Laboratory Filtration Catalogue

Minisart, Sartolab, Sartoclear, Filtration, Ultrafiltration, Filter Papers, Membrane Filters, Combisart, Claristep, Syringe Filters, Protein Concentration, DNA concentration, Viirus Purification, Viaspin, Vivaflow, Vivapore, Centrisart, Vivacon

Laboratory Filtration Catalogue

65 Filtration Devices Table of Contents Filtration Device Portfolio Introduction 66 Minisart Standard Selection Guide 67 Minisart PP Standard Syringe Filter 68 Minisart NML Standard Syringe Filters 74 Medical Device CE-Minisart Syringe Filters 80 Claristep Syringeless Filtration 83 Sartolab P20 and Sartolab P20 Plus 87 Sartolab RF | BT 91 ...

manual 676(1)
65
Filtration Devices
Table of Contents

Filtration Device Portfolio Introduction

66

Minisart® Standard Selection Guide

67

Minisart® PP Standard Syringe Filter

68

Minisart® NML Standard Syringe Filters 

74

Medical Device CE-Minisart® Syringe Filters

80

Claristep® Syringeless Filtration 

83

Sartolab® P20 and Sartolab® P20 Plus 

87

Sartolab® RF|BT 

91

NEW! Sartolab® RF 50 

94

NEW! Sartolab® Multistation 

96

Sartoclear Dynamics® Lab P15 

98

NEW! Sartoclear Dynamics® Lab V 

100

Chemical Compatibility 

104

66

Filtration Devices Introduction

Introduction

Syringe filters are used for many routine preparation steps in laboratories all over the world. They are convenient, ready-to-use disposables for sterile filtration of liquids and removal of particles from solutions and gases. Depending on the reagents filtered, syringe filters have to fulfill certain requirements to best serve customer's application. Sartorius offers Minisart® syringe filters and filters optimized for a wide range of relatively large volumes. The filters are reliably remove particles with no leakage. If you need to rely on the quality of your filtrate ­ whether it needs to be sterile prior to use or particulate-free before analysis ­ fieldproven, high-quality Sartorius filter syringes are the No. 1 choice for reliable, convenient preparation steps.

Sartorius has developed a new, easy-to-use and straightforward filtration setup. The manually operated Claristep® Filtration System consisting of a station and filter units offers a novel way for clarifying your samples prior to analysis.
Claristep® Filter units are processed without syringe and are made of the purest materials. Another major benefit is that the contact time of the samples with the filters and the caps is extremely short, ensuring optimal, contamination-free results. The Claristep® Station consists of a base, a lid and an exchangeable tray for easy and accurate positioning of sample vials and Claristep® Filter units.

Our Product Range For clarification and sterilization of liquids, filtration is the optimal method. It removes microorganisms and particles reliably, without any effects on the ingredients due to adsorption or decomposition. For optimal results, Minisart® NML Standard syringe filters with an MBS housing provide a choice of membranes with pore sizes ranging from 0.1 m to 5 m for high flow rates and the low adsorption characteristics. The effective filtration area of 6.2 cm2 for the fast filtration is the largest among premium syringe filters available, and the MBS housing is color- coded for easy pore size identification. For a list of the types offered, please see page 74.
Elimination of particles from your samples prior to HPLC or other chromatographic analysis is essential in order to maintain the integrity of your chromatography column and to maximize its operating lifetime. Minisart® PP Standard syringe filters optimized for sample preparation consist of a polypropylene housing and membrane components featuring maximum chemical compatibility and minimum extractables to ensure excellent results. Due to the typical range of volumes from less than 1 mL to 100 mL, these filters are available in three different diameters with an effective filtration area of 0.07 cm2, 1.7 cm2 and 4.8 cm2. For a selection guide, please see page 67..
The Sartorius medical device CE-Minisart® syringe filter with a hydrophilic (surfactant-free) cellulose acetate and hydrophobic polyt etrafluoroethylene (PTFE) are the perfect choice for pharmacy admixture applications like sterile filtration and|or clarification of low volume solutions in a laboratory environment before use for patient care. The CE-Minisart® syringe filters are manufactured by Sartorius in a facility whose Quality Management System is certified for compliance with EN ISO 13485 (see page 80).

Claristep® syringeless filter units with RC membranes are optimized for solvents and aqueous solutions. They provide maximum chemical compatibility and exceptionally low non-specific binding of analytes.
Sartolab® vacuum filtration devices with 0.1µm and 0.22µm PES membranes for convenient filtration of 150mL up to 1 L are ready to use and sterile. Sartolab® RF is a complete syst em that includes a receiver flask. Sartolab® BT Sterile is a bottle top filter without a receiver flasks. This enables customers to use a receiver bottle of their choice and to even expand filtration capacity, depending on the particle load of the filtered liquid by filling more than one receiver flask. Sartolab® 150V is a disposable vacuum filter with a pleated 0.22µm PES membrane, which is suitable for up to 15 L of liquid.
Sartolab® P20 pressure filtration devices with a 0.2µm and 0.45µm PES membrane are available with or without a glass fiber prefilter, depending on your needs. Sartolab P20 is designed for up to 3 L volumes and can also be used in-line. The polycarbonate housing and membrane components are ideal for filtering liquids. The glass fiber prefilter types are ideal for filtering environmental samples that have a high particle load prior to analyzing such samples.
----Typical Applications for Filtration Devices
Sterile filtration of liquids and gases with virtually no effect on the ingredients Particle removal from liquids and gases prior to downstream processes Venting of vials, bottles, containers, bags and bioreactors and fermenters Removal of precipitates and coagulates from solutions prior to use

Minisart® Standard Syringe Filters are not for medical use.

