140319026SZN-002

jenner.liu

Test Report

Hisense Electric Co., Ltd. LCDD0041 LED LCD TV W9HLCDD0041 W9HLCDD0041 lcdd0041

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=2244051
Hisense Electric Co., Ltd.
Application For
Certification FCC ID: W9HLCDD0041
LED LCD TV
Model: LTDN40D36US Additional Model: 40D36, 40H3C, LTDN40D37US, 40D37, 40H3E
Computer Peripheral
Report No.: 140319026SZN-002

Prepared and Checked by:
Sign on file Jenner Liu Assistant Engineer

Approved by:
Digitally signed
by Billy Li
Location:
Intertek Testing
Services
Billy Li Supervisor Date: April 09, 2014

·

The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample

may be said to have been obtained.

·

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability

are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for

any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report. Any use of the Intertek name or

one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test

results referenced from this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever

been under an Intertek certification program.

·

For Terms And Conditions of the services, it can be provided upon request.

·

The evaluation data of the report will be kept for 3 years from the date of issuance.

TRF No.: FCC 15C_PC_b

Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Website: www.china.intertek-etlsemko.com

INTERTEK TESTING SERVICES

LIST OF EXHIBITS

INTRODUCTION EXHIBIT 1: EXHIBIT 2: EXHIBIT 3: EXHIBIT 4: EXHIBIT 5: EXHIBIT 6: EXHIBIT 7: EXHIBIT 8: EXHIBIT 9:

General Description System Test Configuration Emission Results Equipment Photographs Product Labeling Technical Specifications Instruction Manual Miscellaneous Information Test Equipment List

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
i

INTERTEK TESTING SERVICES

MEASUREMENT / TECHNICAL REPORT
Hisense Electric Co., Ltd. MODEL: LTDN40D36US Additional Model: 40D36, 40H3C, LTDN40D37US, 40D37, 40H3E
FCC ID: W9HLCDD0041

This report concerns (check one:)

Original Grant X

Equipment Type: JBP-Class B Computing Device Peripheral

Class II Change

Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?

Yes

No X

If yes, defer until: date

Company Name agrees to notify the Commission by: date
of the intended date of announcement of the product so that the grant can be issued on that date.

Transition Rules Request per 15.37?

Yes

No X

If no, assumed Part 15, Subpart B for unintentional radiator - the new 47 CFR [10-01-13 Edition] provision.

Report prepared by:

Jenner Liu Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road Nanshan District, Shenzhen, P. R. China Phone: (86 755) 8614 0639 Fax: (86 755) 8601 6751

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
ii

INTERTEK TESTING SERVICES
Table of Contents
1.0 General Description.............................................................................................. 2 1.1 Product Description........................................................................................ 2 1.2 Related Submittal(s) Grants........................................................................... 2 1.3 Test Methodology........................................................................................... 3 1.4 Test Facility.................................................................................................... 3
2.0 System Test Configuration .................................................................................. 5 2.1 Justification .................................................................................................... 5 2.2 EUT Exercising Software ............................................................................... 5 2.3 Special Accessories ....................................................................................... 5 2.4 Equipment Modification.................................................................................. 5 2.5 Measurement Uncertainty .............................................................................. 6 2.6 Support Equipment List and Description ........................................................ 6
3.0 Emission Results.................................................................................................. 8 3.1 Field Strength Calculation .............................................................................. 9 3.2 Radiated Emission Configuration Photograph ............................................. 11 3.3 Radiated Emission Data............................................................................... 12 3.4 Conducted Emission at Mains Terminal ........................................................ 15 3.5 Conducted Emission Configuration Photograph .......................................... 15 3.6 Conducted Emission .................................................................................... 15
4.0 Equipment Photographs .................................................................................... 22 5.0 Product Labelling ............................................................................................... 24 6.0 Technical Specifications .................................................................................... 26 7.0 Instruction Manual.............................................................................................. 28 8.0 Miscellaneous Information ................................................................................ 30 9.0 Test Equipment List ........................................................................................... 34
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
iii

INTERTEK TESTING SERVICES

List of attached file

Exhibit Type Test Report Test Setup Photo Test Setup Photo External Photo Internal Photo Block Diagram ID Label / Location User Manual Cover Letter Cover Letter

