CA2500A 2023 FDI-RIB-BAS Catalog
RELAYS | CURRENT SENSORS | POWER SUPPLIES | TRANSFORMERS | POWER MONITORING | WIRELESS DEVICES POWER CONTROL | SPECIALTY PERIPHERAL CONTROLS | ACCESSORIES | ENCLOSURES | INTELLIGENT FIELD DEVICES

NEW & FEATURED PRODUCTS
RELAYS
10-15 AMP: 19 | 20-30 AMP: 45 | LATCHING: 64 | LOW INPUT / OPTOISOLATED: 67 POLARIZED / ALARM: 74 | DRY CONTACT INPUT: 78
CURRENT SENSORS
SOLID & SPLIT CORE: 87 | TRANSDUCERS: 90 | T STYLE: 95 ENCLOSED & TRACK MOUNT RELAY AND SENSOR COMBINATIONS: 97
POWER SUPPLIES
40-100 VA AC: 109 | 200-500 VA AC: 113 | AC POWER SUPPLY KITS: 120 | DC: 122
TRANSFORMERS
U.S. MANUFACTURED: 127 | 20-375 VA: 129
SPECIALTY PERIPHERAL CONTROLS
FAN SAFETY ALARM CIRCUITS / GENERAL PURPOSE LOGIC BOARDS: 132 I/O EXPANDERS: 139 | MANUAL ANALOG OVERRIDE SWITCH: 141
INTELLIGENT FIELD DEVICES
BACNET® : 144 | MODBUS : 156
POWER MONITORING
POWER METERS: 160 | CURRENT TRANSFORMERS: 163
POWER CONTROL
POWER CONTROL CENTERS: 166 | TRACK MOUNT CIRCUIT BREAKER SWITCHES: 166 PREPACKAGED SWITCHES: 167 | UPS POWER SUPPLY KITS: 169
WIRELESS DEVICES
WIRELESS RELAY TRANSCEIVERS & RECEIVERS : 177 | WIRELESS PHASE ANGLE DIMMER : 179 WIRELESS TRANSMITTERS: 180 | WIRELESS VACANCY / OCCUPANCY SENSORS: 181
ENCLOSURES
PLASTIC: 185 | METAL: 185
ACCESSORIES
SUB-PANELS: 192 | MOUNTING SUPPLIES: 196 | REPLACEMENT PARTS: 198
INDEX & HOUSING GUIDE
HOUSING GUIDE: 201 | INDEX: 202

4 19 84 106 127 131 142 159 164 175 183 190 201

NEW & FEATURED

Functional Devices was incorporated on July 28, 1969 by Albert Rittmann, an engineer with a love for tinkering with electronics. The factory opened in September 1969 in Russiaville, Indiana.
Our first day at a second building, now the Company Headquarters, was in September of 2012 when shipping and power supplies manufacturing moved into the facility in Sharpsville, Indiana. Our office and administrative employees transitioned in November 2014. We finalized our move with all production employees and production support moving in December 2015.

2

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NEW & FEATURED

Functional Devices was inducted into the 2022 Manufacturers Hall of Fame by the Indiana Manufacturers Association for recognizing our commitment to the Indiana manufacturing community!

Functional Devices Appoints CEO
Functional Devices was pleased to announce the promotion of Mark Fernandes to Chief Executive Officer in 2022.
Mark Fernandes joined the Company in 2003 as an engineer. During his tenure at the Company, he has held numerous leadership positions, including Engineering Manager and Vice President of Manufacturing and Engineering. In 2014, Mark assumed the role of President and has overseen several strategic initiatives that have increased productivity, shortened time to market for new products, and maintained Functional Devices' reputation as the leader in product quality.

Named One of Best Places to Work in Manufacturing
We were proud to be recognized on the list of 2022 Best Places to Work in Manufacturing, along with 12 other Indiana manufacturers. This
inaugural program was initiated by the Indiana Chamber of Commerce for companies that stand out within the manufacturing industry for creating an outstanding workplace for their employees.

Functional Devices CEO, Mark Fernandes, was appointed to the Continental Automated Buildings Association (CABA) Board of Directors, an international not-for-profit industry association dedicated to the advancement of connected home and intelligent building technologies.

(800) 888-5538 | www.functionaldevices.com

3

NEW & FEATURED

BUILD THE BEST
FOUNDATION
WITH THE RIB® TRIFECTA

4

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NEW & FEATURED

RELAYS

· Prepackaged: LED indicator, pre-wired, transient protection, and optional HOA switch · 10-30 Amp contact ratings · Coil voltages of 10-30 Vac/dc, 24 Vac/dc, 120 Vac, 208-277 Vac, 347 Vac or 480 Vac · Dry contact input relays do not need a transformer and operate on a dry contact closure · Low-input/optoisolated relays require less power from the controller · Mechanically latching and polarized/alarm relays · Red & NEMA 4 housings available

CURRENT SENSORS

· Sense currents as low as 0.125 Amp or as high as 150 Amps · Prepackaged: Sensor, LED indicators, and wires or terminals · Fixed and adjustable models · Relay/current sensor combinations available · Current transducers with 0-5 V, 0-10 V, or 4-20 mA output · Mini current switches as small as 1.5" x 2" · Self-calibrating models available

AC POWER SUPPLIES

· AC power supplies: 40 VA-500 VA · Single and dual transformer models · 500 VA, 300 VA, and 200 VA Class 2 power supplies (Five or three isolated, 24 Vac outputs) · LED indicator with circuit breaker / switch on each transformer available on some models · 120 Vac convenience outlets available, with or without primary 10 Amp circuit breaker · UL508 models available · High/Low voltage separation available · Prepackaged enclosure, power supply, and sub-panel kits

DC POWER SUPPLIES

· 300 mA, 1 Amp, or 2.5 Amp output · Adjustable output available · Class 2 models available

· 120 Vac or 24 Vac input · Isolated and non-isolated · Enclosed or track mount

(800) 888-5538 | www.functionaldevices.com

5

NEW & FEATURED

DIN RAIL RIB® CONTROL RELAYS NO SOCKET NEEDED

Our DIN RIB® No Socket Relays eliminate the need for a pluggable socket, allowing for the unit to be completely enclosed. These no socket models are priced competitively and available, along with DIN rail mounting accessories.

Product Features ·Prepackaged for your convenience ·10 Amp contact rating ·10-30 Vac/dc or 24 Vac/dc coil voltage ·Transient protection ·Models available with override switch ·Current sensor models with adjustable threshold ·UL Listed

Benefits ·Suitable for a wide variety of applications · Compact enclosure allows for smaller footprint on the rail · Relay & current sensor models save space in terminations

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

ADIN35ES Pair of End Stops for 35mm DIN Rail

DIN MOUNT NO SOCKET RELAYS

MODEL # RIBRL1C-NS

COIL VOLTAGE
AC/DC AC
· 10-30

RELAY CONTACTS
1 SPDT

RIBRL1S-NS

· 10-30

1 SPDT

RIBR24D-NS

·

24

1 DPDT

RIBR24SD-NS ·

24

1 DPDT

RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac

CONTACT RATINGS
MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O)

PILOT DUTY 480 VA @ 240/277 Vac 480 VA @ 240/277 Vac
B300 B300

OVERRIDE SWITCH
1 #
1 #

TRACK MOUNT ^ DIN Rail DIN Rail DIN Rail DIN Rail

DIN MOUNT AC SENSORS WITH NO SOCKET RELAYS

MODEL # RIBRXLCF-NS RIBRXLSA-NS

COIL

RELAY OVERRIDE

SENSING

VOLTAGE CONTACTS SWITCH RESISTIVE RANGE

· 10-30 Vac/dc 1 SPST

10 A @ 277 Vac .25-10 A

· 10-30 Vac/dc 1 SPST

1 10 A @ 277 Vac .25-10 A

TYPE * Internal Internal

THRESHOLD Fixed, .25 A Adjustable

SENSOR CONTACT TYPE

SWITCHING MAX. VOLTAGE SWITCHING RANGE CURRENT

Solid State Switch Contact 30 Vac/dc .4 Amps Max

Solid State Switch Contact 30 Vac/dc .4 Amps Max

TRACK MOUNT
^ DIN Rail DIN Rail

= UL Listed - see data sheet for specific Listing # = Coil side relay override (requires unit to be powered) * = Internal current sensor monitors current through common contact of relay ^ = Track mount sold separately

DIN Rail (ADIN35) and pair of end stops (ADIN35ES) sold separately.

FOR MORE PRODUCT INFORMATION, SEE PAGES 32-33 & 101.

6

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NEW & FEATURED

LOW THRESHOLD CURRENT SWITCH FOR ECM APPLICATIONS

Our Low Threshold Current Switch is designed to sense the increasingly low current consumption of ECM units. This ensures that an accurate status feedback of the ECM unit is transmitted back to the controller.

·Low 0.25 Amp adjustable threshold ·Sense loads up to 150 Amps ·Low hysteresis of 10% ·Requires no external power supply ·Normally open (N/O) contact output ·Prepackaged: Terminals,
Two LED indicators ·Can be used in any application with
lower than average current consumption ·Simple installation - only requires a screwdriver ·UL Listed
ECM SENSOR VIEW VIDEO

ECM UNIT

Neutral Line or Load (AC Power)
RIBXGTA-ECM
BAS Controller

Ratcheting clamp tightens around wire

Foot mounting insert included

Slide opening helps with installation in small spaces

FOR MORE PRODUCT INFORMATION, SEE PAGE 88.

(800) 888-5538 | www.functionaldevices.com

7

NEW & FEATURED

NEW! RIB® CURRENT SENSORS

SPLIT OR SOLID CORE CURRENT SWITCHES WITH UP TO 1 AMP SWITCHING CURRENT

Our new Current Switches, with a fixed or adjustable threshold, allow up to 30 Vac/dc output with switching current rated at 1 Amp maximum. These are great for switching larger loads like starters and contactors. The split core model is available with a low sensing range down to 0.125 Amp for monitoring high efficiency motors.

SOLID CORE: RIBXKNUTA ......... PAGE 87

SPLIT CORE: RIBXGNTF-125 ......... PAGE 90

SPLIT CORE TRUE RMS TRANSDUCER WITH SELECTABLE RANGE
Our True RMS Current Transducer can measure the current of waveforms that are not purely sinusoidal. This enables them to be used in applications involving VFDs, phase angle dimmers, switching power supplies and more. A selectable range makes this great for various applications: 10, 20, or 50 Amps.
RIBXGT420-RMS ......... PAGE 94

8

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NEW & FEATURED

PREPACKAGED AC POWER SUPPLIES OFFER EASY & CONVENIENT INSTALLATION
If you're planning to install a controller and other peripheral devices, it is important to consider where the items will be placed within an enclosure and how they will be powered. These kits address those needs to include a Metal Enclosure, Power Supply and Sub-panel with several prepackaged options to meet your specific needs.

Wide Enclosure Single 100 VA Power Supply Perforated Steel Sub-Panel

Narrow Enclosure Single 100 VA Power Supply Perforated Steel Sub-Panel

Narrow Enclosure Dual 100 VA Power Supply
Polymetal Sub-Panel

Power Supply
· Enclosed single or dual 100 VA · 10 Amp on/off circuit breaker switch(es) · 120 Vac convenience outlets · 24 Vac output terminal strip(s) · High/low voltage separation

Enclosure
· Two size choices · Reversible door with key latch · Sturdy 14-Gauge steel
Sub-Panel
· Perforated steel or polymetal · Easily removable for mounting equipment

AC POWER SUPPLY PREPACKAGED KITS

MODEL # CTRL-PS MHP3903100AB10 MHP3903100A100AB10 MHP3904100AB10 MHP3904100A100AB10 MHP4604100AB10 MHP4604100A100AB10

TRANSFORMER(S)
40 VA 100 VA 100 VA, 100 VA 100 VA 100 VA, 100 VA 100 VA 100 VA, 100 VA

INPUT POWER 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac

HEIGHT 14.500 12.500 12.500 12.500 12.500 16.150 16.150

120 VAC AUX OUT- ON/OFF MAIN BREAKER ON WIDTH DEPTH OUTLETS PUT WIRE SWITCH INPUT POWER *

7.700 3.900

·

24.500 6.500 ·

·

· 10 A Switch/Breaker

24.500 6.500 ·

·

· 10 A Switch/Breaker

24.500 6.500 ·

·

· 10 A Switch/Breaker

24.500 6.500 ·

·

· 10 A Switch/Breaker

20.000 6.720 ·

·

· 10 A Switch/Breaker

20.000 6.720 ·

·

· 10 A Switch/Breaker

SECONDARY

METAL

CONFIGURATION HOUSING

MH1000

SUB-PANEL / TRACK MOUNT
MT212-4 included

Ext. Terminal Strip MH3900 SP3803S (Polymetal)

Ext. Terminal Strip MH3900 SP3803S (Polymetal)

Ext. Terminal Strip MH3900 SP3804S (Perforated)

Ext. Terminal Strip MH3900 SP3804S (Perforated)

Ext. Terminal Strip MH4600 SP4604 (Perforated)

Ext. Terminal Strip MH4600 SP4604 (Perforated)

* = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A

FOR MORE PRODUCT INFORMATION, SEE PAGES 120-122.

(800) 888-5538 | www.functionaldevices.com

9

NEW & FEATURED

AC POWER SUPPLIES
WITH LOW VOLTAGE COMPARTMENT

Eliminate high voltage in your control panel and the need for personal protective equipment (PPE) by using our Low Voltage Compartment Power Supplies. This series of products has a separate wiring compartment (with removable cover) to safely access the removable terminal blocks.

Multi-tap Primary
480/277/240/120 Vac OR 480/347/277/240/120 Vac

Perfect for providing Class 2 low voltage to central power supply
panels and peripheral devices

480 277 240 120 COM
ON 1
OFF
ON OFF 2
ON OFF 3
ON OFF 4
ON OFF 5

Low Voltage Compartment for safe access

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC

PSH30C0onAtr-oLlleVr C P24SVHac500A-LVC

TCP-1

TCP-2

TCP-3

TCP-4

TCP-5

Features
· Three or five isolated 100 VA Class 2, 24 Vac outputs with 4 Amp Breaker and individual On/Off switches. Also available with five 40 VA outputs (See chart below)
· NEMA 1 metal enclosure has separate low voltage compartment with cover · Multi-tap primaries: 480/277/240/120 Vac or 480/347/277/240/120 Vac · Seismic Certification of Equipment and Components: OSP-0201-10 · UL Listed

AC POWER SUPPLIES WITH LOW VOLTAGE COMPARTMENT

MODEL # PSH500A-LVC

TRANSFORMER(S)
· 500 VA (five 100 VA Outputs)

INPUT POWER
480/277/240/120 Vac

HEIGHT
12.125

WIDTH
12.125

DEPTH
6.000

120 VAC BREAKER PER SECONDARY OUTLET# OUTPUT CONFIGURATION

5 x 4 Amp

Terminals

PSH300A-LVC · 300 VA (three 100 VA Outputs)

480/277/240/120 Vac

12.125 12.125 6.000

3 x 4 Amp

Terminals

PSH200A-LVC · 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac 12.125 12.125 6.000

5 x 2 Amp

Terminals

PSH500AB10-LVC · 500 VA (five 100 VA Outputs)

120 Vac

12.125 12.125 6.000

·

5 x 4 Amp

Terminals

PSH300AB10-LVC · 300 VA (three 100 VA Outputs)

120 Vac

12.125 12.125 6.000

·

3 x 4 Amp

Terminals

PSH200AB10-LVC · 200 VA (five 40 VA Outputs)

120 Vac

12.125 12.125 6.000

·

5 x 2 Amp

Terminals

= Class 2 UL Listed - see data sheet for specific Listing

# = Convenience outlet has 4 Amp Breaker

HOUSING STYLE
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment
Enclosed with Low Voltage Compartment

FOR MORE PRODUCT INFORMATION, SEE PAGE 115-119.

10

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NEW & FEATURED

RIB® DC POWER SUPPLIES
WITH SINGLE OR DUAL 100 VA TRANSFORMERS

· Output Power: 24 Vdc @ 2.5 Amp
· Isolation, circuit breaker, status LED,  ON/OFF switch, convenience outlets

· Class 2 DC Power Supply · Input Power: 120 Vac

FOR MORE PRODUCT INFORMATION, SEE PAGE 126.

DIN RAIL MOUNT DC POWER SUPPLIES

DIN MOUNT DC POWER SUPPLIES

MODEL # PULS-ML15-241 PULS-PIC120-241D PULS-PIC240-241D PULS-PIM36-241 PULS-PIM60-241 PULS-PIM60-245 PULS-PIM90-241 PULS-PIM90-245 PULS-PIM90-245-L1

VOLTAGE INPUT

·

100-240 Vac

· 100-120Vac; 200-240Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

VOLTAGE OUTPUT Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated

OUTPUT CURRENT
600 mA 5 Amp 10 Amp 1.5 Amp 2.5 Amp 2.5 Amp 3.8 Amp 3.8 Amp 3.8 Amp

ON/OFF SWITCH

HEIGHT 2.950 4.880 4.880 3.540" 3.540" 3.540" 3.540" 3.540" 3.540"

WIDTH 0.890 1.540 1.930" 0.860" 1.420" 1.420" 1.420" 1.420" 1.420"

DEPTH 3.580 4.880 4.880 3.580" 3.580" 3.580" 3.580" 3.580" 3.580"

HOUSING STYLE / TRACK MOUNT
DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount

= Class 2 UL Listed - see data sheet for specific Listing

* = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A

FOR MORE PRODUCT INFORMATION, SEE WEBSITE.

(800) 888-5538 | www.functionaldevices.com

11

NEW & FEATURED

COMPATIBLE FAN SAFETY ALARM CIRCUIT & GENERAL PURPOSE LOGIC BOARD

Our BACnet® Compatible Fan Safety Alarm Circuit & General Purpose Logic Board combines all the relay logic to facilitate fan status, fan safety control, and damper actuator control. It is intended for use in a circuit that will control fan start/stop and fan safety shut-down circuit monitors critical inputs:

· Low-limit freeze protection · Static pressure (to monitor for

(to stop fan and remove power high/low pressure condition)

from damper actuator)

· Smoke detector/fire alarm

Fan Safety Mode (Factory Default) · 6 BI's for Safety Devices · 1 BI for Fan Status · 1 BO for Fan Shutdown (Safeties) · 1 BO for Fan Start · 24Vac/dc · 3 Amp Field Device Power (Actuator) · Local/Remote Reset · Latch/Unlatch DIP Switch Selectable
Benefits · UL864 Safety Device · Approved California State Fire Marshal · Reduces Controller I/O · Saves Field Installation Cost · Standardized Safety Design · Local/Remote Alarm Identification · Local/Remote Reset · Stand Alone Operation
General Purpose Mode
· 7 BI's · 2 BO's with override: 1 SPDT 10A Relay;
1 SPDT 20A Ballast Rated Relay)

RIBTWLB-7-BC NEMA 1 Housing
Shown without cover

RIBMNWLB-7-BC Track Mount

Fan Safety Application

BACnet® MS/TP

BO 1-1

BO 1-2

BI 1-6

BO-2 BI 1-7

24 Vac/dc Field Devices To Motor Starter To Motor Starter

N.C. or N.O. Safety Devices
(Up to 6)

Motor Status

Air Handling Unit Fan Safety Shutdown
VIEW VIDEO

L1

Typical Starter Wiring

L2

H

M

O

BO 1-2

A BO 2

FOR MORE PRODUCT INFORMATION, SEE PAGE 134.

12

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NEW & FEATURED

PREPACKAGED

DEVICES

MAKE THE JOB EASY

Use these products to save I/O space on costly DDC controllers.

RIBTWX2402B-BC

RIBTW2401B-BC

RIBMNW24B-BCAI PSH600-UPS-BC

Features
 · MS/TP network  · One binary output (20 Amp)  · One binary input (dry contact)  · Field addressable  · DIP switch selectable baud rate  · Power inputs: 24 Vac/dc or 120 / 208-277 Vac  · Enclosed or track mount models  · UL Listed  · BTL Certified

Several Devices with Varying Options
 · Relays  · Relay & current sensor combinations  · Expansion module  · Analog input  · Analog output  · Thermistor input  · Accumulator input  · 600 VA UPS power supply kit  · Fan safety alarm circuit/general purpose logic board

FOR MORE PRODUCT INFORMATION, SEE PAGE 142-155.

(800) 888-5538 | www.functionaldevices.com

13

NEW & FEATURED

COMPATIBLE DEVICES APPLICATIONS

Mounting your controller and peripheral devices is easy and convenient in our prepackaged solution..
See the diagrams below for examples of common uses.

RIBTW2401B-BC, RIBTW2402B-BC

MS/TP

DO

Pump or Fan Start/Stop

DI

Status

RIBMNWX2401B-BC, RIBTWX2401B-BC, RIBMNWX2402B-BC, RIBTWX2402B-BC

MS/TP

DO

Pump or Fan Start/Stop

DI

Status, Flow Switch

Internal Current Sensor

RIBMNW24B-BCAI, RIBTW24B-BCAI

MS/TP

DO DI (2) AI

Exhaust Fan Start/Stop Status Room Temperature

RIBTW24B-BCAO

DO

MS/TP

DI

AI

AO

RIBMNWD12-BCDI

Pump or Fan Start/Stop Status, Flow Switch Water Temperature Valve Position

MS/TP RIBMNWD12-BC MS/TP RIBMW24B-44-BC MS/TP

DI (12)
DI (10) ACM (2)
DO (4) DI (4)

Fan Wall Status or Kitchen Hood Status
Pump Status Pulse Meter
Pump or Fan Start/Stop Status

14

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NEW & FEATURED

Local Logic

Network Devices

with Set Point Function for binary output

Designed for remote/local applications: Cabinet unit heater, cooler/freezer, exhaust fan, fluid level - sump pump, building pressure, etc.

Features
 · BACnet® MS/TP network  · One binary output: 20 Amp
SPDT + override  · Two binary inputs: Dry contact  · One analog input: Thermistor T2
or T3, 0-5Vdc, 0-10Vdc · 24 Vac/dc power  · NEMA 1 enclosure, available in
NEMA 4 enclosure  · UL Listed
BACnet MS/TP

RIBMNW24B-BCAI 6" Mounting Track Included

Set Point Differential

Logic

BI 1

Dry Contact Input 1

BI 2

Dry Contact Input 2

AI 1

Analog Input

0-5Vdc, 0-10Vdc

T2/T3 Thermistor

BO 1

SPDT 20 Amp Relay

With Override

RIBTW24B-BCAI NEMA 1 Housing

Exhaust Fan
Temperature
AHU

Transformer

BCAI

Fluid Level - Sump Pump

Transformer

BCAI

Building Pressure

Building Pressure

Damper

Hi

Low

AHU

Transformer

BCAI

Cabinet Unit Heater

Cooler/Freezer
Temperature

Transformer

BCAI

Walkin Freezer/Cooler
Door Switch

Audible alarm or alarm lamp
FOR MORE PRODUCT INFORMATION, SEE PAGES 150-151.

(800) 888-5538 | www.functionaldevices.com

15

NEW & FEATURED

POWER METER KIT
Introducing our new BACnet® Compatible Power Meter Kit. This Power Meter Kit includes the BACnet® Compatible Power Meter circuit board, which will collect and send all the data points to the BAS controller. Also included in this Kit is the fuse holder, fuses, and disconnect switch. Everything is prepackaged and prewired in an 18-gauge steel enclosure. This Power Meter Kit is compatible with single or three-phase electrical systems. This Kit is a great solution for revenue-grade power metering applications.

· Revenue Grade Power Meter · Power Meter input power: 120-277 Vac · Made in the U.S.A

· Includes 16 Amp rated Disconnect Switch * · Includes Fuse holder with three 2 Amp rated fuses ^
Dimensions: 8.3" H x 7.7" W (9.2" W with switch) x 3.9" D

BACnet Power Meter Kit
· Power meter circuit board · Disconnect switch · Fuse holder · Fuses
RIBPM413-BC-KIT

A B C N
A B C

REF

NOT USED

B(+)

REMOTE STATUS

NOT USED

LED

LED

A(-)

*
^

#

LINE 1

CT L3

LINE 2

CT L2

LINE 3

CT L1

NEUTRAL

Current Transformers
See page 163 for available models

FOR MORE PRODUCT INFORMATION, SEE PAGE 160.

16

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NEW & FEATURED

RIB® CURRENT TRANSFORMERS

CT-05A0-333

CT-100A2-333

CT-400A4-333

ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV

CT-100A1-333

CT-100A4-333

CT-200A4-333

CT-025A1-333

CT-050A1-333

CTS-100A55-333

MOD1-07-33MV

FDI MODEL
CT-05A0-333 CT-025A1-333 CT-050A1-333 CT-100A1-333 CT-100A2-333 CT-100A4-333 CT-200A4-333 CT-400A4-333 CT-600A4-333 CTS-05A20-333 CTS-30A20-333 CTS-60A35-333 CTS-100A55-333 ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV

PRIMARY INPUT (A) SECONDARY OUTPUT (V)

RATIO

5 25 50 100 100 100 200 400 600 5 30 60 100 4,000 6,000 8,000 10,000

0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.07 0.07 0.07 0.07

5A/0.333V 25A/0.333V 50A/0.333V 100A/0.333V 100A/0.333V 100A/0.333V 200A/0.333V 400A/0.333V 600A/0.333V 5A/0.333V 30A/0.333V 60A/0.333V 100A/0.333V 4,000/70mV 6,000/70mV 8,000/70mV 10,000/70mV

ACCURACY (%) 0.3 0.8 0.5 0.5 0.75 0.5 0.5 0.5 0.5 0.2 0.2 0.2 0.2 0.75 0.75 0.75 0.75

CORE TYPE
Split Split Split Split Split Split Split Split Split Solid Solid Solid Solid Rope Rope Rope Rope

WINDOW SIZE
.47" x .45" .72" x .62" .72" x .62" .72" x .62" 1.0" x 1.4" 1.3" x 1.7" 1.3" x 1.7" 1.3" x 1.7" 1.3" x 1.7" .2" diameter .2" diameter .35 diameter .55 diameter 5.0" diameter 7.6" diameter 11.5" diameter 15.3" diameter

"MOD" & "ROPE" Series
The MOD series of devices are optional modules that connect to the output of the Rogowski Coil CTs (ROPE units) and convert the output to the 0.333 V analog scale for use in other Power Monitoring systems. The MOD series has options for one, two, or three-phase power feeds. The MOD series devices are DIN rail-mountable, are ETL approved, and require 12 Vdc for input voltage.

FDI MODEL
MOD1-07-33MV MOD2-07-33MV MOD3-07-33MV ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV

PRIINPUT (A)
0.07 0.07 0.07 4,000 6,000 8,000 10,000

SECONDARY OUTPUT (V)
0.333 0.333 0.333 0.07 0.07 0.07 0.07

ACCURACY (%)
0.50 0.50 0.50 0.75 0.75 0.75 0.75

USED WITH
Any "ROPE" CT Any "ROPE" CT Any "ROPE" CT Any "MOD" CT Any "MOD" CT Any "MOD" CT Any "MOD" CT

FOR MORE PRODUCT INFORMATION, SEE WEBSITE.

(800) 888-5538 | www.functionaldevices.com

17

NEW & FEATURED

NOTES

18

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

PILOT RELAYS: 10­15 AMPS

RELAYS

RIBT2401D

RIBH1S

RIBU1C-N4

RIBMU1SC

RIBRL1C-NS

ENCLOSED PILOT RELAYS

MODEL # RIBU1C RIBH1C RIBU2C RIBH2C RIBL3C RIBL4C RIBU1S RIBH1S RIBU1SM-250 RIBH1SM-250 RIB2401D RIB2402D RIBU1SC RIBH1SC RIBL1C-DC RIB2421C RIB2401C
RIBD2421C ~ RIBU2SC RIBU2S2

COIL VOLTAGE

AC/DC
· 10-30

RELAY AC CONTACTS

120

1 SPDT

·

10-30 208-277

1 SPDT

· 10-30

120

2 SPDT

·

10-30 208-277

2 SPDT

· 10-30

3 SPST

· 10-30

3 SPST, 1 SPDT

· 10-30

120

1 SPST

·

10-30 208-277

1 SPST

· 10-30

120

1 SPST

·

10-30 208-277

1 SPST

·

24

120

1 DPDT

·

24

208-277 1 DPDT

· 10-30

120

1 SPDT

·

10-30 208-277

1 SPDT

· 10-30 Vdc only

1 SPDT

·

24

120-277 1 SPDT

·

24

120

1 SPDT

·

24

120-277 1 SPDT

· 10-30

120 1 SPST, 1 SPDT

· 10-30

120

2 SPST

RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 120/250 Vac 10 A @ 120/250 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac

CONTACT RATINGS
MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120/240 Vac (N/O) 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O)
1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O)

PILOT DUTY 480 VA @ 240-277 Vac

HIGH/LOW OVERRIDE HOUSING SEPARATION SWITCH STYLE *
A

SPEC PAGE
22

480 VA @ 240-277 Vac

A

22

480 VA @ 240-277 Vac

B

22

480 VA @ 240-277 Vac

480 VA @ 240-277 Vac

·

480 VA @ 240-277 Vac

·

B

22

C

23

C

23

480 VA @ 277 Vac

1

B

23

480 VA @ 277 Vac

1

B

23

345 VA @ 120/240 Vac

1+monitor

B

24

345 VA @ 120/240 Vac

1+monitor

B

24

B300

A

24

B300 480 VA @ 277 Vac 480 VA @ 277 Vac

A

24

2 +

B

25

2 +

B

25

480 VA @ 240-277 Vac

A

25

C300

A

26

770 VA @ 250 Vac

C300

·

A

26

C

27

480 VA @ 277 Vac

480 VA @ 277 Vac

·

1

B

28

2

C

28

= UL Listed - see data sheet for specific Listing + = SPDT with override requires 2 switches

* = See Housing Guide on page 201 ^ = Track mount sold separately

# = Coil side relay override (requires unit to be powered) ~ = Time Delay

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

19

RELAYS

PILOT RELAYS: 10­15 AMPS

Convenient Prepackaging is a Great Time Saver

· LED indicator · Multiple contact ratings · Override / HOA switch options available · High/low voltage separation available

· 10-15 Amp models · Pre-wired · Enclosed or track mount · Time delay models

T STYLE PILOT RELAYS

MODEL # RIBTU1C

COIL VOLTAGE

RELAY

AC/DC AC CONTACTS

· 10-30 120

1 SPDT

RIBTH1C

· 10-30 208-277 1 SPDT

RIBTU2C

· 10-30 120

2 SPDT

RIBTH2C

· 10-30 208-277 2 SPDT

RIBU1CW

· 10-30 120

1 SPDT

RIBH1CW

· 10-30 208-277 1 SPDT

RIBTU1S

· 10-30 120

1 SPST

RIBTH1S

· 10-30 208-277 1 SPST

RIBTU1SC

· 10-30 120

1 SPDT

RIBTH1SC

· 10-30 208-277 1 SPDT

RIBT2401D

·

24

120

1 DPDT

RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 15 A @ 150 Vac 15 A @ 150 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac

CONTACT RATINGS

MOTOR

PILOT DUTY

HIGH/LOW OVERRIDE HOUSING SPEC SEPARATION SWITCH STYLE * PAGE

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac

·

C

29

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac

·

C

29

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac

·

C

29

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac

·

C

29

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac

·

C

30

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac

·

C

30

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac

·

1

C

30

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac

·

1

C

30

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac

·

2 +

C

31

1/3 HP @ 120-240 Vac (N/O) 480 VA @ 277 Vac

·

2 +

C

31

1/2 HP @ 120-240 Vac (N/O)

B300

·

C

31

DIN MOUNT PILOT RELAYS

MODEL # RIBRL1C-NS

COIL VOLTAGE

AC/DC

RELAY AC CONTACTS

· 10-30

1 SPDT

RIBRL1S-NS

· 10-30

1 SPDT

RIBR24D-NS

· 24

1 DPDT

RIBR24SD-NS · 24

1 DPDT

RIBRL1C

· 10-30

1 SPDT

RIBRL1S

· 10-30

1 SPDT

RIBR24D

· 24

1 DPDT

RIBR24SD

· 24

1 DPDT

RESISTIVE 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac

CONTACT RATINGS
MOTOR 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O) 1/2 HP @ 120-240 Vac (N/O)

PILOT DUTY 480 VA @ 240/277 Vac 480 VA @ 240/277 Vac
B300 B300 480 VA @ 240/277 Vac 480 VA @ 240/277 Vac B300 B300

OVERRIDE SWITCH
1 #
1 #
1 #
1 #

NO SOCKET
·
·
·
·

TRACK SPEC MOUNT ^ PAGE

DIN Rail

32

DIN Rail

32

DIN Rail

33

DIN Rail

33

DIN Rail

34

DIN Rail

34

DIN Rail

35

DIN Rail

35

= UL Listed - see data sheet for specific Listing + = SPDT with override requires 2 switches

* = See Housing Guide on page 201 ^ = Track mount sold separately

# = Coil side relay override (requires unit to be powered)

20

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

PPIILLOOTTRREELLAAYYSS::1100­­1155AAMMPPSS

TRACK MOUNT PILOT RELAYS

MODEL #

COIL VOLTAGE AC/DC AC

RELAY CONTACTS

RIBAN12C

· 2 12

1 SPDT

RESISTIVE 10 A @ 277 Vac

RIBAN24C

· 2 24

RIBM12C

· 12

RIBM12S

· 12

RIBM24C

· 24

RIBM24S

· 24

RIBM2401D

· 24

RIBM2402D

· 24

RIBMU1C

· 10-30

RIBMH1C

· 10-30

RIBMU1S

· 10-30

RIBMH1S

· 10-30

RIBMU2C

· 10-30

RIBMH2C

· 10-30

RIBMU1SM-250 · 10-30

RIBMH1SM-250 · 10-30

RIBMU1SC

· 10-30

RIBMH1SC

· 10-30

RIBMN12C

· 12

RIBMN12S

· 12

RIBMN24C

· 24

RIBMN24S

· 24

RIBMN24S-J

· 24

RIBMN24C-4T

·

24

RIBMN24S-4T

·

24

RIBMN2401D

· 24

RIBMNU1C

· 10-30

RIBMNH1C

· 10-30

RIBMNU1S

· 10-30

RIBMNH1S

· 10-30

RIBMNU1SM-250 · 10-30

RIBMNH1SM-250 · 10-30

120 208-277
120 208-277
120 208-277
120 208-277
120 208-277
120 208-277
120 120 208-277 120 208-277 120 208-277

1 SPDT
1 SPDT 1 SPST 1 SPDT 1 SPST 1 DPDT 1 DPDT 1 SPDT 1 SPDT 1 SPST 1 SPST 2 SPDT 2 SPDT 1 SPST 1 SPST 1 SPDT 1 SPDT 1 SPDT 1 SPST 1 SPDT 1 SPST 1 SPST 4 SPDT 4 SPST 1 DPDT 1 SPDT 1 SPDT 1 SPST 1 SPST 1 SPST 1 SPST

10 A @ 277 Vac
15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 10 A @ 277 Vac 10 A @ 277 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 15 A @ 125 Vac 10 A @ 277 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 150 Vac 15 A @ 125 Vac 15 A @ 125 Vac

CONTACT RATINGS MOTOR 1 HP @ 250 Vac 1 HP @ 250 Vac 1 HP @ 250 Vac

PILOT DUTY C300
C300 C300

OVERRIDE TRACK

SPEC

SWITCH

MOUNT ^ PAGE

MT212 Series & DIN Rail

36

MT212 Series & DIN Rail

36

MT4 Series

37

1 HP @ 250 Vac

C300

1

MT4 Series

37

1 HP @ 250 Vac

C300

MT4 Series

37

1 HP @ 250 Vac

C300

1

MT4 Series

37

1/2 HP @ 120/240 Vac (N/O)

B300

MT4 Series

38

1/2 HP @ 120/240 Vac (N/O)

B300

MT4 Series

38

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 240-277 Vac

MT4 Series

38

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 240-277 Vac

MT4 Series

38

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 277 Vac

1

MT4 Series

39

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 277 Vac

1

MT4 Series

39

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 240-277 Vac

MT4 Series

39

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 240-277 Vac

MT4 Series

39

1/3 HP @ 120-240 Vac (N/O) 345 VA @ 120/240 Vac (N/O) 1+monitor MT4 Series

40

1/3 HP @ 120-240 Vac (N/O) 345 VA @ 120/240 Vac (N/O) 1+monitor MT4 Series

40

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 277 Vac

2 +

MT4 Series

40

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 277 Vac

2 +

MT4 Series

40

1 HP @ 250 Vac

C300

MT212 Series

41

1 HP @ 250 Vac

C300

1

MT212 Series

41

1 HP @ 250 Vac

C300

MT212 Series

41

1 HP @ 250 Vac

C300

1

MT212 Series

41

1 HP @ 250 Vac

C300

1

MT212 Series

42

1 HP @ 250 Vac

C300

MT212-6 Included 42

1 HP @ 250 Vac

C300

4

MT212-6 Included 42

1/2 HP @ 120/240 Vac (N/O)

B300

MT212 Series

43

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 240-277 Vac

MT212 Series

43

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 240-277 Vac

MT212 Series

43

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 277 Vac

1

MT212 Series

44

1/3 HP @ 120-240 Vac (N/O)

480 VA @ 277 Vac

1

MT212 Series

44

1/3 HP @ 120-240 Vac (N/O) 345 VA @ 120/240 Vac (N/O) 1+monitor MT212 Series

44

1/3 HP @ 120-240 Vac (N/O) 345 VA @ 120/240 Vac (N/O) 1+monitor MT212 Series

44

= UL Listed - see data sheet for specific Listing + = SPDT with override requires 2 switches

* = See Housing Guide on page 201 ^ = Track mount sold separately

# = Coil side relay override (requires unit to be powered)

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

21

RELAYS

10 AMP PILOT CONTROL RELAYS

RIBU1C
Pilot Relay, 10 Amp SPDT, 10-30 Vac/dc/
120 Vac Coil, NEMA 1 Housing

RIBH1C
Pilot Relay, 10 Amp SPDT, 10-30 Vac/dc/
208-277 Vac Coil, NEMA 1 Housing

Wht/Blk

Blu

120 Vac

N/C

Wht/Brn

Blu

208-277 Vac

N/C

Wht/Blu

Yel

10-30 Vac/dc

C

Wht/Blu

Yel

10-30 Vac/dc

C

Wht/Yel

Org

Comm

N/O

Wht/Yel

Org

Comm

N/O

RIBU1C-RD RIBH1C-RD · Red housing

RIBU1C-N4 RIBH1C-N4 · NEMA 4X
housing

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, C-UL, CE, RoHS (All models) UL916 (RIBU1C, RIBH1C) UL864, California State Fire Marshal (RIBU1C-RD, RIBH1C-RD) UL508 (RIBU1C-N4, RIBH1C-N4) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac (RIBU1C) 39 mA @ 208-277 Vac (RIBH1C)

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc
Note: Order packs by adding "-5PACK", "-10PACK", "-25PACK", or "-100PACK" to end of model number.

10 AMP PILOT CONTROL RELAYS

RIBU2C
Pilot Relays, 10 Amp 2 SPDT, 10-30 Vac/dc/
120 Vac Coil, NEMA 1 Housing

RIBH2C
Pilot Relays, 10 Amp 2 SPDT, 10-30 Vac/dc/
208-277 Vac Coil, NEMA 1 Housing

Wht/Blk 120 Vac

Blu

Wht/Brn

Blu

N/C

208-277 Vac

N/C

Wht/Blu

Yel

Wht/Blu

Yel

10-30 Vac/dc

C

10-30 Vac/dc

C

Wht/Yel

Org

Wht/Yel

Org

Comm

N/O

Comm

N/O

Wht/Red 120 Vac

Gry

Wht/Org

Gry

N/C

208-277 Vac

N/C

Gry/Wht

Prp

Gry/Wht

Prp

10-30 Vac/dc

C

10-30 Vac/dc

C

Wht/Prp

Brn

Wht/Prp

Brn

Comm

N/O

Comm

N/O

SPECIFICATIONS
# Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.75" NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU2C) 39 mA @ 208-277 Vac (RIBH2C)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

22

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

10 AMP PILOT CONTROL RELAYS

RIBL3C
Pilot Relays, 10 Amp 3 SPST-N/O,
10-30 Vac/dc Coil, NEMA 1 Housing

RIBL4C
Pilot Relays, 10 Amp 3 SPST-N/O + 1 SPDT,
10-30 Vac/dc Coil, NEMA 1 Housing

Wht/Blk RELAY 1

Blk
RELAY 1 Blk

Wht/Blu RELAY 2

Blu
RELAY 2 Blu

Wht/Yel RELAY 3

Yel
RELAY 3 Yel

Wht/Red Comm

· All relay coils use the same common · All relay coils 10-30 Vac/dc

Wht/Blk RELAY 1
Wht/Blu RELAY 2
Wht/Yel RELAY 3
Wht/Brn RELAY 4
Wht/Red Comm · All relay coils use the same common · All relay coils 10-30 Vac/dc

Blk RELAY 1
Blk Blu RELAY 2 Blu Yel RELAY 3 Yel Gry RELAY 4 Prp
Brn

SPECIFICATIONS
# Relays & Contact Type: Three (3) SPST Continuous Duty Coil (RIBL3C) Three (3) SPST + One (1) SPDT Continuous Duty Coil (RIBL4C)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple
Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes
Override Switch: No

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

10 AMP PILOT CONTROL RELAYS

RIBU1S
Pilot Relay, 10 Amp SPST-N/O + Override,
10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing

RIBH1S
Pilot Relay, 10 Amp SPST-N/O + Override,
10-30 Vac/dc/208-277 Vac Coil, NEMA 1 Housing

Wht/Blk 120 Vac
Wht/Blu 10-30 Vac/dc

CLOSED OPEN AUTO

Wht/Brn 208-277 Vac
Wht/Blu 10-30 Vac/dc

CLOSED OPEN AUTO

Wht/Yel Comm

Org

Wht/Yel Comm

Org

Org

Org

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes

Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)
Notes: Order Normally Closed by adding "-NC" to end of model number

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Notes: Order Normally Closed by adding "-NC"
to end of model number

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1S) 39 mA @ 208-277 Vac (RIBH1S)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

23

RELAYS

10 AMP PILOT CONTROL RELAYS

RIBU1SM-250
Pilot Relay, 10 Amp SPST-N/O + Override + Monitor, 10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing

RIBH1SM-250
Pilot Relay, 10 Amp SPST-N/O + Override + Monitor, 10-30 Vac/dc/208-277 Vac Coil, NEMA 1 Housing

Wht/Blk 120 Vac
Wht/Blu 10-30 Vac/dc
Wht/Yel Comm
CLOSED OPEN AUTO

CLOSED OPEN AUTO

Wht/Brn 208-277 Vac
Wht/Blu 10-30 Vac/dc
Wht/Yel Comm
CLOSED OPEN AUTO

CLOSED OPEN AUTO

AUTO C
CLOSED
AUTO C
CLOSED

Brn Prp Gry POLE 2

Org

Org

POLE 1

Brn Prp Gry POLE 2

Org

Org

POLE 1

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes + Monitor

Contact Ratings: 10 Amp Resistive @ 120/250 Vac 345 VA Pilot Duty @ 120/240 Vac 211 VA Pilot Duty @ 120/240 Vac 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C)
Coil Current: 55 mA @ 30 Vac 28 mA @ 120 Vac (RIBU1SM-250) 39 mA @ 208-277 Vac (RIBH1SM-250) 20 mA @ 30 Vdc

Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc
Notes: · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 250 Vac max and 5 Amp max · Order Normally Closed by adding "-NC" to end of model number

10 AMP PILOT CONTROL RELAYS

RIB2401D
Pilot Relay, 10 Amp DPDT, 24 Vac/dc/
120 Vac Coil, NEMA 1 Housing

RIB2402D
Pilot Relay, 10 Amp DPDT, 24 Vac/dc/
208-277 Vac Coil, NEMA 1 Housing

Wht/Blk 120 Vac
Wht/Blu 24 Vac/dc
Wht/Yel Comm

Blu

Blu

N/C

Wht/Brn

N/C

Yel

208-277 Vac

Yel

C

C

Org

Org

N/O

N/O

Wht/Blu

24 Vac/dc

Gry

Gry

N/C

N/C

Prp

Prp

C

Wht/Yel

C

Brn

Comm

Brn

N/O

N/O

RIB2401D-RD RIB2402D-RD · Red housing

RIB2401D-N4 RIB2402D-N4 · NEMA 4X
housing

SPECIFICATIONS

# Relays & Contact Type: One (1) DPDT Continuous Duty Coil

Contact Ratings:

Expected Relay Life: 10 million cycles minimum mechanical

10 Amp Resistive @ 30 Vdc

Operating Temperature: -30 to 140° F

10 Amp General Use @ 277 Vac

Humidity Range: 5 to 95% (noncondensing)

1/2 HP @ 120/240 Vac (N/O)

Operate Time: 8ms

1/3 HP @ 120/240 Vac (N/C)

Relay Status: LED On = Activated

B300 Pilot Duty

Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple

120 Vac 30A Make 3A Break (360 VA)

Housing Detail: See Housing A in housing guide for dimensions

240 Vac 15 A Make 1.5A Break (360 VA)

Origin: Made of US and non-US parts

208 Vac 17.3A Make 1.73A Break (360 VA)

Wires: 16, 600V Rated

277 Vac 13A Make 1.3A Break (360 VA)

Approvals: UL Listed, C-UL, CE, RoHS (All models)

24 Vac 30A Make 5A Break (120VA) 5A Max

UL916 (RIB2401D, RIB2401D-RD, RIB2402D, RIB2402D-RD)

UL864, California State Fire Marshal (RIB2401D-RD, RIB2402D-RD)

UL508 (RIB2401D-N4, RIB2402D-N4)

Housing Rating: UL Accepted for Use in Plenum, NEMA 1

Gold Flash: No

Override Switch: No

Coil Current:

24 mA @ 18 Vac

20 mA @ 20 Vdc

32 mA @ 24 Vac

24 mA @ 24 Vdc

40 mA @ 30 Vac

36 mA @ 30 Vdc

31 mA @ 120 Vac (RIB2401D)

36 mA @ 208-277 Vac (RIB2402D)

Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401D) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402D) Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc

24

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

10 AMP PILOT CONTROL RELAYS

RIBU1SC
Pilot Relay, 10 Amp SPDT + Override,
10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing

RIBH1SC
Pilot Relay, 10 Amp SPDT + Override,
10-30 Vac/dc/208-277 Vac Coil, NEMA 1 Housing

Wht/Blk 120 Vac

Wht/Blu 10-30 Vac/dc

Yel C

MANUAL

Wht/Yel Comm

AUTO

Blu N/C

Org

OPEN

N/O

N/C N/O CLOSED CLOSED

Wht/Brn 208-277 Vac

Wht/Blu 10-30 Vac/dc

Yel C

MANUAL

Wht/Yel Comm

AUTO

Blu N/C

Org

OPEN

N/O

N/C N/O CLOSED CLOSED

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2)
10 AMP PILOT CONTROL RELAYS
RIBL1C-DC
Pilot Relay, 10 Amp SPDT, 10-30 Vdc Limited Inrush Coil, NEMA 1 Housing

Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1SC) 39 mA @ 208-277 Vac (RIBH1SC)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Wht/Blu

Blu

10-30 Vdc

N/C

Yel C

Wht/Yel

Org

Comm

N/O

RIBL1C-DC-RD · Red housing

RIBL1C-DC-N4 · NEMA 4X housing

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, C-UL, CE, RoHS (All models) UL916 (RIBL1C-DC) UL864, California State Fire Marshal (RIBL1C-DC-RD) UL508 (RIBL1C-DC-N4) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast

600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Coil Voltage Input: 10-30 Vdc Drop Out = 2.8 Vdc Pull In = 10 Vdc

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

25

RELAYS

10 AMP PILOT CONTROL RELAYS
RIB2421C
Pilot Relay, 10 Amp SPDT, 24 Vac/dc/ 120-277 Vac Coil, NEMA 1 Housing

Wht/Brn 120-277 Vac
Wht/Blu 24 Vac/dc
Wht/Yel Comm

Blu
N/C
GREAT SERVICE

Yel

TRUCK RELAY

C

ONE RELAY COVERS

MOST APPLICATIONS
Org N/O

RIB2421C-RD · Red housing

RIB2421C-N4 · NEMA 4X housing

SPECIFICATIONS

# Relays & Contact Type: One (1) SPDT Continuous Duty Coil

Contact Ratings:

Expected Relay Life: 10 million cycles minimum mechanical

10 Amp General Use @ 277 Vac

Operating Temperature: -30 to 140° F

10 Amp Resistive @ 30 Vdc (N/O)

Humidity Range: 5 to 95% (noncondensing)

7 Amp Resistive @ 30 Vdc (N/C)

Operate Time: 20ms

1/2 HP @ 125 Vac

Relay Status: LED On = Activated

1 HP @ 250 Vac

Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple

1/4 HP @ 277 Vac

Housing Detail: See Housing A in housing guide for dimensions C300 Pilot Duty

Origin: Made of US and non-US parts

Wires: 16, 600V Rated

Approvals: UL Listed, C-UL, CE, RoHS (All models)

UL916 (RIB2421C)

UL864, California State Fire Marshal (RIB2421C-RD)

UL508 (RIB2421C-N4)

Housing Rating: UL Accepted for Use in Plenum, NEMA 1

Gold Flash: No

Override Switch: No

10 AMP TRIVOLT CONTROL RELAYS
RIB2401C
TriVolt Relay, 10 Amp SPDT, 24Vac/dc or 120Vac, NEMA 1 Housing

Coil Current: 66 mA @ 24 Vac 38 mA @ 24 Vdc 40 mA @ 120-277 Vac

Coil Voltage Input: 24 Vac/dc ; 120-277 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

Wht/Blk

Blu

120 Vac

N/C

Wht/Blu

Yel

24 Vac/dc

C

Wht/Yel

Org

Comm

N/O

RIB2401C-RD · Red housing

RIB2401C-N4 · NEMA 4X housing

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16", 600V Rated Approvals: UL Listed, C-UL, CE, RoHS (All models) UL916 (RIB2401C) UL864, California State Fire Marshal (RIB2401C-RD) UL508 (RIB2401C-N4) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac

Coil Current: 24 mA @ 20 Vac 28 mA @ 24 Vac 44 mA @ 35 Vac 28 mA @ 120 Vac 13 mA @ 20 Vdc 16 mA @ 24 Vdc 25 mA @ 35 Vdc

26

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3.0 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

RELAYS

10 AMP PILOT CONTROL RELAY
RIBD2421C
Time Delay Pilot Relay, 10 Amp SPDT, 24 Vac/dc/120-277 Vac Coil, NEMA 1 Housing

Wht/Brn

Blu

120-277 Vac

N/C

Wht/Blu

Yel

24 Vac/dc

C

Wht/Yel

Org

Comm

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms after time delay Relay Status: RED LED On = Activated
Time Delay Status: PINK LED FLASHING = Timing Timing Mode: Delay On Make (N/O) Timing Range: 6 seconds - 20 minutes
Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range
Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5%
Timing Repeatability: +1% Temperature Timing Variance: +1%
Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple
Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1
Gold Flash: No Override Switch: No

Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty

Input Current: 66 mA @ 24 Vac 38 mA @ 24 Vdc 40 mA @ 120-277 Vac

Coil Voltage Input: 24 Vac/dc ; 120-277 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

Timing Adjustment
C BD AE

Range Selection 1234
Only Close 1 Switch

Depressed for closed
Depressed for open

Switch Ranges 6s-20s 22s-1min15s 1min30s-5min 6min-20min

TIMING TABLE

Close Dip Switch A

Potentiometer Setting

B

C

D

1

6s

9s

13s

16s

2

22s

36s

50s

1min4s

3

1min30s 2min10s 3min20s 4min16s

4

6min

9min

13min20s 17min20s

E 20s 1min15s 5min 20min

Coil
Time Delay N/O N/C
Time Delay

Timing Diagram
Time Delay Time Delay

Time Delay Time Delay

Time Delay Application
Load 2 stays on selected amount of time after Load 1 goes off.

Load 1
(Thermostat Controlled Heater,
for example)

In this example, voltage can be any voltage from 120-277 Vac.

Blu

Wht/Yel

Neutral

Blu

Load 2

(Circulating Fan, for example)

Yel
RIB®
Select RIB® with coil input appropriate to sense Load 1.

Wht/Brn

Yel

RIBD2421C

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

27

RELAYS

10 AMP PILOT CONTROL RELAY

RIBU2SC
Pilot Relays, 10 Amp SPST-N/O + Override + 1 SPDT,
10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing

Wht/Red

Gry

120 Vac

N/C

Gry/Wht

Prp

10-30 Vac/dc

C

Wht/Prp

Brn

Comm

N/O

Wht/Blk 120 Vac

Wht/Blu 10-30 Vac/dc
Wht/Yel Comm

CLOSED OPEN AUTO Org Org

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST + One (1) SPDT Continuous Duty Coil
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.75"NPT nipple
Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1
Gold Flash: Yes Override Switch: Yes

10 AMP PILOT CONTROL RELAY

RIBU2S2
Pilot Relays, 10 Amp 2 SPST-N/O + 2 Overrides,
10-30 Vac/dc/120 Vac Coil, NEMA 1 Housing

Wht/Blk 120 Vac

Wht/Blu 10-30 Vac/dc

CLOSED OPEN AUTO

Wht/Yel

Org

Comm

Org

Wht/Red 120 Vac

Gry/Wht 10-30 Vac/dc

CLOSED OPEN AUTO

Wht/Prp

Brn

Comm

Brn

SPECIFICATIONS
# Relays & Contact Type: Two (2) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2)

Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc
Notes: Order Normally Closed by adding "-NC" to end of model number

Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc
Notes: Order Normally Closed by adding "-NC" to end of model number

28

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

10 AMP PILOT CONTROL RELAYS

RIBTU1C
Pilot Relay, 10 Amp SPDT, 10-30 Vac/dc/ 120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

RIBTH1C
Pilot Relay, 10 Amp SPDT, 10-30 Vac/dc/ 208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Comm 10-30 Vac/dc
120 Vac

Blu - N/C Yel - C
Org - N/O

Comm 10-30 Vac/dc 208-277 Vac

Blu - N/C Yel - C
Org - N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

10 AMP PILOT CONTROL RELAYS

RIBTU2C
Pilot Relays, 10 Amp 2 SPDT, 10-30 Vac/dc/ 120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

RIBTH2C
Pilot Relays, 10 Amp 2 SPDT, 10-30 Vac/ dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Comm 10-30 Vac/dc 120 Vac

Comm 10-30 Vac/dc
120 Vac

Comm 10-30 Vac/dc 208-277 Vac

Comm 10-30 Vac/dc 208-277 Vac

Coil Current:

33 mA @ 10 Vac

13 mA @ 10 Vdc

35 mA @ 12 Vac

15 mA @ 12 Vdc

46 mA @ 24 Vac

18 mA @ 24 Vdc

55 mA @ 30 Vac

20 mA @ 30 Vdc

28 mA @ 120 Vac (RIBTU1C)

39 mA @ 208-277 Vac (RIBTH1C)

Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Blu - N/C Yel - C
Org - N/O

Brn - N/O Prp - C Gry - N/C

Blu - N/C Yel - C
Org - N/O

SPECIFICATIONS
# Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Brn - N/O Prp - C Gry - N/C
Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU2C) 39 mA @ 208-277 Vac (RIBTH2C)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

29

RELAYS

10 AMP PILOT CONTROL RELAYS

RIBU1CW
Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/
120 Vac Coil, Hi/Lo Vertical Separation,
NEMA 1 Housing

RIBH1CW
Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/
208-277 Vac Coil, Hi/Lo Vertical Separation,
NEMA 1 Housing

Comm
10-30 Vac/dc
120 Vac

Comm

N/O

N/O

10-30 Vac/dc

N/C

N/C

208-277

C

Vac

C

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 15 Amp Resistive @ 150 Vac, 28Vdc 15 Amp Inductive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

10 AMP PILOT CONTROL RELAYS

RIBTU1S
Pilot Relay, 10 Amp SPST + Override, 10-30 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

RIBTH1S
Pilot Relay, 10 Amp SPST + Override, 10-30 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Comm 10-30 Vac/dc
120 Vac

Selectable Jumper Wire
Org

CLOSED

Org

OPEN

AUTO

Comm 10-30 Vac/dc 208-277 Vac

Selectable Jumper Wire
Org

CLOSED

Org

OPEN

AUTO

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1CW) 39 mA @ 208-277 Vac (RIBH1CW)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1CW) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1CW) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes

Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)
Notes: · Normally Open or Normally Closed
selected by yellow jumper wire

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1S) 39 mA @ 208-277 Vac (RIBTH1S)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

30

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

10 AMP PILOT CONTROL RELAYS

RIBTU1SC
Pilot Relay, 10 Amp SPDT + Override, 10-30 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

RIBTH1SC
Pilot Relay, 10 Amp SPDT + Override, 10-30 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Comm 10-30 Vac/dc

Blu N/C N/C - CLOSED
OPEN
Org N/O N/O - CLOSED

Comm 10-30 Vac/dc

Blu N/C N/C - CLOSED
OPEN
Org N/O N/O - CLOSED

120 Vac

MANUAL

Yel

C

AUTO

208-277 Vac

MANUAL

Yel

C

AUTO

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2)
10 AMP PILOT CONTROL RELAY
RIBT2401D
Pilot Relay, 10 Amp DPDT, 24 Vac/dc/ 120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1SC) 39 mA @ 208-277 Vac (RIBTH1SC)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

120 Vac 24 Vac/dc
Comm

Blu - N/C Yel - C
Org - N/O Gry - N/C
Prp - C Brn - N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max

Coil Current: 24 mA @ 18 Vac 32 mA @ 24 Vac 40 mA @ 30 Vac 31 mA @ 120 Vac 20 mA @ 20 Vdc 24 mA @ 24 Vdc 36 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

31

RELAYS
NC C NO

10 AMP PILOT CONTROL RELAY
RIBRL1C-NS
DIN Rail Mount Relay, 10 Amp SPDT, 10-30 Vac/dc Coil, No Socket Non-Pluggable Relay

10-30 Vac/dc

N/O

C

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m 2.76"

10-30V COM

Comm

N/C

Relay LED

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Accessories: ADIN35, ADIN35ES

ADIN35ES

3.88"

Pair of End Stops

for 35mm DIN Rail 0.78"

Contact Ratings: 10 Amp Resistive @ 120/240/277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120/240 Vac (N/O) 1/6 HP @ 120/240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Notes: Models ADIN35 and ADIN35ES sold separately.

10 AMP PILOT CONTROL RELAY
RIBRL1S-NS
DIN Rail Mount Relay, 10 Amp SPDT + Override, 10-30 Vac/dc Coil, No Socket Non-Pluggable Relay

PWR Closed N/O
CTRL Open Auto
C

Comm

N/C

PWR CTRL COM
CLOSED OPEN AUTO

Override Switch
Relay LED Not Used
Apply Continuous Power (10-30Vac/dc) to PWR and COM. Apply Coil Control (10-30Vac/dc) to CTRL and COM.

NC C NO

2.76"

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

ADIN35ES

3.88"

Pair of End Stops

0.78" for 35mm DIN Rail

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc
Notes: Models ADIN35 and ADIN35ES sold separately.

32

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NO2 NO1 C2 C1
RELAYS

10 AMP PILOT CONTROL RELAY
RIBR24D-NS
DIN Rail Mount Relay, 10 Amp DPDT, 24 Vac/dc Coil, No Socket Non-Pluggable Relay

24Vac/dc
Comm NC1

NO1 C1
NO2 C2

24Vac/dc COM NC1 NC2

Relay LED Not Used

2.76"

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

NC2

ADIN35ES

3.88"

Pair of End Stops

0.78"

for 35mm DIN Rail

SPECIFICATIONS

# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/C) B300 Pilot Duty  120Vac 30A Make 3A Break (360 VA)  240Vac 15A Make 1.5A Break (360 VA)  208Vac 17.3A Make 1.73A Break (360 VA)  277Vac 13A Make 1.3A Break (360 VA)  24Vac 30A Make 5A Break (120VA) 5A Max

Power and Control Current:

24 mA @ 18 Vac

20 mA @ 20 Vdc

32 mA @ 24 Vac

24 mA @ 24 Vdc

40 mA @ 30 Vac

36 mA @ 24 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc
Notes: Models ADIN35 and ADIN35ES sold separately.

10 AMP PILOT CONTROL RELAY
RIBR24SD-NS
DIN Rail Mount Relay, 10 Amp DPDT + Override, 24 Vac/dc Coil, No Socket Non-Pluggable Relay

CLOSED

NO2 NO1 C2 C1

PWR CTRL COM

PWR Closed
CTRL Open Auto

NO1 C1

AUTO

OPEN

Override Switch
Relay LED Not Used

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

NC1 NC2

Comm NC1 NC2
SPECIFICATIONS

NO2 C2

Apply Continuous Power (24Vac/dc) to PWR and COM.
Apply Coil Control (24Vac/dc) to CTRL and COM.

2.76" 3.88"

ADIN35ES

Pair of End Stops

0.78"

for 35mm DIN Rail

# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/C) B300 Pilot Duty  120Vac 30A Make 3A Break (360 VA)  240Vac 15A Make 1.5A Break (360 VA)  208Vac 17.3A Make 1.73A Break (360 VA)  277Vac 13A Make 1.3A Break (360 VA)  24Vac 30A Make 5A Break (120VA) 5A Max

Power and Control Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 24 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc
Notes: Models ADIN35 and ADIN35ES sold separately.

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

33

RELAYS
NC C NO

10 AMP PILOT CONTROL RELAY
RIBRL1C
DIN Rail Mount Relay, 10 Amp SPDT, 10-30 Vac/dc Coil, Replaceable Relay

10-30 Vac/dc

N/O

C

Comm

N/C

10-30V COM

Relay LED Not Used
Open Lid this Side

2.76"

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes
Replacement Relay: ARL1C Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

ADIN35ES

Pair of End Stops

3.88"

0.78"

for 35mm DIN Rail

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Notes: Models ADIN35 and ADIN35ES sold separately.

10 AMP PILOT CONTROL RELAY
RIBRL1S
DIN Rail Mount Relay, 10 Amp SPDT + Override, 10-30 Vac/dc Coil, Replaceable Relay

PWR Closed N/O
CTRL Open Auto
C

PWR CTRL COM
CLOSED OPEN AUTO

Override Switch
Relay LED Not Used
Open Lid this Side

NC C NO

2.76"

Apply Continuous Power (10-30Vac/dc) to PWR and COM.

Comm

N/C

Apply Coil Control (10-30Vac/dc)

to CTRL and COM.

