DG1221220-62768E-02 EN 301 489-1 V2.2.3&17 EMC Report

dg06131

SONOFF AIBridge CE EMC Test Report

iHost-DOC - SONOFF Official

PDF preview unavailable. Download the PDF instead.

SONOFF AIBridge CE EMC Test-Report
ETSI EN 301 489-1 V2.2.3 (2019-11) ETSI EN 301 489-17 V3.2.4 (2020-09)
TEST REPORT
For
Shenzhen Sonoff Technologies Co.,Ltd.
3F & 6F, Bldg A, No. 663, Bulong Rd, Shenzhen, Guangdong, China
Tested Model: AIBridge, AIBridge-26

Report Type: Original Report

Product Type: Smart Home Hub

Report Number: DG1221220-62768E-02

Report Date: 2023/2/20

Reviewed By:

Rocky Xiao RF Engineer

Test Laboratory:

Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

TABLE OF CONTENTS
DOCUMENT REVISION HISTORY......................................................................................................................... 4
GENERAL INFORMATION ...................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................................... 5 OBJECTIVE .................................................................................................................................................................. 5 TEST METHODOLOGY.................................................................................................................................................. 5 DECLARATIONS ........................................................................................................................................................... 5
SYSTEM TEST CONFIGURATION ......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION...................................................................................................................... 6 EQUIPMENT MODIFICATIONS....................................................................................................................................... 6 EUT EXERCISE SOFTWARE ......................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS.................................................................................................................... 6 SUPPORT CABLE LIST AND DETAILS............................................................................................................................ 6 BLOCK DIAGRAM OF TEST SETUP ............................................................................................................................... 7 TEST EQUIPMENT LIST ................................................................................................................................................ 8 ENVIRONMENTAL CONDITIONS ................................................................................................................................... 9
SUMMARY OF TEST RESULTS ............................................................................................................................ 10
1 - ENCLOSURE OF ANCILLARY EQUIPMENT MEASURED ON A STAND ALONE BASIS................... 11 MEASUREMENT UNCERTAINTY ................................................................................................................................. 11 TEST SYSTEM SETUP ................................................................................................................................................. 11 EMI TEST RECEIVER AND SPECTRUM ANALYZER SETUP .......................................................................................... 12 TEST PROCEDURE...................................................................................................................................................... 12 CORRECTED AMPLITUDE & MARGIN CALCULATION................................................................................................. 12 TEST DATA................................................................................................................................................................ 13
3 - AC MAINS POWER INPUT/OUTPUT PORTS ................................................................................................ 37 TEST SYSTEM SETUP ................................................................................................................................................. 37 EMI TEST RECEIVER SETUP ...................................................................................................................................... 37 TEST PROCEDURE...................................................................................................................................................... 37 CORRECTED AMPLITUDE & MARGIN CALCULATION................................................................................................. 37 TEST DATA................................................................................................................................................................ 38
5 - VOLTAGE FLUCTUATIONS AND FLICKER (AC MAINS INPUT PORT) ............................................... 50 TEST SYSTEM SETUP ................................................................................................................................................. 50 TEST STANDARD ....................................................................................................................................................... 50 TEST DATA................................................................................................................................................................ 51
6 - WIRED NETWORK PORTS............................................................................................................................... 53 TEST SYSTEM SETUP ................................................................................................................................................. 53 EMI TEST RECEIVER SETUP ...................................................................................................................................... 53 TEST PROCEDURE...................................................................................................................................................... 53 CORRECTED AMPLITUDE & MARGIN CALCULATION................................................................................................. 53 TEST DATA................................................................................................................................................................ 54
7 - RADIO FREQUENCY ELECTROMAGNETIC FIELDS (80 MHZ TO 6 000 MHZ) .................................. 62 TEST SYSTEM SETUP ................................................................................................................................................. 62 TEST LEVEL .............................................................................................................................................................. 62 TEST PROCEDURE...................................................................................................................................................... 63 TEST DATA................................................................................................................................................................ 63
8 - ELECTROSTATIC DISCHARGES.................................................................................................................... 64 TEST SYSTEM SETUP ................................................................................................................................................. 64 TEST LEVEL .............................................................................................................................................................. 64 TEST PROCEDURE...................................................................................................................................................... 64
Page 2 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

TEST DATA................................................................................................................................................................ 65
9 - FAST TRANSIENTS, COMMON MODE.......................................................................................................... 68
TEST SYSTEM SETUP ................................................................................................................................................. 68 TEST LEVEL .............................................................................................................................................................. 68 TEST PROCEDURE...................................................................................................................................................... 68 TEST DATA................................................................................................................................................................ 69
10 - RADIO FREQUENCY, COMMON MODE ..................................................................................................... 70
TEST SYSTEM SETUP ................................................................................................................................................. 70 TEST LEVEL .............................................................................................................................................................. 70 TEST PROCEDURE...................................................................................................................................................... 70 TEST DATA................................................................................................................................................................ 71
12 - VOLTAGE DIPS AND SHORT INTERRUPTIONS....................................................................................... 73
TEST SYSTEM SETUP ................................................................................................................................................. 73 TEST LEVEL AND PERFORMANCE CRITERION ............................................................................................................ 73 TEST PROCEDURE...................................................................................................................................................... 73 TEST DATA................................................................................................................................................................ 74
13 - SURGES ............................................................................................................................................................... 75
TEST SYSTEM SETUP ................................................................................................................................................. 75 TEST LEVEL .............................................................................................................................................................. 75 TEST PROCEDURE...................................................................................................................................................... 75 TEST DATA................................................................................................................................................................ 76
EXHIBITA - EUT PHOTOGRAPHS ....................................................................................................................... 77
CPU BOARD (RV1109) ............................................................................................................................................. 95
EXHIBITB - TEST SETUP PHOTOGRAPHS...................................................................................................... 100
RE ........................................................................................................................................................................... 100 CE_AC ................................................................................................................................................................... 102 CE_ISN .................................................................................................................................................................. 103 FLICKER .................................................................................................................................................................. 104 RS ........................................................................................................................................................................... 105 ESD ........................................................................................................................................................................ 106 EFT ......................................................................................................................................................................... 107 DIPS ........................................................................................................................................................................ 108 SURGE ..................................................................................................................................................................... 109 CS ........................................................................................................................................................................... 110

Page 3 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
DOCUMENT REVISION HISTORY

Revision Number 1.0

Report Number DG1221220-62768E-02

Report No.: DG1221220-62768E-02

Description of Revision Original Report

Date of Revision 2023/2/20

Page 4 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
GENERAL INFORMATION

Report No.: DG1221220-62768E-02

Product Description for Equipment under Test (EUT)

Product Name: Test Model:
Model Difference: Rated Input Voltage:
Serial Number:
EUT Received Date: EUT Received Status:

Smart Home Hub
AIBridge, AIBridge-26
Refer to Dos
5Vdc from USB Sample 1#_AIBridge(RV1109): 1W5O-1 Sample 2#_AIBridge-26(RV1126): 1WYF-2 2023/1/3
Good

Objective
This report is prepared on behalf of Shenzhen Sonoff Technologies Co.,Ltd. in accordance with ETSI EN 301 489-1 V2.2.3 (2019-11) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility;
ETSI EN 301 489-17 V3.2.4 (2020-09) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems;
The objective is to determine the compliance of EUT with: ETSI EN 301 489-1 V2.2.3 (2019-11), ETSI EN 301 489-17 V3.2.4 (2020-09).
Test Methodology
All measurements contained in this report were conducted with ETSI EN 301 489-1 V2.2.3 (2019-11) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility.
Declarations
BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol "". Customer model name, addresses, names, trademarks etc. are not considered data.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested.
This report cannot be reproduced except in full, without prior written approval of the Company.
Otherwise required by the applicant or Product Regulations, Decision Rule in this report did not consider the uncertainty.
The extended uncertainty given in this report is obtained by combining the standard uncertainty times the coverage factor K with the 95% confidence interval.
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.
This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk "".

Page 5 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
SYSTEM TEST CONFIGURATION

Report No.: DG1221220-62768E-02

Description of Test Configuration
The system was configured for testing in a typical fashion (as normally used by a typical user).
Test mode: M1: Operating &Wireless Linking M2:OperatingWired Linking&TF Card Working M3:Operating&Wired Linking&USB flash disk Working

Note: The chipset RTL8201F works as MCU, the wireless function not used.

Equipment Modifications
No modification was made to the EUT.
EUT Exercise Software
No software was used.