Filtration Devices Minisart® Syringe Filters

67

Minisart® Standard Selection Guide

Please refer to Minisart® RC, NY or SRP for the highest chemical compatibility on page 71. Please refer to Minisart® NML or Minisart® High Flow on page 74.

Sample Composition

Aqueous

Aqueous|Solvents

All Aqueous Solutions All Aqueous Solutions Buffers, Protein Analysis Tissue Culture Media

Aqueous|Solvent Solvent Mixtures|

Mixtures|Solvents

Solvents

Solvents|Gases| Acids|Bases

CA Cellulose Acetate

PES Polyethersulfone

RC Regenerated
Cellulose

Hydrophilic

NY Polyamide, Nylon

PTFE Polytetrafluoro
ethylene
Hydrophobic

Pore Sizes

Sterilization

Sample Preparation|Clarification|Particle Removal

Prefiltration

Small Bacteria Mycoplasma Colloids
>0.1

UHPLC, etc. (Columns <3µm Particles) Bacteria

HPLC, etc. (Columns
>3µm Particles) Particles

Particles Yeast Cells

Particles Yeast Cells

Particles Yeast Cells
Platelets

Large Particles
Cells

Glass Prefilter Glass+Membrane
Highly Particle-laden
Samples

0.1µm

0.2µm

0.45µm 0.65µm

0.8µm

1.2µm

5µm

GF (Glass Fiber)

Sample Volumes

1mL to 200mL 28mm for up to 200mL

1mL to 100mL 25mm for up to 100mL

0.5mL to 15mL 15mm for up to 15mL

0.05mL to 1mL 4mm for up to 1mL

68
4mm packages are color-coded Male Spike Outlet
Male Luer Slip Outlet Minisart® RC 15mm Minisart® NY 15mm Minisart® SRP 15mm

Filtration Devices Minisart® Syringe Filters
Minisart® PP Standard Syringe Filter Sample Preparation for Analytics
Reliable Removal of Particles from Liquids and Gases Particle removal by filtration before analysis substantially increases the lifetime of your columns. Minisart® RC is optimized for aqueous liquids and solvents and is compatible with DMSO, other amides, ketones, esters and ethers. Minisart® NY is exceptionally pure compared with other common polyamide (=nylon) filters and competitor products. For this product raw materials are used which do not interfere with standard analytical methods.
Our coating-free hydrophobic PTFE membrane used in Minisart® SRP is suitable for venting applications.
---Minisart® Features
Low adsorption of analytes Maximum chemical compatibility Minimum extractables

Minisart® RC 25mm

Minisart® NY 25mm

Minisart® SRP 25mm

Filtration Devices Minisart® Syringe Filters

69

HPLC Certification

mAU 70 60 50 40 30 20 10 0 -10 0
mAU 70 60 50 40 30 20 10 0 -10 0
mAU 70 60 50 40 30 20 10 0 -10 0

Methanol

10

20

30

40

50

60 min

Acetonitrile

10

20

30

40

50

60 min

Water

10

20

30

40

50

60 min

 Filtered with Minisart® SRP  Filtered with Minisart®NY  Filtered with Minisart® RC  Unfiltered Methanol
 Filtered with Minisart® SRP  Filtered with Minisart®NY  Filtered with Minisart® RC  Unfiltered Acetonitrile
 Filtered with Minisart® PES  Filtered with Minisart® NML  Unfiltered Water

HPLC Procedure Column C18: 250×4.6mm, Flow Rate: 1mL/min, Wavelength: 220nm HPLC Injection Volume: 20µL, Analysis Time: 65min, Temperature: 40°C, Mobile Phases: A) Acetonitrile| B) Water, Gradient: Hold 60% A for 10min, 60% to 95% A in 20min, 95% to 100% A in 35min

70
Minisart® with Polypropylene Housing

CFihltarapttieorn Devices Minisart® Syringe Filters

Specifications

Minisart® RC|SRP|NY|PES with 4|15|25mm  Membrane Filtration Area

Housing material

Polypropylene (PP)

Membranes

RC = Regenerated Cellulose|NY = Polyamide| SRP = Hydrophobic PTFE = Polytetrafluoroethylene|PES = Polyethersulfone| PES - = hydrophobic PES

Glass fiber prefilter

NY Plus: Ultrapure quartz, 0.7µm particle retention

Max. operating pressure

4.5bar|65psi Minisart® PES - : 2.0bar|29psi (IN - OUT) or 0.5 bar|7psi (OUT - IN)

