User Manual for DURATECH models including: DVS050, DVS100, DVS170, DVM050, DVM100, DVM170, Vision Spectra LED Light

PDF Manual

Table of contents. Technical specifications Remarks Box contents Installation instructions Wiring instructions setup 1 Wiring instructions setup 2 Retrofit in PAR56 niche (only Vision Spectra 170mm)...

Manual - duratech.be

6 Box contents Retrofit Kit (only for 170mm models) Vision Spectra lamp (50,100 or 170 mm) 2m Cable (2x1mm2) Connection Kit Vision Spectra ( 513-0228 ) Manual


File Info : application/pdf, 20 Pages, 1.27MB

PDF preview unavailable. Download the PDF instead.

1644492198402-0040-3-Artwork
Manual DVS050 DVS100 DVS170 DVM050 DVM100 DVM170
Visit www.duratech.be for other available languages

23-09-21

2

Table of contents
Technical specifications Remarks Box contents Installation instructions Wiring instructions setup 1 Wiring instructions setup 2 Retrofit in PAR56 niche (only Vision Spectra 170mm) Color programs Synchronizing & color changing Color locking Troubleshooting

Page 4 Page 5 Page 6 Page 7-8-9 Page 10-11 Page 12-13 Page 14 Page 15 Page 16 Page 17 Page 18
3

ENG

Technical specifications

Lamp Type
DVS050-RGB DVS050-TW DVS050-WH DVM050-WH

Description
RGB color 50 mm Tunable white 50mm Day white 50mm Low Day white 50mm

Voltage
10-14 VAC 10-14 VAC 10-14 VAC 10-14 VAC

Power
8 W 8 W 10 W 5 W

Color temp
All colors 2000-17500K 5000K 5000K

Luminous flux*
450 lm 550 lm 700 lm 375 lm

DVS100-RGB DVS100-TW DVS100-WH DVM100-WH

RGB color 100mm Tunable white 100mm Day white 100mm Low Day white 100mm

10-14 VAC 10-14 VAC 10-14 VAC 10-14 VAC

20 W 20 W 26 W
9 W

All colors 2000-17500K 5000K 5000K

1550 lm 1500 lm 2300 lm
875 lm

DVS170-RGB DVS170-TW DVS170-WH DVM170-WH DVM170-RGB

RGB color 170mm Tunable white 170mm Day white 170mm Low Day white 170mm Low RGB color 170mm

10-14 VAC 10-14 VAC 10-14 VAC 10-14 VAC 10-14 VAC

32 W 32 W 40 W 17 W 20 W

All colors 2000-17500K 5000K 5000K All colors

2450 lm 2400 lm 3950 lm 1675 lm 1600 lm

(*) Propulsion systems remains a tolerance of +/- 10% on luminous flux measurements @ 25°C ; 12VAC

For operation only with a safety isolation transformer

Minimum input voltage: (at lamp terminals)
Nominal input voltage: (at lamp terminals)
Maximum input voltage: (at lamp terminals)

10 VAC 50 Hz 12 VAC 50 Hz 14 VAC 50 Hz

IEC Protection Class III

Operation on DC voltages is NOT allowed

Maximum water temperature: +40°C
Lamps have to be kept out of ice zones

Ingress protection rate:

IP68
measured at 3m max depth = 3m

4

ENG

Remarks

Water conditions
Prevent damage to your pool lamps and wires due to unstable water conditions. Your local government may have enacted guidelines for your pool water conditions to apply by. If not we strongly advise the following parameter specifications to be applied:

pH level Free Chlorine Combined chlorine Water temperature

6,8 - 7,6 max. 3ppm max. 1 ppm max +40°C and lamps need to be kept out of ice zones

Always adhere to the instructions provided by your chemical brand/supplier for the correct use and application of pool chemicals.

Salt water pools, or pools fitted with a salt water chlorine generator contain salt in the pool water. Salt is a corrosive material. Overdosage and/or consistent levels of salt increase the possibility of deterioration of your pool lamps and cables. As a rule of thumb, a concentration of 35gr/l salt can be accepted when pH values are between 7,2-7,4. In any case, we urge proper use, care and maintenance of your installation, in order to minimize the effect of corrosion and deterioration.

Please be aware that pool lamps and cables with defects caused due to abnormalities in the water condition are not covered by our factory warranty.