Support Equipment List and Details

Manufacturer SANDisk SanDisk / Lenovo ZIONCOM
R&S
Heiman

Description USB Flash Disk Micro TF Card
Antenna Laptop Wireless Router Wideband Radio Communication Tester Zigbee sensor

Model 16G UHS-I-16G
/ E480 MB-R210-00
CMW500
/

Serial Number BL201026115 B 9292DVDSV0XZ
/ PF-1QQYYP 19/06 EMZBWR21103004
149216
/

Support Cable List and Details

Cable Description RJ45 Cable RJ45 Cable
Antenna Cable

Shielding Cable Yes No Yes

Ferrite Core No No No

Length (m) 10 1 10

From Port EUT
Wireless Router CMW500

To Wireless Router Laptop
Antenna

Page 6 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
Block Diagram of Test Setup

LISN

Zigbee Sensor

Adapter 10cm EUT

Router Laptop

U Disk TF Card

Report No.: DG1221220-62768E-02

LISN 2

CMW500

Antenna

1.0 Meter

1.5 Meter

Non-Conductive Table 80 cm above Ground Plane

Page 7 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Test Equipment List

Manufacturer
R&S TESEQ
R&S MICRO-COAX
R&S
Sunol Sciences R&S
Unknown Unknown Unknown Sonoma
Farad
ETS-Lindgren Agilent Unknown AH Farad
E-Microwave
EVERFINE
EVERFINE
HP R&S
Werlatone
HP Agilent NARDA COM-POWER COM-POWER
EM TEST EM TEST EM TEST EM TEST
HAEFELY

Description

Model

Serial Number

Conducted emission

LISN

ENV 216

101614

ISN

T800

34379

EMI Test Receiver

ESCI

100035

Coaxial Cable

C-NJNJ-50

C-0200-01

Test Software

EMC32

Version 9.10.00

Radiated emissions below 1GHz

Antenna

JB3

A060611-1

EMI Test Receiver

ESR3

102453

Coaxial Cable

C-NJNJ-50

C-0075-01

Coaxial Cable

C-NJNJ-50

C-0400-01

Coaxial Cable

C-NJNJ-50

C-1400-01

Amplifier

310N

372193

Test Software

EZ-EMC

V1.1.4.2

Radiated emissions above 1GHz

Horn Antenna

3115

000 527 35

Spectrum Analyzer

E4440A

SG43360054

Coaxial Cable

C-SJSJ-50

C-0800-01

Preamplifier

PAM-0118

469

Test Software

EZ-EMC

V1.1.4.2

Band-stop Filters

OBSF-2400-2483. 5-S

OE01601525

Flicker

Harmonic & Flicker TEST ING Power Source
Harmonic & Flicker Measurement System

HFS-4000 HFM3000

P624486CD1411 122
P630850CD1411 115

CS

Signal Generator

8648A

3246A00831

Power Amplifier

15A250

12934

Dual Directional Coupler

C5091-10

113192

Power Meter 8482A Power sensor
Attenuator CDN CDN
Ultra Compact Generator Autotransformer CDN EFT Clamp
Electrostatic Discharge Simulator

HP EPM-441A

GB37481494

8482A

US37296108

769-6

2754

M325E

521064

T8E

581607

EFT & Surge & Dips

UCS 500N5

P1406130994

MV2616

P1450144859

CNV508 S1

311137

N/A

300886

ESD

ONYX

180786

RS

Calibration Date
2022/10/24 2022/10/24 2022/10/24
2022/9/5 N/A
2020/11/10 2022/10/24 2022/7/19 2022/7/19 2022/7/19 2022/7/18
N/A
2021/10/12 2022/7/15 2022/9/4 2022/10/13
N/A 2022/6/16
2022/4/1
2022/11/16
2022/10/24 N/A
2022/2/9 2023/2/9 2022/7/15 2022/11/18
N/A 2022/7/15 2022/7/15
2022/4/1 N/A
2022/11/22 2022/7/15
2022/10/27

Calibration Due Date
2023/10/23 2023/10/23 2023/10/23
2023/9/4 N/A
2023/11/9 2023/10/23 2023/7/18 2023/7/18 2023/7/18 2023/7/17
N/A
2024/10/11 2023/7/14 2023/9/3 2023/10/12
N/A 2023/6/15
2023/3/31
2023/11/15
2023/10/23 N/A
2023/2/8 2024/2/8 2023/7/14 2023/11/17
N/A 2023/7/14 2023/7/14
2023/3/31 N/A
2023/11/21 2023/7/14
2023/10/26

Page 8 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

AR AR HP AR AR PASTERNACK Agilent Agilent Agilent

Antenna Antenna Signal Generator Power Amplifier Power Amplifier Dual Directional Coupler EPM Series Power Meter E-Series Avg Power Sensor E-Series Avg Power Sensor

ATL80M1G ATT700M12G
8665B 500W1000C
60S1G6 PE2239-30
E4419B E9301A E9301A

Report No.: DG1221220-62768E-02

0351400 0349410 3438a00584 0353561 0348711
1711 MY45103907 MY41497625 MY41497628

N/A N/A 2022/11/18 N/A N/A 2022/7/15 2022/11/18 2022/7/15 2022/7/15

N/A N/A 2023/11/17 N/A N/A 2023/7/14 2023/11/17 2023/7/14 2023/7/14

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI).

Environmental Conditions

Test Item: Conducted emission

Temperature: Relative Humidity:
ATM Pressure: Tester:
Test Date:

17.3~20.3 36~38%
101.9~102.1kPa Walker Chen
2023/1/30~2023/2/16

Radiated emissions below 1GHz 19.5~20.1
52~63%
101.8~102.5kPa
Leo Yuan
2023/1/17~2023/2/15

Radiated emissions above 1GHz 17.1~21.2
37~44%
101.9~102.3kPa
Alan Xie
2023/1/29~2023/2/17

EMS & Flicker
18.1~23.2 40~51%
101.3~101.7kPa Lane Sun
2023/1/31~2023/2/14

Page 9 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
SUMMARY OF TEST RESULTS

Report No.: DG1221220-62768E-02

SN Rule and Clause

Description of Test

1

EN 301 489 Clause Enclosure of ancillary equipment measured on

8.2

a stand alone basis

2

EN 301 489 Clause 8.3

DC power input/output ports

3

EN 301 489 Clause 8.4

AC mains power input/output ports

4

EN 301 489 Clause Harmonic current emissions (AC mains input

8.5

port)

5

EN 301 489 Clause Voltage fluctuations and flicker (AC mains

8.6

input port)

6

EN 301 489 Clause 8.7

Wired network ports

7

EN 301 489 Clause Radio frequency electromagnetic fields (80

9.2

MHz to 6 000 MHz)

8

EN 301 489 Clause 9.3

Electrostatic discharges

9

EN 301 489 Clause 9.4

Fast transients, common mode

10

EN 301 489 Clause 9.5

Radio frequency, common mode

11

EN 301 489 Clause Transients and surges in the vehicular

9.6

environment

12

EN 301 489 Clause 9.7

Voltage dips and short interruptions

13

EN 301 489 Clause 9.8

Surges

Test Result
Compliant Not applicable
Compliant Not applicable
Compliant Compliant Compliant Compliant Compliant Compliant Not applicable Compliant Compliant

Note: Not Applicable: Please refer to Applicability overview tables in sections 7.1 and 7.2 of EN 301 489-1 requirements for Radio and ancillary equipment.

Page 10 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

1 - ENCLOSURE OF ANCILLARY EQUIPMENT MEASURED ON A STAND ALONE BASIS

Measurement Uncertainty

Compliance or non- compliance with a disturbance limit shall be determined in the following manner:
If Ulab is less than or equal to Ucispr of Table 1, then: -compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit; -non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit. If Ulab is greater than Ucispr of Table 1, then: -compliance is deemed to occur if no measured disturbance level, increased by (Ulab - Ucispr), exceeds the disturbance limit; -non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab - Ucispr), exceeds the disturbance limit.
Based on CISPR 16-4-2: 2011, measurement uncertainty of radiated emission at a distance of 10m at Bay Area Compliance Laboratories Corp. (Dongguan) is:30M~200MHz: 4.55 dB for Horizontal, 4.57 dB for Vertical; 200M~1GHz: 4.66 dB for Horizontal, 4.56 dB for Vertical; measurement uncertainty of radiated emission at a distance of 3m at Bay Area Compliance Laboratories Corp. (Dongguan) is:30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical; 200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical; 1G~6GHz: 4.45 dB, 6G~18GHz: 5.23 dB
Table 1 - Values of Ucispr

Measurement
Radiated disturbance (electric field strength at an OATS or in a SAC)(30 MHz to 1000 MHz) Radiated disturbance (electric field strength in a FAR)(1 GHz to 6 GHz) Radiated disturbance (electric field strength in a FAR)(6 GHz to 18 GHz)

Ucispr
6.3 dB 5.2 dB 5.5 dB

Test System Setup
Below 1GHz:

Page 11 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) Above 1GHz:

Report No.: DG1221220-62768E-02

The radiated emission tests below 1GHz were performed in 3 meters, above 1GHz were performed in the 3 meters. The specification used was EN 55032 Class B limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40cm long in the middle. The spacing between the peripherals was 10cm.

EMI Test Receiver and Spectrum Analyzer Setup

The system was investigated from 30 MHz to 6 GHz.

During the radiated emission test, the EMI test receiver(Below 1GHz) and Spectrum Analyzer(Above 1GHz) were set with the following configurations:

Frequency Range

RBW

Video B/W

IF B/W

Detector

30MHz - 1000 MHz Above 1 GHz

120 kHz 1MHz 1MHz

300 kHz 3 MHz 10Hz

120kHz / /

QP Peak Average

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is unnecessary to perform an QP/Average measurement.

Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation combinations.
All data was recorded in the Quasi-peak detection mode from 30MHz to 1GHz, Peak and average detection mode above 1GHz.

