RESIDENTIAL PRODUCT SPECIFICATIONS

GAS FURNACES
ML193DFE
MERIT® SERIES Downflow - High Efficiency Blower
Bulletin No. 210868 April 2021
Supersedes July 2020

AFUE - 93% Input - 44,000 to 88,000 Btuh Nominal Add-on Cooling - 1.5 to 4 Tons
MODEL NUMBER IDENTIFICATION
ML 1 93 DF 070 X E 36 B

Unit Type ML = Merit® Series
Stages 1 = One-Stage
AFUE 93 = 93%
Configuration DF = Downflow
Nominal Gas Heat Input 045 = 44,000 Btuh 070 = 66,000 Btuh 090 = 88,000 Btuh

1 Cabinet Width B = 17-1/2 in. C = 21 in.
Nominal Add-On Cooling Capacity 36 = 1.5 - 3 tons 48 = 2.5 - 4 tons
Blower E = High Efficiency Constant Torque Blower Motor
Low NOx X = Units meet California Nitrogen Oxides Standard (40 ng/J)
1 D ownflow indoor coils with the same letter designation will physically match the furnace supply air opening.

FEATURE HIGHLIGHTS

1. Lennox Duralok PlusTM Heat Exchanger 2. Secondary Heat Exchanger 3. Inshot Burners 4. Gas Control Valve 5. Combustion Air Inducer 6. SureLight® Integrated Furnace Control 7. Power SaverTM Constant Torque Blower 8. Insulated Cabinet 9. Safety Interlock Switch 10. Gas Piping And Electrical Inlets

G

I H

C

J

F

B

E

K D

CONTENTS
Approvals and Warranty .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3 Blower Data .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  19 Dimensions - Furnace/Coil Combined Dimensions .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  15 Dimensions - Optional Accessories  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14 Dimensions - Optional Accessories - Venting .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  16 Dimensions - Unit .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  13 Features .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  3 Gas Heat Accessories  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  10 High Altitude Derate  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  10 Installation Clearances  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  8 Optional Accessories  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9 Specifications .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  8 Vent Lengths  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  11 Vent Lengths - Uninsulated Exhaust Pipe In Unconditioned Space  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  10

ML193DFE / Page 2

APPROVALS AND WARRANTY
APPROVALS · AHRI Certified · Tested and rated according to US DOE test procedures and FTC labeling regulations · Approved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/J · ENERGY STAR® units are certified only in the U.S. South in certain states and are designed to use less energy, help save
money on utility bills, and help protect the environment · ISO 9001 Registered Manufacturing Quality System · Blower data from unit tests conducted in Lennox Laboratory air test chamber
California Only · These furnaces do not meet the South Coast Air Quality Management District (SCAQMD) Rule 1111 and San Joaquin Valley Air Pollution Control District (SJVAPCD) Rule 4905 NOx emission limit (14 ng/J) and cannot be installed within the SCAQMD and SJVAPCD areas · These furnaces are approved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/J
WARRANTY · Duralok PlusTM Aluminized Steel Heat Exchanger:
· Limited twenty year in residential applications · Limited ten years in non-residential applications · All other covered components: · Limited five years in residential installations · Limited one year in non-residential installations NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details.

FEATURES
APPLICATIONS · Input capacities of 44,000, 66,000 and 88,000 Btuh. · Energy efficiency (AFUE) 93%. · Lennox add-on indoor coils, high-efficiency air cleaners
and humidifiers can easily be added to furnace. · Shipped factory assembled with controls installed and wired. · Each unit factory test operated to ensure proper operation.
HEATING SYSTEM
B Lennox Duralok PlusTM Heat Exchanger Assembly
· Lennox developed heat exchanger assembly consists of primary heat exchanger and secondary condenser coil assembly.
· Main multi-pass crimped seam design clamshell type heat exchanger.
· Constructed of heavy-gauge, aluminized steel. · Designed for normal expansion and contraction with
maximum efficiency and minimum resistance to air flow.
C · Secondary heat exchanger condenser coil constructed
of aluminum fins fitted to stainless steel tubes. · Coil is factory tested for leaks.

· Condensate drain header box assembly located on front of coil.
· Compact size of complete heat exchanger assembly permits low overall design of furnace cabinet.
· Heat exchanger assembly has been laboratory life cycle tested in excess of industry standards.
Lennox Designed Header Box · Header box on end of condenser coil collects flue
condensate for disposal through condensate drains.
· The drains are located on each side of the cabinet for easy field installation of condensate drain trap.
· Only one drain is used, the other drain is sealed.
· Condensate drain trap is included with unit for field installation.

