Single Pack GS26MFX 220-240V 50Hz CSCR
Product Overview
This document provides technical data for the Secop GS26MFX compressor, supplied as a single pack.
Single pack code number: 195B4633
Components in Single Pack
Position | Title | Code | Amount |
---|---|---|---|
1 | Compressor GS26MFX | 107B0700 | 1 |
2 | GS starting device (600mm) | 117-7055 | 1 |
3 | Bolt joint for one compressor | M8 | ø19mm | 107B9150 | 1 |
Technical Data - Compressor
Compressor Design
Oil type | Polyolester |
Oil viscosity | 32,5cST |
Oil quantity | 902cm³ / 30,5fl.oz |
Refr. charge - tech. limit | 2000g / 70,5oz |
Free gas volume comp. | 3350cm³ / 113,3fl.oz |
Weight | 19,1kg / 42,1lbs |
Motor protection | 1# internal [internal symbol] |
Winding resistance main | 3,7Ω (at 25°C) |
Winding resistance aux | 4Ω (at 25°C) |
Max. winding temp. | 135°C / 275°F |
Max. discharge temp. | 130°C / 266°F |
Refrigerant(s) | R134a, R513A |
Displacement | 26,3cm³ / 1,6cu.in |
Compressors on pallet | 48 |
Illustration of a Secop G-Series compressor.
Configurations
General Configurations with GS26MFX
Conf. 1 | Conf. 2 | |
---|---|---|
Motorconfiguration | CSCR | CSCR |
Power supply (nominal) | 220-240V/50Hz | 220-240V/50Hz |
Number of phases | 1 | 1 |
Voltage range | 198-254V | 198-254V |
Approvals | VDE, CCC | VDE, CCC |
Starting torque | HST | HST |
Note | Cover, clamp, gasket: pre-assembled to compressor | Cover, clamp, gasket: pre-assembled to compressor |
Applications with GS26MFX
Conf. 1 | Conf. 2 | |
---|---|---|
Refrigerant | R134a | R513A |
Application | MBP | MBP |
System cooling | fan 3m/s | fan 3m/s |
Hot gas defrost | OK | OK |
Long interval pull down | OK | OK |
Electrical Data - Configurations with GS26MFX
Conf. 1 | Conf. 2 | |
---|---|---|
Starting device type | relay | relay |
Run capacitor | 20μF | 20μF |
Start capacitor | 100μF | 100μF |
LRA (locked rotor amps / 4s) | 20A | 20A |
RLA (rated load amps / 1s) | 3,8A | 3,8A |
Cut in current | 20A | 20A |
IP class | 21 | 21 |
Dimensions
Housing Dimensions
A Height | 259mm / 10,2in |
B Height | 247mm / 9,72in |
C Length shell | 224mm / 8,82in |
D Length w. cover | 232mm / 9,13in |
E Width | 173mm / 6,81in |
Connectors
Suction (X) | Discharge (Y) | Process (Z) | |
---|---|---|---|
Diameter [mm] | øi 12,75-13,05 | øi 8,15-8,25 | øi 6,4-6,6 |
Diameter [in] (i:inside, o:outside) | øi 0,5-0,51 | øi 0,32-0,32 | øi 0,25-0,26 |
Material | copper | copper | copper |
Horizontal angle | ±2° | 0° | 0° |
Vertical angle | ±2° | 90° | 71° |
Position l/h/w [mm] | -95/234/-84 | -105/84/-84 | 95/234/84 |
Position l/h/w [in] | -3,7/9,2/-3,3 | -4,1/3,3/-3,3 | 3,7/9,2/3,3 |
Straight tube l. [mm] | 18 | 23 | 15 |
Straight tube l. [in] | 0,7 | 0,9 | 0,6 |
Diagram showing compressor dimensions and connector details with angles and positions.
Compressor Fixation
Component | [mm] | [inch] |
---|---|---|
Baseplate BI | 235 | 9.25 |
Baseplate Bw | 154 | 6.06 |
øE | Ø 3.6 | Ø 0.14 |
Large holes LI | 203 | 7.99 |
Large holes Lw | 122 | 4.80 |
øL | Ø 19 | Ø 0.75 |
Diagram illustrating compressor fixation points and bolt joint dimensions. Includes details for baseplate, large holes, and bolt diameter.