Corrected Amplitude & Margin Calculation
The basic equation is as follows: Result = Meter Reading+ Corrected Note: Corrected = Antenna Factor + Cable Loss - Amplifier Gain, or Corrected = Antenna Factor + Cable Loss + Insertion loss of attenuator - Amplifier Gain The "Margin" column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows: Margin = Limit-Result

Page 12 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Test Data
Please refer to following table and plots: Below 1G

Condition: Test Mode: Note:

EN 301 489 Class B M1: Operating &Wireless Linking RV1109

Report No.: DG1221220-62768E-02

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

30.0000

2

113.4200

3

175.5000

4

350.1000

5

549.9200

6

960.2300

Reading
(dBV)
33.13 42.19 43.66 35.84 31.68 28.75

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -11.38 -13.03 -9.52 -5.00 1.57

Result
(dBV/m)
29.79 30.81 30.63 26.32 26.68 30.32

Limit
(dBV/m)
40.00 40.00 40.00 47.00 47.00 47.00

Margin
(dB)
10.21 9.19 9.37 20.68 20.32 16.68

Page 13 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Condition: Test Mode: Note:

EN 301 489 Class B M1: Operating &Wireless Linking RV1109

Report No.: DG1221220-62768E-02

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

30.0000

2

42.6100

3

160.9500

4

174.5300

5

649.8300

6

960.2300

Reading
(dBV)
35.89 38.64 40.04 45.00 30.07 27.97

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -12.00 -12.26 -12.97 -3.10 1.57

Result
(dBV/m)
32.55 26.64 27.78 32.03 26.97 29.54

Limit
(dBV/m)
40.00 40.00 40.00 40.00 47.00 47.00

Margin
(dB)
7.45 13.36 12.22 7.97 20.03 17.46

Page 14 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1109

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

30.0000

2

155.1300

3

160.9500

4

450.0100

5

904.9400

6

994.1800

Reading
(dBV)
32.85 38.58 39.64 34.03 28.31 27.14

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -11.97 -12.26 -6.65 0.68 2.49

Result
(dBV/m)
29.51 26.61 27.38 27.38 28.99 29.63

Limit
(dBV/m)
40.00 40.00 40.00 47.00 47.00 47.00

Margin
(dB)
10.49 13.39 12.62 19.62 18.01 17.37

Page 15 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1109

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

30.0000

2

42.6100

3

174.5300

4

350.1000

5

649.8300

6

960.2300

Reading
(dBV)
36.88 37.83 40.57 36.48 29.80 28.79

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -12.00 -12.97 -9.52 -3.10 1.57

Result
(dBV/m)
33.54 25.83 27.60 26.96 26.70 30.36

Limit
(dBV/m)
40.00 40.00 40.00 47.00 47.00 47.00

Margin
(dB)
6.46 14.17 12.40 20.04 20.30 16.64

Page 16 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1109

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

30.0000

2

123.1200

3

350.1000

4

787.5700

5

897.1800

6

960.2300

Reading
(dBV)
33.56 31.09 36.91 27.94 27.75 28.66

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -10.84 -9.52 -1.40 0.63 1.57

Result
(dBV/m)
30.22 20.25 27.39 26.54 28.38 30.23

Limit
(dBV/m)
40.00 40.00 47.00 47.00 47.00 47.00

Margin
(dB)
9.78 19.75 19.61 20.46 18.62 16.77

Page 17 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1109

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

30.0000

2

42.6100

3

176.4700

4

350.1000

5

649.8300

6

960.2300

Reading
(dBV)
36.00 37.88 33.76 33.55 30.04 28.97

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -12.00 -13.08 -9.52 -3.10 1.57

Result
(dBV/m)
32.66 25.88 20.68 24.03 26.94 30.54

Limit
(dBV/m)
40.00 40.00 40.00 47.00 47.00 47.00

Margin
(dB)
7.34 14.12 19.32 22.97 20.06 16.46

Page 18 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Condition: Test Mode: Note:

EN 301 489 Class B M1: Operating &Wireless Linking RV1126

Report No.: DG1221220-62768E-02

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

30.0000

2

450.0100

3

750.7100

4

827.3400

5

850.6200

6

890.3900

Reading
(dBV)
34.37 35.35 33.84 32.26 31.70 31.82

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -6.65 -1.99 -0.66 -0.24 0.45

Result
(dBV/m)
31.03 28.70 31.85 31.60 31.46 32.27

Limit
(dBV/m)
40.00 47.00 47.00 47.00 47.00 47.00

Margin
(dB)
8.97 18.30 15.15 15.40 15.54 14.73

Page 19 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Condition: Test Mode: Note:

EN 301 489 Class B M1: Operating &Wireless Linking RV1126

Report No.: DG1221220-62768E-02

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

893.3000

2

30.0000

3

106.6300

4

149.3100

5

49.4000

6

827.3400

Reading
(dBV)
37.18 37.16 37.67 39.82 41.84 33.22

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
0.54 -3.34 -12.48 -11.74 -16.34 -0.66

Result
(dBV/m)
37.72 33.82 25.19 28.08 25.50 32.56

Limit
(dBV/m)
47.00 40.00 40.00 40.00 40.00 47.00

Margin
(dB)
9.28 6.18 14.81 11.92 14.50 14.44

Page 20 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Condition: Test Mode:
Note:

EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1126

Report No.: DG1221220-62768E-02

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

30.0000

2

450.0100

3

549.9200

4

649.8300

5

850.6200

6

890.3900

Reading
(dBV)
34.37 32.85 31.39 30.98 29.70 28.82

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -6.65 -5.00 -3.10 -0.24 0.45

Result
(dBV/m)
31.03 26.20 26.39 27.88 29.46 29.27

Limit
(dBV/m)
40.00 47.00 47.00 47.00 47.00 47.00

Margin
(dB)
8.97 20.80 20.61 19.12 17.54 17.73

Page 21 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1126

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

30.0000

2

66.8600

3

79.4700

4

149.3100

5

827.3400

6

893.3000

Reading
(dBV)
35.66 48.67 47.88 43.82 29.71 30.68

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -16.59 -16.68 -11.74 -0.66 0.54

Result
(dBV/m)
32.32 32.08 31.20 32.08 29.05 31.22

Limit
(dBV/m)
40.00 40.00 40.00 40.00 47.00 47.00

Margin
(dB)
7.68 7.92 8.80 7.92 17.95 15.78

Page 22 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1126

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

30.0000

2

149.3100

3

159.0100

4

549.9200

5

827.3400

6

890.3900

Reading
(dBV)
34.87 40.15 40.65 39.39 28.76 28.82

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -11.74 -12.15 -5.00 -0.66 0.45

Result
(dBV/m)
31.53 28.41 28.50 34.39 28.10 29.27

Limit
(dBV/m)
40.00 40.00 40.00 47.00 47.00 47.00

Margin
(dB)
8.47 11.59 11.50 12.61 18.90 17.73

Page 23 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1126

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

30.0000

2

106.6300

3

149.3100

4

750.7100

5

827.3400

6

893.3000

Reading
(dBV)
36.66 42.17 41.32 33.02 34.71 35.68

Detector
peak peak peak peak peak peak

Corrected
(dB/m)
-3.34 -12.48 -11.74 -1.99 -0.66 0.54

Result
(dBV/m)
33.32 29.69 29.58 31.03 34.05 36.22

Limit
(dBV/m)
40.00 40.00 40.00 47.00 47.00 47.00

Margin
(dB)
6.68 10.31 10.42 15.97 12.95 10.78

Page 24 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) Above 1G

Condition: Test Mode: Note:

EN 301 489 Class B M1: Operating &Wireless Linking RV1109

Report No.: DG1221220-62768E-02

Polarization: Distance:

Horizontal 3m

Fundamental

Frequency No.
(MHz)

1

3235.000

2

3235.000

3

3787.500

4

3787.500

5

5197.500

6

5197.500

Reading
(dBV)
51.36 39.25 49.56 37.46 49.26 37.57

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-6.59 -6.59 -5.01 -5.01 -1.30 -1.30

Result
(dBV/m)
44.77 32.66 44.55 32.45 47.96 36.27

Limit
(dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Margin
(dB)
29.23 21.34 29.45 21.55 26.04 17.73

Page 25 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Condition: Test Mode: Note:

EN 301 489 Class B M1: Operating &Wireless Linking RV1109

Report No.: DG1221220-62768E-02

Polarization: Distance:

Vertical 3m

Fundamental

Frequency No.
(MHz)

1

1542.500

2

1542.500

3

1710.000

4

1710.000

5

4140.000

6

4140.000

Reading
(dBV)
60.68 39.21 55.22 43.68 50.42 38.52

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-12.76 -12.76 -11.80 -11.80 -4.12 -4.12

Result
(dBV/m)
47.92 26.45 43.42 31.88 46.30 34.40

Limit
(dBV/m)
70.00 50.00 70.00 50.00 74.00 54.00

Margin
(dB)
22.08 23.55 26.58 18.12 27.70 19.60

Page 26 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1109

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

2402.500

2

2402.500

3

3310.000

4

3310.000

5

4190.000

6

4190.000

Reading
(dBV)
50.85 38.94 50.87 38.63 50.78 38.44

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-9.65 -9.65 -6.16 -6.16 -4.32 -4.32

Result
(dBV/m)
41.20 29.29 44.71 32.47 46.46 34.12

Limit
(dBV/m)
70.00 50.00 74.00 54.00 74.00 54.00

Margin
(dB)
28.80 20.71 29.29 21.53 27.54 19.88

Page 27 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1109

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

1162.500

2

1162.500

3

1332.500

4

1332.500

5

3135.000

6

3135.000

Reading
(dBV)
61.83 38.85 57.60 45.26 50.06 38.41

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-14.21 -14.21 -13.61 -13.61 -6.80 -6.80

