N9020A MXA X-Series Signal Analyzer

This configuration guide will help determine which performance options, measurement applicatioins, accessories and services to include with a new MXA or to add as upgrades to an existing MXA.

MXA, N9020A, X-Series, configuration, guide, signal, analyzer

PDF preview unavailable. Download the PDF instead.

5989-4943
CONFIGURATION GUIDE
MXA X-Series Signal Analyzer N9020A
This MXA configuration guide will help you determine which performance options, measurement applications, accessories, and services to include with your new MXA or to add as upgrades to an existing MXA.

Configure Your Keysight N9020A MXA Signal Analyzer
This step-by-step process will help you configure your new N9020A MXA X-Series signal analyzer. Tailor the performance to meet your requirements. For detailed specifications, refer to the specification guide (N9020-90113). For a summary of specifications, refer to the data sheet (5989-4942EN).
Included in base product
Standard options and accessories come with the PXA base model at no additional charge and do not need to be ordered. They include:
­­ Spectrum analyzer measurement application ­­ Dual-core, high-performance processor, 8 GB RAM, removable solid-state drive ­­ Frequency reference ­­ Mechanical attenuator ­­ 10 MHz/25 MHz analysis bandwidth ­­ Enhanced phase noise ­­ Microsoft Windows 10 operating system ­­ Real-time link ­­ Benchtop configuration ­­ Mouse ­­ User guide ­­ Front-panel protective cover ­­ Power cord

Step 1. Select maximum frequency range (required option)

Description

Option number

Frequency range, 10 Hz to 3.6 GHz

N9020A-503

Frequency range, 10 Hz to 8.4 GHz

N9020A-508

Frequency range, 10 Hz to 13.6 GHz

N9020A-513

Frequency range, 10 Hz to 26.5 GHz

N9020A-526

Step 2. Add a preamplifier Description

Option number

Preamplifier, 100 kHz to 3.6 GHz
Preamplifier, 100 kHz to 8.4 GHz
Preamplifier, 100 kHz to 13.6 GHz Preamplifier, 100 kHz to 26.5 GHz
Step 3. Choose frequency reference Description Frequency reference Precision frequency reference

N9020A-P03
N9020A-P08
N9020A-P13 N9020A-P26
Option number Standard N9020A-PFR

Step 4. Choose an attenuator Description Mechanical attenuator Electronic attenuator up to 3.6 GHz

Option number Standard N9020A-EA3

Additional information
Additional information Preamplifiers improve the noise floor for low-level signal detection; +20 dB: 100 kHz to 3.6 GHz, +35 dB: 3.6 GHz to 26.5 GHz Compatible with frequency range options: N9020A-503, N9020A-508, N9020A-513, and N9020A-526 Compatible with frequency range options: N9020A-508, N9020A-513, and N9020A-526 Compatible with frequency range options: N9020A-513 and N9020A-526 Compatible with frequency range option: N9020A-526
Additional information Aging rate: ± 1 x 10­6/year
­­ Reduces frequency drift for more accurate measurements ­­ Aging rate: ± 1 x 10­7/year
Additional information 2 dB steps, 0 to 70 dB In addition to the mechanical attenuator; 1 dB steps, 0 to 24 dB

Find us at www.keysight.com

Page 2

Step 5. Choose analysis bandwidth Description 10 MHz/25 MHz analysis bandwidth 40 MHz analysis bandwidth
85 MHz analysis bandwidth
125 MHz analysis bandwidth
160 MHz analysis bandwidth
Microwave preselector bypass

Option number Additional information

Standard

Useful for most cellular communications, wireless connectivity, and audio/video broadcasting

measurement applications; licensed as N9020A-B25

N9020A-B40 Extends the analysis bandwidth to 40 MHz

(Option MPB required for measurements at frequency > 3.6 GHz); included in B85, B1A, or

B1X; also enables fast sweep capability licensed as N9020A-FS1 and N9020A-FS2; if Option

BAA is installed, provides 40 MHz per channel baseband bandwidth

N9020A-B85 Extends the analysis bandwidth to 85 MHz

(Option MPB required for measurements > 3.6 GHz); also enables fast sweep capability

licensed as N9020A-FS1 and N9020A-FS2; not compatible with Option BBA

N9020A-B1A Extends the analysis bandwidth to 125 MHz

(Option MPB required for measurements > 3.6 GHz); also enables fast sweep capability

licensed as N9020A-FS1 and N9020A-FS2; not compatible with Option BBA

N9020A-B1X Extends the analysis bandwidth to 160 MHz

(Option MPB required for measurements > 3.6 GHz); also enables fast sweep capability

licensed as N9020A-FS1 and N9020A-FS2; not compatible with Option BBA

N9020A-MPB Required for wide analysis bandwidth measurements with Option B40, B85, B1A, or B1X

at frequency > 3.6 GHz; also enables fast sweep capability licensed as N9020A-FS1 and

N9020A-FS2

Step 6. Choose performance options Description Enhanced phase noise Digital processor with 2 GB capture memory I/Q baseband inputs, analog
External mixing
Noise floor extension

Option number Standard 1 N9020A-DP2
N9020A-BBA
N9020A-EXM
N9020A-NFE

Additional information Licensed as N9020A-EP2 Comes standard with Option B40, B85, B1A, or B1X; also enables fast sweep capability licensed as N9020A-FS1 and N9020A-FS2 Single-ended/differential, 50 /1 M impedance; not compatible with Option B85, B1A, or B1X Connects with Keysight and third party mixers to extend frequency coverage up to 1.1 THz; single port 2 for LO out and IF in (SMA female) Improves analyzer's DANL performance (instrument alignment based processes); licensed as N9020A-NF2

Find us at www.keysight.com

Page 3

Step 7. Add real-time spectrum analysis Note: Keysight offers 4 license types for the measurement applications and instrument features, in 2 license terms: Perpetual or Time-based.

