Berg BERT3R 64.9 cu.ft. 3-Door Top Mount Reach-In Refrigerator 78"W | Restaurant Equippers
Content: 1.Preface................................................................2 2.Useoftheequipment..........................................5 3.Technicalfeatures...............................................5 4.Operation............................................................5 5.Controlunit..........................................................6 6.Handling..............................................................6 7.Installation procedure..........................................7 8.Connectingtothemainpowersupply.................7 9.Maintenanceinstructions....................................8 Cleaning............................................................8 Cleaningtherefrigeratorsurface......................8 Cleaningtheinsideoftherefrigerator...............9 Cleaning the condenser....................................9 10.Troubleshooting................................................9 11.Technicalservice..............................................9 12.ConfigurationSketchMap...............................10 Operating Instruction............................................10 OfficialApprovalAndRules.................................15 TechnicalParameters..........................................16 ATTENTION.........................................................18 1 1.Preface Please read instructions before using this appliance. IMPORTANT SAFETY INSTRUCTION Toreducetheriskoffire,electricshock,orinjurytopersonswhen usingyourproduct,basicsafetyprecautionsshouldbefollowed, including the following. Thisappliancemustbeproperlyinstalledandlocatedinaccordance withtheInstallationInstructionbeforeitisused. Beforetheapplianceispluggedin,ensurethattheratedvoltage correspondstothevoltageoftheelectricalsystem inyourhome.The powerplugshouldhaveitsownindependentsocket.Usingadapters maycauseoverheatingorburning. Thisappliancecanbeusedbychildrenagedfrom 8yearsandabove andpersonswithreducedphysical,sensoryormentalcapabilitiesor lackofexperienceandknowledgeiftheyhavebeengivensupervision orinstructionconcerninguseoftheapplianceinasafewayand understand the hazards involved. Childrenshallnotplaywiththeappliance. Cleaningandusermaintenanceshallnotbemadebychildrenwithout supervision. Ifthesupplycordisdamaged,itmustbereplacedbythemanufacturer oritsserviceagentorasimilarlyqualifiedpersoninordertoavoida hazard. Connecttoproperlygroundedoutletsonly.Avoidtheuseofextension cords.Donotruncordundercarpeting,runnersorthelike.Arrange cordawayfrom trafficareaandwhereitwillnotcreateatrippinghazard. Alwaysunplugappliancewhennotinuseandbeforecleaning, adjustingormaintainingthismachine.Todisconnectappliance,turn switchoffandremoveplugfrom powersource. 2 Donotdisconnectbypullingonthecord.Alwaysdisconnectbygrasping and pulling on the plug top. Donotpulloutthecordortouchthepowerplugwithwethands.Clean waterordustfrom thepowerplugandinsertitwiththeendsofthepins securely connected. Donotuseoutdoors. Donotsplashwaterontheappliance.Itmaycauseamalfunctionor electric shock. Donotdisassemble,repairoraltertheappliance.Itmaycausefireor abnormaloperations,whichmayleadtoinjury. Afteryourfridge-freezerisinoperation,donottouchthecoldsurfacesin thefreezercompartment,particularlywhenhandsaredamporwet.Skin mayadheretotheseextremelycoldsurfaces. Neverplaceglassproductsinthefreezerbecausetheymaybebroken whentheirinnercontentsarefrozen. Therefrigerantandinsulationblowinggasusedintheappliancerequire specialdisposalprocedures.Whendisposal,pleaseconsultwithservice agentorasimilarlyqualifiedperson. Donotstoreexplosivesubstancessuchasaerosolcanswitha flammablepropellantinthisappliance. WARNING:Keepclearofobstructionallventilationopeningsinthe appliance enclosure or in the structure for building-in. WARNING:Donotusemechanicaldevicesorothermeanstoaccelerate thedefrostingprocess,otherthanthoserecommendedbythe manufacturer. WARNING:Donotdamagetherefrigerantcircuit. WARNING:Donotuseelectricalappliancesinsidethefoodstorage compartmentsoftheappliance,unlesstheyareofthetyperecommended bythemanufacturer. 