5

Installation/maintenance
The luminaire is maintenance free If the luminaire needs to be replaced, it needs to be completely removed from the water
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively
! replaced by the manufacturer or his service agent or a similar qualified person in order
to avoid hazard
Vision Spectra Pool lamps must be completely submerged into water during operation.
! Fixing the lamps with adhesives or silicone kit into a niche is not allowed
Not following these instructions, will void warranty.

Box contents
Vision Spectra lamp (50,100 or 170 mm)

Manual

Connection Kit Vision Spectra
( 513-0228 )

2m Cable (2x1mm2)

Retrofit Kit (only for 170mm models)

6

mounting face plate
Toolset ( not included ) Contact your local distributor for a toolset (513-0151)
Lamp
Face Plate

Installation instructions
mounting the connector
2m Cable Fix Nut Washers (3x)
Fix Nut

Silicone Gasket Connector

!
Details: Page 8 & 9

7

ENG

Connector installation

1

2

3

8

ENG

4

5

6

9

Wiring instructions Setup 1
For new installations Each lamp is connected to the transformer by a separate cable
Pool
Pool house

SELECT CABLE SECTION & MAXIMUM LENGTH

2m cable included in lamp package Separate cable ( not included )

! Always use a toroïdal transformer

10

ENG

LAMP TYPE
DVS050-TW DVS050-RGB DVS050-WH DVM050-WH
DVS100-TW DVS100-RGB DVS100-WH DVM100-WH

SELECT CABLE SECTION & MAXIMUM LENGTH
1,5mm2 2,5mm2 4,0mm2 6,0mm2 10mm2 VA TRANSFORMER (12VAC)*

75m 125m 200m 300m 500m 150m 250m 400m 600m 1000m

13 VA 7 VA

25m 45m 75m 115m 195m 85m 140m 200m 300m 550m

34 VA 12 VA

DVS170-TW DVS170-RGB DVS170-WH
DVM170-WH
DVM170-RGB

20m 30m 50m 75m 125m
45m 75m 120m 180m 300m 35m 60m 100m 150m 250m

52 VA
22 VA 26 VA

STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE

* The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps. These cable lenghts are calculated with worst case voltage drops in the electrical wiring.

11

Wiring instructions Setup 2
For existing or other installations All lamps are connected to the transformer via 1 cable

Pool

Pool house

SELECT CABLE SECTION & MAXIMUM LENGTH

2m cable included in lamp package Separate cable ( not included )

! Always use a toroïdal transformer

12

ENG

LAMP TYPE

SELECT CABLE SECTION & MAXIMUM LENGTH
QTY 2,5mm2 4,0mm2 6,0mm2 10mm2

VA TRANSFORMER (12VAC)

DVS050-TW DVS050-RGB DVS050-WH

1

125m 200m 300m

500m

13

2

63m 100m

150m

250m

26

3

42m

67m 100m

167m

39

4

31m

50m

75m

125m

52

DVM050-WH

1

250m 400m 600m 1000m

7

2

125m 200m 300m

500m

14

3

83m

133m 200m

333m

21

4

63m 100m

150m

250m

28

DVS100-TW DVS100-RGB DVS100-WH

1

45m

75m

115m

195m

34

2

23m

38m

58m

98m

68

3

15m

25m

38m

65m

102

4

11m

19m

29m

49m

136

DVM100-WH

1

140m 200m 300m

550m

12

2

70m

100m

150m

275m

24

3

47m

67m 100m

183m

36

4

35m

50m

75m

138m

48

DVS170-TW DVS170-RGB DVS170-WH

1

30m

50m

75m

125m

52

2

15m

25m

38m

63m

104

3

10m

17m

25m

42m

156

4

8m

13m

19m

31m

208

DVM170-WH

1

75m

120m

180m

300m

22

2

38m

60m

90m

150m

44

3

25m

40m

60m

100m

66

4

19m

30m

45m

75m

88

DVM170-RGB

1

60m 100m

150m

250m

26

2

30m

50m

75m

125m

52

3

20m

33m

50m

83m

78

4

15m

25m

38m

63m

104

STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE

13

Retrofit in PAR56 niche (only Vision Spectra 170mm) 1 2 3
14

ENG

Color programs
RGB LAMPS

1 CANDLE LIGHT 2 WARM WHITE 3 NEUTRAL WHITE 4 COLD WHITE 5 CARIBEAN BLUE 6 BLUE 7 GREEN 8 RED 9 PURPLE 10 YELLOW DYNAMIC 11 BLUE DYNAMIC

2000K very warm white 3000K warm white 5000K neutral white 9500K cold white cyan blue green red purple slow animation yellow fast animation blue

