iHost-DOC - SONOFF Official
ETSI EN 301 489-1 V2.2.3 (2019-11) ETSI EN 301 489-17 V3.2.4 (2020-09) TEST REPORT For Shenzhen Sonoff Technologies Co.,Ltd. 3F & 6F, Bldg A, No. 663, Bulong Rd, Shenzhen, Guangdong, China Tested Model: AIBridge, AIBridge-26 Report Type: Original Report Product Type: Smart Home Hub Report Number: DG1221220-62768E-02 Report Date: 2023/2/20 Reviewed By: Rocky Xiao RF Engineer Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 TABLE OF CONTENTS DOCUMENT REVISION HISTORY......................................................................................................................... 4 GENERAL INFORMATION ...................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .................................................................................... 5 OBJECTIVE .................................................................................................................................................................. 5 TEST METHODOLOGY.................................................................................................................................................. 5 DECLARATIONS ........................................................................................................................................................... 5 SYSTEM TEST CONFIGURATION ......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION...................................................................................................................... 6 EQUIPMENT MODIFICATIONS....................................................................................................................................... 6 EUT EXERCISE SOFTWARE ......................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS.................................................................................................................... 6 SUPPORT CABLE LIST AND DETAILS............................................................................................................................ 6 BLOCK DIAGRAM OF TEST SETUP ............................................................................................................................... 7 TEST EQUIPMENT LIST ................................................................................................................................................ 8 ENVIRONMENTAL CONDITIONS ................................................................................................................................... 9 SUMMARY OF TEST RESULTS ............................................................................................................................ 10 1 - ENCLOSURE OF ANCILLARY EQUIPMENT MEASURED ON A STAND ALONE BASIS................... 11 MEASUREMENT UNCERTAINTY ................................................................................................................................. 11 TEST SYSTEM SETUP ................................................................................................................................................. 11 EMI TEST RECEIVER AND SPECTRUM ANALYZER SETUP .......................................................................................... 12 TEST PROCEDURE...................................................................................................................................................... 12 CORRECTED AMPLITUDE & MARGIN CALCULATION................................................................................................. 12 TEST DATA................................................................................................................................................................ 13 3 - AC MAINS POWER INPUT/OUTPUT PORTS ................................................................................................ 37 TEST SYSTEM SETUP ................................................................................................................................................. 37 EMI TEST RECEIVER SETUP ...................................................................................................................................... 37 TEST PROCEDURE...................................................................................................................................................... 37 CORRECTED AMPLITUDE & MARGIN CALCULATION................................................................................................. 37 TEST DATA................................................................................................................................................................ 38 5 - VOLTAGE FLUCTUATIONS AND FLICKER (AC MAINS INPUT PORT) ............................................... 50 TEST SYSTEM SETUP ................................................................................................................................................. 50 TEST STANDARD ....................................................................................................................................................... 50 TEST DATA................................................................................................................................................................ 51 6 - WIRED NETWORK PORTS............................................................................................................................... 53 TEST SYSTEM SETUP ................................................................................................................................................. 53 EMI TEST RECEIVER SETUP ...................................................................................................................................... 53 TEST PROCEDURE...................................................................................................................................................... 53 CORRECTED AMPLITUDE & MARGIN CALCULATION................................................................................................. 53 TEST DATA................................................................................................................................................................ 54 7 - RADIO FREQUENCY ELECTROMAGNETIC FIELDS (80 MHZ TO 6 000 MHZ) .................................. 62 TEST SYSTEM SETUP ................................................................................................................................................. 62 TEST LEVEL .............................................................................................................................................................. 62 TEST PROCEDURE...................................................................................................................................................... 63 TEST DATA................................................................................................................................................................ 63 8 - ELECTROSTATIC DISCHARGES.................................................................................................................... 64 TEST SYSTEM SETUP ................................................................................................................................................. 64 TEST LEVEL .............................................................................................................................................................. 64 TEST PROCEDURE...................................................................................................................................................... 64 Page 2 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 TEST DATA................................................................................................................................................................ 65 9 - FAST TRANSIENTS, COMMON MODE.......................................................................................................... 68 TEST SYSTEM SETUP ................................................................................................................................................. 68 TEST LEVEL .............................................................................................................................................................. 68 TEST PROCEDURE...................................................................................................................................................... 68 TEST DATA................................................................................................................................................................ 69 10 - RADIO FREQUENCY, COMMON MODE ..................................................................................................... 70 TEST SYSTEM SETUP ................................................................................................................................................. 70 TEST LEVEL .............................................................................................................................................................. 70 TEST PROCEDURE...................................................................................................................................................... 70 TEST DATA................................................................................................................................................................ 71 12 - VOLTAGE DIPS AND SHORT INTERRUPTIONS....................................................................................... 