TEST REPORT IEC 62841-1 Electric Motor ...

TEST REPORT IEC 62841-1 Electric Motor-Operated Hand-Held Tools, Transportable Tools and Lawn and Garden Machinery – Safety

[PDF] TEST REPORT IEC 62841-1 Electric Motor-Operated Hand-Held ...

*图或文字中所提及的配件,有些并不包括在供货范围. 内。 机器规格. WX822 WX822.X*. 电压. 20V. 最大**. 空载转速.

PDF preview unavailable. Download the PDF instead.

C168sH6oHsL ?ref=dp product quick view
.

Test Report issued under the responsibility of:

TEST REPORT IEC 62841-1
Electric Motor-Operated Hand-Held Tools, Transportable Tools and Lawn and Garden Machinery ­ Safety

Report Reference No. .....................: 191000962SHA-001

Date of issue.....................................: Nov 25, 2019

Amendment 1: Aug 09, 2021

Total number of pages......................: 11 pages

Applicant's name ............................: Positec Technology (China) Co., Ltd.

Address ............................................. :

18, Dongwang Road, Suzhou Industrial Park, Jiangsu 215123, P.R.China

Test specification:

Standard ...........................................: IEC 62841-1: 2014 (First Edition) + C1: 2014 + C2: 2015

Test procedure..................................: CE-MD

Non-standard test method..............: None

Test Report Form No. .....................: IEC62841_1B

Test Report Form(s) Originator ........: DEKRA Certification B.V.

Master TRF.......................................: 2019-04-12

Copyright © 2019 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

Page 2 of 11 Test item description....................... : Battery-powered Delta Sander

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

Trade Mark .........................................: WORX
Manufacturer.......................................: Same as applicant Model/Type reference.........................: WX822, WX822.* (* = A to Z or 0-9 which means different package
and/or accessories)

Ratings................................................: 20Vd.c., n0:12000/min

Remark ...............................................: All models are identical with each other except for the trade mark, package and/or accessories.

Battery charger system as below:
Battery pack WA3550 WA3550 WA3550 WA3550 WA3551 WA3551 WA3551 WA3551 WA3551 WA3553 WA3553 WA3553 WA3553 WA3553 WA3641 WA3641 WA3641 WA3641 WA3572 WA3572 WA3572 WA3572

Charger WA3760 WA3860 WA3869 WA3765 WA3760 WA3860 WA3869 WA3765 WA3880 WA3860 WA3880 WA3869 WA3760 WA3765 WA3760 WA3860 WA3869 WA3765 WA3860 WA3760 WA3869 WA3765

TRF No. IEC62841_1B

Page 3 of 11 Testing procedure and testing location:

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

Testing Laboratory:

Intertek Testing Services Shanghai Limited.

Testing location/ address.............................: Building No.86, 1198 Qinzhou Road (North), Shanghai 200233, China
Tested by (name + signature) ......................: Loki Ying (Certification Engineer)
Approved by (name + signature).................: Michael Shen (Mandated Reviewer)

Testing procedure: CTF Stage 1: Testing location/ address.............................: Tested by (name + signature) ......................: Approved by (name + signature).................:

Testing procedure: CTF Stage 2: Testing location/ address.............................: Tested by (name + signature) ......................: Witnessed by (name + signature)................: Approved by (name + signature).................:

Testing procedure: CTF Stage 3: Testing procedure: CTF Stage 4: Testing location/ address.............................: Tested by (name + signature) ......................: Witnessed by (name + signature)................: Approved by (name + signature).................: Supervised by (name + signature) ..............:

TRF No. IEC62841_1B

Page 4 of 11

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

List of Attachments (including a total number of pages in each attachment): Attachment: Photos, pages 11

Summary of testing:
The samples were tested according to IEC 62841-1: 2014 + C1: 2014 + C2: 2015 with EN deviation from EN 62841-1: 2015+AC: 15, IEC 62841-2-4: 2014 (First Edition) + C1: 2015 with EN deviation from EN 62841-2-4: 2014 and found to comply with the standards' requirements. Determination of the test conclusion is based on IEC Guide 115 in consideration of measurement uncertainty. Tests performed (name of test and test clause): Testing location:
Clause K.12.1, K12,201, K.18.1, K18,201, K18,202 Intertek Testing Service Shanghai Limited.
Building No.86, 1198 Qinzhou Road (North), Shanghai 200233, China

Summary of compliance with National Differences: List of countries addressed: EUROPEAN GROUP
The product fulfils the requirements of EN 62841-2-4: 2014 with EN 62841-1: 2015+AC: 15.

Copy of marking plate (representative): Please refer to Report No. 191000962SHA-001.

TRF No. IEC62841_1B

Page 5 of 11 Test item particulars .................................................. :

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

Category of equipment.............................................. : Hand held, Transportable, Lawn / Garden

Protection Class of tool............................................. : Battery-powered tool

Method of supply cord attachment ......................... : Battery-powered tool

Duty conditions .......................................................... : Normal, severe, extra-severe

Type of operation ....................................................... : Normal, short-time, intermittent

Degree of protection .................................................. : IP20

Accessories and detachable parts included .......... : Dust bag

Other options included.............................................. : N/A

Possible test case verdicts:

- test case does not apply to the test object ...........: N/A or N (Not Applicable)

- test object does meet the requirement ..................: P (Pass)

- test object does not meet the requirement ...........: F (Fail)

Testing ..........................................................................:

Date of receipt of test item.........................................: July 10, 2021

Date (s) of performance of tests ...............................: July 10, 2021 ­ Aug 09, 2021

General remarks:
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator.

Manufacturer's Declaration per sub-clause 4.2.5 of IECEE 02:

The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided................................................................:

Yes Not applicable

When differences exist, they shall be identified in the General product information section.

Name and address of factory (ies) ..........................: CHANGZHOU STADARD ELECTRIC APPLIANCE CO.,LTD
NO.29 The Chunqiu Road Minghuang Industrial Wujin Changzhou, P.R.China.

General product information: The products covered in this report are hand-held motor-operated battery-powered sanders.

Amendment 1:
The original report 191000962SHA-001 issued on Nov 25, 2019 was modified including following changes and/or additions:
1. Added alternative battery cells in component list.

TRF No. IEC62841_1B

Clause

Requirement + Test

Page 6 of 11 IEC 62841-1

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

Result - Remark

Verdict

23

COMPONENTS

P

23.1

Components comply with relevant IEC standards See Table 23.1

P

Batteries are regarded as part of the tool and comply

P

with Annexes K and/or L

Components used in accordance with their markings

P

Applied exceptions ...................................................:

N/A

Components not previously tested and found to

comply with the relevant IEC

P

comply with the relevant IEC standard for the

standard

number of cycles specified, tested to 23.1.1 ...

23.1.11 ......................................................................:

ANNEX K BATTERY TOOLS AND BATTERY PACKS

P

K.12.1

Tool operated at no-load until maximum temperature Until battery discharged

P

reached or battery discharged.................................:

No operation of protective devices during heating

P

test

Temperature rises met values in Table 2

P

K.12.201 Charging of lithium-ion battery under normal

P

conditions did not exceed specified operating region

for charging of the cell

Charging procedure as specified

P

Voltage, temperature and charging current

P

monitored for all individual cells

Test repeated with imbalanced battery

P

K.18.1

Risk of fire or electric shock as a result of abnormal

P

operation obviated as far as is practical

No charring or burning of gauze or tissue paper

See Table K.18.1

P

resulted when battery tool and battery pack were

subjected to any abnormal operations, tests a) to f)

No explosion during or after the test

P

Adequate protection against electric shock

P

Component(s) or conductors(s) that interrupt or limit See Table K.18.1

P

the discharge current that operated operate during

the above tests a) to f) ............................................:

Test repeated two more times for devices relied

P

upon to pass the test; devices opened the circuit in

the same manner

Test repeated with the open-circuited device bridged

N/A

TRF No. IEC62841_1B

Clause

Requirement + Test

Page 7 of 11 IEC 62841-1

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

Result - Remark

Verdict

Protective electronic circuits whose function is relied

N/A

on to pass a test regarded as providing a SCF and

comply with 18.8 with a PL = a

K.18.201 Risk of fire and explosion as a result of abnormal

P

operation during charging of a lithium-ion battery is

obviated as far as is practical

No charring or burning of gauze or tissue paper, no See Table K.18.201

P

explosion resulted when battery tool and battery

pack were subjected to any abnormal conditions a)

to d)

The cells did not exceed the upper limit charging

P

voltage by more than 150 mV unless...

...charging system permanently was disabled from

N/A

recharging the battery

No evident damage to the cell vent to impair

P

compliance with Subclause K.21.202.

K.18.202 No risk of fire or explosion when main discharge

P

connections of a series configured, integral Li-ion

battery, detachable or separable Li-ion battery pack

were shorted under extreme imbalance

All cells fully charged, one cell fully discharged

P

Main discharge connections of the battery were

P

shorted, resistance 10 m

No explosion during or after the test

P

No charring or burning of the gauze or tissue paper

P

Component(s) or conductors(s) that interrupt or limit

P

the discharge current that operated operate during

the above tests .......................................................:

Test repeated two more times for devices relied

P

upon to pass the test; devices opened the circuit in

the same manner

Test repeated with the open-circuited device bridged

N/A

Protective electronic circuits whose function is relied

N/A

on to pass a test regarded as providing a SCF and

comply with 18.8 with a PL = a

TRF No. IEC62841_1B

Clause

Requirement + Test

Page 8 of 11 IEC 62841-1

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

Result - Remark

Verdict

23.1

TABLE: Critical components information (Added in component list)

Object / part No. Manufacturer/ Type / model trademark

Battery cell

Jiangsu Tenpower Lithium Co., Ltd.

ICR18650 2000mAh

Union Lithplus

Alt

Energy (Liaoning)

L1865-2.0

Corp.

Technical data Standard

3,7V 2000mAh

Li-ion (For

battery pack WA3551 series

IEC 62133-2

and WA3553

series use)

3,6V 2000mAh

Li-ion (Only for

battery pack IEC 62133-2

WA3551 series

use)

P Mark(s) of conformity1)
CB/ DK86779-UL
CB/DK116083-UL

TRF No. IEC62841_1B

Clause

Requirement + Test

Page 9 of 11 IEC 62841-1

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

Result - Remark

Verdict

K12.1

TABLE: Normal Temperature Test for Battery Tool

Ambient temperature (°C) ...................................... : 21,0

Measurement at:

Temperature rise (K)

External enclosure of tool

5,0

External enclosure of battery pack

6,2

Handles, continuously held

3,5

Supplementary Information:

Test with battery pack WA3553 (Tenpower cell).

K12.1

TABLE: Normal Temperature Test for Battery Tool

Ambient temperature (°C) ...................................... : 21,0

Measurement at:

Temperature rise (K)

External enclosure of tool

4,8

External enclosure of battery pack

5,6

Handles, continuously held

3,1

Supplementary Information:

Test with battery pack WA3551 (Lithplus cell).

P  Allowed Limit (K) 60 60 50
P  Allowed Limit (K) 60 60 50

K.18.1 TABLE: Battery Tool Abnormal Operation

P

Abnormal conditions

Explosion Charring or Protector Test repeated occurred? burning of test Operated? 3 more times?
materials?

a) Terminals of detachable battery pack with exposed

N/A

terminals shorted

N/A

N/A

N/A

b) Motor terminals shorted

No

No

Yes

Yes

c) Motor rotor locked

No

No

Yes

Yes

d) Cord between battery tool and separable battery

N/A

pack shorted

N/A

N/A

N/A

e) Cord provided the tool and the charger shorted

N/A

N/A

N/A

N/A

f) Any two uninsulated parts of opposite polarity in

N/A

N/A

N/A

N/A

battery tools shorted

Supplementary Information: None.

TRF No. IEC62841_1B

Clause

Requirement + Test

Page 10 of 11 IEC 62841-1

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

Result - Remark

Verdict

K.18.201 TABLE: Lithium-ion charging systems ­ Abnormal Operation

Abnormal conditions

Explosion occurred?

Charring or burning of
test materials?

