Measurement Report

Kent

Test Report

DOKE COMMUNICATION (HK) LIMITED BV4800PRO 2A7DX-BV4800PRO 2A7DXBV4800PRO bv4800pro

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7785852
Report No.: S24082201502008
FCC Test Report FCC ID: 2A7DX-BV4800PRO
Product: Mobile Phone Trade Mark: Blackview Model Number: BV4800 Pro Family Model: N/A Report No.: S24082201502008
Prepared for
DOKE COMMUNICATION (HK) LIMITED 19H MAXGRAND PLAZA NO 3 TAI YAU STREET SAN PO KONG KL
Prepared by
Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community,
Xixiang Street Bao'an District, Shenzhen P.R. China Tel. 400-800-6106, 0755-2320 0050, 0755-2320 0090
Website:http://www.ntek.org.cn

Version.1.2

Page 1 of 19

Report No.: S24082201502008

TEST RESULT CERTIFICATION

Applicant's name.................. : DOKE COMMUNICATION (HK) LIMITED

19H MAXGRAND PLAZA NO 3 TAI YAU STREET SAN PO Address .................................. :
KONG KL

Manufacturer's Name........... : Shenzhen DOKE Electronic Co., Ltd

Address .................................. :

801, Building3, 7th Industrial Zone, Yulv Community, Yutang Road, Guangming District, Shenzhen, China.

Product description

Product name ......................... : Mobile Phone

Model and/or type reference : BV4800 Pro

Family Model .......................... : N/A

FCC Part15B Standards.............................. : ANSI C63.4:2014

This device described above has been tested by NTEK, and the test results show that the equipment under test (EUT) is in compliance with Part 15 of FCC Rules. And it is applicable only to the tested sample identified in the report.

This report shall not be reproduced except in full, without the written approval of NTEK, this

document may be altered or revised by NTEK, personnel only, and shall be noted in the revision

of the document.

Test Sample Number................:

S240822015001

Date of Test ........................................... :

Date (s) of performance of tests............. : Aug. 22, 2024 ~ Sept. 18, 2024

Date of Issue .......................................... : Sept. 18, 2024

Test Result .............................................. : Pass

Prepare d By

:

Joe Yan

(Project Engineer)

Reviewe d By

:

Aaron Cheng (Supervisor)

Approve d By

:

Alex Li

(Manager)

Version.1.2

Page 2 of 19

Report No.: S24082201502008

Table of Contents
1 . TEST SUMMARY
1.1 TEST FACILITY 1.2 MEASUREMENT UNCERTAINTY
2 . GENERAL INFORMATION
2.1 GENERAL DESCRIPTION OF EUT 2.2 DESCRIPTION OF TEST SETUP 2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL 2.4 MEASUREMENT INSTRUMENTS LIST
3 . EMC EMISSION TEST
3.1 CONDUCTED EMISSION MEASUREMENT 3.1.1 POWER LINE CONDUCTED EMISSION 3.1.2 TEST PROCEDURE 3.1.3 TEST SETUP 3.1.4 EUT OPERATING CONDITIONS 3.1.5 TEST RESULTS
3.2 RADIATED EMISSION MEASUREMENT 3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 3.2.2 TEST PROCEDURE 3.2.3 TEST SETUP 3.2.4 TEST RESULTS 3.2.5 TEST RESULTS(1000~18000MHz)

Page
4
5 5
6
6 8 9 10
11
11 11 12 12 12 13 15 15 15 16 17 19

Version.1.2

Page 3 of 19

Report No.: S24082201502008

1. TEST SUMMARY

Test procedures according to the technical standards: EMC Emission

Standard

Test Item

Limit

Judgment Remark

FCC Part15B ANSI C63.4: 2014

Conducted Emission Radiated Emission

Class B Class B

PASS PASS

NOTE: (1) 'N/A' denotes test is not applicable in this Test Report (2) For client's request and manual description, the test will not be executed.

Version.1.2

Page 4 of 19

Report No.: S24082201502008

1.1 TEST FACILITY

Shenzhen NTEK Testing Technology Co., Ltd Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao'an District, Shenzhen 518126 P.R. China.

IC-Registration

The Certificate Registration Number is 9270A.

CAB identifier:CN0074

FCC- Accredited

Test Firm Registration Number: 463705.

Designation Number: CN1184

1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of

approximately 95 %.

