Functional Devices, Inc. Building Automation & Lighting Controls
Catalog Request - Functional Devices, Inc.
RELAYS | CURRENT SENSORS | POWER SUPPLIES | TRANSFORMERS | POWER MONITORING | WIRELESS DEVICES POWER CONTROL | SPECIALTY PERIPHERAL CONTROLS | ACCESSORIES | ENCLOSURES | INTELLIGENT FIELD DEVICES NEW & FEATURED PRODUCTS RELAYS 10-15 AMP: 19 | 20-30 AMP: 45 | LATCHING: 64 | LOW INPUT / OPTOISOLATED: 67 POLARIZED / ALARM: 74 | DRY CONTACT INPUT: 78 CURRENT SENSORS SOLID & SPLIT CORE: 87 | TRANSDUCERS: 90 | T STYLE: 95 ENCLOSED & TRACK MOUNT RELAY AND SENSOR COMBINATIONS: 97 POWER SUPPLIES 40-100 VA AC: 109 | 200-500 VA AC: 113 | AC POWER SUPPLY KITS: 120 | DC: 122 TRANSFORMERS U.S. MANUFACTURED: 127 | 20-375 VA: 129 SPECIALTY PERIPHERAL CONTROLS FAN SAFETY ALARM CIRCUITS / GENERAL PURPOSE LOGIC BOARDS: 132 I/O EXPANDERS: 139 | MANUAL ANALOG OVERRIDE SWITCH: 141 INTELLIGENT FIELD DEVICES BACNET® : 144 | MODBUS : 156 POWER MONITORING POWER METERS: 160 | CURRENT TRANSFORMERS: 163 POWER CONTROL POWER CONTROL CENTERS: 166 | TRACK MOUNT CIRCUIT BREAKER SWITCHES: 166 PREPACKAGED SWITCHES: 167 | UPS POWER SUPPLY KITS: 169 WIRELESS DEVICES WIRELESS RELAY TRANSCEIVERS & RECEIVERS : 177 | WIRELESS PHASE ANGLE DIMMER : 179 WIRELESS TRANSMITTERS: 180 | WIRELESS VACANCY / OCCUPANCY SENSORS: 181 ENCLOSURES PLASTIC: 185 | METAL: 185 ACCESSORIES SUB-PANELS: 192 | MOUNTING SUPPLIES: 196 | REPLACEMENT PARTS: 198 INDEX & HOUSING GUIDE HOUSING GUIDE: 201 | INDEX: 202 4 19 84 106 127 131 142 159 164 175 183 190 201 NEW & FEATURED Functional Devices was incorporated on July 28, 1969 by Albert Rittmann, an engineer with a love for tinkering with electronics. The factory opened in September 1969 in Russiaville, Indiana. Our first day at a second building, now the Company Headquarters, was in September of 2012 when shipping and power supplies manufacturing moved into the facility in Sharpsville, Indiana. Our office and administrative employees transitioned in November 2014. We finalized our move with all production employees and production support moving in December 2015. 2 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NEW & FEATURED Functional Devices was inducted into the 2022 Manufacturers Hall of Fame by the Indiana Manufacturers Association for recognizing our commitment to the Indiana manufacturing community! Functional Devices Appoints CEO Functional Devices was pleased to announce the promotion of Mark Fernandes to Chief Executive Officer in 2022. Mark Fernandes joined the Company in 2003 as an engineer. During his tenure at the Company, he has held numerous leadership positions, including Engineering Manager and Vice President of Manufacturing and Engineering. In 2014, Mark assumed the role of President and has overseen several strategic initiatives that have increased productivity, shortened time to market for new products, and maintained Functional Devices' reputation as the leader in product quality. Named One of Best Places to Work in Manufacturing We were proud to be recognized on the list of 2022 Best Places to Work in Manufacturing, along with 12 other Indiana manufacturers. This inaugural program was initiated by the Indiana Chamber of Commerce for companies that stand out within the manufacturing industry for creating an outstanding workplace for their employees. Functional Devices CEO, Mark Fernandes, was appointed to the Continental Automated Buildings Association (CABA) Board of Directors, an international not-for-profit industry association dedicated to the advancement of connected home and intelligent building technologies. (800) 888-5538 | www.functionaldevices.com 3 NEW & FEATURED BUILD THE BEST FOUNDATION WITH THE RIB® TRIFECTA 4 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NEW & FEATURED RELAYS · Prepackaged: LED indicator, pre-wired, transient protection, and optional HOA switch · 10-30 Amp contact ratings · Coil voltages of 10-30 Vac/dc, 24 Vac/dc, 120 Vac, 208-277 Vac, 347 Vac or 480 Vac · Dry contact input relays do not need a transformer and operate on a dry contact closure · Low-input/optoisolated relays require less power from the controller · Mechanically latching and polarized/alarm relays · Red & NEMA 4 housings available CURRENT SENSORS · Sense currents as low as 0.125 Amp or as high as 150 Amps · Prepackaged: Sensor, LED indicators, and wires or terminals · Fixed and adjustable models · Relay/current sensor combinations available · Current transducers with 0-5 V, 0-10 V, or 4-20 mA output · Mini current switches as small as 1.5" x 2" · Self-calibrating models available AC POWER SUPPLIES · AC power supplies: 40 VA-500 VA · Single and dual transformer models · 500 VA, 300 VA, and 200 VA Class 2 power supplies (Five or three isolated, 24 Vac outputs) · LED indicator with circuit breaker / switch on each transformer available on some models · 120 Vac convenience outlets available, with or without primary 10 Amp circuit breaker · UL508 models available · High/Low voltage separation available · Prepackaged enclosure, power supply, and sub-panel kits DC POWER SUPPLIES · 300 mA, 1 Amp, or 2.5 Amp output · Adjustable output available · Class 2 models available · 120 Vac or 24 Vac input · Isolated and non-isolated · Enclosed or track mount (800) 888-5538 | www.functionaldevices.com 5 NEW & FEATURED DIN RAIL RIB® CONTROL RELAYS NO SOCKET NEEDED Our DIN RIB® No Socket Relays eliminate the need for a pluggable socket, allowing for the unit to be completely enclosed. These no socket models are priced competitively and available, along with DIN rail mounting accessories. Product Features ·Prepackaged for your convenience ·10 Amp contact rating ·10-30 Vac/dc or 24 Vac/dc coil voltage ·Transient protection ·Models available with override switch ·Current sensor models with adjustable threshold ·UL Listed Benefits ·Suitable for a wide variety of applications · Compact enclosure allows for smaller footprint on the rail · Relay & current sensor models save space in terminations ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m ADIN35ES Pair of End Stops for 35mm DIN Rail DIN MOUNT NO SOCKET RELAYS MODEL # RIBRL1C-NS COIL VOLTAGE AC/DC AC · 10-30 RELAY CONTACTS 1 SPDT RIBRL1S-NS · 10-30 1 SPDT RIBR24D-NS · 24 1 DPDT RIBR24SD-NS · 24 1 DPDT RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac CONTACT RATINGS MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) PILOT DUTY 480 VA @ 240/277 Vac 480 VA @ 240/277 Vac B300 B300 OVERRIDE SWITCH 1 # 1 # TRACK MOUNT ^ DIN Rail DIN Rail DIN Rail DIN Rail DIN MOUNT AC SENSORS WITH NO SOCKET RELAYS MODEL # RIBRXLCF-NS RIBRXLSA-NS COIL RELAY OVERRIDE SENSING VOLTAGE CONTACTS SWITCH RESISTIVE RANGE · 10-30 Vac/dc 1 SPST 10 A @ 277 Vac .25-10 A · 10-30 Vac/dc 1 SPST 1 10 A @ 277 Vac .25-10 A TYPE * Internal Internal THRESHOLD Fixed, .25 A Adjustable SENSOR CONTACT TYPE SWITCHING MAX. VOLTAGE SWITCHING RANGE CURRENT Solid State Switch Contact 30 Vac/dc .4 Amps Max Solid State Switch Contact 30 Vac/dc .4 Amps Max TRACK MOUNT ^ DIN Rail DIN Rail = UL Listed - see data sheet for specific Listing # = Coil side relay override (requires unit to be powered) * = Internal current sensor monitors current through common contact of relay ^ = Track mount sold separately DIN Rail (ADIN35) and pair of end stops (ADIN35ES) sold separately. FOR MORE PRODUCT INFORMATION, SEE PAGES 32-33 & 101. 6 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NEW & FEATURED LOW THRESHOLD CURRENT SWITCH FOR ECM APPLICATIONS Our Low Threshold Current Switch is designed to sense the increasingly low current consumption of ECM units. This ensures that an accurate status feedback of the ECM unit is transmitted back to the controller. ·Low 0.25 Amp adjustable threshold ·Sense loads up to 150 Amps ·Low hysteresis of 10% ·Requires no external power supply ·Normally open (N/O) contact output ·Prepackaged: Terminals, Two LED indicators ·Can be used in any application with lower than average current consumption ·Simple installation - only requires a screwdriver ·UL Listed ECM SENSOR VIEW VIDEO ECM UNIT Neutral Line or Load (AC Power) RIBXGTA-ECM BAS Controller Ratcheting clamp tightens around wire Foot mounting insert included Slide opening helps with installation in small spaces FOR MORE PRODUCT INFORMATION, SEE PAGE 88. (800) 888-5538 | www.functionaldevices.com 7 NEW & FEATURED NEW! RIB® CURRENT SENSORS SPLIT OR SOLID CORE CURRENT SWITCHES WITH UP TO 1 AMP SWITCHING CURRENT Our new Current Switches, with a fixed or adjustable threshold, allow up to 30 Vac/dc output with switching current rated at 1 Amp maximum. These are great for switching larger loads like starters and contactors. The split core model is available with a low sensing range down to 0.125 Amp for monitoring high efficiency motors. SOLID CORE: RIBXKNUTA ......... PAGE 87 SPLIT CORE: RIBXGNTF-125 ......... PAGE 90 SPLIT CORE TRUE RMS TRANSDUCER WITH SELECTABLE RANGE Our True RMS Current Transducer can measure the current of waveforms that are not purely sinusoidal. This enables them to be used in applications involving VFDs, phase angle dimmers, switching power supplies and more. A selectable range makes this great for various applications: 10, 20, or 50 Amps. RIBXGT420-RMS ......... PAGE 94 8 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NEW & FEATURED PREPACKAGED AC POWER SUPPLIES OFFER EASY & CONVENIENT INSTALLATION If you're planning to install a controller and other peripheral devices, it is important to consider where the items will be placed within an enclosure and how they will be powered. These kits address those needs to include a Metal Enclosure, Power Supply and Sub-panel with several prepackaged options to meet your specific needs. Wide Enclosure Single 100 VA Power Supply Perforated Steel Sub-Panel Narrow Enclosure Single 100 VA Power Supply Perforated Steel Sub-Panel Narrow Enclosure Dual 100 VA Power Supply Polymetal Sub-Panel Power Supply · Enclosed single or dual 100 VA · 10 Amp on/off circuit breaker switch(es) · 120 Vac convenience outlets · 24 Vac output terminal strip(s) · High/low voltage separation Enclosure · Two size choices · Reversible door with key latch · Sturdy 14-Gauge steel Sub-Panel · Perforated steel or polymetal · Easily removable for mounting equipment AC POWER SUPPLY PREPACKAGED KITS MODEL # CTRL-PS MHP3903100AB10 MHP3903100A100AB10 MHP3904100AB10 MHP3904100A100AB10 MHP4604100AB10 MHP4604100A100AB10 TRANSFORMER(S) 40 VA 100 VA 100 VA, 100 VA 100 VA 100 VA, 100 VA 100 VA 100 VA, 100 VA INPUT POWER 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac HEIGHT 14.500 12.500 12.500 12.500 12.500 16.150 16.150 120 VAC AUX OUT- ON/OFF MAIN BREAKER ON WIDTH DEPTH OUTLETS PUT WIRE SWITCH INPUT POWER * 7.700 3.900 · 24.500 6.500 · · · 10 A Switch/Breaker 24.500 6.500 · · · 10 A Switch/Breaker 24.500 6.500 · · · 10 A Switch/Breaker 24.500 6.500 · · · 10 A Switch/Breaker 20.000 6.720 · · · 10 A Switch/Breaker 20.000 6.720 · · · 10 A Switch/Breaker SECONDARY METAL CONFIGURATION HOUSING MH1000 SUB-PANEL / TRACK MOUNT MT212-4 included Ext. Terminal Strip MH3900 SP3803S (Polymetal) Ext. Terminal Strip MH3900 SP3803S (Polymetal) Ext. Terminal Strip MH3900 SP3804S (Perforated) Ext. Terminal Strip MH3900 SP3804S (Perforated) Ext. Terminal Strip MH4600 SP4604 (Perforated) Ext. Terminal Strip MH4600 SP4604 (Perforated) * = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A FOR MORE PRODUCT INFORMATION, SEE PAGES 120-122. (800) 888-5538 | www.functionaldevices.com 9 NEW & FEATURED AC POWER SUPPLIES WITH LOW VOLTAGE COMPARTMENT Eliminate high voltage in your control panel and the need for personal protective equipment (PPE) by using our Low Voltage Compartment Power Supplies. This series of products has a separate wiring compartment (with removable cover) to safely access the removable terminal blocks. Multi-tap Primary 480/277/240/120 Vac OR 480/347/277/240/120 Vac Perfect for providing Class 2 low voltage to central power supply panels and peripheral devices 480 277 240 120 COM ON 1 OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 Low Voltage Compartment for safe access PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC TCP-1 TCP-2 TCP-3 TCP-4 TCP-5 Features · Three or five isolated 100 VA Class 2, 24 Vac outputs with 4 Amp Breaker and individual On/Off switches. Also available with five 40 VA outputs (See chart below) · NEMA 1 metal enclosure has separate low voltage compartment with cover · Multi-tap primaries: 480/277/240/120 Vac or 480/347/277/240/120 Vac · Seismic Certification of Equipment and Components: OSP-0201-10 · UL Listed AC POWER SUPPLIES WITH LOW VOLTAGE COMPARTMENT MODEL # PSH500A-LVC TRANSFORMER(S) · 500 VA (five 100 VA Outputs) INPUT POWER 480/277/240/120 Vac HEIGHT 12.125 WIDTH 12.125 DEPTH 6.000 120 VAC BREAKER PER SECONDARY OUTLET# OUTPUT CONFIGURATION 5 x 4 Amp Terminals PSH300A-LVC · 300 VA (three 100 VA Outputs) 480/277/240/120 Vac 12.125 12.125 6.000 3 x 4 Amp Terminals PSH200A-LVC · 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac 12.125 12.125 6.000 5 x 2 Amp Terminals PSH500AB10-LVC · 500 VA (five 100 VA Outputs) 120 Vac 12.125 12.125 6.000 · 5 x 4 Amp Terminals PSH300AB10-LVC · 300 VA (three 100 VA Outputs) 120 Vac 12.125 12.125 6.000 · 3 x 4 Amp Terminals PSH200AB10-LVC · 200 VA (five 40 VA Outputs) 120 Vac 12.125 12.125 6.000 · 5 x 2 Amp Terminals = Class 2 UL Listed - see data sheet for specific Listing # = Convenience outlet has 4 Amp Breaker HOUSING STYLE Enclosed with Low Voltage Compartment Enclosed with Low Voltage Compartment Enclosed with Low Voltage Compartment Enclosed with Low Voltage Compartment Enclosed with Low Voltage Compartment Enclosed with Low Voltage Compartment FOR MORE PRODUCT INFORMATION, SEE PAGE 115-119. 10 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NEW & FEATURED RIB® DC POWER SUPPLIES WITH SINGLE OR DUAL 100 VA TRANSFORMERS · Output Power: 24 Vdc @ 2.5 Amp · Isolation, circuit breaker, status LED, ON/OFF switch, convenience outlets · Class 2 DC Power Supply · Input Power: 120 Vac FOR MORE PRODUCT INFORMATION, SEE PAGE 126. DIN RAIL MOUNT DC POWER SUPPLIES DIN MOUNT DC POWER SUPPLIES MODEL # PULS-ML15-241 PULS-PIC120-241D PULS-PIC240-241D PULS-PIM36-241 PULS-PIM60-241 PULS-PIM60-245 PULS-PIM90-241 PULS-PIM90-245 PULS-PIM90-245-L1 VOLTAGE INPUT · 100-240 Vac · 100-120Vac; 200-240Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac VOLTAGE OUTPUT Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated OUTPUT CURRENT 600 mA 5 Amp 10 Amp 1.5 Amp 2.5 Amp 2.5 Amp 3.8 Amp 3.8 Amp 3.8 Amp ON/OFF SWITCH HEIGHT 2.950 4.880 4.880 3.540" 3.540" 3.540" 3.540" 3.540" 3.540" WIDTH 0.890 1.540 1.930" 0.860" 1.420" 1.420" 1.420" 1.420" 1.420" DEPTH 3.580 4.880 4.880 3.580" 3.580" 3.580" 3.580" 3.580" 3.580" HOUSING STYLE / TRACK MOUNT DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount = Class 2 UL Listed - see data sheet for specific Listing * = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A FOR MORE PRODUCT INFORMATION, SEE WEBSITE. (800) 888-5538 | www.functionaldevices.com 11 NEW & FEATURED COMPATIBLE FAN SAFETY ALARM CIRCUIT & GENERAL PURPOSE LOGIC BOARD Our BACnet® Compatible Fan Safety Alarm Circuit & General Purpose Logic Board combines all the relay logic to facilitate fan status, fan safety control, and damper actuator control. It is intended for use in a circuit that will control fan start/stop and fan safety shut-down circuit monitors critical inputs: · Low-limit freeze protection · Static pressure (to monitor for (to stop fan and remove power high/low pressure condition) from damper actuator) · Smoke detector/fire alarm Fan Safety Mode (Factory Default) · 6 BI's for Safety Devices · 1 BI for Fan Status · 1 BO for Fan Shutdown (Safeties) · 1 BO for Fan Start · 24Vac/dc · 3 Amp Field Device Power (Actuator) · Local/Remote Reset · Latch/Unlatch DIP Switch Selectable Benefits · UL864 Safety Device · Approved California State Fire Marshal · Reduces Controller I/O · Saves Field Installation Cost · Standardized Safety Design · Local/Remote Alarm Identification · Local/Remote Reset · Stand Alone Operation General Purpose Mode · 7 BI's · 2 BO's with override: 1 SPDT 10A Relay; 1 SPDT 20A Ballast Rated Relay) RIBTWLB-7-BC NEMA 1 Housing Shown without cover RIBMNWLB-7-BC Track Mount Fan Safety Application BACnet® MS/TP BO 1-1 BO 1-2 BI 1-6 BO-2 BI 1-7 24 Vac/dc Field Devices To Motor Starter To Motor Starter N.C. or N.O. Safety Devices (Up to 6) Motor Status Air Handling Unit Fan Safety Shutdown VIEW VIDEO L1 Typical Starter Wiring L2 H M O BO 1-2 A BO 2 FOR MORE PRODUCT INFORMATION, SEE PAGE 134. 12 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NEW & FEATURED PREPACKAGED DEVICES MAKE THE JOB EASY Use these products to save I/O space on costly DDC controllers. RIBTWX2402B-BC RIBTW2401B-BC RIBMNW24B-BCAI PSH600-UPS-BC Features · MS/TP network · One binary output (20 Amp) · One binary input (dry contact) · Field addressable · DIP switch selectable baud rate · Power inputs: 24 Vac/dc or 120 / 208-277 Vac · Enclosed or track mount models · UL Listed · BTL Certified Several Devices with Varying Options · Relays · Relay & current sensor combinations · Expansion module · Analog input · Analog output · Thermistor input · Accumulator input · 600 VA UPS power supply kit · Fan safety alarm circuit/general purpose logic board FOR MORE PRODUCT INFORMATION, SEE PAGE 142-155. (800) 888-5538 | www.functionaldevices.com 13 NEW & FEATURED COMPATIBLE DEVICES APPLICATIONS Mounting your controller and peripheral devices is easy and convenient in our prepackaged solution.. See the diagrams below for examples of common uses. RIBTW2401B-BC, RIBTW2402B-BC MS/TP DO Pump or Fan Start/Stop DI Status RIBMNWX2401B-BC, RIBTWX2401B-BC, RIBMNWX2402B-BC, RIBTWX2402B-BC MS/TP DO Pump or Fan Start/Stop DI Status, Flow Switch Internal Current Sensor RIBMNW24B-BCAI, RIBTW24B-BCAI MS/TP DO DI (2) AI Exhaust Fan Start/Stop Status Room Temperature RIBTW24B-BCAO DO MS/TP DI AI AO RIBMNWD12-BCDI Pump or Fan Start/Stop Status, Flow Switch Water Temperature Valve Position MS/TP RIBMNWD12-BC MS/TP RIBMW24B-44-BC MS/TP DI (12) DI (10) ACM (2) DO (4) DI (4) Fan Wall Status or Kitchen Hood Status Pump Status Pulse Meter Pump or Fan Start/Stop Status 14 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NEW & FEATURED Local Logic Network Devices with Set Point Function for binary output Designed for remote/local applications: Cabinet unit heater, cooler/freezer, exhaust fan, fluid level - sump pump, building pressure, etc. Features · BACnet® MS/TP network · One binary output: 20 Amp SPDT + override · Two binary inputs: Dry contact · One analog input: Thermistor T2 or T3, 0-5Vdc, 0-10Vdc · 24 Vac/dc power · NEMA 1 enclosure, available in NEMA 4 enclosure · UL Listed BACnet MS/TP RIBMNW24B-BCAI 6" Mounting Track Included Set Point Differential Logic BI 1 Dry Contact Input 1 BI 2 Dry Contact Input 2 AI 1 Analog Input 0-5Vdc, 0-10Vdc T2/T3 Thermistor BO 1 SPDT 20 Amp Relay With Override RIBTW24B-BCAI NEMA 1 Housing Exhaust Fan Temperature AHU Transformer BCAI Fluid Level - Sump Pump Transformer BCAI Building Pressure Building Pressure Damper Hi Low AHU Transformer BCAI Cabinet Unit Heater Cooler/Freezer Temperature Transformer BCAI Walkin Freezer/Cooler Door Switch Audible alarm or alarm lamp FOR MORE PRODUCT INFORMATION, SEE PAGES 150-151. (800) 888-5538 | www.functionaldevices.com 15 NEW & FEATURED POWER METER KIT Introducing our new BACnet® Compatible Power Meter Kit. This Power Meter Kit includes the BACnet® Compatible Power Meter circuit board, which will collect and send all the data points to the BAS controller. Also included in this Kit is the fuse holder, fuses, and disconnect switch. Everything is prepackaged and prewired in an 18-gauge steel enclosure. This Power Meter Kit is compatible with single or three-phase electrical systems. This Kit is a great solution for revenue-grade power metering applications. · Revenue Grade Power Meter · Power Meter input power: 120-277 Vac · Made in the U.S.A · Includes 16 Amp rated Disconnect Switch * · Includes Fuse holder with three 2 Amp rated fuses ^ Dimensions: 8.3" H x 7.7" W (9.2" W with switch) x 3.9" D BACnet Power Meter Kit · Power meter circuit board · Disconnect switch · Fuse holder · Fuses RIBPM413-BC-KIT A B C N A B C REF NOT USED B(+) REMOTE STATUS NOT USED LED LED A(-) * ^ # LINE 1 CT L3 LINE 2 CT L2 LINE 3 CT L1 NEUTRAL Current Transformers See page 163 for available models FOR MORE PRODUCT INFORMATION, SEE PAGE 160. 16 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NEW & FEATURED RIB® CURRENT TRANSFORMERS CT-05A0-333 CT-100A2-333 CT-400A4-333 ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV CT-100A1-333 CT-100A4-333 CT-200A4-333 CT-025A1-333 CT-050A1-333 CTS-100A55-333 MOD1-07-33MV FDI MODEL CT-05A0-333 CT-025A1-333 CT-050A1-333 CT-100A1-333 CT-100A2-333 CT-100A4-333 CT-200A4-333 CT-400A4-333 CT-600A4-333 CTS-05A20-333 CTS-30A20-333 CTS-60A35-333 CTS-100A55-333 ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV PRIMARY INPUT (A) SECONDARY OUTPUT (V) RATIO 5 25 50 100 100 100 200 400 600 5 30 60 100 4,000 6,000 8,000 10,000 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.07 0.07 0.07 0.07 5A/0.333V 25A/0.333V 50A/0.333V 100A/0.333V 100A/0.333V 100A/0.333V 200A/0.333V 400A/0.333V 600A/0.333V 5A/0.333V 30A/0.333V 60A/0.333V 100A/0.333V 4,000/70mV 6,000/70mV 8,000/70mV 10,000/70mV ACCURACY (%) 0.3 0.8 0.5 0.5 0.75 0.5 0.5 0.5 0.5 0.2 0.2 0.2 0.2 0.75 0.75 0.75 0.75 CORE TYPE Split Split Split Split Split Split Split Split Split Solid Solid Solid Solid Rope Rope Rope Rope WINDOW SIZE .47" x .45" .72" x .62" .72" x .62" .72" x .62" 1.0" x 1.4" 1.3" x 1.7" 1.3" x 1.7" 1.3" x 1.7" 1.3" x 1.7" .2" diameter .2" diameter .35 diameter .55 diameter 5.0" diameter 7.6" diameter 11.5" diameter 15.3" diameter "MOD" & "ROPE" Series The MOD series of devices are optional modules that connect to the output of the Rogowski Coil CTs (ROPE units) and convert the output to the 0.333 V analog scale for use in other Power Monitoring systems. The MOD series has options for one, two, or three-phase power feeds. The MOD series devices are DIN rail-mountable, are ETL approved, and require 12 Vdc for input voltage. FDI MODEL MOD1-07-33MV MOD2-07-33MV MOD3-07-33MV ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV PRIINPUT (A) 0.07 0.07 0.07 4,000 6,000 8,000 10,000 SECONDARY OUTPUT (V) 0.333 0.333 0.333 0.07 0.07 0.07 0.07 ACCURACY (%) 0.50 0.50 0.50 0.75 0.75 0.75 0.75 USED WITH Any "ROPE" CT Any "ROPE" CT Any "ROPE" CT Any "MOD" CT Any "MOD" CT Any "MOD" CT Any "MOD" CT FOR MORE PRODUCT INFORMATION, SEE WEBSITE. (800) 888-5538 | www.functionaldevices.com 17 NEW & FEATURED NOTES 18 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® PILOT RELAYS: 1015 AMPS RELAYS RIBT2401D RIBH1S RIBU1C-N4 RIBMU1SC RIBRL1C-NS ENCLOSED PILOT RELAYS MODEL # RIBU1C RIBH1C RIBU2C RIBH2C RIBL3C RIBL4C RIBU1S RIBH1S RIBU1SM-250 RIBH1SM-250 RIB2401D RIB2402D RIBU1SC RIBH1SC RIBL1C-DC RIB2421C RIB2401C RIBD2421C ~ RIBU2SC RIBU2S2 COIL VOLTAGE AC/DC · 10-30 RELAY AC CONTACTS 120 1 SPDT · 10-30 208-277 1 SPDT · 10-30 120 2 SPDT · 10-30 208-277 2 SPDT · 10-30 3 SPST · 10-30 3 SPST, 1 SPDT · 10-30 120 1 SPST · 10-30 208-277 1 SPST · 10-30 120 1 SPST · 10-30 208-277 1 SPST · 24 120 1 DPDT · 24 208-277 1 DPDT · 10-30 120 1 SPDT · 10-30 208-277 1 SPDT · 10-30 Vdc only 1 SPDT · 24 120-277 1 SPDT · 24 120 1 SPDT · 24 120-277 1 SPDT · 10-30 120 1 SPST, 1 SPDT · 10-30 120 2 SPST RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 120/250 Vac 10 A @ 120/250 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac CONTACT RATINGS MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120/240 Vac (N/O) 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) PILOT DUTY 480 VA @ 240-277 Vac HIGH/LOW OVERRIDE HOUSING SEPARATION SWITCH STYLE * A SPEC PAGE 22 480 VA @ 240-277 Vac A 22 480 VA @ 240-277 Vac B 22 480 VA @ 240-277 Vac 480 VA @ 240-277 Vac · 480 VA @ 240-277 Vac · B 22 C 23 C 23 480 VA @ 277 Vac 1 B 23 480 VA @ 277 Vac 1 B 23 345 VA @ 120/240 Vac 1+monitor B 24 345 VA @ 120/240 Vac 1+monitor B 24 B300 A 24 B300 480 VA @ 277 Vac 480 VA @ 277 Vac A 24 2 + B 25 2 + B 25 480 VA @ 240-277 Vac A 25 C300 A 26 770 VA @ 250 Vac C300 · A 26 C 27 480 VA @ 277 Vac 480 VA @ 277 Vac · 1 B 28 2 C 28 = UL Listed - see data sheet for specific Listing + = SPDT with override requires 2 switches * = See Housing Guide on page 201 ^ = Track mount sold separately # = Coil side relay override (requires unit to be powered) ~ = Time Delay Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 19 RELAYS PILOT RELAYS: 1015 AMPS Convenient Prepackaging is a Great Time Saver · LED indicator · Multiple contact ratings · Override / HOA switch options available · High/low voltage separation available · 10-15 Amp models · Pre-wired · Enclosed or track mount · Time delay models T STYLE PILOT RELAYS MODEL # RIBTU1C COIL VOLTAGE RELAY AC/DC AC CONTACTS · 10-30 120 1 SPDT RIBTH1C · 10-30 208-277 1 SPDT RIBTU2C · 10-30 120 2 SPDT RIBTH2C · 10-30 208-277 2 SPDT RIBU1CW · 10-30 120 1 SPDT RIBH1CW · 10-30 208-277 1 SPDT RIBTU1S · 10-30 120 1 SPST RIBTH1S · 10-30 208-277 1 SPST RIBTU1SC · 10-30 120 1 SPDT RIBTH1SC · 10-30 208-277 1 SPDT RIBT2401D · 24 120 1 DPDT RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 15 A @ 150 Vac 15 A @ 150 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac CONTACT RATINGS MOTOR PILOT DUTY HIGH/LOW OVERRIDE HOUSING SPEC SEPARATION SWITCH STYLE * PAGE 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac · C 29 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac · C 29 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac · C 29 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac · C 29 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac · C 30 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac · C 30 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac · 1 C 30 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac · 1 C 30 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac · 2 + C 31 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac · 2 + C 31 1/2 HP @ 120-240 Vac (N/O) B300 · C 31 DIN MOUNT PILOT RELAYS MODEL # RIBRL1C-NS COIL VOLTAGE AC/DC RELAY AC CONTACTS · 10-30 1 SPDT RIBRL1S-NS · 10-30 1 SPDT RIBR24D-NS · 24 1 DPDT RIBR24SD-NS · 24 1 DPDT RIBRL1C · 10-30 1 SPDT RIBRL1S · 10-30 1 SPDT RIBR24D · 24 1 DPDT RIBR24SD · 24 1 DPDT RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac CONTACT RATINGS MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) PILOT DUTY 480 VA @ 240/277 Vac 480 VA @ 240/277 Vac B300 B300 480 VA @ 240/277 Vac 480 VA @ 240/277 Vac B300 B300 OVERRIDE SWITCH 1 # 1 # 1 # 1 # NO SOCKET · · · · TRACK SPEC MOUNT ^ PAGE DIN Rail 32 DIN Rail 32 DIN Rail 33 DIN Rail 33 DIN Rail 34 DIN Rail 34 DIN Rail 35 DIN Rail 35 = UL Listed - see data sheet for specific Listing + = SPDT with override requires 2 switches * = See Housing Guide on page 201 ^ = Track mount sold separately # = Coil side relay override (requires unit to be powered) 20 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS PPIILLOOTTRREELLAAYYSS::11001155AAMMPPSS TRACK MOUNT PILOT RELAYS MODEL # COIL VOLTAGE AC/DC AC RELAY CONTACTS RIBAN12C · 2 12 1 SPDT RESISTIVE 10 A @ 277 Vac RIBAN24C · 2 24 RIBM12C · 12 RIBM12S · 12 RIBM24C · 24 RIBM24S · 24 RIBM2401D · 24 RIBM2402D · 24 RIBMU1C · 10-30 RIBMH1C · 10-30 RIBMU1S · 10-30 RIBMH1S · 10-30 RIBMU2C · 10-30 RIBMH2C · 10-30 RIBMU1SM-250 · 10-30 RIBMH1SM-250 · 10-30 RIBMU1SC · 10-30 RIBMH1SC · 10-30 RIBMN12C · 12 RIBMN12S · 12 RIBMN24C · 24 RIBMN24S · 24 RIBMN24S-J · 24 RIBMN24C-4T · 24 RIBMN24S-4T · 24 RIBMN2401D · 24 RIBMNU1C · 10-30 RIBMNH1C · 10-30 RIBMNU1S · 10-30 RIBMNH1S · 10-30 RIBMNU1SM-250 · 10-30 RIBMNH1SM-250 · 10-30 120 208-277 120 208-277 120 208-277 120 208-277 120 208-277 120 208-277 120 120 208-277 120 208-277 120 208-277 1 SPDT 1 SPDT 1 SPST 1 SPDT 1 SPST 1 DPDT 1 DPDT 1 SPDT 1 SPDT 1 SPST 1 SPST 2 SPDT 2 SPDT 1 SPST 1 SPST 1 SPDT 1 SPDT 1 SPDT 1 SPST 1 SPDT 1 SPST 1 SPST 4 SPDT 4 SPST 1 DPDT 1 SPDT 1 SPDT 1 SPST 1 SPST 1 SPST 1 SPST 10 A @ 277 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 10 A @ 277 Vac 10 A @ 277 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 10 A @ 277 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 125 Vac 15 A @ 125 Vac CONTACT RATINGS MOTOR 1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac PILOT DUTY C300 C300 C300 OVERRIDE TRACK SPEC SWITCH MOUNT ^ PAGE MT212 Series & DIN Rail 36 MT212 Series & DIN Rail 36 MT4 Series 37 1 HP @ 250 Vac C300 1 MT4 Series 37 1 HP @ 250 Vac C300 MT4 Series 37 1 HP @ 250 Vac C300 1 MT4 Series 37 1/2 HP @ 120/240 Vac (N/O) B300 MT4 Series 38 1/2 HP @ 120/240 Vac (N/O) B300 MT4 Series 38 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac MT4 Series 38 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac MT4 Series 38 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac 1 MT4 Series 39 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac 1 MT4 Series 39 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac MT4 Series 39 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac MT4 Series 39 1/3 HP @ 120-240 Vac (N/O) 345 VA @ 120/240 Vac (N/O) 1+monitor MT4 Series 40 1/3 HP @ 120-240 Vac (N/O) 345 VA @ 120/240 Vac (N/O) 1+monitor MT4 Series 40 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac 2 + MT4 Series 40 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac 2 + MT4 Series 40 1 HP @ 250 Vac C300 MT212 Series 41 1 HP @ 250 Vac C300 1 MT212 Series 41 1 HP @ 250 Vac C300 MT212 Series 41 1 HP @ 250 Vac C300 1 MT212 Series 41 1 HP @ 250 Vac C300 1 MT212 Series 42 1 HP @ 250 Vac C300 MT212-6 Included 42 1 HP @ 250 Vac C300 4 MT212-6 Included 42 1/2 HP @ 120/240 Vac (N/O) B300 MT212 Series 43 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac MT212 Series 43 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac MT212 Series 43 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac 1 MT212 Series 44 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac 1 MT212 Series 44 1/3 HP @ 120-240 Vac (N/O) 345 VA @ 120/240 Vac (N/O) 1+monitor MT212 Series 44 1/3 HP @ 120-240 Vac (N/O) 345 VA @ 120/240 Vac (N/O) 1+monitor MT212 Series 44 = UL Listed - see data sheet for specific Listing + = SPDT with override requires 2 switches * = See Housing Guide on page 201 ^ = Track mount sold separately # = Coil side relay override (requires unit to be powered) Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 21 RELAYS 10 AMP PILOT CONTROL RELAYS RIBU1C Pilot Relay, 10 Amp SPDT, 10-30 Vac/dc/ 120 Vac Coil, NEMA 1 Housing RIBH1C Pilot Relay, 10 Amp SPDT, 10-30 Vac/dc/ 208-277 Vac Coil, NEMA 1 Housing Wht/Blk Blu 120 Vac N/C Wht/Brn Blu 208-277 Vac N/C Wht/Blu Yel 10-30 Vac/dc C Wht/Blu Yel 10-30 Vac/dc C Wht/Yel Org Comm N/O Wht/Yel Org Comm N/O RIBU1C-RD RIBH1C-RD · Red housing RIBU1C-N4 RIBH1C-N4 · NEMA 4X housing SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, C-UL, CE, RoHS (All models) UL916 (RIBU1C, RIBH1C) UL864, California State Fire Marshal (RIBU1C-RD, RIBH1C-RD) UL508 (RIBU1C-N4, RIBH1C-N4) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac (RIBU1C) 39 mA @ 208-277 Vac (RIBH1C) 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Note: Order packs by adding "-5PACK", "-10PACK", "-25PACK", or "-100PACK" to end of model number. 10 AMP PILOT CONTROL RELAYS RIBU2C Pilot Relays, 10 Amp 2 SPDT, 10-30 Vac/dc/ 120 Vac Coil, NEMA 1 Housing RIBH2C Pilot Relays, 10 Amp 2 SPDT, 10-30 Vac/dc/ 208-277 Vac Coil, NEMA 1 Housing Wht/Blk 120 Vac Blu Wht/Brn Blu N/C 208-277 Vac N/C Wht/Blu Yel Wht/Blu Yel 10-30 Vac/dc C 10-30 Vac/dc C Wht/Yel Org Wht/Yel Org Comm N/O Comm N/O Wht/Red 120 Vac Gry Wht/Org Gry N/C 208-277 Vac N/C Gry/Wht Prp Gry/Wht Prp 10-30 Vac/dc C 10-30 Vac/dc C Wht/Prp Brn Wht/Prp Brn Comm N/O Comm N/O SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.75" NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU2C) 39 mA @ 208-277 Vac (RIBH2C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 22 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 10 AMP PILOT CONTROL RELAYS RIBL3C Pilot Relays, 10 Amp 3 SPST-N/O, 10-30 Vac/dc Coil, NEMA 1 Housing RIBL4C Pilot Relays, 10 Amp 3 SPST-N/O + 1 SPDT, 10-30 Vac/dc Coil, NEMA 1 Housing Wht/Blk RELAY 1 Blk RELAY 1 Blk Wht/Blu RELAY 2 Blu RELAY 2 Blu Wht/Yel RELAY 3 Yel RELAY 3 Yel Wht/Red Comm · All relay coils use the same common · All relay coils 10-30 Vac/dc Wht/Blk RELAY 1 Wht/Blu RELAY 2 Wht/Yel RELAY 3 Wht/Brn RELAY 4 Wht/Red Comm · All relay coils use the same common · All relay coils 10-30 Vac/dc Blk RELAY 1 Blk Blu RELAY 2 Blu Yel RELAY 3 Yel Gry RELAY 4 Prp Brn SPECIFICATIONS # Relays & Contact Type: Three (3) SPST Continuous Duty Coil (RIBL3C) Three (3) SPST + One (1) SPDT Continuous Duty Coil (RIBL4C) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) 10 AMP PILOT CONTROL RELAYS RIBU1S Pilot Relay, 10 Amp SPST-N/O + Override, 10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing RIBH1S Pilot Relay, 10 Amp SPST-N/O + Override, 10-30 Vac/dc/208-277 Vac Coil, NEMA 1 Housing Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc CLOSED OPEN AUTO Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc CLOSED OPEN AUTO Wht/Yel Comm Org Wht/Yel Comm Org Org Org SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Notes: Order Normally Closed by adding "-NC" to end of model number Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: Order Normally Closed by adding "-NC" to end of model number Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1S) 39 mA @ 208-277 Vac (RIBH1S) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 23 RELAYS 10 AMP PILOT CONTROL RELAYS RIBU1SM-250 Pilot Relay, 10 Amp SPST-N/O + Override + Monitor, 10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing RIBH1SM-250 Pilot Relay, 10 Amp SPST-N/O + Override + Monitor, 10-30 Vac/dc/208-277 Vac Coil, NEMA 1 Housing Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO CLOSED OPEN AUTO Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO CLOSED OPEN AUTO AUTO C CLOSED AUTO C CLOSED Brn Prp Gry POLE 2 Org Org POLE 1 Brn Prp Gry POLE 2 Org Org POLE 1 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes + Monitor Contact Ratings: 10 Amp Resistive @ 120/250 Vac 345 VA Pilot Duty @ 120/240 Vac 211 VA Pilot Duty @ 120/240 Vac 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) Coil Current: 55 mA @ 30 Vac 28 mA @ 120 Vac (RIBU1SM-250) 39 mA @ 208-277 Vac (RIBH1SM-250) 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 250 Vac max and 5 Amp max · Order Normally Closed by adding "-NC" to end of model number 10 AMP PILOT CONTROL RELAYS RIB2401D Pilot Relay, 10 Amp DPDT, 24 Vac/dc/ 120 Vac Coil, NEMA 1 Housing RIB2402D Pilot Relay, 10 Amp DPDT, 24 Vac/dc/ 208-277 Vac Coil, NEMA 1 Housing Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu Blu N/C Wht/Brn N/C Yel 208-277 Vac Yel C C Org Org N/O N/O Wht/Blu 24 Vac/dc Gry Gry N/C N/C Prp Prp C Wht/Yel C Brn Comm Brn N/O N/O RIB2401D-RD RIB2402D-RD · Red housing RIB2401D-N4 RIB2402D-N4 · NEMA 4X housing SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Contact Ratings: Expected Relay Life: 10 million cycles minimum mechanical 10 Amp Resistive @ 30 Vdc Operating Temperature: -30 to 140° F 10 Amp General Use @ 277 Vac Humidity Range: 5 to 95% (noncondensing) 1/2 HP @ 120/240 Vac (N/O) Operate Time: 8ms 1/3 HP @ 120/240 Vac (N/C) Relay Status: LED On = Activated B300 Pilot Duty Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple 120 Vac 30A Make 3A Break (360 VA) Housing Detail: See Housing A in housing guide for dimensions 240 Vac 15 A Make 1.5A Break (360 VA) Origin: Made of US and non-US parts 208 Vac 17.3A Make 1.73A Break (360 VA) Wires: 16, 600V Rated 277 Vac 13A Make 1.3A Break (360 VA) Approvals: UL Listed, C-UL, CE, RoHS (All models) 24 Vac 30A Make 5A Break (120VA) 5A Max UL916 (RIB2401D, RIB2401D-RD, RIB2402D, RIB2402D-RD) UL864, California State Fire Marshal (RIB2401D-RD, RIB2402D-RD) UL508 (RIB2401D-N4, RIB2402D-N4) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Coil Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 30 Vdc 31 mA @ 120 Vac (RIB2401D) 36 mA @ 208-277 Vac (RIB2402D) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401D) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402D) Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc 24 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 10 AMP PILOT CONTROL RELAYS RIBU1SC Pilot Relay, 10 Amp SPDT + Override, 10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing RIBH1SC Pilot Relay, 10 Amp SPDT + Override, 10-30 Vac/dc/208-277 Vac Coil, NEMA 1 Housing Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Yel C MANUAL Wht/Yel Comm AUTO Blu N/C Org OPEN N/O N/C N/O CLOSED CLOSED Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Yel C MANUAL Wht/Yel Comm AUTO Blu N/C Org OPEN N/O N/C N/O CLOSED CLOSED SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2) 10 AMP PILOT CONTROL RELAYS RIBL1C-DC Pilot Relay, 10 Amp SPDT, 10-30 Vdc Limited Inrush Coil, NEMA 1 Housing Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1SC) 39 mA @ 208-277 Vac (RIBH1SC) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Wht/Blu Blu 10-30 Vdc N/C Yel C Wht/Yel Org Comm N/O RIBL1C-DC-RD · Red housing RIBL1C-DC-N4 · NEMA 4X housing SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, C-UL, CE, RoHS (All models) UL916 (RIBL1C-DC) UL864, California State Fire Marshal (RIBL1C-DC-RD) UL508 (RIBL1C-DC-N4) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vdc Drop Out = 2.8 Vdc Pull In = 10 Vdc Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 25 RELAYS 10 AMP PILOT CONTROL RELAYS RIB2421C Pilot Relay, 10 Amp SPDT, 24 Vac/dc/ 120-277 Vac Coil, NEMA 1 Housing Wht/Brn 120-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C GREAT SERVICE Yel TRUCK RELAY C ONE RELAY COVERS MOST APPLICATIONS Org N/O RIB2421C-RD · Red housing RIB2421C-N4 · NEMA 4X housing SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Contact Ratings: Expected Relay Life: 10 million cycles minimum mechanical 10 Amp General Use @ 277 Vac Operating Temperature: -30 to 140° F 10 Amp Resistive @ 30 Vdc (N/O) Humidity Range: 5 to 95% (noncondensing) 7 Amp Resistive @ 30 Vdc (N/C) Operate Time: 20ms 1/2 HP @ 125 Vac Relay Status: LED On = Activated 1 HP @ 250 Vac Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple 1/4 HP @ 277 Vac Housing Detail: See Housing A in housing guide for dimensions C300 Pilot Duty Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, C-UL, CE, RoHS (All models) UL916 (RIB2421C) UL864, California State Fire Marshal (RIB2421C-RD) UL508 (RIB2421C-N4) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No 10 AMP TRIVOLT CONTROL RELAYS RIB2401C TriVolt Relay, 10 Amp SPDT, 24Vac/dc or 120Vac, NEMA 1 Housing Coil Current: 66 mA @ 24 Vac 38 mA @ 24 Vdc 40 mA @ 120-277 Vac Coil Voltage Input: 24 Vac/dc ; 120-277 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Wht/Blk Blu 120 Vac N/C Wht/Blu Yel 24 Vac/dc C Wht/Yel Org Comm N/O RIB2401C-RD · Red housing RIB2401C-N4 · NEMA 4X housing SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16", 600V Rated Approvals: UL Listed, C-UL, CE, RoHS (All models) UL916 (RIB2401C) UL864, California State Fire Marshal (RIB2401C-RD) UL508 (RIB2401C-N4) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Coil Current: 24 mA @ 20 Vac 28 mA @ 24 Vac 44 mA @ 35 Vac 28 mA @ 120 Vac 13 mA @ 20 Vdc 16 mA @ 24 Vdc 25 mA @ 35 Vdc 26 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3.0 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc RELAYS 10 AMP PILOT CONTROL RELAY RIBD2421C Time Delay Pilot Relay, 10 Amp SPDT, 24 Vac/dc/120-277 Vac Coil, NEMA 1 Housing Wht/Brn Blu 120-277 Vac N/C Wht/Blu Yel 24 Vac/dc C Wht/Yel Org Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms after time delay Relay Status: RED LED On = Activated Time Delay Status: PINK LED FLASHING = Timing Timing Mode: Delay On Make (N/O) Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Input Current: 66 mA @ 24 Vac 38 mA @ 24 Vdc 40 mA @ 120-277 Vac Coil Voltage Input: 24 Vac/dc ; 120-277 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Timing Adjustment C BD AE Range Selection 1234 Only Close 1 Switch Depressed for closed Depressed for open Switch Ranges 6s-20s 22s-1min15s 1min30s-5min 6min-20min TIMING TABLE Close Dip Switch A Potentiometer Setting B C D 1 6s 9s 13s 16s 2 22s 36s 50s 1min4s 3 1min30s 2min10s 3min20s 4min16s 4 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min Coil Time Delay N/O N/C Time Delay Timing Diagram Time Delay Time Delay Time Delay Time Delay Time Delay Application Load 2 stays on selected amount of time after Load 1 goes off. Load 1 (Thermostat Controlled Heater, for example) In this example, voltage can be any voltage from 120-277 Vac. Blu Wht/Yel Neutral Blu Load 2 (Circulating Fan, for example) Yel RIB® Select RIB® with coil input appropriate to sense Load 1. Wht/Brn Yel RIBD2421C Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 27 RELAYS 10 AMP PILOT CONTROL RELAY RIBU2SC Pilot Relays, 10 Amp SPST-N/O + Override + 1 SPDT, 10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing Wht/Red Gry 120 Vac N/C Gry/Wht Prp 10-30 Vac/dc C Wht/Prp Brn Comm N/O Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO Org Org SPECIFICATIONS # Relays & Contact Type: One (1) SPST + One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.75"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes 10 AMP PILOT CONTROL RELAY RIBU2S2 Pilot Relays, 10 Amp 2 SPST-N/O + 2 Overrides, 10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc CLOSED OPEN AUTO Wht/Yel Org Comm Org Wht/Red 120 Vac Gry/Wht 10-30 Vac/dc CLOSED OPEN AUTO Wht/Prp Brn Comm Brn SPECIFICATIONS # Relays & Contact Type: Two (2) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: Order Normally Closed by adding "-NC" to end of model number Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: Order Normally Closed by adding "-NC" to end of model number 28 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 10 AMP PILOT CONTROL RELAYS RIBTU1C Pilot Relay, 10 Amp SPDT, 10-30 Vac/dc/ 120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RIBTH1C Pilot Relay, 10 Amp SPDT, 10-30 Vac/dc/ 208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Comm 10-30 Vac/dc 120 Vac Blu - N/C Yel - C Org - N/O Comm 10-30 Vac/dc 208-277 Vac Blu - N/C Yel - C Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) 10 AMP PILOT CONTROL RELAYS RIBTU2C Pilot Relays, 10 Amp 2 SPDT, 10-30 Vac/dc/ 120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RIBTH2C Pilot Relays, 10 Amp 2 SPDT, 10-30 Vac/ dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Comm 10-30 Vac/dc 120 Vac Comm 10-30 Vac/dc 120 Vac Comm 10-30 Vac/dc 208-277 Vac Comm 10-30 Vac/dc 208-277 Vac Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1C) 39 mA @ 208-277 Vac (RIBTH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Blu - N/C Yel - C Org - N/O Brn - N/O Prp - C Gry - N/C Blu - N/C Yel - C Org - N/O SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Brn - N/O Prp - C Gry - N/C Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU2C) 39 mA @ 208-277 Vac (RIBTH2C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 29 RELAYS 10 AMP PILOT CONTROL RELAYS RIBU1CW Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/ 120 Vac Coil, Hi/Lo Vertical Separation, NEMA 1 Housing RIBH1CW Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/ 208-277 Vac Coil, Hi/Lo Vertical Separation, NEMA 1 Housing Comm 10-30 Vac/dc 120 Vac Comm N/O N/O 10-30 Vac/dc N/C N/C 208-277 C Vac C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Resistive @ 150 Vac, 28Vdc 15 Amp Inductive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) 10 AMP PILOT CONTROL RELAYS RIBTU1S Pilot Relay, 10 Amp SPST + Override, 10-30 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RIBTH1S Pilot Relay, 10 Amp SPST + Override, 10-30 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Comm 10-30 Vac/dc 120 Vac Selectable Jumper Wire Org CLOSED Org OPEN AUTO Comm 10-30 Vac/dc 208-277 Vac Selectable Jumper Wire Org CLOSED Org OPEN AUTO Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1CW) 39 mA @ 208-277 Vac (RIBH1CW) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1CW) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1CW) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Notes: · Normally Open or Normally Closed selected by yellow jumper wire Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1S) 39 mA @ 208-277 Vac (RIBTH1S) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 30 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 10 AMP PILOT CONTROL RELAYS RIBTU1SC Pilot Relay, 10 Amp SPDT + Override, 10-30 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RIBTH1SC Pilot Relay, 10 Amp SPDT + Override, 10-30 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Comm 10-30 Vac/dc Blu N/C N/C - CLOSED OPEN Org N/O N/O - CLOSED Comm 10-30 Vac/dc Blu N/C N/C - CLOSED OPEN Org N/O N/O - CLOSED 120 Vac MANUAL Yel C AUTO 208-277 Vac MANUAL Yel C AUTO SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2) 10 AMP PILOT CONTROL RELAY RIBT2401D Pilot Relay, 10 Amp DPDT, 24 Vac/dc/ 120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1SC) 39 mA @ 208-277 Vac (RIBTH1SC) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 120 Vac 24 Vac/dc Comm Blu - N/C Yel - C Org - N/O Gry - N/C Prp - C Brn - N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max Coil Current: 24 mA @ 18 Vac 32 mA @ 24 Vac 40 mA @ 30 Vac 31 mA @ 120 Vac 20 mA @ 20 Vdc 24 mA @ 24 Vdc 36 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 31 RELAYS NC C NO 10 AMP PILOT CONTROL RELAY RIBRL1C-NS DIN Rail Mount Relay, 10 Amp SPDT, 10-30 Vac/dc Coil, No Socket Non-Pluggable Relay 10-30 Vac/dc N/O C ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m 2.76" 10-30V COM Comm N/C Relay LED SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Accessories: ADIN35, ADIN35ES ADIN35ES 3.88" Pair of End Stops for 35mm DIN Rail 0.78" Contact Ratings: 10 Amp Resistive @ 120/240/277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120/240 Vac (N/O) 1/6 HP @ 120/240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: Models ADIN35 and ADIN35ES sold separately. 10 AMP PILOT CONTROL RELAY RIBRL1S-NS DIN Rail Mount Relay, 10 Amp SPDT + Override, 10-30 Vac/dc Coil, No Socket Non-Pluggable Relay PWR Closed N/O CTRL Open Auto C Comm N/C PWR CTRL COM CLOSED OPEN AUTO Override Switch Relay LED Not Used Apply Continuous Power (10-30Vac/dc) to PWR and COM. Apply Coil Control (10-30Vac/dc) to CTRL and COM. NC C NO 2.76" SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m ADIN35ES 3.88" Pair of End Stops 0.78" for 35mm DIN Rail Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: Models ADIN35 and ADIN35ES sold separately. 32 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NO2 NO1 C2 C1 RELAYS 10 AMP PILOT CONTROL RELAY RIBR24D-NS DIN Rail Mount Relay, 10 Amp DPDT, 24 Vac/dc Coil, No Socket Non-Pluggable Relay 24Vac/dc Comm NC1 NO1 C1 NO2 C2 24Vac/dc COM NC1 NC2 Relay LED Not Used 2.76" ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m NC2 ADIN35ES 3.88" Pair of End Stops 0.78" for 35mm DIN Rail SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/C) B300 Pilot Duty 120Vac 30A Make 3A Break (360 VA) 240Vac 15A Make 1.5A Break (360 VA) 208Vac 17.3A Make 1.73A Break (360 VA) 277Vac 13A Make 1.3A Break (360 VA) 24Vac 30A Make 5A Break (120VA) 5A Max Power and Control Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 24 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc Notes: Models ADIN35 and ADIN35ES sold separately. 10 AMP PILOT CONTROL RELAY RIBR24SD-NS DIN Rail Mount Relay, 10 Amp DPDT + Override, 24 Vac/dc Coil, No Socket Non-Pluggable Relay CLOSED NO2 NO1 C2 C1 PWR CTRL COM PWR Closed CTRL Open Auto NO1 C1 AUTO OPEN Override Switch Relay LED Not Used ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m NC1 NC2 Comm NC1 NC2 SPECIFICATIONS NO2 C2 Apply Continuous Power (24Vac/dc) to PWR and COM. Apply Coil Control (24Vac/dc) to CTRL and COM. 2.76" 3.88" ADIN35ES Pair of End Stops 0.78" for 35mm DIN Rail # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/C) B300 Pilot Duty 120Vac 30A Make 3A Break (360 VA) 240Vac 15A Make 1.5A Break (360 VA) 208Vac 17.3A Make 1.73A Break (360 VA) 277Vac 13A Make 1.3A Break (360 VA) 24Vac 30A Make 5A Break (120VA) 5A Max Power and Control Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 24 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc Notes: Models ADIN35 and ADIN35ES sold separately. Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 33 RELAYS NC C NO 10 AMP PILOT CONTROL RELAY RIBRL1C DIN Rail Mount Relay, 10 Amp SPDT, 10-30 Vac/dc Coil, Replaceable Relay 10-30 Vac/dc N/O C Comm N/C 10-30V COM Relay LED Not Used Open Lid this Side 2.76" SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Replacement Relay: ARL1C Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m ADIN35ES Pair of End Stops 3.88" 0.78" for 35mm DIN Rail Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: Models ADIN35 and ADIN35ES sold separately. 