Mounting accessories
Bolt joint | M8 | ø19mm
one comp. 107B9150
Performance and Operating Data
Configuration 1: General and Operating Conditions
Configuration Details
- Motorconfiguration: CSCR
- Power supply (nominal): 220-240V/50Hz 1~
- Refrigerant: R134a
- Application: MBP
- Voltage range: 198-254V
- Starting torque: HST
- Approvals: VDE, CCC
Ambient Temperatures / System Cooling
Ambient temperature min.: 10°C / 50°F
Ambient temperature max.: 43°C / 110°F
T ambient | LBP | MBP | HBP |
---|---|---|---|
32°C / 90°F | n/a | fan 3m/s | n/a |
38°C / 100°F | n/a | fan 3m/s | n/a |
43°C / 110°F | n/a | fan 3m/s | n/a |
Operation Pressure Range
Graph showing the relationship between condensing pressure (y-axis) and evaporation pressure (x-axis) for continuous and transitory operation, with temperature scales in Celsius and Fahrenheit.
Evaporation Pressure
Graph showing evaporation pressure (x-axis) versus condensing pressure (y-axis) for continuous and transitory operation.
Electrical Accessories / Wiring Diagram
Wiring diagram for the compressor, showing connections for motor windings (S, R, C), starter, capacitor, thermostat, and fan. Includes terminal designations and a key for wire colors (English column shown).
Component | Code |
---|---|
a3 GS starter kit (600mm) | 117-7055 |
b cover | 107B9101 |
b2 gasket | 107B9100 |
b1 clamp | 107B9104 |
Configuration 1: Optimization and Standard Conditions
RGT | Tliq | Cooling capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | Ref. mass flow m [kg/h] | Standard | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pe [°C] | pc [°C] | ||||||||||||
-6,66 | 54,4 | 35 | 46,1 | 1448,4 | 4947 | 1246,5 | 1,82 | 6,23 | 1,57 | 794,3 | 3,69 | 31,60 | ASHRAE MBP |
[°F] | [°F] | 95 | 115 | ||||||||||
-10 | 55 | 32 | 55 | 1118,3 | 3819 | 962,5 | 1,52 | 5,20 | 1,31 | 735,1 | 3,42 | 27,04 | cecomaf MBP |
[°F] | [°F] | 89,6 | 131 | ||||||||||
-10 | 45 | 20 | 45 | 1265,5 | 4322 | 1089,1 | 1,82 | 6,22 | 1,57 | 695,3 | 3,18 | 29,62 | EN12900 MBP |
[°F] | [°F] | 68 | 113 | ||||||||||
-6,66 | 48,9 | 18,3 | 48,9 | 1380,0 | 4713 | 1187,6 | 1,80 | 6,15 | 1,55 | 765,8 | 3,53 | 34,09 | ARI540 MBP |
[°F] | [°F] | 120 | 65 | 120 | |||||||||
-10 | 45 | 32 | 45 | 1314,1 | 4488 | 1131,0 | 1,89 | 6,45 | 1,63 | 695,3 | 3,18 | 28,76 | opt |
[°F] | [°F] | 113 | 89,6 | 113 | |||||||||
-25 | 45 | 32 | 45 | 575,5 | 1965 | 495,2 | 1,21 | 4,14 | 1,04 | 474,4 | 2,32 | 12,47 | opt |
[°F] | [°F] | 113 | 89,6 | 113 |
Configuration 1: Performance Tables
Cooling capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | m [kg/h] | ||
---|---|---|---|---|---|---|---|---|---|---|
[°C / °F] | ||||||||||
cond. pressure pc= 45/113 | -20 / -4 | 782,1 | 2671 | 673,1 | 1,43 | 4,89 | 1,23 | 545,7 | 2,57 | 16,99 |
-15 / 5 | 1026,0 | 3504 | 883,0 | 1,66 | 5,66 | 1,43 | 619,3 | 2,86 | 22,37 | |
return gas temp. RGT= 32/90 | -10 / 14 | 1314,1 | 4488 | 1131,0 | 1,89 | 6,45 | 1,63 | 695,3 | 3,18 | 28,76 |