Housing burst pressure

7bar|102psi

Max. temperature

60°C

Sterilization

Non-sterile Minisart® can be autoclaved or sterilized by ethylene oxide (EO)

Minisart® Membrane Types
Non-sterile packs: 50 (K), 200 (S), 500 (Q), 1000 (R)|sterile packs: individually packaged, 50 (ACK)
Bubble point ()

RC 0.2µm K | S | Q | R
With water 3.0bar|44psi

RC 0.2µm ACK
With water 4.6bar|67psi

RC 0.45µm K | S | Q | R
With water 2.0bar|29psi

---Flow rate (() mL/min), 4mm  = 0.07cm2 filter area|Hold-up volume1: 10µL

For water at 1bar

0.5

­

For methanol at 1bar

1.5

­

For air at 0.1bar

­2

­

1.5 3.0 ­2

---Flow rate (() mL/min), 15mm  = 1.7cm2 filter area|Hold-up volume1: 100µL

For water at 1bar

20

10

For methanol at 1bar

55

25

For air at 0.1bar

­2

­2

40 105 ­2

---Flow rate (() mL/min), 25mm  = 4.8cm2 filter area|Hold-up volume1: 200µL

For water at 1bar

80

50

For methanol at 1bar

160

90

For air at 0.1bar

­2

­2

160 325 ­2

Water penetration point3 ()

­

Sterile filtration capability5 acc.

No

to the bacteria challenge test

Non-pyrogenic according to the USP

­

­

Yes

No

SRP 0.2µm K | S | Q | ACK
With ethanol 1.1bar|16psi
­3 2.0 30
­3 55 800
­3 60 1,800
4.0bar|58psi Yes

SRP 0.45µm K | S | Q
With ethanol 0.9bar|13psi
­3 4.5 60
­3 150 1,600
­3 260 3,000
3.0bar|44psi No

Filtration Devices Minisart® Syringe Filters

71

Minisart® Membrane Types
Non-sterile packs: 50 (K), 200 (S), 500 (Q), 1000 (R)|sterile packs: individual packaged, 50 (ACK)
Bubble point ()

NY 0.2µm K | Q | R | ACK
With water 3.0bar|44psi

NY 0.45µm K | Q | R | ACK
With water 2.0bar|29psi

NY Plus 0.2µm NY Plus 0.45µm PES 0.2µm

K | Q

K | Q

K | Q | ACK

With water 3.0bar|44psi

With water 2.0bar|29psi

With water 3.2bar|46psi

PES -0.2µm K | Q
With ethanol 0.95bar|14psi

---Flow rate (() mL/min), 4mm  = 0.07cm2 filter area|Hold-up volume1: 10µL

For water at 1bar

­

­

­

For methanol at 1bar

­

­

­

For air at 0.1bar

­

­

­

­ ­ ­

1.5

­

­4

­

­2

­

---Flow rate (() mL/min), 15mm  = 1.7cm2 filter area|Hold-up volume1: 100µL

For water at 1bar

20

40

­

For methanol at 1bar

40

110

­

For air at 0.1bar

­2

­2

­

­ ­ ­

40

­

­4

­

­2

­

---Flow rate (() mL/min), 25mm  = 4.8cm2 filter area|Hold-up volume1: 200µL

For water at 1bar

50

100

50

For methanol at 1bar

70

200

70

For air at 0.1bar

­2

­2

­2

100

100

200

­4

­2

­2

­ ­4 1,200

Water penetration point3 ()

­

­

­

­

­

2.0bar|29psi

Sterile filtration capability5 acc.

Yes

No

Yes

No

Yes

Yes

to the bacteria challenge text

Non-pyrogenic according to the USP

1 Hold-up volume after air purge 2 Hydrophilic membranes can filter dry air or gas but become impermeable to air or gas when wetted! 3 Hydrophobic membranes cannot be wetted with aqueous solutions unless you overcome their water penetration point or pre-wet them using
an organic solvent (e.g. ethanol). 4 PES is suitable for solutions only containing up to 30% MeOH. 5 A ccording to the bacterial challenge test (BCT) with  1 × 107 cfu/cm2 Brevundimonas diminuta. Non-sterile RC Minisart® types are optimized for sample preparation and are not suitable for sterile filtration according to the bacteria challenge test. All other non-sterile Minisart® types with 0.2µm pore size can be sterilized by autoclaving or EO before use for sterile filtration. 6 For sterile packs ACK.
Minisart® Standard Syringe Filters are not for medical use.