Upper limit charging voltage
not exceeded by >150 mV1)

Charging system permanently disabled?2)

a) Components in the charging

No

No

Yes

No

system faulted as in 18.6.1 b) to

f)

b) One cell 50% charged in a

N/A

N/A

N/A

N/A

fully discharged battery

c) Charging of a series

No

No

Yes

No

configured battery with all cells

50% charged, one cell shorted

d) Short across a component or

No

No

Yes

No

between adjacent PCB tracks

Supplementary Information: One of conditions 1) or 2) is sufficient to achieve compliance with this subclause.

P Cell vent damaged?
No
N/A No
No

TRF No. IEC62841_1B

Page 11 of 11 Photo

Report No. 191000962SHA-001 Amendment 1: Aug 09, 2021

Inner view of WA3551 (Lithplus cell)

Inner view of WA3553 (Tenpower cell) TRF No. IEC62841_1B

.

Test Report issued under the responsibility of:

TEST REPORT IEC 62841-2-4 Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery ­ Safety Part 2-4: Particular requirements for hand-held sanders and polishers other than
disk type

Report Reference No. .....................: 191000962SHA-002

Date of issue.....................................: Nov 25, 2019 Amendment 1: Aug 09, 2021
Total number of pages......................: 6 pages

Applicant's name ............................: Positec Technology (China) Co., Ltd.

Address.............................................: 18, Dongwang Road, Suzhou Industrial Park, Jiangsu 215123, P.R.China

Test specification:

Standard ...........................................: IEC 62841-2-4: 2014 (First Edition) + C1: 2015 for use in combination with IEC 62841-1: 2014 (First Edition) + C1: 2014 + C2: 2015
Test procedure..................................: CE-MD

Non-standard test method..............:

None

Test Report Form No. .....................: IEC62841_2_4A

Test Report Form(s) Originator ........: DEKRA Certification B.V.

Master TRF.......................................: 2014-09

Copyright © 2014 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

Page 2 of 6

Report No. 191000962SHA-002 Amendment 1: Aug 09, 2021

Test item description....................... : Battery-powered Delta Sander

Trade Mark .........................................: WORX
Manufacturer.......................................: Same as applicant Model/Type reference.........................: WX822, WX822.* (* = A to Z or 0-9 which means different package
and/or accessories)

Ratings................................................: 20Vd.c., n0:12000/min

Remark ...............................................: All models are identical with each other except for the trade mark, package and/or accessories.

TRF No. IEC62841_2_4A

Page 3 of 6 Testing procedure and testing location:

Report No. 191000962SHA-002 Amendment 1: Aug 09, 2021

Testing Laboratory:

Intertek Testing Services Shanghai Limited.

Testing location/ address.............................: Building No.86, 1198 Qinzhou Road (North), Shanghai 200233, China

Associated Testing Laboratory:

Testing location/ address.............................:
Tested by (name + signature) ......................: Loki Ying (Certification Engineer)
Approved by (name + signature).................: Michael Shen (Mandated Reviewer)

Testing procedure: TMP/CTF Stage 1: None Testing location/ address.............................: Tested by (name + signature) ......................: Approved by (name + signature).................:

Testing procedure: WMT/CTF Stage 2: None Testing location/ address.............................: Tested by (name + signature) ......................: Witnessed by (name + signature)................: Approved by (name + signature).................:

Testing procedure: SMT/CTF Stage 3 or 4:

None

Testing location/ address.............................:

Tested by (name + signature) ......................:

Witnessed by (name + signature)................:

Approved by (name + signature).................:

Supervised by (name + signature) ..............:

TRF No. IEC62841_2_4A

Page 4 of 6

Report No. 191000962SHA-002

Amendment 1: Aug 09, 2021

List of Attachments (including a total number of pages in each attachment):

None.

Summary of testing:
The samples were tested according to IEC 62841-1: 2014 + C1: 2014 + C2: 2015 with EN deviation from EN 62841-1: 2015+AC: 15, IEC 62841-2-4: 2014 (First Edition) + C1: 2015 with EN deviation from EN 62841-2-4: 2014 and found to comply with the standards' requirements.
Determination of the test conclusion is based on IEC Guide 115 in consideration of measurement uncertainty.
Tests performed (name of test and test clause): Testing location:
Clause K.12.1, K12,201, K.18.1, K18,201, K18,202 Intertek Testing Service Shanghai Limited.
Building No.86, 1198 Qinzhou Road (North), Shanghai 200233, China

Summary of compliance with National Differences: List of countries addressed: EUROPEAN GROUP
The product fulfils the requirements of EN 62841-2-4: 2014 with EN 62841-1: 2015+AC: 15.

Copy of marking plate (representative): Please refer to 191000962SHA-001 for copy of marking plate.

TRF No. IEC62841_2_4A

Page 5 of 6 Test item particulars .................................................. :

Report No. 191000962SHA-002 Amendment 1: Aug 09, 2021

Category of equipment.............................................. : Hand held, Transportable, Lawn / Garden

Protection Class of tool............................................. : Battery-powered tool

Method of supply cord attachment ......................... : Battery-powered tool

Duty conditions .......................................................... : Normal, severe, extra-severe

Type of operation ....................................................... : Normal, short-time, intermittent

Degree of protection .................................................. : IP20

Accessories and detachable parts included .......... : Dust bag

Other options included.............................................. : N/A

Possible test case verdicts:

- test case does not apply to the test object ...........: N/A or N (Not Applicable)

- test object does meet the requirement ..................: P (Pass)

- test object does not meet the requirement ...........: F (Fail)

Testing ..........................................................................:

Date of receipt of test item.........................................: July 10, 2021

Date (s) of performance of tests ...............................: July 10, 2021 ­ Aug 09, 2021

General remarks:

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator.

Manufacturer's Declaration per sub-clause 4.2.5 of IECEE 02:

The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided................................................................:

Yes Not applicable

When differences exist, they shall be identified in the General product information section.
Name and address of factory (ies) ..........................: CHANGZHOU STADARD ELECTRIC APPLIANCE CO.,LTD NO.29 The Chunqiu Road Minghuang Industrial Wujin Changzhou, P.R.China.

General product information: The products covered in this report are hand-held motor-operated battery-powered sanders.
Amendment 1: The original report 191000962SHA-002 issued on Nov 25, 2019 was modified including following changes and/or additions:

TRF No. IEC62841_2_4A

Page 6 of 6 1. Added alternative battery cells in component list.

Report No. 191000962SHA-002 Amendment 1: Aug 09, 2021

TRF No. IEC62841_2_4A

 

AP01364901 

 (5)

Pantone 151C
(100h)
(100h),
 P151C

iconM100Y100

 UV 

12000 OPM 20V

WX822.9
20V Cordless Detail Sander

LOW VIBRATION

12000 OPM 20V
WX822.9
20V Cordless Detail Sander

12000 OPM 20V

WX822.9
20V Cordless Detail Sander

YEARS

*

LIMITED

WARRANTY

LOW VIBRATION

AP01364901

Battery not included

LOW VIBRATION

FINGER SANDING

HOOK & LOOP

TOOL ONLY**

FINGER SANDING

HOOK & LOOP
TOOL ONLY**

Copyright © 2023, Positec. All Rights Reserved.

* EN See warranty card for more details D Weitere Details siehe Garantiekarte F Voir carte de garantie pour plus de détails I Per maggiori dettagli vedere la scheda di garanzia ES Para obtener más información, consulte la tarjeta de garantía PT Para obter mais informações, consulte o cartão de garantía NL Zie garantiekaart voor meer informatie DK Se garantibeviset for yderligere oplysninger RU  .  

NOR Se garantikortet for ytterligere informasjon SV Läs på garantikortet för mer information PL Wicej informacji zawarto w karcie gwarancyjnej GR .      HU További részletekért lásd a jótállást RO Consultai cardul de garanie pentru mai multe detalii CZ Podrobné informace jsou uvedeny na zárucním list SK Podrobné informácie sú uvedené na zárucnom liste SL Za podrobnosti, glejte garancijski list

12000 OPM 20V

WX822.9
20V Cordless Detail Sander

FINGER SANDING

HOOK & LOOP

TOOL ONLY**

NOR Bare verktøy, batteri og lader ikke inkludert. SV Endast verktyget, batteri och laddare ingår ej. PL Tylko narzdzie, zestaw nie zawiera baterii ani ladowarki. GR  ,       . HU Csak eszköz, elemet és töltt nem tartalmazza. RO Doar unealta, acumulatorul i încrctorul nu sunt incluse. CZ Pouze pístroj, nabíjecka baterií není soucástí balení. SK Len nástroj, balenie nezaha batériu ani nabíjacku. SL Samo orodje, baterija in polnilnik nista prilozena.

** EN Tool only, battery and charger not included. D Nur Werkzeug; Akku und Ladegerät nicht enthalten. F Outil uniquement, batterie et chargeur non inclus. I Solo lo strumento, la batteria e il caricabatteria non sono inclusi. ES Solamente herramienta, batería y cargador no incluidos. PT Apenas ferramenta, bateria e carregador não incluídos. NL Alleen gereedschap, batterij en oplader niet inbegrepen. DK Kun værktøj, batteri og oplader medfølger ikke. RU  ,     .

12000 OPM 20V

WX822.9
20V Cordless Detail Sander

3

3

EN Dustop micro filter for a cleaner working environment D Dustop-Mikrofilter für ein sauberes Arbeitsumfeld F Micro filtre Dustop pour un environnement de travail plus propre I Dustop Microfiltro per un ambiente di lavoro più pulito ES Micro filtro Dustop para un ambiente de trabajo más limpio PT Micro filtro Dustop para um ambiente de trabalho mais limpo NL Dustop-microfilter voor een schonere werkomgeving DK Dustop mikrofilter giver et renere arbejdsmiljø RU      NOR Dustop-mikrofilter for et renere arbeidsmiljø SV Dustop-mikrofilter för en renare arbetsmiljö PL Dustop-Mikrofiltr zapewnia czystsze rodowisko pracy GR  Dustop     HU Dustop mikroszr a tisztább munkakörnyezet érdekében RO Dustop microfiltru ofer un mediu de lucru mai curat CZ Dustop-Mikrofiltr pro cistsí pracovní prostedí SK Dustop Mikrofilter pre cistejsie pracovné prostredie SL Dustop mikro filter za cistejse delovno okolje

FINGER SANDING
EN Detail pad reaches into corners and hard-to-reach spots D Detail Pad erreicht Ecken und enge, schwer erreichbare Räume F Le pavé de détail atteint les coins et les espaces restreints I Il pad di dettaglio può arrivare agli angoli e spazi ristretti ES La almohadilla de detalle alcanza esquinas y espacios reducidos PT Almofada de detalhes atinge cantos e espaços apertados NL Detailkussen in de hoek en smalle ruimte
DK Detailpude ind i hjørnet og smalt rum
RU         NOR Detaljpute inn i hjørnet og smalt rom
SV Detaljplatta i hörnet och det smala utrymmet PL Podkladka z detalami w rogu i wskiej przestrzeni GR          HU Részlet pad a sarokba és keskeny tér
RO Placa de detalii în col i spaiul îngust
CZ Náhradní brusní spicka ve tvaru prstu pro brousení v rozích a úzkých prostorech. SK Brusná spica vo tvaru pstu pre brúsenie v rohoch a v malých priestoroch SL Detaljna blazinica za brusenje v kotih in tezje dostopnih mestih

HOOK & LOOP
EN Hook and loop easy paper change
D Klettpapier für bequemen Papierwechsel
F Changement aisé du papier grâce au système velcro I Carta abrasiva con sistema a velcro
ES Sistema de enganche y cierre para un sencillo cambio del papel PT Troca de lixa fácil ­ sistema encaixa - e gira NL Gemakkelijk papier verwisselen met klitteband systeem DK Nem udskiftning af papir med velcrolukning RU        NOR Enkelt papirskifte med "borrelås"
SV Sätt fast och kör, enkelt pappersbyte
PL Tarcza z mocowaniem na rzep, do latwej zmiany papieru GR    HU Egyszer tépzáras dörzspapír-csere
RO Sistemul de prindere a mirghelului pe suport permite schimbarea rapid a acesteia CZ Snadná výmna brusného papíru na suchý zip SK Podlozka so suchým zipsom pre jednoduchú výmena brúsneho papiera SL Enostavna menjava papirja z zadrgo