File Description Test Report Radiated photos Conducted photos External Photos Internal Photos Block Diagram Label Artwork and Location User Manual Confidential Letter Letter of Agency

Filename report.pdf radiated photos.pdf conducted photos.pdf external photos.pdf internal photos.pdf block.pdf label.pdf manual.pdf request.pdf agency.pdf

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
iv

INTERTEK TESTING SERVICES EXHIBIT 1
GENERAL DESCRIPTION
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
1

INTERTEK TESTING SERVICES
1.0 General Description 1.1 Product Description
The Equipment Under Test (EUT) is a LED LCD TV. The device can be used to connect PC by HDMI and VGA ports. The EUT is powered by 120V/60Hz. The Models: 40D36, 40H3C, LTDN40D37US, 40D37, 40H3E are the same as the Model: LTDN40D36US in hardware aspect. The difference in front plastic cabinet and model number serves as marketing strategy. 1.2 Related Submittal(s) Grants This is an application for certification of a computer peripheral. Other digital functions were reported in the verification report: 140319026SZN-001.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
2

INTERTEK TESTING SERVICES
1.3 Test Methodology Both AC mains line-conducted and radiated emission measurements were performed according to the procedures in ANSI C63.4 (2009). Radiated emission measurement was performed in Semi-anechoic chamber and conducted emission measurement was performed in shield room. For radiated emission measurement, preliminary scans were performed in the semianechoic chamber only to determine the worst case modes. All radiated tests were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the "Justification Section" of this Application.
1.4 Test Facility The Semi-anechoic chamber and shielding room used to collect the radiated data and conducted data are Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch and located at 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China. This test facility and site measurement data have been fully placed on file with the FCC (Registration Number: 242492).
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
3

INTERTEK TESTING SERVICES EXHIBIT 2
SYSTEM TEST CONFIGURATION
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
4

INTERTEK TESTING SERVICES
2.0 System Test Configuration
2.1 Justification
The system was configured for testing in a typical fashion (as a customer would normally use it), and in the confines as outlined in ANSI C63.4 (2009).
The device was powered by AC 120V/60Hz during the test. The worst case data was reported in this report.
For maximizing emissions, the EUT was rotated through 360°, the antenna height was varied from 1 meter to 4 meters above the ground plane, and the antenna polarization was changed. The step by step procedure for maximizing emissions led to the data reported in Exhibit 3.0.
The rear of unit shall be flushed with the rear of the table.
The equipment under test (EUT) was configured for testing in a typical fashion (as a customer would normally use it). The EUT was placed on turntable, which enabled the engineer to maximize emissions through its placement in the three orthogonal axes.
The frequency range from 30MHz to 2GHz was searched for spurious emissions from the device. Only those emissions reported were detected. All other emissions were at least 20 dB below the applicable limits.
2.2 EUT Exercising Software
N/A
2.3 Special Accessories
N/A
2.4 Equipment Modification
Any modifications installed previous to testing by Hisense Electric Co., Ltd. will be incorporated in each production model sold / leased in the United States.
No modifications were installed by Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
5

INTERTEK TESTING SERVICES

2.5 Measurement Uncertainty
When determining the test conclusion, the Measurement Uncertainty of test has been considered.

2.6 Support Equipment List and Description This product was tested in the following configuration: Refer List:

Description Laptop Laptop
Hard Disk USB Memory 1394 Cable USB Cable Dummy Load VGA Cable HDMI Cable*3 PC Audio Cable
AV Cable YPbPr Cable Digital Audio Out Cable Tuner Resister Headphone Remote controller

Manufacturer Lenovo Lenovo
Smart.drive SanDisk
Smart.drive Smart.drive
N/A HP N/A N/A N/A N/A N/A N/A N/A Hisense

Model No. T420 X1
HD-003 SDCZ36-002G-P36 Unshielded, Length 180cm Unshielded, Length 155cm
N/A Unshielded, Length 180cm UnShielded, Length 180cm Unshielded, Length 150cm Unshielded, Length 120cm Unshielded, Length 120cm Unshielded, Length 120cm
75ohm Unshielded, Length 110cm
N/A

