User Manual for DURATECH models including: DVS050, DVS100, DVS170, DVM050, DVM100, DVM170, Vision Spectra LED Light
Table of contents. Technical specifications Remarks Box contents Installation instructions Wiring instructions setup 1 Wiring instructions setup 2 Retrofit in PAR56 niche (only Vision Spectra 170mm)...
6 Box contents Retrofit Kit (only for 170mm models) Vision Spectra lamp (50,100 or 170 mm) 2m Cable (2x1mm2) Connection Kit Vision Spectra ( 513-0228 ) Manual
File Info : application/pdf, 20 Pages, 1.27MB
DocumentDocumentManual DVS050 DVS100 DVS170 DVM050 DVM100 DVM170 Visit www.duratech.be for other available languages 23-09-21 2 Table of contents Technical specifications Remarks Box contents Installation instructions Wiring instructions setup 1 Wiring instructions setup 2 Retrofit in PAR56 niche (only Vision Spectra 170mm) Color programs Synchronizing & color changing Color locking Troubleshooting Page 4 Page 5 Page 6 Page 7-8-9 Page 10-11 Page 12-13 Page 14 Page 15 Page 16 Page 17 Page 18 3 ENG Technical specifications Lamp Type DVS050-RGB DVS050-TW DVS050-WH DVM050-WH Description RGB color 50 mm Tunable white 50mm Day white 50mm Low Day white 50mm Voltage 10-14 VAC 10-14 VAC 10-14 VAC 10-14 VAC Power 8 W 8 W 10 W 5 W Color temp All colors 2000-17500K 5000K 5000K Luminous flux* 450 lm 550 lm 700 lm 375 lm DVS100-RGB DVS100-TW DVS100-WH DVM100-WH RGB color 100mm Tunable white 100mm Day white 100mm Low Day white 100mm 10-14 VAC 10-14 VAC 10-14 VAC 10-14 VAC 20 W 20 W 26 W 9 W All colors 2000-17500K 5000K 5000K 1550 lm 1500 lm 2300 lm 875 lm DVS170-RGB DVS170-TW DVS170-WH DVM170-WH DVM170-RGB RGB color 170mm Tunable white 170mm Day white 170mm Low Day white 170mm Low RGB color 170mm 10-14 VAC 10-14 VAC 10-14 VAC 10-14 VAC 10-14 VAC 32 W 32 W 40 W 17 W 20 W All colors 2000-17500K 5000K 5000K All colors 2450 lm 2400 lm 3950 lm 1675 lm 1600 lm (*) Propulsion systems remains a tolerance of +/- 10% on luminous flux measurements @ 25°C ; 12VAC For operation only with a safety isolation transformer Minimum input voltage: (at lamp terminals) Nominal input voltage: (at lamp terminals) Maximum input voltage: (at lamp terminals) 10 VAC 50 Hz 12 VAC 50 Hz 14 VAC 50 Hz IEC Protection Class III Operation on DC voltages is NOT allowed Maximum water temperature: +40°C Lamps have to be kept out of ice zones Ingress protection rate: IP68 measured at 3m max depth = 3m 4 ENG Remarks Water conditions Prevent damage to your pool lamps and wires due to unstable water conditions. Your local government may have enacted guidelines for your pool water conditions to apply by. If not we strongly advise the following parameter specifications to be applied: pH level Free Chlorine Combined chlorine Water temperature 6,8 - 7,6 max. 3ppm max. 1 ppm max +40°C and lamps need to be kept out of ice zones Always adhere to the instructions provided by your chemical brand/supplier for the correct use and application of pool chemicals. Salt water pools, or pools fitted with a salt water chlorine generator contain salt in the pool water. Salt is a corrosive material. Overdosage and/or consistent levels of salt increase the possibility of deterioration of your pool lamps and cables. As a rule of thumb, a concentration of 35gr/l salt can be accepted when pH values are between 7,2-7,4. In any case, we urge proper use, care and maintenance of your installation, in order to minimize the effect of corrosion and deterioration. Please be aware that pool lamps and cables with defects caused due to abnormalities in the water condition are not covered by our factory warranty. 