ML193DFE / Page 3

FEATURES
HEATING SYSTEM (continued)
Lennox Designed Flue Condensate Trap Assembly · Field installed outside the conditioned air stream
· Assembly can be mounted on either side of cabinet in upflow applications
· Assembly is mounted below the cabinet in horizontal applications
· Can also be mounted remotely (up to 5 ft. away) from unit
· See Dimension Drawing and Installation Instructions
· 90° street elbow furnished for ease of drain trap installation
· Drain connection can be made with field provided PVC pipe or PVC coupling
· Drain cap on trap allows easy cleaning and winterizing
D Inshot Burners
· Aluminized steel inshot burners provide efficient, troublefree operation
· Burner venturi mixes air and gas in correct proportion for proper combustion
· Burner assembly can be removed from the unit as a single component for ease of service
SureLight® Hot Surface Ignitor · Tough, reliable, long-life, trouble-free performance
· Silicon nitride ignitor
· Cemented to steatite block for protection against current leakage
· Ignition leads are constructed of nickel plated copper and are enclosed in high temperature Teflon® insulation for dependable operation
E Gas Control Valve
· 24 volt redundant combination gas control valve combines manual shut off switch (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control
Flame Rollout Switches (2) · Factory installed on the front of the burner box
· Switch provides protection from abnormal operating conditions
· Manual reset
Limit Control · Automatic reset, primary limit is accurately located on
header box on all units
F Combustion Air Inducer
· Shaded pole heavy duty blower prepurges heat exchanger and safely vents flue products
· Operates only during heating cycle
Pressure Switch · Proves Combustion Air Inducer operation before
allowing gas valve to open

Optional Accessories
High Altitude Orifice Kits · Required on all units for proper operation at altitudes
from 7501 to 10,000 ft.
· Kits are available for natural gas and LPG/propane
High Altitude Pressure Switch Kit · Required for proper unit operation on installations above
4500 ft.
Natural Gas to LPG/Propane Conversion Kit · Required for field changeover from natural gas to LPG/
Propane
LPG/Propane to Natural Gas Conversion Kit · Required for field changeover from LPG/Propane to
natural gas
Muffler (US Only) · Significantly reduces outdoor operating sound levels
· Two-inch diameter muffler is optional for all models
· Installed vertically in the exhaust piping
· See Optional Accessory Dimension Drawing
DIRECT VENT / NON-DIRECT VENT SEALED COMBUSTION SYSTEM
· Furnace features a "sealed combustion" system and can be installed in either Direct Vent or Non-Direct applications
· In Direct Vent applications, combustion air is supplied from outdoors and flue gases are discharged outdoors
· In Non-Direct Vent applications, combustion air is supplied from indoors and flue gases are discharged outdoors
NOTE - Lennox has approved the use of DuraVent® PolyPro® and Centrotherm InnoFlue® manufactured vent pipe and terminations as an alternative to PVC vent pipe. Must be ordered separately. Tested and listed to the ULC S636 standard in Canada.
· The polypropylene venting system must follow the uninsulated and unconditioned space vent lengths listed in the table on Page 10
· Refer to the Installation Instructions for additional details

ML193DFE / Page 4

FEATURES

DIRECT VENT / NON-DIRECT VENT SEALED COMBUSTION SYSTEM (continued)

Roof Termination Flashing Kit · For vertical venting through a roof

Flue Coupling · Assists with exhaust flue piping connection and servicing

· 2 or 3 inch kit contains two neoprene rubber roof flashings

· Includes flexible one 2-inch rubber coupling and two adjustable bands
· Approved for all Lennox 90% furnaces
Vent Termination Kits · Facilitates installation of combustion air intake pipe and
flue exhaust pipe
· Refer to venting table in this bulletin to determine pipe size needed and proper termination kit required
· See Optional Accessories table and dimension drawings
Concentric Termination Kit - Direct Vent Applications

· Vent pipe and insulation not furnished
· Flashing Kit can also be used with Concentric Vent Termination Kits used in vertical venting rooftop applications
CONTROLS
G SureLight® Integrated Furnace Control
· Contains all necessary controls and relays to operate furnace
· Combustion air inducer is operated by the integrated furnace control

· 2 or 3 inch kit contains concentric termination assembly, reducer bushing and 45° elbow
· 2 inch kit for -030-045-070 models contains an outdoor exhaust accelerator
· Kit requires single hole penetration of roof or wall for installation
· Roof Termination Flashing Kit is available for use with 2 inch Kits
· CSA certified
Flush-Mount Termination Kit
· Kit contains flush-mount termination, accelerator, mounting template and hardware
· Kit may be used with 2, 2-1/2 or 3 in. pipe
Wall Assembly Termination Kits
Close Couple (US Only) - Direct Vent Applications
· 2 or 3 inch kit consists of close-couple, side-by-side PVC piping with galvanized steel wall cover plate
· Seals and isolates intake and exhaust piping penetration of wall
· Piping spacing and length is sized for proper wall installations
· CSA certified

· Prior to ignition, a pre-purge cycle for 15 seconds is initiated
· After the main burners are turned off, a post-purge cycle for 5 seconds is run
· Flame sensor assures safe and reliable operation
· Should loss of flame occur, the integrated furnace control will initiate 4 re-attempts at ignition before locking out unit operation for 60 minutes
· Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service
· Fan control consists of adjustable blower timed-off delay (60, 90, 120, 180 seconds - factory setting 90 seconds) and fixed blower timed-on delay (30 seconds heating, 2 seconds cooling)
· For air-conditioning applications, blower is automatically energized on thermostat demand for cooling
· Two accessory terminals furnished for additional power supply requirements for 120 volt (less than 1 amp) power humidifiers and powered air cleaners
· One additional terminal is furnished for power supply requirements for 24V (less than 0.5 amp) low voltage accessories

Close Couple WTK (Canada Only) - Direct Vent Applications
· 2 or 3 inch kit contains one insulated faceplate, one insulated exhaust pipe, elbow and fittings

· Ignition control has a single red LED to indicate status and as an aid in troubleshooting
· Last ten codes are stored in non-volatile memory (accessible by recall button on control) for servicing

NOTE - Maintain a maximum of 6 inches between the inlet and outlet openings in the installation of the pipes.

