CE EMC TEST REPORT

Harris

Test Report

TianJin HuaLai Technology Co.,Ltd. WHCS1 WYZE Contact Sensor 2ANJHWHCS1 2ANJHWHCS1 whcs1

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=4078952
TEST REPORT
FCC ID: 2ANJHWHCS1 Product: WYZE Contact Sensor
Model No.: WHCS1 Additional Model: N/A
Trade Mark: WYZE Report No.: TCT181023E001 Issued Date: Oct. 31, 2018
Issued for: TianJin HuaLai Technology Co., Ltd. No.10 JinPing Road, Ya An Street, Nankai District Tianjin, China
Issued By: Shenzhen Tongce Testing Lab. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
TEL: +86-755-27673339 FAX: +86-755-27673332
Note: This report shall not be reproduced except in full, without the written approval of Shenzhen Tongce Testing Lab. This document may be altered or revised by Shenzhen Tongce Testing Lab. personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample.
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

TABLE OF CONTENTS

Report No.: TCT181023E001

1. Test Certification ..................................................................................... 3 2. Test Result Summary .............................................................................. 4 3. EUT Description....................................................................................... 5 4. General Information................................................................................. 6
4.1. Test Environment and Mode................................................................................. 6 4.2. Description of Support Units ................................................................................ 6
5. Facilities and Accreditations .................................................................. 7
5.1. Facilities ................................................................................................................. 7 5.2. Location ................................................................................................................. 7 5.3. Measurement Uncertainty..................................................................................... 7
6. Test Results and Measurement Data ..................................................... 8
6.1. Antenna Requirement ........................................................................................... 8 6.2. Conducted Emission ............................................................................................. 9 6.3. Radiated Emission Measurement ...................................................................... 10 6.4. 20dB Occupied Bandwidth ................................................................................. 19
Appendix A: Photographs of Test Setup Appendix B: Photographs of EUT

Page 2 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

1. Test Certification

Product:
Model No.: Additional Model: Trade Mark:
Applicant:

WYZE Contact Sensor WHCS1 N/A WYZE TianJin HuaLai Technology Co., Ltd.

Address:

No.10 JinPing Road, Ya An Street, Nankai District Tianjin, China

Manufacturer: TianJin HuaLai Technology Co., Ltd.

Address:

No.10 JinPing Road, Ya An Street, Nankai District Tianjin, China

Date of Test:
Applicable Standards:

Oct. 24, 2018 ­ Oct. 30, 2018 FCC CFR Title 47 Part 15 Subpart C Section 15.249

The above equipment has been tested by Shenzhen Tongce Testing Lab. and found compliance with the requirements set forth in the technical standards mentioned above. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties.

Tested By: Reviewed By: Approved By:

Jerry Xie Beryl Zhao
Tomsin

Date:

Oct. 30, 2018

Date:

Oct. 31, 2018

Date:

Oct. 31, 2018

Page 3 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

2. Test Result Summary

Requirement

CFR 47 Section

Antenna Requirement

§15.203

AC Power Line Conducted Emission

§15.207

Field Strength of Fundamental

§15.249 (a)

Spurious Emissions

§2.1053 §15.249 (a) (d)/ §15.209

Band Edge

§2.1053 §15.249 (d)/ §15.205

20dB Occupied Bandwidth

§2.1049 §15.215 (c)

Note:

1. Pass: Test item meets the requirement.

2. Fail: Test item does not meet the requirement.

3. N/A: Test case does not apply to the test object.

4. The test result judgment is decided by the limit of test standard.

Report No.: TCT181023E001
Result PASS N/A PASS PASS PASS PASS

Page 4 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

3. EUT Description

Product: Model No.: Additional Model: Trade Mark: Hardware Version: Software Version: Operation Frequency: Number of Channel: Modulation Technology: Antenna Type: Antenna Gain: Power Supply:

WYZE Contact Sensor WHCS1 N/A WYZE DWS3U-P01 V 0.0.0.9 907.8MHz, 908MHz, 908.2MHz 3
FSK
Internal Antenna 0.5dBi DC 3V

Operation Frequency Each of Channel Channel Frequency Channel Frequency Channel Frequency 0 907.8MHz 1 908MHz 2 908.2MHz

Note:

In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, and the selected channel see below:

Channel

Frequency

The lowest channel 907.8MHz

The middle channel 908MHz

The Highest channel 908.2MHz

Page 5 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

4. General Information
4.1. Test Environment and Mode

Operating Environment: Temperature: Humidity: Atmospheric Pressure:

25.0 C 54 % RH 1010 mbar

Test Mode: Engineering mode:

Keep the EUT in continuous transmitting by select channel

The sample was placed (0.8m below 1GHz, 1.5m above 1GHz) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages.