LOW VIBRATION
EN Low vibration increases gripping comfort and reduces fatigue
D Geringe Vibrationen erhöhen den Griffkomfort und verringern die Ermüdung
F Les basses vibrations augmentent le confort de préhension et réduisent la fatigue
I Le basse vibrazioni aumentano il comfort di presa e riducono l'affaticamento
ES Las bajas vibraciones aumentan la comodidad de agarre y reducen la fatiga
PT Baixa vibração aumenta o conforto e reduz a fadiga
NL Lage vibratie voor verbeterd gripcomfort en minder vermoeidheid
DK Lav vibration for forbedret grebkomfort og reduceret træthed
RU        
NOR Lav vibrasjon for forbedret grepkomfort og redusert tretthet
SV Låg vibration för förbättrad greppkomfort och minskad trötthet
PL Niski poziom wibracji dla lepszego komfortu chwytu i zmniejszenia zmczenia
GR            
HU Alacsony vibráció a jobb kényelem és a csökkent fáradtság érdekében
RO Vibraii sczute pentru un confort de aderen îmbuntit i oboseal redus
CZ Nízké vibrace pro lepsí pohodlí pi uchopu a snízenou únavu
SK Nízke vibrácie pre lepsie drzanie a znízenú únavu
SL Nizka vibracija za boljse udobje pri oprijemu in manjso utrujenost

20V Max Lithium Ion n0: 12000/min
POSITEC Germany GmbH Grüner Weg 10, 50825 Cologne, Germany Made in China/Fabriqué en Chine/Hergestellt in China

WX822.9

: AQ02571800 : 47x14.5mm : PET : +P151C :

 20V 

WX822 WX822.X


  

"" 
a)  1) 
 2) 
  3)  

   4)    5)    6)    7)    8)   

b)  1) 


d)  1) 








2) 

2) 



2





3) 

3) 



/

4) 









4) 





5) 









5) 

6) 



RCD



RCD





c) 

6) 

1)     
2)   

 7) 
   8)   

 3) /

e) 

20V 

WX822 WX822.X

1)   
2)  
3)     
4)     
5)   
6)  130  
f)  1) 
 2) 


q)  
r) (20±5) s)  t)  u)  v) 









3


 a)  b) 
 c) 
  d)   e)  f)    g)  h) (+)()  i)  j)  k)  l)  m)  n)  o)    p) 


  
Li-I on 
 Li-I on

20V 

WX822 WX822.X

1

2

3

4
5
4

7

6

9 8

20V 

WX822 WX822.X

A

B

8

C

D

5

E
G1
20V 

F 1 2
G2
WX822 WX822.X

G1
H1
6

G2 H2
9

20V 

WX822 WX822.X



WA3760

0.4A

1.  2.  3.  4. 

20V 

WA3860

2.0A

WA3880

2.0A

  

5.  6.  7. 




8. *
9.  *
* 

 








 

. A

 

WX822 WX822.X* 20V ** 12000/

 :  


. B



140x90



. C

7



2



. D



0.8 



* X=1-99A-ZM1-M9  ** 20V18V









WA3550 WA3550.1

1.5Ah 1.5Ah

 /  

.E



. F

 5-10 

. G1,G2

  
  

. H1,H2

20V 

WA3551 WA3551.1 WA3639 WA3553 WA3644

2.0Ah 2.0Ah 2.0Ah 4.0Ah 4.0Ah


2~3         

20V 

WX822 WX822.X

      


       


0-45 0-40





8







20V 

WX822 WX822.X




          

Pb
  × × × × × 



Hg
       





Cd 

 Cr(VI)


×



































 PBB
       



 PBDE
       



GB/T 26572 ×GB/T 26572  
9
25   " "" "
 1.  2.  3.  4. :  5.  6. 

GB/T 3883.204-2019 GB 4343.1-2018

20V 

WX822 WX822.X

10

20V 

 18 215123
 AR01477201
WX822 WX822.X


400 887 9955

 18215123
www.worx.com



12 
 ·  ·  ·  ·  ·  · 

www.worx.com


400 887 9955

 18215123
www.worx.com








_______________/ _______________________________________________

  20  20-29

 30-39

 40-49

 50

    

___________________________________________/______________________________

________________________________ _____________________________________________

___________________________ _____________________________________________

______________________________________________________________________________ ____________________ ______________________________________________

___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________ _________________________________________








_______________/ _______________________________________________

  20  20-29

 30-39

 40-49

 50

    

___________________________________________/______________________________

________________________________ _____________________________________________

___________________________ _____________________________________________

______________________________________________________________________________ ____________________ ______________________________________________

___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________ _________________________________________

XRF Screening and chemical confirmation test report

Number: 220301014SHA

Applicant:

POSITEC TECHNOLOGY(CHINA) CO., LTD No.18 Dongwang Road, Industrial Park, Suzhou, China.

Date:

Mar. 11, 2022

Sample Description:

Item Name

: 20V delta sander

Tested Model

: WX822

***************************************************************************************************************************************************** Tests conducted:
As requested by the applicant, for details refer to attached page(s). Remark:
As requested by the applicant, only the selected components list in this report were tested, and other components not mentioned were not conducted. ***************************************************************************************************************************************************** Conclusion:

Tested sample

Standard

Result

Submitted samples

Restriction of the use of certain hazardous substance in electrical and

Pass

electronic equipment (RoHS Directive 2011/65/EU and (EU) 2015/863)

*****************************************************************************************************************************************************

To be continued

Authorized by: For Intertek testing services Ltd., Shanghai
Jonny Jing Operation Director

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 1 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

Tests Conducted

Cadmium (Cd), Lead (Pb), Mercury (Hg), Chromium (Cr) and Bromine (Br) content were measured with reference to IEC 62321-3-1 Edition 1.02013 by XRF spectroscopy and chemical confirmation test for RoHS restricted substances. And Phthalates content were determined by Gas Chromatographic-Mass Spectrometric (GC-MS).

(A) Results:

Part

Tested

No. Components

Refer information

1

Housing

Restricted XRF Substance Result

Screened Results (phthalates)

Chemical Confirmation
Result

Conclusion on RoHS

Cd

P

/

Pb

P

/

Hg

P

NA

/

1-1

Housing(Blac k plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

1-2

Orange plastic

/

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

1-3

Black soft plastic

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 2 of 51

XRF Screening and chemical confirmation test report (A) Results:

Number: 220301014SHA

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Switch

1-4

cover(Black

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

1-5 Black plastic

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

1-6 Black plastic

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 3 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

1-7

Screw(Black metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

2 Switch set

Cd

P

/

Pb

P

/

Hg

P

NA

/

2-1

Sleeve(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

2-2 jacket(Brown

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 4 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Wire

2-3

jacket(Red

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

2-4

jacket(Blue

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

2-5

Button(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 5 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Switch

2-6

case(Black

/

plastic)

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

Cr

P

/

2-7 Silvery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

Contact

2-8 point(Silvery

/

metal)

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 6 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

2-9

PCB(Green nonmetal)

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

2-10

Solder(Silvery metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

3 Motor

Cd

P

/

Pb

P

/

Hg

P

/

Cr

P

/

3-1 Silvery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 7 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

Cr

X

Cr6+=Negative

3-2 Silvery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

3-3

Washer(Brown plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

/

3-4 White plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 8 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

Carbon

3-5 brush(Coppery

/

metal)

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

Cr

P

/

3-6 Coppery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

Cr

P

/

3-7 Golden metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 9 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

3-8

Wire(Coppery metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

3-9

Inductor(Black nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

3-10

Capacitor(Bro wn nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 10 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

Cr

P

/

3-11 Black metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

3-12

Magnet(Black nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

3-13

Filling(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 11 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

Cr

P

/

3-14 Coppery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

Cr

X

Cr6+=Negative

3-15 Green metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

4 Electrode base

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

4-1

jacket(Black

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 12 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Wire

4-2

jacket(Black

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

4-3

jacket(Blue

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

4-4

Wire(Silvery metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 13 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Electrode

4-5

base(Black

/

plastic)

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

Electrode

4-6

slice(Silvery

/

metal)

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

5 Fan set

Cd

P

/

Pb

P

/

Hg

P

NA

/

5-1

Washer(Green plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 14 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Cr

P

5-2

Fan(Black plastic)

/

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

/

5-3 Black plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

5-4

Ring(Golden metal)

/

Cr

X

Cr6+=Negative

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 15 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

5-5

Holder(Silvery metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

5-6

Ball(Silvery metal)

/

Cr

X

Cr6+=Negative

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

Bearing

5-7 case(Silvery

/

metal)

Cr

X

Cr6+=Negative

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 16 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

5-8

Washer(Black metal)

/

Cr

X

Cr6+=Negative

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

Cr

X

Cr6+=Negative

5-9

Black metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

5-10

Screw(Silvery metal)

/

Cr

X

Cr6+=Negative

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 17 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

6 Base set

Chemical Confirmation
Result

Conclusion on RoHS

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

/

6-1 Black plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

/

6-2 Orange plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

6-3

Sponge(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 18 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

6-4

Hook(Black plastic)

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

X

Pb=20220ppm#1

Hg

P

/

Cr

P

/

6-5 Golden metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

/

6-6 Black plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 19 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

Cr

P

/

6-7 Silvery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

6-8

Fabric(Black nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

6-9

Washer(Silver y metal)

/

Cr

X

Cr6+=Negative

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 20 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

6-10

Screw(Black metal)

/

Cr

X

Cr6+=Negative

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

/

6-11 White plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

7 Assist set

Cd

P

/

Pb

P

/

Hg

P

NA

/

7-1

Hook(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 21 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Cr

P

/

7-2 Black plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

7-3

Sponge(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

7-4

Screw(Black metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 22 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

8 Dust bag

Chemical Confirmation
Result

Conclusion on RoHS

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

/

8-1 Black plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Fabric

Cr

P

8-2

bag(Black

/

Br

P

nonmetal)

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

8-3

O-ring(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 23 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

9 Charger

Chemical Confirmation
Result

Conclusion on RoHS

Cd

P

/

Pb

P

/

Charger

9-1

case(Black

/

plastic)

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

9-2

Cable(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Plug

9-3

case(Black

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 24 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Wire

9-4

jacket(Blue

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

9-5 jacket(Brown

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

9-6

Wire(Coppery metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 25 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Pin

9-7 holder(Black

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

X

Pb=6169ppm#1

Hg

P

/

Pin(Coppery

9-8

metal with

/

silvery plating)

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

9-9

Screw(Black metal)

/

Cr

X

Cr6+=Negative

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 26 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

9-10 Black plastic

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

9-11

Tie(Black plastic)

/

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Light

9-12 guide(Transpa

/

rent plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 27 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

9-13

Label(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

9-14

LED(White nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

9-15

Glue(White plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 28 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Cr

P

/

9-16 White plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

9-17

EC(Black nonmetal)

/

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

Cr

P

/

9-18 Silvery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 29 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

9-19

Capacitor(Gre en nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

9-20

Capacitor(Blac k nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

9-21

Capacitor(Blue nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 30 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Capacitor

9-22 case(Yellow

/

plastic)

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

9-23

Film(Silvery metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Capacitor

9-24 case(Black

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 31 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Cr

P

/

9-25 Black rubber

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

9-26

Paper(Yellow nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

Capacitor

9-27 case(Silvery

/

metal)

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 32 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Cr

P

/

9-28 Brown plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

/

Cr

X

Cr6+=Negative

9-29 Silvery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

9-30

Inductor(Black nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 33 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

9-31

Wire(Coppery metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

9-32

Sleeve(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

/

9-33 Black plastic

/

Br

P

/

PASS

DEHP

NA

BL

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 34 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

9-34

Tape(Yellow plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Cr

P

9-35

EC(Black nonmetal)

/

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

9-36

PCB(Green nonmetal)

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 35 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

9-37

Solder(Silvery metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

9-38 jacket(Black

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

9-39 jacket(Yellow

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 36 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Wire

9-40 jacket(Green

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

9-41

jacket(Red

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Electrode

9-42 base(Black

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 37 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

Cr

P

/

9-43 Silvery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

10 Battery pack

Cd

P

/

Pb

P

/

10-1

Case(Black plastic)

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

10-2

Button(Orange plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 38 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

10-3

Screw(Black metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

10-4

Spring(Black metal)

/

Cr

P

Br

NA

NA

DEHP

NA

/

/

PASS

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

10-5

Label(Black plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 39 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

10-6

Sponge(Black plastic)

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

10-7 Black plastic

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

10-8 Black plastic

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 40 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

/

Cr

P

/

10-9 Silvery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

/

Cr

P

/

10-10 Silvery metal

/

Br

NA

NA

/

PASS

DEHP

NA

/

BBP

NA

/

DBP

NA

/

DIBP

NA

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

10-11

Paper(Red nonmetal)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 41 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

10-12

Glue(White plastic)

/

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

10-13 jacket(White

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

10-14 jacket(Black

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 42 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.