24 Volt Transformer (40VA) · Fuse wired in series

· Furnished and factory installed in control box

Field Wiring Make-Up Box · Furnished for line voltage wiring
· Factory installed internally on left side of furnace
· Box may be installed internally or externally on either side of furnace

ML193DFE / Page 5

FEATURES

CONTROLS (continued)
Optional Accessories
iComfort® M30 Smart Wi-Fi Thermostat · Wi-Fi-enabled, electronic 7-day, universal, multi-stage,
programmable, touchscreen thermostat
· 4 Heat/2 Cool
· Auto-changeover
· Dual-fuel control with optional outdoor sensor
· Controls dehumidification during cooling mode and humidification during heating mode

Thermostat · Thermostat is not furnished with unit
· See Lennox Price Book for selection
Blower Relay Kit (For Use With Two-Stage Outdoor Units) · Allows furnace blower speed changes when matched
with two-stage air conditioners or heat pumps
Furnace Twinning Kit · Required to operate two furnaces simultaneously
· Kit consists of twinning relays, quick connect terminals and mounting hardware
· Used for single-stage heating/single-stage cooling with a single-stage thermostat

· Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol® control, and equipment maintenance reminders
· Easy to read 4.3 in. color touchscreen (measured diagonally)

Night Service Kit · Contains most commonly used service parts:
· Furnace Control · Igniter · Flame Sensor

· LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required)

· Gas Valve · Transformer · Service Manual

· Smooth Setback Recovery starts system early to achieve setpoint at start of program period

BLOWER · Direct drive blower

· Compressor short-cycle protection (5 minutes)

· Statically and dynamically balanced

· Up to four separate schedules are available plus

· Resiliently mounted

Schedule IQTM

· Blower assembly easily removed for servicing

· One-Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away

H

Power SaverTM Constant Torque Blower Motor

· Smart AwayTM - Uses geo-fencing technology

· DC Brushless Motor

to determine when the homeowner is within a

· High Efficiency Constant Torque

predetermined distance from the home to operate the

· ECM (Electronically Commutated Motor)

system when leaving, away and arriving

· Motor is programmed to provide constant torque at

· Wi-Fi remote monitoring and adjustment through a

each of the selectable speeds

home wireless network for desktop PCs, laptops and apps for smartphones or tablets
· Smart home automation compatible with Amazon Alexa®, Google Assistant and IFTTT
· Service Dashboard features online real-time monitoring

· Motor is controlled by the Integrated Furnace Control
· Blower speeds are easily changed on the integrated furnace control
· See Blower Data tables

of installed iComfort® thermostats

NOTE - See the iComfort® M30 Smart Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information.

Remote Outdoor Temperature Sensor · Used with the iComfort® M30 Smart Thermostat
· Outdoor sensor allows thermostat to display outdoor temperature
NOTE - Sensor is required for the Enhanced Dehumidification Accessory (EDA).

ML193DFE / Page 6

FEATURES
CABINET · Low-profile, narrow width allows easy installation · Heavy-gauge, cold rolled steel construction · Pre-painted cabinet finish · Flanges provided on supply air opening for ease of
plenum connection or alignment with indoor coil
I · Insulated with foil faced insulation on sides and back of
heating compartment · Sealed blower compartment · Complete service access
J · Safety interlock switch automatically shuts off power to
unit when blower compartment access door is remove
K · Gas piping and electrical inlets are provided in both sides
of cabinet
Coil Match-Up · All Lennox downflow indoor coils will physically match
the furnace supply air opening with the same letter designation (A, B, C, D) as in the furnace model number
Low Leakage Cabinet · All models have less than 2% air leakage and meet
ANSI/ASHRAE Standard 193-2010 "Method of Test for Determining the Air Tightness of HVAC Equipment"
Optional Accessories
Condensate Drain Heat Cable Kits · Self-limiting wattage heat cable prevents condensate
drain from freezing in unconditioned areas · Available in 6 or 24 ft. lengths
Crawl Space Vent Drain Kit · Allows venting through a crawl space for downflow
applications · Includes 2 or 3 in. sanitary tee, 2 in. PVC assembly, PVC
boot and clamp · Kit for Canada is certified to ULC S636
Downflow Combustible Flooring Base · Required for heating only units installed on combustible
floors · Not required in add-on cooling applications · See Dimension Drawing

FILTER (not furnished) · Filter and provisions for external mounting must be field
provided
Optional Accessories
Downflow Filter Cabinet · Filter cabinet mounts directly on top of furnace · "B and "C" width cabinets have two filters · Filter rails are furnished · Front access for servicing · Cleanable filter(s) are furnished

ML193DFE / Page 7

SPECIFICATIONS

Gas Heating Performance

Model No. AHRI Reference No.