Result
(dBV/m)
47.62 24.64 43.99 31.65 43.26 31.61

Limit
(dBV/m)
70.00 50.00 70.00 50.00 74.00 54.00

Margin
(dB)
22.38 25.36 26.01 18.35 30.74 22.39

Page 28 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1109

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

2402.500

2

2402.500

3

4305.000

4

4305.000

5

5600.000

6

5600.000

Reading
(dBV)
50.74 38.47 49.79 37.59 50.78 38.66

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-9.65 -9.65 -3.76 -3.76 -1.26 -1.26

Result
(dBV/m)
41.09 28.82 46.03 33.83 49.52 37.40

Limit
(dBV/m)
70.00 50.00 74.00 54.00 74.00 54.00

Margin
(dB)
28.91 21.18 27.97 20.17 24.48 16.60

Page 29 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1109

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

1225.000

2

1225.000

3

1917.500

4

1917.500

5

3875.000

6

3875.000

Reading
(dBV)
58.89 46.55 49.77 37.64 49.95 37.83

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-14.01 -14.01 -11.17 -11.17 -4.94 -4.94

Result
(dBV/m)
44.88 32.54 38.60 26.47 45.01 32.89

Limit
(dBV/m)
70.00 50.00 70.00 50.00 74.00 54.00

Margin
(dB)
25.12 17.46 31.40 23.53 28.99 21.11

Page 30 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Condition: Test Mode: Note:

EN 301 489 Class B M1: Operating &Wireless Linking RV1126

Report No.: DG1221220-62768E-02

Polarization: Distance:

Horizontal 3m

Fundamental

Harmonic spurious emissions

Frequency No.
(MHz)

1

3205.000

2

3205.000

3

3400.000

4

3400.000

5

5842.500

6

5842.500

Reading
(dBV)
52.35 40.57 50.69 38.49 50.64 38.86

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-6.58 -6.58 -5.63 -5.63 0.11 0.11

Result
(dBV/m)
45.77 33.99 45.06 32.86 50.75 38.97

Limit
(dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Margin
(dB)
28.23 20.01 28.94 21.14 23.25 15.03

Page 31 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Condition: Test Mode: Note:

EN 301 489 Class B M1: Operating &Wireless Linking RV1126

Report No.: DG1221220-62768E-02

Polarization: Distance:

Vertical 3m

Fundamental

Frequency No.
(MHz)

1

1767.500

2

1767.500

3

3400.000

4

3400.000

5

3767.500

6

3767.500

Reading
(dBV)
50.00 38.25 49.75 37.48 49.82 37.63

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-11.55 -11.55 -5.63 -5.63 -5.07 -5.07

Result
(dBV/m)
38.45 26.70 44.12 31.85 44.75 32.56

Limit
(dBV/m)
70.00 50.00 74.00 54.00 74.00 54.00

Margin
(dB)
31.55 23.30 29.88 22.15 29.25 21.44

Page 32 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Condition: Test Mode:
Note:

EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1126

Report No.: DG1221220-62768E-02

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

2607.500

2

2607.500

3

3307.500

4

3307.500

5

4087.500

6

4087.500

Reading
(dBV)
50.05 38.46 50.43 38.73 50.19 37.51

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-9.28 -9.28 -6.14 -6.14 -3.98 -3.98

Result
(dBV/m)
40.77 29.18 44.29 32.59 46.21 33.53

Limit
(dBV/m)
70.00 50.00 74.00 54.00 74.00 54.00

Margin
(dB)
29.23 20.82 29.71 21.41 27.79 20.47

Page 33 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1126

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

1365.000

2

1365.000

3

3045.000

4

3045.000

5

4310.000

6

4310.000

Reading
(dBV)
56.18 44.74 50.43 38.82 49.53 37.94

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-13.53 -13.53 -7.21 -7.21 -3.77 -3.77

Result
(dBV/m)
42.65 31.21 43.22 31.61 45.76 34.17

Limit
(dBV/m)
70.00 50.00 74.00 54.00 74.00 54.00

Margin
(dB)
27.35 18.79 30.78 22.39 28.24 19.83

Page 34 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1126

Polarization: Distance:

Horizontal 3m

Frequency No.
(MHz)

1

3220.000

2

3220.000

3

4107.500

4

4107.500

5

5170.000

6

5170.000

Reading
(dBV)
49.78 37.59 49.64 37.72 50.17 38.42

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-6.58 -6.58 -3.88 -3.88 -1.73 -1.73

Result
(dBV/m)
43.20 31.01 45.76 33.84 48.44 36.69

Limit
(dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Margin
(dB)
30.80 22.99 28.24 20.16 25.56 17.31

Page 35 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Condition: Test Mode:
Note:

EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1126

Polarization: Distance:

Vertical 3m

Frequency No.
(MHz)

1

2130.000

2

2130.000

3

3205.000

4

3205.000

5

4302.500

6

4302.500

Reading
(dBV)
50.43 38.77 49.99 37.68 49.83 37.54

Detector
peak AVG peak AVG peak AVG

Corrected
(dB/m)
-10.47 -10.47 -6.58 -6.58 -3.76 -3.76

Result
(dBV/m)
39.96 28.30 43.41 31.10 46.07 33.78

Limit
(dBV/m)
70.00 50.00 74.00 54.00 74.00 54.00

Margin
(dB)
30.04 21.70 30.59 22.90 27.93 20.22

Page 36 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
3 - AC MAINS POWER INPUT/OUTPUT PORTS
Test System Setup

Report No.: DG1221220-62768E-02

The setup of EUT is according with per EN 301 489-1 measurement procedures. The specification used was with the EN 301 489-1 limits. The external I/O cables were draped along the test table and formed a bundle 30 to 40cm long in the middle. The spacing between the peripherals was 10cm. The adapter was connected to AC230V/50Hz power source.
EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30MHz. During the conducted emission test, the EMI test receiver was set with the following configurations:

Frequency Range 150 kHz - 30 MHz

IF B/W 9 kHz

Test Procedure
During the conducted emissions test, the adapter was connected to the main outlet of the first LISN and the other support equipments were connected to the outlet of the second LISN.
Maximizing procedure was performed on the six (6) highest emissions of the EUT.
All data was recorded in the Quasi-peak and average detection mode.
Corrected Amplitude & Margin Calculation
The basic equation is as follows: Result (QuasiPeak or Average) = Meter Reading + Corr.
Note: Corr. = Cable loss + Factor of coupling device The "Margin" column of the following data tables indicates the degree of compliance within the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows: Margin = Limit -Result

Page 37 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Test Data

Please refer to following table and plots:

RV1109
Port: Test Mode:

L M1: Operating & Wireless Linking

Power Source: Note:

AC 230V/50Hz

Report No.: DG1221220-62768E-02

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.421178

---

0.683241

36.36

0.686657

---

0.781732

---

0.805479

30.79

1.373481

29.60

1.387250

---

2.562008

30.06

3.255003

---

4.346933

---

4.412464

28.94

11.439286

27.20

Average (dBV)
20.77 ---
28.78 23.43
----20.73 --19.83 19.14 -----

Limit (dBV)
47.42 56.00 46.00 46.00 56.00 56.00 46.00 56.00 46.00 46.00 56.00 60.00

Margin (dB)
26.65 19.64 17.22 22.57 25.21 26.40 25.27 25.94 26.17 26.86 27.06 32.80

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Corr. (dB)
9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 10.0

Page 38 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode:
Power Source: Note:

N M1: Operating & Wireless Linking
AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.199323

31.68

0.301537

30.34

0.421178

---

0.686657

---

0.686657

33.72

0.903386

---

0.926198

28.41

1.415204

---

1.415204

25.68

2.151633

---

4.523884

---

11.611735

24.58

Average (dBV)
----21.32 29.89 --24.63 --20.38 --20.33 18.81 ---

Limit (dBV)
63.64 60.20 47.42 46.00 56.00 46.00 56.00 46.00 56.00 46.00 46.00 60.00

Margin (dB)
31.96 29.86 26.10 16.11 22.28 21.37 27.59 25.62 30.32 25.67 27.19 35.42

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
N N N N N N N N N N N N

Corr. (dB)
9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.8

Page 39 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

L M2: Operating Wired Linking&TF Card Working AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.350205 0.683241 0.686657 0.805479 0.805479 1.373481 1.472813 2.562008 2.639835 4.368668 4.390511 11.553965

----36.36 --30.39 29.76 ----29.32 --28.35 30.52

Average (dBV)
21.80 28.84
--23.66
----21.22 20.18 --19.93 -----

Limit (dBV)
48.96 46.00 56.00 46.00 56.00 56.00 46.00 46.00 56.00 46.00 56.00 60.00

Margin (dB)
27.16 17.16 19.64 22.34 25.61 26.24 24.78 25.82 26.68 26.07 27.65 29.48

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Corr. (dB)
9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 10.0

Page 40 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

N M2: Operating Wired Linking&TF Card Working AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.200319 0.298544 0.416998 0.683241 0.690091 0.903386 0.978432 1.436538 1.480177 2.437361 3.222695 4.478982

31.95 29.30
--33.36
----26.50 25.00 --22.81 -----

Average (dBV)
----20.63 --29.92 24.12 ----20.38 --19.80 19.42

Limit (dBV)
63.60 60.28 47.51 56.00 46.00 46.00 56.00 56.00 46.00 56.00 46.00 46.00