10 AMP PILOT CONTROL RELAY RIBRL1S DIN Rail Mount Relay, 10 Amp SPDT + Override, 10-30 Vac/dc Coil, Replaceable Relay PWR Closed N/O CTRL Open Auto C PWR CTRL COM CLOSED OPEN AUTO Override Switch Relay LED Not Used Open Lid this Side NC C NO 2.76" Apply Continuous Power (10-30Vac/dc) to PWR and COM. Comm N/C Apply Coil Control (10-30Vac/dc) to CTRL and COM. SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Replacement Relay: ARL1C Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m ADIN35ES 3.88" Pair of End Stops 0.78" for 35mm DIN Rail Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: Models ADIN35 and ADIN35ES sold separately. 34 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® NO2 NO1 C2 C1 RELAYS 10 AMP PILOT CONTROL RELAY RIBR24D DIN Rail Mount Relay, 10 Amp DPDT, 24 Vac/dc Coil, Replaceable Relay 24Vac/dc Comm NC1 NC2 NO1 C1 NO2 C2 24Vac/dc COM NC1 NC2 Relay LED Not Used Open Lid this Side 2.76" 3.88" ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m ADIN35ES Pair of End Stops 0.78" for 35mm DIN Rail SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Replacement Relay: AR24D Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/C) B300 Pilot Duty 120Vac 30A Make 3A Break (360 VA) 240Vac 15A Make 1.5A Break (360 VA) 208Vac 17.3A Make 1.73A Break (360 VA) 277Vac 13A Make 1.3A Break (360 VA) 24Vac 30A Make 5A Break (120VA) 5A Max Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc Power and Control Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 24 Vdc Notes: Models ADIN35 and ADIN35ES sold separately. 10 AMP PILOT CONTROL RELAY RIBR24SD DIN Rail Mount Relay, 10 Amp DPDT + Override, 24 Vac/dc Coil, Replaceable Relay CLOSED PWR CTRL COM PWR Closed CTRL Open Auto NO1 C1 AUTO OPEN Override Switch Relay LED Not Used NO2 NO1 C2 C1 2.76" ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m NC1 NC2 Comm NC1 NC2 SPECIFICATIONS NO2 C2 Open Lid this Side Apply Continuous Power (24Vac/dc) to PWR and COM. Apply Coil Control (24Vac/dc) to CTRL and COM. 3.88" ADIN35ES 0.78" Pair of End Stops for 35mm DIN Rail # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Replacement Relay: AR24D Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/C) B300 Pilot Duty 120Vac 30A Make 3A Break (360 VA) 240Vac 15A Make 1.5A Break (360 VA) 208Vac 17.3A Make 1.73A Break (360 VA) 277Vac 13A Make 1.3A Break (360 VA) 24Vac 30A Make 5A Break (120VA) 5A Max Power and Control Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 24 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc Notes: Models ADIN35 and ADIN35ES sold separately. Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 35 RELAYS 10 AMP PILOT CONTROL TRACK OR DIN MOUNT RELAYS RIBAN12C Pilot Relay, 10 Amp SPDT, 12 Vac/dc Coil, DIN Rail Mountable, Current Sensor Mount Option, 2.75"Track Mount RIBAN24C Pilot Relay, 10 Amp SPDT, 24 Vac/dc Coil, DIN Rail Mountable, Current Sensor Mount Option, 2.75"Track Mount 12 Vac/dc 24 Vac/dc N/O N/O C C N/C N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 2.85"H x 2.75"W x 1.03"D Housing Detail: See Housing I in housing guide for dimensions Origin: Made of US and non-US parts Terminals: Removable, Accepts 22-16 AWG copper wires Mounting: A: 2.750 Track Mount MT212 Mounting Track Sold Separately. B: 35mm x 7.5mm symmetrical DIN rail EN50022 C: Screw Mount DS80625 Self-Tapping Drill Screws Sold Separately. D: Current Sensor Mount Current Sensors Sold Separately. Approvals: UL Listed, UL508, C-UL, CE, RoHS Gold Flash: No Override Switch: No RELAY MOUNTING OPTIONS A & B Mounting Option A: 2.75" Track Mount MT212 Series K G Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Voltage Input: (RIBAN12C) 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Coil Current: (RIBAN12C) 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc REMOVABLE TERMINALS Notes: · Set of replacement terminals available. Order model number: TS-AN Coil Voltage Input: (RIBAN24C) 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Coil Current: (RIBAN24C) 26 mA @ 20 Vac 31 mA @ 24 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Mounting Option B: K G 35mm x 7.5mm symmetrical DIN rail EN50022 CURRENT SENSOR MOUNTING OPTION D K RIBXK Series Mounting Tab G RIBXG Series Mounting Tab 1. Slide current sensor onto corresponding mounting tab. 2. Snap into place. 3. Depress tab to remove current sensor. 36 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 10 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBM12C Pilot Relay, 15 Amp SPDT, 12 Vac/dc Coil, 4.00" Track Mount RIBM12S Pilot Relay, 15 Amp SPST + Override, 12 Vac/dc Coil, 4.00" Track Mount RELAYS Comm N/C Comm AUTO C OPEN CLOSED C 12 Vac/dc N/O 12 Vac/dc N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBM12C) One (1) SPST Continuous Duty Coil (RIBM12S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.25"H x 4.00"W x 0.75"D1/1.25"D2 (RIBM12C) 1.25"H x 4.00"W x 1.00"D1/1.50"D2 (RIBM12S) Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: No (RIBM12C) ; Yes (RIBM12S) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty 10 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBM24C Pilot Relay, 15 Amp SPDT, 24 Vac/dc Coil, 4.00" Track Mount RIBM24S Pilot Relay, 15 Amp SPST + Override, 24 Vac/dc Coil, 4.00" Track Mount Cut for N/O Cut for N/C Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 36 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: Must cut appropriate jumper to select Normally Open or Normally Closed (RIBM12S) Comm N/C C 24 Vac/dc N/O Comm 24 Vac/dc SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBM24C) One (1) SPST Continuous Duty Coil (RIBM24S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.25"H x 4.00"W x 0.75"D1/1.25"D2 (RIBM24C) 1.25"H x 4.00"W x 1.25"D1/1.75"D2 (RIBM24S) Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: No (RIBM24C) ; Yes (RIBM24S) AUTO C OPEN CLOSED N/O or N/C Selectable Jumpers (must cut one only) Cut for N/O Cut for N/C Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: Must cut appropriate jumper to select Normally Open or Normally Closed (RIBM24S) Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 37 RELAYS 10 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBM2401D Pilot Relay, 10 Amp DPDT, 24 Vac/dc/ 120 Vac Coil, 4.00" Track Mount RIBM2402D Pilot Relay, 10 Amp DPDT, 24 Vac/dc/ 208-277 Vac Coil, 4.00" Track Mount N/O 120 Vac C N/C 24 Vac/dc N/O C Comm N/C N/O 208-277 Vac C N/C 24 Vac/dc N/O C Comm N/C SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.70"H x 4.00"W x 0.75"D1/1.25"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: No Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMU1C Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/ 120 Vac Coil, 4.00" Track Mount RIBMH1C Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/ 208-277 Vac Coil, 4.00" Track Mount Coil Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 30 Vdc 31 mA @ 120 Vac (RIBM2401D) 36 mA @ 208-277 Vac (RIBM2402D) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401D) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402D) Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc Comm N/C 10-30 Vac/dc C 120 Vac N/O Comm N/C 10-30 Vac/dc C 208-277 Vac N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.25"H x 4.00"W x 0.88"D1/1.38"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Inductive @ 150 Vac 15 Amp Resistive @ 150 Vac, 28 Vdc 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1C) 39 mA @ 208-277 Vac (RIBMH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 38 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMU1S Pilot Relay, 15 Amp SPST-N/O + Override, 10-30 Vac/dc/120 Vac Coil, 4.00" Track Mount RIBMH1S Pilot Relay, 15 Amp SPST-N/O + Override, 10-30 Vac/dc/208-277 Vac Coil, 4.00" Track Mount Comm 10-30 Vac/dc 120 Vac AUTO OPEN CLOSED Comm 10-30 Vac/dc 208-277 Vac AUTO OPEN CLOSED SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.28"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: Yes Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Notes: · Order Normally Closed by adding "-NC" to end of model number 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMU2C Pilot Relays 15 Amp 2 SPDT, 10-30 Vac/dc/ 120 Vac Coil, 4.00" Track Mount RIBMH2C Pilot Relays 15 Amp 2 SPDT, 10-30 Vac/dc/ 208-277 Vac Coil, 4.00" Track Mount Comm N/C Comm N/C 10-30 Vac/dc C 10-30 Vac/dc C 120 Vac N/O Comm N/C 208-277 Vac N/O Comm N/C 10-30 Vac/dc C 10-30 Vac/dc C 120 Vac N/O 208-277 Vac N/O Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1S) 39 mA @ 208-277 Vac (RIBMH1S) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.45"H x 4.00"W x 0.88"D1/1.38"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Inductive @ 150 Vac 15 Amp Resistive @ 150 Vac, 28 Vdc 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU2C) 39 mA @ 208-277 Vac (RIBMH2C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 39 RELAYS 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMU1SM-250 Pilot Relay, 15 Amp SPST + Override + Monitor, 10-30 Vac/dc/120 Vac Coil, 4.00" Track Mount RIBMH1SM-250 Pilot Relay, 15 Amp SPST + Override + Monitor, 10-30 Vac/dc/208-277 Vac Coil, 4.00" Track Mount Closed C Auto Comm CLOSED OPEN AUTO Selectable Jumper Wire Closed C Auto Comm CLOSED OPEN AUTO Selectable Jumper Wire 10-30 Vac/dc 120 Vac CLOSED OPEN AUTO 10-30 Vac/dc 208-277 Vac CLOSED OPEN AUTO SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.00"H x 4.00"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: Yes + Monitor Contact Ratings: 15 Amp Resistive @ 125 Vac 10 Amp Resistive @ 250 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 1/3 HP for N/O @ 120-240 Vac 1/6 HP for N/C @ 120-240 Vac Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMU1SC Pilot Relay, 15 Amp SPDT + Override, 10-30 Vac/dc/120 Vac Coil, 4.00" Track Mount RIBMH1SC Pilot Relay, 15 Amp SPDT + Override, 10-30 Vac/dc/208-277 Vac Coil, 4.00" Track Mount Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1SM-250) 39 mA @ 208-277 Vac (RIBMH1SM-250) Notes: · Normally Open or Normally Closed selected by yellow jumper wire · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 50 Vac/dc, 0.25 Amp max Comm 10-30 Vac/dc AUTO C 120 Vac MANUAL N/O N/C CLOSED CLOSED N/C OPEN N/O Comm 10-30 Vac/dc AUTO C 208-277 Vac MANUAL N/O N/C CLOSED CLOSED N/C OPEN N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.50"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1SC) 39 mA @ 208-277 Vac (RIBMH1SC) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 40 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMN12C Pilot Relay, 15 Amp SPDT, 12 Vac/dc Coil, 2.75" Track Mount RIBMN12S Pilot Relay, 15 Amp SPST + Override, 12 Vac/dc Coil, 2.75" Track Mount RELAYS Comm N/C C 12 Vac/dc N/O Comm 12 Vac/dc SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN12C) One (1) SPST Continuous Duty Coil (RIBMN12S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.10"H x 2.75"W x 0.75"D1/1.25"D2 (RIBMN12C) 1.25"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMN12S) Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: No (RIBMN12C) ; Yes (RIBMN12S) AUTO C OPEN CLOSED N/O or N/C Selectable Jumpers (must cut one only) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Cut for N/O Cut for N/C Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: (RIBMN12S) · Must cut appropriate jumper to select Normally Open or Normally Closed 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMN24C Pilot Relay, 15 Amp SPDT, 24 Vac/dc Coil, 2.75" Track Mount RIBMN24S Pilot Relay, 15 Amp SPST + Override, 24 Vac/dc Coil, 2.75" Track Mount 24 Vac/dc N/C C Comm N/O Comm 24 Vac/dc SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN24C) One (1) SPST Continuous Duty Coil (RIBMN24S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.10"H x 2.75"W x 0.75"D1/1.25"D2 (RIBMN2CS) 1.25"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMN24S) Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: No (RIBMN24C) ; Yes (RIBMN24S) AUTO C OPEN CLOSED N/O or N/C Selectable Jumpers (must cut one only) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Cut for N/O Cut for N/C Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: (RIBMN24S) · Must cut appropriate jumper to select Normally Open or Normally Closed Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 41 15 AMP PILOT CONTROL TRACK MOUNT RELAY RIBMN24S-J Pilot Relay, 15 Amp SPST + Override, 24 Vac/dc Coil, Jumper Selectable Output, 2.75" Track Mount Comm AUTO OPEN CLOSED RELAYS 24 Vac/dc Selectable Jumper Wire SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.25"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: Yes Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMN24C-4T Four Pilot Relays, 15 Amp SPDT, 24 Vac/dc Coil, 2.75" x 6.00" Track Mount RIBMN24S-4T Four Pilot Relays, 15 Amp SPST + Override, 24 Vac/dc Coil, 2.75" x 6.00" Track Mount Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: Normally Open or Normally Closed selected by yellow jumper wire. Comm N/C C 24 Vac/dc N/O Comm 24 Vac/dc AUTO C OPEN CLOSED N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: Four (4) SPDT Continuous Duty Coils (RIBMN24C-4T) Four (4) SPST Continuous Duty Coils (RIBMN24S-4T) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.25"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMN24C-4T) 1.25"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMN24S-4T) Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 x 6.000 ; MT212-6 Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: No (RIBMN24C-4T) ; Yes (RIBMN24S-4T) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S-4T) 42 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 10 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMN2401D Pilot Relay, 10 Amp DPDT, 24 Vac/dc/ 120 Vac Coil, 2.75" Track Mount N/O 120 Vac C N/C 24 Vac/dc N/O C Comm N/C SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.75"W x 0.75"D1/1.25"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: No Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max Coil Current: 36 mA @ 30Vdc 24 mA @ 18 Vac 32 mA @ 24 Vac 40 mA @ 30 Vac 31 mA @ 120 Vac 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMNU1C Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/ 120 Vac Coil, 2.75" Track Mount RIBMNH1C Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/ 208-277 Vac Coil, 2.75" Track Mount Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc Comm N/C 10-30 Vac/dc C 120 Vac N/O Comm N/C 10-30 Vac/dc C 208-277 Vac N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.75"W x 0.88"D1/1.38"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Resistive @ 150 Vac, 28Vdc 15 Amp Inductive @ 150 Vac 10 Amp Resistive @ 120-277 Vac, 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMNU1C) 39 mA @ 208-277 Vac (RIBMNH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 43 RELAYS 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMNU1S Pilot Relay, 15 Amp SPST + Override, 10-30 Vac/dc/120 Vac Coil, 2.75" Track Mount RIBMNH1S Pilot Relay, 15 Amp SPST + Override, 10-30 Vac/dc/208-277 Vac Coil, 2.75" Track Mount Comm Comm 10-30 Vac/dc 120 Vac AUTO OPEN CLOSED 10-30 Vac/dc 208-277 Vac AUTO OPEN CLOSED Selectable Jumper Wire Selectable Jumper Wire SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.53"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: Yes Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Notes: Normally Open or Normally Closed selected by yellow jumper wire 15 AMP PILOT CONTROL TRACK MOUNT RELAYS RIBMNU1SM-250 Pilot Relay, 15 Amp SPST + Override + Monitor, 10-30 Vac/dc/120 Vac Coil, 2.75 Track Mount RIBMNH1SM-250 Pilot Relay, 15 Amp SPST + Override + Monitor, 10-30 Vac/dc/208-277 Vac Coil, 2.75 Track Mount 120 Vac Selectable Jumper Wire 208-277 Vac Selectable Jumper Wire 10-30 Vac/dc Comm CLOSED OPEN AUTO AUTO C CLOSED CLOSED OPEN AUTO 10-30 Vac/dc Comm CLOSED OPEN AUTO AUTO C CLOSED CLOSED OPEN AUTO Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMNU1S) 39 mA @ 208-277 Vac (RIBMNH1S) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 3.38"H x 2.75"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes (with Monitor) Contact Ratings: 15 Amp Resistive @ 125 Vac 10 Amp Resistive @ 250 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) Notes: · Normally Open or Normally Closed selected by yellow jumper wire · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 50 Vac/dc, 0.25 Amp max Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMNU1SM-250) 39 mA @ 208-277 Vac (RIBMNH1SM-250) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 44 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER RELAYS: 2030 AMPS RIBT2401D RIB2421SB RIB2402B RIBM2401SBC RIBM24ZL Convenient Prepackaging is a Great Time Saver · LED indicator · Multiple contact ratings · Override / HOA switch options available · High/low voltage separation available · 20-30 Amp models · Pre-wired · Enclosed or track mount · Time delay models ENCLOSED POWER RELAYS COIL VOLTAGE CONTACT RATINGS RELAY MODEL # AC/DC AC CONTACTS RESISTIVE RIB2401B · 24 120 1 SPDT 20 A @ 277 Vac MOTOR 2 HP @ 277 Vac PILOT DUTY 1,110 VA @ 277 Vac HIGH/LOW OVERRIDE HOUSING SEPARATION SWITCH STYLE * B SPEC PAGE 47 RIB2402B · 24 208-277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac B 47 RIB2401SB · 24 120 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1 B 47 RIB2402SB · 24 208-277 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1 B 47 RIB2421B · 24 120/208-277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac B 48 RIB2421SB · 24 120/208-277 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 1 B 48 RIB2401SBC · 24 120 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 2 + B 48 RIB2402SBC · 24 208-277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 2 + B 48 RIB2401B2G · 24 120 1 DPDT 5 A @ 480 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac B 49 RIB2402B2G · 24 208-277 1 DPDT 5 A @ 480 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac B 49 RIB01P · 120 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac · C 49 RIB02P · 208-277 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac · C 49 RIB347P · 347 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac · C 50 RIB04P · 480 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac · C 50 RIB013P · 120 1 3PST 20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac · C 50 RIB023P · 208-277 1 3PST 20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac · C 50 RIB043P · 480 1 3PST 20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac · C 51 RIB243P · 24 1 3PST 20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac · C 51 RIB24Z RIB12P · 24 · 12 1 SPST N/O, 1 SPST N/C 1 DPDT 30 A @ 300 Vac 20 A @ 300 Vac 3 HP @ 480-600 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac Heavy Pilot Duty @ 600 Vac B 51 B 52 RIB12P30 · 12 1 DPDT 30 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac B 52 RIB24P · 24 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac B 52 RIB24P30 · 24 1 DPDT 30 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac B 52 RIB01P30 · 120 1 DPST 30 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac · C 53 RIB01P30-S · 120 1 DPST 30 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac · 1 # C 53 RIB02P30 · 208-277 1 DPST 30 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac · C 53 = UL Listed - see data sheet for specific Listing + = SPDT with override requires 2 switches * = See Housing Guide on page 201 # = Coil side relay override (requires unit to be powered) (800) 888-5538 | www.functionaldevices.com 45 RELAYS POWER RELAYS: 2030 AMPS T STYLE POWER RELAYS COIL VOLTAGE CONTACT RATINGS MODEL # RIBT24B AC/DC AC · 24 RELAY CONTACTS 1 SPDT RESISTIVE 20 A @ 277 Vac MOTOR 2 HP @ 277 Vac PILOT DUTY 1,110 VA @ 277 Vac HIGH/LOW OVERRIDE HOUSING SPEC SEPARATION SWITCH STYLE * PAGE · C 54 RIBT24SB · 24 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · 1 C 54 RIBT2401B · 24 120 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · C 54 RIBT2402B · 24 208-277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · C 54 RIBT2401SB · 24 120 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · 1 C 55 RIBT2402SB · 24 208-277 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · 1 C 55 RIBT2401SBC · 24 120 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · 2 + C 55 RIBT2402SBC · 24 208-277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · 2 + C 55 RIBTD2401B ~ · 24 120 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · C 56 RIBT242B · 24 2 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · C 57 RIBT243B RIBT24P · 24 · 24 2 SPST, 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac · C 57 C 57 RIBT24Z RIBT243P · 24 · 24 1 SPST N/O, 1 SPST N/C 30 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac · 3PST 20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac · C 58 C 58 TRACK MOUNT POWER RELAYS COIL VOLTAGE MODEL # RIBM2401B RIBM2402B RIBM2401SB RIBM2402SB RIBM2401SBC RIBM2402SBC AC/DC · 24 · 24 · 24 · 24 · 24 · 24 AC 120 208-277 120 208-277 120 208-277 RELAY CONTACTS 1 SPDT 1 SPDT 1 SPST 1 SPST 1 SPDT 1 SPDT RESISTIVE 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac CONTACT RATINGS MOTOR 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac PILOT DUTY 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac OVERRIDE TRACK SPEC SWITCH MOUNT ^ PAGE MT4 Series 59 MT4 Series 59 1 MT4 Series 59 1 MT4 Series 59 2 + MT4 Series 60 2 + MT4 Series 60 RIBM24ZN 24 RIBM24ZL · 24 RIBMN24ZL · 24 1 DPDT 1 DPST 1 DPST 30 A @ 300 Vac 30 A @ 300 Vac 30 A @ 300 Vac 3 HP @ 480-600 Vac 3 HP @ 480-600 Vac 3 HP @ 480-600 Vac NEMA B600 Heavy Pilot Duty @ 600 Vac Heavy Pilot Duty @ 600 Vac MT4 Series 60 MT4 Series 61 MT212 Series 61 RIBM243PN 24 1 3PDT 30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac MT4 Series 61 RIBM013PN 120 1 3PDT 30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac MT4 Series 62 RIBM023PN 208-277 1 3PDT 30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac MT4 Series 62 RIBM043PN 480 1 3PDT 30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac MT4 Series 63 RIBM043PN-HD 480 1 3PDT 30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac MT4 Series 63 = UL Listed - see data sheet for specific Listing = UL Component Recognized - see data sheet for specific Listing ~ = Time Delay + = SPDT with override requires 2 switches * = See Housing Guide on page 201 ^ = Track mount sold separately 46 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 20 AMP POWER CONTROL RELAYS RIB2401B Power Relay, 20 Amp SPDT, 24 Vac/dc/120 Vac Coil, NEMA 1 Housing RIB2402B Power Relay, 20 Amp SPDT, 24 Vac/dc/208-277 Vac Coil, NEMA 1 Housing Wht/Blk Blu 120 Vac N/C Wht/Blu Yel 24 Vac/dc C Wht/Yel Org Comm N/O Wht/Brn Blu 208-277 Vac N/C Wht/Blu Yel 24 Vac/dc C Wht/Yel Org Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIB2401B) 69mA @ 208-277 Vac (RIB2402B) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 20 AMP POWER CONTROL RELAYS RIB2401SB Power Relay, 20 Amp SPST-N/O + Override, 24 Vac/dc/120 Vac Coil, NEMA 1 Housing RIB2402SB Power Relay, 20 Amp SPST-N/O + Override, 24 Vac/dc/208-277 Vac Coil, NEMA 1 Housing Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO Org Org Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO Org Org SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc (800) 888-5538 | www.functionaldevices.com Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIB2401SB) 69 mA @ 208-277 Vac (RIB2402SB) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 47 RELAYS 20 AMP POWER CONTROL RELAYS RIB2421B Power Relay, 20 Amp SPDT, 24 Vac/dc/120 Vac/208-277 Vac Coil, NEMA 1 Housing RIB2421SB Power Relay, 20 Amp SPST-N/O + Override, 24 Vac/dc/208-277 Vac/120 Vac Coil, NEMA 1 Housing Wht/Brn Blu 208-277 Vac N/C Wht/Blk 120 Vac Yel C Wht/Blu 24 Vac/dc Wht/Yel Org Comm N/O Wht/Brn 208-277 Vac Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO Org Org SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIB2421B) One (1) SPST Continuous Duty Coil (RIB2421SB) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (RIB2421SB) No (RIB2421B) Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) (RIB2421SB) Not rated for Electronic Ballast (RIB2421SB) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac 20 AMP POWER CONTROL RELAYS RIB2401SBC Power Relay, 20 Amp SPDT + Override, 24 Vac/dc/120 Vac Coil, NEMA 1 Housing RIB2402SBC Power Relay, 20 Amp SPDT + Override, 24 Vac/dc/208-277 Vac Coil, NEMA 1 Housing Coil Current: 83 mA @ 24 Vac 47 mA @ 120 Vac 69 mA @ 208-277 Vac 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 208-277 Vac ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Notes: · Order RIB2421SB Normally Closed by adding "-NC" to end of model number Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Yel C MANUAL Wht/Yel Comm AUTO Blu N/C Org OPEN N/O N/C N/O CLOSED CLOSED Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Yel C MANUAL Wht/Yel Comm AUTO Blu N/C Org OPEN N/O N/C N/O CLOSED CLOSED SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIB2401SBC) 69 mA @ 208-277 Vac (RIB2402SBC) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 48 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 20 AMP POWER CONTROL RELAYS RIB2401B2G Power Relay, 20 Amp DPDT, 24 Vac/dc/120 Vac Coil, NEMA 1 Housing RIB2402B2G Power Relay, 20 Amp DPDT, 24 Vac/dc/208-277 Vac Coil, NEMA 1 Housing Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel C Org N/O Gry N/C Prp C Brn N/O Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel C Org N/O Gry N/C Prp C Brn N/O SPECIFICATIONS # Relays & Contact Type: DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .75 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 A @ 277 Vac General Purpose 20 A @ 28 Vdc 1 HP @ 120 Vac 2 HP @ 277 Vac 2 HP @ 240 Vac (N/O) 1 HP @ 208 Vac (N/O) 20 A Ballast @ 277 Vac 15 A Tungsten @ 120 Vac (N/O) 5 A @ 480 Vac Resistive 16 A @ 277 Vac Electronic Ballast (N/O) 1,110 VA Pilot Duty @ 277 Vac 1,158 VA Pilot Duty @ 240 Vac (N/O) 770 VA Pilot Duty @ 208 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 2 A Tungsten @ 120 Vac (N/C) 20 AMP POWER CONTROL RELAYS RIB01P Power Relay, 20 Amp DPDT, 120 Vac Coil, NEMA 1 Housing RIB02P Power Relay, 20 Amp DPDT, 208-277 Vac Coil, NEMA 1 Housing Blu N/C Wht/Blk 120 Vac Yel C Org N/O Gry N/C Wht/Blk Prp 120 Vac C Brn N/O Blu N/C Wht/Brn 208-277 Vac Yel C Org N/O Gry N/C Wht/Brn Prp 208-277 Vac C Brn N/O Coil Current: 145 mA max @ 24 Vac 65 mA max @ 30 Vdc 107 mA max @ 120 Vac (RIB2401B2G) 140 mA max @ 208-277 Vac (RIB2402B2G) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401B2G) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402B2G) Drop Out = 13.5 Vac / 15.5 Vdc Pull In = 18 Vac / 22 Vdc SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Coil Current: 105 mA @ 120 Vac (RIB01P) 105 mA @ 208-277 Vac (RIB02P) Coil Voltage Input: RIB01P 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac RIB02P 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac 49 RELAYS 20 AMP POWER CONTROL RELAYS RIB347P Power Relay, 20 Amp DPDT, 347 Vac Coil, NEMA 1 Housing RIB04P Power Relay, 20 Amp DPDT, 480 Vac Coil, NEMA 1 Housing Blu N/C Wht/Org 347 Vac Yel C Org N/O Gry N/C Wht/Org Prp 347 Vac C Brn N/O Blu N/C Wht/Grn 480 Vac Yel C Org N/O Gry N/C Wht/Grn Prp 480 Vac C Brn N/O SPECIFICATIONS DRY CONTACT INPUT RELAY # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS (Both Models) UL864, California State Fire Marshal (RIB04P) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac 15 Amp Resistive @ 600 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac 20 AMP POWER CONTROL RELAYS RIB013P Power Relay, 20 Amp, 3PST-N/O, 120 Vac Coil, NEMA 1 Housing RIB023P Power Relay, 20 Amp, 3PST-N/O, 208-277 Vac Coil, NEMA 1 Housing Wht/Blk 120 Vac Wht/Blk 120 Vac Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O Wht/Brn 208-277 Vac Wht/Brn 208-277 Vac Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1,158 VA Pilot Duty @ 240 Vac, 1 Phase 1,110 VA Pilot Duty @ 277 Vac, 1 Phase 1,640 VA Pilot Duty @ 480 Vac, 1 Phase 1,466 VA Pilot Duty @ 240 Vac, 3 Phase 2,112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Coil Current: 105 mA @ 347 Vac (RIB347P) 105 mA @ 480 Vac (RIB04P) Coil Voltage Input: RIB347P 347 Vac ; 50-60 Hz Drop Out = 70 Vac Pull In = 295 Vac RIB04P 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac Coil Current: 154 mA @ 120 Vac (RIB013P) 187 mA @ 208-277 Vac (RIB023P) Coil Voltage Input: RIB013P 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac RIB023P 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number 50 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 20 AMP POWER CONTROL RELAYS RIB043P Power Relay, 20 Amp 3PST-N/O, 480 Vac Coil, NEMA 1 Housing RIB243P Power Relay, 20 Amp 3PST-N/O, 24 Vac/dc Coil, NEMA 1 Housing Wht/Grn 480 Vac Wht/Grn 480 Vac Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O Wht/Yel 24 Vac/dc Wht/Yel 24 Vac/dc Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS (Both Models) UL864, California State Fire Marshal (RIB043P) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1,158 VA Pilot Duty @ 240 Vac, 1 Phase 1,110 VA Pilot Duty @ 277 Vac, 1 Phase 1,640 VA Pilot Duty @ 480 Vac, 1 Phase 1,466 VA Pilot Duty @ 240 Vac, 3 Phase 2,112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase 30 AMP POWER CONTROL RELAY RIB24Z Power Relay, 30 Amp SPST-N/O + SPST-N/C, 24 Vac/dc Coil, NEMA 1 Housing Wht/Yel Blu 24 Vac/dc N/C Blu N/C Org N/O Wht/Yel 24 Vac/dc Org N/O Coil Current: 132 mA @ 480 Vac (RIB043P) 210 mA @ 24 Vac (RIB243P) 154 mA @ 30 Vdc (RIB243P) Coil Voltage Input: RIB043P 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac RIB243P 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number SPECIFICATIONS # Relays & Contact Type: One (1) SPST-N/O + SPST-N/C Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390 x 3.310 x 1.810 with .50 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc (800) 888-5538 | www.functionaldevices.com 51 RELAYS 20 AMP POWER CONTROL RELAYS RIB12P Power Relay, 20 Amp DPDT, 12 Vac/dc Coil, NEMA 1 Housing RIB12P30 Power Relay, 30 Amp DPDT, 12 Vac/dc Coil, NEMA 1 Housing Blu N/C Wht/Yel 12 Vac/dc Yel C Org N/O Gry N/C Wht/Yel Prp 12 Vac/dc C Brn N/O Blu N/C Wht/Yel Yel 12 Vac/dc C Org N/O Gry N/C Wht/Yel Prp 12 Vac/dc C Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple (RIB12P) 2.390H x 3.310W x 1.810D with .75 NPT Nipple (RIB12P30) Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: (RIB12P) 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Contact Ratings: (RIB12P30) 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 115 mA @ 10 Vac 180 mA @ 12 Vac 79 mA @ 11 Vdc 90 mA @ 12 Vdc 115 mA @ 15 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 4.5 Vac / 4.8 Vdc Pull In = 9.7 Vac / 11 Vdc 20 / 30 AMP POWER CONTROL RELAYS RIB24P Power Relay, 20 Amp DPDT, 24 Vac/dc Coil, NEMA 1 Housing RIB24P30 Power Relay, 30 Amp DPDT, 24 Vac/dc Coil, NEMA 1 Housing Blu N/C Wht/Yel 24 Vac/dc Yel C Org N/O Gry N/C Wht/Yel Prp 24 Vac/dc C Brn N/O Blu N/C Wht/Yel Yel 24 Vac/dc C Org N/O Gry N/C Wht/Yel Prp 24 Vac/dc C Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Contact Ratings: (RIB24P) Expected Relay Life: 10 million cycles minimum mechanical 20 Amp Resistive @ 300 Vac Operating Temperature: -30 to 140° F 20 Amp Resistive @ 28 Vdc Humidity Range: 5 to 95% (noncondensing) 20 Amp Ballast @ 277-480 Vac Operate Time: 18ms Not rated for Electronic Ballast Relay Status: LED On = Activated 15 Amp Resistive @ 600 Vac Dimensions: 2.390 x 3.310 x 1.810 with .50 NPT Nipple 770 VA Pilot Duty @ 120 Vac Housing Detail: See Housing B in housing guide for dimensions 1,158 VA Pilot Duty @ 240 Vac Origin: Made of US and non-US parts 1,109 VA Pilot Duty @ 277 Vac Wires: 16, 600V Rated 1,640 VA Pilot Duty @ 480 Vac Approvals: UL Listed, UL916, UL864, UL60947, C-UL Heavy Pilot Duty @ 600 Vac California State Fire Marshal, CE, RoHS 3 HP @ 480-600 Vac Housing Rating: UL Accepted for Use in Plenum, NEMA 1 2 HP @ 240-277 Vac Gold Flash: Yes 1 HP @ 120 Vac Override Switch: No Contact Ratings: (RIB24P30) 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 52 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 30 AMP POWER CONTROL RELAYS RIB01P30 Power Relay, 30 Amp DPST-N/O, 120 Vac Coil, NEMA 1 Housing RIB01P30-S Power Relay, 30 Amp DPST-N/O + Coil Side Override, 120 Vac Coil, NEMA 1 Housing Org Org N/O N/O Wht/Blk 120 Vac Pole 1 Wht/Blk 120 Vac Continuous HAND Org N/O Wht/Red OFF Org N/O 120 Vac Control AUTO Brn Brn N/O N/O Wht/Blk 120 Vac Pole 2 Wht/Yel Brn Neutral Brn N/O N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No (RIB01P30) Coil Side (RIB01P30-S) Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac 30 AMP POWER CONTROL RELAY RIB02P30 Power Relay, 30 Amp DPST-N/O, 208-277 Vac Coil, NEMA 1 Housing Wht/Brn 208-277 Vac Wht/Brn 208-277 Vac Org N/O Pole 1 Org N/O Brn N/O Pole 2 Brn N/O Coil Current: 105 mA @ 120 Vac Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac Control Input: Wht/Blk = 120 Vac Continuous Wht/Red = 120 Vac Control Wht/Yel = Neutral Notes: · Order Both Poles Normally Closed by adding "-NC" to end of model number · Order Pole 1 Normally Open and Pole 2 Normally Closed by adding "-NONC" to end of model number SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Coil Current: 105 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac Notes: · Order Both Poles Normally Closed by adding "-NC" to end of model number · Order Pole 1 Normally Open and Pole 2 Normally Closed by adding "-NONC" to end of model number 53 RELAYS 20 AMP POWER CONTROL RELAYS RIBT24B Power Relay, 20 Amp SPDT, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RIBT24SB Power Relay, 20 Amp SPST + Override, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Blu 24 Vac/dc N/C Yel C Org Comm N/O 24 Vac/dc Comm Selectable Jumper Wire Org CLOSED Org OPEN AUTO SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBT24B) One (1) SPST Continuous Duty Coil (RIBT24SB) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIBT24B) Yes (RIBT24SB) 20 AMP POWER CONTROL RELAYS Contact Ratings: (RIBT24B) 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 45 mA @ 18 Vac 75 mA @ 24 Vac 30 mA @ 22 Vdc 32 mA @ 24 Vdc 42 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc RIBT2401B Power Relay, 20 Amp SPDT, 24 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RIBT2402B Power Relay, 20 Amp SPDT, 24 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Contact Ratings: (RIBT24SB) 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Notes: · Normally Open or Normally Closed selected by yellow jumper wire (RIBT24SB) Blu 120 Vac N/C Yel 24 Vac/dc C Org Comm N/O Blu 208-277 Vac N/C Yel 24 Vac/dc C Org Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401B) 69 mA @ 208-277 Vac (RIBT2402B) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 54 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 20 AMP POWER CONTROL RELAYS RIBT2401SB Power Relay, 20 Amp SPST + Override, 24 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RIBT2402SB Power Relay, 20 Amp SPST + Override, 24 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Selectable Jumper Wire Selectable Jumper Wire 120 Vac Org 208-277 Vac Org 24 Vac/dc Comm CLOSED Org OPEN AUTO 24 Vac/dc Comm CLOSED Org OPEN AUTO SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS (RIBT2401SB) UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS (RIBT2402SB) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401SB) 69 mA @ 208-277 Vac (RIBT2402SB) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Notes: · Normally Open or Normally Closed selected by yellow jumper wire 20 AMP POWER CONTROL RELAYS RIBT2401SBC Power Relay, 20 Amp SPDT + Override, 24 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RIBT2402SBC Power Relay, 20 Amp SPDT + Override, 24 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing 120 Vac 208-277 Vac 24 Vac/dc 24 Vac/dc Comm Comm Yel MANUAL C AUTO Blu N/C - CLOSED N/C OPEN Org N/O - CLOSED N/O Yel MANUAL C AUTO Blu N/C - CLOSED N/C OPEN Org N/O - CLOSED N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401SBC) 69 mA @ 208-277 Vac (RIBT2402SBC) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc (800) 888-5538 | www.functionaldevices.com 55 RELAYS 20 AMP TIME DELAY RELAY RIBTD2401B Time Delay Power Relay, 20 Amp SPDT, 24 Vac/dc/120 Vac Coil, NEMA 1 Housing Blu 120 Vac N/C Yel 24 Vac/dc C Org Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms after time delay Relay Status: RED LED On = Activated Time Delay Status: PINK LED FLASHING = Timing Timing Mode: Delay On Make (N/O) Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: Input Current: 20 Amp Resistive @ 277 Vac 133 mA @ 24 Vac 20 Amp Ballast @ 277 Vac 45 mA @ 24 Vdc 16 Amp Electronic Ballast @ 277 Vac (N/O) 51 mA @ 120 Vac 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Timing Adjustment Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc C BD AE Range Selection 1234 Only Close 1 Switch Depressed for closed Depressed for open Switch Ranges 6s-20s 22s-1min15s 1min30s-5min 6min-20min TIMING TABLE Close Dip Switch A Potentiometer Setting B C D 1 6s 9s 13s 16s 2 22s 36s 50s 1min4s 3 1min30s 2min10s 3min20s 4min16s 4 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min Time Delay Application Example #1 Load 2 stays ON selected amount of time after Load 1 turns ON (N/C) Load 2 stays OFF selected amount of time after Load 1 turns ON (N/O) Load 1 (Thermostat Controlled Heater, for example) 120 Vac Blu Time Delay Application Example #2 (Requires an Inverting Relay) Load 2 stays ON selected amount of time after Load 1 turns OFF (N/C) Load 2 stays OFF selected amount of time after Load 1 turns OFF (N/O) 120 Vac Hot Load 1 (Thermostat Blu Controlled Heater, for example) Blu Load 2 (Circulating Fan, for example) Load 1 Voltage Load 2 on N/O Contact Load 2 on N/C Contact Yel RIBTD2401B Time Delay Time Delay Load 2 (Circulating Fan, for example) Present Absent ON OFF ON OFF Yel Yel RIB® Select RIB® with coil input appropriate to sense Load 1. RIBTD2401B Neutral Load 1 Voltage Load 2 on N/O Contact Load 2 on N/C Contact Time Delay Time Delay Present Absent ON OFF ON OFF 56 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 20 AMP POWER CONTROL RELAYS RIBT242B Power Relays, 20 Amp 2 SPDT, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RIBT243B Power Relays, 20 Amp 2 SPST-N/O + 1 SPDT, 24 Vac/dc Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RELAY 2 24 Vac/dc Gry - N/C Prp - C RELAY 1 24 Vac/dc Brn - N/O Blu - N/C Comm Yel - C Org - N/O All relay coils use the same common RELAY 3 24 Vac/dc Gry - N/C Prp - C RELAY 2 24 Vac/dc Brn - N/O Yel - N/O RELAY 1 24 Vac/dc Yel - N/O Blu - N/O Comm Blu - N/O All relay coils use the same common SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil (RIBT242B) Two (2) SPST + One (1) SPDT Continuous Duty Coil (RIBT243B) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.800D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, C-UL, CE, RoHS (Both Models) UL916 (RIBT243B) UL864 , California State Fire Marshal (RIBT242B) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No 20 AMP POWER CONTROL RELAY RIBT24P Power Relay, 20 Amp DPDT, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 24 Vac/dc Comm Blu - N/C Yel - C Org - N/O Gry - N/C Prp - C Brn - N/O Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Notes: · RIBT243B not rated for UL864 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.800D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 57 30 AMP POWER CONTROL RELAY RIBT24Z Power Relay, 30 Amp SPST-N/O + SPST-N/C, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing RELAYS 24 Vac/dc Comm Blu - N/C Blu - N/C Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPST-N/O + One (1) SPST-N/C Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.800D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 20 AMP POWER CONTROL RELAY RIBT243P Power Relay, 20 Amp 3PST-N/O, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing 24 Vac/dc Comm Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.800D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1,158 VA Pilot Duty @ 240 Vac, 1 Phase 1,110 VA Pilot Duty @ 277 Vac, 1 Phase 1,640 VA Pilot Duty @ 480 Vac, 1 Phase 1,466 VA Pilot Duty @ 240 Vac, 3 Phase 2,112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 58 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS 20 AMP TRACK MOUNT CONTROL RELAYS RIBM2401B Power Relay, 20 Amp SPDT, 24 Vac/dc/120 Vac Coil, 4.00" Track Mount RIBM2402B Power Relay, 20 Amp SPDT, 24 Vac/dc/208-277 Vac Coil, 4.00" Track Mount C Comm N/O 24 Vac/dc 120 Vac N/C C Comm N/O 24 Vac/dc 208-277 Vac N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.250H x 4.000W x 0.880"D1/1.380"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac 20 AMP TRACK MOUNT CONTROL RELAYS RIBM2401SB Power Relay, 20 Amp SPST + Override, 24 Vac/dc/120 Vac Coil, 4.00" Track Mount RIBM2402SB Power Relay, 20 Amp SPST + Override, 24 Vac/dc/208-277 Vac Coil, 4.00" Track Mount Comm Selectable Jumper Wire Comm Selectable Jumper Wire 24 Vac/dc 120 Vac CLOSED OPEN AUTO Not Used 24 Vac/dc 208-277 Vac CLOSED OPEN AUTO Not Used Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBM2401B) 69 mA @ 208-277 Vac (RIBM2402B) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.60"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Notes: · Normally Open or Normally Closed selected by yellow jumper wire Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBM2401B) 69 mA @ 208-277 Vac (RIBM2402B) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc (800) 888-5538 | www.functionaldevices.com 59 20 AMP TRACK MOUNT CONTROL RELAYS RIBM2401SBC Power Relay, 20 Amp SPDT + Override, 24 Vac/dc/120 Vac Coil, 4.00" Track Mount RIBM2402SBC Power Relay, 20 Amp SPDT + Override, 24 Vac/dc/208-277 Vac Coil, 4.00" Track Mount RELAYS Comm 24 Vac/dc 120 Vac AUTO C MANUAL N/C N/O CLOSED CLOSED N/O OPEN N/C Comm 24 Vac/dc 208-277 Vac AUTO C MANUAL N/C N/O CLOSED CLOSED N/O OPEN N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.40"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes (2) 30 AMP TRACK MOUNT CONTROL RELAY RIBM24ZN Power Relay, 30 Amp DPDT, 24 Vac/dc Coil, 4.00" Track Mount Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBM2401SBC) 69 mA @ 208-277 Vac (RIBM2402SBC) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc N/C 24 Vac/dc N/O C N/C Comm N/O C SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.38"H x 4.00"W x 1.50"D1/2.00"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac NEMA B600 Pilot Duty 60 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® Coil Current: 110 mA @ 20 Vac 125 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 70 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc RELAYS 30 AMP TRACK MOUNT CONTROL RELAYS RIBM24ZL Power Relay, 30 Amp DPST-N/O, 24 Vac/dc Coil, 4.00" Track Mount RIBMN24ZL Power Relay, 30 Amp DPST-N/O, 24 Vac/dc Coil, 2.75" Track Mount C Comm N/O C 24 Vac/dc N/O C Comm N/O C 24 Vac/dc N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.50"H x 4.00"W x 2.25"D1/2.75"D2 (RIBM24ZL) 2.50"H x 2.75"W x 2.25"D1/2.75"D2 (RIBMN24ZL) Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 (RIBM24ZL) or 2.750"(RIBMN24ZL) Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No 30 AMP TRACK MOUNT CONTROL RELAY RIBM243PN Power Relay, 30 Amp 3PDT, 24 Vac/dc Coil, 4.00" Track Mount Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Notes: Order Normally Closed by adding "-NC" to end of model number N/C N/O C N/C 24 Vac/dc N/O C N/C Comm N/O C SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Housing Detail: See Housing H in housing guide for dimensions Dimensions: 2.38"H x 4.00"W x 1.50"D1/2.00"D2 Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase (800) 888-5538 | www.functionaldevices.com Coil Current: 190 mA @ 24 Vac 140 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc 61 RELAYS 30 AMP TRACK MOUNT CONTROL RELAY RIBM013PN Power Relay, 30 Amp 3PDT, 120 Vac Coil, 4.00" Track Mount N/C N/O C N/C Comm N/O C N/C Not Used 120 Vac N/O C SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.38"H x 4.00"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No 30 AMP TRACK MOUNT CONTROL RELAY RIBM023PN Power Relay, 30 Amp 3PDT, 208-277 Vac Coil, 4.00" Track Mount Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase N/C N/O C N/C Comm N/O C N/C Not Used 208-277 Vac N/O C SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.38"H x 4.00"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase 62 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® Coil Current: 140 mA @ 120 Vac Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac Coil Current: 170 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac 30 AMP TRACK MOUNT CONTROL RELAY RIBM043PN Power Relay, 30 Amp 3PDT, 480 Vac Coil, 4.00" Track Mount RELAYS N/C N/O C N/C Comm N/O C Not Used N/C 480 Vac N/O C SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.38"H x 4.00"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase 30 AMP TRACK MOUNT CONTROL RELAY RIBM043PN-HD Heavy Duty Relay, 30 Amp 3PDT, 480 Vac Coil, For Use in More Transient Prone Environments, 4.00" x 3.25"Track Mount Coil Current: 140 mA @ 120 Vac Coil Voltage Input: 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac Notes: See model RIBM043PN-HD for use in more transient prone environments N/C N/O C N/C Comm N/O C Not Used N/C 480 Vac N/O C SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 3.25"H x 4.00"W x 1.50"D1/2.00"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase Coil Current: 140 mA @ 480 Vac Coil Voltage Input: 480 Vac/dc ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac (800) 888-5538 | www.functionaldevices.com 63 LATCHING RELAYS RELAYS RIBL24BM RIBL24B RIBL12SB These relays are switched by pulse commands from an appropriate power source or a controller. The relay contacts are mechanically latched in position, so that the load remains in its last state (on or off) during a loss of power. A pulse of opposing polarity latches the relay in the alternate state. Product Features · Prepackaged for quick and easy installation · Electromechanical relay · Mechanically latching · Status LED and auxiliary ouput models available · Electronic ballast rating · 20 Amp rating Typical Application 24 Vac Supply Latch Unlatch On Controller Comm O N/O Momentary Wall Switch Local Power 120-277 Vac Lighting Status to Controller N/O Momentary Wall Switch ENCLOSED LATCHING RELAYS MODEL # RIBL12B COIL VOLTAGE AC/DC RELAY CONTACTS RESISTIVE · 12 1 SPST 20 A @ 120-277 Vac CONTACT RATINGS MOTOR 3 HP @ 240 Vac PILOT DUTY 720 VA @ 120-277 Vac OVERRIDE SWITCH AUXILIARY OUTPUT HOUSING STYLE * A SPEC PAGE 65 RIBL12BM · 12 1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac 720 VA @ 120-277 Vac · B 65 RIBL12SB · 12 1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac 720 VA @ 120-277 Vac · A 65 RIBL12SBM · 12 1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac 720 VA @ 120-277 Vac · · B 65 RIBL24B · 24 1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac 720 VA @ 120-277 Vac A 66 RIBL24BM · 24 1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac 720 VA @ 120-277 Vac · B 66 RIBL24SB · 24 1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac 720 VA @ 120-277 Vac · A 66 RIBL24SBM · 24 1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac 720 VA @ 120-277 Vac · · B 66 = UL Listed - see data sheet for specific Listing * = See Housing Guide on page 201 64 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS LATCHING RELAY RIBL12B Mechanically Latching Relay, 20 Amp SPST, 12 Vac/dc Coil, NEMA 1 Housing Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Wht/Red 12 Vac/dc () UNLATCH Org Line Org Load RIBL12BM Mechanically Latching Relay, 20 Amp SPST, 12 Vac/dc Coil, Status LED, Auxiliary Output, NEMA 1 Housing Yel Line Wht/Blu 12 Vac/dc () LATCH Org Load Wht/Yel 12 Vac/dc (+) Wht/Blk Load Neutral Wht/Red 12 Vac/dc () UNLATCH Gry AUXILIARY CONTACT Gry RIBL12B-RD · Red housing RIBL12B-N4 · NEMA 4X housing SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary: (RIBL12BM) Contact Closed: LED On = Voltage Detected on Load Wire (RIBL12BM) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple (RIBL12B) 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple (RIBL12BM) Housing Detail: See Housing A (RIBL12B) or Housing B (RIBL12BM) in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 182 mA @ 10 Vac 20 Amp Ballast @ 120-277 Vac 250 mA @ 12 Vac 16 Amp Electronic Ballast @ 120-277 Vac 165 mA @ 10 Vdc 5540 Watt Tungsten @ 277 Vac 198 mA @ 12 Vdc 720 VA Pilot Duty @ 120-277 Vac 250 mA @ 15 Vdc 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 10 Vdc / 11 Vac Auxiliary Contact: Notes: 3 Amp @ 30 Vac/dc max. (RIBL12BM) · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Voltage should not be applied to the coil for more than 30 seconds. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL12BM) LATCHING RELAY RIBL12SB Mechanically Latching Relay, 20 Amp SPST + True Override, 12 Vac/dc Coil, NEMA 1 Housing Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Org Line * Wht/Red 12 Vac/dc () UNLATCH Org Load * Mechanically latches and unlatches with a coil input or by manual override RIBL12SBM Mechanically Latching Relay, 20 Amp SPST + True Override, 12 Vac/dc Coil, Status LED, Auxiliary Output, NEMA 1 Housing Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Yel Line * Org Load Wht/Red 12 Vac/dc () UNLATCH * Mechanically latches and unlatches with a coil input or by manual override Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry RIBL12SB-RD · Red housing SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary: (RIBL12SBM) Contact Closed: LED On = Voltage Detected on Load Wire (RIBL12SBM) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple (RIBL12SB) 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple (RIBL12SBM) Housing Detail: See Housing A (RIBL12SB) or Housing B (RIBL12SBM) in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 182 mA @ 10 Vac 20 Amp Ballast @ 120-277 Vac 250 mA @ 12 Vac 16 Amp Electronic Ballast @ 120-277 Vac 165 mA @ 10 Vdc 5540 Watt Tungsten @ 277 Vac 198 mA @ 12 Vdc 720 VA Pilot Duty @ 120-277 Vac 250 mA @ 15 Vdc 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 10 Vdc / 11 Vac Auxiliary Contact: Notes: 3 Amp @ 30 Vac/dc max. (RIBL12SBM) · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Voltage should not be applied to the coil for more than 30 seconds. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL12SBM) (800) 888-5538 | www.functionaldevices.com 65 RELAYS LATCHING RELAYS RIBL24B Mechanically Latching Relay, 20 Amp SPST, 24 Vac/dc Coil, NEMA 1 Housing RIBL24BM Mechanically Latching Relay, 20 Amp SPST, 24 Vac/dc Coil, Status LED, Auxiliary Output, NEMA 1 Housing Wht/Blu 24 Vac/dc () LATCH Org Wht/Yel 24 Vac/dc (+) Org Wht/Red 24 Vac/dc () UNLATCH SPECIFICATIONS Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Wht/Red 24 Vac/dc () UNLATCH Yel Line Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry RIBL24B-RD · Red housing RIBL24B-N4 · NEMA 4X housing (Not available on switched models) # Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary: (RIBL24BM) Contact Closed: LED On = Voltage Detected on Load Wire (RIBL24BM) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple (RIBL24B) 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple (RIBL24BM) Housing Detail: See Housing A (RIBL24B) or Housing B (RIBL24BM) in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 175 mA @ 20 Vac 20 Amp Ballast @ 120-277 Vac 210 mA @ 24 Vac 16 Amp Electronic Ballast @ 120-277 Vac 92 mA @ 20 Vdc 5540 Watt Tungsten @ 277 Vac 110 mA @ 24 Vdc 720 VA Pilot Duty @ 120-277 Vac 138 mA @ 30 Vdc 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 20 Vdc / 22 Vac Auxiliary Contact: Notes: 3 Amp @ 30 Vac/dc max. (RIBL24BM) · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Voltage should not be applied to the coil for more than 30 seconds. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL24BM) LATCHING RELAYS RIBL24SB Mechanically Latching Relay, 20 Amp SPST + True Override, 24 Vac/dc Coil, NEMA 1 Housing Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Org Line * Wht/Red 24 Vac/dc () UNLATCH Org Load * Mechanically latches and unlatches with a coil input or by manual override RIBL24SBM Mechanically Latching Relay, 20 Amp SPST + True Override, 24 Vac/dc Coil, Status LED, Auxiliary Output, NEMA 1 Housing Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Wht/Red 24 Vac/dc () UNLATCH * Mechanically latches and unlatches with a coil input or by manual override Yel Line * Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry RIBL24SB-RD · Red housing SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary: (RIBL24SBM) Contact Closed: LED On = Voltage Detected on Load Wire (RIBL24SBM) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple (RIBL24SB) 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple (RIBL24SBM) Housing Detail: See Housing A (RIBL24SB) or Housing B (RIBL24SBM) in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 175 mA @ 20 Vac 20 Amp Ballast @ 120-277 Vac 210 mA @ 24 Vac 16 Amp Electronic Ballast @ 120-277 Vac 92 mA @ 20 Vdc 5540 Watt Tungsten @ 277 Vac 110 mA @ 24 Vdc 720 VA Pilot Duty @ 120-277 Vac 138 mA @ 30 Vdc 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 20 Vdc / 22 Vac Auxiliary Contact: Notes: 3 Amp @ 30 Vac/dc max (RIBL24SBM). · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Voltage should not be applied to the coil for more than 30 seconds. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL24SBM) 66 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® LOW-INPUT / OPTOISOLATED RELAYS RELAYS RIBTE24B RIBME2401B RIBTE02P-S Optoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from analog outputs. Product Features · Prepackaged for quick and easy installation · Extremely low current draw on the input · Control input can connect to AO for relay control · Protect controller from feedback or voltage transients High Voltage 60 Hz ac Controller Analog or Digital Out Power Supply Relay Opto Input Opto RIB® Load Low Voltage 60 Hz ac Controller 24 Vac/dc Analog or Digital Out Power Supply Relay Opto Input Opto RIB® Load ENCLOSED LOW-INPUT / OPTOISOLATED RELAYS CONTACT RATINGS MODEL # RIBTELC · RIBTELS · RIBTE24B · RIBTE01B · RIBTE02B · RIBTE24SB · RIBTE01SB · RIBTE02SB · RIBTE24P · RIBTE01P · RIBTE02P · RIBTE01P-S · RIBTE02P-S · CONTROL POWER RELAY HIGH/LOW OVERRIDE HOUSING SPEC INPUT INPUT CONTACTS RESISTIVE MOTOR PILOT DUTY SEPARATION SWITCH STYLE * PAGE 5-25 Vac/dc 10-30 Vac/dc 1 SPDT 10 A @ 120-277 Vac 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac · C 68 5-25 Vac/dc 10-30 Vac/dc 1 SPST 10 A @ 120-277 Vac 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac · 1 C 68 5-25 Vac/dc 24 Vac/dc 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · C 68 5-25 Vac/dc 120 Vac 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · C 69 5-25 Vac/dc 208-277 Vac 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · C 69 5-25 Vac/dc 24 Vac/dc 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · 1 C 70 5-25 Vac/dc 120 Vac 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · 1 C 70 5-25 Vac/dc 208-277 Vac 1 SPST 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · 1 C 71 5-25 Vac/dc 24 Vac/dc 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac 1,640 VA @ 480 Vac · C 71 5-25 Vac/dc 120 Vac 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac 1,640 VA @ 480 Vac · C 72 5-25 Vac/dc 208-277 Vac 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac 1,640 VA @ 480 Vac · C 72 5-25 Vac/dc 120 Vac 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac 1,640 VA @ 480 Vac · 1 # C 73 5-25 Vac/dc 208-277 Vac 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac 1,640 VA @ 480 Vac · 1 # C 73 TRACK MOUNT LOW-INPUT / OPTOISOLATED RELAYS CONTACT RATINGS CONTROL POWER RELAY MODEL # INPUT INPUT CONTACTS RESISTIVE RIBME2401B · 5-25 Vac/dc 24 Vac/dc/120 Vac 1 SPDT 20 A @ 277 Vac RIBME2402B · 5-25 Vac/dc 24 Vac/dc/208-277 Vac 1 SPDT 20 A @ 277 Vac MOTOR 2 HP @ 277 Vac 2 HP @ 277 Vac PILOT DUTY OVERRIDE TRACK SPEC SWITCH MOUNT ^ PAGE 1,110 VA @ 277 Vac MT4 Series 73 1,110 VA @ 277 Vac MT4 Series 73 = UL Listed - see data sheet for specific Listing * = See Housing Guide on page 201 ^ = Track mount sold separately # = Coil side relay override (requires unit to be powered) (800) 888-5538 | www.functionaldevices.com 67 RELAYS LOW COIL INPUT RELAYS RIBTELC Low Input/Optoisolated Relay, 10 Amp SPDT, 10-30 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing RIBTELS Low Input/Optoisolated Relay, 10 Amp SPST + Override, 10-30 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing 5-25 Vac/dc CONTROL INPUT 10-30 Vac/dc POWER INPUT Blu - N/C Yel - C Org - N/O 5-25 Vac/dc CONTROL INPUT 10-30 Vac/dc POWER INPUT Selectable Jumper Wire Org CLOSED Org OPEN AUTO SPECIFICATIONS Power Input: 10-30 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes (RIBTELC), No (RIBTELS) Override Switch: No (RIBTELC), Yes (RIBTELS) Contact Ratings: 10 Amp Resistive @ 120-277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) LOW COIL INPUT RELAY RIBTE24B Low Input/Optoisolated Relay, 20 Amp SPDT, 24 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing Power Input Ratings: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Normally Open or Normally Closed selected by yellow jumper wire (RIBTELS) 24 Vac/dc POWER INPUT 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - C Org - N/O SPECIFICATIONS Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) 68 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS LOW COIL INPUT RELAY RIBTE01B Low Input/Optoisolated Relay, 20 Amp SPDT, 120 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing 5-25 Vac/dc CONTROL INPUT Wht/Blk 120 Vac POWER INPUT Wht/Blk Blu - N/C Yel - C Org - N/O SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: Power Input Ratings: 20 Amp Resistive @ 277 Vac 47 mA @ 120 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) LOW COIL INPUT RELAY RIBTE02B Low Input/Optoisolated Relay, 20 Amp SPDT, 208-277 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing 5-25 Vac/dc CONTROL INPUT Wht/Brn 208-277 Vac POWER INPUT Wht/Brn Blu - N/C Yel - C Org - N/O SPECIFICATIONS Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: Power Input Ratings: 20 Amp Resistive @ 277 Vac 69 mA @ 208-277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) (800) 888-5538 | www.functionaldevices.com 69 RELAYS LOW COIL INPUT RELAY RIBTE24SB Low Input/Optoisolated Relay, 20 Amp SPST + Override, 24 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing 24 Vac/dc POWER INPUT Selectable Jumper Wire Org 5-25 Vac/dc CONTROL INPUT CLOSED Org OPEN AUTO SPECIFICATIONS Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Normally Open or Normally Closed selected by yellow jumper wire LOW COIL INPUT RELAY RIBTE01SB Low Input/Optoisolated Relay, 20 Amp SPST + Override, 120 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing Wht/Blk 120 Vac POWER INPUT Wht/Blk Selectable Jumper Wire Org 5-25 Vac/dc CONTROL INPUT CLOSED Org OPEN AUTO SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Power Input Ratings: 47 mA @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Normally Open or Normally Closed selected by yellow jumper wire 70 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS LOW COIL INPUT RELAY RIBTE02SB Low Input/Optoisolated Relay, 20 Amp SPST + Override, 208-277 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing Wht/Brn 208-277 Vac POWER INPUT Wht/Brn 5-25 Vac/dc CONTROL INPUT Selectable Jumper Wire Org CLOSED Org OPEN AUTO SPECIFICATIONS Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 69 mA @ 208-277 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Normally Open or Normally Closed selected by yellow jumper wire LOW COIL INPUT RELAY RIBTE24P Low Input/Optoisolated Relay, 20 Amp DPDT, 24 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing 24 Vac/dc POWER INPUT 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - C Org - N/O Gry - N/C Prp - C Brn - N/O SPECIFICATIONS Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Power Input Ratings: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) (800) 888-5538 | www.functionaldevices.com 71 RELAYS LOW COIL INPUT RELAY RIBTE01P Low Input/Optoisolated Relay, 20 Amp DPDT, 120 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing Wht/Blk 120 Vac POWER INPUT Wht/Blk 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - C Org - N/O Gry - N/C Prp - C Brn - N/O SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 120 Vac LOW COIL INPUT RELAY RIBTE02P Low Input/Optoisolated Relay, 20 Amp DPDT, 208-277 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Wht/Brn 208-277 Vac POWER INPUT Wht/Brn 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - C Org - N/O Gry - N/C Prp - C Brn - N/O SPECIFICATIONS Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 208-277 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) 72 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS LOW COIL INPUT RELAYS RIBTE01P-S Low Input/Optoisolated Relay, 20 Amp DPDT + Override, 120 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing RIBTE02P-S Low Input/Optoisolated Relay, 20 Amp DPDT + Override, 208-277 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing Wht/Blk 120 Vac POWER INPUT COIL ON COIL OFF AUTO Wht/Blk Blu - N/C Yel - C Org - N/O Gry - N/C Wht/Brn 208-277 Vac POWER INPUT COIL ON COIL OFF AUTO Wht/Brn Blu - N/C Yel - C Org - N/O Gry - N/C 5-25 Vac/dc CONTROL INPUT Prp - C Brn - N/O 5-25 Vac/dc CONTROL INPUT Prp - C Brn - N/O SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz (RIBTE01P-S) 208-277 Vac, 50-60 Hz (RIBTE02P-S) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes* Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Override capability is made possible by supplying constant voltage on the Power Input. No Control Input Voltage is necessary to override the relay. * Power Input Ratings: 105 mA @ 120 Vac (RIBTE01P-S) 105 mA @ 208-277 Vac (RIBTE02P-S) LOW COIL INPUT TRACK OUNT RELAYS RIBME2401B Low Input/Optoisolated Relay, 20 Amp SPDT, 24 Vac/dc/120 Vac Power Input, 5-25 Vac/dc Control Input, 4.00" Track Mount RIBME2402B Low Input/Optoisolated Relay, 20 Amp SPDT, 24 Vac/dc/208-277 Vac Power Input, 5-25 Vac/dc Control Input, 4.00" Track Mount 5-25 Vac/dc CONTROL INPUT 5-25 Vac/dc CONTROL INPUT C C Comm N/O Comm N/O 24 Vac/dc 24 Vac/dc N/C N/C POWER INPUTS POWER INPUTS 120 Vac 208-277 Vac SPECIFICATIONS Power Input: 24 Vac/dc/120 Vac, 50-60 Hz (RIBME2401B) 24 Vac/dc/208-277 Vac, 50-60 Hz (RIBME2402B) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.75"H x 4.00"W x 0.88"D1/1.38"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBME2401B) 69 mA @ 208-277 Vac (RIBME2402B) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) (800) 888-5538 | www.functionaldevices.com 73 POLARIZED / ALARM RELAYS RIB24P-FA RIBT24B-FA RELAYS RIB12S-FA RIBMN12S-FA RIB24C-FA-RD These relays are polarized to work in a supervised system and may be turned on and off by reversing polarity. These prepackaged relays make installation quick and easy and can be used in fire alarm systems, smoke control systems, etc. Product Features · Coil input is polarity sensitive · For use with fire alarm systems · System supervision for controllers that utilize end-of-line resistors · Four wire circuit ensures indication of broken wiring connection with RIB® · Prepackaged for quick and easy installation Typical Application Load Load RIB24C-FA Coil + RIB24C-FA Coil + Controller Signaling Circuit End-ofLine Resistor ENCLOSED POLARIZED / ALARM RELAYS CONTACT RATINGS MODEL # RIB12C-FA · COIL VOLTAGE 12 Vac/dc RELAY CONTACTS 1 SPDT RESISTIVE 10 A @ 277 Vac MOTOR 1 HP @ 250 Vac PILOT DUTY 770 VA @ 250 Vac HIGH/LOW OVERRIDE HOUSING SEPARATION SWITCH STYLE * A SPEC PAGE 75 RIB24C-FA · 24 Vac/dc 1 SPDT 10 A @ 277 Vac 1 HP @ 250 Vac 770 VA @ 250 Vac A 75 RIB12S-FA · 12 Vac/dc 1 SPST 10 A @ 277 Vac 1 HP @ 250 Vac 770 VA @ 250 Vac 1 A 75 RIB24S-FA · 24 Vac/dc 1 SPST 10 A @ 277 Vac 1 HP @ 250 Vac 770 VA @ 250 Vac 1 A 75 RIBT24B-FA · 24 Vac/dc 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · C 76 RIB24P-FA · 24 Vac/dc 1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac 1,640 VA @ 480 Vac B 76 TRACK MOUNT POLARIZED / ALARM RELAYS CONTACT RATINGS MODEL # RIBMN12C-FA · COIL VOLTAGE 12 Vac/dc RELAY CONTACTS 1 SPDT RESISTIVE 15 A @ 125 Vac MOTOR 1 HP @ 250 Vac PILOT DUTY 770 VA @ 250 Vac OVERRIDE SWITCH TRACK MOUNT ^ MT212 Series SPEC PAGE 77 RIBMN24C-FA · 24 Vac/dc 1 SPDT 15 A @ 125 Vac 1 HP @ 250 Vac 770 VA @ 250 Vac MT212 Series 77 RIBMN12S-FA · 12 Vac/dc 1 SPST 15 A @ 125 Vac 1 HP @ 250 Vac 770 VA @ 250 Vac 1 MT212 Series 77 RIBMN24S-FA · 24 Vac/dc 1 SPST 15 A @ 125 Vac 1 HP @ 250 Vac 770 VA @ 250 Vac 1 MT212 Series 77 = UL Listed - see data sheet for specific Listing * = See Housing Guide on page 201 ^ = Track mount sold separately 74 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® FIRE ALARM RELAYS RIB12C-FA Polarized Relay, 10 Amp SPDT, 12 Vac/dc Coil, NEMA 1 Housing RIB12S-FA Polarized Relay 10 Amp SPST-N/O + Override, 12 Vac/dc Coil, NEMA 1 Housing RELAYS 2nd Wht/Blu 12 Vac/dc 2nd Wht/Blu 12 Vac/dc Wht/Blu + Blu Wht/Blu + 12 Vac/dc N/C 12 Vac/dc Org Wht/Yel Comm 2nd Wht/Yel Comm Yel C CLOSED Org OPEN AUTO Org Wht/Yel N/O Comm 2nd Wht/Yel Comm RIB12C-FA-RD RIB12S-FA-RD · Red housing RIB12C-FA-N4 · NEMA 4X housing, UL508 only SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIB12C-FA) One (1) SPST Continuous Duty Coil (RIB12S-FA) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIB12C-FA) Yes (RIB12S-FA) FIRE ALARM RELAYS Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 36 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Order Normally Closed by adding "NC" to end of model number (RIB12S-FA) RIB24C-FA Polarized Relay, 10 Amp SPDT, 24 Vac/dc Coil, NEMA 1 Housing RIB24S-FA Polarized Relay 10 Amp SPST-N/O + Override, 24 Vac/dc Coil, NEMA 1 Housing 2nd Wht/Blu 24 Vac/dc 2nd Wht/Blu 24 Vac/dc Wht/Blu + Blu Wht/Blu + 24 Vac/dc N/C 24 Vac/dc Org Yel C Wht/Yel Comm 2nd Wht/Yel Comm Org Wht/Yel N/O Comm 2nd Wht/Yel Comm SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIB24C-FA) One (1) SPST Continuous Duty Coil (RIB24S-FA) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIB24C-FA) Yes (RIB24S-FA) CLOSED Org OPEN AUTO RIB24C-FA-RD RIB24S-FA-RD · Red housing RIB24C-FA-N4 · NEMA 4X housing, UL508 only Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Order Normally Closed by adding "NC" to end of model number (RIB12S-FA) (800) 888-5538 | www.functionaldevices.com 75 RELAYS FIRE ALARM RELAY RIBT24B-FA Polarized Relay, 20 Amp SPDT, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing Blu Comm N/C Yel C Org 24 Vac/dc + N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No FIRE ALARM RELAY RIB24P-FA Polarized Relay, 20 Amp DPDT, 24 Vac/dc Coil, NEMA 1 Housing Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 47 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 2nd Wht/Blu 24 Vac/dc Wht/Blu + 24 Vac/dc Wht/Yel Comm 2nd Wht/Yel Comm Blu - N/C Yel - C Org - N/O Gry - N/C Prp - C Brn - N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.75"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc, 15 Vdc 15 Amp Resistive @ 600 Vac 1 HP @ 120 Vac 2 HP @ 240-277 Vac 3 HP @ 480 Vac - 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 76 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS FIRE ALARM TRACK MOUNT RELAYS RIBMN12C-FA Polarized Relay, 15 Amp SPDT, 12 Vac/dc Coil, 2.75" Track Mount RIBMN12S-FA Polarized Relay, 15 Amp SPST + Override, 12 Vac/dc Coil, 2.75" Track Mount 12 Vac/dc + N/C C Comm N/O 12 Vac/dc + Comm SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN12C-FA) One (1) SPST Continuous Duty Coil (RIBMN12S-FA) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.10"H x 2.75"W x 0.75"D1/1.25"D2 (RIBMN12C-FA) 1.25"H x 2.75"W x 1.25" D1/1.25"D2 (RIBMN12S-FA) Housing Detail: See Housing H in housing guide for dimensions Origin Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN12C-FA) Yes (RIBMN12S-FA) FIRE ALARM TRACK MOUNT RELAYS AUTO C OPEN CLOSED N/O or N/C Selectable Jumpers (must cut one only) Cut for N/O Cut for N/C Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN12S-FA) RIBMN24C-FA Polarized Relay, 15 Amp SPDT, 24 Vac/dc Coil, 2.75" Track Mount RIBMN24S-FA Polarized Relay, 15 Amp SPST + Override, 24 Vac/ dc Coil, 2.75" Track Mount 24 Vac/dc + N/C 24 Vac/dc + AUTO C OPEN CLOSED C Comm N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN24C-FA) One (1) SPST Continuous Duty Coil (RIBMN24S-FA) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.10"H x 2.75"W x 0.75"D1/1.25"D2 (RIBMN24C-FA) 1.25"H x 2.75"W x 1.25" D1/1.25"D2 (RIBMN24S-FA) Housing Detail: See Housing H in housing guide for dimensions Origin Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN24C-FA) Yes (RIBMN24S-FA) N/O or N/C Selectable Jumpers (must cut one only) Cut for N/O Cut for N/C Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S-FA) (800) 888-5538 | www.functionaldevices.com 77 DRY CONTACT INPUT RELAYS RIB01SBCDC RELAYS RIB21CDC RIBM01ZNDC Product Features · Prepackaged for quick and easy installation · Provides low-voltage (Class 2) power needed to activate the relay (self-powered) by closing the dry contact input · Activated by a wide range of dry contacts such as thermostats, switches, other relays, solid-state switches, etc. · Power to energize the relay can be brought to the relay on a separate pair of wires along with the control output of the controller, or can be a local power source near the relay · Relay contacts are isolated from the input power and the dry contact input, so they can be wired to switch any other power-load or low-voltage load (see specifications for contact ratings) Typical Application Current sensing may be internal or external Load Wire Load 1 Local Power 120, 240, 277 Vac RIBX Series Current Sensor Only (Class 2) Current Sensor Status Dry Contact Input RIB® Load 2 Self-powered current switches of the RIBX Series and relays of the Dry Contact Input RIB® Series may be applied to interlock Load 2 to Load 1. ENCLOSED DRY CONTACT INPUT RELAYS MODEL # RIB21CDC · RIB01BDC · RIB02BDC · RIB01SBDC · RIB02SBDC · RIB01SBCDC · RIB02SBCDC · RIBD01BDC ~ · RIBD02BDC ~ · POWER INPUT 120-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac RELAY CONTACTS 1 SPDT 1 SPDT 1 SPDT 1 SPST 1 SPST 1 SPDT 1 SPDT 1 SPDT 1 SPDT RESISTIVE 10 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac CONTACT RATINGS MOTOR 1 HP @ 250 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac PILOT DUTY 770 VA @ 250 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac HIGH/LOW SEPARATION · · OVERRIDE SWITCH 1 1 2 2 HOUSING STYLE * A B B B B B B C C SPEC PAGE 79 79 79 80 80 80 80 81 81 TRACK MOUNT DRY CONTACT INPUT RELAYS CONTACT RATINGS MODEL # RIBM01ZNDC · POWER INPUT 120 Vac RELAY CONTACTS 1 DPDT RESISTIVE 30 A @ 300 Vac MOTOR 3 HP @ 480-600 Vac PILOT DUTY B600 OVERRIDE SWITCH TRACK SPEC MOUNT ^ PAGE MT4 Series 83 RIBM02ZNDC · 208-277 Vac 1 DPDT 30 A @ 300 Vac 3 HP @ 480-600 Vac B600 MT4 Series 83 RIBM013PNDC · 120 Vac 1 3PDT 30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase MT4 Series 83 = UL Listed - see data sheet for specific Listing = UL Component Recognized - see data sheet for specific Listing * = See Housing Guide on page 201 ^ = Track mount sold separately ~ = Time Delay 78 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS DRY CONTACT INPUT RELAYS RIB21CDC Dry Contact Relay, 10 Amp SPDT, Class 2 Dry Contact Input, 120-277 Vac Power Input, NEMA 1 Housing Org N/O Blk 120 - 277 Vac Yel Red CONTROL C Neutral or Other Phase CIRCUIT Dry Contact Input Blu N/C Wht/Blu Wht/Red RIB21CDC-RD · Red housing RIB21CDC-N4 · NEMA 4X housing, UL508 only SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac DRY CONTACT INPUT RELAYS RIB01BDC Dry Contact Relay, 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input, NEMA 1 Housing RIB02BDC Dry Contact Relay, 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input, NEMA 1 Housing Org N/O Blk 120 Vac Yel Wht CONTROL C Neutral CIRCUIT Blu N/C Dry Contact Input Wht/Red Wht/Blu Org N/O Blk 208-277 Vac Yel Red CONTROL C Neutral or Other Phase CIRCUIT Blu N/C Dry Contact Input Wht/Red Wht/Blu Power Input: 50 mA @ 240 Vac Max. Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIB01BDC) 62 mA @ 208-277 Vac (RIB02BDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. ((880000)) 888888--55553388 || wwwwww..ffuunnccttiioonnaallddeevviicceess..ccoomm 7799 RELAYS DRY CONTACT INPUT RELAYS RIB01SBDC Dry Contact Relay, 20 Amp SPST-N/O + Override, Class 2 Dry Contact Input, 120 Vac Power Input, NEMA 1 Housing RIB02SBDC Dry Contact Relay, 20 Amp SPST-N/O + Override, Class 2 Dry Contact Input, 208-277 Vac Power Input, NEMA 1 Housing Blk 120 Vac Wht Neutral CONTROL CIRCUIT CLOSED OPEN AUTO Blk 208-277 Vac Red Neutral or Other Phase CONTROL CIRCUIT CLOSED OPEN AUTO Org Org Org Org Dry Contact Input Dry Contact Input Wht/Red Wht/Red Wht/Blu Wht/Blu SPECIFICATIONS DRY CONTACT INPUT RELAY # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac DRY CONTACT INPUT RELAYS RIB01SBCDC Dry Contact Relay, 20 Amp SPDT + Override, Class 2 Dry Contact Input, 120 Vac Power Input, NEMA 1 Housing RIB02SBCDC Dry Contact Relay, 20 Amp SPDT + Override, Class 2 Dry Contact Input, 208-277 Vac Power Input, NEMA 1 Housing Blk 120 Vac Wht Neutral CONTROL CIRCUIT Blk 208-277 Vac Red Neutral or Other Phase CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu Yel C MANUAL AUTO Blu N/C Org OPEN N/O N/C N/O CLOSED CLOSED Dry Contact Input Wht/Red Wht/Blu Yel C MANUAL AUTO Blu N/C Org OPEN N/O N/C N/O CLOSED CLOSED Power Input: 42 mA @ 120 Vac (RIB01SBDC) 62 mA @ 208-277 Vac (RIB02SBDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. · Order Normally Closed by adding "-NC" to end of model number SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIB01SBCDC) 62 mA @ 208-277 Vac (RIB02SBCDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. 80 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS DRY CONTACT INPUT TRIEMLEAYDELAY RELAYS RIBD01BDC Time Delay Dry Contact Relay, 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input, NEMA 1 Housing RIBD02BDC Time Delay Dry Contact Relay, 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input, NEMA 1 Housing Org N/O Wht/Blk 120 Vac Yel Wht/Blk CONTROL C Neutral CIRCUIT Blu N/C Dry Contact Input Wht/Red Wht/Blu Org N/O Wht/Brn 208-277 Vac Yel Wht/Brn CONTROL C Neutral or Other Phase CIRCUIT Blu N/C DRY CONTACT INPUT Wht/Red Wht/Blu SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms after time delay Relay Status: Red LED On = Activated Time Delay Status: Pink LED FLASHING = Timing Timing Mode: Selectable: Delay On Make, Delay On Break, or Delay On Make and Break Timing Range: 1-30 Seconds or 1-30 Minutes Timing Adjustment: 3 pin header w/jumper for sec/min and single turn potentiometer for timing adjustment within range Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 66 mA @ 120 Vac (RIBD01BDC) 62 mA @ 208-277 Vac (RIBD02BDC) Notes: · Dry Contact Input Operation: Mode A&C: Close White/Red wire to White/Blue wire to start timing. Relay will activate after timing sequence has ended. · Mode B&C: Open White/Red and White/Blue wires to start timing. Relay will deenergize after timing sequence has ended. · If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. · Changing min/sec or mode while unit is running will reset the unit (de-energize the relay and turn off the timer). Once the dry-contact input is opened the unit will function as normal again · If the unit is powered up with the dry-contact input closed, the unit will begin timing (MODE A and MODE C) or energize the relay (MODE B). Wiring for Load on N/O Contact 120 Vac Neutral Org Switched Power to Load Yel Continuous Power Wiring for Load on N/C Contact 120 Vac Blu Switched Power to Load Neutral Yel Continuous Power MODE A: DELAY ON MAKE Dry Contact Input Closed Open Load on N/C Contact Load on N/O Contact (Not as commonly used but absolutely may be used) Time Delay Time Delay On Time Delay Time Delay O (Retriggered) On O Dry Contact Input (800) 888-5538 | www.functionaldevices.com Continued next page Closed Open 81 RELAYS Load on N/C Contact Time Delay DRY CONTACTLoLoaIdaNdoonPnNNU/O/CCTCoonnTtRtaacIcEttMLEAYDELTAimYe DeRlayELAYS - CONTINUED (Not as commonly used but MODE B: DELAYabsoOluteNly maBy bRe uEsedA) K Load on N/O Contact (Not as commonly used but absolutely may be used) Time Delay Time Delay Dry Contact Input Dry Contact Input Load on N/C Contact Time Delay Load on N/O Contact (NotLaosacdomonmoNn/lCy uCsoendtbauctt absolutely may be used) Load on N/O Contact (Not as commonly used but absolutely may be used) Time Delay MODE C: DELAY ON MAKE AND DELAY ON BREAK Dry Contact Input Time Delay Time Delay Dry Contact Input Load on N/C Contact DOM Load on N/O Contact (NoatLbaossaocdloumtoenmly oNmn/alCyy ubCseoeundstbeaudct)t DOM Load on N/O Contact (Not as commonly used but absolutely may be used) DOB DOB DOB DO(MRetriggered) DOB DOM DOB DOB (Retriggered) Time Delay Time Delay On Time Delay O (Retriggered) On Time Delay (Retriggered) O On O On O Time Delay Time Delay Time Delay (Retriggered) Time Delay (Retriggered) Closed Open Closed Open On O On O On O On O DOB DOB (Retriggered) DOB DOB (Retriggered) Closed Open Closed OpOenn O OnOn OO On O 82 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS DRY CONTACT INPUT TRREALACYK MOUNT RELAYS RIBM01ZNDC Dry Contact Relay, 30 Amp DPDT, Class 2 Dry Contact Input, 120 Vac Power Input, 4.00" Track Mount RIBM02ZNDC Dry Contact Relay, 30 Amp DPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input, 4.00" Track Mount N/C DCI Dry Contact N/O Input CONTROL CIRCUIT C DCI COM N/C POWER INPUT Neutral N/O 120 Vac C N/C DCI Dry Contact N/O Input CONTROL CIRCUIT C DCI COM N/C POWER INPUT Neutral or Other Phase N/O 208-277 Vac C SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: Red LED On = Activated Power Status: Green LED On = Activated Dimensions: 2.88"H x 4.00"W x 1.50"D1/2.00"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000" MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA @ 120 Vac 1158 VA @ 240 Vac 1109 VA @ 277 Vac 1640 VA @ 480 Vac NEMA B600 Pilot Duty DRY CONTACT INPUT TRREALACYK MOUNT RELAY RIBM013PNDC Dry Contact Relay, 30 Amp 3PDT, Class 2 Dry Contact Input, 120 Vac Power Input, 4.00" Track Mount N/C Power Input: 95 mA @ 120 Vac (RIBM01ZNDC) 95 mA @ 208-277 Vac (RIBM01ZNDC) Notes: · Dry Contact Input Operation: Close dry contact to activate relay. · If more than one dry contact input RIB shares a single dry contact input, DCI COM must be common. N/O DCI C DRY CONTACT CONTROL N/C INPUT CIRCUIT DCI COM N/O POWER INPUT C N/C Neutral 120 Vac N/O C SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Power Status: Green LED On = Activated Dimensions: 2.88"H x 4.00"W x 1.50"D1/2.00"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 30 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240/277 Vac, 1 Phase 1 HP @ 120 Vac, 1Phase 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast Heavy Pilot Duty 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1109 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase Power Input: 95 mA @ 120 Vac Notes: · Dry Contact Input Operation: Close dry contact to activate relay. · If more than one dry contact input RIB shares a single dry contact input, DCI COM must be common. (800) 888-5538 | www.functionaldevices.com 83 CURRENT SENSORS RIBMX24BF RIBX24SBA RIBHX24BA SCSCEEUUNNRRSSRREOEORRNNSSTT RIBXGTV10 RIBXKTA RIB® CURRENT SENSORS, TRANSDUCERS, AND RELAY AND SENSOR COMBOS ARE PREPACKAGED TO MAKE INSTALLATION EASY · Prepackaged: Sensor, LED indicators, and wires or terminals · Some models available with 10 Amp or 20 Amp relay · Sense up to 150 Amps · Split and solid core models · Fixed or adjustable thresholds · Hi/Low voltage separation · Transducers with voltage output or 4-20mA regulation available · Enclosed or track mount · HOA switches available · UL Listed LOW THRESHOLD CURRENT SWITCH FOR ECM APPLICATIONS ECM SENSOR VIEW VIDEO RIBXGTA-ECM 0.25 Amp Adjustable Threshold | Sense Loads up to 150 Amps | 10% Hysteresis Split Core | UL Listed | Terminals | LEDs for Line & Load Indication 84 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® CURRENT SENSORS CURRENT SENSORS SOLID AND SPLIT CORE AC SENSORS MODEL # RIBXKF RIBXKTF RIBXKA SENSING SENSOR CONTACT SWITCHING MAX. SWITCHING RANGE TYPE THRESHOLD TYPE VOLTAGE RANGE CURRENT SENSOR CONTACT TERMINATION SENSOR SPEC OUTPUT * PAGE · .25-150 A Solid Fixed, .25 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Wht/Yel 16 18 AWG Wire Leads 87 · .25-150 A Solid Fixed, .25 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire 87 · .50-150 A Solid Adjustable Solid State Switch SPST 30 Vac/dc .8 Amps Max Wht/Yel 16 18 AWG Wire Leads 87 RIBXKTA · .50-150 A Solid Adjustable Solid State Switch SPST 30 Vac/dc .8 Amps Max Terminal Strip, Accepts #14-22 AWG Wire 87 RIBXKNUTA · .20-150 A Solid Adjustable Solid State Switch SPST 30 Vac/dc 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire 87 RIBXGHF · .50-150 A Split Fixed, .50 Amp Solid State Switch SPST 120 Vac only 1 Amp Max Wht/Blk 16 18 AWG Wire Leads 87 RIBXGHTF · .50-150 A Split Fixed, .50 Amp Solid State Switch SPST 120 Vac only 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire 87 RIBXGHA · .75-150 A Split Adjustable Solid State Switch SPST 120 Vac only 1 Amp Max Wht/Blk 16 18 AWG Wire Leads 87 RIBXGHTA · .75-150 A Split Adjustable Solid State Switch SPST 120 Vac only 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire 87 RIBXGF · .35-150 A Split Fixed, .35 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Wht/Yel 16 18 AWG Wire Leads 88 RIBXGFL · .75-150 A Split Fixed, .75 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Wht/Yel 16 18 AWG Wire Leads 88 RIBXGTF · .35-150 A Split Fixed, .35 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire 88 RIBXGTFL · .75-150 A Split Fixed, .75 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire 88 RIBXGA · .75-150 A Split Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max Wht/Yel 16 18 AWG Wire Leads 88 RIBXGTA · .75-150 A Split Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire 88 RIBXGTA-ECM · .25-150 A Split Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire 88 RIBXGA-SCAL · 3-150 A Split Self-Calibrating Solid State Switch SPST 30 Vac/dc .4 Amps Max Wht/Yel 16 18 AWG Wire Leads 88 RIBXGTA-SCAL · 3-150 A Split Self-Calibrating Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire 88 RIBXGTA-NC · .75-150 A Split Adjustable Solid State Switch SPST 30 Vac/dc .1 Amps Max Terminal Strip, Accepts #14-22 AWG Wire 89 RIBXGTF-NC · .35-150 A Split Fixed, .35 Amp Solid State Switch SPST 30 Vac/dc .1 Amps Max Terminal Strip, Accepts #14-22 AWG Wire 89 RIBXG21F · .50-150 A Split Fixed, .50 Amp Solid State Switch SPST 120-277 Vac 1 Amp Max Wht/Blk 16 18 AWG Wire Leads 89 RIBXG21TF · .50-150 A Split Fixed, .50 Amp Solid State Switch SPST 120-277 Vac 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire 89 RIBXG21A · .75-150 A Split Adjustable Solid State Switch SPST 120-277 Vac 1 Amp Max Wht/Blk 16 18 AWG Wire Leads 89 RIBXG21TA · .75-150 A Split Adjustable Solid State Switch SPST 120-277 Vac 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire 89 RIBXGNTF · .35-150 A Split Fixed, .35 Amp Solid State Switch SPST 30 Vac/dc 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire 90 RIBXGNTA · .75-150 A Split Fixed, .75 Amp Solid State Switch SPST 30 Vac/dc 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire 90 RIBXGNTF-125 · .125-150 A Split Fixed, .125 Amp Solid State Switch SPST 30 Vac/dc 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire 90 RIBXKTV5-10 · 0-10 A Solid Analog Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 90 RIBXKTV5-20 · 0-20 A Solid Analog Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 90 RIBXKTV5-50 · 0-50 A Solid Analog Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 90 RIBXKTV5-100 · 0-100 A Solid Analog Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 90 RIBXK420-20 · 0-20 A Solid Analog Red & Blk 16 18 AWG Wire Leads 4-20 mA 91 RIBXK420-50 · 0-50 A Solid Analog Red & Blk 16 18 AWG Wire Leads 4-20 mA 91 RIBXK420-100 · 0-100 A Solid Analog Red & Blk 16 18 AWG Wire Leads 4-20 mA 91 RIBXGTV5-10 · 0-10 A Split Analog Terminal Strip, Accepts #14-22 AWG Wire 4-20 mA 91 RIBXGTV5 RIBXGTV10 RIBXG420-20 RIBXG420-50 RIBXG420-100 · 0-20 A, 0-50 A, 0-100 A Split · 0-20 A, 0-50 A, 0-100 A Split · 0-20 A Split · 0-50 A Split · 0-100 A Split Analog Analog Analog Analog Analog Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc 92 Terminal Strip, Accepts #14-22 AWG Wire 0-10 Vdc 92 Red & Blk 16 18 AWG Wire Leads 4-20 mA 93 Red & Blk 16 18 AWG Wire Leads 4-20 mA 93 Red & Blk 16 18 AWG Wire Leads 4-20 mA 93 RIBXGT420-RMS · 0-20 A, 0-50 A, 0-100 A Split Analog Terminal Strip, Accepts #14-22 AWG Wire 4-20 mA 94 T STYLE AC SENSORS MODEL # RIBXF RIBXA RIBXV RIBXRF RIBXRA RIBXJF RIBXJA SENSING SENSOR SWITCHING MAX. SWITCHING SENSOR CONTACT RANGE TYPE THRESHOLD CONTACT TYPE VOLTAGE RANGE CURRENT TERMINATION · .50-30 A Internal Fixed, .50 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire · .50-30 A Internal Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire · 0-30 A Internal Analog Terminal Strip, Accepts #14-22 AWG Wire · 1.25-150 A Solid Fixed, 1.25 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire · 1.25-150 A Solid Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire · 3-150 A Split Fixed, 3 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire · 3-150 A Split Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire SENSOR OUTPUT 0-5 Vdc / 0-10 Vdc SPEC PAGE 95 95 95 95 95 96 96 = UL Listed - see data sheet for specific Listing * = 4-20 mA is Loop Powered Refer to Housing Guide on page 201 or product data sheet for housing information. (800) 888-5538 | www.functionaldevices.com 85 CURRENT SENSORS CURRENT SENSOR & RELAY COMBINATIONS ENCLOSED AC SENSORS WITH RELAYS MODEL # RIBHX24BF RIBHX24BA RIBXLCF RIBXLCA RIBXLCV RIBXLCRF RIBXLCRA RIBXLCJF RIBXLCJA RIBXLCEA RIBXLCEV RIBXLSF RIBXLSA RIBXLSV RIBXLSRF RIBXLSRA RIBXLSJF RIBXLSJA RIBXLSEA RIBXLSEV RIBX24BF RIBX24BA RIBX24BV RIBX24SBF RIBX24SBA RIBX24SBV RIBX243PV RIBX243PF RIBX243PA COIL RELAY OVERRIDE VOLTAGE CONTACTS SWITCH · 24 Vac 1 SPST-N/O · 24 Vac 1 SPST-N/O · 10-30 Vac/dc 1 SPDT · 10-30 Vac/dc 1 SPDT · 10-30 Vac/dc 1 SPDT · 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc 1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT · 10-30 Vac/dc 1 SPDT · 10-30 Vac/dc 1 SPST 1 · 10-30 Vac/dc 1 SPST 1 · 10-30 Vac/dc 1 SPST 1 · 10-30 Vac/dc 1 SPST 1 · 10-30 Vac/dc 1 SPST 1 · 10-30 Vac/dc 1 SPST 1 · 10-30 Vac/dc 1 SPST 1 · 10-30 Vac/dc 1 SPST 1 · 10-30 Vac/dc 1 SPST 1 · 24 Vac/dc 1 SPDT · 24 Vac/dc 1 SPDT · 24 Vac/dc 1 SPDT · 24 Vac/dc 1 SPST 1 · 24 Vac/dc 1 SPST 1 · 24 Vac/dc 1 SPST 1 · 24 Vac/dc · 24 Vac/dc · 24 Vac/dc 1 3PST 1 3PST 1 3PST RESISTIVE 20 A @ 277 Vac 20 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 5 A @ 277 Vac 5 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 5 A @ 277 Vac 5 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 300 Vac 20 A @ 300 Vac 20 A @ 300 Vac SENSING RANGE TYPE~ THRESHOLD SENSOR CONTACT TYPE SWITCHING MAX. VOLTAGE SWITCHING SENSOR RANGE CURRENT OUTPUT SPEC PAGE .25-20 A Internal Fixed, .25 Amp Solid State Switch Contact 30 Vac/dc .1 Amps Max 97 .25-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .1 Amps Max 97 .50-10 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max 98 .50-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 98 0-10 A Internal Analog 0-5 Vdc / 0-10 Vdc 98 1.25-150 A External Fixed, 1.25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max 98 1.25-150 A External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 98 3-150 A External Fixed, 3 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max 98 3-150 A External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 98 .125 - 5 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 98 0 - 5 A Internal Analog 0-5 Vdc / 0-10 Vdc 98 .50-10 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max 99 .50-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 99 0 - 10 A Internal Analog 0-5 Vdc / 0-10 Vdc 99 1.25-150 A External Fixed, 1.25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max 99 1.25-150 A External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 99 3-150 A External Fixed, 3 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max 99 3-150 A External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 99 .125 - 5 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 99 0 - 5 A Internal Analog 0-5 Vdc / 0-10 Vdc 99 .50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max 100 .50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 100 0-20 A Internal Analog 0-5 Vdc / 0-10 Vdc 100 .50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max 100 .50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 100 0-20 A Internal Analog 0-5 Vdc / 0-10 Vdc 100 0-20 A Internal Analog 0-10 Vdc 103 .50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max 103 .50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max 104 DIN MOUNT AC SENSORS WITH RELAYS MODEL # COIL RELAY OVERRIDE SENSING VOLTAGE CONTACTS SWITCH RESISTIVE RANGE TYPE ~ THRESHOLD SENSOR CONTACT TYPE SWITCHING MAX. TRACK VOLTAGE SWITCHING NO MOUNT SPEC RANGE CURRENT SOCKET ^ PAGE RIBRXLCF-NS · 10-30 Vac/dc 1 SPST 10 A @ 277 Vac .25-10 A Internal Fixed, .25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max · DIN Rail 101 RIBRXLSA-NS RIBRXLCF RIBRXLSA · 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc 1 SPST 1 SPST 1 SPST 1 10 A @ 277 Vac .25-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max · DIN Rail 101 10 A @ 277 Vac .25-10 A Internal Fixed, .25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max DIN Rail 102 1 10 A @ 277 Vac .25-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max DIN Rail 102 TRACK MOUNT AC SENSORS WITH RELAYS MODEL # COIL RELAY OVERRIDE SENSING VOLTAGE CONTACTS SWITCH RESISTIVE RANGE TYPE ~ THRESHOLD SENSOR CONTACT TYPE SWITCHING MAX. TRACK VOLTAGE SWITCHING SENSOR MOUNT RANGE CURRENT OUTPUT ^ SPEC PAGE RIBMX24BF · 24 Vac/dc 1 SPDT 20 A @ 277 Vac .50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max MT4 Series 105 RIBMX24BA · 24 Vac/dc 1 SPDT 20 A @ 277 Vac .50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max MT4 Series 105 RIBMX24SBF · 24 Vac/dc 1 SPST 1 20 A @ 277 Vac .50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max MT4 Series 105 RIBMX24SBA · 24 Vac/dc 1 SPST 1 20 A @ 277 Vac .50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max MT4 Series 105 RIBMX24SBV · 24 Vac/dc 1 SPST 1 20 A @ 277 Vac 0-20 A Internal Analog 0-5 Vdc / 0-10 Vdc MT4 Series 105 = UL Listed - see data sheet for specific Listing ~ = Internal current sensor monitors current through common contact of relay ^ = Track mount sold separately 86 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® CURRENT AC CURRENT SWITCHES SENSOR & RELAY COMBINATIONS RIBXK Series Current Switches, Solid Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, Terminal Strip or Wire Lead Output 1.46" CURRENT SENSORS .500" Diameter Wire Clamp 1.863" 2.050" LED 2 LED 1 (if present) 1.008" 1.508" Threshold Adjust Sensor Contact Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Max Sense Voltage: 600 Vac Approvals: UL Listed, C-UL, CE, RoH, UL916, S (All models) UL864, California State Fire Marshal (RIBXKTF, RIBXKTA) Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Contact Output: Current below threshold: Open ; Current above threshold: Closed Origin: Made of US and non-US parts RIBXKA Wire Being Monitored Wht/ Yel RIBXKTF Wire Being Monitored Wht/ Yel Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp RIBXK SERIES SELECTION GUIDE Model# Sensing Range Type Threshold Sensor Contact Type Switching Voltage Range RIBXKF .25-150 Amp Solid Core Fixed, .25 Amp Solid State Switch SPST 30 Vac/dc RIBXKTF .25-150 Amp Solid Core Fixed, .25 Amp Solid State Switch SPST 30 Vac/dc RIBXKA .50-150 Amp Solid Core Adjustable Solid State Switch SPST 30 Vac/dc RIBXKTA .50-150 Amp Solid Core Adjustable Solid State Switch SPST 30 Vac/dc RIBXKNUTA .2-150 Amp Solid Core Adjustable Solid State Switch SPST 30 Vac/dc Maximum Switching Current .4 Amps Max .4 Amps Max .8 Amps Max .8 Amps Max 1 Amp Max Sensor Contact Termination LED 1 LED 2 Wht/Yel 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire Wht/Yel 16 18 AWG Wire Leads Over Trip Point Under Trip Point Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point Under Trip Point Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point Under Trip Point AC CURRENT SWITCHES RIBXGH Series Current Switches, Split Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, 120 Vac Switching Voltage, Terminal Strip or Wire Lead Output Wire Clamp 2.000" Sensor Contact RIBXGHF RIBXGHTF .52" x .52" Opening for Wire Being Monitored 2.520" LED 2 LED 1 Threshold Adjust (if present) 2.000" Wire Being Monitored Wire Being Monitored 1.100" 1.750" Removable Mounting Tab Wht/Blk Wht/Blk SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) *Temperature Derating: 1 Amp up to 50° C, 0.5 Amp up to 60° C Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open Current above threshold: Closed Origin: Made of US and non-US parts Approvals: UL Listed, UL916, C-UL, CE, RoHS Mounting/ Removable mounting tab provided. The Installation: wire clamp locks against the wire being monitored, securing the unit in place. Notes: · Use Sensor Contact to switch 120 Vac loads only. · For testing purposes, Sensor Contact will measure approximately 250 when closed and > 10 M when open. · The Sensor Contact is a Solid State Contact. RIBXGH SERIES SELECTION GUIDE Model# Sensing Range Type Threshold Sensor Contact Type Switching Voltage Range RIBXGHF .50-150 Amp Split Core Fixed, .50 Amp Solid State Switch SPST 120 Vac Only* RIBXGHTF .50-150 Amp Split Core Fixed, .50 Amp Solid State Switch SPST 120 Vac Only* RIBXGHA .75-150 Amp Split Core Adjustable Solid State Switch SPST 120 Vac Only* RIBXGHTA .75-150 Amp Split Core Adjustable Solid State Switch SPST 120 Vac Only* Maximum Switching Current 1 Amp Max 1 Amp Max 1 Amp Max 1 Amp Max Sensor Contact Termination LED 1 LED 2 Wht/Blk 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire Wht/Blk 16 18 AWG Wire Leads Over Trip Point Under Trip Point Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point Under Trip Point (800) 888-5538 | www.functionaldevices.com 87 CURRENT SENSORS AC CURRENT SWITCHES RIBXG Series Current Switches, Split Core, Fixed, Adjustable, or Self-Calibrated, Up to 150 Amps Sensing Range, Terminal Strip or Wire Lead Output Wire Clamp 2.000" Sensor Contact .52" x .52" Opening for Wire Being Monitored 2.520" LED 2 LED 1 Threshold Adjust (if present) 2.000" 1.100" 1.750" Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Max Sense Voltage: 600 Vac Approvals: UL Listed, C-UL, CE, RoHS, UL916, (All models) UL864, California State Fire Marshal (RIBXGTF, RIBXGTA, RIBXGTA-SCAL, RIBXGA-ECM) Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Contact Status: Current below threshold: Open Current above threshold: Closed Origin: Made of US and non-US parts SELF-CALIBRATING AC SWITCHES (Models with -SCAL Suffix) Sensor Contact LED 1 DIP Switch -SCAL LED TABLE LED Off No Current Two Winks Current Below Range Three Winks Current In Range Four Winks Current Above Range Continuous Winks Calibration in Progress The SCAL unit begins the 30 second self-calibration process the first time current is applied in the operating range. The threshold is then set. Subsequent calibrations may be performed by moving SW1 to the position opposite of its current position with or without current applied (hands can be safely away from live voltage). Once current begins flowing, or if it already is, the calibration process will begin. At the end of the 30 seconds, amperage will be read and set as the threshold. SW2 in the ON position provides a 15% (+/-3%) differential. In the OFF position, it provides a 25% (+/-3%) differential. SW2 can be selected at anytime and does not affect the threshold setting. Current in-range closes the sensor contact. Current above or below range opens the sensor contact. RIBXGA RIBXGTF Wire Being Monitored Wht/Yel Wht/Yel Wire Being Monitored Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp RIBXGA-SCAL RIBXGTA-SCAL Example: With a current of 10 amps set as the threshold and a 15% differential, sensor contact will be closed between 8.5 amps and 11.5 amps and open outside of this range. A small amount of hysteresis is provided to prevent dithering near the differential limits. RIBXG SERIES SELECTION GUIDE Model# Sensing Range Type Threshold Sensor Contact Type RIBXGF .35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST Switching Voltage Range 30 Vac/dc Maximum Switching Current .4 Amps Max RIBXGFL* .75-150 Amp Split Core Fixed, .75 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max RIBXGTF .35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max RIBXGTFL* .75-150 Amp Split Core Fixed, .75 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max RIBXGA .75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max RIBXGTA .75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max RIBXGA-SCAL 3-150 Amp Split Core Self-Cal. Solid State Switch SPST 30 Vac/dc .4 Amps Max RIBXGTA-SCAL 3-150 Amp Split Core Self-Cal. Solid State Switch SPST 30 Vac/dc .4 Amps Max RIBXGTA-ECM .25-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max * = Not approved by California State Fire Marshal Sensor Contact Termination Wht/Yel 16 18 AWG Wire Leads Wht/Yel 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire Wht/Yel 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire Wht/Yel 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire LED 1 Over Trip Point Over Trip Point Over Trip Point Over Trip Point See -SCAL Table See -SCAL Table LED 2 Under Trip Point Under Trip Point Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point Load Current Detcted 88 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® AC CURRENT SWITCHES RIBXG-NC Series Current Switches, Split Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, Normally Closed Terminal Strip or Wire Lead Output Wire Clamp 2.000" Sensor Contact RIBXGTF-NC .52" x .52" Opening for Wire Being Monitored 2.520" Threshold Adjust 2.000" LED 2 LED 1 (if present) 1.100" 1.750" Wire Being Monitored CURRENT SENSORS Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Contact Status: Current below threshold: Closed Current above threshold: Open Origin: Made of US and non-US parts Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), resistance 11.2 ohm RIBXG-NC SERIES SELECTION GUIDE Model# Sensing Range Type Threshold Sensor Contact Type RIBXGTF-NC .35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST Switching Voltage Range 30 Vac/dc RIBXGTA-NC .75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc Maximum Switching Current .1 Amps Max .1 Amps Max Sensor Contact Termination Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire LED 1 LED 2 Over Trip Point Under Trip Point AC CURRENT SWITCHES RIBXG21 Series Current Switches, Split Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, 120-277 Vac Switching Voltage, Terminal Strip or Wire Lead Output Wire Clamp 2.000" Sensor Contact .52" x .52" Opening for Wire Being Monitored 2.520" LED 2 LED 1 Threshold Adjust (if present) 2.000" RIBXG21F Wire Being Monitored RIBXG21TF Wire Being Monitored 1.100" 1.750" Wht/Brn Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) * Temperature Derating: 1 Amp up to 50° C, 0.5 Amp up to 60° C Max Sense Voltage: 600 Vac Sensor Contact Status: Monitored current below threshold: Open Monitored current above threshold: Closed Wht/Brn Approvals: UL Listed, UL916, C-UL, CE, RoHS Mounting/ Unit can be secured using the Installation: supplied Mounting Tab, the adjustable Wire Clamp, or both. Origin: Made of US and non-US parts Notes: · Use Sensor Contact to switch 120-277 Vac loads only. · For testing purposes, Sensor Contact will measure approximately 250 when closed and > 10 M when open. · The Sensor Contact is a Solid State Contact. RIBXG21 SERIES SELECTION GUIDE Model# Sensing Range Type Threshold Sensor Contact Type RIBXG21F .50-150 Amps AC Split Core Fixed, .50 Amp AC Solid State Switch SPST RIBXG21TF .50-150 Amps AC Split Core Fixed, .50 Amp AC Solid State Switch SPST RIBXG21A .75-150 Amps AC Split Core Adjustable Solid State Switch SPST RIBXG21TA .75-150 Amps AC Split Core Adjustable Solid State Switch SPST Switching Voltage Range 120-277 Vac 120-277 Vac 120-277 Vac 120-277 Vac Maximum Switching Current 1 Amp AC * 1 Amp AC * 1 Amp AC * 1 Amp AC * Sensor Contact Termination LED 1 LED 2 Wht/Blk 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire Wht/Blk 16 18 AWG Wire Leads Over Threshold Under Threshold Terminal Strip, Accepts #14-22 AWG Wire Over Threshold Under Threshold (800) 888-5538 | www.functionaldevices.com 89 CURRENT SENSORS AC CURRENT SWITCHES RIBXGN Series Current Switches, Split Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, 1 Amps Switching Current, Terminal Strip Output Wire Clamp RIBXGNTF 2.000" Sensor Contact .52" x .52" Opening for Wire Being Monitored 2.520" LED 2 LED 1 Threshold Adjust (if present) 2.000" 1.100" 1.750" Wire Being Monitored Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Contact Status: Current below threshold: Open Current above threshold: Closed Origin: Made of US and non-US parts Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), resistance 0.26 ohm RIBXGN SERIES SELECTION GUIDE Model# Sensing Range Type Threshold Sensor Contact Type RIBXGNTF .35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST Switching Voltage Range 30 Vac/dc Maximum Switching Current 1 Amps Max RIBXGNTA .75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc 1 Amps Max RIBXGNTF-125 .125-150 Amp Split Core Fixed, .125 Amp Solid State Switch SPST 30 Vac/dc 1 Amps Max Sensor Contact Termination Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire LED 1 Over Trip Point LED 2 Under Trip Point AC TRANSDUCERS RIBXKTV Series Current Transducers, Solid Core, Up to 100 Amps Sensing Range, 0-5 Vdc Terminal Strip Sensor Output 1.460" .500" Diameter 1.863" 2.050" 1.008" + 2.050" Wire Clamp Removable Mounting Tab Output: Terminal Strip Accepts 14-22 AWG wire SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 96.8% Full Scale Loading: RIBXKTV5-10, 1% Error @ 180 k RIBXKTV5-20, 1% Error @ 90 k RIBXKTV5-50, 1% Error @ 40 k RIBXKTV5-100, 1% Error @ 15 k Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Type: Solid core with voltage output Origin: Made of US and non-US parts RIBXKTV SERIES SELECTION GUIDE Model# Sensing Range Sensor Output RIBXKTV5-10 0-10 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) RIBXKTV5-20 0-20 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) RIBXKTV5-50 0-50 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) RIBXKTV5-100 0-100 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) 90 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® AC TRANSDUCERS RIBXK420 Series Current Transducers, Solid Core, Up to 100 Amps Sensing Range, 4-20 mA Wire Lead Sensor Output 1.460" CURRENT SENSORS .500" Diameter 1.863" Black () Red (+) 1.008" 2.050" Wire Clamp Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Wires: Red (positive) & Black (negative), 16, 18 AWG, 600V Rated Sensor Type: Internal, with 4-20 mA Transmitter Output Sensor Range: 0-20 Amps, 0-50 Amps, or 0-100 Amps (See Selection Guide Below) Accuracy: 96.4% FS Linearity: 99% FS (25%-100% Span) Max Output Current: 30 mA Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Origin: Made of US and non-US parts RIBXK420 SERIES SELECTION GUIDE Model# Sensing Range Sensor Output RIBXK420-20 0-20 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) RIBXK420-50 0-50 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) RIBXK420-100 0-100 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) AC TRANSDUCERS RIBXGTV5-10 Current Transducer, Split Core, 0-10 Amp, 0-5 Vdc Terminal Output Wire Clamp Output Load Resistance - + Supply Voltage -+ RIBXK420 Red + Black - OUTPUT LOAD RESISTANCE Maximum 700 ohms 600 ohms 500 ohms 400 ohms 300 ohms 250 ohms 200 ohms 100 ohms 50 ohms SUPPLY VOLTAGE Minimum Maximum 26 Vdc 24 Vdc 21 Vdc 19 Vdc 17 Vdc 16 Vdc 14 Vdc 12 Vdc 11 Vdc 35 Vdc 35 Vdc 35 Vdc 30 Vdc 30 Vdc 28 Vdc 28 Vdc 28 Vdc 28 Vdc 2.000" .52" x .52" Opening for Wire Being Monitored 2.520" 1.100" 1.750" 2.000" Output: Terminal Strip Accepts 14-22 AWG wire Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 98.3% Full Scale Loading: 5% Error @ 58 k Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Type: Split core with voltage output Origin: Made of US and non-US parts Output Voltage (Vdc) 5 4 3 2 1 0 0 2 4 6 8 10 Input Current (A) Idea l Actual (800) 888-5538 | www.functionaldevices.com 91 CURRENT SENSORS AC TRANSDUCER RIBXGTV5 Current Transducer, Split Core, Multi-Range (0-20 Amp, 50 Amp, 100 Amp), 0-5 Vdc Terminal Output Wire Clamp 2.000" .52" x .52" Opening for Wire Being Monitored 2.520" 1.100" 1.750" Removable Mounting Tab 2.000" Output: Terminal Strip Accepts 14-22 AWG wire DIP Switches DIP SWITCH 1 2 Sensing Range OFF OFF 0-20 Amp OFF ON 0-50 Amp ON OFF 0-100 Amp SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 98.3% Full Scale Loading: RIBXGTV5, (0-20 Amp), 5% Error @ 33 k RIBXGTV5, (0-50 Amp), 5% Error @ 15 k RIBXGTV5, (0-100 Amp), 5% Error @ 6.8 k Max Sense Voltage: 600 Vac Origin: Made of US and non-US parts Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Type: Split core with voltage output AC TRANSDUCER RIBXGTV10 Current Transducer, Split Core, Multi-Range (0-20 Amp, 50 Amp, 100 Amp), 0-10 Vdc Terminal Output Wire Clamp 2.000" .52" x .52" Opening for Wire Being Monitored 2.520" 1.100" 1.750" 2.000" Output: Terminal Strip Accepts 14-22 AWG wire DIP Switches DIP SWITCH 1 2 Sensing Range OFF OFF OFF ON ON OFF 0-20 Amp 0-50 Amp 0-100 Amp Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 98.8% Full Scale Loading: RIBXGTV10, (0-20 Amp), 5% Error @ 60.4 k RIBXGTV10, (0-50 Amp), 5% Error @ 25.24 k RIBXGTV10, (0-100 Amp), 5% Error @ 13.65 k Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Type: Split core with voltage output Origin: Made of US and non-US parts 92 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® Output (mA) CURRENT SENSORS AC TRANSDUCERS RIBXG420 Series Current Transducers, Split Core, Up to 100 Amps Sensing Range, 4-20 mA Wire Lead Sensor Output Wire Clamp 2.520" 2.000" 1.100" 1.750" .52" x .52" Opening for Wire Being Monitored 2.520" Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Wires: Red (positive) & Black (negative), 16, 18 AWG, 600V Rated Sensor Type: Internal, with 4-20 mA Transmitter Output Sensor Range: 0-20 Amps, 0-50 Amps, or 0-100 Amps (See Selection Guide Below) Accuracy: Refer to chart below. Linearity: 99% FS (20%-100% Span) Max Output Current: 30 mA Max Sense Voltage: 600 Vac Approvals: UL Listed, UL508, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Origin: Made of US and non-US parts OUTPUT LOAD RESISTANCE Maximum 800 ohms 500 ohms 350 ohms 250 ohms 200 ohms 100 ohms 50 ohms SUPPLY VOLTAGE Minimum 24 Vdc 18 Vdc 15 Vdc 13 Vdc 12 Vdc 10 Vdc 9 Vdc Maximum 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc RIBXG420 SERIES SELECTION GUIDE Model# Sensing Range Sensor Output RIBXG420-20 0-20 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) RIBXG420-50 0-50 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) RIBXG420-100 0-100 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) Span 20% 100% 99% 99% 99% ACCURACY Span 10% 100% 99% 97.5% 97% Span 0% 100% 95% 92% 91% RIBXG420-20 20 IDEAL ACTUAL Output Load Resistance - + Supply Voltage -+ RIBXG420 Red + Black - 16 8 7.5 12 7 6.5 8 6 5.5 4 5 0 4 8 12 16 20 4.5 Current (A) 4 0 1 2 3 4 (800) 888-5538 | www.functionaldevices.com 93 CURRENT SENSORS AC TRANSDUCER RIBXGT420-RMS VFD Compatible True RMS Current Transducer, Split Core, Multi-Range (0-10, 20, and 50A), 4-20 mA Terminal Output Wire Clamp 2.520" 2.000" 1.100" 1.750" .52" x .52" Opening for Wire Being Monitored 2.520" Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Sensor Type: Internal, with 4-20 mA Transmitter Output Sensor Range: 0-10 Amps, 0-20 Amps, or 0-50 Amps (See Selection Guide Below) Accuracy: ± 2% FS (5% - 100% Span) Max Sense Voltage: 600 Vac Frequency: 10-400 Hz Approvals: UL Listed, UL508, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. OUTPUT LOAD RESISTANCE Maximum 800 ohms 500 ohms 350 ohms 250 ohms 200 ohms 100 ohms 50 ohms SUPPLY VOLTAGE Minimum 24 Vdc 18 Vdc 15 Vdc 13 Vdc 12 Vdc 10 Vdc 9 Vdc Maximum 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc True RMS: True RMS current transducers can measure the current of waveforms that are not purely sinusoidal. This enables them to be used in applications involving VFDs, phase angle dimmers, switching power supplies and more. DIP Switch 1 OFF OFF ON DIP Switch 2 OFF ON OFF Sensing Range 0-10A 0-20A 0-50A IDEAL ACTUAL Output Load Resistance - + Supply Voltage -+ RIBXGT420-RMS + - 94 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® AC CURRENT SWITCHES RIBXF Current Switch, Fixed, 0.50-30 Amp, NEMA 1 Housing RIBXA Current Switch, Adjustable, 0.50-30 Amp, NEMA 1 Housing Sensor Feedback Current Sensor Status Not Used Current Sensor Circuitry Prp Prp Sensor Feedback Current Sensor Status Not Used Current Sensor Circuitry Prp Prp SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: Internal, with contact status Sensor Threshold: Fixed, .5 Amps (RIBXF); Adjustable, .50-30 Amps (RIBXA) Sensor Range: .50-30 Amps Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open / LED OFF Current above threshold: Closed / LED ON Sensor Contact: · Solid State Contact · When sensor contact is on (closed), · 30 Vac/dc, .4 Amp Max. voltage drop < .3 Vac/dc @ .1 Amp · When sensor contact is off < 1.6 Vac/dc @ .4 Amp (open), leakage <30 uA @ 30Vac/dc AC TRANSDUCER RIBXV Current Transducer, 0-30 Amp, Analog, 0-5 Vdc/0-10 Vdc Output, NEMA 1 Housing Current Sensor Circuitry Prp Prp V V 0-10 Vdc 0-5 Vdc Com SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: Internal, with voltage output Sensor Range: 0-30 Amps Max Sense Voltage: 600 Vac Sensor Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 3% full scale · Vripple < 10m Vac AC CURRENT SWITCHES RIBXRF Current Switch, Solid Remote, Fixed, 1.25-150 Amp RIBXRA Current Switch, Solid Remote, Adjustable, 1.25-150 Amp Sensor Contact Current Sensor Circuitry AXKT CT Gry Gry Wire Being Monitored SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: External, with contact status Sensor Threshold: Fixed, 1.25 Amps (RIBXRF) Adjustable, 1.25-150 Amps (RIBXRA) Sensor Range: 1.25-150 Amps Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open / LED OFF Current above threshold: Closed / LED ON Sensor Contact: · Solid State Contact · When sensor contact is on (closed), · 30 Vac/dc, .4 Amp Max. voltage drop < .3 Vac/dc @ .1 Amp · When sensor contact is off < 1.6 Vac/dc @ .4 Amp (open), leakage <30 uA @ 30Vac/dc (800) 888-5538 | www.functionaldevices.com 95 CURRENT SENSORS CURRENT SENSORS AC CURRENT SWITCH RIBXJF Current Switch, Split Ring Remote, Fixed, 3-150 Amp Sensor Contact Current Sensor Gry Circuitry Gry Wire Being Monitored AXGT CT SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Remote Dimensions: (Outside) 2.52 x 2.00, (Inside) .52 x .52 Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: External, with contact status Sensor Threshold: Fixed, 3 Amps Sensor Range: 3-150 Amps Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open / LED OFF Current above threshold: Closed / LED ON Sensor Contact: · Solid State Contact · When sensor contact is on (closed), · 30 Vac/dc, .4 Amp Max. voltage drop < .3 Vac/dc @ .1 Amp · When sensor contact is off < 1.6 Vac/dc @ .4 Amp (open), leakage <30 uA @ 30Vac/dc AC CURRENT SWITCH RIBXJA Current Switch, Split Ring Remote, Adjustable, 3-150 Amp Sensor Contact Current Sensor Gry Circuitry Gry Wire Being Monitored AXGT CT SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS UL Accepted for Use in Plenum, NEMA 1 Housing Rating: External, with contact status Sensor Type: Adjustable, 3-150 Amps Sensor Threshold: 3-150 Amps Sensor Range: 600 Vac Max Sense Voltage: Current below threshold: Open / LED OFF Sensor Contact Status: Current above threshold: Closed / LED ON Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp 96 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAY & AC CURRENT SWITCH COMBO RIBHX24BF Current Switch and Relay Combination, 20 Amp SPST-N/O, Fixed, 24 Vac/dc Coil, NEMA 1 Housing Gry Sensor Feedback Current Sensor Status Gry Wht/Yel 24 Vac/dc Wht/Yel Org - C Org - N/O RIBHX24BF-RD · Red housing RIBHX24BF-N4 · NEMA 4X housing, UL508 only CURRENT SENSORS SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Current Sensor Status Pink LED On = Current Over Trip Point (0.25 Amp) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Coil Current: 128 mA @ 24 Vac 71 mA @ 30 Vdc Sensor Type: Internal, with contact status Sensor Threshold: Fixed, .25 Amp Sensor Range: .25-20 Amps Sensor Feedback Output: Solid State Contact 30 Vac/dc, 100 mA Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac Pull In = 18 Vac RELAY & AC CURRENT SWITCH COMBO RIBHX24BA Current Switch and Relay Combination, 20 Amp SPST-N/O, Adjustable, 24 Vac/dc Coil, NEMA 1 Housing Gry Sensor Feedback Current Sensor Status Gry RIBHX24BA-RD · Red housing Wht/Yel 24 Vac/dc Wht/Yel Org - C Org - N/O SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red or Green LED On = Activated Current Sensor Status Green LED On = Current Over Trip Point Adjustable Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Contact Ratings: Sensor Contact: 20 Amp Resistive @ 277 Vac · When current sensor status is off (open), leakage 20 Amp Ballast @ 277 Vac <30 uA @ 30Vac/dc 16 Amp Electronic Ballast @ 277 Vac (N/O) · When current sensor status is on (closed), voltage drop 10 Amp Tungsten @ 120 Vac (N/O) < .3 Vac/dc @ .1 Amp 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac Coil Current: 1 HP @ 120 Vac 128 mA @ 24 Vac 71 mA @ 30 Vdc Sensor Type: Internal, with contact status Sensor Threshold: Adjustable Coil Voltage Input: Sensor Range: .25-20 Amps 24 Vac ; 50-60 Hz Sensor Feedback Output: Solid State Contact 30 Vac/dc, 100 mA Drop Out = 3 Vac Pull In = 18 Vac (800) 888-5538 | www.functionaldevices.com 97 CURRENT SENSORS RELAY & AC CURRENT SWITCH COMBOS RIBXLC Series Current Switches or Transducers with Relay, 5 or 10 Amp SPDT, 10-30 Vac/dc Coil, Fixed, Adjustable, or Analog, Up to 150 Amps Sensing Range, Terminal Strip or Wire Lead Output RIBXLCA, RIBXLCF, RIBXLCEA+ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Blu - N/C Yel - C Org - N/O RIBXLCV, RIBXLCEV^ 10-30 Vac/dc Comm V V 0-10 Vdc 0-5 Vdc Com Blu - N/C Yel - C Org - N/O RIBXLCRA, RIBXLCRF+ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Current Sensor Circuitry Blu - N/C Yel - C Org - N/O Wire Being Monitored AXKT CT Gry Gry RIBXLCJA, RIBXLCJF+ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Current Sensor Circuitry Blu - N/C Yel - C Org - N/O Wire Being Monitored AXGT CT Gry Gry RIBXLCA SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS UL Accepted for Use in Plenum, NEMA 1 Housing Rating: Yes Gold Flash: No Override Switch: Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc + Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp ^ Sensor Feedback Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 3% full scale · Vripple < 10m Vac Notes: · Models AXKT and AXGT CT remotes do not have contact closure circuitry and only work in conjunction with RIBXLCR and RIBXLCJ models, respectively. RIBXLC SERIES SELECTION GUIDE Model# Sensing Range Type * Threshold Sensor Output Remote Style RIBXLCF ECMS .50-10 Amps Internal w/ contact status Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp RIBXLCA ECMS .50-10 Amps Internal w/ contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp RIBXLCV 0-10 Amps Internal w/ voltage output Analog 0-5 Vdc 0-10 Vdc RIBXLCRF ECMS1.25-150 Amps External w/ contact status Fixed, 1.25 Amp Solid State Contact Model AXKT: (Solid 30 Vac/dc, 0.4 Amp Core Remote CT) RIBXLCRA ECMS1.25-150 Amps External w/ contact status Adjustable Solid State Contact Model AXKT: (Solid 30 Vac/dc, 0.4 Amp Core Remote CT) RIBXLCJF ECMS 3-150 Amps External w/ contact status Fixed, 3 Amp Solid State Contact Model AXGT: (Split 30 Vac/dc, 0.4 Amp Core Remote CT) RIBXLCJA ECMS 3-150 Amps External w/ contact status Adjustable Solid State Contact Model AXGT: (Split 30 Vac/dc, 0.4 Amp Core Remote CT) RIBXLCEA .125-5 Amps Internal w/ contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp RIBXLCEV 0-5 Amps Internal w/ voltage output Analog 0-5 Vdc 0-10 Vdc * = Internal current sensor monitors current through common contact of relay. Resistive 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp 5 Amp 5 Amp Contact Ratings 10 Amp Resistive @ 120-277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) 5 Amp Resistive @ 277 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 268 VA Pilot Duty @ 277 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 175 VA Pilot Duty @ 277 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) 98 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® CURRENT SENSORS RELAY & AC CURRENT SWITCH COMBOS RIBXLS Series Current Switches or Transducers with Relay, 5 or 10 Amp SPST + Override, 10-30 Vac/dc Coil, Fixed, Adjustable, or Analog, Up to 150 Amps Sensing Range, Terminal Strip or Wire Lead Output RIBXLSA, RIBXLSF, (RIBXLSEA*)+ RIBXLSV, (RIBXLSEV*)^ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Selectable Jumper Wire Org* CLOSED OPEN AUTO Org* *Org wires will be Gry 10-30 Vac/dc Comm V V 0-10 Vdc 0-5 Vdc Com Selectable Jumper Wire Org* CLOSED OPEN AUTO Org* *Org wires will be Gry RIBXLSRA, RIBXLSRF+ Sensor Feedback Current Sensor Status 10-30 Vac/dc Current Sensor Circuitry Selectable Jumper Wire Org Comm CLOSED Org OPEN AUTO Wire Being Monitored AXKT CT Gry Gry RIBXLSJA, RIBXLSJF+ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Current Sensor Circuitry Selectable Jumper Wire Org CLOSED Org OPEN AUTO Wire Being Monitored AXGT CT Gry Gry RIBXLSA SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc + Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp ^ Sensor Feedback Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 3% full scale · Vripple < 10m Vac Notes: · Normally Open or Normally Closed selected by yellow jumper wire · Models AXKT and AXGT CT remotes do not have contact closure circuitry and only work in conjunction with RIBXLSR and RIBXLSJ models, respectively. RIBXLS SERIES SELECTION GUIDE Model# Sensing Range Type * Threshold Sensor Output Remote Style RIBXLSF ECMS .50-10 Amps Internal w/ contact status Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp RIBXLSA ECMS .50-10 Amps Internal w/ contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp RIBXLSV 0-10 Amps Internal w/ voltage output RIBXLSRF ECMS 1.25-150 Amps External w/ contact status RIBXLSRA ECMS 1.25-150 Amps External w/ contact status Analog Fixed, 1.25 Amp Adjustable 0-5 Vdc 0-10 Vdc Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Model AXKT: (Solid Core Remote) Model AXKT: (Solid Core Remote) RIBXLSJF ECMS 3-150 Amps External w/ contact status Fixed, 3 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Model AXGT: (Split Core Remote) RIBXLSJA ECMS 3-150 Amps External w/ contact status Adjustable Solid State Contact Model AXGT: (Split 30 Vac/dc, 0.4 Amp Core Remote) RIBXLSEA .125-5 Amps Internal w/ contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp RIBXLSEV 0-5 Amps Internal w/ voltage output Analog 0-5 Vdc 0-10 Vdc * = Internal current sensor monitors current through common contact of relay. Resistive 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp Contact Ratings 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) 10 Amp 10 Amp 5 Amp 5 Amp 5 Amp Resistive @ 277 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 268 VA Pilot Duty @ 277 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 175 VA Pilot Duty @ 277 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) (800) 888-5538 | www.functionaldevices.com 99 CURRENT SENSORS RELAY & AC CURRENT SWITCH COMBOS RIBX24 Series Current Switches or Transducers with Relay, 20 Amp SPDT or SPST + Override, 24 Vac/dc Coil, Fixed, Adjustable, or Analog, Up to 150 Amps Sensing Range, Terminal Strip or Wire Lead Output RIBX24BA, RIBX24BF+ RIBX24BV^ Sensor Feedback Current Sensor Status 24 Vac/dc Comm Blu - N/C Yel - C Org - N/O RIBX24SBA, RIBX24SBF+ Sensor Feedback Current Sensor Status 24 Vac/dc Comm Selectable Jumper Wire Org CLOSED Org OPEN AUTO 24 Vac/dc Comm RIBX24SBV^ 24 Vac/dc Comm V V V V 0-10 Vdc 0-5 Vdc Com Blu - N/C Yel - C Org - N/O 0-10 Vdc 0-5 Vdc Com Selectable Jumper Wire Org CLOSED Org OPEN AUTO SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc RIBX24SBA Sensor Contact: + · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Sensor Feedback Output: ^ · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 1% full scale · Vripple < 10m Vac RIBX24 SERIES SELECTION GUIDE Model# Sensing Range Type * Threshold Sensor Output Resistive RIBX24BF ECMS .50-20 Amps Internal w/ contact status Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp 20 Amp RIBX24BA ECMS .50-20 Amps Internal w/ contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp 20 Amp RIBX24BV 0-20 Amps Internal w/ voltage output Analog 0-5 Vdc 0-10 Vdc 20 Amp RIBX24SBF ECMS .50-20 Amps Internal w/ contact status Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp 20 Amp RIBX24SBA ECMS .50-20 Amps Internal w/ contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp 20 Amp RIBX24SBV 0-20 Amps Internal w/ voltage output Analog 0-5 Vdc 0-10 Vdc 20 Amp Override Switch No No No Yes Yes Yes Contact Ratings Notes 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac · Normally Open or Normally Closed selected by yellow jumper wire * = Internal current sensor monitors current through common contact of relay. 100 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® DIN MOUNT NO SOCKET RELAY & AC CURRENT SWITCH COMBO RIBRXLCF-NS Current Switch and Relay Combination, 10 Amp SPST-N/O, 10-30 Vac/dc Coil, Fixed, 0.25-10 Amp, No Socket Non-Pluggable Relay C NO CURRENT SENSORS 10-30 Vac/dc Sensor Feedback Current Sensor Status N/O Current Status Relay LED Pink Current Status ADIN35ES Pair of End Stops for 35mm DIN Rail 10-30V COM Comm C SPECIFICATIONS Open Lid this Side ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information. # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Sensing Range: .25 - 10A Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac 1/3 HP @ 120-240 Vac 1/4 HP @ 277 Vac Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Sensor Contact: Solid State Contact 30Vac/dc, 0.1A Max. · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp DIN MOUNT NO SOCKET RELAY & AC CURRENT SWITCH COMBO RIBRXLSA-NS Current Switch and Relay Combination, 10 Amp SPST-N/O + Coil Side Override, 10-30 Vac/dc Coil, Fixed, 0.25-10 Amp, No Socket Non-Pluggable Relay PWR Closed CTRL Open Auto Sensor Feedback Current Sensor Status N/O PWR CTRL COM CLOSED OPEN AUTO Override Switch Current Status Relay LED Pink Current Status Apply Continuous Power(10-30Vac/dc) to PWR and COM. C NO ADJ. CURR STAT ADIN35ES Pair of End Stops for 35mm DIN Rail Comm C SPECIFICATIONS Apply Coil Control(10-30Vac/dc) to CTRL and COM. ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information. # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Sensing Range: .25 - 10A Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac 1/3 HP @ 120-240 Vac 1/4 HP @ 277 Vac Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Sensor Contact: Solid State Contact 30Vac/dc, 0.1A Max. · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp (800) 888-5538 | www.functionaldevices.com 101 DIN MOUNT RELAY & AC CURRENT SWITCH COMBO RIBRXLCF Current Switch and Relay Combination, 10 Amp SPST-N/O, 10-30 Vac/dc Coil, Fixed, 0.25-10 Amp CURRENT SENSORS C NO 10-30 Vac/dc Sensor Feedback Current Sensor Status N/O Current Status Relay LED Pink Current Status ADIN35ES Pair of End Stops for 35mm DIN Rail 10-30V COM Comm C SPECIFICATIONS Open Lid this Side ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information. # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Sensing Range: .25 - 10A Replacement Relay: ARL1C Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac 1/3 HP @ 120-240 Vac 1/4 HP @ 277 Vac Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Sensor Contact: Solid State Contact 30Vac/dc, 0.1A Max. · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp DIN MOUNT RELAY & AC CURRENT SWITCH COMBO RIBRXLSA Current Switch and Relay Combination, 10 Amp SPST-N/O + Coil Side Override, 10-30 Vac/dc Coil, Adjustable, 0.25-10 Amp PWR Closed CTRL Open Auto Comm Sensor Feedback Current Sensor Status N/O C PWR CTRL COM CLOSED OPEN AUTO Override Switch Current Status Relay LED Pink Current Status Open Lid this Side Apply Continuous Power(10-30Vac/dc) to PWR and COM. Apply Coil Control(10-30Vac/dc) to CTRL and COM. SPECIFICATIONS C NO ADJ. CURR STAT ADIN35ES Pair of End Stops for 35mm DIN Rail ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information. # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Sensing Range: .25 - 10A Replacement Relay: ARL1C Accessories: ADIN35, ADIN35ES Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac 1/3 HP @ 120-240 Vac 1/4 HP @ 277 Vac Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Sensor Contact: Solid State Contact 30Vac/dc, 0.1A Max. · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp 102 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAY & AC CURRENT SWITCH COMBO RIBX243PV Transducer and Relay Combination, 20 Amp 3PST-N/O, 24 Vac/dc Coil, Analog, 0-20 Amp, 0-10 Vdc Output, NEMA 1 Housing Blu - N/O Blu - N/O Yel - N/O Yel - N/O CURRENT SENSORS V 24 Vac/dc Comm Com 0-10 Vdc Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase RELAY & AC CURRENT SWITCH COMBO RIBX243PF Current Switch and Relay Combination, 20 Amp 3PST-N/O, 24Vac/dc Coil, Internal Fixed, 0.5-20 Amp, NEMA 1 Housing Blu - N/O Blu - N/O Sensor Type: Internal, with voltage output. Current sensing on orange wires Sensor Range: 0-20 Amps Sensor Feedback Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 1% full scale · Vripple < 10m Vac Notes: · Order Normally Closed by adding "-NC" to end of model number · Can be ordered with 0-5 Vdc voltage output Consult factory. Yel - N/O Yel - N/O 24 Vac/dc Comm Sensor Feedback Current Sensor Status (Orange WIres) Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Sensor Type: Internal, with contact status Current sensing on orange wires Sensor Threshold: Fixed, .5 Amps Sensor Range: .50-20 Amps Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Notes: · Order Normally Closed by adding "-NC" to end of model number (800) 888-5538 | www.functionaldevices.com 103 CURRENT SENSORS RELAY & AC CURRENT SWITCH COMBO RIBX243PA Current Switch and Relay Combination, 20 Amp 3PST-N/O, 24Vac/dc Coil, Internal Adjustable, 0.5-20 Amp, NEMA 1 Housing Blu - N/O Blu - N/O Yel - N/O Yel - N/O 24 Vac/dc Comm Sensor Feedback Current Sensor Status (Orange WIres) Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Sensor Type: Internal, with contact status Current sensing on orange wires Sensor Threshold: Adjustable, .50-20 Amps Sensor Range: .50-20 Amps Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Notes: · Order Normally Closed by adding "-NC" to end of model number 104 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® CURRENT SENSORS RELAY & AC CURRENT SWITCH COMBOS RIBMX24 Series Current Switches or Transducers with Relay, 20 Amp SPDT or SPST + Override, 24 Vac/dc Coil, Fixed, Adjustable, or Analog, Up to 150 Amps Sensing Range, Terminal Strip, 4.00" Track Mount RIBMX24BA, RIBMX24BF+ RIBMX24SBV^ Sensor Feedback Current Sensor Status C 24 Vac/dc N/O Comm N/C 0-10 Vdc V 0-5 Vdc V Comm 24 Vac/dc Comm Selectable Jumper Wire Not Used CLOSED OPEN AUTO RIBMX24SBA, RIBMX24SBF+ Sensor Feedback Current Sensor Status 24 Vac/dc Comm Selectable Jumper Wire Not Used CLOSED OPEN AUTO SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: Red LED On = Activated Dimensions: 2.95"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000, MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Sensor Contact: + · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Sensor Feedback Output: ^ · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 1% full scale · Vripple < 10m Vac RIBMX24 SERIES SELECTION GUIDE Model# Sensing Range RIBMX24BF ECMS .50-20 Amps RIBMX24BA ECMS .50-20 Amps Type* Internal w/ contact status Internal w/ contact status Threshold Sensor Output Resistive Override Switch Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp 20 Amp No Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp 20 Amp No Contact Type SPDT SPDT Contact Ratings 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Notes RIBMX24SBF ECMS .50-20 Amps Internal w/ contact status Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp 20 Amp Yes RIBMX24SBA ECMS .50-20 Amps Internal w/ contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp 20 Amp Yes RIBMX24SBV Internal w/ 0-20 Amps voltage output Analog 0-5 Vdc 0-10 Vdc 20 Amp Yes * = Internal current sensor monitors current through common contact of Relay SPST SPST SPST 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac · Normally Open or Normally Closed selected by yellow jumper wire (800) 888-5538 | www.functionaldevices.com 105 AC & DC POWER SUPPLIES POWER SUPPLIES PSH100A100AB10 PSH300A-LVC PSH40AB10 PSM19A24DAS PSMN40A24DS PSP24DA AC & DC POWER SUPPLIES · 40 - 500 VA AC models · Single & dual transformers · Prepackaged power supply kits · Class 2 models · On/off control · Overcurrent protection · LED power indicator · High/low voltage separation · 120 Vac convenience outlets 500, 300 & 200 VA Power Supplies are Perfect for VAV & Zone and Network Controller Applications · 5 or 3 isolated 100 VA or 5 isolated 40 VA outputs · On/Off circuit breaker switch for each output · UL Listed Class 2 · Enclosed or sub-panel mount · Low voltage compartment models available · 120 Vac convenience outlet available Mounting Your Controller and Peripheral Devices is Easy and Convenient in our Prepackaged Power Supply Solutions Metal Enclosure, Power Supply, and Sub-Panel with Several Options to Fit Your Needs If you plan to install a controller and other peripheral devices, an important consideration is where the items will be placed within an enclosure and how they will be powered. We have a line of products that can address both of those needs: the MHP Series. These products include a metal enclosure, power supply and a sub-panel with several prepackaged options to meet your specific needs. 106 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER SUPPLIES AC POWER SUPPLIES AC POWER SUPPLIES: 40-100 VA MODEL # PSB40AB10 TRANSFORMER(S) · 40 VA INPUT POWER 120 Vac AUX 120 VAC OUTPUT MAIN BREAKER ON SECONDARY EXTENSION HOUSING STYLE / SPEC HEIGHT WIDTH DEPTH OUTLETS WIRE INPUT POWER * CONFIGURATION CORD TRACK MOUNT PAGE 5.200 5.250 3.750 · · 10 A Switch/Breaker Ext. Terminal Strip Panel Mount 109 PSB100AB10 PSC40AB10 · 100 VA · 40 VA 120 Vac 120 Vac 5.200 5.250 3.750 · 6.250 5.620 3.900 · · 10 A Switch/Breaker Ext. Terminal Strip · 10 A Switch/Breaker Ext. Terminal Strip Panel Mount 109 Enclosed 109 PSC100AB10 PSMN40A · 100 VA · 40 VA 120 Vac 120 Vac 6.250 5.620 3.900 · 3.250 2.750 2.000 · 10 A Switch/Breaker Ext. Terminal Strip Terminal Strip Enclosed 109 MT212-4 included 110 PSMN40AS · 40 VA 120 Vac 3.250 2.750 2.000 Terminal Strip MT212-4 included 110 PSH40A · 40 VA 120 Vac 4.500 5.438 4.500 · Ext. Terminal Strip Enclosed 110 PSH40AW · 40 VA 120 Vac 4.500 5.438 4.500 · Internal Wires Enclosed 110 PSH40AB10 · 40 VA 120 Vac 4.500 5.438 4.500 · · 10 A Switch/Breaker Ext. Terminal Strip Enclosed 110 PSH40AB10-EXT2 · 40 VA 120 Vac 4.500 5.438 4.500 · · 10 A Switch/Breaker Ext. Terminal Strip · Enclosed 111 PSH40AWB10 PSH75A · 40 VA 120 Vac 4.500 5.438 4.500 · · 10 A Switch/Breaker Internal Wires · 75 VA 480/277/240/208/120 Vac 4.500 5.438 4.500 · Ext. Terminal Strip Enclosed 110 Enclosed 111 PSH75AW PSH75AB10 · 75 VA 480/277/240/208/120 Vac 4.500 5.438 4.500 · Internal Wires · 75 VA 480/277/240/208/120 Vac 4.500 5.438 4.500 · · 10 A Switch/Breaker Ext. Terminal Strip Enclosed 111 Enclosed 111 PSH75AWB10 PSH100A · 75 VA 480/277/240/208/120 Vac 4.500 5.438 4.500 · · 100 VA 120 Vac 4.500 5.438 4.500 · · 10 A Switch/Breaker Internal Wires Ext. Terminal Strip Enclosed 111 Enclosed 112 PSH100AW · 100 VA 120 Vac 4.500 5.438 4.500 · Internal Wires Enclosed 112 PSH100AB10 · 100 VA 120 Vac 4.500 5.438 4.500 · · 10 A Switch/Breaker Ext. Terminal Strip Enclosed 112 PSH100AB10-EXT2 · 100 VA 120 Vac 4.500 5.438 4.500 · · 10 A Switch/Breaker Ext. Terminal Strip · Enclosed 111 PSH100AWB10 PSH75A75A · 100 VA 120 Vac 4.500 5.438 4.500 · · 75 VA, 75 VA 480/277/240/208/120 Vac 4.500 8.625 4.500 · · 10 A Switch/Breaker Internal Wires Ext. Terminal Strip Enclosed 112 Enclosed 112 PSH75A75AW PSH75A75AB10 · 75 VA, 75 VA 480/277/240/208/120 Vac 4.500 8.625 4.500 · · 75 VA, 75 VA 480/277/240/208/120 Vac 4.500 8.625 4.500 · Internal Wires · 10 A Switch/Breaker Ext. Terminal Strip Enclosed 112 Enclosed 112 PSH75A75AWB10 · 75 VA, 75 VA 480/277/240/208/120 Vac 4.500 8.625 4.500 · PSH100A100A · 100 VA, 100 VA 120 Vac 4.500 8.625 4.500 · · 10 A Switch/Breaker Internal Wires Ext. Terminal Strip Enclosed 112 Enclosed 113 PSH100A100AW · 100 VA, 100 VA 120 Vac 4.500 8.625 4.500 · Internal Wires Enclosed 113 PSH100A100AB10 · 100 VA, 100 VA 120 Vac 4.500 8.625 4.500 · · 10 A Switch/Breaker Ext. Terminal Strip Enclosed 113 PSH100A100AWB10 · 100 VA, 100 VA 120 Vac 4.500 8.625 4.500 · · 10 A Switch/Breaker Internal Wires Enclosed 113 AC POWER SUPPLIES: 200-500 VA MODEL # PSH500A PSH300A PSH200A PSMN500A PSMN300A PSMN200A TRANSFORMER INPUT POWER 120 VAC BREAKER PER SECONDARY HOUSING STYLE / SPEC HEIGHT WIDTH DEPTH OUTLET# OUTPUT CONFIGURATION SUB-PANEL PAGE · 500 VA (five 100 VA Outputs) 480/277/240/120 Vac 12.125 12.125 6.000 5 x 4 Amp Terminals Enclosed 113 · 300 VA (three 100 VA Outputs) 480/277/240/120 Vac 12.125 12.125 6.000 3 x 4 Amp Terminals Enclosed 114 · 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac 12.125 12.125 6.000 5 x 2 Amp Terminals Enclosed 114 · 500 VA (five 100 VA Outputs) 480/277/240/120 Vac 11.330 11.400 5.000 5 x 4 Amp Terminals Sub-panel Mount 113 · 300 VA (three 100 VA Outputs) 480/277/240/120 Vac 11.330 11.400 5.000 3 x 4 Amp Terminals Sub-panel Mount 114 · 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac 11.330 11.400 5.000 5 x 2 Amp Terminals Sub-panel Mount 114 PSH500A-LVC · 500 VA (five 100 VA Outputs) 480/277/240/120 Vac 12.125 12.125 6.000 5 x 4 Amp Terminals Enclosed with Low Voltage Compartment 115 PSH300A-LVC · 300 VA (three 100 VA Outputs) 480/277/240/120 Vac 12.125 12.125 6.000 3 x 4 Amp Terminals Enclosed with Low Voltage Compartment 115 PSH200A-LVC · 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac 12.125 12.125 6.000 5 x 2 Amp Terminals Enclosed with Low Voltage Compartment 116 PSH500AB10-LVC · 500 VA (five 100 VA Outputs) 120 Vac 12.125 12.125 6.000 · 5 x 4 Amp Terminals Enclosed with Low Voltage Compartment 117 PSH300AB10-LVC · 300 VA (three 100 VA Outputs) 120 Vac 12.125 12.125 6.000 · 3 x 4 Amp Terminals Enclosed with Low Voltage Compartment 118 PSH200AB10-LVC · 200 VA (five 40 VA Outputs) 120 Vac 12.125 12.125 6.000 · 5 x 2 Amp Terminals Enclosed with Low Voltage Compartment 118 = Class 2 UL Listed - see data sheet for specific Listing * = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A # = Convenience outlet has 4 Amp Breaker (800) 888-5538 | www.functionaldevices.com 107 AC & DC POWER SUPPLIES POWER SUPPLIES AC POWER SUPPLY PREPACKAGED KITS MODEL # CTRL-PS AUX SUB-PANEL / TRANS- INPUT 120 VAC OUTPUT ON/OFF MAIN BREAKER ON SECONDARY METAL TRACK SPEC FORMER(S) POWER HEIGHT WIDTH DEPTH OUTLETS WIRE SWITCH INPUT POWER * CONFIGURATION HOUSING MOUNT PAGE 40 VA 120 Vac 14.500 7.700 3.900 · MH1000 MT212-4 included 120 MHP3903100AB10 100 VA 120 Vac 12.500 24.500 6.500 · · · 10 A Switch/Breaker Ext. Terminal Strip MH3900 SP3803S (Polymetal) 120 MHP3903100A100AB10 100 VA, 100 VA 120 Vac 12.500 24.500 6.500 · · · 10 A Switch/Breaker Ext. Terminal Strip MH3900 SP3803S (Polymetal) 121 MHP3904100AB10 100 VA 120 Vac 12.500 24.500 6.500 · · · 10 A Switch/Breaker Ext. Terminal Strip MH3900 SP3804S (Perforated) 120 MHP3904100A100AB10 100 VA, 100 VA 120 Vac 12.500 24.500 6.500 · · · 10 A Switch/Breaker Ext. Terminal Strip MH3900 SP3804S (Perforated) 121 MHP4604100AB10 100 VA 120 Vac 16.150 20.000 6.720 · · · 10 A Switch/Breaker Ext. Terminal Strip MH4600 SP4604 (Perforated) 121 MHP4604100A100AB10 100 VA, 100 VA 120 Vac 16.150 20.000 6.720 · · · 10 A Switch/Breaker Ext. Terminal Strip MH4600 SP4604 (Perforated) 122 DC POWER SUPPLIES MODEL # VOLTAGE INPUT VOLTAGE OUTPUT OUTPUT ON/OFF HOUSING STYLE / SPEC CURRENT SWITCH HEIGHT WIDTH DEPTH TRACK MOUNT PAGE PSP24DA · 24 Vac Adjustable 1.5-28 Vdc ; Non-Isolated 300 mA 2.390 3.310 1.810 Enclosed 122 PSH24DWB10 120 Vac Fixed 24 Vdc ; Isolated 2.5 Amp · 4.500 5.438 4.500 Enclosed 123 PSH100A24DWB10 120 Vac Fixed 24 Vdc ; Isolated 100 VA, 24 Vac 2.5 Amp · 4.500 8.625 4.500 Enclosed 123 PSMN24DA · 24 Vac Adjustable 1.5-28 Vdc ; Non-Isolated 300 mA 1.750 2.750 1.750 MT212-2 included 124 PSMN24DAS · 24 Vac Adjustable 1.5-28 Vdc ; Non-Isolated 300 mA · 1.750 2.750 1.750 MT212-2 included 124 PSM20A12DAS · 24 Vac Adjustable 1.5-14 Vdc ; Isolated 300 mA · 2.750 4.000 2.250 MT212-4 included 124 PSM24A24DAS · 24 Vac Adjustable 1.5-28 Vdc ; Isolated 300 mA · 2.750 4.000 2.250 MT212-4 included 125 PSM19A24DAS · 120 Vac Adjustable 1.5-28 Vdc ; Isolated 300 mA · 2.750 4.000 2.250 MT212-4 included 125 PSMN40A24DS · 120 Vac Fixed 24 Vdc ; Isolated 1 Amp · 5.000 2.750 2.500 MT212-6 included 125 PSH100AB10-DC · 120 Vac Fixed 24 Vdc ; Isolated 2.5 Amp · 4.500 5.438 4.500 Enclosed 126 PSH100A100AB10-DC · 120 Vac Fixed 24 Vdc ; Isolated ; 100 VA, 24 Vac 2.5 Amp · 4.500 8.625 4.500 Enclosed 126 DIN MOUNT DC POWER SUPPLIES MODEL # PULS-ML15-241 PULS-PIC120-241D PULS-PIC240-241D PULS-PIM36-241 PULS-PIM60-241 PULS-PIM60-245 PULS-PIM90-241 PULS-PIM90-245 PULS-PIM90-245-L1 VOLTAGE INPUT · 100-240 Vac · 100-120Vac; 200-240Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac · 100-240 Vac VOLTAGE OUTPUT Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated OUTPUT CURRENT 600 mA 5 Amp 10 Amp 1.5 Amp 2.5 Amp 2.5 Amp 3.8 Amp 3.8 Amp 3.8 Amp ON/OFF SWITCH HEIGHT 2.950 4.880 4.880 3.540" 3.540" 3.540" 3.540" 3.540" 3.540" WIDTH 0.890 1.540 1.930" 0.860" 1.420" 1.420" 1.420" 1.420" 1.420" DEPTH 3.580 4.880 4.880 3.580" 3.580" 3.580" 3.580" 3.580" 3.580" HOUSING STYLE / TRACK MOUNT DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount For full product information on "PULS-" models, see our website for data sheets pages. = Class 2 UL Listed - see data sheet for specific Listing * = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A 108 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER SUPPLIES AC POWER SUPPLYIE: S1:21020VAVCACTOTO2424VAVCAC PSB40AB10 Single 40 VA Power Supply, 120 Vac to 24 Vac, 10 Amp Main Breaker, Open Bracket Panel Mount PSB100AB10 Single 100 VA Power Supply, 120 Vac to 24 Vac, 10 Amp Main Breaker, Open Bracket Panel Mount 120 Vac Convenience Outlet * Neutral 120 Vac Ground 120 Vac Aux. Output 2.250" 2.250" 3.750" ON RESET OFF OFF LED Indicator Com 24 Vac 10 Amp Main Breaker/Switch 24 Vac Breaker 24 Vac On/O Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 4.610" ON RESET OFF OFF 5.250" 5.200" SPECIFICATIONS Transformer: One 40 VA Split-Bobbin (PSB40AB10) One 100 VA Split-Bobbin (PSB100AB10) Primary: 120 Vac Secondary: 24 Vac, w/ LED Indicator Frequency: 50/60 Hz Over Current Protection: Inherently Limited + Circuit Breaker (PSB40AB10) Circuit Breaker (PSB100AB10) 24 Vac ON/OFF: On / Off Switch Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Class 2 REMOVABLE TERMINAL COVER PROVIDED Mounting: Panel mount Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508, C-UL, CE, RoHS Dimensions: 5.200 H x 5.250 W x 3.750 D Origin: Made of US and non-US parts AC POWER SUPPLYIE: S1:21020VAVCACTOTO2424VAVCAC PSC40AB10 Single 40 VA Power Supply, 120 Vac to 24 Vac, 10 Amp Main Breaker, Metal Enclosure PSC100AB10 Single 100 VA Power Supply, 120 Vac to 24 Vac, 10 Amp Main Breaker, Metal Enclosure 120 Vac Convenience Outlet * Neutral 120 Vac Ground 120 Vac Aux. Output 5.620" 2.245" 3.900" ON RESET OFF OFF LED Indicator Com 24 Vac 10 Amp Main Breaker/Switch 24 Vac Breaker 24 Vac On/O Switch Removable Access Plate * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 5.620" 6.250" 4.500" Shown Without Cover Class 2 Shown With Cover SPECIFICATIONS Transformer: One 40 VA Split-Bobbin, Inherently Limited (PSC100AB10) One 100 VA Split-Bobbin, Circuit Breaker (PSC100AB10) Primary: 120 Vac Secondary: 24 Vac, w/ LED Indicator Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Mounting: Mounting plate included (as shown) Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 6.250 H x 5.620 W x 3.900 D Origin: Made of US and non-US parts Notes: · To order without enclosure, see PSB40AB10 · To order without enclosure, see PSB100AB10. (800) 888-5538 | www.functionaldevices.com 109 AC POWER SUPPLIES: 120 VAC TO 24 VAC PSMN40A 40 VA Power Supply, 120 Vac to 24 Vac, 2.75" Track Mount PSMN40AS 40 VA Power Supply, 120 Vac to 24 Vac, Switch, 2.75" Track Mount LOAD 24 Vac LOAD 24 Vac POWER SUPPLIES Switch: On / O LINE 120 Vac LINE 120 Vac SPECIFICATIONS Transformers: One 40 VA Primary: 120 Vac Secondary: 24 Vac, isolated Frequency: 50/60 Hz Overload Protection: Inherently limited Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Secondary Voltage Present Dimensions: 3.25" H x 2.75"W x 2.00" D1/2.50" D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: MT212-4 Mounting Track Supplied ON/OFF Switch: 2 Position (PSMN40AS) Max. Ambient Temperature: 40° C Approvals: UL916, UL508, C-UL, CE, RoHS Origin: Made of US and non-US parts Class 2 AC POWER SUPPLIES PSH40A Series Single 40 VA Power Supply, 120 Vac to 24 Vac, UL Class 2, Metal Enclosure 120 Vac Convenience Outlet * 24 Vac Breaker 24 Vac ON OFF On/O Switch RESET LED Indicator OFF 5.438" 5.150" ON 4.500" RESET OFF 4.250" OFF 4.500" Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS 5.150" PSH40A SERIES SELECTION GUIDE Model # PSH40A PSH40AW PSH40AB10* PSH40AWB10* 120 Vac Outlets · · · · Aux Output Wire · · Main Breaker on Input Power 10 Amp Switch / Breaker 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires Class 2 Transformer: One 40 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508, C-UL, CE, RoHS, ^ Special Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac All Other Models Primary Wires BLK: 120 Vac WHT: Common "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/ uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling 110 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER SUPPLIES AC POWER SUPPLIES PSH40AB10-EXT2 Single 40 VA Power Supply, 120 Vac to 24 Vac, UL Class 2, 10 Amp Main Breaker with Extension Cord, Metal Enclosure Extension Cord 120 Vac Convenience Outlet * PSH100AB10-EXT2 Single 100 VA, 120 Vac to 24 Vac, UL Class 2, 10 Amp main breaker with input extension cord, Metal Enclosure 24 Vac Breaker 24 Vac ON OFF On/O Switch RESET LED Indicator OFF 36.000" Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 5.438" 5.150" ON 4.500" RESET OFF 4.250" OFF 5.150" 4.500" SPECIFICATIONS Class 2 PLUGS DIRECTLY INTO WIRED OUTLET BOX FOR USE ABOVE FALSE CEILINGS OR IN CONTROL PANELS Transformer: One 40 VA (PSH40A10-EXT2) One 100 VA (PSH100A10-EXT2) Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500H x 5.438 W x 4.500 D Origin: Made of US and non-US parts Input Wires: Powercord BLK: 120 Vac WHT: Neutral GRN: Ground Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. Output Wire: Auxiliary Load Output BLU: 120 Vac 9 Amp, max. AC POWER SUPPLIES PSH75A Series Single 75 VA Power Supply Multi- tap 480/277/240/208/120 to 24 Vac, UL Class 2, Metal Enclosure 120 Vac Convenience Outlet * 5.438" 5.150" 4.500" 24 Vac Breaker 24 Vac ON OFF On/O Switch RESET RESET LED Indicator OFF OFF ON 4.500" OFF 4.250" Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch 5.150" * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS Transformer: One 75 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts PSH75A SERIES SELECTION GUIDE Model # 120 Vac Aux Output Outlets Wire Main Breaker on Input Power PSH75A · PSH75AW · PSH75AB10* · · 10 Amp Switch / Breaker PSH75AWB10* · · 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires Class 2 Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac All Other Models Primary Wires** GRY: 480 Vac BRN: 277 Vac ORG: 240 Vac RED: 208 Vac WHT: 120 Vac BLK: Common "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/ uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling (800) 888-5538 | www.functionaldevices.com 111 AC POWER SUPPLIES PSH100A Series Single 100 VA, 120 Vac to 24 Vac, UL Class 2, Metal Enclosure POWER SUPPLIES 120 Vac Convenience Outlet * 24 Vac Breaker 24 Vac ON OFF On/O Switch RESET LED Indicator OFF 5.438" 5.150" ON 4.500" RESET OFF 4.250" OFF 4.500" Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 5.150" SPECIFICATIONS Transformer: One 100 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts PSH100A SERIES SELECTION GUIDE Model # PSH100A PSH100AW PSH100AB10* PSH100AWB10* 120 Vac Outlets · · · · Aux Output Wire · · Main Breaker on Input Power 10 Amp Switch / Breaker 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires Class 2 Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac All Other Models Primary Wires BLK: 120 Vac WHT: Common Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/ uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common AC POWER SUPPLIES PSH75A75A Series Dual 75 VA, Multi-tap 480/277/240/208/120 to 24 Vac, UL Class 2, Metal Enclosure 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 8.625" 8.250" 24 Vac Breaker ON OFF 24 Vac ON OFF On/O Switch ON OFF RESET ON OFF RESET LED Indicator OFF OFF 4.500" 4.250" 4.500" Com 24 Vac Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 8.250" SPECIFICATIONS Transformer: Two 75 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 H x 8.625 W x 4.500 D Origin: Made of US and non-US parts PSH75A75A SERIES SELECTION GUIDE Model # 120 Vac Aux Output Outlets Wire Main Breaker on Input Power PSH75A75A · PSH75A75AW · PSH75A75AB10* · · 10 Amp Switch / Breaker PSH75A75AWB10* · · 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires Class 2 Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac All Other Models Primary Wires** GRY: 480 Vac BRN: 277 Vac ORG: 240 Vac RED: 208 Vac WHT: 120 Vac BLK: Common "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common Notes: · All dual models: Model number denotes location of transformer within enclosure. PSH75A75A Left side Right side · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling · All primary voltages other than 120 Vac will result in the disabling of convenience outlets.