tiastar LV MCC identification guide CAT

low-voltage motor control centers, LV MCC, aftermarket, renewal parts, splice kits, drip shield, structural , auxiliary handle, door assembly, door parts, mechanism, fuse kits, control part, terminal blocks, nameplate kits, overload reset kits, shutter mechanism, identification

Motor Control Centers (MCC) Identification Guide - Siemens

Siemens Model 95 Product Description The Model 95 retrofit units are designed to fit into Model 95 MCCs. This upgrade from Model 95 included changes in handles, color, pilot devices, and

Brochure - tiastar MCC ABS certified for marine, offshore, and energy applications

Smart motor control centers | Low-voltage motor control centers | Siemens USA

PDF preview unavailable. Download the PDF instead.

ansi-lv-mcc-ccbr-mccar-0813-print-low
Motor Control Centers (MCC) Identification Guide
www.usa.siemens.com/mccaftermarket
Answers for industry.

Table of Contents

Overview

MCC Timeline

1

MCC Quick Identification Table

2

MCC Number Overview

3

Identification by Handle Type

4

Identification by Unit Stab

5

Siemens MCC Models

tiastar

6

Model 95+

7

Model 95

8

Model 90

9

Marq21

10

Furnas MCC Models

System89

11

Class89

12

Allis-Chalmers Models

Mark 2

13

Mark 1

14

ITE Models

Gould 5600

15

Gould 9600

16

Request for Quote

17

MCC Timeline

Siemens has an installed base of Motor Control Centers dating back to 1964 due to acquisitions of Allis-Chalmers in 1978, ITE Gould in 1983 and Furnas Electric in 1996. This has resulted in eleven MCC models installed across the United States. Replacement units for these models as well as the current tiastarTM MCC offerings are built in the Siemens West Chicago plant. Siemens developed this tool to help people gain a better understanding of the wide variety of this installed base of MCCs. This should enable

people to order aftermarket buckets or new MCCs much easier. In this brochure, all the tools necessary for identifying existing MCCs are included. All items listed as follows: timeline, product overview, identification guide and product descriptions. The intent of this guide is to provide a tool for Siemens customers so they can make a more educated purchasing decision. If you have any questions, please contact your local Siemens representative.

MCC Type ITE Gould 9600 ITE

MCC Timeline

Allis-Chalmers Mark 1

Allis-Chalmers

Furnas Class 89

Furnas

ITE Gould 5600 Allis-Chalmers Mark2 Siemens-Allis Marq21

ITE
AllisChalmers
Siemens-Allis Siemens

Furnas System89

Furnas

Siemens-Furnas

Siemens Model 90

Siemens

Siemens Model 95

Siemens

Siemens Model 95+

Siemens

Siemens tiastar

Siemens

1964 1965 1971 1972 1975 1979 1980 1986 1990 1992 1993 1995 1996 1997 2001 2002 >2002

Year

Note: Timeline represents approximate values

1

MCC Quick Identification Table
This overview is a clear and concise snap shot of Siemens entire MCC product offering. For your convenience, typical MCC part numbers are shown for continued identification possibilities. Furthermore, the overview covers the standard options for the product offering.

Original Manufacturer

Model

Siemens

tiastarTM

Siemens

Model 95 +

Siemens Siemens Siemens-Allis Siemens/Furnas

Model 95 Model 90 Marq21 System89

Furnas

Class89

Allis-Chalmers Allis-Chalmers ITE ITE

Mark 2 Mark 1 Gould 5600 Gould 9600

Production Dates 2002 ­ Current
1997 ­ 2001 1995 ­ 1997

Type of Handle Mechanism Lever
Slider Slider

Typical MCC Serial Number 89BF#####-###
89BS#####-### 89BB#####-### W#### 95BF#####-### 95BS#####-### 95BB#####-### ####
09-001-####-#####-###