TW LAMPS

1 CANDLE LIGHT 2 WARM WHITE 3 NEUTRAL WHITE 4 COLD WHITE 5 BLUE-WHITE 6 COOL BLUE

2000K 3000K 5000K 9500K 13500K 17500K

15

Synchronizing & color changing (for RGB and TW lamps only)
Manual synchronization 1. Switch ON the 12 VAC line voltage and make sure that all lamps light up. 2. Switch OFF the 12 VAC line voltage and wait for at least 20 sec (max 60 sec) 3. Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF) 4. Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF) 5. Switch ON 6. The lamps should now all be on color program 6: Blue
* TW lamps: the lamps will all flicker after 15 seconds on color program 6. You can now choose to lock the lamp on a desired color program by switching off/on within the next 5 seconds. After 5 seconds the flickering will stop and the lamp is locked. See next page for details. If you did not select a color when flickering, the lamps will stop flickering after 5 seconds and the lamp will be unlocked.
Changing colors Quickly turn the lamps OFF and back ON The lamp will jump to the next color program
Memorizing the actual color Turn the lamp OFF for MINIMUM 20 seconds The last chosen color has now been memorized
16

ENG

Color Locking (only for TW lamps)
If desired, TW lamps can be "locked" on a color program of choice. This means the lamp will only light up in that specific color, and it is no longer possible to change the color program of the lamp. This process can be reversed anytime by "unlocking" the color program. All color programs will then be available again, and can be changed at any time.
Locking/Unlocking procedure Locking the color of a lamp starts with a synchronisation procedure: 1. Switch ON the 12 VAC line voltage 2. Switch OFF the 12 VAC line voltage and wait for at least 20 sec (max 60 sec) 3. Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF) 4. Switch ON and switch OFF (max 3 sec ON and max 3 sec OFF) 5. Switch ON 6. Wait for about 15 seconds. The lamp(s) will now flicker
LOCKING: - during the flickering of the lamp, select the desired color program by switching (within 5 seconds) the lamps OFF and ON quickly.
- When the right color is selected, then wait 5 seconds, until the flickering stops
- The lamp is now locked on the chosen color program
UNLOCKING: - When the lamps flicker, then do nothing for 5 seconds. - The flickering will stop, and it is again possible to change the color program of the lamps.
17

Troubleshooting
PROBLEM
. The pool light is flickering
. Several pool lights in the
pool show different color programs 18

SOLUTION
1. Switch the lamps ON and select Cold white color program 2. Remove the lamp from the water, unscrew the fix nut,
pull back the gasket and the black cable jacket, so you can reach the brass contacts inside the connector block (do not remove the connector block) 3. Measure the voltage at the lamp terminals (while the lamp is still ON) 4. The voltage at the lamp should be at least 10VAC 50Hz. If the measured line voltage is below 10VAC:
A. Check the output voltage at the transformator terminals. This voltage should be between 12VAC and 14VAC. Verify that the used transformator VA rating is sufficient for powering all connected lamps
B. If the transformator output voltage is ok, then install a thicker cable between the transformator and the lamp. (wiring instructions p. 10-13)
In case of TW lamps: make sure the lamp is not in color locking mode
Make sure that all lamps are connected to the same 12VAC power line. Execute the synchronization as explained on p.16

ENG

Declaraction of Conformity
Declarations of conformity covering this product are available for download from the House of Duratech website: www.duratech.be

DURAVISION
Pool Light Products
VISION Moonlight VISION Spectra VISION Adagio Pro VISION Pro VISION Wall Conduits VISION Faces Plates VISION Specials

DURALINK
Control Products
LINK Driver LINK Touch LINK Controller LINK Master LINK Accessoires LINK Cover

DURAHEAT
Heat Pump Products
HEAT Hot Splash HEAT Sun Spring HEAT Dura V HEAT Dura Vi HEAT Dura +i HEAT Dura Pro HEAT Accessories

DURACOVER DURAFLOW

Pool Cover Products

Pool Flow Products

COVER Wall Duct COVER Cable Duct COVER Hanging System

FLOW Inverter

19

Contact details
Propulsion Systems bv Dooren 72
1785 Merchtem, Belgium Tel +32 2 461 02 53 www.duratech.be
info@propulsionsystems.be
We reserve the rights to change all or part of the contents of this document without prior notice
20

402-0040-3



References

Adobe PDF Library 16.0 Adobe InDesign 16.4 (Macintosh)