73 TEST SYSTEM SETUP ................................................................................................................................................. 73 TEST LEVEL AND PERFORMANCE CRITERION ............................................................................................................ 73 TEST PROCEDURE...................................................................................................................................................... 73 TEST DATA................................................................................................................................................................ 74 13 - SURGES ............................................................................................................................................................... 75 TEST SYSTEM SETUP ................................................................................................................................................. 75 TEST LEVEL .............................................................................................................................................................. 75 TEST PROCEDURE...................................................................................................................................................... 75 TEST DATA................................................................................................................................................................ 76 EXHIBITA - EUT PHOTOGRAPHS ....................................................................................................................... 77 CPU BOARD (RV1109) ............................................................................................................................................. 95 EXHIBITB - TEST SETUP PHOTOGRAPHS...................................................................................................... 100 RE ........................................................................................................................................................................... 100 CE_AC ................................................................................................................................................................... 102 CE_ISN .................................................................................................................................................................. 103 FLICKER .................................................................................................................................................................. 104 RS ........................................................................................................................................................................... 105 ESD ........................................................................................................................................................................ 106 EFT ......................................................................................................................................................................... 107 DIPS ........................................................................................................................................................................ 108 SURGE ..................................................................................................................................................................... 109 CS ........................................................................................................................................................................... 110 Page 3 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) DOCUMENT REVISION HISTORY Revision Number 1.0 Report Number DG1221220-62768E-02 Report No.: DG1221220-62768E-02 Description of Revision Original Report Date of Revision 2023/2/20 Page 4 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) GENERAL INFORMATION Report No.: DG1221220-62768E-02 Product Description for Equipment under Test (EUT) Product Name: Test Model: Model Difference: Rated Input Voltage: Serial Number: EUT Received Date: EUT Received Status: Smart Home Hub AIBridge, AIBridge-26 Refer to Dos 5Vdc from USB Sample 1#_AIBridge(RV1109): 1W5O-1 Sample 2#_AIBridge-26(RV1126): 1WYF-2 2023/1/3 Good Objective This report is prepared on behalf of Shenzhen Sonoff Technologies Co.,Ltd. in accordance with ETSI EN 301 489-1 V2.2.3 (2019-11) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility; ETSI EN 301 489-17 V3.2.4 (2020-09) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems; The objective is to determine the compliance of EUT with: ETSI EN 301 489-1 V2.2.3 (2019-11), ETSI EN 301 489-17 V3.2.4 (2020-09). Test Methodology All measurements contained in this report were conducted with ETSI EN 301 489-1 V2.2.3 (2019-11) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility. Declarations BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol "". Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. Otherwise required by the applicant or Product Regulations, Decision Rule in this report did not consider the uncertainty. The extended uncertainty given in this report is obtained by combining the standard uncertainty times the coverage factor K with the 95% confidence interval. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk "". Page 5 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) SYSTEM TEST CONFIGURATION Report No.: DG1221220-62768E-02 Description of Test Configuration The system was configured for testing in a typical fashion (as normally used by a typical user). Test mode: M1: Operating &Wireless Linking M2:OperatingWired Linking&TF Card Working M3:Operating&Wired Linking&USB flash disk Working Note: The chipset RTL8201F works as MCU, the wireless function not used. Equipment Modifications No modification was made to the EUT. EUT Exercise Software No software was used. Support Equipment List and Details Manufacturer SANDisk SanDisk / Lenovo ZIONCOM R&S Heiman Description USB Flash Disk Micro TF Card Antenna Laptop Wireless Router Wideband Radio Communication Tester Zigbee sensor Model 16G UHS-I-16G / E480 MB-R210-00 CMW500 / Serial Number BL201026115 B 9292DVDSV0XZ / PF-1QQYYP 19/06 EMZBWR21103004 149216 / Support Cable List and Details Cable Description RJ45 Cable RJ45 Cable Antenna Cable Shielding Cable Yes No Yes Ferrite Core No No No Length (m) 10 1 10 From Port EUT Wireless Router CMW500 To Wireless Router Laptop Antenna Page 6 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Block Diagram of Test Setup LISN Zigbee Sensor Adapter 10cm EUT Router Laptop U Disk TF Card Report No.: DG1221220-62768E-02 LISN 2 CMW500 Antenna 1.0 Meter 1.5 Meter Non-Conductive Table 80 cm above Ground Plane Page 7 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Test Equipment List Manufacturer R&S TESEQ R&S MICRO-COAX R&S Sunol Sciences R&S Unknown Unknown Unknown Sonoma Farad ETS-Lindgren Agilent Unknown AH Farad E-Microwave EVERFINE EVERFINE HP R&S Werlatone HP Agilent NARDA COM-POWER COM-POWER EM TEST EM TEST EM TEST EM TEST HAEFELY Description Model Serial Number Conducted emission LISN ENV 216 101614 ISN T800 34379 EMI Test Receiver ESCI 100035 Coaxial Cable C-NJNJ-50 C-0200-01 Test Software EMC32 Version 9.10.00 Radiated emissions below 1GHz Antenna JB3 A060611-1 EMI Test Receiver ESR3 102453 Coaxial Cable C-NJNJ-50 C-0075-01 Coaxial Cable C-NJNJ-50 C-0400-01 Coaxial Cable C-NJNJ-50 C-1400-01 Amplifier 310N 372193 Test Software EZ-EMC V1.1.4.2 Radiated emissions above 1GHz Horn Antenna 3115 000 527 35 Spectrum Analyzer E4440A SG43360054 Coaxial Cable C-SJSJ-50 C-0800-01 Preamplifier PAM-0118 469 Test Software EZ-EMC V1.1.4.2 Band-stop Filters OBSF-2400-2483. 5-S OE01601525 Flicker Harmonic & Flicker TEST ING Power Source Harmonic & Flicker Measurement System HFS-4000 HFM3000 P624486CD1411 122 P630850CD1411 115 CS Signal Generator 8648A 3246A00831 Power Amplifier 15A250 12934 Dual Directional Coupler C5091-10 113192 Power Meter 8482A Power sensor Attenuator CDN CDN Ultra Compact Generator Autotransformer CDN EFT Clamp Electrostatic Discharge Simulator HP EPM-441A GB37481494 8482A US37296108 769-6 2754 M325E 521064 T8E 581607 EFT & Surge & Dips UCS 500N5 P1406130994 MV2616 P1450144859 CNV508 S1 311137 N/A 300886 ESD ONYX 180786 RS Calibration Date 2022/10/24 2022/10/24 2022/10/24 2022/9/5 N/A 2020/11/10 2022/10/24 2022/7/19 2022/7/19 2022/7/19 2022/7/18 N/A 2021/10/12 2022/7/15 2022/9/4 2022/10/13 N/A 2022/6/16 2022/4/1 2022/11/16 2022/10/24 N/A 2022/2/9 2023/2/9 2022/7/15 2022/11/18 N/A 2022/7/15 2022/7/15 2022/4/1 N/A 2022/11/22 2022/7/15 2022/10/27 Calibration Due Date 2023/10/23 2023/10/23 2023/10/23 2023/9/4 N/A 2023/11/9 2023/10/23 2023/7/18 2023/7/18 2023/7/18 2023/7/17 N/A 2024/10/11 2023/7/14 2023/9/3 2023/10/12 N/A 2023/6/15 2023/3/31 2023/11/15 2023/10/23 N/A 2023/2/8 2024/2/8 2023/7/14 2023/11/17 N/A 2023/7/14 2023/7/14 2023/3/31 N/A 2023/11/21 2023/7/14 2023/10/26 Page 8 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) AR AR HP AR AR PASTERNACK Agilent Agilent Agilent Antenna Antenna Signal Generator Power Amplifier Power Amplifier Dual Directional Coupler EPM Series Power Meter E-Series Avg Power Sensor E-Series Avg Power Sensor ATL80M1G ATT700M12G 8665B 500W1000C 60S1G6 PE2239-30 E4419B E9301A E9301A Report No.: DG1221220-62768E-02 0351400 0349410 3438a00584 0353561 0348711 1711 MY45103907 MY41497625 MY41497628 N/A