A. Conducted Measurement :

Test Site Method NTEKC01 ANSI

Measurement Frequency Range 150 KHz ~ 30MHz

U,(dB) ±2.80dB

NOTE

B. Radiated Measurement :

Test Site Method NTEKA01 ANSI

Measurement Frequency Range 30MHz~1000MHz 1GHz~6GHz 6GHz~26.5GHz

U,(dB) ±2.64dB ±2.40dB ±2.52dB

NOTE

Version.1.2

Page 5 of 19

2. GENERAL INFORMATION
2.1 GENERAL DESCRIPTION OF EUT

Report No.: S24082201502008

Equipment Trade Mark Model Name Family Model Model Difference

Mobile Phone Blackview BV4800 Pro N/A N/A

Connecting I/O port: Type-C USB

Product Description Adapter

Operation Frequency: 5.825GHz
Based on the application, features, or specification exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical specification, please refer to the User's Manual.
Model: HJ-0502000-US Input: 100-240V~50/60Hz 0.3A Output: 5.0V 2.0A 10.0W

Battery

DC 3.85V, 5180mAh, 19.94Wh

Power supply

DC 3.85V from battery or DC 5V from adapter

HW Version

Z665_MBA2_BOM2

SW Version

BV4800Pro_NEU_Z665_V1.0

Version.1.2

Page 6 of 19

Report No.: S24082201502008
2.1.1 DESCRIPTION OF TEST MODES
To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

Pretest Mode
Model 1 Model 2 Model 3 Model 4

Description
Data Transmission TF card Playing REC FM

Final Test Mode Model 1 Model 2 Model 3 Model 4

For Conducted Test
Description Data Transmission
TF card Playing REC FM

For Radiated Test

Final Test Mode

Description

Model 1 Model 2 Model 3 Model 4

Data Transmission TF card Playing REC FM

Note: Final Test Mode: Through Pre-scan, find the model 1 is the worst case.

Only the worst case mode is recorded in the report.

Version.1.2

Page 7 of 19

2.2 DESCRIPTION OF TEST SETUP CE
C-5

AE-6 Printer

AE-5 Monitor

C-4

0.8m

AC Plug AC Plug

AE-1 EUT

Report No.: S24082201502008

AE-2
PC C-1
AC PLUG

C-3 C-2

AE-3 KB

AE-4 Mouse

RE AC Plug

1.5m C-4

AE-6 Printer
0.8m

AE-2

C-1

PC

C-5

C-2

C-3

AE-3 KB

AE-4 Mouse

AC PLUG

AC PLUG

AE-1 EUT

AE-5 Monitor

1.5m

Version.1.2

Page 8 of 19

Report No.: S24082201502008

2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL
The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests.

Item AE-1 AE-2 AE-3 AE-4 AE-5 AE-6 AE-7

Equipment
Mobile Phone PC KB
Mouse Monitor Printer Earphone

Brand Blackview
DELL N/A
N/A N/A Canon N/A

Model/Type No. BV4800 Pro
FT4Y23X N/A N/A
N/A L11121E
N/A

Series No. N/A N/A N/A N/A N/A N/A N/A

Note EUT Peripherals Peripherals Peripherals Peripherals Peripherals Peripherals

Item Cable Type Shielded Type

C-1 USB Cable

NO

C-2 USB Cable

NO

C-3 USB Cable

NO

C-4 HDMI Cable

YES

C-5 USB Cable

NO

C-6 Earphone Cable

NO

Ferrite Core NO NO NO YES NO NO

Length 1.0m 1.2m 1.2m 1.0m 1.2m 1.5m

Note

Note:
(1) The support equipment was authorized by Declaration of Confirmation. (2) For detachable type I/O cable should be specified the length in cm inLengthcolumn. (3) "YES" means "shielded" "with core"; "NO" means "unshielded" "without core".

Version.1.2

Page 9 of 19

Report No.: S24082201502008

2.4 MEASUREMENT INSTRUMENTS LIST

Radiation Test equipment

Item Kind of Equipment
1 Spectrum Analyzer

Manufacturer Agilent

2 Test Receiver

R&S

Type No. E4440A

Serial No.