Margin (dB)
31.65 30.98 26.88 22.64 16.08 21.88 29.50 31.00 25.62 33.19 26.20 26.58

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
N N N N N N N N N N N N

Corr. (dB)
9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6

Page 41 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

L M3: Operating & USB flash disk Working AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.427528 0.686657 0.686657 0.809506 0.829947 1.287253 1.465485 2.562008 2.574818 4.282376 4.802907 7.122346

----39.46 --34.31 33.62 ----34.06 --34.23 41.38

Average (dBV)
24.65 31.15
--26.47
----24.80 23.79 --23.42 -----

Limit (dBV)
47.30 46.00 56.00 46.00 56.00 56.00 46.00 46.00 56.00 46.00 56.00 60.00

Margin (dB)
22.65 14.85 16.54 19.53 21.69 22.38 21.20 22.21 21.94 22.58 21.77 18.62

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Corr. (dB)
9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.8

Page 42 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

N M3: Operating & USB flash disk Working AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.429665 0.686657 0.693541 0.926198 0.978432 1.380348 1.465485 2.562008 3.255003 4.456698 4.924186 6.809708

--35.77
----32.79 --30.37 30.51 ----29.63 37.06

Average (dBV)
24.42 ---
33.24 26.72
--25.15
----23.19 22.40 -----

Limit (dBV)
47.26 56.00 46.00 46.00 56.00 46.00 56.00 56.00 46.00 46.00 56.00 60.00

Margin (dB)
22.84 20.23 12.76 19.28 23.21 20.85 25.63 25.49 22.81 23.60 26.37 22.94

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
N N N N N N N N N N N N

Corr. (dB)
9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6

Page 43 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

RV1126
Port: Test Mode: Power Source: Note:

L M1: Operating &Wireless Linking AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.343287 0.683241 0.686657 0.809506 0.921590 1.401157 2.077810 2.679631 3.304072 4.501377 4.523884 11.269399

--37.97
----32.21 --31.00 --31.33 --30.96 33.37

Average (dBV)
24.43 ---
31.32 25.37
--22.72
--22.18
--22.05
-----

Limit (dBV)
49.12 56.00 46.00 46.00 56.00 46.00 56.00 46.00 56.00 46.00 56.00 60.00

Margin (dB)
24.69 18.03 14.68 20.63 23.79 23.28 25.00 23.82 24.67 23.95 25.04 26.63

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Corr. (dB)
9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 10.0

Page 44 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

N M1: Operating &Wireless Linking AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.218045 0.431814 0.686657 0.686657 0.912443 1.075686 1.353083 1.487578 2.613633 3.387504 4.501377 11.964470

32.02 -----
35.18 ---
27.92 27.37
--25.80
----29.87

Average (dBV)
--22.77 31.87
--25.25
----23.00 --22.38 21.63 ---

Limit (dBV)
62.89 47.22 46.00 56.00 46.00 56.00 56.00 46.00 56.00 46.00 46.00 60.00

Margin (dB)
30.87 24.45 14.13 20.82 20.75 28.08 28.63 23.00 30.20 23.62 24.37 30.13

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
N N N N N N N N N N N N

Corr. (dB)
9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.8

Page 45 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

L M2:Operating&Wired Linking&TF Card Working AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.309151 0.683241 0.683241 0.829947 0.926198 1.380348 2.077810 2.140929 2.653034 4.546503 4.569236 10.098279

----37.53 --32.06 --31.82 --31.79 31.15 --33.97

Average (dBV)
23.34 30.08
--24.98
--22.29
--21.93
----20.45 ---

Limit (dBV)
49.99 46.00 56.00 46.00 56.00 46.00 56.00 46.00 56.00 56.00 46.00 60.00

Margin (dB)
26.65 15.92 18.47 21.02 23.94 23.71 24.18 24.07 24.21 24.85 25.55 26.03

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Corr. (dB)
9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.9

Page 46 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

N M2:Operating&Wired Linking&TF Card Working AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.427528 0.683241 0.686657 0.930829 1.023352 1.249302 1.387250 2.562008 3.370651 4.592082 10.098279 10.667780

----34.77 --28.94 27.20 --25.95 ----32.26 30.56

Average (dBV)
22.38 31.28
--25.13
----22.37 --22.29 22.13 -----

Limit (dBV)
47.30 46.00 56.00 46.00 56.00 56.00 46.00 56.00 46.00 46.00 60.00 60.00

Margin (dB)
24.92 14.72 21.23 20.87 27.06 28.80 23.63 30.05 23.71 23.87 27.74 29.44

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
N N N N N N N N N N N N

Corr. (dB)
9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.7 9.7

Page 47 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

L M3:Operating&Wired Linking&USB flash disk Working AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.431814 0.683241 0.686657 0.801471 0.805479 1.415204 2.077810 2.720027 2.720027 4.478982 4.478982 10.048039

--38.09
--32.37
----32.34 33.36 --32.20 --35.59

Average (dBV)
22.99 ---
31.33 ---
26.02 22.85
----23.17 --22.50 ---

Limit (dBV)
47.22 56.00 46.00 56.00 46.00 46.00 56.00 56.00 46.00 56.00 46.00 60.00

Margin (dB)
24.23 17.91 14.67 23.63 19.98 23.15 23.66 22.64 22.83 23.80 23.50 24.41

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Corr. (dB)
9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.9

Page 48 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

N M3:Operating&Wired Linking&USB flash disk Working AC 230V/50Hz

Level in dB

80 70 60 50 40 30 20 10
0 150k

Class B Voltage on Mains QP Class B Voltage on Mains AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.431814 0.686657 0.690091 0.926198 1.008154 1.300158 1.487578 2.140929 2.574818 4.478982 4.546503 8.068162

--35.98
----29.95 27.96 ----28.52 26.77 --32.97

Average (dBV)
24.16 ---
32.65 26.34
----24.03 23.95 ----23.47 ---

Limit (dBV)
47.22 56.00 46.00 46.00 56.00 56.00 46.00 46.00 56.00 56.00 46.00 60.00

Margin (dB)
23.06 20.02 13.35 19.66 26.05 28.04 21.97 22.05 27.48 29.23 22.53 27.03

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
N N N N N N N N N N N N

Corr. (dB)
9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.7

Page 49 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

5 - VOLTAGE FLUCTUATIONS AND FLICKER (AC MAINS INPUT PORT)

Test System Setup

AC Mains

AC Source

Analyzer

EUT System

Wooden Table

80cm

Test Standard
EN 61000-3-3:2013+A1:2019+A2:2021
Flicker Test Limits:
The limits shall be applicable to voltage fluctuations and flicker at the supply terminals of the equipment under test, measured or calculated according to clause 4 under test conditions described in clause 6 and annex A. Tests made to prove compliance with the limits are considered to be type tests. The following limits apply: - the value of Pst shall not be greater than 1,0; - the value of Plt shall not be greater than 0,65; - the value of d(t) during a voltage change shall not exceed 3,3 % for more than 500 ms; - the relative steady-state voltage change, dc, shall not exceed 3,3 %; - the maximum relative voltage change dmax, shall not exceed a) 4 % without additional conditions; b) 6 % for equipment which is: ­ switched manually, or
- switched automatically more frequently than twice per day, and also has either adelayed restart (the delay being not less than a few tens of seconds), or manual restart, after a power supply interruption. Note: The cycling frequency will be further limited by the Pst and Plt limit. For example: a dmax of 6 % producing a rectangular voltage change characteristic twice per hour will give a Plt of about 0,65. c) 7 % for equipment which is - attended whilst in use (for example: hair dryers, vacuum cleaners, kitchen equipment such as mixers, garden equipment such as lawn mowers, portable tools such as electric drills), or - switched on automatically, or is intended to be switched on manually, no more than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds) or manual restart, after a power supply interruption.
In the case of equipment having several separately controlled circuits in accordance with 6.6,limits b) and c) shall apply only if there is delayed or manual restart after a power supply interruption; for all equipment with automatic switching which is energized immediately on restoration of supply after a power supply interruption, limits a) shall apply; for all equipment with manual switching, limits b) or c) shall apply depending on the rate of switching. Pst and Plt requirements shall not be applied to voltage changes caused by manual switching. The limits shall not be applied to voltage changes associated with emergency switching or emergency interruptions.