72

Filtration DevCicheasp teMr inisart® Syringe Filters

Sample Preparation for Chromatography

Ordering Information

Minisart® RC (Regenerated Cellulose)

 in mm|EFA1

Membrane Housing

25mm

RC

PP

25mm

RC

PP

25mm

RC

PP

25mm

RC

PP

25mm

RC

PP

25mm

RC

PP

25mm

RC

PP

15mm

RC

PP

15mm

RC

PP

15mm

RC

PP

15mm

RC

PP

15mm

RC

PP

4mm

RC

PP

4mm

RC

PP

4mm

RC

PP

4mm

RC

PP

Pore Size Connector Outlet

0.2µm

Male Luer Slip

0.2µm

Male Luer Slip

0.2µm

Male Luer Slip

0.2µm

Male Luer Slip

0.45µm Male Luer Slip

0.45µm Male Luer Slip

0.45µm Male Luer Slip

0.2µm

Male Luer Slip

0.2µm

Male Luer Slip

0.2µm

Male Luer Slip

0.45µm Male Luer Slip

0.45µm Male Luer Slip

0.2µm

Male Luer Slip

0.2µm

Male Luer Slip

0.45µm Male Luer Slip

0.45µm Male Luer Slip

Color|Printing White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed Blue Tray Blue Tray Yellow Tray Yellow Tray

Sterile* Yes No No No No No No Yes No No No No No No No No

Qty./Pkg. 50 50 200 500 50 200 500 50 50 500 50 500 50 500 50 500

Order No. 17764--------ACK 17764----------K 17764----------S 17764----------Q 17765----------K 17765----------S 17765----------Q 17761--------ACK 17761----------K 17761----------Q 17762----------K 17762----------Q 17821----------K 17821----------Q 17822----------K 17822----------Q

Minisart® SRP (Hydrophobic PTFE)

25mm

PTFE

PP

25mm

PTFE

PP

25mm

PTFE

PP

25mm

PTFE

PP

25mm

PTFE

PP

25mm

PTFE

PP

25mm

PTFE

PP

25mm

PTFE

PP

15mm

PTFE

PP

15mm

PTFE

PP

15mm

PTFE

PP

15mm

PTFE

PP

15mm

PTFE

PP

15mm

PTFE

PP

15mm

PTFE

PP

15mm

PTFE

PP

15mm

PTFE

PP

4mm

PTFE

PP

4mm

PTFE

PP

4mm

PTFE

PP

0.2µm 0.2µm 0.2µm 0.2µm 0.2µm 0.45µm 0.45µm 0.45µm 0.2µm 0.2µm 0.2µm 0.2µm 0.2µm 0.45µm 0.45µm 0.45µm 0.45µm 0.2µm 0.45µm 0.45µm

Male Luer Slip Male Luer Slip Male Luer Slip Male Luer Slip Hose Barb Male Luer Slip Male Luer Slip Male Luer Slip Male Spike Male Spike Male Luer Slip Male Luer Slip Male Luer Slip Male Spike Male Spike Male Luer Slip Male Luer Slip Male Luer Slip Male Luer Slip Male Luer Slip

White, Printed

Yes

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

Yes

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

Blue Tray

No

Yellow Tray

No

Yellow Tray

No

50 50 200 500 500 50 200 500 50 500 50 50 500 50 500 50 500 500 50 500

S7575------FXOSK 17575----------K 17575----------S 17575----------Q 1757A----------Q 17576----------K 17576----------S 17576----------Q 17558----------K 17558----------Q 17573--------ACK 17573----------K 17573----------Q 17559----------K 17559----------Q 17574----------K 17574----------Q 17844----------Q 17820----------K 17820----------Q

Filtration Devices Minisart® Syringe Filters

73

Minisart® NY (Nylon) and NY25 Plus (Glass Fiber 0.7µm2 + Nylon)

 in mm|EFA1

Membrane Housing Pore Size Connector Outlet

25mm

Nylon

PP

0.2µm

Male Luer Slip

25mm

Nylon

PP

0.2µm

Male Luer Slip

25mm

Nylon

PP

0.45µm Male Luer Slip

25mm

Nylon

PP

0.45µm Male Luer Slip

15mm

Nylon

PP

0.2µm

Male Luer Slip

15mm

Nylon

PP

0.2µm

Male Luer Slip

15mm

Nylon

PP

0.45µm Male Luer Slip

15mm

Nylon

PP

0.45µm Male Luer Slip

25mm

GF+Nylon

PP

0.2µm

Male Luer Slip

25mm

GF+Nylon

PP

0.2µm

Male Luer Slip

25mm

GF+Nylon

PP

0.45µm Male Luer Slip

25mm

GF+Nylon

PP

0.45µm Male Luer Slip

Color|Printing White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed White, Printed

Sterile* Qty./Pkg. Order No.

Yes

50

17845--------ACK

No

500

17845----------Q

Yes

50

17846--------ACK

No

500

17846----------Q

No

50

1776B----------K

No

500

1776B----------Q

No

50

1776C----------K

No

500

1776C----------Q

No

50

1784B----------K

No

500

1784B----------Q

No

50

1784C----------K

No

500

1784C----------Q

Minisart® PES (Polyethersulfone) Aqueous Filtration

15mm

PES

PP

0.22m

15mm

PES

PP

0.22m

Male Luer Slip Male Luer Slip

White White

Yes

50

No

500

1776D--------ACK 1776D----------Q

Minisart® PES- (Hydrophobic PES) Venting & Gas Filtration, Gamma Stable

25mm

PES

PP

0.2m

Male Luer Slip

25mm

PES

PP

0.2m

Male Luer Slip

25mm

PES

PP

0.2m

Hose Barbs3

25mm

PES

PP

0.2m

Hose Barbs3

White, Printed

No

White, Printed

No

White, Printed

No

White, Printed

No

* Sterile Minisart® syringe filters are individually packaged. If not stated otherwise, Minisart® units have been sterilized by ethylene oxide. Non-presterilized Minisart® units: RC, PTFE and nylon can be sterilized by autoclaving at 121°C for 30min. or by using ethylene oxide (EO).
1 Diameter of EFA ­ Effective Filtration Area 2 0.7µm = GF particle retention  pore size! 3 Hose barbs, inlet and outlet, stepped 4.4­6 mm diameter
Minisart® Standard Syringe Filters are not for medical use.

