Digital Laser Infrared Thermometer Instruction Manual

Model No.: TP-30

Introduction

Thank you for purchasing the ThermoPro TP30 Infrared Thermometer. This easy-to-use device allows you to conveniently and accurately measure surface temperatures from a distance without the need for direct contact.

Features & Specifications

Function Diagram

The thermometer has several key components and indicators:

Operation

Surface Temperature Measurement

Note: The ThermoPro TP30 cannot measure the temperature of objects behind glass. Inaccuracy may also occur when exposed to steam, dust, or other contaminants in the air.

  1. Place the included AAA batteries into the Battery Compartment.
  2. Press the Measurement Trigger to activate the thermometer.
  3. Point the TP30 thermometer towards the surface you wish to measure.
  4. Press and hold the Measurement Trigger; the laser will activate for aiming guidance (laser is on by default).
  5. To take a continuous measurement, keep holding the Measurement Trigger while moving the TP30.
  6. Once the laser is pointed at the desired measurement point, release the Measurement Trigger. The Upper Display will show the last measured temperature.
  7. Press the Measurement Trigger again to take another measurement.

Emissivity

Emissivity is a material's efficiency in emitting thermal energy. Non-reflective surfaces have higher emissivity (closer to 1) than reflective surfaces (closer to 0). Inaccurate results may occur when measuring reflective surfaces like glass, polished wood, and granite.

To improve accuracy for reflective surfaces with low emissivity, place a strip of masking tape over the surface. Allow it to adjust to the surface temperature for approximately 30 minutes. Then, measure the taped section to eliminate inaccuracy.

The default emissivity of this device is 0.95, suitable for most organic materials and painted objects. Refer to the table below for improved accuracy with different objects:

ObjectsEmissivityObjectsEmissivityObjectsEmissivity
Aluminum0.30Iron0.70Frozen food0.90
Asbestos0.95Lead0.50Steel0.80
Asphalt0.95Limestone0.98Fabric0.94
Basalt0.70Oil0.94Glass0.85
Brass0.50Paint0.93Water0.93
Brick0.90Paper0.95Wood0.94
Carbon0.85Plastic0.95
Ceramics0.95Rubber0.95
Concrete0.95Sand0.90
Copper0.95Skin0.98
Sludge0.94Snow0.90

Distance-Spot Ratio

The ThermoPro TP30 measures surface temperature based on the distance-to-spot diameter ratio (D:S). As the distance increases, the measured surface area also increases. With a D:S ratio of 12:1, the measured surface area has a diameter of approximately 1/12 of the distance.

For accurate results, ensure the target's surface area is at least twice the spot diameter. Insufficient surface area leads to inaccurate readings. The recommended measurement distance is 7.87 inches (20cm) from the surface, creating a spot measurement area of 0.66 inches (1.67cm) in diameter.

Distance(D) to Spot (S) size: D:S=12:1

Replacing Batteries

The Low Battery Indication will appear on the Upper Display when the batteries are running low. Replace them immediately.

  1. Open the Battery Compartment and remove the used batteries. Dispose of them properly.
  2. Insert two new AAA batteries, ensuring correct polarity.
  3. Close the Battery Compartment.

Safe Use & Care

Disposal

Meaning of the "Dustbin" Symbol: ?️

This contributes to the recycling and reuse of electrical and electronic equipment. Information on disposal can be obtained from your local authority.

CAUTION: Batteries/rechargeable batteries must not be disposed of with household waste!

The following symbol indicates batteries/rechargeable batteries containing hazardous materials:

Limited One-Year Warranty

ThermoPro warrants this product to be free of defects in parts, materials, and workmanship for one year from the date of purchase. For repairs or servicing, contact Customer Service for instructions on packing and shipping the product to ThermoPro. This warranty grants specific legal rights, and you may have other rights that vary by state.

Customer Service

Models: TP-30, Digital Laser Infrared Thermometer

File Info : application/pdf, 8 Pages, 1.26MB

PDF preview unavailable. Download the PDF instead.

en-navod-pts-015 Corel PDF Engine Version 14.0.0.701 CorelDRAW

Related Documents

PreviewThermoPro TP-30 Digital Laser Infrared Thermometer Instruction Manual
Official instruction manual for the ThermoPro TP-30 Digital Laser Infrared Thermometer. This guide provides detailed information on features, specifications, operation, emissivity settings, distance-spot ratio, safety precautions, battery replacement, disposal, and warranty.
PreviewThermoPro TP-30W Digital Laser Infrared Thermometer Instruction Manual
This manual provides instructions for the ThermoPro TP-30W Digital Laser Infrared Thermometer, covering its features, specifications, operation, and safety guidelines. Learn how to accurately measure surface temperatures from a distance.
PreviewThermoPro TP-30 Digital Laser Infrared Thermometer Instruction Manual
This document provides comprehensive instructions for the ThermoPro TP-30 Digital Laser Infrared Thermometer, detailing its features, specifications, operation, safety guidelines, and warranty information.
PreviewThermoPro TP450 Dual Laser Infrared Thermometer Instruction Manual
Comprehensive instruction manual for the ThermoPro TP450 Dual Laser Infrared Thermometer, covering features, specifications, usage, emissivity, distance-spot ratio, safety, and warranty information.
PreviewThermoPro TP450 Dual Laser Infrared Thermometer Instruction Manual
Comprehensive instruction manual for the ThermoPro TP450 Dual Laser Infrared Thermometer, detailing its features, specifications, usage instructions, safety guidelines, and warranty information.
PreviewThermoPro TP410 Instant-Read Digital Infrared Thermometer User Manual
Comprehensive user manual for the ThermoPro TP410 instant-read digital infrared thermometer, detailing features, operation, specifications, safety, and warranty information for accurate non-contact surface temperature measurements.
PreviewThermoPro TP420 Two-in-One Infrared & Probe Thermometer User Manual
User guide for the ThermoPro TP420, a two-in-one instant infrared and probe thermometer. Learn about its features, specifications, how to measure temperatures, safety precautions, and warranty information.
PreviewThermoPro TP-15H Digital Instant Read Thermometer: User Manual & Features
Comprehensive instruction manual for the ThermoPro TP-15H digital instant read food thermometer. Learn about its features, specifications, how to use it for cooking, calibration, care, and warranty.