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
6

INTERTEK TESTING SERVICES EXHIBIT 3
EMISSION RESULTS
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
7

INTERTEK TESTING SERVICES
3.0 Emission Results Data is included worst case configuration (the configuration which resulted in the highest emission levels). A sample calculation, configuration photographs and data tables of the emissions are included.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
8

INTERTEK TESTING SERVICES
3.1 Field Strength Calculation The field strength is calculated by adding the reading on the Spectrum Analyzer to the factors associated with preamplifiers (if any), antennas, cables, pulse desensitization and average factors (when specified limit is in average and measurements are made with peak detectors). A sample calculation is included below. FS = RA + AF + CF - AG + PD + AV where FS = Field Strength in dBµV/m RA = Receiver Amplitude (including preamplifier) in dBµV CF = Cable Attenuation Factor in dB AF = Antenna Factor in dB/m AG = Amplifier Gain in dB PD = Pulse Desensitization in dB AV = Average Factor in -dB In the radiated emission table which follows, the reading shown on the data table may reflect the preamplifier gain. An example of the calculations, where the reading does not reflect the preamplifier gain, follows: FS = RA + AF + CF - AG + PD + AV
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
9

INTERTEK TESTING SERVICES
3.1 Field Strength Calculation (cont'd) Example Assume a receiver reading of 62.0dBµV is obtained. The antenna factor of 7.4dB/m and cable factor of 1.6dB is added. The amplifier gain of 29dB is subtracted. The pulse desensitization factor of the spectrum analyzer was 0dB, and the resultant average factor was -10dB. The net field strength for comparison to the appropriate emission limit is 32dBµV/m. This value in dBµV/m was converted to its corresponding level in µV/m. RA = 62.0dBµV AF = 7.4dB/m CF = 1.6dB AG = 29.0dB PD = 0dB AV = -10dB FS = 62 + 7.4 + 1.6 - 29 + 0 + (-10) = 32dBµV/m Level in µV/m = Common Antilogarithm [(32dBµV/m)/20] = 39.8µV/m
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
10

INTERTEK TESTING SERVICES
3.2 Radiated Emission Configuration Photograph Worst Case Radiated Emission At 222.741MHz (HDMI In Mode)
For electronic filing, the worst case radiated emission configuration photograph is saved with filename: radiated photos.pdf.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
11

INTERTEK TESTING SERVICES
3.3 Radiated Emission Data The data on the following page lists the significant emission frequencies, the limit and the margin of compliance. Numbers with a minus sign are below the limit. Judgement: Passed by 3.7dB margin (HDMI In Mode)
TEST PERSONNEL: Sign on file Jenner Liu Assistant Engineer Typed/Printed Name April 09, 2014 Date
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
12

INTERTEK TESTING SERVICES
Company: Hisense Electric Co., Ltd. Date of Test: April 09, 2014 Model: LTDN40D36US Operating Mode: HDMI In

Polarization
Horizontal Horizontal Horizontal Horizontal
Vertical Vertical Vertical Vertical

Frequency (MHz)
138.640 222.741 672.128 1190.000 37.554 65.880 140.560 1336.000

Radiated Emissions

Reading Pre- Antenna Net

Limit

(dBµV) Amp Factor at 3m at 3m

Gain

(dB) (dBµV/m) (dBµV/m)

(dB)

42.6

20.0

8.0

30.6

43.5

52.1

20.0 10.2

42.3

46.0

38.5

20.0 20.0

38.5

46.0

38.4

20.0 24.7

43.1

54.0

41.0

20.0 13.1

34.1

40.0

43.2

20.0

5.1

28.3

40.0

40.4

20.0

8.2

28.6

43.5

34.0

20.0

26.2

40.2

54.0

Margin (dB)
-12.9 -3.7 -7.5 -10.9 -5.9 -11.7 -14.9 -13.8

NOTES: 1. Quasi-Peak detector is used for frequency up to 1GHz and Peak detector is used for frequency from 1-2GHz.

2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3 meter distances were measured at 0.3- meter and an inverse proportional extrapolation was performed to compare the signal level to the 3 meter limit. No other harmonic emissions than those reported were detected at a test distance of 0.3-meter.