Last

calibration

MY41000130 2024.04.26

ESPI

101318 2024.04.26

3 Bilog Antenna TESEQ

CBL6111D

31216

2024.05.12

4

50 Coaxial Switch

Anritsu

MP59B 6200264416 2024.03.12

5

Spectrum Analyzer

ADVANTEST

R3132

150900201 2024.03.12

6 Horn Antenna

EM

EM-AH-1018 0

2011071402

2024.05.12

7

Horn Ant Schwarzbeck BBHA 9170 9170-181 2024.05.12

8

Amplifier

9 Loop Antenna

10 Power Meter

11 Power Sensor

12

Test Cable (30MHz-1GHz)

High Test

13 Cable(1G-40G

Hz)

High Test

14 Cable(1G-40G

Hz)

15 Test Receiver

EMC ARA DARE R&S N/A N/A
N/A R&S

EMC051835 SE

980246

PLA-1030/B 1029

RPR3006W URV4-Z4

15I00041SN O84
0395.1619.0 5

2024.04.25 2024.04.25 2024.04.25 2024.04.25

R-02

N/A

2023.05.06

R-03

N/A

2022.06.17

R-04 ESCI

N/A 101160

2023.05.06 2024.04.26

Calibrated Calibration

until

period

2025.04.25 1 year

2025.04.25 2025.05.11

1 year 1 year

2025.03.11 1 year

2025.03.11 1 year

2027.05.11 3 year

2027.05.11 3 year

2025.04.24 2025.04.24 2025.04.24

1 year 1 year 1 year

2025.04.24 1 year

2026.05.05 3 year

2025.06.16 3 year

2026.05.05 3 year 2025.04.25 1 year

AC Conduction Test equipment

Item

Kind of Equipment

Manufacturer

Type No.

Serial No.

Last calibration

Calibrated Calibration

until

period

1 Test Receiver

R&S

ESCI

101160 2024.04.26 2025.04.25 1 year

2

LISN

R&S

ENV216

101313 2024.04.25 2025.04.24 1 year

3

LISN

SCHWARZBE CK

NNLK 8129

8129245

2024.04.25 2025.04.24

1 year

4

50 Coaxial Switch

ANRITSU CORP

MP59B 6200983704 2024.04.26 2027.04.25 3 year

Test Cable

5 (9KHz-30MH

N/A

C01

N/A

2023.05.06 2026.05.05 3 year

z)

Test Cable

6 (9KHz-30MH

N/A

C02

N/A

2023.05.06 2026.05.05 3 year

z)

Test Cable

7 (9KHz-30MH

N/A

C03

N/A

2023.05.06 2026.05.05 3 year

z)

Note: Each piece of equipment is scheduled for calibration once a year except the Test Cable which is

scheduled for calibration every 3 years.

Version.1.2

Page 10 of 19

Report No.: S24082201502008
3. EMC EMISSION TEST
3.1 CONDUCTED EMISSION MEASUREMENT 3.1.1 POWER LINE CONDUCTED EMISSION (Frequency Range 150KHz-30MHz)

FREQUENCY (MHz)

Class A (dBuV) Quasi-peak Average

Class B (dBuV)

Quasi-peak

Average

0.15 -0.5

79.00

66.00

66 - 56 *

56 - 46 *

0.50 -5.0

73.00

60.00

56.00

46.00

5.0 -30.0

73.00

60.00

60.00

50.00

Note:

(1) The tighter limit applies at the band edges.

(2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range.

The following table is the setting of the receiver Receiver Parameters Attenuation Start Frequency Stop Frequency IF Bandwidth

Setting 10 dB 0.15 MHz 30 MHz 9 kHz

Version.1.2

Page 11 of 19

Report No.: S24082201502008
3.1.2 TEST PROCEDURE a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item ­EUT Test Photos.
3.1.3 TEST SETUP

3.1.4 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special operating condition is specified in the follows during the testing.

Version.1.2

Page 12 of 19

Report No.: S24082201502008

3.1.5 TEST RESULTS

EUT: Temperature: Pressure: Test Mode: Test Voltage:

Mobile Phone

Model Name. : BV4800 Pro

24.5 

Relative Humidity: 52%

1010hPa

Test Date:

2024-08-27

Mode 1

Phase :

L

DC 5V from PC AC 120V/60Hz

Frequency Reading Level Correct Factor Measure-ment

(MHz)

(dBV)

(dB)

(dBV)

0.1693

48.89

9.97

58.86

0.1693

34.22

9.97

44.19

0.2378

38.96

10.12

49.08

0.2378

22.36

10.12

32.48

0.3131

28.81

10.26

39.07

0.3131

14.17

10.26

24.43

0.7960

28.27

11.26

39.53

0.7960

27.11

11.26

38.37

1.5933

23.58

12.84

36.42

1.5933

15.32

12.84

28.16

6.2850

33.33

9.68

43.01

6.2850

20.44

9.68

30.12

Remark:
1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss.