** 112 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER SUPPLIES AC POWER SUPPLYIES PSH100A100A Series Dual 100 VA, 120 Vac to 24 Vac, UL Class 2, Metal Enclosure 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 24 Vac Breaker 24 Vac ON OFF ON OFF On/O Switch RESET LED Indicator OFF Com 24 Vac Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS 8.625" 8.250" ON ON OFF OFF RESET OFF 8.250" 4.500" 4.250" 4.500" PSH100A100A SERIES SELECTION GUIDE Model # PSH100A100A PSH100A100AW PSH100A100AB10* PSH100A100AWB10* 120 Vac Outlets · · · · Aux Output Wire Main Breaker on Input Power · 10 Amp Switch / Breaker · 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires Class 2 Transformer: Two 100 VA Split-Bobbin Input Wires: "B10 Models Only Over Current Protection: Circuit Breaker Input Power Wires Frequency: 50/60 Hz BLK: 120 Vac 24 Vac ON/OFF: On / Off Switch & Breaker WHT: Neutral Main Breaker ON/OFF: Switch / Breaker (10 Amp) GRN: Ground (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508, Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground C-UL, CE, RoHS, Output Wires: "B10 Models Only Special ^ Seismic Certification of Equipment and Auxiliary Output Components: OSP-0201-10 BLU: 120 Vac Dimensions: 4.500 H x 8.625 W x 4.500 D Origin: Made of US and non-US parts All Other Models Primary Wires BLK: 120 Vac WHT: Common "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/ uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling AC POWER SUPPLYIES PSH500A 500 VA Power Supply, Five 100 VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac, Metal Enclosure PSMN500A 500 VA Power Supply, Five 100 VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac, Polymetal Sub- panel Pre-Mounted 480 277 240 120 COMM ON 1 OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 24V COM 24V COM 24V COM 24V COM 24V COM User Connections PSMN500A SPECIFICATIONS Switch Indicator Breaker Transformer: One (1) 500 VA Over Current Protection: Circuit Breaker Primary: 480/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 H x 12.125 W x 6.000 D (PSH500A) 11.330 H x 11.400 W x 5.000 D (PSMN500A) Origin: Made of US and non-US parts Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Housing: NEMA1 Metal Enclosure (PSH500A) Notes: Sub-Panel: Plenum Rated Polymetal (PSMN500A) · To order UL508, add "-IC" to end of model number. · Primary voltage terminal cover available. · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling 5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously) · With 240 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature PSH500A Shown WithCover Class 2 PSH500A Shown Without Cover Standby Wattage: 48.515 W @ 120 Vac 48.699 W @ 240 Vac 49.564 W @ 277 Vac 48.255 W @ 480 Vac Full Load Primary Current: 4.66 A @ 120 Vac 2.41 A @ 240 Vac 2.06 A @ 277 Vac 1.17 A @ 480 Vac Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp (800) 888-5538 | www.functionaldevices.com 113 AC POWER SUPPLYIES PSH300A 300 VA Power Supply, Three 100 VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac, Metal Enclosure 480 277 240 120 COMM ON 1 OFF ON OFF 2 ON OFF 3 24V COM 24V COM 24V COM PSMN300A 300 VA Power Supply, Three 100 VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac, Polymetal Subpanel Pre-Mounted PSH300A Shown Without Cover POWER SUPPLIES User Connections PSMN300A SPECIFICATIONS Switch Indicator Breaker Transformer: One (1) 300 VA Over Current Protection: Circuit Breaker Primary: 480/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 H x 12.125 W x 6.000 D (PSH300A) 11.330 H x 11.400 W x 5.000 D (PSMN300A) Origin: Made of US and non-US parts Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Housing: NEMA1 Metal Enclosure (PSH300A) Notes: Sub-Panel: Plenum Rated Polymetal (PSMN300A) · To order UL508, add "-IC" to end of model number. · Primary voltage terminal cover available. · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling 3 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 3 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 3 Outputs Operated Simultaneously) · With 120 Vac primary input voltage · When all 3 outputs operated simultaneously, at room temperature AC POWER SUPPLYIES PSH200A 200 VA Power Supply, Five 40 VA Class 2 Outputs, 480/347/277/240/120 Vac to 24 Vac, Metal Enclosure 347 480 277 240 120 COMM ON 1 OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 24V COM 24V COM 24V COM 24V COM 24V COM SPECIFICATIONS Switch Indicator Breaker User Connections PSMN200A 200 VA Power Supply, Five 40 VA Class 2 Outputs, 480/347/277/240/120 Vac to 24 Vac, Polymetal Subpanel Pre-Mounted PSMN300A 347 VAC INPUT VOLTAGE PROVIDES DIRECT CONVERSION FROM MANY CANADIAN SYSTEMS TO CLASS 2 OUTPUTS PERFECT FOR ISOLATING UP TO FIVE ZONE CONTROLLERS Transformer: One (1) 200 VA Over Current Protection: Circuit Breaker Primary: 480/347/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 H x 12.125 W x 6.000 D (PSH200A) 11.330 H x 11.400 W x 5.000 D (PSMN200A) Origin: Made of US and non-US parts Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Housing: NEMA1 Metal Enclosure (PSH200A) Sub-Panel: Plenum Rated Polymetal (PSMN200A) Notes: · Primary voltage terminal cover available. 5 Secondaries: 24 Vac, with LED Indicators 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/347/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 40 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 1.6A up to 40° C ; 1.2A up to 60° C (When All 5 Outputs Operated Simultaneously) · With 120 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature PSH300A Shown Without Cover Class 2 Standby Wattage: 16.61 W @ 120 Vac 17.70 W @ 240 Vac 16.26 W @ 277 Vac 19.20 W @ 480 Vac Full Load Primary Current: 2.66 A @ 120 Vac 1.36 A @ 240 Vac 1.18 A @ 277 Vac 0.68 A @ 480 Vac Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp PSH200A Shown Without Cover Class 2 PSH200A Shown Without Cover Standby Wattage: 18.93 W @ 120 Vac 22.08 W @ 240 Vac 22.33 W @ 277 Vac 23.11 W @ 347 Vac 25.24 W @ 480 Vac Full Load Primary Current: 2.57 A @ 120 Vac 1.44 A @ 240 Vac 1.17 A @ 277 Vac 0.95 A @ 347 Vac 0.73 A @ 480 Vac Secondary Output Voltage vs. Load: 24.9 V @ 0.5 Amp 24.0 V @ 1.0 Amp 23.9 V @ 1.4 Amp 23.7 V @ 1.6 Amp 114 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER SUPPLIES AC POWER SUPPLY PSH500A-LVC 500 VA Power Supply, Five 100 VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac, Hi/Lo Voltage Separate Wiring Compartments, Metal Enclosure SPECIFICATIONS 480 277 240 120 COMM ON 1 OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 24V COM 24V COM 24V COM 24V COM 24V COM Switch Indicator Breaker User Connections PSH500A-LVC Shown With Full Cover & Access Plate PSH500A-LVC Shown Without High Voltage Cover & Low Voltage Access Plate PSH500A-LVC Shown Without Low Voltage Access Plate Class 2 Transformer: One (1) 500 VA Over Current Protection: Circuit Breaker Primary: 480/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 H x 12.125 W x 6.000 D Origin: Made of US and non-US parts Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS ^ Seismic Certification of Equipment and Components: OSP-0201-10 Housing: NEMA1 Metal Enclosure with Notes: high/low separation · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling 5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously) · With 240 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature Standby Wattage: 48.515 W @ 120 Vac 48.699 W @ 240 Vac 49.564 W @ 277 Vac 48.255 W @ 480 Vac Full Load Primary Current: 4.66 A @ 120 Vac 2.41 A @ 240 Vac 2.06 A @ 277 Vac 1.17 A @ 480 Vac Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp AC POWER SUPPLY PSH300A-LVC 300 VA Power Supply, Three 100 VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac, Hi/Lo Voltage Separate Wiring Compartments, Metal Enclosure 480 277 240 120 COMM ON 1 OFF ON OFF 2 ON OFF 3 24V COM 24V COM 24V COM Switch Indicator Breaker User Connections PSH300A-LVC Shown With Full Cover & Access Plate PSH300A-LVC Shown Without High Voltage Cover & Low Voltage Access Plate PSH300A-LVC Shown Without Low Voltage Access Plate SPECIFICATIONS Transformer: One (1) 300 VA Over Current Protection: Circuit Breaker Primary: 480/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 H x 12.125 W x 6.000 D Origin Made of US and non-US parts Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS ^ Seismic Certification of Equipment and Components: OSP-0201-10 Housing: NEMA1 Metal Enclosure Notes: · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling 3 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 3 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 3 Outputs Operated Simultaneously) Standby Wattage: 16.61 W @ 120 Vac 17.70 W @ 240 Vac 16.26 W @ 277 Vac 19.20 W @ 480 Vac Full Load Primary Current: 2.66 A @ 120 Vac 1.36 A @ 240 Vac 1.18 A @ 277 Vac 0.68 A @ 480 Vac Class 2 Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp · With 120 Vac primary input voltage · When all 3 outputs operated simultaneously, at room temperature (800) 888-5538 | www.functionaldevices.com 115 POWER SUPPLIES User Connections AC POWER SUPPLY PSH200A-LVC 200 VA Power Supply, Five 40 VA Class 2 Outputs, 480/347/277/240/120 Vac to 24 Vac, Hi/Lo Voltage Separate Wiring Compartments, Metal Enclosure 347 480 277 240 120 COMM ON 1 OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 24V COM 24V COM 24V COM 24V COM 24V COM PSH200A-LVC Shown With Full Cover & Access Plate PSH200A-LVC Shown Without High Voltage Cover & Low Voltage Access Plate PSH200A-LVC Shown Without Low Voltage Access Plate SPECIFICATIONS Switch Indicator Breaker Transformer: One (1) 200 VA Over Current Protection: Circuit Breaker Primary: 480/347/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 H x 12.125 W x 6.000 D Origin: Made of US and non-US parts Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Housing: NEMA1 Metal Enclosure 5 Secondaries: 24 Vac, with LED Indicators 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/347/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 40 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 1.6A up to 40° C ; 1.2A up to 60° C (When All 5 Outputs Operated Simultaneously) Standby Wattage: 18.93 W @ 120 Vac 22.08 W @ 240 Vac 22.33 W @ 277 Vac 23.11 W @ 347 Vac 25.24 W @ 480 Vac Full Load Primary Current: 2.57 A @ 120 Vac 1.44 A @ 240 Vac 1.17 A @ 277 Vac 0.95 A @ 347 Vac 0.73 A @ 480 Vac Class 2 Secondary Output Voltage vs. Load: 24.9 V @ 0.5 Amp 24.0 V @ 1.0 Amp 23.9 V @ 1.4 Amp 23.7 V @ 1.6 Amp · With 120 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature 116 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER SUPPLIES AC POWER SUPPLY PSH500AB10-LVC 500 VA Power Supply, Five 100 VA Class 2 Outputs, 120 Vac to 24 Vac, Hi/Lo Voltage Separate Wiring Compartments, Exterior 120 Vac Receptacle and Circuit Breakers Switches, Metal Enclosure Hot Neut GND 10 Amp Breaker/Switch 4 Amp Breaker 120 Vac Receptacle Chassis Ground Switch 4 Amp Breaker LED Indicator Switch 4 Amp Breaker LED Indicator 120 Vac Neutral Switch 4 Amp Breaker LED Indicator Switch 4 Amp Breaker LED Indicator Switch 4 Amp Breaker PSH500AB10-LVC Shown With High Voltage Cover & Low Voltage Access Plate SPECIFICATIONS LED Indicator Transformer: One (1) 500 VA Over Current Protection: Circuit Breaker Primary: 120 Vac Frequency: 50/60 Hz Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: 1 Outlet & Transformer) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 12.125 H x 12.125 W x 6.000 D Origin: Made of US and non-US parts Housing: NEMA1 Metal Enclosure with high/low separation 5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously) Notes: · 4A (Breaker protected) Convenience Receptacle Provided · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling Standby Wattage: 48.515 W @ 120 Vac Full Load Primary Current: 4.66 A @ 120 Vac Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp · When all 5 outputs operated simultaneously, at room temperature Class 2 (800) 888-5538 | www.functionaldevices.com 117 POWER SUPPLIES AC POWER SUPPLY PSH300AB10-LVC 300 VA Power Supply, Three 100 VA Class 2 Outputs, 120 Vac to 24 Vac, Hi/Lo Voltage Separate Wiring Compartments, Exterior 120 Vac Receptacle and Circuit Breakers Switches, Metal Enclosure Hot Neut GND 10 Amp Breaker/Switch 4 Amp Breaker 120 Vac Neutral 120 Vac Receptacle Chassis Ground Switch 4 Amp Breaker Switch 4 Amp Breaker Switch 4 Amp Breaker LED Indicator LED Indicator LED Indicator PSH300AB10-LVC Shown With High Voltage Cover & Low Voltage Access Plate Class 2 SPECIFICATIONS Transformer: One (1) 300 VA Over Current Protection: Circuit Breaker Primary: 120 Vac Frequency: 50/60 Hz Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: 1 Outlet & Transformer) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 12.125 H x 12.125 W x 6.000 D Origin: Made of US and non-US parts Housing: NEMA1 Metal Enclosure with high/low separation Notes: 3 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 120 Vac Finger-Safe Terminals, 8-18 AWG Output: 3 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously) · 4A (Breaker protected) Convenience Receptacle Provided · Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling Standby Wattage: 16.61 W @ 120 Vac Full Load Primary Current: 2.66 A @ 120 Vac Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp · When all 5 outputs operated simultaneously, at room temperature 118 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER SUPPLIES AC POWER SUPPLY PSH200AB10-LVC 200 VA Power Supply, Five 40 VA Class 2 Outputs, 120 Vac to 24 Vac, Hi/Lo Voltage Separate Wiring Compartments, Exterior 120 Vac Receptacle and Circuit Breakers Switches, Metal Enclosure Hot Neut GND 10 Amp Breaker/Switch 4 Amp Breaker 120 Vac Neutral 120 Vac Receptacle Chassis Ground Switch 2 Amp Breaker Switch 2 Amp Breaker Switch 2 Amp Breaker Switch 2 Amp Breaker Switch 2 Amp Breaker LED Indicator LED Indicator LED Indicator LED Indicator LED Indicator PSH200AB10-LVC Shown With High Voltage Cover & Low Voltage Access Plate Class 2 SPECIFICATIONS Transformer: One (1) 200 VA Over Current Protection: Circuit Breaker Primary: 120 Vac Frequency: 50/60 Hz Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: 1 Outlet & Transformer) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 12.125 H x 12.125 W x 6.000 D Origin: Made of US and non-US parts Housing: NEMA1 Metal Enclosure with Notes: high/low separation · 4A (Breaker protected) Convenience Receptacle Provided 5 Secondaries: 24 Vac, with LED Indicators 2 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 40 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire. Ambient Temperature Derating: 1.6A up to 40° C ; 1.2A up to 60° C (When All 5 Outputs Operated Simultaneously) Standby Wattage: 18.93 W @ 120 Vac Full Load Primary Current: 2.57 A @ 120 Vac Secondary Output Voltage vs. Load: 24.9 V @ 0.5 Amp 24.0 V @ 1.0 Amp 23.9 V @ 1.4 Amp 23.7 V @ 1.6 Amp · When all 5 outputs operated simultaneously, at room temperature (800) 888-5538 | www.functionaldevices.com 119 AC POWER SUPPLY CTRL-PS 40 VA Power Supply, 120 to 24 Vac, DIN rail and 14.5"x 7.7"x 3.9" Enclosure 120 Vac Line Input 7.70" 5.70" POWER SUPPLIES 14.50" 11.50" 14.50" ON OFF SPECIFICATIONS 24 Vac Device Output Transformer: One 40 VA Primary: 120 Vac Secondary: 24 Vac, isolated Frequency: 50/60 Hz Overload Protection: Inherently Limited Status: LED On = Activated ON/OFF Switch: 2 Position Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS (PSMN40AS) UL916, C-UL, CE, RoHS (MH1000 Series) Dimensions: 14.50 D x 7.70 W x 3.90 D Origin: Made of US and non-US parts Housing: NEMA 1 Metal Enclosure with screw cover 3.90" 7.70" Shown With Cover Notes: · Track mounted power supply may be ordered separately as model PSMN40AS. · 40 VA power supply mounted in MT212-4 track, high/low voltage barrier and 8.75 of 35 mm top hat DIN rail for mounting of desired controller in one metal enclosure. · Controller must be 9.50 x 6.75 x 3.50 or smaller with DIN rail mounting capability, or 9.50 x 6.75 x 3.125 without DIN rail mounting capability. · Controller not included. GREAT FOR ZONE & NETWORK CONTROLLERS AC POWER SUPPLYIES MHP3903100AB10 Single 100 VA Power Supply, Polymetal Subpanel Mounted, 12.5" x 24.5" x 6.5" Metal Enclosure 10.60" 12.50" MHP3904100AB10 Single 100 VA Power Supply, Perforated Steel Subpanel Mounted, 12.5" x 24.5" x 6.5" Metal Enclosure 1111.7.75050" " 5.15" 5.438" 5.150" 4.50" 4.500" 4.50" 4.25" 99..000000"" 1100.7.57005" " .050.050"0" ON 4.500" RESET OFF 4.250" OFF 5.15" 5.150" 1 199..000000"" 22.00" 24.50" 9.90.0000"0" 88.5.05000" " 6.50" 12.50" POWER SUPPLY (PS100AB10) 0.5.50000" " 1.21.244"" 1.10.077"" SELECTION GUIDE Model # MHP3903100AB10 MHP3904100AB10 Sub-Panel Polymetal Perforated Steel Class 2 Transformer: One 100 VA Split-Bobbin Input Wires: Input Power Wires Over Current Protection: Circuit Breaker BLK: 120 Vac Frequency: 50/60 Hz WHT: Neutral 24 Vac ON/OFF: On / Off Switch & Breaker GRN: Ground Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer) Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 H x 8.625 W x 4.500 D Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: Auxiliary Output BLU: 120 Vac Origin: Made of US and non-US parts POLYMETAL SUB-PANEL (SP3803S) Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13 METAL HOUSING Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 12.50" (W) x 24.50" (H) x 6.50" (D) PERFORATED STEEL SUB-PANEL (SP3804S) Mounting Area: 220.60 square Approvals: Plenum Rated Dimensions: 19.00" x 11.75" Mounting Area: 220.60 square Approvals: Plenum Rated Dimensions: 19.00" x 11.75" 120 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER SUPPLIES AC POWER SUPPLYIES MHP3903100A100AB10 Dual 100 VA Power Supplies, Polymetal Subpanel Mounted, 12.5" x 24.5" x 6.5" Metal Enclosure 10.60" 12.50" MHP3904100A100AB10 Dual 100 VA Power Supplies, Perforated Steel Subpanel Mounted, 12.5" x 24.5" x 6.5" Metal Enclosure 1111.7.75050" " 8.625" 88..22505" " 44..55000" " 44..5050"0" 44..2520"5" 99..000000"" 1100.7.57005" " .050.050"0" ON ON OFF OFF RESET OFF 88.2.2550"" 1 199..000000"" 22.00" 24.50" 9.90.0000"0" 88.5.05000" " 6.50" 12.50" (PS100A100AB10) 0.5.50000" " 11.2.42" 4" 1.07" 1.07" SELECTION GUIDE Model # MHP3903100A100AB10 MHP3904100A100AB10 Sub-Panel Polymetal Perforated Steel Class 2 Transformer: Two 100 VA Split-Bobbin Input Wires: Input Power Wires Over Current Protection: Circuit Breaker BLK: 120 Vac Frequency: 50/60 Hz WHT: Neutral 24 Vac ON/OFF: On / Off Switch & Breaker GRN: Ground Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer) Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 H x 8.625 W x 4.500 D Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: Auxiliary Output BLU: 120 Vac Origin: Made of US and non-US parts POLYMETAL SUB-PANEL (SP3803S) Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13 METAL HOUSING Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 12.50" (W) x 24.50" (H) x 6.50" (D) PERFORATED STEEL SUB-PANEL (SP3804S) Mounting Area: 220.60 square Approvals: Plenum Rated Dimensions: 19.00" x 11.75" Mounting Area: 220.60 square Approvals: Plenum Rated Dimensions: 19.00" x 11.75" AC POWER SUPPLY MHP4604100AB10 Single 100 VA Power Supply, Perforated Steel Subpanel Mounted, 16.15" x 20.0" x 6.72" Metal Enclosure 14.25" 14.87" 13.00" .88" 5.15" 5.438" 5.150" 4.50" 4.500" ON 4.500" RESET OFF 4.250" OFF 5.15" 5.150" 17.50" 20.00" 14.62" 12.87" 4.50" 4.25" 16.15" 6.72" 12.00" 1.44" POWER SUPPLY (PS100AB10) Transformer: One 100 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer) Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 H x 5.150 W x 4.500 D Origin: Made of US and non-US parts 1.24" .89" Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: Auxiliary Output BLU: 120 Vac Class 2 Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13 METAL HOUSING (MH4600) Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 16.15" (W) x 20.00" (H) x 6.72" (D) PERFORATED STEEL SUB-PANEL (SP4604) Mounting Area: 214.85 square Approvals: Plenum Rated Dimensions: 14.62" x 14.87" (800) 888-5538 | www.functionaldevices.com 121 17.50" AC POWER SUPPLY MHP4604100A100AB10 Dual 100 VA Power Supplies, Perforated Steel Subpanel Mounted, 16.15" x 20.0" x 6.72" Metal Enclosure 14.87" 14.25" 13.00" .88" ON OFF 8.625" 88..22505" " ON OFF RESET OFF 88.2.2550"" 44..5050"0" 44..2520"5" 44..55000" " 20.00" 14.62" 12.87" POWER SUPPLIES 16.15" 6.72" 12.00" 1.44" POWER SUPPLY (PS100A100AB10) Transformer: Two 100 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer) Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 H x 8.625 W x 4.500 D Origin: Made of US and non-US parts 1.24" .89" Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: Auxiliary Output BLU: 120 Vac ADC POWER SUPPLY: 24 VAC TO 1.5 - 28 VDC PSP24DA DC Power Supply, Non-Isolated Linear, 24 Vac to 1.5-28 Vdc, Adjustable Output, NEMA 1 Housing VOLTAGE INPUT 24 Vac Class 2 Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13 METAL HOUSING (MH4600) Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 16.15" (W) x 20.00" (H) x 6.72" (D) PERFORATED STEEL SUB-PANEL (SP4604) Mounting Area: 214.85 square Approvals: Plenum Rated Dimensions: 14.62" x 14.87" Wht/Yel Wht/Yel VOLTAGE OUTPUT Factory Set to 24 Vdc Adjustable from 1.5-28 Vdc + Wht/Red Wht/Blu Class 2 SPECIFICATIONS Voltage Input: 24 Vac, full-wave rectified Voltage Output: 1.5 - 28 Vdc non-isolated Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated ON/OFF Switch: None Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Output Current Ratings: 116 mA @ 10 Vdc 125 mA @ 12 Vdc 300 mA @ 24 Vdc Input Current Rating: 550 mA Maximum Percent Ripple: Notes: 0.0016%, 24 Vdc @ 300 mA · Requires a separate ungrounded transformer when used in Regulation: Load: 0.04% No Load to Full Load Line: 0.0125 V/V conjunction with 1/2 wave rectified power supplies, grounded 24 Vac transformers, or when 24 Vac and 24 Vdc are connected in common. 122 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® ADC POWER SUPPLY: 120 VAC TO 24 VDC PSH24DWB10 DC Power Supply, Single Switching, 120-24 Vdc at 2.5 Amp, Metal Enclosure 4.500" 4.250" POWER SUPPLIES 120 Vac Convenience Outlet * 5.438" 5.150" 4.500" 4.500" RESET RESET 4.250" OFF OFF 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 5.150" SPECIFICATIONS Input Voltage: 120 Vac Frequency: 50/60 Hz DC Output: 24 Vdc @ 2.5 Amp Over Current Protection: Circuit Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit)* Total Combined Output 9A Operating Temperature: 32 to 122°F Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Notes: · This device is not certified for use as a Class 2 power source. ADC POWER SUPPLY: 120 VAC TO 24 VAC AND 24 VDC PSH100A24DWB10 DC Power Supply, 100 VA, 120 to 24 Vac and Switching 120 to 24 Vdc at 2.5 Amp, Metal Enclosure Output Wires: DC Supply Output WHT/RED: 24 Vdc WHT/BLU: 24 Vdc COM Auxiliary Output BLU: 120 Vac 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 8.625" 8.250" ON OFF RESET OFF ON OFF RESET OFF LED Indicator 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 8.250" SPECIFICATIONS Transformer: One 100 VA Split-Bobbin Voltage Input: 120 Vac Frequency: 50/60 Hz Over Current Protection: Circuit Breaker 24 Vac ON/OFF: Switch / Breaker (4 Amp) Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer, and 24 Vdc)* Total Combined Output 9A Dimensions: 4.500 H x 8.625 W x 4.500 D Origin: Made of US and non-US parts 4.500" Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Notes: · This device is not certified for use as a Class 2 power source. Output Wires: DC Supply Output WHT/RED: 24 Vdc WHT/BLU: 24 Vdc COM Auxiliary Output BLU: 120 Vac Transformer Output WHT/YEL: 24 Vac WHT/BLU: 24 Vac COM (800) 888-5538 | www.functionaldevices.com 123 POWER SUPPLIES ADC POWER SUPPLYIES: 24 VAC TO 1.5 - 28 VDC PSMN24DA DC Power Supply, Non-Isolated Linear, 24 Vac to 1.5-28 Vdc, 300mA Adjustable Output, 2.75" Track Mount PSMN24DAS DC Power Supply, Non-Isolated Linear, 24 Vac to 1.5-28 Vdc, 300mA Adjustable Output, Switch, 2.75" Track Mount Toggle Switch : On / O Voltage Input 24 Vac Voltage Output Adjustable 1.5-28Vdc + Voltage Input 24 Vac Voltage Output Adjustable 1.5-28Vdc + Class 2 SPECIFICATIONS Voltage Input: 24 Vac, full-wave rectified Output Current Ratings: Voltage Output: 1.5 - 28 Vdc non-isolated 116 mA @ 10 Vdc Frequency: 50/60 Hz 125 mA @ 12 Vdc Overload Protection: Electrical and Thermal, Auto-Reset 300 mA @ 24 Vdc Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Input Current Rating: Power Status: LED On = Activated 550 mA Maximum Dimensions: 1.75"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212-2 Mounting Track Supplied ON/OFF Switch: None (PSMN24DA) 2 Position Toggle (PSMN24DAS) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Percent Ripple: 0.0016%, 24 Vdc @ 300 mA Regulation: Load: 0.04% No Load to Full Load Line: 0.0125 V/V Notes: · Requires a separate ungrounded transformer when used in conjunction with 1/2 wave rectified power supplies, grounded 24 Vac transformers, or when 24 Vac and 24 Vdc are connected in common. ADC POWER SUPPLY: 24 VAC TO 1.5 - 14 VDC PSM20A12DAS DC Power Supply, Isolated Linear, 24 Vac to 1.5Vdc-14Vdc, 300mA Adjustable Output, Track Mount Voltage Output Adjustable From 1.5-14 Vdc + Voltage Input 24 Vac Switch: On / O SPECIFICATIONS Voltage Input: 24 Vac Voltage Output: 1.5 - 14 Vdc Isolated Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 2.75"H x 4.00"W x 1.75"D1/2.25"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 and 2.750 MT212-4 Mounting Track Supplied ON/OFF Switch: 2 Position Approvals: Class 2, UL916, C-UL, CE, RoHS, Output Current Ratings: 300 mA @ 12 Vdc Input Current Rating: 950 mA Maximum Class 2 Percent Ripple: 0.0016%, 12 Vdc @ 300 mA Regulation: Load: 0.04% No Load to Full Load Line: 0.0080 mV/V 124 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER SUPPLIES ADC POWER SUPPLYIES: 24 VAC TO 1.5 - 28 VDC PSM24A24DAS DC Power Supply, Isolated Linear, 24 Vac to 1.5-28 Vdc, 300mA Adjustable Output, Track Mount PSM19A24DAS DC Power Supply, Isolated Linear, 120 Vac to 1.5- 28 Vdc, 300mA Adjustable Output, Track Mount Voltage Output Adjustable From 1.5-28 Vdc + Voltage Input 24 Vac Switch: On / O Voltage Output Adjustable From 1.5-28 Vdc + Voltage Input 120 Vac Switch: On / O SPECIFICATIONS Voltage Input: 24 Vac (PSM24A24DAS) 120 Vac (PSM19A24DAS) Voltage Output: 1.5 - 28 Vdc Isolated Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 2.75"H x 4.00"W x 1.75"D1/2.25"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 and 2.750 MT212-4 Mounting Track Supplied ON/OFF Switch: 2 Position Max. Ambient Temperature: 40° C (PSM19A24DAS) Approvals: Class 2, UL916, C-UL, CE, RoHS, Output Current Ratings: 116 mA @ 10 Vdc 125 mA @ 12 Vdc 300 mA @ 24 Vdc Input Current Rating: 950 mA Maximum (PSM24A24DAS) 150 mA Maximum (PSM19A24DAS) ADC POWER SUPPLY: 120 VAC TO 24 VDC PSMN40A24DS DC Power Supply, Isolated Linear, 120 Vac to 24 Vdc, 1 Amp Output, 2.75" Track Mount + Voltage Output 24 Vdc Voltage Input 120 Vac Switch: On / O Class 2 Percent Ripple: 0.0016%, 24 Vdc @ 300 mA Regulation: Load: 0.04% No Load to Full Load Line: 0.0080 mV/V (PSM24A24DAS) Line: 0.6250 mV/V (PSM19A24DAS) SPECIFICATIONS Voltage Input: 120 Vac Voltage Output: 24 Vdc Isolated Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 5.00"H x 2.75"W x 2.00"D1/2.50"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212-6 Mounting Track Supplied ON/OFF Switch: 2 Position Max. Ambient Temperature: 40° C Approvals: Class 2, UL916, C-UL, CE, RoHS, Output Current Ratings: 1 A @ 24 Vdc Input Current Rating: 400 mA Maximum Percent Ripple: 0.0016%, 24 Vdc @ 1 A Regulation: Load: 0.50% No Load to Full Load Line: 25.0000 mV/V Class 2 (800) 888-5538 | www.functionaldevices.com 125 POWER SUPPLIES ADC POWER SUPPLY PSH100AB10-DC Enclosed Single Switching DC Power Supplies, 120 to 24 Vdc @ 2.5 Amp, Class 2 120 Vac Convenience Outlet * 24 Vdc Breaker 24 Vdc ON OFF On/O Switch RESET LED Indicator OFF 5.438" 5.150" 4.500" ON 4.500" RESET OFF 4.250" OFF Com 24 Vdc 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 5.150" SPECIFICATIONS Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vdc ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL508, C-UL, CE, RoHS, FCC Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: Auxiliary Output BLU: 120 Vac AC P&ODWCEPROSWUEPRPSLYUPPLY: 120 VAC TO 24 VAC & 24 VDC PSH100A100AB10-DC Enclosed Dual Power Supplies, 100 VA, 120 to 24 Vac and 120 to 24 Vdc @ 2.5 Amp, Class 2 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 8.625" 24 Vdc Breaker 8.250" 24 Vdc ON OFF ON OFF On/O Switch RESET LED Indicator ON ON OFF OFF OFF RESET Com 24 Vac Com 24 Vdc 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch OFF 8.250" * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker 24 Vdc ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, 24 Vac, & 24 Vdc)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL508, C-UL, CE, RoHS, FCC Dimensions: 4.500 H x 8.625 W x 4.500 D Origin: Made of US and non-US parts 4.500" 4.250" 4.500" Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: Auxiliary Output BLU: 120 Vac Class 2 Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. Class 2 Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. 126 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® TRANSFORMERS TRANSFORMERS TR40VA002US TR100VA009US TR50VA001US US MANUFACTURED TRANSFORMERS · 40 VA through 96 VA · Single and dual hub · Foot or hub mountable · Circuit breaker models · Class 2 UL Listed · 24 Vac secondary · Single and multi-tap primaries Transformers may be foot mount, hub mount, or both. Transformers with the hub mount option will have either a single threaded hub or dual threaded hubs. Several transformers are provided with a circuit breaker and many are Class 2. Pigtail wires are standard on most models and are typically 8.00 in length. 1 All transformers utilize split-bobbin construction, making them inherently isolated. Custom transformers are also available (contact factory). Frequency: 50/60 Hz Hub Style: .5 NPT Hub Wire Length: 8 Typical with .5 Strip 1 Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) MTBF: 100,000 Hours @ 77° F Construction: Split-Bobbin Approvals: CE approved, RoHS. See charts for UL approvals. 1 = TR40VA022 = 8 Primary, 30 Secondary, with .5 Strip TR50VA019 = 28 Typical with .5 Strip TR100VA001-28 = 28 Typical with .5 Strip TR100VA002-20 = 8 Primary, 20 Secondary, with .5 Strip TR150VA001-28 = 28 Typical with .5 Strip Instructions inside product box include wire colors/voltages. Additional information on voltage and wire colors is available on individual data sheets on website. US MANUFACTURED TRANSFORMERS: 40-96 VA MADE IN MODEL # USA TR40VA001US · · TR40VA002US · · TR50VA001US · · TR50VA005US · · TR50VA022US · · TR100VA001US · · TR100VA002US · · TR100VA009US · · VA RATING 40VA 40VA 50VA 50VA 50VA 96VA 96VA 96VA STYLE 1 4 1 2 5 2 5 5 OVER CURRENT CLASS PROTECTION 2 Inherent · Inherent · Fuse · Circuit Brkr. · Circuit Brkr. · Circuit Brkr. · Circuit Brkr. · Circuit Brkr. · PRIMARY VOLTAGE (VAC) 120 120 120 120 480/277/240/208/120 120 120 480/277/240/208/120 SEC. VOLTAGE FOOT (VAC) MOUNT 24 · 24 · 24 · 24 · 24 · 24 · 24 · 24 · HUBS 1 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 1 Threaded 2 Threaded 2 Threaded L W H A B C 2.380" 2.200" 2.930" 1.720" 1.750" .980" 2.380 2.200 2.920 1.720 1.750 .980" 2.750" 2.200" 2.910" 2.060" 1.750" 1.330" 3.270 2.525 3.250 2.210 2.000 1.130 3.260 2.525 3.290 2.190 2.000 1.120 3.780 2.500 3.290 2.740 2.000 1.630 3.750 2.500 3.290 2.690 2.000 1.600 3.780 2.500 3.270 2.720 2.000 1.630 = Class 2 UL Listed - see data sheet for specific Listing For full product information, see data sheets on website. (800) 888-5538 | www.functionaldevices.com 127 TRANSFORMERS STYLE 1 Single Hub & Foot Mount STYLE 2 Single Hub & Foot Mount with Circuit Breaker STYLE 3 Single Hub & Foot Mount with Circuit Breaker STYLE 4 Dual Hub & Foot Mount TRANSFORMERS STYLE 5 Dual Hub & Foot Mount with Circuit Breaker STYLE 6 Single Hub & Side Opening with Circuit Breaker STYLE 7 Two Bottom Openings & Foot Mount STYLE 8 Single Hub, Side Opening & Foot Mount STYLE 9 Single Hub & Dual Terminal Secondary STYLE 10 Two End-Bell Openings, & Foot Mount with Circuit Breaker STYLE 11 Two Side Openings & Foot Mount STYLE 12 Dual Hub & Foot Mount with Circuit Breaker Dimensions: See charts. C STYLE 13 90º Conduit Connector & Mounting Plate Opening A L 1 .50" 8.00" D B 1 8.00" .50" 128 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® W H TRANSFORMERS TRANSFORMERS TRANSFORMERS: 20-50 VA MODEL # VA RATING STYLE OVER CURRENT PROTECTION CLASS 2 TR20VA001 · 20VA 1 Inherent · PRIMARY VOLTAGE (VAC) 120 SEC. VOLTAGE (VAC) 24 FOOT MOUNT · HUBS 1 Threaded L W H A B C D 2.226" 1.877" 2.595" 1.625" 1.619" 1.013" 2.125" TR20VA002 · 20VA 4 Inherent · 208 24 · 2 Threaded 2.296" 1.902" 2.616" 1.604" 1.665" 1.020" 2.114" TR20VA003 · 20VA 1 Inherent 24 24 · 1 Threaded 2.272" 1.900" 2.628" 1.635" 1.686" 1.023" 2.153" TR20VA004 · 20VA 4 Inherent · 277/240/208/120 24 · 2 Threaded 2.310" 1.890" 2.625" 1.540" 1.625" 1.000" 2.100" TR20VA007 · 20VA 1 Inherent · 277 24 · 1 Threaded 2.302" 1.895" 2.607" 1.608" 1.685" 1.019" 2.107" TR40VA001 · 40VA 1 Inherent · 120 24 · 1 Threaded 2.607" 2.169" 2.906" 2.020" 1.786" 1.204" 2.545" TR40VA002 · 40VA 4 Inherent · 120 24 · 2 Threaded 2.634" 2.177" 2.886" 2.007" 1.775" 1.206" 2.564" TR40VA003 · 40VA 1 Inherent · 24 24 · 1 Threaded 2.653" 2.171" 2.882" 2.033" 1.779" 1.185" 2.580" TR40VA004 · 40VA 4 Inherent · 277/240/208/120 24 · 2 Threaded 2.631" 2.177" 2.882" 1.998" 1.774" 1.189" 2.553" TR40VA013 · 40VA 2 Circuit Brkr. 480/277/240/208 120 · 1 Threaded 3.267" 2.505" 3.000" 1.699" 1.986" 1.114" 3.325" TR40VA015 · 40VA 1 Internal Thermal · 240/208/120 24 · 1 Threaded 2.628" 2.175" 2.907" 2.040" 1.780" 1.188" 2.590" TR40VA022 # · 40VA 4 Inherent · 120 24 · 2 Threaded 2.660" 2.172" 2.891" 1.980" 1.786" 1.201" 2.526" TR40VA040 ^ · 40VA 9 Internal Thermal · 240/208/120 24 · 1 Threaded 2.728" 2.171" 2.890" 1.995" 1.792" 1.215" 2.550" TR50VA001 · 50VA 1 Fuse · 120 24 · 1 Threaded 2.677" 2.178" 2.879" 2.109" 1.793" 1.253" 2.664" TR50VA002 · 50VA 4 Fuse · 120 24 · 2 Threaded 2.696" 2.181" 2.908" 2.053" 1.788" 1.278" 2.614" TR50VA003 · 50VA 4 Fuse · 240/208 24 · 2 Threaded 2.695" 2.181" 2.899" 2.082" 1.778" 1.294" 2.646" TR50VA004 · 50VA 5 Circuit Brkr. · 480/277/240/120 24 · 2 Threaded 3.475" 2.513" 3.014" 1.858" 1.970" 1.291" 2.490" TR50VA005 · 50VA 2 Circuit Brkr. · 120 24 · 1 Threaded 3.489" 2.515" 3.008" 1.870" 1.971" 1.294" 2.463" TR50VA006 · 50VA 1 Fuse · 277 24 · 1 Threaded 2.763" 2.182" 2.898" 2.135" 1.790" 1.322" 2.698" TR50VA007 · 50VA 4 Fuse · 277 24 · 2 Threaded 2.715" 2.173" 2.886" 2.661" 1.784" 1.276" 2.790" TR50VA008 · 50VA 5 Circuit Brkr. 480/277/240/208 120 · 2 Threaded 3.440" 2.510" 3.012" 1.932" 1.945" 1.346" 2.523" TR50VA009 · 50VA 5 Circuit Brkr. · 240/208/120 24 · 2 Threaded 3.412" 2.504" 3.014" 1.864" 2.000" 1.313" 2.485" TR50VA014 · 50VA 2 Circuit Brkr. · 277 24 · 1 Threaded 3.479" 2.509" 3.009" 1.873" 1.965" 1.285" 2.480" TR50VA015 · 50VA 2 Circuit Brkr. · 480/277/240/208/120 24 · 1 Threaded 3.405" 2.517" 3.013" 1.875" 1.985" 1.316" 2.484" TR50VA016 · 50VA 2 Circuit Brkr. · 240/208/120 24 · 1 Threaded 3.345" 2.510" 3.028" 1.842" 1.978" 1.325" 2.454" TR50VA017 · 50VA 2 Circuit Brkr. · 480/277/208 24 · 1 Threaded 3.470" 2.520" 3.031" 1.880" 1.872" 1.292" 2.460" TR50VA018 · 50VA 13 480/277/240/208 120 1, 90° Conduit Connector, 1 Mounting Plate Opening Refer to data sheet on website. TR50VA019 # 50VA 11 Inherent · 277/120 24 · 2 Side Openings 2.470" 2.170" 2.896" 1.850" 1.740" 1.130" 2.512" TR50VA027 · 50VA 2 Circuit Brkr. · 240 24 · 1 Threaded 3.450" 2.500" 3.060" 2.030" 1.911" 1.260" 2.450" FOR 75 - 375 VA TRANSFORMERS, SEE NEXT PAGE. For full product information, see data sheets on website. = UL Listed - see data sheet for specific Listing = UL Component Recognized - see data sheet for specific Listing # = Refer to website for more wire length information ^ = Dual Terminal Secondary (800) 888-5538 | www.functionaldevices.com 129 TRANSFORMERS TRANSFORMERS TRANSFORMERS: 75-375 VA MODEL # OVER VA CURRENT CLASS RATING STYLE PROTECTION 2 TR75VA001 · 75VA 2 Circuit Brkr. · PRIMARY VOLTAGE (VAC) 120 SEC. VOLTAGE FOOT (VAC) MOUNT 24 · HUBS 1 Threaded LWH A B C D 3.743" 2.506" 3.016" 2.256" 1.974" 1.711" 2.873" TR75VA002 · 75VA 5 Circuit Brkr. · 120 24 · 2 Threaded 3.890" 2.508" 3.013" 2.290" 1.952" 1.701" 2.882" TR75VA003 · 75VA 2 Circuit Brkr. · 277 24 · 1 Threaded 3.875" 2.507" 3.037" 2.269" 1.978" 1.684" 2.860" TR75VA004 · 75VA 6 Circuit Brkr. · 480/240/208/120 24 · 1 Threaded 1 Side Opening 3.802" 2.515" 3.050" 2.244" 1.990" 1.665" 2.850" TR75VA005 · 75VA 2 Circuit Brkr. · 480/240/208/120 24 · 1 Threaded 3.880" 2.515" 3.030" 2.270" 1.975" 1.700" 2.854" TR75VA007 · 75VA 5 Circuit Brkr. · 480/240/208/120 24 · 2 Threaded 3.883" 2.504" 3.034" 2.287" 1.981" 1.708" 2.813" TR100VA001 · 96VA 2 Circuit Brkr. · 120 24 · 1 Threaded 4.085" 2.515" 3.030" 2.486" 1.975" 1.900" 3.082" TR100VA001-28 # · 96VA 2 Circuit Brkr. · 120 24 · 1 Threaded 4.085" 2.515" 3.030" 2.486" 1.975" 1.900" 3.082" TR100VA002 · 96VA 5 Circuit Brkr. · 120 24 · 2 Threaded 4.077" 2.504" 3.023" 2.470" 1.975" 1.888" 3.095" TR100VA002-20 # · 96VA 5 Circuit Brkr. · 120 24 · 2 Threaded 3.973" 2.518" 3.033" 2.486" 1.865" 1.924" 3.060" TR100VA004 · 96VA 5 Circuit Brkr. · 480/277/240/120 24 · 2 Threaded 4.173" 2.523" 3.041" 2.647" 1.976" 2.086" 3.268" TR100VA005 · 96VA 2 Circuit Brkr. · 480/277/240/120 24 · 1 Threaded 4.258" 2.510" 3.030" 2.670" 1.968" 2.065" 3.260" TR100VA008 · 96VA 5 Circuit Brkr. 480/277/240/208 120 · 2 Threaded 4.220" 2.525" 3.022" 2.690" 1.970" 2.082" 3.272" TR100VA009 · 96VA 5 Circuit Brkr. · 480/277/240/208/120 24 · 2 Threaded 4.270" 2.500" 3.060" 2.750" 1.975" 2.000" 2.252" TR100VA015 · 96VA 2 Circuit Brkr. · 480/277/240/208/120 24 · 1 Threaded 4.270" 2.500" 3.060" 2.699" 2.030" 2.065" 3.270" TR100VA026 · 96VA 5 Circuit Brkr. · 347/120 24 · 2 Threaded 4.040" 2.500" 3.050" 2.500" 2.030" 1.830" 3.070" TR100VA027 · 96VA 2 Circuit Brkr. · 240 24 · 1 Threaded 4.050" 2.500" 3.070" 2.510" 2.030" 1.880" 3.063" TR150VA001 · 150VA 3 Circuit Brkr. 120 24 · 1 Threaded 3.650" 3.800" 3.183" 2.560" 3.150" 1.438" 3.514" TR150VA001-28 # · 150VA 3 Circuit Brkr. 120 24 · 1 Threaded 3.650" 3.800" 3.183" 2.560" 3.150" 1.438" 3.514" TR150VA002 · 150VA 12 Circuit Brkr. 120 24 · 2 Threaded 3.620" 3.785" 3.160" 2.568" 3.147" 1.456" 3.511" TR150VA008 · 150VA 12 Circuit Brkr. 480/277/240/208 120 · 2 Threaded 4.283" 3.786" 3.161" 3.211" 3.148 " 2.116" 4.177" TR175VA001 · 175VA 7 240/208 24 · 2 Bottom Openings 3.801" 3.790" 3.163" 3.264" 3.141" 2.151" 4.197" TR175VA002 TR175VA003 TR240VA001 · 175VA 4 · 175VA 1 Thermal Fuse on Primary · 240VA 8 120 24 · 2 Threaded 3.800" 3.790" 3.189" 3.220" 3.150" 2.100" 4.180" 120 24 · 1 Threaded 4.030" 3.786" 3.161" 3.189" 3.155" 2.127" 4.153" 120 24 · 1 Threaded 1 Bottom Opening 3.957" 3.750" 4.530" 3.350" 3.180" 1.932" 4.025" TR300VA002 300VA 10 Circuit Brkr. 480/240/208/120 24 · 2 End-Bell Openings 5.499" 3.750" 4.500" 3.859" 3.187" 2.526" 4.526" TR375VA001 · 375VA 7 120 24 · 2 Bottom Openings 4.592" 3.747" 4.504" 3.933" 3.181" 2.516" 4.630" FOR 20 - 50 VA TRANSFORMERS, SEE PREVIOUS PAGE. For full product information, see data sheets on website. = UL Listed - see data sheet for specific Listing = UL Component Recognized - see data sheet for specific Listing # = Refer to website for more wire length information ^ = Dual Terminal Secondary 130 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® SPECIALTY PERIPHERAL CONTROLS RIBLB-6 RIBMNLB-2 SPECIALT Y PERIPHERAL CONTROLS RIBMN24Q4C-PX If we do not already build a device with specifications or packaging configurations you require, we will be happy to quote and design one for you. Functional Devices, Inc. is actively involved in the development, manufacturing, and production of special peripheral devices. They are either variations of existing Functional Devices products or entirely unique devices. We will help provide you with a product to RIBMNA1D0 fit your specific needs. Please contact us so we may review your project and special requirements. Air Handling Unit Fan Safety Shutdown VIEW VIDEO FAN SAFETY ALARM CIRCUITS / GENERAL PURPOSE LOGIC BOARDS MODEL # RIBMNLB · RIBLB · RIBMNWLB-7-BC · RIBMNLB-6 · RIBMNLB-4 · RIBMNLB-2 · RIBMNLB-1 · RIBLB-6 · RIBLB-4 · RIBLB-2 · RIBMNLB-6NO · RIBMNLB-4NO · RIBMNLB-2NO · POWER INPUT 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc ALARM CIRCUITS 4 4 7 6 4 2 1 6 4 2 6 4 2 COMPATIBLE · HOUSING STYLE * H D H H H H H D D D H H H TRACK MOUNT INCLUDED MT212-6 MT212-6 MT212-6 MT212-4 MT212-4 MT212-4 MT212-6 MT212-4 MT212-4 SPEC PAGE 132 133 134 135 135 135 136 137 137 137 138 138 138 I/O EXPANDERS MODEL # RIBMN24Q2C · RIBMN24Q3C · RIBMN24Q4C · RIBMN24Q4C-PX · POWER INPUT 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc RELAY CONTACTS 2 SPDT 3 SPDT 4 SPDT 4 SPDT TRACK MOUNT INCLUDED MT212-4 MT212-4 MT212-6 MT212-6 SPEC PAGE 139 139 140 140 MANUAL ANALOG OVERRIDE SWITCH MODEL # RIBMNA1D0 POWER INPUT 24 Vac/dc SWITCH Manual / Auto TRACK MOUNT ^ MT212 Series SPEC PAGE 141 = UL Listed - see data sheet for specific Listing * = See Housing Guide on page 201 ^ = Track mount sold separately (800) 888-5538 | www.functionaldevices.com 131 SPECIALT Y PERIPHERAL CONTROLS FAN SAFETY ALARM CIRCUIT RIBMNLB AHU Fan Safety Alarm Circuit, 24 Vac/dc Power Input, 2.75" Track Mount Power Input 4A Max. Dry Contact Inputs (From Field) Powered Contact Outputs 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 3A @ 24Vac /dc 750mA @ 24Vac/dc 1 2 24 Vac/dc Power On 3 4 Low Limit 1 5 Static Pressure Limit 1 6 Smoke Detector/FA Low Limit On Static Smoke Pressure Detector/FA On On Latched Input Selector DIP Switch Latch Reset Low Limit Relay Static Pressure Relay Low Limit Static Pressure Digital In Digital In 10 11 12 13 1 7 Fan Status Fan Status On 1 8 24V Comm Actuator Power 1 9 24V Comm Fan Safety Smoke Detector/ FA Relay Fan Status Relay Master Relay Master Relay On Smoke Detector/ Fan Status FA Digital In Digital In 14 15 16 17 For Indoor Use in Dry Locations 8A @ 24Vac/dc J1 Jumper 8A @ 24Vac/dc 8A @ 24Vac/dc 8A @ 24Vac/dc Dry Contact Outputs (To Controller) Dry Contact Output 10A @ 277 Vac 10A @ 30 Vdc 1/2 HP@120/240Vac B300 Pilot Duty CODE VER. 1.0 CAN BE USED TO ISOLATE FIELD DEVICES FROM EACH OTHER AND FROM CONTROLLER, NOT ONLY FAN CIRCUITS SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 250ms Power Input: 4 Amp Max @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.00"H x 2.75"W x 0.75"D1/1.25"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL864, C-UL, CE, RoHS, CSFM Gold Flash: No Override Switch: No Notes: · RIBMNLB has four Alarm Inputs and one Master Alarm. A master relay will open if any one of the normally-closed (N/C) inputs open. LED status of all outputs and the master relay is provided. The RIBMNLB is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB is enclosed in a NEMA 1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The master relay has two general-purpose outputs: one 24 V output terminal and one dry contact output rated up to 10 Amp @ 277 Vac. Fan status contact controls actuator power. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown. Model RIBMNLB combines all the relay logic to facilitate fan status, fan safety control, and damper actuator control. It is intended for use in a circuit that will control fan start/stop and fan safety shut-down circuit monitors three critical inputs: · Low-limit freeze protection (to stop fan and remove power from damper actuator) · Static pressure (to monitor for hi/low pressure condition) · Smoke detector / fire alarm Master relay opens to shut down AHU when any Normally Closed input opens. Integral DIP switch allows any input to be latched. Input can be reset with push button or by cycling unit power. Installing J1 jumper allows Fan Status input to control Master Relay, like the other 3 inputs. Panel Black Black RC-1 5Amp White White Green TX-1 1 x 1 24Vac 1 x 2 DC-1 Power 24Vac COM DC-1 DO-3 Digital inputs to controller 1 R4 FS-S 24Vac 16 Fan Status DI 17 R1 LL-A 10 Low Limit DI 11 R2 SP-A 12 Static Press Alarm DI 13 R3 Smoke/Fire Alarm 14 Smoke / Fire Alarm DI 15 DL-1 2 24Vac R1 LL-A R2 SP-A R3 SMK/FA 1 9 PB-1 R1 LL-A R1 LL-A 3 4 1 5 R2 SP-A 1 6 R3 SMK/FA 1 R4 FS-S 7 RIBMNLB (Track Mount) RIBLB (Enclosed) At power-up, delay 2 sec before DL-1 becomes activated R4 FS-S 1 8 DL-1 Field H 120Vac N Emergency Power G with ground X1 120Vac X2 Starter H O A Contactor Ols RIBTU2C Wht/Blu Blu Yel Wht/Yel Org Gry/Wht Gry Prp Wht/Prp Brn Fan Safety Relay Low Limit Static Pressure Smoke Detector / Fire Alarm Tn To Motor Status FS-S RIBX Series Fan Status Actuator Power This drawing represents: · Only Low Limit Latch Set · J1 Jumper Not Installed 132 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® SPECIALT Y PERIPHERAL CONTROLS FAN SAFETY ALARM CIRCUIT RIBLB AHU Fan Safety Alarm Circuit, 24 Vac/dc Power Input, NEMA 1 Housing Power Input Dry Contact Inputs (From Field) Powered Contact Outputs 4A Max. 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 3A @ 24Vac /dc 750mA @ 24Vac/dc 1 2 24 Vac/dc Power On 3 4 Low Limit 1 5 Static Pressure Limit 1 6 Smoke Detector/FA Low Limit On Static Smoke Pressure Detector/FA On On Latched Input Selector DIP Switch Latch Reset Low Limit Relay Static Pressure Relay Low Limit Static Pressure Digital In Digital In 10 11 12 13 1 7 Fan Status Fan Status On 1 8 24V Comm Actuator Power 1 9 24V Comm Fan Safety Smoke Detector/ FA Relay Fan Status Relay Master Relay Master Relay On Smoke Detector/ Fan Status FA Digital In Digital In 14 15 16 17 For Indoor Use in Dry Locations 8A @ 24Vac/dc J1 Jumper 8A @ 24Vac/dc 8A @ 24Vac/dc 8A @ 24Vac/dc Dry Contact Outputs (To Controller) SPECIFICATIONS Dry Contact Output 10A @ 277 Vac 10A @ 30 Vdc 1/2 HP@120/240Vac B300 Pilot Duty CODE VER. 1.0 CAN BE USED TO ISOLATE FIELD DEVICES FROM EACH OTHER AND FROM CONTROLLER, NOT ONLY FAN CIRCUITS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 250ms Power Input: 4 Amp Max @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL864, C-UL, CE, RoHS, CSFM Housing Rating: UL Listed, NEMA 1, C-UL, CE Gold Flash: No Override Switch: No Panel Black Black RC-1 5Amp White White Green TX-1 1 x 1 24Vac 1 x 2 DC-1 Power 24Vac COM DC-1 DO-3 Notes: · RIBMNLB and RIBLB have four Alarm Inputs and one Master Alarm. A master relay will open if any one of the normally-closed (N/C) inputs open. LED status of all outputs and the master relay is provided. The RIBMNLB is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB is enclosed in a NEMA 1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The master relay has two general-purpose outputs: one 24 V output terminal and one dry contact output rated up to 10 Amp @ 277 Vac. Fan status contact controls actuator power. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown. Model RIBMNLB combines all the relay logic to facilitate fan status, fan safety control, and damper actuator control. It is intended for use in a circuit that will control fan start/stop and fan safety shut-down circuit monitors three critical inputs: · Low-limit freeze protection (to stop fan and remove power from damper actuator) · Static pressure (to monitor for hi/low pressure condition) · Smoke detector / fire alarm Master relay opens to shut down AHU when any Normally Closed input opens. Integral DIP switch allows any input to be latched. Input can be reset with push button or by cycling unit power. Installing J1 jumper allows Fan Status input to control Master Relay, like the other 3 inputs. Digital inputs to controller 1 R4 FS-S 24Vac 16 Fan Status DI 17 R1 LL-A 10 Low Limit DI 11 R2 SP-A 12 Static Press Alarm DI 13 R3 Smoke/Fire Alarm 14 Smoke / Fire Alarm DI 15 DL-1 2 24Vac R1 LL-A R2 SP-A R3 SMK/FA 1 9 PB-1 R1 LL-A R1 LL-A 3 4 1 5 R2 SP-A 1 6 R3 SMK/FA 1 R4 FS-S 7 RIBMNLB (Track Mount) RIBLB (Enclosed) At power-up, delay 2 sec before DL-1 becomes activated R4 FS-S 1 8 DL-1 Field H 120Vac N Emergency Power G with ground X1 120Vac X2 Starter H O A Contactor Ols RIBTU2C Wht/Blu Blu Yel Wht/Yel Org Gry/Wht Gry Prp Wht/Prp Brn Fan Safety Relay Low Limit Static Pressure Smoke Detector / Fire Alarm Tn To Motor Status FS-S RIBX Series Fan Status Actuator Power This drawing represents: · Only Low Limit Latch Set · J1 Jumper Not Installed (800) 888-5538 | www.functionaldevices.com 133 SPECIALT Y PERIPHERAL CONTROLS FAN SAFETY ALARM CIRCUIT RIBMNWLB-7-BC AHU Fan Safety Alarm and General Purpose Logic Circuit, BACnet MS/TP Network, 24 Vac/dc Power Input, Two Binary Outputs + Override, Seven Binary Inputs, 2.75" Track Mount BI 5 - BI 7 Clear Latches Pushbutton BI Latched Indicator BI 7 BI 6 BI 5 Power/Stat CLOSED 123456 CLOSED 123456 OPEN CLOSE TO OVERRIDE BI 1-BI 6 OPEN CLOSE TO MAKE LATCHING INPUT BI 1-B1 6 MSB 1 2 3 4 5 6 LSB 7 8 9 10 BACnet MSTP 1 2 3 4 5 6 7 8 9 10 CLOSED CLOSED 12 12 OPEN OPEN ON ON OFF OFF AUTO AUTO BO 1-1 BO 1-2 Power Input BO 2 RIBMNWLB-7-BC BI 1 BI 2 BI 3 BI 4 B(+) A(-) REF 24V 24V 24V 24V COMM COMM N/C C N/O N/C N/O C BI 1 - BI 4 SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Power Input: 24 Vac/dc: 50-60 Hz Max current input determined by adding load current user applies to BO 1-1 (3A Max) plus 75 mA @ 24 Vac or 30 mA @ 24 Vdc depending on power source sup- plied by user to power RIB device, 24 Vac or 24 Vdc Dimensions: 6.62"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Approvals: UL864, UL916, C-UL, CE, RoHs, CSFM Relay Rating, BO 1-1: 3 Amp Max @ 24 Vac or 24 Vdc (depending on power source supplied by user to power RIB device) Relay Rating, BO 1-2: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac Relay Rating, BO 2: 20 Amp Resistive @ 277 Vac 5 Amp @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac 1 HP @ 120 Vac 2 HP @ 277 Vac Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Notes: Selectable) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. · Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Dry-Contact-Output Rated Up to 10A @ 277Vac 3A Max from 24V Input Supply BO 1-2 BO 1-1 BO 2 Dry-Contact Ouput Rated Up to 20A @ 277Vac, 5A @ 480Vac R1-1 R2-1 R3-1 R4-1 R5-1 R6-1 ON OFF AUTO BO 1 BO 1 Indicator 24 Vac/dc Supply Input BO 2 BI 7 Indicator ON OFF AUTO BO 2 BI 7 BO 2 Indicator Fan Current Stat BI Latch Select DIP Switches Indicators BI Override DIP Switches BI 1 Latch BI 1 Override R1 R1-2 BI 1 Indicator BI 2 Latch BI 2 Override R2 R2-2 BI 2 Indicator BI 3 Latch BI 3 Override R3 R3-2 BI 3 Indicator BI 4 Latch BI 4 Override R4 R4-2 BI 4 Indicator BI 1-BI 6 BI 1 Low Temp Alarm BI 2 High Temp Alarm BI 3 Low Pres Alarm BI 4 High Pres Alarm BI 5 Latch BI 5 Override R5 R5-2 BI 5 Indicator BI 6 Latch BI 6 Override R6 R6-2 BI 6 Indicator BI 5 Smoke Alarm #1 BI 6 Smoke Alarm #2 · The RIBMNWLB-7-BC is set in Fan-Safety-Circuit mode by default from the factory. Fan-Safety-Circuit mode sets up BI 1 BI 6 in an AND function, so that when all 6 binary inputs are closed, BO 1 will close. Opening any of the 6 binary inputs will open BO 1. · BO 2 is bound to BI 7 such that when BI 7 is closed, BO 2 relay will activate. Binding and Priority level can be set by properties in BO 2. · The RIBMNWLB-7-BC can also be enabled as an I/O board with 2 binary output relays and 7 general-purpose binary inputs. RIBMNWLB-7-BC or RIBTWLB-7-BC Half-Wave Device 24 Vac 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 All other combinations = 9600 baud * 0 = Open ; 1 = Closed 134 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® SPECIALT Y PERIPHERAL CONTROLS FAN SAFETY ALARM CIRCUITS RIBMNLB-6/-4/-2 AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input, 6/4/2 Alarm Inputs all with N/C Outputs, 2.75" Track Mount Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc 3A Total Sourced from 24 Vac/dc Input R7 N/O POLE 2 R7 N/O POLE 1 R7 N/O POLE 1 R1 OUT N/C R1 R2 OUT N/C R2 R3 OUT N/C R3 R4 OUT N/C R4 R5 OUT N/C R5 COM N/O COM N/O R6 OUT N/C R6 R7 10A @ 277 Vac 10A @ 24 Vdc 1/2 HP @ 120/240 Vac B300 Pilot Duty Max. Isolated Dry Contact Output R1-R6 N/C INPUTS R1 R2 CLOSE OPEN R3 R4 CLOSE OPEN R5 R6 CLOSE OPEN 24 COM Vac/dc Alarm Input 1 Alarm Input 2 Alarm Input 3 Alarm Input 4 Alarm Input 5 Each Input Pulls 39mA from 24 V Input Alarm Input 6 4A Max Power Input Green LED 24 V Power Master Alarm Indicator SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Power Input: 4 Amp max. @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.20"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-6) 10A @ 277 Vac R7-2 4.60"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-4) (Typically used to shut down fan) 3.00"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-2) Hosuing Detail: See Housing H in housing guide for dimensions R7-1 Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided (RIBMNLB-6) 24 Vac (Typically used to shut down MT212-4 Mounting Track Provided other relays) (RIBMNLB-4, RIBMNLB-2) R1-2 Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS, CSFM Low Temp Alarm Gold Flash: No to DDC Controller Override Switch: No Notes: · Track mount models shown above. · RIBMNLB-6 has six Alarm Inputs and one Master Alarm. · RIBMNLB-4 has four Alarm Inputs and one Master Alarm. · RIBMNLB-2 has two Alarm Inputs and one Master Alarm. · This is a half wave device. When connecting 24Vac to both this device and a full wave device, damage to devices can occur. R2-2 High Temp Alarm to DDC Controller R3-2 Low Press Alarm to DDC Controller Models RIBMNLB-6, RIBMNLB-4, and RIBMNLB-2 are simply devices that combine a common relay-logic function into a small, easy-toinstall, and less expensive form. A master relay will open if any one of the normally-closed (N/C) inputs R4-2 open. There are six, four, or two inputs depending on the model High Press Alarm to DDC Controller chosen. LED status of all inputs, the master relay, and power input is provided. Bypass of un-used inputs is also provided. The RIBMNLB series is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB series is enclosed in a NEMA-1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The Smoke Alarm #1 R5-2 master relay has three general-purpose outputs: two 24 V output to DDC Controller terminals and one dry-contact output rated up to 10 Amp @ 277 Vac (terminals on RIBMNLB series, wires on RIBLB series.) The most com- mon application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure R6-2 outputs are provided so that a DDC controller can determine the Smoke Alarm #2 cause of a shutdown. to DDC Controller SELECTION GUIDE Model# Inputs RIBMNLB-6 6 MT212 Mounting Track RIBMNLB-4 4 MT212 Mounting Track RIBMNLB-2 2 MT212 Mounting Track 24 Vac Power Input R1-1 R2-1 R3-1 R4-1 R5-1 R6-1 R7 Close bypass switch if input not in use. Input 1 Bypass R1 R1-3 Input 1 Alarm Indicator Typical alarm inputs shown below. Any alarm inputs may be used and in any order. (Alarm inputs must be N/C.) Input 1 Low Temp Alarm Input 2 Bypass R2 R2-3 Input 2 Alarm Indicator Input 2 High Temp Alarm Input 3 Bypass R3 R3-3 Input 3 Alarm Indicator Input 3 Low Press Alarm Input 4 Bypass R4 R4-3 Input 4 Alarm Indicator Input 4 High Press Alarm Input 5 Bypass R5 R5-3 Input 5 Alarm Indicator Input 5 Smoke Alarm #1 Input 6 Bypass R6 R6-3 Input 6 Alarm Indicator RIBMNLB-6 (Track Mount) RIBLB-6 (Enclosed) Input 6 Smoke Alarm #2 (800) 888-5538 | www.functionaldevices.com 135 Power Input 24 Vac/dc Comm FAN SAFETY ALARM CIRCUIT RIBMNLB-1 General Purpose Latching Logic Circuit, One Latching/Fault Input, One Relay Output, 24 Vac/dc Power Input, 2.75" Track Mount Latch/Fault Input RESET Pushbutton Power Latch/Fault Status Status · MANUAL RESET · ONE ALARM OUTPUT · ONE RELAY OUTPUT N/C C N/O N/O C N/C SPECIALT Y PERIPHERAL CONTROLS SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Green LED: Power Status (ON: Power present) Red LED: Fault Status (ON: Latched/Fault State) Dimensions: 3.00"H x 2.75"W x 0.75"D1/1.25"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-4 Mounting Track Provided Approvals: CE, UL Listed, UL864, C-UL, RoHS, CSFM Gold Flash: No Relay Override Switch: No Fault Reset Switch: Yes Contact Ratings: 10 Amp Resistive @ 30Vdc 10 Amp General Use @ 277Vac 1/2 HP @ 120/240Vac (N/O) 1/3 HP @ 120/240Vac (N/C) Power Input Ratings: 53 mA @ 24Vac 25 mA @ 24Vdc 50/60 Hz H 24 Vac N Safety Latch Circuit Application LATCH RESET PB1 NC BI R LT-A BLK Auto-reset 24 VAC/DC H N L Power Indicator Fault Input Latch Circuit RIBMNLB-1 Circuit must latch on power up. Circuit must not relatch before or after fault has been cleared. Circuit must only relatch when power is reset. L Alarm Indicator LR1 LR1-1 LR1-2 LR1-3 LR1-4 Output Alarm Fault Application: When the Latch/Fault Input is Closed (Normal state), the Relay is activated, and Red LED is Off. When Latch/Fault Input Opens (Alarm state), the Relay deactivates, and Red LED turns On. Until the Latch/ Fault Input is Closed AND either power is cycled or the RESET button is pressed, relay will remain in the Alarm state. Notes: · Fault conditions must last for at least 500 ms in order for the unit to go into Alarm state. · Reset signal, whether via pushbutton or power cycling, must last for at least 30 ms in order to reset the device to go from Alarm state to Normal state. HP-A BI R 12 BLK P Man-reset LP-A BI R 12 BLK P Man-reset BI HT-A R 12 BLK Man-reset 24 VAC H N L Power Indicator R5-2 R5-3 L R1-1 R2-1 R3-1 R4-1 R5 R4-1 Fault Input 1 Input 1 Bypass Fault Input 2 Input 2 Bypass Fault Input 3 Input 3 Bypass Fault Input 4 Input 4 Bypass RIBMNLB-4 (ordered separately) R1 R1-3 L R1-2 R2 R2-3 L R2-2 R3 R3-3 L R3-2 R4 R4-3 L R4-2 Master Power Indicator Typically Used for Fan Shutdown 2046 BI BC LOCATED IN R EAD-ES BLK Alarm Indicator LT-A Status Alarm Indicator HP-A Status Alarm Indicator LP-A Status Alarm Indicator HT-A Status Typical Field Interlock Wiring 2046 DA 4054 AD 4054 AD LOCATED IN SUPPLY FAN MCC PANEL FAN #1. BO A1 SDR-1 A2 R BLK N.O. C 4054 CB LOCATED IN SUPPLY FAN MCC PANEL FAN #2. BO A1 SDR-1a A2 R BLK N.O. C 4054 CB LOCATED IN RETURN / EXHAUST FAN MCC PANEL FAN #1. 4055 AD BO A1 SDR-2 A2 R BLK 4055 CB N.O. C LOCATED IN RETURN / EXHAUST FAN MCC PANEL FAN #2. 4055 AD BO A1 SDR-2a A2 R BLK 4055 CB N.O. C 136 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® SPECIALT Y PERIPHERAL CONTROLS FAN SAFETY ALARM CIRCUITS RIBLB-6/-4/-2 AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input, 6/4/2 Alarm Inputs all with N/C Outputs, NEMA 1 Housing Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc 3A Total Sourced from 24 Vac/dc Input R7 N/O POLE 2 R7 N/O POLE 1 R7 N/O POLE 1 R1 OUT N/C R1 R2 OUT N/C R2 R3 OUT N/C R3 R4 OUT N/C R4 R5 OUT N/C R5 COM N/O COM N/O R6 OUT N/C R6 R7 10A @ 277 Vac 10A @ 24 Vdc 1/2 HP @ 120/240 Vac B300 Pilot Duty Max. Isolated Dry Contact Output R1-R6 N/C INPUTS R1 R2 CLOSE OPEN R3 R4 CLOSE OPEN R5 R6 CLOSE OPEN 24 COM Vac/dc Alarm Input 1 Alarm Input 2 Alarm Input 3 Alarm Input 4 Alarm Input 5 Each Input Pulls 39mA from 24 V Input Alarm Input 6 4A Max Power Input Green LED 24 V Power Master Alarm Indicator SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Power Input: 4 Amp max. @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 4.28H x 7.00W x 2.00D with .75 NPT Nipple Housing Detail: See Housing D in housing guide 10A @ 277 Vac (Typically used to R7-2 for dimensions shut down fan) Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided (RIBMNLB-6) R7-1 MT212-4 Mounting Track Provided 24 Vac (Typically used (RIBMNLB-4, RIBMNLB-2) to shut down Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS, CSFM other relays) Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, R1-2 UL Accepted for Use in Plenum Low Temp Alarm Gold Flash: No to DDC Controller Override Switch: No Notes: · Track mount models shown above. · RIBLB-6 have six Alarm Inputs and one Master Alarm. · RIBLB-4 have four Alarm Inputs and one Master Alarm. R2-2 High Temp Alarm to DDC Controller · RIBLB-2 have two Alarm Inputs and one Master Alarm. · This is a half wave device. When connecting 24Vac to both this device and a full wave device, damage to devices can occur. R3-2 Low Press Alarm Models RIBLB-6, RIBLB-4, and RIBLB-2 are simply devices that combine to DDC Controller a common relay-logic function into a small, easy-to-install, and less expensive form. A master relay will open if any one of the normally-closed (N/C) inputs open. There are six, four, or two inputs depending on the model High Press Alarm R4-2 chosen. LED status of all inputs, the master relay, and power input to DDC Controller is provided. Bypass of un-used inputs is also provided. The RIBMNLB series is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB series is enclosed in a NEMA-1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The R5-2 master relay has three general-purpose outputs: two 24 V output Smoke Alarm #1 terminals and one dry-contact output rated up to 10 Amp @ 277 Vac to DDC Controller (terminals on RIBMNLB series, wires on RIBLB series.) The most com- mon application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the R6-2 cause of a shutdown. Smoke Alarm #2 to DDC Controller SELECTION GUIDE Model# Inputs RIBLB-6 6 RIBLB-4 4 RIBLB-2 2 PE6020 Enclosure PE6020 Enclosure PE6020 Enclosure 24 Vac Power Input R1-1 R2-1 R3-1 R4-1 R5-1 R6-1 R7 Close bypass switch if input not in use. Input 1 Bypass R1 R1-3 Input 1 Alarm Indicator Typical alarm inputs shown below. Any alarm inputs may be used and in any order. (Alarm inputs must be N/C.) Input 1 Low Temp Alarm Input 2 Bypass R2 R2-3 Input 2 Alarm Indicator Input 2 High Temp Alarm Input 3 Bypass R3 R3-3 Input 3 Alarm Indicator Input 3 Low Press Alarm Input 4 Bypass R4 R4-3 Input 4 Alarm Indicator Input 4 High Press Alarm Input 5 Bypass R5 R5-3 Input 5 Alarm Indicator Input 5 Smoke Alarm #1 Input 6 Bypass R6 R6-3 Input 6 Alarm Indicator RIBMNLB-6 (Track Mount) RIBLB-6 (Enclosed) Input 6 Smoke Alarm #2 (800) 888-5538 | www.functionaldevices.com 137 SPECIALT Y PERIPHERAL CONTROLS To DDC Controller FAN SAFETY ALARM CIRCUITS RIBMNLB-6NO/-4NO/-2NO AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input, 6/4/2 Alarm Inputs all with N/O Outputs, 2.75" Track Mount 3A Total Sourced Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc from 24 Vac/dc Input or Dry Contact (Jumper Selectable) R1 OUT N/O R2 OUT N/O R3 OUT N/O R4 OUT N/O R5 OUT N/O R6 OUT N/O R7 R7 POLE 1 POLE 2 R1 R2 Alarm Input Indicators CLOSED 12 R3 R4 CLOSED 34 R5 R6 Master Relay R7 CLOSED 56 R1 R1 COM OPEN R2 R2 COM R3 R3 COM OPEN R4 R4 COM R5 R5 COM OPEN R6 R6 COM COMM 24V Alarm Input 1 Alarm Input 2 Alarm Input 3 Alarm Input 4 Alarm Input Bypass Switches Alarm Input 5 Alarm Input 6 4A Max Master Alarm Indicator 24V Power Legend for Jumper Selection Dry = 24V = SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Power Input: 4 Amp max. @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.20"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-6NO) 4.60"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-4NO) 3.00"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-2NO) Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided (RIBMNLB-6NO) MT212-4 Mounting Track Provided (RIBMNLB-4NO, RIBMNLB-2NO) Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS, CSFM Gold Flash: No Override Switch: No Input 1 24 Vac Input Power Comm 24 V R1-3 Input 2 R2-3 Input 3 R3-3 Input 4 24 Vac Preset Indicator R1 R1 Alarm Indicator R2 R2 Alarm Indicator R3 R3 Alarm Indicator R1-2 R4 R2-2 Models RIBMNLB-6NO, RIBMNLB-4NO, and RIBMNLB-2NO are simply devices that combine a common relay-logic function into a small, easy-to-install, and less expensive form. A master relay will open if any one of the normally-closed (N/C) inputs open. There are six, four, or two inputs depending on the model chosen. LED status of all inputs, the master relay, and power input is provided. Bypass of un-used inputs is also provided. The RIBMNLB series is provided with mounting track for mounting in user-provided electrical enclosures. Input 5 Input 6 R4-3 R4 Alarm Indicator R5 R3-2 R5-3 R5 Alarm Indicator R4-2 R6 R6-3 R6 Alarm Indicator R5-2 R1-1 R2-1 R3-1 R4-1 R5-1 R6-1 R7 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 R6-2 Bypass Bypass Bypass Bypass Bypass Bypass The master relay has two general-purpose outputs: both can be jumper selected at 24 V (sourced from input) or dry contact. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown. R7-3 R7-1 Output Con guration Jumper Dry Contact Wet Contact P1 P2 P3 P4 R7 Alarm Indicator Notes: · RIBMNLB-6NO has six Alarm Inputs and one Master Alarm. · RIBMNLB-4NO has four Alarm Inputs and one Master Alarm. · RIBMNLB-2NO has two Alarm Inputs and one Master Alarm. · This is a half wave device. When connecting 24 Vac to both this device and a full-wave device, damage to device can occur. R7-2 Output Con guration Jumper R7-1 Dry Contact Wet Contact P5 P6 P7 P8 SELECTION GUIDE Model# Inputs RIBMNLB-6NO 6 MT212 Mounting Track RIBMNLB-4NO 4 MT212 Mounting Track RIBMNLB-2NO 2 MT212 Mounting Track R7-2 RIBMNLB-6NO 138 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® I/O EXPANDER RIBMN24Q2C I/O Expander, 2 Outputs, 24 Vac/ dc Power Input, 0-10 Vdc / 0-5 Vdc Control Input, 2.75"Track Mount AI Com 0-10 Vdc / 0-5 Vdc 24 Vac/dc Comm * Relay 1 Relay 2 0-10 VDC CONTROL VOLTAGE 0-2.117Vdc 0-5 VDC * CONTROL VOLTAGE 0-1.058Vdc RELAY 1 STATUS OFF RELAY 2 STATUS OFF 2.745-4.627Vdc 1.373-2.313Vdc ON OFF 5.255-7.137Vdc 2.628-3.568Vdc OFF ON 7.765-10.000Vdc 3.883-5.000Vdc ON ON N/O C N/C N/O C N/C SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 3.10"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-4 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No I/O EXPANDER GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS, OR MULTI-STAGE HEATING Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 100mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders. RIBMN24Q3C I/O Expander, 3 Outputs, 24 Vac/dc Power Input, 0-10 Vdc / 0-5 Vdc Control Input, 2.75" Track Mount SPECIALT Y PERIPHERAL CONTROLS AI Com 0-10 Vdc / 0-5 Vdc 24 Vac/dc Comm 0-10 VDC 0-5 VDC * RELAY RELAY RELAY CONTROL CONTROL 1 2 3 VOLTAGE VOLTAGE STATUS STATUS STATUS * 0-0.988Vdc 0-0.494Vdc OFF OFF OFF 1.366-2.242Vdc 0.683-1.121Vdc ON OFF OFF 2.620-3.496Vdc 1.310-1.748Vdc OFF ON OFF Relay 1 Relay 2 Relay 3 3.876-4.752Vdc 1.938-2.376Vdc ON ON OFF 5.130-6.006Vdc 2.565-3.003Vdc OFF OFF ON N/O C N/C SPECIFICATIONS N/C C N/O N/O C N/C 6.386-7.262Vdc 3.193-3.631Vdc ON OFF ON 7.640-8.516Vdc 3.820-4.258Vdc OFF ON ON GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS, 8.896-10.000Vdc 4.448-5.000Vdc ON ON ON OR MULTI-STAGE HEATING # Relays & Contact Type: Three (3) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 4.00"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-4 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 150mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders. (800) 888-5538 | www.functionaldevices.com 139 SPECIALT Y PERIPHERAL CONTROLS I/O EXPANDER RIBMN24Q4C I/O Expander, Four Outputs, 24 Vac/dc Power, 0-10 Vdc / 0-5 Vdc Control Input, 2.75" Track Mount 0-10 VDC CONTROL VOLTAGE 0-0.372Vdc 0-5 VDC * CONTROL VOLTAGE 0-0.186Vdc RELAY RELAY RELAY RELAY 1 2 3 4 STATUS STATUS STATUS STATUS OFF OFF OFF OFF AI Com 0-10 Vdc / 0-5 Vdc 24 Vac/dc Comm 0.726-1.000Vdc 0.363-0.500Vdc ON OFF OFF OFF 1.354-1.626Vdc 0.677-0.813Vdc OFF ON OFF OFF 1.982-2.254Vdc 0.991-1.127Vdc ON ON OFF OFF * 2.608-2.882Vdc 1.304-1.441Vdc OFF OFF ON OFF 3.236-3.508Vdc 1.618-1.754Vdc ON OFF ON OFF 3.864-4.136Vdc 1.932-2.068Vdc OFF ON ON OFF Relay 1 Relay 2 Relay 3 Relay 4 4.492-4.764Vdc 2.246-2.382Vdc ON ON ON OFF 5.118-5.392Vdc 2.559-2.696Vdc OFF OFF OFF ON 5.746-6.018Vdc 2.873-3.009Vdc ON OFF OFF ON 6.374-6.646Vdc 3.187-3.323Vdc OFF ON OFF ON N/C C N/O N/C C N/O N/C C N/O N/C C N/O 7.000-7.274Vdc 3.500-3.637Vdc ON ON OFF ON 7.628-7.902Vdc 3.814-3.951Vdc OFF OFF ON ON 8.256-8.528Vdc 4.128-4.264Vdc ON OFF ON ON 8.884-9.156Vdc 4.442-4.578Vdc OFF ON ON ON SPECIFICATIONS 9.510-10.000Vdc 4.755-5.000Vdc # Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 4.95"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Origin: Made of US and non-US parts ON ON ON ON Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS, OR MULTI-STAGE HEATING Power Input: 24 Vac/dc ; 50-60 Hz 200mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders. I/O EXPANDER RIBMN24Q4C-PX Field Adjustable Staging Threshold Relay Module, 4 Outputs, 24 Vac/dc Power Input, 0-10 Vdc Control Input, 2.75" Track Mount 24 Vac/dc Comm Power }Input Setup Display DN UP Relay 1 Relay 2 Relay 3 Relay 4 N/O N/C C N/O N/C C N/O N/C C N/O SPECIFICATIONS N/C C Analog }Input (+) AI Com () 0-10 Vdc · CONTROL FOUR RELAY OUTPUTS WITH ONE (0-10 VDC) ANALOG SIGNAL FROM CONTROLLER OR THERMOSTAT · CAPABILITY TO SET DESIRED ON AND OFF VOLTAGES FOR EACH RELAY · NO POTS TO ADJUST · NO NEED FOR VOLT METER FOR SETUP · ON BOARD "FIELD SELECTABLE" DIGITAL DISPLAY # Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Heartbeat Status: Right-most decimal point Dimensions: 4.95"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 200mA max. Notes: · For AC applications, an isolation transformer, to be used solely for the power input, is recommended. · Relay will activate when control signal voltage reaches or exceeds individual relay ON point. Relay will deactivate when control voltage reaches or drops below individual OFF point. · Factory relay ON / OFF voltages: · Relay 1: 3V / 2.8V · Relay 2: 5V / 4.8V · Relay 3: 7V / 6.8V · Relay 4: 9V / 8.8 V · Minimum ON point: 0.5V · Maximum ON point: 9.9V · Minimum OFF point: 0.3V · Relay number will flash 3 times when voltage exceeds setpoint. · Pressing UP or DN button in normal run mode will display the voltage present on Analog Input. · ON/OFF points can be changed at any time, by the user, by entering "Program Mode" · User defined ON/OFF points will be maintained upon power loss. 140 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® MANUAL ANALOG OVERRIDE SWITCH RIBMNA1D0 Manual Analog Override Switch + Monitor, 24 Vac/dc Power Input, 2.75" Track Mount Signal + Signal Power Power + Manual Auto 80% 60% 40% 20% + Potentiometer Output + Output Feedback Legend for Selecting Output for Jumpers Top 2 pins covered by jumper Bottom 2 pins covered by jumper Only 1 pin covered by jumper 5 Vdc 10 Vdc 15 Vdc 20 mA SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 2.45"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750", MT212 Mounting Track Sold Separately Input Voltage: 24 Vac/dc Input Current: 90mA Max. Range/Impedance Override: 0-5 Vdc, 200 Min. 0-10 Vdc, 400 Min. 0-15 Vdc, 1 k Min. 0-20mA dc, 500 Max. Feedback Contact: 2A Max. @ 24 Vac/dc Notes: · Set the jumpers according to your input signal (Analog signal from the controller.) Example: When controlling a damper with 0-10 Vdc, the jumpers need to be in position for the 0-10 Vdc override range. If the LED range does not match your analog scale, ensure the jumpers are set for the proper range. · Feedback contact closed when switch is in Manual position, open when switch is in Auto position. · PROVIDES MANUAL OVERRIDE IF CONTROLLER DOES NOT SUPPORT OVERRIDE CAPABILITY · ALLOWS YOU TO MANUALLY MAKE ADJUSTMENTS TO YOUR END DEVICE REMOTELY INSTEAD OF AT YOUR CONTROL PANEL · SENDS OVERRIDE STATUS BACK TO CONTROLLER VIA FEEDBACK · MULTI-RANGE ANALOG OUTPUT SPECIALT Y PERIPHERAL CONTROLS (800) 888-5538 | www.functionaldevices.com 141 INTELLIGENT FIELD DEVICES RIBTW2402B-BC RIBTWX2401B-BC RIBMNWD12-BC INTELLIGENT FIELD DEVICES RIBMNWX2401B-BC RIBMW24B-44-BC INTELLIGIENT FIELD DEVICES Our Intelligent Field Devices can be hard wired and used instead of more expensive multioutput controllers when a few more control points are needed, and large controllers are too much for the job. They can also be used when control points are widely spread throughout the job site. These devices have been prepackaged to save the installer the time, trouble, and expense of buying separate components and assembling them on the job. Product Features · BACnet® and Modbus protocols · Analog input · Analog output · Binary output · Binary input · Thermistor inputs available · On-board current sensors available · Track mount and enclosed versions · NEMA 4X available · UL Listed 142 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® INTELLIGENT FIELD DEVICES BACNET® DEVICES POWER INPUT CONTACT RATINGS MODEL # RELAY CONAC/DC AC TACTS RESISTIVE MOTOR PILOT DUTY DRY TRACK CONTACT ACCUMU- INTERNAL PRECON® MOUNT / BINARY ANALOG ANALOG LATOR CURRENT THERMISTOR OVERRIDE HOUSING INPUT INPUT OUTPUT INPUT SENSOR INPUT SWITCH STYLE * SPEC PAGE RIBTW2401B-BC · 24 120 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 1 # C 144 RIBTW2402B-BC · 24 208-277 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 1 # C 145 RIBMNWX2401B-BC · 24 120 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 1 · # MT212-6 146 RIBTWX2401B-BC · 24 120 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 1 · # D 147 RIBMNWX2402B-BC · 24 208-277 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 1 · # MT212-6 148 RIBTWX2402B-BC · 24 208-277 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 1 · # D 149 RIBMNW24B-BCAI · 24 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 2 1 10k Type 2 or 3 # MT212-6 150 RIBTW24B-BCAI · 24 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 2 1 10k Type 2 or 3 # D 151 RIBTW24B-BCAO · 24 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 1 1 1 10k Type 2 or 3 # D 152 RIBMNWD12-BCDI 24 12 MT212-6 153 RIBMNWD12-BC 24 12 2 RIBMW24B-44-BC · 24 4 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac 4 MT212-6 154 # MT4-6 155 OTHER BACNET® DEVICES: Fan Safety Alarm Circuit / General Purpose Logic Board (pg. 137) and UPS Kit (pg. 174) MODBUS DEVICES POWER INPUT CONTACT RATINGS MODEL # RELAY AC/DC AC CONTACTS RESISTIVE MOTOR PILOT DUTY PRECON® DRY CONTACT ANALOG THERMISTOR OVERRIDE TRACK MOUNT / BINARY INPUT INPUT INPUT SWITCH HOUSING STYLE * SPEC PAGE RIBMNW24B-MBAI · 24 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 2 1 10k Type 2 # MT212-6 156 RIBTW24B-MBAI · 24 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac 2 1 10k Type 2 # D 157 = UL Listed - see data sheet for specific Listing # = Coil Side Relay Override (requires unit to be powered) = UL Component Recognized - see data sheet for specific Listing * = See Housing Guide on page 201 ^ = Track mount included INTELLIGENT FIELD DEVICES (800) 888-5538 | www.functionaldevices.com 143 INTELLIGENT FIELD DEVICE RIBTW2401B-BC BACnet MS/TP Network Relay Device, One Binary Output + Override, One Binary Input, 24 Vac/dc/120 Vac Power Input, NEMA 1 Housing Dry Contact Binary Input REF A() B(+) MSB LSB Baud Rate Relay Override } } MSTP 0 1 1 2 3 4 5 6 7 8 9 10 11 12 24 Vac/dc Comm MS/TP ADDRESS Connect Jumper for EOL. Disconnect for no terminating resistor. INTELLIGENT FIELD DEVICES Wht/Yel Wht/Blk Blu Yel Org Neutral 120 Vac N/C C N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Communication Red LED: Relay Status Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the M S/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: BACnet® Details: 20 Amp Resistive @ 277 Vac · MS/TP Address & Baud Rate must be set 20 Amp Ballast @ 277 Vac prior to power up via DIP switches. 16 Amp Electronic Ballast @ 277 Vac (N/O) · Device ID will default to 277XXX where 10 Amp Tungsten @ 120 Vac (N/O) XXX is the MS/TP Address. 1110 VA Pilot Duty @ 277 Vac Examples: 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Power Input Ratings: Device ID - 277121 81 mA @ 24 Vdc · Device ID can be changed via network 111 mA @ 24 Vac command. Once changed, it will no longer 96 mA @ 120 Vac default to 277XXX. (MS/TP Address & Device ID must be unique.) Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input). · Device Instance changed via Object Identifier Property of Device Object Notes: · PIC Statement available on website. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 All other combinations=9600 baud BAUD RATE 9600 19200 38400 57600 76800 115200 DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBTW2401B-BC or RIBTW2402B-BC Half-Wave Device 24 Vac 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). 144 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® INTELLIGENT FIELD DEVICE RIBTW2402B-BC BACnet MS/TP Network Relay Device, One Binary Output + Override, One Binary Input, 24Vac/dc/208-277Vac Power Input, NEMA 1 Housing } } MSTP 0 1 1 2 3 4 5 6 7 8 9 10 11 12 24 Vac/dc Comm MS/TP ADDRESS Connect Jumper for EOL. Disconnect for no terminating resistor. Dry Contact Binary Input REF A() B(+) MSB LSB Baud Rate Relay Override INTELLIGENT FIELD DEVICES Wht/Yel Wht/Brn Blu Yel Org Neutral 208-277 Vac N/C C N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Communication Red LED: Relay Status Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac 121 mA @ 208-277 Vac Power Input: 24 Vac/dc ; 208-277 Vac ; 50/60 Hz Notes: · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input). · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 All other combinations=9600 baud BAUD RATE 9600 19200 38400 57600 76800 115200 24 Vac DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBTW2401B-BC or RIBTW2402B-BC Half-Wave Device 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). (800) 888-5538 | www.functionaldevices.com 145 INTELLIGENT FIELD DEVICE - RELAY / CURRENT SENSOR COMBO RIBMNWX2401B-BC BACnet MS/TP Network Relay Device, One Binary Output + Override, Two Binary Inputs (One Current Sensor Relay Load Sensing & One Dry Contact Binary Input), 24Vac/dc/120 Vac Power Input, 2.75"Track Mount } Dry Contact Binary Input } } 1 2 3 4 5 6 7 8 9 10 11 12 1 0 Relay Override Baud Rate LSB MSB MS/TP ADDRESS Connect Jumper for EOL. Disconnect for no terminating resistor. MSTP A() B(+) REF Red LED=Relay Status Green LED=Network Communication Pink LED=Current Sensor Status Pink LED=Binary Input Status Low Voltage } Power Input High Voltage } Power Input C Contacts N/O Internal N/C Current Sensor Neutral 120 Vac 24 Vac/dc Comm INTELLIGENT FIELD DEVICES SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS, BTL Certified Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 All other combinations=9600 baud BAUD RATE 9600 19200 38400 57600 76800 115200 Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 105 mA @ 120 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. Notes: · Device can be powered by either 24 Vac/dc or 120 Vac, but not both. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBMNWX2401B-BC or RIBTWX2401B-BC Half-Wave Device 24 Vac 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). 146 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® INTELLIGENT FIELD DEVICE - RELAY / CURRENT SENSOR COMBO RIBTWX2401B-BC BACnet MS/TP Network Relay Device, One Binary Output + Override, Two Binary Inputs (One Current Sensor Relay Load Sensing & One Dry Contact Digital Input), 24 Vac/dc/120 Vac Power Input, NEMA 1 Housing } Dry Contact Binary Input } } 1 2 3 4 5 6 7 8 9 10 11 12 1 0 Relay Override Baud Rate LSB MSB MS/TP ADDRESS Connect Jumper for EOL. Disconnect for no terminating resistor. MSTP A() B(+) REF Red LED=Relay Status Green LED=Network Communication Pink LED=Current Sensor Status Pink LED=Binary Input Status Low Voltage } Power Input High Voltage } Power Input C Contacts N/O Internal N/C Current Sensor Neutral 120 Vac 24 Vac/dc Comm INTELLIGENT FIELD DEVICES SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS, BTL Certified Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 All other combinations=9600 baud Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 105 mA @ 120 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. Notes: · Device can be powered by either 24 Vac/dc or 120 Vac, but not both. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2401B-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2401B-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2401B-BC-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. DIP SWITCHES* 11 12 1 0 X 1 0 0 RELAY STATE** Auto Override on Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBMNWX2401B-BC or RIBTWX2401B-BC Half-Wave Device 24 Vac 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). (800) 888-5538 | www.functionaldevices.com 147 INTELLIGENT FIELD DEVICES INTELLIGENT FIELD DEVICE - RELAY / CURRENT SENSOR COMBO RIBMNWX2402B-BC BACnet MS/TP Network Relay Device, One Binary Output + Override, Two Binary Inputs (One Current Sensor Relay Load Sensing & One Dry Contact Digital Input), 24 Vac/dc or 208-277 Vac Power Input, 2.75"Track Mount } Dry Contact Binary Input } } 1 2 3 4 5 6 7 8 9 10 11 12 1 0 Relay Override Baud Rate LSB MSB MS/TP ADDRESS MSTP Connect Jumper for EOL. Disconnect for no terminating resistor. A() B(+) REF Red LED=Relay Status Green LED=Network Communication Pink LED=Current Sensor Status Pink LED=Binary Input Status Low Voltage } Power Input High Voltage } Power Input C Contacts N/O Internal N/C Current Sensor Neutral 208-277 Vac 24 Vac/dc Comm SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS, BTL Certified Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 All other combinations=9600 baud BAUD RATE 9600 19200 38400 57600 76800 115200 DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. 24 Vac Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 24 Vac/dc ; 208-277 Vac ; 50/60 Hz Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 120 mA @ 208-277 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. Notes: · Device can be powered by either 24 Vac/dc or 208-277 Vac, but not both. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. RIBMNWX2402B-BC or RIBTWX2402B-BC Half-Wave Device 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). 148 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® INTELLIGENT FIELD DEVICES INTELLIGENT FIELD DEVICE - RELAY / CURRENT SENSOR COMBO RIBTWX2402B-BC BACnet MS/TP Network Relay Device, One Binary Output + Override, Two Binary Inputs (One Current Sensor Relay Load Sensing & One Dry Contact Binary Input), 24Vac/dc/208-277Vac Power Input, NEMA 1 Housing } Dry Contact Binary Input } } 1 2 3 4 5 6 7 8 9 10 11 12 1 0 Relay Override Baud Rate LSB MSB MS/TP ADDRESS MSTP Connect Jumper for EOL. Disconnect for no terminating resistor. A() B(+) REF Red LED=Relay Status Green LED=Network Communication Pink LED=Current Sensor Status Pink LED=Binary Input Status Low Voltage } Power Input High Voltage } Power Input C Contacts N/O Internal N/C Current Sensor Neutral 208-277 Vac 24 Vac/dc Comm SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS, BTL Certified Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 24 Vac/dc ; 208-277 Vac ; 50/60 Hz Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 120 mA @ 208-277 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 All other combinations=9600 baud BAUD RATE 9600 19200 38400 57600 76800 115200 Notes: · Device can be powered by either 24 Vac/dc or 208-277 Vac, but not both. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2402B-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2402B-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2402B-BC-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBMNWX2402B-BC or RIBTWX2402B-BC Half-Wave Device 24 Vac 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). (800) 888-5538 | www.functionaldevices.com 149 INTELLIGENT FIELD DEVICES INTELLIGENT FIELD DEVICE RIBMNW24B-BCAI BACnet MS/TP Network Relay Device with Binary Output Set Point, One Binary Output + Override, Two Binary Inputs, One Analog Input, 24 Vac/dc Power Input, 2.75"Track Mount 5V 10 V 1 2 A() B(+) REF MS/TP ^See EOL Resistor jumper 1 0 ^To select AI OPEN for Thermistor AI Voltage T2 or T3 input. Install jumper Select ^# Switch Connect Jumper for EOL. Disconnect for no terminating resistor 1 2 3 4 5 6 7 8 9 10 11 12 RELAY CONTROL BAUD RATE LSB MS/TP ADDRESS MSB Analog Type Jumpers OFF OFF Not de ned OFF ON T2 Thermistor ON OFF T3 Thermistor ON ON Analog IN 5V or 10V AI A1 COM Therm. +5V Analog In Close only one) 5V SW1 Closed SW2 Open 10V SW1 Open SW2 Closed Thermistor T2 or T3 input, use 5V selection 24 Vac/dv} Comm N/C Green LED - Network Status Red LED - Relay Status Pink LED - B1 1 Status Pink LED - B1 2 Status BI 1 COM BI 1 BI 2 COM BI 2 Relay N/O Contacts C Code Version 1.5 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated BI1 Status: Pink LED On = Activated BI2 Status: Pink LED On = Activated Dimensions: 5.68"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS, BTL Certified Gold Flash: No Relay Override Switch: DIP Switch Control (See Bulletin B1243) Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable - See Bulletin B1243) Sensor 0-5Vdc, 0-10Vdc or T2/T3 Thermistor Set Point Function for App. Version 1.5 or higher BCAI BI1 BI2 BO1 AI1 Logic Set Point Differential Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Notes: · For all versions, raw analog default settings are 0 and 1023 (real), respectively. Units default to 95 (no units). For Set Point Function settings, See Bulletin B1243 · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, (See Bulletin B1243 for diagram) Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac · PIC Statement available on website. BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Dry contact binary input), AI 1 (Analog input), AV1 (Set Point), AV2 (Differential), BV1 (Function Enable), BV2 (Function Mode), BV3 (Function Status) · Device Instance changed via Object Identifier Property of Device Object Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included. Network · For both T2 and T3, MIN_PRES_VAL must be set to -36 (real value) and MAX_PRES_VAL must be set to 66.3 (real value) for Celcius. For Fahrenheit, MIN_PRES_VAL must be set to -32.8 (real value) and MAX_PRES_VAL must be set to 151.34 (real value). · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps Set Point Function must be enabled via the Network for logic to execute. Once configured, the function will continue to operate even if communication is lost (see Bulletin B1243 for setup). 150 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® INTELLIGENT FIELD DEVICES INTELLIGENT FIELD DEVICE RIBTW24B-BCAI BACnet MS/TP Network Relay Device with Binary Output Set Point, One Binary Output + Override, Two Binary Inputs, One Analog Input, 24 Vac/dc Power Input, NEMA 1 Housing 5V 10 V 1 2 A() B(+) REF MS/TP ^See EOL Resistor jumper 1 0 ^To select AI OPEN AI Voltage Select ^# Switch for Thermistor T2 or T3 input. Install jumper Connect Jumper for EOL. Disconnect for no terminating resistor 1 2 3 4 5 6 7 8 9 10 11 12 RELAY CONTROL BAUD RATE LSB MS/TP ADDRESS MSB Analog Type Jumpers OFF OFF Not de ned OFF ON T2 Thermistor ON OFF T3 Thermistor ON ON Analog IN 5V or 10V AI A1 COM Therm. +5V Analog In Close only one) 5V SW1 Closed SW2 Open 10V SW1 Open SW2 Closed Thermistor T2 or T3 input, use 5V selection 24 Vac/dv} Comm N/C Green LED - Network Status Red LED - Relay Status Pink LED - B1 1 Status Pink LED - B1 2 Status BI 1 COM BI 1 BI 2 COM BI 2 N/O Relay Contacts C Code Version 1.5 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated BI1 Status: Pink LED On = Activated BI2 Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control (See Bulletin B1243) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac · PIC Statement available on website. Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable - See Bulletin B1243) Sensor 0-5Vdc, 0-10Vdc or T2/T3 Thermistor Set Point Function for App. Version 1.5 or higher BCAI BI1 BI2 BO1 AI1 Logic Set Point Differential Network Notes: · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24B-BCAI-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTW24B-BCAI-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTW24B-BCAI-N4-GY) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. Units default to 95 (no units). For Set Point Function settings, See Bulletin B1243 · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, (See Bulletin B1243 for diagram) BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Dry contact binary input), AI 1 (Analog input), AV1 (Set Point), AV2 (Differential), BV1 (Function Enable), BV2 (Function Mode), BV3 (Function Status) · Device Instance changed via Object Identifier Property of Device Object Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included. · For both T2 and T3, MIN_PRES_VAL must be set to -36 (real value) and MAX_PRES_VAL must be set to 66.3 (real value) for Celcius. For Fahrenheit, MIN_PRES_VAL must be set to -32.8 (real value) and MAX_PRES_VAL must be set to 151.34 (real value). · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps Set Point Function must be enabled via the Network for logic to execute. Once configured, the function will continue to operate even if communication is lost (see Bulletin B1243 for setup). (800) 888-5538 | www.functionaldevices.com 151 INTELLIGENT FIELD DEVICES INTELLIGENT FIELD DEVICE RIBTW24B-BCAO BACnet MS/TP Network Relay Device, One Binary Output + Override, One Binary Input, One Analog Output, One Analog Input, 24Vac/dc Power Input, NEMA 1 Housing A() B(+) REF LSB AI COM AI Therm. +5V 24 Vac/dc Power MS/TP Thermistor Select RELAY CONTROL 10 V 5 V 1 2 1 2 3 4 5 6 7 8 9 10 11 12 OPEN MSB MS/TP ADDRESS BAUD RATE AI Voltage Select Switch J1: Jumper for EOL resistor Green LED=Network Status Red LED=Relay Status J5: Install for 0-10 V J2 J3 Analog In ON ON T3 Thermistor ON OFF T2 Thermistor OFF ON Not de ned OFF OFF () (+) Dry Contact BI COM () Binary Input B I (+) N/C N/O C Pink LED=BI Status Relay Contacts } Analog Output 4-20 mA Analog Output 0-5 Vdc 0-10 Vdc Shown With Cover SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Relay Activated Binary Input Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin:: Made of US and non-US parts Approvals: UL Listed, UL916, C-UL, RoHS, BTL Certified Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Gold Flash: No Relay Override: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Magnetic Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 176 mA @ 24 Vac 150 mA @ 24 Vdc Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included. · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps BACnet® Details: · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), AI 1 (Analog input), AO 1 (Analog output) Notes: · PIC Statement available on website. · Use a separate 24 Vac transformer, or an isolated 24 Vdc power supply to power-up this product. · Addressing Specifications: Bulletin B2028 available on website. · Complete Installation Instructions: Bulletin B1756 available on website. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Analog Output Voltage (0-5 Vdc; 0-10 Vdc) Analog Output Current (4-20 mA) ANALOG OUTPUT ACCURACY AS A FUNCTION OF OUTPUT SPAN (USING STANDARD CONDITIONS *) Span 20% - 100% Span 10% - 100% Span 0% - 100% +/- 2% error +/- 5% error +/- 11% error +/- 2% error +/- 3% error +/- 12% error * Standard Conditions: Power Supply Input: 22 Vac/dc to 28 Vac/dc ; Loop Resistance (Analog Output 4-20 mA Loop): 530 Ohms max. Load Resistance [Analog Output Voltage (0-5 Vdc, 0-10 Vdc)]: 10 K Ohms min. ; Ambient Temperature: -30 to 140° F 0-5Vdc or 0-10 Vdc Temperature, Humidity, Pressure Transducer AI AI Com Analog 10K Input RIBTW24B-BCAO Half-Wave Device 24 Vac 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). 152 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® INTELLIGENT FIELD DEVICE RIBMNWD12-BCDI BACnet MS/TP Network Input Device, Twelve Binary Inputs (Voltage or Dry Contacts), 2.75"Track Mount } } } } } } } } 24 Vac/dc MSTP BI 1 BI 2 BI 3 BI 4 BI 5 BI 6 A() B(+) REF +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM Connect Jumper for terminating resistor. Disconnect for no terminating resistor. Pink LEDs = Digital Input Status Connect Jumper for Dry Contact Operation. Disconnect for voltage input operation. Green LED = Network Communication Red LED = Power } } } } } } Not Used Baud Rate LSB MSB 1 2 3 4 5 6 7 8 9 10 MS/TP ADDRESS COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V BI 12 BI 11 BI 10 BI 9 BI 8 BI 7 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Green LED: Network Communication Red LED: ON = Power Present Dimensions: 6.00"H x 2.75"W x 1.25"D1/1.75"D2 Origin: See Housing H in housing guide for dimensions Track Mount: Made of US and non-US parts Approvals: MT212-6 Mounting Track Provided CE, RoHS, BTL Certified Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Band Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Power Input Ratings: 41 mA @ 24 Vdc 53 mA @ 24 Vac Binary Input Ratings: Dry Contact: 3 mA @ 30 Vdc max. Voltage Input: 12 mA @ 25 Vac/dc max. BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Device Instance changed via Object Identifier Property of Device Object · Full wave rectified · PIC Statement available on website. · Objects included in device are: BI 1 (Binary input) BI 7 (Binary input) BI 2 (Binary input) BI 8 (Binary input) BI 3 (Binary input) BI 9 (Binary input) BI 4 (Binary input) BI 10 (Binary input) BI 5 (Binary input) BI 11 (Binary input) BI 6 (Binary input) BI 12 (Binary input) DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 * 0 = Open ; 1 = Closed All other combinations=9600 baud Example of Dry Contact Input Operation Example of Voltage Input Operation Dry Contact N/C +V Vin COM Voltage Source + +V Vin COM Jumper Connected Jumper Disconnected INTELLIGENT FIELD DEVICES (800) 888-5538 | www.functionaldevices.com 153 INTELLIGENT FIELD DEVICE RIBMNWD12-BC BACnet MS/TP Network Input Device, Twelve Binary Inputs (Voltage or Dry Contacts), Accumulators, 2.75"Track Mount MSTP BI 1/ACC1 BI 2/ACC2 BI 3 BI 4 BI 5 BI 6 24 Vac/dc A() B(+) REF +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM } } } } } } } } Connect Jumper for EOL. Disconnect for no terminating resistor. Pink LEDs = Digital Input Status Connect Jumper for Dry Contact Operation. Disconnect for voltage input operation. Green LED = Network Communication Red LED = Power } } } } } } Not Used Baud Rate LSB MSB 1 2 3 4 5 6 7 8 9 10 MS/TP ADDRESS COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V BI 12 BI 11 BI 10 BI 9 BI 8 BI 7 TWO (ACCUMULATOR) INPUTS CAN BE USED FOR POWER MONITORING OR OTHER PULSE COUNTING APPLICATION. SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Green LED: Network Communication Red LED: ON = Power Present Dimensions 6.00"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, RoHS, BTL Certified Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Power Input Ratings: 41 mA @ 24 Vdc 53 mA @ 24 Vac Max. Accumulator Frequency: 50 Hz BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. Binary Input Ratings: Dry Contact: 3 mA @ 30 Vdc max. Voltage Input: 12 mA @ 25 Vac/dc max. · Objects included in device are: } BI 1 (Binary input) Use Same ACC 1 (Accumulator) Physical Input } BI 2 (Binary input) Use Same ACC 2 (Accumulator) Physical Input BI 3 (Binary input) BI 4 (Binary input) BI 5 (Binary input) BI 6 (Binary input) BI 7 (Binary input) BI 8 (Binary input) BI 9 (Binary input) BI 10 (Binary input) BI 11 (Binary input) BI 12 (Binary input) DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 * 0 = Open ; 1 = Closed All other combinations=9600 baud Example of Dry Contact Input Operation Example of Voltage Input Operation Dry Contact N/C +V Vin COM Voltage Source + +V Vin COM Jumper Connected Jumper Disconnected INTELLIGENT FIELD DEVICES 154 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® BO1 C BO1 N/O BO1 N/C BO2 C BO2 N/O BO2 N/C INTELLIGENT FIELD DEVICE RIBMW24B-44-BC BACnet MS/TP Network Relay Device, Four Binary Outputs + Override, Four Binary Inputs, 24 Vac/dc Power Input, 4.00"Track Mount REF B(+) A() MSTP 1 0 Baud Rate LSB MSB DIP 1 1 2 3 4 5 6 7 8 9 10 DIP 2 12345678 MS/TP ADDRESS BO1 BO2 RELAY OVERRIDE Connect Jumper Red LEDs BO3 BO4 for terminating resistor. Disconnect for no terminating resistor. Network Status Green LED Pink LEDs BI1 BI2 BI3 BI4 Power Input Relay 1 Contacts Relay 2 Contacts Relay 3 Contacts Relay 4 Contacts BO3 N/C BO3 N/O BO3 C BO4 N/C BO4 N/O BO4 C BI1 COM BI1 BI2 COM BI2 BI3 COM BI3 BI4 COM BI4 24 Vac/dc Comm SPECIFICATIONS # Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00"H x 4.00"W x 0.88"D1/1.38"D2 Housing Detail: See Housing H in housing guide for dimensions Origin:: Made of US and non-US parts Track Mount: MT4-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS, BTL Certified Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (Dip Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 24 Vac : 400 mA 24 Vdc : 190 mA BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique) · This model utilizes: BO1, BO2, BO3, BO4, (Relay outputs), BI1, BI2, BI3, BI4 (Dry contact inputs) · Device Instance changed via Object Identifier Property of Device Object · Each unit is 1/8 unit load · PIC Statement available on website. DIP 1 DIP 2 DIP Switches 1-7 8 9 10 0 0 0 0 0 1 See Bulletin B1082 for 0 1 0 full MS/TP 0 1 1 Addressing 1 0 0 1 0 1 All other combinations=9600 baud Baud Rate 9600 19200 38400 57600 76800 115200 · Dry contact digital input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. Relay BO1 BO2 BO3 BO4 Relay State** Auto ON OFF Auto ON OFF Auto ON OFF Auto ON OFF 1 2 1 X X X 0 X X 1 X X X 0 X X X X X X X X X X X X DIP Switches* 3 4 5 6 7 8 X X 0 X X X X X 1 X X X X X 0 X X X X X X 0 X X X X X 1 X X X X X 0 X X 1 X X X 0 X X X X X 1 X 0 X X X 0 X X 1 X X X 0 X X X X X 1 X 0 X X X 0 * 0 = Open ; 1 = Closed ** Device must be powered for override INTELLIGENT FIELD DEVICES (800) 888-5538 | www.functionaldevices.com 155 INTELLIGENT FIELD DEVICES INTELLIGENT FIELD DEVICE RIBMNW24B-MBAI MODbus RTU Network Relay Device, One Binary Output + Override, Two Binary Inputs, One Analog Input, 24 Vac/dc Power Input, 2.75"Track Mount Green LED=Network Status Red LED=Relay Status Pink LED=BI 1 Status Pink LED=BI 2 Status BI 1 COM BI 1 BI 2 COM BI 2 5 V 10 V 1 2 A() B(+) REF OPEN ^ To select AI for Thermistor Standard RS-485 Modbus® RTU Protocol. AI Voltage Select Switch T2 input, install jumper. EOL termination resistor jumper. 