User Manual for TSun models including: Talent-MG2-WP, Talent-MG2-GP, Talent-MG2-WP Microinverter Monitor System, Microinverter Monitor System, Monitor System

User Manual Talent-MG2-WP Monitoring System

PDF User Manual Talent-MG2-WP Monitoring System

pro solarmanpv login site id


File Info : application/pdf, 25 Pages, 1.61MB

User Manual Talent-MG2-WP Monitoring System V1.4
STORE THE FUTURE
User Manual
Talent-MG2-WP Talent-MG2-GP
TSUNESS Co., Ltd

CONTENT
Read Me First
Warning Contact
Talent-MG2 Monitoring System
Packing List Product Appearance Technical Data Installation
Wi-Fi Configuration (Only Talent-MG2-WP)
LED Description
Website Configuration
Step 1: Install the microinverter and the monitoring device Step 2: Establish an account Step 3: Networking for the monitoring system Step 4: Create a Plant Step 5: Edit the system layout
Remote active power control function DRM function Zero export control function
Step 1: Confirm the loads' capacity for CT and Meter Step 2: Install the meter and CT Step 3: Connect the meter to the RS485 port of monitor device Step 4: Set zero export function on the monitor platform

Talent-MG2-WP/GP
1 1 1 2 2 3 4 5
7 8 9 9 9 10 12 14
15 15 16 16 17 20 21

www.tsun-ess.com

Talent-MG2-WP/GP
Read Me First
Dear customer, thank you for choosing the TSOL-M Series micro inverter from TSUNESS. We hope you will find our products meet your needs for renewable energy. Meantime, we appreciate your feedbacks regarding our products. This manual contains important instructions for Talent-MG2 Monitoring System. For safety, only qualified technician, who has received training or has demonstrated skills can install Talent-MG2 Monitoring System under the guide of this document.
Warning
Only qualified personnel should install, troubleshoot, or replace the monitoring system. Before installation, check the unit to ensure absence of any transport or handling damage, which could affect insulation integrity or safety clearances. All repairs should be carried out using only qualified spare parts, which must be installed in accordance with their intended use and by a licensed contractor or authorized TSUNESS service representative.
Contact
If you have technical problems about our products, contact the TSUN Service line.

TSUNESS Co., Ltd
Tel: +86 512 6618 6018 E-mail:sales@tsun-ess.com | www.tsun-ess.com Add: Building E1, No. 555, Chuangye Road, Dayun Town, Jiashan County,
Jiaxing City, Zhejiang Province, China

www.tsun-ess.com

1

Talent-MG2 Monitoring System

Talent-MG2-WP/GP

The Monitor Device is the key component in Talent-MG2 monitoring system. It is the relay station of the monitoring system, which operates between the microinverters and the Monitoring Server. The Monitor Device communicates with the microinverters in the system via 2.4G RF wireless to collect the data and status of the microinverters in the system. At the same time, Monitor Device connects to the Internet through WIFI (Talent-MG2-WP) or GPRS (Talent-MG2-GP), which realizes the information exchange with the monitoring service and sends all the running data of microinverters and status of the system to the monitoring server. It receives the control commands from the monitoring server and sends the data to the microinverters in the system to achieve remote operation and maintenance.
Packing List

a

b

c

d

Object a b c d

Description Monitor Device
Antenna Adaptor Bracket

Quantity 1 2 1 1

2

www.tsun-ess.com

Talent-MG2-WP/GP
Product Appearance

Object A B C D E F* G H

Description Power LED Communication LED (Server) Communication LED (Inverter) Alarm LED SD Card Slot SIM Card Slot Antenna (Wi-Fi/GPRS) RS485 Port

* Only Talent-MG2-G has a SIM Card Slot.

Object I J K L M N O

Description DRM Port (For Australia) Ethernet Port USB Port Reset Hole Power Port Antenna (2.4G) Installation Hole

3
www.tsun-ess.com

Technical Data
Model
Communication to Microinverter Signal Maximum Distance(Open Space) Monitoring Data Limit Communication to Server Sample Rate Signal Communication to Meter Signal Maximum Distance (RS485 Cable) Power Supply (Adapter) Type Input Voltage/Frequency Output Voltage/Current Power Consumption Mechanical Data Ambient Temperature(¥) Dimensions (W*H*D mm) Weight (kg) Mounting System Indicator Light

Talent-MG2-WP/GP

Talent-MG2-WP

Talent-MG2-GP

2.4G RF 100m 99 panels
Per 15 minutes Wi-Fi (802.11b/g/n) GSM (850/900/1800/1900MHz)
RS485 500m
External plug-in adapter 100 to 240V AC / 50 or 60Hz
5V DC / 2A 2.5W(typical), 5W(maximum)
-20~+55 200*101*29
0.2 Wall mounting / Desktop mounting
4 LED