Tested Components

Refer information

Restricted XRF Substance Result

Screened Results (phthalates)

Cd

P

Chemical Confirmation
Result
/

Conclusion on RoHS

Pb

P

/

Hg

P

NA

/

Wire

10-15 jacket(Yellow

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

Hg

P

NA

/

Wire

10-16 jacket(Red

/

plastic)

Cr

P

Br

P

DEHP

NA

BL

/

/

PASS

/

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

Cd

P

/

Pb

P

/

10-17

PCB(Green nonmetal)

/

Hg

P

NA

Cr

P

Br

X

DEHP

NA

BL

/
/ PBB=ND PBDE=ND
/

PASS

BBP

NA

BL

/

DBP

NA

BL

/

DIBP

NA

BL

/

*****************************************************************************************************************************************************

To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 43 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

(A) Results:

Part No.
10-18

Tested Components
Solder(Silvery metal)

Refer information
/

Restricted XRF Substance Result

Cd

P

Pb

P

Hg

P

Cr

P

Br

NA

DEHP

NA

BBP

NA

DBP

NA

DIBP

NA

Screened Results (phthalates)
NA

Chemical Confirmation
Result / / / / / / / / /

Conclusion on RoHS
PASS

Remark: P = pass (Below the lower screening limit of table (B1)) X = inconclusive result (Further chemical test was suggested (see table (B1).) BL=Below the lower screening limit of table (B2) and pass NA = not applicable ND = not detected ppm = Parts per million = mg/kg Negative=The Cr (VI) concentration is less than 0.10 µg/cm2.The sample is negative for Cr (VI).
(#1) = As claimed by the declaration submitted by the client, the Lead content of the components is coming from copper alloy, the limit for Lead is 40,000ppm.
***************************************************************************************************************************************************** To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 44 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

Tests Conducted

(B) (B1) XRF Screening Limits in mg/kg for Regulated Elements in Various Matrices.

Element Cd Pb Hg Cr Br

Polymer materials P 70 < X < 130  F P  700 < X < 1300 F P  700< X < 1300  F P  700< X P  300< X

Metallic materials P  70 < X < 130  F P  700 < X < 1300  F P  700 < X < 1300  F P  700 < F Not applicable

Composite materials P  70 < X < 150  F P  500< X < 1500  F P  500 < X < 1500  F P  500 < X P  250 < X

(B2) Preliminary screening test will used for phthalates, if the results exceed the warning area in the following table, further chemical methods will conduct to confirm the exact content by GC/MS.

Phthalates Bis(2-ethylhexyl)phthalate(DEHP)
Butyl benzyl phthalate(BBP) Dibutyl phthalate(DBP)
Diisobutyl phthalate(DIBP)

Polymer BL 600<X BL 600<X BL 600<X BL 600<X

(C) Estimated detection limits in mg/kg for regulated elements in various matrices.

Element Cd Pb Hg Cr Br

Polymer materials 50 100 100 100 200

Metallic materials 70 200 200 200
Not applicable

Composite materials 70 200 200 200 200

************************************************************************************************************************************************************ Disclaimers:
This XRF screening report is for reference purposes only. The applicant shall make its/his/her own judgment as to whether the information provided in this XRF screening report is sufficient for its/his/her purposes.
The results shown in this XRF screening report will differ based on various factors, including but not limited to, the sample size, thickness, area, surface flatness, equipment parameters and matrix effect (e.g. plastic, rubber, metal, glass, ceramic etc.). Further wet chemical pre-treatment with relevant chemical equipment analysis is required to obtain quantitative data. *****************************************************************************************************************************************************
To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 45 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

Tests Conducted (D) Chemical confirmation test methods

Testing Item

Testing Method

Reporting Limit

Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content

With reference to IEC 62321-5 Edition 1.0:2013, by acid digestion until the tested sample was totally dissolved and determined by ICP - OES With reference to IEC 62321-5 Edition 1.0:2013, by acid digestion until the tested sample was totally dissolved and determined by ICP - OES With reference to IEC 62321-4 Edition 1.1:2017, by acid digestion until the tested sample was totally dissolved and determined by ICP - OES

2 mg/kg 2 mg/kg 2 mg/kg

Chromium (VI)(Cr6+) Content

With reference to IEC 623217-2 Edition 1.0:2017, by alkaline digestion and determined by UV-VIS Spectrophotometer

10 mg/kg

Positive(>0.13 g/cm2) /

Chromium (VI) (Cr6+)

With reference to IEC 62321-7-1 Edition 1.0:2015, by boiling

Negative(<0.10 g/cm2) /

Content

water extraction and determined by UV-VIS Spectrophotometer. Inconclusive(0.10g/cm2 -

-0.13 g/cm2)

Polybrominated Biphenyls (PBBs)& Polybrominated Diphenyl Ethers (PBDEs) Content

With reference to IEC 62321-6 extraction and determined by confirmation when necessary

Edition 1.0:2015, by solvent GC/MS and further HPLC

5 mg/kg

Phthalates (DEHP, BBP, With reference to IEC 62321-8 Edition 1.0:111/321/CD, by

DBP, DIBP) Content

solvent extraction and determined by GC/MS

100mg/kg

(E) RoHS requirement

Restricted Substances Cadmium (Cd) Lead (Pb) Mercury (Hg) Chromium (VI) (Cr6+) Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ethers (PBDEs) Phthalates (DEHP, BBP, DBP, DIBP)

Limits 0.01% (100 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg) 0.1% (1000 mg/kg)

The above limits were quoted from 2011/65/EU and (EU) 2015/863 for homogeneous material.

Date sample received: Mar. 08, 2022 Testing period: Mar. 08, 2022 To Mar. 11, 2022 ************************************************************************************************************************************************************
To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 46 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

Tests Conducted

Photo of test components

220301014SHA

1

2

3

4

220301014SHA
5 6

8 7

220301014SHA
9

220301014SHA
10

220301014SHA

1-1 1-2

1-3

1-4

1-4

1-5 1-6

220301014SHA

2-2 2-3 2-1

2-4 2-5

2-6 2-7 2-8

2-9 2-10

************************************************************************************************************************************************************ To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 47 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

220301014SHA

Photo of test components
220301014SHA

3-1 3-2 3-3 3-4

3-5

3-6 3-7 3-8 3-9 3-10

3-11 3-12

3-14

3-13

3-15

220301014SHA

4-1

4-2

4-3 4-4 4-5 4-6

220301014SHA

5-2 5-1

5-3 5-4 5-5

5-6

5-7

5-8 5-9 5-10

220301014SHA

7-1

7-2

7-3

7-4

220301014SHA

8-1 8-2 8-3

8-4

8-5

8-6

8-7

************************************************************************************************************************************************************ To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 48 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

Photo of test components

220301014SHA
9-1 9-2 9-3

220301014SHA

9-9 9-10

9-11 9-12 9-13

9-4 9-5 9-6 9-7 9-8

9-14 9-15 9-16 9-17

9-18

220301014SHA
9-19 9-20 9-21 9-22 9-23

9-24 9-25 9-26

9-27 9-28

220301014SHA
9-29 9-30 9-31 9-32 9-33

9-34 9-35

9-36 9-37

220301014SHA

9-38 9-39 9-40 9-41

9-42 9-43

220301014SHA

10-1 10-2

10-4 10-5

10-3

10-6

10-7 10-8 10-9

************************************************************************************************************************************************************ To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 49 of 51

XRF Screening and chemical confirmation test report Photo of test components
220301014SHA
10-10 10-11 10-1210-13

Number: 220301014SHA

10-14 10-15 10-16 10-14 10-18

************************************************************************************************************************************************************ To be continued

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 50 of 51

XRF Screening and chemical confirmation test report

Number: 220301014SHA

Tests Conducted

Photo of whole tested product(s)

220301014SHA

220301014SHA

220301014SHA

220301014SHA

Remark
The tested samples were confirmed by client and reference models were based on the self-declaration supplied by clients.
Intertek takes no responsibility for any issues of product consistency caused by inaccurate and/or invalid information submitted by
the client. ************************************************************************************************************************************************************
End of report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.

Intertek Testing Services Ltd., Shanghai 

Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233 801B
200233

Tel: +86 21 6127 8200 Fax: +86 21 6495 6263 www.intertek.com www.intertek.com.cn

Page 51 of 51

Test Verification of Conformity

Verification Number: 191000961SHA-V1

On the basis of the referenced test report(s), sample(s) tested of the below product have been found to comply with the standards harmonized with the directives listed on this verification at the time the tests were carried out. Other standards and Directives may be relevant to the product. This verification is part of the full test report(s) and should be read in conjunction with it <them>.

Once compliance with all product relevant

mark directives are verified, including any relevant e.g. risk

assessment and production control, the manufacturer may indicate compliance by signing a Declaration of

Conformity themselves and applying the mark to products identical to the tested sample(s).

Applicant Name & Address:
Manufacturing site Name&Address: Product Description: Ratings & Principle Characteristics: Models/Type References:
Brand Name(s): Standard(s)/Directive(s):
Verification Issuing Office Name & Address: Date of Tests Test Report Number(s):

Positec Technology (China) Co., Ltd. 18, Dongwang Road, Suzhou Industrial Park, Jiangsu 215123, P.R.China CHANGZHOU STADARD ELECTRIC APPLIANCE CO., LTD NO.29 The Chunqiu Road Minghuang Industrial Wujin Changzhou, P.R. China. Battery-powered Delta Sander 20Vd.c., n0:12000/min
WX822, WX822.* (* = A to Z or 0-9 which means different package and/or accessories) WORX EN 55014-1:2017 EN 55014-2:2015 the EMC directive(2014/30/EU) Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North), Shanghai 200233, China November 20, 2019 191000961SHA-001

Signature
Name: Jonny Jing Position: Operation Director Date: November 27, 2019

This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

Intertek

Page 1 of 1

GFT-OP-11b (22-February-2018)

Positec Technology (China) Co., Ltd.
TEST REPORT
SCOPE OF WORK: EMC directive (2014/30/EU) ­ EMC report
Model: WX822, WX822.* (* = A to Z or 0-9 which means different package and/or accessories)
REPORT NUMBER 191000961SHA-001
ISSUE DATE November 27, 2019
DOCUMENT CONTROL NUMBER
TTRF55014-01_V1 © 2018 Intertek

Intertek Testing Services Shanghai, Building No.86, 1198 Qinzhou Road (North),
Caohejing Development Zone, Shanghai 200233, China
Telephone: 86 21 6127 8200 www.intertek.com

Report no. 191000961SHA-001

Applicant

: Positec Technology (China) Co., Ltd. 18, Dongwang Road, Suzhou Industrial Park, Jiangsu 215123, P.R.China

Manufacturer

: Positec Technology (China) Co., Ltd. 18, Dongwang Road, Suzhou Industrial Park, Jiangsu 215123, P.R.China

Manufacturing site

: CHANGZHOU STADARD ELECTRIC APPLIANCE CO., LTD NO.29 The Chunqiu Road Minghuang Industrial Wujin Changzhou, P.R.China

Summary
The equipment complies with the requirements according to the following standard(s) or Specification:
EN 55014-1:2017: Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 1: Emission

EN 55014-2:2015: Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity ­ Product family standard

PREPARED BY:

REVIEWED BY:

Hao Liang Project Engineer

Star Guo Reviewer

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

TTRF55014-01_V1 © 2018 Intertek

Page 2 of 52

Report No. 191000961SHA-001

Contents

REVISION HISTORY................................................................................................................................................ 5

MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6

1. GENERAL INFORMATION ............................................................................................................................. 7