For technical product specifications, please see page 70.

50 500 50 500

1757H----------K 1757H----------Q 1757G----------K 1757G----------Q

74
0.1 0.45 0.22 Minisart® High Flow with PES
5.0 1.2 0.8 0.65 0.45 0.2 Minisart® NML with (SF)CA
0.2 Minisart® HY with PTFE

Filtration Devices Minisart® Syringe Filters
Minisart® NML Standard Syringe Filter Clarification and Sterilization by Filtration

Filtration is the Optimal Method for Clarification and Sterilization of Liquids and Gases Sterilization by filtration is the fastest method for removal of bacterial cells from liquids, while minimizing the effects on ingredients. Minisart® NML with (surfactant-free) cellulose acetate (SF)CA is the best choice for all aqueous solutions with a pH of 4 to 8. It combines fast flow rates and is available in many d ifferent pore sizes ­ also for the removal of larger particles. Minisart® High Flow with polyethersulfone (PES) is optimal for delivering the highest flow rates and for a broad pH compatibility range from 1 to 13. Due to the asymmetric membrane structure, the PES surface almost behaves like a prefilter.

Both Minisart® types ­ NML and High Flow ­ are available pre-sterilized by ethylene oxide (EO) or gamma irradiation. Hydrophobic PTFE filters like Minisart® SRP are suitable for venting purposes and are additionally available in special formats with activated carbon.

---Minisart® Features Largest effective filtration area (EFA) of 6.2cm2 Low adsorption
High flow rate

---High total throughput
Low hold-up volume Gamma-irradiated or EO-sterilized

28mm EFA 33mm housing diameter (for NML and High Flow)

75

76

Filtration Devices Minisart® Syringe Filters

Minisart® Standard Syringe Filters with MBS Housing

Specifications

Minisart® High Flow|NML|NML Plus with 28mm accessible membrane filtration area diameter, 150µL hold-up volume1 Minisart® HY|Acticosart with 26mm accessible membrane filtration area diameter, 150µL hold-up volume1 Minisart® Air with 15mm accessible membrane filtration area diameter, 100µm hold-up volume1

Housing material

Methacrylate butadiene styrene (MBS)

Membranes

High Flow: PES = Polyethersulfone NML: (SF) CA = (Surfactant-free) Cellulose Acetate NML Plus: (SF) CA = (Surfactant-free) Cellulose Acetate HY|Acticosart|Air: Hydrophobic PTFE = Polytetrafluoroethylene

Glass fiber prefilter

NML Plus: Binder-free GF, 0.7µm particle retention

Max. operating pressure

High Flow: 6.0bar|87psi NML, NML Plus, HY, Air: 4.5bar|65psi Acticosart: 1bar|14.5psi

Housing burst pressure

7bar|102psi (not determined for Acticosart)

Max. temperature

60°C

Sterilization

Non-sterile Minisart® High Flow, NML and NML Plus can be or sterilized by ethylene oxide (EO) or by gamma irradiation. Non-sterile Minisart® HY, Acticosart, Air* can be sterilized by ethylene oxide (EO).

Minisart® Membrane Types

PES 0.1µm

PES 0.2µm

PES

SFCA

0.45µm 0.2µm

SFCA

CA

CA

0.45µm 0.65µm 0.8µm

CA 1.2µm

CA 5.0µm

Non-sterile packages:

K

500 (Q, HYQ), 1000 (R),

sterile packs: individually packaged:

50 (K, GUK, HYK, HNK)

K |

K |

K |

K |

K

GUK |

GUK |

GUK |

GUK |

Q

Q

Q

Q

K | GUK | Q

K | Q

K | Q

Bubble point ()

With water With water With water With water With water With water With water With water With water

5.0bar| 3.2bar| 2.0bar| 3.2bar| 2.0bar| 1.3bar| 0.8bar| 0.7bar| 0.4bar|

73psi

46psi

29psi

46psi

29psi

19psi

12psi

10psi

6psi

Flow Rate for2|3 (mL/min) 28mm  for water at 1bar 15mm  for air at 0.1bar 26mm  for air at 0.1bar

40

140

220

60

160

250

400

500

600

­

­

­

­

­

­

­

­

­

­

­

­

­

­

­

­

­

­

Water penetration point3 ()