4
www.tsun-ess.com

Talent-MG2-WP/GP
Installation 1.Take two antennas out from the box, screw the antenna into the Wi-Fi/GPRS port and 2.4G port. Note: While installing Talent-MG2-GP, there are a GSM antenna and a 2.4G antenna. Do not insert the antenna to the wrong port. Note: While the monitor device is installed inside the metal box or under the metal / concrete roof, extended 2.4G cable or 2.4G sucker antenna will be suggested.
2.Insert the SIM Card into the SIM Card Slot, press the SIM Card in until you heard "Click" (only for Talent-MG2-GP). 3.Screw the bracket on the wall and use at least two screw holes (one from each side) to fix the bracket (the M4 screws need to be prepared by installer).
5
www.tsun-ess.com

Talent-MG2-WP/GP
4.Match the bracket's upper buckle with monitor device. Then match the bracket's lower buckle by gently press the lower side of the monitor device until hear the"Click".
Note: Make sure the antennas are vertical to the wall. 5.Power on the monitor device. Note: Monitor device could also be put on the table. Make sure the antennas are vertical to the table.
6
www.tsun-ess.com

Talent-MG2-WP/GP
Wi-Fi Configuration (Only Talent-MG2-WP)
1.Connect the wireless name of MG2-W via computer or mobile phone. 2.Open the browser and enter 10.10.100.254 to open the Wi-Fi configuration page. The username and password are `admin' by default. 3.Click the Wi-Fi parameter menu on the left menu bar to enter the Wi-Fi parameter configuration.

4.Click the search button in the lower right corner, select the Wi-Fi name to be connected to the monitoring device.

5.Enter the password and click Save.
7

www.tsun-ess.com

Talent-MG2-WP/GP
6.Click Restart.

LED Description

LED Mark

LED Color

LED All LEDs

Status

Explanation Monitor device power on or power off
Network communication Microinverter communication
Fault State
Description
Firmware upgrading

www.tsun-ess.com

8

Talent-MG2-WP/GP

Starting up
Power on Power off Communicating with Server Internet disconnected Internet connected, Server disconnected Communicating with all microinverters Some microinverters disconnected No ID (Please do Networking) Normal Monitor device alarm Microinverter alarm Meter alarm
Website Configuration
Step 1: Install the microinverter and the monitoring device 1.Install the microinverter system. Please read the Quick Installation Guide or the User Manual of microinverter on www.tsun-ess.com/downloads before installation. 2.Install the monitoring device. Connect the power adapter into the socket 3.Make sure the microinverter system and the monitoring device are working well.
Step 2: Establish an account 1.Visit the monitor website pro.solarmanpv.com directly. Or enter this monitor website by the official website of TSUNESS www.tsun-ess.com .

9

www.tsun-ess.com

Talent-MG2-WP/GP
Click the "Register" button and register a new account.
Step 3: Networking for the monitoring system 1.Login to the platform and find the "Network" page by Applications ¹ Network. (Please make sure that the monitoring device has already connected to the server.)
10
www.tsun-ess.com

Talent-MG2-WP/GP
2.Click "+Select" to input the SN of monitoring device.
3. Click "Upload Network Relationship" to download the template file. After editing the file, click "Select a File" to upload file.

11

www.tsun-ess.com

Talent-MG2-WP/GP
Step 4: Create a Plant 1.Find the "Plants" page by Monitor ¹ Plants. Click `Create a Plant' to create a new plant.
2.Input basic information, system information, yield information and owner information in this page.
12
www.tsun-ess.com

Talent-MG2-WP/GP
3. Click "Save" and add a monitoring device in this plant. Click "add a New Gateway/Logger" and input the SN of the monitoring device.
4.All the plants can be viewed and managed in "Plants" page.
13
www.tsun-ess.com

Talent-MG2-WP/GP
Step 5: Edit the system layout 1.Find the "Plants" page by Monitor ¹ Plants ¹ "plant name" . Then enter the "Layout" page and click "Click here to edit system layout".
2.Drag the components to the right side to finish the physical layout.
14
www.tsun-ess.com

Talent-MG2-WP/GP
Remote active power control function
In some countries, it might require that the generating plants should be equipped with a logic interface (input port) in order to cease output active power or limit active power to a regulating level. This logic input can be RS485 port, Ethernet port, etc. Talent-MG2-WP/GP provide RTU Modbus protocol over RS485 port for this remote active power control. For more information, please refer to "Modbus implementation Technical Note".
DRM function
DRM port is provided to support several demand response modes as below by connecting external control device with a standard RJ-45 connector. For Talent-MG2-WP/GP, it can support DRM0/5/6/7/8 if used with TSUN microinverters.
Mode Requirement DRM0 Operate the disconnection device DRM1 Do not consume power DRM2 Do not consume at more than 50% of rated power DRM3 Do not consume at more than 75% of rated power AND Source reactive power if capable DRM4 Increase power consumption (subject to constraints from other active DRMs) DRM5 Do not generate power DRM6 Do not generate at more than 50% of rated power DRM7 Do not generate at more than 75% of rated power AND Sink reactive power if capable DRM8 Increase power generation (subject to constraints from other active DRMs)
15
www.tsun-ess.com