-6,7 / 20 | 1531,9 | 5232 | 1318,3 | 2,05 | 7,00 | 1,76 | 747,0 | 3,42 | 33,63 | |
liquid temp Tliq= 45/113 | -5 / 23 | 1653,4 | 5647 | 1422,9 | 2,14 | 7,29 | 1,84 | 774,1 | 3,55 | 36,36 |
0 / 32 | 2050,8 | 7004 | 1765,0 | 2,40 | 8,18 | 2,06 | 856,0 | 3,94 | 45,35 | |
5 / 41 | 2513,8 | 8585 | 2163,4 | 2,67 | 9,12 | 2,30 | 941,1 | 4,38 | 55,96 | |
cond. pressure pc= 55/131 | -20 / -4 | 656,9 | 2244 | 565,4 | 1,17 | 3,99 | 1,00 | 562,6 | 2,63 | 15,76 |
-15 / 5 | 870,2 | 2972 | 748,9 | 1,35 | 4,60 | 1,16 | 646,4 | 3,01 | 20,95 | |
return gas temp. RGT= 32/90 | -10 / 14 | 1118,3 | 3819 | 962,5 | 1,52 | 5,20 | 1,31 | 735,1 | 3,42 | 27,04 |
liquid temp Tliq= 55/131 | -6,7 / 20 | 1304,6 | 4455 | 1122,8 | 1,64 | 5,59 | 1,41 | 796,6 | 3,71 | 31,65 |
-5 / 23 | 1408,3 | 4810 | 1212,0 | 1,70 | 5,80 | 1,46 | 829,1 | 3,86 | 34,23 | |
0 / 32 | 1747,3 | 5967 | 1503,7 | 1,88 | 6,43 | 1,62 | 928,7 | 4,35 | 42,74 | |
5 / 41 | 2142,6 | 7317 | 1844,0 | 2,07 | 7,08 | 1,78 | 1034,0 | 4,86 | 52,80 |
Configuration 2: General and Operating Conditions
Configuration Details
- Motorconfiguration: CSCR
- Power supply (nominal): 220-240V/50Hz 1~
- Refrigerant: R513A
- Application: MBP
- Voltage range: 198-254V
- Starting torque: HST
- Approvals: VDE, CCC
Ambient Temperatures / System Cooling
Ambient temperature min.: 10°C / 50°F
Ambient temperature max.: 43°C / 110°F
T ambient | LBP | MBP | HBP |
---|---|---|---|
32°C / 90°F | n/a | fan 3m/s | n/a |
38°C / 100°F | n/a | fan 3m/s | n/a |
43°C / 110°F | n/a | fan 3m/s | n/a |
Operation Pressure Range
Graph showing the relationship between condensing pressure (y-axis) and evaporation pressure (x-axis) for continuous and transitory operation, with temperature scales in Celsius and Fahrenheit.
Evaporation Pressure
Graph showing evaporation pressure (x-axis) versus condensing pressure (y-axis) for continuous and transitory operation.
Electrical Accessories / Wiring Diagram
Wiring diagram for the compressor, showing connections for motor windings (S, R, C), starter, capacitor, thermostat, and fan. Includes terminal designations and a key for wire colors (English column shown).
Component | Code |
---|---|
a3 GS starter kit (600mm) | 117-7055 |
b cover | 107B9101 |
b2 gasket | 107B9100 |
b1 clamp | 107B9104 |
Configuration 2: Optimization and Standard Conditions
RGT | Tliq | Cooling capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | Ref. mass flow m [kg/h] | Standard | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pe [°C] | pc [°C] | ||||||||||||
-6,66 | 54,4 | 35 | 46,1 | 1535,4 | 5244 | 1321,4 | 1,81 | 6,18 | 1,56 | 848,3 | 3,97 | 37,61 | ASHRAE MBP |
[°F] | [°F] | 95 | 115 | ||||||||||
-10 | 55 | 32 | 55 | 1172,9 | 4006 | 1009,4 | 1,49 | 5,08 | 1,28 | 788,7 | 3,69 | 32,43 | cecomaf MBP |
[°F] | [°F] | 89,6 | 131 | ||||||||||
-10 | 45 | 20 | 45 | 1333,2 | 4553 | 1147,4 | 1,79 | 6,12 | 1,54 | 743,4 | 3,48 | 35,34 | EN12900 MBP |