­

­

­

­

­

­

­

­

­

Sterile filtration capability4

Yes

Yes

No

Yes

No

No

No

No

No

acc. to the bacteria challenge test

Non-pyrogenic according to the USP

Yes5

Yes5

Yes5

Yes5

Yes5

Yes5

Yes5

Yes5

Yes5

Filtration Devices Minisart® Syringe Filters

77

Minisart® Membrane Types

GF+SFCA GF+SFCA GF+CA

0.2µm

0.45µm 1.2µm

GF 0.7µm

PTFE 0.2µm

PTFE 1.0µm

Acticosart PTFE (Air) 0.2µm

Non-sterile packages:

K | Q

K | Q

Q

500 (Q, HYQ), 1000 (R),

sterile packs: individually packaged,

50 (K, GUK, HYK, HNK)

K | Q

K | Q

HYQ

Q

Q | HNK

Bubble point ()

With water With water With water With water With ethanol With ethanol With ethanol With ethanol

3.2bar|

2.0bar|

0.7bar|

0.5bar| 1.4bar|

0.5bar|

0.9bar|

1.0bar|

46psi

29psi

10psi

7psi

20psi

7psi

13psi

14psi

Flow rate for 2|3 (mL/min) 28mm  for water at 1bar 15mm  for air at 0.1bar 26mm  for air at 0.1bar

60

160

350

450

­

­

­

­

­

­

­

­

­

­

­

800

­

­

­

­

2,000

4,000

2,300

­

Water penetration point3 ()

­

­

­

­

4.0bar|

1.5bar|

58psi

22psi

Sterile filtration capability4

Yes

No

No

No

Yes

No

according to the

bacteria challenge test

Non-pyrogenic according

Yes5

to the USP

1 Hold-up volume after air purge 2 Hydrophilic membranes can filter dry air or gas but become impermeable to air or gas when wetted! 3 Hydrophobic membranes cannot be wetted with aqueous solutions unless you overcome their water penetration point. 4 A ccording to bacterial challenge test (BCT) with 1×107 cfu/cm2 Brevundimonas diminuta. All non-sterile Minisart® types listed above can be sterilized according to the method recommended in this table. 5 For sterile packs K | GUK *Minisart® Air can be sterilized by Gamma irradiation according to the following parameters: Range 25 ­ 40 kGy (validated with 50 kGy).
Standard Minisart® Syringe Filters are not for medical use.

N.a. N.a.

3.2bar| 44psi
Yes

78

Preparation of Aqueous Liquids

Filtration Devices Minisart® Syringe Filters

Ordering Information

Minisart® High Flow (PES ­ Polyethersulfone)

 in mm|EFA1

Membrane Housing

28mm

PES

MBS

28mm

PES

MBS

28mm

PES

MBS

28mm

PES

MBS

28mm

PES

MBS

28mm

PES

MBS

28mm

PES

MBS

28mm

PES

MBS

28mm

PES

MBS

28mm

PES

MBS

28mm

PES

MBS

Pore Size Connector Outlet

0.1µm

Male Luer Lock

0.22µm Male Luer Lock

0.22µm Male Luer Lock

0.22µm Male Luer Slip

0.22µm Male Luer Lock

0.22µm Male Luer Slip

0.45µm Male Luer Lock

0.45µm Male Luer Lock

0.45µm Male Luer Slip

0.45µm Male Luer Slip

0.45µm Male Luer Slip

Color|Printing Dark Red Royal Blue Royal Blue Royal Blue Royal Blue Royal Blue Amber Amber Amber Amber Amber

Sterile* Yes Yes# Yes Yes No No Yes No Yes# Yes No

Qty./Pkg. Order No.

50

16553----------K

50

16532--------GUK

50

16532----------K

50

16541----------K

500

16532----------Q

500

16541----------Q

50

16537----------K

500

16537----------Q

50

16533--------GUK

50

16533----------K

500

16533----------Q

Minisart® NML ((SF)CA ­ (Surfactant-free) Cellulose Acetate)

28mm

SFCA

MBS

0.2µm

Male Luer Lock

28mm

SFCA

MBS

0.2µm

Male Luer Lock

28mm

SFCA

MBS

0.2µm

Male Luer Lock

28mm

SFCA

MBS

0.2µm

Male Luer Slip

28mm

SFCA

MBS

0.2µm

Male Luer Slip

28mm

SFCA

MBS

0.45µm Male Luer Lock

28mm

SFCA

MBS

0.45µm Male Luer Lock

28mm

SFCA

MBS

0.45µm Male Luer Lock

28mm

SFCA

MBS

0.45µm Male Luer Slip

28mm

SFCA

MBS

0.45µm Male Luer Slip

28mm

CA

MBS

0.65µm Male Luer Slip

28mm

CA

MBS

0.8µm

Male Luer Lock

28mm

CA

MBS

0.8µm

Male Luer Lock

28mm

CA

MBS

0.8µm

Male Luer Lock

28mm

CA

MBS

1.2µm

Male Luer Lock

28mm

CA

MBS

1.2µm

Male Luer Lock

28mm

CA

MBS

5µm

Male Luer Lock

28mm

CA

MBS

5µm

Male Luer Lock

Blue Blue Blue Blue Blue Yellow Yellow Yellow Yellow Yellow Pink Green Green Green Red Red Brown Brown