Talent-MG2-WP/GP

Zero export control function
To maintain the safety and quality level of the grid network, some countries' local grid authorities limit the PV generated power exporting to the grid. Zero export function can meet this requirement and help users install a bigger PV system without violating export regulations.
Step 1: Confirm the loads' capacity for CT and Meter
Make sure the CT/Meter range can cover the maximum loads power or PV system generating power. There are 3 types of CHINT meter and different types of CT that you can choose base on the actual installation requirement.

Meter Model Type

SN

Description

DDSU666(60A) Single Phase 10C011XXXXXX Direct connect, NOT via any kind of CT

DTSU666(80A) Three Phase 10C013XXXXXX Direct connect, NOT via any kind of CT

DTSU666(5A) Three Phase 10C012XXXXXX Compatible with 100A/5A, 300A/5A, and 600A/5A CT

Grid Type Single Phase System (230V) Three Phase System (230V/400V) Split Phase System (120V/240V) Three Phase System (120V/208V)

Meter Model DDSU666(60A)
DTSU666 (100A/5A,300A/5A, 600A/5A), DTSU666 (80A)

Note: There are several versions of CHINT meters in the market. The protocol in the meter is customermized for different inverter manufacturers. Please buy the CHINT meters from TSUN to ensure the usage of Zero Export Function.

16
www.tsun-ess.com

Step 2: Install the meter and CT CHINT DDSU666 Single Phase Meter (Direct connect)

Talent-MG2-WP/GP

Port 1 Port 2 Port 3 Port 4 Port 24 Port 25

input port, connect to the L line; output port, connect to the L line; connect to the N line; connect to the N line; connect to the A port of RS485 port connect to the B port of RS485 port

17
www.tsun-ess.com

Talent-MG2-WP/GP
CHINT DTSU666 Three Phase Meter (Direct connect)

Port 1 Port 3 Port 4 Port 6 Port 7 Port 9 Port 10 Port 24 Port 25

input port, connect to the L line of phase A; output port, connect to the L line of phase A; input port, connect to the L line of phase B; output port, connect to the L line of phase B; input port, connect to the L line of phase C; output port, connect to the L line of phase C; connect to the N line; connect to the A port of RS485 port connect to the B port of RS485 port

18
www.tsun-ess.com

CHINT DTSU666 Three Phase Meter (Via CT)

Talent-MG2-WP/GP

Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 Port 9 Port 10 Port 24 Port 25

connect to the red wire of CT in Phase A; connect to the L line of phase A; connect to the black wire of CT in Phase A; connect to the red wire of CT in Phase B; connect to the L line of phase B; connect to the black wire of CT in Phase B; connect to the red wire of CT in Phase C; connect to the L line of phase C; connect to the black wire of CT in Phase C; connect to the N line; connect to the A port of RS485 port connect to the B port of RS485 port

Make sure the CT (Current Transformer) has been installed in the right direction, otherwise will affect the current readings and Meter function. Meter install on the Load side, the CT arrow pointed to the Loads.

19
www.tsun-ess.com

Talent-MG2-WP/GP
Step 3: Connect the meter to the RS485 port of monitor device The picture below indicates the RS485 A Port and B Port on the monitor device.
When the RS485 cable length is more than 200m, use the shorting jumper on the first two ports from the RS485 port. For CHINT Single Phase Meter:
For CHINT Three Phase Meter:
20
www.tsun-ess.com

Talent-MG2-WP/GP
Step 4: Set zero export function on the monitor platform Login to the platform and find the "Solar Plant" page by Monitor ¹ Plants. Click it and enter the "Solar Plant" page.
Find the "DTU" page by Device ¹ DTU. Click it and enter the "DTU" page.
21
www.tsun-ess.com

Talent-MG2-WP/GP
There is a "Device Control" button on the right-up conner. Click it and enter the "Device Control" page.
Choose the "Set Zero Export" Command.
Choose the "ON" Command. Click "Send Command" button.
If the command is sent, it will show "Succeeded" in the page. Otherwise, it will show "Failed".
22
www.tsun-ess.com

TSUNESS Co., Ltd
www.tsun-ess.com sales@tsun-ess.com Building D2, No. 555, Chuangye Road , Jiaxing , Zhejiang Province, China
©2020 TSUNESS. All rights reserved. All specifications are subject to change without prior notice.



References

Adobe Illustrator CC 22.0 (Windows) Adobe PDF library 15.00