License types: -- Node-locked: Allows you to use the license on one instrument/computer at a time -- Transportable: Allows you to use the license on one instrument/computer at a time. This license may be transferred to another instrument/
computer using Keysight's online tool -- Floating: Allows you to access the license on the networked instruments/computers from a server, one at a time. For concurrent access, multiple
licenses may be purchased -- USB Portable: Allows you to access the license from one instrument/computer to another by end-user only with certified USB dongle, purchased
separately

License terms: -- Perpetual: License can be used in perpetuity. For perpetual license holders, a separate support contract is required to access Keysight technical
support and software updates -- Time-based: License is time limited to a defined period, such as 12-months. A valid support contract is included in the pricing for time-based
licenses.

For detailed information, we strongly recommend you visit the X-Series measurement application collection page: www.keysight.com/find/xseriesapps

Description Real-time analysis up to 160 MHz BW, basic detection
Real-time analysis up to 160 MHz BW, optimum detection
Real-time spectrum recorder and analyzer application

Model number N9020RT1A
N9020RT2A
N9020A-RTR

Additional information Includes frequency mask trigger (FMT) and time qualified trigger (TQT); minimum 17.3 s signal duration for 100% probability of intercept (POI); requires Option B85, B1A, or B1X, which determines maximum real-time bandwidth; also supports Option EXM Includes frequency mask trigger (FMT) and time qualified trigger (TQT); minimum 3.57 s signal duration for 100% probability of intercept (POI); requires Option B1X, B1A, or B85, which determines maximum real-time bandwidth; also supports Option EXM Enables recording, analyzing and playback of spectrum density data over time for detecting and analyzing signal anomalies; requires Option RT1 (N9020RT1A) or RT2 (N9020RT2A)

1. All instruments with serial number prefix  MY/SG/US5233 are installed with the N9020A-EP2 standard for the enhanced phase noise performance. The N9020A-EP2 is not upgradable.
2. When used with the Keysight 11970 Series external mixers, an external diplexer is required. Recommended diplexer can be purchased from Keysight as N9029AE13, or from OML Inc. as DPL313B.

Find us at www.keysight.com

Page 4

Step 8. Add optional features Description Fast power Time domain scan

Model number N90EMFP2A N90EMTDSA

Resolution bandwidth extended Enhanced display package Basic EMI precompliance
External source control

N90EMRBEA N90EMEDPA N90EMEMCA
N90EMESCA

Step 9. Choose operating system Description Windows 10 operating system
Step 10. Add security features Description Additional removable solid-state drive
Exclude launch program Prohibit saving results

Option number Standard
Option number N9020A-SS1
N9020A-SF1 N9020A-SF2

Step 11. Add rear panel output utilities Description Second IF output

Option number N9020A-CR3

Arbitrary IF output Y-axis screen video output Real-time link

N9020A-CRP N9020A-YAS Standard

Additional information Accelerates the power measurements such as ACPR; requires Option B40 Improves scan speed for EMC pre-compliance tests; requires N6141A EMC precompliance measurement application and Option DP2, or B40 (or wider bandwidth option) Extends the maximum RBW in Zero Span; requires option B85, B1A, or B1X Includes spectrogram, trace zoom, and zone span Perform basic EMI precompliance measurements with CISPR 16-1-1 detectors and bandwidths; tune and listen, and measure at marker are also available External source control for Keysight EXG, MXG, and PSG signal generators; supports external mixing; includes 3 BNC cables and 1 cross-over LAN cable
Additional information Licensed as N9020A-W10
Additional information Provides a fully-imaged, removable solid-state drive in addition to the one installed in the instrument, with Windows 10 operating system Prevents the launching of Windows programs from the instrument application Prevents the saving/recall of measurement results or user configurations to/from instrument's data storage
Additional information Wideband IF out; center frequency depends on IF path; output on Aux IF connector at rear panel IF out 10 to 75 MHz (in 500 kHz steps); output on Aux IF connector at rear panel Screen video (0-1 volt open circuit) on rear panel analog out The LVDS connector allows MXA to connect to X-COM data recorder for data streaming (up to 40 MHz BW), and to the N5106A PXB baseband generator and channel emulator; requires Option B40 or DP2; licensed as N9020A-RTL

Find us at www.keysight.com

Page 5

Step 12. Choose measurement application or software and license type Note: Keysight offers 4 license types for the measurement applications and instrument features, in 2 license terms: Perpetual or Time-based.
License types: -- Node-locked: Allows you to use the license on one instrument/computer at a time -- Transportable: Allows you to use the license on one instrument/computer at a time. This license may be transferred to another instrument/
computer using Keysight's online tool -- Floating: Allows you to access the license on the networked instruments/computers from a server, one at a time. For concurrent access, multiple
licenses may be purchased -- USB Portable: Allows you to access the license from one instrument/computer to another by end-user only with certified USB dongle, purchased
separately
License terms: -- Perpetual: License can be used in perpetuity. For perpetual license holders, a separate support contract is required to access Keysight technical
support and software updates -- Time-based: License is time limited to a defined period, such as 12-months. A valid support contract is included in the pricing for time-based
licenses.
For detailed information, we strongly recommend you visit the X-Series measurement application collection page: www.keysight.com/find/xseriesapps