3 Warning:Riskoffire/flammablematerials CAUTION:RISK OFFIREAND EXPLOSION WITH FLAMMABLE REFRIGERANT R290. Ifyouneedtheelectronicversioninstructionmanual,pleaseaskthe manufactureroritsserviceagent. Max.Loadofshelfis80Kg. Thisinstructionmanualprovidesallthenecessaryinformationregarding: useoftherefrigerator technicalspecifications installationandhandling operatorproceduresandinstructions maintenanceoperation Themanualistobeconsideredanintegralpartoftherefrigeratorand shouldbestoredinasafeplaceforfatherconsulttopermitagood workinglifeoftherefrigerator. Theapplianceisintendedforcommercialuseonly. Componentpartsshallbereplacedwithlikecomponentsandthat servicingshallbedonebyfactoryauthorizedservicepersonnel. Themanufacturercannotbeheldliableinthefollowing cases: improperinstallation(notinaccordancewiththeguidelinesindicated herein) misuseoftherefrigerator powersupplydefects improperorinadequatemaintenance unauthorisedmodificationortampering useofnon-originalspareparts partialortotalfailuretocomplywiththeinstructions Allelectricalequipmentcanbehazardoustohealth.Currentstandards andlegalrequirementsmustbecompliedwithduringtheinstallationand useofanyequipment. 4 2.Useoftheequipment This fridge/freezer is designed for cooling/freezing fresh perishable foodstuffs in restaurants, canteens and similar catering establishments. Do not utilise the equipment to store medical supplies. The optimum operational ambient temperatures are between +10~ +40. 3.Technicalfeatures Therefrigeratorisaventilatedsystem,theevaporatorisinaseparate insulatedboxonthetop.Allthematerialsusedinthemanufactureof thisunitareguaranteedtobesuitableforusewithfoodstuffs.The gasesusedinproducesisR290.Therefrigeratingcircuitareincompliance withthecurrentnormative. 4.Operation Thegasintherefrigeratingcircuitisinthefirsttimecompressed, liquefiedandthenevaporatedintheventilatedevaporator,situatedon thetopofthecontainer. Thiscycleinvolvestheabsorptionofheathfrom theairinthe refrigeratorcompartmentandthereasoniscooled.Theheatproduced isthendissipatedtotheoutsideenvironmentbyacondenserunit locatedonthetopoftherefrigerator. 5 5.Controlunit Therefrigeratoriscommandfrom a"digitalcontrolunit"anda"main switchpilotlight"inthetoppaneloftherefrigerator. The"mainswitchpilotlight"isforturningonthepowersupply. Thegreenpilotlightcomesontoindicatethattheunitisconnected tothemainelectricityandtostartwork. Thegreenpilotlightcomesofftoindicatethattheunitisdisconnected anddon'twork.The"digitalcontrolunit"isfortheregulationofall parameterstoprovidethecorrectworkingoftherefrigerator.Please consultallparametersintheattachmentmanualofthe"digitalcontrol unit". Thismanualispartoftheinstructionmanualandisveryimportantin caseofservice. 6.Handling TherefrigeratorarriveinPETfilm andpackedincardboardboxona wood pallet. Therefrigeratormustbetransportedandhandledwithcareto avoid posing a hazard to persons or property. Neverplacearefrigeratorwithanin-built refrigeratedunitonitssideorturnitupside downasthismaydamageorimpairoperationoftherefrigeratedunit. Wecannotheldliableforanydamageordefectsarisingdirectlyor indirectlyfrom improperhandlingoftheequipmentornon-compliance with the safeguards illustrated above. 6 7.Installationprocedure Placetherefrigeratorinthecoolestand bestventilatedpartoftheroom.Don'tinstall therefrigeratorinthenearofheatanddirect sunlightsources. Removethestrapssecuringthecardboardpacking Removethecardboard.Covering Remove the PET protection film Cleantherefrigeratorwithmilddetergent andthendryitwithasoftcloth. 