4.2.Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests.

Equipment

Model No.

Serial No.

FCC ID

Trade Name

/

/

/

/

/

Note:
1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer's requirements and conditions for the intended
use.

Page 6 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

5. Facilities and Accreditations

5.1. Facilities
The test facility is recognized, certified, or accredited by the following organizations:  FCC - Registration No.: 645098
Shenzhen Tongce Testing Lab The 3m Semi-anechoic chamber has been registered and fully described in a report with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files.  IC - Registration No.: 10668A-1 The 3m Semi-anechoic chamber of Shenzhen TCT Testing Technology Co., Ltd. has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
5.2. Location
Shenzhen Tongce Testing Lab Address: 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
Shenzhen, Guangdong, China TEL: 86-755-27673339
5.3. Measurement Uncertainty

The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %.

No. Item

MU

1

Conducted Emission

±2.56dB

2

RF power, conducted

±0.12dB

3

Spurious emissions, conducted

±0.11dB

4

All emissions, radiated(<1GHz)

±3.92dB

5

All emissions, radiated(>1GHz)

±4.28dB

6

Temperature

±0.1°C

7

Humidity

±1.0%

Page 7 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001
6. Test Results and Measurement Data
6.1.Antenna Requirement
Standard requirement: FCC Part15 C Section 15.203 15.203 requirement: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. E.U.T Antenna: The EUT antenna is internal antenna which permanently attached, and the best case gain of the antenna is 0.5dBi.
Antenna
Page 8 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

6.2.Conducted Emission

6.2.1. Test Specification

Test Requirement: Test Method: Frequency Range: Receiver setup:
Limits:

FCC Part15 C Section 15.207

ANSI C63.10:2013

150 kHz to 30 MHz

RBW=9 kHz, VBW=30 kHz, Sweep time=auto

Frequency range (MHz) 0.15-0.5 0.5-5 5-30

Limit (dBuV)

Quasi-peak

Average

66 to 56*

56 to 46*

56

46

60

50

Test Setup:

Test Mode: Test Procedure: Test Result:

Transmitting mode with modulation
1. The E.U.T and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm/50uH coupling impedance for the measuring equipment.
2. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refer to the block diagram of the test setup and photographs).
3. Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ANSI C63.10:2013 on conducted measurement.
N/A; Because the EUT is powered by the battery, so the item is not applicable.

Page 9 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

6.3. Radiated Emission Measurement

6.3.1. Test Specification

Test Requirement: Test Method: Frequency Range: Measurement Distance: Antenna Polarization:
Receiver Setup:

FCC Part15 C Section 15.209/ Part 2 J Section 2.1053

ANSI C63.10:2013

9 kHz to 25 GHz

3 m

Horizontal & Vertical

Frequency 9kHz- 150kHz
150kHz30MHz 30MHz-1GHz
Above 1GHz

Detector Quasi-peak Quasi-peak
Quasi-peak Peak Peak

RBW 200Hz 9kHz
120kHz 1MHz 1MHz

VBW 1kHz 30kHz
300kHz 3MHz 10Hz

Remark Quasi-peak Value Quasi-peak Value
Quasi-peak Value Peak Value
Average Value

Limit(Field strength of the fundamental signal):

Frequency 2400MHz-2483.5MHz

Limit (dBuV/m @3m) 94.00 114.00

Remark Average Value
Peak Value

Frequency

Limit (dBuV/m @3m)

Remark

0.009-0.490

2400/F(KHz)

Quasi-peak Value

0.490-1.705

24000/F(KHz)

Quasi-peak Value

1.705-30

30

Quasi-peak Value

Limit(Spurious Emissions):

30MHz-88MHz 88MHz-216MHz

40.0

Quasi-peak Value

43.5

Quasi-peak Value

216MHz-960MHz

46.0

Quasi-peak Value

960MHz-1GHz

54.0

Quasi-peak Value

Above 1GHz

54.0

Average Value

74.0

Peak Value

Emissions radiated outside of the specified frequency

bands, except for harmonics, shall be attenuated by at

Limit (band edge) :

least 50 dB below the level of the fundamental or to the

general radiated emission limits in Section 15.209,

whichever is the lesser attenuation.