Description
General purpose Spectrum analyzer

Model number Standard

Analog demodulation N9063EM0D

Phase noise Noise figure

N9068EM0D
N9069EM0D (requires preamplifier)

VXA Vector Signal Analysis

N9064EM0D

EMI Remote language compatibility SCPI command language compatibility MATLAB software 89600 vector signal analysis (VSA) software

N6141EM0D N9061EM0D
N9062EM0D
N6171A 89601B (transportable license is standard)

Additional information
Traditional spectrum analysis plus many new and enhanced functions; power measurements based on industry specifications; licensed as N9060EM1D Adds one-button measurement for AM/FM/PM demodulation with metrics, tune and listen, and AF spectrum; supports audio output (output voltage proportional to frequency deviation). FM Stereo and RDS are included Adds one-button measurements for analyzing phase noise in frequency domain (log plot) and time domain (spot frequency), supports external mixing Adds one-button measurements for noise figure, gain, and related metrics; requires preamplifier to meet specifications; works with Keysight U1831C USB noise source, N400xA Series smart noise sources and 346 Series noise sources; supports U7227 USB external preamplifiers Includes the advanced NF measurement features including external LO control over GPIB/LAN/USB, multi-stage converter tests with system LO, and manual mode to simulate the legacy NF meter Vector signal analysis; high-resolution, FFT-based spectrum and time-domain measurements, time gating, AM/FM/PM demodulation, statistical measurements; flexible digital modulation analysis; general purpose digital modulation for 2-16FSK, 2-8PSK, and 16-1024QAM, as well as more than 15 additional formats Performs pre-compliance conducted and radiated emission measurements Adds capability to emulate HP/Agilent 8566/68 and 856xE/EC spectrum analyzers
Adds capability to emulate the R&S FSP/FSU/FSE/FSL/FSV spectrum analyzers or ESU EMI receiver
Industry-leading measurement software for evaluating and troubleshooting signals in R&D; PC-based software supporting more than 30 measurement platforms, plus more than 75 signal standards and modulation types including MIMO analysis; www.keysight.com/find/89600_VSA

Find us at www.keysight.com

Page 6

Step 12. Choose measurement application or software and license type

Description

Model number

Additional information

Cellular communications

GSM/EDGE/Evo

N9071EM0D

N9071EMXD

cdma2000 W-CDMA/HSPA+

N9072EM0D N9073EM0D
N9073EMXD

1xEV-DO TD-SCDMA/HSPA LTE/LTE-Advanced FDD LTE/LTE-Advanced TDD Multi-Standard Radio (MSR) Wireless connectivity Mobile WiMAXTM WLAN 802.11 a/b/g/j/p/n/af/ah WLAN 802.11ac/ax Bluetooth® Digital video Digital Cable TV DVB-T/H/T2/T2-Lite ISDB-T/Tmm DTMB(CTTB)

N9076EM0D N9079EM0D N9080EM0D N9082EM0D N9083EM0D
N9075EM0D N9077EM0D
N9077EM1D N9081EM0D
N6152EM0D N6153EM0D N6155EM0D N6156EM0D

Standard-based, one-button GSM/EDGE/EDGE Evolution measurements Adds single acquisition combined measurement, a SCPI-commandbased measurement optimized for high-volume, high-throughput manufacturing; requires N9071EM0D; not compatible with Options DP2, B40, B85, B1A, B1X, or MPB Standard-based, one-button cdma2000 and cdmaOne measurements Standard-based, one-button W-CDMA, HSPA and HSPA+ measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) Adds single acquisition combined measurement, a SCPI-commandbased measurement optimized for high-volume, high-throughput manufacturing; requires N9073EM0D; not compatible with Options DP2, B40, B85, B1A, B1X, or MPB Standard-based, one-button 1xEV-DO Rel 0, Rev A, and Rev B measurements Standard-based, one-button TD-SCDMA/HSPA/8PSK measurements Standard-based, one-button LTE/LTE-Advanced FDD measurements Standard-based, one-button LTE/LTE-Advanced TDD measurements Standard-based, one-button MSR measurements on any combination of LTE-FDD, LTE-TDD, W-CDMA/HSPA/HSPA+, GSM/EDGE/EDGE Evo, cdma2000, 1xEV-DO and TD-SCDMA signals
Standard-based, one-button Mobile WiMAX measurements Standard-based, one-button 802.11a/b/g/j/p/n/af/ah measurement
Standard-based, one-button 802.11ac/ax measurement Standard-based, one-button Bluetooth (BR/EDR, Low Energy 4.0/4.2 and Bluetooth 5) measurements
Standard-based, one-button DVB-C (J.83 Annex A/C) and J.83 Annex B measurements Standard-based, one-button DVB-T/H, DVB-T2/T2-Lite measurements Standard-based, one-button ISDB-T, ISDB-TB, ISDB-TSB, and ISDB-Tmm measurements Standard-based, one-button DTMB (CTTB) measurements

Step 13. Choose physical instrument configuration

Description

Option number

Additional information

Bench top configuration Standard

Provides two side carrying straps, four rear feet, and four bottom feet with a tilt stand; a front panel

protective cover is included

Portable configuration N9020A-PRC

Provides a convenient, pivoting carrying handle as well as rubber protective corners and end guards;

this configuration is intended for applications requiring more rugged packaging, such as in the field

MXA bench top configuration Find us at www.keysight.com

Portable configuration includes pivoting carrying handle and protective corner rubber guards (front protective cover comes standard) ­ N9020A-PRC
Page 7