1 AFUE

ML193DF045XE36B 20556884 93%

ML193DF070XE36B 20556885 93%

ML193DF090XE48C 20556886 93%

Input - Btuh

44,000

66,000

88,000

Output - Btuh

42,000

63,000

84,000

Temperature rise range - °F

30 - 60

40 - 70

45 - 75

Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane

3.5 / 10.0

3.5 / 10.0

3.5 / 10.0

High static - in. w.g.

0.50

0.50

0.50

Connections Intake / Exhaust Pipe (PVC)

2 / 2

2 / 2

2 / 2

in.

Gas pipe size IPS

1/2

1/2

1/2

Condensate Drain Trap (PVC pipe) - i.d.

3/4

3/4

3/4

with furnished 90° street elbow

3/4 slip x 3/4 Mipt

3/4 slip x 3/4 Mipt

3/4 slip x 3/4 Mipt

with field supplied (PVC coupling) - o.d.

3/4 slip x 3/4 MPT

3/4 slip x 3/4 MPT

3/4 slip x 3/4 MPT

Indoor Blower

Wheel nom. dia. x width - in. Motor output - hp

10 x 8 1/2

10 x 8 1/2

10 x 10 3/4

Tons of add-on cooling

1.5 - 3

1.5 - 3

2.5 - 4

Air Volume Range - cfm

335 - 1430

340 - 1415

825 - 1720

Electrical Data

Voltage Blower motor full load amps

120 volts - 60 hertz - 1 phase

6.8

6.8

8.4

Maximum overcurrent protection

15

15

15

Shipping Data

lbs. - 1 package

122

128

151

NOTE - Filters and provisions for mounting are not furnished and must be field provided. 1 Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.

INSTALLATION CLEARANCES

Sides

1 0 inches (0 mm)

Rear

0 inches (0 mm)

Top/Plenum

1 inch (25 mm)

Front

0 inches (0 mm)

Front (service/alcove)

24 inches (610 mm)

Floor

2 Combustible

NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ ANSI-Z223.1) or the National Standard of Canada CAN/CSA-B149.1 "Natural Gas and Propane Installation Code".
NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ANSI-Z223.1) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B149.1.
1 Allow proper clearances to accommodate condensate trap and vent pipe installation.
2 Clearance for installation on combustible floor if Optional Downflow Combustible Flooring Base is installed between furnace and combustible floor. Not required in add-on cooling applications if installed in accordance with local codes or National Fuel Gas Code ANSI-Z223.1 or CAN/CGA-149.1,.2. Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring.

ML193DFE / Page 8

OPTIONAL ACCESSORIES

"B" Width Models

"C" Width Models

CABINET ACCESSORIES Downflow Combustible Flooring Base CONDENSATE DRAIN KITS Condensate Drain Heat Cable
Crawl Space Vent Drain Kit
CONTROLS Blower Relay Kit (for two-stage outdoor units) iComfort® M30 Smart Wi-Fi Thermostat Remote Outdoor Temperature Sensor Twinning Kit DOWNFLOW FILTER KITS 1 Downflow Filter Cabinet

6 ft. 24 ft.
US Canada
No. and Size of filter - in.

11M60
26K68 26K69 51W18 15Z70
85W66 15Z69 X2658 16W72
51W07 (2) 16 x 20 x 1

11M61
26K68 26K69 51W18 15Z70
85W66 15Z69 X2658 16W72
51W08 (2) 16 x 20 x 1

NIGHT SERVICE KIT

Night Service Kit

84W48

84W48

TERMINATION KITS

See Installation Instructions for specific venting information.

Direct Vent

Concentric

US - 2 in.

71M80

69M29

3 in.

- - -

60L46

Canada - 2 in.

44W92

44W92

3 in.

- - -

44W93

Flush-Mount

US - 2, 2-1/2 or 3 in.

51W11

51W11

Canada - 2, 2-1/2 or 3 in.

51W12

51W12

Wall - Close Couple

US - 2 in.

22G44

- - -

3 in.

44J40

44J40

Wall - Close Couple WTK

Canada - 2 in.

30G28

- - -

3 in.

81J20

81J20

Roof Termination Flashing Kit (no vent pipe - 2 flashings)

2 in.

15F75

3 in.

44J41

15F75 44J41

VENTING

Flue Coupling

2 in.

17H92

17H92

1 Cleanable polyurethane frame type filter. NOTE - Termination Kits (44W92, 44W93, 30G28, 51W12, 81J20) and Crawl Space Vent Drain Kit (15Z70) are certified to ULC S636 standard for use in Canada only.

ML193DFE / Page 9

GAS HEAT ACCESSORIES

Models

High Altitude Pressure Switch Kit

4501 - 7500 ft. 7501 - 10,000 ft.