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes
Replacement Relay: ARL1C Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

ADIN35ES

3.88"

Pair of End Stops

0.78"

for 35mm DIN Rail

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc
Notes: Models ADIN35 and ADIN35ES sold separately.

34

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

NO2 NO1 C2 C1
RELAYS

10 AMP PILOT CONTROL RELAY
RIBR24D
DIN Rail Mount Relay, 10 Amp DPDT, 24 Vac/dc Coil, Replaceable Relay

24Vac/dc
Comm NC1 NC2

NO1 C1
NO2 C2

24Vac/dc COM NC1 NC2

Relay LED Not Used
Open Lid this Side

2.76" 3.88"

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

ADIN35ES

Pair of End Stops

0.78"

for 35mm DIN Rail

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS
Replacement Relay: AR24D Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/C) B300 Pilot Duty  120Vac 30A Make 3A Break (360 VA)  240Vac 15A Make 1.5A Break (360 VA)  208Vac 17.3A Make 1.73A Break (360 VA)  277Vac 13A Make 1.3A Break (360 VA)  24Vac 30A Make 5A Break (120VA) 5A Max

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc
Power and Control Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 24 Vdc
Notes: Models ADIN35 and ADIN35ES sold separately.

10 AMP PILOT CONTROL RELAY
RIBR24SD
DIN Rail Mount Relay, 10 Amp DPDT + Override, 24 Vac/dc Coil, Replaceable Relay

CLOSED

PWR CTRL COM

PWR Closed
CTRL Open Auto

NO1 C1

AUTO

OPEN

Override Switch
Relay LED Not Used

NO2 NO1 C2 C1

2.76"

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

NC1 NC2

Comm NC1 NC2
SPECIFICATIONS

NO2 C2

Open Lid this Side
Apply Continuous Power (24Vac/dc) to PWR and COM.
Apply Coil Control (24Vac/dc) to CTRL and COM.

3.88"

ADIN35ES

0.78"

Pair of End Stops for 35mm DIN Rail

# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS
Replacement Relay: AR24D Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120-240 Vac (N/O) 1/3 HP @ 120-240 Vac (N/C) B300 Pilot Duty  120Vac 30A Make 3A Break (360 VA)  240Vac 15A Make 1.5A Break (360 VA)  208Vac 17.3A Make 1.73A Break (360 VA)  277Vac 13A Make 1.3A Break (360 VA)  24Vac 30A Make 5A Break (120VA) 5A Max

Power and Control Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 24 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc
Notes: Models ADIN35 and ADIN35ES sold separately.

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

35

RELAYS

10 AMP PILOT CONTROL TRACK OR DIN MOUNT RELAYS

RIBAN12C
Pilot Relay, 10 Amp SPDT, 12 Vac/dc Coil, DIN Rail Mountable, Current Sensor Mount Option, 2.75"Track Mount

RIBAN24C
Pilot Relay, 10 Amp SPDT, 24 Vac/dc Coil, DIN Rail Mountable, Current Sensor Mount Option, 2.75"Track Mount

12 Vac/dc

24 Vac/dc

N/O

N/O

C

C

N/C

N/C

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 2.85"H x 2.75"W x 1.03"D
Housing Detail: See Housing I in housing guide for dimensions Origin: Made of US and non-US parts
Terminals: Removable, Accepts 22-16 AWG copper wires
Mounting: A: 2.750 Track Mount MT212 Mounting Track Sold Separately.
B: 35mm x 7.5mm symmetrical DIN rail EN50022 C: Screw Mount
DS80625 Self-Tapping Drill Screws Sold Separately. D: Current Sensor Mount Current Sensors Sold Separately.
Approvals: UL Listed, UL508, C-UL, CE, RoHS Gold Flash: No Override Switch: No
RELAY MOUNTING OPTIONS A & B

Mounting Option A:
2.75" Track Mount MT212 Series

K G

Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty
Coil Voltage Input: (RIBAN12C) 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc
Coil Current: (RIBAN12C) 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc

REMOVABLE TERMINALS
Notes: · Set of replacement terminals available. Order model number: TS-AN
Coil Voltage Input: (RIBAN24C) 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc
Coil Current: (RIBAN24C) 26 mA @ 20 Vac 31 mA @ 24 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc

Mounting Option B:

K G

35mm x 7.5mm symmetrical DIN rail EN50022

CURRENT SENSOR MOUNTING OPTION D

K
RIBXK Series Mounting
Tab

G
RIBXG Series Mounting
Tab

1. Slide current sensor onto corresponding mounting tab.
2. Snap into place.
3. Depress tab to remove current sensor.

36

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

10 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBM12C
Pilot Relay, 15 Amp SPDT, 12 Vac/dc Coil,
4.00" Track Mount

RIBM12S
Pilot Relay, 15 Amp SPST + Override,
12 Vac/dc Coil, 4.00" Track Mount

RELAYS

Comm

N/C

Comm

AUTO

C

OPEN

CLOSED

C

12 Vac/dc

N/O

12 Vac/dc

N/O or N/C
Selectable Jumpers (must cut one only)

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBM12C) One (1) SPST Continuous Duty Coil (RIBM12S)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.25"H x 4.00"W x 0.75"D1/1.25"D2 (RIBM12C) 1.25"H x 4.00"W x 1.00"D1/1.50"D2 (RIBM12S)
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 4.000 MT4 Mounting Track Sold Separately
Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal
Gold Flash: No Override Switch: No (RIBM12C) ; Yes (RIBM12S)

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty

10 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBM24C
Pilot Relay, 15 Amp SPDT, 24 Vac/dc Coil,
4.00" Track Mount

RIBM24S
Pilot Relay, 15 Amp SPST + Override,
24 Vac/dc Coil, 4.00" Track Mount

Cut for N/O
Cut for N/C

Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 36 mA @ 12 Vdc

Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc

Notes: Must cut appropriate jumper to select Normally Open or Normally Closed (RIBM12S)

Comm

N/C

C

24 Vac/dc

N/O

Comm 24 Vac/dc

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBM24C) One (1) SPST Continuous Duty Coil (RIBM24S)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.25"H x 4.00"W x 0.75"D1/1.25"D2 (RIBM24C) 1.25"H x 4.00"W x 1.25"D1/1.75"D2 (RIBM24S)
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 4.000 MT4 Mounting Track Sold Separately
Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal
Gold Flash: No Override Switch: No (RIBM24C) ; Yes (RIBM24S)

AUTO

C

OPEN

CLOSED

N/O or N/C

Selectable Jumpers (must cut one only)

Cut for N/O
Cut for N/C

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty

Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

Notes: Must cut appropriate jumper to select Normally Open or Normally Closed (RIBM24S)

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

37

RELAYS

10 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBM2401D
Pilot Relay, 10 Amp DPDT, 24 Vac/dc/
120 Vac Coil, 4.00" Track Mount

RIBM2402D
Pilot Relay, 10 Amp DPDT, 24 Vac/dc/
208-277 Vac Coil, 4.00" Track Mount

N/O 120 Vac
C
N/C 24 Vac/dc
N/O
C Comm
N/C

N/O 208-277 Vac
C
N/C 24 Vac/dc
N/O
C Comm
N/C

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.70"H x 4.00"W x 0.75"D1/1.25"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: No

Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMU1C
Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/
120 Vac Coil, 4.00" Track Mount

RIBMH1C
Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/
208-277 Vac Coil, 4.00" Track Mount

Coil Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 30 Vdc 31 mA @ 120 Vac (RIBM2401D) 36 mA @ 208-277 Vac (RIBM2402D)
Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401D) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402D) Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc

Comm

N/C

10-30 Vac/dc

C

120 Vac

N/O

Comm

N/C

10-30 Vac/dc

C

208-277 Vac

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.25"H x 4.00"W x 0.88"D1/1.38"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: No

Contact Ratings: 15 Amp Inductive @ 150 Vac 15 Amp Resistive @ 150 Vac, 28 Vdc 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1C) 39 mA @ 208-277 Vac (RIBMH1C)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

38

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMU1S
Pilot Relay, 15 Amp SPST-N/O + Override,
10-30 Vac/dc/120 Vac Coil, 4.00" Track Mount

RIBMH1S
Pilot Relay, 15 Amp SPST-N/O + Override,
10-30 Vac/dc/208-277 Vac Coil, 4.00" Track Mount

Comm 10-30 Vac/dc
120 Vac

AUTO OPEN CLOSED

Comm 10-30 Vac/dc 208-277 Vac

AUTO OPEN CLOSED

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.28"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: Yes

Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)
Notes: · Order Normally Closed by adding "-NC"
to end of model number

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMU2C
Pilot Relays 15 Amp 2 SPDT, 10-30 Vac/dc/
120 Vac Coil, 4.00" Track Mount

RIBMH2C
Pilot Relays 15 Amp 2 SPDT, 10-30 Vac/dc/
208-277 Vac Coil, 4.00" Track Mount

Comm

N/C

Comm

N/C

10-30 Vac/dc

C

10-30 Vac/dc

C

120 Vac

N/O

Comm

N/C

208-277 Vac

N/O

Comm

N/C

10-30 Vac/dc

C

10-30 Vac/dc

C

120 Vac

N/O

208-277 Vac

N/O

Coil Current:

33 mA @ 10 Vac

13 mA @ 10 Vdc

35 mA @ 12 Vac

15 mA @ 12 Vdc

46 mA @ 24 Vac

18 mA @ 24 Vdc

55 mA @ 30 Vac

20 mA @ 30 Vdc

28 mA @ 120 Vac (RIBMU1S)

39 mA @ 208-277 Vac (RIBMH1S)

Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

SPECIFICATIONS
# Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.45"H x 4.00"W x 0.88"D1/1.38"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: No

Contact Ratings: 15 Amp Inductive @ 150 Vac 15 Amp Resistive @ 150 Vac, 28 Vdc 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU2C) 39 mA @ 208-277 Vac (RIBMH2C)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

39

RELAYS

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMU1SM-250
Pilot Relay, 15 Amp SPST + Override + Monitor, 10-30 Vac/dc/120 Vac Coil, 4.00" Track Mount

RIBMH1SM-250
Pilot Relay, 15 Amp SPST + Override + Monitor, 10-30 Vac/dc/208-277 Vac Coil, 4.00" Track Mount

Closed C
Auto
Comm

CLOSED OPEN AUTO
Selectable Jumper Wire

Closed C
Auto
Comm

CLOSED OPEN AUTO
Selectable Jumper Wire

10-30 Vac/dc 120 Vac

CLOSED OPEN AUTO

10-30 Vac/dc 208-277 Vac

CLOSED OPEN AUTO

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.00"H x 4.00"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: Yes + Monitor

Contact Ratings: 15 Amp Resistive @ 125 Vac 10 Amp Resistive @ 250 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 1/3 HP for N/O @ 120-240 Vac 1/6 HP for N/C @ 120-240 Vac
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMU1SC
Pilot Relay, 15 Amp SPDT + Override,
10-30 Vac/dc/120 Vac Coil, 4.00" Track Mount

RIBMH1SC
Pilot Relay, 15 Amp SPDT + Override,
10-30 Vac/dc/208-277 Vac Coil, 4.00" Track Mount

Coil Current:

33 mA @ 10 Vac

13 mA @ 10 Vdc

35 mA @ 12 Vac

15 mA @ 12 Vdc

46 mA @ 24 Vac

18 mA @ 24 Vdc

55 mA @ 30 Vac

20 mA @ 30 Vdc

28 mA @ 120 Vac (RIBMU1SM-250)

39 mA @ 208-277 Vac (RIBMH1SM-250)

Notes: · Normally Open or Normally Closed selected by yellow jumper wire · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 50 Vac/dc, 0.25 Amp max

Comm

10-30 Vac/dc AUTO C

120 Vac

MANUAL

N/O

N/C

CLOSED

CLOSED

N/C

OPEN

N/O

Comm

10-30 Vac/dc AUTO C

208-277 Vac

MANUAL

N/O

N/C

CLOSED

CLOSED

N/C

OPEN

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.50"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: Yes (2)

Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1SC) 39 mA @ 208-277 Vac (RIBMH1SC)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

40

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMN12C
Pilot Relay, 15 Amp SPDT, 12 Vac/dc Coil,
2.75" Track Mount

RIBMN12S
Pilot Relay, 15 Amp SPST + Override,
12 Vac/dc Coil, 2.75" Track Mount

RELAYS

Comm

N/C

C

12 Vac/dc

N/O

Comm 12 Vac/dc

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN12C) One (1) SPST Continuous Duty Coil (RIBMN12S)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.10"H x 2.75"W x 0.75"D1/1.25"D2 (RIBMN12C) 1.25"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMN12S)
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 2.750 MT212 Mounting Track Sold Separately
Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal
Gold Flash: No Override Switch: No (RIBMN12C) ; Yes (RIBMN12S)

AUTO

C

OPEN

CLOSED

N/O or N/C
Selectable Jumpers (must cut one only)
Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty

Cut for N/O

Cut for N/C

Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc

Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc

Notes: (RIBMN12S) · Must cut appropriate jumper to select Normally Open or Normally Closed

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMN24C
Pilot Relay, 15 Amp SPDT, 24 Vac/dc Coil,
2.75" Track Mount

RIBMN24S
Pilot Relay, 15 Amp SPST + Override,
24 Vac/dc Coil, 2.75" Track Mount

24 Vac/dc

N/C

C

Comm

N/O

Comm 24 Vac/dc

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN24C) One (1) SPST Continuous Duty Coil (RIBMN24S)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.10"H x 2.75"W x 0.75"D1/1.25"D2 (RIBMN2CS) 1.25"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMN24S)
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 2.750 MT212 Mounting Track Sold Separately
Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal
Gold Flash: No Override Switch: No (RIBMN24C) ; Yes (RIBMN24S)

AUTO

C

OPEN

CLOSED

N/O or N/C
Selectable Jumpers (must cut one only)

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty

Cut for N/O

Cut for N/C

Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

Notes: (RIBMN24S) · Must cut appropriate jumper to select Normally Open or Normally Closed

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

41

15 AMP PILOT CONTROL TRACK MOUNT RELAY
RIBMN24S-J
Pilot Relay, 15 Amp SPST + Override, 24 Vac/dc Coil, Jumper Selectable Output, 2.75" Track Mount

Comm

AUTO OPEN CLOSED

RELAYS

24 Vac/dc

Selectable Jumper Wire

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.25"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: Yes

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMN24C-4T
Four Pilot Relays, 15 Amp SPDT, 24 Vac/dc Coil,
2.75" x 6.00" Track Mount

RIBMN24S-4T
Four Pilot Relays, 15 Amp SPST + Override,
24 Vac/dc Coil, 2.75" x 6.00" Track Mount

Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

Notes: Normally Open or Normally Closed selected by yellow jumper wire.

Comm

N/C

C

24 Vac/dc

N/O

Comm 24 Vac/dc

AUTO

C

OPEN

CLOSED

N/O or N/C
Selectable Jumpers (must cut one only)

SPECIFICATIONS
# Relays & Contact Type: Four (4) SPDT Continuous Duty Coils (RIBMN24C-4T) Four (4) SPST Continuous Duty Coils (RIBMN24S-4T)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.25"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMN24C-4T) 1.25"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMN24S-4T)
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 2.750 x 6.000 ; MT212-6 Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No
Override Switch: No (RIBMN24C-4T) ; Yes (RIBMN24S-4T)

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty

Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

Notes: Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S-4T)

42

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

10 AMP PILOT CONTROL TRACK MOUNT RELAYS
RIBMN2401D
Pilot Relay, 10 Amp DPDT, 24 Vac/dc/ 120 Vac Coil, 2.75" Track Mount

N/O 120 Vac
C
N/C 24 Vac/dc
N/O
C Comm
N/C

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.75"W x 0.75"D1/1.25"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: No Override Switch: No

Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max

Coil Current: 36 mA @ 30Vdc 24 mA @ 18 Vac 32 mA @ 24 Vac 40 mA @ 30 Vac 31 mA @ 120 Vac

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMNU1C
Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/
120 Vac Coil, 2.75" Track Mount

RIBMNH1C
Pilot Relay, 15 Amp SPDT, 10-30 Vac/dc/
208-277 Vac Coil, 2.75" Track Mount

Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc

Comm

N/C

10-30 Vac/dc

C

120 Vac

N/O

Comm

N/C

10-30 Vac/dc

C

208-277 Vac

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.75"W x 0.88"D1/1.38"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: No

Contact Ratings: 15 Amp Resistive @ 150 Vac, 28Vdc 15 Amp Inductive @ 150 Vac 10 Amp Resistive @ 120-277 Vac, 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

Coil Current:

33 mA @ 10 Vac

13 mA @ 10 Vdc

35 mA @ 12 Vac

15 mA @ 12 Vdc

46 mA @ 24 Vac

18 mA @ 24 Vdc

55 mA @ 30 Vac

20 mA @ 30 Vdc

28 mA @ 120 Vac (RIBMNU1C)

39 mA @ 208-277 Vac (RIBMNH1C)

Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

43

RELAYS

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMNU1S
Pilot Relay, 15 Amp SPST + Override,
10-30 Vac/dc/120 Vac Coil, 2.75" Track Mount

RIBMNH1S
Pilot Relay, 15 Amp SPST + Override,
10-30 Vac/dc/208-277 Vac Coil, 2.75" Track Mount

Comm

Comm

10-30 Vac/dc 120 Vac

AUTO OPEN CLOSED

10-30 Vac/dc 208-277 Vac

AUTO OPEN CLOSED

Selectable Jumper Wire

Selectable Jumper Wire

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.53"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, C-UL, CE, RoHS UL864, California State Fire Marshal Gold Flash: Yes Override Switch: Yes

Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)
Notes: Normally Open or Normally Closed selected by yellow jumper wire

15 AMP PILOT CONTROL TRACK MOUNT RELAYS

RIBMNU1SM-250
Pilot Relay, 15 Amp SPST + Override + Monitor, 10-30 Vac/dc/120 Vac Coil, 2.75 Track Mount

RIBMNH1SM-250
Pilot Relay, 15 Amp SPST + Override + Monitor, 10-30 Vac/dc/208-277 Vac Coil, 2.75 Track Mount

120 Vac

Selectable Jumper Wire

208-277 Vac

Selectable Jumper Wire

10-30 Vac/dc
Comm

CLOSED OPEN AUTO
AUTO
C CLOSED

CLOSED OPEN AUTO

10-30 Vac/dc
Comm

CLOSED OPEN AUTO
AUTO
C CLOSED

CLOSED OPEN AUTO

Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMNU1S) 39 mA @ 208-277 Vac (RIBMNH1S)
Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 3.38"H x 2.75"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes (with Monitor)

Contact Ratings: 15 Amp Resistive @ 125 Vac 10 Amp Resistive @ 250 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C)
Notes: · Normally Open or Normally Closed selected by yellow jumper wire · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 50 Vac/dc, 0.25 Amp max

Coil Current:

33 mA @ 10 Vac

13 mA @ 10 Vdc

35 mA @ 12 Vac

15 mA @ 12 Vdc

46 mA @ 24 Vac

18 mA @ 24 Vdc

55 mA @ 30 Vac

20 mA @ 30 Vdc

28 mA @ 120 Vac (RIBMNU1SM-250)

39 mA @ 208-277 Vac (RIBMNH1SM-250)

Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

44

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER RELAYS: 20­30 AMPS

RIBT2401D

RIB2421SB

RIB2402B

RIBM2401SBC

RIBM24ZL

Convenient Prepackaging is a Great Time Saver

· LED indicator · Multiple contact ratings · Override / HOA switch options available · High/low voltage separation available

· 20-30 Amp models · Pre-wired · Enclosed or track mount · Time delay models

ENCLOSED POWER RELAYS

COIL VOLTAGE

CONTACT RATINGS

RELAY

MODEL #

AC/DC

AC

CONTACTS RESISTIVE

RIB2401B · 24

120

1 SPDT 20 A @ 277 Vac

MOTOR 2 HP @ 277 Vac

PILOT DUTY 1,110 VA @ 277 Vac

HIGH/LOW OVERRIDE HOUSING SEPARATION SWITCH STYLE *
B

SPEC PAGE
47

RIB2402B · 24

208-277

1 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

B

47

RIB2401SB · 24

120

1 SPST 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

1

B

47

RIB2402SB · 24

208-277

1 SPST 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

1

B

47

RIB2421B · 24 120/208-277 1 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

B

48

RIB2421SB · 24 120/208-277 1 SPST 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

1

B

48

RIB2401SBC · 24

120

1 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

2 +

B

48

RIB2402SBC · 24

208-277

1 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

2 +

B

48

RIB2401B2G · 24

120

1 DPDT

5 A @ 480 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

B

49

RIB2402B2G · 24

208-277

1 DPDT

5 A @ 480 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

B

49

RIB01P

·

120

1 DPDT 20 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

C

49

RIB02P

·

208-277

1 DPDT 20 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

C

49

RIB347P

·

347

1 DPDT 20 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

C

50

RIB04P

·

480

1 DPDT 20 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

C

50

RIB013P

·

120

1 3PST 20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

C

50

RIB023P

·

208-277

1 3PST 20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

C

50

RIB043P

·

480

1 3PST 20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

C

51

RIB243P

· 24

1 3PST 20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

C

51

RIB24Z RIB12P

· 24 · 12

1 SPST N/O, 1 SPST N/C
1 DPDT

30 A @ 300 Vac 20 A @ 300 Vac

3 HP @ 480-600 Vac 3 HP @ 480-600 Vac

Heavy Pilot Duty @ 600 Vac Heavy Pilot Duty @ 600 Vac

B

51

B

52

RIB12P30 · 12

1 DPDT 30 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

B

52

RIB24P

· 24

1 DPDT 20 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

B

52

RIB24P30 · 24

1 DPDT 30 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

B

52

RIB01P30 ·

120

1 DPST 30 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

C

53

RIB01P30-S ·

120

1 DPST 30 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

1 #

C

53

RIB02P30 ·

208-277

1 DPST 30 A @ 300 Vac

3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

C

53

= UL Listed - see data sheet for specific Listing + = SPDT with override requires 2 switches

* = See Housing Guide on page 201 # = Coil side relay override (requires unit to be powered)

(800) 888-5538 | www.functionaldevices.com

45

RELAYS

POWER RELAYS: 20­30 AMPS

T STYLE POWER RELAYS

COIL VOLTAGE

CONTACT RATINGS

MODEL # RIBT24B

AC/DC AC
· 24

RELAY CONTACTS
1 SPDT

RESISTIVE 20 A @ 277 Vac

MOTOR 2 HP @ 277 Vac

PILOT DUTY 1,110 VA @ 277 Vac

HIGH/LOW OVERRIDE HOUSING SPEC SEPARATION SWITCH STYLE * PAGE

·

C

54

RIBT24SB

· 24

1 SPST 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

1

C

54

RIBT2401B

· 24

120

1 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

C

54

RIBT2402B

· 24 208-277 1 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

C

54

RIBT2401SB · 24

120

1 SPST 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

1

C

55

RIBT2402SB · 24 208-277 1 SPST 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

1

C

55

RIBT2401SBC · 24

120

1 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

2 +

C

55

RIBT2402SBC · 24 208-277 1 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

2 +

C

55

RIBTD2401B ~ · 24

120

1 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

C

56

RIBT242B

· 24

2 SPDT 20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

C

57

RIBT243B RIBT24P

· 24 · 24

2 SPST, 1 SPDT

20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

1 DPDT 20 A @ 300 Vac 3 HP @ 480-600 Vac Heavy Pilot Duty @ 600 Vac

·

C

57

C

57

RIBT24Z RIBT243P

· 24 · 24

1 SPST N/O, 1 SPST N/C

30 A @ 300 Vac

3 HP @ 480-600 Vac

Heavy Pilot Duty @ 600 Vac

·

3PST

20 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

·

C

58

C

58

TRACK MOUNT POWER RELAYS

COIL VOLTAGE

MODEL # RIBM2401B RIBM2402B RIBM2401SB RIBM2402SB RIBM2401SBC RIBM2402SBC

AC/DC

·

24

·

24

·

24

·

24

·

24

·

24

AC 120 208-277 120 208-277 120 208-277

RELAY CONTACTS
1 SPDT 1 SPDT 1 SPST 1 SPST 1 SPDT 1 SPDT

RESISTIVE 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac

CONTACT RATINGS

MOTOR 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac

PILOT DUTY 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac

OVERRIDE TRACK

SPEC

SWITCH MOUNT ^ PAGE

MT4 Series

59

MT4 Series

59

1

MT4 Series

59

1

MT4 Series

59

2 +

MT4 Series

60

2 +

MT4 Series

60

RIBM24ZN

24

RIBM24ZL

·

24

RIBMN24ZL

·

24

1 DPDT 1 DPST 1 DPST

30 A @ 300 Vac 30 A @ 300 Vac 30 A @ 300 Vac

3 HP @ 480-600 Vac 3 HP @ 480-600 Vac 3 HP @ 480-600 Vac

NEMA B600 Heavy Pilot Duty @ 600 Vac Heavy Pilot Duty @ 600 Vac

MT4 Series

60

MT4 Series

61

MT212 Series

61

RIBM243PN

24

1 3PDT

30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series

61

RIBM013PN

120

1 3PDT

30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series

62

RIBM023PN

208-277

1 3PDT

30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series

62

RIBM043PN

480

1 3PDT

30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series

63

RIBM043PN-HD

480

1 3PDT

30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac

MT4 Series

63

= UL Listed - see data sheet for specific Listing = UL Component Recognized - see data sheet for specific Listing

~ = Time Delay + = SPDT with override requires 2 switches

* = See Housing Guide on page 201 ^ = Track mount sold separately

46

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

20 AMP POWER CONTROL RELAYS

RIB2401B
Power Relay, 20 Amp SPDT,
24 Vac/dc/120 Vac Coil, NEMA 1 Housing

RIB2402B
Power Relay, 20 Amp SPDT,
24 Vac/dc/208-277 Vac Coil, NEMA 1 Housing

Wht/Blk

Blu

120 Vac

N/C

Wht/Blu

Yel

24 Vac/dc

C

Wht/Yel

Org

Comm

N/O

Wht/Brn

Blu

208-277 Vac

N/C

Wht/Blu

Yel

24 Vac/dc

C

Wht/Yel

Org

Comm

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIB2401B) 69mA @ 208-277 Vac (RIB2402B)

33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

20 AMP POWER CONTROL RELAYS

RIB2401SB
Power Relay, 20 Amp SPST-N/O + Override,
24 Vac/dc/120 Vac Coil, NEMA 1 Housing

RIB2402SB
Power Relay, 20 Amp SPST-N/O + Override,
24 Vac/dc/208-277 Vac Coil, NEMA 1 Housing

Wht/Blk 120 Vac
Wht/Blu 24 Vac/dc
Wht/Yel Comm

CLOSED OPEN AUTO
Org Org

Wht/Brn 208-277 Vac
Wht/Blu 24 Vac/dc
Wht/Yel Comm

CLOSED OPEN AUTO
Org Org

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

(800) 888-5538 | www.functionaldevices.com

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIB2401SB) 69 mA @ 208-277 Vac (RIB2402SB) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Notes: · Order Normally Closed by adding "-NC" to end of model number
47

RELAYS

20 AMP POWER CONTROL RELAYS

RIB2421B
Power Relay, 20 Amp SPDT, 24 Vac/dc/120 Vac/208-277 Vac Coil, NEMA 1 Housing

RIB2421SB
Power Relay, 20 Amp SPST-N/O + Override, 24 Vac/dc/208-277 Vac/120 Vac Coil, NEMA 1 Housing

Wht/Brn

Blu

208-277 Vac

N/C

Wht/Blk 120 Vac
Yel C Wht/Blu 24 Vac/dc

Wht/Yel

Org

Comm

N/O

Wht/Brn 208-277 Vac
Wht/Blk 120 Vac
Wht/Blu 24 Vac/dc
Wht/Yel Comm

CLOSED OPEN AUTO
Org Org

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIB2421B) One (1) SPST Continuous Duty Coil (RIB2421SB)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple
Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1
Gold Flash: No Override Switch: Yes (RIB2421SB)
No (RIB2421B)

Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) (RIB2421SB) Not rated for Electronic Ballast (RIB2421SB) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

20 AMP POWER CONTROL RELAYS

RIB2401SBC
Power Relay, 20 Amp SPDT + Override,
24 Vac/dc/120 Vac Coil, NEMA 1 Housing

RIB2402SBC
Power Relay, 20 Amp SPDT + Override,
24 Vac/dc/208-277 Vac Coil, NEMA 1 Housing

Coil Current: 83 mA @ 24 Vac 47 mA @ 120 Vac 69 mA @ 208-277 Vac 47 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 208-277 Vac ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc
Notes: · Order RIB2421SB Normally Closed by adding "-NC" to end of model number

Wht/Blk 120 Vac

Wht/Blu 24 Vac/dc

Yel C

MANUAL

Wht/Yel Comm

AUTO

Blu N/C

Org

OPEN

N/O

N/C N/O CLOSED CLOSED

Wht/Brn 208-277 Vac

Wht/Blu 24 Vac/dc

Yel C

MANUAL

Wht/Yel Comm

AUTO

Blu N/C

Org

OPEN

N/O

N/C N/O CLOSED CLOSED

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2)

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIB2401SBC) 69 mA @ 208-277 Vac (RIB2402SBC)

33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

48

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

20 AMP POWER CONTROL RELAYS

RIB2401B2G
Power Relay, 20 Amp DPDT,
24 Vac/dc/120 Vac Coil, NEMA 1 Housing

RIB2402B2G
Power Relay, 20 Amp DPDT,
24 Vac/dc/208-277 Vac Coil, NEMA 1 Housing

Wht/Blk 120 Vac
Wht/Blu 24 Vac/dc
Wht/Yel Comm

Blu N/C Yel C Org N/O
Gry N/C Prp C Brn N/O

Wht/Brn 208-277 Vac
Wht/Blu 24 Vac/dc
Wht/Yel Comm

Blu N/C Yel C Org N/O
Gry N/C Prp C Brn N/O

SPECIFICATIONS
# Relays & Contact Type: DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .75 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 20 A @ 277 Vac General Purpose 20 A @ 28 Vdc 1 HP @ 120 Vac 2 HP @ 277 Vac 2 HP @ 240 Vac (N/O) 1 HP @ 208 Vac (N/O) 20 A Ballast @ 277 Vac 15 A Tungsten @ 120 Vac (N/O) 5 A @ 480 Vac Resistive 16 A @ 277 Vac Electronic Ballast (N/O) 1,110 VA Pilot Duty @ 277 Vac 1,158 VA Pilot Duty @ 240 Vac (N/O) 770 VA Pilot Duty @ 208 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 2 A Tungsten @ 120 Vac (N/C)

20 AMP POWER CONTROL RELAYS

RIB01P
Power Relay, 20 Amp DPDT, 120 Vac Coil,
NEMA 1 Housing

RIB02P
Power Relay, 20 Amp DPDT, 208-277 Vac Coil,
NEMA 1 Housing

Blu N/C

Wht/Blk

120 Vac

Yel

C

Org N/O
Gry N/C

Wht/Blk

Prp

120 Vac

C

Brn N/O

Blu N/C

Wht/Brn

208-277 Vac

Yel

C

Org N/O
Gry N/C

Wht/Brn

Prp

208-277 Vac

C

Brn N/O

Coil Current: 145 mA max @ 24 Vac 65 mA max @ 30 Vdc 107 mA max @ 120 Vac (RIB2401B2G) 140 mA max @ 208-277 Vac (RIB2402B2G)
Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401B2G) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402B2G) Drop Out = 13.5 Vac / 15.5 Vdc Pull In = 18 Vac / 22 Vdc

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

(800) 888-5538 | www.functionaldevices.com

Coil Current: 105 mA @ 120 Vac (RIB01P) 105 mA @ 208-277 Vac (RIB02P)
Coil Voltage Input: RIB01P 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac
RIB02P 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac
49

RELAYS

20 AMP POWER CONTROL RELAYS

RIB347P
Power Relay, 20 Amp DPDT, 347 Vac Coil,
NEMA 1 Housing

RIB04P
Power Relay, 20 Amp DPDT, 480 Vac Coil,
NEMA 1 Housing

Blu N/C

Wht/Org

347 Vac

Yel

C

Org N/O
Gry N/C

Wht/Org

Prp

347 Vac

C

Brn N/O

Blu N/C

Wht/Grn

480 Vac

Yel

C

Org N/O
Gry N/C

Wht/Grn

Prp

480 Vac

C

Brn N/O

SPECIFICATIONS

DRY CONTACT INPUT RELAY

# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS (Both Models) UL864, California State Fire Marshal (RIB04P) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac 15 Amp Resistive @ 600 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

20 AMP POWER CONTROL RELAYS

RIB013P
Power Relay, 20 Amp, 3PST-N/O,
120 Vac Coil, NEMA 1 Housing

RIB023P
Power Relay, 20 Amp, 3PST-N/O,
208-277 Vac Coil, NEMA 1 Housing

Wht/Blk 120 Vac
Wht/Blk 120 Vac

Blu - N/O Blu - N/O
Yel - N/O Yel - N/O
Org - N/O Org - N/O

Wht/Brn 208-277 Vac
Wht/Brn 208-277 Vac

Blu - N/O Blu - N/O
Yel - N/O Yel - N/O
Org - N/O Org - N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1,158 VA Pilot Duty @ 240 Vac, 1 Phase 1,110 VA Pilot Duty @ 277 Vac, 1 Phase 1,640 VA Pilot Duty @ 480 Vac, 1 Phase 1,466 VA Pilot Duty @ 240 Vac, 3 Phase 2,112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

Coil Current: 105 mA @ 347 Vac (RIB347P) 105 mA @ 480 Vac (RIB04P) Coil Voltage Input: RIB347P 347 Vac ; 50-60 Hz Drop Out = 70 Vac Pull In = 295 Vac RIB04P 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac
Coil Current: 154 mA @ 120 Vac (RIB013P) 187 mA @ 208-277 Vac (RIB023P) Coil Voltage Input: RIB013P 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac RIB023P 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number

50

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

20 AMP POWER CONTROL RELAYS

RIB043P
Power Relay, 20 Amp 3PST-N/O, 480 Vac Coil,
NEMA 1 Housing

RIB243P
Power Relay, 20 Amp 3PST-N/O, 24 Vac/dc
Coil, NEMA 1 Housing

Wht/Grn 480 Vac
Wht/Grn 480 Vac

Blu - N/O Blu - N/O
Yel - N/O Yel - N/O
Org - N/O Org - N/O

Wht/Yel 24 Vac/dc
Wht/Yel 24 Vac/dc

Blu - N/O Blu - N/O
Yel - N/O Yel - N/O
Org - N/O Org - N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS (Both Models) UL864, California State Fire Marshal (RIB043P) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1,158 VA Pilot Duty @ 240 Vac, 1 Phase 1,110 VA Pilot Duty @ 277 Vac, 1 Phase 1,640 VA Pilot Duty @ 480 Vac, 1 Phase 1,466 VA Pilot Duty @ 240 Vac, 3 Phase 2,112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

30 AMP POWER CONTROL RELAY
RIB24Z
Power Relay, 30 Amp SPST-N/O + SPST-N/C, 24 Vac/dc Coil, NEMA 1 Housing

Wht/Yel

Blu

24 Vac/dc

N/C

Blu N/C

Org N/O

Wht/Yel 24 Vac/dc

Org N/O

Coil Current: 132 mA @ 480 Vac (RIB043P) 210 mA @ 24 Vac (RIB243P) 154 mA @ 30 Vdc (RIB243P)
Coil Voltage Input: RIB043P 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac
RIB243P 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc
Notes: · Order Normally Closed by adding "-NC" to end of model number

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST-N/O + SPST-N/C Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390 x 3.310 x 1.810 with .50 NPT Nipple Housing Detail: See Housing B in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

(800) 888-5538 | www.functionaldevices.com

51

RELAYS

20 AMP POWER CONTROL RELAYS

RIB12P
Power Relay, 20 Amp DPDT, 12 Vac/dc Coil,
NEMA 1 Housing

RIB12P30
Power Relay, 30 Amp DPDT, 12 Vac/dc Coil,
NEMA 1 Housing

Blu N/C

Wht/Yel

12 Vac/dc

Yel

C

Org N/O

Gry N/C

Wht/Yel

Prp

12 Vac/dc

C

Brn N/O

Blu N/C

Wht/Yel

Yel

12 Vac/dc

C

Org N/O

Gry N/C

Wht/Yel

Prp

12 Vac/dc

C

Brn N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.390H x 3.310W x 1.810D with .50 NPT Nipple (RIB12P) 2.390H x 3.310W x 1.810D with .75 NPT Nipple (RIB12P30) Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: (RIB12P) 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

Contact Ratings: (RIB12P30) 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

Coil Current: 115 mA @ 10 Vac 180 mA @ 12 Vac 79 mA @ 11 Vdc 90 mA @ 12 Vdc 115 mA @ 15 Vdc
Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 4.5 Vac / 4.8 Vdc Pull In = 9.7 Vac / 11 Vdc

20 / 30 AMP POWER CONTROL RELAYS

RIB24P
Power Relay, 20 Amp DPDT, 24 Vac/dc Coil,
NEMA 1 Housing

RIB24P30
Power Relay, 30 Amp DPDT, 24 Vac/dc Coil,
NEMA 1 Housing

Blu N/C

Wht/Yel

24 Vac/dc

Yel

C

Org N/O

Gry N/C

Wht/Yel

Prp

24 Vac/dc

C

Brn N/O

Blu N/C

Wht/Yel

Yel

24 Vac/dc

C

Org N/O

Gry N/C

Wht/Yel

Prp

24 Vac/dc

C

Brn N/O

SPECIFICATIONS

# Relays & Contact Type: One (1) DPDT Continuous Duty Coil

Contact Ratings: (RIB24P)

Expected Relay Life: 10 million cycles minimum mechanical

20 Amp Resistive @ 300 Vac

Operating Temperature: -30 to 140° F

20 Amp Resistive @ 28 Vdc

Humidity Range: 5 to 95% (noncondensing)

20 Amp Ballast @ 277-480 Vac

Operate Time: 18ms

Not rated for Electronic Ballast

Relay Status: LED On = Activated

15 Amp Resistive @ 600 Vac

Dimensions: 2.390 x 3.310 x 1.810 with .50 NPT Nipple 770 VA Pilot Duty @ 120 Vac

Housing Detail: See Housing B in housing guide for dimensions 1,158 VA Pilot Duty @ 240 Vac

Origin: Made of US and non-US parts

1,109 VA Pilot Duty @ 277 Vac

Wires: 16, 600V Rated

1,640 VA Pilot Duty @ 480 Vac

Approvals: UL Listed, UL916, UL864, UL60947, C-UL

Heavy Pilot Duty @ 600 Vac

California State Fire Marshal, CE, RoHS

3 HP @ 480-600 Vac

Housing Rating: UL Accepted for Use in Plenum, NEMA 1

2 HP @ 240-277 Vac

Gold Flash: Yes

1 HP @ 120 Vac

Override Switch: No

Contact Ratings: (RIB24P30) 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

52

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

30 AMP POWER CONTROL RELAYS

RIB01P30
Power Relay, 30 Amp DPST-N/O, 120 Vac Coil,
NEMA 1 Housing

RIB01P30-S
Power Relay, 30 Amp DPST-N/O + Coil Side
Override, 120 Vac Coil, NEMA 1 Housing

Org

Org

N/O

N/O

Wht/Blk 120 Vac

Pole 1

Wht/Blk 120 Vac Continuous

HAND

Org

N/O

Wht/Red

OFF

Org N/O

120 Vac

Control AUTO

Brn

Brn

N/O

N/O

Wht/Blk 120 Vac

Pole 2

Wht/Yel

Brn

Neutral

Brn

N/O

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No (RIB01P30) Coil Side (RIB01P30-S)

Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

30 AMP POWER CONTROL RELAY
RIB02P30
Power Relay, 30 Amp DPST-N/O, 208-277 Vac Coil, NEMA 1 Housing

Wht/Brn 208-277 Vac
Wht/Brn 208-277 Vac

Org N/O
Pole 1 Org N/O
Brn N/O
Pole 2 Brn N/O

Coil Current: 105 mA @ 120 Vac
Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac
Control Input: Wht/Blk = 120 Vac Continuous Wht/Red = 120 Vac Control Wht/Yel = Neutral
Notes: · Order Both Poles Normally Closed by adding "-NC" to end of model number
· Order Pole 1 Normally Open and Pole 2 Normally Closed by adding "-NONC" to end of model number

SPECIFICATIONS
# Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

(800) 888-5538 | www.functionaldevices.com

Coil Current: 105 mA @ 208-277 Vac
Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac
Notes: · Order Both Poles Normally Closed by adding "-NC" to end of model number · Order Pole 1 Normally Open and Pole 2 Normally Closed by adding "-NONC" to end of model number
53

RELAYS

20 AMP POWER CONTROL RELAYS

RIBT24B
Power Relay, 20 Amp SPDT, 24 Vac/dc Coil,
Hi/Lo Voltage Separation, NEMA 1 Housing

RIBT24SB
Power Relay, 20 Amp SPST + Override, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Blu

24 Vac/dc

N/C

Yel C

Org

Comm

N/O

24 Vac/dc Comm

Selectable Jumper Wire Org

CLOSED

Org

OPEN

AUTO

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBT24B) One (1) SPST Continuous Duty Coil (RIBT24SB)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple
Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No
Override Switch: No (RIBT24B) Yes (RIBT24SB)
20 AMP POWER CONTROL RELAYS

Contact Ratings: (RIBT24B) 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Coil Current: 45 mA @ 18 Vac 75 mA @ 24 Vac 30 mA @ 22 Vdc 32 mA @ 24 Vdc 42 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

RIBT2401B
Power Relay, 20 Amp SPDT, 24 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

RIBT2402B
Power Relay, 20 Amp SPDT, 24 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Contact Ratings: (RIBT24SB) 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Notes: · Normally Open or Normally Closed selected by yellow jumper wire (RIBT24SB)

Blu

120 Vac

N/C

Yel

24 Vac/dc

C

Org

Comm

N/O

Blu

208-277 Vac

N/C

Yel

24 Vac/dc

C

Org

Comm

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401B) 69 mA @ 208-277 Vac (RIBT2402B) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

54

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

20 AMP POWER CONTROL RELAYS

RIBT2401SB
Power Relay, 20 Amp SPST + Override, 24 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

RIBT2402SB
Power Relay, 20 Amp SPST + Override, 24 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Selectable Jumper Wire

Selectable Jumper Wire

120 Vac

Org

208-277 Vac

Org

24 Vac/dc Comm

CLOSED

Org

OPEN

AUTO

24 Vac/dc Comm

CLOSED

Org

OPEN

AUTO

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS (RIBT2401SB) UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS (RIBT2402SB) Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401SB) 69 mA @ 208-277 Vac (RIBT2402SB) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Notes: · Normally Open or Normally Closed selected by yellow jumper wire

20 AMP POWER CONTROL RELAYS

RIBT2401SBC
Power Relay, 20 Amp SPDT + Override, 24 Vac/dc/120 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

RIBT2402SBC
Power Relay, 20 Amp SPDT + Override, 24 Vac/dc/208-277 Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

120 Vac

208-277 Vac

24 Vac/dc

24 Vac/dc

Comm

Comm

Yel MANUAL C
AUTO

Blu

N/C - CLOSED

N/C

OPEN

Org

N/O - CLOSED

N/O

Yel MANUAL C
AUTO

Blu

N/C - CLOSED

N/C

OPEN

Org

N/O - CLOSED

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2)

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401SBC) 69 mA @ 208-277 Vac (RIBT2402SBC) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

(800) 888-5538 | www.functionaldevices.com

55

RELAYS

20 AMP TIME DELAY RELAY
RIBTD2401B
Time Delay Power Relay, 20 Amp SPDT, 24 Vac/dc/120 Vac Coil, NEMA 1 Housing

Blu

120 Vac

N/C

Yel

24 Vac/dc

C

Org

Comm

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms after time delay Relay Status: RED LED On = Activated
Time Delay Status: PINK LED FLASHING = Timing Timing Mode: Delay On Make (N/O) Timing Range: 6 seconds - 20 minutes
Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range
Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5%
Timing Repeatability: +1% Temperature Timing Variance: +1%
Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.000H x 4.000W x 1.810D with .50 NPT nipple
Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts
Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1
Gold Flash: No Override Switch: No

Contact Ratings:

Input Current:

20 Amp Resistive @ 277 Vac

133 mA @ 24 Vac

20 Amp Ballast @ 277 Vac

45 mA @ 24 Vdc

16 Amp Electronic Ballast @ 277 Vac (N/O) 51 mA @ 120 Vac

10 Amp Tungsten @ 120 Vac (N/O)

770 VA Pilot Duty @ 120 Vac

1,110 VA Pilot Duty @ 277 Vac

2 HP @ 277 Vac

1 HP @ 120 Vac

Timing Adjustment

Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

C BD
AE

Range Selection 1234
Only Close 1 Switch

Depressed for closed
Depressed for open

Switch Ranges 6s-20s 22s-1min15s 1min30s-5min 6min-20min

TIMING TABLE

Close Dip Switch A

Potentiometer Setting

B

C

D

1

6s

9s

13s

16s

2

22s

36s

50s

1min4s

3

1min30s 2min10s 3min20s 4min16s

4

6min

9min

13min20s 17min20s

E 20s 1min15s 5min 20min

Time Delay Application Example #1
Load 2 stays ON selected amount of time after Load 1 turns ON (N/C) Load 2 stays OFF selected amount of time after Load 1 turns ON (N/O)

Load 1
(Thermostat
Controlled Heater,
for example)

120 Vac Blu

Time Delay Application Example #2 (Requires an Inverting Relay)
Load 2 stays ON selected amount of time after Load 1 turns OFF (N/C) Load 2 stays OFF selected amount of time after Load 1 turns OFF (N/O)
120 Vac Hot

Load 1

(Thermostat

Blu

Controlled Heater,

for example)

Blu

Load 2

(Circulating Fan,

for example)

Load 1 Voltage Load 2 on N/O Contact Load 2 on N/C Contact

Yel RIBTD2401B
Time Delay Time Delay

Load 2
(Circulating Fan, for example)
Present
Absent ON OFF ON
OFF

Yel

Yel

RIB®
Select RIB® with coil input appropriate to sense Load 1.

RIBTD2401B Neutral

Load 1 Voltage Load 2 on N/O Contact Load 2 on N/C Contact

Time Delay Time Delay

Present
Absent ON
OFF ON
OFF

56

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

20 AMP POWER CONTROL RELAYS

RIBT242B
Power Relays, 20 Amp 2 SPDT, 24 Vac/dc Coil,
Hi/Lo Voltage Separation, NEMA 1 Housing

RIBT243B
Power Relays, 20 Amp 2 SPST-N/O + 1 SPDT, 24 Vac/dc Vac Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

RELAY 2 24 Vac/dc

Gry - N/C Prp - C

RELAY 1 24 Vac/dc

Brn - N/O Blu - N/C

Comm

Yel - C

Org - N/O

All relay coils use the same common

RELAY 3 24 Vac/dc

Gry - N/C Prp - C

RELAY 2 24 Vac/dc

Brn - N/O Yel - N/O

RELAY 1 24 Vac/dc

Yel - N/O Blu - N/O

Comm

Blu - N/O

All relay coils use the same common

SPECIFICATIONS
# Relays & Contact Type: Two (2) SPDT Continuous Duty Coil (RIBT242B) Two (2) SPST + One (1) SPDT Continuous Duty Coil (RIBT243B)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.800D with .50 NPT Nipple
Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
Approvals: UL Listed, C-UL, CE, RoHS (Both Models) UL916 (RIBT243B) UL864 , California State Fire Marshal (RIBT242B)
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No
Override Switch: No
20 AMP POWER CONTROL RELAY
RIBT24P
Power Relay, 20 Amp DPDT, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

24 Vac/dc Comm

Blu - N/C Yel - C
Org - N/O Gry - N/C
Prp - C Brn - N/O

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Notes: · RIBT243B not rated for UL864

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.800D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

(800) 888-5538 | www.functionaldevices.com

Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc
57

30 AMP POWER CONTROL RELAY
RIBT24Z
Power Relay, 30 Amp SPST-N/O + SPST-N/C, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

RELAYS

24 Vac/dc Comm

Blu - N/C Blu - N/C
Org - N/O Org - N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST-N/O + One (1) SPST-N/C Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.800D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

20 AMP POWER CONTROL RELAY
RIBT243P
Power Relay, 20 Amp 3PST-N/O, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

24 Vac/dc Comm

Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.000H x 4.000W x 1.800D with .50 NPT Nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1,158 VA Pilot Duty @ 240 Vac, 1 Phase 1,110 VA Pilot Duty @ 277 Vac, 1 Phase 1,640 VA Pilot Duty @ 480 Vac, 1 Phase 1,466 VA Pilot Duty @ 240 Vac, 3 Phase 2,112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc
Notes: · Order Normally Closed by adding "-NC" to end of model number

58

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

20 AMP TRACK MOUNT CONTROL RELAYS

RIBM2401B
Power Relay, 20 Amp SPDT,
24 Vac/dc/120 Vac Coil, 4.00" Track Mount

RIBM2402B
Power Relay, 20 Amp SPDT,
24 Vac/dc/208-277 Vac Coil, 4.00" Track Mount

C Comm
N/O 24 Vac/dc
120 Vac N/C

C Comm
N/O 24 Vac/dc
208-277 Vac N/C

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.250H x 4.000W x 0.880"D1/1.380"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

20 AMP TRACK MOUNT CONTROL RELAYS

RIBM2401SB
Power Relay, 20 Amp SPST + Override,
24 Vac/dc/120 Vac Coil, 4.00" Track Mount

RIBM2402SB
Power Relay, 20 Amp SPST + Override,
24 Vac/dc/208-277 Vac Coil, 4.00" Track Mount

Comm

Selectable Jumper Wire

Comm

Selectable Jumper Wire

24 Vac/dc 120 Vac

CLOSED OPEN AUTO

Not Used

24 Vac/dc 208-277 Vac

CLOSED OPEN AUTO

Not Used

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBM2401B) 69 mA @ 208-277 Vac (RIBM2402B) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

SPECIFICATIONS

# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.60"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Notes: · Normally Open or Normally Closed selected by yellow jumper wire

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBM2401B) 69 mA @ 208-277 Vac (RIBM2402B) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

(800) 888-5538 | www.functionaldevices.com

59

20 AMP TRACK MOUNT CONTROL RELAYS

RIBM2401SBC
Power Relay, 20 Amp SPDT + Override,
24 Vac/dc/120 Vac Coil, 4.00" Track Mount

RIBM2402SBC
Power Relay, 20 Amp SPDT + Override,
24 Vac/dc/208-277 Vac Coil, 4.00" Track Mount

RELAYS

Comm

24 Vac/dc

120 Vac

AUTO C
MANUAL

N/C

N/O

CLOSED CLOSED

N/O

OPEN

N/C

Comm

24 Vac/dc

208-277 Vac

AUTO C
MANUAL

N/C

N/O

CLOSED CLOSED

N/O

OPEN

N/C

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.40"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes (2)
30 AMP TRACK MOUNT CONTROL RELAY
RIBM24ZN
Power Relay, 30 Amp DPDT, 24 Vac/dc Coil, 4.00" Track Mount

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBM2401SBC) 69 mA @ 208-277 Vac (RIBM2402SBC) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

N/C
24 Vac/dc N/O C
N/C Comm
N/O C

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.38"H x 4.00"W x 1.50"D1/2.00"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: Yes Override Switch: No

Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac NEMA B600 Pilot Duty

60

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

Coil Current: 110 mA @ 20 Vac 125 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 70 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

RELAYS

30 AMP TRACK MOUNT CONTROL RELAYS

RIBM24ZL
Power Relay, 30 Amp DPST-N/O,
24 Vac/dc Coil, 4.00" Track Mount

RIBMN24ZL
Power Relay, 30 Amp DPST-N/O,
24 Vac/dc Coil, 2.75" Track Mount

C Comm
N/O C
24 Vac/dc N/O

C Comm
N/O C
24 Vac/dc N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.50"H x 4.00"W x 2.25"D1/2.75"D2 (RIBM24ZL) 2.50"H x 2.75"W x 2.25"D1/2.75"D2 (RIBMN24ZL) Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 (RIBM24ZL) or 2.750"(RIBMN24ZL) Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No
30 AMP TRACK MOUNT CONTROL RELAY
RIBM243PN
Power Relay, 30 Amp 3PDT, 24 Vac/dc Coil, 4.00" Track Mount

Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,109 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac

Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc
Notes: Order Normally Closed by adding "-NC" to end of model number

N/C

N/O C N/C

24 Vac/dc

N/O

C

N/C

Comm N/O
C

SPECIFICATIONS
# Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Housing Detail: See Housing H in housing guide for dimensions Dimensions: 2.38"H x 4.00"W x 1.50"D1/2.00"D2 Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: No Override Switch: No

Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase

(800) 888-5538 | www.functionaldevices.com

Coil Current: 190 mA @ 24 Vac 140 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc
61

RELAYS

30 AMP TRACK MOUNT CONTROL RELAY
RIBM013PN
Power Relay, 30 Amp 3PDT, 120 Vac Coil, 4.00" Track Mount

N/C

N/O C N/C

Comm

N/O

C

N/C Not Used

120 Vac N/O
C

SPECIFICATIONS
# Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.38"H x 4.00"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No
30 AMP TRACK MOUNT CONTROL RELAY
RIBM023PN
Power Relay, 30 Amp 3PDT, 208-277 Vac Coil, 4.00" Track Mount

Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase

N/C

N/O C N/C

Comm

N/O

C

N/C Not Used

208-277 Vac N/O
C

SPECIFICATIONS
# Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.38"H x 4.00"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No

Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase

62

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

Coil Current: 140 mA @ 120 Vac Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac
Coil Current: 170 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac

30 AMP TRACK MOUNT CONTROL RELAY
RIBM043PN
Power Relay, 30 Amp 3PDT, 480 Vac Coil, 4.00" Track Mount

RELAYS

N/C

N/O C N/C

Comm

N/O

C

Not Used

N/C

480 Vac N/O C

SPECIFICATIONS
# Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.38"H x 4.00"W x 1.38"D1/1.88"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No

Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase

30 AMP TRACK MOUNT CONTROL RELAY
RIBM043PN-HD
Heavy Duty Relay, 30 Amp 3PDT, 480 Vac Coil, For Use in More Transient Prone Environments, 4.00" x 3.25"Track Mount

Coil Current: 140 mA @ 120 Vac
Coil Voltage Input: 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac
Notes: See model RIBM043PN-HD for use in more transient prone environments

N/C

N/O C N/C

Comm

N/O

C

Not Used

N/C

480 Vac N/O C

SPECIFICATIONS
# Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 3.25"H x 4.00"W x 1.50"D1/2.00"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: 4.000 MT4 Mounting Track Sold Separately Origin: Made of US and non-US parts Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No

Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1,158 VA @ 240 Vac, 1 Phase 1,110 VA @ 277 Vac, 1 Phase 1,640 VA @ 480 Vac, 1 Phase 1,466 VA @ 240 Vac, 3 Phase 2,122 VA @ 480 Vac, 3 Phase

Coil Current: 140 mA @ 480 Vac
Coil Voltage Input: 480 Vac/dc ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac

(800) 888-5538 | www.functionaldevices.com

63

LATCHING RELAYS

RELAYS

RIBL24BM

RIBL24B

RIBL12SB

These relays are switched by pulse commands from an appropriate power source or a controller. The relay contacts are mechanically latched in position, so that the load remains in its last state (on or off) during a loss of power. A pulse of opposing polarity latches the relay in the alternate state.

Product Features
· Prepackaged for quick and easy installation
· Electromechanical relay · Mechanically latching · Status LED and auxiliary ouput
models available · Electronic ballast rating · 20 Amp rating

Typical Application

24 Vac Supply

Latch Unlatch

On Controller Comm
O

N/O Momentary Wall Switch

Local Power
120-277 Vac Lighting
Status to Controller
N/O Momentary Wall Switch

ENCLOSED LATCHING RELAYS

MODEL # RIBL12B

COIL VOLTAGE

AC/DC

RELAY CONTACTS

RESISTIVE

·

12

1 SPST 20 A @ 120-277 Vac

CONTACT RATINGS

MOTOR 3 HP @ 240 Vac

PILOT DUTY 720 VA @ 120-277 Vac

OVERRIDE SWITCH

AUXILIARY OUTPUT

HOUSING STYLE *
A

SPEC PAGE
65

RIBL12BM ·

12

1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac

720 VA @ 120-277 Vac

·

B

65

RIBL12SB

·

12

1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac

720 VA @ 120-277 Vac

·

A

65

RIBL12SBM ·

12

1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac

720 VA @ 120-277 Vac

·

·

B

65

RIBL24B

·

24

1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac

720 VA @ 120-277 Vac

A

66

RIBL24BM ·

24

1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac

720 VA @ 120-277 Vac

·

B

66

RIBL24SB

·

24

1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac

720 VA @ 120-277 Vac

·

A

66

RIBL24SBM ·

24

1 SPST 20 A @ 120-277 Vac 3 HP @ 240 Vac

720 VA @ 120-277 Vac

·

·

B

66

= UL Listed - see data sheet for specific Listing

* = See Housing Guide on page 201

64

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

LATCHING RELAY

RIBL12B
Mechanically Latching Relay, 20 Amp SPST, 12
Vac/dc Coil, NEMA 1 Housing

Wht/Blu 12 Vac/dc (­)
LATCH
Wht/Yel 12 Vac/dc (+)
Wht/Red 12 Vac/dc (­)
UNLATCH

Org Line
Org Load

RIBL12BM
Mechanically Latching Relay, 20 Amp SPST, 12 Vac/dc Coil, Status LED, Auxiliary Output, NEMA 1 Housing
Yel Line

Wht/Blu 12 Vac/dc (­)
LATCH

Org Load

Wht/Yel 12 Vac/dc (+)

Wht/Blk Load Neutral

Wht/Red 12 Vac/dc (­)
UNLATCH

Gry
AUXILIARY CONTACT
Gry

RIBL12B-RD · Red housing

RIBL12B-N4 · NEMA 4X housing

SPECIFICATIONS

# Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms
Maximum Pulse Length: 30 seconds Relay Status / Auxiliary: (RIBL12BM)
Contact Closed: LED On = Voltage Detected on Load Wire (RIBL12BM) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple (RIBL12B)
2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple (RIBL12BM) Housing Detail: See Housing A (RIBL12B) or Housing B (RIBL12BM)
in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No

Contact Ratings:

Coil Current:

20 Amp Resistive @ 120-277 Vac

182 mA @ 10 Vac

20 Amp Ballast @ 120-277 Vac

250 mA @ 12 Vac

16 Amp Electronic Ballast @ 120-277 Vac 165 mA @ 10 Vdc

5540 Watt Tungsten @ 277 Vac

198 mA @ 12 Vdc

720 VA Pilot Duty @ 120-277 Vac

250 mA @ 15 Vdc

2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac

Latch / Unlatch: Min. 10 Vdc / 11 Vac
Auxiliary Contact:

Notes:

3 Amp @ 30 Vac/dc max. (RIBL12BM)

· Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact.

· Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact.

· Voltage should not be applied to the coil for more than 30 seconds.

· Auxiliary contact and status LED activate when 120-277 Vac is applied between

 Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL12BM)

LATCHING RELAY

RIBL12SB
Mechanically Latching Relay, 20 Amp SPST + True Override, 12 Vac/dc Coil, NEMA 1 Housing

Wht/Blu 12 Vac/dc (­)
LATCH
Wht/Yel 12 Vac/dc (+)

Org Line
*

Wht/Red 12 Vac/dc (­)
UNLATCH

Org Load

* Mechanically latches and unlatches
with a coil input or by manual override

RIBL12SBM
Mechanically Latching Relay, 20 Amp SPST + True Override, 12 Vac/dc Coil, Status LED, Auxiliary Output, NEMA 1 Housing

Wht/Blu 12 Vac/dc (­)
LATCH
Wht/Yel 12 Vac/dc (+)

Yel Line
*
Org Load

Wht/Red 12 Vac/dc (­)
UNLATCH
* Mechanically latches and
unlatches with a coil input or by manual override

Wht/Blk Load Neutral
Gry
AUXILIARY CONTACT
Gry

RIBL12SB-RD · Red housing

SPECIFICATIONS

# Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms
Maximum Pulse Length: 30 seconds Relay Status / Auxiliary: (RIBL12SBM)
Contact Closed: LED On = Voltage Detected on Load Wire (RIBL12SBM) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple (RIBL12SB) 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple (RIBL12SBM)
Housing Detail: See Housing A (RIBL12SB) or Housing B (RIBL12SBM) in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes

Contact Ratings:

Coil Current:

20 Amp Resistive @ 120-277 Vac

182 mA @ 10 Vac

20 Amp Ballast @ 120-277 Vac

250 mA @ 12 Vac

16 Amp Electronic Ballast @ 120-277 Vac 165 mA @ 10 Vdc

5540 Watt Tungsten @ 277 Vac

198 mA @ 12 Vdc

720 VA Pilot Duty @ 120-277 Vac

250 mA @ 15 Vdc

2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac

Latch / Unlatch: Min. 10 Vdc / 11 Vac

Auxiliary Contact:

Notes:

3 Amp @ 30 Vac/dc max. (RIBL12SBM)

· Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact.

· Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact.

· Voltage should not be applied to the coil for more than 30 seconds.

· Auxiliary contact and status LED activate when 120-277 Vac is applied between

 Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL12SBM)

(800) 888-5538 | www.functionaldevices.com

65

RELAYS

LATCHING RELAYS

RIBL24B
Mechanically Latching Relay, 20 Amp SPST, 24
Vac/dc Coil, NEMA 1 Housing

RIBL24BM
Mechanically Latching Relay, 20 Amp SPST, 24 Vac/dc Coil, Status LED, Auxiliary Output, NEMA 1 Housing

Wht/Blu 24 Vac/dc (­)
LATCH Org
Wht/Yel 24 Vac/dc (+)
Org Wht/Red 24 Vac/dc (­) UNLATCH
SPECIFICATIONS

Wht/Blu 24 Vac/dc (­)
LATCH
Wht/Yel 24 Vac/dc (+)
Wht/Red 24 Vac/dc (­)
UNLATCH

Yel Line
Org Load
Wht/Blk Load Neutral
Gry
AUXILIARY CONTACT
Gry

RIBL24B-RD · Red housing

RIBL24B-N4 · NEMA 4X housing (Not available on switched models)

# Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms
Maximum Pulse Length: 30 seconds Relay Status / Auxiliary: (RIBL24BM)
Contact Closed: LED On = Voltage Detected on Load Wire (RIBL24BM) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple (RIBL24B) 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple (RIBL24BM)
Housing Detail: See Housing A (RIBL24B) or Housing B (RIBL24BM) in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No

Contact Ratings:

Coil Current:

20 Amp Resistive @ 120-277 Vac

175 mA @ 20 Vac

20 Amp Ballast @ 120-277 Vac

210 mA @ 24 Vac

16 Amp Electronic Ballast @ 120-277 Vac

92 mA @ 20 Vdc

5540 Watt Tungsten @ 277 Vac

110 mA @ 24 Vdc

720 VA Pilot Duty @ 120-277 Vac

138 mA @ 30 Vdc

2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac

Latch / Unlatch: Min. 20 Vdc / 22 Vac
Auxiliary Contact:

Notes:

3 Amp @ 30 Vac/dc max. (RIBL24BM)

· Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact.

· Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact.

· Voltage should not be applied to the coil for more than 30 seconds.

· Auxiliary contact and status LED activate when 120-277 Vac is applied between

 Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL24BM)

LATCHING RELAYS

RIBL24SB
Mechanically Latching Relay, 20 Amp SPST + True Override, 24 Vac/dc Coil, NEMA 1 Housing

Wht/Blu 24 Vac/dc (­)
LATCH
Wht/Yel 24 Vac/dc (+)

Org Line
*

Wht/Red 24 Vac/dc (­)
UNLATCH

Org Load

* Mechanically latches and unlatches
with a coil input or by manual override

RIBL24SBM
Mechanically Latching Relay, 20 Amp SPST + True Override, 24 Vac/dc Coil, Status LED, Auxiliary Output, NEMA 1 Housing

Wht/Blu 24 Vac/dc (­)
LATCH
Wht/Yel 24 Vac/dc (+)
Wht/Red 24 Vac/dc (­)
UNLATCH
* Mechanically latches and
unlatches with a coil input or by manual override

Yel Line
*
Org Load
Wht/Blk Load Neutral
Gry
AUXILIARY CONTACT
Gry

RIBL24SB-RD · Red housing

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms
Maximum Pulse Length: 30 seconds Relay Status / Auxiliary: (RIBL24SBM)
Contact Closed: LED On = Voltage Detected on Load Wire (RIBL24SBM) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple (RIBL24SB) 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple (RIBL24SBM)
Housing Detail: See Housing A (RIBL24SB) or Housing B (RIBL24SBM) in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes

Contact Ratings:

Coil Current:

20 Amp Resistive @ 120-277 Vac

175 mA @ 20 Vac

20 Amp Ballast @ 120-277 Vac

210 mA @ 24 Vac

16 Amp Electronic Ballast @ 120-277 Vac 92 mA @ 20 Vdc

5540 Watt Tungsten @ 277 Vac

110 mA @ 24 Vdc

720 VA Pilot Duty @ 120-277 Vac

138 mA @ 30 Vdc

2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac

Latch / Unlatch: Min. 20 Vdc / 22 Vac
Auxiliary Contact:

Notes:

3 Amp @ 30 Vac/dc max (RIBL24SBM).

· Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact.

· Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact.

· Voltage should not be applied to the coil for more than 30 seconds.

· Auxiliary contact and status LED activate when 120-277 Vac is applied between

 Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL24SBM)

66

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

LOW-INPUT / OPTOISOLATED RELAYS

RELAYS

RIBTE24B

RIBME2401B

RIBTE02P-S

Optoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from analog outputs.
Product Features
· Prepackaged for quick and easy installation · Extremely low current draw on the input · Control input can connect to AO for
relay control · Protect controller from feedback or
voltage transients

High Voltage 60 Hz ac

Controller
Analog or Digital Out

Power Supply

Relay

Opto Input

Opto RIB®

Load

Low Voltage

60 Hz ac

Controller 24 Vac/dc
Analog or Digital Out

Power Supply

Relay

Opto Input

Opto RIB®

Load

ENCLOSED LOW-INPUT / OPTOISOLATED RELAYS
CONTACT RATINGS

MODEL #

RIBTELC

·

RIBTELS

·

RIBTE24B

·

RIBTE01B

·

RIBTE02B

·

RIBTE24SB

·

RIBTE01SB

·

RIBTE02SB

·

RIBTE24P

·

RIBTE01P

·

RIBTE02P

·

RIBTE01P-S ·

RIBTE02P-S ·

CONTROL POWER

RELAY

HIGH/LOW OVERRIDE HOUSING SPEC

INPUT

INPUT CONTACTS RESISTIVE

MOTOR

PILOT DUTY SEPARATION SWITCH STYLE * PAGE

5-25 Vac/dc 10-30 Vac/dc 1 SPDT 10 A @ 120-277 Vac 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac

·

C

68

5-25 Vac/dc 10-30 Vac/dc 1 SPST 10 A @ 120-277 Vac 1/3 HP @ 120-240 Vac (N/O) 480 VA @ 240-277 Vac

·

1

C

68

5-25 Vac/dc 24 Vac/dc

1 SPDT

20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

C

68

5-25 Vac/dc 120 Vac

1 SPDT

20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

C

69

5-25 Vac/dc 208-277 Vac 1 SPDT

20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

C

69

5-25 Vac/dc 24 Vac/dc

1 SPST

20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

1

C

70

5-25 Vac/dc 120 Vac

1 SPST

20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

1

C

70

5-25 Vac/dc 208-277 Vac 1 SPST

20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

1

C

71

5-25 Vac/dc 24 Vac/dc

1 DPDT

20 A @ 300 Vac

3 HP @ 480-600 Vac

1,640 VA @ 480 Vac

·

C

71

5-25 Vac/dc 120 Vac

1 DPDT

20 A @ 300 Vac

3 HP @ 480-600 Vac

1,640 VA @ 480 Vac

·

C

72

5-25 Vac/dc 208-277 Vac 1 DPDT

20 A @ 300 Vac

3 HP @ 480-600 Vac

1,640 VA @ 480 Vac

·

C

72

5-25 Vac/dc 120 Vac

1 DPDT

20 A @ 300 Vac

3 HP @ 480-600 Vac

1,640 VA @ 480 Vac

·

1 #

C

73

5-25 Vac/dc 208-277 Vac 1 DPDT

20 A @ 300 Vac

3 HP @ 480-600 Vac

1,640 VA @ 480 Vac

·

1 #

C

73

TRACK MOUNT LOW-INPUT / OPTOISOLATED RELAYS
CONTACT RATINGS

CONTROL

POWER

RELAY

MODEL #

INPUT

INPUT

CONTACTS RESISTIVE

RIBME2401B · 5-25 Vac/dc

24 Vac/dc/120 Vac

1 SPDT

20 A @ 277 Vac

RIBME2402B · 5-25 Vac/dc 24 Vac/dc/208-277 Vac 1 SPDT

20 A @ 277 Vac

MOTOR 2 HP @ 277 Vac 2 HP @ 277 Vac

PILOT DUTY

OVERRIDE TRACK

SPEC

SWITCH MOUNT ^ PAGE

1,110 VA @ 277 Vac

MT4 Series

73

1,110 VA @ 277 Vac

MT4 Series

73

= UL Listed - see data sheet for specific Listing

* = See Housing Guide on page 201

^ = Track mount sold separately # = Coil side relay override (requires unit to be powered)

(800) 888-5538 | www.functionaldevices.com

67

RELAYS

LOW COIL INPUT RELAYS

RIBTELC
Low Input/Optoisolated Relay, 10 Amp SPDT,
10-30 Vac/dc Power Input, 5-25 Vac/dc Control
Input, Hi/Lo Voltage Separation, NEMA 1 Housing

RIBTELS
Low Input/Optoisolated Relay, 10 Amp SPST + Override,
10-30 Vac/dc Power Input, 5-25 Vac/dc Control Input,
Hi/Lo Voltage Separation, NEMA 1 Housing

5-25 Vac/dc CONTROL INPUT
10-30 Vac/dc POWER INPUT

Blu - N/C Yel - C
Org - N/O

5-25 Vac/dc CONTROL INPUT
10-30 Vac/dc POWER INPUT

Selectable Jumper Wire

Org

CLOSED

Org

OPEN

AUTO

SPECIFICATIONS
Power Input: 10-30 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms
Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes (RIBTELC), No (RIBTELS) Override Switch: No (RIBTELC), Yes (RIBTELS)

Contact Ratings: 10 Amp Resistive @ 120-277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

LOW COIL INPUT RELAY
RIBTE24B
Low Input/Optoisolated Relay, 20 Amp SPDT, 24 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing

Power Input Ratings: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

Notes: · Normally Open or Normally Closed selected by yellow jumper wire (RIBTELS)

24 Vac/dc POWER INPUT
5-25 Vac/dc CONTROL INPUT

Blu - N/C Yel - C
Org - N/O

SPECIFICATIONS
Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

68

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

LOW COIL INPUT RELAY
RIBTE01B
Low Input/Optoisolated Relay, 20 Amp SPDT, 120 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing

5-25 Vac/dc CONTROL INPUT
Wht/Blk 120 Vac
POWER INPUT Wht/Blk

Blu - N/C Yel - C
Org - N/O

SPECIFICATIONS
Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings:

Power Input Ratings:

20 Amp Resistive @ 277 Vac

47 mA @ 120 Vac

5 Amp Resistive @ 480 Vac

1110 VA Pilot Duty @ 277 Vac

770 VA Pilot Duty @ 120 Vac

20 Amp Ballast @ 277 Vac

16 Amp Electronic Ballast @ 277 Vac (N/O)

10 Amp Tungsten @ 120 Vac (N/O)

240 Watt Tungsten @ 120 Vac (N/C)

2 HP @ 277 Vac

1 HP @ 120 Vac

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

LOW COIL INPUT RELAY
RIBTE02B
Low Input/Optoisolated Relay, 20 Amp SPDT, 208-277 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing

5-25 Vac/dc CONTROL INPUT
Wht/Brn 208-277 Vac POWER INPUT Wht/Brn

Blu - N/C Yel - C
Org - N/O

SPECIFICATIONS
Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings:

Power Input Ratings:

20 Amp Resistive @ 277 Vac

69 mA @ 208-277 Vac

5 Amp Resistive @ 480 Vac

1110 VA Pilot Duty @ 277 Vac

770 VA Pilot Duty @ 120 Vac

20 Amp Ballast @ 277 Vac

16 Amp Electronic Ballast @ 277 Vac (N/O)

10 Amp Tungsten @ 120 Vac (N/O)

240 Watt Tungsten @ 120 Vac (N/C)

2 HP @ 277 Vac

1 HP @ 120 Vac

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

(800) 888-5538 | www.functionaldevices.com

69

RELAYS

LOW COIL INPUT RELAY
RIBTE24SB
Low Input/Optoisolated Relay, 20 Amp SPST + Override, 24 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing

24 Vac/dc POWER INPUT

Selectable Jumper Wire Org

5-25 Vac/dc CONTROL INPUT

CLOSED Org OPEN AUTO

SPECIFICATIONS
Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes

Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

Notes: · Normally Open or Normally Closed selected by yellow jumper wire

LOW COIL INPUT RELAY
RIBTE01SB
Low Input/Optoisolated Relay, 20 Amp SPST + Override, 120 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing

Wht/Blk
120 Vac POWER INPUT
Wht/Blk

Selectable Jumper Wire Org

5-25 Vac/dc CONTROL INPUT

CLOSED

Org

OPEN

AUTO

SPECIFICATIONS

Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes

Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

Power Input Ratings: 47 mA @ 120 Vac
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

Notes: · Normally Open or Normally Closed selected by yellow jumper wire

70

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

LOW COIL INPUT RELAY
RIBTE02SB
Low Input/Optoisolated Relay, 20 Amp SPST + Override, 208-277 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing

Wht/Brn 208-277 Vac POWER INPUT Wht/Brn
5-25 Vac/dc CONTROL INPUT

Selectable Jumper Wire Org

CLOSED

Org

OPEN

AUTO

SPECIFICATIONS
Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes

Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

Power Input Ratings: 69 mA @ 208-277 Vac

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

Notes: · Normally Open or Normally Closed selected by yellow jumper wire

LOW COIL INPUT RELAY
RIBTE24P
Low Input/Optoisolated Relay, 20 Amp DPDT, 24 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing

24 Vac/dc POWER INPUT
5-25 Vac/dc CONTROL INPUT

Blu - N/C Yel - C
Org - N/O Gry - N/C
Prp - C Brn - N/O

SPECIFICATIONS
Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple
Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

Power Input Ratings: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

(800) 888-5538 | www.functionaldevices.com

71

RELAYS

LOW COIL INPUT RELAY
RIBTE01P
Low Input/Optoisolated Relay, 20 Amp DPDT, 120 Vac/dc Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing

Wht/Blk 120 Vac
POWER INPUT Wht/Blk
5-25 Vac/dc CONTROL INPUT

Blu - N/C Yel - C
Org - N/O Gry - N/C
Prp - C Brn - N/O

SPECIFICATIONS
Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

Power Input Ratings: 105 mA @ 120 Vac

LOW COIL INPUT RELAY
RIBTE02P
Low Input/Optoisolated Relay, 20 Amp DPDT, 208-277 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo Voltage Separation, NEMA 1 Housing

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

Wht/Brn 208-277 Vac POWER INPUT
Wht/Brn
5-25 Vac/dc CONTROL INPUT

Blu - N/C Yel - C
Org - N/O Gry - N/C
Prp - C Brn - N/O

SPECIFICATIONS
Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

Power Input Ratings: 105 mA @ 208-277 Vac

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

72

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

LOW COIL INPUT RELAYS

RIBTE01P-S
Low Input/Optoisolated Relay, 20 Amp DPDT +
Override, 120 Vac Power Input, 5-25 Vac/dc Control
Input, Hi/Lo Voltage Separation, NEMA 1 Housing

RIBTE02P-S
Low Input/Optoisolated Relay, 20 Amp DPDT + Override,
208-277 Vac Power Input, 5-25 Vac/dc Control Input, Hi/Lo
Voltage Separation, NEMA 1 Housing

Wht/Blk
120 Vac POWER INPUT
COIL ON COIL OFF
AUTO
Wht/Blk

Blu - N/C Yel - C
Org - N/O Gry - N/C

Wht/Brn
208-277 Vac POWER INPUT
COIL ON COIL OFF
AUTO
Wht/Brn

Blu - N/C Yel - C
Org - N/O Gry - N/C

5-25 Vac/dc CONTROL INPUT

Prp - C Brn - N/O

5-25 Vac/dc CONTROL INPUT

Prp - C Brn - N/O

SPECIFICATIONS
Power Input: 120 Vac, 50-60 Hz (RIBTE01P-S) 208-277 Vac, 50-60 Hz (RIBTE02P-S)
Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple
Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
Approvals: UL Listed, UL916, C-UL,CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1
Gold Flash: Yes Override Switch: Yes*

Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

Notes: · Override capability is made possible by supplying constant voltage on the Power Input. No Control Input Voltage is necessary to override the relay. *

Power Input Ratings: 105 mA @ 120 Vac (RIBTE01P-S) 105 mA @ 208-277 Vac (RIBTE02P-S)

LOW COIL INPUT TRACK OUNT RELAYS

RIBME2401B
Low Input/Optoisolated Relay, 20 Amp SPDT, 24
Vac/dc/120 Vac Power Input, 5-25 Vac/dc Control
Input, 4.00" Track Mount

RIBME2402B
Low Input/Optoisolated Relay, 20 Amp SPDT, 24
Vac/dc/208-277 Vac Power Input, 5-25 Vac/dc
Control Input, 4.00" Track Mount

5-25 Vac/dc CONTROL INPUT

5-25 Vac/dc CONTROL INPUT

C

C

Comm

N/O

Comm

N/O

24 Vac/dc

24 Vac/dc N/C

N/C

POWER INPUTS

POWER INPUTS

120 Vac

208-277 Vac

SPECIFICATIONS

Power Input: 24 Vac/dc/120 Vac, 50-60 Hz (RIBME2401B) 24 Vac/dc/208-277 Vac, 50-60 Hz (RIBME2402B)
Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.75"H x 4.00"W x 0.88"D1/1.38"D2
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No
Override Switch: No

Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBME2401B) 69 mA @ 208-277 Vac (RIBME2402B)

33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc

Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized)

(800) 888-5538 | www.functionaldevices.com

73

POLARIZED / ALARM RELAYS

RIB24P-FA

RIBT24B-FA

RELAYS

RIB12S-FA

RIBMN12S-FA

RIB24C-FA-RD

These relays are polarized to work in a supervised system and may be turned on and off by reversing polarity. These prepackaged relays make installation quick and easy and can be used in fire alarm systems, smoke control systems, etc.

Product Features
· Coil input is polarity sensitive · For use with fire alarm systems · System supervision for controllers that utilize
end-of-line resistors · Four wire circuit ensures indication of broken
wiring connection with RIB® · Prepackaged for quick and easy installation

Typical Application

Load

Load

RIB24C-FA Coil
+­

RIB24C-FA Coil
+­

Controller

Signaling Circuit

End-ofLine
Resistor

ENCLOSED POLARIZED / ALARM RELAYS

CONTACT RATINGS

MODEL #
RIB12C-FA ·

COIL VOLTAGE
12 Vac/dc

RELAY CONTACTS
1 SPDT

RESISTIVE 10 A @ 277 Vac

MOTOR 1 HP @ 250 Vac

PILOT DUTY 770 VA @ 250 Vac

HIGH/LOW OVERRIDE HOUSING SEPARATION SWITCH STYLE *
A

SPEC PAGE
75

RIB24C-FA ·

24 Vac/dc

1 SPDT

10 A @ 277 Vac

1 HP @ 250 Vac

770 VA @ 250 Vac

A

75

RIB12S-FA ·

12 Vac/dc

1 SPST

10 A @ 277 Vac

1 HP @ 250 Vac

770 VA @ 250 Vac

1

A

75

RIB24S-FA ·

24 Vac/dc

1 SPST

10 A @ 277 Vac

1 HP @ 250 Vac

770 VA @ 250 Vac

1

A

75

RIBT24B-FA ·

24 Vac/dc

1 SPDT

20 A @ 277 Vac

2 HP @ 277 Vac

1,110 VA @ 277 Vac

·

C

76

RIB24P-FA ·

24 Vac/dc

1 DPDT

20 A @ 300 Vac 3 HP @ 480-600 Vac

1,640 VA @ 480 Vac

B

76

TRACK MOUNT POLARIZED / ALARM RELAYS

CONTACT RATINGS

MODEL #
RIBMN12C-FA ·

COIL VOLTAGE
12 Vac/dc

RELAY CONTACTS
1 SPDT

RESISTIVE 15 A @ 125 Vac

MOTOR 1 HP @ 250 Vac

PILOT DUTY 770 VA @ 250 Vac

OVERRIDE SWITCH

TRACK MOUNT ^
MT212 Series

SPEC PAGE
77

RIBMN24C-FA ·

24 Vac/dc

1 SPDT

15 A @ 125 Vac

1 HP @ 250 Vac

770 VA @ 250 Vac

MT212 Series

77

RIBMN12S-FA ·

12 Vac/dc

1 SPST

15 A @ 125 Vac

1 HP @ 250 Vac

770 VA @ 250 Vac

1

MT212 Series

77

RIBMN24S-FA ·

24 Vac/dc

1 SPST

15 A @ 125 Vac

1 HP @ 250 Vac

770 VA @ 250 Vac

1

MT212 Series

77

= UL Listed - see data sheet for specific Listing

* = See Housing Guide on page 201

^ = Track mount sold separately

74

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

FIRE ALARM RELAYS
RIB12C-FA
Polarized Relay, 10 Amp SPDT, 12 Vac/dc Coil, NEMA 1 Housing

RIB12S-FA
Polarized Relay 10 Amp SPST-N/O + Override, 12
Vac/dc Coil, NEMA 1 Housing

RELAYS

2nd Wht/Blu 12 Vac/dc

2nd Wht/Blu 12 Vac/dc

Wht/Blu

+

Blu

Wht/Blu

+

12 Vac/dc

N/C

12 Vac/dc

Org

Wht/Yel Comm
2nd Wht/Yel ­ Comm

Yel

C

CLOSED

Org

OPEN

AUTO

Org

Wht/Yel

N/O

Comm

2nd Wht/Yel

­

Comm

RIB12C-FA-RD RIB12S-FA-RD · Red housing

RIB12C-FA-N4 · NEMA 4X housing, UL508 only

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIB12C-FA) One (1) SPST Continuous Duty Coil (RIB12S-FA)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple
Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No
Override Switch: No (RIB12C-FA) Yes (RIB12S-FA)
FIRE ALARM RELAYS

Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac

Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 36 mA @ 12 Vdc

Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc

Notes: · Order Normally Closed by adding "NC" to end of model number (RIB12S-FA)

RIB24C-FA
Polarized Relay, 10 Amp SPDT, 24 Vac/dc Coil,
NEMA 1 Housing

RIB24S-FA
Polarized Relay 10 Amp SPST-N/O + Override, 24
Vac/dc Coil, NEMA 1 Housing

2nd Wht/Blu 24 Vac/dc

2nd Wht/Blu 24 Vac/dc

Wht/Blu

+

Blu

Wht/Blu

+

24 Vac/dc

N/C

24 Vac/dc

Org

Yel C

Wht/Yel Comm

2nd Wht/Yel

­

Comm

Org

Wht/Yel

N/O

Comm

2nd Wht/Yel

­

Comm

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIB24C-FA) One (1) SPST Continuous Duty Coil (RIB24S-FA)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple
Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No
Override Switch: No (RIB24C-FA) Yes (RIB24S-FA)

CLOSED

Org

OPEN

AUTO

RIB24C-FA-RD RIB24S-FA-RD · Red housing

RIB24C-FA-N4 · NEMA 4X housing, UL508 only

Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac

Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

Notes: · Order Normally Closed by adding "NC" to end of model number (RIB12S-FA)

(800) 888-5538 | www.functionaldevices.com

75

RELAYS

FIRE ALARM RELAY
RIBT24B-FA
Polarized Relay, 20 Amp SPDT, 24 Vac/dc Coil, Hi/Lo Voltage Separation, NEMA 1 Housing

Blu

Comm ­

N/C

Yel C

Org

24 Vac/dc +

N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No
FIRE ALARM RELAY
RIB24P-FA
Polarized Relay, 20 Amp DPDT, 24 Vac/dc Coil, NEMA 1 Housing

Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

Coil Current: 47 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

2nd Wht/Blu 24 Vac/dc

Wht/Blu

+

24 Vac/dc

Wht/Yel Comm

2nd Wht/Yel

­

Comm

Blu - N/C Yel - C Org - N/O
Gry - N/C Prp - C Brn - N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.75"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No

Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc, 15 Vdc 15 Amp Resistive @ 600 Vac 1 HP @ 120 Vac 2 HP @ 240-277 Vac 3 HP @ 480 Vac - 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac

Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc

76

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

FIRE ALARM TRACK MOUNT RELAYS

RIBMN12C-FA
Polarized Relay, 15 Amp SPDT, 12 Vac/dc Coil,
2.75" Track Mount

RIBMN12S-FA
Polarized Relay, 15 Amp SPST + Override, 12 Vac/dc
Coil, 2.75" Track Mount

12 Vac/dc +

N/C

C

Comm ­

N/O

12 Vac/dc + Comm ­

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN12C-FA) One (1) SPST Continuous Duty Coil (RIBMN12S-FA)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.10"H x 2.75"W x 0.75"D1/1.25"D2 (RIBMN12C-FA) 1.25"H x 2.75"W x 1.25" D1/1.25"D2 (RIBMN12S-FA)
Housing Detail: See Housing H in housing guide for dimensions Origin Made of US and non-US parts
Track Mount: 2.750 MT212 Mounting Track Sold Separately
Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS
Gold Flash: No Override Switch: No (RIBMN12C-FA)
Yes (RIBMN12S-FA)
FIRE ALARM TRACK MOUNT RELAYS

AUTO

C

OPEN

CLOSED

N/O or N/C
Selectable Jumpers (must cut one only)

Cut for N/O
Cut for N/C

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac

Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc

Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc

Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN12S-FA)

RIBMN24C-FA
Polarized Relay, 15 Amp SPDT, 24 Vac/dc Coil,
2.75" Track Mount

RIBMN24S-FA
Polarized Relay, 15 Amp SPST + Override, 24 Vac/
dc Coil, 2.75" Track Mount

24 Vac/dc +

N/C

24 Vac/dc +

AUTO

C

OPEN

CLOSED

C

Comm ­

N/O

Comm ­

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN24C-FA) One (1) SPST Continuous Duty Coil (RIBMN24S-FA)
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.10"H x 2.75"W x 0.75"D1/1.25"D2 (RIBMN24C-FA) 1.25"H x 2.75"W x 1.25" D1/1.25"D2 (RIBMN24S-FA)
Housing Detail: See Housing H in housing guide for dimensions Origin Made of US and non-US parts
Track Mount: 2.750 MT212 Mounting Track Sold Separately
Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS
Gold Flash: No Override Switch: No (RIBMN24C-FA)
Yes (RIBMN24S-FA)

N/O or N/C
Selectable Jumpers (must cut one only)

Cut for N/O
Cut for N/C

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac

Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc

Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S-FA)

(800) 888-5538 | www.functionaldevices.com

77

DRY CONTACT INPUT RELAYS
RIB01SBCDC

RELAYS

RIB21CDC

RIBM01ZNDC

Product Features
· Prepackaged for quick and easy installation · Provides low-voltage (Class 2) power needed to activate the
relay (self-powered) by closing the dry contact input · Activated by a wide range of dry contacts such as
thermostats, switches, other relays, solid-state switches, etc. · Power to energize the relay can be brought to the relay on a
separate pair of wires along with the control output of the controller, or can be a local power source near the relay · Relay contacts are isolated from the input power and the dry contact input, so they can be wired to switch any other power-load or low-voltage load (see specifications for contact ratings)

Typical Application

Current sensing may be internal or external

Load Wire

Load 1

Local Power 120, 240, 277 Vac

RIBX Series
Current Sensor Only

(Class 2)

Current Sensor Status

Dry Contact Input RIB®

Load 2

Self-powered current switches of the RIBX Series and relays of the Dry Contact Input RIB® Series may be applied to interlock Load 2 to Load 1.

ENCLOSED DRY CONTACT INPUT RELAYS

MODEL #

RIB21CDC

·

RIB01BDC

·

RIB02BDC

·

RIB01SBDC

·

RIB02SBDC

·

RIB01SBCDC

·

RIB02SBCDC

·

RIBD01BDC ~ ·

RIBD02BDC ~ ·

POWER INPUT 120-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac

RELAY CONTACTS
1 SPDT 1 SPDT 1 SPDT 1 SPST 1 SPST 1 SPDT 1 SPDT 1 SPDT 1 SPDT

RESISTIVE 10 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac 20 A @ 277 Vac

CONTACT RATINGS

MOTOR 1 HP @ 250 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac 2 HP @ 277 Vac

PILOT DUTY 770 VA @ 250 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac 1,110 VA @ 277 Vac

HIGH/LOW SEPARATION
· ·

OVERRIDE SWITCH
1 1 2 2

HOUSING STYLE * A B B B B B B C C

SPEC PAGE
79 79 79 80 80 80 80 81 81

TRACK MOUNT DRY CONTACT INPUT RELAYS

CONTACT RATINGS

MODEL #
RIBM01ZNDC ·

POWER INPUT
120 Vac

RELAY CONTACTS
1 DPDT

RESISTIVE 30 A @ 300 Vac

MOTOR 3 HP @ 480-600 Vac

PILOT DUTY B600

OVERRIDE SWITCH

TRACK

SPEC

MOUNT ^ PAGE

MT4 Series

83

RIBM02ZNDC · 208-277 Vac

1 DPDT

30 A @ 300 Vac

3 HP @ 480-600 Vac

B600

MT4 Series

83

RIBM013PNDC ·

120 Vac

1 3PDT

30 A @ 300 Vac 7.5 HP @ 480 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase

MT4 Series

83

= UL Listed - see data sheet for specific Listing = UL Component Recognized - see data sheet for specific Listing

* = See Housing Guide on page 201 ^ = Track mount sold separately

~ = Time Delay

78

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

DRY CONTACT INPUT RELAYS
RIB21CDC
Dry Contact Relay, 10 Amp SPDT, Class 2 Dry Contact Input, 120-277 Vac Power Input, NEMA 1 Housing

Org N/O

Blk 120 - 277 Vac

Yel

Red

CONTROL

C

Neutral or Other Phase CIRCUIT

Dry Contact Input

Blu

N/C

Wht/Blu

Wht/Red

RIB21CDC-RD · Red housing

RIB21CDC-N4 · NEMA 4X housing, UL508 only

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac

DRY CONTACT INPUT RELAYS
RIB01BDC
Dry Contact Relay, 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input, NEMA 1 Housing

RIB02BDC
Dry Contact Relay, 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input, NEMA 1 Housing

Org N/O

Blk 120 Vac

Yel

Wht

CONTROL

C

Neutral

CIRCUIT

Blu N/C
Dry Contact Input Wht/Red
Wht/Blu

Org N/O

Blk 208-277 Vac

Yel

Red

CONTROL

C

Neutral or Other Phase CIRCUIT

Blu N/C
Dry Contact Input Wht/Red
Wht/Blu

Power Input: 50 mA @ 240 Vac Max.
Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common.

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

Power Input: 42 mA @ 120 Vac (RIB01BDC) 62 mA @ 208-277 Vac (RIB02BDC)
Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common.

((880000)) 888888--55553388 || wwwwww..ffuunnccttiioonnaallddeevviicceess..ccoomm

7799

RELAYS

DRY CONTACT INPUT RELAYS
RIB01SBDC
Dry Contact Relay, 20 Amp SPST-N/O + Override, Class 2 Dry Contact Input, 120 Vac Power Input, NEMA 1 Housing

RIB02SBDC
Dry Contact Relay, 20 Amp SPST-N/O + Override, Class 2 Dry Contact Input, 208-277 Vac Power Input, NEMA 1 Housing

Blk 120 Vac
Wht Neutral

CONTROL CIRCUIT

CLOSED OPEN AUTO

Blk 208-277 Vac
Red Neutral or Other Phase

CONTROL CIRCUIT

CLOSED OPEN AUTO

Org

Org

Org

Org

Dry Contact Input

Dry Contact Input

Wht/Red

Wht/Red

Wht/Blu

Wht/Blu

SPECIFICATIONS

DRY CONTACT INPUT RELAY

# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes

Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

DRY CONTACT INPUT RELAYS

RIB01SBCDC
Dry Contact Relay, 20 Amp SPDT + Override, Class 2 Dry Contact Input, 120 Vac Power Input, NEMA 1 Housing

RIB02SBCDC
Dry Contact Relay, 20 Amp SPDT + Override, Class 2 Dry Contact Input, 208-277 Vac Power Input, NEMA 1 Housing

Blk 120 Vac
Wht Neutral

CONTROL CIRCUIT

Blk 208-277 Vac
Red Neutral or Other Phase

CONTROL CIRCUIT

Dry Contact Input Wht/Red Wht/Blu

Yel C
MANUAL AUTO

Blu N/C

Org

OPEN

N/O

N/C

N/O

CLOSED CLOSED

Dry Contact Input Wht/Red Wht/Blu

Yel C
MANUAL AUTO

Blu N/C

Org

OPEN

N/O

N/C

N/O

CLOSED CLOSED

Power Input: 42 mA @ 120 Vac (RIB01SBDC) 62 mA @ 208-277 Vac (RIB02SBDC)
Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. · Order Normally Closed by adding "-NC" to end of model number

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2)

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Power Input: 42 mA @ 120 Vac (RIB01SBCDC) 62 mA @ 208-277 Vac (RIB02SBCDC)
Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common.

80

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

DRY CONTACT INPUT TRIEMLEAYDELAY RELAYS

RIBD01BDC
Time Delay Dry Contact Relay, 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input, NEMA 1 Housing

RIBD02BDC
Time Delay Dry Contact Relay, 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input, NEMA 1 Housing

Org N/O

Wht/Blk 120 Vac

Yel

Wht/Blk

CONTROL

C

Neutral

CIRCUIT

Blu N/C
Dry Contact Input Wht/Red
Wht/Blu

Org N/O

Wht/Brn 208-277 Vac

Yel

Wht/Brn

CONTROL

C

Neutral or Other Phase CIRCUIT

Blu N/C
DRY CONTACT INPUT Wht/Red
Wht/Blu

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms after time delay Relay Status: Red LED On = Activated
Time Delay Status: Pink LED FLASHING = Timing Timing Mode: Selectable: Delay On Make, Delay On Break, or Delay On Make and Break Timing Range: 1-30 Seconds or 1-30 Minutes
Timing Adjustment: 3 pin header w/jumper for sec/min and single turn potentiometer for timing adjustment within range
Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions
Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input: 66 mA @ 120 Vac (RIBD01BDC) 62 mA @ 208-277 Vac (RIBD02BDC)

Notes: · Dry Contact Input Operation: Mode A&C: Close White/Red wire to White/Blue wire to start timing. Relay will activate after timing sequence has ended. · Mode B&C: Open White/Red and White/Blue wires to start timing. Relay will deenergize after timing sequence has ended. · If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. · Changing min/sec or mode while unit is running will reset the unit (de-energize the relay and turn off the timer). Once the dry-contact input is opened the unit will function as normal again · If the unit is powered up with the dry-contact input closed, the unit will begin timing (MODE A and MODE C) or energize the relay (MODE B).

Wiring for Load on N/O Contact

120 Vac Neutral

Org Switched Power to Load
Yel Continuous Power

Wiring for Load on N/C Contact

120 Vac

Blu Switched Power to Load

Neutral

Yel Continuous Power

MODE A: DELAY ON MAKE

Dry Contact Input

Closed Open

Load on N/C Contact
Load on N/O Contact
(Not as commonly used but absolutely may be used)

Time Delay

Time Delay

On

Time Delay

Time Delay

O

(Retriggered)

On O

Dry Contact Input

(800) 888-5538 | www.functionaldevices.com

Continued next page

Closed

Open

81

RELAYS

Load on N/C Contact

Time Delay

DRY CONTACTLoLoaIdaNdoonPnNNU/O/CCTCoonnTtRtaacIcEttMLEAYDELTAimYe DeRlayELAYS - CONTINUED
(Not as commonly used but
MODE B: DELAYabsoOluteNly maBy bRe uEsedA) K
Load on N/O Contact
(Not as commonly used but absolutely may be used)

Time Delay Time Delay

Dry Contact Input

Dry Contact Input

Load on N/C Contact

Time Delay

Load on N/O Contact (NotLaosacdomonmoNn/lCy uCsoendtbauctt
absolutely may be used)
Load on N/O Contact
(Not as commonly used but absolutely may be used)

Time Delay

MODE C: DELAY ON MAKE AND DELAY ON BREAK
Dry Contact Input

Time Delay Time Delay

Dry Contact Input

Load on N/C Contact

DOM

Load on N/O Contact

(NoatLbaossaocdloumtoenmly oNmn/alCyy ubCseoeundstbeaudct)t

DOM

Load on N/O Contact
(Not as commonly used but absolutely may be used)

DOB

DOB

DOB

DO(MRetriggered)

DOB

DOM DOB

DOB

(Retriggered)

Time Delay Time Delay

On

Time Delay

O

(Retriggered)

On

Time Delay
(Retriggered)

O On

O On

O

Time Delay Time Delay

Time Delay
(Retriggered)
Time Delay
(Retriggered)

Closed Open Closed Open On O
On O On
O
On O

DOB

DOB

(Retriggered)

DOB

DOB

(Retriggered)

Closed Open Closed OpOenn O
OnOn OO
On O

82

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS

DRY CONTACT INPUT TRREALACYK MOUNT RELAYS

RIBM01ZNDC
Dry Contact Relay, 30 Amp DPDT, Class 2 Dry Contact Input, 120 Vac Power Input, 4.00" Track Mount

RIBM02ZNDC
Dry Contact Relay, 30 Amp DPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input, 4.00" Track Mount

N/C

DCI

Dry Contact

N/O

Input

CONTROL

CIRCUIT

C

DCI COM

N/C POWER INPUT

Neutral N/O

120 Vac

C

N/C

DCI

Dry Contact

N/O

Input

CONTROL

CIRCUIT

C

DCI COM

N/C POWER INPUT

Neutral or Other Phase N/O

208-277 Vac

C

SPECIFICATIONS
# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: Red LED On = Activated Power Status: Green LED On = Activated Dimensions: 2.88"H x 4.00"W x 1.50"D1/2.00"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000" MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: Yes Override Switch: No

Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast

770 VA @ 120 Vac 1158 VA @ 240 Vac 1109 VA @ 277 Vac 1640 VA @ 480 Vac NEMA B600 Pilot Duty

DRY CONTACT INPUT TRREALACYK MOUNT RELAY

RIBM013PNDC
Dry Contact Relay, 30 Amp 3PDT, Class 2 Dry Contact Input, 120 Vac Power Input, 4.00" Track Mount
N/C

Power Input: 95 mA @ 120 Vac (RIBM01ZNDC) 95 mA @ 208-277 Vac (RIBM01ZNDC)
Notes: · Dry Contact Input Operation: Close dry contact to activate relay. · If more than one dry contact input RIB shares a single dry contact input, DCI COM must be common.

N/O

DCI

C

DRY CONTACT CONTROL

N/C

INPUT

CIRCUIT

DCI COM

N/O

POWER INPUT

C

N/C Neutral

120 Vac N/O
C

SPECIFICATIONS

# Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Power Status: Green LED On = Activated Dimensions: 2.88"H x 4.00"W x 1.50"D1/2.00"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: No Override Switch: No

Contact Ratings: 30 Amp Resistive @ 300 Vac 30 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240/277 Vac, 1 Phase 1 HP @ 120 Vac, 1Phase 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast

Heavy Pilot Duty 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1109 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase

Power Input: 95 mA @ 120 Vac
Notes: · Dry Contact Input Operation: Close dry contact to activate relay. · If more than one dry contact input RIB shares a single dry contact input, DCI COM must be common.

(800) 888-5538 | www.functionaldevices.com

83

CURRENT SENSORS

RIBMX24BF

RIBX24SBA

RIBHX24BA

SCSCEEUUNNRRSSRREOEORRNNSSTT

RIBXGTV10

RIBXKTA

RIB® CURRENT SENSORS, TRANSDUCERS, AND RELAY AND SENSOR COMBOS ARE PREPACKAGED TO MAKE INSTALLATION EASY

· Prepackaged: Sensor, LED indicators,  and wires or terminals
· Some models available with 10 Amp or  20 Amp relay
· Sense up to 150 Amps · Split and solid core models · Fixed or adjustable thresholds

· Hi/Low voltage separation · Transducers with voltage output  or 4-20mA regulation available · Enclosed or track mount · HOA switches available · UL Listed

LOW THRESHOLD CURRENT SWITCH FOR ECM APPLICATIONS
ECM SENSOR VIEW VIDEO

RIBXGTA-ECM
0.25 Amp Adjustable Threshold | Sense Loads up to 150 Amps | 10% Hysteresis Split Core | UL Listed | Terminals | LEDs for Line & Load Indication

84

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

CURRENT SENSORS

CURRENT SENSORS

SOLID AND SPLIT CORE AC SENSORS

MODEL # RIBXKF RIBXKTF RIBXKA

SENSING

SENSOR CONTACT SWITCHING MAX. SWITCHING

RANGE TYPE THRESHOLD

TYPE

VOLTAGE RANGE CURRENT

SENSOR CONTACT TERMINATION

SENSOR SPEC OUTPUT * PAGE

· .25-150 A Solid Fixed, .25 Amp Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

87

· .25-150 A Solid Fixed, .25 Amp Solid State Switch SPST

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

87

· .50-150 A Solid Adjustable Solid State Switch SPST

30 Vac/dc

.8 Amps Max

Wht/Yel 16 18 AWG Wire Leads

87

RIBXKTA

· .50-150 A Solid Adjustable Solid State Switch SPST

30 Vac/dc

.8 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

87

RIBXKNUTA

· .20-150 A Solid Adjustable Solid State Switch SPST

30 Vac/dc

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

87

RIBXGHF

· .50-150 A Split Fixed, .50 Amp Solid State Switch SPST 120 Vac only

1 Amp Max

Wht/Blk 16 18 AWG Wire Leads

87

RIBXGHTF

· .50-150 A Split Fixed, .50 Amp Solid State Switch SPST 120 Vac only

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

87

RIBXGHA

· .75-150 A Split Adjustable Solid State Switch SPST 120 Vac only

1 Amp Max

Wht/Blk 16 18 AWG Wire Leads

87

RIBXGHTA

· .75-150 A Split Adjustable Solid State Switch SPST 120 Vac only

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

87

RIBXGF

· .35-150 A Split Fixed, .35 Amp Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

88

RIBXGFL

· .75-150 A Split Fixed, .75 Amp Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

88

RIBXGTF

· .35-150 A Split Fixed, .35 Amp Solid State Switch SPST

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

88

RIBXGTFL

· .75-150 A Split Fixed, .75 Amp Solid State Switch SPST

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

88

RIBXGA

· .75-150 A Split Adjustable Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

88

RIBXGTA

· .75-150 A Split Adjustable Solid State Switch SPST

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

88

RIBXGTA-ECM · .25-150 A Split Adjustable Solid State Switch SPST

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

88

RIBXGA-SCAL

· 3-150 A Split Self-Calibrating Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Wht/Yel 16 18 AWG Wire Leads

88

RIBXGTA-SCAL · 3-150 A Split Self-Calibrating Solid State Switch SPST

30 Vac/dc

.4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

88

RIBXGTA-NC

· .75-150 A Split Adjustable Solid State Switch SPST

30 Vac/dc

.1 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

89

RIBXGTF-NC

· .35-150 A Split Fixed, .35 Amp Solid State Switch SPST

30 Vac/dc

.1 Amps Max Terminal Strip, Accepts #14-22 AWG Wire

89

RIBXG21F

· .50-150 A Split Fixed, .50 Amp Solid State Switch SPST 120-277 Vac

1 Amp Max

Wht/Blk 16 18 AWG Wire Leads

89

RIBXG21TF

· .50-150 A Split Fixed, .50 Amp Solid State Switch SPST 120-277 Vac

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

89

RIBXG21A

· .75-150 A Split Adjustable Solid State Switch SPST 120-277 Vac

1 Amp Max

Wht/Blk 16 18 AWG Wire Leads

89

RIBXG21TA

· .75-150 A Split Adjustable Solid State Switch SPST 120-277 Vac

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

89

RIBXGNTF

· .35-150 A Split Fixed, .35 Amp Solid State Switch SPST

30 Vac/dc

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

90

RIBXGNTA

· .75-150 A Split Fixed, .75 Amp Solid State Switch SPST

30 Vac/dc

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

90

RIBXGNTF-125 · .125-150 A Split Fixed, .125 Amp Solid State Switch SPST

30 Vac/dc

1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire

90

RIBXKTV5-10

· 0-10 A Solid Analog

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc

90

RIBXKTV5-20

· 0-20 A Solid Analog

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc

90

RIBXKTV5-50

· 0-50 A Solid Analog

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc

90

RIBXKTV5-100 · 0-100 A Solid Analog

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc

90

RIBXK420-20

· 0-20 A Solid Analog

Red & Blk 16 18 AWG Wire Leads

4-20 mA

91

RIBXK420-50

· 0-50 A Solid Analog

Red & Blk 16 18 AWG Wire Leads

4-20 mA

91

RIBXK420-100 · 0-100 A Solid Analog

Red & Blk 16 18 AWG Wire Leads

4-20 mA

91

RIBXGTV5-10

·

0-10 A Split Analog

Terminal Strip, Accepts #14-22 AWG Wire 4-20 mA

91

RIBXGTV5
RIBXGTV10 RIBXG420-20 RIBXG420-50 RIBXG420-100

·

0-20 A, 0-50 A, 0-100 A

Split

·

0-20 A, 0-50 A, 0-100 A

Split

· 0-20 A Split

· 0-50 A Split

· 0-100 A Split

Analog
Analog Analog Analog Analog

Terminal Strip, Accepts #14-22 AWG Wire 0-5 Vdc

92

Terminal Strip, Accepts #14-22 AWG Wire 0-10 Vdc

92

Red & Blk 16 18 AWG Wire Leads

4-20 mA

93

Red & Blk 16 18 AWG Wire Leads

4-20 mA

93

Red & Blk 16 18 AWG Wire Leads

4-20 mA

93

RIBXGT420-RMS

·

0-20 A, 0-50 A, 0-100 A

Split

Analog

Terminal Strip, Accepts #14-22 AWG Wire 4-20 mA

94

T STYLE AC SENSORS

MODEL # RIBXF RIBXA RIBXV RIBXRF RIBXRA RIBXJF RIBXJA

SENSING

SENSOR

SWITCHING MAX. SWITCHING

SENSOR CONTACT

RANGE TYPE THRESHOLD CONTACT TYPE VOLTAGE RANGE CURRENT

TERMINATION

· .50-30 A Internal Fixed, .50 Amp Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

· .50-30 A Internal Adjustable Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

· 0-30 A Internal Analog

Terminal Strip, Accepts #14-22 AWG Wire

· 1.25-150 A Solid Fixed, 1.25 Amp Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

· 1.25-150 A Solid Adjustable Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

· 3-150 A Split Fixed, 3 Amp Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

· 3-150 A Split Adjustable Solid State Switch SPST

30 Vac/dc

.4 Amps Max

Terminal Strip, Accepts #14-22 AWG Wire

SENSOR OUTPUT
0-5 Vdc / 0-10 Vdc

SPEC PAGE
95 95 95 95 95 96 96

= UL Listed - see data sheet for specific Listing * = 4-20 mA is Loop Powered Refer to Housing Guide on page 201 or product data sheet for housing information.

(800) 888-5538 | www.functionaldevices.com

85

CURRENT SENSORS

CURRENT SENSOR & RELAY COMBINATIONS

ENCLOSED AC SENSORS WITH RELAYS

MODEL # RIBHX24BF RIBHX24BA RIBXLCF RIBXLCA
RIBXLCV
RIBXLCRF RIBXLCRA RIBXLCJF RIBXLCJA RIBXLCEA
RIBXLCEV
RIBXLSF RIBXLSA
RIBXLSV
RIBXLSRF RIBXLSRA RIBXLSJF RIBXLSJA RIBXLSEA
RIBXLSEV
RIBX24BF RIBX24BA
RIBX24BV
RIBX24SBF RIBX24SBA
RIBX24SBV
RIBX243PV RIBX243PF RIBX243PA

COIL

RELAY OVERRIDE

VOLTAGE CONTACTS SWITCH

· 24 Vac 1 SPST-N/O

· 24 Vac 1 SPST-N/O

· 10-30 Vac/dc 1 SPDT

· 10-30 Vac/dc 1 SPDT

· 10-30 Vac/dc 1 SPDT

· 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc

1 SPDT 1 SPDT 1 SPDT 1 SPDT 1 SPDT

· 10-30 Vac/dc 1 SPDT

· 10-30 Vac/dc 1 SPST

1

· 10-30 Vac/dc 1 SPST

1

· 10-30 Vac/dc 1 SPST

1

· 10-30 Vac/dc 1 SPST

1

· 10-30 Vac/dc 1 SPST

1

· 10-30 Vac/dc 1 SPST

1

· 10-30 Vac/dc 1 SPST

1

· 10-30 Vac/dc 1 SPST

1

· 10-30 Vac/dc 1 SPST

1

· 24 Vac/dc 1 SPDT · 24 Vac/dc 1 SPDT

· 24 Vac/dc 1 SPDT

· 24 Vac/dc 1 SPST

1

· 24 Vac/dc 1 SPST

1

· 24 Vac/dc 1 SPST

1

· 24 Vac/dc · 24 Vac/dc · 24 Vac/dc

1 3PST 1 3PST 1 3PST

RESISTIVE 20 A @ 277 Vac 20 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac
10 A @ 277 Vac
10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 5 A @ 277 Vac
5 A @ 277 Vac
10 A @ 277 Vac 10 A @ 277 Vac
10 A @ 277 Vac
10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 10 A @ 277 Vac 5 A @ 277 Vac
5 A @ 277 Vac
20 A @ 277 Vac 20 A @ 277 Vac
20 A @ 277 Vac
20 A @ 277 Vac 20 A @ 277 Vac
20 A @ 277 Vac
20 A @ 300 Vac 20 A @ 300 Vac 20 A @ 300 Vac

SENSING
RANGE TYPE~ THRESHOLD

SENSOR CONTACT TYPE

SWITCHING MAX. VOLTAGE SWITCHING SENSOR RANGE CURRENT OUTPUT

SPEC PAGE

.25-20 A Internal Fixed, .25 Amp Solid State Switch Contact 30 Vac/dc .1 Amps Max

97

.25-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .1 Amps Max

97

.50-10 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

98

.50-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

98

0-10 A Internal Analog

0-5 Vdc / 0-10 Vdc

98

1.25-150 A External Fixed, 1.25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

98

1.25-150 A External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

98

3-150 A External Fixed, 3 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

98

3-150 A External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

98

.125 - 5 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

98

0 - 5 A Internal Analog

0-5 Vdc / 0-10 Vdc

98

.50-10 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

99

.50-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

99

0 - 10 A Internal Analog

0-5 Vdc / 0-10 Vdc

99

1.25-150 A External Fixed, 1.25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

99

1.25-150 A External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

99

3-150 A External Fixed, 3 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

99

3-150 A External Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

99

.125 - 5 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

99

0 - 5 A Internal Analog

0-5 Vdc / 0-10 Vdc

99

.50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

100

.50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

100

0-20 A Internal Analog

0-5 Vdc / 0-10 Vdc

100

.50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

100

.50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

100

0-20 A Internal Analog

0-5 Vdc / 0-10 Vdc

100

0-20 A Internal Analog

0-10 Vdc 103

.50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

103

.50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

104

DIN MOUNT AC SENSORS WITH RELAYS

MODEL #

COIL

RELAY OVERRIDE

SENSING

VOLTAGE CONTACTS SWITCH RESISTIVE RANGE TYPE ~ THRESHOLD

SENSOR CONTACT TYPE

SWITCHING MAX.

TRACK

VOLTAGE SWITCHING NO MOUNT SPEC

RANGE CURRENT SOCKET ^

PAGE

RIBRXLCF-NS · 10-30 Vac/dc 1 SPST

10 A @ 277 Vac .25-10 A Internal Fixed, .25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max · DIN Rail 101

RIBRXLSA-NS RIBRXLCF RIBRXLSA

· 10-30 Vac/dc · 10-30 Vac/dc · 10-30 Vac/dc

1 SPST 1 SPST 1 SPST

1 10 A @ 277 Vac .25-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max · DIN Rail 101

10 A @ 277 Vac .25-10 A Internal Fixed, .25 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

DIN Rail 102

1 10 A @ 277 Vac .25-10 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

DIN Rail 102

TRACK MOUNT AC SENSORS WITH RELAYS

MODEL #

COIL

RELAY OVERRIDE

SENSING

VOLTAGE CONTACTS SWITCH RESISTIVE RANGE TYPE ~ THRESHOLD

SENSOR CONTACT TYPE

SWITCHING MAX.

TRACK

VOLTAGE SWITCHING SENSOR MOUNT

RANGE CURRENT OUTPUT ^

SPEC PAGE

RIBMX24BF · 24 Vac/dc 1 SPDT

20 A @ 277 Vac .50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

MT4 Series 105

RIBMX24BA · 24 Vac/dc 1 SPDT

20 A @ 277 Vac .50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

MT4 Series 105

RIBMX24SBF · 24 Vac/dc 1 SPST

1 20 A @ 277 Vac .50-20 A Internal Fixed, .50 Amp Solid State Switch Contact 30 Vac/dc .4 Amps Max

MT4 Series 105

RIBMX24SBA · 24 Vac/dc 1 SPST

1 20 A @ 277 Vac .50-20 A Internal Adjustable Solid State Switch Contact 30 Vac/dc .4 Amps Max

MT4 Series 105

RIBMX24SBV · 24 Vac/dc 1 SPST

1 20 A @ 277 Vac 0-20 A Internal Analog

0-5 Vdc / 0-10 Vdc

MT4 Series

105

= UL Listed - see data sheet for specific Listing

~ = Internal current sensor monitors current through common contact of relay

^ = Track mount sold separately

86

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

CURRENT AC CURRENT SWITCHES SENSOR & RELAY COMBINATIONS
RIBXK Series
Current Switches, Solid Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, Terminal Strip or Wire Lead Output
1.46"

CURRENT SENSORS

.500" Diameter
Wire Clamp

1.863" 2.050"

LED 2 LED 1 (if present)

1.008"

1.508"

Threshold Adjust

Sensor Contact

Removable Mounting Tab

SPECIFICATIONS

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Max Sense Voltage: 600 Vac Approvals: UL Listed, C-UL, CE, RoH, UL916, S (All models) UL864, California State Fire Marshal (RIBXKTF, RIBXKTA)
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Contact Output: Current below threshold: Open ; Current above threshold: Closed Origin: Made of US and non-US parts

RIBXKA Wire Being Monitored
Wht/ Yel

RIBXKTF Wire Being Monitored

Wht/ Yel

Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp

RIBXK SERIES SELECTION GUIDE

Model#

Sensing Range

Type Threshold

Sensor Contact
Type

Switching Voltage Range

RIBXKF

.25-150 Amp Solid Core Fixed, .25 Amp Solid State Switch SPST 30 Vac/dc

RIBXKTF

.25-150 Amp Solid Core Fixed, .25 Amp Solid State Switch SPST 30 Vac/dc

RIBXKA

.50-150 Amp Solid Core Adjustable Solid State Switch SPST 30 Vac/dc

RIBXKTA

.50-150 Amp Solid Core Adjustable Solid State Switch SPST 30 Vac/dc

RIBXKNUTA .2-150 Amp Solid Core Adjustable Solid State Switch SPST 30 Vac/dc

Maximum Switching Current .4 Amps Max
.4 Amps Max
.8 Amps Max
.8 Amps Max
1 Amp Max

Sensor Contact Termination

LED 1

LED 2

Wht/Yel 16 18 AWG Wire Leads

Terminal Strip, Accepts #14-22 AWG Wire

Wht/Yel 16 18 AWG Wire Leads

Over Trip Point Under Trip Point

Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point Under Trip Point

Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point Under Trip Point

AC CURRENT SWITCHES

RIBXGH Series
Current Switches, Split Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, 120 Vac Switching Voltage,
Terminal Strip or Wire Lead Output
Wire Clamp

2.000"

Sensor Contact

RIBXGHF

RIBXGHTF

.52" x .52" ­ Opening for Wire Being Monitored
2.520"

LED 2 LED 1 Threshold Adjust (if present)
2.000"

Wire Being Monitored

Wire Being Monitored

1.100" 1.750"
Removable Mounting Tab

Wht/Blk Wht/Blk

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
*Temperature Derating: 1 Amp up to 50° C, 0.5 Amp up to 60° C Max Sense Voltage: 600 Vac
Sensor Contact Status: Current below threshold: Open Current above threshold: Closed

Origin: Made of US and non-US parts Approvals: UL Listed, UL916, C-UL, CE, RoHS Mounting/ Removable mounting tab provided. The Installation: wire clamp locks against the wire being
monitored, securing the unit in place.

Notes: · Use Sensor Contact to switch 120 Vac loads only. · For testing purposes, Sensor Contact will measure approximately 250  when closed and > 10 M when open. · The Sensor Contact is a Solid State Contact.

RIBXGH SERIES SELECTION GUIDE

Model#

Sensing Range

Type

Threshold

Sensor Contact
Type

Switching Voltage Range

RIBXGHF .50-150 Amp Split Core Fixed, .50 Amp Solid State Switch SPST 120 Vac Only*

RIBXGHTF .50-150 Amp Split Core Fixed, .50 Amp Solid State Switch SPST 120 Vac Only*

RIBXGHA .75-150 Amp Split Core Adjustable Solid State Switch SPST 120 Vac Only*

RIBXGHTA .75-150 Amp Split Core Adjustable Solid State Switch SPST 120 Vac Only*

Maximum Switching Current 1 Amp Max
1 Amp Max
1 Amp Max
1 Amp Max

Sensor Contact Termination

LED 1

LED 2

Wht/Blk 16 18 AWG Wire Leads

Terminal Strip, Accepts #14-22 AWG Wire

Wht/Blk 16 18 AWG Wire Leads

Over Trip Point Under Trip Point

Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point Under Trip Point

(800) 888-5538 | www.functionaldevices.com

87

CURRENT SENSORS

AC CURRENT SWITCHES

RIBXG Series
Current Switches, Split Core, Fixed, Adjustable, or Self-Calibrated, Up to 150 Amps Sensing Range,
Terminal Strip or Wire Lead Output

Wire Clamp 2.000"

Sensor Contact

.52" x .52" ­ Opening for Wire Being Monitored
2.520"

LED 2 LED 1 Threshold Adjust (if present)
2.000"

1.100" 1.750"

Removable Mounting Tab
SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Max Sense Voltage: 600 Vac Approvals: UL Listed, C-UL, CE, RoHS, UL916, (All models) UL864, California State Fire Marshal (RIBXGTF, RIBXGTA, RIBXGTA-SCAL, RIBXGA-ECM)
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Contact Status: Current below threshold: Open Current above threshold: Closed
Origin: Made of US and non-US parts
SELF-CALIBRATING AC SWITCHES (Models with -SCAL Suffix)

Sensor Contact
LED 1 DIP Switch

-SCAL LED TABLE

LED Off

No Current

Two Winks

Current Below Range

Three Winks

Current In Range

Four Winks

Current Above Range

Continuous Winks Calibration in Progress

The SCAL unit begins the 30 second self-calibration process the first time current is applied in the operating range. The threshold is then set. Subsequent calibrations may be performed by moving SW1 to the position opposite of its current position with or without current applied (hands can be safely away from live voltage). Once current begins flowing, or if it already is, the calibration process will begin. At the end of the 30 seconds, amperage will be read and set as the threshold. SW2 in the ON position provides a 15% (+/-3%) differential. In the OFF position, it provides a 25% (+/-3%) differential. SW2 can be selected at anytime and does not affect the threshold setting. Current in-range closes the sensor contact. Current above or below range opens the sensor contact.

RIBXGA

RIBXGTF

Wire Being Monitored
Wht/Yel Wht/Yel

Wire Being Monitored

Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage
<30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop
< .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp

RIBXGA-SCAL

RIBXGTA-SCAL

Example: With a current of 10 amps set as the threshold and a 15% differential, sensor contact will be closed between 8.5 amps and 11.5 amps and open outside of this range. A small amount of hysteresis is provided to prevent dithering near the differential limits.

RIBXG SERIES SELECTION GUIDE

Model#

Sensing Range

Type Threshold

Sensor Contact Type

RIBXGF

.35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST

Switching Voltage Range
30 Vac/dc

Maximum Switching Current
.4 Amps Max

RIBXGFL*

.75-150 Amp Split Core Fixed, .75 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max

RIBXGTF

.35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max

RIBXGTFL*

.75-150 Amp Split Core Fixed, .75 Amp Solid State Switch SPST 30 Vac/dc .4 Amps Max

RIBXGA

.75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max

RIBXGTA

.75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max

RIBXGA-SCAL 3-150 Amp Split Core Self-Cal. Solid State Switch SPST 30 Vac/dc .4 Amps Max

RIBXGTA-SCAL 3-150 Amp Split Core Self-Cal. Solid State Switch SPST 30 Vac/dc .4 Amps Max

RIBXGTA-ECM .25-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc .4 Amps Max

* = Not approved by California State Fire Marshal

Sensor Contact Termination Wht/Yel 16 18 AWG Wire Leads Wht/Yel 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire Wht/Yel 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire Wht/Yel 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire

LED 1
Over Trip Point
Over Trip Point Over Trip Point Over Trip Point See -SCAL Table See -SCAL Table

LED 2
Under Trip Point Under Trip Point

Terminal Strip, Accepts #14-22 AWG Wire Over Trip Point Load Current Detcted

88

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

AC CURRENT SWITCHES

RIBXG-NC Series
Current Switches, Split Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, Normally Closed Terminal Strip or Wire Lead Output

Wire Clamp 2.000"

Sensor Contact

RIBXGTF-NC

.52" x .52" ­ Opening for Wire Being Monitored
2.520"

Threshold Adjust 2.000"

LED 2 LED 1 (if present)

1.100" 1.750"

Wire Being Monitored

CURRENT SENSORS

Removable Mounting Tab
SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Contact Status: Current below threshold: Closed Current above threshold: Open
Origin: Made of US and non-US parts

Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage
<30 uA @ 30Vac/dc · When sensor contact is on (closed), resistance
11.2 ohm

RIBXG-NC SERIES SELECTION GUIDE

Model#

Sensing Range

Type Threshold

Sensor Contact Type

RIBXGTF-NC .35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST

Switching Voltage Range
30 Vac/dc

RIBXGTA-NC .75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc

Maximum Switching Current
.1 Amps Max
.1 Amps Max

Sensor Contact Termination
Terminal Strip, Accepts #14-22 AWG Wire
Terminal Strip, Accepts #14-22 AWG Wire

LED 1

LED 2

Over Trip Point Under Trip Point

AC CURRENT SWITCHES

RIBXG21 Series
Current Switches, Split Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, 120-277 Vac Switching
Voltage, Terminal Strip or Wire Lead Output

Wire Clamp 2.000"

Sensor Contact

.52" x .52" Opening for Wire Being Monitored
2.520"

LED 2 LED 1 Threshold Adjust (if present)
2.000"

RIBXG21F
Wire Being Monitored

RIBXG21TF
Wire Being Monitored

1.100" 1.750"

Wht/Brn

Removable Mounting Tab
SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
* Temperature Derating: 1 Amp up to 50° C, 0.5 Amp up to 60° C
Max Sense Voltage: 600 Vac Sensor Contact Status: Monitored current below threshold: Open
Monitored current above threshold: Closed

Wht/Brn
Approvals: UL Listed, UL916, C-UL, CE, RoHS
Mounting/ Unit can be secured using the Installation: supplied Mounting Tab, the
adjustable Wire Clamp, or both. Origin: Made of US and non-US parts

Notes: · Use Sensor Contact to switch 120-277 Vac loads only. · For testing purposes, Sensor Contact will measure approximately 250  when closed and > 10 M when open. · The Sensor Contact is a Solid State Contact.