Step 14. Choose accessories Description Mouse, USB interface User guide
Front-panel protective cover Power cord Rack mount Front handles Rack mount with handles Rack slide Accessory pouch USB DVD-ROM/CD-R/RW drive Hard transit case US 65-key USB keyboard Keyboard, USB interface
Minimum loss pad, 50 to 75  (type-N to BNC)
V-band waveguide harmonic mixer, 50 to 75 GHz Extended V-band waveguide harmonic mixer, 50 to 80 GHz E-band waveguide harmonic mixer, 60 to 90 GHz W-band waveguide harmonic mixer, 75 to 110 GHz E-band waveguide harmonic mixer, 60 to 90 GHz Extended E-band waveguide harmonic mixer, 55 to 90 GHz V-band waveguide harmonic mixer, 55 to 75 GHz W-band waveguide harmonic mixer, 75 to 110 GHz 26 to 40 GHz waveguide harmonic mixer 33 to 50 GHz waveguide harmonic mixer 40 to 60 GHz waveguide harmonic mixer 50 to 75 GHz waveguide harmonic mixer 75 to 110 GHz waveguide harmonic mixer LO/IF diplexer 90 to 140 GHz OML harmonic mixer 110 to 170 GHz OML harmonic mixer 140 to 220 GHz OML harmonic mixer 220 to 325 GHz OML harmonic mixer 50 to 75 GHz frequency extension module 60 to 90 GHz frequency extension module 75 to 110 GHz frequency extension module 90 to 140 GHz frequency extension module 110 to 170 GHz frequency extension module 140 to 220 GHz frequency extension module 220 to 330 GHz frequency extension module 325 to 500 GHz frequency extension module 550 to 750 GHz frequency extension module 750 to 1100 GHz frequency extension module Power supply for VDI module USB external preamplifier, 10 MHz to 4 GHz USB external preamplifier, 0.1 to 26.5 GHz USB external preamplifier, 2 to 50 GHz

Option number Standard Standard
Standard Standard N9020A-1CM N9020A-1CN N9020A-1CP N9020A-1CR N9020A-BAG N9020A-DVR N9020A-HTC N9020A-KB2 N9020A-KYB
N9020A-MLP
M1970V-001 M1970V-002
M1970E M1970W M1971E-001 M1971E-003
M1971V M1971W 11970A 11970Q 11970U 11970V 11970W N9029AE13 N9029AE08 N9029AE06 N9029AE05 N9029AE03 N9029AV15 N9029AV12 N9029AV10 N9029AV08 N9029AV06 N9029AV05 N9029AV03 N9029AV02 N9029AV1B N9029AV01 N5262VDI-175 U7227A U7227C U7227F

Additional information Enhances the usability of the Windows operating system
­­ US ­ English localization ­­ All user documentation is included in the MXA's embedded, context-sensitive
help system and on a DVD that is shipped with the instrument ­­ User documentation can be downloaded from:
www.keysight.com/find/mxa_manuals
Dependent upon the region of use Adds rack mount flanges to the MXA Adds front handles to the MXA Adds rack mount flanges and handles to the MXA Adds a non-tilting rack slide to the MXA Easily store and carry the N9020A-KB2 keyboard and USB mouse Enhances the usability of the Windows operating system Ultra-durable, wheeled carrying case offers maximum protection and portability Compact design fits in N9020A-BAG accessory pouch for convenient storage Enhances the usability of the Windows operating system (Note: Does not fit N9020A-BAG accessory pouch)
­­ 50  type-N male to 75  BNC female adapter ­­ Frequency range: 9 MHz to 2 GHz ­­ Input/output return loss: 20 and 11 dB ­­ Insertion loss: 5.7 dB Requires Option EXM; USB mixer with smart features Requires Option EXM; USB mixer with smart features
Requires Option EXM; USB mixer with smart features Requires Option EXM; USB mixer with smart features Requires Option EXM; USB mixer with smart features and 3 signal paths Requires Option EXM; USB mixer with smart features and 3 signal paths
Requires Option EXM; USB mixer with smart features and 3 signal paths Requires Option EXM; USB mixer with smart features and 3 signal paths Requires Option EXM and N9029AE13 diplexer Requires Option EXM and N9029AE13 diplexer Requires Option EXM and N9029AE13 diplexer Requires Option EXM and N9029AE13 diplexer Requires Option EXM and N9029AE13 diplexer Ordering convenience; required for 11970 Series external mixers Ordering convenience; requires Option EXM Ordering convenience; requires Option EXM Ordering convenience; requires Option EXM Ordering convenience; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM VDI signal analyzer frequency extension module; requires Option EXM Required for the N9029AVxx VDI module Requires firmware A.14.00 or higher Requires firmware A.14.00 or higher Requires firmware A.14.00 or higher

For more information on accessories go to: www.keysight.com/find/accessories

Find us at www.keysight.com

Page 8

Step 15. Choose localized Getting Started guides

Description

Option number

Getting started guide MXA Korean

N9020A-AB1

Getting started guide MXA Chinese

N9020A-AB2

Getting started guide MXA German

N9020A-ABD

Getting started guide MXA French

N9020A-ABF

Getting started guide MXA Japanese

N9020A-ABJ

Getting started guide MXA Russian

N9020A-AKT

Step 16. Add calibration, technical training, support, and upgrade services

Description

Option number

Additional information

Commercial calibration certificate with test data N9020A-UK6

Calibration certificate only available at time of instrument purchase; only

provides measurement results

Keysight Calibration + Uncertainties +

N9020A-AMG

Provides ISO 17025A accredited calibration from factory

Guardbanding (accredited cal)