045

11U65

11U66

070

11U65

11U66

090

11U65

11U66

Natural Gas to LPG/Propane
Kit
0 - 7500 ft.
11K49
11K49
11K49

LPG/Propane to Natural Gas
Kit
0 - 7500 ft.
73W81
73W81
73W81

Natural Gas High Altitude
Orifice Kit
7501 - 10,000 ft.
73W37
73W37
73W37

LPG/Propane High Altitude
Orifice Kit
7501 - 10,000 ft.
11K44
11K44
11K44

Muffler (US Only)
15Y66 (2-inch) 15Y66 (2-inch) 15Y66 (2-inch)

HIG H ALT IT U DE DERATE
NOTE - U nits may be installed at altitudes up to 10,000 ft. At altitudes above 4501 ft. the unit must be derated to match the manifold pressure information shown below. Units installed at altitudes of 4501 to 10,000 ft. require a pressure switch change. Units installed at altitudes of 7501 to 10,000 ft. require an orifice change. See the Gas Heat Accessories table for ordering information.
NOTE - This is the only permissible derate for these units.
NOTE - In Canada, certification for installations at elevations over 4500 feet is the jurisdiction of local authorities.

Input

Gas

Natural All Sizes
LPG/Propane

0 - 4500 ft.
3.5 10.0

Manifold Pressure in. w.g.

4501 - 5500 ft. 5501 - 6500 ft. 6501 - 7500 ft. 7501 - 10,000 ft.

3.3

3.2

3.1

3.5

9.4

9.1

8.9

10.0

Supply Line Pressure in. w.g.
0 - 10,000 ft.
4.5 13.0
11.0 13.0

VENT LENGTHS - UNINSULATED EXHAUST PIPE IN UNCONDITIONED SPACE

Unit Input Size

1 Winter Design Temperatures

Vent Pipe Diameter

PVC

045

070

090

Maximum Uninsulated Exhaust Vent Length (ft.)

PolyPro InnoFlue

PVC

PolyPro InnoFlue

PVC

PolyPro InnoFlue

1-1/2 in.

25

N/A

25

N/A

N/A

N/A

32 to 21°F

2 in. 2-1/2 in.

18

16

31

28

50

48

13

N/A

24

N/A

42

N/A

3 in.

9

9

18

18

35

35

1-1/2 in.

15

N/A

20

N/A

N/A

N/A

20 to 1°F

2 in. 2-1/2 in.

9

8

18

16

32

29

5

N/A

13

N/A

24

N/A

3 in.

N/A

N/A

8

8

19

19

1-1/2 in.

10

N/A

15

N/A

N/A

N/A

0 to ­20°F

2 in. 2-1/2 in.

5

N/A

12

10

22

19

N/A

N/A

7

N/A

15

N/A

3 in.

N/A

N/A

N/A

N/A

10

10

NOTE - Concentric terminations are equivalent to 5 ft. of straight pipe and should be included when measuring total pipe length. 1 Refer to 99% Minimum Design Temperature table provided in the current edition of the ASHRAE Handbook-Fundamentals. PolyPro® poly-propylene vent pipe is a registered trademark of DuraVent®. Innoflue® is a registered trademark of Centrotherm Eco Systems.

ML193DFE / Page 10

OUTDOOR TERMINATION KIT USAGE

Input Size
045

Vent Pipe Diameter (in.)
1 1-1/2 2
2-1/2 3

Standard Terminations

Flush Mount
Kit

Wall Kit

2 inch

3 inch

51W11 (US) 22G44 (US) 44J40 (US) 5 51W12 (CA) 5 30G28 (CA) 5 81J20 (CA)

4 YES 4 YES 4 YES 4 YES

YES YES YES YES

2 YES 2 YES 2 YES 2 YES

Concentric Terminations

Field Fabricated

Concentric Kit

Exhaust

1-1/2 inch

Accelerator

2 inch

3 inch

Size

71M80 (US) 69M29 (US) 60L46 (US)

Required 5 44W92 (CA) 5 44W92 (CA) 5 44W93 (CA)

1-1/2 in.

3 YES

- - -

- - -

1-1/2 in.

3 YES

- - -

- - -

1-1/2 in.

3 YES

- - -

- - -

1-1/2 in.

3 YES

- - -

- - -

1 1-1/2

4 YES

070

2 2-1/2

4 YES 4 YES

3

4 YES

2

4 YES

090

2-1/2

4 YES

3

4 YES

YES YES YES YES - - - - - - -

2 YES 2 YES 2 YES 2 YES YES YES YES

1-1/2 in. 1-1/2 in. 1-1/2 in. 1-1/2 in.
2 in. 2 in. 2 in.

3 YES 3 YES 3 YES 3 YES
- - - - - - -

- - - - - - - - YES YES YES

- - - - - - - - YES YES YES

NOTE - S tandard Terminations do not include any vent pipe or elbows external to the structure. Any vent pipe or elbows external to the structure must be included in total vent length calculations. See Vent Length Tables.
1 2 inch to 1-1/2 inch reducer required, must be field provided. 2 Requires field provided 1-1/2 in. outdoor exhaust accelerator. 3 Concentric Kits 71M80 and 44W92 include 1-1/2 in. outdoor exhaust accelerator, required when used with 045 and 070 input models. Accelerator is not used with 090
input models. NOTE - When using 1-1/2 in. piping, the pipe must be transitioned to 2 in. pipe when used with the Concentric Kit. 4 Flush Mount Kit 51W11 and 51W12 includes 1-1/2 in. outdoor exhaust accelerator, required when used with all models. NOTE - When using 1-1/2 in. piping, the pipe
must be transitioned to 2 in. pipe when used with the Flush Mount Kit. 5 Termination Kits 30G28, 44W92, 44W93, 51W12 and 81J20 are certified to ULC S636 standard for use in Canada only.

