Hisense Portable Air Conditioner

QUICKSTART

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.

Keep unit upright at least 2 hours prior to use.

Parts Package

Before beginning, check that all parts are included in the parts package.

Tools needed

step 1: Suitable Windows

The window installation kit allows you to install the air conditioner in most vertical-sliding windows 25" to 50" wide, or horizontal-sliding windows from 25" to 50" high.

Choose the right panel

Window25"9 ½"18"18"
25"
25" 33"
25" 42"
43" 50"

Panel H (25"), Panel J (18"), Panel K (18")

Window Installation

  1. Cut the adhesive foam seal to the proper length, and attach it to the window sash and frame.
  2. Insert the vent panel assembly, including extension panels, if needed, into the window opening. Extend the extension panels, if used.
  3. If your window length requires more than two panels, after adjusting the length, please secure the panels with rivets.
  4. Cut the Non-adhesive foam seal to the window width. Stuff the foam seal between the glass and the window to prevent air and insects from getting into the room.
  5. Install the Window-lock bracket with wood screws as shown, if you need.

step 3: Connect it together

  1. Preparing the exhaust hose assembly: Press the flexible exhaust hose into the coupling and the window exhaust adapter. Both the coupling and window exhaust adapter have integral clips that snap onto the hose.
  2. Connect The Hose To The Air Conditioner: Slide the coupling into the slot on the back of the air conditioner to lock the hose on the unit.
  3. Connect The Hose To The Window: Roll the air conditioner to the selected location. Attach the window exhaust adapter to the outer slider section (the piece with the large exhaust hole).

Waterless Design

  1. Waterless Design doesn't require routine draining in cooling mode due to internal evaporation of condensate water.
  2. Code "E5" alerts you the internal tank has become full. Please drain the air conditioner according to the instructions in the User Manual.
  3. Before moving the unit, place a pan on the floor beneath the drain cover and remove the drain cover to drain the water.
  4. Be sure to replace the drain cover when draining is complete.

Draining the Air Conditioner (Heat Pump models only)

  1. Uncover the drain port.
  2. Connect the drain hose to the drain port. Make sure the connector does not have a water leak.
  3. Place the other end of drain hose into a drain. Check to see that the hose lies flat and is in the drain. Make sure the hose end that goes to the drain is on a lower level than the hole end that connects to the unit. The hose should not be kinked or pinched.

To ensure proper ventilation, keep a distance of at least 20in (50 CM) between the Portable AC and the window.

step 5: Turn The Unit On

Turn the air conditioner on, and set the desired mode and temperature.

step 4: Plug In the Unit

Be sure to use a grounded 3 prong outlet. Do not use an extension cord. Plug in the unit.

See the user manual for detailed instruction on installation and using the features and settings of the air conditioner and remote control.

For questions about features, operation/performance, parts or service, Call: 1-877-465-3566 Monday to Friday: 9:00 a.m.- 6:00p.m. (EST) or Visit: www.hisense-usa.com

The figures in this manual are based on the external view of a standard model. They may differ from that of the air conditioner you have selected.

PDF preview unavailable. Download the PDF instead.

frhwkhoiuxfo Adobe Illustrator(R) 15.0 (C) 2018 Retailer Web Services LLC, all rights reserved.

Related Documents

PreviewHisense 550 sq. ft Portable AC Use & Care Guide
A comprehensive guide for the Hisense 550 sq. ft Portable Air Conditioner, covering installation, operation, care, and troubleshooting.
PreviewHisense 550 sq. ft Portable AC Use & Care Guide
This guide provides instructions for the safe use, installation, and maintenance of the Hisense 550 sq. ft Portable Air Conditioner, Model AP55023HR1GD. It includes safety precautions, installation requirements, operating modes, remote control functions, and troubleshooting tips.
PreviewHisense Portable Air Conditioner Quick Start Guide
A concise guide for setting up and operating your Hisense portable air conditioner, covering parts, window installation, hose connection, and essential safety information.
PreviewHisense Portable Air Conditioner Quick Start Guide
Concise guide to setting up and installing your Hisense portable air conditioner, including parts identification, window installation, hose connection, and basic operation.
PreviewHisense Portable Air Conditioner Quick Start Guide
A quick start guide for setting up and installing a Hisense portable air conditioner, including window installation and hose connection instructions.
PreviewHisense Portable Air Conditioner Quick Start Guide
A concise guide to setting up and operating your Hisense portable air conditioner, including window installation and basic operation.
PreviewHisense AP0621CR1W Ultra-Slim Portable Air Conditioner User Manual
User manual for the Hisense AP0621CR1W Ultra-Slim Portable Air Conditioner. Covers safety, operation, maintenance, and troubleshooting for optimal performance.
PreviewHisense AP08CR2W Ultra-Slim Portable Air Conditioner - Features and Specifications
Discover the Hisense AP08CR2W Ultra-Slim Portable Air Conditioner. This 8K BTU unit cools up to 200 sq.ft. and features quiet operation, multiple modes, and an I-Feel remote control. Includes detailed specifications and window kit requirements.