N/A 2022/11/18 N/A N/A 2022/7/15 2022/11/18 2022/7/15 2022/7/15 N/A N/A 2023/11/17 N/A N/A 2023/7/14 2023/11/17 2023/7/14 2023/7/14 * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI). Environmental Conditions Test Item: Conducted emission Temperature: Relative Humidity: ATM Pressure: Tester: Test Date: 17.3~20.3 36~38% 101.9~102.1kPa Walker Chen 2023/1/30~2023/2/16 Radiated emissions below 1GHz 19.5~20.1 52~63% 101.8~102.5kPa Leo Yuan 2023/1/17~2023/2/15 Radiated emissions above 1GHz 17.1~21.2 37~44% 101.9~102.3kPa Alan Xie 2023/1/29~2023/2/17 EMS & Flicker 18.1~23.2 40~51% 101.3~101.7kPa Lane Sun 2023/1/31~2023/2/14 Page 9 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) SUMMARY OF TEST RESULTS Report No.: DG1221220-62768E-02 SN Rule and Clause Description of Test 1 EN 301 489 Clause Enclosure of ancillary equipment measured on 8.2 a stand alone basis 2 EN 301 489 Clause 8.3 DC power input/output ports 3 EN 301 489 Clause 8.4 AC mains power input/output ports 4 EN 301 489 Clause Harmonic current emissions (AC mains input 8.5 port) 5 EN 301 489 Clause Voltage fluctuations and flicker (AC mains 8.6 input port) 6 EN 301 489 Clause 8.7 Wired network ports 7 EN 301 489 Clause Radio frequency electromagnetic fields (80 9.2 MHz to 6 000 MHz) 8 EN 301 489 Clause 9.3 Electrostatic discharges 9 EN 301 489 Clause 9.4 Fast transients, common mode 10 EN 301 489 Clause 9.5 Radio frequency, common mode 11 EN 301 489 Clause Transients and surges in the vehicular 9.6 environment 12 EN 301 489 Clause 9.7 Voltage dips and short interruptions 13 EN 301 489 Clause 9.8 Surges Test Result Compliant Not applicable Compliant Not applicable Compliant Compliant Compliant Compliant Compliant Compliant Not applicable Compliant Compliant Note: Not Applicable: Please refer to Applicability overview tables in sections 7.1 and 7.2 of EN 301 489-1 requirements for Radio and ancillary equipment. Page 10 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 1 - ENCLOSURE OF ANCILLARY EQUIPMENT MEASURED ON A STAND ALONE BASIS Measurement Uncertainty Compliance or non- compliance with a disturbance limit shall be determined in the following manner: If Ulab is less than or equal to Ucispr of Table 1, then: -compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit; -non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit. If Ulab is greater than Ucispr of Table 1, then: -compliance is deemed to occur if no measured disturbance level, increased by (Ulab - Ucispr), exceeds the disturbance limit; -non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab - Ucispr), exceeds the disturbance limit. Based on CISPR 16-4-2: 2011, measurement uncertainty of radiated emission at a distance of 10m at Bay Area Compliance Laboratories Corp. (Dongguan) is:30M~200MHz: 4.55 dB for Horizontal, 4.57 dB for Vertical; 200M~1GHz: 4.66 dB for Horizontal, 4.56 dB for Vertical; measurement uncertainty of radiated emission at a distance of 3m at Bay Area Compliance Laboratories Corp. (Dongguan) is:30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical; 200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical; 1G~6GHz: 4.45 dB, 6G~18GHz: 5.23 dB Table 1 - Values of Ucispr Measurement Radiated disturbance (electric field strength at an OATS or in a SAC)(30 MHz to 1000 MHz) Radiated disturbance (electric field strength in a FAR)(1 GHz to 6 GHz) Radiated disturbance (electric field strength in a FAR)(6 GHz to 18 GHz) Ucispr 6.3 dB 5.2 dB 5.5 dB Test System Setup Below 1GHz: Page 11 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Above 1GHz: Report No.: DG1221220-62768E-02 The radiated emission tests below 1GHz were performed in 3 meters, above 1GHz were performed in the 3 meters. The specification used was EN 55032 Class B limits. The external I/O cables were draped along the test table and formed a bundle 30 to 40cm long in the middle. The spacing between the peripherals was 10cm. EMI Test Receiver and Spectrum Analyzer Setup The system was investigated from 30 MHz to 6 GHz. During the radiated emission test, the EMI test receiver(Below 1GHz) and Spectrum Analyzer(Above 1GHz) were set with the following configurations: Frequency Range RBW Video B/W IF B/W Detector 30MHz - 1000 MHz Above 1 GHz 120 kHz 1MHz 1MHz 300 kHz 3 MHz 10Hz 120kHz / / QP Peak Average If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is unnecessary to perform an QP/Average measurement. Test Procedure Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation combinations. All data was recorded in the Quasi-peak detection mode from 30MHz to 1GHz, Peak and average detection mode above 1GHz. Corrected Amplitude & Margin Calculation The basic equation is as follows: Result = Meter Reading+ Corrected Note: Corrected = Antenna Factor + Cable Loss - Amplifier Gain, or Corrected = Antenna Factor + Cable Loss + Insertion loss of attenuator - Amplifier Gain The "Margin" column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows: Margin = Limit-Result Page 12 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Test Data Please refer to following table and plots: Below 1G Condition: Test Mode: Note: EN 301 489 Class B M1: Operating &Wireless Linking RV1109 Report No.: DG1221220-62768E-02 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 30.0000 2 113.4200 3 175.5000 4 350.1000 5 549.9200 6 960.2300 Reading (dBV) 33.13 42.19 43.66 35.84 31.68 28.75 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -11.38 -13.03 -9.52 -5.00 1.57 Result (dBV/m) 29.79 30.81 30.63 26.32 26.68 30.32 Limit (dBV/m) 40.00 40.00 40.00 47.00 47.00 47.00 Margin (dB) 10.21 9.19 9.37 20.68 20.32 16.68 Page 13 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Condition: Test Mode: Note: EN 301 489 Class B M1: Operating &Wireless Linking RV1109 Report No.: DG1221220-62768E-02 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 30.0000 2 42.6100 3 160.9500 4 174.5300 5 649.8300 6 960.2300 Reading (dBV) 35.89 38.64 40.04 45.00 30.07 27.97 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -12.00 -12.26 -12.97 -3.10 1.57 Result (dBV/m) 32.55 26.64 27.78 32.03 26.97 29.54 Limit (dBV/m) 40.00 40.00 40.00 40.00 47.00 47.00 Margin (dB) 7.45 13.36 12.22 7.97 20.03 17.46 Page 14 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1109 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 30.0000 2 155.1300 3 160.9500 4 450.0100 5 904.9400 6 994.1800 Reading (dBV) 32.85 38.58 39.64 34.03 28.31 27.14 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -11.97 -12.26 -6.65 0.68 2.49 Result (dBV/m) 29.51 26.61 27.38 27.38 28.99 29.63 Limit (dBV/m) 40.00 40.00 40.00 47.00 47.00 47.00 Margin (dB) 10.49 13.39 12.62 19.62 18.01 17.37 Page 15 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1109 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 30.0000 2 42.6100 3 174.5300 4 350.1000 5 649.8300 6 960.2300 Reading (dBV) 36.88 37.83 40.57 36.48 29.80 28.79 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -12.00 -12.97 -9.52 -3.10 1.57 Result (dBV/m) 33.54 25.83 27.60 26.96 26.70 30.36 Limit (dBV/m) 40.00 40.00 40.00 47.00 47.00 47.00 Margin (dB) 6.46 14.17 12.40 20.04 20.30 16.64 Page 16 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1109 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 30.0000 2 123.1200 3 350.1000 4 787.5700 5 897.1800 6 960.2300 Reading (dBV) 33.56 31.09 36.91 27.94 27.75 28.66 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -10.84 -9.52 -1.40 0.63 1.57 Result (dBV/m) 30.22 20.25 27.39 26.54 28.38 30.23 Limit (dBV/m) 40.00 40.00 47.00 47.00 47.00 47.00 Margin (dB) 9.78 19.75 19.61 20.46 18.62 16.77 Page 17 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1109 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 30.0000 2 42.6100 3 176.4700 4 350.1000 5 649.8300 6 960.2300 Reading (dBV) 36.00 37.88 33.76 33.55 30.04 28.97 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -12.00 -13.08 -9.52 -3.10 1.57 Result (dBV/m) 32.66 25.88 20.68 24.03 26.94 30.54 Limit (dBV/m) 40.00 40.00 40.00 47.00 47.00 47.00 Margin (dB) 7.34 14.12 19.32 22.97 20.06 16.46 Page 18 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Condition: Test Mode: Note: EN 301 489 Class B M1: Operating &Wireless Linking RV1126 Report No.: DG1221220-62768E-02 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 30.0000 2 450.0100 3 750.7100 4 827.3400 5 850.6200 6 890.3900 Reading (dBV) 34.37 35.35 33.84 32.26 31.70 31.82 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -6.65 -1.99 -0.66 -0.24 0.45 Result (dBV/m) 31.03 28.70 31.85 31.60 31.46 32.27 Limit (dBV/m) 40.00 47.00 47.00 47.00 47.00 47.00 Margin (dB) 8.97 18.30 15.15 15.40 15.54 14.73 Page 19 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Condition: Test Mode: Note: EN 301 489 Class B M1: Operating &Wireless Linking RV1126 Report No.: DG1221220-62768E-02 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 893.3000 2 30.0000 3 106.6300 4 149.3100 5 49.4000 6 827.3400 Reading (dBV) 37.18 37.16 37.67 39.82 41.84 33.22 Detector peak peak peak peak peak peak Corrected (dB/m) 0.54 -3.34 -12.48 -11.74 -16.34 -0.66 Result (dBV/m) 37.72 33.82 25.19 28.08 25.50 32.56 Limit (dBV/m) 47.00 40.00 40.00 40.00 40.00 47.00 Margin (dB) 9.28 6.18 14.81 11.92 14.50 14.44 Page 20 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Condition: Test Mode: Note: EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1126 Report No.: DG1221220-62768E-02 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 30.0000 2 450.0100 3 549.9200 4 649.8300 5 850.6200 6 890.3900 Reading (dBV) 34.37 32.85 31.39 30.98 29.70 28.82 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -6.65 -5.00 -3.10 -0.24 0.45 