ANSI Z540-1-1994 Calibration

N9020A-A6J

Provides ANSI Z540 compliant calibration from factory

Calibration Assurance Plan,

R-50C-011-3

Keysight tests your instrument against its original specifications and

Return-to-Keysight, 3 years

automatically makes adjustments if outside of specified parameters; pre-

and post-adjustment measurement data reports also provided

Service: remote scheduled productivity

PS-S10-100

Hourly phone-in technical support service designed to help you understand

assistance

and operate your equipment through convenient phone and Web access

Service: 1-day start-up assistance

PS-S20-01

Training on how to operate your instrument effectively (recommended)

Service: productivity assistance

PS-S20-100

Daily instrument and application consulting using your equipment and device

under test

Service: custom engineering service

PS-X10-100

Application-specific technical assistance

Other calibration options may be available; for more information on calibration go to: www.keysight.com/find/calibration For more information on training and application support services go to: www.keysight.com/find/training

Find us at www.keysight.com

Page 9

Instrument Upgrades
Fast license-key upgrades for performance options that do not require additional hardware:
1. Place an order for the upgrade with Keysight and request to receive the option upgrade entitlement certificate and a one-time software upgrade license through email
2. Redeem the certificate through the Web by following the instructions on the certificate
3. Install the license file and latest software in the MXA 4. Begin using the new capability 1, 2
Installation and testing information is available at: www.keysight.com/find/mxa_upgrades

You can upgrade!
Options can be added after your initial purchase.
All of our X-Series application options are license-key upgradeable.

Upgrades for analysis bandwidth depend on the vintage of the instrument and the options already installed. More than one option may be required to achieve desired wider analysis bandwidth. Use our web-based calculator to find the upgrade options you may need: www.keysight.com/find/BW-selector

Description
Increase frequency from 3.6 to 8.4 GHz Increase frequency from 3.6 to 13.6 GHz Increase frequency from 3.6 to 26.5 GHz Increase frequency from 8.4 to 13.6 GHz Increase frequency from 8.4 to 26.5 GHz Increase frequency from 13.6 to 26.5 GHz Increase analysis bandwidth from 10 MHz to 25 MHz Increase analysis bandwidth from 10 to 40 MHz Increase analysis bandwidth from 25 to 40 MHz Increase analysis bandwidth to 40 MHz. Option 508, 513, and 526 only
Increase analysis bandwidth to 40 MHz, Option 503 only
Increase analysis bandwidth from 10/25 MHz to 85 MHz; Option 503 only Increase analysis bandwidth from 10/25 MHz to 85 MHz; Option 508, 513, and 526 only

Upgrade number
N9020AK-F01 N9020AK-F02 N9020AK-F03 N9020AK-F06 N9020AK-F07 N9020AK-F10 N9020AK-B25 3
N9020AK-B40
N9020AK-BU1
N9020AK-HL4
N9020AK-HLA
N9020AK-HL8
N9020AK-HL9
N9020AK-HLD
N9020AK-HLE

Requirements (MXA must already include the following) 503 503 503 508 508 513 None
DP2 or MPB
B25 and DP2 or MPB
508, 513, or 526 Serial prefix < US/SG/MY5233 508, 513, or 526 Serial prefix  US/SG/MY5233 503 Serial prefix < US/SG/MY5233 503 Serial prefix  US/SG/MY5233 503 Serial prefix < US/SG/MY5233 508, 513, 526 Serial prefix < US/SG/MY5233

Additional information
Also enables 25 MHz per channel baseband bandwidth if Option BBA is installed Also enables 40 MHz per channel baseband bandwidth if Option BBA is installed Also enables 40 MHz per channel baseband bandwidth if Option BBA is installed Includes hardware and license key; also adds microwave preselector bypass and enables 40 MHz per channel baseband bandwidth if Option BBA is installed; not compatible with Option 503 Includes hardware and license key; also enables 40 MHz per channel baseband bandwidth if Option BBA is installed; only compatible with Option 503
Includes hardware and license key; only compatible with Option 503; not compatible with Option BBA Includes hardware and license key; also add microwave preselector bypass; only compatible with Option 508, 513, 526; not compatible with Option BBA

1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was verified to be within its warranted specifications. Within two years of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or verification testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its two years, or if the analyzer is more than two years old, additional adjustment and performance verification tests are required to ensure that some newly installed options are functioning properly. However, the completion of these tests does not guarantee that the analyzer meets all warranted specifications.
3. This upgrade option is for instrument(s) ordered before May 1, 2011.

Find us at www.keysight.com

Page 10

Description
Increase analysis bandwidth from 40 MHz to 85 MHz
Increase analysis bandwidth from 85 MHz to 125 MHz Increase analysis bandwidth from 85 MHz to 160 MHz Increase analysis bandwidth from 125 MHz to 160 MHz Real-time analysis up to 160 MHz BW, basic detection

Upgrade number N9020AK-HLB N9020AK-HLC N9020AK-BU4

Requirements (MXA must already include the following) B40 Serial prefix < US/SG/ MY5233 B40 Serial prefix  US/SG/ MY5233 B85

N9020AK-BU5 B85

N9020AK-BU6 B1A

N9020AK-RT1

B85, B1A, or B1X (Analysis BW option determines maximum real-time BW)

Real-time analysis up to 160 MHz BW, N9020AK-RT2 optimum detection

B1X, B1A, or B85 (Analysis BW option determines maximum real-time BW)

