User Manual for CONOTEC models including: DSFOX-XD20 10K Digital Temperature Controller, DSFOX-XD20 10K, Digital Temperature Controller, Temperature Controller

DSFOX-XD20 œX$–˝ ENG V1.0(220927) A3.ai

2 Model types DSFOX-XD20 5 Setting process ...

Jan 1, 2023 — This product was not made as a safe device. Therefore, this product should be attached with dual safety devices if it is used.

Jan 1, 2023 — ※ The specifications and dimensions specified in this instruction manual may be changed without any notice for performance ... • Temperature/humidity transmitter.

2 Model types DSFOX-XD20 5 Setting process Temperature setting Setting method 3 Components SET 4 Terminal wiring diagram 1 Safet


File Info : application/pdf, 2 Pages, 514.49KB

PDF preview unavailable. Download the PDF instead.

Manual-bo-dieu-khien-nhiet-do-conotec-DSFOX-XD20
Version 1.2(2022.09.27)
CONOTEC CO., LTD. Manual
1 Safety precautions

Digital Temperature Controller www.conotec.co.kr
- XD20
·A user manual for this product is posted on the company website. ·Please download the technical document and communications manual on the company website
www.conotec.co.kr

18. This product should be installed only by an expert or a qualified person.
19. The company will not be liable for any damage caused by the violation of the above warnings and cautions or by a consumer's fault
Danger Caution: Risk of electric shock
· Electric shock - Do not touch the AC terminal while the current current is flowing. It may cause an electric shock.
· You must disconnect the input power when servicing it.
2 Model types

Model

Sensor

Control Type

Temperature Range

Power

Function

DSFOX-XD20

NTC 10K

Relay contact (2EA)

Celsi - 55.0  us: ~ + 99.9 
Fahren - 60 

100~240 VAC
50/60Hz

Cooling/Heating control

heit:~ + 200 

3 Components

Please read the safety precautions carefully for correct operation of the product.  The specifications and dimensions specified in this instruction
manual may be changed without any notice for performance enhancement.
! Warning
1. This product was not made as a safe device. Therefore, this product should be attached with dual safety devices if it is used for the control purposes (e.g. a device vulnerable to accident and property damage, etc.).
2. Do not wire, inspect or service this product while the power is being supplied.
3. You must attach this product to a panel. Otherwise, it may cause an electric shock.
4. When connecting the power, you must check the terminal number. 5. Do not ever disassemble, process, modify or repair this product.
! Caution
1. Please make yourself familiar with all the operation instructions, safety precautions and warnings before using this product. Comply with related specifications and capacity requirements
2. Do not wire or install this product to any unit with high inductive load (e.g. motor, solenoid, etc.).
3. Use a shielded cable with a proper length when extending a sensor. 4. Do not use any part that generates an arc when used in the same
power or directly switched in close proximity.
5. Keep the power cable away from a high-voltage cable and do not install this product in any place that is full of water, oil and dust.
6. Do not install this product in any place that is exposed to direct sunlight or rain.
7. Do not install this product in any place that is subject to strong magnetic power, noise, vibration or shock.
8. Keep this product away from any place that generates strong alkaline or acid substances. Use a separate pipe.
9. Do not sprinkle water onto this product for cleaning when installing it in the kitchen.
10. Do not install this product in any place where the temperature/ humidity ratings are exceeded
11. The sensor cable should not be cut or cracked. 12. Keep the sensor cable away from a signal cable, a power cable
or a load cable. Use a separate pipe. 13. Keep in mind that the follow-up service will not be available if
this product has been arbitrarily disassembled and modified
14. ! symbol on the terminal wiring diagram indicates a safety statement that alerts a warning or caution.
15. Do not use this product near any device generating strong high-frequency noise (e.g. high-frequency welding machine high-frequency sewing machine, high-frequency radio, large-capacity SCR controller, etc.).
16. Using this product in any method other than those specified by by the manufacturer may lead an injury or a property damage
17. This product is not a toy. Keep it away from children

Product appearance and components

1

OUT1

2

OUT2

7

XD20
SET

345 6

1 OUT1 output display 2 OUT2 output display

3 SET switch

4 Back switch 5 Up switch

6 Down switch

7 Temperature unit

4 Terminal wiring diagram

[ DSFOX - XD20 ]
Sensor NTC 10K
1234

OUT1

A

CB

5678

OUT2
9 10 11 12

R1

R2

NRN

R1 NR

POWER SUPPLY

 Output: 250VAC 2A; A power relay or a magnet must be used.
 Be careful that any load over the contact capacity may cause cause contact fusion, contact defect, relay damage or others

5 Setting process

Setting method

Name

Image

Description

SET key Back switch Up/down key

SET
/

Entry into or return to the settings page Selection and saving of data values
Go to the previous menu when setting up a program
Increment/decrement of the selected menu data

Change of the temperature output's set temperature (temperature setting) 1) If you press the SET key once, the setting will blink and be displayed 2) Increase or decrease the setting with the or key.
Installer mode settings (Program settings)
1) Press the SET key for at least 5 seconds to enter into the installer mode.
2) Configure the program based on the temperature program configuration diagram.
3)Press key for Enter the previous setting menu (* Program setting mode only)

Out1 setting temp
Blinking setting
Change of the set temperature
Out2 setting temp
Blinking setting
Change of the set temperature
OK (setting confirmation text)
Current temperature

SET

Press the key for at least 5 seconds.