Result (dBV/m) 31.03 26.20 26.39 27.88 29.46 29.27 Limit (dBV/m) 40.00 47.00 47.00 47.00 47.00 47.00 Margin (dB) 8.97 20.80 20.61 19.12 17.54 17.73 Page 21 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1126 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 30.0000 2 66.8600 3 79.4700 4 149.3100 5 827.3400 6 893.3000 Reading (dBV) 35.66 48.67 47.88 43.82 29.71 30.68 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -16.59 -16.68 -11.74 -0.66 0.54 Result (dBV/m) 32.32 32.08 31.20 32.08 29.05 31.22 Limit (dBV/m) 40.00 40.00 40.00 40.00 47.00 47.00 Margin (dB) 7.68 7.92 8.80 7.92 17.95 15.78 Page 22 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1126 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 30.0000 2 149.3100 3 159.0100 4 549.9200 5 827.3400 6 890.3900 Reading (dBV) 34.87 40.15 40.65 39.39 28.76 28.82 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -11.74 -12.15 -5.00 -0.66 0.45 Result (dBV/m) 31.53 28.41 28.50 34.39 28.10 29.27 Limit (dBV/m) 40.00 40.00 40.00 47.00 47.00 47.00 Margin (dB) 8.47 11.59 11.50 12.61 18.90 17.73 Page 23 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1126 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 30.0000 2 106.6300 3 149.3100 4 750.7100 5 827.3400 6 893.3000 Reading (dBV) 36.66 42.17 41.32 33.02 34.71 35.68 Detector peak peak peak peak peak peak Corrected (dB/m) -3.34 -12.48 -11.74 -1.99 -0.66 0.54 Result (dBV/m) 33.32 29.69 29.58 31.03 34.05 36.22 Limit (dBV/m) 40.00 40.00 40.00 47.00 47.00 47.00 Margin (dB) 6.68 10.31 10.42 15.97 12.95 10.78 Page 24 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Above 1G Condition: Test Mode: Note: EN 301 489 Class B M1: Operating &Wireless Linking RV1109 Report No.: DG1221220-62768E-02 Polarization: Distance: Horizontal 3m Fundamental Frequency No. (MHz) 1 3235.000 2 3235.000 3 3787.500 4 3787.500 5 5197.500 6 5197.500 Reading (dBV) 51.36 39.25 49.56 37.46 49.26 37.57 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -6.59 -6.59 -5.01 -5.01 -1.30 -1.30 Result (dBV/m) 44.77 32.66 44.55 32.45 47.96 36.27 Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Margin (dB) 29.23 21.34 29.45 21.55 26.04 17.73 Page 25 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Condition: Test Mode: Note: EN 301 489 Class B M1: Operating &Wireless Linking RV1109 Report No.: DG1221220-62768E-02 Polarization: Distance: Vertical 3m Fundamental Frequency No. (MHz) 1 1542.500 2 1542.500 3 1710.000 4 1710.000 5 4140.000 6 4140.000 Reading (dBV) 60.68 39.21 55.22 43.68 50.42 38.52 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -12.76 -12.76 -11.80 -11.80 -4.12 -4.12 Result (dBV/m) 47.92 26.45 43.42 31.88 46.30 34.40 Limit (dBV/m) 70.00 50.00 70.00 50.00 74.00 54.00 Margin (dB) 22.08 23.55 26.58 18.12 27.70 19.60 Page 26 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1109 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 2402.500 2 2402.500 3 3310.000 4 3310.000 5 4190.000 6 4190.000 Reading (dBV) 50.85 38.94 50.87 38.63 50.78 38.44 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -9.65 -9.65 -6.16 -6.16 -4.32 -4.32 Result (dBV/m) 41.20 29.29 44.71 32.47 46.46 34.12 Limit (dBV/m) 70.00 50.00 74.00 54.00 74.00 54.00 Margin (dB) 28.80 20.71 29.29 21.53 27.54 19.88 Page 27 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1109 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 1162.500 2 1162.500 3 1332.500 4 1332.500 5 3135.000 6 3135.000 Reading (dBV) 61.83 38.85 57.60 45.26 50.06 38.41 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -14.21 -14.21 -13.61 -13.61 -6.80 -6.80 Result (dBV/m) 47.62 24.64 43.99 31.65 43.26 31.61 Limit (dBV/m) 70.00 50.00 70.00 50.00 74.00 54.00 Margin (dB) 22.38 25.36 26.01 18.35 30.74 22.39 Page 28 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1109 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 2402.500 2 2402.500 3 4305.000 4 4305.000 5 5600.000 6 5600.000 Reading (dBV) 50.74 38.47 49.79 37.59 50.78 38.66 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -9.65 -9.65 -3.76 -3.76 -1.26 -1.26 Result (dBV/m) 41.09 28.82 46.03 33.83 49.52 37.40 Limit (dBV/m) 70.00 50.00 74.00 54.00 74.00 54.00 Margin (dB) 28.91 21.18 27.97 20.17 24.48 16.60 Page 29 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1109 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 1225.000 2 1225.000 3 1917.500 4 1917.500 5 3875.000 6 3875.000 Reading (dBV) 58.89 46.55 49.77 37.64 49.95 37.83 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -14.01 -14.01 -11.17 -11.17 -4.94 -4.94 Result (dBV/m) 44.88 32.54 38.60 26.47 45.01 32.89 Limit (dBV/m) 70.00 50.00 70.00 50.00 74.00 54.00 Margin (dB) 25.12 17.46 31.40 23.53 28.99 21.11 Page 30 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Condition: Test Mode: Note: EN 301 489 Class B M1: Operating &Wireless Linking RV1126 Report No.: DG1221220-62768E-02 Polarization: Distance: Horizontal 3m Fundamental Harmonic spurious emissions Frequency No. (MHz) 1 3205.000 2 3205.000 3 3400.000 4 3400.000 5 5842.500 6 5842.500 Reading (dBV) 52.35 40.57 50.69 38.49 50.64 38.86 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -6.58 -6.58 -5.63 -5.63 0.11 0.11 Result (dBV/m) 45.77 33.99 45.06 32.86 50.75 38.97 Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Margin (dB) 28.23 20.01 28.94 21.14 23.25 15.03 Page 31 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Condition: Test Mode: Note: EN 301 489 Class B M1: Operating &Wireless Linking RV1126 Report No.: DG1221220-62768E-02 Polarization: Distance: Vertical 3m Fundamental Frequency No. (MHz) 1 1767.500 2 1767.500 3 3400.000 4 3400.000 5 3767.500 6 3767.500 Reading (dBV) 50.00 38.25 49.75 37.48 49.82 37.63 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -11.55 -11.55 -5.63 -5.63 -5.07 -5.07 Result (dBV/m) 38.45 26.70 44.12 31.85 44.75 32.56 Limit (dBV/m) 70.00 50.00 74.00 54.00 74.00 54.00 Margin (dB) 31.55 23.30 29.88 22.15 29.25 21.44 Page 32 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Condition: Test Mode: Note: EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1126 Report No.: DG1221220-62768E-02 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 2607.500 2 2607.500 3 3307.500 4 3307.500 5 4087.500 6 4087.500 Reading (dBV) 50.05 38.46 50.43 38.73 50.19 37.51 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -9.28 -9.28 -6.14 -6.14 -3.98 -3.98 Result (dBV/m) 40.77 29.18 44.29 32.59 46.21 33.53 Limit (dBV/m) 70.00 50.00 74.00 54.00 74.00 54.00 Margin (dB) 29.23 20.82 29.71 21.41 27.79 20.47 Page 33 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M2:Operating&Wired Linking&TF Card Working RV1126 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 1365.000 2 1365.000 3 3045.000 4 3045.000 5 4310.000 6 4310.000 Reading (dBV) 56.18 44.74 50.43 38.82 49.53 37.94 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -13.53 -13.53 -7.21 -7.21 -3.77 -3.77 Result (dBV/m) 42.65 31.21 43.22 31.61 45.76 34.17 Limit (dBV/m) 70.00 50.00 74.00 54.00 74.00 54.00 Margin (dB) 27.35 18.79 30.78 22.39 28.24 19.83 Page 34 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1126 Polarization: Distance: Horizontal 3m Frequency No. (MHz) 1 3220.000 2 3220.000 3 4107.500 4 4107.500 5 5170.000 6 5170.000 Reading (dBV) 49.78 37.59 49.64 37.72 50.17 38.42 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -6.58 -6.58 -3.88 -3.88 -1.73 -1.73 Result (dBV/m) 43.20 31.01 45.76 33.84 48.44 36.69 Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Margin (dB) 30.80 22.99 28.24 20.16 25.56 17.31 Page 35 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Condition: Test Mode: Note: EN 301 489 Class B M3:Operating&Wired Linking&USB flash disk Working RV1126 Polarization: Distance: Vertical 3m Frequency No. (MHz) 1 2130.000 2 2130.000 3 3205.000 4 3205.000 5 4302.500 6 4302.500 Reading (dBV) 50.43 38.77 49.99 37.68 49.83 37.54 Detector peak AVG peak AVG peak AVG Corrected (dB/m) -10.47 -10.47 -6.58 -6.58 -3.76 -3.76 Result (dBV/m) 39.96 28.30 43.41 31.10 46.07 33.78 Limit (dBV/m) 70.00 50.00 74.00 54.00 74.00 54.00 Margin (dB) 30.04 21.70 30.59 22.90 27.93 20.22 Page 36 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) 3 - AC MAINS POWER INPUT/OUTPUT PORTS Test System Setup Report No.: DG1221220-62768E-02 The setup of EUT is according with per EN 301 489-1 measurement procedures. The specification used was with the EN 301 489-1 limits. The external I/O cables were draped along the test table and formed a bundle 30 to 40cm long in the middle. The spacing between the peripherals was 10cm. The adapter was connected to AC230V/50Hz power source. EMI Test Receiver Setup The EMI test receiver was set to investigate the spectrum from 150 kHz to 30MHz. During the conducted emission test, the EMI test receiver was set with the following configurations: Frequency Range 150 kHz - 30 MHz IF B/W 9 kHz Test Procedure During the conducted emissions test, the adapter was connected to the main outlet of the first LISN and the other support equipments were connected to the outlet of the second LISN. Maximizing procedure was performed on the six (6) highest emissions of the EUT. All data was recorded in the Quasi-peak and average detection mode. Corrected Amplitude & Margin Calculation The basic equation is as follows: Result (QuasiPeak or Average) = Meter Reading + Corr. Note: Corr. = Cable loss + Factor of coupling device The "Margin" column of the following data tables indicates the degree of compliance within the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows: Margin = Limit -Result Page 37 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Test Data Please refer to following table and plots: RV1109 Port: Test