Real-time spectrum recorder and analyzer application

N9020AK-RTR RT1 or RT2

Upgrade to the precision frequency reference Add an electronic attenuator, 3.6 GHz Add preamplifier, 3.6 GHz Add preamplifier, 8.4 GHz Add preamplifier, 13.6 GHz Add preamplifier, 26.5 GHz Add analog baseband IQ inputs Add basic precompliance EMI features

N9020AK-PFR
N9020AK-EA3 N9020AK-P03 N9020AK-P08 N9020AK-P13 N9020AK-P26 N9020AK-BBA N9020AK-EMC

None
None None None None None None None

Add external source control

N9020AK-ESC None

Add external mixing Add fast power

N9020AK-EXM
N9020AK-HL6 N9020AK-FP2

Serial prefix  US/SG/ MY5233 but < US/SG/ MY5318 Serial prefix  US/SG/ MY5318 B40, or B85, B1A, B1X

Add noise floor extension Add security features, exclude launch program
Add security features, prohibit saving results

N9020AK-NFE N9020AK-SF1
N9020AK-SF2

None None
None

Additional information
Includes hardware and license key; not compatible with Option BBA
License key only
License key only
License key only
Includes frequency mask trigger (FMT) and time qualified trigger (TQT); minimum 17.3 µs signal duration for 100% POI; supports external mixing Option EXM; license key upgrade. Combination of Win 7/PC4 or Win 7/PC6 required for optimal display performance. Also orderable at N9020RT1A (requires F/W revision A.21.04 onward) Includes frequency mask trigger (FMT) and time qualified trigger (TQT); minimum 3.57 µs signal duration for 100% POI; supports external mixing Option EXM; license key upgrade; combination of Win 7/PC4 or Win 7/PC6 required for optimal display performance. Also orderable at N9020RT2A (requires F/W revision A.21.04 onward) Enables recording, analyzing, and playback of spectrum density data over time for detecting and analyzing signal anomalies
Not compatible with Option 503 Not compatible with Options 503, 508 Not compatible with Options 503, 508, 513 Not compatible with Options B85, B1A, B1X Also orderable at N90EMEMCA (requires F/W revision A.21.04 onward) Adds feature to control the Keysight EXG, MXG, and PSG signal generators; includes 3 BNC cables and 1 cross-over LAN cable. Also orderable at N90EMESCA (requires F/W revision A.21.04 onward) Includes hardware and license key
Includes hardware and license key
For fast power measurements such as ACPR. Also orderable at N90EMFP2A (requires F/W revision A.21.04 onward) Instrument alignment based; licensed as N9020A-NF2 Prevents the launching of Windows programs from the instrument application Prevents the saving/recall of measurement results or user configurations to/from instrument's data storage

Find us at www.keysight.com

Page 11

Description

Upgrade number Requirements (MXA must already

Additional information

include the following)

Upgrade operating system to Windows 10

From old processors

N9094AK-W10 1

N9094AK-PC6 1

PC1, PC2 or PC4

Upgrade to a quad-core 64-bit performance processor, 16 GB RAM, with removable solid-state drive and Windows 10

From the latest processors

N9094AK-W10 1 PC6 N9094AK-SSD 1

operating system Provides a removable solid-state drive with Windows 10 operating system

Upgrade to dual core 64-bit performance processor, 16 GB RAM, removable solid-state drive

With Windows 10 operating system

N9094AK-W10 1 PC1, PC2 or PC4

Upgrade to a quad-core 64-bit performance processor, 16

N9094AK-PC6 1

GB RAM, with removable solid-state drive and Windows 10

operating system

Add additional removable solid-state drive

With Windows 10 operating system

N9094AK-W10 1 PC6

N9094AK-SSD 1

For Windows 10 operating system provides additional removable solid-state drive

Upgrade to multi-touch user interface

From PC6 processor

N9020AK-MTU PC6

Allows signal analyzer to run multi-touch applications2

Available for N9020A MXA signal analyzers with S/N prefix  MY/SG/US5233

From other processor

N9020AK-MTP None

Allows signal analyzer to run multi-touch applications and

upgrades to a quad-core 64-bit performance processor, 16 GB RAM2. Available for N9020A MXA signal analyzers with S/N prefix  MY/SG/Us5233

Add second IF output

N9020AK-CR3 B40, B85, B1A, B1X, DP2,

MPB, or CRP

Add arbitrary IF output

N9020AK-CRP

Front end controller with Press System, Show, Hardware to determine hardware ID hardware ID of 41 or 75

Add second IF output and arbitrary

N9020AK-HL3 None

Includes hardware and license key

IF output

Add time domain scan capability

N9020AK-TDS

N6141A and DP2, or B40 For EMC pre-compliance tests only. Also orderable at

(or wider BW)

N90EMTDSA (requires F/W revision A.21.04 onward)

Add resolution bandwidth extended N9020AK-RBE B85, B1A, or B1X

Also orderable at N90EMRBEA (requires F/W revision A.21.04

onward)

Add Y-axis screen video output

N9020AK-YAS None

Add enhanced display package

N9020AK-EDP None

Also orderable at N90EMEDPA (requires F/W revision A.21.04 onward)

USB DVD-ROM/CD-R/RW drive

N9020AK-DVR None

Keyboard, USB interface

N9020AK-KYB None

Enhances the usability of the Windows operation system (Note: Does not fit N9020A-BAG accessory pouch)

US 65-Key USB keyboard

N9020AK-KB2 None

Compact design fits in N9020A-BAG accessory pouch for

convenient storage

Accessory pouch

N9020AK-BAG None

Easily store and carry the N9020AK-KB2 keyboard and USB mouse in this attachable pouch