1 0 Connect jumper for terminating resistor. Relay Control 1 2 3 4 5 6 7 8 9 10 11 12 Baud Rate LSB Modbus® RTU ADDRESS MSB Both jumpers installed from factory. Remove left jumper from Thermistor-Input-Select^ for T2 Thermistor Input, otherwise leave both on for 5V or 10V Analog In. Connect Analog In between AI and AI common. Connect Thermistor between AI and Thermistor +5V. O O Not de ned O On T2 Thermistor On On Analog In 5V or 10V Type Analog AI AI COM Therm. +5V Analog In (Close only one) SW1 Closed 5 V SW2 Open 10 V SW1 Open SW2 Closed Thermistor T2 input, use 5 V selection Contacts Relay N/C } 24 Vac/dc Comm N/O C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.25 x 2.75 x 1.75 Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Gold Flash: No Relay Override Switch: DIP Switch Control Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac Network Media: Twisted Pair 22-24AWG, shielded recommended, EIA/TIA-485 (standard RS485) Terminations: Functional Devices product installed at both ends of the standard RS485 Modbus® RTU network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the Modbus® network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600 (DIP Switch Selectable) Notes: · Modbus®Address & Baud Rate must be set prior to power up via DIP switches. · This model utilizes: Physical coil 1 (Relay output) Physical binary input 1 (Dry contact binary input) Physical binary input 2 (Dry contact binary input) Physical input register AI 1 (Analog input) · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor not included. (Range -39 to 187°F) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below.^^ · Address and Baud Rate Settings on Bulletin B1676 available on website. Modbus® is a registered trademark of Schneider Electric licensed to the Modbus Organization, Inc. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 BAUD RATE 9600 19200 38400 57600 All other combinations=9600 baud DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to feed back to the network. RIBMNW24B-MBAI or RIBTW24B-MBAI Half-Wave Device 24 Vac 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). 156 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® INTELLIGENT FIELD DEVICES INTELLIGENT FIELD DEVICE RIBTW24B-MBAI MODbus RTU Network Relay Device, One Binary Output + Override, Two Binary Inputs, One Analog Input, 24 Vac/dc Power Input, NEMA 1 Housing Green LED=Network Status Red LED=Relay Status Pink LED=BI 1 Status Pink LED=BI 2 Status BI 1 COM BI 1 BI 2 COM BI 2 5 V 10 V 1 2 A() B(+) REF OPEN ^ To select AI for Thermistor Standard RS-485 Modbus® RTU Protocol. AI Voltage Select Switch T2 input, install jumper. EOL termination resistor jumper. 1 0 Connect jumper for terminating resistor. Relay Control 1 2 3 4 5 6 7 8 9 10 11 12 Baud Rate LSB Modbus® RTU ADDRESS MSB Both jumpers installed from factory. Remove left jumper from Thermistor-Input-Select^ for T2 Thermistor Input, otherwise leave both on for 5V or 10V Analog In. Connect Analog In between AI and AI common. Connect Thermistor between AI and Thermistor +5V. O O Not de ned O On T2 Thermistor On On Analog In 5V or 10V Type Analog AI AI COM Therm. +5V Analog In (Close only one) SW1 Closed 5 V SW2 Open 10 V SW1 Open SW2 Closed Thermistor T2 input, use 5 V selection Contacts Relay N/C } 24 Vac/dc Comm N/O C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin:: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac Network Media: Twisted Pair 22-24AWG, shielded recommended, EIA/TIA-485 (standard RS485) Terminations: Functional Devices product installed at both ends of the standard RS485 Modbus® RTU network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the Modbus® network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600 (DIP Switch Selectable) Notes: · Modbus®Address & Baud Rate must be set prior to power up via DIP switches. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24B-MBAI-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTW24B-MBAI-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTW24B-MBAI-N4-GY) · This model utilizes: Physical coil 1 (Relay output) Physical binary input 1 (Dry contact binary input) Physical binary input 2 (Dry contact binary input) Physical input register AI 1 (Analog input) · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor not included. (Range -39 to 187°F) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below.^^ · Address and Baud Rate Settings on Bulletin B1676 available on website. Modbus® is a registered trademark of Schneider Electric licensed to the Modbus Organization, Inc. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 BAUD RATE 9600 19200 38400 57600 All other combinations=9600 baud DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to feed back to the network. RIBMNW24B-MBAI or RIBTW24B-MBAI Half-Wave Device 24 Vac 24 Vac/dc Comm 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). (800) 888-5538 | www.functionaldevices.com 157 NOTES INTELLIGENT FIELD DEVICES 158 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER METER KIT Introducing our new BACnet® Compatible Power Meter Kit. This Power Meter Kit includes the BACnet® Compatible Power Meter circuit board, which will collect and send all the data points to the BAS controller. Also included in this Kit is the fuse holder, fuses, and disconnect switch. Everything is prepackaged and prewired in an 18-gauge steel enclosure. This Power Meter Kit is compatible with single or three-phase electrical systems. This Kit is a great solution for revenue-grade power metering applications. · Revenue Grade Power Meter · Power Meter input power: 120-277 Vac · Made in the U.S.A · Includes 16 Amp rated Disconnect Switch * · Includes Fuse holder with three 2 Amp rated fuses ^ Dimensions: 8.3" H x 7.7" W (9.2" W with switch) x 3.9" D BACnet Power Meter Kit · Power meter circuit board · Disconnect switch · Fuse holder · Fuses RIBPM413-BC-KIT POWER MONITORING A B C N A B C REF NOT USED B(+) REMOTE STATUS NOT USED LED LED A(-) * ^ # LINE 1 CT L3 LINE 2 CT L2 LINE 3 CT L1 NEUTRAL Current Transformers See page 163 for available models FOR MORE PRODUCT INFORMATION, SEE PAGE 160. (800) 888-5538 | www.functionaldevices.com 159 PPPOOOWWWEEERRRMMMEEETTTEEERRRKKIITT-- BBAACCNNEETT®® CCOOMMPPAATTIIBBLLEE RIBPM413-BC-KIT PPower Meter Kit, 120-277 Vac, 3-Phase, Disconnect Switch, Fuses and Fuse Holder C BA *** REF Not Used B(+) REMOTE STATUS Not Used A(-) LED LED CT L3 CT L2 CT L1 LINE 1 LINE 2 LINE 3 NEUT NC BA ** * SPECIFICATIONS Power Meter - RIBPM413-BC: *Power Input Rating: 120-277 Vac, Powered from Line 1 to Neutral, < 2 VA Headers: Pluggable screw terminals, accept 12 to 28 AWG wire Dimensions: 2.75" H x 4.5"W x 0.85" D with headers installed Origin: Made of US and non-US parts Frequency: 50/60 Hz Operating Temperature: -20 to 70°C, -4 to 158°F Humidity: 5 to 95% (noncondensing) Altitude: Up to 2,000 m Remote LED: Green = Rx Amber = Tx Status LED: See Bulletin B2646 Terminal Torque: 4.43 in-lbs Approvals: CE, UL Listed, UL 61010-1 and UL 61010-2-30, C-UL, RoHS, FCC Part 15 Class B Network Media: 18-22 AWG, 2-Core, shielded twisted pair Network Termination: For End of Line (EOL) device, use 120 Resistor. See Bulletin B2646 for details Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200; Set via BACnet® Fuse Holder: Type: Class CC Rated Current: 30 Amps Rated Voltage: 600 Vac Interrupt Rating: 200kA Max Ambient Temp: 125°C, 257°F Wire Gauge: 10-14 AWG Terminal Torque: 20 in-lbs Approvals: UL Listed, CSA Certified, RoHS, CE Disconnect Switch*: Rated Current: 16 Amps Rated Voltage: 600 Vac Interrupt Rating: 10kA Ambient Temperature: -25 to 50°C, -13 to 122°F Wire Gauge: 10-14 AWG Mechanical Life: 1 million cycles Terminal Torque: 7 in-lbs Approvals: UL508, IEC 60947-3, EN 60947-3 and CSA 22.2, CE, RoHS Enclosure: Construction: 18 Gauge Steel Cover Type: Screw Down Cover Dimensions: 8.3" H x 7.7"W (9.2"W with switch) x 3.9" D Rating: NEMA 1 Approvals: UL Listed, CE, RoHS Fuses**: Type: Class CC, Fast-acting Rated Current: 2 Amps Rated Voltage: 600 Vac Interrupt Rating: 200kA Approvals: CSA Certified, CE, RoHS Metered Circuit: Voltage Range: 120 - 277 Vac L-N (CAT III); 1P 2/3W, 3P 4W Voltage Overload: 1.1 x Voltage Range Voltage Burden: < 0.1 VA @ 277 Vac Frequency Range: 45 - 65 Hz Current Transformer: 333 mV Output (sold separately) Current Overload: 1.2 x CT Output Power Overload: 1.2 x Voltage Range x CT Output Measurement Accuracy: Voltage: 0.5%, < 0.2% typical from 80-120% Current: 0.5%, < 0.2% typical from 10-120% Power: 0.5%, < 0.2% typical from 10-120% Power Factor: 0.5% between 0.5 and 1.0 BACnet® Details: · Device ID Default: 277050 · MAC Address Default: 50 · Baud Rate Default: 38400 · CT-Ratings (AV-8005) must be updated with the current rating of the CTs used with the device. · See Bulletin B2646 for further details · PIC Statement available on website. https://www.functionaldevices.com/downloads/pics/BACnet-PM413_PICS.pdf Notes: · See Bulletin B2818 for installation instructions · Bi-directional for NET metering · For compatible Current Transformers, see our CT Series*** * Neutral connection required for Input Power POWER MONITORING 160 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® PPOOWWEERR MMEETTEERR - BACNET® COMPATIBLE RIBPM413-BC Power Meter, 120-277 Vac, 3-Phase, 2.75" Track Mount C BA REF Not Used B(+) REMOTE STATUS Not Used A(-) LED LED CT L3 CT L2 CT L1 LINE 1 LINE 2 LINE 3 NEUT NC BA SPECIFICATIONS *Power Input Rating: Powered from Line 1 to Neutral, 120-277 Vac, < 2 VA Headers: Pluggable screw terminal, accepts up to 12 AWG stranded copper wire Frequency: 50/60 Hz Operating Temperature: -4 to 158 °F Storage Temperature: -40 to 185 °F Humidity: 5 to 95% (noncondensing) Altitude: Up to 2,000 m Remote LED: Green = Rx Amber = Tx Status LED: See Bulletin B2646 Dimensions: 2.75" H x 4.5"W x 0.85" D with headers installed Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-4 mounting track provided Approvals: CE, UL Listed, UL 61010-1 and UL 61010-2-30, C-UL, RoHS, FCC Part 15 Class B Network Media: 18-22 AWG, 2-Core, shielded twisted pair Network Termination: For End of Line (EOL) device, use 120 Resistor. See Bulletin B2646 for details Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200; set via BACnet® Metered Circuit: Voltage Range: 120-277 Vac L-N (CAT III); 1P 2/3W, 3P 4W Voltage Overload: 1.1 x Voltage Range Voltage Burden: < 0.1 VA @ 277 Vac Frequency Range: 45 - 65 Hz Current Transformer: 333 mV Output Current Overload: 1.2 x CT Output Power Overload: 1.2 x Voltage Range x CT Output Measurement Accuracy: Voltage: 0.5%, < 0.2% typical from 80-120% Current: 0.5%, < 0.2% typical from 10-120% Power: 0.5%, < 0.2 % typical from 10-120% Power Factor: 0.5% between 0.5 and 1.0 BACnet® Details: · Device ID Default: 277050 · MAC Address Default: 50 · Baud Rate Default: 38400 · CT-Ratings (AV-8005) must be updated with the current rating of the CTs used with the device. · See Bulletin B2646 for further details · PIC Statement available on website. https://www.functionaldevices.com/downloads/pics/BACnet-PM413_PICS.pdf Notes: · See Bulletin B2646 for installation instructions · Bi-directional for NET metering * Neutral connection required for Input Power POWER MONITORING (800) 888-5538 | www.functionaldevices.com 161 PPOOWWEERR MMEETTEERR - BACNET® COMPATIBLE RIBTPM413-BC Power Meter, 120-277 Vac, 3-Phase, NEMA 1 Housing C BA REF Not Used B(+) REMOTE STATUS Not Used A(-) LED LED CT L3 CT L2 CT L1 LINE 1 LINE 2 LINE 3 NEUT NC BA SPECIFICATIONS *Power Input Rating: Powered from Line 1 to Neutral, 120-277 Vac, < 2 VA Headers: Pluggable screw terminal, accepts up to 12 AWG stranded copper wire Frequency: 50/60 Hz Operating Temperature: -4 to 158 °F Storage Temperature: -40 to 185 °F Humidity: 5 to 95% (noncondensing) Altitude: Up to 2,000 m Remote LED: Green = Rx Amber = Tx Status LED: See Bulletin B2646 Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin:: Made of US and non-US parts Track Mount: MT212-6 mounting track provided Approvals: CE, UL Listed, UL 61010-1 and UL 61010-2-30, C-UL, RoHS, FCC Part 15 Class B (circuit board) Housing Ratings: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Network Media: 18-22 AWG, 2-Core, shielded twisted pair For End of Line (EOL) device, use Network Termination: 120 Resistor. See Bulletin B2646 for details Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200; set via BACnet® Metered Circuit: Voltage Range: 120-277 Vac L-N (CAT III); 1P 2/3W, 3P 4W Voltage Overload: 1.1 x Voltage Range Voltage Burden: < 0.1 VA @ 277 Vac Frequency Range: 45 - 65 Hz Current Transformer: 333 mV Output Current Overload: 1.2 x CT Output Power Overload: 1.2 x Voltage Range x CT Output Measurement Accuracy: Voltage: 0.5%, < 0.2% typical from 80-120% Current: 0.5%, < 0.2% typical from 10-120% Power: 0.5%, < 0.2 % typical from 10-120% Power Factor: 0.5% between 0.5 and 1.0 BACnet® Details: · Device ID Default: 277050 · MAC Address Default: 50 · Baud Rate Default: 38400 · CT-Ratings (AV-8005) must be updated with the current rating of the CTs used with the device. · See Bulletin B2646 for further details · PIC Statement available on website. https://www.functionaldevices.com/downloads/pics/BACnet-PM413_PICS.pdf Notes: · See Bulletin B2646 for installation instructions · Bi-directional for NET metering · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTPM413-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTPM413-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTPM413-BC-N4-GY) * Neutral connection required for Input Power POWER MONITORING 162 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RIB CURRENT TRANSFORMERS PPOOWWEERRMMEETTEERR KIT- BA®CNET® COMPATIBLE POWER MONITORING CT-05A0-333 CT-100A2-333 CT-400A4-333 ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV CT-100A1-333 CT-100A4-333 CT-200A4-333 CT-025A1-333 CT-050A1-333 CTS-100A55-333 MOD1-07-33MV FDI MODEL CT-05A0-333 CT-025A1-333 CT-050A1-333 CT-100A1-333 CT-100A2-333 CT-100A4-333 CT-200A4-333 CT-400A4-333 CT-600A4-333 CTS-05A20-333 CTS-30A20-333 CTS-60A35-333 CTS-100A55-333 ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV PRIMARY INPUT (A) SECONDARY OUTPUT (V) RATIO 5 25 50 100 100 100 200 400 600 5 30 60 100 4,000 6,000 8,000 10,000 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.07 0.07 0.07 0.07 5A/0.333V 25A/0.333V 50A/0.333V 100A/0.333V 100A/0.333V 100A/0.333V 200A/0.333V 400A/0.333V 600A/0.333V 5A/0.333V 30A/0.333V 60A/0.333V 100A/0.333V 4,000/70mV 6,000/70mV 8,000/70mV 10,000/70mV ACCURACY (%) 0.3 0.8 0.5 0.5 0.75 0.5 0.5 0.5 0.5 0.2 0.2 0.2 0.2 0.75 0.75 0.75 0.75 CORE TYPE Split Split Split Split Split Split Split Split Split Solid Solid Solid Solid Rope Rope Rope Rope WINDOW SIZE .47" x .45" .72" x .62" .72" x .62" .72" x .62" 1.0" x 1.4" 1.3" x 1.7" 1.3" x 1.7" 1.3" x 1.7" 1.3" x 1.7" .2" diameter .2" diameter .35 diameter .55 diameter 5.0" diameter 7.6" diameter 11.5" diameter 15.3" diameter "MOD" & "ROPE" Series The MOD series of devices are optional modules that connect to the output of the Rogowski Coil CTs (ROPE units) and convert the output to the 0.333 V analog scale for use in other Power Monitoring systems. The MOD series has options for one, two, or three-phase power feeds. The MOD series devices are DIN rail-mountable, are ETL approved, and require 12 Vdc for input voltage. FDI MODEL MOD1-07-33MV MOD2-07-33MV MOD3-07-33MV ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV PRIINPUT (A) 0.07 0.07 0.07 4,000 6,000 8,000 10,000 SECONDARY OUTPUT (V) 0.333 0.333 0.333 0.07 0.07 0.07 0.07 ACCURACY (%) 0.50 0.50 0.50 0.75 0.75 0.75 0.75 USED WITH Any "ROPE" CT Any "ROPE" CT Any "ROPE" CT Any "MOD" CT Any "MOD" CT Any "MOD" CT Any "MOD" CT (800) 888-5538 | www.functionaldevices.com 163 POWER CONTROL PSH600-UPS-STAT POWER CONTROL PSPT2RB4 PSM2RB10 PSMS1 PSMN24SB10 POWER CONTROL SIB05S-RD Enclosed Power Control Centers · Two 120 Vac grounded convenience outlets · 4 or 10 Amp switch / circuit breaker · Outlets can be continuously powered or controlled by the switch / circuit breaker. · True override switch on load side of relay · Auxiliary outputs are provided for convenient control panel installations. Track Mount Circuit Breaker Switches · Track mount circuit breaker switches provide a convenient addition to control panels. · Circuits can be low voltage (24 Vac) or line voltage (120 Vac). Prepackaged Switches · Standard configurations to provide simple switching schemes. · Labels can be ordered with custom content to fit your project. UPS Power Supplies · Perfect for applications in hospitals, laboratories and research & surgery centers · Keep your critical controller powered on during a loss of normal utility power with the ability to hardwire line voltage to the provided UPS, in addition to hardwiring the UPS to the final load. · Kits include: 600 or 850 VA commercial UPS, NEMA 1 metal enclosure, and interface board · BACnet® compatible model is BTL Certified and includes six objects: Line or UPS power, UPS percent load, VA load, UPS battery capacity, USB connection, and remaining battery time. · Cords tuck inside enclosure for clean & neat use of a UPS. · 120 Vac convenience outlet(s) provided · 10 Amp circuit breaker / switch can be used to test functionality of UPS. · Switch controls line voltage 164 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® POWER CONTROL ENCLOSED POWER CONTROL CENTERS MODEL # PSPT2RB4 120 VAC OUTLETS · 2 SWITCH On / Off CIRCUIT BREAKER 4 Amp PSPW2RB4 · 2 On / Off 4 Amp PSPT2RB10 · 2 On / Off 10 Amp PSPW2RB10 · 2 On / Off 10 Amp HEIGHT 4.000 4.000 4.000 4.000 WIDTH 4.000 4.000 4.000 4.000 DEPTH 1.800 1.800 1.800 1.800 WIRES · · TERMINALS · · SPEC PAGE 166 166 166 166 TRACK MOUNT CIRCUIT BREAKER SWITCHES. MODEL # PSMN01SB4 PSMN01SB10 PSMN24SB4 PSMN24SB10 POWER INPUT SWITCH LED · 120 Vac On / Off · · 120 Vac On / Off · · 24 Vac On / Off · · 24 Vac On / Off · CIRCUIT BREAKER 4 Amp 10 Amp 4 Amp 10 Amp HEIGHT 1.350 1.350 1.350 1.350 WIDTH 2.750 2.750 2.750 2.750 DEPTH 1 DEPTH 2 2.000 2.500 2.000 2.500 2.000 2.500 2.000 2.500 TRACK MOUNT MT212-2 included MT212-2 included MT212-2 included MT212-2 included SPEC PAGE 166 166 166 166 PREPACKAGED SWITCHES MODEL # PSMS1 RELAY CONTACTS · 1 SPST SWITCH Maintained 3 Position SIB02S · 1 SPDT Maintained 3 Position SIB04S · 1 SPDT Maintained 2 Position (On / On) SIB05S · 1 SPST Maintained 2 Position (On / Off) SIBLS · 1 SPDT Maintained 3 Position SWITCH RATING 5 Amp @ 30 Vac/dc 20 Amp @ 277 Vac 20 Amp @ 277 Vac 20 Amp @ 277 Vac 5 Amp @ 30 Vac/dc HEIGHT 1.280 1.700 1.700 1.700 1.700 WIDTH 4.000 2.800 2.800 2.800 2.800 DEPTH 1 1.250 1.500 1.500 1.500 1.500 DEPTH 2 ENCLOSED 1.750 · · · · TRACK MOUNT MT4 Series sold separately SPEC PAGE 167 167 167 168 168 UPS POWER SUPPLIES. MODEL # PSH600-UPS (Kit)# CIRCUIT 120 VAC TRACK SPEC STATUS UPS BREAKER OUTLET(S) COMPATIBLE KIT ENCLOSED MOUNT HEIGHT WIDTH DEPTH 1 DEPTH 2 PAGE 600 VA · · N/A · 12.000 14.000 6.000 169 PSH2RB10 · · · PSH600-UPS · 12.000 14.000 6.000 169 PSM2RB10 · · · PSH600-UPS MT4-4N included 3.250" 4.100" 1.250 1.750 170 PSMN2RB10 · · · MT212-6N included 4.750" 2.750" 1.250 1.750 170 PSH600-UPS-STAT (Kit)# · 600 VA · · N/A · 12.000 16.000 6.000 171 PSH2C2RB10 ·· · · PSH600-UPS-STAT · 12.000 16.000 6.000 172 PSMN2C2RB10 ·· · · PSH600-UPS-STAT MT212-6N included 6.660 2.750" 1.250 1.750 172 PSH850-UPS-STAT (Kit)* · 850 VA · · N/A · 14.000 16.000 6.000 173 PSH2C2RB10-L ·· · · PSH850-UPS-STAT · 14.000 16.000 6.000 173 PSH600-UPS-BC (Kit)# · 600 VA · · · N/A · 12.000 16.000 6.000 174 For full product information on "UPS" models, see our website. = UL Listed - see data sheet for specific Listing # = For replacement UPS order UPS600 * = For replacement UPS order UPS850 POWER CONTROL (800) 888-5538 | www.functionaldevices.com 165 SWITCH / CIRCUIT BREAKER COMBOS PSPT2RB4 Power Control Center, 4 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Terminals, NEMA 1 Housing PSPT2RB10 Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Terminals, NEMA 1 Housing Outlets will always be energized when jumper is in this position. INPUT Outlets will be controlled by switch/breaker when jumper is in this position. OUTPUT Outlets will always be energized when jumper is in this position. INPUT Outlets will be controlled by switch/breaker when jumper is in this position. OUTPUT ALWAYS HOT SWITCHED ALWAYS HOT SWITCHED G N H H N G G N H H N G GND "G" and Neutral "N" pass from INPUT to OUTPUT uninterrupted. Output Hot "H" is controlled by switch/breaker. GND "G" and Neutral "N" pass from INPUT to OUTPUT uninterrupted. Output Hot "H" is controlled by switch/breaker. PSPW2RB4 Power Control Center, 4 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Wires, NEMA 1 Housing PSPW2RB10 Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Wires, NEMA 1 Housing Green Wire White Wire Black Wire ALWAYS HOT Outlets will always be energized when jumper is in this position. INPUT G N H SWITCHED Blue Wire Outlets will be controlled by switch/breaker when jumper is in this position. OUTPUT H N G Outlets will always be energized when jumper is in this position. INPUT G N H BLUE = LOAD Blue wire is controlled by switch/breaker. Green Wire White Wire Black Wire ALWAYS HOT SWITCHED Blue Wire Outlets will be controlled by switch/breaker when jumper is in this position. OUTPUT H N G BLUE = LOAD Blue wire is controlled by switch/breaker. AT4 SERIES SELECTION GUIDE Model # PSPT2RB4 PSPT2RB10 PSPW2RB4 PSPW2RB10 Circuit Breaker 4 Amps 10 Amps 4 Amps 10 Amps Terminals · · Wires · · SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Circuit Breaker: 4 Amp Max. or 10 Amp Max. Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated (PSPW2RB4 & PSPW2RB10) Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Terminals: Ground "G and Neutral "N pass from INPUT to OUTPUT uninterrupted. OUTPUT Hot blue wire is controlled by the switch/breaker. TRACK MOUNT CIRCUIT BREAKER SWITCHES Notes: · Indicator light will illuminate when switch/breaker is ON (RESET position) indicating power has been transferred from INPUT to OUTPUT by the switch/breaker. If it is desired for the indicator light to be illuminated continuously to indicate the presence of input (Line) power, INPUT and OUTPUT may be reversed -- connect input power from line to OUTPUT and connect output load to INPUT (operation of the jumpers above also reverses). PSMN01S SERIES Switch, 2 Position Maintained, On/Off, 4 Amp or 10 Amp Circuit Breaker, 120 Vac, 2.75" Track Mount Temperature Compensation 1.40 PSMN24S SERIES Switch, 2 Position Maintained, On/Off, 4 Amp or 10 Amp Circuit Breaker, 24 Vac, 2.75" Track Mount Temperature Compensation 1.40 1.30 1.30 1.20 1.20 1.10 1.10 1.00 1.00 0.90 0.90 0.80 0.80 0.70 0.70 0.60 -20 -10 0 10 20 30 40 50 60 Ambient Temperature in Degrees Centigrade (ºC) 0.60 -20 -10 0 10 20 30 40 50 60 Ambient Temperature in Degrees Centigrade (ºC) PSMN01S SERIES Model # Circuit Breaker PSMN01SB4 4 Amps PSMN01SB10 10 Amps SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Circuit Breaker: 4 Amp or 10 Amp Dimensions: 1.35"H x 2.75"W x 2.00"D1/2.50"D2 PSMN24S SERIES Model # Circuit Breaker PSMN24SB4 4 Amps PSMN24SB10 10 Amps Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-2 Mounting Track Provided OVER CURRENT / SHORT CIRCUIT PROTECTION AND SWITCHING Approvals: UL Listed, UL916, C-UL, CE, RoHS Blk 120 Vac Wht ON OFF Load POWER CONTROL Correction Factor Correction Factor 166 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® PREPACKAGED SWITCH PSMS1 Switch, 3 Position Maintained, 5 Amp, 30 Vac/dc, 4.00" Track Mount Power Input Vac/dc (+ if DC) Controller DO Comm (- if DC) CLOSED Green OPEN OUT AUTO Red Yellow Comm (- if DC) SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.28"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately PREPACKAGED SWITCH SIB02S Switch, 20 Amp, 3 Position Maintained, Center Off, 3 Wires, NEMA 1 Housing Blu Switch Status: Green LED On = Power Input present Yellow LED On = Controller DO ON Red LED On = Output Signal ON Approvals: UL Listed, UL916, C-UL, CE, RoHS Switch Ratings: 5 Amp @ 30 Vac/dc CLOSED OPEN Yel AUTO Org SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Switch Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 10 Amp Tungsten @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac PREPACKAGED SWITCH SIB04S Switch, 20 Amp, 2 Position Maintained, On/On, 3 Wires, NEMA 1 Housing Blu SIB02S-RD · Red housing Notes: · Switch position label can be custom printed according to your needs, simply consult factory CLOSED Yel AUTO Org SIB04S-RD · Red housing SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Switch Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 10 Amp Tungsten @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Notes: · Switch position label can be custom printed according to your needs, simply consult factory (800) 888-5538 | www.functionaldevices.com 167 POWER CONTROL PREPACKAGED SWITCH SIB05S Switch, 20 Amp, 2 Position Maintained, On/Off, 2 Wires, NEMA 1 Housing Org ON Org OFF SIB05S-RD · Red housing SPECIFICATIONS Operating Temperature: -30 to 140° F Switch Ratings: Humidity Range: 5 to 95% (noncondensing) 20 Amp Resistive @ 277 Vac Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple 1110 VA Pilot Duty @ 277 Vac Housing Detail: See Housing A in housing guide for dimensions 770 VA Pilot Duty @ 120 Vac Origin: Made of US and non-US parts 20 Amp Ballast @ 277 Vac Wires: 16, 600V Rated 10 Amp Tungsten @ 120 Vac Approvals: UL Listed, UL916, C-UL, CE, RoHS 2 HP @ 277 Vac Housing Rating: UL Accepted for Use in Plenum, NEMA 1 1 HP @ 120 Vac PREPACKAGED SWITCH SIBLS Switch, 5 Amp, 30 Vac/dc, 3 Position Maintained, On/Off/On, LED Indicator, NEMA 1 Housing Wht/Blu ( + if d/c) Notes: · Switch position label can be custom printed according to your needs, simply consult factory CLOSED OPEN AUTO Brn ( + if d/c) Org Wht/Yel ( if d/c) * SIBLS-RD · Red housing SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Switch Rating: 5 Amp @ 30Vac/dc Notes: · Switch position label can be custom printed according to your needs, simply consult factory · Connection to Wht/Yel may be omitted if LED is not needed * POWER CONTROL 168 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® UNINTERUPTABLE POWER SUPPLY KIT PSH600-UPS 600VA UPS Backup Power Control Center, 12" x 14" x 6" Metal Enclosure UPS (Not Included) 120 Vac On/O Switch, Breaker Line Input & Indicator Light } UPS Output GND Neut. Hot GND Line Input Hot RESET OFF Neut. Shown Without Cover GND Neut. Hot From UPS } To UPS To Protected Device Computer Outlet To UPS SPECIFICATIONS UPS UPS: 600VA Backup Time: 2.5 Min. @ Full 600 VA Load 10 Min. @ 1/2 Load Power Consumption Up to 3 Amp @120 Vac Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778 PSH2RB10 Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS Dimensions: 12.000 H x 14.000 W x 6.000 D Metal Housing with Screw Cover Origin: Made of US and non-US parts Notes: · To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2RB10. · To order interface board for replacement or for separate use, order model PSMN2RB10. · Average battery life: 3-5 years depending on the number of discharge cycles and environmental temperature · UPS may change based on quality and availability UNINTERUPTABLE POWER SUPPLY KIT PSH2RB10 UPS Power Control Center, 2.75" Track Mount in 12" x 14" x 6" Metal Enclosure UPS (Not Included) 120 Vac On/O Switch, Breaker Line Input & Indicator Light } UPS Output GND Neut. Hot GND Line Input Hot RESET OFF Backup Time (Minutes) ESTIMATED BACKUP TIME VS. LOAD Load (Watts) Shown With Cover Neut. GND Neut. Hot From UPS } To UPS To Protected Device Computer Outlet To UPS Shown Without Cover SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS Dimensions: 12.000 H x 14.000 W x 6.000 D Metal Housing with Screw Cover Origin: Made of US and non-US parts Notes: · Track mounted interface board may be ordered separately as model PSMN2RB10, to be used with any commercial UPS with appropriate ratings for the circuit breaker. · Circuit breaker for short protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · Max. size: 12.000 x 7.250 x 5.500 · 120 Vac max., 600 W max., 8.3 Amp max. · UPS is not included. POWER CONTROL (800) 888-5538 | www.functionaldevices.com 169 UPS INTERFACE MODULE PSM2RB10 UPS Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Terminals, 4.00" Track Mount UPS (Not Included) } To Protected 120 Vac On/O Switch, Breaker Device Line Input & Indicator Light } UPS Output Line Input RESET Hot OFF Neut. GND GND Neut. Hot To UPS Computer Outlet BUY SEPARATELY AND PLACE IN AN ENCLOSURE OF YOUR CHOICE From UPS To UPS SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 3.25"H x 4.10"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 3.250 x 4.000 MT4-4N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS Origin: Made of US and non-US parts UPS INTERFACE MODULE Notes: · Circuit breaker for short protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · UPS is not included. PSMN2RB10 UPS Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Terminals, 2.75" Track Mount 120 Vac On/O Switch, Breaker Line Input & Indicator Light } UPS (Not Included) UPS Output Line Input RESET GND UPS INTERFACE MONeDutU. LE Hot GND Hot OFF Neut. GND Neut. Hot From UPS } To UPS To Protected Device Computer Outlet To UPS BUY SEPARATELY AND PLACE IN AN ENCLOSURE OF YOUR CHOICE SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 4.75"H x 2.75"W x 1.25"D1/1.75"D2 Housng Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 x 6.000 MT212-6N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS Notes: · Circuit breaker for short protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · UPS is not included. POWER CONTROL 170 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® UNINTERUPTABLE POWER SUPPLY KIT PSH600-UPS-STAT 600VA UPS Backup Power Control Center, Status Contacts, 12" x 14" x 6" Metal Enclosure UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator } GND } Neut. Line N/C } COM N/O N/C COM N/O UPS GND Neut. Line RESET OFF Shown Without Cover Line Neut. GND From UPS Backed Up Outlet } } To Protected Device To UPS UPS plugged into one of two outlets. Other outlet is spare. SPECIFICATIONS UPS UPS: 550 or 600VA Backup Time: 2.5 Min. @ Full 600 VA Load 10 Min. @ 1/2 Load Power Consumption Up to 3 Amp @120 Vac Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778 Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc (N/O) 7 Amp @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 1000 VA @ 120 Vac Magnetic Ballast (N/C) C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty PSH2C2RB10 Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS Dimensions: 12.000 H x 14.000 W x 6.000 D Metal Housing with Screw Cover Origin: Made of US and non-US parts Notes: · To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2C2RB10. · To order interface board for replacement or for separate use, order model PSMN2C2RB10. · Average battery life: 3-5 years depending on the number of discharge cycles and environmental temperature · UPS may change based on quality and availability Backup Time (Minutes) ESTIMATED BACKUP TIME VS. LOAD Load (Watts) UPS Status Contacts and LED Indicator The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on. Input Power Status Contacts and LED Indicator The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is de-energized, and the LED is off. POWER CONTROL (800) 888-5538 | www.functionaldevices.com 171 ENCLOSED UPS INTERFACE MODULE PSH2C2RB10 UPS Power Control Center Interface Board, Status Contacts, 2.75" Track Mount in 12" x 16" x 6" Metal Enclosure UPS (Not Included) UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator GND } Neut. Line N/C } COM N/O N/C COM N/O GND Neut. Line RESET OFF } Shown With Cover Line Neut. GND } From UPS Backed-Up Outlet To Protected Device To UPS UPS plugged into one of two outlets. Other outlet spare. } Shown Without Cover SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS, NEMA 1 Dimensions: 4.75"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Metal Housing with Screw Cover Origin: Made of US and non-US parts UPS Status Contacts and LED Indicator The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on. Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc N/O 7 Amp @ 30 Vdc N/C 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 100 VA @ 120 Vac Ballast N/C C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty Notes: · Track mounted interface board may be ordered separately as model PSMN2C2RB10, to be used with any commercial UPS with appropriate ratings for the circuit breaker. · Circuit breaker for short-circuit protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · Max. size: 12.000 x 7.250 x 5.500 · 120 Vac max., 600 W max., 8.3 Amp max. · UPS is not included. Input Power Status Contacts and LED Indicator The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is de-energized, and the LED is off. UPS INTERFACE MODULE PSMN2C2RB10 UPS Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Terminals, Status Contacts, 2.75" Track Mount } UPS (Not Included) UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator GND } Neut. Line N/C } COM N/O N/C COM N/O GND Neut. Line RESET OFF POWER CONTROL Line Neut. GND } } From UPS Backed-Up Outlet To Protected Device To UPS UPS plugged into one of two outlets. Other outlet spare. BUY SEPARATELY AND PLACE IN AN ENCLOSURE OF YOUR CHOICE SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 6.66"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 2.750 x 6.000 MT212-6N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS Origin: Made of US and non-US parts Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc N/O 7 Amp @ 30 Vdc N/C 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 100 VA @ 120 Vac Ballast N/C C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty Notes: · Circuit breaker for short-circuit protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · UPS is not included. UPS Status Contacts and LED Indicator The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on. Input Power Status Contacts and LED Indicator The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is de-energized, and the LED is off. 172 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® UNINTERUPTABLE POWER SUPPLY KIT PSH850-UPS-STAT 850VA UPS Backup Power Control Center, Status Contacts, 14" x 16" x 6" Metal Enclosure UPS UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator GND } Neut. Line N/C } COM N/O N/C COM N/O GND Neut. Line RESET OFF } Shown Without Cover Shown With Cover Line Neut. GND From UPS Backed Up Outlet } To Protected Device To UPS UPS plugged into one of two outlets. Other outlet spare. } SINUSOIDAL OUTPUT OR PURE SINE WAVE OUTPUT SPECIFICATIONS UPS UPS: 850VA Backup Time: 2 Min. @ Full 850 VA Load 8 Min. @ 1/2 Load Input: 120 Vac, 12 Amp Sine Wave Output: 120 Vac, 7.1 Amp Max Load: 510 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 95° F UPS Transfer Time: 4ms Approvals: UL Listed, UL1778 Model: Cyber Power Model 850PFCLCD PSH2C2RB10-L Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS Dimensions: 14.000 H x 16.000 W x 6.000D Metal Housing with Screw Cover Origin: Made of US and non-US parts Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc (N/O) 7 Amp @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 1000 VA @ 120 Vac Magnetic Ballast (N/C) C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty Backup Time (Minutes) ESTIMATED BACKUP TIME VS. LOAD 70 60 50 40 30 20 10 Notes: · To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2C2RB10-L. · To order interface board for replacement or for separate use, order model PSMN2C2RB10. · Typical battery life: 3-6 years, depending on number of discharge/recharge cycles 0 0 100 200 300 400 500 550 Load (Watts) UPS Status Contacts and LED Indicator The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on. Input Power Status Contacts and LED Indicator The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is deenergized, and the LED is off. ENCLOSED UPS INTERFACE MODULE PSH2C2RB10-L UPS Power Control Center Interface Board, Status Contacts, 2.75"Track Mount in 14" x 16" x 6" Metal Enclosure UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator } GND } Neut. Line N/C } COM N/O UPS (Not Included) GND Neut. Line RESET OFF N/C COM N/O Shown Without Cover Shown With Cover Line Neut. GND From UPS Backed Up Outlet } To Protected Device To UPS SPECIFICATIONS } UPS plugged into one of two outlets. Other outlet spare. Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS Dimensions: 14.000H x 16.000W x 6.000D Metal Housing with Screw Cover Origin: Made of US and non-US parts Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc N/O 7 Amp @ 30 Vdc N/C 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 1000 VA @ 120 Vac Magnetic Ballast N/C C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty Notes: · Track mounted interface board may be ordered separately as model PSMN2C2RB10, to be used with any commercial UPS with appropriate ratings for the circuit breaker. · Circuit breaker for short-circuit protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · Max. size: 14.000 x 10.000 x 5.500 · 120 Vac, 600 W max., 8.3 Amp max. · UPS is not included. · To order a kit with a UPS, see PSH850-UPS-STAT. UPS Status Contacts and LED Indicator The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on. Input Power Status Contacts and LED Indicator The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is de-energized, and the LED is off. (800) 888-5538 | www.functionaldevices.com 173 POWER CONTROL UNINTERUPTABLE POWER SUPPLY KIT - BACNET COMPATIBLE PSH600-UPS-BC 600 VA UPS Backup Power Control Center, BACnet MS/TP Network, 12" x 14" x 6" Metal Enclosure UPS Line Neut. Gnd. Gnd. Neut. Line Red LED = Device Power Pink LED = Device Status Green LED = Network Comm. } UPS Output to protected device Line Input RESET OFF 1 2 3 4 5 6 7 8 9 10 OPEN UPS plugged into one of two outlets. Other outlet spare. EOL Jumper Yellow LED = Backup Power Blue LED = USB Status B(+) A(-) BACnet® REF comm. USB Jack To UPS Shown Without Cover SPECIFICATIONS BOARD AND ENCLOSURE: Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Indicators: Device Power: Red LED Device Status: Pink LED Network Communication: Green LED Backup Power: Yellow LED USB Status: Blue LED Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 12" H x 14 W x 6 D Origin: Made of US and non-US parts Track Mount: 2.750 x 8.000 MT212-8N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS Line Input: 120Vac, 10A(max) Convenience Receptacles: 120Vac, 10A(max combined) UPS: UPS: 600VA Backup Time: 2.5 Min. @ Full 600 VA Load 10.2 Min. @ 1/2 Load Input: 120 Vac, 12 Amp Output: 120 Vac, 4.6 Amp Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778 Power Input Rating: Notes: 25mA @ 120Vac · Circuit breaker for short-circuit protection. Network Media: · 14/3 Line Cord included (3´). Twisted Pair 22-24 AWG, shielded recommended (MS/TP) USB A/B (device to UPS, included) BACnet® Details: Terminations: · MS/TP Address & Baud Rate must be set prior Functional Devices product installed at both ends of the to power up via DIP switches. MS/TP network - Use 120 Ohm End of Line Resistors. All · Device ID will default to 277XXX where XXX is other cases follow instructions from the device installed the MS/TP Address. at the end of the MS/TP network. Examples: Polarity: Network is polarity sensitive. Baud Rate: 9600, 192000, 38400, 76800, 115200 ( DIP Switch Selectable) MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Devices Instance changed via Object Identifier Property of Device Object. · Status of UPS connection, Battery run time, line power ,UPS load (VA and %), and battery capacity can be read from BACnet network. All other combinations=9600 baud ESTIMATED BACKUP TIME VS. LOAD 60 Notes: · Average battery life: 3-5 years depending on the number of discharge 50 cycles and environmental temperature · This model is not designed to notify user of battery failure. · This model is designed to work exclusively with Functional Devices Model UPS600 40 INFORMATION PROVIDED OVER BACNET® NETWORK CAN BE USED TO SCHEDULE "PREDICTIVE MAINTENANCE" SUCH AS UPS BATTERY REPLACEMENT, ETC. 30 20 10 0 0 50 100 150 200 250 300 350 Load (Watts) POWER CONTROL Backup Time (Minutes) 174 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® HVAC & LIGHTING ENERGY MANAGEMENT Gateway/BMS Key Card Switch controls access to a room and turns on heating and lighting when entering a room Position Sensors set back HVAC when windows are open Occupancy Sensor adjusts temperature and turns off lights when a room is not in use Batteryless Wireless Switches control lighting WIRELESS DEVICES YOUR PAYBACK/ROI · 70% COST SAVINGS IN RETROFITS · 40% ENERGY SAVINGS · UNLIMITED FLEXIBILITY 902 MHz · Maintenance-free Flexibility of applications · Time saving Cost savings in installation, renovation, and energy usage Many hotels keep their rooms at a comfortable temperature for the duration of their guests' stays whether the guests are in or out of their room. With guest comfort as a priority, hotels and motels typically use almost 40 percent of their electricity on heating and cooling rooms, even though studies show that most sold rooms are unoccupied for 12 or more hours a day. Used correctly, the right controls could offer significant energy savings without compromising the comfort of guests. Information from: EnOcean® Alliance & ENERGY STAR Building Upgrade Manual (800) 888-5538 | www.functionaldevices.com 175 ENOCEAN® ENABLED WIRELESS DEVICES RIBW01B-EN3 RIBW01C-EN3 WDWS2-EN3 WWS2-EN3 WKC-EN3 WVSCM-EN3 WVSWM-EN3 EnOcean® Enabled Wireless RIB® Relay Receivers & Transceivers work in conjunction with many 902 MHz EnOcean® enabled transmitters. Wireless wall switches, occupancy sensors, thermostats, key card switches, and patio & door switches are all devices which can activate the RIB® Wireless Control Relays by using EnOcean's "energy harvesting" technology. Energy harvesting refers to the process by which energy is captured and stored, then used to transmit a wireless signal, which in turn is received by the RIB® Wireless Relay. WIRELESS CONTROL RELAYS COIL VOLTAGE CONTACT RATINGS MODEL # RELAY AC/DC AC CONTACTS RESISTIVE MOTOR REPEAT DRY CONTACT DIMMER HOUSING SPEC PILOT DUTY FUNCTION INPUT FUNCTION STYLE * FREQUENCY PAGE RIBW01B-EN3 · 120 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · · B 902 MHz 177 RIBW208B-EN3 · 208 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · · B 902 MHz 177 RIBW240B-EN3 · 240 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · · B 902 MHz 177 RIBW277B-EN3 · 277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · · B 902 MHz 177 RIBW24B-EN3 · 24 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · · B 902 MHz 177 RIBW21BAO-EN3 · 120-277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac · · B 902 MHz 178 RIBW01C-EN3 · 120 1 SPST 5 A Ballast @ 120/277 Vac; 5 A Elec. Ballast @ 120 Vac · Ballast size 902 MHz 178 RIBW02C-EN3 · 208-277 1 SPST 5 A Ballast @ 120/277 Vac; 5 A Elec. Ballast @ 120 Vac · Ballast size 902 MHz 178 WIRELESS PHASE ANGLE DIMMER POWER INPUT MODEL # RIBW01F600-EN3 · AC/DC AC 120 Vac REPEAT DRY CONTACT DIMMER HOUSING SPEC FUNCTION INPUT FUNCTION STYLE * FREQUENCY PAGE · · C 902 MHz 179 WIRELESS TRANSMITTERS MODEL # WWS2-EN3 DESCRIPTION Wall switch with barrier & cover plate POWER INPUT Self-Powered ENOCEAN® ENERGY HARVESTING · FREQUENCY 902 MHz COLOR White SPEC PAGE 180 WDWS2-EN3 Door and window switch Light-Powered · 902 MHz White 180 WKC-EN3 Keycard switch Self-Powered · 902 MHz White 180 WVSCM-EN3 Occupancy / vacancy sensor, ceiling mount Light-Powered · 902 MHz White 181 WVSWM-EN3 Occupancy / vacancy sensor, wall mount Light-Powered · 902 MHz White 181 WVSUS-EN3 Occupancy / vacancy sensor, ceiling mount Light-Powered · 902 MHz White 182 WIRELESS ACCESSORIES MODEL # AWSTFM WSTP-W DESCRIPTION Flush Surface Mount Backplate Kit for WWS2-EN3 Wall Switch Plate Replacement SPEC PAGE 182 182 = UL Listed - see data sheet for specific Listing * = See Housing Guide on page 201 176 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® WIRELESS DEVICES WIRELESS CONTROL RELAYS WITH TWO-WAY COMMUNICATION RIBW01B-EN3 EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT, 120 Vac Power Input, Dry Contact Input, NEMA 1 Housing RIBW208B-EN3 EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT, 208 Vac Power Input, Dry Contact Input, NEMA 1 Housing RIBW240B-EN3 EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT, 240 Vac Power Input, Dry Contact Input, NEMA 1 Housing Blu N/C Blk 120 Vac (RIBW01B-EN3) Yel 208 Vac (RIBW208B-EN3) C 240 Vac (RIBW240B-EN3) 277 Vac (RIBW277B-EN3) Wireless Org Receiver N/O Wht Neutral or Other Phase Control Circuit Wht/Red Wht/Blu RIBW01B-EN3 RIBW208B-EN3 RIBW240B-EN3 RIBW277B-EN3 Blu N/C RIBW277B-EN3 EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT, 277 Vac Power Input, Dry Contact Input, NEMA 1 Housing Yel Wht/Yel C 24 Vac/dc Wht/Yel 24 Vac/dc Wireless Org Transceiver N/O Control Circuit RIBW24B-EN3 EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT, 24 Vac/dc Power Input, Dry Contact Input, NEMA 1 Housing Wht/Red Wht/Blu RIBW24B-EN3 Learn Clear RELAY HAS BUILT-IN REPEATER FUNCTION. RELAY RECEIVES SIGNAL FROM WIRELESS SWITCH TRANSMITTER AND REBROADCASTS THE SIGNAL TO THE NEXT RELAY RECEIVER. SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Red LED: Relay Status / Learn Mode Status (Flashing) Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple Housing Details: See Housing B in housing guide for demensions Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, RoHS Agency Compliance: FCCID: SZV-TCM320U IC: 5713A-TCM320U Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Frequency: 902 MHz Receiver Sensitivity: -93 dBm typical Conducted Power: 5 mW typical Built-in Switch Modes: Alarm, Repeater, Delay, Rocker, Momentary, and Toggle Origin: Made of US and non-US parts Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 73 mA @ 120 Vac ; 60 Hz (RIBW01B-EN3) 80 mA @ 208 Vac ; 60 Hz (RIBW208B-EN3) 80 mA @ 240 Vac ; 60 Hz (RIBW240B-EN3) 80 mA @ 277 Vac ; 60 Hz (RIBW277B-EN3) 69 mA @ 24 Vdc (RIBW24B-EN3) 139 mA @ 24 Vac (RIBW24B-EN3) Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft. · Open area transmission could be farther. Consult factory for more information. · Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used. · Version 1.5 firmware or later implements Functional Devices, Inc.'s EnOcean® Manufacturer ID of 0x055. · For setup instructions, see website for -EN3 Series Application Manual: www.functionaldevices.com/wp-content/uploads/2021/12/ B1867_393231.pdf APPLICATION FOR WIRELESS CONTROL & FEEDBACK IN A BUILDING AUTOMATION SYSTEM BAS Panel Wht/Red and Wht/Blu DO Org Wht/Yel Wht 60Hz A/C Power DI Yel Load Current Sensor Wht/Red Wht/Blu Dry contact input for load veri cation BAS Controller Org Yel WIRELESS DEVICES (800) 888-5538 | www.functionaldevices.com 177 WIRELESS CONTROL RELAY RIBW21BAO-EN3 EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT, 120-277 Vac Power Input, 0-10 Vdc Analog Output, NEMA 1 Housing Blu N/C Yel C Blk 120-277 Vac Wireless Org Transceiver N/O Red Neutral or Control Other Phase Circuit Prp 0-10Vdc Gry Com RELAY HAS BUILT-IN REPEATER FUNCTION. RELAY RECEIVES SIGNAL FROM WIRELESS SWITCH TRANSMITTER AND REBROADCASTS THE SIGNAL TO THE NEXT RELAY RECEIVER. Learn Clear SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Contact