User Manual for TSun models including: Talent-MG2-WP, Talent-MG2-GP, Talent-MG2-WP Microinverter Monitor System, Microinverter Monitor System, Monitor System
pro solarmanpv login site id
File Info : application/pdf, 25 Pages, 1.61MB
DocumentDocumentSTORE THE FUTURE User Manual Talent-MG2-WP Talent-MG2-GP TSUNESS Co., Ltd CONTENT Read Me First Warning Contact Talent-MG2 Monitoring System Packing List Product Appearance Technical Data Installation Wi-Fi Configuration (Only Talent-MG2-WP) LED Description Website Configuration Step 1: Install the microinverter and the monitoring device Step 2: Establish an account Step 3: Networking for the monitoring system Step 4: Create a Plant Step 5: Edit the system layout Remote active power control function DRM function Zero export control function Step 1: Confirm the loads' capacity for CT and Meter Step 2: Install the meter and CT Step 3: Connect the meter to the RS485 port of monitor device Step 4: Set zero export function on the monitor platform Talent-MG2-WP/GP 1 1 1 2 2 3 4 5 7 8 9 9 9 10 12 14 15 15 16 16 17 20 21 www.tsun-ess.com Talent-MG2-WP/GP Read Me First Dear customer, thank you for choosing the TSOL-M Series micro inverter from TSUNESS. We hope you will find our products meet your needs for renewable energy. Meantime, we appreciate your feedbacks regarding our products. This manual contains important instructions for Talent-MG2 Monitoring System. For safety, only qualified technician, who has received training or has demonstrated skills can install Talent-MG2 Monitoring System under the guide of this document. Warning Only qualified personnel should install, troubleshoot, or replace the monitoring system. Before installation, check the unit to ensure absence of any transport or handling damage, which could affect insulation integrity or safety clearances. All repairs should be carried out using only qualified spare parts, which must be installed in accordance with their intended use and by a licensed contractor or authorized TSUNESS service representative. Contact If you have technical problems about our products, contact the TSUN Service line. TSUNESS Co., Ltd Tel: +86 512 6618 6018 E-mail:sales@tsun-ess.com | www.tsun-ess.com Add: Building E1, No. 555, Chuangye Road, Dayun Town, Jiashan County, Jiaxing City, Zhejiang Province, China www.tsun-ess.com 1 Talent-MG2 Monitoring System Talent-MG2-WP/GP The Monitor Device is the key component in Talent-MG2 monitoring system. It is the relay station of the monitoring system, which operates between the microinverters and the Monitoring Server. The Monitor Device communicates with the microinverters in the system via 2.4G RF wireless to collect the data and status of the microinverters in the system. At the same time, Monitor Device connects to the Internet through WIFI (Talent-MG2-WP) or GPRS (Talent-MG2-GP), which realizes the information exchange with the monitoring service and sends all the running data of microinverters and status of the system to the monitoring server. It receives the control commands from the monitoring server and sends the data to the microinverters in the system to achieve remote operation and maintenance. Packing List a b c d Object a b c d Description Monitor Device Antenna Adaptor Bracket Quantity 1 2 1 1 2 www.tsun-ess.com Talent-MG2-WP/GP Product Appearance Object A B C D E F* G H Description Power LED Communication LED (Server) Communication LED (Inverter) Alarm LED SD Card Slot SIM Card Slot Antenna (Wi-Fi/GPRS) RS485 Port * Only Talent-MG2-G has a SIM Card Slot. Object I J K L M N O Description DRM Port (For Australia) Ethernet Port USB Port Reset Hole Power Port Antenna (2.4G) Installation Hole 3 www.tsun-ess.com Technical Data Model Communication to Microinverter Signal Maximum Distance(Open Space) Monitoring Data Limit Communication to Server Sample Rate Signal Communication to Meter Signal Maximum Distance (RS485 Cable) Power Supply (Adapter) Type Input Voltage/Frequency Output Voltage/Current Power Consumption Mechanical Data Ambient Temperature(¥) Dimensions (W*H*D mm) Weight (kg) Mounting System Indicator Light Talent-MG2-WP/GP Talent-MG2-WP Talent-MG2-GP 2.4G RF 100m 99 panels Per 15 minutes Wi-Fi (802.11b/g/n) GSM (850/900/1800/1900MHz) RS485 500m External plug-in adapter 100 to 240V AC / 50 or 60Hz 5V DC / 2A 2.5W(typical), 5W(maximum) -20~+55 200*101*29 0.2 Wall mounting / Desktop mounting 4 LED 4 www.tsun-ess.com Talent-MG2-WP/GP Installation 1.Take two antennas out from the box, screw the antenna into the Wi-Fi/GPRS port and 2.4G port. Note: While installing Talent-MG2-GP, there are a GSM antenna and a 2.4G antenna. Do not insert the antenna to the wrong port. Note: While the monitor device is installed inside the metal box or under the metal / concrete roof, extended 2.4G cable or 2.4G sucker antenna will be suggested. 