Limits (dBV)
64.99 54.99 62.17 52.17 59.89 49.89 56.00 46.00 56.00 46.00 60.00 50.00

Margin (dB) -6.13 -10.80 -13.09 -19.69 -20.82 -25.46 -16.47 -7.63 -19.58 -17.84 -16.99 -19.88

Remark
peak AVG peak AVG peak AVG peak AVG peak AVG peak AVG

Version.1.2

Page 13 of 19

Report No.: S24082201502008

EUT: Temperature: Pressure: Test Mode: Test Voltage:

Mobile Phone

Model Name. : BV4800 Pro

24.5 

Relative Humidity: 52%

1010hPa

Test Date:

2024-08-27

Mode 1

Phase :

N

DC 5V from PC AC 120V/60Hz

Frequency Reading Level Correct Factor Measure-ment

(MHz)

(dBV)

(dB)

(dBV)

0.1615

51.12

9.95

61.07

0.1615

38.64

9.95

48.59

0.2416

39.08

10.12

49.20

0.2416

23.46

10.12

33.58

0.3482

29.49

10.34

39.83

0.3482

14.09

10.34

24.43

0.4040

24.54

10.45

34.99

0.4040

6.52

10.45

16.97

0.7960

27.55

11.26

38.81

0.7960

26.51

11.26

37.77

1.5933

27.49

12.84

40.33

1.5933

20.07

12.84

32.91

Remark:
1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss.

Limits (dBV)
65.39 55.39 62.04 52.04 59.01 49.01 57.77 47.77 56.00 46.00 56.00 46.00

Margin (dB) -4.32 -6.80 -12.84 -18.46 -19.18 -24.58 -22.78 -30.80 -17.19 -8.23 -15.67 -13.09

Remark
peak AVG peak AVG peak AVG peak AVG peak AVG peak AVG

Version.1.2

Page 14 of 19

Report No.: S24082201502008

3.2 RADIATED EMISSION MEASUREMENT 3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT

FREQUENCY (MHz)
30 ~ 88 88 ~ 216 216 ~ 960 Above 960

Class A (at 10m) dBuV/m 39.0 43.5 46.5 49.5

Class B (at 3m) dBuV/m 40.0 43.5 46.0 54.0

Notes:
(1) The limit for radiated test was performed according to as following: FCC PART 15B /ICES-003.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m)=20log Emission level (uV/m).

3.2.2 TEST PROCEDURE

Test Arrangement for Radiated Emissions up to 1 GHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited test facility. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower.
c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.

Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for quasi-peak detection (QP) at frequency below 1GHz.
Test Arrangement for Radiated Emissions above 1 GHz.

a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited chamber room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. c. The height of antenna can be varied from one meter to four meters, the height of adjustment
depends on the EUT height and the antenna 3dB beamwidth both, to detect the maximum value of the field strength.Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading. NoteFor the hand-held device, the EUT should be measured for all 3 axes and only the
worst case is recorded in the report

Version.1.2

Page 15 of 19

Report No.: S24082201502008
During the radiated emission test, according to ANSI C63.4-2014(4.2), the Spectrum Analyzer was set with the following configurations:

Frequency Band (MHz)
30 to 1000
Above 1000

Function
QP Peak Avg

Resolution bandwidth
120 kHz 1 MHz 1 MHz

Video Bandwidth
300 kHz 3 MHz 10 Hz

3.2.3 TEST SETUP For Radiated Emission 30~1000MHz

Turntable EUT
Test Receiver
Ground Plane

3m 0.8m

1m to 4m Coaxial Cable

(B) Radiated Emission Test Set-Up Frequency Above 1GHz

Version.1.2

Page 16 of 19

Report No.: S24082201502008

3.2.4 TEST RESULTS

TEST RESULTS (30~1000 MHz)

EUT:

Mobile Phone

Temperature: 24.5 

Pressure:

1010 hPa

Test Mode : Mode 2

Test Power : DC 5V from PC AC 120V/60Hz

Model Name: Relative Humidity: Test Date : Polarization :

BV4800 Pro 55% 2024-08-24 Horizontal

Polar (H/V)

Frequency (MHz)