3. Negative value in the margin column shows emission below limit.

4. All emissions up to 1GHz are below the QP limit and all emissions between 1-2GHz are below the AV limit.

Test Engineer: Jenner Liu

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
13

INTERTEK TESTING SERVICES
Company: Hisense Electric Co., Ltd. Date of Test: April 09, 2014 Model: LTDN40D36US Operating Mode: VGA

Polarization
Horizontal Horizontal Horizontal Horizontal Horizontal
Vertical Vertical Vertical Vertical

Frequency (MHz)
178.186 193.043 267.306 415.781 1345.000 66.115 103.954 774.054 1371.250

Radiated Emissions

Reading Pre- Antenna Net

(dBµV) Amp Factor at 3m

Gain

(dB) (dBµV/m)

(dB)

47.2

20.0

10.0

37.2

49.0

20.0

10.4

39.4

45.8

20.0

14.1

39.9

37.1

20.0

17.7

39.6

21.3

20.0

26.2

34.8

51.9

20.0

5.1

27.5

46.3

20.0

8.2

37.0

33.9

20.0

20.6

34.5

21.5

20.0

29.7

31.2

Limit at 3m (dBµV/m)
43.5 43.5 46.0 46.0 54.0 40.0 43.5 46.0 54.0

Margin (dB)
-6.3 -4.1 -6.1 -6.4 -19.2 -12.5 -6.5 -11.5 -22.8

NOTES: 1. Quasi-Peak detector is used for frequency up to 1GHz and PEAK detector is used for frequency from 1-2GHz.
2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3 meter distances were measured at 0.3- meter and an inverse proportional extrapolation was performed to compare the signal level to the 3 meter limit. No other harmonic emissions than those reported were detected at a test distance of 0.3-meter.

3. Negative value in the margin column shows emission below limit.
4. All emissions up to 1GHz are below the QP limit and all emissions between 1-2GHz are below the AV limit.

Test Engineer: Jenner Liu

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
14

INTERTEK TESTING SERVICES
3.4 Conducted Emission at Mains Terminal 3.5 Conducted Emission Configuration Photograph
Worst Case Conducted Configuration at
0.411 MHz(VGA Mode) For electronic filing, the worst case conducted emission configuration photograph is saved with filename: conducted photos.pdf.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
15

INTERTEK TESTING SERVICES
3.6 Conducted Emission Data Judgement: Passed by 4.3 dB margin (VGA Mode)
TEST PERSONNEL: Sign on file Jenner Liu Assistant Engineer Typed/Printed Name April 09, 2014 Date
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
16

INTERTEK TESTING SERVICES
Company: Hisense Electric Co., Ltd. Date of Test: April 09, 2014 Model: LTDN40D36US Operating Mode: VGA Phase: Live Conducted Emission Test - FCC

80

70

60

FCC Part 15 Class B Voltage on Mains QP

50

FCC Part 15 Class B Voltage on Mains AV

Level in dBµ

40

30

20

10

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Result Table QP

Frequency (MHz)
0.150 0.198 0.258 0.338 0.410 0.470

QuasiPeak Line

(dBV)

46.6

L1

49.2

L1

49.7

L1

44.8

L1

44.4

L1

42.5

L1

Corr. (dB)
9.8 9.7 9.7 9.7 9.7 9.7

Margin (dB)
19.4 14.5 11.8 14.5 13.2 14.0

Limit (dBV)
66.0 63.7 61.5 59.3 57.6 56.5

Result Table AV

Frequency Average Line

(MHz)

(dBV)

0.150

25.1

L1

0.198

39.9

L1

0.258

37.7

L1

0.338

29.6

L1

0.410

42.9

L1

0.470

35.7

L1

Corr. (dB)
9.8 9.7 9.7 9.7 9.7 9.7

Margin (dB)
30.9 13.8 13.8 19.7 4.7 10.8

Limit (dBV)
56.0 53.7 51.5 49.3 47.6 46.5

Test Engineer: Jenner Liu

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
17

INTERTEK TESTING SERVICES
Company: Hisense Electric Co., Ltd. Date of Test: April 09, 2014 Model: LTDN40D36US Operating Mode: VGA Phase: Neutral Conducted Emission Test - FCC

