HVAC USA - 042N0824
Contact Danfoss for delivery of coils for other voltages. Symbol. Description. Enclosure grade. Code no. Cable plug for 6.3 ∞ 0.8 mm. IP 65. 042N0139 spade ...
IP 00 with spade connector; IP 65 with cable plug. Ambient temperature. Max. 50°C. Duty rating. Continuous. • Compact. • Windings of class H insulated wire ...
Data sheet December 2001 Coils for solenoid valves DKACV.PD.600.A3.02 520B1131 Coils for industrial valves Contents Coil type A-series, 9 mm system AB AC AK AL AM AR (EEx mIIT4) B-series, 13.5 mm system BA BD BB BE BG BN (hum-free) BO (EEx mIIT4) BP (EEx mIIT4) Enclosure IP00, IP65 IP00, IP65 IP00 IP00 IP00 IP65 IP00, IP20, IP65 IP00, IP20, IP65 IP00, IP20, IP65 IP67 IP67 IP67 IP67 IP67 Power consumption ac dc 4.5 W 5 W 7 W 10 W 3 W 4 W 7.5 W 9.5 W 6 W 4.8/7 W 9 W 15W 10 W 10 W 12 W 20 W 10 W 15W 18 W 18 W 20 W 10 W 16 W Page 3 4 5 6 7 8 9 9 10 11 12 13 14 15 Compatibility X = typical choice · = optional choice for specific applications Solenoid valve type 2/2-way Compact EV210A EV220A EV220A with filter 2/2-way High Performance EV210B EV212B EV220B 6-12 EV220B 15-50 EV220B 65-100 EV222B EVI-U / EVSI-U EV250B 3/2-way Compact EV310A 3/2-way High Performance EV310B Valves for distinct purposes EV215B / EV225B / EV245B EVSIS (UL approved) EV260B 1) NC versions only 2) NO versions only Coil type AB AC AK AL AM AR X1) X1) X1) X X · X X X X · XX BA BD BB BE BG BN BO BP X XX X X · · · X XX X · · · · X XX X X · · · X XX X X · · · XX X X · · · X X · · · · See datasheet DKACV.PD.200.G X X X · · · AB AC AK AL AM AR X2) X X2) X X BA BD BB BE BG BN BO BP X X · · · · · · See specific datasheet See specific datasheet See specific datasheet 2 DKACV.PD.600.A3.02 Danfoss A/S 12-2001 Features Coils type AB 4.5 W ac 5 W dc IP 00 IP 65 · Compact · Windings of class H insulated wire moulded in the coil body · Ambient temperature: Up to +50°C · All usual ac and dc voltages · IP 00 version with 6.3 0.8 mm spade connectors · IP 65 version with mounted cable plug Technical data Ordering Design Voltage tolerance Power consumption. cut-in Power consumption. holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 ± 10% ac: 9.5 VA ac: 6.3 VA. 4.5 W / dc: 5 W Class H according to IEC 85 Spade connectors, 6.3 0.8 mm IP 00 with spade connector; IP 65 with cable plug Max. +50°C Continuous 4.5 W ac 5 W dc Coil type AB024C AB110C AB230C AB240C AB012D AB024D Supply voltage 24 V, 50/60 Hz 110 V, 50/60 Hz 220-230 V, 50/60 Hz 240 V, 50/60 Hz 12 V 24 V Contact Danfoss for delivery of coils for other voltages Symbol Description Cable plug for 6.3 0.8 mm spade connectors Enclosure grade IP 65 Code no. IP 00 042N0802 042N0804 042N0800 042N0801 042N0806 042N0803 Code no. 042N0139 Dimensions and weight Weight: 0.05 kg Without cable plug With cable plug L 40 mm 56 mm DKACV.PD.600.A3.02 Danfoss A/S 12-2001 3 IP 00 IP 65 Features Coils type AC 7.0 W ac 10 W dc · Compact · Windings of class H insulated wire moulded in the coil body · Ambient temperature: Up to +50°C · IP 00 version with 6.3 0.8 mm spade connectors · IP 65 version with mounted cable plug Technical data Ordering Design Voltage tolerance Power consumption. cut-in Power consumption. holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 ± 10% ac: 15.7 VA ac: 10 VA. 7 W / dc: 10 W Class H according to IEC 85 Spade connectors, 6.3 0.8 mm IP 00 with spade connector; IP 65 with cable plug Max. +50°C Continuous Coil Supply type voltage AC024C 24 V, 50/60 Hz 7 W ac AC110C AC230C 110 V, 50/60 Hz 220 - 230 V, 50/60 Hz AC240C 240 V, 50/60 Hz 10 W dc AC012D AC024D 12 V 24 V Contact Danfoss for delivery of coils for other voltages