[°F] | [°F] | 68 | 113 | ||||||||||
-6,66 | 48,9 | 18,3 | 48,9 | 1435,6 | 4903 | 1235,5 | 1,76 | 6,01 | 1,51 | 816,5 | 3,82 | 40,45 | ARI540 MBP |
[°F] | [°F] | 120 | 65 | 120 | |||||||||
-10 | 45 | 32 | 45 | 1395,4 | 4766 | 1200,9 | 1,88 | 6,41 | 1,62 | 743,4 | 3,48 | 34,31 | opt |
[°F] | [°F] | 113 | 89,6 | 113 | |||||||||
-25 | 45 | 32 | 45 | 634,1 | 2165 | 545,7 | 1,22 | 4,16 | 1,05 | 520,0 | 2,46 | 15,45 | opt |
[°F] | [°F] | 113 | 89,6 | 113 |
Configuration 2: Performance Tables
Cooling capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | m [kg/h] | ||
---|---|---|---|---|---|---|---|---|---|---|
[°C / °F] | ||||||||||
cond. pressure pc= 45/113 | -20 / -4 | 849,2 | 2900 | 730,8 | 1,43 | 4,90 | 1,23 | 592,2 | 2,79 | 20,75 |
-15 / 5 | 1100,8 | 3759 | 947,4 | 1,65 | 5,64 | 1,42 | 666,5 | 3,13 | 26,97 | |
return gas temp. RGT= 32/90 | -10 / 14 | 1395,4 | 4766 | 1200,9 | 1,88 | 6,41 | 1,62 | 743,4 | 3,48 | 34,31 |
liquid temp Tliq= 45/113 | -6,7 / 20 | 1616,5 | 5521 | 1391,2 | 2,03 | 6,94 | 1,75 | 795,6 | 3,72 | 39,85 |
-5 / 23 | 1739,4 | 5940 | 1496,9 | 2,11 | 7,22 | 1,82 | 823,1 | 3,85 | 42,94 | |
0 / 32 | 2139,4 | 7306 | 1841,2 | 2,36 | 8,07 | 2,03 | 905,9 | 4,23 | 53,06 | |
5 / 41 | 2602,0 | 8886 | 2239,3 | 2,62 | 8,96 | 2,26 | 992,1 | 4,63 | 64,90 | |
cond. pressure pc= 55/131 | -20 / -4 | 707,0 | 2415 | 608,4 | 1,15 | 3,93 | 0,99 | 614,5 | 2,89 | 19,41 |
-15 / 5 | 923,5 | 3154 | 794,8 | 1,32 | 4,51 | 1,14 | 698,9 | 3,28 | 25,44 | |
return gas temp. RGT= 32/90 | -10 / 14 | 1172,9 | 4006 | 1009,4 | 1,49 | 5,08 | 1,28 | 788,7 | 3,69 | 32,43 |
liquid temp Tliq= 45/113 | -6,7 / 20 | 1358,8 | 4640 | 1169,4 | 1,60 | 5,45 | 1,37 | 851,0 | 3,98 | 37,68 |
-5 / 23 | 1461,8 | 4992 | 1258,1 | 1,65 | 5,65 | 1,42 | 884,1 | 4,13 | 40,61 | |
0 / 32 | 1796,8 | 6137 | 1546,4 | 1,82 | 6,23 | 1,57 | 985,5 | 4,60 | 50,18 | |
5 / 41 | 2184,7 | 7461 | 1880,1 | 2,00 | 6,83 | 1,72 | 1093,1 | 5,09 | 61,39 |
Wiring and Terminal Information
GS Compressors - Wiring Diagram
Diagram illustrating the GS compressor assembly, showing key components and orientation. Includes a detailed wiring diagram with terminal designations (S, C, R) and color codes for different regions (English column shown).
Terminal Color Codes
ENGLISH | DEUTSCH | FRANÇAIS | ESPAÑOL | ITALIANO | NEDERLANDS | DANSK | SVENSKA | SUOMEKSI | РУССКИЙ | 中文 |
---|---|---|---|---|---|---|---|---|---|---|
Black | Schwarz | Noir | Negro | Nero | Zwart | Sort | Svart | Musta | Чёрный | 黑色 |
Brown | Braun | Marron | Marrón | Marrone | Bruin | Brun | Brun | Ruskea | Корич-невый | 棕色 |
Blue or grey | Blau od. grau | Bleu ou gris | Azul o gris | Blu o grigio | Blauw of grijs | Blå eller grå | Blå eller grå | Sininen tai harmaa | Синий или серый | 蓝色或灰色 |
Secop GmbH. Lise-Meitner-Straße 29 • 24941 Flensburg, Germany • Tel: +49 461 49410 • www.secop.com
Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.