Program setting

Temperature unit setting
SET

SET
OUT1 function option
SET
SET
OUT1 Deviation temperature setting
SET

OUT2 function option
SET
SET
OUT2 Deviation temperature setting
SET

SET
SET
(00M 00S)
SET

SET
OUT2 delay time setting
SET
(00M 00S)
SET

Temperature setting
The current temperature will be displayed.
SET

SET
Use the or the setting.

key to change

SET

Press the SET key after changing the setting.

SET
Use the or the setting.

key to change

SET

Press the SET key after changing the setting.

OK, a setting confirmation text, will be displayed, and the current temperature will be shown.

Temperature correction setting
SET
SET
Lock setting
SET
SET

6 Function details

7 Setting range and factory settings

: Change of the temperature unit - (temperature displayed in Celsius)
- (temperature displayed in Fahrenheit)

 Note: If you change the while the product is running, all the settings except for the unit will be initialized to factory settings. Please reset all the settings.

: Output function option
- Cooling ( ) or heating ( ) : Deviation temperature setting
- For on/off control, there should be a certain interval
between on and off. - A relay or other output contacts may be quickly
damaged or experience hunting (electricity generation, chattering, etc.) due to an external noise if the on/off function is used too frequently. - Different temperature is set to prevent such phenomenon and protect relevant contacts.

- Example 1) Set temperature - Example 2) Set temperature

: 20.0,

,

: 20.0,

,

15.0

Output ON

Set point (oFF) 20.0

Display Function
Temperature setting
Temperature unit
Output1 function option

Applicable range Applicable range

in Celsius

in Fahrenheit

Output1 deviation temperature setting
Output1 delay time setting

Output2 function option

Output2 deviation temperature setting

Output2 delay time setting

Temperature correction setting
Lock option

Factory setting

Remarks

c : Celsius f : Fahrenheit

minutes, seconds

minutes, seconds
Correction of the difference between the displayed temperature & actual temperature

9 Easy error diagnosis instructions

 If an error is displayed while the product is running

· : It is a case where the product was subject to a strong external

noise and internal data memories have been damaged In this case, contact us for product service ·Although this controller was designed to withstand a certain level of external noise, it is not supposed to withstand all levels of noise ·If the product is subject to a noise greater than 2KV, it could be internally damaged.

·If ` ' (open error) or ` ' (short error) is displayed, there is

something wrong with a sensor. Please check the sensor

·If `

' (OK) is displayed, settings have been saved.

·A text such as `

' (lock) indicates that the product is

in the lock mode

·IF `

' (product name) is displayed, it refers to a model name.

·IF `

' (product name) is displayed, it refers to a model name.

MEMO

MEMO

10.0 Set point (oFF)

15.0

Output ON

< Cooling>

< Heating>

: Output delay time setting
- Used if the on/off function of a control target is used too frequently (freezer, compressor, etc.)
- Protects running machine from momentary outage or power re-connection
e.g.) When is the output on for the following conditions: set temperature (10.0); (00.30), (5.0°C)?

Output stopped

30 seconds

Temperature output

(Current temperature) section applied
10.0 15.0

: Correction of the current temperature

- Used to correct the current temperature based on the

reference temperature (e.g. mercury thermometer,

existing thermometer, thermostat, etc.) when there is

an input error by an external sensor even though

the product itself does not have any problem

e.g.) Actual temperature: 10.0

Display window : 12.0

Modification of 0.0 to -2.0

Displayed as 10.0 (current temperature modified)

8 Product dimensions and panel processing dimensions

77.0mm 71.0mm

(Unit: mm / error: ±0.5) 71.0mm

SET
66.5mm 61.0mm

36.0mm

PANEL HOLE

29mm

4.0mm

: Locking of the setting
- Safety function intended to prevent anyone other than the main user from changing the settings -If set at : All the settings except for the set temperature will be locked. -If set at : All the settings will be unlocked.

 The above specifications may be changed without any notice
for performance enhancement. Please make yourself fully familiar with and follow the above precautions.

Address: (Street address) 56, Ballyongsandan 1-ro, Jangan-eup, Gijang-gun, Busan, ROK

(Land-lot address) 901-1, Ballyong-ri, Jangan-eup,

Gijang-gun, Busan, ROK (46034)

·Product service : 070-7815-8266

·Customer service: 051-819-0425 ~ 0427

·FAX : 051-819-4562

·Website : www.conotec.co.kr

·Email : conotec@conotec.co.kr

·SNS : Facebook,Instagram,Twitter,YouTube `Search for `Conotec'

 Installation precautions

This device should be connected to a protective earth terminal and

a power supply in order to prevent an electric shock.

Do not block the air outlet.

 Operation precautions

 An operating environment of this device is as follows.

Ambient temperature: 0 ~ 60 Ambient humidity: 80% RH or less

Indoor uses only

Pollution class: 2

Altitude under 2000m

Installation category: ll

This device should be laid out in a way that its power cord

is easy to handle

Using this product in any method other than those specified by

the manufacturer may damage its protection function

Major products and development

· Temperature/humidity controller · Unit cooler controller

· Counter and timer controller

· Heat pump controller

· Current and voltage panel meter · Chiller controller

· Temperature/humidity indicator · Thermo-hygrostat controller

· Oven controller

· Short message alarm

· CO2 controller

· Temperature/humidity transmitter

· PID controller

· Smartphone app and monitoring system

 This manual was prepared in the Naver Nanum fonts.


Microsoft: Print To PDF