1. The EUT was placed on the top of a rotating table 0.8

meters above the ground at a 3 meter chamber in

below 1GHz, 1.5m above the ground in above

1GHz. The table was rotated 360 degrees to

determine the position of the highest radiation.

Test Procedure:

2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted

on the top of a variable-height antenna tower.

3. The antenna height is varied from one meter to four

meters above the ground to determine the maximum

value of the field strength. Both horizontal and

vertical polarizations of the antenna are set to make

Page 10 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001
the measurement. 4. For each suspected emission, the EUT was arranged
to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading. 5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet.
For radiated emissions below 30MHz

Test setup:

30MHz to 1GHz

Above 1GHz (The diagram below shows the test setup that is utilized to make the measurements for emission from 1GHz to the tenth harmonic of the highest fundamental frequency or to 40GHz emissions, whichever is lower.)
Page 11 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

Test results:

PASS

Page 12 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

6.3.2. Test Instruments

Radiated Emission Test Site (966)

Name of Equipment

Manufacturer

Model

Serial Number

Calibration Due

Test Receiver

ROHDE&SCHW ARZ

ESVD

100008 Aug. 27, 2019

Spectrum Analyzer

ROHDE&SCHW ARZ

FSQ

200061 Aug. 27, 2019

Pre-amplifier

EM Electronics Corporation CO.,LTD

EM30265

07032613 Aug. 27, 2019

Pre-amplifier

HP

8447D 2727A05017 Aug. 27, 2019

Loop antenna

ZHINAN

ZN30900A

12024

Aug. 27, 2019

Broadband Antenna Schwarzbeck VULB9163

340

Aug. 27, 2019

Horn Antenna

Schwarzbeck BBHA 9120D

631

Aug. 27, 2019

Horn Antenna

Schwarzbeck BBH 9170

582

Aug. 27, 2019

Antenna Mast

Keleto

CC-A-4M

N/A

N/A

Coax cable (9KHz-1GHz)
Coax cable (9KHz-40GHz)

TCT

RE-low-01

N/A

Aug. 27, 2019

TCT

RE-high-02

N/A

Aug. 27, 2019

Coax cable (9KHz-1GHz)

TCT

RE-low-03

N/A

Aug. 27, 2019

Coax cable (9KHz-40GHz)

TCT

RE-high-04

N/A

Aug. 27, 2019

EMI Test Software

Shurple Technology

EZ-EMC

N/A

N/A

Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
international system unit (SI).

Page 13 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

6.3.3. Test Data

Field Strength of Fundamental

Frequency (MHz)
907.8

Emission PK/AV (dBuV/m)
43.2(PK)

907.8

29.7(AV)

908 908 908.2 908.2 907.8 907.8

43.5(PK) 28.9(AV) 42.8(PK) 30.1(AV) 44.1(PK) 29.4(AV)

908

44.8(PK)

908

30.5(AV)

908.2

43.3(PK)

908.2

29.6(AV)

Horizontal /Vertical
H H H H H H V V V V V V

Limits PK/AV (dBuV/m) 114 94 114 94 114 94 114 94 114 94 114 94

Margin (dB) -70.8 -64.3 -70.5 -65.1 -71.2 -63.9 -69.9 -64.6 -69.2 -63.5 -70.7 -64.4

Spurious Emissions

Frequency Range (9 kHz-30MHz)

Frequency (MHz) -----

Level@3m (dBV/m) -----

Limit@3m (dBV/m) -----

Note: 1. Emission Level=Reading+ Cable loss-Antenna factor-Amp factor

2. The emission levels are 20 dB below the limit value, which are not reported. It is deemed to comply with the requirement