2.Insert the SIM Card into the SIM Card Slot, press the SIM Card in until you heard "Click" (only for Talent-MG2-GP). 3.Screw the bracket on the wall and use at least two screw holes (one from each side) to fix the bracket (the M4 screws need to be prepared by installer). 5 www.tsun-ess.com Talent-MG2-WP/GP 4.Match the bracket's upper buckle with monitor device. Then match the bracket's lower buckle by gently press the lower side of the monitor device until hear the"Click". Note: Make sure the antennas are vertical to the wall. 5.Power on the monitor device. Note: Monitor device could also be put on the table. Make sure the antennas are vertical to the table. 6 www.tsun-ess.com Talent-MG2-WP/GP Wi-Fi Configuration (Only Talent-MG2-WP) 1.Connect the wireless name of MG2-W via computer or mobile phone. 2.Open the browser and enter 10.10.100.254 to open the Wi-Fi configuration page. The username and password are `admin' by default. 3.Click the Wi-Fi parameter menu on the left menu bar to enter the Wi-Fi parameter configuration. 4.Click the search button in the lower right corner, select the Wi-Fi name to be connected to the monitoring device. 5.Enter the password and click Save. 7 www.tsun-ess.com Talent-MG2-WP/GP 6.Click Restart. LED Description LED Mark LED Color LED All LEDs Status Explanation Monitor device power on or power off Network communication Microinverter communication Fault State Description Firmware upgrading www.tsun-ess.com 8 Talent-MG2-WP/GP Starting up Power on Power off Communicating with Server Internet disconnected Internet connected, Server disconnected Communicating with all microinverters Some microinverters disconnected No ID (Please do Networking) Normal Monitor device alarm Microinverter alarm Meter alarm Website Configuration Step 1: Install the microinverter and the monitoring device 1.Install the microinverter system. Please read the Quick Installation Guide or the User Manual of microinverter on www.tsun-ess.com/downloads before installation. 2.Install the monitoring device. Connect the power adapter into the socket 3.Make sure the microinverter system and the monitoring device are working well. Step 2: Establish an account 1.Visit the monitor website pro.solarmanpv.com directly. Or enter this monitor website by the official website of TSUNESS www.tsun-ess.com . 9 www.tsun-ess.com Talent-MG2-WP/GP Click the "Register" button and register a new account. Step 3: Networking for the monitoring system 1.Login to the platform and find the "Network" page by Applications ¹ Network. (Please make sure that the monitoring device has already connected to the server.) 10 www.tsun-ess.com Talent-MG2-WP/GP 2.Click "+Select" to input the SN of monitoring device. 3. Click "Upload Network Relationship" to download the template file. After editing the file, click "Select a File" to upload file. 11 www.tsun-ess.com Talent-MG2-WP/GP Step 4: Create a Plant 1.Find the "Plants" page by Monitor ¹ Plants. Click `Create a Plant' to create a new plant. 2.Input basic information, system information, yield information and owner information in this page. 12 www.tsun-ess.com Talent-MG2-WP/GP 3. Click "Save" and add a monitoring device in this plant. Click "add a New Gateway/Logger" and input the SN of the monitoring device. 4.All the plants can be viewed and managed in "Plants" page. 13 www.tsun-ess.com Talent-MG2-WP/GP Step 5: Edit the system layout 1.Find the "Plants" page by Monitor ¹ Plants ¹ "plant name" . Then enter the "Layout" page and click "Click here to edit system layout". 2.Drag the components to the right side to finish the physical layout. 14 www.tsun-ess.com Talent-MG2-WP/GP Remote active power control function In some countries, it might require that the generating plants should be equipped with a logic interface (input port) in order to cease output active power or limit active power to a regulating level. This logic input can be RS485 port, Ethernet port, etc. Talent-MG2-WP/GP provide RTU Modbus protocol over RS485 port for this remote active power control. For more information, please refer to "Modbus implementation Technical Note". DRM function DRM port is provided to support several demand response modes as below by connecting external control device with a standard RJ-45 connector. For Talent-MG2-WP/GP, it can support DRM0/5/6/7/8 if used with TSUN microinverters. Mode Requirement DRM0 Operate the disconnection device DRM1 Do not consume power DRM2 Do not consume at more than 50% of