RIBXG21 SERIES SELECTION GUIDE

Model#

Sensing Range

Type

Threshold

Sensor Contact
Type

RIBXG21F .50-150 Amps AC Split Core Fixed, .50 Amp AC Solid State Switch SPST

RIBXG21TF .50-150 Amps AC Split Core Fixed, .50 Amp AC Solid State Switch SPST

RIBXG21A .75-150 Amps AC Split Core

Adjustable Solid State Switch SPST

RIBXG21TA .75-150 Amps AC Split Core

Adjustable Solid State Switch SPST

Switching Voltage Range 120-277 Vac
120-277 Vac
120-277 Vac
120-277 Vac

Maximum Switching Current
1 Amp AC *
1 Amp AC *
1 Amp AC *
1 Amp AC *

Sensor Contact Termination

LED 1

LED 2

Wht/Blk 16 18 AWG Wire Leads

Terminal Strip, Accepts #14-22 AWG Wire

Wht/Blk 16 18 AWG Wire Leads

Over Threshold Under Threshold

Terminal Strip, Accepts #14-22 AWG Wire Over Threshold Under Threshold

(800) 888-5538 | www.functionaldevices.com

89

CURRENT SENSORS

AC CURRENT SWITCHES

RIBXGN Series
Current Switches, Split Core, Fixed or Adjustable, Up to 150 Amps Sensing Range, 1 Amps Switching Current, Terminal Strip Output

Wire Clamp

RIBXGNTF

2.000"

Sensor Contact

.52" x .52" ­ Opening for Wire Being Monitored
2.520"

LED 2 LED 1 Threshold Adjust (if present)
2.000"

1.100" 1.750"

Wire Being Monitored

Removable Mounting Tab
SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Contact Status: Current below threshold: Open Current above threshold: Closed
Origin: Made of US and non-US parts

Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage
<30 uA @ 30Vac/dc · When sensor contact is on (closed), resistance
0.26 ohm

RIBXGN SERIES SELECTION GUIDE

Model#

Sensing Range

Type Threshold

Sensor Contact Type

RIBXGNTF

.35-150 Amp Split Core Fixed, .35 Amp Solid State Switch SPST

Switching Voltage Range
30 Vac/dc

Maximum Switching Current
1 Amps Max

RIBXGNTA

.75-150 Amp Split Core Adjustable Solid State Switch SPST 30 Vac/dc 1 Amps Max

RIBXGNTF-125 .125-150 Amp Split Core Fixed, .125 Amp Solid State Switch SPST 30 Vac/dc 1 Amps Max

Sensor Contact Termination
Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire Terminal Strip, Accepts #14-22 AWG Wire

LED 1 Over Trip Point

LED 2 Under Trip Point

AC TRANSDUCERS

RIBXKTV Series
Current Transducers, Solid Core, Up to 100 Amps Sensing Range, 0-5 Vdc Terminal Strip Sensor Output
1.460"

.500" Diameter

1.863" 2.050"

1.008"

+

2.050"

­

Wire Clamp

Removable Mounting Tab

Output: Terminal Strip Accepts 14-22 AWG wire
SPECIFICATIONS

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 96.8% Full Scale Loading: RIBXKTV5-10, 1% Error @ 180 k RIBXKTV5-20, 1% Error @ 90 k RIBXKTV5-50, 1% Error @ 40 k RIBXKTV5-100, 1% Error @ 15 k
Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Type: Solid core with voltage output Origin: Made of US and non-US parts

RIBXKTV SERIES SELECTION GUIDE

Model#

Sensing Range

Sensor Output

RIBXKTV5-10 0-10 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire)

RIBXKTV5-20 0-20 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire)

RIBXKTV5-50 0-50 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire)

RIBXKTV5-100 0-100 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire)

90

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

AC TRANSDUCERS
RIBXK420 Series
Current Transducers, Solid Core, Up to 100 Amps Sensing Range, 4-20 mA Wire Lead Sensor Output
1.460"

CURRENT SENSORS

.500" Diameter

1.863"

Black (­) Red (+)

1.008" 2.050"

Wire Clamp

Removable Mounting Tab

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Wires: Red (positive) & Black (negative), 16, 18 AWG, 600V Rated Sensor Type: Internal, with 4-20 mA Transmitter Output Sensor Range: 0-20 Amps, 0-50 Amps, or 0-100 Amps (See Selection Guide Below) Accuracy: 96.4% FS Linearity: 99% FS (25%-100% Span)
Max Output Current: 30 mA Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Origin: Made of US and non-US parts

RIBXK420 SERIES SELECTION GUIDE

Model#

Sensing Range

Sensor Output

RIBXK420-20

0-20 Amps

Loop Powered 4-20 mA Transmitter (Pre-Wired)

RIBXK420-50

0-50 Amps

Loop Powered 4-20 mA Transmitter (Pre-Wired)

RIBXK420-100 0-100 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired)

AC TRANSDUCERS
RIBXGTV5-10
Current Transducer, Split Core, 0-10 Amp, 0-5 Vdc Terminal Output
Wire Clamp

Output Load Resistance
-
+

Supply Voltage
-+

RIBXK420 Red +
Black -

OUTPUT LOAD RESISTANCE
Maximum 700 ohms 600 ohms 500 ohms 400 ohms 300 ohms 250 ohms 200 ohms 100 ohms 50 ohms

SUPPLY VOLTAGE

Minimum Maximum

26 Vdc 24 Vdc 21 Vdc 19 Vdc 17 Vdc 16 Vdc 14 Vdc 12 Vdc 11 Vdc

35 Vdc 35 Vdc 35 Vdc 30 Vdc 30 Vdc 28 Vdc 28 Vdc 28 Vdc 28 Vdc

2.000"
.52" x .52" Opening for Wire Being Monitored
2.520"
1.100" 1.750"

2.000"

Output: Terminal Strip
Accepts 14-22 AWG wire

Removable Mounting Tab
SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 98.3% Full Scale Loading: 5% Error @ 58 k
Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Type: Split core with voltage output Origin: Made of US and non-US parts

Output Voltage (Vdc)

5

4

3

2

1

0

0

2

4

6

8

10

Input Current (A)

Idea l

Actual

(800) 888-5538 | www.functionaldevices.com

91

CURRENT SENSORS

AC TRANSDUCER
RIBXGTV5
Current Transducer, Split Core, Multi-Range (0-20 Amp, 50 Amp, 100 Amp), 0-5 Vdc Terminal Output
Wire Clamp

2.000"

.52" x .52" Opening for Wire Being Monitored
2.520"
1.100" 1.750"
Removable Mounting Tab

2.000"

Output: Terminal Strip
Accepts 14-22 AWG wire
DIP Switches

DIP SWITCH

1

2 Sensing Range

OFF OFF

0-20 Amp

OFF ON

0-50 Amp

ON OFF

0-100 Amp

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 98.3% Full Scale Loading: RIBXGTV5, (0-20 Amp), 5% Error @ 33 k RIBXGTV5, (0-50 Amp), 5% Error @ 15 k RIBXGTV5, (0-100 Amp), 5% Error @ 6.8 k
Max Sense Voltage: 600 Vac Origin: Made of US and non-US parts

Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Type: Split core with voltage output

AC TRANSDUCER
RIBXGTV10
Current Transducer, Split Core, Multi-Range (0-20 Amp, 50 Amp, 100 Amp), 0-10 Vdc Terminal Output
Wire Clamp

2.000"

.52" x .52" Opening for Wire Being Monitored
2.520"
1.100" 1.750"

2.000"

Output: Terminal Strip
Accepts 14-22 AWG wire
DIP Switches

DIP SWITCH

1

2 Sensing Range

OFF OFF OFF ON ON OFF

0-20 Amp 0-50 Amp 0-100 Amp

Removable Mounting Tab

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 98.8% Full Scale Loading: RIBXGTV10, (0-20 Amp), 5% Error @ 60.4 k RIBXGTV10, (0-50 Amp), 5% Error @ 25.24 k RIBXGTV10, (0-100 Amp), 5% Error @ 13.65 k
Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS

Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Sensor Type: Split core with voltage output Origin: Made of US and non-US parts

92

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

Output (mA) CURRENT SENSORS

AC TRANSDUCERS
RIBXG420 Series
Current Transducers, Split Core, Up to 100 Amps Sensing Range, 4-20 mA Wire Lead Sensor Output

Wire Clamp

2.520"

2.000"

1.100" 1.750"

.52" x .52" Opening for Wire Being Monitored
2.520"

Removable Mounting Tab

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Wires: Red (positive) & Black (negative), 16, 18 AWG, 600V Rated Sensor Type: Internal, with 4-20 mA Transmitter Output Sensor Range: 0-20 Amps, 0-50 Amps, or 0-100 Amps (See Selection Guide Below) Accuracy: Refer to chart below. Linearity: 99% FS (20%-100% Span)
Max Output Current: 30 mA Max Sense Voltage: 600 Vac Approvals: UL Listed, UL508, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.
Origin: Made of US and non-US parts

OUTPUT LOAD RESISTANCE
Maximum 800 ohms 500 ohms 350 ohms 250 ohms 200 ohms 100 ohms 50 ohms

SUPPLY VOLTAGE

Minimum 24 Vdc 18 Vdc 15 Vdc 13 Vdc 12 Vdc 10 Vdc 9 Vdc

Maximum 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc

RIBXG420 SERIES SELECTION GUIDE

Model#

Sensing Range

Sensor Output

RIBXG420-20

0-20 Amps

Loop Powered 4-20 mA Transmitter (Pre-Wired)

RIBXG420-50

0-50 Amps

Loop Powered 4-20 mA Transmitter (Pre-Wired)

RIBXG420-100

0-100 Amps

Loop Powered 4-20 mA Transmitter (Pre-Wired)

Span 20% ­ 100% 99% 99% 99%

ACCURACY
Span 10% ­ 100% 99% 97.5% 97%

Span 0% ­ 100% 95% 92% 91%

RIBXG420-20
20

IDEAL ACTUAL

Output Load Resistance
-
+

Supply Voltage
-+

RIBXG420 Red + Black -

16 8

7.5 12
7

6.5

8

6

5.5

4

5

0

4

8

12

16

20

4.5

Current (A)

4

0

1

2

3

4

(800) 888-5538 | www.functionaldevices.com

93

CURRENT SENSORS

AC TRANSDUCER

RIBXGT420-RMS
VFD Compatible True RMS Current Transducer, Split Core, Multi-Range (0-10, 20, and 50A),
4-20 mA Terminal Output

Wire Clamp

2.520"

2.000"

1.100" 1.750"

.52" x .52" Opening for Wire Being Monitored
2.520"

Removable Mounting Tab

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Sensor Type: Internal, with 4-20 mA Transmitter Output Sensor Range: 0-10 Amps, 0-20 Amps, or 0-50 Amps (See Selection Guide Below) Accuracy: ± 2% FS (5% - 100% Span)
Max Sense Voltage: 600 Vac Frequency: 10-400 Hz Approvals: UL Listed, UL508, C-UL, CE, RoHS
Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place.

OUTPUT LOAD RESISTANCE
Maximum 800 ohms 500 ohms 350 ohms 250 ohms 200 ohms 100 ohms 50 ohms

SUPPLY VOLTAGE

Minimum 24 Vdc 18 Vdc 15 Vdc 13 Vdc 12 Vdc 10 Vdc 9 Vdc

Maximum 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc

True RMS: True RMS current transducers can measure the current of waveforms that are not purely sinusoidal. This enables them to be used in applications involving VFDs, phase angle dimmers, switching power supplies and more.

DIP Switch 1 OFF OFF ON

DIP Switch 2 OFF ON OFF

Sensing Range 0-10A 0-20A 0-50A

IDEAL ACTUAL

Output Load Resistance
-
+

Supply Voltage
-+

RIBXGT420-RMS +
-

94

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

AC CURRENT SWITCHES
RIBXF
Current Switch, Fixed, 0.50-30 Amp, NEMA 1 Housing

RIBXA
Current Switch, Adjustable, 0.50-30 Amp, NEMA 1 Housing

Sensor Feedback Current Sensor Status
Not Used

Current Sensor Circuitry
Prp Prp

Sensor Feedback Current Sensor Status
Not Used

Current Sensor Circuitry
Prp Prp

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: Internal, with contact status

Sensor Threshold: Fixed, .5 Amps (RIBXF); Adjustable, .50-30 Amps (RIBXA)

Sensor Range: .50-30 Amps

Max Sense Voltage: 600 Vac

Sensor Contact Status: Current below threshold: Open / LED OFF

Current above threshold: Closed / LED ON

Sensor Contact:

· Solid State Contact

· When sensor contact is on (closed),

· 30 Vac/dc, .4 Amp Max.

voltage drop < .3 Vac/dc @ .1 Amp

· When sensor contact is off

< 1.6 Vac/dc @ .4 Amp

(open), leakage <30 uA @ 30Vac/dc

AC TRANSDUCER

RIBXV
Current Transducer, 0-30 Amp, Analog, 0-5 Vdc/0-10 Vdc Output, NEMA 1 Housing

Current Sensor Circuitry
Prp Prp

V V

0-10 Vdc 0-5 Vdc
Com

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1

Sensor Type: Internal, with voltage output Sensor Range: 0-30 Amps Max Sense Voltage: 600 Vac
Sensor Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/­ 3% full scale · Vripple < 10m Vac

AC CURRENT SWITCHES

RIBXRF
Current Switch, Solid Remote, Fixed, 1.25-150 Amp

RIBXRA
Current Switch, Solid Remote, Adjustable, 1.25-150 Amp

Sensor Contact

Current Sensor Circuitry

AXKT CT
Gry
Gry

Wire Being Monitored

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: External, with contact status Sensor Threshold: Fixed, 1.25 Amps (RIBXRF) Adjustable, 1.25-150 Amps (RIBXRA)

Sensor Range: 1.25-150 Amps Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open / LED OFF
Current above threshold: Closed / LED ON

Sensor Contact:

· Solid State Contact

· When sensor contact is on (closed),

· 30 Vac/dc, .4 Amp Max.

voltage drop < .3 Vac/dc @ .1 Amp

· When sensor contact is off

< 1.6 Vac/dc @ .4 Amp

(open), leakage <30 uA @ 30Vac/dc

(800) 888-5538 | www.functionaldevices.com

95

CURRENT SENSORS

CURRENT SENSORS

AC CURRENT SWITCH
RIBXJF
Current Switch, Split Ring Remote, Fixed, 3-150 Amp

Sensor Contact

Current

Sensor

Gry

Circuitry Gry

Wire Being Monitored
AXGT CT

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts
Remote Dimensions: (Outside) 2.52 x 2.00, (Inside) .52 x .52 Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: External, with contact status

Sensor Threshold: Fixed, 3 Amps Sensor Range: 3-150 Amps
Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open / LED OFF
Current above threshold: Closed / LED ON

Sensor Contact:

· Solid State Contact

· When sensor contact is on (closed),

· 30 Vac/dc, .4 Amp Max.

voltage drop < .3 Vac/dc @ .1 Amp

· When sensor contact is off

< 1.6 Vac/dc @ .4 Amp

(open), leakage <30 uA @ 30Vac/dc

AC CURRENT SWITCH
RIBXJA
Current Switch, Split Ring Remote, Adjustable, 3-150 Amp

Sensor Contact

Current

Sensor

Gry

Circuitry Gry

Wire Being Monitored
AXGT CT

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS UL Accepted for Use in Plenum, NEMA 1 Housing Rating: External, with contact status Sensor Type: Adjustable, 3-150 Amps Sensor Threshold: 3-150 Amps

Sensor Range: 600 Vac Max Sense Voltage: Current below threshold: Open / LED OFF Sensor Contact Status: Current above threshold: Closed / LED ON

Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc

· When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp

96

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAY & AC CURRENT SWITCH COMBO
RIBHX24BF
Current Switch and Relay Combination, 20 Amp SPST-N/O, Fixed, 24 Vac/dc Coil, NEMA 1 Housing

Gry Sensor Feedback Current Sensor Status
Gry
Wht/Yel 24 Vac/dc Wht/Yel

Org - C Org - N/O

RIBHX24BF-RD · Red housing
RIBHX24BF-N4 · NEMA 4X housing, UL508 only

CURRENT SENSORS

SPECIFICATIONS

Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated
Current Sensor Status Pink LED On = Current Over Trip Point (0.25 Amp) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple
Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts
Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp
Coil Current: 128 mA @ 24 Vac 71 mA @ 30 Vdc

Sensor Type: Internal, with contact status Sensor Threshold: Fixed, .25 Amp
Sensor Range: .25-20 Amps Sensor Feedback Output: Solid State Contact 30 Vac/dc, 100 mA

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac Pull In = 18 Vac

RELAY & AC CURRENT SWITCH COMBO

RIBHX24BA
Current Switch and Relay Combination, 20 Amp SPST-N/O, Adjustable, 24 Vac/dc Coil, NEMA 1 Housing
Gry Sensor Feedback Current Sensor Status
Gry

RIBHX24BA-RD · Red housing

Wht/Yel 24 Vac/dc Wht/Yel

Org - C Org - N/O

SPECIFICATIONS

Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red or Green LED On = Activated
Current Sensor Status Green LED On = Current Over Trip Point Adjustable Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50" NPT nipple
Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts
Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No

Contact Ratings:

Sensor Contact:

20 Amp Resistive @ 277 Vac

· When current sensor status is off (open), leakage

20 Amp Ballast @ 277 Vac

<30 uA @ 30Vac/dc

16 Amp Electronic Ballast @ 277 Vac (N/O) · When current sensor status is on (closed), voltage drop

10 Amp Tungsten @ 120 Vac (N/O)

< .3 Vac/dc @ .1 Amp

1,110 VA Pilot Duty @ 277 Vac

770 VA Pilot Duty @ 120 Vac

2 HP @ 277 Vac

Coil Current:

1 HP @ 120 Vac

128 mA @ 24 Vac

71 mA @ 30 Vdc

Sensor Type: Internal, with contact status

Sensor Threshold: Adjustable

Coil Voltage Input:

Sensor Range: .25-20 Amps

24 Vac ; 50-60 Hz

Sensor Feedback Output: Solid State Contact 30 Vac/dc, 100 mA

Drop Out = 3 Vac

Pull In = 18 Vac

(800) 888-5538 | www.functionaldevices.com

97

CURRENT SENSORS

RELAY & AC CURRENT SWITCH COMBOS

RIBXLC Series
Current Switches or Transducers with Relay, 5 or 10 Amp SPDT, 10-30 Vac/dc Coil, Fixed, Adjustable, or Analog, Up to 150 Amps Sensing Range,
Terminal Strip or Wire Lead Output

RIBXLCA, RIBXLCF, RIBXLCEA+

Sensor Feedback Current Sensor
Status
10-30 Vac/dc
Comm

Blu - N/C Yel - C
Org - N/O

RIBXLCV, RIBXLCEV^
10-30 Vac/dc Comm

V V

0-10 Vdc 0-5 Vdc
Com
Blu - N/C Yel - C
Org - N/O

RIBXLCRA, RIBXLCRF+

Sensor Feedback Current Sensor
Status 10-30 Vac/dc
Comm

Current Sensor Circuitry
Blu - N/C
Yel - C
Org - N/O

Wire Being Monitored
AXKT CT
Gry Gry

RIBXLCJA, RIBXLCJF+

Sensor Feedback Current Sensor
Status 10-30 Vac/dc
Comm

Current Sensor Circuitry
Blu - N/C
Yel - C
Org - N/O

Wire Being Monitored
AXGT CT
Gry Gry

RIBXLCA

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS UL Accepted for Use in Plenum, NEMA 1 Housing Rating: Yes Gold Flash: No Override Switch:

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc
Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

+ Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp
^ Sensor Feedback Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/­ 3% full scale · Vripple < 10m Vac
Notes: · Models AXKT and AXGT CT remotes do not have contact closure circuitry and only work in conjunction with RIBXLCR and RIBXLCJ models, respectively.

RIBXLC SERIES SELECTION GUIDE

Model#

Sensing Range

Type *

Threshold

Sensor Output

Remote Style

RIBXLCF ECMS .50-10 Amps

Internal w/ contact status

Fixed, .50 Amp

Solid State Contact 30 Vac/dc, 0.4 Amp

RIBXLCA ECMS .50-10 Amps

Internal w/ contact status

Adjustable

Solid State Contact 30 Vac/dc, 0.4 Amp

RIBXLCV

0-10 Amps

Internal w/ voltage output

Analog

0-5 Vdc 0-10 Vdc

RIBXLCRF ECMS1.25-150 Amps

External w/ contact status

Fixed, 1.25 Amp

Solid State Contact Model AXKT: (Solid 30 Vac/dc, 0.4 Amp Core Remote CT)

RIBXLCRA ECMS1.25-150 Amps

External w/ contact status

Adjustable

Solid State Contact Model AXKT: (Solid 30 Vac/dc, 0.4 Amp Core Remote CT)

RIBXLCJF ECMS 3-150 Amps

External w/ contact status

Fixed, 3 Amp

Solid State Contact Model AXGT: (Split 30 Vac/dc, 0.4 Amp Core Remote CT)

RIBXLCJA ECMS 3-150 Amps

External w/ contact status

Adjustable

Solid State Contact Model AXGT: (Split 30 Vac/dc, 0.4 Amp Core Remote CT)

RIBXLCEA

.125-5 Amps

Internal w/ contact status

Adjustable

Solid State Contact 30 Vac/dc, 0.4 Amp

RIBXLCEV

0-5 Amps

Internal w/ voltage output

Analog

0-5 Vdc 0-10 Vdc

* = Internal current sensor monitors current through common contact of relay.

Resistive 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp
5 Amp
5 Amp

Contact Ratings 10 Amp Resistive @ 120-277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)
5 Amp Resistive @ 277 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 268 VA Pilot Duty @ 277 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 175 VA Pilot Duty @ 277 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

98

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

CURRENT SENSORS

RELAY & AC CURRENT SWITCH COMBOS

RIBXLS Series
Current Switches or Transducers with Relay, 5 or 10 Amp SPST + Override, 10-30 Vac/dc Coil, Fixed,
Adjustable, or Analog, Up to 150 Amps Sensing Range, Terminal Strip or Wire Lead Output

RIBXLSA, RIBXLSF, (RIBXLSEA*)+

RIBXLSV, (RIBXLSEV*)^

Sensor Feedback Current Sensor
Status
10-30 Vac/dc
Comm

Selectable Jumper Wire Org*

CLOSED OPEN AUTO

Org*
*Org wires will be Gry

10-30 Vac/dc Comm

V V

0-10 Vdc 0-5 Vdc
Com Selectable Jumper Wire
Org*

CLOSED OPEN AUTO

Org*
*Org wires will be Gry

RIBXLSRA, RIBXLSRF+

Sensor Feedback Current Sensor
Status
10-30 Vac/dc

Current Sensor Circuitry
Selectable Jumper Wire Org

Comm

CLOSED Org OPEN AUTO

Wire Being Monitored
AXKT CT
Gry Gry

RIBXLSJA, RIBXLSJF+

Sensor Feedback Current Sensor
Status 10-30 Vac/dc
Comm

Current Sensor Circuitry
Selectable Jumper Wire Org
CLOSED Org OPEN AUTO

Wire Being Monitored
AXGT CT
Gry Gry

RIBXLSA

SPECIFICATIONS
# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc
Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

+ Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp
^ Sensor Feedback Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/­ 3% full scale · Vripple < 10m Vac
Notes: · Normally Open or Normally Closed selected by yellow jumper wire · Models AXKT and AXGT CT remotes do not have contact closure circuitry and only work in conjunction with RIBXLSR and RIBXLSJ models, respectively.

RIBXLS SERIES SELECTION GUIDE

Model#

Sensing Range

Type *

Threshold

Sensor Output

Remote Style

RIBXLSF ECMS

.50-10 Amps

Internal w/ contact status

Fixed, .50 Amp

Solid State Contact 30 Vac/dc, 0.4 Amp

RIBXLSA ECMS

.50-10 Amps

Internal w/ contact status

Adjustable

Solid State Contact 30 Vac/dc, 0.4 Amp

RIBXLSV

0-10 Amps

Internal w/ voltage output

RIBXLSRF ECMS 1.25-150 Amps

External w/ contact status

RIBXLSRA ECMS 1.25-150 Amps

External w/ contact status

Analog
Fixed, 1.25 Amp
Adjustable

0-5 Vdc 0-10 Vdc
Solid State Contact 30 Vac/dc, 0.4 Amp
Solid State Contact 30 Vac/dc, 0.4 Amp

Model AXKT: (Solid Core Remote)
Model AXKT: (Solid Core Remote)

RIBXLSJF ECMS

3-150 Amps

External w/ contact status

Fixed, 3 Amp

Solid State Contact 30 Vac/dc, 0.4 Amp

Model AXGT: (Split Core Remote)

RIBXLSJA ECMS 3-150 Amps

External w/ contact status

Adjustable

Solid State Contact Model AXGT: (Split 30 Vac/dc, 0.4 Amp Core Remote)

RIBXLSEA

.125-5 Amps

Internal w/ contact status

Adjustable

Solid State Contact 30 Vac/dc, 0.4 Amp

RIBXLSEV

0-5 Amps

Internal w/ voltage output

Analog

0-5 Vdc 0-10 Vdc

* = Internal current sensor monitors current through common contact of relay.

Resistive 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp

Contact Ratings
10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

10 Amp

10 Amp 5 Amp 5 Amp

5 Amp Resistive @ 277 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 268 VA Pilot Duty @ 277 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 175 VA Pilot Duty @ 277 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C)

(800) 888-5538 | www.functionaldevices.com

99

CURRENT SENSORS

RELAY & AC CURRENT SWITCH COMBOS

RIBX24 Series
Current Switches or Transducers with Relay, 20 Amp SPDT or SPST + Override, 24 Vac/dc Coil, Fixed,
Adjustable, or Analog, Up to 150 Amps Sensing Range, Terminal Strip or Wire Lead Output

RIBX24BA, RIBX24BF+

RIBX24BV^

Sensor Feedback Current Sensor Status

24 Vac/dc Comm

Blu - N/C Yel - C
Org - N/O

RIBX24SBA, RIBX24SBF+

Sensor Feedback Current Sensor Status
24 Vac/dc Comm

Selectable Jumper Wire Org

CLOSED

Org

OPEN

AUTO

24 Vac/dc Comm
RIBX24SBV^
24 Vac/dc Comm

V V
V V

0-10 Vdc 0-5 Vdc
Com Blu - N/C
Yel - C Org - N/O

0-10 Vdc 0-5 Vdc
Com

Selectable Jumper Wire Org

CLOSED

Org

OPEN

AUTO

SPECIFICATIONS
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple
Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts
Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

RIBX24SBA
Sensor Contact: + · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Sensor Feedback Output: ^ · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/­ 1% full scale · Vripple < 10m Vac

RIBX24 SERIES SELECTION GUIDE

Model#

Sensing Range

Type * Threshold Sensor Output Resistive

RIBX24BF ECMS

.50-20 Amps

Internal w/ contact status

Fixed, .50 Amp

Solid State Contact 30 Vac/dc, 0.4 Amp

20 Amp

RIBX24BA ECMS

.50-20 Amps

Internal w/ contact status

Adjustable

Solid State Contact 30 Vac/dc, 0.4 Amp

20 Amp

RIBX24BV

0-20 Amps

Internal w/ voltage output

Analog

0-5 Vdc 0-10 Vdc

20 Amp

RIBX24SBF ECMS

.50-20 Amps

Internal w/ contact status

Fixed, .50 Amp

Solid State Contact 30 Vac/dc, 0.4 Amp

20 Amp

RIBX24SBA ECMS

.50-20 Amps

Internal w/ contact status

Adjustable

Solid State Contact 30 Vac/dc, 0.4 Amp

20 Amp

RIBX24SBV

0-20 Amps

Internal w/ voltage output

Analog

0-5 Vdc 0-10 Vdc

20 Amp

Override Switch
No No No Yes Yes Yes

Contact Ratings

Notes

20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

· Normally Open or Normally Closed selected by yellow jumper wire

* = Internal current sensor monitors current through common contact of relay.

100

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

DIN MOUNT NO SOCKET RELAY & AC CURRENT SWITCH COMBO
RIBRXLCF-NS
Current Switch and Relay Combination, 10 Amp SPST-N/O, 10-30 Vac/dc Coil, Fixed, 0.25-10 Amp, No Socket Non-Pluggable Relay

C NO
CURRENT SENSORS

10-30 Vac/dc

Sensor Feedback Current Sensor Status
N/O

Current Status
Relay LED Pink Current Status

ADIN35ES Pair of End Stops for 35mm DIN Rail

10-30V COM

Comm C
SPECIFICATIONS

Open Lid this Side

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information.

# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Sensing Range: .25 - 10A Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac 1/3 HP @ 120-240 Vac 1/4 HP @ 277 Vac
Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Sensor Contact: Solid State Contact 30Vac/dc, 0.1A Max.
· When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp

DIN MOUNT NO SOCKET RELAY & AC CURRENT SWITCH COMBO

RIBRXLSA-NS
Current Switch and Relay Combination, 10 Amp SPST-N/O + Coil Side Override,
10-30 Vac/dc Coil, Fixed, 0.25-10 Amp, No Socket Non-Pluggable Relay

PWR Closed
CTRL Open Auto

Sensor Feedback Current Sensor Status
N/O

PWR CTRL COM
CLOSED OPEN AUTO

Override Switch

Current Status

Relay LED Pink Current Status

Apply Continuous Power(10-30Vac/dc) to PWR and COM.

C NO
ADJ. CURR STAT

ADIN35ES Pair of End Stops for 35mm DIN Rail

Comm C
SPECIFICATIONS

Apply Coil Control(10-30Vac/dc) to CTRL and COM.

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information.

# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Sensing Range: .25 - 10A Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac 1/3 HP @ 120-240 Vac 1/4 HP @ 277 Vac
Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Sensor Contact: Solid State Contact 30Vac/dc, 0.1A Max.
· When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp

(800) 888-5538 | www.functionaldevices.com

101

DIN MOUNT RELAY & AC CURRENT SWITCH COMBO
RIBRXLCF
Current Switch and Relay Combination, 10 Amp SPST-N/O, 10-30 Vac/dc Coil, Fixed, 0.25-10 Amp

CURRENT SENSORS
C NO

10-30 Vac/dc

Sensor Feedback Current Sensor Status
N/O

Current Status
Relay LED Pink Current Status

ADIN35ES Pair of End Stops for 35mm DIN Rail

10-30V COM

Comm C
SPECIFICATIONS

Open Lid this Side

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information.

# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Sensing Range: .25 - 10A
Replacement Relay: ARL1C Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac 1/3 HP @ 120-240 Vac 1/4 HP @ 277 Vac
Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Sensor Contact: Solid State Contact 30Vac/dc, 0.1A Max.
· When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp

DIN MOUNT RELAY & AC CURRENT SWITCH COMBO
RIBRXLSA
Current Switch and Relay Combination, 10 Amp SPST-N/O + Coil Side Override, 10-30 Vac/dc Coil, Adjustable, 0.25-10 Amp

PWR Closed
CTRL Open Auto
Comm

Sensor Feedback Current Sensor Status
N/O
C

PWR CTRL COM
CLOSED OPEN AUTO

Override Switch

Current Status

Relay LED Pink Current Status

Open Lid this Side

Apply Continuous Power(10-30Vac/dc) to PWR and COM.
Apply Coil Control(10-30Vac/dc) to CTRL and COM.

SPECIFICATIONS

C NO
ADJ. CURR STAT

ADIN35ES Pair of End Stops for 35mm DIN Rail

ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

Models ADIN35 and ADIN35ES sold separately. See data sheet on website for more product information.

# Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.76"H x 3.88"W x 0.78"D Housing Detail: See Housing K in housing guide for dimensions Origin: Made of US and non-US parts Terminal Strip: 14-22 AWG wire Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: Yes Sensing Range: .25 - 10A
Replacement Relay: ARL1C Accessories: ADIN35, ADIN35ES

Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240/277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac 1/3 HP @ 120-240 Vac 1/4 HP @ 277 Vac
Power and Control Voltage: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc

Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac

13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc

Sensor Contact: Solid State Contact 30Vac/dc, 0.1A Max.
· When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp

102

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAY & AC CURRENT SWITCH COMBO
RIBX243PV
Transducer and Relay Combination, 20 Amp 3PST-N/O, 24 Vac/dc Coil, Analog, 0-20 Amp, 0-10 Vdc Output, NEMA 1 Housing
Blu - N/O Blu - N/O
Yel - N/O Yel - N/O

CURRENT SENSORS

V

24 Vac/dc Comm Com 0-10 Vdc

Org - N/O Org - N/O

SPECIFICATIONS

# Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc

Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

RELAY & AC CURRENT SWITCH COMBO

RIBX243PF
Current Switch and Relay Combination, 20 Amp 3PST-N/O,
24Vac/dc Coil, Internal Fixed, 0.5-20 Amp, NEMA 1 Housing

Blu - N/O Blu - N/O

Sensor Type: Internal, with voltage output. Current sensing on orange wires
Sensor Range: 0-20 Amps
Sensor Feedback Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/­ 1% full scale · Vripple < 10m Vac
Notes: · Order Normally Closed by adding "-NC" to end of model number · Can be ordered with 0-5 Vdc voltage output Consult factory.

Yel - N/O Yel - N/O

24 Vac/dc Comm Sensor Feedback Current Sensor Status (Orange WIres)

Org - N/O Org - N/O

SPECIFICATIONS

# Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc

Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

Sensor Type: Internal, with contact status Current sensing on orange wires
Sensor Threshold: Fixed, .5 Amps Sensor Range: .50-20 Amps
Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp
Notes: · Order Normally Closed by adding "-NC" to end of model number

(800) 888-5538 | www.functionaldevices.com

103

CURRENT SENSORS

RELAY & AC CURRENT SWITCH COMBO
RIBX243PA
Current Switch and Relay Combination, 20 Amp 3PST-N/O, 24Vac/dc Coil, Internal Adjustable, 0.5-20 Amp, NEMA 1 Housing
Blu - N/O Blu - N/O

Yel - N/O Yel - N/O

24 Vac/dc Comm Sensor Feedback Current Sensor Status (Orange WIres)

Org - N/O Org - N/O

SPECIFICATIONS
# Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No

Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc

Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc

Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase

Sensor Type: Internal, with contact status Current sensing on orange wires
Sensor Threshold: Adjustable, .50-20 Amps Sensor Range: .50-20 Amps
Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp
Notes: · Order Normally Closed by adding "-NC" to end of model number

104

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

CURRENT SENSORS

RELAY & AC CURRENT SWITCH COMBOS

RIBMX24 Series
Current Switches or Transducers with Relay, 20 Amp SPDT or SPST + Override, 24 Vac/dc Coil, Fixed, Adjustable,
or Analog, Up to 150 Amps Sensing Range, Terminal Strip, 4.00" Track Mount

RIBMX24BA, RIBMX24BF+

RIBMX24SBV^

Sensor Feedback Current Sensor Status
C 24 Vac/dc
N/O
Comm N/C

0-10 Vdc V
0-5 Vdc V
Comm
24 Vac/dc
Comm

Selectable Jumper Wire Not Used
CLOSED OPEN AUTO

RIBMX24SBA, RIBMX24SBF+

Sensor Feedback Current Sensor Status
24 Vac/dc Comm

Selectable Jumper Wire Not Used
CLOSED OPEN AUTO

SPECIFICATIONS
Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: Red LED On = Activated Dimensions: 2.95"H x 4.00"W x 1.25"D1/1.75"D2
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 4.000, MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No

Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc
Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc

Sensor Contact: + · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp
Sensor Feedback Output: ^ · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/­ 1% full scale · Vripple < 10m Vac

RIBMX24 SERIES SELECTION GUIDE

Model#

Sensing Range

RIBMX24BF ECMS

.50-20 Amps

RIBMX24BA ECMS

.50-20 Amps

Type*
Internal w/ contact status
Internal w/ contact status

Threshold

Sensor Output

Resistive

Override Switch

Fixed, .50 Amp

Solid State Contact 30 Vac/dc, 0.4 Amp

20 Amp

No

Adjustable

Solid State Contact 30 Vac/dc, 0.4 Amp

20 Amp

No

Contact Type SPDT
SPDT

Contact Ratings
20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

Notes

RIBMX24SBF ECMS

.50-20 Amps

Internal w/ contact status

Fixed, .50 Amp

Solid State Contact 30 Vac/dc, 0.4 Amp

20 Amp

Yes

RIBMX24SBA ECMS

.50-20 Amps

Internal w/ contact status

Adjustable

Solid State Contact 30 Vac/dc, 0.4 Amp

20 Amp

Yes

RIBMX24SBV

Internal w/ 0-20 Amps voltage
output

Analog

0-5 Vdc 0-10 Vdc

20 Amp Yes

* = Internal current sensor monitors current through common contact of Relay

SPST SPST SPST

20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac

· Normally Open or Normally Closed selected by yellow jumper wire

(800) 888-5538 | www.functionaldevices.com

105

AC & DC POWER SUPPLIES

POWER SUPPLIES

PSH100A100AB10

PSH300A-LVC

PSH40AB10

PSM19A24DAS

PSMN40A24DS

PSP24DA

AC & DC POWER SUPPLIES

· 40 - 500 VA AC models · Single & dual transformers · Prepackaged power supply kits

· Class 2 models · On/off control · Overcurrent protection

· LED power indicator · High/low voltage separation · 120 Vac convenience outlets

500, 300 & 200 VA Power Supplies are Perfect for VAV & Zone and Network Controller Applications

· 5 or 3 isolated 100 VA or 5 isolated 40 VA outputs · On/Off circuit breaker switch for each output · UL Listed Class 2

· Enclosed or sub-panel mount · Low voltage compartment models available · 120 Vac convenience outlet available

Mounting Your Controller and Peripheral Devices is Easy and Convenient in our Prepackaged Power Supply Solutions
Metal Enclosure, Power Supply, and Sub-Panel with Several Options to Fit Your Needs
If you plan to install a controller and other peripheral devices, an important consideration is where the items will be placed within an enclosure and how they will be powered. We have a line of products that can address both of those needs: the MHP Series. These products include a metal enclosure, power supply and a sub-panel with several prepackaged options to meet your specific needs.

106

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER SUPPLIES

AC POWER SUPPLIES

AC POWER SUPPLIES: 40-100 VA

MODEL # PSB40AB10

TRANSFORMER(S)

·

40 VA

INPUT POWER 120 Vac

AUX

120 VAC OUTPUT MAIN BREAKER ON SECONDARY EXTENSION HOUSING STYLE / SPEC

HEIGHT WIDTH DEPTH OUTLETS WIRE INPUT POWER * CONFIGURATION CORD TRACK MOUNT PAGE

5.200 5.250 3.750 ·

· 10 A Switch/Breaker Ext. Terminal Strip

Panel Mount 109

PSB100AB10 PSC40AB10

·

100 VA

·

40 VA

120 Vac 120 Vac

5.200 5.250 3.750 · 6.250 5.620 3.900 ·

· 10 A Switch/Breaker Ext. Terminal Strip · 10 A Switch/Breaker Ext. Terminal Strip

Panel Mount 109

Enclosed

109

PSC100AB10 PSMN40A

·

100 VA

·

40 VA

120 Vac 120 Vac

6.250 5.620 3.900 ·
3.250 2.750 2.000

· 10 A Switch/Breaker Ext. Terminal Strip
Terminal Strip

Enclosed

109

MT212-4 included 110

PSMN40AS

·

40 VA

120 Vac

3.250 2.750 2.000

Terminal Strip

MT212-4 included 110

PSH40A

·

40 VA

120 Vac

4.500 5.438 4.500 ·

Ext. Terminal Strip

Enclosed

110

PSH40AW

·

40 VA

120 Vac

4.500 5.438 4.500 ·

Internal Wires

Enclosed

110

PSH40AB10

·

40 VA

120 Vac

4.500 5.438 4.500 ·

· 10 A Switch/Breaker Ext. Terminal Strip

Enclosed

110

PSH40AB10-EXT2 ·

40 VA

120 Vac

4.500 5.438 4.500 ·

· 10 A Switch/Breaker Ext. Terminal Strip ·

Enclosed

111

PSH40AWB10 PSH75A

·

40 VA

120 Vac

4.500 5.438 4.500 ·

· 10 A Switch/Breaker Internal Wires

·

75 VA

480/277/240/208/120 Vac 4.500 5.438 4.500 ·

Ext. Terminal Strip

Enclosed

110

Enclosed

111

PSH75AW PSH75AB10

·

75 VA

480/277/240/208/120 Vac 4.500 5.438 4.500 ·

Internal Wires

·

75 VA

480/277/240/208/120 Vac 4.500 5.438 4.500 ·

· 10 A Switch/Breaker Ext. Terminal Strip

Enclosed

111

Enclosed

111

PSH75AWB10 PSH100A

·

75 VA

480/277/240/208/120 Vac 4.500 5.438 4.500 ·

·

100 VA

120 Vac

4.500 5.438 4.500 ·

· 10 A Switch/Breaker Internal Wires
Ext. Terminal Strip

Enclosed

111

Enclosed

112

PSH100AW

·

100 VA

120 Vac

4.500 5.438 4.500 ·

Internal Wires

Enclosed

112

PSH100AB10

·

100 VA

120 Vac

4.500 5.438 4.500 ·

· 10 A Switch/Breaker Ext. Terminal Strip

Enclosed

112

PSH100AB10-EXT2 ·

100 VA

120 Vac

4.500 5.438 4.500 ·

· 10 A Switch/Breaker Ext. Terminal Strip ·

Enclosed

111

PSH100AWB10 PSH75A75A

·

100 VA

120 Vac

4.500 5.438 4.500 ·

· 75 VA, 75 VA 480/277/240/208/120 Vac 4.500 8.625 4.500 ·

· 10 A Switch/Breaker Internal Wires
Ext. Terminal Strip

Enclosed

112

Enclosed

112

PSH75A75AW PSH75A75AB10

· 75 VA, 75 VA 480/277/240/208/120 Vac 4.500 8.625 4.500 · · 75 VA, 75 VA 480/277/240/208/120 Vac 4.500 8.625 4.500 ·

Internal Wires
· 10 A Switch/Breaker Ext. Terminal Strip

Enclosed

112

Enclosed

112

PSH75A75AWB10 · 75 VA, 75 VA 480/277/240/208/120 Vac 4.500 8.625 4.500 ·

PSH100A100A

· 100 VA, 100 VA

120 Vac

4.500 8.625 4.500 ·

· 10 A Switch/Breaker Internal Wires
Ext. Terminal Strip

Enclosed

112

Enclosed

113

PSH100A100AW

· 100 VA, 100 VA

120 Vac

4.500 8.625 4.500 ·

Internal Wires

Enclosed

113

PSH100A100AB10 · 100 VA, 100 VA

120 Vac

4.500 8.625 4.500 ·

· 10 A Switch/Breaker Ext. Terminal Strip

Enclosed

113

PSH100A100AWB10 · 100 VA, 100 VA

120 Vac

4.500 8.625 4.500 ·

· 10 A Switch/Breaker Internal Wires

Enclosed

113

AC POWER SUPPLIES: 200-500 VA

MODEL # PSH500A PSH300A PSH200A PSMN500A PSMN300A PSMN200A

TRANSFORMER

INPUT POWER

120 VAC BREAKER PER SECONDARY

HOUSING STYLE /

SPEC

HEIGHT WIDTH DEPTH OUTLET# OUTPUT CONFIGURATION

SUB-PANEL

PAGE

· 500 VA (five 100 VA Outputs) 480/277/240/120 Vac 12.125 12.125 6.000

5 x 4 Amp

Terminals

Enclosed

113

· 300 VA (three 100 VA Outputs) 480/277/240/120 Vac 12.125 12.125 6.000

3 x 4 Amp

Terminals

Enclosed

114

· 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac 12.125 12.125 6.000

5 x 2 Amp

Terminals

Enclosed

114

· 500 VA (five 100 VA Outputs) 480/277/240/120 Vac 11.330 11.400 5.000

5 x 4 Amp

Terminals

Sub-panel Mount

113

· 300 VA (three 100 VA Outputs) 480/277/240/120 Vac 11.330 11.400 5.000

3 x 4 Amp

Terminals

Sub-panel Mount

114

· 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac 11.330 11.400 5.000

5 x 2 Amp

Terminals

Sub-panel Mount

114

PSH500A-LVC · 500 VA (five 100 VA Outputs) 480/277/240/120 Vac 12.125 12.125 6.000

5 x 4 Amp

Terminals

Enclosed with Low Voltage Compartment

115

PSH300A-LVC · 300 VA (three 100 VA Outputs) 480/277/240/120 Vac 12.125 12.125 6.000

3 x 4 Amp

Terminals

Enclosed with Low Voltage Compartment

115

PSH200A-LVC · 200 VA (five 40 VA Outputs) 480/347/277/240/120 Vac 12.125 12.125 6.000

5 x 2 Amp

Terminals

Enclosed with Low Voltage Compartment

116

PSH500AB10-LVC · 500 VA (five 100 VA Outputs)

120 Vac

12.125 12.125 6.000 ·

5 x 4 Amp

Terminals

Enclosed with Low Voltage Compartment

117

PSH300AB10-LVC · 300 VA (three 100 VA Outputs)

120 Vac

12.125 12.125 6.000 ·

3 x 4 Amp

Terminals

Enclosed with Low Voltage Compartment

118

PSH200AB10-LVC · 200 VA (five 40 VA Outputs)

120 Vac

12.125 12.125 6.000 ·

5 x 2 Amp

Terminals

Enclosed with Low Voltage Compartment

118

= Class 2 UL Listed - see data sheet for specific Listing

* = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A

# = Convenience outlet has 4 Amp Breaker

(800) 888-5538 | www.functionaldevices.com

107

AC & DC POWER SUPPLIES

POWER SUPPLIES

AC POWER SUPPLY PREPACKAGED KITS

MODEL # CTRL-PS

AUX

SUB-PANEL /

TRANS-

INPUT

120 VAC OUTPUT ON/OFF MAIN BREAKER ON SECONDARY

METAL

TRACK

SPEC

FORMER(S) POWER HEIGHT WIDTH DEPTH OUTLETS WIRE SWITCH INPUT POWER * CONFIGURATION HOUSING MOUNT

PAGE

40 VA

120 Vac 14.500 7.700 3.900

·

MH1000

MT212-4 included

120

MHP3903100AB10

100 VA 120 Vac 12.500 24.500 6.500 ·

·

·

10 A Switch/Breaker Ext. Terminal Strip

MH3900

SP3803S (Polymetal)

120

MHP3903100A100AB10 100 VA, 100 VA 120 Vac 12.500 24.500 6.500 ·

·

·

10 A Switch/Breaker Ext. Terminal Strip

MH3900

SP3803S (Polymetal)

121

MHP3904100AB10

100 VA 120 Vac 12.500 24.500 6.500 ·

·

·

10 A Switch/Breaker

Ext. Terminal Strip

MH3900

SP3804S (Perforated)

120

MHP3904100A100AB10 100 VA, 100 VA 120 Vac 12.500 24.500 6.500 ·

·

·

10 A Switch/Breaker

Ext. Terminal Strip

MH3900

SP3804S (Perforated)

121

MHP4604100AB10

100 VA 120 Vac 16.150 20.000 6.720 ·

·

·

10 A Switch/Breaker

Ext. Terminal Strip

MH4600

SP4604 (Perforated)

121

MHP4604100A100AB10 100 VA, 100 VA 120 Vac 16.150 20.000 6.720 ·

·

·

10 A Switch/Breaker

Ext. Terminal Strip

MH4600

SP4604 (Perforated)

122

DC POWER SUPPLIES

MODEL #

VOLTAGE INPUT

VOLTAGE OUTPUT

OUTPUT ON/OFF

HOUSING STYLE / SPEC

CURRENT SWITCH HEIGHT WIDTH DEPTH TRACK MOUNT PAGE

PSP24DA

·

24 Vac

Adjustable 1.5-28 Vdc ; Non-Isolated 300 mA

2.390 3.310 1.810

Enclosed

122

PSH24DWB10

120 Vac

Fixed 24 Vdc ; Isolated

2.5 Amp

·

4.500 5.438 4.500

Enclosed

123

PSH100A24DWB10

120 Vac

Fixed 24 Vdc ; Isolated 100 VA, 24 Vac 2.5 Amp

·

4.500 8.625 4.500

Enclosed

123

PSMN24DA

·

24 Vac

Adjustable 1.5-28 Vdc ; Non-Isolated 300 mA

1.750 2.750 1.750 MT212-2 included 124

PSMN24DAS

·

24 Vac

Adjustable 1.5-28 Vdc ; Non-Isolated 300 mA

·

1.750 2.750 1.750 MT212-2 included 124

PSM20A12DAS

·

24 Vac

Adjustable 1.5-14 Vdc ; Isolated 300 mA

·

2.750 4.000 2.250 MT212-4 included 124

PSM24A24DAS

·

24 Vac

Adjustable 1.5-28 Vdc ; Isolated 300 mA

·

2.750 4.000 2.250 MT212-4 included 125

PSM19A24DAS

·

120 Vac

Adjustable 1.5-28 Vdc ; Isolated 300 mA

·

2.750 4.000 2.250 MT212-4 included 125

PSMN40A24DS

·

120 Vac

Fixed 24 Vdc ; Isolated

1 Amp

·

5.000 2.750 2.500 MT212-6 included 125

PSH100AB10-DC

·

120 Vac

Fixed 24 Vdc ; Isolated

2.5 Amp

·

4.500 5.438 4.500

Enclosed

126

PSH100A100AB10-DC ·

120 Vac

Fixed 24 Vdc ; Isolated ; 100 VA, 24 Vac 2.5 Amp

·

4.500 8.625 4.500

Enclosed

126

DIN MOUNT DC POWER SUPPLIES

MODEL # PULS-ML15-241 PULS-PIC120-241D PULS-PIC240-241D PULS-PIM36-241 PULS-PIM60-241 PULS-PIM60-245 PULS-PIM90-241 PULS-PIM90-245 PULS-PIM90-245-L1

VOLTAGE INPUT

·

100-240 Vac

· 100-120Vac; 200-240Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

·

100-240 Vac

VOLTAGE OUTPUT Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated Adjustable 24-28 Vdc ; Isolated

OUTPUT CURRENT
600 mA 5 Amp 10 Amp 1.5 Amp 2.5 Amp 2.5 Amp 3.8 Amp 3.8 Amp 3.8 Amp

ON/OFF SWITCH

HEIGHT 2.950 4.880 4.880 3.540" 3.540" 3.540" 3.540" 3.540" 3.540"

WIDTH 0.890 1.540 1.930" 0.860" 1.420" 1.420" 1.420" 1.420" 1.420"

DEPTH 3.580 4.880 4.880 3.580" 3.580" 3.580" 3.580" 3.580" 3.580"

HOUSING STYLE / TRACK MOUNT
DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount DIN Mount

For full product information on "PULS-" models, see our website for data sheets pages.

= Class 2 UL Listed - see data sheet for specific Listing

* = Kills power to entire unit: Outlets, Aux. Output, & Transformer; Total Combined Output 9A

108

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER SUPPLIES

AC POWER SUPPLYIE: S1:21020VAVCACTOTO2424VAVCAC

PSB40AB10
Single 40 VA Power Supply, 120 Vac to 24 Vac, 10 Amp Main
Breaker, Open Bracket Panel Mount

PSB100AB10
Single 100 VA Power Supply, 120 Vac to 24 Vac, 10 Amp Main
Breaker, Open Bracket Panel Mount

120 Vac Convenience Outlet *
Neutral 120 Vac

Ground 120 Vac Aux. Output

2.250"

2.250"

3.750"

ON RESET
OFF
OFF

LED Indicator

Com

24 Vac

10 Amp Main Breaker/Switch

24 Vac Breaker

24 Vac On/O Switch

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

4.610"

ON RESET
OFF

OFF

5.250"

5.200"

SPECIFICATIONS
Transformer: One 40 VA Split-Bobbin (PSB40AB10) One 100 VA Split-Bobbin (PSB100AB10)
Primary: 120 Vac Secondary: 24 Vac, w/ LED Indicator Frequency: 50/60 Hz Over Current Protection: Inherently Limited + Circuit Breaker (PSB40AB10)
Circuit Breaker (PSB100AB10) 24 Vac ON/OFF: On / Off Switch Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A

Class 2
REMOVABLE TERMINAL COVER PROVIDED
Mounting: Panel mount Max. Ambient Temperature: 40° C
Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508, C-UL, CE, RoHS
Dimensions: 5.200 H x 5.250 W x 3.750 D Origin: Made of US and non-US parts

AC POWER SUPPLYIE: S1:21020VAVCACTOTO2424VAVCAC

PSC40AB10
Single 40 VA Power Supply, 120 Vac to 24 Vac, 10 Amp
Main Breaker, Metal Enclosure

PSC100AB10
Single 100 VA Power Supply, 120 Vac to 24 Vac, 10 Amp
Main Breaker, Metal Enclosure

120 Vac Convenience Outlet *
Neutral 120 Vac

Ground 120 Vac Aux. Output

5.620" 2.245"

3.900"

ON RESET
OFF
OFF

LED Indicator

Com

24 Vac

10 Amp Main Breaker/Switch

24 Vac Breaker

24 Vac On/O Switch

Removable Access Plate

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

5.620"

6.250" 4.500"

Shown Without Cover

Class 2 Shown With Cover

SPECIFICATIONS

Transformer: One 40 VA Split-Bobbin, Inherently Limited (PSC100AB10) One 100 VA Split-Bobbin, Circuit Breaker (PSC100AB10)
Primary: 120 Vac Secondary: 24 Vac, w/ LED Indicator Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker

Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A
Mounting: Mounting plate included (as shown) Max. Ambient Temperature: 40° C
Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS
Dimensions: 6.250 H x 5.620 W x 3.900 D Origin: Made of US and non-US parts

Notes: · To order without enclosure, see PSB40AB10 · To order without enclosure, see PSB100AB10.

(800) 888-5538 | www.functionaldevices.com

109

AC POWER SUPPLIES: 120 VAC TO 24 VAC

PSMN40A
40 VA Power Supply, 120 Vac to 24
Vac, 2.75" Track Mount

PSMN40AS
40 VA Power Supply, 120 Vac to 24
Vac, Switch, 2.75" Track Mount

LOAD 24 Vac

LOAD 24 Vac

POWER SUPPLIES

Switch: On / O

LINE 120 Vac

LINE 120 Vac

SPECIFICATIONS
Transformers: One 40 VA Primary: 120 Vac
Secondary: 24 Vac, isolated Frequency: 50/60 Hz Overload Protection: Inherently limited Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Secondary Voltage Present Dimensions: 3.25" H x 2.75"W x 2.00" D1/2.50" D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: MT212-4 Mounting Track Supplied ON/OFF Switch: 2 Position (PSMN40AS) Max. Ambient Temperature: 40° C Approvals: UL916, UL508, C-UL, CE, RoHS
Origin: Made of US and non-US parts

Class 2

AC POWER SUPPLIES
PSH40A Series
Single 40 VA Power Supply, 120 Vac to 24 Vac, UL Class 2, Metal Enclosure

120 Vac Convenience Outlet *

24 Vac Breaker

24 Vac

ON OFF

On/O Switch

RESET

LED

Indicator

OFF

5.438" 5.150"

ON 4.500"

RESET

OFF

4.250"

OFF

4.500"

Com

24 Vac

120 Vac Convenience Outlet *

10 Amp Main Breaker/Switch

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

SPECIFICATIONS

5.150"

PSH40A SERIES SELECTION GUIDE

Model #
PSH40A PSH40AW PSH40AB10* PSH40AWB10*

120 Vac Outlets
· · · ·

Aux Output Wire
· ·

Main Breaker on Input Power
10 Amp Switch / Breaker 10 Amp Switch / Breaker

Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires

Class 2

Transformer: One 40 VA Split-Bobbin Over Current Protection: Circuit Breaker
Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508, C-UL, CE, RoHS, ^ Special Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts

Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac

All Other Models Primary Wires BLK: 120 Vac WHT: Common
"W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common

Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^
https://hcai.ca.gov/wp-content/
uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling

110

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER SUPPLIES

AC POWER SUPPLIES

PSH40AB10-EXT2
Single 40 VA Power Supply, 120 Vac to 24 Vac, UL
Class 2, 10 Amp Main Breaker with Extension Cord,
Metal Enclosure

Extension Cord

120 Vac Convenience Outlet *

PSH100AB10-EXT2
Single 100 VA, 120 Vac to 24 Vac, UL Class 2,
10 Amp main breaker with input extension cord,
Metal Enclosure

24 Vac Breaker

24 Vac

ON OFF

On/O Switch

RESET

LED

Indicator

OFF

36.000"

Com

24 Vac

120 Vac Convenience Outlet *

10 Amp Main Breaker/Switch

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

5.438" 5.150"

ON 4.500"

RESET

OFF

4.250"

OFF

5.150"

4.500"

SPECIFICATIONS

Class 2
PLUGS DIRECTLY INTO WIRED OUTLET BOX FOR USE ABOVE FALSE CEILINGS OR IN CONTROL PANELS

Transformer: One 40 VA (PSH40A10-EXT2) One 100 VA (PSH100A10-EXT2)
Over Current Protection: Circuit Breaker Frequency: 50/60 Hz
24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500H x 5.438 W x 4.500 D Origin: Made of US and non-US parts

Input Wires: Powercord BLK: 120 Vac WHT: Neutral GRN: Ground

Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time.

Output Wire: Auxiliary Load Output BLU: 120 Vac 9 Amp, max.

AC POWER SUPPLIES

PSH75A Series
Single 75 VA Power Supply Multi-
tap 480/277/240/208/120 to 24
Vac, UL Class 2, Metal Enclosure

120 Vac Convenience Outlet *

5.438" 5.150"

4.500"

24 Vac Breaker

24 Vac

ON OFF

On/O Switch

RESET

RESET

LED

Indicator OFF OFF

ON 4.500"

OFF

4.250"

Com

24 Vac

120 Vac Convenience Outlet *

10 Amp Main Breaker/Switch

5.150"

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

SPECIFICATIONS

Transformer: One 75 VA Split-Bobbin Over Current Protection: Circuit Breaker
Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts

PSH75A SERIES SELECTION GUIDE

Model #

120 Vac Aux Output Outlets Wire

Main Breaker on Input Power

PSH75A

·

PSH75AW

·

PSH75AB10*

·

·

10 Amp Switch / Breaker

PSH75AWB10* ·

·

10 Amp Switch / Breaker

Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires

Class 2

Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac

All Other Models Primary Wires** GRY: 480 Vac BRN: 277 Vac ORG: 240 Vac RED: 208 Vac WHT: 120 Vac BLK: Common
"W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common

Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^
https://hcai.ca.gov/wp-content/
uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling

(800) 888-5538 | www.functionaldevices.com

111

AC POWER SUPPLIES
PSH100A Series
Single 100 VA, 120 Vac to 24 Vac, UL Class 2, Metal Enclosure

POWER SUPPLIES

120 Vac Convenience Outlet *

24 Vac Breaker

24 Vac

ON OFF

On/O Switch

RESET

LED

Indicator

OFF

5.438" 5.150"

ON 4.500"

RESET

OFF

4.250"

OFF

4.500"

Com

24 Vac

120 Vac Convenience Outlet *

10 Amp Main Breaker/Switch

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

5.150"

SPECIFICATIONS
Transformer: One 100 VA Split-Bobbin Over Current Protection: Circuit Breaker
Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts

PSH100A SERIES SELECTION GUIDE

Model #
PSH100A PSH100AW PSH100AB10* PSH100AWB10*

120 Vac Outlets
· · · ·

Aux Output Wire
· ·

Main Breaker on Input Power
10 Amp Switch / Breaker 10 Amp Switch / Breaker

Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires

Class 2

Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac

All Other Models Primary Wires BLK: 120 Vac WHT: Common

Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^
https://hcai.ca.gov/wp-content/
uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling

"W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common

AC POWER SUPPLIES

PSH75A75A Series
Dual 75 VA, Multi-tap
480/277/240/208/120 to 24 Vac, UL
Class 2, Metal Enclosure
24 Vac On/O Switch
24 Vac Breaker 120 Vac Convenience Outlet *

8.625" 8.250"

24 Vac Breaker

ON OFF

24 Vac

ON OFF

On/O Switch

ON OFF

RESET

ON OFF

RESET

LED Indicator

OFF OFF

4.500" 4.250"

4.500"

Com 24 Vac

Com

24 Vac

120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

8.250"

SPECIFICATIONS
Transformer: Two 75 VA Split-Bobbin Over Current Protection: Circuit Breaker
Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 H x 8.625 W x 4.500 D Origin: Made of US and non-US parts

PSH75A75A SERIES SELECTION GUIDE

Model #

120 Vac Aux Output Outlets Wire

Main Breaker on Input Power

PSH75A75A

·

PSH75A75AW

·

PSH75A75AB10*

·

·

10 Amp Switch / Breaker

PSH75A75AWB10* ·

·

10 Amp Switch / Breaker

Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires

Class 2

Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac

All Other Models Primary Wires** GRY: 480 Vac BRN: 277 Vac ORG: 240 Vac RED: 208 Vac WHT: 120 Vac BLK: Common
"W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common

Notes: · All dual models: Model number denotes location of transformer within enclosure. PSH75A75A
Left side Right side · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^
https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling · All primary voltages other than 120 Vac will result in the disabling of convenience outlets.**

112

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER SUPPLIES

AC POWER SUPPLYIES
PSH100A100A Series
Dual 100 VA, 120 Vac to 24 Vac, UL Class 2, Metal Enclosure

24 Vac On/O Switch
24 Vac Breaker 120 Vac Convenience Outlet *

24 Vac Breaker

24 Vac

ON OFF

ON OFF

On/O Switch

RESET

LED Indicator

OFF

Com 24 Vac

Com

24 Vac

120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.
SPECIFICATIONS

8.625" 8.250"

ON

ON

OFF

OFF

RESET

OFF

8.250"

4.500" 4.250"

4.500"

PSH100A100A SERIES SELECTION GUIDE

Model #
PSH100A100A PSH100A100AW PSH100A100AB10* PSH100A100AWB10*

120 Vac Outlets
· · · ·

Aux Output Wire

Main Breaker on Input Power

·

10 Amp Switch / Breaker

·

10 Amp Switch / Breaker

Secondary Configuration External Terminal Strip Internal Wires External Terminal Strip Internal Wires

Class 2

Transformer: Two 100 VA Split-Bobbin

Input Wires: "B10 Models Only

Over Current Protection: Circuit Breaker

Input Power Wires

Frequency: 50/60 Hz

BLK: 120 Vac

24 Vac ON/OFF: On / Off Switch & Breaker

WHT: Neutral

Main Breaker ON/OFF: Switch / Breaker (10 Amp)

GRN: Ground

(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508,

Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground

C-UL, CE, RoHS,

Output Wires: "B10 Models Only

Special ^ Seismic Certification of Equipment and

Auxiliary Output

Components: OSP-0201-10

BLU: 120 Vac

Dimensions: 4.500 H x 8.625 W x 4.500 D

Origin: Made of US and non-US parts

All Other Models Primary Wires BLK: 120 Vac WHT: Common
"W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common

Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^
https://hcai.ca.gov/wp-content/
uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling

AC POWER SUPPLYIES

PSH500A
500 VA Power Supply, Five 100 VA Class 2 Outputs,
480/277/240/120 Vac to 24 Vac, Metal Enclosure

PSMN500A
500 VA Power Supply, Five 100 VA Class 2 Outputs,
480/277/240/120 Vac to 24 Vac, Polymetal Sub-
panel Pre-Mounted

480 277 240 120 COMM
ON 1
OFF
ON OFF 2
ON OFF 3
ON OFF 4
ON OFF 5

24V COM 24V COM 24V COM 24V COM 24V COM

User Connections

PSMN500A

SPECIFICATIONS

Switch Indicator
Breaker

Transformer: One (1) 500 VA

Over Current Protection: Circuit Breaker

Primary: 480/277/240/120 Vac

Frequency: 50/60 Hz

Dimensions: 12.125 H x 12.125 W x 6.000 D (PSH500A)

11.330 H x 11.400 W x 5.000 D (PSMN500A)

Origin: Made of US and non-US parts

Approvals: Class 2 (UL Approved UL5085-3),

UL916, C-UL, CE, RoHS, Special

^ Seismic Certification of Equipment and

Components: OSP-0201-10

Housing: NEMA1 Metal Enclosure (PSH500A)

Notes:

Sub-Panel: Plenum Rated Polymetal (PSMN500A)

· To order UL508, add "-IC" to end of model number.

