User Manual

Berg BERT3R 64.9 cu.ft. 3-Door Top Mount Reach-In Refrigerator 78"W | Restaurant Equippers

PDF preview unavailable. Download the PDF instead.

ber101 ber102 ber103 ber104 ber105 ber106 manual
Content:
1.Preface................................................................2 2.Useoftheequipment..........................................5 3.Technicalfeatures...............................................5 4.Operation............................................................5 5.Controlunit..........................................................6 6.Handling..............................................................6 7.Installation procedure..........................................7 8.Connectingtothemainpowersupply.................7 9.Maintenanceinstructions....................................8
Cleaning............................................................8 Cleaningtherefrigeratorsurface......................8 Cleaningtheinsideoftherefrigerator...............9 Cleaning the condenser....................................9 10.Troubleshooting................................................9 11.Technicalservice..............................................9 12.ConfigurationSketchMap...............................10
Operating Instruction............................................10 OfficialApprovalAndRules.................................15 TechnicalParameters..........................................16 ATTENTION.........................................................18
1

1.Preface Please read instructions before using this appliance.
IMPORTANT SAFETY INSTRUCTION
 Toreducetheriskoffire,electricshock,orinjurytopersonswhen usingyourproduct,basicsafetyprecautionsshouldbefollowed, including the following.
 Thisappliancemustbeproperlyinstalledandlocatedinaccordance withtheInstallationInstructionbeforeitisused.
 Beforetheapplianceispluggedin,ensurethattheratedvoltage correspondstothevoltageoftheelectricalsystem inyourhome.The powerplugshouldhaveitsownindependentsocket.Usingadapters maycauseoverheatingorburning.
 Thisappliancecanbeusedbychildrenagedfrom 8yearsandabove andpersonswithreducedphysical,sensoryormentalcapabilitiesor lackofexperienceandknowledgeiftheyhavebeengivensupervision orinstructionconcerninguseoftheapplianceinasafewayand understand the hazards involved.
 Childrenshallnotplaywiththeappliance.  Cleaningandusermaintenanceshallnotbemadebychildrenwithout
supervision.  Ifthesupplycordisdamaged,itmustbereplacedbythemanufacturer
oritsserviceagentorasimilarlyqualifiedpersoninordertoavoida hazard.  Connecttoproperlygroundedoutletsonly.Avoidtheuseofextension cords.Donotruncordundercarpeting,runnersorthelike.Arrange cordawayfrom trafficareaandwhereitwillnotcreateatrippinghazard.  Alwaysunplugappliancewhennotinuseandbeforecleaning, adjustingormaintainingthismachine.Todisconnectappliance,turn switchoffandremoveplugfrom powersource.
2

 Donotdisconnectbypullingonthecord.Alwaysdisconnectbygrasping and pulling on the plug top.
 Donotpulloutthecordortouchthepowerplugwithwethands.Clean waterordustfrom thepowerplugandinsertitwiththeendsofthepins securely connected.
 Donotuseoutdoors.  Donotsplashwaterontheappliance.Itmaycauseamalfunctionor
electric shock.  Donotdisassemble,repairoraltertheappliance.Itmaycausefireor
abnormaloperations,whichmayleadtoinjury.  Afteryourfridge-freezerisinoperation,donottouchthecoldsurfacesin
thefreezercompartment,particularlywhenhandsaredamporwet.Skin mayadheretotheseextremelycoldsurfaces.  Neverplaceglassproductsinthefreezerbecausetheymaybebroken whentheirinnercontentsarefrozen.  Therefrigerantandinsulationblowinggasusedintheappliancerequire specialdisposalprocedures.Whendisposal,pleaseconsultwithservice agentorasimilarlyqualifiedperson.  Donotstoreexplosivesubstancessuchasaerosolcanswitha flammablepropellantinthisappliance.  WARNING:Keepclearofobstructionallventilationopeningsinthe appliance enclosure or in the structure for building-in.  WARNING:Donotusemechanicaldevicesorothermeanstoaccelerate thedefrostingprocess,otherthanthoserecommendedbythe manufacturer.  WARNING:Donotdamagetherefrigerantcircuit.  WARNING:Donotuseelectricalappliancesinsidethefoodstorage compartmentsoftheappliance,unlesstheyareofthetyperecommended bythemanufacturer.
3

