User Manual for digitella models including: R5000, 2A8DXR5000, R-5000 UHF RFID Bluetooth Handheld Reader, R-5000, UHF RFID Bluetooth Handheld Reader, RFID Bluetooth Handheld Reader, Bluetooth Handheld Reader, Handheld Reader, Reader

02203 KC R5000 메뉴얼수정5

thomas

User Manual

Digitella Inc. R5000 UHF RFID READER 2A8DXR5000 2A8DXR5000 r5000


File Info : application/pdf, 16 Pages, 646.73KB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7739896
R-5000 UHF RFID Bluetooth Handheld Reader
USER MANUAL

CONTENTS

CONTENTS

2

ABOUT THIS MANUAL

3

Revision History

3

Relevant Document

3

Service Information

3

OVERVIEW

4

Package

4

Feature

5

Indicators

6

GETTING STARTED

7

Charging the Device

7

Installing the Battery

8

Bluetooth Pairing

9

NFC Tap to Pair

9

QR Code Pairing

10

USING THE DEVICE

11

Reading Tags

11

Scanning Barcodes

11

TAGFOCUS AND FASTID TAG SUPPORTED

12

Type of tags supported

12

Monza Model Numbers

12

CERTIFICATION

13

KC Certification

13

FCC Warning

13

SAFETY INFORMATION

14

Battery Safety

14

Battery Usage & Disposal Guidelines

14

Battery Storage Guidelines

14

Laser Safety

15

APPENDIX. SPECIFICATION

16

Copyright  2024 Digitella Inc. All rights reserved.
2

ABOUT THIS MANUAL

Revision History

Revision 1.0 1.1 1.2
1.3
1.4 1.5 2.0

Date

Description

July 28, 2022 - First version released August 17, 2022 - `NFC Tap to Pair' [NOTE] Added

- Charging the Device [NOTE] Added August 22, 2022 - `SAFETY INFORMATION' Added

- `R-5000 Device (without barcode)' Deleted

October 21, 2022

- Charging the Device [NOTE] Added - `KC Certification' Added - `Laser Safety' Added to SAFETY INFORMATION

November 9, 2022

- `FCC Warning' Added

November 25, - `USING THE DEVICE' Added 2022

July 12, 2024 - Overall company information and company logo revised

Relevant Document
Programming Barcode Manual RSP Interface Programmers Guide

Service Information
If you have a problem with your device, please contact Digitella Inc. For RMA requests, please visit http://www.digitella.net/contact.

Copyright  2024 Digitella Inc. All rights reserved.
3

OVERVIEW
Package

R-5000 Device (with barcode)

Battery [NOTE] Adaptor and USB-C Cable are included.
Optional

Hand strap

[NOTE] Cradle is sold separately.

Cradle

Copyright  2024 Digitella Inc. All rights reserved.
4

OVERVIEW

Feature
R-5000 with Barcode scanner

Charging LED Power Button
No. 1 2
3
4
5
6 7 8 9 10 11 12

 Trigger Key

 Sound Hall  NFC Tag

 Bluetooth Key

 Sound Mode Key  Function Key
 Hand strap Hall

 Barcode Scanner
R-5000 Device (with barcode)

 USB Port

 Battery Button

Name Power Key Charging LED
Trigger Key
Sound Key
Function Key
Bluetooth Key Barcode Scanner
Sound Hall NFC Tag USB Port Hand strap Hall Battery Button

Description Press and hold for 3 seconds to turn on/off the device. It makes a beep sound and is powered on. Indicates the charging status and the battery level. The battery power is shown in 3 level. Reads tags or scans barcodes by pressing key. In RFID mode, read the data continuously while pressing key. In Scanner mode, scanning stops once the barcode has been read. Press the key to change the Sound mode: Sound ­ Sound & Vibration ­ Vibration ­ Mute. In case of connecting with iOS terminals in HID mode, hold the key for 3 seconds to keyboard pop up on display. Press the key to change the RFID mode, RFID tag reading or barcode scanning. Hold the key for 3 seconds to delete the data stored in local memory. Press the key to turn on Bluetooth. Hold the key for 3 seconds to delete the Bluetooth connected list(Un-bonding).
Scans barcodes by emitting a red laser.
You can hear a beep sound from the sound hole.
You can connect the device with NFC.
You can charge the data communication with the host terminal using USB cable.
Install the handstrap through the hole.
Press the button below to replace the battery.