8.Connectingtothemainpowersupply Thisoperationmustbecarriedoutby professionally and qualified persons. Therefrigeratoraresuppliedcompletewitha powersupplycablefortheconnectiontothe mainpowersupply.Athermomagneticcircuit breaker(notsupplied)mustbeinstalled betweenthemainspowerpointandthepower supplycableoftherefrigerator. Beforeproceedingmakesurethat: themainsvoltagecorrespondstothevoltageon therefrigerator115V/60Hz/1Ph;toensure properoperationitisessentialforthe powersupplyvoltagetocomewithina 115V rangeof+/-160% oftheunit'sratedvoltage 7 theelectricsystem towhichtherefrigeratorissizedtocaterforthe ratedelectricoutputofthebuffetunitbeinginstalled theelectronicsystem towhichtherefrigeratorisconnectedismade incompliancewithcurrentstandardrequirements theelectricconnectionsandtheinstallationofthethermomagnetic circuitbreakerhavebeendonebyqualifiedperson. Connecting steps: Installathermomagneticcircuitbreakersuitedtotheratedoutputof theunitbeinginstalled Connecttherefrigeratorunittothethermomagneticcircuitbreaker outlet Checkthattherefrigeratorisinorderasdemonstratedbythepilot lightincorporatedinthemainswitchcomingon 9.Maintenanceinstructions Thesmoothoperationandlifeoftheequipmentaremainlydetermined bycorrectandregularmaintenance Cleaning: Regularcleaningoftherefrigeratorunitisstronglyrecommended eachmonth.Pleasefollowtheinstructionsbelow. Disconnecttherefrigeratorpowersupplycablefrom the mainspriortocarryingoutanytypeofcleaningoperation. Cleaningtherefrigeratorsurface: Cleantherefrigeratorwithmilddetergent andthendryitwithasoftcloth. Donotuseabrasivedetergents! 8 Cleaningtheinsideoftherefrigerator Cleantheinsideareamin.eachmonthwithadetergentsuitablefor use with foodstuffs. Cleaning the condenser Foranefficientoperationoftherefrigerator itisadvisabletocleanthecondenser regularlyapprox.every4monthswitha drybrushorvacuum cleaner. 10.Troubleshooting Refrigeratorstopsworking(lightoff): Powersupplyfailure Remedies: Checkthattheplugisinsertedproperlyinthesocket Checkthattheswitchon/off Checkthatthemainsvoltagepowerstheplug Refrigeratortemperaturegoup: Unittoneartoaheatsource Condenserdirtyorclose Remedies: Movethecounterortheheatsourcefurtheraway Cleanthecondenser 11.Technicalservice Fortechnicalservicepleasecontactthedealertechnicaldepartment andgivehim theserialnN°o,.a, nad ndththeeddaateteooffbbuuyy.. 9 12.ConfigurationSketchMap TopMount Reach-Ins Bottom MountReach-Ins 1. Powerswitch 4. Evaporator 7. Condenser 10.Lamp 22.. Microcomputercontroller 5. Evaporatorfanmotor 8. Draincase 11. CASTER 3.Compressor 66.. Condenserfanmotor 9.Shelf Operating Instruction 1.Newuprightair-coolingrefrigeratorshouldbe openedandventilateitbeforeitisinuse.After that,usersshouldusewarm watercleanitsinside. 2.Afterconnectingthepowersupply,pressthe "POWER"switchonthecontrollerkeyboard(GreenIndicatorLightON), thefridgewillcometowork.Themicrocomputercontroller,installedin thecontrollerkeyboard,couldautomaticallyadjustthetemperature ranges.Thisintelligentdigitalcontrollerworksas:ifthetemperature increasesandreachessetpointplusdifferentialthecompressoris startedandthenturnedoffwhenthetemperaturereachesthesetpoint value again. 10 3.MicrocomputerControllerOperationInstruction: 4.Microcomputerpanelsketchmap, meaningsofrunningindicatorlight and LED showing. 5. Todisplaytargetsetpoint,in programmingmodeitselectsaparameter (Mod.XR06CX) orconfirm anoperation. Tostartamanualdefrost Inprogrammingmodeitbrowsestheparametercodesor increases the displayed value . Inprogrammingmodeitbrowsestheparametercodesor decreases the displayed value . Tolockorunlockthekeyboard Toenterinprogrammingmode Toreturntoroom temperature display . 6.Howtoseethepoint. PushandimmediatelyreleasetheSETkey,thesetpointwillbeshowed; PushandimmediatelyreleasetheSETkeyorwaitabout5storeturn tonormalvisualisation. 7.Howtochangethesetpoint. PushtheSETkeyformorethan2secondstochangetheSetpointvalue; Thevalueofthesetpointwillbedisplayedandthe"°C"or"°F"LEDstarts blinking; TochangetheSetvaluepushthe or arrows. TomemorisethenewsetpointvaluepushtheSETkeyagainorwait10s. 8.Howtostartamanualdefrost. PushtheDEF keyformorethan2secondsandamanualdefrost willstart. 