VENT LENGTHS

STANDARD TERMINATION AT ELEVATION 0 - 10,000 ft.

Pipe Size

1-1/2 in.

2 in.

2-1/2 in.

3 in.

Input 045 070 090 045 070 090 045 070 090 045 070 090

1

20

15

N/A

61

46

24

100

80

43

127 127 108

2

15

10

N/A

56

41

19

95

75

38

122 122 103

3

10

N/A N/A

51

36

14

90

70

33

117 117

98

4

N/A N/A N/A 46

31

N/A

85

65

28

112 112

93

No. of

5

90 ELL

6

N/A N/A N/A 41

26

N/A

80

60

23

107 107

88

N/A N/A N/A 36

21

N/A

75

55

18

102 102

83

7

N/A N/A N/A 31

16

N/A

70

50

13

97

97

78

8

N/A N/A N/A 26

11

N/A

65

45

N/A

92

92

73

9

N/A N/A N/A

21

N/A N/A

60

40

N/A

87

87

68

10

N/A N/A N/A

10

N/A N/A

55

35

N/A

82

82

63

CONCENTRIC TERMINATION ELEVATION 0 - 10,000 ft.

Pipe Size

1-1/2 in.

2 in.

2-1/2 in.

3 in.

Input 045 070 090 045 070 090 045 070 090 045 070 090

1

15

10

N/A

53

38

22

90

70

39

111 111 104

2

10

N/A N/A

48

33

17

85

65

34

106 106

99

3

N/A N/A N/A 43

28

12

80

60

29

101 101

94

4

N/A N/A N/A 38

23

N/A

75

55

24

96

96

89

No. of

5

90 ELL

6

N/A N/A N/A 33

18

N/A

70

50

19

91

91

84

N/A N/A N/A 28

13

N/A

65

45

14

86

86

79

7

N/A N/A N/A

23

N/A N/A

60

40

N/A

81

81

74

8

N/A N/A N/A

18

N/A N/A

55

35

N/A

76

76

69

9

N/A N/A N/A

13

N/A N/A

50

30

N/A

71

71

64

10

N/A N/A N/A N/A N/A N/A 45

25

N/A

66

66

59

NOTES - Additional vent pipe and elbows used to terminate vent pipe outside the structure must be included in the total vent length calculation. Intake and exhaust pipes are sized separately. Values in table are for separate intake or exhaust pipe lengths. Both intake and exhaust pipe must be the same size diameter.

ML193DFE / Page 11

VENT LENGTHS (EXHAUST) - VENTILATED ATTIC OR CRAWLSPACE INTAKE AIR - FEET

STANDARD TERMINATION AT ELEVATION 0 - 10,000 ft.

Pipe Size

1-1/2 in.

2 in.

2-1/2 in.

3 in.

Input 045 070 090 045 070 090 045 070 090 045 070 090

1

15

10

N/A

51

36

14

85

65

28

107 107

88

2

10

N/A N/A

46

31

9

80

60

23

102 102

83

3

N/A N/A N/A

41

26

4

75

55

18

97

97

78

4

N/A N/A N/A

36

21

N/A

70

50

8

92

92

73

No. of

5

90 ELL

6

N/A N/A N/A

31

16

N/A

65

45

3

87

87

68

N/A N/A N/A

26

11

N/A

60

40

N/A

82

82

63

7

N/A N/A N/A

21

6

N/A

55

35

N/A

77

77

58

8

N/A N/A N/A

16

1

N/A

50

30

N/A

72

72

53

9

N/A N/A N/A

11

N/A N/A

45

25

N/A

67

67

48

10

N/A N/A N/A

6

N/A N/A

40

20

N/A

62

62

43

NOTES - Additional vent pipe and elbows used to terminate vent pipe outside the structure must be included in the total vent length calculation.

ML193DFE / Page 12

DIMENSIONS - UNIT

9/16 (14)

Flue Condensate Trap Assembly Furnished for external field installation on either side of unit. (See installation instructions for additional information.)

COMBUSTION
7 AIR INTAKE (178)
EXHAUST AIR OUTLET

B

RETURN AIR OPENING

2-1/16 (52)

5 (127)

2-1/4

9/16

(57)

(14)

TOP VIEW

A
B
AIR FLOW

9/16 (14)

1 (25) Front Panel

27-3/4 (705)

19-7/16

9/16

(494)

(14)

33 (838)

2 (51) Either Side GAS PIPING INLET (Either Side)
9-1/8 (232) Right 6-9/16 (167) Left

3/4 (19)

C

Supply Air

3/4 (19)

FRONT VIEW

ELECTRICAL INLET (Either Side)

CONDENSATE TRAP CONNECTION
(Either Side)

9 (229) 6-7/16 (163) Either Side Either Side

19-1/4 Supply

3/4

(489) Air

(19)

SIDE VIEW

Model No.
ML193DF045XE36B ML193DF070XE36B ML193DF090XE48C

A

in.

mm

17-1/2

446

21

533

B

in.

mm

16-3/8

416

19-7/8

505

C

in.