Warning:Riskoffire/flammablematerials
CAUTION:RISK OFFIREAND EXPLOSION WITH FLAMMABLE REFRIGERANT R290.
 Ifyouneedtheelectronicversioninstructionmanual,pleaseaskthe manufactureroritsserviceagent.
 Max.Loadofshelfis80Kg. Thisinstructionmanualprovidesallthenecessaryinformationregarding:  useoftherefrigerator  technicalspecifications  installationandhandling  operatorproceduresandinstructions  maintenanceoperation Themanualistobeconsideredanintegralpartoftherefrigeratorand shouldbestoredinasafeplaceforfatherconsulttopermitagood workinglifeoftherefrigerator. Theapplianceisintendedforcommercialuseonly. Componentpartsshallbereplacedwithlikecomponentsandthat servicingshallbedonebyfactoryauthorizedservicepersonnel. Themanufacturercannotbeheldliableinthefollowing cases:  improperinstallation(notinaccordancewiththeguidelinesindicated
herein) misuseoftherefrigerator powersupplydefects improperorinadequatemaintenance unauthorisedmodificationortampering useofnon-originalspareparts partialortotalfailuretocomplywiththeinstructions
Allelectricalequipmentcanbehazardoustohealth.Currentstandards andlegalrequirementsmustbecompliedwithduringtheinstallationand useofanyequipment.
4

2.Useoftheequipment This fridge/freezer is designed for cooling/freezing fresh perishable foodstuffs in restaurants, canteens and similar catering establishments. Do not utilise the equipment to store medical supplies. The optimum operational ambient temperatures are between +10~ +40.
3.Technicalfeatures Therefrigeratorisaventilatedsystem,theevaporatorisinaseparate insulatedboxonthetop.Allthematerialsusedinthemanufactureof thisunitareguaranteedtobesuitableforusewithfoodstuffs.The gasesusedinproducesisR290.Therefrigeratingcircuitareincompliance withthecurrentnormative.
4.Operation Thegasintherefrigeratingcircuitisinthefirsttimecompressed, liquefiedandthenevaporatedintheventilatedevaporator,situatedon thetopofthecontainer. Thiscycleinvolvestheabsorptionofheathfrom theairinthe refrigeratorcompartmentandthereasoniscooled.Theheatproduced isthendissipatedtotheoutsideenvironmentbyacondenserunit locatedonthetopoftherefrigerator.
5

5.Controlunit Therefrigeratoriscommandfrom a"digitalcontrolunit"anda"main switchpilotlight"inthetoppaneloftherefrigerator. The"mainswitchpilotlight"isforturningonthepowersupply. Thegreenpilotlightcomesontoindicatethattheunitisconnected tothemainelectricityandtostartwork. Thegreenpilotlightcomesofftoindicatethattheunitisdisconnected anddon'twork.The"digitalcontrolunit"isfortheregulationofall parameterstoprovidethecorrectworkingoftherefrigerator.Please consultallparametersintheattachmentmanualofthe"digitalcontrol unit". Thismanualispartoftheinstructionmanualandisveryimportantin caseofservice.
6.Handling TherefrigeratorarriveinPETfilm andpackedincardboardboxona wood pallet.
Therefrigeratormustbetransportedandhandledwithcareto avoid posing a hazard to persons or property. Neverplacearefrigeratorwithanin-built refrigeratedunitonitssideorturnitupside downasthismaydamageorimpairoperationoftherefrigeratedunit. Wecannotheldliableforanydamageordefectsarisingdirectlyor indirectlyfrom improperhandlingoftheequipmentornon-compliance with the safeguards illustrated above.
6

7.Installationprocedure  Placetherefrigeratorinthecoolestand bestventilatedpartoftheroom.Don'tinstall therefrigeratorinthenearofheatanddirect sunlightsources.
Removethestrapssecuringthecardboardpacking Removethecardboard.Covering Remove the PET protection film
Cleantherefrigeratorwithmilddetergent andthendryitwithasoftcloth.

8.Connectingtothemainpowersupply
Thisoperationmustbecarriedoutby professionally and qualified persons.
Therefrigeratoraresuppliedcompletewitha powersupplycablefortheconnectiontothe mainpowersupply.Athermomagneticcircuit breaker(notsupplied)mustbeinstalled betweenthemainspowerpointandthepower supplycableoftherefrigerator.

Beforeproceedingmakesurethat:

