
Rated current0.6 A0.2 A
Rated frequencyDCDC
Inrush current39 mA²s at 24 VDC4 mA²s at 72 VDC
13 mA² at 110 VDC
Startup currentᵃ2 x nominal current2 x nominal current
PolarityReverse polarity protectedReverse polarity protected
Redundant power inputNoNo
Conductor cross section (flexible)> 0.5 mm² (AWG 20)> 0.5 mm² (AWG 20)
Cable temperature rating-40 to +70°C-40 to +70°C
Shielded cableNot requiredNot required

ᵃRecommended external supply current capability for proper startup

PoE (PoE powered product - Ibex-RT-330-LV only on X2)

ConnectorM12 X-coded female
Device modeA and B
Rated voltage48 VDC
Operating voltage37 to 57 VDC
Power classificationClass 3

Ethernet TX

ConnectorM12 X-coded female
Electrical specificationIEEE std 802.3
Data rate10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
DuplexFull or half, manual or auto
Transmission rangeUp to 100 m with CAT5e cable or better
CablingShielded cable CAT5e or better is recommended
Conductive chassisYes

[i] NOTE The product is to be connected to internal Ethernet networks without exiting a facility and being subjected to TNVs.

[!] NOTICE To avoid damages on the Ethernet interfaces, ensure that the far end side of the Ethernet cable shield itself is connected to protective earth.

SIM card

SIM typeMini-SIM 2FF
Temperature ratingIndustrial grade

Antenna LTE (A1 to A2)

ConnectorQMA
DirectionTransmit and receive
Cabling50 Ohm coaxial cable and LTE antenna required
Conductive chassisYes
Mobile interface2x2 MIMO LTE-A Cat 12, 3GPP E-UTRA Release 12
Mobile frequency bandsLTE-FDD: B1/B2/B3/B4/B5/B7/B8/B9/B12/B13/B14/B17/B18/B19/B20/B21/ B25 /B26/B28/B29/B30/B32/B66 (B29 and B32 support Rx only)
LTE-TDD: B38/B39/B40/B41
WCDMA: B1/B2/B3/B4/B5/B8/B9/B19
LTE-A carrier aggregationDL 2×CA / DL inter-band 2CA:
B1+B3/B5/B18/B19/B20/B21/B26;
B2+B4/B5/B12/B13/B14/B17/B29/B30/B66;
B3+B5/B7/B8/B19/B20/B28;
B4+B5/B12/B13/B17/B29/B30;
B5+B7/B25/B30/B66;
B7+B20/B28; B12+B25/B30;
B13+B66; B19+B21; B20+B32;
B25+B26/B41; B29+B30;
B39+B41; B66+B12/B29/B30/B5;
B14+B30/B66;
(B29 and B32 are for secondary component carrier only)

DL 2×CA / DL intra-band 2CA:
B2+B2; B3+B3; B4+B4; B7+B7; B25+B25; B38+B38; B39+B39; B40+B40;
B41+B41; B66+B66

DL 3×CA / DL inter-band 3CA:
B2+B4+B5; B2+B4+B13; B2+B5+B30; B2+B12+B30; B2+B29+B30;
B3+B7+B20; B3+B7+B28; B3+B7+B8; B4+B5+B30; B4+B12+B30;
B4+B29+B30; B5+B66+B2; B13+B66+B2; B66+B12+B30;
B66+B29+B30;
B66+B5+B30; B2+B14+B66

DL 3×CA / DL intra-band plus inter-band 3CA:
B3+B3+B7; B3+B7+B7; B3+B3+B20; B3+B3+B28; B3+B3+B1;
B4+B4+B5;
B4+B4+B13; B7+B7+B28; B5+B66+B66; B13+B66+B66; B66+B66+B2;
B39+B39+B41; B39+B41+B41; B14+B66+B66; B25+B25+B26;
B25+B41+B41

DL intra-band 3CA:
B40+B40+B40; B41+B41+B41;
B66+B66+B66;
Transmitting powerUL CA:B3C (operating temperature range limited to -25°C to +65°C)
Class 3 (23 dBm) for LTE-FDD bands
Class 3 (23 dBm) for LTE-TDD bands
Class 3 (24 dBm) for WCDMA

Antenna GNSS (A3)

ConnectorQMA
DirectionReceive
LNA supply voltageMax. 3.7 VDC (DC voltage for active antenna)
LNA supply currentMax. 70 mA (DC current for active antenna)
Cabling50 Ohm coaxial cable and GNSS antenna required
Conductive chassisYes
GNSS receiverGPS: L1C/A
SBAS: L1C/A
QZSS: L1C/A, L1 SAIF
GLONASS: L1OF
BeiDou: B1I
Galileo: E1B/C
Supported GNSS constellationsGPS
GPS+Galileo
GPS+Galileo+GLONASS
GPS+Galileo+BeiDou
GPS+GLONASS
GPS+BeiDou
Galileo
Galileo+GLONASS+BeiDou
Galileo+BeiDou
GLONASS
GLONASS+BeiDou
BeiDou
Sample rate≥ 10 Hz

[!] NOTICE Unused antenna port must be terminated with 50 Ohm terminations.