Symbol Description Cable plug for 6.3 0.8 mm spade connectors Enclosure grade IP 65 Code no. IP 00 042N0823 042N0825 042N0821 042N0822 042N0826 042N0824 Code no. 042N0139 Dimensions and weight Weight: 0.05 kg Without cable plug With cable plug L 40 mm 56 mm 4 DKACV.PD.600.A3.02 Danfoss A/S 12-2001 IP 00 Features Coils type AK 3.0 W dc · Compact · Windings of class H insulated wire moulded in the coil body · Ambient temperature: Up to +50°C · Power consumption: Only 3 W dc · IP 00 version with spade connector in accordance with DIN 43650, form A · IP 20 version with protective cap · IP 65 version with mounted cable plug Technical data Design Voltage tolerance Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 ± 10% dc: 3 W Class H according to IEC 85 Spade connector in accordance with DIN 43650 form A IP 00: Spade connector; IP 20: Protective cap; IP 65: Cable plug Max. +50°C Continuous Ordering 3 W dc Coil type AK024D Supply voltage 24 V Contact Danfoss for delivery of coils for other voltages Symbol Description Protective cap (pack of 100 pcs.) Cable plug according to DIN 43650-A Pg 11 Enclosure grade IP 20 IP 65 Code no. IP 00 042N0844 Code no. 018Z0282 042N0156 Dimensions and weight Weight: 0.10 kg Without cable plug With protective cap With cable plug L 48 mm 64 mm 72 mm DKACV.PD.600.A3.02 Danfoss A/S 12-2001 5 IP 00 Features Coils type AL 4.0 W ac · Compact · Windings of class H insulated wire moulded in the coil body · Ambient temperature: Up to +50°C · Power consumption: Only 4 W ac · IP 00 version with spade connector in accordance with DIN 43650, form A · IP 20 version with protective cap · IP 65 version with mounted cable plug Technical data Ordering Design Voltage tolerance Power consumption cut-in Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 ± 10% 10 VA ac: 4 W Class H according to IEC 85 Spade connector in accordance with DIN 43650 form A IP 00: Spade connector; IP 20: Protective cap; IP 65: Cable plug Max. +50°C Continuous 4 W ac Coil type AL230C Supply voltage 230 V ac, 50/60 Hz Contact Danfoss for delivery of coils for other voltages Symbol Description Protective cap (pack of 100 pcs.) Cable plug according to DIN 43650-A Pg 11 Enclosure grade IP 20 IP 65 Code no. IP 00 042N0864 Code no. 018Z0282 042N0156 Dimensions and weight Weight: 0.10 kg Without cable plug With protective cap With cable plug L 48 mm 64 mm 72 mm 6 DKACV.PD.600.A3.02 Danfoss A/S 12-2001 IP 00 Features Coils type AM 7.5 W ac 9.5 W dc · Compact · Windings of class H insulated wire moulded in the coil body · Ambient temperature: Up to +50°C · All usual ac and dc voltages · IP 00 version with spade connector in accordance with DIN 43650, form A · IP 20 version with protective cap · IP 65 version with mounted cable plug Technical data Ordering Design Voltage tolerance Power consumption, cut-in Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 ± 10% ac: 22.5 VA ac: 15 VA, 7.5 W / dc: 9.5 W Class H according to IEC 85 Spade connector in accordance with DIN 43650 form A IP 00: Spade connector; IP 20: Protective cap; IP 65: Cable plug Max. +50°C Continuous Coil Supply type voltage AM024C 24 V, 50/60 Hz 7.5 W ac AM110C AM230C 110 V, 50/60 Hz 220-230 V, 50/60 Hz AM240C 240 V, 50/60 Hz 9.5 W dc AM012D AM024D 12 V 24 V Contact Danfoss for delivery of coils for other voltages Symbol Description Protective cap (pack of 100 pcs.) Cable plug according to DIN 43650-A Pg 11 Enclosure grade IP 20 IP 65 Code no. IP 00 042N0842 042N0845 042N0840 042N0841 042N0848 042N0843 Code no. 018Z0282 042N0156 Dimensions and weight Weight: 0.10 kg Without cable plug With protective cap With cable plug L 48 mm 64 