Page 50 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
Test Data

Report No.: DG1221220-62768E-02

Please refer to following tables:

RV1109
Short time (Pst): Observation time: Test Mode:
Power Source: Test Result

10 min 120 min (12 Flicker measurement) M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working AC 230V/50Hz
PASS

Maximum Flicker resultsM1

Pst Plt dc [%] dmax [%] dt [s]

EUT values 0.028 0.028 0.012 0.253 0.000

Limit 1.00 0.65 3.30 4.00 0.50

Result PASS PASS PASS PASS PASS

Maximum Flicker resultsM2

Pst Plt dc [%] dmax [%] dt [s]

EUT values 0.028 0.028 0.016 0.224 0.000

Limit 1.00 0.65 3.30 4.00 0.50

Result PASS PASS PASS PASS PASS

Maximum Flicker resultsM3

Pst Plt dc [%] dmax [%] dt [s]

EUT values 0.028 0.028 0.015 0.213 0.000

Limit 1.00 0.65 3.30 4.00 0.50

Result PASS PASS PASS PASS PASS

Page 51 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

RV1126
Short time (Pst): Observation time: Test Mode:
Power Source: Test Result

10 min 120 min (12 Flicker measurement) M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working
AC 230V/50Hz
PASS

Maximum Flicker results (M1)

Report No.: DG1221220-62768E-02

Pst Plt dc [%] dmax [%] dt [s]

EUT values 0.028 0.028 0.013 0.221 0.000

Limit 1.00 0.65 3.30 4.00 0.50

Result PASS PASS PASS PASS PASS

Maximum Flicker results (M2)

Pst Plt dc [%] dmax [%] dt [s]

EUT values 0.028 0.028 0.015 0.236 0.000

Limit 1.00 0.65 3.30 4.00 0.50

Result PASS PASS PASS PASS PASS

Maximum Flicker results (M3)

Pst Plt dc [%] dmax [%] dt [s]

EUT values 0.028 0.028 0.015 0.241 0.000

Limit 1.00 0.65 3.30 4.00 0.50

Result PASS PASS PASS PASS PASS

Page 52 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
6 - WIRED NETWORK PORTS
Test System Setup

Report No.: DG1221220-62768E-02

The setup of EUT is according with per EN 301 489-1 measurement procedures. The specification used was with the EN 301 489-1 limits.
The external I/O cables were draped along the test table and formed a bundle 30 to 40cm long in the middle.
The spacing between the peripherals was 10cm.

EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30MHz During the conducted emission test, the EMI test receiver was set with the following configurations:

Frequency Range 150 kHz - 30 MHz

IF B/W 9 kHz

Test Procedure
During the conducted emissions test, the adapter was connected to the main outlet of the first LISN and the other support equipments were connected to the outlet of the second LISN.
Maximizing procedure was performed on the six (6) highest emissions of the EUT.
All data was recorded in the Quasi-peak and average detection mode.
Corrected Amplitude & Margin Calculation
The basic equation is as follows: Result (QuasiPeak or Average) = Meter Reading + Corr.
Note: Corr. = Cable loss + Factor of coupling device The "Margin" column of the following data tables indicates the degree of compliance within the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows: Margin = Limit -Result

Page 53 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Test Data

Please refer to following table and plots:

RV1109

Port:

RJ45

Test Mode:

10Mbps

Power Source:

AC 230V/50Hz

Note:

M2: Operating Wired Linking&TF Card Working

100

80

Class B Voltage on Telcom QP

Class B Voltage on Telcom Average 60

Level in dB

40

20

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.260930 0.429665

59.65 ---

0.429665 0.511614 0.543169 0.663098 0.666413 0.881136 1.023352 1.366648 13.418776 16.963591

60.74 59.88
----58.33 57.88 --55.34 -----

Average (dBV)
--51.60
----51.30 51.76 ----49.57 --51.48 48.85

Limit (dBV)
79.40 65.26 75.26 74.00 64.00 64.00 74.00 74.00 64.00 74.00 64.00 64.00

Margin (dB)
19.75 13.66 14.52 14.12 12.70 12.24 15.67 16.12 14.43 18.66 12.52 15.15

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal

Corr. (dB)
9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6 9.6

Page 54 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

RJ45 100Mbps AC 230V/50Hz M2: Operating Wired Linking&TF Card Working

100

80

Class B Voltage on Telcom QP

Class B Voltage on Telcom Average 60

Level in dB

40

20

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.301537 0.419083 0.419083 0.509069 0.527156 0.666413 0.666413 1.018261 1.153481 1.280849 13.418776 16.963591

60.40 ---
60.63 ---
59.91 58.98
----56.79 55.21 -----

Average (dBV)
--51.88
--51.00
----51.67 49.86 ----51.46 48.74

Limit (dBV)
78.20 65.47 75.47 64.00 74.00 74.00 64.00 64.00 74.00 74.00 64.00 64.00

Margin (dB)
17.80 13.59 14.84 13.00 14.09 15.02 12.33 14.14 17.21 18.79 12.54 15.26

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal

Corr. (dB)
9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6 9.6

Page 55 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

RJ45 10Mbps AC 230V/50Hz M3: Operating & USB flash disk Working

100

80

Class B Voltage on Telcom QP

Class B Voltage on Telcom Average 60

Level in dB

40

20

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.303044 0.406728 0.423284 0.453897 0.537778 0.659799 0.663098 0.881136 1.023352 1.268136 13.418776 16.963591

60.30 ---
60.59 59.71
--58.75
--57.79
--56.10
-----

Average (dBV)
--51.45
----50.45 --50.98 --50.14 --51.40 48.98

Limit (dBV)
78.16 65.71 75.38 74.80 64.00 74.00 64.00 74.00 64.00 74.00 64.00 64.00

Margin (dB)
17.86 14.26 14.79 15.09 13.55 15.25 13.02 16.21 13.86 17.90 12.60 15.02

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal

Corr. (dB)
9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6 9.6

Page 56 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

RJ45 100Mbps AC 230V/50Hz M3: Operating & USB flash disk Working

100

80

Class B Voltage on Telcom QP

Class B Voltage on Telcom Average 60

Level in dB

40

20

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.292647 0.386939 0.429665 0.551358 0.551358 0.656516 0.663098 1.023352 1.023352 1.268136 13.418776 24.536148

60.73 60.35
----58.99 59.04 --57.31 --56.59 -----

Average (dBV)
----52.26 51.08 ----52.10 --50.43 --51.78 49.14

Limit (dBV)
78.45 76.13 65.26 64.00 74.00 74.00 64.00 74.00 64.00 74.00 64.00 64.00

Margin (dB)
17.72 15.78 13.00 12.92 15.01 14.96 11.90 16.69 13.57 17.41 12.22 14.86

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal

Corr. (dB)
9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6 9.8

Page 57 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

RV1126
Port: Test Mode: Power Source: Note:

RJ45 10Mbps AC 230V/50Hz M2:Operating&Wired Linking&TF Card Working

100

80

Class B Voltage on Telcom QP

Class B Voltage on Telcom Average 60

Level in dB

40

20

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.301537 0.412859 0.423284 0.516743 0.516743 0.659799 0.659799 0.881136 0.894420 1.332988 1.332988 9.998049

--60.94
--60.12
--59.11
--57.89
--56.12
--57.31

Average (dBV)
53.89 ---
54.28 ---
52.92 ---
52.82 ---
50.94 ---
48.66 ---

Limit (dBV)
68.20 75.59 65.38 74.00 64.00 74.00 64.00 74.00 64.00 74.00 64.00 74.00

Margin (dB)
14.31 14.65 11.10 13.88 11.08 14.89 11.18 16.11 13.06 17.88 15.34 16.69

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal

Corr. (dB)
9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.7 9.6

Page 58 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

RJ45 100Mbps AC 230V/50Hz M2:Operating&Wired Linking&TF Card Working

100

80

Class B Voltage on Telcom QP

Class B Voltage on Telcom Average 60

Level in dB

40

20

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.292647 0.297058 0.406728 0.421178 0.504016 0.527156 0.656516 0.659799 0.898892 1.013195 1.373481 17.831112

61.40 ---
60.75 ---
59.60 ---
60.84 ---
57.76 -----
58.20

Average (dBV)
--52.32
--52.41
--51.45
--52.04
--49.23 47.18
---

Limit (dBV)
78.45 68.32 75.71 65.42 74.00 64.00 74.00 64.00 74.00 64.00 64.00 74.00

Margin (dB)
17.05 16.00 14.96 13.01 14.40 12.55 13.16 11.96 16.24 14.77 16.82 15.80

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal

Corr. (dB)
9.9 9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6

Page 59 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

RJ45 10Mbps AC 230V/50Hz M3:Operating&Wired Linking&USB flash disk Working

100

80

Class B Voltage on Telcom QP

Class B Voltage on Telcom Average 60

Level in dB

40

20

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.303044 0.392773 0.429665 0.516743 0.537778 0.640347 0.650000 0.894420 0.903386 1.249302 1.339653 9.998049

--59.77
--58.89
--58.57
----56.22 55.42 --57.18

Average (dBV)
52.80 ---
53.00 ---
52.27 ---
52.07 49.67
----47.41 ---

Limit (dBV)
68.16 76.00 65.26 74.00 64.00 74.00 64.00 64.00 74.00 74.00 64.00 74.00

Margin (dB)
15.36 16.23 12.26 15.11 11.73 15.43 11.93 14.33 17.78 18.58 16.59 16.82

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal

Corr. (dB)
9.9 9.8 9.8 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.6

Page 60 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Port: Test Mode: Power Source: Note:

RJ45 100Mbps AC 230V/50Hz M3:Operating&Wired Linking&USB flash disk Working

100

80

Class B Voltage on Telcom QP

Class B Voltage on Telcom Average 60

Level in dB

40

20

0 150k

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

Final_Result

Frequency QuasiPeak

(MHz)

(dBV)

0.300036 0.303044 0.390819 0.390819 0.438323 0.554114 0.633991 0.640347 0.885542 0.903386 1.249302 1.255549

--59.06
--59.49
--58.75
--58.51 56.49
----54.89

Average (dBV)
50.62 ---
50.60 ---
50.36 ---
50.13 -----
48.24 46.18
---

Limit (dBV)
68.24 78.16 66.05 76.05 65.09 74.00 64.00 74.00 74.00 64.00 64.00 74.00

Margin (dB)
17.62 19.10 15.45 16.56 14.73 15.25 13.87 15.49 17.51 15.76 17.82 19.11

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal

Corr. (dB)
9.9 9.9 9.8 9.8 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7

Page 61 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

7 - RADIO FREQUENCY ELECTROMAGNETIC FIELDS (80 MHZ TO 6 000 MHZ)

Test System Setup

Anechoic

Chamber

3m

Power Amplifier

Signal Generator

EUT System
Wooden table 80 cm

Test Level

Level
1. 2. 3. X.