Mode: L M1: Operating & Wireless Linking Power Source: Note: AC 230V/50Hz Report No.: DG1221220-62768E-02 Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.421178 --- 0.683241 36.36 0.686657 --- 0.781732 --- 0.805479 30.79 1.373481 29.60 1.387250 --- 2.562008 30.06 3.255003 --- 4.346933 --- 4.412464 28.94 11.439286 27.20 Average (dBV) 20.77 --- 28.78 23.43 ----20.73 --19.83 19.14 ----- Limit (dBV) 47.42 56.00 46.00 46.00 56.00 56.00 46.00 56.00 46.00 46.00 56.00 60.00 Margin (dB) 26.65 19.64 17.22 22.57 25.21 26.40 25.27 25.94 26.17 26.86 27.06 32.80 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 Corr. (dB) 9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 10.0 Page 38 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: N M1: Operating & Wireless Linking AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.199323 31.68 0.301537 30.34 0.421178 --- 0.686657 --- 0.686657 33.72 0.903386 --- 0.926198 28.41 1.415204 --- 1.415204 25.68 2.151633 --- 4.523884 --- 11.611735 24.58 Average (dBV) ----21.32 29.89 --24.63 --20.38 --20.33 18.81 --- Limit (dBV) 63.64 60.20 47.42 46.00 56.00 46.00 56.00 46.00 56.00 46.00 46.00 60.00 Margin (dB) 31.96 29.86 26.10 16.11 22.28 21.37 27.59 25.62 30.32 25.67 27.19 35.42 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line N N N N N N N N N N N N Corr. (dB) 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.8 Page 39 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: L M2: Operating Wired Linking&TF Card Working AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.350205 0.683241 0.686657 0.805479 0.805479 1.373481 1.472813 2.562008 2.639835 4.368668 4.390511 11.553965 ----36.36 --30.39 29.76 ----29.32 --28.35 30.52 Average (dBV) 21.80 28.84 --23.66 ----21.22 20.18 --19.93 ----- Limit (dBV) 48.96 46.00 56.00 46.00 56.00 56.00 46.00 46.00 56.00 46.00 56.00 60.00 Margin (dB) 27.16 17.16 19.64 22.34 25.61 26.24 24.78 25.82 26.68 26.07 27.65 29.48 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 Corr. (dB) 9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 10.0 Page 40 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: N M2: Operating Wired Linking&TF Card Working AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.200319 0.298544 0.416998 0.683241 0.690091 0.903386 0.978432 1.436538 1.480177 2.437361 3.222695 4.478982 31.95 29.30 --33.36 ----26.50 25.00 --22.81 ----- Average (dBV) ----20.63 --29.92 24.12 ----20.38 --19.80 19.42 Limit (dBV) 63.60 60.28 47.51 56.00 46.00 46.00 56.00 56.00 46.00 56.00 46.00 46.00 Margin (dB) 31.65 30.98 26.88 22.64 16.08 21.88 29.50 31.00 25.62 33.19 26.20 26.58 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line N N N N N N N N N N N N Corr. (dB) 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 Page 41 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: L M3: Operating & USB flash disk Working AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.427528 0.686657 0.686657 0.809506 0.829947 1.287253 1.465485 2.562008 2.574818 4.282376 4.802907 7.122346 ----39.46 --34.31 33.62 ----34.06 --34.23 41.38 Average (dBV) 24.65 31.15 --26.47 ----24.80 23.79 --23.42 ----- Limit (dBV) 47.30 46.00 56.00 46.00 56.00 56.00 46.00 46.00 56.00 46.00 56.00 60.00 Margin (dB) 22.65 14.85 16.54 19.53 21.69 22.38 21.20 22.21 21.94 22.58 21.77 18.62 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 Corr. (dB) 9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.8 Page 42 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: N M3: Operating & USB flash disk Working AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.429665 0.686657 0.693541 0.926198 0.978432 1.380348 1.465485 2.562008 3.255003 4.456698 4.924186 6.809708 --35.77 ----32.79 --30.37 30.51 ----29.63 37.06 Average (dBV) 24.42 --- 33.24 26.72 --25.15 ----23.19 22.40 ----- Limit (dBV) 47.26 56.00 46.00 46.00 56.00 46.00 56.00 56.00 46.00 46.00 56.00 60.00 Margin (dB) 22.84 20.23 12.76 19.28 23.21 20.85 25.63 25.49 22.81 23.60 26.37 22.94 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line N N N N N N N N N N N N Corr. (dB) 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 Page 43 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 RV1126 Port: Test Mode: Power Source: Note: L M1: Operating &Wireless Linking AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.343287 0.683241 0.686657 0.809506 0.921590 1.401157 2.077810 2.679631 3.304072 4.501377 4.523884 11.269399 --37.97 ----32.21 --31.00 --31.33 --30.96 33.37 Average (dBV) 24.43 --- 31.32 25.37 --22.72 --22.18 --22.05 ----- Limit (dBV) 49.12 56.00 46.00 46.00 56.00 46.00 56.00 46.00 56.00 46.00 56.00 60.00 Margin (dB) 24.69 18.03 14.68 20.63 23.79 23.28 25.00 23.82 24.67 23.95 25.04 26.63 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 Corr. (dB) 9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 10.0 Page 44 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: N M1: Operating &Wireless Linking AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.218045 0.431814 0.686657 0.686657 0.912443 1.075686 1.353083 1.487578 2.613633 3.387504 4.501377 11.964470 32.02 ----- 35.18 --- 27.92 27.37 --25.80 ----29.87 Average (dBV) --22.77 31.87 --25.25 ----23.00 --22.38 21.63 --- Limit (dBV) 62.89 47.22 46.00 56.00 46.00 56.00 56.00 46.00 56.00 46.00 46.00 60.00 Margin (dB) 30.87 24.45 14.13 20.82 20.75 28.08 28.63 23.00 30.20 23.62 24.37 30.13 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line N N N N N N N N N N N N Corr. (dB) 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.8 Page 45 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: L M2:Operating&Wired Linking&TF Card Working AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.309151 0.683241 0.683241 0.829947 0.926198 1.380348 2.077810 2.140929 2.653034 4.546503 4.569236 10.098279 ----37.53 --32.06 --31.82 --31.79 31.15 --33.97 Average (dBV) 23.34 30.08 --24.98 --22.29 --21.93 ----20.45 --- Limit (dBV) 49.99 46.00 56.00 46.00 56.00 46.00 56.00 46.00 56.00 56.00 46.00 60.00 Margin (dB) 26.65 15.92 18.47 21.02 23.94 23.71 24.18 24.07 24.21 24.85 25.55 26.03 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 Corr. (dB) 9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.9 Page 46 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: N M2:Operating&Wired Linking&TF Card Working AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.427528 0.683241 0.686657 0.930829 1.023352 1.249302 1.387250 2.562008 3.370651 4.592082 10.098279 10.667780 ----34.77 --28.94 27.20 --25.95 ----32.26 30.56 Average (dBV) 22.38 31.28 --25.13 ----22.37 --22.29 22.13 ----- Limit (dBV) 47.30 46.00 56.00 46.00 56.00 56.00 46.00 56.00 46.00 46.00 60.00 60.00 Margin (dB) 24.92 14.72 21.23 20.87 27.06 28.80 23.63 30.05 23.71 23.87 27.74 29.44 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line N N N N N N N N N N N N Corr. (dB) 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.7 9.7 Page 47 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: L M3:Operating&Wired Linking&USB flash disk Working AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.431814 0.683241 0.686657 0.801471 0.805479 1.415204 2.077810 2.720027 2.720027 4.478982 4.478982 10.048039 --38.09 --32.37 ----32.34 33.36 --32.20 --35.59 Average (dBV) 22.99 --- 31.33 --- 26.02 22.85 ----23.17 --22.50 --- Limit (dBV) 47.22 56.00 46.00 56.00 46.00 46.00 56.00 56.00 46.00 56.00 46.00 60.00 Margin (dB) 24.23 17.91 14.67 23.63 19.98 23.15 23.66 22.64 22.83 23.80 23.50 24.41 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 Corr. (dB) 9.6 9.6 9.6 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.9 Page 48 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: N M3:Operating&Wired Linking&USB flash disk Working AC 230V/50Hz Level in dB 80 70 60 50 40 30 20 10 0 150k Class B Voltage on Mains QP Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.431814 0.686657 0.690091 0.926198 1.008154 1.300158 1.487578 2.140929 2.574818 4.478982 4.546503 8.068162 --35.98 ----29.95 27.96 ----28.52 26.77 --32.97 Average (dBV) 24.16 --- 32.65 26.34 ----24.03 23.95 ----23.47 --- Limit (dBV) 47.22 56.00 46.00 46.00 56.00 56.00 46.00 46.00 56.00 56.00 46.00 60.00 Margin (dB) 23.06 20.02 13.35 19.66 26.05 28.04 21.97 22.05 27.48 29.23 22.53 27.03 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line N N N N N N N N N N N N Corr. (dB) 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.6 9.7 Page 49 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 5 - VOLTAGE FLUCTUATIONS AND FLICKER (AC MAINS INPUT PORT) Test System Setup AC Mains AC Source Analyzer EUT System Wooden Table 80cm Test Standard EN 61000-3-3:2013+A1:2019+A2:2021 Flicker Test Limits: The limits shall be applicable to voltage fluctuations and flicker at the supply terminals of the equipment under test, measured or calculated according to clause 4 under test conditions described in clause 6 and annex A. Tests made to prove compliance with the limits are considered to be type tests. The following limits apply: - the value of Pst shall not be greater than 1,0; - the value of Plt shall not be greater than 0,65; - the value of d(t) during a voltage change shall not exceed 3,3 % for more than 500 ms; - the relative steady-state voltage change, dc, shall not exceed 3,3 %; - the maximum relative voltage change dmax, shall not exceed a) 4 % without additional conditions; b) 6 % for equipment which is: switched manually, or - switched automatically more frequently than twice per day, and also has either adelayed restart (the delay being not less than a few tens of seconds), or manual restart, after a power supply interruption. Note: The cycling frequency will be further