[!] NOTICE To avoid damages on the antenna interfaces, ensure that the far end side of the antenna cable and/or the antenna itself is connected to protective earth.

[i] NOTE External GNSS LNA is recommended to improve sensitivity.

5.2. Type Tests and Environmental Conditions

EMC and electrical conditions

Environmental phenomenaBasic standardDescriptionTest levels
ESDEN 61000-4-2EnclosureContact: ±6 kV
Air: ±8 kV
Fast transientsEN 61000-4-4DC power port
Ethernet ports
Antenna ports
± 2 kV, direct coupling
± 2 kV, capacitive coupling clamp
L-E: ± 1 kV, 12 Ω, 9 μF, 1.2/50 μs
L-E: ± 2 kV, 42 Ω, 0.5 μF, 1.2/50 μs
L-L: ± 1 kV, 12 Ω, 9 μF, 1.2/50 μs
L-L: ± 2 kV, 42 Ω, 0.5 μF, 1.2/50 μs
L-E: ± 1 kV, 2 Ω, 18 μF, 1.2/50 μs
SurgeEN 61000-4-5DC power port
Ethernet ports
Antenna ports
Power frequency magnetic fieldEN 61000-4-8Enclosure300 A/m continues, DC, 16.7 Hz, 50 Hz, 60 Hz
Pulsed magnetic fieldEN 61000-4-9Enclosure300 A/m
Radiated RF immunityEN 61000-4-3Enclosure20 V/m, 80% AM (1kHz) at 80 MHz to 6 GHz
30 V/m, PM 200 Hz square at 380 MHz to 385 MHz
30 V/m, PM 200 Hz square at 390 MHz to 395 MHz
3 V/m, PM 200 Hz square at 104, 136, 165, 200, 260, 330, 430, 560, 715 ±1, 920 ±1 MHz
Conducted RF immunityEN 61000-4-6DC power port
Ethernet ports
Antenna ports
10 V, 80% AM (1 kHz) from 0.15 to 80 MHz
Radiated RF emissionCISPR 16-2-3EnclosureClass B
FCC Part 15 B, Class B
Conducted RF emissionCISPR 16-2-1DC power port
Ethernet ports
Ibex-RT-330-LV: Class B
Ibex-RT-330-HV: Class A
Insulation resistanceEN 50155Power port (DC) to all other ports> 100 MOhm
Dielectric strengthEN 50155Power port (DC) to all other portsIbex-RT-330-LV: 750 VDC, 60 s
Ibex-RT-330-HV: 2250 VDC, 60 s

Environmental and mechanical conditions

Environmental phenomenaBasic standardDescriptionTest levels
TemperaturesEN 60068-2-1
EN 60068-2-2
EN 60068-2-14
Operational
Storage and transport
-40 to +70°C (-40 to +158°F)ᵃ
-55 to +85°C (-67 to +185°F)
HumidityEN 60068-2-30Operational
Storage and transport
5-95% relative humidity
AltitudeOperational2000 m
MTBFIEC TR 62380360,000 hours
VibrationMIL STD 810, M514.7 (sine)Operational5 to 10 Hz, 7.62 mm p-p
10 to 200 Hz, 1.5 g
20 sweep cycles in each axis, 0.9 octave/min
EN 60068-2-64 (random)Operational, endurance test11.44 m/s² random, 5 to 150 Hz, 3 x 5 h
ShockᵇEN 60068-2-27
MIL STD 810, M516.7
Operational100 m/s², 30 ms, 3 x 6 shocks (half sine)
10 g, 11 ms, 3 x 6 shocks (saw tooth)
Weight1540 gr
Degree of protectionEN 60529EnclosureIP66ᶜ
CoolingConvection
Pollution degreeEN 62368-1PD2
Conformal coating typeIPC-A-610Electronic modulesAR (Acrylic)

ᵃRefer to "Safety and Regulations" chapter regarding touch temperature

ᵇThe power and Ethernet cables need to be fastened 200 mm or closer to the unit. The same recommendation applies to the Antenna cables.

ᶜProvided all connectors are connected with IP66 cabling or fitted with protective caps (delivered with the unit) and tightened to the specified torque

6. Abbreviations and Terms

AbbreviationDescription
AMAmplitude Modulation
AREMAAmerican Railway Engineering and Maintenance-of-Way Association
AWGAmerican Wire Gauge
BPSKBinary Phase Shift Keying
CAT5eCategory 5 Enhanced Cable
CEConformité Européenne
CPUCentral Processing Unit
DCDirect Current
EMCElectromagnetic Compatibility
ENEuropean Standard
ERRError
ESDElectro Static Discharge
ETSIEuropean Telecommunications Standards Institute
FCCFederal Communication Commission
FLOSSFree/Libre Open Source Software
HVHigh Voltage
IECInternational Engineering Consortium
ICIndustry Canada
IDIdentification
I/OInput / Output
IPIngress Protection
ISOInternational Standardization Organisation
LANLocal Area Network
LEDLight Emitting Diode
LVLow Voltage
MIMOMultiple Input, Multiple Output
MTBFMean Time between Failure
MTTRMean Time to Repair
OPROperation
PMPulse Modulated
PoEPower over Ethernet
QMAQuick-connect RF Connectors
QRQuick Response
RFRadio Frequency
TNVTelephone Network Voltage
SNSerial Number
SNMPSimple Network Management Protocol
WebGUIWeb Graphical User Interface
WeConfigWestermo Configuration Tool
WEEEWaste Electrical and Electronics Equipment
WLANWireless Local Area Network

