OSCAL PowerMax 3600 Portable Power Station
Packing List
- PowerMax 3600
- User Manual
- AC Charging Cable
- Car Charging Cable
- Solar charging cable
Product Description
The OSCAL PowerMax 3600 is a portable power station. The following diagram illustrates its various ports and features:
Front View:
- 1. LED lights
- 2. LED on/off switch
- 3. LCD display
- 4. AC output (120V)
- 5. AC power button
- 6. DC output power button
- 7. Anderson output port (378W)
- 8. Main power button
- 9. Cigarette Lighter Port (120W)
- 10. WIFI/Bluetooth pairing button
- 11. USB-C 100W output ports (x2)
- 12. USB-A output port (12W)
- 13. USB-A fast charging output ports (x3, 18W per port)
- 14. USB output power button
- 15. DC5521 output ports (x2)
Rear/Side View:
- 16. Solar/Car charging input port
- 17. AC charging input port (1800W)
- 18. AC input overload protector
- 19. AC charge speed switch
- 20. Power Pack Connection Interface (for connecting additional battery packs, up to 3.6kWh each)
LCD Display Information
The LCD display provides real-time status and warnings:
- ? Bluetooth: Bluetooth connectivity status
- ? WIFI: Wi-Fi connectivity status
- ❄️ Low temperature warning
- ? High temperature warning
- ⚠️ Error code: Displays error codes
- ? Battery pack failure warning
- ☀️ Solar charging: Indicates solar charging status
- ⚡ DC output: Indicates DC output status
- ? USB output: Indicates USB output status
- ⚠️ OVERLOAD: Indicates output overload
- ? Charging state: Shows charging status
- ? Fan: Indicates fan operation
- ? Battery percentage: Displays remaining battery capacity
- ➡️ INPUT Watts: Shows input power
- ⬅️ OUTPUT Watts: Shows output power
- ? USB-A output: Specific USB-A output indicator
- ? Power Pack Access: Indicates connection to power packs
- ⚡ AC output: Indicates AC output status
- ⏳ Remaining charge/discharge time: Estimates time left
01 Power On/Off
To turn the device on or off:
- Press the AC ON/OFF button for approximately 3 seconds to turn AC output on or off.
- Press the DC ON/OFF button for approximately 3 seconds to turn DC output on or off.
- Press the USB ON/OFF button for approximately 3 seconds to turn USB output on or off.
- Press the Main Power Button for approximately 3 seconds to turn the entire unit on or off.
02 Power Pack Connection Charging
The PowerMax 3600 supports connecting up to fifteen additional power packs to increase battery capacity. The diagram shows three different connection methods.
03 Charging Your Devices
Connect various devices to the power station's output ports:
- AC Output: Connect appliances like rice cookers, kettles, vacuum cleaners, washing machines, RVs, and routers to the AC outlets. Use the AC ON/OFF button to control power.
- 12V Output: Connect devices requiring 12V power. Use the 12V ON/OFF button to control power.
- USB Output: Connect devices like laptops, cameras, and smartphones to the USB-A and USB-C ports. Use the USB ON/OFF button to control power.
04 Charging PowerMax 3600
The PowerMax 3600 can be recharged via multiple methods:
- Car charging: Connect to a car's 12V socket using the provided car charging cable.
- Grid charging: Connect to a wall outlet using the AC charging cable. The input port supports 100-120Vac, 15A.
- Solar charging: Connect solar panels to the solar charging input port (11-150Vdc, 15A Max).
The AC charge speed switch allows adjustment of the charging speed.
Specifications
Category | Details |
---|---|
General Info | |
Net Weight | Approximately 44.45kg |
Dimension (L × W × H) | 590×350×441mm (23.2×13.8×17.5in) |
Capacity | 3600Wh |
Wi-Fi | Frequency Range: 2412-2462MHz, Max Output Power: 0.05862W |
Bluetooth | Frequency Range: 2402-2480MHz, Max Output Power: 0.0006W |
Output Ports | |
AC (x4) | Pure sinewave, 3000W total, 100-120V ~ (50Hz/60Hz) |
USB-A (x1) | 12W Max |
USB-A Fast Charging (×3) | 18W Max per port, total 54W |
USB-C (×2) | 100W Max per port, total 200W |
Car Charger | 12V-10A, 120W Max |
DC5521 Output (×2) | 12V-3A, 36W |
Anderson Output | 12.6V-30A, 378W Max |
Input Ports | |
AC Charge | Fast charging 1800W, Slow charging 1200W |
AC Input Voltage | 100-120V~15A |
Solar Charger | 11-150V-15A Max, 1,600W Max |
Car Charger | 12V/24V-8A Max, 192W Max |
Battery Info | |
Cell Chemistry | LFP |
Cycle Life | 3,500 cycles to 80% + capacity |
Protection Type | Over Voltage Protection, Overload Protection, Over Temperature Protection, Short Circuit Protection, Low Temperature Protection, Low Voltage Protection, Overcurrent Protection |
Operating Temperature | |
Optimal Operating Temperature | 20°C~30°C (68°F~86°F) |
Discharging Temperature | -10°C~45°C (14°F~113°F) |
Charging Temperature | 0°C~45°C (32°F~113°F) |
Storage Temperature | -10°C~45°C (14°F~113°) |
Add-ons (sold separately) | |
Lithium battery charging package | Up to fifteen units, total capacity is 16 * 3.6kWh = 57.6kWh. Sold separately. |
solar panel | Supports solar charging, 11-150V/15A Max, 1600W Max. Sold separately. |
Safety Instructions
Usage
- Do not use the product near a heat source, such as a fire source or a heating furnace.