· Primary voltage terminal cover available.

· Design is in accordance with ASCE 7-05 Chapter 13: ^

https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf

· Consult factory for OSP labeling

5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 5 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire.
Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously)
· With 240 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature

PSH500A Shown WithCover
Class 2
PSH500A Shown Without Cover
Standby Wattage: 48.515 W @ 120 Vac 48.699 W @ 240 Vac 49.564 W @ 277 Vac 48.255 W @ 480 Vac Full Load Primary Current: 4.66 A @ 120 Vac 2.41 A @ 240 Vac 2.06 A @ 277 Vac 1.17 A @ 480 Vac Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp

(800) 888-5538 | www.functionaldevices.com

113

AC POWER SUPPLYIES

PSH300A
300 VA Power Supply, Three 100 VA Class 2 Outputs,
480/277/240/120 Vac to 24 Vac, Metal Enclosure

480 277 240 120 COMM
ON 1
OFF
ON OFF 2
ON OFF 3

24V COM 24V COM 24V COM

PSMN300A
300 VA Power Supply, Three 100 VA Class 2 Outputs,
480/277/240/120 Vac to 24 Vac, Polymetal Subpanel
Pre-Mounted

PSH300A Shown Without Cover

POWER SUPPLIES
User Connections

PSMN300A

SPECIFICATIONS

Switch Indicator
Breaker

Transformer: One (1) 300 VA

Over Current Protection: Circuit Breaker

Primary: 480/277/240/120 Vac

Frequency: 50/60 Hz

Dimensions: 12.125 H x 12.125 W x 6.000 D (PSH300A)

11.330 H x 11.400 W x 5.000 D (PSMN300A)

Origin: Made of US and non-US parts

Approvals: Class 2 (UL Approved UL5085-3),

UL916, C-UL, CE, RoHS, Special

^ Seismic Certification of Equipment and

Components: OSP-0201-10

Housing: NEMA1 Metal Enclosure (PSH300A)

Notes:

Sub-Panel: Plenum Rated Polymetal (PSMN300A)

· To order UL508, add "-IC" to end of model number.

· Primary voltage terminal cover available.

· Design is in accordance with ASCE 7-05 Chapter 13: ^

https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf

· Consult factory for OSP labeling

3 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 3 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire.
Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 3 Outputs Operated Simultaneously)
· With 120 Vac primary input voltage · When all 3 outputs operated simultaneously, at room temperature

AC POWER SUPPLYIES

PSH200A
200 VA Power Supply, Five 40 VA Class 2 Outputs,
480/347/277/240/120 Vac to 24 Vac, Metal Enclosure

347 480 277 240 120 COMM
ON 1
OFF
ON OFF 2
ON OFF 3
ON OFF 4
ON OFF 5

24V COM 24V COM 24V COM 24V COM 24V COM

SPECIFICATIONS

Switch Indicator
Breaker

User Connections

PSMN200A
200 VA Power Supply, Five 40 VA Class 2 Outputs, 480/347/277/240/120 Vac to 24 Vac, Polymetal Subpanel Pre-Mounted
PSMN300A 347 VAC INPUT VOLTAGE PROVIDES DIRECT CONVERSION FROM MANY CANADIAN SYSTEMS TO CLASS 2 OUTPUTS PERFECT FOR ISOLATING UP TO FIVE ZONE CONTROLLERS

Transformer: One (1) 200 VA Over Current Protection: Circuit Breaker
Primary: 480/347/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 H x 12.125 W x 6.000 D (PSH200A)
11.330 H x 11.400 W x 5.000 D (PSMN200A) Origin: Made of US and non-US parts Approvals: Class 2 (UL Approved UL5085-3),
UL916, C-UL, CE, RoHS Housing: NEMA1 Metal Enclosure (PSH200A) Sub-Panel: Plenum Rated Polymetal (PSMN200A)
Notes: · Primary voltage terminal cover available.

5 Secondaries: 24 Vac, with LED Indicators
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 480/347/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 5 Ungrounded, Isolated, 40 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire.
Ambient Temperature Derating: 1.6A up to 40° C ; 1.2A up to 60° C (When All 5 Outputs Operated Simultaneously)
· With 120 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature

PSH300A Shown Without Cover

Class 2

Standby Wattage: 16.61 W @ 120 Vac 17.70 W @ 240 Vac 16.26 W @ 277 Vac 19.20 W @ 480 Vac
Full Load Primary Current: 2.66 A @ 120 Vac 1.36 A @ 240 Vac 1.18 A @ 277 Vac 0.68 A @ 480 Vac
Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp

PSH200A Shown Without Cover
Class 2
PSH200A Shown Without Cover
Standby Wattage: 18.93 W @ 120 Vac 22.08 W @ 240 Vac 22.33 W @ 277 Vac 23.11 W @ 347 Vac 25.24 W @ 480 Vac Full Load Primary Current: 2.57 A @ 120 Vac 1.44 A @ 240 Vac 1.17 A @ 277 Vac 0.95 A @ 347 Vac 0.73 A @ 480 Vac Secondary Output Voltage vs. Load: 24.9 V @ 0.5 Amp 24.0 V @ 1.0 Amp 23.9 V @ 1.4 Amp 23.7 V @ 1.6 Amp

114

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER SUPPLIES

AC POWER SUPPLY

PSH500A-LVC
500 VA Power Supply, Five 100 VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac,
Hi/Lo Voltage Separate Wiring Compartments, Metal Enclosure

SPECIFICATIONS

480 277 240 120 COMM
ON 1
OFF
ON OFF 2
ON OFF 3
ON OFF 4
ON OFF 5

24V COM 24V COM 24V COM 24V COM 24V COM

Switch Indicator
Breaker

User Connections

PSH500A-LVC Shown With Full Cover & Access Plate

PSH500A-LVC Shown Without High Voltage Cover & Low Voltage
Access Plate
PSH500A-LVC Shown Without
Low Voltage Access Plate

Class 2

Transformer: One (1) 500 VA

Over Current Protection: Circuit Breaker

Primary: 480/277/240/120 Vac

Frequency: 50/60 Hz

Dimensions: 12.125 H x 12.125 W x 6.000 D

Origin: Made of US and non-US parts

Approvals: Class 2 (UL Approved UL5085-3),

UL916, C-UL, CE, RoHS

^ Seismic Certification of Equipment and

Components: OSP-0201-10

Housing: NEMA1 Metal Enclosure with

Notes:

high/low separation

· Design is in accordance with ASCE 7-05 Chapter 13: ^

https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf

· Consult factory for OSP labeling

5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 5 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire.
Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously)
· With 240 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature

Standby Wattage: 48.515 W @ 120 Vac 48.699 W @ 240 Vac 49.564 W @ 277 Vac 48.255 W @ 480 Vac
Full Load Primary Current: 4.66 A @ 120 Vac 2.41 A @ 240 Vac 2.06 A @ 277 Vac 1.17 A @ 480 Vac
Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp

AC POWER SUPPLY

PSH300A-LVC
300 VA Power Supply, Three 100 VA Class 2 Outputs, 480/277/240/120 Vac to 24
Vac, Hi/Lo Voltage Separate Wiring Compartments, Metal Enclosure

480 277 240 120 COMM
ON 1
OFF
ON OFF 2
ON OFF 3

24V COM 24V COM 24V COM

Switch Indicator
Breaker

User Connections

PSH300A-LVC Shown With Full Cover & Access Plate

PSH300A-LVC Shown Without High Voltage
Cover & Low Voltage Access Plate
PSH300A-LVC Shown Without
Low Voltage Access Plate

SPECIFICATIONS
Transformer: One (1) 300 VA Over Current Protection: Circuit Breaker
Primary: 480/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 H x 12.125 W x 6.000 D
Origin Made of US and non-US parts Approvals: Class 2 (UL Approved UL5085-3),
UL916, C-UL, CE, RoHS ^ Seismic Certification of Equipment and Components: OSP-0201-10 Housing: NEMA1 Metal Enclosure
Notes: · Design is in accordance with ASCE 7-05 Chapter 13: ^
https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling

3 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 3 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire.
Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 3 Outputs Operated Simultaneously)

Standby Wattage: 16.61 W @ 120 Vac 17.70 W @ 240 Vac 16.26 W @ 277 Vac 19.20 W @ 480 Vac
Full Load Primary Current: 2.66 A @ 120 Vac 1.36 A @ 240 Vac 1.18 A @ 277 Vac 0.68 A @ 480 Vac

Class 2
Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp · With 120 Vac primary input voltage · When all 3 outputs operated simultaneously, at room temperature

(800) 888-5538 | www.functionaldevices.com

115

POWER SUPPLIES
User Connections

AC POWER SUPPLY

PSH200A-LVC
200 VA Power Supply, Five 40 VA Class 2 Outputs, 480/347/277/240/120 Vac to 24 Vac,
Hi/Lo Voltage Separate Wiring Compartments, Metal Enclosure

347 480 277 240 120 COMM
ON 1
OFF
ON OFF 2
ON OFF 3
ON OFF 4
ON OFF 5

24V COM 24V COM 24V COM 24V COM 24V COM

PSH200A-LVC Shown With Full Cover & Access Plate

PSH200A-LVC Shown Without High Voltage
Cover & Low Voltage Access Plate
PSH200A-LVC Shown Without
Low Voltage Access Plate

SPECIFICATIONS

Switch
Indicator Breaker

Transformer: One (1) 200 VA Over Current Protection: Circuit Breaker
Primary: 480/347/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 H x 12.125 W x 6.000 D
Origin: Made of US and non-US parts Approvals: Class 2 (UL Approved UL5085-3),
UL916, C-UL, CE, RoHS Housing: NEMA1 Metal Enclosure

5 Secondaries: 24 Vac, with LED Indicators
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 480/347/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 5 Ungrounded, Isolated, 40 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire.
Ambient Temperature Derating: 1.6A up to 40° C ; 1.2A up to 60° C (When All 5 Outputs Operated Simultaneously)

Standby Wattage: 18.93 W @ 120 Vac 22.08 W @ 240 Vac 22.33 W @ 277 Vac 23.11 W @ 347 Vac 25.24 W @ 480 Vac
Full Load Primary Current: 2.57 A @ 120 Vac 1.44 A @ 240 Vac 1.17 A @ 277 Vac 0.95 A @ 347 Vac 0.73 A @ 480 Vac

Class 2
Secondary Output Voltage vs. Load: 24.9 V @ 0.5 Amp 24.0 V @ 1.0 Amp 23.9 V @ 1.4 Amp 23.7 V @ 1.6 Amp · With 120 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature

116

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER SUPPLIES

AC POWER SUPPLY
PSH500AB10-LVC
500 VA Power Supply, Five 100 VA Class 2 Outputs, 120 Vac to 24 Vac, Hi/Lo Voltage Separate Wiring Compartments, Exterior 120 Vac Receptacle and Circuit Breakers Switches, Metal Enclosure

Hot Neut GND

10 Amp Breaker/Switch 4 Amp Breaker

120 Vac Receptacle
Chassis Ground Switch 4 Amp Breaker

LED Indicator

Switch 4 Amp Breaker

LED Indicator

120 Vac Neutral

Switch 4 Amp Breaker LED Indicator
Switch 4 Amp Breaker LED Indicator
Switch 4 Amp Breaker

PSH500AB10-LVC Shown With High Voltage
Cover & Low Voltage Access Plate

SPECIFICATIONS

LED Indicator

Transformer: One (1) 500 VA Over Current Protection: Circuit Breaker
Primary: 120 Vac Frequency: 50/60 Hz Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: 1 Outlet & Transformer) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 12.125 H x 12.125 W x 6.000 D Origin: Made of US and non-US parts Housing: NEMA1 Metal Enclosure with high/low separation

5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 5 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire.
Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously)

Notes:

· 4A (Breaker protected) Convenience Receptacle Provided

· Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling

Standby Wattage: 48.515 W @ 120 Vac
Full Load Primary Current: 4.66 A @ 120 Vac
Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp
· When all 5 outputs operated simultaneously, at room temperature

Class 2

(800) 888-5538 | www.functionaldevices.com

117

POWER SUPPLIES

AC POWER SUPPLY
PSH300AB10-LVC
300 VA Power Supply, Three 100 VA Class 2 Outputs, 120 Vac to 24 Vac, Hi/Lo Voltage Separate Wiring Compartments, Exterior 120 Vac Receptacle and Circuit Breakers Switches, Metal Enclosure

Hot Neut GND

10 Amp Breaker/Switch

4 Amp Breaker

120 Vac Neutral

120 Vac Receptacle

Chassis Ground Switch 4 Amp Breaker
Switch 4 Amp Breaker
Switch 4 Amp Breaker

LED Indicator
LED Indicator
LED Indicator

PSH300AB10-LVC Shown With High Voltage
Cover & Low Voltage Access Plate

Class 2

SPECIFICATIONS

Transformer: One (1) 300 VA Over Current Protection: Circuit Breaker
Primary: 120 Vac Frequency: 50/60 Hz Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: 1 Outlet & Transformer) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 12.125 H x 12.125 W x 6.000 D Origin: Made of US and non-US parts Housing: NEMA1 Metal Enclosure with high/low separation Notes:

3 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 3 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire.
Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously)

· 4A (Breaker protected) Convenience Receptacle Provided

· Design is in accordance with ASCE 7-05 Chapter 13: ^ https://hcai.ca.gov/wp-content/uploads/2020/10/OSP-0201.pdf · Consult factory for OSP labeling

Standby Wattage: 16.61 W @ 120 Vac
Full Load Primary Current: 2.66 A @ 120 Vac
Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp
· When all 5 outputs operated simultaneously, at room temperature

118

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER SUPPLIES

AC POWER SUPPLY
PSH200AB10-LVC
200 VA Power Supply, Five 40 VA Class 2 Outputs, 120 Vac to 24 Vac, Hi/Lo Voltage Separate Wiring Compartments, Exterior 120 Vac Receptacle and Circuit Breakers Switches, Metal Enclosure

Hot Neut GND

10 Amp Breaker/Switch

4 Amp Breaker

120 Vac Neutral

120 Vac Receptacle

Chassis Ground Switch 2 Amp Breaker Switch 2 Amp Breaker Switch 2 Amp Breaker Switch 2 Amp Breaker Switch 2 Amp Breaker

LED Indicator
LED Indicator
LED Indicator
LED Indicator
LED Indicator

PSH200AB10-LVC Shown With High Voltage
Cover & Low Voltage Access Plate

Class 2

SPECIFICATIONS

Transformer: One (1) 200 VA

Over Current Protection: Circuit Breaker

Primary: 120 Vac

Frequency: 50/60 Hz

Main Breaker ON/OFF: Switch / Breaker (10 Amp)

(Kills power to entire unit:

1 Outlet & Transformer)

Approvals: Class 2 (UL Approved UL5085-3),

UL916, C-UL, CE, RoHS

Dimensions: 12.125 H x 12.125 W x 6.000 D

Origin: Made of US and non-US parts

Housing: NEMA1 Metal Enclosure with

Notes:

high/low separation

· 4A (Breaker protected) Convenience Receptacle Provided

5 Secondaries: 24 Vac, with LED Indicators 2 Amp breaker for each output
24 Vac ON/OFF: On / Off Switch & Breaker
Input: 120 Vac Finger-Safe Terminals, 8-18 AWG
Output: 5 Ungrounded, Isolated, 40 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire.
Ambient Temperature Derating: 1.6A up to 40° C ; 1.2A up to 60° C (When All 5 Outputs Operated Simultaneously)

Standby Wattage: 18.93 W @ 120 Vac
Full Load Primary Current: 2.57 A @ 120 Vac
Secondary Output Voltage vs. Load: 24.9 V @ 0.5 Amp 24.0 V @ 1.0 Amp 23.9 V @ 1.4 Amp 23.7 V @ 1.6 Amp
· When all 5 outputs operated simultaneously, at room temperature

(800) 888-5538 | www.functionaldevices.com

119

AC POWER SUPPLY
CTRL-PS
40 VA Power Supply, 120 to 24 Vac, DIN rail and 14.5"x 7.7"x 3.9" Enclosure
120 Vac Line Input
7.70" 5.70"

POWER SUPPLIES
14.50" 11.50" 14.50"

ON OFF

SPECIFICATIONS

24 Vac Device Output

Transformer: One 40 VA Primary: 120 Vac
Secondary: 24 Vac, isolated Frequency: 50/60 Hz Overload Protection: Inherently Limited
Status: LED On = Activated ON/OFF Switch: 2 Position Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS (PSMN40AS) UL916, C-UL, CE, RoHS (MH1000 Series)
Dimensions: 14.50 D x 7.70 W x 3.90 D Origin: Made of US and non-US parts
Housing: NEMA 1 Metal Enclosure with screw cover

3.90"

7.70"

Shown With Cover

Notes: · Track mounted power supply may be ordered separately as model PSMN40AS. · 40 VA power supply mounted in MT212-4 track, high/low voltage barrier and 8.75 of 35 mm top hat DIN rail for mounting of desired controller in one metal enclosure. · Controller must be 9.50 x 6.75 x 3.50 or smaller with DIN rail mounting capability,
or 9.50 x 6.75 x 3.125 without DIN rail mounting capability. · Controller not included.

GREAT FOR ZONE & NETWORK CONTROLLERS

AC POWER SUPPLYIES

MHP3903100AB10

Single 100 VA Power Supply, Polymetal Subpanel Mounted,

12.5" x 24.5" x 6.5" Metal Enclosure

10.60"

12.50"

MHP3904100AB10
Single 100 VA Power Supply, Perforated Steel Subpanel
Mounted, 12.5" x 24.5" x 6.5" Metal Enclosure

1111.7.75050" "

5.15" 5.438" 5.150"

4.50" 4.500"

4.50" 4.25"

99..000000""

1100.7.57005" "

.050.050"0"

ON 4.500"

RESET

OFF

4.250"

OFF

5.15" 5.150"

1 199..000000""

22.00" 24.50"

9.90.0000"0"

88.5.05000" "

6.50"

12.50"

POWER SUPPLY (PS100AB10)

0.5.50000" "

1.21.244"" 1.10.077""

SELECTION GUIDE
Model # MHP3903100AB10 MHP3904100AB10

Sub-Panel Polymetal Perforated Steel

Class 2

Transformer: One 100 VA Split-Bobbin

Input Wires: Input Power Wires

Over Current Protection: Circuit Breaker

BLK: 120 Vac

Frequency: 50/60 Hz

WHT: Neutral

24 Vac ON/OFF: On / Off Switch & Breaker

GRN: Ground

Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer) Total Combined Output 9A
Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS
Dimensions: 4.500 H x 8.625 W x 4.500 D

Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: Auxiliary Output BLU: 120 Vac

Origin: Made of US and non-US parts POLYMETAL SUB-PANEL (SP3803S)

Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13
METAL HOUSING
Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 12.50" (W) x 24.50" (H) x 6.50" (D)
PERFORATED STEEL SUB-PANEL (SP3804S)

Mounting Area: 220.60 square Approvals: Plenum Rated
Dimensions: 19.00" x 11.75"

Mounting Area: 220.60 square Approvals: Plenum Rated
Dimensions: 19.00" x 11.75"

120

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER SUPPLIES

AC POWER SUPPLYIES

MHP3903100A100AB10
Dual 100 VA Power Supplies, Polymetal Subpanel
Mounted, 12.5" x 24.5" x 6.5" Metal Enclosure

10.60"

12.50"

MHP3904100A100AB10
Dual 100 VA Power Supplies, Perforated Steel Subpanel
Mounted, 12.5" x 24.5" x 6.5" Metal Enclosure

1111.7.75050" "

8.625"
88..22505" "

44..55000" "

44..5050"0" 44..2520"5"

99..000000""

1100.7.57005" "

.050.050"0"

ON

ON

OFF

OFF

RESET

OFF

88.2.2550""

1 199..000000""

22.00" 24.50"

9.90.0000"0"

88.5.05000" "

6.50"

12.50"

(PS100A100AB10)

0.5.50000" "

11.2.42" 4"
1.07"
1.07"

SELECTION GUIDE
Model # MHP3903100A100AB10 MHP3904100A100AB10

Sub-Panel Polymetal Perforated Steel

Class 2

Transformer: Two 100 VA Split-Bobbin

Input Wires: Input Power Wires

Over Current Protection: Circuit Breaker

BLK: 120 Vac

Frequency: 50/60 Hz

WHT: Neutral

24 Vac ON/OFF: On / Off Switch & Breaker

GRN: Ground

Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer) Total Combined Output 9A
Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS
Dimensions: 4.500 H x 8.625 W x 4.500 D

Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: Auxiliary Output BLU: 120 Vac

Origin: Made of US and non-US parts POLYMETAL SUB-PANEL (SP3803S)

Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13
METAL HOUSING
Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 12.50" (W) x 24.50" (H) x 6.50" (D)
PERFORATED STEEL SUB-PANEL (SP3804S)

Mounting Area: 220.60 square Approvals: Plenum Rated
Dimensions: 19.00" x 11.75"

Mounting Area: 220.60 square Approvals: Plenum Rated
Dimensions: 19.00" x 11.75"

AC POWER SUPPLY

MHP4604100AB10
Single 100 VA Power Supply, Perforated Steel Subpanel Mounted, 16.15" x 20.0" x 6.72" Metal Enclosure
14.25"

14.87" 13.00"

.88"

5.15" 5.438" 5.150"

4.50" 4.500"

ON 4.500"

RESET

OFF

4.250"

OFF

5.15" 5.150"

17.50" 20.00"
14.62" 12.87"
4.50" 4.25"

16.15"
6.72"
12.00" 1.44"
POWER SUPPLY (PS100AB10)
Transformer: One 100 VA Split-Bobbin Over Current Protection: Circuit Breaker
Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer) Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 H x 5.150 W x 4.500 D Origin: Made of US and non-US parts

1.24"
.89"
Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: Auxiliary Output BLU: 120 Vac

Class 2
Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13
METAL HOUSING (MH4600)
Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 16.15" (W) x 20.00" (H) x 6.72" (D)
PERFORATED STEEL SUB-PANEL (SP4604)
Mounting Area: 214.85 square Approvals: Plenum Rated
Dimensions: 14.62" x 14.87"

(800) 888-5538 | www.functionaldevices.com

121

17.50"

AC POWER SUPPLY

MHP4604100A100AB10

Dual 100 VA Power Supplies, Perforated Steel Subpanel Mounted, 16.15" x 20.0" x 6.72" Metal Enclosure

14.87"

14.25"

13.00"

.88"
ON OFF

8.625"
88..22505" "
ON OFF RESET
OFF

88.2.2550""

44..5050"0" 44..2520"5"

44..55000" "

20.00"
14.62" 12.87"

POWER SUPPLIES

16.15"
6.72"
12.00" 1.44"
POWER SUPPLY (PS100A100AB10)
Transformer: Two 100 VA Split-Bobbin Over Current Protection: Circuit Breaker
Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer) Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 H x 8.625 W x 4.500 D Origin: Made of US and non-US parts

1.24"
.89"
Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: Auxiliary Output BLU: 120 Vac

ADC POWER SUPPLY: 24 VAC TO 1.5 - 28 VDC
PSP24DA
DC Power Supply, Non-Isolated Linear, 24 Vac to 1.5-28 Vdc, Adjustable Output, NEMA 1 Housing
VOLTAGE INPUT 24 Vac

Class 2
Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13
METAL HOUSING (MH4600)
Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 16.15" (W) x 20.00" (H) x 6.72" (D)
PERFORATED STEEL SUB-PANEL (SP4604)
Mounting Area: 214.85 square Approvals: Plenum Rated
Dimensions: 14.62" x 14.87"

Wht/Yel Wht/Yel

VOLTAGE OUTPUT Factory Set to 24 Vdc Adjustable from 1.5-28 Vdc

+ Wht/Red ­ Wht/Blu

Class 2

SPECIFICATIONS
Voltage Input: 24 Vac, full-wave rectified Voltage Output: 1.5 - 28 Vdc non-isolated
Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50"NPT nipple
Housing Detail: See Housing B in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated
ON/OFF Switch: None Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS
Housing Rating: UL Accepted for Use in Plenum, NEMA 1

Output Current Ratings: 116 mA @ 10 Vdc 125 mA @ 12 Vdc 300 mA @ 24 Vdc
Input Current Rating: 550 mA Maximum

Percent Ripple:

Notes:

0.0016%, 24 Vdc @ 300 mA

· Requires a separate ungrounded

transformer when used in

Regulation: Load: 0.04% No Load to Full Load Line: 0.0125 V/V

conjunction with 1/2 wave rectified power supplies, grounded 24 Vac transformers, or when 24 Vac and 24 Vdc are

connected in common.

122

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

ADC POWER SUPPLY: 120 VAC TO 24 VDC
PSH24DWB10
DC Power Supply, Single Switching, 120-24 Vdc at 2.5 Amp, Metal Enclosure

4.500" 4.250"
POWER SUPPLIES

120 Vac Convenience Outlet *

5.438" 5.150"

4.500"

4.500"

RESET

RESET

4.250"

OFF

OFF

120 Vac Convenience Outlet *
10 Amp Main Breaker/Switch
* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

5.150"

SPECIFICATIONS
Input Voltage: 120 Vac Frequency: 50/60 Hz DC Output: 24 Vdc @ 2.5 Amp
Over Current Protection: Circuit Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit)* Total Combined Output 9A
Operating Temperature: 32 to 122°F Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts

Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Notes: · This device is not certified for use as a Class 2 power source.

ADC POWER SUPPLY: 120 VAC TO 24 VAC AND 24 VDC
PSH100A24DWB10
DC Power Supply, 100 VA, 120 to 24 Vac and Switching 120 to 24 Vdc at 2.5 Amp, Metal Enclosure

Output Wires: DC Supply Output WHT/RED: 24 Vdc WHT/BLU: 24 Vdc COM
Auxiliary Output BLU: 120 Vac

24 Vac On/O Switch
24 Vac Breaker 120 Vac Convenience Outlet *

8.625" 8.250"

ON OFF
RESET
OFF

ON OFF
RESET
OFF

LED Indicator

120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

8.250"

SPECIFICATIONS
Transformer: One 100 VA Split-Bobbin Voltage Input: 120 Vac
Frequency: 50/60 Hz Over Current Protection: Circuit Breaker
24 Vac ON/OFF: Switch / Breaker (4 Amp) Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer, and 24 Vdc)* Total Combined Output 9A Dimensions: 4.500 H x 8.625 W x 4.500 D Origin: Made of US and non-US parts

4.500"
Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Notes: · This device is not certified for use as a Class 2 power source.

Output Wires: DC Supply Output WHT/RED: 24 Vdc WHT/BLU: 24 Vdc COM
Auxiliary Output BLU: 120 Vac
Transformer Output WHT/YEL: 24 Vac WHT/BLU: 24 Vac COM

(800) 888-5538 | www.functionaldevices.com

123

POWER SUPPLIES

ADC POWER SUPPLYIES: 24 VAC TO 1.5 - 28 VDC

PSMN24DA
DC Power Supply, Non-Isolated Linear, 24 Vac to
1.5-28 Vdc, 300mA Adjustable Output, 2.75" Track
Mount

PSMN24DAS
DC Power Supply, Non-Isolated Linear, 24 Vac to
1.5-28 Vdc, 300mA Adjustable Output, Switch,
2.75" Track Mount

Toggle Switch : On / O

Voltage Input 24 Vac

Voltage Output Adjustable 1.5-28Vdc
­
+

Voltage Input 24 Vac

Voltage Output Adjustable 1.5-28Vdc
­
+

Class 2

SPECIFICATIONS

Voltage Input: 24 Vac, full-wave rectified

Output Current Ratings:

Voltage Output: 1.5 - 28 Vdc non-isolated

116 mA @ 10 Vdc

Frequency: 50/60 Hz

125 mA @ 12 Vdc

Overload Protection: Electrical and Thermal, Auto-Reset

300 mA @ 24 Vdc

Operating Temperature: -30 to 140° F

Humidity Range: 5 to 95% (noncondensing)

Input Current Rating:

Power Status: LED On = Activated

550 mA Maximum

Dimensions: 1.75"H x 2.75"W x 1.25"D1/1.75"D2

Housing Detail: See Housing H in housing guide for dimensions

Origin: Made of US and non-US parts

Track Mount: 2.750

MT212-2 Mounting Track Supplied

ON/OFF Switch: None (PSMN24DA)

2 Position Toggle (PSMN24DAS)

Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL,

CE, RoHS

Percent Ripple: 0.0016%, 24 Vdc @ 300 mA
Regulation: Load: 0.04% No Load to Full Load Line: 0.0125 V/V

Notes: · Requires a separate ungrounded transformer when used in conjunction with 1/2 wave rectified power supplies, grounded 24 Vac transformers, or when 24 Vac and 24 Vdc are connected in common.

ADC POWER SUPPLY: 24 VAC TO 1.5 - 14 VDC
PSM20A12DAS
DC Power Supply, Isolated Linear, 24 Vac to 1.5Vdc-14Vdc, 300mA Adjustable Output, Track Mount

Voltage Output Adjustable From
1.5-14 Vdc ­+

Voltage Input 24 Vac
Switch: On / O

SPECIFICATIONS
Voltage Input: 24 Vac Voltage Output: 1.5 - 14 Vdc Isolated
Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 2.75"H x 4.00"W x 1.75"D1/2.25"D2
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 4.000 and 2.750 MT212-4 Mounting Track Supplied
ON/OFF Switch: 2 Position Approvals: Class 2, UL916, C-UL, CE, RoHS,

Output Current Ratings: 300 mA @ 12 Vdc
Input Current Rating: 950 mA Maximum

Class 2
Percent Ripple: 0.0016%, 12 Vdc @ 300 mA Regulation: Load: 0.04% No Load to Full Load Line: 0.0080 mV/V

124

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER SUPPLIES

ADC POWER SUPPLYIES: 24 VAC TO 1.5 - 28 VDC

PSM24A24DAS
DC Power Supply, Isolated Linear, 24 Vac to 1.5-28
Vdc, 300mA Adjustable Output, Track Mount

PSM19A24DAS
DC Power Supply, Isolated Linear, 120 Vac to 1.5-
28 Vdc, 300mA Adjustable Output, Track Mount

Voltage Output Adjustable From 1.5-28 Vdc
­+

Voltage Input 24 Vac
Switch: On / O

Voltage Output Adjustable From 1.5-28 Vdc
­+

Voltage Input 120 Vac
Switch: On / O

SPECIFICATIONS
Voltage Input: 24 Vac (PSM24A24DAS) 120 Vac (PSM19A24DAS)
Voltage Output: 1.5 - 28 Vdc Isolated Frequency: 50/60 Hz
Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 2.75"H x 4.00"W x 1.75"D1/2.25"D2
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 4.000 and 2.750 MT212-4 Mounting Track Supplied
ON/OFF Switch: 2 Position Max. Ambient Temperature: 40° C (PSM19A24DAS)
Approvals: Class 2, UL916, C-UL, CE, RoHS,

Output Current Ratings: 116 mA @ 10 Vdc 125 mA @ 12 Vdc 300 mA @ 24 Vdc
Input Current Rating: 950 mA Maximum (PSM24A24DAS) 150 mA Maximum (PSM19A24DAS)

ADC POWER SUPPLY: 120 VAC TO 24 VDC
PSMN40A24DS
DC Power Supply, Isolated Linear, 120 Vac to 24 Vdc, 1 Amp Output, 2.75" Track Mount

+­
Voltage Output 24 Vdc

Voltage Input 120 Vac
Switch: On / O

Class 2
Percent Ripple: 0.0016%, 24 Vdc @ 300 mA Regulation: Load: 0.04% No Load to Full Load Line: 0.0080 mV/V (PSM24A24DAS) Line: 0.6250 mV/V (PSM19A24DAS)

SPECIFICATIONS
Voltage Input: 120 Vac Voltage Output: 24 Vdc Isolated
Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 5.00"H x 2.75"W x 2.00"D1/2.50"D2
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 2.750 MT212-6 Mounting Track Supplied
ON/OFF Switch: 2 Position Max. Ambient Temperature: 40° C
Approvals: Class 2, UL916, C-UL, CE, RoHS,

Output Current Ratings: 1 A @ 24 Vdc
Input Current Rating: 400 mA Maximum

Percent Ripple: 0.0016%, 24 Vdc @ 1 A
Regulation: Load: 0.50% No Load to Full Load Line: 25.0000 mV/V

Class 2

(800) 888-5538 | www.functionaldevices.com

125

POWER SUPPLIES

ADC POWER SUPPLY
PSH100AB10-DC
Enclosed Single Switching DC Power Supplies, 120 to 24 Vdc @ 2.5 Amp, Class 2

120 Vac Convenience Outlet *

24 Vdc Breaker

24 Vdc

ON OFF

On/O Switch

RESET

LED

Indicator

OFF

5.438" 5.150"

4.500"

ON 4.500"

RESET

OFF

4.250"

OFF

Com

24 Vdc

120 Vac Convenience Outlet *

10 Amp Main Breaker/Switch

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.

5.150"

SPECIFICATIONS
Over Current Protection: Circuit Breaker Frequency: 50/60 Hz
24 Vdc ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL508, C-UL, CE, RoHS, FCC Dimensions: 4.500 H x 5.438 W x 4.500 D Origin: Made of US and non-US parts

Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: Auxiliary Output BLU: 120 Vac

AC P&ODWCEPROSWUEPRPSLYUPPLY: 120 VAC TO 24 VAC & 24 VDC
PSH100A100AB10-DC
Enclosed Dual Power Supplies, 100 VA, 120 to 24 Vac and 120 to 24 Vdc @ 2.5 Amp, Class 2

24 Vac On/O Switch

24 Vac Breaker 120 Vac Convenience Outlet *

8.625"

24 Vdc Breaker

8.250"

24 Vdc

ON OFF

ON OFF

On/O Switch

RESET

LED Indicator

ON

ON

OFF

OFF

OFF

RESET

Com 24 Vac

Com

24 Vdc

120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch

OFF
8.250"

* Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker.
SPECIFICATIONS
Over Current Protection: Circuit Breaker Frequency: 50/60 Hz
24 Vac ON/OFF: On / Off Switch & Breaker 24 Vdc ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp)
(Kills power to entire unit: Outlets, Aux. Output, 24 Vac, & 24 Vdc)* Total Combined Output 9A Max. Ambient Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL508, C-UL, CE, RoHS, FCC Dimensions: 4.500 H x 8.625 W x 4.500 D Origin: Made of US and non-US parts

4.500" 4.250"

4.500"
Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground
Output Wires: Auxiliary Output BLU: 120 Vac

Class 2
Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time.
Class 2
Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time.

126

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

TRANSFORMERS

TRANSFORMERS

TR40VA002US

TR100VA009US

TR50VA001US

US MANUFACTURED TRANSFORMERS

· 40 VA through 96 VA · Single and dual hub · Foot or hub mountable · Circuit breaker models

· Class 2 UL Listed · 24 Vac secondary · Single and multi-tap primaries

Transformers may be foot mount, hub mount, or both. Transformers with the hub mount option will have either a single threaded hub or dual threaded hubs. Several transformers are provided with a circuit breaker and many are Class 2. Pigtail wires are standard on most models and are typically 8.00 in length. 1
All transformers utilize split-bobbin construction, making them inherently isolated. Custom transformers are also available (contact factory).

Frequency: 50/60 Hz Hub Style: .5 NPT Hub Wire Length: 8 Typical with .5 Strip 1 Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) MTBF: 100,000 Hours @ 77° F Construction: Split-Bobbin Approvals: CE approved, RoHS. See charts for UL approvals.
1 = TR40VA022 = 8 Primary, 30 Secondary, with .5 Strip TR50VA019 = 28 Typical with .5 Strip TR100VA001-28 = 28 Typical with .5 Strip TR100VA002-20 = 8 Primary, 20 Secondary, with .5 Strip TR150VA001-28 = 28 Typical with .5 Strip
Instructions inside product box include wire colors/voltages.
Additional information on voltage and wire colors is available on individual data sheets on website.

US MANUFACTURED TRANSFORMERS: 40-96 VA

MADE

IN

MODEL #

USA

TR40VA001US ·

·

TR40VA002US ·

·

TR50VA001US ·

·

TR50VA005US ·

·

TR50VA022US ·

·

TR100VA001US ·

·

TR100VA002US ·

·

TR100VA009US ·

·

VA RATING
40VA 40VA 50VA 50VA 50VA 96VA 96VA 96VA

STYLE 1 4 1 2 5 2 5 5

OVER CURRENT CLASS PROTECTION 2
Inherent ·

Inherent ·

Fuse

·

Circuit Brkr. ·

Circuit Brkr. ·

Circuit Brkr. ·

Circuit Brkr. ·

Circuit Brkr. ·

PRIMARY VOLTAGE
(VAC) 120 120 120 120 480/277/240/208/120 120 120 480/277/240/208/120

SEC.

VOLTAGE FOOT (VAC) MOUNT

24

·

24

·

24

·

24

·

24

·

24

·

24

·

24

·

HUBS 1 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 1 Threaded 2 Threaded 2 Threaded

L

W

H

A

B

C

2.380" 2.200" 2.930" 1.720" 1.750" .980"

2.380 2.200 2.920 1.720 1.750 .980"

2.750" 2.200" 2.910" 2.060" 1.750" 1.330"

3.270 2.525 3.250 2.210 2.000 1.130

3.260 2.525 3.290 2.190 2.000 1.120

3.780 2.500 3.290 2.740 2.000 1.630

3.750 2.500 3.290 2.690 2.000 1.600

3.780 2.500 3.270 2.720 2.000 1.630

= Class 2 UL Listed - see data sheet for specific Listing

For full product information, see data sheets on website.

(800) 888-5538 | www.functionaldevices.com

127

TRANSFORMERS

STYLE 1
Single Hub & Foot Mount

STYLE 2
Single Hub & Foot Mount with Circuit Breaker

STYLE 3
Single Hub & Foot Mount with Circuit Breaker

STYLE 4
Dual Hub & Foot Mount

TRANSFORMERS

STYLE 5
Dual Hub & Foot Mount with Circuit Breaker

STYLE 6
Single Hub & Side Opening with Circuit Breaker

STYLE 7
Two Bottom Openings & Foot Mount

STYLE 8
Single Hub, Side Opening & Foot Mount

STYLE 9
Single Hub & Dual Terminal Secondary

STYLE 10
Two End-Bell Openings, & Foot Mount
with Circuit Breaker

STYLE 11
Two Side Openings & Foot Mount

STYLE 12
Dual Hub & Foot Mount with Circuit Breaker

Dimensions: See charts.
C

STYLE 13
90º Conduit Connector & Mounting Plate Opening

A L
1 .50" 8.00"
D

B
1
8.00" .50"

128

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

W H

TRANSFORMERS

TRANSFORMERS

TRANSFORMERS: 20-50 VA

MODEL #

VA RATING STYLE

OVER CURRENT PROTECTION

CLASS 2

TR20VA001

· 20VA

1

Inherent

·

PRIMARY VOLTAGE
(VAC)
120

SEC. VOLTAGE
(VAC)
24

FOOT MOUNT
·

HUBS 1 Threaded

L

W

H

A

B

C

D

2.226" 1.877" 2.595" 1.625" 1.619" 1.013" 2.125"

TR20VA002

· 20VA

4

Inherent

·

208

24

·

2 Threaded 2.296" 1.902" 2.616" 1.604" 1.665" 1.020" 2.114"

TR20VA003

· 20VA

1

Inherent

24

24

·

1 Threaded 2.272" 1.900" 2.628" 1.635" 1.686" 1.023" 2.153"

TR20VA004

· 20VA

4

Inherent

·

277/240/208/120

24

·

2 Threaded 2.310" 1.890" 2.625" 1.540" 1.625" 1.000" 2.100"

TR20VA007

· 20VA

1

Inherent

·

277

24

·

1 Threaded 2.302" 1.895" 2.607" 1.608" 1.685" 1.019" 2.107"

TR40VA001

· 40VA

1

Inherent

·

120

24

·

1 Threaded 2.607" 2.169" 2.906" 2.020" 1.786" 1.204" 2.545"

TR40VA002

· 40VA

4

Inherent

·

120

24

·

2 Threaded 2.634" 2.177" 2.886" 2.007" 1.775" 1.206" 2.564"

TR40VA003

· 40VA

1

Inherent

·

24

24

·

1 Threaded 2.653" 2.171" 2.882" 2.033" 1.779" 1.185" 2.580"

TR40VA004

· 40VA

4

Inherent

·

277/240/208/120

24

·

2 Threaded 2.631" 2.177" 2.882" 1.998" 1.774" 1.189" 2.553"

TR40VA013

· 40VA

2

Circuit Brkr.

480/277/240/208

120

·

1 Threaded 3.267" 2.505" 3.000" 1.699" 1.986" 1.114" 3.325"

TR40VA015

· 40VA

1 Internal Thermal ·

240/208/120

24

·

1 Threaded 2.628" 2.175" 2.907" 2.040" 1.780" 1.188" 2.590"

TR40VA022 # · 40VA

4

Inherent

·

120

24

·

2 Threaded 2.660" 2.172" 2.891" 1.980" 1.786" 1.201" 2.526"

TR40VA040 ^ · 40VA

9 Internal Thermal ·

240/208/120

24

·

1 Threaded 2.728" 2.171" 2.890" 1.995" 1.792" 1.215" 2.550"

TR50VA001

· 50VA

1

Fuse

·

120

24

·

1 Threaded 2.677" 2.178" 2.879" 2.109" 1.793" 1.253" 2.664"

TR50VA002

· 50VA

4

Fuse

·

120

24

·

2 Threaded 2.696" 2.181" 2.908" 2.053" 1.788" 1.278" 2.614"

TR50VA003

· 50VA

4

Fuse

·

240/208

24

·

2 Threaded 2.695" 2.181" 2.899" 2.082" 1.778" 1.294" 2.646"

TR50VA004

· 50VA

5

Circuit Brkr.

·

480/277/240/120

24

·

2 Threaded 3.475" 2.513" 3.014" 1.858" 1.970" 1.291" 2.490"

TR50VA005

· 50VA

2

Circuit Brkr.

·

120

24

·

1 Threaded 3.489" 2.515" 3.008" 1.870" 1.971" 1.294" 2.463"

TR50VA006

· 50VA

1

Fuse

·

277

24

·

1 Threaded 2.763" 2.182" 2.898" 2.135" 1.790" 1.322" 2.698"

TR50VA007

· 50VA

4

Fuse

·

277

24

·

2 Threaded 2.715" 2.173" 2.886" 2.661" 1.784" 1.276" 2.790"

TR50VA008

· 50VA

5

Circuit Brkr.

480/277/240/208

120

·

2 Threaded 3.440" 2.510" 3.012" 1.932" 1.945" 1.346" 2.523"

TR50VA009

· 50VA

5

Circuit Brkr.

·

240/208/120

24

·

2 Threaded 3.412" 2.504" 3.014" 1.864" 2.000" 1.313" 2.485"

TR50VA014

· 50VA

2

Circuit Brkr.

·

277

24

·

1 Threaded 3.479" 2.509" 3.009" 1.873" 1.965" 1.285" 2.480"

TR50VA015

· 50VA

2

Circuit Brkr.

· 480/277/240/208/120 24

·

1 Threaded 3.405" 2.517" 3.013" 1.875" 1.985" 1.316" 2.484"

TR50VA016

· 50VA

2

Circuit Brkr.

·

240/208/120

24

·

1 Threaded 3.345" 2.510" 3.028" 1.842" 1.978" 1.325" 2.454"

TR50VA017

· 50VA

2

Circuit Brkr.

·

480/277/208

24

·

1 Threaded 3.470" 2.520" 3.031" 1.880" 1.872" 1.292" 2.460"

TR50VA018

· 50VA

13

480/277/240/208

120

1, 90° Conduit Connector, 1 Mounting Plate Opening

Refer to data sheet on website.

TR50VA019 #

50VA

11

Inherent

·

277/120

24

·

2 Side Openings 2.470" 2.170" 2.896" 1.850" 1.740" 1.130" 2.512"

TR50VA027

· 50VA

2

Circuit Brkr.

·

240

24

·

1 Threaded

3.450" 2.500" 3.060" 2.030" 1.911" 1.260" 2.450"

FOR 75 - 375 VA TRANSFORMERS, SEE NEXT PAGE.

For full product information, see data sheets on website.

= UL Listed - see data sheet for specific Listing

= UL Component Recognized - see data sheet for specific Listing

# = Refer to website for more wire length information ^ = Dual Terminal Secondary

(800) 888-5538 | www.functionaldevices.com

129

TRANSFORMERS

TRANSFORMERS

TRANSFORMERS: 75-375 VA

MODEL #

OVER

VA

CURRENT CLASS

RATING STYLE PROTECTION 2

TR75VA001

· 75VA

2

Circuit Brkr.

·

PRIMARY VOLTAGE
(VAC) 120

SEC. VOLTAGE FOOT
(VAC) MOUNT

24

·

HUBS 1 Threaded

LWH A B C D 3.743" 2.506" 3.016" 2.256" 1.974" 1.711" 2.873"

TR75VA002

· 75VA

5

Circuit Brkr.

·

120

24

·

2 Threaded

3.890" 2.508" 3.013" 2.290" 1.952" 1.701" 2.882"

TR75VA003

· 75VA

2

Circuit Brkr.

·

277

24

·

1 Threaded

3.875" 2.507" 3.037" 2.269" 1.978" 1.684" 2.860"

TR75VA004

· 75VA

6

Circuit Brkr.

·

480/240/208/120

24

·

1 Threaded 1 Side Opening

3.802" 2.515" 3.050" 2.244" 1.990" 1.665" 2.850"

TR75VA005

· 75VA

2

Circuit Brkr.

·

480/240/208/120

24

·

1 Threaded

3.880" 2.515" 3.030" 2.270" 1.975" 1.700" 2.854"

TR75VA007

· 75VA

5

Circuit Brkr.

·

480/240/208/120

24

·

2 Threaded

3.883" 2.504" 3.034" 2.287" 1.981" 1.708" 2.813"

TR100VA001

· 96VA

2

Circuit Brkr.

·

120

24

·

1 Threaded

4.085" 2.515" 3.030" 2.486" 1.975" 1.900" 3.082"

TR100VA001-28 # · 96VA

2

Circuit Brkr.

·

120

24

·

1 Threaded

4.085" 2.515" 3.030" 2.486" 1.975" 1.900" 3.082"

TR100VA002

· 96VA

5

Circuit Brkr.

·

120

24

·

2 Threaded

4.077" 2.504" 3.023" 2.470" 1.975" 1.888" 3.095"

TR100VA002-20 # · 96VA

5

Circuit Brkr.

·

120

24

·

2 Threaded

3.973" 2.518" 3.033" 2.486" 1.865" 1.924" 3.060"

TR100VA004

· 96VA

5

Circuit Brkr.

·

480/277/240/120

24

·

2 Threaded

4.173" 2.523" 3.041" 2.647" 1.976" 2.086" 3.268"

TR100VA005

· 96VA

2

Circuit Brkr.

·

480/277/240/120

24

·

1 Threaded

4.258" 2.510" 3.030" 2.670" 1.968" 2.065" 3.260"

TR100VA008

· 96VA

5

Circuit Brkr.

480/277/240/208

120

·

2 Threaded

4.220" 2.525" 3.022" 2.690" 1.970" 2.082" 3.272"

TR100VA009

· 96VA

5

Circuit Brkr.

· 480/277/240/208/120 24

·

2 Threaded

4.270" 2.500" 3.060" 2.750" 1.975" 2.000" 2.252"

TR100VA015

· 96VA

2

Circuit Brkr.

· 480/277/240/208/120 24

·

1 Threaded

4.270" 2.500" 3.060" 2.699" 2.030" 2.065" 3.270"

TR100VA026

· 96VA

5

Circuit Brkr.

·

347/120

24

·

2 Threaded

4.040" 2.500" 3.050" 2.500" 2.030" 1.830" 3.070"

TR100VA027

· 96VA

2

Circuit Brkr.

·

240

24

·

1 Threaded

4.050" 2.500" 3.070" 2.510" 2.030" 1.880" 3.063"

TR150VA001

· 150VA

3

Circuit Brkr.

120

24

·

1 Threaded

3.650" 3.800" 3.183" 2.560" 3.150" 1.438" 3.514"

TR150VA001-28 # · 150VA

3

Circuit Brkr.

120

24

·

1 Threaded

3.650" 3.800" 3.183" 2.560" 3.150" 1.438" 3.514"

TR150VA002

· 150VA 12 Circuit Brkr.

120

24

·

2 Threaded

3.620" 3.785" 3.160" 2.568" 3.147" 1.456" 3.511"

TR150VA008

· 150VA 12 Circuit Brkr.

480/277/240/208

120

·

2 Threaded

4.283" 3.786" 3.161" 3.211" 3.148 " 2.116" 4.177"

TR175VA001

· 175VA 7

240/208

24

·

2 Bottom Openings 3.801" 3.790" 3.163" 3.264" 3.141" 2.151" 4.197"

TR175VA002 TR175VA003 TR240VA001

· 175VA 4

· 175VA

1

Thermal Fuse on Primary

· 240VA 8

120

24

·

2 Threaded

3.800" 3.790" 3.189" 3.220" 3.150" 2.100" 4.180"

120

24

·

1 Threaded

4.030" 3.786" 3.161" 3.189" 3.155" 2.127" 4.153"

120

24

·

1 Threaded 1 Bottom Opening

3.957" 3.750" 4.530" 3.350" 3.180" 1.932" 4.025"

TR300VA002

300VA 10 Circuit Brkr.

480/240/208/120

24

· 2 End-Bell Openings 5.499" 3.750" 4.500" 3.859" 3.187" 2.526" 4.526"

TR375VA001

· 375VA 7

120

24

·

2 Bottom Openings 4.592" 3.747" 4.504" 3.933" 3.181" 2.516" 4.630"

FOR 20 - 50 VA TRANSFORMERS, SEE PREVIOUS PAGE.

For full product information, see data sheets on website.

= UL Listed - see data sheet for specific Listing

= UL Component Recognized - see data sheet for specific Listing

# = Refer to website for more wire length information ^ = Dual Terminal Secondary

130

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

SPECIALTY PERIPHERAL CONTROLS

RIBLB-6

RIBMNLB-2

SPECIALT Y PERIPHERAL CONTROLS

RIBMN24Q4C-PX
If we do not already build a device with specifications or packaging configurations you require, we will be happy to quote and design one for you. Functional Devices, Inc. is actively involved in the development, manufacturing, and production of special peripheral devices. They are either variations of existing Functional Devices products or entirely unique devices. We will help provide you with a product to

RIBMNA1D0
fit your specific needs. Please contact us so we may review your project and special requirements.
Air Handling Unit Fan Safety Shutdown
VIEW VIDEO

FAN SAFETY ALARM CIRCUITS / GENERAL PURPOSE LOGIC BOARDS

MODEL #

RIBMNLB

·

RIBLB

·

RIBMNWLB-7-BC ·

RIBMNLB-6

·

RIBMNLB-4

·

RIBMNLB-2

·

RIBMNLB-1

·

RIBLB-6

·

RIBLB-4

·

RIBLB-2

·

RIBMNLB-6NO

·

RIBMNLB-4NO

·

RIBMNLB-2NO

·

POWER INPUT 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc

ALARM CIRCUITS 4 4 7 6 4 2 1 6 4 2 6 4 2

COMPATIBLE
·

HOUSING STYLE * H D H H H H H D D D H H H

TRACK MOUNT INCLUDED MT212-6
MT212-6 MT212-6 MT212-4 MT212-4 MT212-4
MT212-6 MT212-4 MT212-4

SPEC PAGE 132 133 134 135 135 135 136 137 137 137 138 138 138

I/O EXPANDERS

MODEL #

RIBMN24Q2C

·

RIBMN24Q3C

·

RIBMN24Q4C

·

RIBMN24Q4C-PX

·

POWER INPUT 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc

RELAY CONTACTS 2 SPDT 3 SPDT 4 SPDT 4 SPDT

TRACK MOUNT INCLUDED MT212-4 MT212-4 MT212-6 MT212-6

SPEC PAGE 139 139 140 140

MANUAL ANALOG OVERRIDE SWITCH

MODEL # RIBMNA1D0

POWER INPUT 24 Vac/dc

SWITCH Manual / Auto

TRACK MOUNT ^ MT212 Series

SPEC PAGE 141

= UL Listed - see data sheet for specific Listing

* = See Housing Guide on page 201

^ = Track mount sold separately

(800) 888-5538 | www.functionaldevices.com

131

SPECIALT Y PERIPHERAL CONTROLS

FAN SAFETY ALARM CIRCUIT

RIBMNLB
AHU Fan Safety Alarm Circuit, 24 Vac/dc Power
Input, 2.75" Track Mount

Power Input
4A Max.

Dry Contact Inputs (From Field)

Powered Contact Outputs

2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 3A @ 24Vac /dc 750mA @ 24Vac/dc

1

2

24 Vac/dc

Power On

3

4

Low Limit

1

5

Static Pressure

Limit

1

6

Smoke

Detector/FA

Low Limit On

Static

Smoke

Pressure Detector/FA

On

On

Latched Input
Selector DIP
Switch
Latch Reset

Low Limit Relay

Static Pressure
Relay

Low Limit Static Pressure Digital In Digital In 10 11 12 13

1

7

Fan Status

Fan Status
On

1

8

24V Comm

Actuator Power

1

9

24V Comm

Fan Safety

Smoke Detector/ FA Relay

Fan Status Relay

Master Relay

Master Relay On

Smoke Detector/ Fan Status FA Digital In Digital In 14 15 16 17

For Indoor Use in Dry Locations

8A @ 24Vac/dc J1 Jumper 8A @ 24Vac/dc

8A @ 24Vac/dc 8A @ 24Vac/dc

Dry Contact Outputs (To Controller)

Dry Contact
Output 10A @ 277 Vac 10A @ 30 Vdc 1/2 HP@120/240Vac B300 Pilot Duty

CODE VER. 1.0

CAN BE USED TO ISOLATE FIELD DEVICES FROM EACH OTHER AND
FROM CONTROLLER, NOT ONLY FAN CIRCUITS

SPECIFICATIONS

Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 250ms Power Input: 4 Amp Max @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.00"H x 2.75"W x 0.75"D1/1.25"D2
Housing Detail: See Housing H in housing guide for dimensions
Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided
Approvals: UL Listed, UL864, C-UL, CE, RoHS, CSFM Gold Flash: No Override Switch: No
Notes: · RIBMNLB has four Alarm Inputs and one Master Alarm.
A master relay will open if any one of the normally-closed (N/C) inputs open. LED status of all outputs and the master relay is provided. The RIBMNLB is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB is enclosed in a NEMA 1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The master relay has two general-purpose outputs: one 24 V output terminal and one dry contact output rated up to 10 Amp @ 277 Vac. Fan status contact controls actuator power. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown.
Model RIBMNLB combines all the relay logic to facilitate fan status, fan safety control, and damper actuator control. It is intended for use in a circuit that will control fan start/stop and fan safety shut-down circuit monitors three critical inputs:
· Low-limit freeze protection (to stop fan and remove power from damper actuator)
· Static pressure (to monitor for hi/low pressure condition)
· Smoke detector / fire alarm
Master relay opens to shut down AHU when any Normally Closed input opens.
Integral DIP switch allows any input to be latched. Input can be reset with push button or by cycling unit power.
Installing J1 jumper allows Fan Status input to control Master Relay, like the other 3 inputs.

Panel

Black Black

RC-1 5Amp

White White Green

TX-1

1 x 1

24Vac

1 x 2

DC-1 Power

24Vac COM

DC-1 DO-3

Digital inputs to controller 1 R4 FS-S 24Vac
16 Fan Status DI
17
R1 LL-A 10 Low Limit DI 11
R2 SP-A 12 Static Press Alarm DI 13
R3 Smoke/Fire Alarm 14 Smoke / Fire Alarm DI 15

DL-1

2 24Vac R1 LL-A R2 SP-A R3 SMK/FA 1
9

PB-1

R1 LL-A

R1 LL-A

3

4

1 5
R2 SP-A
1 6
R3 SMK/FA

1

R4 FS-S

7

RIBMNLB (Track Mount)
RIBLB (Enclosed)

At power-up, delay 2 sec before DL-1 becomes activated

R4 FS-S

1

8

DL-1

Field

H 120Vac
N Emergency Power G with ground

X1

120Vac

X2

Starter H O A Contactor Ols

RIBTU2C

Wht/Blu

Blu

Yel

Wht/Yel

Org

Gry/Wht

Gry

Prp

Wht/Prp

Brn

Fan Safety Relay

Low Limit

Static Pressure

Smoke Detector / Fire Alarm Tn

To Motor
Status FS-S
RIBX Series

Fan Status

Actuator Power

This drawing represents: · Only Low Limit Latch Set · J1 Jumper Not Installed

132

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

SPECIALT Y PERIPHERAL CONTROLS

FAN SAFETY ALARM CIRCUIT

RIBLB
AHU Fan Safety Alarm Circuit, 24 Vac/dc Power
Input, NEMA 1 Housing

Power Input

Dry Contact Inputs (From Field)

Powered Contact Outputs

4A Max.

2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 3A @ 24Vac /dc 750mA @ 24Vac/dc

1

2

24 Vac/dc

Power On

3

4

Low Limit

1

5

Static Pressure

Limit

1

6

Smoke

Detector/FA

Low Limit On

Static

Smoke

Pressure Detector/FA

On

On

Latched Input
Selector DIP
Switch
Latch Reset

Low Limit Relay

Static Pressure
Relay

Low Limit Static Pressure Digital In Digital In 10 11 12 13

1

7

Fan Status

Fan Status
On

1

8

24V Comm

Actuator Power

1

9

24V Comm

Fan Safety

Smoke Detector/ FA Relay

Fan Status Relay

Master Relay

Master Relay On

Smoke Detector/ Fan Status FA Digital In Digital In 14 15 16 17

For Indoor Use in Dry Locations

8A @ 24Vac/dc J1 Jumper 8A @ 24Vac/dc

8A @ 24Vac/dc 8A @ 24Vac/dc

Dry Contact Outputs (To Controller)

SPECIFICATIONS

Dry Contact
Output 10A @ 277 Vac 10A @ 30 Vdc 1/2 HP@120/240Vac B300 Pilot Duty

CODE VER. 1.0

CAN BE USED TO ISOLATE FIELD DEVICES FROM EACH OTHER AND
FROM CONTROLLER, NOT ONLY FAN CIRCUITS

Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 250ms Power Input: 4 Amp Max @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple
Housing Detail: See Housing D in housing guide for dimensions
Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided
Approvals: UL Listed, UL864, C-UL, CE, RoHS, CSFM Housing Rating: UL Listed, NEMA 1, C-UL, CE
Gold Flash: No Override Switch: No

Panel

Black Black

RC-1 5Amp

White White Green

TX-1

1 x 1

24Vac

1 x 2

DC-1 Power

24Vac COM

DC-1 DO-3

Notes: · RIBMNLB and RIBLB have four Alarm Inputs and one Master Alarm.
A master relay will open if any one of the normally-closed (N/C) inputs open. LED status of all outputs and the master relay is provided. The RIBMNLB is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB is enclosed in a NEMA 1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The master relay has two general-purpose outputs: one 24 V output terminal and one dry contact output rated up to 10 Amp @ 277 Vac. Fan status contact controls actuator power. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown.
Model RIBMNLB combines all the relay logic to facilitate fan status, fan safety control, and damper actuator control. It is intended for use in a circuit that will control fan start/stop and fan safety shut-down circuit monitors three critical inputs:
· Low-limit freeze protection (to stop fan and remove power from damper actuator)
· Static pressure (to monitor for hi/low pressure condition)
· Smoke detector / fire alarm
Master relay opens to shut down AHU when any Normally Closed input opens.
Integral DIP switch allows any input to be latched. Input can be reset with push button or by cycling unit power.
Installing J1 jumper allows Fan Status input to control Master Relay, like the other 3 inputs.

