Lighting Solutions AE vs. AF light squares

The Galleon and Navion outdoor area luminaires from the McGraw-Edison, Lumark and Streetworks brands are now available with a newly upgraded light engine. The Galleon Wall Companion, XNV2 and XNV products will receive upgrades in the coming weeks. The new `AF' Light Square generation demonstrates Eaton's commitment to providing our customers with industry leading performance and value. Available lumen packages now exceed 68,000 lumens with efficacies eclipsing 130 lumens per watt. These improvements enable the replacement of a 1000W metal halide fixture with a 6-square LED fixture and a 750W metal halide fixture with a 4-square LED fixture -- both at over 60 percent energy savings.
The transition to the `AF' Light Square generation brings an incredible 16 percent lumen increase along with a 10 percent increase in efficacy at comparable square counts using the standard 1A drive current. In addition to the lumen and efficacy improvements, a new optional 1.2A drive current increases the maximum lumen output of the fixtures by more than 27 percent while still maintaining a 5 percent increase in efficacy. The `AF' Light Square generation will maintain the standard 1A drive current and transition the 700mA and 530mA options to 800mA and 600mA in order to provide a more balanced range of lumen packages.

Drive Current -1A
700mA 530mA

`AE' Light Square Lumen Output --
5,100-5,700 lumens 3,700-4,200 lumens 2,900-3,300 lumens

LPW --
92-102 10 0 -115 105-120

Drive Current 1. 2 A 1A
800mA 600mA

`AF' Light Square

Lumen Output

LPW

6,500-7,200 lumens

95-110

6,000-6,600 lumens

10 0 -115

4,800-5,300 lumens

110-125

3,900-4,300 lumens

115 -13 0 +

Lumen Increase +27% +16% +28% +31%

The tables below provide a simple reference in making the conversion to the new `AF' Light Square. Nominal lumens and `AE' square counts at each of the drive currents are compared to three scenarios using the new `AF' Light Square and drive currents:
· Maximum reduction in Light Squares (and cost) at the given lumen output · Maximum wattage reduction without increasing the square count · Maintaining the same lumen output (or higher) as the `AE' square count

`AE' - 1A Drive Current
Nominal Lumens
48,000-54,000 43,000-48,000 39,000-43,000 34,000-38,000 29,000-32,000 2 4 , 0 0 0 -2 7, 0 0 0 20,000-22,000 15 , 0 0 0 -17, 0 0 0 10 , 0 0 0 -11, 0 0 0
5,000-6,000
-continued

`AE' Light Squares

Number of Squares
10 9 8 7 6 5 4 3 2 1

`AE ` Drive Current
1A 1A 1A 1A 1A 1A 1A 1A 1A 1A

Fewer `AF' Light Squares (Lm within 6%)

Number of Squares

`AF ` Drive Current

8

1. 2 A

7

1. 2 A

6

1. 2 A

6

1A

5

1A

4

1A

3

1. 2 A

--

--

--

--

--

--

Wattage Reduction (Lm within 6%)

Number of Squares

`AF ` Drive Current

10

800mA

9

800mA

8

800mA

7

800mA

6

800mA

5

800mA

4

800mA

3

800mA

2

800mA

1

800mA

Maintain or Increase Lumens (Lm > `AE')

Number of Squares

`AF ` Drive Current

9

1A

8

1A

7

1A

7

1A

6

1A

5

1A

4

1A

3

1A

2

1A

1

1A

Lighting Solutions AE vs. AF light squares

`AE' - 700mA Drive Current
Nominal Lumens
35,000-39,000 32,000-35,000 29,000-32,000 25,000-28,000 21,000-24,000 18,000-20,000 14 , 0 0 0 -16 , 0 0 0 11, 0 0 0 -12 , 0 0 0
7, 0 0 0 - 8 , 0 0 0 3,500-4,500

`AE' Light Squares

Number of Squares
10 9 8 7 6 5 4 3 2 1

`AE ` Drive Current
700mA 700mA 700mA 700mA 700mA 700mA 700mA 700mA 700mA 700mA

Fewer `AF' Light Squares (Lm within 6%)

Number of Squares

`AF ` Drive Current

6

1A

5

1. 2 A

5

1A

4

1. 2 A

4

1A

3

1A

3

800mA

2

1A

--

--

--

--

Wattage Reduction (Lm within 6%)

Number of Squares

`AF ` Drive Current

9

600mA

8

600mA

6

800mA

7

600mA

6

600mA

5

600mA

4

600mA

3

600mA

2

600mA

1

600mA

Maintain or Increase Lumens (Lm > `AE')

Number of Squares

`AF ` Drive Current

8

800mA

7

800mA

7

800mA

6

800mA

5

800mA

4

800mA

4

800mA

3

600mA

2

600mA

1

600mA

`AE' - 530mA Drive Current
Nominal Lumens
28,000-31,000 25,000-28,000 23,000-25,000 20,000-22,000 17, 0 0 0 -19 , 0 0 0 14 , 0 0 0 -16 , 0 0 0 11, 0 0 0 -13 , 0 0 0 8 , 0 0 0 -10 , 0 0 0
6 , 0 0 0 -7, 0 0 0 3,000-3,500

`AE' Light Squares

Number of Squares
10 9 8 7 6 5 4 3 2 1

`AE ` Drive Current
530mA 530mA 530mA 530mA 530mA 530mA 530mA 530mA 530mA 530mA

Fewer `AF' Light Squares (Lm within 6%)

Number of Squares

`AF ` Drive Current

5

1A

4

1. 2 A

4

1A

3

1. 2 A

3

1A

3

800mA

2

1A

2

800mA

1

1A

--

--

Wattage Reduction (Lm within 6%)

Number of Squares

`AF ` Drive Current

7

600mA

7

600mA

6

600mA

5

600mA

4

600mA

4

600mA

3

600mA

--

--

--

--

--

--

Maintain or Increase Lumens (Lm > `AE')

Number of Squares

`AF ` Drive Current

8

600mA

7

600mA

5

800mA

5

800mA

4

800mA

4

600mA

3

800mA

2

800mA

1

1A

1

600mA

Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting
Canada Sales 5925 McLaughlin Road Mississauga, OntarioL5R 1B8 P: 905-501-3000 F: 905-501-3172

© 2016 Eaton All Rights Reserved Printed in USA Publication No. SB525024EN August 18, 2016

Eaton is a registered trademark.
All other trademarks are property of their respective owners.
Product availability, specifications, and compliances are subject to change without notice.


Adobe PDF Library 15.0