Ratings: Expected Relay Life: 10 million cycles minimum mechanical 20 Amp Resistive @ 277 Vac Operating Temperature: -30 to 140° F 20 Amp Ballast @ 277 Vac (N/O) Humidity Range: 5 to 95% (noncondensing) 10 Amp Ballast @ 277Vac (N/C) Red LED: Relay Status / Learn Mode Status (Flashing) 16 Amp Electronic Ballast @ 277 Vac (N/O) Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.75" NPT nipple 10 Amp Tungsten @ 120 Vac (N/O) Housing Detail: See Housing B in housing guide for demensions 770 VA Pilot Duty @ 120 Vac Wires: 16, 600V Rated 1,110 VA Pilot Duty @ 277 Vac Approvals: UL Listed, UL916, C-UL, RoHs 2 HP @ 277 Vac Agency Compliance: FCCID: SZV-TCM320U 1 HP @ 120 Vac IC: 5713A-TCM320U Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Frequency: 902 MHz Power Input Ratings: 39 mA max @ 120-277Vac Analog Output Ratings: 0-10Vdc, 10mA Sourcing/ 50mA Sinking Receiver Sensitivity: -93 dBm typical Conducted Power: 5 mW typical Built-in Switch Modes: Alarm, Repeater, Delay, Dimming, Rocker, Momentary, and Toggle Origin: Made of US and non-US parts Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft. · Open area transmission could be farther. Consult factory for more information. · Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used. · For setup instructions, see website. WIRELESS CONTROL RELAYS WITH TWO-WAY COMMUNICATION RIBW01C-EN3 EnOcean 902 MHz Wireless Relay, Receiver/ Repeater, 5 Amp SPST-N/O, 120 Vac Power Input, NEMA 1 Housing RIBW02C-EN3 EnOcean 902 MHz Wireless Relay, Receiver/ Repeater, 5 Amp SPST-N/O, 208-277 Vac Power Input, NEMA 1 Housing WIRELESS DEVICES Org N/O Blk 120 Vac Wireless Org Receiver N/O Wht Control Neutral Circuit Org N/O Blk 208-277 Vac Wireless Org Red Neutral or Receiver Control N/O Other Phase Circuit SMALLER SIZE DESIGN TO FIT INSIDE BALLAST HOUSING OF FLUORESCENT LIGHT FIXTURE. SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Contact Ratings: Expected Relay Life: 10 million cycles minimum mechanical 5 Amp Ballast @ 120/277 Vac Operating Temperature: -30 to 140° F 5 Amp Tungsten @ 120 Vac Humidity Range: 5 to 95% (noncondensing) 5 Amp Electronic Ballast @ 120 Vac Red LED: Relay Status / Learn Mode Status (Flashing) Dimensions: 1.68"H x 4.58"W x 1.18"D Housing Detail: See Housing E in housing guide for demensions Wires: 16, 600V Rated Power Input Ratings: 75 mA @ 120 Vac ; 60 Hz (RIBW01C-EN3) 100 mA @ 208-277 Vac ; 60 Hz (RIBW02C-EN3) Approvals: UL Listed, UL916, C-UL, RoHS Agency Compliance: FCCID: SZV-TCM320U ; IC: 5713A-TCM320U Gold Flash: No Override Switch: No Frequency: 902 MHz Receiver Sensitivity: -93 dBm typical Conducted Power: 5 mW typical Built-in Switch Modes: Alarm, Repeater, Delay, Rocker, Momentary, and Toggle Origin: Made of US and non-US parts Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft. · Open area transmission could be farther. Consult factory for more information. · Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used. · Version 1.5 firmware or later implements Functional Devices, Inc.'s EnOcean® Manufacturer ID of 0x055. · For setup instructions, see website for -EN3 Series: www.functionaldevices.com/wp-content/uploads/2021/12/ B1867_393231.pdf 178 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® WIRELESS CONTROL PHASE ANGLE DIMMER RIBW01F600-EN3 EnOcean 902 MHz Wireless Phase Angle Dimmer, Receiver / Repeater, 120 Vac Power Input, 600W Rated, Dimming Mode Selectable, NEMA 1 Housing Blk 120 Vac DIMMER HAS BUILT-IN REPEATER FUNCTION. DIMMER RECEIVES SIGNAL FROM WIRELESS TRANSMITTER AND REBROADCASTS THE SIGNAL TO THE NEXT RELAY RECEIVER. Wht Neutral Red Dimmed Hot Wireless Receiver Control Circuit SPECIFICATIONS Operating Temperature: -30 to 122 F Humidity Range: 5 to 95% (noncondensing) Red LED: Learn Mode Status (Flashing) / Dim Mode Status Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for demensions Wires: 16", 600V rated Approvals: UL Listed, UL916, C-UL, RoHS Agency Compliance: FCCID: SZV-TCM320U IC: 5713A-TCM320U Housing Rating: UL Accepted, NEMA 1 Frequency: 902 MHz Max Lighting Load: 600W Incndescent/Halogen Recommended 300W for other dimmable lighting loads Selectable Dimming Mode: Yes Selectable Low Dim Threshold: Yes Origin: Made of US and non-US parts Power Input Ratings: 100mA @ 120 Vac; 60Hz Clear Learn Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft. · Open area transmission could be farther. Consult factory for more information. · Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used. · Version 1.5 firmware or later implements Functional Devices, Inc.'s EnOcean® Manufacturer ID of 0x055. · Not for use with Magnetic Low Voltage (MLV) loads. TYPICAL APPLICATION EnOcean Enabled Transmitter RIBW01F600-EN3 Black White Red 120Vac Power Phase Dimmable Lighting Load WIRELESS DEVICES (800) 888-5538 | www.functionaldevices.com 179 WIRELESS ROCKER SWITCH TRANSMITTER & COVER PLATE WWS2-EN3 EnOcean 902 MHz Wireless Wall Transmitter Switch with Barrier and Cover Plate, White Includes Cover Plate. SPECIFICATIONS Operating Modes: On/Off, Toggle, Scene control Power Supply: Powered by finger press (Electrodynamic Energy Harvester) Frequency: 902 MHz Antenna: Integrated antenna, 6.4 cm Transmission Power: Max. 10mW EIRP Energy Bowtravel/Operating Force: 50,000 actuations tested to EN60669 / VDE 0632 Operating Temperature: -25 to 65° C Relative Humidity 5 to 92% (noncondensing) Dimensions: 2.75H x 4.50W x 0.8D Approvals: RoHS Agency Compliance: · Switch · Barrier Plate FCC ID: SZV-PTM210U Certified to UL514D IC: 5713A-PTM210U CSA C22.2 #42-1-13 Notes: · Control one load or one group of loads with a single rocker style Wireless Switch Transmitter. · Typical range: 50-150 ft. · Open area transmission could be farther. Consult factory for more information. · Mounting · Includes barrier plate and mounts to electrical wall boxes (screws included). · Alternate surface mount accessory AWSTFM to install on any surface using double sided tape or VelcroTM (sold separately). · For use with EN3 Series Relays. · EEP F6-02-02 WIRELESS SOLAR DOOR / WINDOW TRANSMITTER WDWS2-EN3 EnOcean 902 MHz Wireless Solar Door / Window Transmitter Switch SPECIFICATIONS Minimum Illumination: 400 lux hours per day e.g. 100 lux for 4 hours or 200 lux for 2 hours Start-up Time: Less than 2.5 min @ 400 lux Operating Life in Darkness (after full charge): Min 10 days signs-of-life only Operating Life in Darkness (with backup battery): Min 5 years Maximum Sensor Gap: 0.16" (4mm) Dimensions : 3.00" L x 0.87"W x 0.59" D (76mm x 22mm x 15mm) Dimensions (with mounting plate): 3.15" L x 0.94"W x 0.73" D (80mm x 24mm x 19mm) Drill Distance: 2.05" (52mm) Environment: Indoor use only -4 to 140 F (-20 to 60 C) 5 to 93% relative humidity (noncondensing) Approvals: RoHS Agency Compliance: FCC ID: SZV-STM 320U IC: 5713A-STM 320U Notes: · Typical range: 100 ft. · Open area transmission could be farther. Consult factory for more information. · Only for use with EN3 Series relays. · EEP D5-00-01 WIRELESS KEYCARD TRANSMITTER SWITCH WKC-EN3 EnOcean 902 MHz Wireless Key Card Transmitter Switch SPECIFICATIONS Power Supply: Mechanical energy harvesting (power is generated by inserting the card into the key card switch) Inputs/Outputs: Slot for standard hotel key card: (2.125"W x 3.375" H x 0.034" D) Radio Frequency (RF) transmitter RF Communications: EnOcean 902 MHz Transmission Range: 80ft. EnOcean Equipment Profile (EEP): F6-04-01 RF Transmission: On key card insertion or removal Installation: Surface mounted on wall (using included mounting screws) Dimensions: 4.72" H x 3.8"W x .43" D (at edge) Environment: Indoor use only 32° to 131° F (0° to 55° C) 5% to 95% relative humidity (non-condensing) Agency Compliance: FCC: SZV-PTM330U IC: 5713A-PTM330U Approvals: RoHS www.functionaldevices.com/wp-content/uploads/2022/04/B1970_393238.pdf 180 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® WIRELESS DEVICES WIRELESS OCCUPANCY / VACANCY SENSOR WVSCM-EN3 EnOcean 902 MHz Wireless Vacancy / Occupancy Sensor, Ceiling Mount SPECIFICATIONS RF Transmission Range: 80 ft. Motion Sensing Range: 34 ft. diameter (refer to coverage diagrams) Startup Charge Times First Motion Transmission / Linking: 5 minutes at 200 lux Motion LED Blink Light / Walk Test Modes: 1.5 hours at 2000 lux Sustaining Charge Time: 3 hours per 24 hours at 200 lux Time to Full Charge: 25 hours at 200 lux Operating Life in Total Darkness: 80 hours (after full charge) Minimum Operating Light: 50 lux (for auto-off only) Motion Transmission Interval: 2 minutes Unoccupied Transmission: 10 and 30 minutes since last motion Dimensions: 6.3" L x 2.35"W x 1.47" D (160 mm x 60 mm x 37 mm) Mounting Height: 7-10 feet recommended Environment: Indoor use only 14° to 104° F (-10° to 40° C) 20 to 95% relative humidity (noncondensing) Approvals: RoHS, R&TTE Agency Compliance: FCC: SZV-STM300U IC: 5713A-STM300U Notes: · Only for use with EN3 Series relays. · EEP A5-07-01 https://www.functionaldevices.com/wp-content/uploads/2022/04/B2104_393249.pdf WIRELESS OCCUPANCY / VACANCY SENSOR WVSWM-EN3 EnOcean 902 MHz Wireless Vacancy / Occupancy Sensor, Wall Mount SPECIFICATIONS RF Transmission Range: 80 ft. Motion Sensing Range: Up to 100 ft. (refer to coverage diagrams) Startup Charge Times First Motion Transmission / Linking: 5 minutes at 200 lux Motion LED Blink Light / Walk Test Modes: 1.5 hours at 2000 lux Sustaining Charge Time: 3 hours per 24 hours at 200 lux Time to Full Charge: 25 hours at 200 lux Operating Life in Total Darkness: 80 hours (after full charge) Minimum Operating Light: 50 lux (for auto-off only) Motion Transmission Interval: 2 minutes Unoccupied Transmission: 10 and 30 minutes since last motion Dimensions: 5.83" L x 2.52"W x 1.8" D (148 mm x 64 mm x 45.7 mm) Mounting Height: 6-8 feet recommended Environment: Indoor use only 14° to 104° F (-10° to 40° C) 20 to 95% relative humidity (noncondensing) Approvals: RoHS, R&TTE Agency Compliance: FCC ID: SZV-STM300U IC: 5713A-STM300U Notes: · Only for use with EN3 Series relays. · EEP A5-07-01 WIRELESS DEVICES (800) 888-5538 | www.functionaldevices.com 181 WIRELESS OCCUPANCY / VACANCY SENSOR WVSUS-EN3 EnOcean® Enabled Wireless Occupancy / Vacancy Sensor, Ceiling Mount, 902 MHz SPECIFICATIONS Solar Supply: Integrated Solar Cells Operational Light Level: 65 lux (6 fc) Start Up Period < 2 minutes @ 65 lux Battery Supply: CR1632 coin cell battery Battery Life Expectancy: Shelf life as defined by the battery manufacturer or 5 years, whichever occurs first Radio Frequency: 902 MHz Antenna: Integrated whip Transmission Range: 24 m (80 ft.) - commercial office spaces(typical), up 100 m (330ft.) line of sight Telegram Transmission: Vacancy - on heartbeat Occupancy - Immediately upon motion detection or heartbeat Telegram Heartbeat: 100 seconds min. - 1000 seconds max. Inputs: Teach button, Test button Detection Area: A lens - 450 ft2 at 8 ft. - 800 ft2 at 10 ft B lens - 1,800 ft2 at 8 ft. - 3000 ft2 at 10 ft Operating Temperature: -10°C to 45°C(14°F to 113°F) Storage Temperature: -25°C to 65°C(-13°F to 149°F) Relative Humidity: 5% to 92% RH(non-condensing) Dimensions: 98.0 mm. x 25.5 mm. (3.86" x 1.00") Mounting: Integrated magnets, wire bracket, screws(not supplied), double sided tape (not supplied) Agency Compliance: FCC: 15.231 IC: RSS-210 Origin: Made of US and non- US parts Notes: · Only for use with EN3 Series relays. · EEP A5-07-01 SINGLE SURFACE MOUNT BACKPLATE KIT AWSTFM Flush Surface Mount Backplate Kit for WWS2-EN3, White SPECIFICATIONS Includes: (2) Switch-mounting screws For Use With: WWS2-EN3, FDLTS2 Approvals: CE Approved, RoHS Origin: Made of US and non-US parts Installation Instructions: Mount switch to any surface by using double sided tape or VelcroTM (not included.) ROCKER SWITCH COVER PLATE WSTP-W Wall Switch Plate Replacement, White SPECIFICATIONS Approvals: CE, RoHS For use with: WWS-EN3, WWS2-EN3 Origin: Made of US and non-US parts WIRELESS DEVICES 182 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® MH5503L MH3803L MH4404L ENCLOSURES Metal & Plastic Enclosures · NEMA 1 or NEMA 4/4X rated · Various sizes available · Multiple knockouts on many models · Vertically and horizontally stackable · Available with perforated steel or polymetal sub-panels or track mount · Several cover and door configurations · Grey finish · Blue housings available (consult factory) · Made in the USA · UL Listed MH3300 MH1210 ENCLOSURES (800) 888-5538 | www.functionaldevices.com 183 ENCLOSURES ENCLOSURES MODEL # PE6000 · PE6010 · PE6020 · PE6000-N4 · PE6010-N4 · PE6020-N4 · MH1000 · MH1010 · MH1020 · MH1200 · MH1210 · MH1220 · MH2204-N4 · MH3100-M1 · MH3204-N4 · MH3300 · MH3300K · MH3303 · MH3304 · MH3303K · MH3304K · MH3500 · MH3510 · MH3520 · MH3800 · MH3810 · MH3820 · MH3803S · MH3803L · MH3804S · MH3804L · MH4400 · MH4403L · MH4404L · MH4604S · MH5500 · MH5503L · MH5504L · MH5800 · MH5803L · MH5804L · ENCLOSURE PE6000 PE6000 PE6000 PE6000-N4 PE6000-N4 PE6000-N4 MH1000 MH1000 MH1000 MH1200 MH1200 MH1200 MH3300 MH3300K MH3300 MH3300 MH3300K MH3300K MH3500 MH3500 MH3500 MH3800 MH3800 MH3800 MH3800 MH3800 MH3800 MH3800 MH4400 MH4400 MH4400 MH4600 MH5500 MH5500 MH5500 MH5800 MH5800 MH5800 HOUSING MATERIAL Plastic Plastic Plastic Plastic Plastic Plastic Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal SUB-PANEL 14 Gauge Steel 14 Gauge Steel SP3303 # SP3304 ^ SP3303 # SP3304 ^ SP3803S # SP3803L # SP3804S ^ SP3804L ^ SP4403L # SP4404L ^ Perforated Steel SP5503L # SP5504L ^ SP5803L # SP5804L ^ TRACK MOUNT MT4-4 MT212-6 MT4-4 MT212-6 MT4-12 MT212-12 MT4-8 MT212-8 6 Threaded Studs MT4-24 MT212-24 MT4-18 MT212-18 NEMA RATING NEMA 1 NEMA 1 NEMA 1 NEMA 4/4X NEMA 4/4X NEMA 4/4X NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 4/4X COVER / DOOR Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Hinge Key Latch Door HEIGHT 4.28 4.28 4.28 4.28 4.28 4.28 14.50 14.50" 14.50" 8.30" 8.30" 8.30" 9.84 WIDTH 7.00 7.00 7.00 7.00 7.00 7.00 7.70 7.70" 7.70" 7.70" 7.70" 7.70" 7.87 NEMA 1 Screw Down Cover 12.00 12.00 NEMA 4/4X NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 Hinge Key Latch Door Vertical Lift Screw Down Cover Vertical Lift Key Latch Vertical Lift Screw Down Cover Vertical Lift Screw Down Cover Vertical Lift Key Latch Vertical Lift Key Latch Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door 15.75 12.50 12.50 12.50 12.50 12.50 12.50 24.50 24.50 24.50 24.50 24.50 24.50 24.50 24.50 24.50 24.50 18.00 18.00 18.00 20.00 25.00 25.00 25.00 36.00 36.00 36.00 11.81 12.50 12.50 12.50 12.50 12.50 12.50 10.25 10.25 10.25 12.50 12.50 12.50 12.50 12.50 12.50 12.50 18.00 18.00 18.00 16.15 25.00 25.00 25.00 25.00 25.00 25.00 DEPTH 2.00 2.00 2.00 2.00 2.00 2.00 3.90 3.90" 3.90" 3.90" 3.90" 3.90" 3.98 GAUGE 18 18 18 18 18 18 16 6.00 16 5.91 16 7.00 18 7.00 18 7.00 18 7.00 18 7.00 18 7.00 18 3.90 18 3.90 18 3.90 18 6.50 18 6.50 18 6.50 18 6.50 18 6.50 18 6.50 18 6.50 18 7.00 16 7.00 16 7.00 16 6.72 14 9.50 14 9.50 14 9.50 14 9.50 14 9.50 14 9.50 14 SPEC PAGE 185 185 185 185 185 185 185 185 185 185 185 185 186 186 186 187 187 187 187 187 187 187 187 187 187 187 187 187 187 187 187 188 188 188 188 188 188 188 189 189 189 MH3300 SERIES # Polymetal 11.33"H x 11.40"W ^ Perforated Steel 11.33"H x 11.40"W MH3800 SERIES # Polymetal Model S: 19.00"H x 11.75"W Model L: 23.00"H x 11.75"W ^ Perforated Steel Model S: 19.00"H x 11.75"W Model L: 23.00"H x 11.75"W MH4400 SERIES # Polymetal 16.875"H x 15.75"W ^ Perforated Steel 16.875"H x 15.75"W MH5500 SERIES # Polymetal 23.00"H x 22.50"W ^ Perforated Steel 23.00"H x 22.50"W = UL Listed - see data sheet for specific Listing MH5800 SERIES # Polymetal 34.125"H x 22.50"W ^ Perforated Steel 34.125"H x 22.50"W 184 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® ENCLOSURES ENCLOSURES PE6000 Series Plastic Housing Series, NEMA 1, 0.75" NPT Nipple, 4.28" H x 7.00"W x 2.00" D 7.00" 2.00" 7.00" 2.00" 4.28" 4.28" SPECIFICATIONS Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1, Also available NEMA 4 / 4X MT212-6 Plastic Snap Track 7.00" MT4-4 Plastic Snap Track 4.28" 2.00" PE6000 SERIES ASSEMBLIES Model # Enclosure Plastic Snap Track NEMA Type PE6000 PE6000 NEMA 1 PE6010 PE6000 MT4-4 (4.00"W) NEMA 1 PE6020 PE6000 MT212-6 (2.75"W) NEMA 1 PE6000-N4 PE6000-N4 NEMA 4/4X PE6010-N4 PE6000-N4 MT4-4 (4.00"W) NEMA 4/4X PE6020-N4 PE6000-N4 MT212-6 (2.75"W) NEMA 4/4X Housing Detail: See Housing D in housing guide for dimensions Origin: Made of US and non-US parts Notes: · Comes with transparent lid. To order with gray opaque lid, add "-GY" to end of model number. ENCLOSURES MH1000 Series Metal Housing Series, NEMA 1, 14.5" H x 7.7" W x 3.9" D MH1000 SERIES ASSEMBLIES 7.70" 5.70" Model # MH1000 Enclosure MH1000 Plastic Snap Track MH1010 MH1000 MT4-12 (4.00"W) MH1020 MH1000 MT212-12 (2.75"W) 14.50" 11.50" 14.50" ENCLOSURES 3.90" 7.70" SPECIFICATIONS Construction: 18 Gauge Steel Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts Notes: · Consult factory for custom colors for large orders. 8.30" 5.30" 8.30" ENCLOSURES MH1200 Series Metal Housing, NEMA 1, 8.3" H x 7.7" W x 3.9" D 7.70" 5.70" MH1200 SERIES ASSEMBLIES Model # Enclosure Plastic Snap Track MH1200 MH1200 MH1210 MH1200 MT4-8 (4.00"W) MH1220 MH1200 MT212-8 (2.75"W) 3.90" 7.70" SPECIFICATIONS Construction: 18 Gauge Steel Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts Notes: · Consult factory for custom colors for large orders. (800) 888-5538 | www.functionaldevices.com 185 ENCLOSURES MH2204-N4 Metal Housing, NEMA 4/4X, 9.84" H x 7.87" W x 3.98" D 3.98" 7.880" 6.420" 7.870" 5.928" 14 Gauge Steel Sub-Panel 4.500" 9.840" 11.140" 8.580" 4 Brackets .437" x .687" Oblong SPECIFICATIONS Construction: 16 Gauge Steel Cover Type: Hinge Key Latch Door Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts ENCLOSURES MH3100-M1 Metal Housing, NEMA 1, 12.00 H x 12.00 W x 6.00 D, Mounting Option 1 1/4"-20 Threaded Stud 1.00" H Max. 8-32 Threaded Stud .375"H 12.00" 6.00" 12.00" MH3100-M1 ASSEMBLY Model # Enclosure Plastic Snap Track MH3100-M1 * MH3100 6 Threaded Studs MH3100-M1 + PSMN500A = PSH500A MH3100-M1 + PSMN300A = PSH300A 12.00" SPECIFICATIONS Construction: 16 Gauge Steel. Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE, RoHS Origin Made of US and non-US parts ENCLOSURES MH3204-N4 Metal Housing, NEMA 4/4X,15.75" H x 11.81" W x 5.91" D Notes: · To convert panel-mounted power supply to enclosed, simply remove the sub-panel and mount to enclosure with provided screw pack. * 5.910" 11.811" 10.352" 11.811" 9.86" 14 Gauge Steel Sub-Panel 4 Brackets .437" x .687" Oblong SPECIFICATIONS Construction: 16 Gauge Steel Cover Type: Hinge Key Latch Door Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts 186 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® ENCLOSURES 6.355" 15.75" 16.93" 14.37" 12.75" ENCLOSURES MH3300 Series Metal Housing, NEMA 1, 12.5 H x 12.5 W x 7.0 D 12.50" 12.50" 12.50" 7.00" MH3300 SERIES ASSEMBLIES Model # Enclosure Cover Type Sub-Panel MH3300 MH3300 Vertical Lift Screw Down MH3300K MH3303 MH3304 MH3303K MH3304K MH3300K MH3300 MH3300 MH3300K MH3300K Vertical Lift Key Latch Vertical Lift Screw Down Vertical Lift Screw Down Vertical Lift Key Latch Vertical Lift Key Latch SP3303 1 SP3304 2 SP3303 1 SP3304 2 1 = Polymetal 11.33" H x 11.40" W 2 = Perforated Steel 11.33" H x 11.40" W SPECIFICATIONS Construction: 18 Gauge Steel Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts ENCLOSURES MH3500 Series Metal Housing, NEMA 1, 24.5" H x 10.25" W x 3.9" D 10.25" 8.35" 10.25" Notes: · Consult factory for custom colors for large orders. MH3500 SERIES ASSEMBLIES Model # Enclosure Plastic Snap Track MH3500 MH3500 MH3510 MH3500 MT4-24 (4.00"W) MH3520 MH3500 MT212-24 (2.75"W) 22.00" 24.50" ENCLOSURES 3.90" SPECIFICATIONS Construction: 18 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. ENCLOSURES MH3800 Series Metal Housing, NEMA 1, 24.5" H x 12.5" W x 6.5" D 10.60" 12.50" 22.00" 24.50" 6.50" 12.50" MH3800 SERIES ASSEMBLIES Model # Enclosure Plastic Snap Track / Sub-Panel MH3800 MH3800 MH3800-BL MH3803L-BL MH3803S-BL MH3810 MH3800 MH3800 MH3800 MH3800 SP3803L 1 SP3803S 2 MT4-18 (4.00"W) MH3820 MH3803S MH3803L MH3804S MH3804L MH3800 MH3800 MH3800 MH3800 MH3800 MT212-18 (2.75"W) SP3803S 1 SP3803L 1 SP3804S 2 SP3804L 2 Color option Blue Blue Blue 1 = Polymetal Model S: 19.00" H x 11.75" W Model L: 23.00" H x 11.75" W 2 = Perforated Steel Model S: 19.00" H x 11.75" W Model L: 23.00" H x 11.75" W SPECIFICATIONS Construction: 18 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. (800) 888-5538 | www.functionaldevices.com 187 ENCLOSURES MH4400 Series Metal Housing, NEMA 1, 18.0" H x 18.0" W x 7.0" D 18.00" 18.00" 18.00" 13.50" 16.00" MH4400 SERIES ASSEMBLIES Model # Enclosure Sub-Panel MH4400 MH4403L MH4404L MH4400 MH4400 MH4400 SP4403L 1 SP4404L 2 1 = Polymetal 16.875" H x 15.75" W 2 = Perforated Steel 16.875" H x 15.75" W 7.125" SPECIFICATIONS Construction: 16 Gauge Steel Cover Type: Full Hinge Key Latch Door Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. ENCLOSURES MH4604S Metal Housing, NEMA 1, 20.0" H x 16.15" W x 6.72" D with SP4604S Sub-Panel 16.15" 16.15" 20.00" 17.50" ENCLOSURES 14.25" 6.72" SPECIFICATIONS Construction: 14 Gauge Steel Cover Type: Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Subpanel: Perforated Steel (14.87" x 14.62") Origin: Made of US and non-US parts Notes: · Consult factory for custom colors for large orders. ENCLOSURES MH5500 Series Metal Housing, NEMA 1, 25.0" H x 25.0" W x 9.5" D 25.00" 25.00" 25.00" 22.50" 9.50" 23.10" SPECIFICATIONS Construction: 14 Gauge Steel Cover Type: Full Hinge Key Latch Door Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts MH5500 SERIES ASSEMBLIES Model # MH5500 MH5503L MH5504L Enclosure MH5500 MH5500 MH5500 Sub-Panel SP5503L 1 SP5504L 2 1 = Polymetal 2 = Perforated Steel 23.00" H x 22.50" W 23.00" H x 22.50" W Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. 188 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® ENCLOSURES MH5800 Series Metal Housing, NEMA 1, 36.0" H x 25.0" W x 9.5" D 25.00" 25.00" 36.00" 33.50" 9.50" 23.10" SPECIFICATIONS Construction: 14 Gauge Steel Cover Type: Full Hinge Key Latch Door Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts MH5800 SERIES ASSEMBLIES Model # Enclosure Sub-Panel MH5800 MH5803L MH5804L MH5800 MH5800 MH5800 SP5803L 1 SP5804L 2 1 = Polymetal 2 = Perforated Steel 34.125" H x 22.50" W 34.125" H x 22.50" W Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. ENCLOSURES (800) 888-5538 | www.functionaldevices.com 189 SP3303 MT4-6 ADIN35 & ADIN35ES SP3804S ACCESSORIES Sub-Panels Two types of sub-panel material are available: polymetal and perforated steel. Both the polymetal and perforated steel sub-panels are Plenum Rated and designed to mount in "MH" metal housing models. The mounting holes are pre-drilled and ready to install. Sub-panels can be ordered pre-installed in your choice of "MH" enclosure. See general specifications of pre-assembled enclosure models on page 77. Replacement Parts Replacement parts are available for several products including remote sensors, socket relays, and more. Mounting Supplies Mounting options include plastic track for snap-mounting circuit boards. One style of track can be mounted to the back surface of any cabinet and is available in 4.00" or 2.75" widths. Another style of track, AdapTrack®, snaps onto any of the three most popular DIN rails. In turn, it can accomodate a 4.00" wide circuit board. Perforated DIN rail and end stops are also available. 190 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® ACCESSORIES ACCESSORIES SUB-PANELS MODEL # SP3303 SP3304 SP3803S SP3803L SP3804S SP3804L SP4403L SP4404L SP5503L SP5504L SP5803L SP5804L USE WITH ENCLOSURE MH3300 or MH3300K MH3300 or MH3300K MH3800 MH3800 MH3800 MH3800 MH4400 MH4400 MH5500 MH5500 MH5800 MH5800 MOUNTING SUPPLIES MODEL # MT212-2 · MT212-4 · MT212-6 · MT212-8 · MT212-12 · MT212-18 · MT212-24 · MT212-48 · MT4-2 · MT4-4 · MT4-6 · MT4-8 · MT4-10 · MT4-12 · MT4-18 · MT4-24 · MT4-48 · AT4-2 · AT4-6 · AT4-12 · AT4-24 · AT4-48 · ADIN35 WIDTH 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 35 mm MATERIAL Polymetal Perforated Steel Polymetal Polymetal Perforated Steel Perforated Steel Polymetal Perforated Steel Polymetal Perforated Steel Polymetal Perforated Steel LENGTH 2.00" 4.00" 6.00" 8.00" 12.00" 18.00" 24.00" 48.00" 2.00" 4.00" 6.00" 8.00" 10.00" 12.00" 18.00" 24.00" 48.00" 2.00" 6.00" 12.00" 24.00" 48.00" 7.5 mm HEIGHT 11.330 11.330 19.000 23.000 19.000 23.000 16.875 16.875 23.000 23.000 34.125 34.125 WIDTH 11.400 11.400 11.750 11.750 11.750 11.750 15.750 15.750 22.500 22.500 22.500 22.500 THICKNESS .130 .250 .130 .130 .250 .250 .130 .250 .130 .250 .130 .250 MOUNTING AREA 129.16 square inches 129.16 square inches 223.25 square inches 270.25 square inches 223.25 square inches 270.25 square inches 265.78 square inches 265.78 square inches 517.50 square inches 517.50 square inches 767.81 square inches 767.81 square inches SPEC PAGE 192 192 192 193 193 193 194 194 194 195 195 196 TRACK TYPE Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track AdapTrack® for DIN rail AdapTrack® for DIN rail AdapTrack® for DIN rail AdapTrack® for DIN rail AdapTrack® for DIN rail Perforated DIN rail DISTANCE BETWEEN HOLE CENTERS 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 25 mm Center to Center SPEC PAGE 196 196 196 196 196 196 196 196 197 197 197 197 197 197 197 197 197 197 197 197 197 197 197 REPLACEMENT & MISCELLANEOUS PARTS MODEL # ADIN35ES APS53-TC APSB-TC AR24D ARL1C AXG AXGT AXK AXKT DS80625 KEYSET MKL-1 MKL-2 MKL-3 MKL-4 TS-AN TS-BC DESCRIPTION Pair of End Stops for 35mm DIN Rail Primary voltage terminal cover One terminal cover and two clips Replacement relays (3-pack) Replacement relays (3-pack) Split ring remote current sensor assembly (Wire Output) Split ring remote current sensor assembly (Terminal Output) Remote mini current sensor assembly (Wire Output) Remote mini current sensor assembly (Terminal Output) No. 8 x 5/8 Self-Tapping Drill Screws One set of 2 keys Locking key latch assembly Locking key-hook latch assembly Metal locking key latch assembly Coin locking key latch assembly Pluggable terminal strips Replacement pluggable terminal strips FOR USE WITH MODEL(S) ADIN35 Functional Devices 300 VA and 500 VA power supplies PSB100AB10, PSB40AB10 RIBR24D, RIBR24SD RIBRL1C, RIBRL1S, RIBRXLCA, RIBRXLCF, RIBRXLSA RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF Functional Devices polymetal sub-panels Functional Devices key latch metal enclosures Functional Devices metal enclosures except MH3300K Functional Devices MH3300K metal enclosures Functional Devices metal enclosures except MH3300K Functional Devices metal enclosures except MH3300K RIBAN12C, RIBAN24C RIBTW2401B-BC, RIBTW2402B-BC SPEC PAGE 198 198 198 198 199 199 199 199 200 200 200 200 200 200 200 200 = UL Component Recognized - see data sheet for specific Listing # = 32 mm x 15 mm asymmetrical DIN rail EN50035; 35 mm x 7.5 mm symmetrical DIN rail EN50022; 22.4 mm x 6.9 mm symmetrical NEMA A Series rail (800) 888-5538 | www.functionaldevices.com 191 ACCESSORIES SUB-PANEL SP3303 Polymetal Sub-Panel, 11.33" H x 11.40" W x 0.13" Thick, For use with MH3300 or MH3300K 11.4000" 11.3300" 10.2050" 2.5000" 6.4000" 2.5000" .5625" SPECIFICATIONS Mounting Area: 129.16 square Approvals: Plenum Rated Origin: Made of US and non-US parts Enclosure Assemblies: MH3303 MH3300 Enclosure with SP3303 Sub-Panel pre-mounted MH3303K MH3300K Enclosure with SP3303 Sub-Panel pre-mounted SUB-PANEL SP3304 Perforated Steel Sub-Panel, 11.33" H x 11.40"W x 0.25"Thick, For use with MH3300 or MH3300K 11.4000" 11.3300" 10.2050" 2.5000" 6.4000" 2.5000" .5625" SPECIFICATIONS Mounting Area: 129.16 square Approvals: Plenum Rated Origin: Made of US and non-US parts Enclosure Assemblies: MH3304 MH3300 Enclosure with SP3304 Sub-Panel pre-mounted MH3304K MH3300K Enclosure with SP3304 Sub-Panel pre-mounted SUB-PANEL SP3803S Polymetal Sub-Panel, 19.00" H x 11.75" W x 0.13" Thick, For use with MH3800 11.7500" 9.0000" 10.7500" .5000" 19.0000" 9.0000" 8.5000" .5000" SPECIFICATIONS Mounting Area: 223.25 square Enclosure Assemblies: MH3803S Approvals: Plenum Rated MH3800 Enclosure with SP3803S Origin: Made of US and non-US parts Sub-Panel pre-mounted 192 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® ACCESSORIES SUB-PANEL SP3803L Polymetal Sub-Panel, 23.00" H x 11.75" W x 0.13" Thick, For use with MH3800 11.7500" 4.5000" 10.7500" .5000" 9.000" 23.000" 9.000" 8.5000" .5000" SPECIFICATIONS Mounting Area: 270.25 square Enclosure Assemblies: MH3803L Approvals: Plenum Rated MH3800 Enclosure with SP3803L Origin: Made of US and non-US parts Sub-Panel pre-mounted SUB-PANEL SP3804S Perforated Steel Sub-Panel, 19.00" H x 11.75"W x 0.25"Thick, For use with MH3800 11.7500" 9.0000" 10.7500" .5000" 19.0000" 9.0000" 8.5000" .5000" SPECIFICATIONS Mounting Area: 223.25 square Enclosure Assemblies: MH3804S Approvals: Plenum Rated MH3800 Enclosure with SP3804S Origins: Made of US and non-US parts Sub-Panel pre-mounted SUB-PANEL SP3804L Perforated Steel Sub-Panel, 23.00" H x 11.75"W x 0.25"Thick, For use with MH3800 11.7500" 4.5000" 10.7500" .5000" 9.000" 23.000" 9.000" 8.5000" .5000" SPECIFICATIONS Mounting Area: 270.25 square Enclosure Assemblies: MH3804L Approvals: Plenum Rated MH3800 Enclosure with SP3304L Origin: Made of US and non-US parts Sub-Panel pre-mounted (800) 888-5538 | www.functionaldevices.com 193 ACCESSORIES SUB-PANEL SP4403L Polymetal Sub-Panel, 16.875" H x 15.750" W x 0.130" Thick, For use with MH4400 15.7500" 14.3750" .7500" 16.8750" 15.3750" .7500" SPECIFICATIONS Mounting Area: 265.78 square Enclosure Assemblies: MH4403L Approvals: Plenum Rated MH4400 Enclosure with SP4403L Origin: Made of US and non-US parts Sub-Panel pre-mounted SUB-PANEL SP4404L Perforated Steel Sub-Panel, 16.875" H x 15.750"W x 0.25"Thick, For use with MH4400 15.7500" 14.3750" .7500" 16.8750" 15.3750" .7500" SPECIFICATIONS Mounting Area: 265.78 square Enclosure Assemblies: MH4404L Approvals: Plenum Rated MH4400 Enclosure with SP4404L Origin: Made of US and non-US parts Sub-Panel pre-mounted SUB-PANEL SP5503L Polymetal Sub-Panel, 23.00" H x 22.50" W x 0.13" Thick, For use with MH5500 22.5000" 10.7500" 10.5000" 10.5000" .7500" 10.7500" ACCESSORIES 23.0000" .7500" SPECIFICATIONS Mounting Area: 517.50 square Enclosure Assemblies: MH5503L Approvals: Plenum Rated MH5500 Enclosure with SP5503L Origin: Made of US and non-US parts Sub-Panel pre-mounted 194 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® SUB-PANEL SP5504L Perforated Steel Sub-Panel, 23.00" H x 22.50"W x 0.25"Thick, For use with MH5500 22.5000" 10.7500" 10.5000" 10.5000" .7500" 23.0000" 10.7500" .7500" SPECIFICATIONS Mounting Area: 517.50 square Enclosure Assemblies: MH5504L Approvals: Plenum Rated MH5500 Enclosure with SP5504L Origin: Made of US and non-US parts Sub-Panel pre-mounted SUB-PANEL SP5803L Polymetal Sub-Panel, 34.00" H x 22.50" W x 0.13" Thick, For use with MH5800 22.5000" 10.5000" 10.5000" .7500" 16.2500" 34.1250" 16.2500" .7500" SPECIFICATIONS Mounting Area: 767.81 square Enclosure Assemblies: MH5803L Approvals: Plenum Rated MH5800 Enclosure with SP5803L Origin: Made of US and non-US parts Sub-Panel pre-mounted ACCESSORIES (800) 888-5538 | www.functionaldevices.com 195 SUB-PANEL SP5804L Perforated Steel Sub-Panel, 34.00" H x 22.50"W x 0.25"Thick, For use with MH5800 22.5000" 10.5000" 10.5000" .7500" 16.2500" 34.1250" 16.2500" .7500" SPECIFICATIONS Mounting Area: 767.81 square Enclosure Assemblies: MH5804L Approvals: Plenum Rated MH5800 Enclosure with SP5804L Origin: Made of US and non-US parts Sub-Panel pre-mounted MOUNTING TRACK MT212 Series 2.75 Wide Mounting Track for Relays, Current Sensors, and Power Supplies Length 2.75" 2.00" SPECIFICATIONS Flame Rated: 94-5V Approvals: UL Component Recognized, USA & Canada CE, RoHS Mounting: MT212 Series track can be screw-mounted to any flat surface to provide mounting for 2.75 wide track-mountable relays, current sensors, or power supplies. Origin: Made of US and non-US parts MT212 SERIES SELECTION GUIDE Model # Width Length Distance Between Hole Centers MT212-2 2.75 2.00 2.00 Center to Center MT212-4 2.75 4.00 2.00 Center to Center MT212-6 2.75 6.00 2.00 Center to Center MT212-8 2.75 8.00 2.00 Center to Center MT212-12 2.75 12.00 2.00 Center to Center MT212-18 2.75 18.00 2.00 Center to Center MT212-24 2.75 24.00 2.00 Center to Center MT212-48 2.75 48.00 2.00 Center to Center ACCESSORIES 196 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® 4.00" MOUNTING TRACK MT4 Series 4.00 Wide Mounting Track for Relays, Current Sensors, and Power Supplies Length 2.00" SPECIFICATIONS Flame Rated: 94-5V Approvals: UL Component Recognized, USA & Canada CE, RoHS Mounting: MT4 Series track can be screw-mounted to any flat surface to provide mounting for 4.00 wide track-mountable relays, current sensors, or power supplies. Origin: Made of US and non-US parts MOUNTING TRACK AT4 Series 4.00 Wide AdapTrack® for Relays, Current Sensors, and Power Supplies Length MT4 SERIES SELECTION GUIDE Model # Width Length Distance Between Hole Centers MT4-2 4.00 2.00 2.00 Center to Center MT4-4 4.00 4.00 2.00 Center to Center MT4-6 4.00 6.00 2.00 Center to Center MT4-8 4.00 8.00 2.00 Center to Center MT4-10 4.00 10.00 2.00" Center to Center MT4-12 4.00 12.00 2.00 Center to Center MT4-18 4.00 18.00 2.00 Center to Center MT4-24 4.00 24.00 2.00 Center to Center MT4-48 4.00 48.00 2.00 Center to Center 4.00" SPECIFICATIONS Flame Rated: 94-5V DIN Rail Sizes: 32 mm x 15 mm asymmetrical DIN rail EN50035 35 mm x 7.5 mm symmetrical DIN rail EN50022 22.4 mm x 6.9 mm symmetrical NEMA A Series rail Approvals: UL Component Recognized, USA & Canada CE, RoHS Mounting: AT4 Series AdapTrack® snaps onto the three most common DIN rail sizes to provide mounting for 4.00 wide track-mountable relays, current sensors, or power supplies. Origin: Made of US and non-US parts MOUNTING TRACK ADIN35 DIN Rail Perforated 35mm x 7.5mm x 1m Model # AT4-2 AT4-6 AT4-12 AT4-24 AT4-48 AT4 SERIES SELECTION GUIDE Width Length DIN Rail Sizes 4.00 2.00 3 Most Common (see general specs to the left) 4.00 6.00 3 Most Common (see general specs to the left) 4.00 12.00 3 Most Common (see general specs to the left) 4.00 24.00 3 Most Common (see general specs to the left) 4.00 48.00 3 Most Common (see general specs to the left) ACCESSORIES SPECIFICATIONS Approvals: CE Approved, RoHS, EN60715:2001 Materials: Steel galvanized and passivated with a thick layer Pair of end stops sold separately. (800) 888-5538 | www.functionaldevices.com 197 MOUNTING TRACK ADIN35ES End Stops for 35mm DIN Rail SPECIFICATIONS Approvals: CE Approved, RoHS, EN60715:2001 Materials: Polyamide 6.6 Dimensions: 32mm x 28mm x 8mm REPLACEMENT APS53-TC Terminal Cover for PSH500A and PSH300A SPECIFICATIONS Includes: (2) Self-Tapping Drill Screws for Installation For Use With: PSMN300A, PSMN300A-IC, PSMN500A, PSMN500A-IC, PSH300A, PSH300A-IC, PSH500A, PSH500A-IC Origin: Made of US and non-US parts REPLACEMENT APSB-TC 1 Terminal Cover and 2 Clips for PSB 4up-Terminal SPECIFICATIONS *Only For Only for Use With: PSB100AB10, PSB40AB10 Installation Instructions: Remove end screws. Position one clip on each outside screw. Insert screws through hole in clip. Snap cover onto clips. Origin: Made of US and non-US parts REPLACEMENT AR24D Pluggable Relays (3-pack), Replacement for RIBR24 Series SPECIFICATIONS Dimensions: 1.125" x 0.5" x 0.75": (One relay) 4.25" x 0.625" x 0.875" (Package of 3) *Only For Only for Use With: RIBR24D, RIBR24SD Purpose: Replacement relay Approvals: CE Approved, RoHS Origin: Made of US and non-US parts REPLACEMENT ARL1C Pluggable Relays (3-pack), Replacement for RIBRL & RIBRX Series SRPEEPCLIAFICCEAMTIEONNTS Dimensions: 1.125" x 0.5" x 1: (One relay) 4.25" x 0.625" x 1.125" (Package of 3) *Only For Only for Use With: RIBRL1C, RIBRL1S, RIBRXLCF, RIBRXLCA, RIBRXLSA Purpose: Replacement relay Approvals: CE Approved, RoHS Origin: Made of US and non-US parts ACCESSORIES 198 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® REPLACEMENT AXG Split Core Remote with Wires, Replacement for Any Damaged or Lost Sensor, for Use with Models Listed on Data Sheet SPECIFICATIONS Dimensions: (Inside) .52 x .52 (Outside) 2.52 x 2.00 x 1.75 *Only For Only for Use With: RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF Can replace any damaged or lost sensor. Purpose: For use with the models listed above. Origin: Made of US and non-US parts REPLACEMENT AXGT Split Core Remote with Terminals, Replacement for Any Damaged or Lost Sensor, for Use with Models Listed on Data Sheet SPECIFICATIONS Dimensions: (Inside) .52 x .52 (Outside) 2.52 x 2.00 x 1.75 *Only For Only for Use With: RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF Can replace any damaged or lost sensor. Purpose: For use with the models listed above. Origin: Made of US and non-US parts REPLACEMENT AXK Solid Core Remote with Wires, Replacement for Any Damaged or Lost Sensor, for Use with Models Listed on Data Sheet SPECIFICATIONS Dimensions: (Inside Diameter) .50 (Outside) 1.86 x 1.46 x 1.50 *Only For Only for Use With: RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF Can replace any damaged or lost sensor. Purpose: For use with the models listed above. Origin: Made of US and non-US parts REPLACEMENT AXKT Solid Core Remote with Terminals, Replacement for Any Damaged or Lost Sensor, for Use with Models Listed on Data Sheet SPECIFICATIONS Dimensions: (Inside Diameter) .50 (Outside) 2.05 x 1.46 x 1.50 *Only For Only for Use With: RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF Can replace any damaged or lost sensor. Purpose: For use with the models listed above. Origin: Made of US and non-US parts (800) 888-5538 | www.functionaldevices.com 199 ACCESSORIES SCREW SET DS80625 Number 8 Self-Tapping Drill Screws SPECIFICATIONS Size: No. 8 x 5/8 For Use With: All polymetal sub-panels Advantages: Self-tapping, eliminates mushrooming Weight: 0.004 Origin: Made of US and non-US parts LOCK ASSEMBLY MKL-1 Locking Key Latch Assembly for Use with All Metal Enclosures Except MH3300K SPECIFICATIONS Origin: Made of US and non-US parts LOCK ASSEMBLY MKL-3 Metal Locking Key Latch Assembly for Use with All Metal Enclosures Except MH3300K SPECIFICATIONS Origin: Made of US and non-US parts REPLACEMENT TS-AN Replacement Pluggable Terminal Strips for RIBAN Series SPECIFICATIONS *Only For Use With: RIBAN12C, RIBAN24C Installation Instructions: Plug the terminal strips into the headers found on the RIBAN Series product. Origin: Made of US and non-US parts KEY SET KEYSET Set of Two Metal Enclosure Replacement Keys SPECIFICATIONS Quantity: Two keys and one ring per set For Use With: Any of the key-lock enclosures Advantages: Works with any Functional Devices, Inc. key-lock enclosures Origin: Made of US and non-US parts LOCK ASSEMBLY MKL-2 Locking Key-Hook Latch Assembly for Use with MH3300K SPECIFICATIONS Origin: Made of US and non-US parts LOCK ASSEMBLY MKL-4 Coin Locking Key Latch Assembly for Use with All Metal Enclosures Except MH3300K SPECIFICATIONS Origin: Made of US and non-US parts REPLACEMENT TS-BC Replacement Pluggable Terminal Strips for RIBTW240*B-BC Series; one 2-up and one 5-up SPECIFICATIONS *Only For Use With: RIBTW2401B-BC, RIBTW2402B-BC Approvals: CE, RoHS Installation Instructions: Plug the terminal strips into the headers found on the RIBTW240*B-BC models. ACCESSORIES 200 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® HOUSING GUIDE 0.15" 2.80" 2.55" 1.70" 0.765" 0.50" NPT 0.2" 0.25" 2.125" 1.50" 0.55" 4.31" 3.31" 1.89" 2.39" 0.50" or 0.75 NPT 2.54" 1.81" 0.68" HOUSING A HOUSING B 4.00" .20" .20" 0.2" .20" .20" .44" .56" 0.50" NPT 4.00" .44" .56" 2.00" 1.81" 1.00" 2.00" 0.84" 0.86" 4.28" 7.00" 0.81" 2.00" 0.75" NPT HOUSING C red ("-rd") and NEMA 4 ("-N4") HOUSINGS Available. See our website for details. HOUSING D 1.09" 4.17" .20" 1.68" 1.40" 5.30" .20" 1.18" 4.58" 5.634" 4.9" 1.06" 1.68" .20" 4.00" 5.15" .20" 1.00" 1.32" 5.50" 1.28" HOUSING E HOUSING F HOUSING G Circuit Board H W D1 D2 Track 680957 HOUSING H 2.75" 2.00" 1.025" 2.43" 2.85" 2.90" 1.50" 2.36" 1.05" HOUSING I with Retaining Clip for 1/2 Knockout HOUSING J 3.88" .78" 2.76" HOUSING K (800) 888-5538 | www.functionaldevices.com 201 INDEX & RERENCES INDEX ADIN35 197 MH4404L 188 PSH100AWB10 112 PULS-PIM60-241 108 RIBHX24BF 97 ADIN35ES 198 MH4604S 188 PSH200A 114 PULS-PIM60-245 108 RIBL12B 65 APS53-TC 198 MH5500 188 PSH200AB10-LVC 118 PULS-PIM90-241 108 RIBL12BM 65 APSB-TC 198 MH5503L 188 PSH200A-LVC 116 PULS-PIM90-245 108 RIBL12SB 65 AR24D 198 MH5504L 188 PSH24DWB10 123 PULS-PIM90-245-L1 108 RIBL12SBM 65 ARL1C 198 MH5800 189 PSH2C2RB10 172 RIB013P 50 RIBL1C-DC 25 AT4-12 197 MH5803L 189 PSH2C2RB10-L 173 RIB01BDC 79 RIBL24B 66 AT4-2 197 MH5804L 189 PSH2RB10 169 RIB01P 49 RIBL24BM 66 AT4-24 197 MHP3903100A100AB10 121 PSH300A 114 RIB01P30 53 RIBL24SB 66 AT4-48 197 MHP3903100AB10 120 PSH300AB10-LVC 118 RIB01P30-S 53 RIBL24SBM 66 AT4-6 197 MHP3904100A100AB10 121 PSH300A-LVC 115 RIB01SBCDC 80 RIBL3C 23 AWSTFM 182 MHP3904100AB10 120 PSH40A 110 RIB01SBDC 80 RIBL4C 23 AXG 199 MHP4604100A100AB10 122 PSH40AB10 110 RIB023P 50 RIBLB 133 AXGT 199 MHP4604100AB10 121 PSH40AB10-EXT2 111 RIB02BDC 79 RIBLB-2 137 AXK 199 MKL-1 200 PSH40AW 110 RIB02P 49 RIBLB-4 137 AXKT 199 MKL-2 200 PSH40AWB10 110 RIB02P30 53 RIBLB-6 137 CT-025A1-333 163 MKL-3 200 PSH500A 113 RIB02SBCDC 80 RIBM013PN 62 CT-050A1-333 163 MKL-4 200 PSH500AB10-LVC 117 RIB02SBDC 80 RIBM013PNDC 83 CT-05A0-333 163 MOD1-07-33MV 163 PSH500A-LVC 115 RIB043P 51 RIBM01ZNDC 83 CT-100A1-333 163 MOD2-07-33MV 163 PSH600-UPS (Kit) 169 RIB04P 50 RIBM023PN 62 CT-100A2-333 163 MOD3-07-33MV 163 PSH600-UPS-BC (Kit) 174 RIB12C-FA 75 RIBM02ZNDC 83 CT-100A4-333 163 MT212-12 196 PSH600-UPS-STAT (Kit) 171 RIB12P 52 RIBM043PN 63 CT-200A4-333 163 MT212-18 196 PSH75A 111 RIB12P30 52 RIBM043PN-HD 63 CT-400A4-333 163 MT212-2 196 PSH75A75A 112 RIB12S-FA 75 RIBM12C 37 CT-600A4-333 163 MT212-24 196 PSH75A75AB10 112 RIB21CDC 79 RIBM12S 37 CTRL-PS 120 MT212-4 196 PSH75A75AW 112 RIB2401B 47 RIBM2401B 59 CTS-05A20-333 163 MT212-48 196 PSH75A75AWB10 112 RIB2401B2G 49 RIBM2401D 38 CTS-100A55-333 163 MT212-6 196 PSH75AB10 111 RIB2401C 26 RIBM2401SB 59 CTS-30A20-333 163 MT212-8 196 PSH75AW 111 RIB2401D 24 RIBM2401SBC 60 CTS-60A35-333 163 MT4-10 197 PSH75AWB10 111 RIB2401SB 47 RIBM2402B 59 DS80625 200 MT4-12 197 PSH850-UPS-STAT (Kit) 173 RIB2401SBC 48 RIBM2402D 38 KEYSET 200 MT4-18 197 PSM19A24DAS 125 RIB2402B 47 RIBM2402SB 59 MH1000 185 MT4-2 197 PSM20A12DAS 124 RIB2402B2G 49 RIBM2402SBC 60 MH1010 185 MT4-24 197 PSM24A24DAS 125 RIB2402D 24 RIBM243PN 61 MH1020 185 MT4-4 197 PSM2RB10 170 RIB2402SB 47 RIBM24C 37 MH1200 185 MT4-48 197 PSMN01SB10 166 RIB2402SBC 48 RIBM24S 37 MH1210 185 MT4-6 197 PSMN01SB4 166 RIB2421B 48 RIBM24ZL 61 MH1220 185 MT4-8 197 PSMN200A 114 RIB2421C 26 RIBM24ZN 60 MH2204-N4 186 PE6000 185 PSMN24DA 124 RIB2421SB 48 RIBME2401B 73 MH3100-M1 186 PE6000-N4 185 PSMN24DAS 124 RIB243P 51 RIBME2402B 73 MH3204-N4 186 PE6010 185 PSMN24SB10 166 RIB24C-FA 75 RIBMH1C 38 MH3300 187 PE6010-N4 185 PSMN24SB4 166 RIB24P 52 RIBMH1S 39 MH3300K 187 PE6020 185 PSMN2C2RB10 172 RIB24P30 52 RIBMH1SC 40 MH3303 187 PE6020-N4 185 PSMN2RB10 170 RIB24P-FA 76 RIBMH1SM-250 40 MH3303K 187 PSB100AB10 109 PSMN300A 114 RIB24S-FA 75 RIBMH2C 39 MH3304 187 PSB40AB10 109 PSMN40A 110 RIB24Z 51 RIBMN12C 41 MH3304K 187 PSC100AB10 109 PSMN40A24DS 125 RIB347P 50 RIBMN12C-FA 77 MH3500 187 PSC40AB10 109 PSMN40AS 110 RIBAN12C 36 RIBMN12S 41 MH3510 187 PSH100A 112 PSMN500A 113 RIBAN24C 36 RIBMN12S-FA 77 MH3520 187 PSH100A100A 113 PSMS1 167 RIBD01BDC 81 RIBMN2401D 43 MH3800 187 PSH100A100AB10 113 PSP24DA 122 RIBD02BDC 81 RIBMN24C 41 MH3803L 187 PSH100A100AB10-DC 126 PSPT2RB10 166 RIBD2421C 27 RIBMN24C-4T 42 MH3803S 187 PSH100A100AW 113 PSPT2RB4 166 RIBH1C 22 RIBMN24C-FA 77 MH3804L 187 PSH100A100AWB10 113 PSPW2RB10 166 RIBH1CW 30 RIBMN24Q2C 139 MH3804S 187 PSH100A24DWB10 123 PSPW2RB4 166 RIBH1S 23 RIBMN24Q3C 139 MH3810 187 PSH100AB10 112 PULS-ML15-241 108 RIBH1SC 25 RIBMN24Q4C 140 MH3820 187 PSH100AB10-DC 126 PULS-PIC120-241D 108 RIBH1SM-250 24 RIBMN24Q4C-PX 140 MH4400 188 PSH100AB10-EXT2 111 PULS-PIC240-241D 108 RIBH2C 22 RIBMN24S 41 MH4403L 188 PSH100AW 112 PULS-PIM36-241 108 RIBHX24BA 97 RIBMN24S-4T 42 202 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® INDEX & RERENCES INDEX RIBMN24S-FA 77 RIBT243B 57 RIBX243PF 103 RIBXLCRA 98 TR20VA004 129 RIBMN24S-J 42 RIBT243P 58 RIBX243PV 103 RIBXLCRF 98 TR20VA007 129 RIBMN24ZL 61 RIBT24B 54 RIBX24BA 100 RIBXLCV 98 TR240VA001 130 RIBMNA1D0 141 RIBT24B-FA 76 RIBX24BF 100 RIBXLSA 99 TR300VA002 130 RIBMNH1C 43 RIBT24P 57 RIBX24BV 100 RIBXLSEA 99 TR375VA001 130 RIBMNH1S 44 RIBT24SB 54 RIBX24SBA 100 RIBXLSEV 99 TR40VA001 129 RIBMNH1SM-250 44 RIBT24Z 58 RIBX24SBF 100 RIBXLSF 99 TR40VA001US 127 RIBMNLB 132 RIBTD2401B 56 RIBX24SBV 100 RIBXLSJA 99 TR40VA002 129 RIBMNLB-1 136 RIBTE01B 69 RIBXA 95 RIBXLSJF 99 TR40VA002US 127 RIBMNLB-2 135 RIBTE01P 72 RIBXF 95 RIBXLSRA 99 TR40VA003 129 RIBMNLB-2NO 138 RIBTE01P-S 73 RIBXG21A 89 RIBXLSRF 99 TR40VA004 129 RIBMNLB-4 135 RIBTE01SB 70 RIBXG21F 89 RIBXLSV 99 TR40VA013 129 RIBMNLB-4NO 138 RIBTE02B 69 RIBXG21TA 89 RIBXRA 95 TR40VA015 129 RIBMNLB-6 135 RIBTE02P 72 RIBXG21TF 89 RIBXRF 95 TR40VA022 129 RIBMNLB-6NO 138 RIBTE02P-S 73 RIBXG420-100 93 RIBXV 95 TR40VA040 129 RIBMNU1C 43 RIBTE02SB 71 RIBXG420-20 93 ROPE16-040A-07MV 163 TR50VA001 129 RIBMNU1S 44 RIBTE24B 68 RIBXG420-50 93 ROPE24-060A-07MV 163 TR50VA001US 127 RIBMNU1SM-250 44 RIBTE24P 71 RIBXGA 88 ROPE36-080A-07MV 163 TR50VA002 129 RIBMNW24B-BCAI 150 RIBTE24SB 70 RIBXGA-SCAL 88 ROPE48-100A-07MV 163 TR50VA003 129 RIBMNW24B-MBAI 156 RIBTELC 68 RIBXGF 88 SIB02S 167 TR50VA004 129 RIBMNWD12-BC 154 RIBTELS 68 RIBXGFL 88 SIB04S 167 TR50VA005 129 RIBMNWD12-BCDI 153 RIBTH1C 29 RIBXGHA 87 SIB05S 168 TR50VA005US 127 RIBMNWLB-7-BC 134 RIBTH1S 30 RIBXGHF 87 SIBLS 168 TR50VA006 129 RIBMNWX2401B-BC 146 RIBTH1SC 31 RIBXGHTA 87 SP3303 192 TR50VA007 129 RIBMNWX2402B-BC 148 RIBTH2C 29 RIBXGHTF 87 SP3304 192 TR50VA008 129 RIBMU1C 38 RIBTPM413-BC-KIT 162 RIBXGNTA 90 SP3803L 193 TR50VA009 129 RIBMU1S 39 RIBTU1C 29 RIBXGNTF 90 SP3803S 192 TR50VA014 129 RIBMU1SC 40 RIBTU1S 30 RIBXGNTF-125 90 SP3804L 193 TR50VA015 129 RIBMU1SM-250 40 RIBTU1SC 31 RIBXGT420-RMS 94 SP3804S 193 TR50VA016 129 RIBMU2C 39 RIBTU2C 29 RIBXGTA 88 SP4403L 194 TR50VA017 129 RIBMW24B-44-BC 155 RIBTW2401B-BC 144 RIBXGTA-ECM 88 SP4404L 194 TR50VA018 129 RIBMX24BA 105 RIBTW2402B-BC 145 RIBXGTA-NC 89 SP5503L 194 TR50VA019 129 RIBMX24BF 105 RIBTW24B-BCAI 151 RIBXGTA-SCAL 88 SP5504L 195 TR50VA022US 127 RIBMX24BV 105 RIBTW24B-BCAO 152 RIBXGTF 88 SP5803L 195 TR50VA027 129 RIBMX24SBA 105 RIBTW24B-MBAI 157 RIBXGTFL 88 SP5804L 196 TR75VA001 130 RIBMX24SBF 105 RIBTWX2401B-BC 147 RIBXGTF-NC 89 TR100VA001 130 TR75VA002 130 RIBMX24SBV 105 RIBTWX2402B-BC 149 RIBXGTV10 92 TR100VA001-28 130 TR75VA003 130 RIBPM413-BC 161 RIBU1C 22 RIBXGTV5 92 TR100VA001US 127 TR75VA004 130 RIBPM413-BC-KIT 160 RIBU1C-100PACK 22 RIBXGTV5-10 91 TR100VA002 130 TR75VA005 130 RIBR24D 35 RIBU1C-10PACK 22 RIBXJA 96 TR100VA002-20 130 TR75VA007 130 RIBR24D-NS 33 RIBU1C-25PACK 22 RIBXJF 96 TR100VA002US 127 TS-AN 200 RIBR24SD 35 RIBU1C-5PACK 22 RIBXK420-100 91 TR100VA004 130 TS-BC 200 RIBR24SD-NS 33 RIBU1CW 30 RIBXK420-20 91 TR100VA005 130 WDWS2-EN3 180 RIBRL1C 34 RIBU1S 23 RIBXK420-50 91 TR100VA008 130 WKC-EN3 180 RIBRL1C-NS 32 RIBU1SC 25 RIBXKA 87 TR100VA009 130 WSTP-W 182 RIBRL1S 34 RIBU1SM-250 24 RIBXKF 87 TR100VA009US 127 WVSCM-EN3 181 RIBRL1S-NS 32 RIBU2C 22 RIBXKNUTA 87 TR100VA015 130 WVSUS-EN3 182 RIBRXLCF 102 RIBU2S2 28 RIBXKTA 87 TR100VA026 130 WVSWM-EN3 181 RIBRXLCF-NS 101 RIBU2SC 28 RIBXKTF 87 TR100VA027 130 WWS2-EN3 180 RIBRXLSA 102 RIBW01B-EN3 177 RIBXKTV5-10 90 TR150VA001 130 RIBRXLSA-NS 101 RIBW01C-EN3 178 RIBXKTV5-100 90 TR150VA001-28 130 RIBT2401B 54 RIBW01F600-EN3 179 RIBXKTV5-20 90 TR150VA002 130 RIBT2401D 31 RIBW02C-EN3 178 RIBXKTV5-50 90 TR150VA008 130 RIBT2401SB 55 RIBW208B-EN3 177 RIBXLCA 98 TR175VA001 130 RIBT2401SBC 55 RIBW21BAO-EN3 178 RIBXLCEA 98 TR175VA002 130 RIBT2402B 54 RIBW240B-EN3 177 RIBXLCEV 98 TR175VA003 130 RIBT2402SB 55 RIBW24B-EN3 177 RIBXLCF 98 TR20VA001 129 RIBT2402SBC 55 RIBW277B-EN3 177 RIBXLCJA 98 TR20VA002 129 RIBT242B 57 RIBX243PA 104 RIBXLCJF 98 TR20VA003 129 (800) 888-5538 | www.functionaldevices.com 203 INDEX & RERENCES INDEX & RERENCES 204 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® (800) 888-5538 | www.functionaldevices.com 205 INDEX & RERENCES INDEX & RERENCES 206 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® (800) 888-5538 | www.functionaldevices.com 207 INDEX & RERENCES INDEX & RERENCES 208 Functional Devices, Inc. | Confidence & Peace of Mind in Every Box® RELAYS | CURRENT SENSORS | POWER SUPPLIES | TRANSFORMERS | POWER MONITORING | WIRELESS DEVICES VIEW OR DOWNLOAD THE CATALOG ON OUR WEBSITE POWER CONTROL | SPECIALTY PERIPHERAL CONTROLS | ACCESSORIES | ENCLOSURES | INTELLIGENT FIELD DEVICESAdobe InDesign 18.1 (Windows) Adobe PDF Library 17.0