mm 72 mm DKACV.PD.600.A3.02 Danfoss A/S 12-2001 7 IP 65 Features Technical data Ordering Dimensions Coils type AR; EEx m II T4 6 W ac 4.8 W dc, 7 W dc · Compact · The coils are suitable for use in installations where flammable liquids and gases are produced, transported or tapped · Approvals for use in Zone 1 according to Directive 94/9/EC (ATEX 100A) EN50014 and EN50028 · Grade of enclosure IP 65 to IEC 529 · Supplied with 3, 3.8 or 5.5 m moulded-in 3-core cable Voltage tolerance Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Media temperature Duty rating ± 10% ac: 6 W, dc: 4.8 W and 7 W Class H according to IEC 85 3, 3.8 or 5.5 m 3-core cable IP 65 Max. +55° C Max. +90° C Continuous Conformity certification EX DEMKO 99ATEX 125689X Coil Type Supply Voltage 6 W ac 6 W ac 7 W dc 4.8 W dc AR024C AR230C AR024D AR024D 24 V, 50/60 Hz 230 V, 50/60 Hz 24 V dc 24 V dc Cable 5.5 m 5.5 m 5.5 m 5.5 m Code no. 042N5525 042N5535 042N5505 042N5515 Moulded-in 3 m, 3-core cable Weight approx. 0.3 kg Special requirements: The supply must be secured against a too high power consumption in case of a short circuit 8 DKACV.PD.600.A3.02 Danfoss A/S 12-2001 IP 00 Features Coil type BA and BD 9 W/15 W ac 15 W dc · Windings of class H insulated wire moulded in the coil body · Ambient temperature: Up to +40°C and +50C · All usual ac and dc voltages · IP 00 version with spade connector in accordance with DIN 43650, form A · IP 20 version with protective cap · IP 65 version with mounted cable plug Technical data Ordering Dimensions and weight Design Voltage tolerance Power consumption, cut-in Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 220/380 V ac coils: +10%, 15%. 230/400 V ac coils: +6%, 10%. Other ac coils with NC valve: +10%, 15% Other ac coils with NO valve and all dc coils: ±10% BA ac: 39 VA BD ac: 54 VA ac: 19 VA, 9 W / dc: 29 VA, 15 W Class H according to IEC 85 Spade connector in accordance with DIN 43650 form A IP 00 with spade connec. IP 20 with protective cap; IP 65 with cable plug Max . +40°C for BA / Max. +50°C for BD Continuous 9 W ac 15 W ac 15 W dc Coil Type BA024A BA048A BA115A BA230A BA240A BA380A BA024B BA115B BA220B BD024A BD110A BD230A BA012D BA024D Supply voltage 24 V, 50 Hz 48 V, 50 Hz 115 V, 50 Hz 220-230 V, 50 Hz 240 V, 50 Hz 380-400 V, 50 Hz 24 V, 60 Hz 115 V, 60 Hz 220 V, 60 Hz 24 V, 50 Hz 110 V, 50 Hz 230 V, 50 Hz 12 V 24 V Contact Danfoss for delivery of coils for other voltages Symbol Description Enclosure grade Protective cap (pack of 100 pcs.) IP 20 Cable plug according to DIN 43650-A Pg 11 IP 65 Code no. IP 00 042N7508 042N7510 042N7512 042N7501 042N7502 042N7504 042N7520 042N7522 042N7523 042N7597 042N7599 042N7541 042N7550 042N7551 Code no. 018Z0282 042N0156 DKACV.PD.600.A3.02 Weight: 0.16 kg Without cable plug With protective cap With cable plug L 54 mm 71 mm 79 mm Danfoss A/S 12-2001 9 IP 00, IP 20 IP 65 Features Coils type BB 10 W ac 18 W dc · Windings of class H insulated wire moulded in the coil body · Ambient temperature: Up to +80°C · All usual ac and dc voltages · IP 00 version with spade connector in accordance with DIN 43650, form A. · IP 20 version with protective cap · IP 65 version with mounted cable plug · Most common voltages as clip-on coil Technical data Design Voltage tolerance Power consumption, cut-in Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 220/380 V ac coils: +10%, 15%. 