rated power DRM3 Do not consume at more than 75% of rated power AND Source reactive power if capable DRM4 Increase power consumption (subject to constraints from other active DRMs) DRM5 Do not generate power DRM6 Do not generate at more than 50% of rated power DRM7 Do not generate at more than 75% of rated power AND Sink reactive power if capable DRM8 Increase power generation (subject to constraints from other active DRMs) 15 www.tsun-ess.com Talent-MG2-WP/GP Zero export control function To maintain the safety and quality level of the grid network, some countries' local grid authorities limit the PV generated power exporting to the grid. Zero export function can meet this requirement and help users install a bigger PV system without violating export regulations. Step 1: Confirm the loads' capacity for CT and Meter Make sure the CT/Meter range can cover the maximum loads power or PV system generating power. There are 3 types of CHINT meter and different types of CT that you can choose base on the actual installation requirement. Meter Model Type SN Description DDSU666(60A) Single Phase 10C011XXXXXX Direct connect, NOT via any kind of CT DTSU666(80A) Three Phase 10C013XXXXXX Direct connect, NOT via any kind of CT DTSU666(5A) Three Phase 10C012XXXXXX Compatible with 100A/5A, 300A/5A, and 600A/5A CT Grid Type Single Phase System (230V) Three Phase System (230V/400V) Split Phase System (120V/240V) Three Phase System (120V/208V) Meter Model DDSU666(60A) DTSU666 (100A/5A,300A/5A, 600A/5A), DTSU666 (80A) Note: There are several versions of CHINT meters in the market. The protocol in the meter is customermized for different inverter manufacturers. Please buy the CHINT meters from TSUN to ensure the usage of Zero Export Function. 16 www.tsun-ess.com Step 2: Install the meter and CT CHINT DDSU666 Single Phase Meter (Direct connect) Talent-MG2-WP/GP Port 1 Port 2 Port 3 Port 4 Port 24 Port 25 input port, connect to the L line; output port, connect to the L line; connect to the N line; connect to the N line; connect to the A port of RS485 port connect to the B port of RS485 port 17 www.tsun-ess.com Talent-MG2-WP/GP CHINT DTSU666 Three Phase Meter (Direct connect) Port 1 Port 3 Port 4 Port 6 Port 7 Port 9 Port 10 Port 24 Port 25 input port, connect to the L line of phase A; output port, connect to the L line of phase A; input port, connect to the L line of phase B; output port, connect to the L line of phase B; input port, connect to the L line of phase C; output port, connect to the L line of phase C; connect to the N line; connect to the A port of RS485 port connect to the B port of RS485 port 18 www.tsun-ess.com CHINT DTSU666 Three Phase Meter (Via CT) Talent-MG2-WP/GP Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 Port 9 Port 10 Port 24 Port 25 connect to the red wire of CT in Phase A; connect to the L line of phase A; connect to the black wire of CT in Phase A; connect to the red wire of CT in Phase B; connect to the L line of phase B; connect to the black wire of CT in Phase B; connect to the red wire of CT in Phase C; connect to the L line of phase C; connect to the black wire of CT in Phase C; connect to the N line; connect to the A port of RS485 port connect to the B port of RS485 port Make sure the CT (Current Transformer) has been installed in the right direction, otherwise will affect the current readings and Meter function. Meter install on the Load side, the CT arrow pointed to the Loads. 19 www.tsun-ess.com Talent-MG2-WP/GP Step 3: Connect the meter to the RS485 port of monitor device The picture below indicates the RS485 A Port and B Port on the monitor device. When the RS485 cable length is more than 200m, use the shorting jumper on the first two ports from the RS485 port. For CHINT Single Phase Meter: For CHINT Three Phase Meter: 20 www.tsun-ess.com Talent-MG2-WP/GP Step 4: Set zero export function on the monitor platform Login to the platform and find the "Solar Plant" page by Monitor ¹ Plants. Click it and enter the "Solar Plant" page. Find the "DTU" page by Device ¹ DTU. Click it and enter the "DTU" page. 21 www.tsun-ess.com Talent-MG2-WP/GP There is a "Device Control" button on the right-up conner. Click it and enter the "Device Control" page. Choose the "Set Zero Export" Command. Choose the "ON" Command. Click "Send Command" button. If the command is sent, it will show "Succeeded" in the page. Otherwise, it will show "Failed". 22 www.tsun-ess.com TSUNESS Co., Ltd www.tsun-ess.com sales@tsun-ess.com Building D2, No. 555, Chuangye Road , Jiaxing , Zhejiang Province, China ©2020 TSUNESS. All rights reserved. All specifications are subject to change without prior notice.