Hard transit case

N9020AK-HTC None

Rack mount and handle kit

N9020AK-1CP None

Not compatible with Options PRC, 1CM, 1CN

Front handle kit

N9020AK-1CN None

Not compatible with Options PRC, 1CM, 1CP

Rack mount kit

N9020AK-1CM None

Not compatible with Options PRC, 1CP, 1CN

Rack slide kit

N9020AK-1CR None

Not compatible with Option PRC

Portable configuration

N9020AK-PRC None

Not compatible with Options 1CM, 1CP, 1CN, 1CR

Minimum loss pad, 50 to 75  (type-N to BNC)

N9020AK-MLP None

Front panel protective cover, additional N9020AK-CVR None

1. Must be ordered under N9020AK. 2. Not all applications supported by the N9020A with standard user interface (UI) are supported with the multi-touch UI. Consult your nearest Keysight sales
representative for detailed information.

Find us at www.keysight.com

Page 12

Description
System memory upgrade (2 GB)
Getting started guide MXA Korean Getting started guide MXA Chinese Getting started guide MXA German Getting started guide MXA French Getting started guide MXA Japanese Getting started guide MXA Russian

Upgrade number N9020AK-MS1

Requirements (MXA must already include the following) None

N9020AK-AB1 N9020AK-AB2 N9020AK-ABD N9020AK-ABF N9020AK-ABJ N9020AK-AKT

None None None None None None

Additional information
Increases system memory; does not increase capture memory and is not required for instruments with serial number prefixes equal to or greater than MY4738, SG4738, US4736

Note: It is recommended to order measurement applications with the model numbers listed at Step 12. Alternatively, you can use the ordering numbers in this table to add the measurement applications. The last two letters of the ordering numbers indicate the license type--FP stands for fixed perpetual, TP for transportable perpetual; it is recommended that you configure each application with the same license type; visit www.keysight.com/find/X-Series_transportable for more information about transportable licenses

Description

Fixed license Transportable Additional information

license

Cellular communications

LTE/LTE-Advanced N9080B-1FP N9080B-1TP Standard-based, one-button LTE-FDD measurements; requires W7X or W10

FDD

N9080B-2FP N9080B-2TP Standard-based, one-button LTE-Advanced FDD measurements; requires W7X or W10, and

N9080B-1FP/1TP

LTE/LTE-Advanced N9082B-1FP N9082B-1TP Standard-based, one-button LTE-TDD measurements; requires W7X or W10

TDD

N9082B-2FP N9082B-2TP Standard-based, one-button LTE-Advanced TDD measurements; requires W7X or W10, and

N9082B-1FP/1TP

Multi-standard

N9083A-1FP N9083A-1TP Standard-based, one-button MSR measurements on any combination of LTE-FDD, W-CDMA/

radio (MSR)

HSPA/HSPA+, GSM/EDGE/EDGE Evo, cdma2000 and 1xEV-DO signals

W-CDMA/HSPA+ N9073A-1FP N9073A-1TP Standard-based, one-button W-CDMA measurements; supports analog baseband analysis

with Option BBA (BBIQ inputs)

N9073A-2FP N9073A-2TP Adds HSPA measurements; requires 1FP/1TP

N9073A-3FP N9073A-3TP Adds HSPA+ measurements; requires 1FP/1TP, 2FP/2TP

N9073A-XFP N9073A-XTP Adds single acquisition combined measurement, a SCPI-

command-based measurement optimized for high-volume, high-throughput manufacturing;

requires 1FP/1TP; not compatible with Options DP2, B40, B85, B1A, B1X, or MPB

GSM/EDGE/EVO N9071A-2FP N9071A-2TP Standard-based, one-button GSM/EDGE measurements; supports analog baseband analysis

with Option BBA (BBIQ inputs)

N9071A-3FP N9071A-3TP Adds EDGE Evolution and VAMOS measurements; requires 2FP/2TP

N9071A-XFP N9071A-XTP Adds single acquisition combined measurement, a SCPI-command-based measurement

optimized for high-volume, high-throughput manufacturing; requires 2FP/2TP; not compatible

with Options DP2, B40, B85, B1A, B1X, or MPB

TD-SCDMA/HSPA N9079A-1FP N9079A-1TP Standard-based, one-button TD-SCDMA measurements; supports analog baseband analysis

with Option BBA (BBIQ inputs)

N9079A-2FP N9079A-2TP Adds HSPA/8PSK measurements, requires 1FP/1TP

1xEV-DO

N9076A-1FP N9076A-1TP Standard-based, one-button 1xEV-DO Rel 0, Rev A, and Rev B

measurements; supports analog baseband analysis with Option BBA (BBIQ inputs)

cdma2000®/

N9072A-2FP N9072A-2TP Standard-based, one-button cdma2000 and cdmaOne measurements; supports analog

cdmaOne

baseband analysis with Option BBA (BBIQ inputs)

Find us at www.keysight.com

Page 13

Description

Fixed license

Wireless connectivity Mobile WiMAXTM N9075A-2FP

Transportable license
N9075A-2TP

Fixed WiMAX

N9074A-XFP N9074A-XTP

WLAN 802.11a/b/g/n/ac

N9077A-2FP N9077A-3FP

N9077A-2TP N9077A-3TP

N9077A-4FP N9077A-4TP

Bluetooth®
Digital video CMMB

N9077A-6FP N9077A-7FP N9077A-8FP N9077A-MFP N9081A-2FP N9081A-3FP

N9077A-6TP N9077A-7FP N9077A-8TP N9077A-MTP N9081A-2TP N9081A-3TP

N6158A-2FP N6158A-2TP

Digital cable TV

N6152A-2FP N6152A-2TP

N6152A-3FP N6152A-3TP

DTMB (CTTB)