230/400 V ac coils: +6%, 10%. Other ac coils with NC valve: +10%, 15% Other ac coils with NO valve and all dc coils: ±10% ac: 44 VA ac: 21 VA, 10 W / dc: 18 W Class H according to IEC 85 Spade connector in accordance with DIN 43650 form A IP 00 with spade connec. IP 20 with protective cap; IP 65 with cable plug Max . +50/+80°C - see table below for details Continuous Ordering 10 W ac 18 W dc Coil Type BB024A BB115A BB230A BB240A BB380A BB024B BB110C BB230C BB012D BB024D Ambient Temperature max. +80°C max. +80°C max. +80°C max. +80°C max. +80°C max. +80°C max. +50°C max. +50°C max. +50°C max. +50°C Supply voltage 24 V, 50 Hz 115 V, 50 Hz 220-230 V, 50 Hz 240 V, 50 Hz 380-400 V, 50 Hz 24 V, 60 Hz 110 V, 50/60 Hz 220-230 V, 50/60 Hz 12 V 24 V Contact Danfoss for delivery of coils for other voltages Code no. IP 00 042N7408 042N7412 042N7401 042N7402 042N7404 042N7415 042N7430 042N7432 042N7456 042N7457 Clip-on 018F7358 018F7361 018F7351 018F7352 018F7360 018F7363 Symbol Description Protective cap (pack of 100 pcs.) Cable plug according to DIN 43650-A Pg 11 Enclosure grade IP 20 IP 65 Code no. 018Z0282 042N0156 Dimensions and weight Weight: 0.24 kg Without cable plug With protective cap With cable plug L 62 mm 77 mm 85 mm 10 DKACV.PD.600.A3.02 Danfoss A/S 12-2001 IP 67 Features Coils type BE 10 W ac 18 W dc · Clip-on version · Encapsulated coils with long operation life · Ambient temperature: Up to +80°C · Suitable for moist environments · All usual ac and dc voltages · IP 67 version with terminal box · IP 67 version 1 m 3-core flying lead · Can be fitted without tools · Can only be removed with tool Technical data Design Voltage tolerance Power consumption, cut-in Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 220/380 V ac coils: +10%, 15%. 230/400 V ac coils: +6%, 10%. Other ac coils with NC valve: +10%, 15% Other ac coils with NO valve and all dc coils: ±10% ac: 44 VA ac: 21 VA, 10 W / dc: 18 W Class H according to IEC 85 Terminal box; Pg 13.5 or 1 m 3-core flying lead IP 67 Max . +50/+80°C, see table below for details Continuous Ordering Dimensions and weight 10 W ac 18 W dc Coil Type BE024A BE048A BE115A BE240A BE240A BE380A BE024B BE115B BE220B BE110C BE230C BE012D BE024D Ambient temperature max. +80°C max. +80°C max. +80°C max. +80°C max. +80°C max. +80°C max. +80°C max. +80°C max. +80°C max. +50°C max. +50°C max. +50°C max. +50°C Supply voltage 24 V, 50 Hz 48 V, 50 Hz 115 V, 50 Hz 220-230 V, 50 Hz 240 V, 50 Hz 380-400, 50 Hz 24 V, 60 Hz 115 V, 60 Hz 220 V, 60 Hz 110 V, 50/60 Hz 220-230 V, 50/60 Hz 12 V 24 V Code no. With terminal box With cable 018F6707 018F6257 018F6709 018F6259 018F6711 018F6261 018F6701 018F6251 018F6702 018F6252 018F6703 018F6253 018F6715 018F6265 018F6710 018F6260 018F6714 018F6264 018F6730 018F6280 018F6732 018F6282 018F6756 018F6757 Contact Danfoss for delivery of coils for other voltages O-ring Terminal box with LED indication Application Coil enclosures 48-220 V dc 24-250 V, 50/60 Hz Code no. 018F0094 018Z0089 DKACV.PD.600.A3.02 Weight: 0.30 kg With terminal box With 1 m cable Danfoss A/S 12-2001 L 94 mm 65 mm 11 IP 67 Features Coils type BG 12 W ac 20 W dc · Clip-on version · Encapsulated coils with long operation life · Ambient temperature: Up to +80°C · All usual ac and dc voltages · Suitable for moist environments · IP 67 version with terminal box · Can be fitted without tools · Can only be removed with tool Technical data Ordering Design Voltage tolerance Power consumption, cut-in Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 220/380 V ac coils: +10%, 15%. 