Copyright  2024 Digitella Inc. All rights reserved.
5

OVERVIEW

Indicators
LED CHARGING
SOUND

Status OFF 3-WHITE-LED 2-WHITE-LED 1-WHITE-LED Blink GREEN BLUE RED OFF

Description Battery exhausted Battery level is High Battery level is Middle Battery level is Low
Battery fault Only sound Sound & Vibration Only Vibration
Mute

FUNCTION

RED BLUE

Scanner mode RFID mode

BLUETOOTH

BLUE RED BLUE-Blink RED-Blink OFF

SPP(UART) Profile
HID Keyboard Not connect in SPP(UART) Profile
Not connect in HID Keyboard Not connect because the USB Data cable is
connected.

[NOTE] The Charging indicator shows only a rough estimate of battery power and does not show an accurate remaining power level. Therefore, please charge the device early. [NOTE] At battery level 10%, the device sounds beep every 1 minute. At battery level 5%, it sounds beep every 30 seconds.

Copyright  2024 Digitella Inc. All rights reserved.
6

GETTING STARTED
Charging the Device
01 Charging with Adaptor
 Assemble the plug and the AC/DC adaptor and connect the USB-C cable to charge the device. [NOTE] Use an original charger adaptor and cable from Digitella Inc. Other chargers and cables may damage the device. Please refer to SAFETY INFORMATION for safety of using battery. [NOTE] When charging the battery, the highest temperature is 45°C. 02 Charging with Cradle
 Take care not to involve a hand-strap between the device and the cradle.  Push down the device on the cradle securely. [NOTE] When removing, pick up the device holding the cradle with one hand.
Copyright  2024 Digitella Inc. All rights reserved.
7

GETTING STARTED
Installing the Battery
 Place the top of the battery fully forward to into the battery holder and push down on the bottom of the battery.  To replace the battery, press down the battery button. [NOTE] If a device is not working properly or freezes due to unknown errors, please pull the battery out and resert it. And press the Power key to turn on the device.
Copyright  2024 Digitella Inc. All rights reserved.
8

GETTING STARTED
Bluetooth Pairing
You can use Bluetooth to connect the device to host terminals.  Turn on the Bluetooth function of the host terminal.  Power on the device and Bluetooth indicator will blink (Blue ­ SPP(UART) profile, Red ­ HID mode).  Select this device from the device list of the host terminal to pair.
The device name is displayed as "R-5000(XXXXXX)".  When Bluetooth pairing is successful, blink stop and indicator illuminates continuously.
[NOTE] The device can pair automatically with the last connected host terminal. [NOTE] As for iOS, to pair a new host terminal, please turn off the Bluetooth function or delete the device from the device list of the host terminal paired before.
NFC Tap to Pair
 Turn on the NFC function of the host terminal.  Keep touching your mobile device next to sound hall on the top of R-5000. [NOTE] Depending on the country and specifications of the mobile device, it does not support NFC. Please refer to the instruction manual of your mobile device(Android). [NOTE] If the connection does not work, please do the following: - If the mobile device is locked, please release the lock and move it slowly on the NFC. - If the mobile device is in a protective case, please remove the case. - Check your mobile device's Bluetooth turn on. [NOTE] As for iOS terminal, NFC function is not available.
Copyright  2024 Digitella Inc. All rights reserved.
9

GETTING STARTED
QR Code Pairing
You can use QR Code attached to the device to connect the host terminals.  Install the `KCI RFID' Mobile Application form the Google Play Store.  Launch the `KCI RFID' on the mobile host terminal.  Press the "QR Code Scan" button from the menu in the upper right and read the QR code on the label
attached to the device.

Copyright  2024 Digitella Inc. All rights reserved.

10

USING THE DEVICE
Reading Tags
To read tags using the R-5000,  Turn on the R-5000 and check the RFID mode (Function LED ­ BLUE).  If not in RFID Mode, press the Mode key to change the mode.  Connect the host terminal to device.  Hold the device in the direction of the tag to be read and press the Trigger key.
[NOTE] When the tag is read successfully, you will hear a beep sound (In Sound, Sound & Vibration mode).
Scanning Barcodes
To scan barcodes using the R-5000,  Turn on the R-5000 and check the Scanner mode(Function LED ­RED).  If not in Scanner Mode, press the Mode key to change the mode.  Connect the host terminal to device.  Hold the device in the direction of the barcode to be scanned and press the Trigger key.
[NOTE] When the barcode is scanned successfully, you will hear a beep sound (In Sound, Sound & Vibration mode).

Copyright  2024 Digitella Inc. All rights reserved.