Field Strength V/m
1 3 10 Special

Performance Criterion: A

General Performance Criteria: A. The apparatus shall continue to operate as intended during and after the test. The manufacturer specifies some
minimum performance level. The performance level may be specified by the manufacture as a permissible loss of performance. B. The apparatus shall continue to operate as intended after the test. This indicates that the EUT does not need to function at normal performance levels during the test, but must recover. Again some minimal performance is defined by the manufacture. No change in operating state or loss or data is permitted. C. Temporary loss of function is allowed. Operation of the EUT may stop as long as it is either automatically reset or can be manually restored by operation of the controls. D. The apparatus is broken, cannot be normal operated.

Page 62 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Test Procedure
The EUT and its simulators are placed on a turn table which is 0.8 meter above the ground. The EUT is set 3 meters away from the antenna which is mounted on an antenna tower. Both horizontal and vertical polarizations of the antenna are set on test. Each of the four sides of EUT must be faced this antenna and measured individually.

Test Data
Please refer to following tables:

Test Mode: Note:

M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working

Condition of Test Field Strength RF Signal
Sweep Frequency Step Dwell Time

3 V/m (Test Level 2) 1 kHz, 80% AM, sine wave 1%, logarithmic 1 Sec

Remarks

RV1109 Frequency
Range (MHz)
80-1000
1000-6000

Front Side

VERT

HORI

A

A

A

A

Rear Side

VERT

HORI

A

A

A

A

Left Side VERT HORI

A

A

A

A

Right Side VERT HORI

A

A

A

A

RV1126 Frequency
Range (MHz)
80-1000
1000-6000

Front Side

VERT

HORI

A

A

A

A

Rear Side

VERT

HORI

A

A

A

A

Left Side VERT HORI

A

A

A

A

Right Side VERT HORI

A

A

A

A

Note: "A" stand for, during test, operate as intended no loss of function, no degradation of performance, no unintentional transmissions and after test, no degradation of performance, no loss of function, no loss of stored data or user programmable functions.

Page 63 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
8 - ELECTROSTATIC DISCHARGES

Report No.: DG1221220-62768E-02

Test System Setup

Adapter

AC Mains

EUT System
Wooden Table

ESD Tester

80 cm

Remark:

is the tip of the electrode

EN61000-4-2 specifies that a tabletop EUT shall be placed on a non-conducting table which is 80 centimeters above a ground reference plane and that floor mounted equipment shall be placed on a insulating support approximately 10 centimeters above a ground plane. During the tests, the EUT is positioned over a ground reference plane in conformance with this requirement.

For tabletop equipment, a 1.6 by 0.8-meter metal sheet (HCP) is placed on the table and connected to the ground plane via a metal strap with two 470 k Ohms resistors in series. The EUT and attached cables are isolated from this metal sheet by 0.5-millimeter thick insulating material. A Vertical Coupling Plane (VCP) grounded on the ground plane through the same configuration as in the HCP is used.

Test Level

Level 1.

Test Voltage Contact Discharge (±kV)
2

2.

4

3.

6

4.

8

X.

Special

Test Level 3 for Air Discharge at ±8 kV Test Level 2 for Direct Discharge at ±4 kV

Test Voltage Air Discharge (±kV)
2
4
8
15
Special

Performance criterion: B

Test Procedure

Air Discharge: This test is done on a non-conductive surface. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed.
Contact Discharge: All the procedure shall be same as Section 8.3.1 of EN 61000-4-2, except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated.
Indirect discharge for horizontal coupling plane At least 50 single discharges shall be applied to the horizontal coupling plane, at points on each side of the EUT. The discharge electrode positions vertically at a distance of 0.1m from the EUT and with the discharge electrode touching the coupling plane.
Indirect discharge for vertical coupling plane At least 50 single discharges shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated.

Page 64 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Test Data

Please refer to following tables:

RV1109

Test Mode: Note:

M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working

Table 1: Electrostatic Discharge Immunity (Air Discharge)

Test Points Location
Non-metallic Shell USB Port TF card Port RJ45 USB Cable Reticle Button Seam

Test Level

-2 kV
A

+2 kV
A

-4 kV
A

+4 kV
A

-8 kV
A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

Table 2: Electrostatic Discharge Immunity (Direct Contact)

Test Points Location
/

-2 kV
/

+2 kV
/

-4 kV
/

Test Level

+4 kV

-6 kV

/

/

Table 3: Electrostatic Discharge Immunity (Indirect Contact HCP)

Test Points Location
Front Side Back Side Left Side Right Side

Test Level

-2 kV
A

+2 kV
A

-4 kV
A

+4 kV
A

-6 kV
/

A

A

A

A

/

A

A

A

A

/

A

A

A

A

/

Table 4: Electrostatic Discharge Immunity (Indirect Contact VCP)

Test Points Location
Front Side Back Side Left Side Right Side

Test Level

-2 kV

+2 kV

-4 kV

+4 kV

-6 kV

A

A

A

A

/

A

A

A

A

/

A

A

A

A

/

A

A

A

A

/

+8 kV
A A A A A A A A
+6 kV
/
+6 kV
/ / / /
+6 kV
/ / / /

-15 kV
/ / / / / / / /

+15 kV
/ / / / / / / /

-8 kV
/

+8 kV
/

-8 kV
/ / / /

+8 kV
/ / / /

-8 kV
/ / / /

+8 kV
/ / / /

Page 65 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) ESD Location Photo

Report No.: DG1221220-62768E-02

Air Discharge:

Direct Contact:

RV1126

Test Mode: Note:

M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working

Table 1: Electrostatic Discharge Immunity (Air Discharge)

Test Points Location
Non-metallic Shell USB Port TF card Port RJ45 USB Cable Reticle Button Seam

Test Level

-2 kV
A

+2 kV
A

-4 kV
A

+4 kV
A

-8 kV
A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

+8 kV
A A A A A A A A

-15 kV
/ / / / / / / /

+15 kV
/ / / / / / / /

Page 66 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Table 2: Electrostatic Discharge Immunity (Direct Contact)

Test Points Location
/

-2 kV
/

+2 kV
/

-4 kV
/

Test Level

+4 kV

-6 kV

/

/

+6 kV
/

-8 kV
/

+8 kV
/

Table 3: Electrostatic Discharge Immunity (Indirect Contact HCP)

Test Points Location Front Side

-2 kV
A

+2 kV
A

-4 kV
A

Test Level

+4 kV

-6 kV

A

/

+6 kV
/

-8 kV
/

+8 kV
/

Back Side

A

A

A

A

/

/

/

/

Left Side

A

A

A

A

/

/

/

/

Right Side

A

A

A

A

/

/

/

/

Table 4: Electrostatic Discharge Immunity (Indirect Contact VCP)

Test Points Location

-2 kV

+2 kV

-4 kV

Test Level

+4 kV

-6 kV

+6 kV

-8 kV

+8 kV

Front Side

A

A

A

A

/

/

/

/

Back Side

A

A

A

A

/

/

/

/

Left Side

A

A

A

A

/

/

/

/

Right Side

A

A

A

A

/

/

/

/

ESD Location Photo

Air Discharge:

Direct Contact:

Page 67 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
9 - FAST TRANSIENTS, COMMON MODE
Test System Setup
Ground Reference Plane

Report No.: DG1221220-62768E-02
EUT Wooden Table

80cm 10cm
Grounding Cable

Test Level

Ground Reference Plane

Level
1 2 3 4 X

Open Circuit Output Test Voltage ±10

On Power Supply Lines
0.5 kV 1 kV 2 kV 4 kV Special

On I/O (Input/Output) Signal data and control lines 0.25 kV 0.5 kV 1 kV 2 kV Special

Performance Criterion: B

Test Procedure

The EUT was arranged for Power Line Coupling and for I/O Line Coupling through a capacitive clamp, where applicable. (Note: The I/O coupling test using a capacitive clamp is performed on the I/O interface cables that are longer in length than 3 meters.) A metal ground plane 2.4 meter by 2.0 meter was placed between the floor and the table and is connected to the earth by a 2.0 meter ground rod. The ground rod is connected to the test facility's electrical earth.