230/400 V ac coils: +6%, 10%. Other ac coils with NC valve: +10%, 15% Other ac coils with NO valve and all dc coils: ±10% ac: 44 VA ac: 21 VA, 10 W / dc: 18 W Class H according to IEC 85 Terminal box; Pg 13.5 IP 67 Max . +80°C Continuous 12 W ac 20 W dc Coil Type BG024A BG110A BG230A BG240A BG380A BG024B BG110B BG220B BG012D BG024D Contact Danfoss for delivery of coils for other voltages Supply voltage 24 V, 50 Hz 110 V, 50 Hz 220-230 V, 50 Hz 240 V, 50 Hz 380-400 V, 50 Hz 24 V, 60 Hz 110 V, 60 Hz 220 V, 60 Hz 12 V 24 V Description Application Code no. O-ring Coil enclosure 018F0094 Code no. IP 67 018F6807 018F6811 018F6801 018F6802 018F6803 018F6815 018F6813 018F6814 018F6856 018F6857 Dimensions and weight Weight: 0.50 kg With terminal box L 112 mm 12 DKACV.PD.600.A3.02 Danfoss A/S 12-2001 IP 67 Features Coils type BN 20 W ac Hum-free coil · Clip-on version · Windings of class H insulated wire moulded in the coil body · For installations sensitive to noise, such as heating systems · Ambient temperature: Up to +50°C · Built-in rectifier · Suitable for moist environments · Available with 1 m 3-core flying lead · Coil enclosure: IP 67 Technical data Design Voltage tolerance Power consumption, cut-in Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating In accordance with VDE 0580 ±10% ac: 24 VA ac: 26 VA Class H according to IEC 85 1 m 3-core flying lead; Pg 13.5 IP 67 Max . +50°C Continuous Ordering 20 W ac O-rings Coil type BN230C Supply voltage 220-230 V, 50/60 Hz Coil enclosure Dimensions and weight Code no. IP 67 018F7301 018F0094 Weight: 0.60 kg With 1 m cable L 112 mm DKACV.PD.600.A3.02 Danfoss A/S 12-2001 13 IP 67 Features Coils type BO; Eex m II T4 10 W ac 10 W dc · For explosion-risk environments, such as where flammable liquids and gases are produced, transported or tapped · Approvals for use in Zone 1 according to Directive 94/9/EC (ATEX 100A) EN50014 and EN50028 · Medium temperature: Up to +90°C · Ambient temperature: Up to +40°C · IP 67 version with 5 m 3-core flying lead · Seal kit as accessory for extremely wet and aggressive environments (please contact Danfoss) Technical data Ordering Voltage tolerance Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating Media temperature ±10% ac: 10 W / dc: 10 W Class H according to IEC 85 5 m 3-core flying lead IP 67 Max . +40°C Continuous Max . +90°C 10 W ac 10 W dc Coil Type BO024C BO048C BO110C BO230C BO240C BO024D Supply voltage 24 V, 50/60 Hz 48 V, 50/60 Hz 110 V, 50/60 Hz 220 - 230 V, 50/60 Hz 240 V, 50/60 Hz 24 V Code no. Standard SEV-approval 018Z6595 018Z6585 018Z6594 018Z6584 018Z6593 018Z6583 018Z6592 018Z6582 018Z6591 018Z6581 018Z6596 018Z6586 Description Seal kit Application Wet environment Code no. 018Z0090 Dimensions and weight Weight: 0.60 kg 14 DKACV.PD.600.A3.02 Danfoss A/S 12-2001 IP 67 Features Coils type BP; EEx m II T4 16 W dc · The coils are suitable for use in installations where flammable liquids and gases are produced, transported or tapped · Approved for use in Zone 1 according to Directive 94/9/EC (ATEX 100A) EN50014 and EN50028 · Grade of enclosure IP 67 · Supplied with 3 m moulded-in 3-core cable Technical data Ordering Dimensions Voltage tolerance Power consumption, holding Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Media temperature Duty rating ± 10% dc: 16 W Class H according to IEC 85 3 m 3-core cable IP 67 Max. +55° C Max. +90° C Continuous Conformity certification EX DEMKO 99ATEX 125688X 16 W dc Coil Type BP024D Supply Voltage 24 V dc Connection 3 m Code no. 018Z6633 Description Seal kit Application Wet environment Code no. 018Z0090 Moulded-in 3 m, 3-core cable Weight approx. 0.33 kg Special requirements: The supply must be secured against a too high power consumption in case of a short circuit DKACV.PD.600.A3.02 Danfoss A/S 12-2001 15 Coils for solenoid valves 16 DKACV.PD.600.A3.02 Danfoss A/S 12-2001 Produced by G1 advertising agency 01.12.MR.JN.PSAcrobat Distiller 4.05 for Windows