mm

16

406

19-1/2

495

ML193DFE / Page 13

DIMENSIONS - OPTIONAL ACCESSORIES
DOWNFLOW FILTER CABINET
"B AND "C" WIDTH FURNACES (Two Filters)

20-1/2 (521)

17-1/2 (445) "B" Box 21 (533) "C" Box

FILTERS (2)

17-1/2 (445)

FILTER ACCESS DOOR
NOTE: Return Air Opening (W x D) "B" Box 16-1/2 x 19-5/8 (419 x 498)
"C" Box 20 x 19-5/8 (508 x 498)

50-1/2 (1283 )

FURNACE

33 (838)

ML193DFE / Page 14

DIMENSIONS - OPTIONAL ACCESSORIES
DOWNFLOW COMBUSTIBLE FLOORING BASE
1-1/2 (38)

DOWN FLOW FURNACE

1-1/2 (38)

SUPPLY AIR
OPENING 19-13/16 (503)
B

1-1/2 (38)

27-1/4 (692)

21-13/16 (554)

22 (559)

DOWNFLOW COMBUSTIBLE
FLOORING BASE
FLOOR OPENING

Front Of Furnace
A
TOP VIEW

1-1/2 (38)
SIDE VIEW

Cabinet Catalog Width Number

A in. mm

B

11M60 19-9/16 497

C

11M61 23-1/16 586

B

in.

mm

16-9/16 421

20-1/16 510

C

in.

mm

18-3/4 476

22-1/4 565

C

DIMENSIONS - FURNACE/COIL COMBINED DIMENSIONS DOWNFLOW POSITION
Furnace Width

33 (838)
Overall Height
Coil Height

Model Number

Coil Width
in. mm

Furnace Width
in. mm

Coil Height
in. mm

Overall Height
in. mm

CR33-24B-F 17-1/2 446 17-1/2 446 13-1/4 337 46-1/4 1175

CR33-30/36B-F 17-1/2 446 17-1/2 446 16-1/8 410 49-1/8 1248

CR33-30/36C-F 21 533 21 533 16-1/8 410 49-1/8 1248

CR33-48B-F

21 533 17-1/2 446 20 508 53 1346

CR33-48C-F

21 533 21 533 20 508 53 1346

CR33-50/60C-F 24-1/2 622 21 533 23-5/8 600 56-5/8 2276

Coil Width

ML193DFE / Page 15

DIMENSIONS - OPTIONAL ACCESSORIES - VENTING
FLUSH-MOUNT VENT TERMINATION KIT 51W11 (US) or 51W12 (CANADA)

2-3/8 (60)

With 2 or 2-1/2 in. (51 or 64 mm) PVC pipe

Exhaust

Intake

(Behind Plate)

Seal all openings (typical)

With 3 in. (76 mm) PVC pipe

Exhaust

Intake

(Behind Plate)

12 (305) minimum (recommended)

2 (51) PVC pipe

3 (76) PVC pipe

NOTE - PVC pipe and fittings are not furnished When required Use and must be field furnished.
Field Provided
2-1/2 to 2 in. (64 to 51 mm) Coupling

2-1/2 (64) PVC pipe

MUFFLERS 15Y66 - 2-inch

18-3/4 (476)

4-1/2 (114)
(Installed Vertically in the Exhaust Pipe)

ML193DFE / Page 16

DIMENSIONS - OPTIONAL ACCESSORIES - VENTING

CONCENTRIC WALL TERMINATION APPLICATIONS

CONCENTRIC ROOF TERMINATION APPLICATIONS

EXHAUST AIR
INTAKE AIR

OUTSIDE WALL
CLAMP (Not Furnished)

INTAKE AIR EXHAUST AIR

12 (305)
Minimum Above Average
Snow Accumulation

INTAKE AIR

12 (305)
Minimum Above Grade or Average Snow Accumulation

GRADE

CLAMP

FLASHING (Not Furnished)
SHEET METAL STRAP
(Clamp and sheet metal strap must be field installed to support the weight of the termination kit.)

71M80 / 69M29 / 44W92 - 2 inch kits 60L46 / 44W93 - 3 inch kits
See Installation Instructions for additional information.

Note - Field provided reducer may be required to adapt different vent pipe sizes to termination.

A B
3-1/2 (89) - 2 in. kits 4-1/2 (114) - 3 in. kits

6-1/2 (165)

6 (152)
EXHAUST AIR

INTAKE AIR

Cat. No.
71M80 69M29 44W92 (Canada)
60L46
44W93 (Canada)

A in. mm
33-3/8 848

29

737

38-7/8 987

36-1/8 918

ELBOW (Field Supplied)

TERMINATION ASSEMBLY (Furnished)

Outdoor Exhaust Accelerator included with 71M80/44W92

B in. mm 16-3/4 425
15-1/2 394
21-3/16 538
19-1/2 495

NOTE - Typical illustration for dimensions only. Design may vary depending on kit ordered.

ML193DFE / Page 17

DIMENSIONS - OPTIONAL ACCESSORIES - VENTING

WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE
2 inch (51 mm) 22G44 (US) 3 inch (76 mm) 44J40 (US) See Installation Instructions for additional information.
Note - Field provided reducer may be required to adapt different vent pipe sizes to termination.

If Intake and Exhaust Pipe is less than12 in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed.