limited by the Pst and Plt limit. For example: a dmax of 6 % producing a rectangular voltage change characteristic twice per hour will give a Plt of about 0,65. c) 7 % for equipment which is - attended whilst in use (for example: hair dryers, vacuum cleaners, kitchen equipment such as mixers, garden equipment such as lawn mowers, portable tools such as electric drills), or - switched on automatically, or is intended to be switched on manually, no more than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds) or manual restart, after a power supply interruption. In the case of equipment having several separately controlled circuits in accordance with 6.6,limits b) and c) shall apply only if there is delayed or manual restart after a power supply interruption; for all equipment with automatic switching which is energized immediately on restoration of supply after a power supply interruption, limits a) shall apply; for all equipment with manual switching, limits b) or c) shall apply depending on the rate of switching. Pst and Plt requirements shall not be applied to voltage changes caused by manual switching. The limits shall not be applied to voltage changes associated with emergency switching or emergency interruptions. Page 50 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Test Data Report No.: DG1221220-62768E-02 Please refer to following tables: RV1109 Short time (Pst): Observation time: Test Mode: Power Source: Test Result 10 min 120 min (12 Flicker measurement) M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working AC 230V/50Hz PASS Maximum Flicker resultsM1 Pst Plt dc [%] dmax [%] dt [s] EUT values 0.028 0.028 0.012 0.253 0.000 Limit 1.00 0.65 3.30 4.00 0.50 Result PASS PASS PASS PASS PASS Maximum Flicker resultsM2 Pst Plt dc [%] dmax [%] dt [s] EUT values 0.028 0.028 0.016 0.224 0.000 Limit 1.00 0.65 3.30 4.00 0.50 Result PASS PASS PASS PASS PASS Maximum Flicker resultsM3 Pst Plt dc [%] dmax [%] dt [s] EUT values 0.028 0.028 0.015 0.213 0.000 Limit 1.00 0.65 3.30 4.00 0.50 Result PASS PASS PASS PASS PASS Page 51 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) RV1126 Short time (Pst): Observation time: Test Mode: Power Source: Test Result 10 min 120 min (12 Flicker measurement) M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working AC 230V/50Hz PASS Maximum Flicker results (M1) Report No.: DG1221220-62768E-02 Pst Plt dc [%] dmax [%] dt [s] EUT values 0.028 0.028 0.013 0.221 0.000 Limit 1.00 0.65 3.30 4.00 0.50 Result PASS PASS PASS PASS PASS Maximum Flicker results (M2) Pst Plt dc [%] dmax [%] dt [s] EUT values 0.028 0.028 0.015 0.236 0.000 Limit 1.00 0.65 3.30 4.00 0.50 Result PASS PASS PASS PASS PASS Maximum Flicker results (M3) Pst Plt dc [%] dmax [%] dt [s] EUT values 0.028 0.028 0.015 0.241 0.000 Limit 1.00 0.65 3.30 4.00 0.50 Result PASS PASS PASS PASS PASS Page 52 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) 6 - WIRED NETWORK PORTS Test System Setup Report No.: DG1221220-62768E-02 The setup of EUT is according with per EN 301 489-1 measurement procedures. The specification used was with the EN 301 489-1 limits. The external I/O cables were draped along the test table and formed a bundle 30 to 40cm long in the middle. The spacing between the peripherals was 10cm. EMI Test Receiver Setup The EMI test receiver was set to investigate the spectrum from 150 kHz to 30MHz During the conducted emission test, the EMI test receiver was set with the following configurations: Frequency Range 150 kHz - 30 MHz IF B/W 9 kHz Test Procedure During the conducted emissions test, the adapter was connected to the main outlet of the first LISN and the other support equipments were connected to the outlet of the second LISN. Maximizing procedure was performed on the six (6) highest emissions of the EUT. All data was recorded in the Quasi-peak and average detection mode. Corrected Amplitude & Margin Calculation The basic equation is as follows: Result (QuasiPeak or Average) = Meter Reading + Corr. Note: Corr. = Cable loss + Factor of coupling device The "Margin" column of the following data tables indicates the degree of compliance within the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows: Margin = Limit -Result Page 53 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Test Data Please refer to following table and plots: RV1109 Port: RJ45 Test Mode: 10Mbps Power Source: AC 230V/50Hz Note: M2: Operating Wired Linking&TF Card Working 100 80 Class B Voltage on Telcom QP Class B Voltage on Telcom Average 60 Level in dB 40 20 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.260930 0.429665 59.65 --- 0.429665 0.511614 0.543169 0.663098 0.666413 0.881136 1.023352 1.366648 13.418776 16.963591 60.74 59.88 ----58.33 57.88 --55.34 ----- Average (dBV) --51.60 ----51.30 51.76 ----49.57 --51.48 48.85 Limit (dBV) 79.40 65.26 75.26 74.00 64.00 64.00 74.00 74.00 64.00 74.00 64.00 64.00 Margin (dB) 19.75 13.66 14.52 14.12 12.70 12.24 15.67 16.12 14.43 18.66 12.52 15.15 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Corr. (dB) 9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6 9.6 Page 54 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: RJ45 100Mbps AC 230V/50Hz M2: Operating Wired Linking&TF Card Working 100 80 Class B Voltage on Telcom QP Class B Voltage on Telcom Average 60 Level in dB 40 20 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.301537 0.419083 0.419083 0.509069 0.527156 0.666413 0.666413 1.018261 1.153481 1.280849 13.418776 16.963591 60.40 --- 60.63 --- 59.91 58.98 ----56.79 55.21 ----- Average (dBV) --51.88 --51.00 ----51.67 49.86 ----51.46 48.74 Limit (dBV) 78.20 65.47 75.47 64.00 74.00 74.00 64.00 64.00 74.00 74.00 64.00 64.00 Margin (dB) 17.80 13.59 14.84 13.00 14.09 15.02 12.33 14.14 17.21 18.79 12.54 15.26 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Corr. (dB) 9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6 9.6 Page 55 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: RJ45 10Mbps AC 230V/50Hz M3: Operating & USB flash disk Working 100 80 Class B Voltage on Telcom QP Class B Voltage on Telcom Average 60 Level in dB 40 20 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.303044 0.406728 0.423284 0.453897 0.537778 0.659799 0.663098 0.881136 1.023352 1.268136 13.418776 16.963591 60.30 --- 60.59 59.71 --58.75 --57.79 --56.10 ----- Average (dBV) --51.45 ----50.45 --50.98 --50.14 --51.40 48.98 Limit (dBV) 78.16 65.71 75.38 74.80 64.00 74.00 64.00 74.00 64.00 74.00 64.00 64.00 Margin (dB) 17.86 14.26 14.79 15.09 13.55 15.25 13.02 16.21 13.86 17.90 12.60 15.02 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Corr. (dB) 9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6 9.6 Page 56 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: RJ45 100Mbps AC 230V/50Hz M3: Operating & USB flash disk Working 100 80 Class B Voltage on Telcom QP Class B Voltage on Telcom Average 60 Level in dB 40 20 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.292647 0.386939 0.429665 0.551358 0.551358 0.656516 0.663098 1.023352 1.023352 1.268136 13.418776 24.536148 60.73 60.35 ----58.99 59.04 --57.31 --56.59 ----- Average (dBV) ----52.26 51.08 ----52.10 --50.43 --51.78 49.14 Limit (dBV) 78.45 76.13 65.26 64.00 74.00 74.00 64.00 74.00 64.00 74.00 64.00 64.00 Margin (dB) 17.72 15.78 13.00 12.92 15.01 14.96 11.90 16.69 13.57 17.41 12.22 14.86 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Corr. (dB) 9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6 9.8 Page 57 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 RV1126 Port: Test Mode: Power Source: Note: RJ45 10Mbps AC 230V/50Hz M2:Operating&Wired Linking&TF Card Working 100 80 Class B Voltage on Telcom QP Class B Voltage on Telcom Average 60 Level in dB 40 20 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.301537 0.412859 0.423284 0.516743 0.516743 0.659799 0.659799 0.881136 0.894420 1.332988 1.332988 9.998049 --60.94 --60.12 --59.11 --57.89 --56.12 --57.31 Average (dBV) 53.89 --- 54.28 --- 52.92 --- 52.82 --- 50.94 --- 48.66 --- Limit (dBV) 68.20 75.59 65.38 74.00 64.00 74.00 64.00 74.00 64.00 74.00 64.00 74.00 Margin (dB) 14.31 14.65 11.10 13.88 11.08 14.89 11.18 16.11 13.06 17.88 15.34 16.69 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Corr. (dB) 9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.7 9.6 Page 58 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: RJ45 100Mbps AC 230V/50Hz M2:Operating&Wired Linking&TF Card Working 100 80 Class B Voltage on Telcom QP Class B Voltage on Telcom Average 60 Level in dB 40 20 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.292647 0.297058 0.406728 0.421178 0.504016 0.527156 0.656516 0.659799 0.898892 1.013195 1.373481 17.831112 61.40 --- 60.75 --- 59.60 --- 60.84 --- 57.76 ----- 58.20 Average (dBV) --52.32 --52.41 --51.45 --52.04 --49.23 47.18 --- Limit (dBV) 78.45 68.32 75.71 65.42 74.00 64.00 74.00 64.00 74.00 64.00 64.00 74.00 Margin (dB) 17.05 16.00 14.96 13.01 14.40 12.55 13.16 11.96 16.24 14.77 16.82 15.80 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Corr. (dB) 9.9 9.9 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.7 9.6 Page 59 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: RJ45 10Mbps AC 230V/50Hz M3:Operating&Wired Linking&USB flash disk Working 100 80 Class B Voltage on Telcom QP Class B Voltage on Telcom Average 60 Level in dB 40 20 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.303044 0.392773 0.429665 0.516743 0.537778 0.640347 0.650000 0.894420 0.903386 1.249302 1.339653 9.998049 --59.77 --58.89 --58.57 ----56.22 55.42 --57.18 Average (dBV) 52.80 --- 53.00 --- 52.27 --- 52.07 49.67 ----47.41 --- Limit (dBV) 