80

70

60

FCC Part 15 Class B Voltage on Mains QP

50

FCC Part 15 Class B Voltage on Mains AV

Level in dBµ

40

30

20

10

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Result Table QP

Frequency (MHz)
0.150 0.195 0.249 0.318 0.411 0.470

QuasiPeak Line

(dBV)

47.9

N

49.4

N

49.9

N

45.5

N

44.4

N

45.2

N

Corr. (dB)
10.2 10.2 10.2 10.2 10.2 10.2

Margin (dB)
18.1 14.4 11.9 14.3 13.2 11.3

Limit (dBV)
66.0 63.8 61.8 59.8 57.6 56.5

Result Table AV

Frequency Average Line

(MHz)

(dBV)

0.150

23.8

N

0.195

40.1

N

0.249

37.2

N

0.318

32.0

N

0.411

43.3

N

0.470

37.7

N

Corr. (dB)
10.2 10.2 10.2 10.2 10.2 10.2

Margin (dB)
32.2 13.7 14.6 17.8 4.3 8.8

Limit (dBV)
56.0 53.8 51.8 49.8 47.6 46.5

Test Engineer: Jenner Liu

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
18

INTERTEK TESTING SERVICES
Company: Hisense Electric Co., Ltd. Date of Test: April 09, 2014 Model: LTDN40D36US Operating Mode: HDMI In Phase: Live Conducted Emission Test - FCC

Level in dBµ

80 70 60 50 40 30 20 10
0 150k

FCC Part 15 Class B Voltage on Mains QP FCC Part 15 Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Result Table QP

Frequency (MHz)
0.150 0.186 0.202 0.246 0.470 1.426

QuasiPeak Line

(dBV)

48.5

L1

47.1

L1

46.6

L1

44.1

L1

41.8

L1

32.5

L1

Corr. (dB)
9.8 9.7 9.7 9.7 9.7 9.8

Margin (dB)
17.5 17.1 16.9 17.8 14.7 23.5

Limit (dBV)
66.0 64.2 63.5 61.9 56.5 56.0

Result Table AV

Frequency (MHz)

Average (dBV)

Line

0.150

20.1

L1

0.186

32.0

L1

0.202

29.3

L1

0.246

28.6

L1

0.470

34.9

L1

1.426

26.4

L1

Corr. (dB) 9.8 9.7 9.7 9.7 9.7 9.8

Margin (dB) 35.9 22.2 24.2 23.3 11.6 19.6

Limit (dBV)
56.0 54.2 53.5 51.9 46.5 46.0

Test Engineer: Jenner Liu

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
19

INTERTEK TESTING SERVICES
Company: Hisense Electric Co., Ltd. Date of Test: April 09, 2014 Model: LTDN40D36US Operating Mode: HDMI In Phase: Neutral Conducted Emission Test - FCC

Level in dBµ

80 70 60 50 40 30 20 10
0 150k

FCC Part 15 Class B Voltage on Mains QP FCC Part 15 Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Result Table QP

Frequency (MHz)
0.154 0.186 0.246 0.470 0.950 1.426

QuasiPeak Line

(dBV)

45.9

N

48.9

N

45.6

N

44.2

N

38.0

N

35.7

N

Corr. (dB)
10.2 10.2 10.2 10.2 10.3 10.4

Margin (dB)
19.9 15.3 16.3 12.3 18.0 20.3

Limit (dBV)
65.8 64.2 61.9 56.5 56.0 56.0

Result Table AV

Frequency Average Line

(MHz)

(dBV)

0.154

20.4

N

0.186

35.8

N

0.246

31.8

N

0.470

37.3

N

0.950

28.9

N

1.426

27.7

N

Corr. (dB)
10.2 10.2 10.2 10.2 10.3 10.4

Margin (dB)
35.4 18.4 20.1 9.2 17.1 18.3

Limit (dBV)
55.8 54.2 51.9 46.5 46.0 46.0

Test Engineer: Jenner Liu

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
20

INTERTEK TESTING SERVICES EXHIBIT 4
EQUIPMENT PHOTOGRAPHS
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
21

INTERTEK TESTING SERVICES
4.0 Equipment Photographs For electronic filing, photographs of the tested EUT are saved with filename: external photos.pdf and internal photos.pdf.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
22