11 9.Howtochangeaparametervalue Tochangetheparameter'svalueoperateasfollows: EntertheProgrammingmodebypressingthe keys for 3s ("°C"or"°F"LEDstartsblinking). Selecttherequiredparameter.Pressthe"SET"keytodisplayitsvalue Use or tochangeitsvalue. Press"SET"tostorethenewvalueandmovetothefollowingparameter. Toexit:Press orwait15swithoutpressingakey. NOTE:thesetvalueisstoredevenwhentheprocedureisexitedby waitingthetime-outtoexpire. 10.Tolockthekeyboard. Keeppressedformorethan3sthe keys. The"OF"messagewillbedisplayedandthekeyboardwillbelocked. Ifakeyispressedmorethan3sthe"OF"messagewillbedisplayed. 11.Tounlockthekeyboard. Keeppressedtogetherformorethan3sthe keystillthe"on" messagewillbedisplayed. 12.Alarm signalling. 12 Tableoffunctionsactivatedbythebuttons Tab.2 13 Alam buzzer and LED code alarm relay E0 active ON E1 inactive ON dr active ON LO active ON HI active ON EE inactive ON EF inactive ON Ed inactive ON dF inactive ON Description probe 1 error=control probe 2 error=defrost open door alarm Parametri coninvolti [d0=0/1] [A4=6][+A7] low temperature alarm [AL][Ad] high temperature alarm [Ah][Ad] unit parameter error - operating parameter error - defrost ended by timeout [dP][dt][d4][A8] defrost running [d6=0] 14 Ourproductshavebeenmodifiedpreciselybeforeleaving factory,sotoavoiddamagingcompressorunitorother malfunctions,usersmustn'tmodifythemicrocomputer parametersprivately. OFFICIAL APPROVAL AND RULES CONFORMS TO UL STD.471 CERTIFIED TO CSA STD.C22.2 NO.120 CONFORMSTONSF/ANSISTD.7 15 TechnicalParameters Bottom Mount Reach-Ins Product Description Model code Power source (V) Rating frequency(Hz) Inpurt power(w) Rated current(A) Temperature range () Refrigerant Amount(oz) Dimension (in) Volume (cu.ft) Single-door freezer Two-door freezer Three-door freezer Single-door refrigerator Two-door refrigerator Three-door refrigerator BERB1F BERB2F BERB3F BERB1R BERB2R BERB3R 115 115 115/ 208-230 115 115 115 60 610 6.3 60 935 8.6 60 1360 6.2 60 250 2.1 60 370 3.2 60 470 4.2 -8~-1 R290 4.2 -8~-1 R290 54.5 -8~-1 R290 5.3 +33~+45 R290 3.9 +33~+45 R290 4.9 +33~+45 R290 5.3 27×31.5×84 54.5×31.5×84 81.85×31.5×84 27×31.5×84 54.5×31.5×84 81.85×31.5×84 19.1 44.77 67.99 19.1 44.7 67.99 NOTES :If the technical data has any changes, we will not notify you any longer. 16 Top Mount Reach-Ins Product Description Model code Power source (V) Rating frequency(Hz) Inpurt power(w) Rated current(A) Temperature range () Refrigerant Amount(oz) Dimension (in) Volume (cu.ft) Single-door freezer Two-door freezer Three-door freezer Single-door refrigerator Two-door refrigerator Three-door refrigerator BERT1F BERT2F BERT3F BERT1R BERT2R BERT3R 115 60 610 6.3 -8~-1 R290 4.2 115 60 935 8.6 -8~-1 R290 5.3 115/ 60 1360 6.2 208-230 -8~-1 R290 5.3 115 60 250 2.1 +33~+45 R290 3.9 115 60 370 3.2 +33~+45 R290 4.9 115 60 470 4 .2 +33~+45 R290 5.3 28.7×33.3×81.3 21.4 51.7×33.3×81.3 43.16 77.8×33.3×81.3 64.88 28.7×33.3×81.3 21.4 51.7×33.3×81.3 43.16 77.8×33.3×81.3 64.88 NOTES :If the technical data has any changes, we will not notify you any longer. 17 ATTENTION Onlyfortopmountseries The cabinet is designed to run within specific ambient temperature and humidity levels. These are set out in the climate class system. These levels are never to be exceeded. The climate class for this product can be found on the product description label. Climate Class Ambient Temperatures and Humidity 4 +30°C with 55% RH 5 +40°C with 40% RH In case of water overflow from the re-evaporation tray on the back of an upright cabinet the user must connect a drain hose (Inner diameter 10 mm) to the tray. The hose shall lead to a sewer or a water pan. The user can connect the drainage outlet and the drain hose using the elbow in the accessories. The user need to prepare a 10mm inner diameter drainage hose, which is not included in the accessories. PRELIMINARY DEFROST WATER CHECK The upright cabinets are constructed to allow up to 72 door openings per day according to EN16825. If the use of the door is excessive of this level it is necessary to connect the drain pipe(s) to an external drain. 18 R10001000501 version number 20221205Adobe Photoshop for Windows -- Image Conversion Plug-in Adobe Photoshop CS6 (Windows)