Digital inputs to controller 1 R4 FS-S 24Vac
16 Fan Status DI
17
R1 LL-A 10 Low Limit DI 11
R2 SP-A 12 Static Press Alarm DI 13
R3 Smoke/Fire Alarm 14 Smoke / Fire Alarm DI 15

DL-1

2 24Vac R1 LL-A R2 SP-A R3 SMK/FA 1
9

PB-1

R1 LL-A

R1 LL-A

3

4

1 5
R2 SP-A
1 6
R3 SMK/FA

1

R4 FS-S

7

RIBMNLB (Track Mount)
RIBLB (Enclosed)

At power-up, delay 2 sec before DL-1 becomes activated

R4 FS-S

1

8

DL-1

Field

H 120Vac
N Emergency Power G with ground

X1

120Vac

X2

Starter H O A Contactor Ols

RIBTU2C

Wht/Blu

Blu

Yel

Wht/Yel

Org

Gry/Wht

Gry

Prp

Wht/Prp

Brn

Fan Safety Relay

Low Limit

Static Pressure

Smoke Detector / Fire Alarm Tn

To Motor
Status FS-S
RIBX Series

Fan Status

Actuator Power

This drawing represents: · Only Low Limit Latch Set · J1 Jumper Not Installed

(800) 888-5538 | www.functionaldevices.com

133

SPECIALT Y PERIPHERAL CONTROLS

FAN SAFETY ALARM CIRCUIT

RIBMNWLB-7-BC
AHU Fan Safety Alarm and General Purpose Logic Circuit, BACnet MS/TP Network, 24 Vac/dc Power Input, Two Binary Outputs + Override, Seven Binary Inputs, 2.75" Track Mount
BI 5 - BI 7

Clear Latches Pushbutton
BI Latched Indicator

BI 7

BI 6

BI 5

Power/Stat

CLOSED 123456

CLOSED 123456

OPEN
CLOSE TO OVERRIDE BI 1-BI 6

OPEN CLOSE TO MAKE
LATCHING INPUT BI 1-B1 6

MSB 1 2 3 4 5 6
LSB 7 8 9
10

BACnet MSTP

1 2 3 4 5 6 7 8 9 10

CLOSED CLOSED

12

12

OPEN

OPEN

ON

ON

OFF

OFF

AUTO

AUTO

BO 1-1

BO 1-2

Power Input BO 2

RIBMNWLB-7-BC

BI 1

BI 2

BI 3

BI 4

B(+) A(-) REF

24V 24V 24V 24V COMM COMM

N/C C N/O

N/C N/O C

BI 1 - BI 4
SPECIFICATIONS

Expected Relay Life: 10 million cycles minimum mechanical

Operating Temperature: -30 to 140° F

Humidity Range: 5 to 95% (noncondensing)

Operate Time: 8ms

Power Input: 24 Vac/dc: 50-60 Hz

Max current input determined by adding load

current user applies to BO 1-1 (3A Max) plus 75 mA @ 24

Vac or 30 mA @ 24 Vdc depending on power source sup-

plied by user to power RIB device, 24 Vac or 24 Vdc

Dimensions: 6.62"H x 2.75"W x 1.25"D1/1.75"D2

Housing Detail: See Housing H in housing guide for dimensions

Origin: Made of US and non-US parts

Approvals: UL864, UL916, C-UL, CE, RoHs, CSFM

Relay Rating, BO 1-1: 3 Amp Max @ 24 Vac or 24 Vdc (depending on power

source supplied by user to power RIB device)

Relay Rating, BO 1-2: 10 Amp Resistive @ 30 Vdc

10 Amp General Use @ 277 Vac

1/2 HP @ 120/240 Vac

Relay Rating, BO 2: 20 Amp Resistive @ 277 Vac

5 Amp @ 480 Vac

20 Amp Ballast @ 277 Vac

16 Amp Electronic Ballast @ 277 Vac

1 HP @ 120 Vac

2 HP @ 277 Vac

Relay Override Switch: DIP Switch Control

Network Media: Twisted Pair 22-24AWG, shielded recommended

Terminations: Functional Devices product installed at both ends of the

MS/TP network ­ Use 120  end of line resistors. All other

cases ­ Follow instructions from the device installed at the

end of the MS/TP network.

Polarity: Network is polarity sensitive

Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch

Notes:

Selectable)

· When connecting 24 Vac to both the RIB(s) and a half-wave device, damage

to device can occur.

· Option 1: Use separate transformers for each device.

Option 2: Add diode between devices, see Option 2 note below. ^^

Dry-Contact-Output Rated Up to 10A @ 277Vac
3A Max from 24V Input Supply

BO 1-2 BO 1-1

BO 2 Dry-Contact Ouput Rated Up to 20A @ 277Vac, 5A @ 480Vac

R1-1 R2-1 R3-1 R4-1 R5-1 R6-1

ON OFF AUTO BO 1
BO 1 Indicator

24 Vac/dc Supply Input

BO 2 BI 7 Indicator

ON OFF AUTO
BO 2 BI 7
BO 2 Indicator

Fan Current Stat

BI Latch Select DIP Switches

Indicators

BI Override DIP Switches

BI 1 Latch

BI 1 Override

R1

R1-2 BI 1 Indicator

BI 2 Latch

BI 2 Override

R2

R2-2 BI 2 Indicator

BI 3 Latch

BI 3 Override

R3

R3-2 BI 3 Indicator

BI 4 Latch

BI 4 Override

R4

R4-2 BI 4 Indicator

BI 1-BI 6

BI 1

Low Temp Alarm

BI 2

High Temp Alarm

BI 3

Low Pres Alarm

BI 4

High Pres Alarm

BI 5 Latch

BI 5 Override

R5

R5-2 BI 5 Indicator

BI 6 Latch

BI 6 Override

R6

R6-2 BI 6 Indicator

BI 5

Smoke Alarm #1

BI 6

Smoke Alarm #2

· The RIBMNWLB-7-BC is set in Fan-Safety-Circuit mode by default from the factory. Fan-Safety-Circuit mode sets up BI 1 ­ BI 6 in an AND function, so that when all 6 binary inputs are closed, BO 1 will close. Opening any of the 6 binary inputs will open BO 1.
· BO 2 is bound to BI 7 such that when BI 7 is closed, BO 2 relay will activate. Binding and Priority level can be set by properties in BO 2.
· The RIBMNWLB-7-BC can also be enabled as an I/O board with 2 binary output relays and 7 general-purpose binary inputs.

RIBMNWLB-7-BC or RIBTWLB-7-BC

Half-Wave Device

24 Vac

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

BACnet® Details:

· MS/TP Address & Baud Rate must be set prior to power up via DIP switches.

· Device ID will default to 277XXX where XXX is the MS/TP Address.

Examples: MS/TP Address - 004 MS/TP Address - 121

Device ID - 277004

Device ID - 277121

· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.)

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

BAUD RATE

9600 19200 38400 57600 76800 115200

All other combinations = 9600 baud
* 0 = Open ; 1 = Closed

134

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

SPECIALT Y PERIPHERAL CONTROLS

FAN SAFETY ALARM CIRCUITS

RIBMNLB-6/-4/-2
AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input,
6/4/2 Alarm Inputs all with N/C Outputs, 2.75" Track Mount

Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc

3A Total Sourced from 24 Vac/dc Input

R7 N/O POLE 2 R7 N/O POLE 1

R7 N/O POLE 1

R1 OUT N/C
R1

R2 OUT N/C
R2

R3 OUT N/C
R3

R4 OUT N/C
R4

R5 OUT N/C
R5

COM N/O COM N/O
R6 OUT N/C
R6 R7

10A @ 277 Vac 10A @ 24 Vdc 1/2 HP @ 120/240 Vac B300 Pilot Duty
Max. Isolated Dry
Contact Output

R1-R6 N/C INPUTS

R1 R2 CLOSE
OPEN

R3 R4 CLOSE
OPEN

R5 R6 CLOSE
OPEN

24 COM Vac/dc

Alarm Input 1

Alarm Input 2

Alarm Input 3

Alarm Input 4

Alarm Input 5

Each Input Pulls 39mA from 24 V Input

Alarm Input 6

4A Max Power Input

Green LED 24 V Power

Master Alarm Indicator

SPECIFICATIONS

Expected Relay Life: 10 million cycles minimum mechanical

Operating Temperature: -30 to 140° F

Humidity Range: 5 to 95% (noncondensing)

Operate Time: 8ms

Power Input: 4 Amp max. @ 24 Vac/dc ; 50-60 Hz

Alarm Status: LED On = Activated Dimensions: 6.20"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-6)

10A @ 277 Vac

R7-2

4.60"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-4)

(Typically used to shut down fan)

3.00"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-2)

Hosuing Detail: See Housing H in housing guide for dimensions

R7-1

Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided (RIBMNLB-6)

24 Vac (Typically used to shut down

MT212-4 Mounting Track Provided

other relays)

(RIBMNLB-4, RIBMNLB-2)

R1-2

Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS, CSFM

Low Temp Alarm

Gold Flash: No

to DDC Controller

Override Switch: No

Notes: · Track mount models shown above. · RIBMNLB-6 has six Alarm Inputs and one Master Alarm. · RIBMNLB-4 has four Alarm Inputs and one Master Alarm. · RIBMNLB-2 has two Alarm Inputs and one Master Alarm. · This is a half wave device. When connecting 24Vac to both this device and a full wave device, damage to devices can occur.

R2-2 High Temp Alarm to DDC Controller
R3-2 Low Press Alarm to DDC Controller

Models RIBMNLB-6, RIBMNLB-4, and RIBMNLB-2 are simply devices that combine a common relay-logic function into a small, easy-toinstall, and less expensive form.

A master relay will open if any one of the normally-closed (N/C) inputs

R4-2

open. There are six, four, or two inputs depending on the model

High Press Alarm to DDC Controller

chosen. LED status of all inputs, the master relay, and power input

is provided. Bypass of un-used inputs is also provided. The RIBMNLB

series is provided with mounting track for mounting in user-provided

electrical enclosures. The RIBLB series is enclosed in a NEMA-1, 4 x

7 enclosure with a clear lid to allow viewing of the status LEDs. The

Smoke Alarm #1

R5-2

master relay has three general-purpose outputs: two 24 V output

to DDC Controller

terminals and one dry-contact output rated up to 10 Amp @ 277 Vac

(terminals on RIBMNLB series, wires on RIBLB series.) The most com-

mon application is an Air Handling Unit (AHU) fan-safety-shutdown

where the master relay is used to shutdown the fan. Contact closure

R6-2

outputs are provided so that a DDC controller can determine the

Smoke Alarm #2

cause of a shutdown.

to DDC Controller

SELECTION GUIDE

Model#

Inputs

RIBMNLB-6

6

MT212 Mounting Track

RIBMNLB-4

4

MT212 Mounting Track

RIBMNLB-2

2

MT212 Mounting Track

24 Vac Power Input

R1-1 R2-1 R3-1 R4-1 R5-1 R6-1 R7

Close bypass switch if input not in use.

Input 1 Bypass

R1

R1-3 Input 1 Alarm Indicator

Typical alarm inputs shown below. Any alarm inputs may be used and in any order. (Alarm inputs must be N/C.)
Input 1 Low Temp Alarm

Input 2 Bypass

R2

R2-3 Input 2 Alarm Indicator

Input 2 High Temp Alarm

Input 3 Bypass

R3

R3-3 Input 3 Alarm Indicator

Input 3 Low Press Alarm

Input 4 Bypass

R4

R4-3 Input 4 Alarm Indicator

Input 4 High Press Alarm

Input 5 Bypass

R5

R5-3 Input 5 Alarm Indicator

Input 5 Smoke Alarm #1

Input 6 Bypass

R6

R6-3 Input 6 Alarm Indicator

RIBMNLB-6 (Track Mount) RIBLB-6 (Enclosed)

Input 6 Smoke Alarm #2

(800) 888-5538 | www.functionaldevices.com

135

Power Input

24 Vac/dc Comm

FAN SAFETY ALARM CIRCUIT
RIBMNLB-1
General Purpose Latching Logic Circuit, One Latching/Fault Input, One Relay Output, 24 Vac/dc Power Input, 2.75" Track Mount
Latch/Fault Input
RESET Pushbutton
Power Latch/Fault Status Status

· MANUAL RESET · ONE ALARM OUTPUT · ONE RELAY OUTPUT

N/C C N/O N/O C N/C

SPECIALT Y PERIPHERAL CONTROLS

SPECIFICATIONS

# Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Green LED: Power Status (ON: Power present) Red LED: Fault Status (ON: Latched/Fault State) Dimensions: 3.00"H x 2.75"W x 0.75"D1/1.25"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-4 Mounting Track Provided Approvals: CE, UL Listed, UL864, C-UL, RoHS, CSFM Gold Flash: No
Relay Override Switch: No Fault Reset Switch: Yes

Contact Ratings: 10 Amp Resistive @ 30Vdc 10 Amp General Use @ 277Vac 1/2 HP @ 120/240Vac (N/O) 1/3 HP @ 120/240Vac (N/C)
Power Input Ratings: 53 mA @ 24Vac 25 mA @ 24Vdc 50/60 Hz

H

24 Vac

N

Safety Latch Circuit Application

LATCH RESET
PB1 NC

BI R

LT-A

BLK

Auto-reset

24 VAC/DC H N

L

Power

Indicator

Fault Input

Latch Circuit

RIBMNLB-1
Circuit must latch on power up. Circuit must not relatch before or after fault has been cleared. Circuit must only relatch when power is reset.

L Alarm Indicator LR1
LR1-1
LR1-2 LR1-3
LR1-4

Output

Alarm Fault Application: When the Latch/Fault Input is Closed (Normal state), the Relay is activated, and Red LED is Off. When Latch/Fault Input Opens (Alarm state), the Relay deactivates, and Red LED turns On. Until the Latch/ Fault Input is Closed AND either power is cycled or the RESET button is pressed, relay will remain in the Alarm state.
Notes: · Fault conditions must last for at least 500 ms in order for the
unit to go into Alarm state. · Reset signal, whether via pushbutton or power cycling, must
last for at least 30 ms in order to reset the device to go from Alarm state to Normal state.

HP-A

BI

R 12

BLK

P Man-reset

LP-A

BI

R 12

BLK

P Man-reset

BI

HT-A

R 12

BLK

Man-reset

24 VAC H N

L

Power Indicator

R5-2
R5-3 L

R1-1

R2-1

R3-1

R4-1

R5

R4-1

Fault Input 1

Input 1 Bypass

Fault Input 2

Input 2 Bypass

Fault Input 3

Input 3 Bypass

Fault Input 4

Input 4 Bypass

RIBMNLB-4 (ordered separately)

R1 R1-3
L R1-2
R2 R2-3
L R2-2
R3 R3-3
L R3-2
R4 R4-3
L R4-2

Master Power Indicator

Typically Used for Fan Shutdown

2046

BI

BC

LOCATED IN

R

EAD-ES

BLK

Alarm Indicator
LT-A Status

Alarm Indicator
HP-A Status
Alarm Indicator
LP-A Status
Alarm Indicator
HT-A Status

Typical Field Interlock Wiring

2046 DA

4054 AD
4054 AD

LOCATED IN SUPPLY FAN MCC PANEL FAN #1.

BO

A1 SDR-1 A2

R

BLK

N.O.

C

4054 CB

LOCATED IN SUPPLY FAN MCC PANEL FAN #2.

BO

A1 SDR-1a A2

R

BLK

N.O.

C

4054 CB

LOCATED IN RETURN / EXHAUST FAN MCC PANEL FAN #1.

4055 AD

BO

A1 SDR-2 A2

R

BLK

4055 CB

N.O.

C

LOCATED IN RETURN / EXHAUST FAN MCC PANEL FAN #2.

4055 AD

BO

A1 SDR-2a A2

R

BLK

4055 CB

N.O.

C

136

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

SPECIALT Y PERIPHERAL CONTROLS

FAN SAFETY ALARM CIRCUITS
RIBLB-6/-4/-2
AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input, 6/4/2 Alarm Inputs all with N/C Outputs, NEMA 1 Housing
Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc

3A Total Sourced from 24 Vac/dc Input

R7 N/O POLE 2 R7 N/O POLE 1

R7 N/O POLE 1

R1 OUT N/C
R1

R2 OUT N/C
R2

R3 OUT N/C
R3

R4 OUT N/C
R4

R5 OUT N/C
R5

COM N/O COM N/O
R6 OUT N/C
R6 R7

10A @ 277 Vac 10A @ 24 Vdc 1/2 HP @ 120/240 Vac B300 Pilot Duty
Max. Isolated Dry
Contact Output

R1-R6 N/C INPUTS

R1 R2 CLOSE
OPEN

R3 R4 CLOSE
OPEN

R5 R6 CLOSE
OPEN

24 COM Vac/dc

Alarm Input 1

Alarm Input 2

Alarm Input 3

Alarm Input 4

Alarm Input 5

Each Input Pulls 39mA from 24 V Input

Alarm Input 6

4A Max Power Input

Green LED 24 V Power

Master Alarm Indicator

SPECIFICATIONS

Expected Relay Life: 10 million cycles minimum mechanical

Operating Temperature: -30 to 140° F

Humidity Range: 5 to 95% (noncondensing)

Operate Time: 8ms

Power Input: 4 Amp max. @ 24 Vac/dc ; 50-60 Hz

Alarm Status: LED On = Activated

Dimensions: 4.28H x 7.00W x 2.00D with .75 NPT Nipple Housing Detail: See Housing D in housing guide

10A @ 277 Vac (Typically used to

R7-2

for dimensions

shut down fan)

Origin: Made of US and non-US parts

Track Mount: MT212-6 Mounting Track Provided (RIBMNLB-6)

R7-1

MT212-4 Mounting Track Provided

24 Vac (Typically used

(RIBMNLB-4, RIBMNLB-2)

to shut down

Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS, CSFM

other relays)

Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved,

R1-2

UL Accepted for Use in Plenum

Low Temp Alarm

Gold Flash: No

to DDC Controller

Override Switch: No

Notes:

· Track mount models shown above. · RIBLB-6 have six Alarm Inputs and one Master Alarm. · RIBLB-4 have four Alarm Inputs and one Master Alarm.

R2-2
High Temp Alarm to DDC Controller

· RIBLB-2 have two Alarm Inputs and one Master Alarm.

· This is a half wave device. When connecting 24Vac to both this

device and a full wave device, damage to devices can occur.

R3-2

Low Press Alarm

Models RIBLB-6, RIBLB-4, and RIBLB-2 are simply devices that combine

to DDC Controller

a common relay-logic function into a small, easy-to-install, and less

expensive form.

A master relay will open if any one of the normally-closed (N/C) inputs

open. There are six, four, or two inputs depending on the model

High Press Alarm

R4-2

chosen. LED status of all inputs, the master relay, and power input

to DDC Controller

is provided. Bypass of un-used inputs is also provided. The RIBMNLB

series is provided with mounting track for mounting in user-provided

electrical enclosures. The RIBLB series is enclosed in a NEMA-1, 4 x

7 enclosure with a clear lid to allow viewing of the status LEDs. The

R5-2

master relay has three general-purpose outputs: two 24 V output

Smoke Alarm #1

terminals and one dry-contact output rated up to 10 Amp @ 277 Vac

to DDC Controller

(terminals on RIBMNLB series, wires on RIBLB series.) The most com-

mon application is an Air Handling Unit (AHU) fan-safety-shutdown

where the master relay is used to shutdown the fan. Contact closure

outputs are provided so that a DDC controller can determine the

R6-2

cause of a shutdown.

Smoke Alarm #2 to DDC Controller

SELECTION GUIDE

Model#

Inputs

RIBLB-6

6

RIBLB-4

4

RIBLB-2

2

PE6020 Enclosure PE6020 Enclosure PE6020 Enclosure

24 Vac Power Input

R1-1 R2-1 R3-1 R4-1 R5-1 R6-1 R7

Close bypass switch if input not in use.

Input 1 Bypass

R1

R1-3 Input 1 Alarm Indicator

Typical alarm inputs shown below. Any alarm inputs may be used and in any order. (Alarm inputs must be N/C.)
Input 1 Low Temp Alarm

Input 2 Bypass

R2

R2-3 Input 2 Alarm Indicator

Input 2 High Temp Alarm

Input 3 Bypass

R3

R3-3 Input 3 Alarm Indicator

Input 3 Low Press Alarm

Input 4 Bypass

R4

R4-3 Input 4 Alarm Indicator

Input 4 High Press Alarm

Input 5 Bypass

R5

R5-3 Input 5 Alarm Indicator

Input 5 Smoke Alarm #1

Input 6 Bypass

R6

R6-3 Input 6 Alarm Indicator

RIBMNLB-6 (Track Mount) RIBLB-6 (Enclosed)

Input 6 Smoke Alarm #2

(800) 888-5538 | www.functionaldevices.com

137

SPECIALT Y PERIPHERAL CONTROLS
To DDC Controller

FAN SAFETY ALARM CIRCUITS

RIBMNLB-6NO/-4NO/-2NO

AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input, 6/4/2 Alarm Inputs all with N/O

Outputs, 2.75" Track Mount

3A Total Sourced

Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc

from 24 Vac/dc Input or Dry Contact (Jumper Selectable)

R1 OUT N/O

R2 OUT N/O

R3 OUT N/O

R4 OUT N/O

R5 OUT N/O

R6 OUT N/O

R7

R7

POLE 1 POLE 2

R1

R2

Alarm

Input

Indicators

CLOSED

12

R3

R4

CLOSED 34

R5

R6

Master

Relay

R7

CLOSED 56

R1 R1 COM OPEN R2 R2 COM R3 R3 COM OPEN R4 R4 COM R5 R5 COM OPEN R6 R6 COM

COMM 24V

Alarm Input 1

Alarm Input 2

Alarm Input 3

Alarm Input 4

Alarm Input Bypass Switches

Alarm Input 5

Alarm Input 6

4A Max

Master Alarm Indicator
24V Power
Legend for Jumper Selection Dry =
24V =

SPECIFICATIONS

Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Power Input: 4 Amp max. @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.20"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-6NO) 4.60"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-4NO) 3.00"H x 2.75"W x 1.25"D1/1.75"D2 (RIBMNLB-2NO)
Housing Detail: See Housing H in housing guide for dimensions
Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided (RIBMNLB-6NO)
MT212-4 Mounting Track Provided (RIBMNLB-4NO, RIBMNLB-2NO) Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS, CSFM Gold Flash: No Override Switch: No

Input 1

24 Vac Input Power Comm
24 V

R1-3 Input 2

R2-3 Input 3

R3-3 Input 4

24 Vac Preset Indicator

R1 R1 Alarm Indicator

R2

R2 Alarm Indicator

R3

R3 Alarm Indicator

R1-2

R4 R2-2

Models RIBMNLB-6NO, RIBMNLB-4NO, and RIBMNLB-2NO are simply devices that combine a common relay-logic function into a small, easy-to-install, and less expensive form.
A master relay will open if any one of the normally-closed (N/C) inputs open. There are six, four, or two inputs depending on the model chosen. LED status of all inputs, the master relay, and power input is provided. Bypass of un-used inputs is also provided. The RIBMNLB series is provided with mounting track for mounting in user-provided electrical enclosures.

Input 5 Input 6

R4-3

R4 Alarm Indicator

R5

R3-2

R5-3

R5 Alarm Indicator

R4-2 R6

R6-3

R6 Alarm Indicator R5-2

R1-1

R2-1

R3-1

R4-1

R5-1

R6-1 R7

Input 1

Input 2

Input 3

Input 4

Input 5

Input 6

R6-2

Bypass

Bypass

Bypass

Bypass

Bypass

Bypass

The master relay has two general-purpose outputs: both can be jumper selected at 24 V (sourced from input) or dry contact. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown.

R7-3
R7-1 Output Con guration Jumper Dry Contact Wet Contact
P1 P2 P3 P4

R7 Alarm Indicator

Notes: · RIBMNLB-6NO has six Alarm Inputs and one Master Alarm. · RIBMNLB-4NO has four Alarm Inputs and one Master Alarm. · RIBMNLB-2NO has two Alarm Inputs and one Master Alarm.
· This is a half wave device. When connecting 24 Vac to both this device and a full-wave device, damage to device can occur.

R7-2 Output Con guration Jumper

R7-1

Dry Contact

Wet Contact P5 P6 P7 P8

SELECTION GUIDE

Model#

Inputs

RIBMNLB-6NO

6

MT212 Mounting Track

RIBMNLB-4NO

4

MT212 Mounting Track

RIBMNLB-2NO

2

MT212 Mounting Track

R7-2 RIBMNLB-6NO

138

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

I/O EXPANDER
RIBMN24Q2C
I/O Expander, 2 Outputs, 24 Vac/ dc Power Input, 0-10 Vdc / 0-5 Vdc Control Input, 2.75"Track Mount

AI Com

0-10 Vdc / 0-5 Vdc

24 Vac/dc

Comm

*

Relay 1

Relay 2

0-10 VDC CONTROL VOLTAGE
0-2.117Vdc

0-5 VDC * CONTROL VOLTAGE
0-1.058Vdc

RELAY 1
STATUS
OFF

RELAY 2
STATUS
OFF

2.745-4.627Vdc 1.373-2.313Vdc ON

OFF

5.255-7.137Vdc 2.628-3.568Vdc OFF

ON

7.765-10.000Vdc 3.883-5.000Vdc ON

ON

N/O

C

N/C

N/O

C

N/C

SPECIFICATIONS
# Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 3.10"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-4 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No
I/O EXPANDER

GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS,
OR MULTI-STAGE HEATING

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac

Power Input: 24 Vac/dc ; 50-60 Hz 100mA max.
Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders.

RIBMN24Q3C
I/O Expander, 3 Outputs, 24 Vac/dc Power Input, 0-10 Vdc / 0-5 Vdc Control Input, 2.75" Track Mount

SPECIALT Y PERIPHERAL CONTROLS

AI Com

0-10 Vdc

/ 0-5 Vdc

24 Vac/dc

Comm

0-10 VDC 0-5 VDC * RELAY RELAY RELAY

CONTROL CONTROL 1

2

3

VOLTAGE VOLTAGE STATUS STATUS STATUS

*

0-0.988Vdc

0-0.494Vdc

OFF

OFF

OFF

1.366-2.242Vdc 0.683-1.121Vdc

ON

OFF

OFF

2.620-3.496Vdc 1.310-1.748Vdc

OFF

ON

OFF

Relay 1

Relay 2

Relay 3

3.876-4.752Vdc 1.938-2.376Vdc

ON

ON

OFF

5.130-6.006Vdc 2.565-3.003Vdc

OFF

OFF

ON

N/O

C

N/C

SPECIFICATIONS

N/C C N/O

N/O

C

N/C

6.386-7.262Vdc 3.193-3.631Vdc

ON

OFF

ON

7.640-8.516Vdc 3.820-4.258Vdc

OFF

ON

ON

GREAT FOR STAGING LOADS SUCH

AS CHILLERS, PUMPS, ACTUATORS,

8.896-10.000Vdc 4.448-5.000Vdc

ON

ON

ON

OR MULTI-STAGE HEATING

# Relays & Contact Type: Three (3) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 4.00"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-4 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac

Power Input: 24 Vac/dc ; 50-60 Hz 150mA max.
Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders.

(800) 888-5538 | www.functionaldevices.com

139

SPECIALT Y PERIPHERAL CONTROLS

I/O EXPANDER

RIBMN24Q4C
I/O Expander, Four Outputs, 24 Vac/dc Power, 0-10 Vdc /
0-5 Vdc Control Input, 2.75" Track Mount

0-10 VDC CONTROL VOLTAGE
0-0.372Vdc

0-5 VDC *
CONTROL VOLTAGE 0-0.186Vdc

RELAY RELAY RELAY RELAY

1

2

3

4

STATUS STATUS STATUS STATUS

OFF

OFF

OFF

OFF

AI Com

0-10 Vdc

/ 0-5 Vdc

24 Vac/dc

Comm

0.726-1.000Vdc 0.363-0.500Vdc ON

OFF

OFF

OFF

1.354-1.626Vdc 0.677-0.813Vdc OFF

ON

OFF

OFF

1.982-2.254Vdc 0.991-1.127Vdc ON

ON

OFF

OFF

*

2.608-2.882Vdc 1.304-1.441Vdc OFF

OFF

ON

OFF

3.236-3.508Vdc 1.618-1.754Vdc ON

OFF

ON

OFF

3.864-4.136Vdc 1.932-2.068Vdc OFF

ON

ON

OFF

Relay 1

Relay 2

Relay 3

Relay 4

4.492-4.764Vdc 2.246-2.382Vdc ON

ON

ON

OFF

5.118-5.392Vdc 2.559-2.696Vdc OFF

OFF

OFF

ON

5.746-6.018Vdc 2.873-3.009Vdc ON

OFF

OFF

ON

6.374-6.646Vdc 3.187-3.323Vdc OFF

ON

OFF

ON

N/C

C

N/O

N/C C N/O
N/C C N/O

N/C

C

N/O

7.000-7.274Vdc 3.500-3.637Vdc ON

ON

OFF

ON

7.628-7.902Vdc 3.814-3.951Vdc OFF

OFF

ON

ON

8.256-8.528Vdc 4.128-4.264Vdc ON

OFF

ON

ON

8.884-9.156Vdc 4.442-4.578Vdc OFF

ON

ON

ON

SPECIFICATIONS

9.510-10.000Vdc 4.755-5.000Vdc

# Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 4.95"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Origin: Made of US and non-US parts

ON

ON

ON

ON

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac

GREAT FOR STAGING LOADS SUCH AS
CHILLERS, PUMPS, ACTUATORS, OR
MULTI-STAGE HEATING
Power Input: 24 Vac/dc ; 50-60 Hz 200mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders.

I/O EXPANDER

RIBMN24Q4C-PX
Field Adjustable Staging Threshold Relay Module, 4 Outputs,
24 Vac/dc Power Input, 0-10 Vdc Control Input, 2.75" Track Mount

24 Vac/dc Comm

Power
}Input

Setup Display

DN UP

Relay 1

Relay 2

Relay 3

Relay 4

N/O

N/C C N/O
N/C C N/O

N/C

C N/O

SPECIFICATIONS

N/C C

Analog
}Input

(+)

AI Com (­)
0-10 Vdc

· CONTROL FOUR RELAY OUTPUTS WITH ONE (0-10 VDC) ANALOG SIGNAL FROM CONTROLLER OR THERMOSTAT
· CAPABILITY TO SET DESIRED ON AND OFF VOLTAGES FOR EACH RELAY
· NO POTS TO ADJUST
· NO NEED FOR VOLT METER FOR SETUP
· ON BOARD "FIELD SELECTABLE" DIGITAL DISPLAY

# Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Heartbeat Status: Right-most decimal point Dimensions: 4.95"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No

Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac
Power Input: 24 Vac/dc ; 50-60 Hz 200mA max.

Notes: · For AC applications, an isolation transformer, to be used solely for the power input, is recommended. · Relay will activate when control signal voltage reaches or exceeds individual relay ON point. Relay will deactivate when control voltage reaches or drops below individual OFF point. · Factory relay ON / OFF voltages: · Relay 1: 3V / 2.8V
· Relay 2: 5V / 4.8V · Relay 3: 7V / 6.8V · Relay 4: 9V / 8.8 V · Minimum ON point: 0.5V · Maximum ON point: 9.9V · Minimum OFF point: 0.3V · Relay number will flash 3 times when voltage exceeds setpoint. · Pressing UP or DN button in normal run mode will display the voltage present on Analog Input. · ON/OFF points can be changed at any time, by the user, by entering "Program Mode" · User defined ON/OFF points will be maintained upon power loss.

140

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

MANUAL ANALOG OVERRIDE SWITCH

RIBMNA1D0
Manual Analog Override Switch + Monitor, 24 Vac/dc Power Input, 2.75" Track Mount

Signal + Signal ­ Power ­ Power +

Manual Auto

80% 60% 40% 20%
­ + Potentiometer

­ Output + Output

Feedback

Legend for Selecting Output for Jumpers
Top 2 pins covered by jumper Bottom 2 pins covered by jumper Only 1 pin covered by jumper
5 Vdc 10 Vdc 15 Vdc 20 mA

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 2.45"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 2.750", MT212 Mounting Track Sold Separately Input Voltage: 24 Vac/dc Input Current: 90mA Max.
Range/Impedance Override: 0-5 Vdc, 200  Min. 0-10 Vdc, 400  Min. 0-15 Vdc, 1 k Min. 0-20mA dc, 500  Max.
Feedback Contact: 2A Max. @ 24 Vac/dc

Notes: · Set the jumpers according to your input signal (Analog signal from the controller.) Example: When controlling a damper with 0-10 Vdc, the jumpers need to be in position for the 0-10 Vdc override range. If the LED range does not match your analog scale, ensure the jumpers are set for the proper range. · Feedback contact closed when switch is in Manual position, open when switch is in Auto position.
· PROVIDES MANUAL OVERRIDE IF CONTROLLER DOES NOT SUPPORT OVERRIDE CAPABILITY
· ALLOWS YOU TO MANUALLY MAKE ADJUSTMENTS TO YOUR END DEVICE REMOTELY INSTEAD OF AT YOUR CONTROL PANEL
· SENDS OVERRIDE STATUS BACK TO CONTROLLER VIA FEEDBACK · MULTI-RANGE ANALOG OUTPUT

SPECIALT Y PERIPHERAL CONTROLS

(800) 888-5538 | www.functionaldevices.com

141

INTELLIGENT FIELD DEVICES

RIBTW2402B-BC

RIBTWX2401B-BC

RIBMNWD12-BC

INTELLIGENT FIELD DEVICES

RIBMNWX2401B-BC

RIBMW24B-44-BC

INTELLIGIENT FIELD DEVICES
Our Intelligent Field Devices can be hard wired and used instead of more expensive multioutput controllers when a few more control points are needed, and large controllers are too much for the job. They can also be used when control points are widely spread throughout the job site. These devices have been prepackaged to save the installer the time, trouble, and expense of buying separate components and assembling them on the job.
Product Features
· BACnet® and Modbus protocols · Analog input · Analog output · Binary output · Binary input · Thermistor inputs available · On-board current sensors available · Track mount and enclosed versions · NEMA 4X available · UL Listed

142

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

INTELLIGENT FIELD DEVICES

BACNET® DEVICES
POWER INPUT

CONTACT RATINGS

MODEL #

RELAY CONAC/DC AC TACTS RESISTIVE

MOTOR

PILOT DUTY

DRY

TRACK

CONTACT

ACCUMU- INTERNAL PRECON®

MOUNT /

BINARY ANALOG ANALOG LATOR CURRENT THERMISTOR OVERRIDE HOUSING

INPUT INPUT OUTPUT INPUT SENSOR INPUT SWITCH STYLE *

SPEC PAGE

RIBTW2401B-BC · 24

120 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

1

#

C

144

RIBTW2402B-BC · 24 208-277 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

1

#

C

145

RIBMNWX2401B-BC · 24

120 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

1

·

# MT212-6 146

RIBTWX2401B-BC · 24

120 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

1

·

#

D

147

RIBMNWX2402B-BC · 24 208-277 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

1

·

# MT212-6 148

RIBTWX2402B-BC · 24 208-277 1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

1

·

#

D

149

RIBMNW24B-BCAI · 24

1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

2

1

10k Type 2 or 3 # MT212-6 150

RIBTW24B-BCAI · 24

1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

2

1

10k Type 2 or 3 #

D

151

RIBTW24B-BCAO · 24

1 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

1

1

1

10k Type 2 or 3 #

D

152

RIBMNWD12-BCDI

24

12

MT212-6 153

RIBMNWD12-BC

24

12

2

RIBMW24B-44-BC · 24

4 SPDT 20 A @ 277Vac 2 HP @ 277Vac 1,110VA @ 277Vac

4

MT212-6 154 # MT4-6 155

OTHER BACNET® DEVICES: Fan Safety Alarm Circuit / General Purpose Logic Board (pg. 137) and UPS Kit (pg. 174)

MODBUS DEVICES
POWER INPUT

CONTACT RATINGS

MODEL #

RELAY AC/DC AC CONTACTS RESISTIVE

MOTOR

PILOT DUTY

PRECON®

DRY CONTACT ANALOG THERMISTOR OVERRIDE TRACK MOUNT /

BINARY INPUT INPUT

INPUT

SWITCH HOUSING STYLE *

SPEC PAGE

RIBMNW24B-MBAI · 24

1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac

2

1

10k Type 2

#

MT212-6

156

RIBTW24B-MBAI · 24

1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac

2

1

10k Type 2

#

D

157

= UL Listed - see data sheet for specific Listing
# = Coil Side Relay Override (requires unit to be powered)

= UL Component Recognized - see data sheet for specific Listing

* = See Housing Guide on page 201

^ = Track mount included

INTELLIGENT FIELD DEVICES

(800) 888-5538 | www.functionaldevices.com

143

INTELLIGENT FIELD DEVICE
RIBTW2401B-BC
BACnet MS/TP Network Relay Device, One Binary Output + Override, One Binary Input, 24 Vac/dc/120 Vac Power Input, NEMA 1 Housing

Dry Contact Binary Input
REF A(­) B(+) MSB LSB Baud Rate Relay Override

}
}

MSTP

0 1 1 2 3 4 5 6 7 8 9 10 11 12

24 Vac/dc Comm

MS/TP ADDRESS
Connect Jumper for EOL. Disconnect for no terminating resistor.

INTELLIGENT FIELD DEVICES

Wht/Yel Wht/Blk

Blu

Yel

Org

Neutral 120 Vac

N/C

C

N/O

SPECIFICATIONS

# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Communication Red LED: Relay Status Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No
Relay Override Switch: DIP Switch Control
Network Media: Twisted Pair 22-24AWG, shielded recommended
Terminations: Functional Devices product installed at both ends of the M S/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network.
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800,
115200 (DIP Switch Selectable)

Contact Ratings:

BACnet® Details:

20 Amp Resistive @ 277 Vac

· MS/TP Address & Baud Rate must be set

20 Amp Ballast @ 277 Vac

prior to power up via DIP switches.

16 Amp Electronic Ballast @ 277 Vac (N/O)

· Device ID will default to 277XXX where

10 Amp Tungsten @ 120 Vac (N/O)

XXX is the MS/TP Address.

1110 VA Pilot Duty @ 277 Vac

Examples:

770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

MS/TP Address - 004 Device ID - 277004
MS/TP Address - 121

Power Input Ratings:

Device ID - 277121

81 mA @ 24 Vdc

· Device ID can be changed via network

111 mA @ 24 Vac

command. Once changed, it will no longer

96 mA @ 120 Vac

default to 277XXX. (MS/TP Address & Device ID

must be unique.)

Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz

· This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input). · Device Instance changed via Object Identifier

Property of Device Object

Notes:

· PIC Statement available on website.

· When connecting 24 Vac to both the RIB(s) and a

half-wave device, damage to device can occur.

Option 1: Use separate transformers for each device.

Option 2: Add diode between devices, see Option 2

note below. ^^

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

All other combinations=9600 baud

BAUD RATE
9600 19200 38400 57600 76800 115200

DIP SWITCHES* RELAY STATE**

11

12

1

0

Auto

X

1

Override on

0

0

Override off

* 0 = Open ; 1 = Closed ** Device must be powered for override

· Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network.

RIBTW2401B-BC or RIBTW2402B-BC

Half-Wave Device

24 Vac

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

144

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

INTELLIGENT FIELD DEVICE
RIBTW2402B-BC
BACnet MS/TP Network Relay Device, One Binary Output + Override, One Binary Input, 24Vac/dc/208-277Vac Power Input, NEMA 1 Housing

}
}

MSTP

0 1 1 2 3 4 5 6 7 8 9 10 11 12

24 Vac/dc Comm

MS/TP ADDRESS
Connect Jumper for EOL. Disconnect for no terminating resistor.

Dry Contact Binary Input
REF A(­) B(+) MSB LSB Baud Rate Relay Override
INTELLIGENT FIELD DEVICES

Wht/Yel Wht/Brn

Blu

Yel

Org

Neutral 208-277 Vac N/C

C

N/O

SPECIFICATIONS

# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Communication Red LED: Relay Status Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No
Relay Override Switch: DIP Switch Control
Network Media: Twisted Pair 22-24AWG, shielded recommended
Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network.
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800,
115200 (DIP Switch Selectable)

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac 121 mA @ 208-277 Vac
Power Input: 24 Vac/dc ; 208-277 Vac ; 50/60 Hz
Notes: · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^

BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 Device ID - 277004
MS/TP Address - 121 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input). · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website.

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

All other combinations=9600 baud

BAUD RATE
9600 19200 38400 57600 76800 115200

24 Vac

DIP SWITCHES* RELAY STATE**

11

12

1

0

Auto

X

1

Override on

0

0

Override off

* 0 = Open ; 1 = Closed ** Device must be powered for override

· Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network.

RIBTW2401B-BC or RIBTW2402B-BC

Half-Wave Device

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

(800) 888-5538 | www.functionaldevices.com

145

INTELLIGENT FIELD DEVICE - RELAY / CURRENT SENSOR COMBO
RIBMNWX2401B-BC
BACnet MS/TP Network Relay Device, One Binary Output + Override, Two Binary Inputs (One Current Sensor Relay Load Sensing & One Dry Contact Binary Input), 24Vac/dc/120 Vac Power Input, 2.75"Track Mount

}

Dry Contact Binary Input

}
}

1 2 3 4 5 6 7 8 9 10 11 12

1 0
Relay Override
Baud Rate LSB
MSB

MS/TP ADDRESS

Connect Jumper for EOL. Disconnect for no terminating resistor.

MSTP

A(­)

B(+)

REF

Red LED=Relay Status Green LED=Network Communication
Pink LED=Current Sensor Status Pink LED=Binary Input Status

Low Voltage } Power Input

High Voltage } Power Input

C

Contacts

N/O

Internal

N/C

Current

Sensor

Neutral 120 Vac

24 Vac/dc Comm

INTELLIGENT FIELD DEVICES

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated
Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS, BTL Certified Gold Flash: No
Relay Override Switch: DIP Switch Control
Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable)

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

All other combinations=9600 baud

BAUD RATE
9600 19200 38400 57600 76800 115200

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz
Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 105 mA @ 120 Vac
Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps.

Notes: · Device can be powered by either 24 Vac/dc or 120 Vac, but not both. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^
BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 Device ID - 277004
MS/TP Address - 121 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website.

DIP SWITCHES* RELAY STATE**

11

12

1

0

Auto

X

1

Override on

0

0

Override off

* 0 = Open ; 1 = Closed ** Device must be powered for override
· Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network.

RIBMNWX2401B-BC or RIBTWX2401B-BC

Half-Wave Device

24 Vac

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

146

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

INTELLIGENT FIELD DEVICE - RELAY / CURRENT SENSOR COMBO
RIBTWX2401B-BC
BACnet MS/TP Network Relay Device, One Binary Output + Override, Two Binary Inputs (One Current Sensor Relay Load Sensing & One Dry Contact Digital Input), 24 Vac/dc/120 Vac Power Input, NEMA 1 Housing

}

Dry Contact Binary Input

}
}

1 2 3 4 5 6 7 8 9 10 11 12

1 0
Relay Override
Baud Rate LSB
MSB

MS/TP ADDRESS

Connect Jumper for EOL. Disconnect for no terminating resistor.

MSTP

A(­)

B(+)

REF

Red LED=Relay Status Green LED=Network Communication
Pink LED=Current Sensor Status Pink LED=Binary Input Status

Low Voltage } Power Input

High Voltage } Power Input

C

Contacts

N/O

Internal

N/C

Current

Sensor

Neutral 120 Vac

24 Vac/dc Comm

INTELLIGENT FIELD DEVICES

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated
Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS, BTL Certified Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No
Relay Override Switch: DIP Switch Control
Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable)

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

BAUD RATE
9600 19200 38400 57600 76800 115200

All other combinations=9600 baud

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz
Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 105 mA @ 120 Vac
Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps.

Notes: · Device can be powered by either 24 Vac/dc or 120 Vac, but not both. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2401B-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2401B-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2401B-BC-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^
BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 Device ID - 277004
MS/TP Address - 121 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website.

DIP SWITCHES*

11

12

1

0

X

1

0

0

RELAY STATE**
Auto Override on Override off

* 0 = Open ; 1 = Closed ** Device must be powered for override
· Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network.

RIBMNWX2401B-BC or RIBTWX2401B-BC

Half-Wave Device

24 Vac

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

(800) 888-5538 | www.functionaldevices.com

147

INTELLIGENT FIELD DEVICES

INTELLIGENT FIELD DEVICE - RELAY / CURRENT SENSOR COMBO

RIBMNWX2402B-BC
BACnet MS/TP Network Relay Device, One Binary Output + Override, Two Binary Inputs (One Current Sensor Relay
Load Sensing & One Dry Contact Digital Input), 24 Vac/dc or 208-277 Vac Power Input, 2.75"Track Mount

}

Dry Contact Binary Input

}
}

1 2 3 4 5 6 7 8 9 10 11 12

1 0
Relay Override
Baud Rate LSB
MSB

MS/TP ADDRESS

MSTP

Connect Jumper for EOL. Disconnect for no terminating resistor.

A(­)

B(+)

REF

Red LED=Relay Status Green LED=Network Communication
Pink LED=Current Sensor Status Pink LED=Binary Input Status

Low Voltage } Power Input

High Voltage } Power Input

C

Contacts

N/O

Internal

N/C

Current

Sensor

Neutral 208-277 Vac

24 Vac/dc Comm

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated
Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS, BTL Certified Gold Flash: No
Relay Override Switch: DIP Switch Control
Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable)

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

All other combinations=9600 baud

BAUD RATE
9600 19200 38400 57600 76800 115200

DIP SWITCHES* RELAY STATE**

11

12

1

0

Auto

X

1

Override on

0

0

Override off

* 0 = Open ; 1 = Closed ** Device must be powered for override

· Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network.

24 Vac

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input: 24 Vac/dc ; 208-277 Vac ; 50/60 Hz
Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 120 mA @ 208-277 Vac
Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps.

Notes: · Device can be powered by either 24 Vac/dc or 208-277 Vac, but not both. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^
BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 Device ID - 277004
MS/TP Address - 121 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website.

RIBMNWX2402B-BC or RIBTWX2402B-BC

Half-Wave Device

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

148

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

INTELLIGENT FIELD DEVICES

INTELLIGENT FIELD DEVICE - RELAY / CURRENT SENSOR COMBO
RIBTWX2402B-BC
BACnet MS/TP Network Relay Device, One Binary Output + Override, Two Binary Inputs (One Current Sensor Relay Load Sensing & One Dry Contact Binary Input), 24Vac/dc/208-277Vac Power Input, NEMA 1 Housing

}

Dry Contact Binary Input

}
}

1 2 3 4 5 6 7 8 9 10 11 12

1 0
Relay Override
Baud Rate LSB
MSB

MS/TP ADDRESS

MSTP

Connect Jumper for EOL. Disconnect for no terminating resistor.

A(­)

B(+)

REF

Red LED=Relay Status Green LED=Network Communication
Pink LED=Current Sensor Status Pink LED=Binary Input Status

Low Voltage } Power Input

High Voltage } Power Input

C

Contacts

N/O

Internal

N/C

Current

Sensor

Neutral 208-277 Vac

24 Vac/dc Comm

SPECIFICATIONS

# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated
Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS, BTL Certified Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No
Relay Override Switch: DIP Switch Control
Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable)

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input: 24 Vac/dc ; 208-277 Vac ; 50/60 Hz
Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 120 mA @ 208-277 Vac
Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps.

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

All other combinations=9600 baud

BAUD RATE
9600 19200 38400 57600 76800 115200

Notes: · Device can be powered by either 24 Vac/dc or 208-277 Vac, but not both. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2402B-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2402B-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2402B-BC-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^
BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 Device ID - 277004
MS/TP Address - 121 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website.

DIP SWITCHES* RELAY STATE**

11

12

1

0

Auto

X

1

Override on

0

0

Override off

* 0 = Open ; 1 = Closed ** Device must be powered for override

· Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network.

RIBMNWX2402B-BC or RIBTWX2402B-BC

Half-Wave Device

24 Vac

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

(800) 888-5538 | www.functionaldevices.com

149

INTELLIGENT FIELD DEVICES

INTELLIGENT FIELD DEVICE
RIBMNW24B-BCAI
BACnet MS/TP Network Relay Device with Binary Output Set Point, One Binary Output + Override, Two Binary Inputs, One Analog Input, 24 Vac/dc Power Input, 2.75"Track Mount

5V 10 V 1 2

A(­)

B(+)

REF

MS/TP ^See EOL Resistor jumper
1 0

^To select AI

OPEN

for Thermistor

AI Voltage

T2 or T3 input. Install jumper

Select

^# Switch

Connect Jumper for EOL.

Disconnect for no

terminating resistor

1 2 3 4 5 6 7 8 9 10 11 12

RELAY CONTROL

BAUD RATE

LSB MS/TP ADDRESS
MSB

Analog Type Jumpers OFF OFF Not de ned OFF ON T2 Thermistor ON OFF T3 Thermistor ON ON Analog IN 5V or 10V

AI A1 COM Therm. +5V

Analog In Close only one)

5V

SW1 Closed SW2 Open

10V

SW1 Open SW2 Closed

Thermistor T2 or T3 input, use 5V
selection

24 Vac/dv}
Comm N/C

Green LED - Network Status Red LED - Relay Status Pink LED - B1 1 Status Pink LED - B1 2 Status BI 1 COM BI 1 BI 2 COM BI 2

Relay

N/O

Contacts

C

Code Version 1.5

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated BI1 Status: Pink LED On = Activated BI2 Status: Pink LED On = Activated Dimensions: 5.68"H x 2.75"W x 1.25"D1/1.75"D2
Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS, BTL Certified Gold Flash: No
Relay Override Switch: DIP Switch Control (See Bulletin B1243)
Network Media: Twisted Pair 22-24AWG, shielded recommended
Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network.
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200
(DIP Switch Selectable - See Bulletin B1243)

Sensor 0-5Vdc, 0-10Vdc or T2/T3 Thermistor

Set Point Function
for App. Version 1.5 or higher
BCAI

BI1 BI2

BO1

AI1 Logic

Set Point Differential

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Notes: · For all versions, raw analog default settings are 0 and 1023 (real), respectively. Units default to 95 (no units).
For Set Point Function settings, See Bulletin B1243 · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, (See Bulletin B1243 for diagram)

Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac
· PIC Statement available on website.

BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Dry contact binary input), AI 1 (Analog input), AV1 (Set Point), AV2 (Differential), BV1 (Function Enable), BV2 (Function Mode), BV3 (Function Status) · Device Instance changed via Object Identifier Property of Device Object
Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included.

Network

· For both T2 and T3, MIN_PRES_VAL must be set to -36 (real value) and MAX_PRES_VAL must be set to 66.3 (real value) for Celcius. For Fahrenheit, MIN_PRES_VAL must be set to -32.8 (real value) and MAX_PRES_VAL must be set to 151.34 (real value). · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps

Set Point Function must be enabled via the Network for logic to execute. Once configured, the function will continue to operate
even if communication is lost (see Bulletin B1243 for setup).

150

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

INTELLIGENT FIELD DEVICES

INTELLIGENT FIELD DEVICE
RIBTW24B-BCAI
BACnet MS/TP Network Relay Device with Binary Output Set Point, One Binary Output + Override, Two Binary Inputs, One Analog Input, 24 Vac/dc Power Input, NEMA 1 Housing

5V 10 V 1 2

A(­)

B(+)

REF

MS/TP ^See EOL Resistor jumper
1 0

^To select AI

OPEN
AI Voltage Select ^# Switch

for Thermistor T2 or T3 input. Install jumper

Connect Jumper for EOL.

Disconnect for no

terminating resistor

1 2 3 4 5 6 7 8 9 10 11 12

RELAY CONTROL

BAUD RATE

LSB MS/TP ADDRESS
MSB

Analog Type Jumpers OFF OFF Not de ned OFF ON T2 Thermistor ON OFF T3 Thermistor ON ON Analog IN 5V or 10V

AI A1 COM Therm. +5V

Analog In Close only one)

5V SW1 Closed SW2 Open

10V

SW1 Open SW2 Closed

Thermistor T2 or T3 input, use 5V
selection

24 Vac/dv}
Comm N/C

Green LED - Network Status Red LED - Relay Status Pink LED - B1 1 Status Pink LED - B1 2 Status BI 1 COM BI 1 BI 2 COM BI 2

N/O

Relay Contacts

C

Code Version 1.5

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated BI1 Status: Pink LED On = Activated BI2 Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple
Housing Detail: See Housing D in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS
Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X
Gold Flash: No Relay Override Switch: DIP Switch Control (See Bulletin B1243)

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac
· PIC Statement available on website.

Network Media: Twisted Pair 22-24AWG, shielded recommended
Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use
120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable - See Bulletin B1243)

Sensor 0-5Vdc, 0-10Vdc or T2/T3 Thermistor

Set Point Function
for App. Version 1.5 or higher
BCAI

BI1 BI2

BO1

AI1 Logic

Set Point Differential

Network

Notes: · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24B-BCAI-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTW24B-BCAI-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTW24B-BCAI-N4-GY) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. Units default to 95 (no units).
For Set Point Function settings, See Bulletin B1243 · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, (See Bulletin B1243 for diagram)
BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Dry contact binary input), AI 1 (Analog input), AV1 (Set Point), AV2 (Differential), BV1 (Function Enable), BV2 (Function Mode), BV3 (Function Status) · Device Instance changed via Object Identifier Property of Device Object
Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included.
· For both T2 and T3, MIN_PRES_VAL must be set to -36 (real value) and MAX_PRES_VAL must be set to 66.3 (real value) for Celcius. For Fahrenheit, MIN_PRES_VAL must be set to -32.8 (real value) and MAX_PRES_VAL must be set to 151.34 (real value). · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps

Set Point Function must be enabled via the Network for logic to execute. Once configured, the function will continue to operate
even if communication is lost (see Bulletin B1243 for setup).

(800) 888-5538 | www.functionaldevices.com

151

INTELLIGENT FIELD DEVICES

INTELLIGENT FIELD DEVICE
RIBTW24B-BCAO
BACnet MS/TP Network Relay Device, One Binary Output + Override, One Binary Input, One Analog Output, One Analog Input, 24Vac/dc Power Input, NEMA 1 Housing

A(­)

B(+)

REF LSB

AI COM AI

Therm. +5V

24 Vac/dc Power

MS/TP

Thermistor Select

RELAY CONTROL

10 V 5 V 1 2

1 2 3 4 5 6 7 8 9 10 11 12 OPEN

MSB

MS/TP ADDRESS

BAUD RATE

AI Voltage Select Switch

J1: Jumper for EOL resistor

Green LED=Network Status

Red LED=Relay Status

J5: Install for 0-10 V

J2 J3

Analog In

ON ON

T3 Thermistor ON OFF

T2 Thermistor OFF ON

Not de ned OFF OFF

(­) (+)

Dry Contact BI COM

(­)

Binary Input

B I

(+)

N/C N/O
C

Pink LED=BI Status
Relay Contacts

}
Analog Output 4-20 mA
Analog Output 0-5 Vdc
0-10 Vdc

Shown With Cover

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Relay Activated
Binary Input Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple
Housing Detail: See Housing D in housing guide for dimensions Origin:: Made of US and non-US parts
Approvals: UL Listed, UL916, C-UL, RoHS, BTL Certified Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved,
UL Accepted for Use in Plenum, Gold Flash: No Relay Override: DIP Switch Control
Network Media: Twisted Pair 22-24AWG, shielded recommended
Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network.
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800,
115200 (DIP Switch Selectable)

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Magnetic Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input Ratings: 176 mA @ 24 Vac 150 mA @ 24 Vdc

Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included.
· -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps
BACnet® Details:
· This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), AI 1 (Analog input), AO 1 (Analog output)

Notes:

· PIC Statement available on website.

· Use a separate 24 Vac transformer, or an isolated 24 Vdc power supply to power-up this product.

· Addressing Specifications: Bulletin B2028 available on website.

· Complete Installation Instructions:

Bulletin B1756 available on website.

· When connecting 24 Vac to both the RIB(s)

and a half-wave device, damage to device

can occur. Option 1: Use separate

transformers for each device. Option 2:

Add diode between devices, see Option 2

note below. ^^

Analog Output Voltage (0-5 Vdc; 0-10 Vdc) Analog Output Current (4-20 mA)

ANALOG OUTPUT ACCURACY AS A FUNCTION OF OUTPUT SPAN (USING STANDARD CONDITIONS *)

Span 20% - 100%

Span 10% - 100%

Span 0% - 100%

+/- 2% error

+/- 5% error

+/- 11% error

+/- 2% error

+/- 3% error

+/- 12% error

* Standard Conditions: Power Supply Input: 22 Vac/dc to 28 Vac/dc ; Loop Resistance (Analog Output 4-20 mA Loop): 530 Ohms max. Load Resistance [Analog Output Voltage (0-5 Vdc, 0-10 Vdc)]: 10 K Ohms min. ; Ambient Temperature: -30 to 140° F

0-5Vdc or 0-10 Vdc Temperature,
Humidity, Pressure Transducer

AI AI Com

Analog 10K Input

RIBTW24B-BCAO

Half-Wave Device

24 Vac

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

152

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

INTELLIGENT FIELD DEVICE
RIBMNWD12-BCDI
BACnet MS/TP Network Input Device, Twelve Binary Inputs (Voltage or Dry Contacts), 2.75"Track Mount

}
} } } } } } }

24 Vac/dc

MSTP

BI 1

BI 2

BI 3

BI 4

BI 5

BI 6

A(­) B(+) REF +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM

Connect Jumper for terminating resistor. Disconnect for no terminating resistor.

Pink LEDs = Digital Input Status
Connect Jumper for Dry Contact Operation. Disconnect for voltage input operation.

Green LED = Network Communication Red LED = Power

} } } } } }
Not Used Baud Rate LSB
MSB

1 2 3 4 5 6 7 8 9 10 MS/TP ADDRESS

COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V

BI 12

BI 11

BI 10

BI 9

BI 8

BI 7

SPECIFICATIONS

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Green LED: Network Communication Red LED: ON = Power Present Dimensions: 6.00"H x 2.75"W x 1.25"D1/1.75"D2 Origin: See Housing H in housing guide for dimensions Track Mount: Made of US and non-US parts Approvals: MT212-6 Mounting Track Provided CE, RoHS, BTL Certified Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Band Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable)

Power Input Ratings: 41 mA @ 24 Vdc 53 mA @ 24 Vac

Binary Input Ratings: Dry Contact: 3 mA @ 30 Vdc max. Voltage Input: 12 mA @ 25 Vac/dc max.

BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:

MS/TP Address - 004 Device ID - 277004

MS/TP Address - 121 Device ID - 277121

· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Device Instance changed via Object Identifier Property of Device Object · Full wave rectified

· PIC Statement available on website.

· Objects included in device are:

BI 1 (Binary input)

BI 7 (Binary input)

BI 2 (Binary input)

BI 8 (Binary input)

BI 3 (Binary input)

BI 9 (Binary input)

BI 4 (Binary input)

BI 10 (Binary input)

BI 5 (Binary input)

BI 11 (Binary input)

BI 6 (Binary input)

BI 12 (Binary input)

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

BAUD RATE
9600 19200 38400 57600 76800 115200

* 0 = Open ; 1 = Closed All other combinations=9600 baud

Example of Dry Contact Input Operation

Example of Voltage Input Operation

Dry
Contact N/C
+V Vin COM

Voltage Source + ­
+V Vin COM

Jumper Connected

Jumper Disconnected

INTELLIGENT FIELD DEVICES

(800) 888-5538 | www.functionaldevices.com

153

INTELLIGENT FIELD DEVICE

RIBMNWD12-BC
BACnet MS/TP Network Input Device, Twelve Binary Inputs
(Voltage or Dry Contacts), Accumulators, 2.75"Track Mount

MSTP BI 1/ACC1 BI 2/ACC2

BI 3

BI 4

BI 5

BI 6

24 Vac/dc

A(­) B(+) REF +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM

}
} } } } } } }

Connect Jumper for EOL. Disconnect for no terminating resistor.

Pink LEDs = Digital Input Status
Connect Jumper for Dry Contact Operation. Disconnect for voltage input operation.

Green LED = Network Communication Red LED = Power

} } } } } }
Not Used Baud Rate LSB
MSB

1 2 3 4 5 6 7 8 9 10 MS/TP ADDRESS

COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V

BI 12

BI 11

BI 10

BI 9

BI 8

BI 7

TWO (ACCUMULATOR) INPUTS CAN BE USED FOR POWER
MONITORING OR OTHER PULSE COUNTING APPLICATION.

SPECIFICATIONS

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Green LED: Network Communication Red LED: ON = Power Present Dimensions 6.00"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, RoHS, BTL Certified
Network Media: Twisted Pair 22-24AWG, shielded recommended
Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network.
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800,
115200 (DIP Switch Selectable)

Power Input Ratings: 41 mA @ 24 Vdc 53 mA @ 24 Vac
Max. Accumulator Frequency: 50 Hz
BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Device Instance changed via Object Identifier Property of Device Object
· PIC Statement available on website.

Binary Input Ratings: Dry Contact: 3 mA @ 30 Vdc max. Voltage Input: 12 mA @ 25 Vac/dc max.

· Objects included in device are:

} BI 1 (Binary input)

Use Same

ACC 1 (Accumulator) Physical Input

} BI 2 (Binary input)

Use Same

ACC 2 (Accumulator) Physical Input

BI 3 (Binary input)

BI 4 (Binary input)

BI 5 (Binary input)

BI 6 (Binary input)

BI 7 (Binary input)

BI 8 (Binary input)

BI 9 (Binary input)

BI 10 (Binary input)

BI 11 (Binary input)

BI 12 (Binary input)

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

BAUD RATE
9600 19200 38400 57600 76800 115200

* 0 = Open ; 1 = Closed All other combinations=9600 baud

Example of Dry Contact Input Operation

Example of Voltage Input Operation

Dry
Contact N/C
+V Vin COM

Voltage Source + ­
+V Vin COM

Jumper Connected

Jumper Disconnected

INTELLIGENT FIELD DEVICES

154

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

BO1 C BO1 N/O BO1 N/C BO2 C BO2 N/O BO2 N/C

INTELLIGENT FIELD DEVICE
RIBMW24B-44-BC
BACnet MS/TP Network Relay Device, Four Binary Outputs + Override, Four Binary Inputs, 24 Vac/dc Power Input, 4.00"Track Mount

REF

B(+)

A(­)

MSTP

1 0
Baud Rate LSB
MSB

DIP 1 1 2 3 4 5 6 7 8 9 10

DIP 2 12345678

MS/TP ADDRESS BO1 BO2

RELAY OVERRIDE

Connect Jumper

Red LEDs

BO3 BO4

for terminating resistor. Disconnect for no terminating resistor.

Network Status Green LED

Pink LEDs

BI1

BI2

BI3

BI4

Power Input

Relay 1 Contacts Relay 2 Contacts

Relay 3 Contacts Relay 4 Contacts

BO3 N/C BO3 N/O BO3 C BO4 N/C BO4 N/O BO4 C

BI1 COM BI1 BI2 COM BI2 BI3 COM BI3 BI4 COM BI4

24 Vac/dc Comm

SPECIFICATIONS
# Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated
Binary Input Status: Pink LED On = Activated Dimensions: 6.00"H x 4.00"W x 0.88"D1/1.38"D2
Housing Detail: See Housing H in housing guide for dimensions Origin:: Made of US and non-US parts
Track Mount: MT4-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS, BTL Certified Gold Flash: No
Relay Override Switch: DIP Switch Control
Network Media: Twisted Pair 22-24AWG, shielded recommended
Terminations: Functional Devices product installed at both ends of the MS/TP network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the MS/TP network.
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800,
115200 (Dip Switch Selectable)

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input Ratings: 24 Vac : 400 mA 24 Vdc : 190 mA

BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples:
MS/TP Address - 004 Device ID - 277004
MS/TP Address - 121 Device ID - 277121
· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique) · This model utilizes: BO1, BO2, BO3, BO4, (Relay outputs), BI1, BI2, BI3, BI4 (Dry contact inputs) · Device Instance changed via Object Identifier Property of Device Object · Each unit is 1/8 unit load
· PIC Statement available on website.

DIP 1

DIP 2

DIP Switches

1-7

8

9

10

0

0

0

0

0

1

See Bulletin

B1082 for

0

1

0

full MS/TP

0

1

1

Addressing

1

0

0

1

0

1

All other combinations=9600 baud

Baud Rate
9600 19200 38400 57600 76800 115200

· Dry contact digital input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network.