Meter Reading
(dBuV)

Factor (dB)

Emission Level
(dBuV/m)

H

2564.000

H

2564.000

H

4553.000

H

4553.000

H

5760.000

H

5760.000

H

12254.000

H

12254.000

H

15212.000

H

15212.000

H

16589.000

H

16589.000

45.91 28.17 45.11 29.28 46.10 30.16 46.65 29.49 43.74 27.65 45.02 26.47

-4.74 -4.74 0.49 0.49 3.14 3.14 11.67 11.67 14.01 14.01 13.81 13.81

41.17 23.43 45.60 29.77 49.24 33.30 58.32 41.16 57.75 41.66 58.83 40.28

Remark: Factor = Antenna Factor + Cable Loss - Amplifier.

Limits
(dBuV/m)
74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00

Margin
(dB)
-32.83 -30.57 -28.40 -24.23 -24.76 -40.70 -15.68 -12.84 -16.25 -12.34 -15.17 -13.72

Remark
peak AVG peak AVG peak AVG peak AVG peak AVG peak AVG

Version.1.2

Page 17 of 19

Report No.: S24082201502008

EUT: Temperature: Pressure: Test Mode : Test Power :

Mobile Phone 24.5  1010 hPa Mode 2 DC 5V from PC AC 120V/60Hz

Model Name : Relative Humidity: Test Date : Polarization :

BV4800 Pro 55% 2024-08-24 Vertical

Polar (H/V)

Frequency (MHz)

Meter Reading
(dBuV)

Factor (dB)

Emission Level
(dBuV/m)

V

1561.000

50.01

-7.56

42.45

V

1561.000

35.16

-7.56

27.60

V

3142.000

46.58

-2.45

44.13

V

3142.000

32.26

-2.45

29.81

V

5114.000

45.06

2.20

47.26

V

5114.000

31.26

2.20

33.45

V

8565.000

47.35

8.38

55.73

V

8565.000

33.89

8.38

42.27

V

10894.000

46.08

12.19

58.27

V

10894.000

29.41

12.19

41.60

V

15688.000

44.27

13.59

57.86

V

15688.000

28.71

13.59

42.30

Remark: Factor = Antenna Factor + Cable Loss - Amplifier.

Limits
(dBuV/m)
74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00 74.00 54.00

Margin
(dB)
-31.55 -26.40 -29.87 -24.19 -26.74 -20.55 -18.27 -11.73 -15.73 -12.40 -16.14 -11.70

Remark
peak AVG peak AVG peak AVG peak AVG peak AVG peak AVG

Version.1.2

Page 18 of 19

Report No.: S24082201502008

3.2.5 TEST RESULTS(1000~18000MHz)

EUT:

Mobile Phone

Model Name :

BV4800 Pro

Temperature: 24.5 

Relative Humidity: 55%

Pressure:

1010 hPa

Test Date :

2024-08-23

Test Mode : Mode 1

Test Power : DC 5V from PC AC 120V/60Hz

All the modulation modes have been tested, and the worst result was report as below:

Polar (H/V)
V V V V V V H H H H H H

Frequency
(MHz)
66.0340 171.3925 238.3101 312.1792 480.5276 706.6997 66.2660 210.0481 251.1802 300.3672 360.4476 480.5276

Reading
(dBuV/m)
17.12 20.02 14.44 11.64 14.99 7.26 17.09 17.86 18.20 19.41 16.46 14.82

Correct
dB/m
17.23 15.43 18.08 20.46 23.84 27.90 17.13 17.78 18.56 20.21 21.79 23.84

Result
(dBuV/m)
34.35 35.45 32.52 32.10 38.83 35.16 34.22 35.64 36.76 39.62 38.25 38.66

Limit
(dBuV/m)
40.00 43.50 46.00 46.00 46.00 46.00 40.00 43.50 46.00 46.00 46.00 46.00

Over Limit
(dB)
-5.65 -8.05 -13.48 -13.90 -7.17 -10.84 -5.78 -7.86 -9.24 -6.38 -7.75 -7.34

Remark
peak peak peak peak peak peak peak peak peak peak peak peak

Remark: Result = Reading + Correct, Over Limit= Result - Limit Note: Only the worst results data points are reported in the report. Other emissions are attenuated 20dB below the limit that does not recorded in the report.

END OF REPORT

Version.1.2

Page 19 of 19


Microsoft Office Word 2007 Microsoft Office Word 2007