1.1 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 7 1.2 DESCRIPTION OF TEST FACILITY .............................................................................................................................. 8

2. TEST SPECIFICATIONS................................................................................................................................... 9

2.1 NORMATIVE STANDARDS.......................................................................................................................................9 2.2 MODE OF OPERATION DURING THE TEST.................................................................................................................10 2.3 TEST PERIPHERALS USED ..................................................................................................................................... 10 2.4 RECORD OF CLIMATIC CONDITIONS ........................................................................................................................ 10 2.5 INSTRUMENT LIST .............................................................................................................................................. 11 2.6 MEASUREMENT UNCERTAINTY.............................................................................................................................12

EMISSION TEST ................................................................................................................................................... 13

3. MAINS/LOAD/CONTROL TERMINAL CONTINUOUS DISTURBANCE VOLTAGE.............................................. 13

3.1 TERMINAL VOLTAGE LIMITS FOR THE FREQUENCY RANGE 9KHZ TO 30MHZ .................................................................. 13 3.1.1 General limits......................................................................................................................................13 3.1.2 Limits for mains port of tools .............................................................................................................. 13
3.2 BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................... 14 3.3 TEST SETUP AND TEST PROCEDURE ....................................................................................................................... 15 3.4 TEST PROTOCOL ................................................................................................................................................ 16

4. MAINS TERMINAL DISCONTINUOUS DISTURBANCE VOLTAGE/CLICK ......................................................... 18

4.1 BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................... 18 4.2 TEST SETUP AND TEST PROCEDURE ....................................................................................................................... 18 4.3 TEST PROTOCOL ................................................................................................................................................ 19

5. CONTINUOUS DISTURBANCE POWER ........................................................................................................ 20

5.1 CONTINUOUS DISTURBANCE POWER LIMIT..............................................................................................................20 5.2 BLOCK DIAGRAM OF TEST SET UP .......................................................................................................................... 20 5.3 TEST PROCEDURE .............................................................................................................................................. 20 5.4 TEST PROTOCOL ................................................................................................................................................ 21

6. RADIATED EMISSION ................................................................................................................................. 23

6.1 LIMIT .............................................................................................................................................................. 23 6.2 BLOCK DIAGRAM AND TEST SET UP ........................................................................................................................ 23 6.3 TEST PROTOCOL ................................................................................................................................................ 24

7. HARMONICS .............................................................................................................................................. 26

7.1 BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................... 26 7.2 TEST SETUP AND TEST PROCEDURE ....................................................................................................................... 26 7.3 TEST PROTOCOL ................................................................................................................................................ 27

8. VOLTAGE FLUCTUATIONS-FLICKER.............................................................................................................. 28

8.1 BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................... 28 8.2 TEST SETUP AND TEST PROCEDURE ....................................................................................................................... 28
8.2.1 Definition ............................................................................................................................................ 28 8.2.2 Test condition ...................................................................................................................................... 28 8.3 TEST PROTOCOL ................................................................................................................................................ 29

IMMUNITY TEST ................................................................................................................................................. 30

TTRF55014-01_V1 © 2018 Intertek

Page 3 of 52

Report No. 191000961SHA-001
9. ELECTROSTATIC DISCHARGE (ESD).............................................................................................................. 31
9.1 SEVERITY LEVEL AND PERFORMANCE CRITERION......................................................................................................31 9.1.1 Test level ............................................................................................................................................. 31 9.1.2 Performance Criterion.........................................................................................................................31
9.2 BLOCK DIAGRAM OF TEST SETUP .......................................................................................................................... 32 9.3 TEST SETUP AND TEST PROCEDURE ....................................................................................................................... 33 9.4 TEST PROTOCOL ................................................................................................................................................ 34
10. ELECTROMAGNETIC FIELD SUSCEPTIBILITY ................................................................................................ 35
10.1 SEVERITY LEVEL AND PERFORMANCE CRITERION ................................................................................................. 35 10.1.1 Test level ............................................................................................................................................. 35 10.1.2 Performance Criterion.........................................................................................................................35
10.2 BLOCK DIAGRAM OF TEST SETUP ...................................................................................................................... 36 10.3 TEST SETUP AND TEST PROCEDURE .................................................................................................................. 36 10.4 TEST PROTOCOL ........................................................................................................................................... 36
11. ELECTRIC FAST TRANSIENT/BURST IMMUNITY TEST .................................................................................. 37
11.1 SEVERITY LEVEL AND PERFORMANCE CRITERION ................................................................................................. 37 11.1.1 Test level ............................................................................................................................................. 37 11.1.2 Performance Criterion.........................................................................................................................37
11.2 BLOCK DIAGRAM OF TEST SETUP ..................................................................................................................... 38 11.2.1 Block Diagram for input a.c./d.c. power line ...................................................................................... 38 11.2.2 Block Diagram for output a.c./d.c. power line or signal/control lines ................................................ 39
11.3 TEST SETUP AND TEST PROCEDURE .................................................................................................................. 39 11.4 TEST PROTOCOL ........................................................................................................................................... 40
12. SURGE IMMUNITY TEST ............................................................................................................................. 41
12.1 SEVERITY LEVEL AND PERFORMANCE CRITERION ................................................................................................. 41 12.1.1 Test level ............................................................................................................................................. 41 12.1.2 Performance Criterion.........................................................................................................................41
12.2 BLOCK DIAGRAM OF TEST SETUP ..................................................................................................................... 42 12.3 TEST SETUP AND TEST PROCEDURE .................................................................................................................. 42 12.4 TEST PROTOCOL ........................................................................................................................................... 42
13. IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS ............................. 43
13.1 SEVERITY LEVEL AND PERFORMANCE CRITERION ................................................................................................. 43 13.1.1 Test level ............................................................................................................................................. 43 13.1.2 Performance Criterion.........................................................................................................................43
13.2 BLOCK DIAGRAM OF TEST SETUP ..................................................................................................................... 43 13.3 TEST SETUP AND TEST PROCEDURE .................................................................................................................. 44 13.4 TEST PROTOCOL ........................................................................................................................................... 45
14. VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TEST ............................... 46
14.1 SEVERITY LEVEL AND PERFORMANCE CRITERION ................................................................................................. 46 14.1.1 Test level ............................................................................................................................................. 46 14.1.2 Performance Criterion.........................................................................................................................46
14.2 BLOCK DIAGRAM OF TEST SETUP ...................................................................................................................... 47 14.3 TEST SETUP AND TEST PROCEDURE .................................................................................................................. 47 14.4 TEST PROTOCOL ........................................................................................................................................... 47
APPENDIX I: PHOTOGRAPH OF EQUIPMENT UNDER TEST................................................................................... 48

TTRF55014-01_V1 © 2018 Intertek

Page 4 of 52

Report No.

Version

191000961SHA-001 Rev. 01

Revision History
Description Initial issue of report

Report No. 191000961SHA-001
Issued Date November 27, 2019

TTRF55014-01_V1 © 2018 Intertek

Page 5 of 52

Report No. 191000961SHA-001

Measurement result summary

TEST ITEM
Mains terminal continuous disturbance voltage Mains terminal discontinuous disturbance voltage/click Continuous disturbance power Radiated Emission Harmonics Voltage fluctuation-Flicker Electrostatic Discharge (ESD) RF electromagnetic field susceptibility Electric Fast Transient /Burst (EFT/B) Surge Injected Current Voltage dips and interruption

TEST RESULT NA NA NA Pass NA NA Pass Pass NA NA NA NA

NOTE

Notes: 1. NA =Not Applicable 2. Determination of the test conclusion is based on IEC Guide 115 in consideration of measurement uncertainty. 3. Additions, Deviations and Exclusions from Standards: None.

TTRF55014-01_V1 © 2018 Intertek

Page 6 of 52

Report No. 191000961SHA-001

1. GENERAL INFORMATION

1.1 Description of Equipment Under Test (EUT)

Product name : Battery-powered Delta Sander

Type/Model : WX822, WX822.* (* = A to Z or 0-9 which means different package and/or accessories)
Description of EUT : The products covered in this report are hand-held motor-operated battery-powered sanders. All models are identical with each other except for the trade mark, package and/or accessories. One model was tested and the worst data is listed as representative.
Rating : 20Vd.c., n0:12000/min

Brand name : WORX

Mains lead : (un)shielded, (non)detachable

Data cable : None.

EUT type :

Table-top Floor standing

EUT is toy, defined

Category A

as

Category B

Category C

Category D

Category E

Sample received date : November 18, 2019

Sample Identification : 0191118-59-001 No.
Date of test : November 20, 2019

TTRF55014-01_V1 © 2018 Intertek

Page 7 of 52

Report No. 191000961SHA-001

1.2 Description of Test Facility Name : Intertek Testing Services Shanghai
Address : Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China

Telephone : 86 21 61278200 Telefax : 86 21 54262353

The test facility is : CNAS Accreditation Lab

recognized, certified, or Registration No. CNAS L0139

accredited by these organizations

FCC Accredited Lab Designation Number: CN1175

IC Registration Lab CAB identifier.: CN0051

VCCI Registration Lab Registration No.: R-14243, G-10845, C-14723, T-12252

A2LA Accreditation Lab Certificate Number: 3309.02

TTRF55014-01_V1 © 2018 Intertek

Page 8 of 52

Report No. 191000961SHA-001
2. TEST SPECIFICATIONS
2.1 Normative Standards
IEC 61000-4-2:2008: Electromagnetic Compatibility (EMC) ­ Part 4-2: testing and measurement techniques ­ electrostatic discharge immunity test IEC 61000-4-3:2006+A1:2007+A1:2010: Electromagnetic Compatibility (EMC) ­ Part 4-3: testing and measurement techniques ­ radiated, radio frequency, electromagnetic field immunity test IEC 61000-4-4:2012: Electromagnetic Compatibility (EMC) ­ Part 4-4: testing and measurement techniques ­ electric fast transient/burst immunity test IEC 61000-4-5:2014: Electromagnetic Compatibility (EMC) ­ Part 4-5: testing and measurement techniques ­ section 5: surge immunity test IEC 61000-4-6:2013: Electromagnetic Compatibility (EMC) ­ Part 4-6: testing and measurement techniques ­ section 6: immunity to conducted disturbance, induced by radio frequency field
IEC 61000-4-11:2004: Electromagnetic Compatibility (EMC) ­ Part 4-11: testing and measurement techniques ­voltage dips, short interruption and voltage variations immunity test
IEC 61000-4-22:2010, Electromagnetic compatibility (EMC) ­ Part 4-22: Testing and measurement techniques - Radiated emissions and immunity measurements in fully anechoic rooms (FARs)
Note: there are no magnetic sensitive components included in this EUT and magnetic field immunity test according to EN 61000-4-8 is therefore not required.

TTRF55014-01_V1 © 2018 Intertek

Page 9 of 52

Report No. 191000961SHA-001

2.2 Mode of operation during the test
Within this test report, EUT was tested under all available operation modes and tested under its rating voltage and frequency. Other voltage and frequency is specified if used.
2.3 Test Peripherals used

Item No 1

Description -

Band and Model -

S/No -

2.4 Record of climatic conditions

Test Item
Mains terminal continuous disturbance voltage
Mains terminal discontinuous disturbance voltage/click
Continuous disturbance power Radiated Emission Harmonics
Voltage fluctuation-Flicker Electrostatic Discharge (ESD)
RF electromagnetic field susceptibility
Electric Fast Transient /Burst (EFT/B) Surge
Injected Current Voltage dips and interruption

Temperature (°C) NA
NA
NA 24 NA NA 24
24
NA NA NA NA

Notes: NA =Not Applicable

Relative Humidity (%) NA
NA
NA 42 NA NA 42
42
NA NA NA NA

Pressure (Kpa) NA
NA
NA NA NA NA 101
NA
NA NA NA NA

TTRF55014-01_V1 © 2018 Intertek

Page 10 of 52

2.5 Instrument list

Radiated Emission

Used

Equipment

Test Receiver

Bilog Antenna

ESD

Used

Equipment

ESD generator

Radiated Immunity

Used

Equipment
Signal generator Power amplifier Log-period antenna
Field meter

Power sensor

Tet Site

Used

Equipment

Shielded room
Semi-anechoic chamber
Fully-anechoic chamber
Additional instrument

Used

Equipment
TheromHygrograph
TheromHygrograph
TheromHygrograph

Manufacturer R&S TESEQ
Manufacturer TESEQ
Manufacturer R&S AR AR AR
Keysight
Manufacturer Zhongyu Albatross project Albatross project
Manufacturer ZJ1-2A ZJ1-2A ZJ1-2A

Type ESIB 26 CBL 6112D
Type NSG 437
Type SMR 20 250W1000B AT 1080 FL17000 N1914A
Type -
Type S.M.I.F. S.M.I.F. S.M.I.F.