11

TAGFOCUS AND FASTID TAG SUPPORTED

TagFocusTM and FastIDTM are only available for Monza Tag chip, manufactured by Impinj.
Type of tags supported

Model

Monza 4

4D

4E

Tag FocusTM V

V

FastIDTM

V

V

Monza 5

4QT

5

R6

V

V

V

V

V

V

Monza 6

R6-P V

S6-C V

V

V

Monza X

2K

4K

V

V

V

V

Monza Model Numbers

Family Monza 4 Monza 5 Monza 6 Monza X

Model
4D 4E 4QT 5 R6 R6-P S6-C 2K Dura 8K Dura

TID Memory Address 0x00 ~ 0x1F
0xE2801100 0xE280110C 0xE2801105 0xE2801130 0xE2801160 0xE2801170 0xE2801171 0xE2801140 0xE2801150

Copyright  2024 Digitella Inc. All rights reserved.

12

CERTIFICATION

KC Certification

This product is an industrial equipment used in manufacturing or production process, and it is a wireless equipment that has received conformity assessment(registration of conformity) according to Article 58-2 of the Radio Waves Act.

Conformity Assessment Mark Applicant
Model Name Equipment Name Manufacturer / Country of Origin Certification number Certified Wireless Module
Information

Digitella Inc. R-5000 RFID/USN Wireless Device (900MHz Frequency band) Digitella Inc. / Korea R-R-D0t-R5000
R-C-ryt-MDBT50

FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The device complies with RF exposure requirement.

Copyright  2024 Digitella Inc. All rights reserved.

13

SAFETY INFORMATION

Battery Safety
Follow battery safety guidelines in this manual for safe usage and disposal of Li-ion batteries. Improper battery use may cause an explosion, fire, or other critical hazards.
Battery Usage & Disposal Guidelines
Use only R-5000 approved batteries and charging accessories. Using an incompatible battery or charger may cause device malfunction or other damage.
- Do not disassemble or modify the battery. Do not bend, shred, deform the battery. - Do not expose the battery to excessive heat or cold. - Do not place the battery into a microwave oven or dryer. - Do not short-circuit the battery or allow a foreign object to battery contacts. - Do not burn, expose to water, or other liquids the battery. - If battery leakage is observed, avoid any contact with the skin or eyes. - If contact has been made, wash the affected area with water for 15 minutes, and seek medical attention. - Follow the local regulations for the disposal of used batteries. - Do not store or charge the battery in direct sunlight or in areas prone to get hot such as on the dashboard of a
car extended periods of time, or close to other heat sources.
Battery Storage Guidelines
Storing batteries is as important as using it safely. Battery is a core part of the device's performance so that you should treat the batteries safely.
- Batteries should be stored in the clean, dry and ventilated environment within ambient temperature ranges of 20±5°C.
- Keep batteries away from corrosive substances. - Keep batteries away from fire and heat. - Batteries are charged while producing to below 30% of full capacity for safety regulations. - Charge it for 30 minutes ­ 1 hour at least once every six months to prevent full discharge and keep the
performance, when you are not using the device for a long period.

Copyright  2024 Digitella Inc. All rights reserved.

14

Laser Safety
Class 2 laser Product 1.0mW MAX OUTPUT 650nm LASER. LASER LIGHT. Do not stare into beam.

Copyright  2024 Digitella Inc. All rights reserved.

15

APPENDIX. SPECIFICATION

Category

Description

PHYSICAL CHARACTERISTICS

Dimension Weight
Power Notification

55 x 169.5 x 32.8 (W x H x D)
Approx. 250g(Including battery, w/o Barcode option)
18.513Wh (5100mAh@3.63V), Li-ion Battery,
DC 7.26V, Charging Input power: DC 5V
Beeper, Vibration, 4LEDs

User Input

Power/Trigger/Sound/Mode/BT Key

ETC Option Protocol Chip

1D/2D ISO 18000-63 (Old.18000-6C)/
EPC Global Class 1 Gen 2 Impinj® Reader Chip

RFID PERFORMANCE

MCU

ARM® Cortex®-M4, 32bit

Antenna

Circular polarization

Reading Speed
Frequency Range/ RF Output
Communication Interface

700+ tags/sec
840-960MHz/up to 30dBm (1W) (Frequency Range varies from country to country)
Bluetooth(LE), USB

COMMUNICATION

Bluetooth USB Interface
Sealing

v5.1 BLE (SPP, HID) USB Type C, USB to Serial, USB 2.0
Compliant, Charging IP65

Drop Spec.

1.5m

USER ENVIRONMENT

Operating Temp. Storage Temp.

-10°C to 50°C -40°C to 85°C

Charging Temp.

0 °C to 40°C

Humidity

5-95% non-condensing

Copyright  2024 Digitella Inc. All rights reserved.

16



References