EBC-A40L User Manual

shao ke

EBC-A40L Battery Capacity Tester, Charge/Discharge 40A 200W, Voltage 0-5V, Current 0.1-40A, Blue

EBC-A40L Instructions for Use (IFU) (PDF) SanBouSi ANINZE EBC-A40L,Battery,Capacity,Tester,Charge/Discharge,40A,200W,Voltage,0-5V,Current,0.1-40A,Blue,,

EBC-A40L Battery Tester - (User Manual)

The first line shows mode (CC-constant current), voltage, and current. The second line shows working process, working time (in minute) and capacity ( ...

The first line shows mode (CC-constant current), voltage, and current. The second line shows working process, working time (in minute) and capacity ( ...

PDF preview unavailable. Download the PDF instead.

zketech-battery-tester-manual
ZKETECH
EBC-A40L Battery Tester User Manual
Release Date 2020-07-01

1. Features
The EBC-A40L tester is designed to charge and discharge batteries within 5V at a large current, the maximum current it supports is 40A in charging and 40A in discharging.
2. Specifications
3. Connecting pattern
3.1 Testing connector
3.2 PC connection The EBC-A40L tester can connect with a computer through a designated USB-TTL cable 3.3 Power supply: AC 200V
4. Display and setting
4.1 Buttons SET (1) ---- setting knob ON (2) ---- start and stop.
EBC-A40L User Manual Copyright (C) 2011-2020 ZKETECH

4.2 Testing interface
The first line shows mode (CC-constant current), voltage, and current. The second line shows working process, working time (in minute) and capacity (automatic switch between 0000mAh and 00.00Ah). Working process reads OFF when the test stops and DSC or CHG in testing. It shows AT1 if you choose automatic charging/discharging and 1 means the step 1 of current testing. A short press on the "SET" button and the display changes to power and energy.
In auto test of "charge-discharge-charge", you can check test results of each step by spin the "SET" knob.
Press the "ON" button to start discharging test (shows DSC) and one more press to stop (shows OFF). You can open setting interface by press on the "SET" button for 2 seconds in the stop state (This function is invalid when the tester being connected with the PC software). 4.3 Setting interface The cursor default is on mode setting. Press "SET" button to move it to the value you want to set up. Spin the "SET" knob to change parameters selected by the cursor. It will go back to the limit value if your setting exceeds the allowed range. Press "ON" button then move to the next item. 1) DSC-CC (Constant current discharge)
First line: mode and current setting. Second line: cut-off voltage (testing automatically stops when voltage reaches below this value) and the maximum testing time setting (no time limit if being set 0). 2) DSC-CP (constant power discharge)
EBC-A40L User Manual Copyright (C) 2011-2020 ZKETECH

First line: mode and power setting. Second line: cut-off voltage (testing automatically stops when voltage reaches below this value) the maximum testing time setting (no time limit if being set 0). 3) CHG-CV (constant voltage-current charge)
First line: mode and current setting. Second line: constant voltage, cut-off current (testing automatically stops when current reaches below this value; can be set above 0.1A), and the auto mode setting:  NOR ---- normal modetesting stops when charging finish.  AUTO ---- automatically go through the "charge-discharge-charge" round test. Put the cursor on AUTO and a long-time press on the "ON" button can lead to the setting of auto discharging parameters:
The first parameter is discharging current, and the second the cut-off voltage, the third is the waiting time for step switches (you are suggested to wait for 5-10 minutes between charging and discharging for the battery cooling). After you finish setting, press the "SET" button for a long time to return to the previous setting interface. Press "SET" button for a long time in the first-level setting interface to save data and go back to testing interface. After finish setting, press "ON" button to start testing. 4.4 Setting examples 1) Discharge setting (discharge the Lithium battery from 3.7V to 2.8V at 5A)
2) Charge setting (charge the Lithium battery from 3.7V to 4.2V at 2.5A, cut-off current is 0.11A)
EBC-A40L User Manual Copyright (C) 2011-2020 ZKETECH

3) Auto test setting (charge the 3.7V Lithium battery at 2.5A and discharge it at 5A, waiting time is 5 minutes)
5. Precautions
1) Positive and negative connections should not be reversed. 2) Always use the tester within the allowed range.
EBC-A40L User Manual Copyright (C) 2011-2020 ZKETECH