Report No. 191000961SHA-001

Internal no. EC 3045 EC 4206

Due date 2020-09-11 2019-12-10

Internal no. EC 4792-4

Due date 2020-03-27

Internal no. EC 3044-1 EC 5818-2 EC 3044-7 EC 5818-1 EC 5818-3

Due date 2020-01-13 2020-04-14 2020-03-04 2020-06-09 2020-04-14

Internal no. EC 2839 EC 3048
EC 3047

Due date 2020-01-13 2020-07-30
2020-07-30

Internal no. EC 2323 EC 5198 EC 3326

Due date 2019-12-23 2020-02-27 2020-04-07

TTRF55014-01_V1 © 2018 Intertek

Page 11 of 52

2.6 Measurement Uncertainty
Measurement
Conducted emission at mains ports
Continuous disturbance voltage at telecom ports
Continuous disturbance current at telecom ports
Mains terminal discontinuous disturbance voltage/click
Continuous disturbance power Radiated Emissions up to 1 GHz
Radiated Emissions above 1 GHz
Harmonic current emission Voltage fluctuations and flicker
ESD Radiated susceptibility EFT test at main terminal EFT test at signal/telecom terminal Surge test at main terminal Injected current test at main terminal Injected current test at unshielded signal
terminal Voltage dips and interruption

Report No. 191000961SHA-001

Frequency
9kHz ~ 150kHz 150kHz ~ 30MHz
150kHz ~ 30MHz
150kHz ~ 30MHz
-
30MHz ~ 300MHz 30MHz ~ 1GHz 1GHz ~ 6GHz 6GHz ~ 18GHz -
-
-

Expanded Uncertainty (k=2) (±) 3.52 dB 3.19 dB
3.64 dB
2.62 dB
3.76 dB
4.35 dB 4.90 dB 5.02 dB 5.28 dB 3.90% 10.34% 6.65% 2.38% 11.57% 11.62% 11.57% 1.88 dB
3.41 dB
6.05%

TTRF55014-01_V1 © 2018 Intertek

Page 12 of 52

Report No. 191000961SHA-001

Emission Test

3. Mains/Load/Control Terminal Continuous Disturbance Voltage

Test result:

NA

3.1 Terminal Voltage Limits for the frequency range 9kHz to 30MHz 3.1.1 General limits

Mains ports

Associated ports

Frequency range Disturbance voltage (MHz) Limits dB(V)

Disturbance voltage Limits dB(V)

Disturbance current Limits dB(V)

Quasi-peak Average Quasi-peak Average Quasi-peak Average

0.15 ~ 0.5 66 ~ 56 * 66 ~ 56 *

80

70

40 ~ 30 * 30 ~ 20 *

0.5 ~ 5.0 5.0 ~ 30

56

56

60

60

74 74

64 64

30

20

Notes:

1. * means the limit decreasing linearly with the logarithm of the frequency in the

range 0.15MHz to 0.5MHz.

2. If the quasi-peak measurements meet the average limit, the EUT shall be deemed to

meet both limits and the measurements using the average detector need not be carried

out.

3.1.2 Limits for mains port of tools

P  700 W

700 W < P  1 000 W

P > 1 000 W

Frequency range

Limits dB(V)

Limits dB(V)

Limits dB(V)

(MHz)

Quasi-peak Average Quasi-peak Average Quasi-peak Average

0.15-0.35

66-59* 59-49* 70-63* 63-53* 76-69* 69 ~ 59 *

0.35-5

59

49

63

53

69

59

5-30

64

54

68

58

74

64

Notes:

1. * means the limit decreasing linearly with the logarithm of the frequency in the

range 0.15MHz to 0.35MHz.

2. If the quasi-peak measurements meet the average limit, the EUT shall be deemed to

meet both limits and the measurements using the average detector need not be carried

out.

TTRF55014-01_V1 © 2018 Intertek

Page 13 of 52

3.2 Block Diagram of Test Setup At mains terminal
Wooden support

Report No. 191000961SHA-001

EUT Accessories

Supply voltage

A.M.N. 50 terminated

A.M.N.

For table top equipment, wooden support is 0.8m height table For floor standing equipment, wooden support is 0.1m height rack. At Associated ports

EMI receiver

Note:

: power line : signal line
: means the test setup while available

TTRF55014-01_V1 © 2018 Intertek

Page 14 of 52

Report No. 191000961SHA-001
3.3 Test Setup and Test Procedure
Measurement was performed in shielded room, and instruments used were according to clause 5.1 of EN 55014-1 if applicable. Detailed test procedure and arrangement was according to clause 5.2 of EN 55014-1. Measurement methods was according to clause 5.4 of EN 55014-1. Operation conditions of EUT was according to clause 6 of EN 55014-1. Frequency range 150kHz ­ 30MHz was checked and EMI receiver measurement bandwidth was set to 9kHz.

TTRF55014-01_V1 © 2018 Intertek

Page 15 of 52

Report No. 191000961SHA-001

3.4 Test Protocol

For Mains ports: Pass

L-Line

Frequency (MHz)

Quasi-peak

Corrected Reading (dBuV)

Limit (dBuV)

Margin (dB)

Corrected Reading (dBuV)

Average
Limit (dBuV)

Margin (dB)

Note: * means the emission level 20dB below the relevant limit.

N-Line

Frequency (MHz)

Quasi-peak

Corrected Reading (dBuV)

Limit (dBuV)

Margin (dB)

Corrected Reading (dBuV)

Average
Limit (dBuV)

Margin (dB)

Note: * means the emission level 20dB below the relevant limit.

Remark: 1. Correct Factor = LISN Factor + Cable Loss, the value was added to Original Receiver Reading by the software automatically.
2. Corrected Reading = Original Receiver Reading + Correct Factor 3. Margin = Limit - Corrected Reading 4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided.

Example: Assuming LISN Factor = 10.00dB, Cable Loss = 2.00dB, Original Receiver Reading = 10.00dBuV, Limit = 66.00dBuV.

TTRF55014-01_V1 © 2018 Intertek

Page 16 of 52

Then Correct Factor = 10.00 + 2.00 = 12.00dB; Corrected Reading = 10dBuV + 12.00dB = 22.00dBuV; Margin = 66.00dBuV ­ 22.00dBuV = 44.00dB.
For Associated ports: NA

Report No. 191000961SHA-001

Frequency (MHz)

Quasi-peak

Corrected Reading (dBuV)

Limit (dBuV)

Margin (dB)

Corrected Reading (dBuV)

Average
Limit (dBuV)

Margin (dB)

Note: * means the emission level 20dB below the relevant limit.
Remark: 1. Correct Factor = LISN Factor + Cable Loss, the value was added to Original Receiver Reading by the software automatically.
2. Corrected Reading = Original Receiver Reading + Correct Factor 3. Margin = Limit - Corrected Reading 4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided.
Example: Assuming LISN Factor = 10.00dB, Cable Loss = 2.00dB, Original Receiver Reading = 10.00dBuV, Limit = 66.00dBuV. Then Correct Factor = 10.00 + 2.00 = 12.00dB; Corrected Reading = 10dBuV + 12.00dB = 22.00dBuV; Margin = 66.00dBuV ­ 22.00dBuV = 44.00dB.

TTRF55014-01_V1 © 2018 Intertek

Page 17 of 52

Report No. 191000961SHA-001

4. Mains terminal discontinuous disturbance voltage/click

Test result:

NA

4.1 Block Diagram of Test Setup
EMI receiver with Time domain/Click meter

AMN

EUT

4.2 Test Setup and Test Procedure
Measurement was performed in shielded room, and instruments used were according to clause 5.1 of EN 55014-1 if applicable. Detailed test procedure and arrangement was according to clause 5.2 of EN 55014-1. Measurement methods was according to clause 5.4 of EN 55014-1. Operation conditions of EUT was according to clause 6 of EN 55014-1. 0.15MHz, 0.5MHz, 1.4MHz and 30MHz were spot checked, and upper quartile methods used during measurement. The final judgment of test result was according to figure 6 of EN 55014-1.

TTRF55014-01_V1 © 2018 Intertek

Page 18 of 52

Report No. 191000961SHA-001

4.3 Test Protocol

Frequency

(MHz)

0.15

0.5

1.4

30.0

Permitted limit

for continuous interference

66.0

56.0

56.0

60.0

(dBµV)

Counted click/switch operation number

Observed time (min)

Click duration (ms)

Click rate N

Factor

Permitted limits for clicks (dBµv)

Counted clicks exceeding the limits

Test result Any other descriptions:

TTRF55014-01_V1 © 2018 Intertek

Page 19 of 52

Report No. 191000961SHA-001

5. Continuous disturbance power

Test result:

NA

5.1 Continuous disturbance power limit

General

P  700 W

700 W < P  1 000 W

P > 1 000 W

Frequency range

Limits dB(pW)

Limits dB(pW)

Limits dB(pW)

Limits dB(pW)

(MHz)

Quasi-peak Average Quasi-peak Average Quasi-peak Average Quasi-peak Average

30-300

45-55* 35-45* 45-55* 35-45* 49-59* 39-49* 55-65* 45 55*

Notes:

1. * means the limit decreasing linearly with the logarithm of the frequency in the range 30MHz to 300MHz.

2. If the quasi-peak measurements meet the average limit, the EUT shall be deemed to meet both limits and

the measurements using the average detector need not be carried out.

5.2 Block diagram of test set up

Absorbing clamp

Absorber (ferrite rings)

6 dB attenuator

EMI test receiver

EUT
Current transforme r

Absorber (ferrite rings)

Transformer

Absorbing clamp moved over power cord to obtain max. reading on receiver

Mains

The transformer to provide a stable voltage to the EUT during the test

5.3 Test Procedure
Measurement was performed in shielded room, and instruments used were according to clause 5.1 of EN 55014-1 if applicable. Detailed test procedure and arrangement was according to clause 5.3 of EN 55014-1. Measurement methods was according to clause 5.4 of EN 55014-1. Operation conditions of EUT was according to clause 6 of EN 55014-1. Frequency range 30MHz ­ 300MHz was checked and EMI receiver measurement bandwidth was set to 120kHz.

TTRF55014-01_V1 © 2018 Intertek

Page 20 of 52

5.4 Test Protocol For Mains ports: Pass

Report No. 191000961SHA-001

Frequency (MHz)

Quasi-peak

Corrected Reading (dBpW)

Limit (dBpW)

Margin (dB)

Corrected Reading (dBpW)

Average
Limit (dBpW)

Margin (dB)

Note: * means the emission level 20dB below the relevant limit.
Remark: 1. Correct Factor = Clamp Factor + Cable Loss, the value was added to Original Receiver Reading by the software automatically.
2. Corrected Reading = Original Receiver Reading + Correct Factor 3. Margin = Limit - Corrected Reading 4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided.
Example: Assuming Clamp Factor = 10.00dB, Cable Loss = 2.00dB, Original Receiver Reading = 10.00dBpW, Limit = 66.00dBpW. Then Correct Factor = 10.00 + 2.00 = 12.00dB; Corrected Reading = 10dBpW + 12.00dB = 22.00dBpW; Margin = 66.00dBpW ­ 22.00dBpW = 44.00dB.