Page 68 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Test Data

Please refer to following tables: RV1109

Test Mode: Note:

M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working

Test Points

L

N

AC mains power input ports

Earth L+N L + Earth

N + Earth

L+N+Earth

Signal ports

RJ45

Test Level (kV)

+0.5 -0.5 +1.0 -1.0 +2.0 -2.0 +4.0 -4.0

A

A

A

A

/

/

/

/

A

A

A

A

/

/

/

/

/

/

/

/

/

/

/

/

A

A

A

A

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

A A

/

/

/

/

/

/

RV1126

Test Mode: Note:

M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working

Test Points

L

N

Earth

AC mains power L+N

input ports

L + Earth

N + Earth

L+N+Earth

Signal ports

RJ45

Test Level (kV)

+0.5 -0.5 +1.0 -1.0 +2.0 -2.0 +4.0 -4.0

A

A

A

A

/

/

/

/

A

A

A

A

/

/

/

/

/

/

/

/

/

/

/

/

A

A

A

A

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

A A

/

/

/

/

/

/

Page 69 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
10 - RADIO FREQUENCY, COMMON MODE
Test System Setup

Report No.: DG1221220-62768E-02

EUT

SG

CDN

Wooden Table

10 cm

Test Level

Level
1 2 3 X

Voltage Level (r.m.s.) (U0) 1
3
10
Special

Performance Criterion: A
Test Procedure
1)Let the EUT work in test mode and test it. 2)The EUT are placed on an insulating support 0.1 m high above a ground reference plane. CDN (coupling and
decoupling device) is placed on the ground plane about 0.3 m from EUT. Cables between CDN and EUT are as short as possible, and their height above the ground reference plane shall be between 30 and 50 mm (where possible). 3)The disturbance signal described below is injected to EUT through CDN. 4)The EUT operates within its operational mode(s) under intended climatic conditions after power on. 5)The frequency range is swept from 150 kHz to 80 MHz using 3V signal level, and with the disturbance signal 80% amplitude modulated with a 1 kHz sine wave. 6) Where the frequency is swept incrementally, the step size shall not exceed 1 % of the preceding frequency value. The dwell time of the amplitude modulated carrier at each frequency shall not be less than the time necessary for the EUT to be exercised and to respond, but shall in no case be less than 0.5 s. 7) Recording the EUT operating situation during compliance testing and decide the EUT immunity criterion.

Page 70 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Test Data

Please refer to following tables:

RV1109

Test Mode: Note:

M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working

Table 1: AC mains power input port

Frequency range:150kHz to80MHz

Modulated:

Amplitude 80%, 1kHz sine wave

Severity Level: 3V Unmodulated , r.m.s

 Unmodulated  Other:

Level

Voltage Level (e.m.f.) U0

Pass

Fail

1

1

/

/

2

3

A

/

3

10

/

/

X

Special

/

/

Table 2: Signal Port :____RJ45___

Frequency range: 150 kHz to80MHz

Modulated:

Amplitude 80%, 1kHz sine wave

Severity Level: 3 V Unmodulated , r.m.s

Unmodulated  Other:

Level

Voltage Level (e.m.f.) U0

Pass

Fail

1

1

/

/

2

3

A

/

3

10

/

/

X

Special

/

/

Page 71 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

RV1126

Test Mode: Note:

M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working

Table 1: AC mains power input port

Frequency range:150kHz to80MHz

Modulated:

Amplitude 80%, 1kHz sine wave

Severity Level: 3V Unmodulated , r.m.s

 Unmodulated  Other:

Level

Voltage Level (e.m.f.) U0

Pass

Fail

1

1

/

/

2

3

A

/

3

10

/

/

X

Special

/

/

Table 2: Signal Port :____RJ45___

Frequency range: 150 kHz to80MHz

Modulated:

Amplitude 80%, 1kHz sine wave

Severity Level: 3 V Unmodulated , r.m.s

Unmodulated  Other:

Level

Voltage Level (e.m.f.) U0

Pass

Fail

1

1

/

/

2

3

A

/

3

10

/

/

X

Special

/

/

Page 72 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

12 - VOLTAGE DIPS AND SHORT INTERRUPTIONS

Test System Setup

Ground Reference Plane

EUT Wooden Table

80cm 10cm
Grounding Cable

Test Level and Performance Criterion

Ground Reference Plane

Test Level
1 2 3 4

Voltage dip and short interruptions (% ) Residual 0 0
70 0

Duration (in period)
0.5 1 25 250

Performance criterion
B B C C

Test Procedure
1) The interruption is introduced at selected phase angles with specified duration. 2) Record any degradation of performance.

Page 73 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Test Data

Please refer to following tables:

RV1109

Test Mode: Note:

M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working B indicates that the power supply of the EUT was interrupted during the test, and the EUT was restarted. After the test, it can automatically return to normal use.

Table 1: Voltage Dips/Interruptions Test

U2 (% Reduction) Td (Periods) Phase Angle

N

100

0.5

0/90/180/270

3

100

1

0/90/180/270

3

30

25

0/90/180/270

3

100

250

0/90/180/270

3

Result A A A B

RV1126

Test Mode: Note:

M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working B indicates that the power supply of the EUT was interrupted during the test, and the EUT was restarted. After the test, it can automatically return to normal use.

Table 1: Voltage Dips/Interruptions Test

U2 (% Reduction) Td (Periods) Phase Angle

N

100

0.5

0/90/180/270

3

100

1

0/90/180/270

3

30

25

0/90/180/270

3

100

250

0/90/180/270

3

Result A A A B

Page 74 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
13 - SURGES
Test System Setup
Ground Reference Plane

Report No.: DG1221220-62768E-02
EUT Wooden Table

80cm 10cm
Grounding Cable

Test Level

Ground Reference Plane

Level 1 2 3 4 X

Open Circuit Output Test Voltage ±10 0.5 kV 1 kV 2 kV 4 kV Special

Performance Criterion: B
Test Procedure
1) For line to line coupling mode, provide a 0.5 kV 1.2/50us voltage surge (at open-circuit condition). 2) At least 5 positive and 5 negative (polarity) tests with a maximum 1/min repetition rate are conducted
during test. 3) Different phase angles are done individually. 4) Record the EUT operating situation during compliance test and decide the EUT immunity criterion for
above each test.

Page 75 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Test Data

Please refer to following tables:

RV1109

Test Mode: Note:

M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working

Table 1:AC mains power input port

Level

Voltage

Poll

1

0.5kV

±

2

1kV

±

3

2kV

±

4

4kV

±

Path Line-Line Line-Line
/ /

Table 2:

RJ45

I/O Circuit and Lines

Level

Voltage

Poll

1

0.5kV

±

2

1kV

±

3

2kV

±

Path
Line-Ground Line-Ground Line-Ground

RV1126

Test Mode: Note:

M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working

Table 1: AC mains power input port

Level

Voltage

Poll

1

0.5kV

±

2

1kV

±

3

2kV

±

4

4kV

±

Path Line-Line Line-Line
/ /

Table 2: RJ45 I/O Circuit and Lines

Level

Voltage

Poll

1

0.5kV

±

2

1kV

±

3

2kV

±

Path
Line-Ground / /

Report No.: DG1221220-62768E-02

Pass

Fail

A

/

A

/

/

/

/

/

Pass

Fail

A

/

/

/

/

/

Pass

Fail

A

/

A

/

/

/

/

/

Pass

Fail

A

/

/

/

/

/

Page 76 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
EXHIBITA - EUT PHOTOGRAPHS

Report No.: DG1221220-62768E-02

Page 77 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Page 78 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Page 79 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Page 80 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) Port

Report No.: DG1221220-62768E-02

Port

Page 81 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) Uncover

Report No.: DG1221220-62768E-02

Page 82 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Page 83 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Page 84 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) Zigbee Antenna

Report No.: DG1221220-62768E-02

BLE&WiFi Antenna

Page 85 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Page 86 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

RV1126

Page 87 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Chip

Page 88 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) Chip

Report No.: DG1221220-62768E-02

CPU BoardRV1126

Page 89 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Chip

Page 90 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Chip

Page 91 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Page 92 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) Chip

Report No.: DG1221220-62768E-02

Chip

Page 93 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Note: The onboard antenna is not used. Chip

Page 94 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
CPU Board (RV1109)

Report No.: DG1221220-62768E-02

Page 95 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) Chip

Report No.: DG1221220-62768E-02

Chip

Page 96 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Page 97 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) Chip

Report No.: DG1221220-62768E-02

Page 98 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Report No.: DG1221220-62768E-02

Page 99 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
EXHIBITB - TEST SETUP PHOTOGRAPHS
RE
RE Below 1GHz front View

Report No.: DG1221220-62768E-02

RE Below 1GHz rear View

Page 100 of 110

Bay Area Compliance Laboratories Corp. (Dongguan) RE Above 1GHz front View

Report No.: DG1221220-62768E-02

RE Above 1GHz rear View

Page 101 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

CE_AC

CE front View

Report No.: DG1221220-62768E-02

CE side View

Page 102 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

CE_ISN

CE front View

Report No.: DG1221220-62768E-02

CE side View

Page 103 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Flicker

Test Setup Photo View M1

Report No.: DG1221220-62768E-02

Page 104 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
RS
Test Setup Photo View

Report No.: DG1221220-62768E-02

Page 105 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

ESD

Test Setup Photo View

Report No.: DG1221220-62768E-02

Page 106 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

EFT

Test Setup Photo View

Report No.: DG1221220-62768E-02

Signal Port Test Setup Photo

Page 107 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Dips

Test Setup Photo View

Report No.: DG1221220-62768E-02

Page 108 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)

Surge

Test Setup Photo View

Report No.: DG1221220-62768E-02

Signal Port Test Setup Photo

Page 109 of 110

Bay Area Compliance Laboratories Corp. (Dongguan)
CS
Test Setup Photo View

Report No.: DG1221220-62768E-02

Signal Port Test Setup Photo

*****END OF REPORT*****

Page 110 of 110


Acrobat Distiller 11.0 (Windows); modified using iTextSharp 4.1.6 by 1T3XT