INTERTEK TESTING SERVICES EXHIBIT 5
PRODUCT LABELLING
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
23

INTERTEK TESTING SERVICES
5.0 Product Labelling For electronics filing, the FCC ID label artwork and the label location are saved with filename: label.pdf.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
24

INTERTEK TESTING SERVICES EXHIBIT 6
TECHNICAL SPECIFICATIONS
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
25

INTERTEK TESTING SERVICES
6.0 Technical Specifications For electronic filing, the block diagram of the tested EUT is saved with filename: block.pdf.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
26

INTERTEK TESTING SERVICES EXHIBIT 7
INSTRUCTION MANUAL
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
27

INTERTEK TESTING SERVICES
7.0 Instruction Manual For electronic filing, a preliminary copy of the Instruction Manual is saved with filename: manual.pdf. This manual will be provided to the end-user with each unit sold / leased in the United States.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
28

INTERTEK TESTING SERVICES EXHIBIT 8
MISCELLANEOUS INFORMATION
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
29

INTERTEK TESTING SERVICES
8.0 Miscellaneous Information This miscellaneous information includes emission measuring procedure.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
30

INTERTEK TESTING SERVICES
8.1 Emissions Test Procedures The following is a description of the test procedure used by Intertek Testing Services in the measurements of computer peripheral operating under Part 15, Subpart B rules. The test set-up and procedures described below are designed to meet the requirements of ANSI C63.4 - 2009. The computer peripheral equipment under test (EUT) is placed on a wooden turntable which is four feet in diameter and approximately one meter in height above the ground plane. During the radiated emissions test, the turntable is rotated and any cables leaving the EUT are manipulated to find the configuration resulting in maximum emissions. The antenna height and polarization are varied during the testing to search for maximum signal levels. The height of the antenna is varied from one to four meters. Detector function for radiated emissions are in QP mode from the frequency band 30MHz to 1GHz with RBW setting 120kHz and in PK & AV mode from frequency band 1GHz to 2GHz with RBW setting 1MHz. Detector function for conducted emissions are in QP & AV mode and IFBW setting is 9kHz from the frequency band 150kHz to 30MHz. For radiated emission, the frequency range scanned is 30MHz to 2GHz. For line-conducted emissions, the range scanned is 150kHz to 30MHz.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
31

INTERTEK TESTING SERVICES
8.1 Emissions Test Procedures (cont'd) The EUT is warmed up for 15 minutes prior to the test. Conducted measurements are made as described in ANSI C63.4 - 2009.
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
32

INTERTEK TESTING SERVICES EXHIBIT 9
TEST EQUIPMENT LIST
TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
33

INTERTEK TESTING SERVICES
9.0 Test Equipment List

Equipment No.
SZ061-03 SZ185-01 SZ188-01 SZ062-04 SZ185-02 SZ187-01 SZ187-02 SZ188-03

Equipment
Biconilog Antenna
EMI Receiver Anechoic Chamber
RF Cable
EMI Test Receiver Two-Line VNetwork Two-Line VNetwork Shielding
Room

Manufacturer ETS R & S ETS
RADIALL R&S R&S R&S ETS

Model No.
3142C

Serial No.
00066460

Cal. Date 29-Jun-13

Due Date 29-Jun-2014

ESCI RFD-F/A-
100 RG 213U
ESCI

100547 02 Mar 2013
--
100692

10-Mar-2014 10-Mar-2015 02-Mar-2013 02-Mar-2015 08-Jan-2014 08-Jul-2014 09-Nov-2013 09-Nov-2014

ENV216 100072 09-Nov-2013 09-Nov-2014

ENV216 100073 09-Nov-2013 09-Nov-2014

RFD-100 4100 23-Aug-2013 23-Aug-2014

TRF No.: FCC 15C_PC_b FCC ID: W9HLCDD0041
34


GPL Ghostscript 9.0