 themainsvoltagecorrespondstothevoltageon

therefrigerator115V/60Hz/1Ph;toensure

properoperationitisessentialforthe powersupplyvoltagetocomewithina

115V

rangeof+/-160% oftheunit'sratedvoltage

7

 theelectricsystem towhichtherefrigeratorissizedtocaterforthe ratedelectricoutputofthebuffetunitbeinginstalled
 theelectronicsystem towhichtherefrigeratorisconnectedismade incompliancewithcurrentstandardrequirements
 theelectricconnectionsandtheinstallationofthethermomagnetic circuitbreakerhavebeendonebyqualifiedperson.
Connecting steps:  Installathermomagneticcircuitbreakersuitedtotheratedoutputof
theunitbeinginstalled  Connecttherefrigeratorunittothethermomagneticcircuitbreaker
outlet  Checkthattherefrigeratorisinorderasdemonstratedbythepilot
lightincorporatedinthemainswitchcomingon
9.Maintenanceinstructions Thesmoothoperationandlifeoftheequipmentaremainlydetermined bycorrectandregularmaintenance Cleaning: Regularcleaningoftherefrigeratorunitisstronglyrecommended eachmonth.Pleasefollowtheinstructionsbelow. Disconnecttherefrigeratorpowersupplycablefrom the mainspriortocarryingoutanytypeofcleaningoperation. Cleaningtherefrigeratorsurface: Cleantherefrigeratorwithmilddetergent andthendryitwithasoftcloth. Donotuseabrasivedetergents!
8

Cleaningtheinsideoftherefrigerator Cleantheinsideareamin.eachmonthwithadetergentsuitablefor use with foodstuffs.
Cleaning the condenser Foranefficientoperationoftherefrigerator itisadvisabletocleanthecondenser regularlyapprox.every4monthswitha drybrushorvacuum cleaner.
10.Troubleshooting Refrigeratorstopsworking(lightoff):  Powersupplyfailure  Remedies:  Checkthattheplugisinsertedproperlyinthesocket  Checkthattheswitchon/off  Checkthatthemainsvoltagepowerstheplug Refrigeratortemperaturegoup:  Unittoneartoaheatsource  Condenserdirtyorclose  Remedies:  Movethecounterortheheatsourcefurtheraway  Cleanthecondenser
11.Technicalservice Fortechnicalservicepleasecontactthedealertechnicaldepartment andgivehim theserialnN°o,.a, nad ndththeeddaateteooffbbuuyy..
9

12.ConfigurationSketchMap
TopMount Reach-Ins

Bottom MountReach-Ins

1. Powerswitch 4. Evaporator 7. Condenser 10.Lamp

22.. Microcomputercontroller 5. Evaporatorfanmotor 8. Draincase 11. CASTER

3.Compressor 66.. Condenserfanmotor 9.Shelf

Operating Instruction

1.Newuprightair-coolingrefrigeratorshouldbe openedandventilateitbeforeitisinuse.After that,usersshouldusewarm watercleanitsinside.
2.Afterconnectingthepowersupply,pressthe "POWER"switchonthecontrollerkeyboard(GreenIndicatorLightON), thefridgewillcometowork.Themicrocomputercontroller,installedin thecontrollerkeyboard,couldautomaticallyadjustthetemperature ranges.Thisintelligentdigitalcontrollerworksas:ifthetemperature increasesandreachessetpointplusdifferentialthecompressoris startedandthenturnedoffwhenthetemperaturereachesthesetpoint value again.
10

3.MicrocomputerControllerOperationInstruction:

4.Microcomputerpanelsketchmap,

meaningsofrunningindicatorlight

and LED showing.

5.

Todisplaytargetsetpoint,in

programmingmodeitselectsaparameter

(Mod.XR06CX)

orconfirm anoperation.

 Tostartamanualdefrost

 Inprogrammingmodeitbrowsestheparametercodesor

increases the displayed value .

Inprogrammingmodeitbrowsestheparametercodesor

decreases the displayed value .

Tolockorunlockthekeyboard

Toenterinprogrammingmode

Toreturntoroom temperature

display .

6.Howtoseethepoint.

PushandimmediatelyreleasetheSETkey,thesetpointwillbeshowed;

PushandimmediatelyreleasetheSETkeyorwaitabout5storeturn

tonormalvisualisation.

7.Howtochangethesetpoint.

PushtheSETkeyformorethan2secondstochangetheSetpointvalue;

Thevalueofthesetpointwillbedisplayedandthe"°C"or"°F"LEDstarts

blinking;

TochangetheSetvaluepushthe or arrows.

TomemorisethenewsetpointvaluepushtheSETkeyagainorwait10s.

8.Howtostartamanualdefrost.

PushtheDEF keyformorethan2secondsandamanualdefrost

willstart.

11

9.Howtochangeaparametervalue

Tochangetheparameter'svalueoperateasfollows:

EntertheProgrammingmodebypressingthe

keys for 3s

("°C"or"°F"LEDstartsblinking).

Selecttherequiredparameter.Pressthe"SET"keytodisplayitsvalue

Use or tochangeitsvalue.

Press"SET"tostorethenewvalueandmovetothefollowingparameter.

Toexit:Press

orwait15swithoutpressingakey.

NOTE:thesetvalueisstoredevenwhentheprocedureisexitedby

waitingthetime-outtoexpire.

10.Tolockthekeyboard.