Yes

50

Yes#

50

No

500

Yes

50

No

500

Yes

50

Yes#

50

No

500

Yes

50

No

500

Yes

50

Yes

50

Yes#

50

No

500

Yes

50

No

500

Yes

50

No

500

S6534------FMOSK S6534------FMGUK S6534------FM--Q S7597------FXOSK S7597------FX--Q S6555------FMOSK S6555------FMGUK S6555------FM--Q S7598------FXOSK S7598------FX--Q 16569----------K 16592----------K 16592--------GUK 16592----------Q 17593----------K 17593----------Q S7594------FMOSK 17594----------Q

Filtration Devices Minisart® Syringe Filters

79

Minisart® NML Plus (Glass Fiber 0.7µm2 + SFCA)

 in mm|EFA1 Membrane Housing Pore Size

28mm

GF+SFCA

MBS

0.2µm

28mm

GF+SFCA

MBS

0.2µm

28mm

GF+SFCA

MBS

0.45µm

28mm

GF+SFCA

MBS

0.45µm

28mm

GF+CA

MBS

1.2µm

28mm

GF

MBS

0.7µm2

28mm

GF

MBS

0.7µm2

Connector Outlet Male Luer Lock Male Luer Lock Male Luer Lock Male Luer Lock Male Luer Lock Male Luer Lock Male Luer Lock

Color|Printing Blue Blue Yellow Yellow Red White White

Sterile* Yes No Yes No No No No

Qty./Pkg. Order No.

50

17823----------K

500

17823----------Q

50

17829----------K

500

17829----------Q

500

17825----------Q

50

17824----------K

500

17824----------Q

Minisart® HY (hydrophobic PTFE), for Venting and Gas Filtration

26mm

PTFE

MBS

0.2µm

Male Luer Lock

26mm

PTFE

MBS

1µm

Male Luer Lock

26mm

PTFE

MBS

0.2µm

Male Luer Lock

Clear Clear Clear

Yes

50

No

500

No

500

S6596------FMOSK 1659A--------HYQ S6596------FM--Q

Minisart® High Flow (PES ­ Polyethersulfone) Aqueous Filtration

28mm

PES

MBS

0.1µm

Male Luer Lock

Dark Red

Yes

50

16553----------K

Minisart® Air (Hydrophobic PTFE) Venting

15mm

PTFE

MBS

15mm

PTFE

MBS

0.2µm 0.2µm

Male Luer Slip

Yellow

Male Luer Slip + Needle Yellow

No

500

1751A----------Q

No

500

1751A----------Q

Minisart® Acticosart with Dome Reservoir + Hydrophobic PTFE Venting & Ultracleaning of Gases

26mm

Active carbon MBS

0.45µm Male Luer Slip

Blue

No

500

17840----------Q

* Sterilized Minisart® units are individually packaged. If not stated otherwise, Minisart® are sterilized by ethylene oxide. #-mark indicates sterilization by gamma irradiation. Non-presterilized Minisart® units: High Flow, NML, NML Plus and HY can be sterilized by ethylene oxide; High Flow, NML and NML Plus can also be sterilized by gamma irradiation
1 Diameter of EFA ­ Effective Filtration Area 2 0.7µm = GF particle retention  pore size!
Minisart® Standard Syringe Filters are not for medical use.

For technical product specifications, please see page 76.

80 5.0 0.45 0.2 0.2

Filtration Devices Minisart® Syringe Filters
CE-Minisart® Syringe Filters
For medical use ­ Sterile Filtration and Sterile Venting The medical device CE-Minisart® NML and Ophthalsart with (surfactant-free) cellulose acetate ((SF)CA), and CE-Minisart® HY and SRP with hydrophobic PTFE are frequently used for sterile filtration and | or clarification of aqueous and oily liquids and other medical applications. CE-Minisart® NML with a 5 µm cellulose acetate (CA) membrane removes particulates or coagulates offering high total throughput under sterile conditions. Hydrophobic PTFE filters are suitable for venting purposes. All CE-Minisart® filters are intended to be used in a laboratory environment before use for patient care.
---Minisart® Features
Low adsorption Gamma-irradiated or EO-sterilized Biocompatible acc. to ISO 10993-1

Filtration Devices Minisart® Syringe Filters

81

CE-Minisart® Syringe Filters

Specifications

CE-Minisart® NML / Ophthalsart with 28mm accessible membrane filtration diameter,  150µL hold-up volume1 CE-Minisart® HY with 26mm accessible membrane filtration diameter,  200µL hold-up volume1 CE-Minisart® SRP with 25mm accessible membrane filtration diameter,  200µL hold-up volume1

Housing material

NML/Ophthalsart/HY: Methacrylate butadiene styrene (MBS) SRP: Polypropylene (PP)

Membranes

NML /Ophthalsart: (SF)CA = (Surfactant-free) Cellulose Acetate NML (5µm): CA = Cellulose Acetate HY: Hydrophobic PTFE = Polytetrafluoroethylene SRP: Hydrophobic PTFE = Polytetrafluoroethylene