- Avoid contact with any liquid. Do not immerse the product in water or get it wet. Do not use the product in rain or humid environments.
- Do not use the product in an environment with strong static electricity/magnetic fields.
- Do not disassemble the product in any way or pierce the product with sharp objects.
- Avoid using wires or other metal objects that may result in a short circuit.
- Do not use unofficial components or accessories. Please visit official channels for replacements.
- Strictly follow the specified operating temperature. High temperatures may cause fire/explosion; low temperatures may reduce performance or cause shutdown.
- Do not stack heavy objects on the product.
- Do not forcibly lock the fan during use.
- Avoid impact, falls, or severe vibrations. In case of severe impact, turn off the power supply immediately. Ensure the product is well fastened during transportation.
- If accidentally dropped into water, place in a safe open area and stay away until dry. The dried product should not be used again and must be disposed of properly. Recommended fire extinguishers: water, sand, dry powder, CO2.
- Use a dry cloth to clean product ports.
- Rest the product on a flat surface to avoid falling. If severely damaged after falling, turn off immediately, place in an open area, and dispose of according to local laws.
- Keep out of reach of children and pets.
- Store the product in a dry and ventilated place.
- Use moisture barrier bags in wet environments to prevent soaking. If water is found inside, do not use or turn on again. Take anti-electric shock measures before touching. Place in a safe, waterproof area and contact Customer Service.
- This product is not recommended for powering medical emergency equipment related to personal safety (e.g., ventilators, ECMO). Consult doctors and manufacturers for restrictions. For general medical equipment, monitor power status.
- Power supply products generate electromagnetic fields that may affect medical implants (pacemakers, cochlear implants, hearing aids, defibrillators). Contact manufacturers for restrictions and ensure a safe distance.
- When connected to a refrigerator, power fluctuations may cause automatic shutdown. For refrigerators storing medicine/vaccines, set AC output to "Always on" in the app for continuous supply.
Disposal Guide
- If possible, fully discharge the battery before disposing it in a designated recycling bin. The product contains chemicals and must not be disposed of in ordinary trash. Follow local laws.
- If the battery cannot be fully discharged due to failure, do not dispose of it directly. Contact a professional battery recycling company.
- Dispose of over-discharged batteries that cannot be recharged.
Error Code and Handling
DTC | Exception | Abnormal recovery method |
---|---|---|
001 | Over Voltage Protection | Stop charging and let stand for a period of time, or automatically restore after discharge |
002 | Low Voltage Protection | Recovery after charging with mains power |
003 | Discharge current overload | Remove abnormal load and automatically recover after normal load |
004 | Charging current overload | Automatic recovery after disconnecting charging |
005 | Short circuit protection | Please contact after-sales |
006 | Battery collection disconnection | Please contact after-sales |
007 | Low temperature of battery charging | The battery temperature recovers automatically after it returns above 0°C |
008 | Battery charging high temperature | The battery recovers automatically after cooling down |
009 | Battery discharge low temperature | The battery automatically recovers when the temperature is higher than -20 °C |
010 | Battery discharge high temperature | The battery recovers automatically after cooling down |
013 | The total battery voltage is too high | Automatic recovery after stopping charging |
014 | The total battery voltage is too low | Automatic recovery after charging |
015 | MPPT failure | Please contact after-sales |
016 | Prohibit photovoltaic charging | The system automatically recovers after a period of delay |
018 | Battery failure | Automatic recovery after discharge |
UPS Functionality
The product supports UPS functionality. When connected to grid power via the AC Input Port, it can power devices through the AC Output Port. In case of a sudden blackout, it can automatically switch to battery power within 10ms.
Note: This basic UPS function does not support 0ms switching. Do not connect devices requiring 0ms UPS, such as data servers or workstations. Test compatibility before use. It is recommended to charge only one device at a time to avoid overload protection. OSCAL is not responsible for device failures or data losses due to improper use.
APP Connection
- Download Smart Life APP: Search for "Smart Life" on the App Store or Android app store and install it.
- Register and Log In: Select the appropriate version for your country, register, and log in to the Smart Life app.
- Initialize Bluetooth: Turn on the Bluetooth button on the device and press it for more than 5 seconds to initialize Bluetooth.
- Add Device: Open the Smart Life app and follow the prompts to add the OSCAL PowerMax 3600. The app interface shows device status, battery percentage, input/output power, and remaining time.
Disclaimer
Before use, please read the user manual thoroughly. Keep the manual for future reference. Improper handling may cause serious injury or product damage. By using the product, you accept all terms and conditions. The user is responsible for their actions. The company is not liable for losses due to failure to use the product as per the manual.
The company reserves the right to make final interpretations and changes to this document without notice. Visit the OSCAL official website for the latest product information.
FCC Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) it must not cause harmful interference, and (2) it must accept any interference received, including interference that may cause undesired operation. Changes not expressly approved by the responsible party may void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, designed to provide reasonable protection against harmful interference in residential installations. It generates, uses, and can radiate radio frequency energy and may cause interference to radio communications if not installed and used per instructions. No guarantee of no interference in a particular installation.
If interference occurs, try correcting it by:
- Reorienting or relocating the receiving antenna.
- Increasing the separation between the equipment and receiver.
- Connecting the equipment to a different circuit than the receiver.
- Consulting a dealer or experienced radio/TV technician.
To maintain compliance with FCC RF Exposure guidelines, install and operate with a minimum distance of 20cm between the radiator and your body. Use only the supplied antenna.