N6156A-2FP N6156A-2TP

DVB-T/H/T2

N6153A-2FP N6153A-2TP

ISDB-T/Tmm

N6153A-3FP N6155A-2FP

N6153A-3TP N6155A-2TP

General purpose Analog demodulation
Phase noise

N6155A-3FP N6155A-3TP

N9063A-2FP N9063A-2TP

N9063A-3FP N9068A-2FP

N9063A-3TP N9068A-2TP

Noise figure

N9069A-1FP (requires preamplifier to meet specifications)
N9069A-2FP

N9069A-1TP (requires preamplifier to meet specifications)
N9069A-2TP

VXA vector signal N9064A-1FP N9064A-1TP analysis

N9064A-2FP N9064A-2TP

EMC

N6141A-2FP N6141A-2TP

Additional information
Standard-based, one-button Mobile WiMAX measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) Single acquisition combined measurement, a SCPI-command-based measurement optimized for high-volume, high-throughput manufacturing; not compatible with Options DP2, B40, or MPB Standard-based, one-button 802.11a/b/g measurement Adds 802.11n; requires 2FP/2TP; requires wide analysis bandwidth option, see Step 5 to choose the right bandwidth Adds 802.11ac; requires 2FP/2TP, 3FP/3TP; requires wide analysis bandwidth option, see Step 5 to choose the right bandwidth Standard-based, one button 802.11ah measurement; Firmware above A.16.05 Standard-based, one button 802.11af measurement; Firmware above A.18.01 Standard-based, one button 802.11ax measurement; Firmware above A.19..05 Add 802.11ax OFDMA measurement (requires 8FP/8TP) Standard-based, one-button Bluetooth version 2.1+ EDR and Low Energy (LE) measurements Standard-based, one-button Bluetooth® 5 measurement; requires N9081A-2FP/2TP
Standard-based, one-button CMMB measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) Standard-based, one-button DVB-C (J.83 Annex A/C) measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) Standard-based, one-button J.83 Annex B measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) Standard-based, one-button, DTMB (CTTB) measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) Standard-based, one-button DVB-T/H measurements; supports analog baseband analysis with Option BBA (BBIQ inputs) Adds DVB-T2 measurements; requires 2FP/2TP Standard-based, one-button ISDB-T, ISDB-TB, and ISDB-TSB; supports analog baseband analysis with Option BBA (BBIQ inputs) Adds ISDB-Tmm measurements; requires 2FP/2TP
Adds one-button measurement for AM/FM/PM demodulation with metrics, AF spectrum, audio analysis, and tune-and-listen; supports analog output Adds FM Stereo and RDS; requires 2FP/2TP Adds one-button measurements for analyzing phase noise in frequency domain (log plot) and time domain (spot frequency) Adds one-button measurements for noise figure, gain, and related metrics; requires preamplifier to meet specifications; works with Keysight N400xA Series smart noise sources and 346 Series noise sources; supports U7227-Series USB preamplifier
Advanced NF measurement features including external LO control over GPIB/LAN/USB, and manual mode to simulate the legacy NF meter; requires 1FP/1TP Vector signal analysis; high-resolution, FFT-based spectrum and time-domain measurements, time gating, AM/FM/PM demodulation, statistical measurements; analog baseband analysis with Option BBA (BBIQ inputs); also supports Option EXM Adds flexible digital modulation analysis; general purpose digital modulation for 2-16FSK, 2-8PSK, and 16-1024QAM, as well as more than 15 additional formats; requires 1FP/1TP Pre-compliance conducted and radiated emission measurements

Find us at www.keysight.com

Page 14

Description

Fixed license

General purpose, continued MATLAB software N6171A-M01
N6171A-M02

N6171A-M03

SCPI command language compatibility Remote language compatibility 89600 vector signal analysis (VSA) software

N9062A-2FP
N9061A-1FP N9061A-2FP Not available

Transportable Additional information license

Not available Not available
Not available
Not available

Instrument Control Toolbox Instrument Control Toolbox Communications System Toolbox DSP System Toolbox Signal Processing Toolbox Instrument Control Toolbox Communications System Toolbox DSP System Toolbox Signal Processing Toolbox RF Toolbox Adds capability to emulate the R&S FSP/FSU/FSE spectrum analyzers

Not available Not available 89601B (transportable license is standard)

Adds capability to emulate the 8566/68 spectrum analyzers Adds capability to emulate the 856xE/EC spectrum analyzers Industry-leading measurement software for evaluating and troubleshooting signals in R&D; PC-based software supporting more than 40 measurement platforms, plus more than 75 signal standards and modulation types including MIMO analysis; www.keysight.com/find/89600_VSA

Related Literature
Keysight MXA signal analyzers
Publication title MXA X-Series Signal Analyzer N9020A, Brochure MXA X-Series Signal Analyzer N9020A, Data Sheet X-Series Measurement Applications, Brochure

Publication number 5989-5047EN 5989-4942EN 5989-8019EN

www.keysight.com/find/n9020a

Learn more at: www.keysight.com
For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus
Find us at www.keysight.com
This information is subject to change without notice. © Keysight Technologies, 2014 - 2018, Published in USA , September 18, 2018, 5989-4943EN

Page 15


Adobe PDF Library 15.0 Adobe InDesign CC 13.1 (Windows)