Relay BO1 BO2 BO3 BO4

Relay State**
Auto ON OFF Auto ON OFF Auto ON OFF Auto ON
OFF

1

2

1

X

X

X

0

X

X

1

X

X

X

0

X

X

X

X

X

X

X

X

X

X

X

X

DIP Switches*

3

4

5

6

7

8

X

X

0

X

X

X

X

X

1

X

X

X

X

X

0

X

X

X

X

X

X

0

X

X

X

X

X

1

X

X

X

X

X

0

X

X

1

X

X

X

0

X

X

X

X

X

1

X

0

X

X

X

0

X

X

1

X

X

X

0

X

X

X

X

X

1

X

0

X

X

X

0

* 0 = Open ; 1 = Closed

** Device must be powered for override

INTELLIGENT FIELD DEVICES

(800) 888-5538 | www.functionaldevices.com

155

INTELLIGENT FIELD DEVICES

INTELLIGENT FIELD DEVICE

RIBMNW24B-MBAI
MODbus RTU Network Relay Device, One Binary Output + Override, Two
Binary Inputs, One Analog Input, 24 Vac/dc Power Input, 2.75"Track Mount

Green LED=Network Status Red LED=Relay Status Pink LED=BI 1 Status Pink LED=BI 2 Status BI 1 COM BI 1 BI 2 COM BI 2

5 V 10 V 1 2

A(­)

B(+)

REF

OPEN

^ To select AI
for Thermistor

Standard RS-485 Modbus® RTU Protocol.

AI Voltage Select Switch

T2 input, install jumper.

EOL termination resistor jumper.

1 0

Connect jumper for terminating resistor.

Relay Control

1 2 3 4 5 6 7 8 9 10 11 12

Baud Rate
LSB
Modbus® RTU
ADDRESS
MSB

Both jumpers installed from factory. Remove
left jumper from Thermistor-Input-Select^
for T2 Thermistor Input, otherwise leave both
on for 5V or 10V Analog In. Connect Analog
In between AI and AI common. Connect
Thermistor between AI and Thermistor +5V.

O O Not de ned O On T2 Thermistor On On Analog In 5V or 10V

Type Analog

AI AI COM Therm. +5V

Analog In (Close only one)
SW1 Closed 5 V
SW2 Open
10 V SW1 Open SW2 Closed
Thermistor T2 input, use 5 V selection

Contacts

Relay

N/C }

24 Vac/dc Comm

N/O

C

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated
Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.25 x 2.75 x 1.75 Origin: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Gold Flash: No
Relay Override Switch: DIP Switch Control

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac

Network Media: Twisted Pair 22-24AWG, shielded recommended, EIA/TIA-485 (standard RS485)
Terminations: Functional Devices product installed at both ends of the standard RS485 Modbus® RTU network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the Modbus® network.
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600 (DIP Switch Selectable)

Notes: · Modbus®Address & Baud Rate must be set prior to power up via DIP switches. · This model utilizes: Physical coil 1 (Relay output) Physical binary input 1 (Dry contact binary input) Physical binary input 2 (Dry contact binary input) Physical input register AI 1 (Analog input) · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor not included. (Range -39 to 187°F) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below.^^ · Address and Baud Rate Settings on Bulletin B1676 available on website.
Modbus® is a registered trademark of Schneider Electric licensed to the Modbus Organization, Inc.

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

BAUD RATE
9600 19200 38400 57600

All other combinations=9600 baud

DIP SWITCHES* RELAY STATE**

11

12

1

0

Auto

X

1

Override on

0

0

Override off

* 0 = Open ; 1 = Closed ** Device must be powered for override

· Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to feed back to the network.

RIBMNW24B-MBAI or RIBTW24B-MBAI

Half-Wave Device

24 Vac

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

156

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

INTELLIGENT FIELD DEVICES

INTELLIGENT FIELD DEVICE

RIBTW24B-MBAI
MODbus RTU Network Relay Device, One Binary Output + Override, Two Binary Inputs,
One Analog Input, 24 Vac/dc Power Input, NEMA 1 Housing

Green LED=Network Status Red LED=Relay Status Pink LED=BI 1 Status Pink LED=BI 2 Status BI 1 COM BI 1 BI 2 COM BI 2

5 V 10 V 1 2

A(­)

B(+)

REF

OPEN

^ To select AI
for Thermistor

Standard RS-485 Modbus® RTU Protocol.

AI Voltage Select Switch

T2 input, install jumper.

EOL termination resistor jumper.

1 0

Connect jumper for terminating resistor.

Relay Control

1 2 3 4 5 6 7 8 9 10 11 12

Baud Rate
LSB
Modbus® RTU
ADDRESS
MSB

Both jumpers installed from factory. Remove
left jumper from Thermistor-Input-Select^
for T2 Thermistor Input, otherwise leave both
on for 5V or 10V Analog In. Connect Analog
In between AI and AI common. Connect
Thermistor between AI and Thermistor +5V.

O O Not de ned O On T2 Thermistor On On Analog In 5V or 10V

Type Analog

AI AI COM Therm. +5V

Analog In (Close only one)
SW1 Closed 5 V
SW2 Open
10 V SW1 Open SW2 Closed
Thermistor T2 input, use 5 V selection

Contacts

Relay

N/C }

24 Vac/dc Comm

N/O

C

SPECIFICATIONS
# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms
Network Communication: Green LED Relay Status: Red LED On = Activated
Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions Origin:: Made of US and non-US parts Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No
Relay Override Switch: DIP Switch Control

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac

Network Media: Twisted Pair 22-24AWG, shielded recommended, EIA/TIA-485 (standard RS485)
Terminations: Functional Devices product installed at both ends of the standard RS485 Modbus® RTU network ­ Use 120  end of line resistors. All other cases ­ Follow instructions from the device installed at the end of the Modbus® network.
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600 (DIP Switch Selectable)

Notes: · Modbus®Address & Baud Rate must be set prior to power up via DIP switches. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24B-MBAI-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTW24B-MBAI-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTW24B-MBAI-N4-GY) · This model utilizes: Physical coil 1 (Relay output) Physical binary input 1 (Dry contact binary input) Physical binary input 2 (Dry contact binary input) Physical input register AI 1 (Analog input) · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor not included. (Range -39 to 187°F) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below.^^ · Address and Baud Rate Settings on Bulletin B1676 available on website.
Modbus® is a registered trademark of Schneider Electric licensed to the Modbus Organization, Inc.

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

BAUD RATE
9600 19200 38400 57600

All other combinations=9600 baud

DIP SWITCHES* RELAY STATE**

11

12

1

0

Auto

X

1

Override on

0

0

Override off

* 0 = Open ; 1 = Closed ** Device must be powered for override

· Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to feed back to the network.

RIBMNW24B-MBAI or RIBTW24B-MBAI

Half-Wave Device

24 Vac

24 Vac/dc Comm

24 Vac Comm

IN4004
^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).

(800) 888-5538 | www.functionaldevices.com

157

NOTES

INTELLIGENT FIELD DEVICES

158

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER METER KIT
Introducing our new BACnet® Compatible Power Meter Kit. This Power Meter Kit includes the BACnet® Compatible Power Meter circuit board, which will collect and send all the data points to the BAS controller. Also included in this Kit is the fuse holder, fuses, and disconnect switch. Everything is prepackaged and prewired in an 18-gauge steel enclosure. This Power Meter Kit is compatible with single or three-phase electrical systems. This Kit is a great solution for revenue-grade power metering applications.

· Revenue Grade Power Meter · Power Meter input power: 120-277 Vac · Made in the U.S.A

· Includes 16 Amp rated Disconnect Switch * · Includes Fuse holder with three 2 Amp rated fuses ^
Dimensions: 8.3" H x 7.7" W (9.2" W with switch) x 3.9" D

BACnet Power Meter Kit
· Power meter circuit board · Disconnect switch · Fuse holder · Fuses
RIBPM413-BC-KIT

POWER MONITORING

A B C N
A B C

REF

NOT USED

B(+)

REMOTE STATUS

NOT USED

LED

LED

A(-)

*
^

#

LINE 1

CT L3

LINE 2

CT L2

LINE 3

CT L1

NEUTRAL

Current Transformers
See page 163 for available models

FOR MORE PRODUCT INFORMATION, SEE PAGE 160.

(800) 888-5538 | www.functionaldevices.com

159

PPPOOOWWWEEERRRMMMEEETTTEEERRRKKIITT-- BBAACCNNEETT®® CCOOMMPPAATTIIBBLLEE
RIBPM413-BC-KIT
PPower Meter Kit, 120-277 Vac, 3-Phase, Disconnect Switch, Fuses and Fuse Holder

C BA ***

REF

Not Used

B(+) REMOTE STATUS Not Used

A(-)

LED

LED

CT L3 CT L2 CT L1

LINE 1 LINE 2 LINE 3 NEUT

NC BA ** *

SPECIFICATIONS
Power Meter - RIBPM413-BC: *Power Input Rating: 120-277 Vac, Powered from Line 1 to Neutral, < 2 VA
Headers: Pluggable screw terminals, accept 12 to 28 AWG wire Dimensions: 2.75" H x 4.5"W x 0.85" D with headers installed
Origin: Made of US and non-US parts Frequency: 50/60 Hz Operating Temperature: -20 to 70°C, -4 to 158°F
Humidity: 5 to 95% (noncondensing) Altitude: Up to 2,000 m
Remote LED: Green = Rx Amber = Tx
Status LED: See Bulletin B2646 Terminal Torque: 4.43 in-lbs
Approvals: CE, UL Listed, UL 61010-1 and UL 61010-2-30, C-UL, RoHS, FCC Part 15 Class B
Network Media: 18-22 AWG, 2-Core, shielded twisted pair Network Termination: For End of Line (EOL) device, use 120  Resistor.
See Bulletin B2646 for details Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200; Set via BACnet®
Fuse Holder: Type: Class CC Rated Current: 30 Amps Rated Voltage: 600 Vac Interrupt Rating: 200kA Max Ambient Temp: 125°C, 257°F Wire Gauge: 10-14 AWG Terminal Torque: 20 in-lbs Approvals: UL Listed, CSA Certified, RoHS, CE
Disconnect Switch*: Rated Current: 16 Amps Rated Voltage: 600 Vac Interrupt Rating: 10kA Ambient Temperature: -25 to 50°C, -13 to 122°F
Wire Gauge: 10-14 AWG Mechanical Life: 1 million cycles Terminal Torque: 7 in-lbs
Approvals: UL508, IEC 60947-3, EN 60947-3 and CSA 22.2, CE, RoHS

Enclosure: Construction: 18 Gauge Steel
Cover Type: Screw Down Cover Dimensions: 8.3" H x 7.7"W (9.2"W with switch) x 3.9" D
Rating: NEMA 1 Approvals: UL Listed, CE, RoHS
Fuses**: Type: Class CC, Fast-acting Rated Current: 2 Amps Rated Voltage: 600 Vac Interrupt Rating: 200kA Approvals: CSA Certified, CE, RoHS
Metered Circuit: Voltage Range: 120 - 277 Vac L-N (CAT III); 1P 2/3W, 3P 4W Voltage Overload: 1.1 x Voltage Range Voltage Burden: < 0.1 VA @ 277 Vac Frequency Range: 45 - 65 Hz Current Transformer: 333 mV Output (sold separately) Current Overload: 1.2 x CT Output Power Overload: 1.2 x Voltage Range x CT Output
Measurement Accuracy: Voltage: 0.5%, < 0.2% typical from 80-120% Current: 0.5%, < 0.2% typical from 10-120% Power: 0.5%, < 0.2% typical from 10-120%
Power Factor: 0.5% between 0.5 and 1.0
BACnet® Details: · Device ID Default: 277050 · MAC Address Default: 50 · Baud Rate Default: 38400 · CT-Ratings (AV-8005) must be updated with the current rating of the CTs used with the device. · See Bulletin B2646 for further details · PIC Statement available on website.
https://www.functionaldevices.com/downloads/pics/BACnet-PM413_PICS.pdf
Notes: · See Bulletin B2818 for installation instructions · Bi-directional for NET metering · For compatible Current Transformers, see our CT Series*** * Neutral connection required for Input Power

POWER MONITORING

160

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

PPOOWWEERR MMEETTEERR - BACNET® COMPATIBLE
RIBPM413-BC
Power Meter, 120-277 Vac, 3-Phase, 2.75" Track Mount

C BA

REF

Not Used

B(+) REMOTE STATUS Not Used

A(-)

LED

LED

CT L3 CT L2 CT L1

LINE 1 LINE 2 LINE 3 NEUT

NC BA

SPECIFICATIONS
*Power Input Rating: Powered from Line 1 to Neutral, 120-277 Vac, < 2 VA
Headers: Pluggable screw terminal, accepts up to 12 AWG stranded copper wire
Frequency: 50/60 Hz Operating Temperature: -4 to 158 °F
Storage Temperature: -40 to 185 °F Humidity: 5 to 95% (noncondensing) Altitude: Up to 2,000 m
Remote LED: Green = Rx Amber = Tx
Status LED: See Bulletin B2646 Dimensions: 2.75" H x 4.5"W x 0.85" D with headers installed Housing Detail: See Housing H in housing guide for dimensions
Origin: Made of US and non-US parts Track Mount: MT212-4 mounting track provided
Approvals: CE, UL Listed, UL 61010-1 and UL 61010-2-30, C-UL, RoHS, FCC Part 15 Class B
Network Media: 18-22 AWG, 2-Core, shielded twisted pair Network Termination: For End of Line (EOL) device, use
120  Resistor. See Bulletin B2646 for details Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200; set via BACnet®

Metered Circuit: Voltage Range: 120-277 Vac L-N (CAT III);
1P 2/3W, 3P 4W Voltage Overload: 1.1 x Voltage Range
Voltage Burden: < 0.1 VA @ 277 Vac Frequency Range: 45 - 65 Hz Current Transformer: 333 mV Output Current Overload: 1.2 x CT Output
Power Overload: 1.2 x Voltage Range x CT Output
Measurement Accuracy: Voltage: 0.5%, < 0.2% typical from 80-120% Current: 0.5%, < 0.2% typical from 10-120% Power: 0.5%, < 0.2 % typical from 10-120%
Power Factor: 0.5% between 0.5 and 1.0
BACnet® Details: · Device ID Default: 277050 · MAC Address Default: 50 · Baud Rate Default: 38400 · CT-Ratings (AV-8005) must be updated with the current rating of the CTs used with the device. · See Bulletin B2646 for further details · PIC Statement available on website.
https://www.functionaldevices.com/downloads/pics/BACnet-PM413_PICS.pdf
Notes: · See Bulletin B2646 for installation instructions · Bi-directional for NET metering * Neutral connection required for Input Power

POWER MONITORING

(800) 888-5538 | www.functionaldevices.com

161

PPOOWWEERR MMEETTEERR - BACNET® COMPATIBLE
RIBTPM413-BC
Power Meter, 120-277 Vac, 3-Phase, NEMA 1 Housing

C BA

REF

Not Used

B(+) REMOTE STATUS Not Used

A(-)

LED

LED

CT L3 CT L2 CT L1

LINE 1 LINE 2 LINE 3 NEUT

NC BA

SPECIFICATIONS
*Power Input Rating: Powered from Line 1 to Neutral, 120-277 Vac, < 2 VA
Headers: Pluggable screw terminal, accepts up to 12 AWG stranded copper wire
Frequency: 50/60 Hz Operating Temperature: -4 to 158 °F
Storage Temperature: -40 to 185 °F Humidity: 5 to 95% (noncondensing) Altitude: Up to 2,000 m
Remote LED: Green = Rx Amber = Tx
Status LED: See Bulletin B2646 Dimensions: 4.28"H x 7.00"W x 2.00"D with 0.75" NPT nipple Housing Detail: See Housing D in housing guide for dimensions
Origin:: Made of US and non-US parts Track Mount: MT212-6 mounting track provided
Approvals: CE, UL Listed, UL 61010-1 and UL 61010-2-30, C-UL, RoHS, FCC Part 15 Class B (circuit board)
Housing Ratings: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X
Network Media: 18-22 AWG, 2-Core, shielded twisted pair For End of Line (EOL) device, use
Network Termination: 120  Resistor. See Bulletin B2646 for details
Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600,
76800, 115200; set via BACnet®

Metered Circuit: Voltage Range: 120-277 Vac L-N (CAT III);
1P 2/3W, 3P 4W Voltage Overload: 1.1 x Voltage Range
Voltage Burden: < 0.1 VA @ 277 Vac Frequency Range: 45 - 65 Hz Current Transformer: 333 mV Output Current Overload: 1.2 x CT Output
Power Overload: 1.2 x Voltage Range x CT Output
Measurement Accuracy: Voltage: 0.5%, < 0.2% typical from 80-120% Current: 0.5%, < 0.2% typical from 10-120% Power: 0.5%, < 0.2 % typical from 10-120%
Power Factor: 0.5% between 0.5 and 1.0
BACnet® Details: · Device ID Default: 277050 · MAC Address Default: 50 · Baud Rate Default: 38400 · CT-Ratings (AV-8005) must be updated with the current rating of the CTs used with the device. · See Bulletin B2646 for further details · PIC Statement available on website.
https://www.functionaldevices.com/downloads/pics/BACnet-PM413_PICS.pdf
Notes: · See Bulletin B2646 for installation instructions · Bi-directional for NET metering · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTPM413-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTPM413-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTPM413-BC-N4-GY) * Neutral connection required for Input Power

POWER MONITORING

162

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RIB CURRENT TRANSFORMERS PPOOWWEERRMMEETTEERR KIT- BA®CNET® COMPATIBLE

POWER MONITORING

CT-05A0-333

CT-100A2-333

CT-400A4-333

ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV

CT-100A1-333

CT-100A4-333

CT-200A4-333

CT-025A1-333

CT-050A1-333

CTS-100A55-333

MOD1-07-33MV

FDI MODEL
CT-05A0-333 CT-025A1-333 CT-050A1-333 CT-100A1-333 CT-100A2-333 CT-100A4-333 CT-200A4-333 CT-400A4-333 CT-600A4-333 CTS-05A20-333 CTS-30A20-333 CTS-60A35-333 CTS-100A55-333 ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV

PRIMARY INPUT (A) SECONDARY OUTPUT (V)

RATIO

5 25 50 100 100 100 200 400 600 5 30 60 100 4,000 6,000 8,000 10,000

0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.333 0.07 0.07 0.07 0.07

5A/0.333V 25A/0.333V 50A/0.333V 100A/0.333V 100A/0.333V 100A/0.333V 200A/0.333V 400A/0.333V 600A/0.333V 5A/0.333V 30A/0.333V 60A/0.333V 100A/0.333V 4,000/70mV 6,000/70mV 8,000/70mV 10,000/70mV

ACCURACY (%) 0.3 0.8 0.5 0.5 0.75 0.5 0.5 0.5 0.5 0.2 0.2 0.2 0.2 0.75 0.75 0.75 0.75

CORE TYPE
Split Split Split Split Split Split Split Split Split Solid Solid Solid Solid Rope Rope Rope Rope

WINDOW SIZE
.47" x .45" .72" x .62" .72" x .62" .72" x .62" 1.0" x 1.4" 1.3" x 1.7" 1.3" x 1.7" 1.3" x 1.7" 1.3" x 1.7" .2" diameter .2" diameter .35 diameter .55 diameter 5.0" diameter 7.6" diameter 11.5" diameter 15.3" diameter

"MOD" & "ROPE" Series
The MOD series of devices are optional modules that connect to the output of the Rogowski Coil CTs (ROPE units) and convert the output to the 0.333 V analog scale for use in other Power Monitoring systems. The MOD series has options for one, two, or three-phase power feeds. The MOD series devices are DIN rail-mountable, are ETL approved, and require 12 Vdc for input voltage.

FDI MODEL
MOD1-07-33MV MOD2-07-33MV MOD3-07-33MV ROPE16-040A-07MV ROPE24-060A-07MV ROPE36-080A-07MV ROPE48-100A-07MV

PRIINPUT (A)
0.07 0.07 0.07 4,000 6,000 8,000 10,000

SECONDARY OUTPUT (V)
0.333 0.333 0.333 0.07 0.07 0.07 0.07

ACCURACY (%)
0.50 0.50 0.50 0.75 0.75 0.75 0.75

USED WITH
Any "ROPE" CT Any "ROPE" CT Any "ROPE" CT Any "MOD" CT Any "MOD" CT Any "MOD" CT Any "MOD" CT

(800) 888-5538 | www.functionaldevices.com

163

POWER CONTROL
PSH600-UPS-STAT

POWER CONTROL

PSPT2RB4

PSM2RB10

PSMS1

PSMN24SB10

POWER CONTROL

SIB05S-RD

Enclosed Power Control Centers
· Two 120 Vac grounded convenience outlets · 4 or 10 Amp switch / circuit breaker · Outlets can be continuously powered or controlled
by the switch / circuit breaker. · True override switch on load side of relay · Auxiliary outputs are provided for convenient
control panel installations.
Track Mount Circuit Breaker Switches
· Track mount circuit breaker switches provide a convenient addition to control panels.
· Circuits can be low voltage (24 Vac) or line voltage (120 Vac).
Prepackaged Switches
· Standard configurations to provide simple switching schemes.
· Labels can be ordered with custom content to fit your project.

UPS Power Supplies
· Perfect for applications in hospitals, laboratories and research & surgery centers
· Keep your critical controller powered on during a loss of normal utility power with the ability to hardwire line voltage to the provided UPS, in addition to hardwiring the UPS to the final load.
· Kits include: 600 or 850 VA commercial UPS, NEMA 1 metal enclosure, and interface board
· BACnet® compatible model is BTL Certified and includes six objects: Line or UPS power, UPS percent load, VA load, UPS battery capacity, USB connection, and remaining battery time.
· Cords tuck inside enclosure for clean & neat use of a UPS.
· 120 Vac convenience outlet(s) provided
· 10 Amp circuit breaker / switch can be used to test functionality of UPS.
· Switch controls line voltage

164

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

POWER CONTROL

ENCLOSED POWER CONTROL CENTERS

MODEL # PSPT2RB4

120 VAC

OUTLETS

·

2

SWITCH On / Off

CIRCUIT BREAKER 4 Amp

PSPW2RB4

·

2

On / Off

4 Amp

PSPT2RB10

·

2

On / Off

10 Amp

PSPW2RB10

·

2

On / Off

10 Amp

HEIGHT 4.000 4.000 4.000 4.000

WIDTH 4.000 4.000 4.000 4.000

DEPTH 1.800 1.800 1.800 1.800

WIRES
· ·

TERMINALS
·
·

SPEC PAGE 166 166 166 166

TRACK MOUNT CIRCUIT BREAKER SWITCHES.

MODEL # PSMN01SB4 PSMN01SB10 PSMN24SB4 PSMN24SB10

POWER INPUT SWITCH LED

·

120 Vac

On / Off ·

·

120 Vac

On / Off ·

·

24 Vac

On / Off ·

·

24 Vac

On / Off ·

CIRCUIT BREAKER 4 Amp 10 Amp 4 Amp 10 Amp

HEIGHT 1.350 1.350 1.350 1.350

WIDTH 2.750 2.750 2.750 2.750

DEPTH 1 DEPTH 2 2.000 2.500 2.000 2.500 2.000 2.500 2.000 2.500

TRACK MOUNT MT212-2 included MT212-2 included MT212-2 included MT212-2 included

SPEC PAGE 166 166 166 166

PREPACKAGED SWITCHES

MODEL # PSMS1

RELAY CONTACTS
· 1 SPST

SWITCH Maintained 3 Position

SIB02S

· 1 SPDT

Maintained 3 Position

SIB04S

· 1 SPDT Maintained 2 Position (On / On)

SIB05S

· 1 SPST Maintained 2 Position (On / Off)

SIBLS

· 1 SPDT

Maintained 3 Position

SWITCH RATING 5 Amp @ 30 Vac/dc 20 Amp @ 277 Vac 20 Amp @ 277 Vac 20 Amp @ 277 Vac 5 Amp @ 30 Vac/dc

HEIGHT 1.280 1.700 1.700 1.700 1.700

WIDTH 4.000 2.800 2.800 2.800 2.800

DEPTH 1 1.250 1.500 1.500 1.500 1.500

DEPTH 2 ENCLOSED 1.750
· · · ·

TRACK MOUNT MT4 Series sold separately

SPEC PAGE 167 167 167 168 168

UPS POWER SUPPLIES.

MODEL # PSH600-UPS (Kit)#

CIRCUIT 120 VAC

TRACK

SPEC

STATUS UPS BREAKER OUTLET(S) COMPATIBLE

KIT

ENCLOSED MOUNT HEIGHT WIDTH DEPTH 1 DEPTH 2 PAGE

600 VA ·

·

N/A

·

12.000 14.000 6.000

169

PSH2RB10

·

·

·

PSH600-UPS

·

12.000 14.000 6.000

169

PSM2RB10

·

·

·

PSH600-UPS

MT4-4N included 3.250" 4.100" 1.250 1.750 170

PSMN2RB10

·

·

·

MT212-6N included 4.750" 2.750" 1.250 1.750 170

PSH600-UPS-STAT (Kit)#

· 600 VA ·

·

N/A

·

12.000 16.000 6.000

171

PSH2C2RB10

··

·

·

PSH600-UPS-STAT

·

12.000 16.000 6.000

172

PSMN2C2RB10

··

·

·

PSH600-UPS-STAT

MT212-6N included 6.660 2.750" 1.250 1.750 172

PSH850-UPS-STAT (Kit)*

· 850 VA ·

·

N/A

·

14.000 16.000 6.000

173

PSH2C2RB10-L

··

·

·

PSH850-UPS-STAT

·

14.000 16.000 6.000

173

PSH600-UPS-BC (Kit)#

· 600 VA ·

·

·

N/A

·

12.000 16.000 6.000

174

For full product information on "UPS" models, see our website.

= UL Listed - see data sheet for specific Listing

# = For replacement UPS order UPS600 * = For replacement UPS order UPS850

POWER CONTROL

(800) 888-5538 | www.functionaldevices.com

165

SWITCH / CIRCUIT BREAKER COMBOS

PSPT2RB4
Power Control Center, 4 Amp Switch / Circuit Breaker,
120 Vac, 2 Outlets, Terminals, NEMA 1 Housing

PSPT2RB10
Power Control Center, 10 Amp Switch / Circuit Breaker,
120 Vac, 2 Outlets, Terminals, NEMA 1 Housing

Outlets will always be energized when jumper is in this position.
INPUT

Outlets will be controlled by switch/breaker when jumper is in this position.
OUTPUT

Outlets will always be energized when jumper is in this position.
INPUT

Outlets will be controlled by switch/breaker when jumper is in this position.
OUTPUT

ALWAYS HOT SWITCHED
ALWAYS HOT SWITCHED

G

N

H

H

N

G

G

N

H

H

N

G

GND "G" and Neutral "N" pass from INPUT to OUTPUT uninterrupted.

Output Hot "H" is controlled by switch/breaker.

GND "G" and Neutral "N" pass from INPUT to OUTPUT uninterrupted.

Output Hot "H" is controlled by switch/breaker.

PSPW2RB4
Power Control Center, 4 Amp Switch / Circuit
Breaker, 120 Vac, 2 Outlets, Wires, NEMA 1 Housing

PSPW2RB10
Power Control Center, 10 Amp Switch / Circuit
Breaker, 120 Vac, 2 Outlets, Wires, NEMA 1 Housing

Green Wire
White Wire
Black Wire
ALWAYS HOT

Outlets will always be energized when jumper is in this position.

INPUT

G

N

H

SWITCHED

Blue Wire

Outlets will be controlled by switch/breaker when jumper is in this position.

OUTPUT

H

N

G

Outlets will always be energized when jumper is in this position.

INPUT

G

N

H

BLUE = LOAD Blue wire is controlled by switch/breaker.

Green Wire
White Wire
Black Wire
ALWAYS HOT

SWITCHED

Blue Wire

Outlets will be controlled by switch/breaker when jumper is in this position.

OUTPUT

H

N

G

BLUE = LOAD Blue wire is controlled by switch/breaker.

AT4 SERIES SELECTION GUIDE

Model # PSPT2RB4 PSPT2RB10 PSPW2RB4 PSPW2RB10

Circuit Breaker 4 Amps 10 Amps 4 Amps 10 Amps

Terminals · ·

Wires
· ·

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Circuit Breaker: 4 Amp Max. or 10 Amp Max. Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50"NPT nipple Housing Detail: See Housing C in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated (PSPW2RB4 & PSPW2RB10) Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Terminals: Ground "G and Neutral "N pass from INPUT to OUTPUT uninterrupted. OUTPUT Hot blue wire is controlled by the switch/breaker.
TRACK MOUNT CIRCUIT BREAKER SWITCHES

Notes: · Indicator light will illuminate when switch/breaker is ON (RESET position) indicating power has been transferred from INPUT to OUTPUT by the switch/breaker. If it is desired for the indicator light to be illuminated continuously to indicate the presence of input (Line) power, INPUT and OUTPUT may be reversed -- connect input power from line to OUTPUT and connect output load to INPUT (operation of the jumpers above also reverses).

PSMN01S SERIES
Switch, 2 Position Maintained, On/Off, 4 Amp or 10 Amp Circuit Breaker, 120 Vac, 2.75" Track Mount
Temperature Compensation 1.40

PSMN24S SERIES
Switch, 2 Position Maintained, On/Off, 4 Amp or 10 Amp Circuit Breaker, 24 Vac, 2.75" Track Mount
Temperature Compensation 1.40

1.30

1.30

1.20

1.20

1.10

1.10

1.00

1.00

0.90

0.90

0.80

0.80

0.70

0.70

0.60 -20 -10 0 10 20 30 40 50 60
Ambient Temperature in Degrees Centigrade (ºC)

0.60 -20 -10 0 10 20 30 40 50 60
Ambient Temperature in Degrees Centigrade (ºC)

PSMN01S SERIES

Model #

Circuit Breaker

PSMN01SB4

4 Amps

PSMN01SB10

10 Amps

SPECIFICATIONS

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Circuit Breaker: 4 Amp or 10 Amp Dimensions: 1.35"H x 2.75"W x 2.00"D1/2.50"D2

PSMN24S SERIES

Model #

Circuit Breaker

PSMN24SB4

4 Amps

PSMN24SB10

10 Amps

Housing Detail: See Housing H in housing guide for dimensions

Origin: Made of US and non-US parts Track Mount: MT212-2 Mounting Track Provided

OVER CURRENT / SHORT CIRCUIT PROTECTION AND SWITCHING

Approvals: UL Listed, UL916, C-UL, CE, RoHS

Blk

120 Vac

Wht

ON OFF

Load

POWER CONTROL
Correction Factor Correction Factor

166

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

PREPACKAGED SWITCH
PSMS1
Switch, 3 Position Maintained, 5 Amp, 30 Vac/dc, 4.00" Track Mount

Power Input Vac/dc (+ if DC)
Controller DO
Comm (- if DC)

CLOSED

Green OPEN

OUT

AUTO Red

Yellow

Comm (- if DC)

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.28"H x 4.00"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts Track Mount: 4.000 MT4 Mounting Track Sold Separately
PREPACKAGED SWITCH
SIB02S
Switch, 20 Amp, 3 Position Maintained, Center Off, 3 Wires, NEMA 1 Housing
Blu

Switch Status: Green LED On = Power Input present Yellow LED On = Controller DO ON Red LED On = Output Signal ON
Approvals: UL Listed, UL916, C-UL, CE, RoHS

Switch Ratings: 5 Amp @ 30 Vac/dc

CLOSED

OPEN

Yel

AUTO

Org

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1

Switch Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 10 Amp Tungsten @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

PREPACKAGED SWITCH
SIB04S
Switch, 20 Amp, 2 Position Maintained, On/On, 3 Wires, NEMA 1 Housing

Blu

SIB02S-RD · Red housing
Notes: · Switch position label can be custom printed according to your needs, simply consult factory

CLOSED Yel
AUTO
Org

SIB04S-RD · Red housing

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1

Switch Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 10 Amp Tungsten @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac

Notes: · Switch position label can be custom printed according to your needs, simply consult factory

(800) 888-5538 | www.functionaldevices.com

167

POWER CONTROL

PREPACKAGED SWITCH
SIB05S
Switch, 20 Amp, 2 Position Maintained, On/Off, 2 Wires, NEMA 1 Housing

Org
ON Org
OFF

SIB05S-RD · Red housing

SPECIFICATIONS

Operating Temperature: -30 to 140° F

Switch Ratings:

Humidity Range: 5 to 95% (noncondensing)

20 Amp Resistive @ 277 Vac

Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple 1110 VA Pilot Duty @ 277 Vac

Housing Detail: See Housing A in housing guide for dimensions 770 VA Pilot Duty @ 120 Vac

Origin: Made of US and non-US parts

20 Amp Ballast @ 277 Vac

Wires: 16, 600V Rated

10 Amp Tungsten @ 120 Vac

Approvals: UL Listed, UL916, C-UL, CE, RoHS

2 HP @ 277 Vac

Housing Rating: UL Accepted for Use in Plenum, NEMA 1

1 HP @ 120 Vac

PREPACKAGED SWITCH
SIBLS
Switch, 5 Amp, 30 Vac/dc, 3 Position Maintained, On/Off/On, LED Indicator, NEMA 1 Housing

Wht/Blu ( + if d/c)

Notes: · Switch position label can be custom printed according to your needs, simply consult factory

CLOSED OPEN AUTO
Brn ( + if d/c)

Org
Wht/Yel ( ­ if d/c) *

SIBLS-RD · Red housing

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.70"H x 2.80"W x 1.50"D with 0.50"NPT nipple Housing Detail: See Housing A in housing guide for dimensions Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Switch Rating: 5 Amp @ 30Vac/dc

Notes: · Switch position label can be custom printed according to your needs, simply consult factory · Connection to Wht/Yel may be omitted if LED is not needed *

POWER CONTROL

168

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

UNINTERUPTABLE POWER SUPPLY KIT

PSH600-UPS
600VA UPS Backup Power Control Center, 12" x 14" x 6" Metal Enclosure

UPS
(Not Included)

120 Vac On/O Switch, Breaker Line Input & Indicator Light

}

UPS Output GND Neut. Hot

GND

Line Input

Hot

RESET OFF

Neut.

Shown Without Cover

GND

Neut.

Hot

From UPS

}

To UPS
To Protected Device

Computer Outlet

To UPS

SPECIFICATIONS

UPS
UPS: 600VA Backup Time: 2.5 Min. @ Full 600 VA Load
10 Min. @ 1/2 Load Power Consumption Up to 3 Amp @120 Vac
Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778
PSH2RB10
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS
Dimensions: 12.000 H x 14.000 W x 6.000 D Metal Housing with Screw Cover
Origin: Made of US and non-US parts

Notes: · To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2RB10. · To order interface board for replacement or for separate use, order model PSMN2RB10. · Average battery life: 3-5 years depending on the number of discharge cycles and environmental temperature · UPS may change based on quality and availability

UNINTERUPTABLE POWER SUPPLY KIT
PSH2RB10
UPS Power Control Center, 2.75" Track Mount in 12" x 14" x 6" Metal Enclosure

UPS
(Not Included)

120 Vac On/O Switch, Breaker Line Input & Indicator Light

}

UPS Output GND Neut. Hot

GND

Line Input

Hot

RESET OFF

Backup Time (Minutes)

ESTIMATED BACKUP TIME VS. LOAD
Load (Watts) Shown With Cover

Neut.

GND

Neut.

Hot

From UPS

}

To UPS
To Protected Device

Computer Outlet

To UPS

Shown Without Cover

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS
Dimensions: 12.000 H x 14.000 W x 6.000 D Metal Housing with Screw Cover
Origin: Made of US and non-US parts

Notes: · Track mounted interface board may be ordered separately as model PSMN2RB10, to be used with any commercial UPS with appropriate ratings for the circuit breaker. · Circuit breaker for short protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less.
· Max. size: 12.000 x 7.250 x 5.500 · 120 Vac max., 600 W max., 8.3 Amp max. · UPS is not included.

POWER CONTROL

(800) 888-5538 | www.functionaldevices.com

169

UPS INTERFACE MODULE

PSM2RB10
UPS Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac,
2 Outlets, Terminals, 4.00" Track Mount

UPS
(Not Included)

}

To Protected 120 Vac On/O Switch, Breaker

Device Line Input

& Indicator Light

}

UPS Output

Line Input

RESET

Hot

OFF

Neut.

GND GND

Neut.

Hot

To UPS

Computer Outlet

BUY SEPARATELY AND PLACE IN AN ENCLOSURE
OF YOUR CHOICE

From UPS

To UPS

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 3.25"H x 4.10"W x 1.25"D1/1.75"D2
Housing Detail: See Housing H in housing guide for dimensions Track Mount: 3.250 x 4.000 MT4-4N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS Origin: Made of US and non-US parts

UPS INTERFACE MODULE

Notes: · Circuit breaker for short protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · UPS is not included.

PSMN2RB10
UPS Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac,
2 Outlets, Terminals, 2.75" Track Mount

120 Vac On/O Switch, Breaker

Line Input

& Indicator Light

}

UPS

(Not Included)

UPS Output

Line Input

RESET

GND
UPS INTERFACE MONeDutU. LE

Hot

GND

Hot

OFF

Neut.

GND

Neut.

Hot

From UPS

}

To UPS
To Protected Device

Computer Outlet

To UPS

BUY SEPARATELY AND PLACE IN AN ENCLOSURE
OF YOUR CHOICE

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 4.75"H x 2.75"W x 1.25"D1/1.75"D2
Housng Detail: See Housing H in housing guide for dimensions Origin: Made of US and non-US parts
Track Mount: 2.750 x 6.000 MT212-6N Mounting Track Included
Approvals: UL Listed, UL916, C-UL, CE, RoHS

Notes: · Circuit breaker for short protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · UPS is not included.

POWER CONTROL

170

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

UNINTERUPTABLE POWER SUPPLY KIT

PSH600-UPS-STAT
600VA UPS Backup Power Control Center, Status Contacts, 12" x 14" x 6" Metal Enclosure

UPS Status Contacts & 120 Vac LED Indicator Line Input

Input Power Status Contacts & LED Indicator

}

GND }
Neut. Line

N/C }
COM N/O

N/C COM N/O

UPS

GND Neut. Line

RESET OFF

Shown Without Cover

Line

Neut.

GND

From UPS Backed Up Outlet

}
}

To Protected Device
To UPS

UPS plugged into one of two outlets. Other outlet is spare.

SPECIFICATIONS

UPS
UPS: 550 or 600VA Backup Time: 2.5 Min. @ Full 600 VA Load
10 Min. @ 1/2 Load Power Consumption Up to 3 Amp @120 Vac
Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778

Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc (N/O) 7 Amp @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 1000 VA @ 120 Vac Magnetic Ballast (N/C) C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty

PSH2C2RB10
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS
Dimensions: 12.000 H x 14.000 W x 6.000 D Metal Housing with Screw Cover
Origin: Made of US and non-US parts

Notes: · To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2C2RB10. · To order interface board for replacement or for separate use, order model PSMN2C2RB10. · Average battery life: 3-5 years depending on the number of discharge cycles and environmental temperature · UPS may change based on quality and availability

Backup Time (Minutes)

ESTIMATED BACKUP TIME VS. LOAD
Load (Watts)

UPS Status Contacts and LED Indicator
The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on.

Input Power Status Contacts and LED Indicator
The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is de-energized, and the LED is off.

POWER CONTROL

(800) 888-5538 | www.functionaldevices.com

171

ENCLOSED UPS INTERFACE MODULE

PSH2C2RB10
UPS Power Control Center Interface Board, Status Contacts,
2.75" Track Mount in 12" x 16" x 6" Metal Enclosure

UPS
(Not Included)

UPS Status Contacts & 120 Vac LED Indicator Line Input

Input Power Status Contacts & LED Indicator

GND }
Neut. Line

N/C }
COM N/O

N/C COM N/O

GND Neut. Line

RESET OFF

}

Shown With Cover

Line

Neut.

GND

}

From UPS Backed-Up
Outlet

To Protected Device
To UPS

UPS plugged into one of two outlets. Other
outlet spare.

}

Shown Without Cover

SPECIFICATIONS
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS, NEMA 1
Dimensions: 4.75"H x 2.75"W x 1.25"D1/1.75"D2 Housing Detail: See Housing H in housing guide for dimensions
Metal Housing with Screw Cover Origin: Made of US and non-US parts
UPS Status Contacts and LED Indicator The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on.

Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc N/O 7 Amp @ 30 Vdc N/C 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 100 VA @ 120 Vac Ballast N/C C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty

Notes: · Track mounted interface board may be ordered separately as model PSMN2C2RB10, to be used with any commercial UPS with appropriate ratings for the circuit breaker. · Circuit breaker for short-circuit protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less.
· Max. size: 12.000 x 7.250 x 5.500 · 120 Vac max., 600 W max., 8.3 Amp max. · UPS is not included.

Input Power Status Contacts and LED Indicator
The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is de-energized, and the LED is off.

UPS INTERFACE MODULE

PSMN2C2RB10
UPS Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac,
2 Outlets, Terminals, Status Contacts, 2.75" Track Mount

}

UPS
(Not Included)

UPS Status Contacts & 120 Vac LED Indicator Line Input

Input Power Status Contacts & LED Indicator

GND }
Neut. Line

N/C }
COM N/O

N/C COM N/O

GND Neut. Line

RESET OFF

POWER CONTROL

Line

Neut.

GND

}

}

From UPS Backed-Up
Outlet

To Protected Device
To UPS

UPS plugged into one of two outlets. Other
outlet spare.

BUY SEPARATELY AND PLACE IN AN ENCLOSURE OF YOUR CHOICE

SPECIFICATIONS

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 6.66"H x 2.75"W x 1.25"D1/1.75"D2
Housing Detail: See Housing H in housing guide for dimensions Track Mount: 2.750 x 6.000 MT212-6N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS Origin: Made of US and non-US parts

Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc N/O 7 Amp @ 30 Vdc N/C 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 100 VA @ 120 Vac Ballast N/C C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty

Notes: · Circuit breaker for short-circuit protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · UPS is not included.

UPS Status Contacts and LED Indicator
The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on.

Input Power Status Contacts and LED Indicator
The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is de-energized, and the LED is off.

172

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

UNINTERUPTABLE POWER SUPPLY KIT

PSH850-UPS-STAT
850VA UPS Backup Power Control Center, Status Contacts, 14" x 16" x 6" Metal Enclosure

UPS

UPS Status Contacts & 120 Vac LED Indicator Line Input

Input Power Status Contacts & LED Indicator

GND }
Neut. Line

N/C }
COM N/O

N/C COM N/O

GND Neut. Line

RESET OFF

}

Shown Without Cover

Shown With Cover

Line

Neut.

GND

From UPS Backed Up Outlet

}

To Protected Device
To UPS

UPS plugged into one of two outlets. Other
outlet spare.

}

SINUSOIDAL OUTPUT OR PURE SINE WAVE OUTPUT

SPECIFICATIONS

UPS
UPS: 850VA Backup Time: 2 Min. @ Full 850 VA Load
8 Min. @ 1/2 Load Input: 120 Vac, 12 Amp Sine Wave Output: 120 Vac, 7.1 Amp Max Load: 510 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 95° F UPS Transfer Time: 4ms Approvals: UL Listed, UL1778 Model: Cyber Power Model 850PFCLCD PSH2C2RB10-L
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS
Dimensions: 14.000 H x 16.000 W x 6.000D Metal Housing with Screw Cover
Origin: Made of US and non-US parts

Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc (N/O) 7 Amp @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 1000 VA @ 120 Vac Magnetic Ballast (N/C) C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty

Backup Time (Minutes)

ESTIMATED BACKUP TIME VS. LOAD
70 60 50 40 30 20 10

Notes: · To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2C2RB10-L. · To order interface board for replacement or for separate use, order model PSMN2C2RB10. · Typical battery life: 3-6 years, depending on number of discharge/recharge cycles

0

0

100

200

300

400

500 550

Load (Watts)

UPS Status Contacts and LED Indicator
The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on.

Input Power Status Contacts and LED Indicator

The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is deenergized, and the LED is off.

ENCLOSED UPS INTERFACE MODULE

PSH2C2RB10-L
UPS Power Control Center Interface Board, Status Contacts, 2.75"Track Mount in
14" x 16" x 6" Metal Enclosure

UPS Status Contacts & 120 Vac LED Indicator Line Input

Input Power Status Contacts & LED Indicator

}

GND }
Neut. Line

N/C }
COM N/O

UPS
(Not Included)

GND Neut. Line

RESET OFF

N/C COM N/O

Shown Without Cover

Shown With Cover

Line

Neut.

GND

From UPS Backed Up Outlet

}

To Protected Device

To UPS

SPECIFICATIONS

}

UPS plugged into one of two outlets. Other
outlet spare.

Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS
Dimensions: 14.000H x 16.000W x 6.000D Metal Housing with Screw Cover
Origin: Made of US and non-US parts

Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc N/O 7 Amp @ 30 Vdc N/C 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 1000 VA @ 120 Vac Magnetic Ballast N/C C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty

Notes: · Track mounted interface board may be ordered separately as model PSMN2C2RB10, to be used with any commercial UPS with appropriate ratings for the circuit breaker. · Circuit breaker for short-circuit protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less.
· Max. size: 14.000 x 10.000 x 5.500 · 120 Vac, 600 W max., 8.3 Amp max. · UPS is not included. · To order a kit with a UPS, see PSH850-UPS-STAT.

UPS Status Contacts and LED Indicator
The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on.

Input Power Status Contacts and LED Indicator
The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is de-energized, and the LED is off.

(800) 888-5538 | www.functionaldevices.com

173

POWER CONTROL

UNINTERUPTABLE POWER SUPPLY KIT - BACNET COMPATIBLE
PSH600-UPS-BC
600 VA UPS Backup Power Control Center, BACnet MS/TP Network, 12" x 14" x 6" Metal Enclosure

UPS

Line Neut. Gnd. Gnd. Neut. Line Red LED = Device Power Pink LED = Device Status Green LED = Network Comm.

}

UPS Output to protected
device Line Input
RESET
OFF
1 2 3 4 5 6 7 8 9 10 OPEN
UPS plugged into one of two outlets. Other outlet spare.

EOL Jumper
Yellow LED = Backup Power
Blue LED = USB Status

B(+) A(-) BACnet® REF comm.
USB Jack

To UPS

Shown Without Cover

SPECIFICATIONS

BOARD AND ENCLOSURE:
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Indicators: Device Power: Red LED Device Status: Pink LED Network Communication: Green LED Backup Power: Yellow LED USB Status: Blue LED
Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 12" H x 14 W x 6 D Origin: Made of US and non-US parts Track Mount: 2.750 x 8.000 MT212-8N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS Line Input: 120Vac, 10A(max)
Convenience Receptacles: 120Vac, 10A(max combined)
UPS:
UPS: 600VA Backup Time: 2.5 Min. @ Full 600 VA Load
10.2 Min. @ 1/2 Load Input: 120 Vac, 12 Amp Output: 120 Vac, 4.6 Amp Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778

Power Input Rating:

Notes:

25mA @ 120Vac

· Circuit breaker for short-circuit protection.

Network Media:

· 14/3 Line Cord included (3´).

Twisted Pair 22-24 AWG, shielded recommended (MS/TP)

USB A/B (device to UPS, included)

BACnet® Details:

Terminations:

· MS/TP Address & Baud Rate must be set prior

Functional Devices product installed at both ends of the

to power up via DIP switches.

MS/TP network - Use 120 Ohm End of Line Resistors. All

· Device ID will default to 277XXX where XXX is

other cases follow instructions from the device installed

the MS/TP Address.

at the end of the MS/TP network.

Examples:

Polarity: Network is polarity sensitive. Baud Rate: 9600, 192000, 38400, 76800, 115200 ( DIP Switch Selectable)

MS/TP Address - 004 Device ID - 277004
MS/TP Address - 121 Device ID - 277121

DIP SWITCHES*

8

9

10

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

BAUD RATE
9600 19200 38400 57600 76800 115200

· Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Devices Instance changed via Object Identifier Property of Device Object. · Status of UPS connection, Battery run time, line power ,UPS load (VA and %), and battery capacity can be read from BACnet network.

All other combinations=9600 baud

ESTIMATED BACKUP TIME VS. LOAD
60

Notes:

· Average battery life: 3-5 years depending on the number of discharge

50

cycles and environmental temperature

· This model is not designed to notify user of battery failure. · This model is designed to work exclusively with Functional Devices Model UPS600

40

INFORMATION PROVIDED OVER BACNET® NETWORK CAN BE USED TO SCHEDULE "PREDICTIVE MAINTENANCE" SUCH AS UPS BATTERY REPLACEMENT, ETC.

30 20

10

0

0

50 100 150 200 250 300 350

Load (Watts)

POWER CONTROL Backup Time (Minutes)

174

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

HVAC & LIGHTING ENERGY MANAGEMENT

Gateway/BMS
Key Card Switch
controls access to a room and turns on heating and lighting
when entering a room

Position Sensors
set back HVAC when windows are open

Occupancy Sensor
adjusts temperature and turns off lights when a
room is not in use
Batteryless Wireless Switches
control lighting

WIRELESS DEVICES

YOUR PAYBACK/ROI
· 70% COST SAVINGS IN RETROFITS · 40% ENERGY SAVINGS · UNLIMITED FLEXIBILITY
902 MHz · Maintenance-free Flexibility of applications · Time saving Cost savings in installation, renovation, and energy usage

Many hotels keep their rooms at a comfortable temperature for the duration of their guests' stays ­ whether the guests are in or out of their room. With guest comfort as a priority, hotels and motels typically use almost 40 percent of their electricity on heating and cooling rooms, even though studies show that most sold rooms are unoccupied for 12 or more hours a day. Used correctly, the right controls could offer significant energy savings without compromising the comfort of guests.
Information from: EnOcean® Alliance & ENERGY STAR Building Upgrade Manual

(800) 888-5538 | www.functionaldevices.com

175

ENOCEAN® ENABLED WIRELESS DEVICES

RIBW01B-EN3

RIBW01C-EN3

WDWS2-EN3

WWS2-EN3

WKC-EN3

WVSCM-EN3

WVSWM-EN3

EnOcean® Enabled Wireless RIB® Relay Receivers & Transceivers work in conjunction with many 902 MHz EnOcean® enabled transmitters.

Wireless wall switches, occupancy sensors, thermostats, key card switches, and patio & door switches are all devices which can activate the RIB® Wireless Control Relays by using EnOcean's "energy harvesting" technology. Energy harvesting refers to the process by which energy is captured and stored, then used to transmit a wireless signal, which in turn is received by the RIB® Wireless Relay.

WIRELESS CONTROL RELAYS

COIL VOLTAGE

CONTACT RATINGS

MODEL #

RELAY AC/DC AC CONTACTS RESISTIVE

MOTOR

REPEAT DRY CONTACT DIMMER HOUSING

SPEC

PILOT DUTY FUNCTION INPUT FUNCTION STYLE * FREQUENCY PAGE

RIBW01B-EN3 ·

120 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 177

RIBW208B-EN3 ·

208 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 177

RIBW240B-EN3 ·

240 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 177

RIBW277B-EN3 ·

277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 177

RIBW24B-EN3 · 24

1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 177

RIBW21BAO-EN3 ·

120-277 1 SPDT 20 A @ 277 Vac 2 HP @ 277 Vac 1,110 VA @ 277 Vac ·

·

B

902 MHz 178

RIBW01C-EN3 ·

120 1 SPST 5 A Ballast @ 120/277 Vac; 5 A Elec. Ballast @ 120 Vac ·

Ballast size 902 MHz 178

RIBW02C-EN3 ·

208-277 1 SPST 5 A Ballast @ 120/277 Vac; 5 A Elec. Ballast @ 120 Vac ·

Ballast size 902 MHz 178

WIRELESS PHASE ANGLE DIMMER

POWER INPUT

MODEL #
RIBW01F600-EN3 ·

AC/DC

AC 120 Vac

REPEAT

DRY CONTACT

DIMMER

HOUSING

SPEC

FUNCTION

INPUT

FUNCTION

STYLE *

FREQUENCY

PAGE

·

·

C

902 MHz

179

WIRELESS TRANSMITTERS

MODEL # WWS2-EN3

DESCRIPTION Wall switch with barrier & cover plate

POWER INPUT Self-Powered

ENOCEAN® ENERGY HARVESTING
·

FREQUENCY 902 MHz

COLOR White

SPEC PAGE
180

WDWS2-EN3

Door and window switch

Light-Powered

·

902 MHz

White

180

WKC-EN3

Keycard switch

Self-Powered

·

902 MHz

White

180

WVSCM-EN3

Occupancy / vacancy sensor, ceiling mount

Light-Powered

·

902 MHz

White

181

WVSWM-EN3

Occupancy / vacancy sensor, wall mount

Light-Powered

·

902 MHz

White

181

WVSUS-EN3

Occupancy / vacancy sensor, ceiling mount

Light-Powered

·

902 MHz

White

182

WIRELESS ACCESSORIES

MODEL # AWSTFM WSTP-W

DESCRIPTION Flush Surface Mount Backplate Kit for WWS2-EN3 Wall Switch Plate Replacement

SPEC PAGE 182
182

= UL Listed - see data sheet for specific Listing

* = See Housing Guide on page 201

176

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

WIRELESS DEVICES

WIRELESS CONTROL RELAYS WITH TWO-WAY COMMUNICATION

RIBW01B-EN3
EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT, 120 Vac Power Input, Dry Contact Input, NEMA 1 Housing
RIBW208B-EN3
EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT, 208 Vac Power Input, Dry Contact Input, NEMA 1 Housing
RIBW240B-EN3
EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT, 240 Vac Power Input, Dry Contact Input, NEMA 1 Housing

Blu N/C

Blk

120 Vac (RIBW01B-EN3)

Yel

208 Vac (RIBW208B-EN3)

C

240 Vac (RIBW240B-EN3)

277 Vac (RIBW277B-EN3)

Wireless

Org

Receiver

N/O

Wht Neutral or Other Phase

Control Circuit

Wht/Red Wht/Blu

RIBW01B-EN3 RIBW208B-EN3 RIBW240B-EN3 RIBW277B-EN3

Blu N/C

RIBW277B-EN3
EnOcean 902 MHz Wireless Relay, Transceiver
/ Repeater, 20 Amp SPDT, 277 Vac Power
Input, Dry Contact Input, NEMA 1 Housing

Yel

Wht/Yel

C

24 Vac/dc

Wht/Yel 24 Vac/dc

Wireless

Org

Transceiver

N/O

Control

Circuit

RIBW24B-EN3
EnOcean 902 MHz Wireless Relay, Transceiver
/ Repeater, 20 Amp SPDT, 24 Vac/dc Power
Input, Dry Contact Input, NEMA 1 Housing

Wht/Red Wht/Blu

RIBW24B-EN3

Learn Clear
RELAY HAS BUILT-IN REPEATER FUNCTION. RELAY RECEIVES SIGNAL FROM WIRELESS SWITCH TRANSMITTER AND REBROADCASTS THE SIGNAL
TO THE NEXT RELAY RECEIVER.

SPECIFICATIONS

# Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical
Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Red LED: Relay Status / Learn Mode Status (Flashing) Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.50" NPT nipple Housing Details: See Housing B in housing guide for
demensions Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, RoHS Agency Compliance: FCCID: SZV-TCM320U
IC: 5713A-TCM320U Housing Rating: UL Accepted for Use in Plenum, NEMA 1
Gold Flash: No Override Switch: No
Frequency: 902 MHz Receiver Sensitivity: -93 dBm typical
Conducted Power: 5 mW typical Built-in Switch Modes: Alarm, Repeater, Delay, Rocker,
Momentary, and Toggle Origin: Made of US and non-US parts

Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac
Power Input Ratings: 73 mA @ 120 Vac ; 60 Hz (RIBW01B-EN3) 80 mA @ 208 Vac ; 60 Hz (RIBW208B-EN3) 80 mA @ 240 Vac ; 60 Hz (RIBW240B-EN3) 80 mA @ 277 Vac ; 60 Hz (RIBW277B-EN3) 69 mA @ 24 Vdc (RIBW24B-EN3) 139 mA @ 24 Vac (RIBW24B-EN3)

Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft.
· Open area transmission could be farther. Consult factory for more information.
· Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used. · Version 1.5 firmware or later implements Functional Devices, Inc.'s EnOcean® Manufacturer ID of 0x055. · For setup instructions, see website for -EN3 Series Application Manual: www.functionaldevices.com/wp-content/uploads/2021/12/ B1867_393231.pdf

APPLICATION FOR WIRELESS CONTROL & FEEDBACK IN A BUILDING AUTOMATION SYSTEM

BAS Panel
Wht/Red and Wht/Blu DO

Org Wht/Yel

Wht 60Hz A/C Power

DI

Yel

Load

Current

Sensor

Wht/Red Wht/Blu
Dry contact input for load veri cation

BAS Controller
Org Yel
WIRELESS DEVICES

(800) 888-5538 | www.functionaldevices.com

177

WIRELESS CONTROL RELAY

RIBW21BAO-EN3
EnOcean 902 MHz Wireless Relay, Transceiver / Repeater, 20 Amp SPDT,
120-277 Vac Power Input, 0-10 Vdc Analog Output, NEMA 1 Housing

Blu N/C

Yel C Blk 120-277 Vac

Wireless

Org

Transceiver

N/O

Red Neutral or

Control

Other Phase

Circuit

Prp 0-10Vdc
Gry Com

RELAY HAS BUILT-IN REPEATER FUNCTION. RELAY RECEIVES SIGNAL FROM WIRELESS SWITCH
TRANSMITTER AND REBROADCASTS THE SIGNAL TO THE NEXT RELAY
RECEIVER.

Learn Clear

SPECIFICATIONS

# Relays & Contact Type: One (1) SPDT Continuous Duty Coil

Contact Ratings:

Expected Relay Life: 10 million cycles minimum mechanical

20 Amp Resistive @ 277 Vac

Operating Temperature: -30 to 140° F

20 Amp Ballast @ 277 Vac (N/O)

Humidity Range: 5 to 95% (noncondensing)

10 Amp Ballast @ 277Vac (N/C)

Red LED: Relay Status / Learn Mode Status (Flashing)

16 Amp Electronic Ballast @ 277 Vac (N/O)

Dimensions: 2.39"H x 3.31"W x 1.81"D with 0.75" NPT nipple 10 Amp Tungsten @ 120 Vac (N/O)

Housing Detail: See Housing B in housing guide for demensions 770 VA Pilot Duty @ 120 Vac

Wires: 16, 600V Rated

1,110 VA Pilot Duty @ 277 Vac

Approvals: UL Listed, UL916, C-UL, RoHs

2 HP @ 277 Vac

Agency Compliance: FCCID: SZV-TCM320U

1 HP @ 120 Vac

IC: 5713A-TCM320U Housing Rating: UL Accepted for Use in Plenum, NEMA 1
Gold Flash: No Override Switch: No
Frequency: 902 MHz

Power Input Ratings: 39 mA max @ 120-277Vac
Analog Output Ratings: 0-10Vdc, 10mA Sourcing/ 50mA Sinking

Receiver Sensitivity: -93 dBm typical

Conducted Power: 5 mW typical

Built-in Switch Modes: Alarm, Repeater, Delay, Dimming, Rocker, Momentary, and Toggle

Origin: Made of US and non-US parts

Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft.
· Open area transmission could be farther. Consult factory for more information.
· Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used.
· For setup instructions, see website.

WIRELESS CONTROL RELAYS WITH TWO-WAY COMMUNICATION

RIBW01C-EN3
EnOcean 902 MHz Wireless Relay, Receiver/
Repeater, 5 Amp SPST-N/O, 120 Vac Power
Input, NEMA 1 Housing

RIBW02C-EN3
EnOcean 902 MHz Wireless Relay, Receiver/
Repeater, 5 Amp SPST-N/O, 208-277 Vac
Power Input, NEMA 1 Housing

WIRELESS DEVICES

Org N/O
Blk 120 Vac

Wireless

Org

Receiver

N/O

Wht

Control

Neutral

Circuit

Org N/O
Blk 208-277 Vac

Wireless

Org

Red Neutral or

Receiver Control

N/O

Other Phase

Circuit

SMALLER SIZE DESIGN TO FIT INSIDE BALLAST HOUSING OF FLUORESCENT LIGHT FIXTURE.

SPECIFICATIONS

# Relays & Contact Type: One (1) SPST Continuous Duty Coil

Contact Ratings:

Expected Relay Life: 10 million cycles minimum mechanical

5 Amp Ballast @ 120/277 Vac

Operating Temperature: -30 to 140° F

5 Amp Tungsten @ 120 Vac

Humidity Range: 5 to 95% (noncondensing)

5 Amp Electronic Ballast @ 120 Vac

Red LED: Relay Status / Learn Mode Status (Flashing) Dimensions: 1.68"H x 4.58"W x 1.18"D Housing Detail: See Housing E in housing guide for demensions
Wires: 16, 600V Rated

Power Input Ratings: 75 mA @ 120 Vac ; 60 Hz (RIBW01C-EN3) 100 mA @ 208-277 Vac ; 60 Hz (RIBW02C-EN3)

Approvals: UL Listed, UL916, C-UL, RoHS

Agency Compliance: FCCID: SZV-TCM320U ; IC: 5713A-TCM320U

Gold Flash: No

Override Switch: No

Frequency: 902 MHz

Receiver Sensitivity: -93 dBm typical

Conducted Power: 5 mW typical

Built-in Switch Modes: Alarm, Repeater, Delay, Rocker, Momentary, and Toggle

Origin: Made of US and non-US parts

Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft.
· Open area transmission could be farther. Consult factory for more information.
· Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used. · Version 1.5 firmware or later implements Functional Devices, Inc.'s EnOcean® Manufacturer ID of 0x055. · For setup instructions, see website for -EN3 Series: www.functionaldevices.com/wp-content/uploads/2021/12/ B1867_393231.pdf

178

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

WIRELESS CONTROL PHASE ANGLE DIMMER

RIBW01F600-EN3

EnOcean 902 MHz Wireless Phase Angle Dimmer,

Receiver / Repeater, 120 Vac Power Input, 600W

Rated, Dimming Mode Selectable, NEMA 1 Housing

Blk 120 Vac

DIMMER HAS BUILT-IN REPEATER FUNCTION. DIMMER
RECEIVES SIGNAL FROM WIRELESS TRANSMITTER AND REBROADCASTS THE SIGNAL TO THE NEXT RELAY RECEIVER.