Max. operating pressure

4.5bar|65psi

Housing burst pressure

7bar|102psi

Max. temperature

60°C

Sterilization

Non-sterile Minisart® NML can be sterilized by ethylene oxide (EO) or gamma irradiation. Non-sterile Minisart® HY can be sterilized by ethylene oxide (EO)

Minisart® type with regards to membrane

SFCA 0.2µm

Non-sterile packages: 500 (Q, HYQ), sterile packs: individually packaged: 50 (K, GUK, HYK, ACK)

K | GUK | Q

Bubble point ()

With water 3.2bar| 46psi

SFCA 0.45µm
K | GUK | Q
With water 2.0bar| 29psi

CA 5.0µm K
With water 0.4bar| 6psi

PTFE 0.2µm HYK | HYQ
With ethanol 1.4bar| 20psi

PTFE 0.2µm ACK
With ethanol 1.1bar| 16psi

Flow Rate for2 (mL/min)

28mm  for water at 1bar

60

25mm  with ethanol at 1 bar

­

25mm  for air at 0.1bar

­

26mm  for air at 0.1bar

­

160

600

­

­

­

­

­

­

­

­

­

2,000

Water penetration point2 ()

­

­

­

4.0bar|

58psi

Sterile filtration capability3

Yes

No

No

Yes

acc. to the bacteria challenge test

Non-pyrogenic

Yes

Yes

Yes

Yes

Biocompatible

acc. to ISO 10993-1

1 Hold-up volume after air purge 2 Hydrophobic membranes cannot be wetted with aqueous solutions unless you overcome their water penetration point. 3 A ccording to the bacterial challenge test (BCT) with  1×107 cfu/cm2 Brevundimonas diminuta. All non-sterile Minisart® types listed above can be sterilized according to the sterilization recommendation in this table.

­ 60 1,800 ­
4.0bar| 58psi Yes
Yes

82

Filtration Devices Minisart® Syringe Filters

CE-Minisart® Syringe Filters for Medical Use

Ordering Information

Minisart® NML ((SF)CA ­ (Surfactant-free) Cellulose Acetate) Aqueous Filtration

 in mm|EFA1

Membrane Housing Pore Size Connector Outlet

28mm

SFCA

MBS

0.2µm

Male Luer Lock

28mm

SFCA

MBS

0.2µm

Male Luer Lock

28mm

SFCA

MBS

0.2µm

Male Luer Lock

28mm

SFCA

MBS

0.2µm

Male Luer Slip

28mm

SFCA

MBS

0.2µm

Male Luer Slip

28mm

SFCA

MBS

0.45µm Male Luer Lock

28mm

SFCA

MBS

0.45µm Male Luer Lock

28mm

SFCA

MBS

0.45µm Male Luer Lock

28mm

SFCA

MBS

0.45µm Male Luer Slip

28mm

SFCA

MBS

0.45µm Male Luer Slip

28mm

CA

MBS

5µm

Male Luer Lock

Color|Printing Blue Blue Blue Blue Blue Yellow Yellow Yellow Yellow Yellow Brown

Sterile* Yes Yes# No Yes No Yes Yes# No Yes No Yes

Qty./Pkg. Order No.

50

16534----------K*

50

16534--------GUK*

500

16534----------Q*

50

17597----------K *

500

17597----------Q*

50

16555----------K*

50

16555--------GUK*

500

16555----------Q*

50

17598----------K*

500

17598----------Q*

50

17594----------K*

Minisart® Ophthalsart (SFCA ­ Cellulose Acetate) Aqueous Filtration

28mm

SCFA

MBS

0.2µm

Male Luer Slip

Pink

Yes

50

17528----------K*

Minisart® HY (Hydrophobic PTFE), for Venting and Gas Filtration

26mm

PTFE

MBS

0.2µm

Male Luer Lock

26mm

PTFE

MBS

0.2µm

Male Luer Lock

26mm

PTFE

MBS

0.2µm

Male Luer Locka

Clear Clear Clear

Yes

50

No

500

No

500

16596--------HYK* 16596--------HYQ* 16599--------HYQ*

Minisart® SRP (Hydrophobic PTFE) Venting & Gas Filtration

25mm

PTFE

PP

0.2µm

Male Luer Slip

White, Printed Yes

50

* Article numbers are only available in: EU/EEA and in registered countries. ** Sterilized Minisart® units are individually packaged. If not stated otherwise, Minisarts are sterilized by ethylene oxide.
#-mark indicates sterilization by gamma irradiation Non-presterilized Minisart® units: (SF)CA can be sterilized by ethylene oxide or gamma irradiation. PTFE can be sterilized by ethylene oxide. a Connector inlet: Male Luer Slip (all other Minisart® have Female Luer Lock inlet(s)). 1 Diameter of EFA ­ Effective Filtration Area

For technical product specifications, please see page 81.

17575--------ACK*


Adobe InDesign 15.0 (Windows) Adobe PDF Library 15.0