1990 ­ 1997

Slider

30-001-####-#####

1975 ­ 1990

Slider

01-14##-#####-##

1980 ­ 2001

Lever

1965 ­ 1979

Lever

1972 ­ 1975

Rotary

Same as Siemens tiastar
89FV####-### 89SV####-### 89BV####-### V####
#####

1965 ­ 1972

Slider

#####

1971 ­ 1992 1964 ­ 1971

Rotary Rotary

84-##### 85-##### 86-#####

Page Number
6
7
8 9 10 11
12
13 14 15 16

2

Style (Serial)/Order Number Overview
This visual guide will help you locate and identify your MCC by its order number or style number. Please note your unit's style or order number and report this when placing your order. This will help ensure the accuracy and timely completion of your request.
Style (Serial) Number
The style number can be found on the name plate of your MCC. This is generally located on the section of incoming power supply.
Order Number
The order number is an acceptable alternative to the style number. This can be found on the inside of a specific bucket. Please also report the unit number when possible (located below the order number). Note: Some older models may not have this sticker.
3

Identification by Handle Type

tiastar (page 6) System89 (page 11)

Model 95+ (page 7) Model 95 (page 8) Model 90 (page 9) Marq21 (page 10)

Class89 (page 12)

Marq21 (page 10) Mark 2 (page 13)

Mark 1 (page 14)

Gould 5600 (page 15)

Gould 5600 (page 15)
4

Gould 9600 (page 16)

Identification by Unit Stab

tiastar (page 6) Model 95+ (page 7) System89 (page 11)

Model 95+ (page 7) System89 (page 11)

Model 95 (page 8) Model 90 (page 9) Marq21 (page 10)

Class89 (page 12)

Marq21 (page 10) Mark 2 (page 13)

Mark 1 (page 14)

Gould 5600 (page 15)

Gould 9600 (page 16)
5

Siemens tiastarTM
Product Description
Introduced in 2002, Siemens tiastar Motor Control Center represents a rugged time proven design. Unit widths are normally 15" or 20" wide, and 12" tall with 6" increments.

Label Identification

Timeline: Original Mfg: MCC#:

2002 ­ Current Siemens 89BF#####-### 89BS#####-### 89BB#####-###

6

Siemens Model 95+
Product Description
The Model 95+ retrofit units are designed to fit into Model 95+ MCCs. This upgrade from Model 95 included changes in handles, color, pilot devices, and stabs. Unit widths are normally 15" or 20" wide, and 12" tall with 6" increments. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up.

Label Identification

Timeline: Original Mfg: MCC#:

1997 ­ 2001 Siemens 95BF#####-### 95BS#####-### 95BB#####-###

7

Siemens Model 95
Product Description
Model 95 served as a style template for many old MCC units since installation procedures and dimensions stayed the same. Unit widths are normally 15" or 20" wide, and 12" tall with 6" increments. The original Model came with a variety of CB and starters from ITE, C-H and Siemens 3TF & 3UA Overload. Today, we provide you with Siemens breakers and starters. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up.

Label Identification
8

Timeline: Original Mfg: MCC#:

1995 ­ 1997 Siemens 09-001-####-#####-###

400A feeder in a plug-in unit requires 30" (height). If an order is placed for a 400A feeder in a 24" (height) unit, the unit will be fixed mounted 20" wide and will need to be wired to the horizontal bus.

Siemens Model 90
Product Description
The Model 90 retrofit units are designed to fit into Model 90 MCCs. Unit widths are normally 15" or 20" wide, and 12" tall with 6" increments. The original Model 90 came with a variety of CB and starters from ITE, C-H, and Siemens 3TF and 3UA Overload. Today, we provide you with Siemens breakers and starters. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up.

Label Identification

Timeline: Original Mfg: MCC#:

1995 ­ 1997 Siemens 30-001-####-#####

9

Siemens-Allis Marq21

Label Identification

Product Description
The Marq21 retrofit units are designed to fit into Marq21 MCCs. Marq21 was created from the forge of two of the world's foremost electrical companies, Siemens-Allis. Units widths are normally 15" or 20" wide, and 12" tall with 6" increments. Original components are no longer available. Today, we provide you with Siemens breakers and starters.
Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up.