Keeppressedformorethan3sthe

keys.

The"OF"messagewillbedisplayedandthekeyboardwillbelocked.

Ifakeyispressedmorethan3sthe"OF"messagewillbedisplayed.

11.Tounlockthekeyboard.

Keeppressedtogetherformorethan3sthe

keystillthe"on"

messagewillbedisplayed.

12.Alarm signalling.

12

Tableoffunctionsactivatedbythebuttons Tab.2 13

Alam buzzer and LED

code alarm relay

E0 active

ON

E1 inactive

ON

dr

active

ON

LO active

ON

HI

active

ON

EE

inactive

ON

EF

inactive

ON

Ed

inactive

ON

dF

inactive

ON

Description
probe 1 error=control probe 2 error=defrost open door alarm

Parametri coninvolti [d0=0/1]
[A4=6][+A7]

low temperature alarm

[AL][Ad]

high temperature alarm [Ah][Ad]

unit parameter error

-

operating parameter error -

defrost ended by timeout [dP][dt][d4][A8]

defrost running

[d6=0]

14

Ourproductshavebeenmodifiedpreciselybeforeleaving factory,sotoavoiddamagingcompressorunitorother malfunctions,usersmustn'tmodifythemicrocomputer parametersprivately.
OFFICIAL APPROVAL AND RULES
CONFORMS TO UL STD.471 CERTIFIED TO CSA STD.C22.2 NO.120 CONFORMSTONSF/ANSISTD.7
15

TechnicalParameters
Bottom Mount Reach-Ins

Product Description Model code Power source (V) Rating frequency(Hz) Inpurt power(w) Rated current(A) Temperature range () Refrigerant Amount(oz) Dimension (in) Volume (cu.ft)

Single-door freezer Two-door freezer Three-door freezer Single-door refrigerator Two-door refrigerator Three-door refrigerator

BERB1F BERB2F BERB3F BERB1R BERB2R BERB3R

115
115 115/ 208-230 115
115
115

60 610 6.3 60 935 8.6 60 1360 6.2 60 250 2.1 60 370 3.2 60 470 4.2

-8~-1 R290 4.2 -8~-1 R290 54.5 -8~-1 R290 5.3 +33~+45 R290 3.9 +33~+45 R290 4.9 +33~+45 R290 5.3

27×31.5×84 54.5×31.5×84 81.85×31.5×84 27×31.5×84 54.5×31.5×84 81.85×31.5×84

19.1 44.77 67.99 19.1 44.7 67.99

NOTES :If the technical data has any changes, we will not notify you any longer.

16

Top Mount Reach-Ins

Product Description Model code Power source (V) Rating frequency(Hz) Inpurt power(w) Rated current(A) Temperature range () Refrigerant Amount(oz) Dimension (in) Volume (cu.ft)

Single-door freezer Two-door freezer Three-door freezer Single-door refrigerator Two-door refrigerator Three-door refrigerator

BERT1F BERT2F BERT3F BERT1R BERT2R BERT3R

115 60 610 6.3 -8~-1 R290 4.2

115 60 935 8.6 -8~-1 R290 5.3

115/ 60 1360 6.2
208-230

-8~-1

R290 5.3

115 60 250 2.1 +33~+45 R290 3.9

115 60 370 3.2 +33~+45 R290 4.9

115 60 470 4 .2 +33~+45 R290 5.3

28.7×33.3×81.3 21.4 51.7×33.3×81.3 43.16 77.8×33.3×81.3 64.88 28.7×33.3×81.3 21.4 51.7×33.3×81.3 43.16 77.8×33.3×81.3 64.88

NOTES :If the technical data has any changes, we will not notify you any longer.

17

ATTENTION Onlyfortopmountseries

The cabinet is designed to run within specific ambient temperature and humidity levels. These are set out in the climate class system. These levels are never to be exceeded. The climate class for this product can be found on the product description label.

Climate Class

Ambient Temperatures and Humidity

4

+30°C with 55% RH

5

+40°C with 40% RH

In case of water overflow from the re-evaporation tray on the back of an upright cabinet the user must connect a drain hose (Inner diameter 10 mm) to the tray. The hose shall lead to a sewer or a water pan. The user can connect the drainage outlet and the drain hose using the elbow in the accessories. The user need to prepare a 10mm inner diameter drainage hose, which is not included in the accessories.

PRELIMINARY DEFROST WATER CHECK

The upright cabinets are constructed to allow up to 72 door openings per day according to EN16825. If the use of the door is excessive of this level it is necessary to connect the drain pipe(s) to an external drain.

18

R10001000501 version number 20221205


Adobe Photoshop for Windows -- Image Conversion Plug-in Adobe Photoshop CS6 (Windows)