Wht Neutral
Red Dimmed Hot

Wireless Receiver Control Circuit

SPECIFICATIONS

Operating Temperature: -30 to 122 F Humidity Range: 5 to 95% (noncondensing) Red LED: Learn Mode Status (Flashing) / Dim Mode Status Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT nipple Housing Detail: See Housing C in housing guide for demensions Wires: 16", 600V rated Approvals: UL Listed, UL916, C-UL, RoHS
Agency Compliance: FCCID: SZV-TCM320U IC: 5713A-TCM320U
Housing Rating: UL Accepted, NEMA 1 Frequency: 902 MHz
Max Lighting Load: 600W Incndescent/Halogen Recommended 300W for other dimmable lighting loads
Selectable Dimming Mode: Yes
Selectable Low Dim Threshold: Yes Origin: Made of US and non-US parts

Power Input Ratings: 100mA @ 120 Vac; 60Hz

Clear Learn
Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft.
· Open area transmission could be farther. Consult factory for more information.
· Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used. · Version 1.5 firmware or later implements Functional Devices, Inc.'s EnOcean® Manufacturer ID of 0x055. · Not for use with Magnetic Low Voltage (MLV) loads.

TYPICAL APPLICATION

EnOcean Enabled Transmitter

RIBW01F600-EN3
Black White
Red

120Vac Power
Phase Dimmable Lighting Load

WIRELESS DEVICES

(800) 888-5538 | www.functionaldevices.com

179

WIRELESS ROCKER SWITCH TRANSMITTER & COVER PLATE
WWS2-EN3
EnOcean 902 MHz Wireless Wall Transmitter Switch with Barrier and Cover Plate, White
Includes Cover Plate.

SPECIFICATIONS

Operating Modes: On/Off, Toggle, Scene control

Power Supply: Powered by finger press

(Electrodynamic Energy Harvester)

Frequency: 902 MHz

Antenna: Integrated antenna, 6.4 cm

Transmission Power: Max. 10mW EIRP

Energy Bowtravel/Operating Force: 50,000 actuations tested to EN60669 / VDE 0632

Operating Temperature: -25 to 65° C

Relative Humidity 5 to 92% (noncondensing)

Dimensions: 2.75H x 4.50W x 0.8D

Approvals: RoHS

Agency Compliance: · Switch

· Barrier Plate

FCC ID: SZV-PTM210U Certified to UL514D

IC: 5713A-PTM210U CSA C22.2 #42-1-13

Notes: · Control one load or one group of loads with a single rocker style Wireless Switch Transmitter. · Typical range: 50-150 ft.
· Open area transmission could be farther. Consult factory for more information. · Mounting
· Includes barrier plate and mounts to electrical wall boxes (screws included). · Alternate surface mount accessory AWSTFM to install on any surface using double sided tape or VelcroTM (sold separately). · For use with EN3 Series Relays. · EEP F6-02-02

WIRELESS SOLAR DOOR / WINDOW TRANSMITTER
WDWS2-EN3
EnOcean 902 MHz Wireless Solar Door / Window Transmitter Switch

SPECIFICATIONS
Minimum Illumination: 400 lux hours per day e.g. 100 lux for 4 hours or 200 lux for 2 hours
Start-up Time: Less than 2.5 min @ 400 lux Operating Life in Darkness (after full charge): Min 10 days signs-of-life only Operating Life in Darkness (with backup battery): Min 5 years
Maximum Sensor Gap: 0.16" (4mm) Dimensions : 3.00" L x 0.87"W x 0.59" D (76mm x 22mm x 15mm)
Dimensions (with mounting plate): 3.15" L x 0.94"W x 0.73" D (80mm x 24mm x 19mm) Drill Distance: 2.05" (52mm) Environment: Indoor use only -4 to 140 F (-20 to 60 C) 5 to 93% relative humidity (noncondensing) Approvals: RoHS
Agency Compliance: FCC ID: SZV-STM 320U IC: 5713A-STM 320U

Notes: · Typical range: 100 ft.
· Open area transmission could be farther. Consult factory for more information.
· Only for use with ­EN3 Series relays. · EEP D5-00-01

WIRELESS KEYCARD TRANSMITTER SWITCH
WKC-EN3
EnOcean 902 MHz Wireless Key Card Transmitter Switch
SPECIFICATIONS
Power Supply: Mechanical energy harvesting (power is generated by inserting the card into the key card switch)
Inputs/Outputs: Slot for standard hotel key card: (2.125"W x 3.375" H x 0.034" D) Radio Frequency (RF) transmitter
RF Communications: EnOcean 902 MHz Transmission Range: 80ft. EnOcean Equipment Profile (EEP): F6-04-01
RF Transmission: On key card insertion or removal Installation: Surface mounted on wall (using included mounting screws) Dimensions: 4.72" H x 3.8"W x .43" D (at edge)
Environment: Indoor use only 32° to 131° F (0° to 55° C) 5% to 95% relative humidity (non-condensing)
Agency Compliance: FCC: SZV-PTM330U IC: 5713A-PTM330U
Approvals: RoHS

www.functionaldevices.com/wp-content/uploads/2022/04/B1970_393238.pdf

180

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

WIRELESS DEVICES

WIRELESS OCCUPANCY / VACANCY SENSOR
WVSCM-EN3
EnOcean 902 MHz Wireless Vacancy / Occupancy Sensor, Ceiling Mount
SPECIFICATIONS
RF Transmission Range: 80 ft. Motion Sensing Range: 34 ft. diameter (refer to coverage diagrams)
Startup Charge Times First Motion Transmission / Linking: 5 minutes at 200 lux Motion LED Blink Light / Walk Test Modes: 1.5 hours at 2000 lux
Sustaining Charge Time: 3 hours per 24 hours at 200 lux Time to Full Charge: 25 hours at 200 lux
Operating Life in Total Darkness: 80 hours (after full charge) Minimum Operating Light: 50 lux (for auto-off only)
Motion Transmission Interval: 2 minutes Unoccupied Transmission: 10 and 30 minutes since last motion Dimensions: 6.3" L x 2.35"W x 1.47" D (160 mm x 60 mm x 37 mm) Mounting Height: 7-10 feet recommended Environment: Indoor use only 14° to 104° F (-10° to 40° C) 20 to 95% relative humidity (noncondensing) Approvals: RoHS, R&TTE Agency Compliance: FCC: SZV-STM300U IC: 5713A-STM300U

Notes: · Only for use with ­EN3 Series relays. · EEP A5-07-01
https://www.functionaldevices.com/wp-content/uploads/2022/04/B2104_393249.pdf

WIRELESS OCCUPANCY / VACANCY SENSOR
WVSWM-EN3
EnOcean 902 MHz Wireless Vacancy / Occupancy Sensor, Wall Mount
SPECIFICATIONS
RF Transmission Range: 80 ft. Motion Sensing Range: Up to 100 ft. (refer to coverage diagrams)
Startup Charge Times First Motion Transmission / Linking: 5 minutes at 200 lux Motion LED Blink Light / Walk Test Modes: 1.5 hours at 2000 lux
Sustaining Charge Time: 3 hours per 24 hours at 200 lux Time to Full Charge: 25 hours at 200 lux
Operating Life in Total Darkness: 80 hours (after full charge) Minimum Operating Light: 50 lux (for auto-off only)
Motion Transmission Interval: 2 minutes Unoccupied Transmission: 10 and 30 minutes since last motion Dimensions: 5.83" L x 2.52"W x 1.8" D (148 mm x 64 mm x 45.7 mm) Mounting Height: 6-8 feet recommended Environment: Indoor use only 14° to 104° F (-10° to 40° C) 20 to 95% relative humidity (noncondensing) Approvals: RoHS, R&TTE Agency Compliance: FCC ID: SZV-STM300U IC: 5713A-STM300U

Notes: · Only for use with ­EN3 Series relays. · EEP A5-07-01

WIRELESS DEVICES

(800) 888-5538 | www.functionaldevices.com

181

WIRELESS OCCUPANCY / VACANCY SENSOR
WVSUS-EN3
EnOcean® Enabled Wireless Occupancy / Vacancy Sensor, Ceiling Mount, 902 MHz
SPECIFICATIONS
Solar Supply: Integrated Solar Cells Operational Light Level: 65 lux (6 fc)
Start Up Period < 2 minutes @ 65 lux Battery Supply: CR1632 coin cell battery Battery Life Expectancy: Shelf life as defined by the battery manufacturer
or 5 years, whichever occurs first Radio Frequency: 902 MHz
Antenna: Integrated whip Transmission Range: 24 m (80 ft.) - commercial office spaces(typical),
up 100 m (330ft.) line of sight Telegram Transmission: Vacancy - on heartbeat
Occupancy - Immediately upon motion detection or heartbeat Telegram Heartbeat: 100 seconds min. - 1000 seconds max. Inputs: Teach button, Test button Detection Area: A lens - 450 ft2 at 8 ft. - 800 ft2 at 10 ft B lens - 1,800 ft2 at 8 ft. - 3000 ft2 at 10 ft Operating Temperature: -10°C to 45°C(14°F to 113°F) Storage Temperature: -25°C to 65°C(-13°F to 149°F) Relative Humidity: 5% to 92% RH(non-condensing) Dimensions: 98.0 mm. x 25.5 mm. (3.86" x 1.00") Mounting: Integrated magnets, wire bracket, screws(not supplied), double sided tape (not supplied) Agency Compliance: FCC: 15.231 IC: RSS-210 Origin: Made of US and non- US parts

Notes: · Only for use with ­EN3 Series relays. · EEP A5-07-01

SINGLE SURFACE MOUNT BACKPLATE KIT
AWSTFM
Flush Surface Mount Backplate Kit for WWS2-EN3, White
SPECIFICATIONS
Includes: (2) Switch-mounting screws
For Use With: WWS2-EN3, FDLTS2
Approvals: CE Approved, RoHS Origin: Made of US and non-US parts
Installation Instructions: Mount switch to any surface by using double sided tape or VelcroTM (not included.)

ROCKER SWITCH COVER PLATE
WSTP-W
Wall Switch Plate Replacement, White
SPECIFICATIONS
Approvals: CE, RoHS For use with: WWS-EN3, WWS2-EN3
Origin: Made of US and non-US parts

WIRELESS DEVICES

182

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

MH5503L

MH3803L

MH4404L

ENCLOSURES
Metal & Plastic Enclosures
· NEMA 1 or NEMA 4/4X rated · Various sizes available · Multiple knockouts on many models · Vertically and horizontally stackable · Available with perforated steel or polymetal
sub-panels or track mount · Several cover and door configurations · Grey finish · Blue housings available (consult factory) · Made in the USA · UL Listed

MH3300

MH1210

ENCLOSURES

(800) 888-5538 | www.functionaldevices.com

183

ENCLOSURES

ENCLOSURES

MODEL #

PE6000

·

PE6010

·

PE6020

·

PE6000-N4 ·

PE6010-N4 ·

PE6020-N4 ·

MH1000

·

MH1010

·

MH1020

·

MH1200

·

MH1210

·

MH1220

·

MH2204-N4 ·

MH3100-M1 ·

MH3204-N4 ·

MH3300

·

MH3300K ·

MH3303

·

MH3304

·

MH3303K ·

MH3304K ·

MH3500

·

MH3510

·

MH3520

·

MH3800

·

MH3810

·

MH3820

·

MH3803S ·

MH3803L ·

MH3804S ·

MH3804L ·

MH4400

·

MH4403L ·

MH4404L ·

MH4604S ·

MH5500

·

MH5503L ·

MH5504L ·

MH5800

·

MH5803L ·

MH5804L ·

ENCLOSURE PE6000 PE6000 PE6000
PE6000-N4 PE6000-N4 PE6000-N4 MH1000 MH1000 MH1000 MH1200 MH1200 MH1200
MH3300 MH3300K MH3300 MH3300 MH3300K MH3300K MH3500 MH3500 MH3500 MH3800 MH3800 MH3800 MH3800 MH3800 MH3800 MH3800 MH4400 MH4400 MH4400 MH4600 MH5500 MH5500 MH5500 MH5800 MH5800 MH5800

HOUSING MATERIAL
Plastic Plastic Plastic Plastic Plastic Plastic Metal Metal Metal Metal Metal Metal Metal
Metal
Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal Metal

SUB-PANEL
14 Gauge Steel 14 Gauge Steel
SP3303 # SP3304 ^ SP3303 # SP3304 ^
SP3803S # SP3803L # SP3804S ^ SP3804L ^ SP4403L # SP4404L ^ Perforated Steel SP5503L # SP5504L ^ SP5803L # SP5804L ^

TRACK MOUNT MT4-4 MT212-6 MT4-4 MT212-6 MT4-12 MT212-12 MT4-8 MT212-8 6 Threaded
Studs
MT4-24 MT212-24 MT4-18 MT212-18

NEMA RATING NEMA 1 NEMA 1 NEMA 1 NEMA 4/4X NEMA 4/4X NEMA 4/4X NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 4/4X

COVER / DOOR Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Screw Down Cover Hinge Key Latch Door

HEIGHT 4.28 4.28 4.28 4.28 4.28 4.28 14.50 14.50" 14.50" 8.30" 8.30" 8.30" 9.84

WIDTH 7.00 7.00 7.00 7.00 7.00 7.00 7.70 7.70" 7.70" 7.70" 7.70" 7.70" 7.87

NEMA 1

Screw Down Cover

12.00 12.00

NEMA 4/4X NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1

Hinge Key Latch Door Vertical Lift Screw Down Cover
Vertical Lift Key Latch Vertical Lift Screw Down Cover Vertical Lift Screw Down Cover
Vertical Lift Key Latch Vertical Lift Key Latch Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Reversible Hook Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door Full Hinge Key Latch Door

15.75 12.50 12.50 12.50 12.50 12.50 12.50 24.50 24.50 24.50 24.50 24.50 24.50 24.50 24.50 24.50 24.50 18.00 18.00 18.00 20.00 25.00 25.00 25.00 36.00 36.00 36.00

11.81 12.50 12.50 12.50 12.50 12.50 12.50 10.25 10.25 10.25 12.50 12.50 12.50 12.50 12.50 12.50 12.50 18.00 18.00 18.00 16.15 25.00 25.00 25.00 25.00 25.00 25.00

DEPTH 2.00 2.00 2.00 2.00 2.00 2.00 3.90 3.90" 3.90" 3.90" 3.90" 3.90" 3.98

GAUGE
18 18 18 18 18 18 16

6.00 16

5.91 16 7.00 18 7.00 18 7.00 18 7.00 18 7.00 18 7.00 18 3.90 18 3.90 18 3.90 18 6.50 18 6.50 18 6.50 18 6.50 18 6.50 18 6.50 18 6.50 18 7.00 16 7.00 16 7.00 16 6.72 14 9.50 14 9.50 14 9.50 14 9.50 14 9.50 14 9.50 14

SPEC PAGE 185 185 185 185 185 185 185 185 185 185 185 185 186
186
186 187 187 187 187 187 187 187 187 187 187 187 187 187 187 187 187 188 188 188 188 188 188 188 189 189 189

MH3300 SERIES # Polymetal
11.33"H x 11.40"W
^ Perforated Steel 11.33"H x 11.40"W

MH3800 SERIES
# Polymetal Model S: 19.00"H x 11.75"W Model L: 23.00"H x 11.75"W
^ Perforated Steel Model S: 19.00"H x 11.75"W Model L: 23.00"H x 11.75"W

MH4400 SERIES # Polymetal
16.875"H x 15.75"W
^ Perforated Steel 16.875"H x 15.75"W

MH5500 SERIES # Polymetal
23.00"H x 22.50"W
^ Perforated Steel 23.00"H x 22.50"W

= UL Listed - see data sheet for specific Listing

MH5800 SERIES # Polymetal
34.125"H x 22.50"W
^ Perforated Steel 34.125"H x 22.50"W

184

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

ENCLOSURES

ENCLOSURES

PE6000 Series

Plastic Housing Series, NEMA 1, 0.75" NPT Nipple, 4.28" H x 7.00"W x 2.00" D 7.00"

2.00"

7.00"

2.00"

4.28"

4.28"

SPECIFICATIONS
Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1,
Also available NEMA 4 / 4X

MT212-6 Plastic Snap Track 7.00"
MT4-4 Plastic Snap Track

4.28"

2.00" PE6000 SERIES ASSEMBLIES

Model #

Enclosure Plastic Snap Track NEMA Type

PE6000

PE6000

NEMA 1

PE6010

PE6000 MT4-4 (4.00"W)

NEMA 1

PE6020

PE6000 MT212-6 (2.75"W) NEMA 1

PE6000-N4 PE6000-N4

NEMA 4/4X

PE6010-N4 PE6000-N4 MT4-4 (4.00"W) NEMA 4/4X

PE6020-N4 PE6000-N4 MT212-6 (2.75"W) NEMA 4/4X

Housing Detail: See Housing D in housing guide for dimensions Origin: Made of US and non-US parts

Notes: · Comes with transparent lid. To order with gray
opaque lid, add "-GY" to end of model number.

ENCLOSURES

MH1000 Series
Metal Housing Series, NEMA 1, 14.5" H x 7.7" W x 3.9" D

MH1000 SERIES ASSEMBLIES

7.70" 5.70"

Model #
MH1000

Enclosure
MH1000

Plastic Snap Track

MH1010 MH1000 MT4-12 (4.00"W)

MH1020 MH1000 MT212-12 (2.75"W)

14.50" 11.50" 14.50"

ENCLOSURES

3.90"

7.70"

SPECIFICATIONS
Construction: 18 Gauge Steel Cover Type: Screw Down Cover

Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts

Notes: · Consult factory for custom colors for large orders.

8.30" 5.30" 8.30"

ENCLOSURES
MH1200 Series
Metal Housing, NEMA 1, 8.3" H x 7.7" W x 3.9" D
7.70" 5.70"

MH1200 SERIES ASSEMBLIES

Model #

Enclosure Plastic Snap Track

MH1200 MH1200

MH1210 MH1200 MT4-8 (4.00"W)

MH1220 MH1200 MT212-8 (2.75"W)

3.90"

7.70"

SPECIFICATIONS
Construction: 18 Gauge Steel Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts

Notes: · Consult factory for custom colors for large orders.

(800) 888-5538 | www.functionaldevices.com

185

ENCLOSURES
MH2204-N4
Metal Housing, NEMA 4/4X, 9.84" H x 7.87" W x 3.98" D

3.98"

7.880" 6.420"

7.870"

5.928"
14 Gauge Steel
Sub-Panel

4.500" 9.840" 11.140" 8.580"

4 Brackets .437" x .687" Oblong

SPECIFICATIONS
Construction: 16 Gauge Steel Cover Type: Hinge Key Latch Door

Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts

ENCLOSURES

MH3100-M1
Metal Housing, NEMA 1, 12.00 H x 12.00 W x 6.00 D, Mounting Option 1

1/4"-20 Threaded Stud
1.00" H Max.
8-32 Threaded Stud .375"H

12.00"

6.00"

12.00"

MH3100-M1 ASSEMBLY

Model #

Enclosure Plastic Snap Track

MH3100-M1 * MH3100

6 Threaded Studs

MH3100-M1 + PSMN500A = PSH500A MH3100-M1 + PSMN300A = PSH300A

12.00"

SPECIFICATIONS
Construction: 16 Gauge Steel. Cover Type: Screw Down Cover

Approvals: UL Listed, C-UL, CE, RoHS Origin Made of US and non-US parts

ENCLOSURES
MH3204-N4
Metal Housing, NEMA 4/4X,15.75" H x 11.81" W x 5.91" D

Notes: · To convert panel-mounted power supply to enclosed, simply remove the sub-panel and mount to enclosure with provided screw pack. *

5.910"

11.811" 10.352"

11.811"

9.86"
14 Gauge Steel
Sub-Panel

4 Brackets .437" x .687" Oblong

SPECIFICATIONS
Construction: 16 Gauge Steel Cover Type: Hinge Key Latch Door

Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts

186

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

ENCLOSURES 6.355"
15.75" 16.93" 14.37"

12.75"

ENCLOSURES
MH3300 Series
Metal Housing, NEMA 1, 12.5 H x 12.5 W x 7.0 D
12.50"
12.50"

12.50"

7.00"

MH3300 SERIES ASSEMBLIES

Model # Enclosure

Cover Type

Sub-Panel

MH3300 MH3300 Vertical Lift Screw Down

MH3300K MH3303 MH3304 MH3303K MH3304K

MH3300K MH3300 MH3300 MH3300K MH3300K

Vertical Lift Key Latch Vertical Lift Screw Down Vertical Lift Screw Down
Vertical Lift Key Latch Vertical Lift Key Latch

SP3303 1 SP3304 2 SP3303 1 SP3304 2

1 = Polymetal 11.33" H x 11.40" W

2 = Perforated Steel 11.33" H x 11.40" W

SPECIFICATIONS
Construction: 18 Gauge Steel Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts
ENCLOSURES
MH3500 Series
Metal Housing, NEMA 1, 24.5" H x 10.25" W x 3.9" D

10.25" 8.35"

10.25"

Notes: · Consult factory for custom colors for large orders.

MH3500 SERIES ASSEMBLIES

Model #

Enclosure

Plastic Snap Track

MH3500

MH3500

MH3510

MH3500

MT4-24 (4.00"W)

MH3520

MH3500

MT212-24 (2.75"W)

22.00" 24.50"

ENCLOSURES

3.90"

SPECIFICATIONS
Construction: 18 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door

Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts

Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number.

ENCLOSURES
MH3800 Series
Metal Housing, NEMA 1, 24.5" H x 12.5" W x 6.5" D

10.60"

12.50"

22.00" 24.50"

6.50"

12.50"

MH3800 SERIES ASSEMBLIES

Model #

Enclosure

Plastic Snap Track / Sub-Panel

MH3800

MH3800

MH3800-BL MH3803L-BL MH3803S-BL MH3810

MH3800 MH3800 MH3800 MH3800

SP3803L 1 SP3803S 2 MT4-18 (4.00"W)

MH3820 MH3803S MH3803L MH3804S MH3804L

MH3800 MH3800 MH3800 MH3800 MH3800

MT212-18 (2.75"W) SP3803S 1 SP3803L 1 SP3804S 2 SP3804L 2

Color option
Blue Blue Blue

1 = Polymetal Model S: 19.00" H x 11.75" W Model L: 23.00" H x 11.75" W

2 = Perforated Steel Model S: 19.00" H x 11.75" W Model L: 23.00" H x 11.75" W

SPECIFICATIONS
Construction: 18 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door

Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts

Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number.

(800) 888-5538 | www.functionaldevices.com

187

ENCLOSURES
MH4400 Series
Metal Housing, NEMA 1, 18.0" H x 18.0" W x 7.0" D

18.00"

18.00"

18.00"

13.50"

16.00"

MH4400 SERIES ASSEMBLIES

Model #

Enclosure

Sub-Panel

MH4400 MH4403L MH4404L

MH4400 MH4400 MH4400

SP4403L 1 SP4404L 2

1 = Polymetal 16.875" H x 15.75" W

2 = Perforated Steel 16.875" H x 15.75" W

7.125"

SPECIFICATIONS
Construction: 16 Gauge Steel Cover Type: Full Hinge Key Latch Door

Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts

Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number.

ENCLOSURES
MH4604S
Metal Housing, NEMA 1, 20.0" H x 16.15" W x 6.72" D with SP4604S Sub-Panel

16.15"

16.15"

20.00"

17.50"

ENCLOSURES

14.25"

6.72"

SPECIFICATIONS
Construction: 14 Gauge Steel Cover Type: Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS

Subpanel: Perforated Steel (14.87" x 14.62") Origin: Made of US and non-US parts

Notes: · Consult factory for custom colors for large orders.

ENCLOSURES
MH5500 Series
Metal Housing, NEMA 1, 25.0" H x 25.0" W x 9.5" D

25.00"

25.00"

25.00"

22.50"

9.50"

23.10"
SPECIFICATIONS
Construction: 14 Gauge Steel Cover Type: Full Hinge Key Latch Door Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts

MH5500 SERIES ASSEMBLIES

Model # MH5500 MH5503L MH5504L

Enclosure MH5500 MH5500 MH5500

Sub-Panel
SP5503L 1 SP5504L 2

1 = Polymetal

2 = Perforated Steel

23.00" H x 22.50" W

23.00" H x 22.50" W

Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number.

188

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

ENCLOSURES
MH5800 Series
Metal Housing, NEMA 1, 36.0" H x 25.0" W x 9.5" D

25.00"

25.00"

36.00"

33.50"

9.50"

23.10"
SPECIFICATIONS
Construction: 14 Gauge Steel Cover Type: Full Hinge Key Latch Door Approvals: UL Listed, C-UL, CE, RoHS Origin: Made of US and non-US parts

MH5800 SERIES ASSEMBLIES

Model #

Enclosure

Sub-Panel

MH5800 MH5803L MH5804L

MH5800 MH5800 MH5800

SP5803L 1 SP5804L 2

1 = Polymetal

2 = Perforated Steel

34.125" H x 22.50" W

34.125" H x 22.50" W

Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number.

ENCLOSURES

(800) 888-5538 | www.functionaldevices.com

189

SP3303

MT4-6

ADIN35 & ADIN35ES

SP3804S

ACCESSORIES
Sub-Panels
Two types of sub-panel material are available: polymetal and perforated steel. Both the polymetal and perforated steel sub-panels are Plenum Rated and designed to mount in "MH" metal housing models. The mounting holes are pre-drilled and ready to install. Sub-panels can be ordered pre-installed in your choice of "MH" enclosure. See general specifications of pre-assembled enclosure models on page 77.
Replacement Parts
Replacement parts are available for several products including remote sensors, socket relays, and more.

Mounting Supplies
Mounting options include plastic track for snap-mounting circuit boards. One style of track can be mounted to the back surface of any cabinet and is available in 4.00" or 2.75" widths. Another style of track, AdapTrack®, snaps onto any of the three most popular DIN rails. In turn, it can accomodate a 4.00" wide circuit board. Perforated DIN rail and end stops are also available.

190

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

ACCESSORIES

ACCESSORIES

SUB-PANELS

MODEL # SP3303 SP3304 SP3803S SP3803L SP3804S SP3804L SP4403L SP4404L SP5503L SP5504L SP5803L SP5804L

USE WITH ENCLOSURE MH3300 or MH3300K MH3300 or MH3300K
MH3800 MH3800 MH3800 MH3800 MH4400 MH4400 MH5500 MH5500 MH5800 MH5800

MOUNTING SUPPLIES

MODEL #

MT212-2

·

MT212-4

·

MT212-6

·

MT212-8

·

MT212-12

·

MT212-18

·

MT212-24

·

MT212-48

·

MT4-2

·

MT4-4

·

MT4-6

·

MT4-8

·

MT4-10

·

MT4-12

·

MT4-18

·

MT4-24

·

MT4-48

·

AT4-2

·

AT4-6

·

AT4-12

·

AT4-24

·

AT4-48

·

ADIN35

WIDTH 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 35 mm

MATERIAL Polymetal Perforated Steel Polymetal Polymetal Perforated Steel Perforated Steel Polymetal Perforated Steel Polymetal Perforated Steel Polymetal Perforated Steel
LENGTH 2.00" 4.00" 6.00" 8.00" 12.00" 18.00" 24.00" 48.00" 2.00" 4.00" 6.00" 8.00" 10.00" 12.00" 18.00" 24.00" 48.00" 2.00" 6.00" 12.00" 24.00" 48.00"
7.5 mm

HEIGHT 11.330 11.330 19.000 23.000 19.000 23.000 16.875 16.875 23.000 23.000 34.125 34.125

WIDTH 11.400 11.400 11.750 11.750 11.750 11.750 15.750 15.750 22.500 22.500 22.500 22.500

THICKNESS .130 .250 .130 .130 .250 .250 .130 .250 .130 .250 .130 .250

MOUNTING AREA 129.16 square inches 129.16 square inches 223.25 square inches 270.25 square inches 223.25 square inches 270.25 square inches 265.78 square inches 265.78 square inches 517.50 square inches 517.50 square inches 767.81 square inches 767.81 square inches

SPEC PAGE 192 192 192 193 193 193 194 194 194 195 195 196

TRACK TYPE Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track Screw mounted snap-in track
AdapTrack® for DIN rail AdapTrack® for DIN rail AdapTrack® for DIN rail AdapTrack® for DIN rail AdapTrack® for DIN rail
Perforated DIN rail

DISTANCE BETWEEN HOLE CENTERS 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center 2.00" Center to Center
3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 3 Most Common for AT4 Series # 3 Most Common for AT4 Series #
25 mm Center to Center

SPEC PAGE 196 196 196 196 196 196 196 196 197 197 197 197 197 197 197 197 197 197 197 197 197 197 197

REPLACEMENT & MISCELLANEOUS PARTS

MODEL # ADIN35ES APS53-TC APSB-TC AR24D ARL1C AXG AXGT AXK AXKT DS80625 KEYSET MKL-1 MKL-2 MKL-3 MKL-4 TS-AN TS-BC

DESCRIPTION Pair of End Stops for 35mm DIN Rail Primary voltage terminal cover One terminal cover and two clips Replacement relays (3-pack) Replacement relays (3-pack) Split ring remote current sensor assembly (Wire Output) Split ring remote current sensor assembly (Terminal Output) Remote mini current sensor assembly (Wire Output) Remote mini current sensor assembly (Terminal Output) No. 8 x 5/8 Self-Tapping Drill Screws One set of 2 keys Locking key latch assembly Locking key-hook latch assembly Metal locking key latch assembly Coin locking key latch assembly Pluggable terminal strips Replacement pluggable terminal strips

FOR USE WITH MODEL(S) ADIN35
Functional Devices 300 VA and 500 VA power supplies PSB100AB10, PSB40AB10 RIBR24D, RIBR24SD
RIBRL1C, RIBRL1S, RIBRXLCA, RIBRXLCF, RIBRXLSA RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF
Functional Devices polymetal sub-panels Functional Devices key latch metal enclosures Functional Devices metal enclosures except MH3300K Functional Devices MH3300K metal enclosures Functional Devices metal enclosures except MH3300K Functional Devices metal enclosures except MH3300K
RIBAN12C, RIBAN24C RIBTW2401B-BC, RIBTW2402B-BC

SPEC PAGE 198 198 198 198 199 199 199 199 200 200 200 200 200 200 200 200

= UL Component Recognized - see data sheet for specific Listing

# = 32 mm x 15 mm asymmetrical DIN rail EN50035; 35 mm x 7.5 mm symmetrical DIN rail EN50022; 22.4 mm x 6.9 mm symmetrical NEMA A Series rail

(800) 888-5538 | www.functionaldevices.com

191

ACCESSORIES

SUB-PANEL
SP3303
Polymetal Sub-Panel, 11.33" H x 11.40" W x 0.13" Thick, For use with MH3300 or MH3300K
11.4000"

11.3300" 10.2050"

2.5000"

6.4000"

2.5000"

.5625"
SPECIFICATIONS
Mounting Area: 129.16 square Approvals: Plenum Rated Origin: Made of US and non-US parts

Enclosure Assemblies: MH3303 MH3300 Enclosure with SP3303
Sub-Panel pre-mounted

MH3303K MH3300K Enclosure with SP3303 Sub-Panel pre-mounted

SUB-PANEL
SP3304
Perforated Steel Sub-Panel, 11.33" H x 11.40"W x 0.25"Thick, For use with MH3300 or MH3300K
11.4000"

11.3300" 10.2050"

2.5000"

6.4000"

2.5000"

.5625"
SPECIFICATIONS
Mounting Area: 129.16 square Approvals: Plenum Rated Origin: Made of US and non-US parts

Enclosure Assemblies: MH3304 MH3300 Enclosure with SP3304 Sub-Panel pre-mounted

MH3304K MH3300K Enclosure with SP3304 Sub-Panel pre-mounted

SUB-PANEL
SP3803S
Polymetal Sub-Panel, 19.00" H x 11.75" W x 0.13" Thick, For use with MH3800
11.7500"

9.0000"

10.7500"

.5000"

19.0000"

9.0000"

8.5000"

.5000"
SPECIFICATIONS

Mounting Area: 223.25 square

Enclosure Assemblies: MH3803S

Approvals: Plenum Rated

MH3800 Enclosure with SP3803S

Origin: Made of US and non-US parts

Sub-Panel pre-mounted

192

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

ACCESSORIES

SUB-PANEL
SP3803L
Polymetal Sub-Panel, 23.00" H x 11.75" W x 0.13" Thick, For use with MH3800
11.7500"

4.5000"

10.7500"

.5000"

9.000"

23.000"

9.000"

8.5000"

.5000"

SPECIFICATIONS

Mounting Area: 270.25 square

Enclosure Assemblies: MH3803L

Approvals: Plenum Rated

MH3800 Enclosure with SP3803L

Origin: Made of US and non-US parts

Sub-Panel pre-mounted

SUB-PANEL

SP3804S
Perforated Steel Sub-Panel, 19.00" H x 11.75"W x 0.25"Thick, For use with MH3800
11.7500"

9.0000"

10.7500"

.5000"

19.0000"

9.0000"

8.5000"

.5000"

SPECIFICATIONS

Mounting Area: 223.25 square

Enclosure Assemblies: MH3804S

Approvals: Plenum Rated

MH3800 Enclosure with SP3804S

Origins: Made of US and non-US parts

Sub-Panel pre-mounted

SUB-PANEL
SP3804L
Perforated Steel Sub-Panel, 23.00" H x 11.75"W x 0.25"Thick, For use with MH3800
11.7500"

4.5000"

10.7500"

.5000"

9.000"

23.000"

9.000"

8.5000"

.5000"

SPECIFICATIONS

Mounting Area: 270.25 square

Enclosure Assemblies: MH3804L

Approvals: Plenum Rated

MH3800 Enclosure with SP3304L

Origin: Made of US and non-US parts

Sub-Panel pre-mounted

(800) 888-5538 | www.functionaldevices.com

193

ACCESSORIES

SUB-PANEL
SP4403L
Polymetal Sub-Panel, 16.875" H x 15.750" W x 0.130" Thick, For use with MH4400
15.7500"

14.3750"

.7500"

16.8750" 15.3750"

.7500"

SPECIFICATIONS

Mounting Area: 265.78 square

Enclosure Assemblies: MH4403L

Approvals: Plenum Rated

MH4400 Enclosure with SP4403L

Origin: Made of US and non-US parts

Sub-Panel pre-mounted

SUB-PANEL
SP4404L
Perforated Steel Sub-Panel, 16.875" H x 15.750"W x 0.25"Thick, For use with MH4400
15.7500"

14.3750"

.7500"

16.8750" 15.3750"

.7500"

SPECIFICATIONS

Mounting Area: 265.78 square

Enclosure Assemblies: MH4404L

Approvals: Plenum Rated

MH4400 Enclosure with SP4404L

Origin: Made of US and non-US parts

Sub-Panel pre-mounted

SUB-PANEL
SP5503L
Polymetal Sub-Panel, 23.00" H x 22.50" W x 0.13" Thick, For use with MH5500

22.5000"

10.7500"

10.5000"

10.5000"

.7500"

10.7500"

ACCESSORIES
23.0000"

.7500"

SPECIFICATIONS

Mounting Area: 517.50 square

Enclosure Assemblies: MH5503L

Approvals: Plenum Rated

MH5500 Enclosure with SP5503L

Origin: Made of US and non-US parts

Sub-Panel pre-mounted

194

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

SUB-PANEL
SP5504L
Perforated Steel Sub-Panel, 23.00" H x 22.50"W x 0.25"Thick, For use with MH5500
22.5000"

10.7500"

10.5000"

10.5000"

.7500"

23.0000"

10.7500"

.7500"

SPECIFICATIONS

Mounting Area: 517.50 square

Enclosure Assemblies: MH5504L

Approvals: Plenum Rated

MH5500 Enclosure with SP5504L

Origin: Made of US and non-US parts

Sub-Panel pre-mounted

SUB-PANEL
SP5803L
Polymetal Sub-Panel, 34.00" H x 22.50" W x 0.13" Thick, For use with MH5800
22.5000"

10.5000"

10.5000"

.7500"

16.2500"

34.1250"

16.2500"

.7500"

SPECIFICATIONS

Mounting Area: 767.81 square

Enclosure Assemblies: MH5803L

Approvals: Plenum Rated

MH5800 Enclosure with SP5803L

Origin: Made of US and non-US parts

Sub-Panel pre-mounted

ACCESSORIES

(800) 888-5538 | www.functionaldevices.com

195

SUB-PANEL
SP5804L
Perforated Steel Sub-Panel, 34.00" H x 22.50"W x 0.25"Thick, For use with MH5800
22.5000"

10.5000"

10.5000"

.7500"

16.2500"

34.1250"

16.2500"

.7500"

SPECIFICATIONS

Mounting Area: 767.81 square

Enclosure Assemblies: MH5804L

Approvals: Plenum Rated

MH5800 Enclosure with SP5804L

Origin: Made of US and non-US parts

Sub-Panel pre-mounted

MOUNTING TRACK
MT212 Series
2.75 Wide Mounting Track for Relays, Current Sensors, and Power Supplies
Length

2.75"

2.00"

SPECIFICATIONS
Flame Rated: 94-5V Approvals: UL Component Recognized, USA & Canada CE, RoHS Mounting: MT212 Series track can be screw-mounted to any flat surface to provide mounting for 2.75 wide track-mountable relays, current sensors, or power supplies. Origin: Made of US and non-US parts

MT212 SERIES SELECTION GUIDE

Model #

Width

Length

Distance Between Hole Centers

MT212-2

2.75

2.00

2.00 Center to Center

MT212-4

2.75

4.00

2.00 Center to Center

MT212-6

2.75

6.00

2.00 Center to Center

MT212-8

2.75

8.00

2.00 Center to Center

MT212-12

2.75

12.00

2.00 Center to Center

MT212-18

2.75

18.00

2.00 Center to Center

MT212-24

2.75

24.00

2.00 Center to Center

MT212-48

2.75

48.00

2.00 Center to Center

ACCESSORIES

196

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

4.00"

MOUNTING TRACK
MT4 Series
4.00 Wide Mounting Track for Relays, Current Sensors, and Power Supplies Length
2.00"
SPECIFICATIONS
Flame Rated: 94-5V Approvals: UL Component Recognized, USA & Canada CE, RoHS Mounting: MT4 Series track can be screw-mounted to any flat surface to provide mounting for 4.00 wide track-mountable relays, current sensors, or power supplies. Origin: Made of US and non-US parts
MOUNTING TRACK
AT4 Series
4.00 Wide AdapTrack® for Relays, Current Sensors, and Power Supplies
Length

MT4 SERIES SELECTION GUIDE

Model #

Width Length Distance Between Hole Centers

MT4-2

4.00

2.00

2.00 Center to Center

MT4-4

4.00

4.00

2.00 Center to Center

MT4-6

4.00

6.00

2.00 Center to Center

MT4-8

4.00

8.00

2.00 Center to Center

MT4-10

4.00

10.00

2.00" Center to Center

MT4-12

4.00

12.00

2.00 Center to Center

MT4-18

4.00

18.00

2.00 Center to Center

MT4-24

4.00

24.00

2.00 Center to Center

MT4-48

4.00

48.00

2.00 Center to Center

4.00"

SPECIFICATIONS
Flame Rated: 94-5V DIN Rail Sizes: 32 mm x 15 mm asymmetrical DIN rail EN50035
35 mm x 7.5 mm symmetrical DIN rail EN50022 22.4 mm x 6.9 mm symmetrical NEMA A Series rail Approvals: UL Component Recognized, USA & Canada CE, RoHS Mounting: AT4 Series AdapTrack® snaps onto the three most common DIN rail sizes to provide mounting for 4.00 wide track-mountable relays, current sensors, or power supplies. Origin: Made of US and non-US parts
MOUNTING TRACK
ADIN35
DIN Rail Perforated 35mm x 7.5mm x 1m

Model # AT4-2 AT4-6 AT4-12 AT4-24 AT4-48

AT4 SERIES SELECTION GUIDE

Width Length

DIN Rail Sizes

4.00

2.00 3 Most Common (see general specs to the left)

4.00

6.00 3 Most Common (see general specs to the left)

4.00

12.00 3 Most Common (see general specs to the left)

4.00

24.00 3 Most Common (see general specs to the left)

4.00

48.00 3 Most Common (see general specs to the left)

ACCESSORIES

SPECIFICATIONS
Approvals: CE Approved, RoHS, EN60715:2001 Materials: Steel galvanized and passivated with a thick layer

Pair of end stops sold separately.

(800) 888-5538 | www.functionaldevices.com

197

MOUNTING TRACK
ADIN35ES
End Stops for 35mm DIN Rail

SPECIFICATIONS
Approvals: CE Approved, RoHS, EN60715:2001 Materials: Polyamide 6.6 Dimensions: 32mm x 28mm x 8mm
REPLACEMENT
APS53-TC
Terminal Cover for PSH500A and PSH300A
SPECIFICATIONS
Includes: (2) Self-Tapping Drill Screws for Installation
For Use With: PSMN300A, PSMN300A-IC, PSMN500A, PSMN500A-IC, PSH300A, PSH300A-IC, PSH500A, PSH500A-IC
Origin: Made of US and non-US parts
REPLACEMENT
APSB-TC
1 Terminal Cover and 2 Clips for PSB 4up-Terminal
SPECIFICATIONS
*Only For Only for Use With: PSB100AB10, PSB40AB10 Installation Instructions: Remove end screws. Position one clip on each outside screw. Insert screws through hole in clip. Snap cover onto clips. Origin: Made of US and non-US parts
REPLACEMENT
AR24D
Pluggable Relays (3-pack), Replacement for RIBR24 Series
SPECIFICATIONS
Dimensions: 1.125" x 0.5" x 0.75": (One relay) 4.25" x 0.625" x 0.875" (Package of 3)
*Only For Only for Use With: RIBR24D, RIBR24SD Purpose: Replacement relay
Approvals: CE Approved, RoHS Origin: Made of US and non-US parts
REPLACEMENT
ARL1C
Pluggable Relays (3-pack), Replacement for RIBRL & RIBRX Series
SRPEEPCLIAFICCEAMTIEONNTS
Dimensions: 1.125" x 0.5" x 1: (One relay) 4.25" x 0.625" x 1.125" (Package of 3)
*Only For Only for Use With: RIBRL1C, RIBRL1S, RIBRXLCF, RIBRXLCA, RIBRXLSA Purpose: Replacement relay
Approvals: CE Approved, RoHS Origin: Made of US and non-US parts

ACCESSORIES

198

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

REPLACEMENT
AXG
Split Core Remote with Wires, Replacement for Any Damaged or Lost Sensor, for Use with Models Listed on Data Sheet
SPECIFICATIONS
Dimensions: (Inside) .52 x .52 (Outside) 2.52 x 2.00 x 1.75
*Only For Only for Use With: RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF Can replace any damaged or lost sensor.
Purpose: For use with the models listed above. Origin: Made of US and non-US parts
REPLACEMENT
AXGT
Split Core Remote with Terminals, Replacement for Any Damaged or Lost Sensor, for Use with Models Listed on Data Sheet
SPECIFICATIONS
Dimensions: (Inside) .52 x .52 (Outside) 2.52 x 2.00 x 1.75
*Only For Only for Use With: RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF Can replace any damaged or lost sensor.
Purpose: For use with the models listed above. Origin: Made of US and non-US parts
REPLACEMENT
AXK
Solid Core Remote with Wires, Replacement for Any Damaged or Lost Sensor, for Use with Models Listed on Data Sheet
SPECIFICATIONS
Dimensions: (Inside Diameter) .50 (Outside) 1.86 x 1.46 x 1.50
*Only For Only for Use With: RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF Can replace any damaged or lost sensor.
Purpose: For use with the models listed above. Origin: Made of US and non-US parts
REPLACEMENT
AXKT
Solid Core Remote with Terminals, Replacement for Any Damaged or Lost Sensor, for Use with Models Listed on Data Sheet
SPECIFICATIONS
Dimensions: (Inside Diameter) .50 (Outside) 2.05 x 1.46 x 1.50
*Only For Only for Use With: RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF Can replace any damaged or lost sensor.
Purpose: For use with the models listed above. Origin: Made of US and non-US parts
(800) 888-5538 | www.functionaldevices.com

199

ACCESSORIES

SCREW SET
DS80625
Number 8 Self-Tapping Drill Screws
SPECIFICATIONS
Size: No. 8 x 5/8 For Use With: All polymetal sub-panels Advantages: Self-tapping, eliminates mushrooming
Weight: 0.004 Origin: Made of US and non-US parts
LOCK ASSEMBLY
MKL-1
Locking Key Latch Assembly for Use with All Metal Enclosures Except MH3300K
SPECIFICATIONS
Origin: Made of US and non-US parts
LOCK ASSEMBLY
MKL-3
Metal Locking Key Latch Assembly for Use with All Metal Enclosures Except MH3300K
SPECIFICATIONS
Origin: Made of US and non-US parts
REPLACEMENT
TS-AN
Replacement Pluggable Terminal Strips for RIBAN Series
SPECIFICATIONS
*Only For Use With: RIBAN12C, RIBAN24C Installation Instructions: Plug the terminal
strips into the headers found on the RIBAN Series product. Origin: Made of US and non-US parts

KEY SET
KEYSET
Set of Two Metal Enclosure Replacement Keys
SPECIFICATIONS
Quantity: Two keys and one ring per set For Use With: Any of the key-lock enclosures Advantages: Works with any Functional
Devices, Inc. key-lock enclosures Origin: Made of US and non-US parts
LOCK ASSEMBLY
MKL-2
Locking Key-Hook Latch Assembly for Use with MH3300K
SPECIFICATIONS
Origin: Made of US and non-US parts
LOCK ASSEMBLY
MKL-4
Coin Locking Key Latch Assembly for Use with All Metal Enclosures Except MH3300K
SPECIFICATIONS
Origin: Made of US and non-US parts
REPLACEMENT
TS-BC
Replacement Pluggable Terminal Strips for RIBTW240*B-BC Series; one 2-up and one 5-up
SPECIFICATIONS
*Only For Use With: RIBTW2401B-BC, RIBTW2402B-BC
Approvals: CE, RoHS Installation Instructions: Plug the terminal strips
into the headers found on the RIBTW240*B-BC models.

ACCESSORIES

200

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

HOUSING GUIDE

0.15"

2.80" 2.55"
1.70" 0.765" 0.50" NPT

0.2" 0.25"

2.125"
1.50" 0.55"

4.31" 3.31"

1.89" 2.39"

0.50" or 0.75 NPT

2.54"
1.81" 0.68"

HOUSING A

HOUSING B

4.00"

.20"

.20"

0.2"

.20"

.20"

.44" .56"
0.50" NPT

4.00" .44" .56"
2.00" 1.81"
1.00"

2.00" 0.84"

0.86" 4.28"

7.00"

0.81"
2.00" 0.75" NPT

HOUSING C

red ("-rd") and NEMA 4 ("-N4") HOUSINGS Available.
See our website for details.
HOUSING D

1.09"

4.17" .20"

1.68" 1.40"

5.30" .20"

1.18"

4.58"

5.634" 4.9"

1.06" 1.68" .20"

4.00"
5.15" .20"

1.00" 1.32"

5.50"

1.28"

HOUSING E

HOUSING F

HOUSING G

Circuit Board H
W D1
D2 Track 680957
HOUSING H

2.75" 2.00"

1.025"

2.43"

2.85"

2.90"

1.50"

2.36"

1.05"

HOUSING I

with Retaining Clip for 1/2 Knockout
HOUSING J

3.88" .78" 2.76"
HOUSING K

(800) 888-5538 | www.functionaldevices.com

201

INDEX & RERENCES

INDEX

ADIN35

197 MH4404L

188 PSH100AWB10

112 PULS-PIM60-241

108

RIBHX24BF

97

ADIN35ES

198 MH4604S

188 PSH200A

114 PULS-PIM60-245

108

RIBL12B

65

APS53-TC

198 MH5500

188 PSH200AB10-LVC

118 PULS-PIM90-241

108

RIBL12BM

65

APSB-TC

198 MH5503L

188 PSH200A-LVC

116 PULS-PIM90-245

108

RIBL12SB

65

AR24D

198 MH5504L

188 PSH24DWB10

123

PULS-PIM90-245-L1 108

RIBL12SBM

65

ARL1C

198 MH5800

189 PSH2C2RB10

172 RIB013P

50

RIBL1C-DC

25

AT4-12

197 MH5803L

189 PSH2C2RB10-L

173 RIB01BDC

79

RIBL24B

66

AT4-2

197 MH5804L

189 PSH2RB10

169 RIB01P

49

RIBL24BM

66

AT4-24

197 MHP3903100A100AB10 121 PSH300A

114 RIB01P30

53

RIBL24SB

66

AT4-48

197 MHP3903100AB10 120 PSH300AB10-LVC

118 RIB01P30-S

53

RIBL24SBM

66

AT4-6

197 MHP3904100A100AB10 121 PSH300A-LVC

115 RIB01SBCDC

80

RIBL3C

23

AWSTFM

182 MHP3904100AB10 120 PSH40A

110 RIB01SBDC

80

RIBL4C

23

AXG

199 MHP4604100A100AB10 122 PSH40AB10

110 RIB023P

50

RIBLB

133

AXGT

199 MHP4604100AB10 121 PSH40AB10-EXT2

111 RIB02BDC

79

RIBLB-2

137

AXK

199 MKL-1

200 PSH40AW

110 RIB02P

49

RIBLB-4

137

AXKT

199 MKL-2

200 PSH40AWB10

110 RIB02P30

53

RIBLB-6

137

CT-025A1-333

163 MKL-3

200 PSH500A

113 RIB02SBCDC

80

RIBM013PN

62

CT-050A1-333

163 MKL-4

200 PSH500AB10-LVC

117 RIB02SBDC

80

RIBM013PNDC

83

CT-05A0-333

163 MOD1-07-33MV

163 PSH500A-LVC

115 RIB043P

51

RIBM01ZNDC

83

CT-100A1-333

163 MOD2-07-33MV

163 PSH600-UPS (Kit)

169 RIB04P

50

RIBM023PN

62

CT-100A2-333

163 MOD3-07-33MV

163 PSH600-UPS-BC (Kit) 174 RIB12C-FA

75

RIBM02ZNDC

83

CT-100A4-333

163 MT212-12

196 PSH600-UPS-STAT (Kit) 171 RIB12P

52

RIBM043PN

63

CT-200A4-333

163 MT212-18

196 PSH75A

111 RIB12P30

52

RIBM043PN-HD

63

CT-400A4-333

163 MT212-2

196 PSH75A75A

112 RIB12S-FA

75

RIBM12C

37

CT-600A4-333

163 MT212-24

196 PSH75A75AB10

112 RIB21CDC

79

RIBM12S

37

CTRL-PS

120 MT212-4

196 PSH75A75AW

112 RIB2401B

47

RIBM2401B

59

CTS-05A20-333

163 MT212-48

196 PSH75A75AWB10

112 RIB2401B2G

49

RIBM2401D

38

CTS-100A55-333

163 MT212-6

196 PSH75AB10

111 RIB2401C

26

RIBM2401SB

59

CTS-30A20-333

163 MT212-8

196 PSH75AW

111 RIB2401D

24

RIBM2401SBC

60

CTS-60A35-333

163 MT4-10

197 PSH75AWB10

111 RIB2401SB

47

RIBM2402B

59

DS80625

200 MT4-12

197 PSH850-UPS-STAT (Kit) 173 RIB2401SBC

48

RIBM2402D

38

KEYSET

200 MT4-18

197 PSM19A24DAS

125 RIB2402B

47

RIBM2402SB

59

MH1000

185 MT4-2

197 PSM20A12DAS

124 RIB2402B2G

49

RIBM2402SBC

60

MH1010

185 MT4-24

197 PSM24A24DAS

125 RIB2402D

24

RIBM243PN

61

MH1020

185 MT4-4

197 PSM2RB10

170 RIB2402SB

47

RIBM24C

37

MH1200

185 MT4-48

197 PSMN01SB10

166 RIB2402SBC

48

RIBM24S

37

MH1210

185 MT4-6

197 PSMN01SB4

166 RIB2421B

48

RIBM24ZL

61

MH1220

185 MT4-8

197 PSMN200A

114 RIB2421C

26

RIBM24ZN

60

MH2204-N4

186 PE6000

185 PSMN24DA

124 RIB2421SB

48

RIBME2401B

73

MH3100-M1

186 PE6000-N4

185 PSMN24DAS

124 RIB243P

51

RIBME2402B

73

MH3204-N4

186 PE6010

185 PSMN24SB10

166 RIB24C-FA

75

RIBMH1C

38

MH3300

187 PE6010-N4

185 PSMN24SB4

166 RIB24P

52

RIBMH1S

39

MH3300K

187 PE6020

185 PSMN2C2RB10

172 RIB24P30

52

RIBMH1SC

40

MH3303

187 PE6020-N4

185 PSMN2RB10

170 RIB24P-FA

76

RIBMH1SM-250

40

MH3303K

187 PSB100AB10

109 PSMN300A

114 RIB24S-FA

75

RIBMH2C

39

MH3304

187 PSB40AB10

109 PSMN40A

110 RIB24Z

51

RIBMN12C

41

MH3304K

187 PSC100AB10

109 PSMN40A24DS

125 RIB347P

50

RIBMN12C-FA

77

MH3500

187 PSC40AB10

109 PSMN40AS

110 RIBAN12C

36

RIBMN12S

41

MH3510

187 PSH100A

112 PSMN500A

113 RIBAN24C

36

RIBMN12S-FA

77

MH3520

187 PSH100A100A

113 PSMS1

167 RIBD01BDC

81

RIBMN2401D

43

MH3800

187 PSH100A100AB10

113 PSP24DA

122 RIBD02BDC

81

RIBMN24C

41

MH3803L

187 PSH100A100AB10-DC 126 PSPT2RB10

166 RIBD2421C

27

RIBMN24C-4T

42

MH3803S

187 PSH100A100AW

113 PSPT2RB4

166 RIBH1C

22

RIBMN24C-FA

77

MH3804L

187 PSH100A100AWB10 113 PSPW2RB10

166 RIBH1CW

30

RIBMN24Q2C

139

MH3804S

187 PSH100A24DWB10 123 PSPW2RB4

166 RIBH1S

23

RIBMN24Q3C

139

MH3810

187 PSH100AB10

112 PULS-ML15-241

108 RIBH1SC

25

RIBMN24Q4C

140

MH3820

187 PSH100AB10-DC

126 PULS-PIC120-241D 108 RIBH1SM-250

24

RIBMN24Q4C-PX

140

MH4400

188 PSH100AB10-EXT2 111 PULS-PIC240-241D 108 RIBH2C

22

RIBMN24S

41

MH4403L

188 PSH100AW

112 PULS-PIM36-241

108 RIBHX24BA

97

RIBMN24S-4T

42

202

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

INDEX & RERENCES

INDEX

RIBMN24S-FA

77

RIBT243B

57 RIBX243PF

103 RIBXLCRA

98

TR20VA004

129

RIBMN24S-J

42

RIBT243P

58 RIBX243PV

103 RIBXLCRF

98

TR20VA007

129

RIBMN24ZL

61

RIBT24B

54 RIBX24BA

100 RIBXLCV

98

TR240VA001

130

RIBMNA1D0

141

RIBT24B-FA

76 RIBX24BF

100 RIBXLSA

99

TR300VA002

130

RIBMNH1C

43

RIBT24P

57 RIBX24BV

100 RIBXLSEA

99

TR375VA001

130

RIBMNH1S

44

RIBT24SB

54 RIBX24SBA

100 RIBXLSEV

99

TR40VA001

129

RIBMNH1SM-250

44

RIBT24Z

58 RIBX24SBF

100 RIBXLSF

99

TR40VA001US

127

RIBMNLB

132

RIBTD2401B

56 RIBX24SBV

100 RIBXLSJA

99

TR40VA002

129

RIBMNLB-1

136

RIBTE01B

69 RIBXA

95 RIBXLSJF

99

TR40VA002US

127

RIBMNLB-2

135

RIBTE01P

72 RIBXF

95 RIBXLSRA

99

TR40VA003

129

RIBMNLB-2NO

138

RIBTE01P-S

73 RIBXG21A

89 RIBXLSRF

99

TR40VA004

129

RIBMNLB-4

135

RIBTE01SB

70 RIBXG21F

89 RIBXLSV

99

TR40VA013

129

RIBMNLB-4NO

138

RIBTE02B

69 RIBXG21TA

89 RIBXRA

95

TR40VA015

129

RIBMNLB-6

135

RIBTE02P

72 RIBXG21TF

89 RIBXRF

95

TR40VA022

129

RIBMNLB-6NO

138

RIBTE02P-S

73 RIBXG420-100

93 RIBXV

95

TR40VA040

129

RIBMNU1C

43

RIBTE02SB

71 RIBXG420-20

93 ROPE16-040A-07MV 163

TR50VA001

129

RIBMNU1S

44

RIBTE24B

68 RIBXG420-50

93 ROPE24-060A-07MV 163

TR50VA001US

127

RIBMNU1SM-250

44

RIBTE24P

71 RIBXGA

88 ROPE36-080A-07MV 163

TR50VA002

129

RIBMNW24B-BCAI 150

RIBTE24SB

70 RIBXGA-SCAL

88 ROPE48-100A-07MV 163

TR50VA003

129

RIBMNW24B-MBAI 156

RIBTELC

68 RIBXGF

88 SIB02S

167

TR50VA004

129

RIBMNWD12-BC

154

RIBTELS

68 RIBXGFL

88 SIB04S

167

TR50VA005

129

RIBMNWD12-BCDI 153

RIBTH1C

29 RIBXGHA

87 SIB05S

168

TR50VA005US

127

RIBMNWLB-7-BC

134

RIBTH1S

30 RIBXGHF

87 SIBLS

168

TR50VA006

129

RIBMNWX2401B-BC 146

RIBTH1SC

31 RIBXGHTA

87 SP3303

192

TR50VA007

129

RIBMNWX2402B-BC 148

RIBTH2C

29 RIBXGHTF

87 SP3304

192

TR50VA008

129

RIBMU1C

38

RIBTPM413-BC-KIT 162 RIBXGNTA

90 SP3803L

193

TR50VA009

129

RIBMU1S

39

RIBTU1C

29 RIBXGNTF

90 SP3803S

192

TR50VA014

129

RIBMU1SC

40

RIBTU1S

30 RIBXGNTF-125

90 SP3804L

193

TR50VA015

129

RIBMU1SM-250

40

RIBTU1SC

31 RIBXGT420-RMS

94 SP3804S

193

TR50VA016

129

RIBMU2C

39

RIBTU2C

29 RIBXGTA

88 SP4403L

194

TR50VA017

129

RIBMW24B-44-BC

155

RIBTW2401B-BC

144 RIBXGTA-ECM

88 SP4404L

194

TR50VA018

129

RIBMX24BA

105

RIBTW2402B-BC

145 RIBXGTA-NC

89 SP5503L

194

TR50VA019

129

RIBMX24BF

105

RIBTW24B-BCAI

151 RIBXGTA-SCAL

88 SP5504L

195

TR50VA022US

127

RIBMX24BV

105

RIBTW24B-BCAO

152 RIBXGTF

88 SP5803L

195

TR50VA027

129

RIBMX24SBA

105

RIBTW24B-MBAI

157 RIBXGTFL

88 SP5804L

196

TR75VA001

130

RIBMX24SBF

105

RIBTWX2401B-BC

147 RIBXGTF-NC

89 TR100VA001

130

TR75VA002

130

RIBMX24SBV

105

RIBTWX2402B-BC

149 RIBXGTV10

92 TR100VA001-28

130

TR75VA003

130

RIBPM413-BC

161

RIBU1C

22 RIBXGTV5

92 TR100VA001US

127

TR75VA004

130

RIBPM413-BC-KIT

160

RIBU1C-100PACK

22 RIBXGTV5-10

91 TR100VA002

130

TR75VA005

130

RIBR24D

35

RIBU1C-10PACK

22 RIBXJA

96 TR100VA002-20

130

TR75VA007

130

RIBR24D-NS

33

RIBU1C-25PACK

22 RIBXJF

96 TR100VA002US

127

TS-AN

200

RIBR24SD

35

RIBU1C-5PACK

22 RIBXK420-100

91 TR100VA004

130

TS-BC

200

RIBR24SD-NS

33

RIBU1CW

30 RIBXK420-20

91 TR100VA005

130

WDWS2-EN3

180

RIBRL1C

34

RIBU1S

23 RIBXK420-50

91 TR100VA008

130

WKC-EN3

180

RIBRL1C-NS

32

RIBU1SC

25 RIBXKA

87 TR100VA009

130

WSTP-W

182

RIBRL1S

34

RIBU1SM-250

24 RIBXKF

87 TR100VA009US

127

WVSCM-EN3

181

RIBRL1S-NS

32

RIBU2C

22 RIBXKNUTA

87 TR100VA015

130

WVSUS-EN3

182

RIBRXLCF

102

RIBU2S2

28 RIBXKTA

87 TR100VA026

130

WVSWM-EN3

181

RIBRXLCF-NS

101

RIBU2SC

28 RIBXKTF

87 TR100VA027

130

WWS2-EN3

180

RIBRXLSA

102

RIBW01B-EN3

177 RIBXKTV5-10

90 TR150VA001

130

RIBRXLSA-NS

101

RIBW01C-EN3

178 RIBXKTV5-100

90 TR150VA001-28

130

RIBT2401B

54

RIBW01F600-EN3

179 RIBXKTV5-20

90 TR150VA002

130

RIBT2401D

31

RIBW02C-EN3

178 RIBXKTV5-50

90 TR150VA008

130

RIBT2401SB

55

RIBW208B-EN3

177 RIBXLCA

98 TR175VA001

130

RIBT2401SBC

55

RIBW21BAO-EN3

178 RIBXLCEA

98 TR175VA002

130

RIBT2402B

54

RIBW240B-EN3

177 RIBXLCEV

98 TR175VA003

130

RIBT2402SB

55

RIBW24B-EN3

177 RIBXLCF

98 TR20VA001

129

RIBT2402SBC

55

RIBW277B-EN3

177 RIBXLCJA

98 TR20VA002

129

RIBT242B

57

RIBX243PA

104 RIBXLCJF

98 TR20VA003

129

(800) 888-5538 | www.functionaldevices.com

203

INDEX & RERENCES

INDEX & RERENCES

204

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

(800) 888-5538 | www.functionaldevices.com

205

INDEX & RERENCES

INDEX & RERENCES

206

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

(800) 888-5538 | www.functionaldevices.com

207

INDEX & RERENCES

INDEX & RERENCES

208

Functional Devices, Inc. | Confidence & Peace of Mind in Every Box®

RELAYS | CURRENT SENSORS | POWER SUPPLIES | TRANSFORMERS | POWER MONITORING | WIRELESS DEVICES
VIEW OR DOWNLOAD THE CATALOG
ON OUR WEBSITE
POWER CONTROL | SPECIALTY PERIPHERAL CONTROLS | ACCESSORIES | ENCLOSURES | INTELLIGENT FIELD DEVICES


Adobe InDesign 18.1 (Windows) Adobe PDF Library 17.0