Timeline: Original Mfg: MCC#:

1975 ­ 1990 Siemens-Allis 01-14##-#####-##

Important Note: Models produced between 1982­1985 may feature a vertical bus phase isolation barrier. The Model 95 style retrofit buckets cannot be used due to interference with the bucket stabs. The unit will instead be supplied as a panelmounted unit that is cabled to the horizontal bus (cables are provided).
The aftermarket units cannot be installed in the top location of the existing MCC structure.
10

Furnas System89
Product Description
This is an upgrade from Class89 developed by Furnas in 1965. Unit structures are normally 15" or 20" wide, and 12" tall with 6" increments. The original System89 came with a variety of CB and starters from Westinghouse, GE and Furnas Electric. Today, we provide you with Siemens breakers and starters. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up.

Label Identification

Timeline: Original Mfg: MCC#:

1979 ­ 2001 Furnas Electric 89BF#####-### 89BS#####-### 89BB#####-###

11

Furnas Class89
Product Description
Original components are no longer available. Replacement units are no longer available. A new tiastar MCC can be cabled to an existing line up with an MLO assembly.

Label Identification

Timeline: Original Mfg: MCC#:

1965 ­ 1979 Furnas Electric 89FVXX###-### 89SVXX###-### 89BVXX###-###

12

Allis-Chalmers Mark 2
Product Description
The Mark 2 retrofit units are designed to fit into their old design. This is an upgrade from the Mark 1 in ValueLine family. Unit widths are normally 15" or 20" wide, and 12" tall with 6" increments. The original Mark 2 came with a variety of CB and starters from Westinghouse and Allis-Chalmers. Original components are no longer available. Today, we provide you with Siemens breakers and starters. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up.

Important Note: The aftermarket units cannot be installed in the top location of the existing MCC structure.

Timeline: Original Mfg: MCC#:

1972 ­ 1975 Siemens #####

13

Allis-Chalmers Mark 1
Product Description
Original components are no longer available. Replacement units are no longer available. A new tiastar MCC can be cabled to an existing line up with an MLO assembly

Timeline: Original Mfg: MCC#:

1965 ­ 1971 Allis Chambers #####

14

ITE Gould 5600
Product Description
The 5600 MCC retrofit units were designed to fit into their old design. Units are 15" wide and the fix mounted panels are 20" wide. Original components are not longer available. Today we provide you with Siemens starters and breakers. Note: Units can be provided as a fix-mounted unit cabled to the horizontal bus, or as a plug-in unit. Add-on MCCs: A new tiastar MCC can be cabled to an existing line up with an MLO assembly.

Label Identification

Timeline 5600: Original Mfg: MCC#:

1971 ­ 1992 ITE / Rowan Control 84-##### 85-##### 86-#####

15

ITE Gould 9600

Label Identification

Product Description
The 9600 MCC retrofit units were designed to fit into their old design. Units are 20". Original components are no longer available. Today we provide you with Siemens breakers and starters.
Note: Units can be provided only as a fix-mounted unit cabled to the horizontal bus.
Add-on MCCs: Replacement units are not available. A new tiastar MCC can be cabled to an existing line up with an MLO assembly.

Timeline: Original Mfg: MCC#:

1964 ­ 1971 ITE / Rowan Control 84-##### 85-##### 86-#####

16

Request for Quote
To request a quote for aftermarket MCC units, please visit www.usa.siemens.com/mccaftermarket
17

Siemens Industry, Inc. Industry Automation Division 3333 Old Milton Parkway Alpharetta, GA 30005 1-800 -241-4453

Subject to change without prior notice. Order No: CCBR-MCCAR-0813 All rights reserved. Printed in USA ©2013 Siemens Industry, Inc.

info.us@siemens.com

www.usa.siemens.com/mccaftermarket

The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract.
All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.


Adobe PDF Library 9.0 Adobe InDesign CS4 (6.0.6)