TTRF55014-01_V1 © 2018 Intertek

Page 21 of 52

For Associated ports: NA

Report No. 191000961SHA-001

Frequency (MHz)

Quasi-peak

Corrected Reading (dBpW)

Limit (dBpW)

Margin (dB)

Corrected Reading (dBpW)

Average
Limit (dBpW)

Margin (dB)

Note: * means the emission level 20dB below the relevant limit.
Remark: 1. Correct Factor = Clamp Factor + Cable Loss, the value was added to Original Receiver Reading by the software automatically.
2. Corrected Reading = Original Receiver Reading + Correct Factor 3. Margin = Limit - Corrected Reading 4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided.
Example: Assuming Clamp Factor = 10.00dB, Cable Loss = 2.00dB, Original Receiver Reading = 10.00dBpW, Limit = 66.00dBpW. Then Correct Factor = 10.00 + 2.00 = 12.00dB; Corrected Reading = 10dBpW + 12.00dB = 22.00dBpW; Margin = 66.00dBpW ­ 22.00dBpW = 44.00dB.

TTRF55014-01_V1 © 2018 Intertek

Page 22 of 52

Report No. 191000961SHA-001

6. Radiated emission

Test result:

PASS

As for in the disturbance power test all emission readings from the EUT are lower than the

applicable limits (Table 7) reduced by the margin (Table 8) and the maximum clock frequency is less

than 30MHz, the EUT is deemed to comply with the Radiated Emission requirement without test.

6.1 Limit

Radiated emission limit from frequency range 30MHz ­ 1000MHz

Frequency (MHz)

Permitted limit in dBV/m

Permitted limit in dBV/m

(Quasi-peak)

(Quasi-peak)

of Measurement Distance

of Measurement Distance

3m

10m

30 ~ 230

40

30

230 ~ 300

47

37

Notes:

1. For the measurement distance other than 3m and 10m, the limit is varied according to

20dB/10 decades.

2. The gray rows are selected items.

6.2 Block diagram and test set up

Antenna mast

EUT Turn Table

Test receiver AE
The measurement was applied in a semi-anechoic chamber. Operation conditions of EUT was according to clause 6 of EN 55014-1. Measurement was performed according to clause 10 of CISPR 32. Setting of EUT is according to clause 5.3.4.3 of EN 55014-1. The bandwidth setting on test receiver was 120kHz. The frequency range from 30MHz to 300MHz was checked.

TTRF55014-01_V1 © 2018 Intertek

Page 23 of 52

6.3 Test Protocol

Horizontal

Report No. 191000961SHA-001

Vertical

TTRF55014-01_V1 © 2018 Intertek

Page 24 of 52

Report No. 191000961SHA-001

Polarization

Frequency

Emission level

(MHz)

(dBV/m)

224.39

34.60

Horizontal

663.71 784.23

41.90 42.38

908.64

41.50

168.02

31.90

Vertical

224.39 675.37

36.51 37.60

965.01

35.20

*means the margin larger than 10 dBV/m.

Limits (dBV/m)
40.0 47.0 47.0 47.0 40.0 40.0 47.0 47.0

Margin (dBV/m)
5.40 5.10 4.62 5.50 8.10 3.49 9.40 11.80

Remark: 1. Correct Factor = Antenna Factor + Cable Loss (+ Amplifier, for higher than 1GHz), the value was added to Original Receiver Reading by the software automatically.
2. Corrected Reading = Original Receiver Reading + Correct Factor 3. Margin = Limit - Corrected Reading 4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided.

Example: Assuming Antenna Factor = 30.20dB/m, Cable Loss = 2.00dB, Gain of Preamplifier = 32.00dB, Original Receiver Reading = 10.00dBuV, Limit = 40.00dBuV/m. Then Correct Factor = 30.20 + 2.00 ­ 32.00 = 0.20dB/m; Corrected Reading = 10dBuV + 0.20dB/m = 10.20dBuV/m; Margin = 40.00dBuV/m - 10.20dBuV/m = 29.80dB.

TTRF55014-01_V1 © 2018 Intertek

Page 25 of 52

Report No. 191000961SHA-001

7. Harmonics

Test result:

NA

7.1 Block Diagram of Test Setup

Harmonic & flicker test system

EUT

AE

7.2 Test Setup and Test Procedure
Harmonics of the fundamental current were measured up to 40 order harmonics using a digital power meter with an analogue output and frequency analyser which was integrated in the harmonic & flicker test system. The measurements were carried out under steady conditions.
Measuring instrumentation according to IEC 61000-4-7:2002+A1:2008
This product is not defined as lighting equipment, and has rated power less than 75W, therefore, no limit apply according to EN 61000-3-2
The EUT is kitchen machines as listed in the scope of IEC 60335-2-14, therefore, is deemed to conform to the harmonic current limits of this standard without further testing.

TTRF55014-01_V1 © 2018 Intertek

Page 26 of 52

7.3 Test Protocol

Report No. 191000961SHA-001

TTRF55014-01_V1 © 2018 Intertek

Page 27 of 52

8. Voltage Fluctuations-Flicker

Test result:

NA

8.1 Block Diagram of Test Setup

Harmonic & flicker test

system

EUT

Report No. 191000961SHA-001 AE

8.2 Test Setup and Test Procedure 8.2.1 Definition

Flicker: impression of unsteadiness of visual sensation induced by a light stimulus whose luminance or spectral distribution fluctuates with time.

Pst:

Short-term flicker severity.

Plt:

long-term flicker severity.

dc:

maximum steady state voltage change during an observation period.

dmax: maximum absolute voltage change during an observation period.

d(t): time function of the relative r.m.s. voltage change evaluated as a single value for each successive half period between zero-crossings of the source voltage, except during time interval in which the voltage is a steady-state condition for at least 1s.

8.2.2 Test condition

The EUT was set to produce the most unfavorable sequence of voltage changes.

TTRF55014-01_V1 © 2018 Intertek

Page 28 of 52

Report No. 191000961SHA-001
8.3 Test Protocol
The tested object operated under the operating condition specified in EN 61000-3-3 The following limits apply
- the value of Pst shall not be greater than 1,0. - the value of Plt shall not be greater than 0,65. - Tmax, the accumulated time value of d(t) with a deviation exceeding 3,3 % during
a single voltage change at the EUT terminals, shall not exceed 500 ms. - the maximum relative steady-state voltage change, dc, shall not exceed 3,3 %. - the maximum relative voltage change dmax, shall not exceed:
4% without additional conditions. 6 % for equipment which is: ­ switched manually, or ­ switched automatically more frequently than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds), or manual restart, after a power supply interruption. 7 % for equipment which is: ­ attended whilst in use (for example: hair dryers, vacuum cleaners, kitchen equipment such as mixers, garden equipment such as lawn mowers, portable tools such as electric drills), or ­ switched on automatically, or is intended to be switched on manually, no more than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds) or manual restart, after a power supply interruption. for manual switch, dmax is measured in accordance with Annex B of standard, average dmax is calculated from 24 times measurement. The rate power of the EUT is no greater than 75W, which is unlikely to produce significant voltage fluctuations or flicker by technical analysis and evaluation. So it is deemed to fulfil the requirements without testing.

TTRF55014-01_V1 © 2018 Intertek

Page 29 of 52

Report No. 191000961SHA-001
Immunity Test
Performance criteria
The performance criteria are based on the general criteria of the standard and derived from the product specification Criterion A: Normal Performance within limits specified by the manufacturer, request or purchaser. Criterion B: Continue to operate as intended after the test. No degradation of performance or loss of function. During the test degradation of performance is allowed, however no change of actual operating state or stored date. Criterion C: Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls.
Categories of apparatus Category I (fulfill the relevant immunity requirements without testing) Category II (Shall fulfill the tests: ESD, EFT, Inject current, Surge, Dips) Category III (Shall fulfill the tests: ESD, EM fields*) Category IV (Shall fulfill the tests: ESD, EFT, Inject current, Surge, Dips, EM fields)
Note: *only applicable to the ride on toys operating with electronic devices.

TTRF55014-01_V1 © 2018 Intertek

Page 30 of 52

Report No. 191000961SHA-001

9. Electrostatic Discharge (ESD)

Test result:

PASS

9.1 Severity Level and Performance Criterion

9.1.1 Test level

1a ­ Contact discharge

1b ­ Air discharge

Level 1

Test voltage kV 2

Level 1

Test voltage kV 2

2

4

2

4

3

6

3

8

4

8

4

15

X

Special

X

Special

Notes: 1."X" is an open level. The level has to be specified in the dedicated equipment specification. If
higher voltages than those shown are specified, special test equipment may be needed. 2. The gray rows were the selected test level.

9.1.2 Performance Criterion

Performance criterion: B

TTRF55014-01_V1 © 2018 Intertek

Page 31 of 52

9.2 Block Diagram of Test Setup For table-top equipment

ESD simulator

ESD gun

EUT & AE

Report No. 191000961SHA-001
VCP Insulate Support

HCP
Wooden
support
GRP
Note: HCP means Horizontal Coupling Plane VCP means Vertical Coupling Plane GRP means Ground Reference Plane Wooden support is a 0.8m height table
For floor standing equipment
VCP

ESD simulator

ESD gun

EUT &AE

Wooden support

470k Resistor
470k Resistor

GRP
Note: VCP means Vertical Coupling Plane GRP means Ground Reference Plane Wooden support is a 0.1m height rack

TTRF55014-01_V1 © 2018 Intertek

Page 32 of 52

Report No. 191000961SHA-001
9.3 Test Setup and Test Procedure
Measurement was performed in shielded room. Measurement and setting of EUT was applied according to IEC 61000-4-2 Clasuse 7. The test method and equipment was specified by IEC 61000-4-2 with the modifications by EN 55014-2 clause 5.1.

TTRF55014-01_V1 © 2018 Intertek

Page 33 of 52

Report No. 191000961SHA-001

9.4 Test Protocol

Direct discharges were applied at the following selected points:

Test point # A B C D E

Test level [kV] 2/4 2/4 2/4/8 2/4/8 2/4/8

Air/ Contact Contact Contact
Air Air Air

Polarity (+/-) +/+/+/+/+/-

Pass/Fail/NA

Comment

Pass

All touchable screws of enclosure

Pass

Accessible metal parts of the EUT

Pass

Air gap of the switch, button

Pass

The air in-taking opening

Pass

Slots around the EUT

Indirect contact discharges were applied to the VCP and the HCP at the following selected points:

For table top equipment

Point HCP f HCP b HCP r HCP l VCP f VCP b VCP r VCP l

Description 0,1m from the front of the EUT 0,1m from the back of the EUT 0,1m from the right side of the EUT 0,1m from the left side of the EUT 0,1m from the front of the EUT 0,1m from the back of the EUT 0,1m from the right of the EUT 0,1m from the left of the EUT

Point Edge of centre, corner on HCP Edge of centre, corner on HCP Edge of centre, corner on HCP Edge of centre, corner on HCP Edge of centre, corner on VCP Edge of centre, corner on VCP Edge of centre, corner on VCP Edge of centre, corner on VCP

Pass/Fail/NA Pass Pass Pass Pass Pass Pass Pass Pass

For floor standing equipment

Point VCP f VCP b VCP r VCP l

Description 0,1m from the front of the EUT 0,1m from the back of the EUT 0,1m from the right of the EUT 0,1m from the left of the EUT

Point Edge of centre, corner on VCP Edge of centre, corner on VCP Edge of centre, corner on VCP Edge of centre, corner on VCP

Pass/Fail/NA NA NA NA NA

Observation: All the functions were operated as normal during and after test. Conclusion: The EUT met the requirements of Performance Criterion B.

TTRF55014-01_V1 © 2018 Intertek

Page 34 of 52

Report No. 191000961SHA-001

10. Electromagnetic field susceptibility

Test result:

Pass

10.1 Severity Level and Performance Criterion

10.1.1 Test level

Level

Test field strength V/m

1

1

2

3

3

10

X

Special

Notes:

1. X is an open test level. This level may be given in the product specification.

2. The gray row is the selected test level.

10.1.2 Performance Criterion

Performance criterion: A

TTRF55014-01_V1 © 2018 Intertek

Page 35 of 52

10.2 Block diagram of test setup

Report No. 191000961SHA-001

Antenna mast

Field probe EUT Table

Amplifier

Signal generator

Power meter Field monitor

AE Optical fiber

10.3 Test Setup and Test Procedure

Measurement was performed in full-anechoic chamber. Measurement and setting of EUT was applied according to IEC 61000-4-3 clause 7. The test method and equipment was specified by IEC 61000-4-3 with additions and modifications by EN 55014-2 clause 5.5.