WALL SUPPORT

8 (203) MIN. Between Ends of Exhaust and Intake Pipe 12 (305) MAX. for 2 (51) Dia. Exhaust 20 (508) MAX. for 3 (76) Dia. Exhaust

6 (152) Maximum
INTAKE AIR

EXHAUST AIR

INTAKE AIR

5 (127)

8 (203) MIN.

12 (305) Minimum Above Grade or Average
Snow Accumulation
GRADE

12 (305) MAX. for 2 (51) Dia. Exhaust 20 (508) MAX. for 3 (76) Dia. Exhaust

12 (305)
5-1/2 (140)

1/2 (13) FOAM INSULATION
(Field Furnished)
EXHAUST AIR
12 (305) Minimum Above Grade or Average
Snow Accumulation
GRADE

WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE
2 inch (51 mm) 30G28 (WTK Canada) 3 inch (76 mm) 81J20 (WTK Canada) See Installation Instructions for additional information.
Note - Field provided reducer may be required to adapt different vent pipe sizes to termination.
If Intake and Exhaust Pipe is less than 12 in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed.

WALL SUPPORT
6 (152) Maximum
INTAKE AIR

12 (305) MAX. for 2 (51) Dia. Exhaust 20 (508) MAX. for 3 (76) Dia. Exhaust

6 (152) MIN.

EXHAUST AIR

INTAKE AIR

5 (127)

6 (152) MIN.

12 (305) Minimum Above Grade or Average
Snow Accumulation
GRADE

12 (305) MAX. for 2 (51) Dia. Exhaust 20 (508) MAX. for 3 (76) Dia. Exhaust

12 (305)
5-1/2 (140)

1/2 (13) FOAM INSULATION
(Field Furnished)
EXHAUST AIR
12 (305) Minimum Above Grade or Average
Snow Accumulation
GRADE

ML193DFE / Page 18

BLOWER DATA

ML193DF045XE36B PERFORMANCE (Less Filter)

External Static
Pressure in. w.g.

High (Black)

cfm

Watts

Air Volume / Watts at Various Blower Speeds

Medium-High (Brown)

Medium (Blue)

Medium-Low (Yellow)

cfm

Watts

cfm

Watts

cfm

Watts

0.00

1430

353

1305

270

1180

199

890

107

0.10

1395

364

1270

279

1145

207

845

113

0.20

1365

375

1245

291

1105

212

795

121

0.30

1330

383

1215

298

1070

221

740

126

0.40

1305

391

1180

310

1025

228

700

136

0.50

1275

400

1140

320

980

237

660

143

0.60

1245

406

1110

328

950

250

615

147

0.70

- - -

- - -

1080

335

910

252

585

151

0.80

- - -

- - -

1030

332

870

264

545

160

Low (Red)

cfm

Watts

740

70

695

76

640

81

575

86

530

93

485

97

445

103

390

107

335

116

ML193DF070XE36B PERFORMANCE (Less Filter)

External Static
Pressure in. w.g.

High (Black)

cfm

Watts

Air Volume / Watts at Various Blower Speeds

Medium-High (Brown)

Medium (Blue)

Medium-Low (Yellow)

cfm

Watts

cfm

Watts

cfm

Watts

0.00

1415

340

1295

269

1175

191

905

101

0.10

1380

351

1265

276

1140

202

860

109

0.20

1345

360

1240

285

1090

208

810

119

0.30

1325

371

1215

291

1060

218

770

124

0.40

1295

380

1175

302

1025

228

710

132

0.50

1260

392

1135

318

985

236

670

138

0.60

1235

402

1105

320

955

247

620

146

0.70

1185

411

1080

333

910

254

585

152

0.80

- - -

- - -

1040

342

865

261

540

157

Low (Red)

cfm

Watts

750

64

700

73

645

79

590

84

530

91

490

94

440

102

395

106

340

113

ML193DF090XE48C PERFORMANCE (Less Filter)

External Static
Pressure in. w.g.

High (Black)

cfm

Watts

Air Volume / Watts at Various Blower Speeds

Medium-High (Brown)

Medium (Blue)

Medium-Low (Yellow)

cfm

Watts

cfm

Watts

cfm

Watts

0.00

1720

412

1530

281

1400

220

1290

187

0.10

1695

418

1495

288

1365

229

1265

194

0.20

1680

431

1445

300

1315

240

1240

204

0.30

1640

444

1410

309

1285

247

1200

214

0.40

1605

455

1385

318

1245

255

1160

218

0.50

1575

466

1355

325

1215

263

1115

227

0.60

1550

473

1310

334

1165

274

1085

232

0.70

1490

467

1265

346

1125

282

1030

243

0.80

- - -

- - -

1240

354

1075

288

995

251

Low (Red)

cfm

Watts

1195

146

1160

152

1110

159

1070

165

1020

171

975

179

925

188

885

195

825

202

ML193DFE / Page 19

REVISIONS
Sections Optional Accessories

Description of Change Removed Wall Ring Kit (discontinued).

Visit us at www.lennox.com For the latest technical information, www.LennoxPros.com Contact us at 1-800-4-LENNOX

NOTE - Due to Lennox' ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.

Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.

Installation and service must be performed by a qualified installer and servicing agency.