5 Installation/maintenance The luminaire is maintenance free If the luminaire needs to be replaced, it needs to be completely removed from the water If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively ! replaced by the manufacturer or his service agent or a similar qualified person in order to avoid hazard Vision Spectra Pool lamps must be completely submerged into water during operation. ! Fixing the lamps with adhesives or silicone kit into a niche is not allowed Not following these instructions, will void warranty. Box contents Vision Spectra lamp (50,100 or 170 mm) Manual Connection Kit Vision Spectra ( 513-0228 ) 2m Cable (2x1mm2) Retrofit Kit (only for 170mm models) 6 mounting face plate Toolset ( not included ) Contact your local distributor for a toolset (513-0151) Lamp Face Plate Installation instructions mounting the connector 2m Cable Fix Nut Washers (3x) Fix Nut Silicone Gasket Connector ! Details: Page 8 & 9 7 ENG Connector installation 1 2 3 8 ENG 4 5 6 9 Wiring instructions Setup 1 For new installations Each lamp is connected to the transformer by a separate cable Pool Pool house SELECT CABLE SECTION & MAXIMUM LENGTH 2m cable included in lamp package Separate cable ( not included ) ! Always use a toroïdal transformer 10 ENG LAMP TYPE DVS050-TW DVS050-RGB DVS050-WH DVM050-WH DVS100-TW DVS100-RGB DVS100-WH DVM100-WH SELECT CABLE SECTION & MAXIMUM LENGTH 1,5mm2 2,5mm2 4,0mm2 6,0mm2 10mm2 VA TRANSFORMER (12VAC)* 75m 125m 200m 300m 500m 150m 250m 400m 600m 1000m 13 VA 7 VA 25m 45m 75m 115m 195m 85m 140m 200m 300m 550m 34 VA 12 VA DVS170-TW DVS170-RGB DVS170-WH DVM170-WH DVM170-RGB 20m 30m 50m 75m 125m 45m 75m 120m 180m 300m 35m 60m 100m 150m 250m 52 VA 22 VA 26 VA STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE * The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps. These cable lenghts are calculated with worst case voltage drops in the electrical wiring. 11 Wiring instructions Setup 2 For existing or other installations All lamps are connected to the transformer via 1 cable Pool Pool house SELECT CABLE SECTION & MAXIMUM LENGTH 2m cable included in lamp package Separate cable ( not included ) ! Always use a toroïdal transformer 12 ENG LAMP TYPE SELECT CABLE SECTION & MAXIMUM LENGTH QTY 2,5mm2 4,0mm2 6,0mm2 10mm2 VA TRANSFORMER (12VAC) DVS050-TW DVS050-RGB DVS050-WH 1 125m 200m 300m 500m 13 2 63m 100m 150m 250m 26 3 42m 67m 100m 167m 39 4 31m 50m 75m 125m 52 DVM050-WH 1 250m 400m 600m 1000m 7 2 125m 200m 300m 500m 14 3 83m 133m 200m 333m 21 4 63m 100m 150m 250m 28 DVS100-TW DVS100-RGB DVS100-WH 1 45m 75m 115m 195m 34 2 23m 38m 58m 98m 68 3 15m 25m 38m 65m 102 4 11m 19m 29m 49m 136 DVM100-WH 1 140m 200m 300m 550m 12 2 70m 100m 150m 275m 24 3 47m 67m 100m 183m 36 4 35m 50m 75m 138m 48 DVS170-TW DVS170-RGB DVS170-WH 1 30m 50m 75m 125m 52 2 15m 25m 38m 63m 104 3 10m 17m 25m 42m 156 4 8m 13m 19m 31m 208 DVM170-WH 1 75m 120m 180m 300m 22 2 38m 60m 90m 150m 44 3 25m 40m 60m 100m 66 4 19m 30m 45m 75m 88 DVM170-RGB 1 60m 100m 150m 250m 26 2 30m 50m 75m 125m 52 3 20m 33m 50m 83m 78 4 15m 25m 38m 63m 104 STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE 13 Retrofit in PAR56 niche (only Vision Spectra 170mm) 1 2 3 14 ENG Color programs RGB LAMPS 1 CANDLE LIGHT 2 WARM WHITE 3 NEUTRAL WHITE 4 COLD WHITE 5 CARIBEAN BLUE 6 BLUE 7 GREEN 8 RED 9 PURPLE 10 YELLOW DYNAMIC 11 BLUE DYNAMIC 2000K very warm white 3000K warm white 5000K neutral white 9500K cold white cyan blue green red purple slow animation yellow fast animation blue TW LAMPS 1 CANDLE LIGHT 2 WARM WHITE 3 NEUTRAL WHITE 4 COLD WHITE 5 BLUE-WHITE 6 COOL BLUE 2000K 3000K 5000K 9500K 13500K 17500K 15 Synchronizing & color changing (for RGB and TW lamps only) Manual synchronization 1. Switch ON the 12 VAC line voltage and make sure that all lamps light up. 2. Switch OFF the 12 VAC line voltage and wait for at least 20 sec (max 60 sec) 3. Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF) 4. Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF) 5. Switch ON 6. The lamps should now all be on color program 6: Blue * TW lamps: the lamps will all flicker after 15 seconds on color program 6. You can now choose to lock the lamp on a desired color program by switching off/on within the next 5 seconds. After 5 seconds the flickering will stop and the lamp is locked. See next page for details. If you did not select a color when flickering, the lamps will stop flickering after 5 seconds and the lamp will be unlocked. Changing colors Quickly turn the lamps OFF and back ON The lamp will jump to the next color program Memorizing the actual color Turn the lamp OFF for MINIMUM 20 seconds The last chosen color has now been memorized 16 ENG Color Locking (only for TW lamps) If desired, TW lamps can be "locked" on a color program of choice. This means the lamp will only light up in that specific color, and it is no longer possible to change the color program of the lamp. This process can be reversed anytime by "unlocking" the color program. All color programs will then be available again, and can be changed at any time. Locking/Unlocking procedure Locking the color of a lamp starts with a synchronisation procedure: 1. Switch ON the 12 VAC line voltage 2. Switch OFF the 12 VAC line voltage and wait for at least 20 sec (max 60 sec) 3. Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF) 4. Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF) 5. Switch ON 6. Wait for about 15 seconds. The lamp(s) will now flicker LOCKING: - during the flickering of the lamp, select the desired color program by switching (within 5 seconds) the lamps OFF and ON quickly. - When the right color is selected, then wait 5 seconds, until the flickering stops - The lamp is now locked on the chosen color program UNLOCKING: - When the lamps flicker, then do nothing for 5 seconds. - The flickering will stop, and it is again possible to change the color program of the lamps. 17 Troubleshooting PROBLEM . The pool light is flickering . Several pool lights in the pool show different color programs 18 SOLUTION 1. Switch the lamps ON and select Cold white color program 2. Remove the lamp from the water, unscrew the fix nut, pull back the gasket and the black cable jacket, so you can reach the brass contacts inside the connector block (do not remove the connector block) 3. Measure the voltage at the lamp terminals (while the lamp is still ON) 4. The voltage at the lamp should be at least 10VAC 50Hz. If the measured line voltage is below 10VAC: A. Check the output voltage at the transformator terminals. This voltage should be between 12VAC and 14VAC. Verify that the used transformator VA rating is sufficient for powering all connected lamps B. If the transformator output voltage is ok, then install a thicker cable between the transformator and the lamp. (wiring instructions p. 10-13) In case of TW lamps: make sure the lamp is not in color locking mode Make sure that all lamps are connected to the same 12VAC power line. Execute the synchronization as explained on p.16 ENG Declaraction of Conformity Declarations of conformity covering this product are available for download from the House of Duratech website: www.duratech.be DURAVISION Pool Light Products VISION Moonlight VISION Spectra VISION Adagio Pro VISION Pro VISION Wall Conduits VISION Faces Plates VISION Specials DURALINK Control Products LINK Driver LINK Touch LINK Controller LINK Master LINK Accessoires LINK Cover DURAHEAT Heat Pump Products HEAT Hot Splash HEAT Sun Spring HEAT Dura V HEAT Dura Vi HEAT Dura +i HEAT Dura Pro HEAT Accessories DURACOVER DURAFLOW Pool Cover Products Pool Flow Products COVER Wall Duct COVER Cable Duct COVER Hanging System FLOW Inverter 19 Contact details Propulsion Systems bv Dooren 72 1785 Merchtem, Belgium Tel +32 2 461 02 53 www.duratech.be info@propulsionsystems.be We reserve the rights to change all or part of the contents of this document without prior notice 20 402-0040-3