68.16 76.00 65.26 74.00 64.00 74.00 64.00 64.00 74.00 74.00 64.00 74.00 Margin (dB) 15.36 16.23 12.26 15.11 11.73 15.43 11.93 14.33 17.78 18.58 16.59 16.82 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Corr. (dB) 9.9 9.8 9.8 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 9.6 Page 60 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Port: Test Mode: Power Source: Note: RJ45 100Mbps AC 230V/50Hz M3:Operating&Wired Linking&USB flash disk Working 100 80 Class B Voltage on Telcom QP Class B Voltage on Telcom Average 60 Level in dB 40 20 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Final_Result Frequency QuasiPeak (MHz) (dBV) 0.300036 0.303044 0.390819 0.390819 0.438323 0.554114 0.633991 0.640347 0.885542 0.903386 1.249302 1.255549 --59.06 --59.49 --58.75 --58.51 56.49 ----54.89 Average (dBV) 50.62 --- 50.60 --- 50.36 --- 50.13 ----- 48.24 46.18 --- Limit (dBV) 68.24 78.16 66.05 76.05 65.09 74.00 64.00 74.00 74.00 64.00 64.00 74.00 Margin (dB) 17.62 19.10 15.45 16.56 14.73 15.25 13.87 15.49 17.51 15.76 17.82 19.11 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 Line Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Corr. (dB) 9.9 9.9 9.8 9.8 9.8 9.8 9.8 9.8 9.7 9.7 9.7 9.7 Page 61 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 7 - RADIO FREQUENCY ELECTROMAGNETIC FIELDS (80 MHZ TO 6 000 MHZ) Test System Setup Anechoic Chamber 3m Power Amplifier Signal Generator EUT System Wooden table 80 cm Test Level Level 1. 2. 3. X. Field Strength V/m 1 3 10 Special Performance Criterion: A General Performance Criteria: A. The apparatus shall continue to operate as intended during and after the test. The manufacturer specifies some minimum performance level. The performance level may be specified by the manufacture as a permissible loss of performance. B. The apparatus shall continue to operate as intended after the test. This indicates that the EUT does not need to function at normal performance levels during the test, but must recover. Again some minimal performance is defined by the manufacture. No change in operating state or loss or data is permitted. C. Temporary loss of function is allowed. Operation of the EUT may stop as long as it is either automatically reset or can be manually restored by operation of the controls. D. The apparatus is broken, cannot be normal operated. Page 62 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above the ground. The EUT is set 3 meters away from the antenna which is mounted on an antenna tower. Both horizontal and vertical polarizations of the antenna are set on test. Each of the four sides of EUT must be faced this antenna and measured individually. Test Data Please refer to following tables: Test Mode: Note: M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working Condition of Test Field Strength RF Signal Sweep Frequency Step Dwell Time 3 V/m (Test Level 2) 1 kHz, 80% AM, sine wave 1%, logarithmic 1 Sec Remarks RV1109 Frequency Range (MHz) 80-1000 1000-6000 Front Side VERT HORI A A A A Rear Side VERT HORI A A A A Left Side VERT HORI A A A A Right Side VERT HORI A A A A RV1126 Frequency Range (MHz) 80-1000 1000-6000 Front Side VERT HORI A A A A Rear Side VERT HORI A A A A Left Side VERT HORI A A A A Right Side VERT HORI A A A A Note: "A" stand for, during test, operate as intended no loss of function, no degradation of performance, no unintentional transmissions and after test, no degradation of performance, no loss of function, no loss of stored data or user programmable functions. Page 63 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) 8 - ELECTROSTATIC DISCHARGES Report No.: DG1221220-62768E-02 Test System Setup Adapter AC Mains EUT System Wooden Table ESD Tester 80 cm Remark: is the tip of the electrode EN61000-4-2 specifies that a tabletop EUT shall be placed on a non-conducting table which is 80 centimeters above a ground reference plane and that floor mounted equipment shall be placed on a insulating support approximately 10 centimeters above a ground plane. During the tests, the EUT is positioned over a ground reference plane in conformance with this requirement. For tabletop equipment, a 1.6 by 0.8-meter metal sheet (HCP) is placed on the table and connected to the ground plane via a metal strap with two 470 k Ohms resistors in series. The EUT and attached cables are isolated from this metal sheet by 0.5-millimeter thick insulating material. A Vertical Coupling Plane (VCP) grounded on the ground plane through the same configuration as in the HCP is used. Test Level Level 1. Test Voltage Contact Discharge (±kV) 2 2. 4 3. 6 4. 8 X. Special Test Level 3 for Air Discharge at ±8 kV Test Level 2 for Direct Discharge at ±4 kV Test Voltage Air Discharge (±kV) 2 4 8 15 Special Performance criterion: B Test Procedure Air Discharge: This test is done on a non-conductive surface. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed. Contact Discharge: All the procedure shall be same as Section 8.3.1 of EN 61000-4-2, except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. Indirect discharge for horizontal coupling plane At least 50 single discharges shall be applied to the horizontal coupling plane, at points on each side of the EUT. The discharge electrode positions vertically at a distance of 0.1m from the EUT and with the discharge electrode touching the coupling plane. Indirect discharge for vertical coupling plane At least 50 single discharges shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated. Page 64 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Test Data Please refer to following tables: RV1109 Test Mode: Note: M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working Table 1: Electrostatic Discharge Immunity (Air Discharge) Test Points Location Non-metallic Shell USB Port TF card Port RJ45 USB Cable Reticle Button Seam Test Level -2 kV A +2 kV A -4 kV A +4 kV A -8 kV A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Table 2: Electrostatic Discharge Immunity (Direct Contact) Test Points Location / -2 kV / +2 kV / -4 kV / Test Level +4 kV -6 kV / / Table 3: Electrostatic Discharge Immunity (Indirect Contact HCP) Test Points Location Front Side Back Side Left Side Right Side Test Level -2 kV A +2 kV A -4 kV A +4 kV A -6 kV / A A A A / A A A A / A A A A / Table 4: Electrostatic Discharge Immunity (Indirect Contact VCP) Test Points Location Front Side Back Side Left Side Right Side Test Level -2 kV +2 kV -4 kV +4 kV -6 kV A A A A / A A A A / A A A A / A A A A / +8 kV A A A A A A A A +6 kV / +6 kV / / / / +6 kV / / / / -15 kV / / / / / / / / +15 kV / / / / / / / / -8 kV / +8 kV / -8 kV / / / / +8 kV / / / / -8 kV / / / / +8 kV / / / / Page 65 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) ESD Location Photo Report No.: DG1221220-62768E-02 Air Discharge: Direct Contact: RV1126 Test Mode: Note: M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working Table 1: Electrostatic Discharge Immunity (Air Discharge) Test Points Location Non-metallic Shell USB Port TF card Port RJ45 USB Cable Reticle Button Seam Test Level -2 kV A +2 kV A -4 kV A +4 kV A -8 kV A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A +8 kV A A A A A A A A -15 kV / / / / / / / / +15 kV / / / / / / / / Page 66 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Table 2: Electrostatic Discharge Immunity (Direct Contact) Test Points Location / -2 kV / +2 kV / -4 kV / Test Level +4 kV -6 kV / / +6 kV / -8 kV / +8 kV / Table 3: Electrostatic Discharge Immunity (Indirect Contact HCP) Test Points Location Front Side -2 kV A +2 kV A -4 kV A Test Level +4 kV -6 kV A / +6 kV / -8 kV / +8 kV / Back Side A A A A / / / / Left Side A A A A / / / / Right Side A A A A / / / / Table 4: Electrostatic Discharge Immunity (Indirect Contact VCP) Test Points Location -2 kV +2 kV -4 kV Test Level +4 kV -6 kV +6 kV -8 kV +8 kV Front Side A A A A / / / / Back Side A A A A / / / / Left Side A A A A / / / / Right Side A A A A / / / / ESD Location Photo Air Discharge: Direct Contact: Page 67 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) 9 - FAST TRANSIENTS, COMMON MODE Test System Setup Ground Reference Plane Report No.: DG1221220-62768E-02 EUT Wooden Table 80cm 10cm Grounding Cable Test Level Ground Reference Plane Level 1 2 3 4 X Open Circuit Output Test Voltage ±10 On Power Supply Lines 0.5 kV 1 kV 2 kV 4 kV Special On I/O (Input/Output) Signal data and control lines 0.25 kV 0.5 kV 1 kV 2 kV Special Performance Criterion: B Test Procedure The EUT was arranged for Power Line Coupling and for I/O Line Coupling through a capacitive clamp, where applicable. (Note: The I/O coupling test using a capacitive clamp is performed on the I/O interface cables that are longer in length than 3 meters.) A metal ground plane 2.4 meter by 2.0 meter was placed between the floor and the table and is connected to the earth by a 2.0 meter ground rod. The ground rod is connected to the test facility's electrical earth. Page 68 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Test Data Please refer to following tables: RV1109 Test Mode: Note: M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working Test Points L N AC mains power input ports Earth L+N L + Earth N + Earth L+N+Earth Signal ports RJ45 Test Level (kV) +0.5 -0.5 +1.0 -1.0 +2.0 -2.0 +4.0 -4.0 A A A A / / / / A A A A / / / / / / / / / / / / A A A A / / / / / / / / / / / / / / / / / / / / / / / / / / / / A A / / / / / / RV1126 Test Mode: Note: M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working Test Points L N Earth AC mains power L+N input ports L + Earth N + Earth L+N+Earth Signal ports RJ45 Test Level (kV) +0.5 -0.5 +1.0 -1.0 +2.0 -2.0 +4.0 -4.0 A A A A / / / / A A A A / / / / / / / / / / / / A A A A / / / / / / / / / / / / / / / / / / / / / / / / / / / / A A / / / / / / Page 69 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) 10 - RADIO FREQUENCY, COMMON MODE Test System Setup Report No.: DG1221220-62768E-02 EUT SG CDN Wooden Table 10 cm Test Level Level 1 2 3 X Voltage Level (r.m.s.) (U0) 1 3 10 Special Performance Criterion: A Test Procedure 1)Let the EUT work in test mode and test it. 2)The EUT are placed on an insulating support 0.1 m high above a ground reference plane. CDN (coupling and decoupling device) is placed on the ground plane about 0.3 m from EUT. Cables between CDN and EUT are as short as possible, and their height above the ground reference plane shall be between 30 and 50 mm (where possible). 