10.4 Test Protocol

Test Frequency Polarization Test level

no.: (MHz)

V/m

Modulation

Exposed Pass/Fail/NA Commen

location

t

1 80-1000

H & V

3

1kHz, 80%, SW, AM, 1% step size

All sides

Pass

-

Observation: All the functions were operated as normal during and after test. Conclusion: The EUT met the requirements of Performance Criterion A.

TTRF55014-01_V1 © 2018 Intertek

Page 36 of 52

Report No. 191000961SHA-001

11. Electric Fast Transient/Burst Immunity Test

Test result:

NA

11.1 Severity Level and Performance Criterion

11.1.1 Test level

Open circuit output test voltage (±10%) and repetition rate of the impulses (±20%)

Input and output a.c. power ports Input and output d.c. power ports

Level

Signal lines and control lines ports

Voltage peak Repetition rate Voltage peak Repetition rate

kV

kHz

kV

kHz

1

0.5

5

0.25

5

2

1

5

0.5

5

3

2

5

1

5

4

4

5

2

5

X

Special

Special

Special

Special

Notes : 1. "X" is an open level. The level has to be specified in the dedicated equipment
specification. 2. The gray rows were the selected test level.

11.1.2 Performance Criterion

Performance criterion B

TTRF55014-01_V1 © 2018 Intertek

Page 37 of 52

11.2 Block Diagram of Test Setup 11.2.1 Block Diagram for input a.c./d.c. power line
For table-top equipment

Report No. 191000961SHA-001

Grounding cable
GRP

EFT/B Generator

EUT & AE

0.1m high Insulating support

1.1.1.1.1.1.1.1

Grounding

GRP

cable

For floor standing equipment

Grounding cable

EFT/B Generator

EUT & AE

0.1m high Insulating support

GRP

TTRF55014-01_V1 © 2018 Intertek

Page 38 of 52

Report No. 191000961SHA-001
11.2.2 Block Diagram for output a.c./d.c. power line or signal/control lines For table-top equipment

Grounding cable
GRP EFT/B Generator

EUT

AE

Clamp

Grounding cable

0.1m high
Insulating support

GRP
For floor standing equipment
Grounding cable

EFT/B Generator

EUT

AE

Clamp

GRP 0.1m high Insulating support
11.3 Test Setup and Test Procedure
Measurement was performed in shielded room. Measurement and setting of EUT was applied according to IEC 61000-4-4 clause 7. The test method and equipment was specified by IEC 61000-4-4 with additions and modifications by EN 55014-2 clause 5.2.

TTRF55014-01_V1 © 2018 Intertek

Page 39 of 52

11.4 Test Protocol

Test

Level

No.

[kV]

1

1

2

0.5

3

0.5

Observation: Conclusion:

Report No. 191000961SHA-001

Polarity +/+/+/+/-

Repetition rate kHz 5 5 5

Line for test

Pass/Fail/NA

a.c. power ports

NA

d.c. power ports

NA

Signal lines and

NA

control lines

TTRF55014-01_V1 © 2018 Intertek

Page 40 of 52

Report No. 191000961SHA-001

12. Surge Immunity Test

Test result:

NA

12.1 Severity Level and Performance Criterion

12.1.1 Test level

Level 1

Open-circuit test voltage ±10% kV 0.5

2

1.0

3

2.0

4

4.0

X*

Special

Notes: 1."X" is an open class. This level can be specified in the product Specification 2. The gray rows are the selected level.

12.1.2 Performance Criterion

Performance criterion B

TTRF55014-01_V1 © 2018 Intertek

Page 41 of 52

12.2 Block Diagram of Test Setup
Surge Generator

Report No. 191000961SHA-001

EUT & AE

Insulating support

GRP

12.3 Test Setup and Test Procedure

Measurement was performed in shielded room. Measurement and setting of EUT was applied according to IEC 61000-4-5 clause 7. The test method and equipment was specified by IEC 61000-4-5 with modifications by EN 55014-2 clause 5.6.

12.4 Test Protocol

Test

Level

Polarity Angle

Line for test

Pass/Fail/NA

No.

[kV]

+/-

1

1

+

900 a.c. Mains (line to earth)

2

1

-

2700 a.c. Mains (line to earth)

3

1

+

900

a.c. Mains (line to line)

4

1

-

2700 a.c. Mains (line to line)

5

2

+

900 a.c. Mains (line to earth)

6

2

-

2700 a.c. Mains (line to earth)

Observation: Conclusion:

TTRF55014-01_V1 © 2018 Intertek

Page 42 of 52

Report No. 191000961SHA-001

13. Immunity to Conducted Disturbances, Induced by Radio-frequency Fields

Test result:

NA

13.1 Severity Level and Performance Criterion

13.1.1 Test level

Level 1

Frequency range 150kHz ­ 80MHz

Voltage level (e.m.f.)

U0 [dB(uV)]

U0 (V)

120

1

2

130

3

3

140

10

X

Special

Special

Notes: 1. "X" is an open level. 2. The gray row is the selected test level.
13.1.2 Performance Criterion

Performance criterion: A

13.2 Block Diagram of Test Setup

13.2.1 Block Diagram for a.c./d.c input power line

Block Diagram for a.c./d.c input power line

a.c./d.c. power supply

GRP

RF Generator

with amplifier

6dB

CDN

Attenuator

EUT power input line EUT

3cm high Insulating support

10cm high Insulating support

TTRF55014-01_V1 © 2018 Intertek

Page 43 of 52

Report No. 191000961SHA-001
13.2.2 Block Diagram for output a.c./d.c. power line or signal/control lines Unshielded line

GRP

RF Generator

with amplifier

6dB

EUT

Attenuator

Unshielded line
AE Clamp

3cm high insulating support
10cm high insulating support

Shielded line

GRP RF Generator with amplifier

6dB Attenuator

100

Shielded line

EUT

Ferrite

AE

ring core

3cm high insulating support
10cm high insulating support

13.3 Test Setup and Test Procedure
Measurement was performed in shielded room. Measurement and setting of EUT was applied according to IEC 61000-4-6 clause 7. The test method and equipment was specified by IEC 61000-4-6 with additions and modifications by EN 55014-2 clause 5.3, 5.4.

TTRF55014-01_V1 © 2018 Intertek

Page 44 of 52

Report No. 191000961SHA-001

13.4 Test Protocol

EUT is not required for electromagnetic susceptibility

Test Frequency

Level

Modulation

No.

(MHz)

V (r.m.s.)

1

0.15~230

3

1kHz, 80%, SW,

AM,

1% step size

2

0.15~230

1

1kHz, 80%, SW,

AM,

1% step size

3

0.15~230

1

1kHz, 80%, SW,

AM,

1% step size

For EUT test Electromagnetic field susceptibility

Test Frequency

Level

Modulation

No.

(MHz)

V (r.m.s.)

1

0.15~80

3

1kHz, 80%, SW,

AM,

1% step size

2

0.15~80

1

1kHz, 80%, SW,

AM,

1% step size

3

0.15~80

1

1kHz, 80%, SW,

AM,

1% step size

Injected point a.c. power ports
d.c. power ports
signal lines and control lines
Injected point a.c. power ports
d.c. power ports
signal lines and control lines

Pass/Fail/NA -
Pass/Fail/NA NA -

Observation: Conclusion:

TTRF55014-01_V1 © 2018 Intertek

Page 45 of 52

Report No. 191000961SHA-001

14. Voltage Dips, Short Interruptions and Voltage Variations Immunity Test

Test result:

NA

14.1 Severity Level and Performance Criterion

14.1.1 Test level

Test level

Voltage dip and short

Duration

interruptions

(in period)

% UT

% UT

50Hz

60Hz

0

100

0.5 cycle

0.5 cycle

40

60

10 cycles

12 cycles

70

30

25 cycles

30 cycles

Notes:

1."*" for 0.5 period, the test shall be made in positive and negative polarity, i.e.

starting at 0 and 180, respectively.

2. "**" means "x" is an open duration. This duration can be given in the product

specification. Utilities in Europe have measured dips and short interruptions of duration between

½ a period and 3000 periods, but duration less than 50 periods are most common.

3. If the EUT is tested for voltage dips of 100%, it is generally unnecessary to test for other

levels for the same durations. However, for some cases (safeguard systems or electro-mechanical

devices) it is not true. The product specification or product committee shall give an indication of

the applicability of this note.

4. The gray rows are selected test level.

14.1.2 Performance Criterion

Performance criterion: C

TTRF55014-01_V1 © 2018 Intertek

Page 46 of 52

14.2 Block diagram of test setup

Report No. 191000961SHA-001

Voltage Dips Generator

EUT & AE
1.1.1.1.1.1.1.2 G

Insulating support

GRP

14.3 Test Setup and Test Procedure

Measurement was performed in shielded room. Measurement and setting of EUT was applied according to IEC 61000-4-11 clause 7. The test method and equipment was specified by IEC 61000-4-11 with additions and modifications by EN 55014-2 clause 5.7.

14.4 Test Protocol

Test % UT Voltage dip and short

no.

interruptions

% UT

1

70

30%

2

40

60%

3

0

100% pos half cycle

4

0

100% neg half cycle

Duration (in periods)
25 cycles at 50Hz 30 cycles at 60Hz 10 cycles at 50Hz 12 cycles at 60Hz 0.5 cycle at 50Hz 0.5 cycle at 60Hz 0.5 cycle at 50Hz 0.5 cycle at 60Hz

Pass/Fail/NA
NA NA NA NA NA NA NA NA

Observation: Conclusion:

TTRF55014-01_V1 © 2018 Intertek

Page 47 of 52

Appendix I: Photograph of equipment under test

Report No. 191000961SHA-001

Photo 1 (Outer appearance)

Photo 2 (Outer appearance)

TTRF55014-01_V1 © 2018 Intertek

Page 48 of 52

Report No. 191000961SHA-001

Photo 3 (Outer appearance)

Photo 4 (Outer appearance)

TTRF55014-01_V1 © 2018 Intertek

Page 49 of 52

Report No. 191000961SHA-001

Photo 5 (Switch Knob)

Photo 6 (inner view)

TTRF55014-01_V1 © 2018 Intertek

Page 50 of 52

Report No. 191000961SHA-001

Photo 7 (motor)

Photo 8 (PCB in tool)

TTRF55014-01_V1 © 2018 Intertek

Page 51 of 52

Report No. 191000961SHA-001
Photo 9 (switch) ***END of the report***

TTRF55014-01_V1 © 2018 Intertek

Page 52 of 52

Test Verification of Conformity

Verification Number: 2104033302SHA-V1

On the basis of the referenced test report(s), sample(s) tested of the below product have been found to comply with the standards harmonized with the directives listed on this verification at the time the tests were carried out. Other standards and Directives may be relevant to the product. This verification is part of the full test report(s) and should be read in conjunction with it <them>. This verification replaces previous verification dated: 26 Nov, 2019: 191000962SHA-V1

Once compliance with all product relevant

mark directives are verified, including any relevant e.g. risk

assessment and production control, the manufacturer may indicate compliance by signing a Declaration of

Conformity themselves and applying the mark to products identical to the tested sample(s).

Applicant Name & Address:
Manufacturing Site Name & Address: Product Description: Ratings & Principle Characteristics: Models/Type References: Brand Name: Relevant Standards:
Verification Issuing Office Name & Address: Date of Tests: Test Report Number(s):

Positec Technology (China) Co., Ltd. 18, Dongwang Road, Suzhou Industrial Park, Jiangsu 215123, P.R.China CHANGZHOU STADARD ELECTRIC APPLIANCE CO.,LTD NO.29 The Chunqiu Road Minghuang Industrial Wujin Changzhou, P.R.China. Battery-powered Delta Sander
20Vd.c., n0:12000/min
WX822, WX822.* (* = A to Z or 0-9 which means different package and/or accessories) WORX EN 62841-1: 2015+AC: 15 EN 62841-2-4:2014 the machinery directive: 2006/42/EC Intertek Testing Services Shanghai Building No.86, 1198 Qinzhou Road (North), Shanghai 200233, China Aug 09, 2021 191000962SHA-001+A1, 191000962SHA-002+A1

Signature
Name: Jonny Jing Position: Operation Manager Date: Aug 09, 2021

This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

Intertek

Page 1 of 1

GFT-OP-11b (22-August-2019)


iLovePDF