7. Revision Notes

RevisionDateChange description
Rev. D2021-10(User guide migrated to CMS tool), 2.2 Safety Information; information on cooling moved to chapter 4.5 Cooling, 2.5.1 Agency Approvals and Standards Compliance updated, 3.3.2 Front Side Label; callouts reversed order, 3.5 Led Indicatiors; illustration added, 4.2 Factory Reset moved from old chapter 3.6, 4,5 Cooling; illustrations updated.
Rev. C2021-062.5.5 Europe - Simplified Declaration of Conformity updated text and figure,
Rev. B2020-10Updated frontpage
Rev. A2020-06First revision

Westermo. Metallverksgatan 6, SE-721 30 Västerås, Sweden

Tel +46 16 42 80 00 Fax +46 16 42 80 01

E-mail: info@westermo.com

www.westermo.com

Document Number: 6623-22901 REV. D, Date: 2021 10, Manufacturer: Westermo Network Technologies AB, Sweden

Models: Ibex-RT-330 Series, LTE Router, Ibex-RT-330 Series LTE Router

File Info : application/pdf, 34 Pages, 4.08MB

PDF preview unavailable. Download the PDF instead.

westermo ug 6623-22901 ibex-rt-330 revd AH XSL Formatter V6.6 R1 for Linux64 : 6.6.1.34539 (2018/08/29 13:12JST) Antenna House PDF Output Library 6.6.1307 (Linux64)

Related Documents

PreviewIbexOS Management Guide - Westermo
Comprehensive guide to Westermo's IbexOS firmware, detailing features, configuration, and management for industrial wireless communication devices like Ibex-RT series.
PreviewWestermo Ibex-RT-330-5G: 5G EN 50155 Railway Router
Westermo Ibex-RT-330-5G is a high-performance 5G mobile router designed for onboard railway applications. It supports 3GPP Release 16, 5G NSA/SA, and features a 5G sub 6 GHz MIMO 4x4 interface, dual SIM support, and compliance with EN 50155 and EN 45545-2 standards. The router offers advanced firewall capabilities, high-performance VPN connectivity, and a wide operating temperature range.
PreviewWestermo Ibex-RT-330-5G: EN 50155 5G Router for Railway Applications
Westermo Ibex-RT-330-5G is a ruggedized mobile 5G router designed for onboard use in trains, trams, and other vehicles. It supports 3GPP Release 16 (5G NSA/SA), features a 5G sub 6 GHz 4x4 MIMO interface, and operates within a wide temperature range (-40°C to +70°C) and IP66 ingress protection. The router is EN 50155 and EN 45545-2 certified, offering high bandwidth, advanced firewall, and VPN connectivity for demanding railway applications.
PreviewWestermo Ibex-RT-330-5G: Rugged 5G Router for Railway Applications
Westermo Ibex-RT-330-5G is a robust 5G mobile router designed for onboard use in trains, trams, locomotives, mining vehicles, and buses. It offers high performance and reliable internet connectivity, supporting 3GPP Release 16 for 5G NSA/SA and LTE. Key features include EN 50155 and EN 45545-2 compliance, IP66 rating, wide operating temperature range (-40°C to +70°C), and advanced firewall and VPN capabilities.
PreviewWestermo Ibex-RT-630-5G: 5G and WLAN Router for Mobile Applications
The Westermo Ibex-RT-630-5G is a robust 5G mobile router designed for demanding onboard applications in trains, trams, locomotives, mining vehicles, and buses. It offers high-performance connectivity, advanced security features, and compliance with railway industry standards.
PreviewWestermo Ibex-1510 Series EN 50155 Wi-Fi 6 Access Point Datasheet
Datasheet for the Westermo Ibex-1510 series, a rugged EN 50155 certified Wi-Fi 6 access point designed for demanding railway and onboard applications. Features dual-band 802.11ax, M12 connectors, and wide operating temperature range.
PreviewWestermo Ibex-3510 Series EN 50155 Wi-Fi 6E Access Point
Westermo Ibex-3510 is a reliable, compact, and secure triple-band Wi-Fi 6E Access Point/Client designed for demanding railway and transportation environments. It supports simultaneous 2.4 GHz, 5 GHz, and 6 GHz bands with high-speed data transfer and advanced cybersecurity features.
PreviewWestermo Ibex-1510 EN 50155 Wi-Fi 6 Access Point - Technical Specifications
Detailed technical specifications for the Westermo Ibex-1510, an EN 50155 compliant Wi-Fi 6 access point designed for demanding railway applications. Features include dual-band Wi-Fi 6, high reliability, compact design, and robust environmental protection.