3)The disturbance signal described below is injected to EUT through CDN. 4)The EUT operates within its operational mode(s) under intended climatic conditions after power on. 5)The frequency range is swept from 150 kHz to 80 MHz using 3V signal level, and with the disturbance signal 80% amplitude modulated with a 1 kHz sine wave. 6) Where the frequency is swept incrementally, the step size shall not exceed 1 % of the preceding frequency value. The dwell time of the amplitude modulated carrier at each frequency shall not be less than the time necessary for the EUT to be exercised and to respond, but shall in no case be less than 0.5 s. 7) Recording the EUT operating situation during compliance testing and decide the EUT immunity criterion. Page 70 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Test Data Please refer to following tables: RV1109 Test Mode: Note: M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working Table 1: AC mains power input port Frequency range:150kHz to80MHz Modulated: Amplitude 80%, 1kHz sine wave Severity Level: 3V Unmodulated , r.m.s Unmodulated Other: Level Voltage Level (e.m.f.) U0 Pass Fail 1 1 / / 2 3 A / 3 10 / / X Special / / Table 2: Signal Port :____RJ45___ Frequency range: 150 kHz to80MHz Modulated: Amplitude 80%, 1kHz sine wave Severity Level: 3 V Unmodulated , r.m.s Unmodulated Other: Level Voltage Level (e.m.f.) U0 Pass Fail 1 1 / / 2 3 A / 3 10 / / X Special / / Page 71 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 RV1126 Test Mode: Note: M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working Table 1: AC mains power input port Frequency range:150kHz to80MHz Modulated: Amplitude 80%, 1kHz sine wave Severity Level: 3V Unmodulated , r.m.s Unmodulated Other: Level Voltage Level (e.m.f.) U0 Pass Fail 1 1 / / 2 3 A / 3 10 / / X Special / / Table 2: Signal Port :____RJ45___ Frequency range: 150 kHz to80MHz Modulated: Amplitude 80%, 1kHz sine wave Severity Level: 3 V Unmodulated , r.m.s Unmodulated Other: Level Voltage Level (e.m.f.) U0 Pass Fail 1 1 / / 2 3 A / 3 10 / / X Special / / Page 72 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 12 - VOLTAGE DIPS AND SHORT INTERRUPTIONS Test System Setup Ground Reference Plane EUT Wooden Table 80cm 10cm Grounding Cable Test Level and Performance Criterion Ground Reference Plane Test Level 1 2 3 4 Voltage dip and short interruptions (% ) Residual 0 0 70 0 Duration (in period) 0.5 1 25 250 Performance criterion B B C C Test Procedure 1) The interruption is introduced at selected phase angles with specified duration. 2) Record any degradation of performance. Page 73 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Test Data Please refer to following tables: RV1109 Test Mode: Note: M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working B indicates that the power supply of the EUT was interrupted during the test, and the EUT was restarted. After the test, it can automatically return to normal use. Table 1: Voltage Dips/Interruptions Test U2 (% Reduction) Td (Periods) Phase Angle N 100 0.5 0/90/180/270 3 100 1 0/90/180/270 3 30 25 0/90/180/270 3 100 250 0/90/180/270 3 Result A A A B RV1126 Test Mode: Note: M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working B indicates that the power supply of the EUT was interrupted during the test, and the EUT was restarted. After the test, it can automatically return to normal use. Table 1: Voltage Dips/Interruptions Test U2 (% Reduction) Td (Periods) Phase Angle N 100 0.5 0/90/180/270 3 100 1 0/90/180/270 3 30 25 0/90/180/270 3 100 250 0/90/180/270 3 Result A A A B Page 74 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) 13 - SURGES Test System Setup Ground Reference Plane Report No.: DG1221220-62768E-02 EUT Wooden Table 80cm 10cm Grounding Cable Test Level Ground Reference Plane Level 1 2 3 4 X Open Circuit Output Test Voltage ±10 0.5 kV 1 kV 2 kV 4 kV Special Performance Criterion: B Test Procedure 1) For line to line coupling mode, provide a 0.5 kV 1.2/50us voltage surge (at open-circuit condition). 2) At least 5 positive and 5 negative (polarity) tests with a maximum 1/min repetition rate are conducted during test. 3) Different phase angles are done individually. 4) Record the EUT operating situation during compliance test and decide the EUT immunity criterion for above each test. Page 75 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Test Data Please refer to following tables: RV1109 Test Mode: Note: M1: Operating & Wireless Linking M2: Operating Wired Linking&TF Card Working M3: Operating & USB flash disk Working Table 1:AC mains power input port Level Voltage Poll 1 0.5kV ± 2 1kV ± 3 2kV ± 4 4kV ± Path Line-Line Line-Line / / Table 2: RJ45 I/O Circuit and Lines Level Voltage Poll 1 0.5kV ± 2 1kV ± 3 2kV ± Path Line-Ground Line-Ground Line-Ground RV1126 Test Mode: Note: M1: Operating &Wireless Linking M2:Operating & TF Card Working M3:Operating &USB flash disk Working Table 1: AC mains power input port Level Voltage Poll 1 0.5kV ± 2 1kV ± 3 2kV ± 4 4kV ± Path Line-Line Line-Line / / Table 2: RJ45 I/O Circuit and Lines Level Voltage Poll 1 0.5kV ± 2 1kV ± 3 2kV ± Path Line-Ground / / Report No.: DG1221220-62768E-02 Pass Fail A / A / / / / / Pass Fail A / / / / / Pass Fail A / A / / / / / Pass Fail A / / / / / Page 76 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBITA - EUT PHOTOGRAPHS Report No.: DG1221220-62768E-02 Page 77 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Page 78 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Page 79 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Page 80 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Port Report No.: DG1221220-62768E-02 Port Page 81 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Uncover Report No.: DG1221220-62768E-02 Page 82 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Page 83 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Page 84 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Zigbee Antenna Report No.: DG1221220-62768E-02 BLE&WiFi Antenna Page 85 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Page 86 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 RV1126 Page 87 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Chip Page 88 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Chip Report No.: DG1221220-62768E-02 CPU BoardRV1126 Page 89 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Chip Page 90 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Chip Page 91 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Page 92 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Chip Report No.: DG1221220-62768E-02 Chip Page 93 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Note: The onboard antenna is not used. Chip Page 94 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) CPU Board (RV1109) Report No.: DG1221220-62768E-02 Page 95 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Chip Report No.: DG1221220-62768E-02 Chip Page 96 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Page 97 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Chip Report No.: DG1221220-62768E-02 Page 98 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG1221220-62768E-02 Page 99 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBITB - TEST SETUP PHOTOGRAPHS RE RE Below 1GHz front View Report No.: DG1221220-62768E-02 RE Below 1GHz rear View Page 100 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) RE Above 1GHz front View Report No.: DG1221220-62768E-02 RE Above 1GHz rear View Page 101 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) CE_AC CE front View Report No.: DG1221220-62768E-02 CE side View Page 102 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) CE_ISN CE front View Report No.: DG1221220-62768E-02 CE side View Page 103 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Flicker Test Setup Photo View M1 Report No.: DG1221220-62768E-02 Page 104 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) RS Test Setup Photo View Report No.: DG1221220-62768E-02 Page 105 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) ESD Test Setup Photo View Report No.: DG1221220-62768E-02 Page 106 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) EFT Test Setup Photo View Report No.: DG1221220-62768E-02 Signal Port Test Setup Photo Page 107 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Dips Test Setup Photo View Report No.: DG1221220-62768E-02 Page 108 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) Surge Test Setup Photo View Report No.: DG1221220-62768E-02 Signal Port Test Setup Photo Page 109 of 110 Bay Area Compliance Laboratories Corp. (Dongguan) CS Test Setup Photo View Report No.: DG1221220-62768E-02 Signal Port Test Setup Photo *****END OF REPORT***** Page 110 of 110Acrobat Distiller 11.0 (Windows); modified using iTextSharp 4.1.6 by 1T3XT