Page 14 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Horizontal:

Frequency Range (30MHz-1GHz)

Report No.: TCT181023E001

Page 15 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Vertical:

Report No.: TCT181023E001

Note: Measurements were conducted in all channels (high, middle, low), and the worst case (middle channel) was
submitted only.
Page 16 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

Frequency Ant. Pol. (MHz) H/V

1815.60 H

2723.40 H

---

---

Peak reading (dBµV)
21.52
20.75
---

Above 1GHz

Low channel: 907.8MHz

AV reading (dBuV)

Correction Factor (dB/m)

Emission Level

Peak

AV

(dBµV/m) (dBµV/m)

Peak limit (dBµV/m)

AV limit (dBµV/m)

---

-3.94 17.58

---

74

54

---

0.52

21.27

---

74

54

---

---

---

---

---

---

Margin (dB)
-36.42 -32.73
---

1815.60 V

23.43

---

-3.94 19.49

---

74

54

-34.51

2723.40 V

20.58

---

0.52

21.10

---

74

54

-32.90

---

---

---

---

---

---

---

---

---

---

Frequency Ant. Pol. (MHz) H/V

1816.00 H

2724.00 H

---

---

Peak reading (dBµV) 22.14 20.97
---

Middle channel: 908MHz

AV reading (dBµV)

Correction Factor (dB/m)

Emission Level

Peak

AV

(dBµV/m) (dBµV/m)

Peak limit (dBµV/m)

AV limit (dBµV/m)

---

-3.98 18.16

---

74

54

---

0.57

21.54

---

74

54

---

---

---

---

---

---

Margin (dB)
-35.84 -32.46
---

1816.00 V

21.65

---

-3.98 17.67

---

74

54

-36.33

2724.00 V

20.39

---

0.57

20.96

---

74

54

-33.04

---

---

---

---

---

---

----

---

---

---

Frequency Ant. Pol. (MHz) H/V

1816.40 H

2724.60 H

---

---

Peak reading (dBµV)
22.25
20.78 ---

High channel: 908.2MHz

AV reading (dBµV)

Correction Factor (dB/m)

Emission Level

Peak

AV

(dBµV/m) (dBµV/m)

Peak limit (dBµV/m)

AV limit (dBµV/m)

---

-3.98 18.27

---

74

54

---

0.57

21.35

---

74

54

---

---

---

---

---

---

Margin (dB)
-35.73 -32.65
---

1816.40 V

21.72

---

-3.98 17.74

---

74

54

-36.26

2724.60 V

20.09

---

0.57

20.66

---

74

54

-33.34

---

---

---

---

---

---

---

---

---

---

Note:

1. Emission Level=Peak Reading + Correction Factor; Correction Factor= Antenna Factor + Cable loss ­ Pre-amplifier

2. Margin (dB) = Emission Level (Peak) (dBµV/m)-Average limit (dBµV/m)

3. The emission levels of other frequencies are very lower than the limit and not show in test report.

4. Measurements were conducted from 1 GHz to the 10th harmonic of highest fundamental frequency.

5. Data of measurement shown "---"in the above table mean that the reading of emissions is attenuated more than 20

dB below the limits or the field strength is too small to be measured.

Page 17 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

Band Edge Requirement

Low channel: 907.8 MHz

Frequency Ant. Pol. (MHz) H/V

Peak reading (dBµV)

902

H

27.63

902

H

---

---

---

---

AV reading (dBuV)

Correction Factor (dB/m)

Emission Level

Peak

AV

(dBµV/m) (dBµV/m)

Peak limit (dBµV/m)

AV limit (dBµV/m)

---

-4.20 23.43

---

74

---

20.31 -4.20

---

16.11

---

54

---

---

---

---

---

---

Margin (dB)
-50.57 -37.89
---

902

V

27.90

---

-4.20 23.70

---

74

---

-50.30

902

V

---

21.33 -4.20

---

17.13

---

54

-36.87

---

---

---

---

---

---

---

---

---

---

High channel: 908.2MHz

Frequency Ant. Pol. (MHz) H/V

928

H

928

H

Peak reading (dBµV)
23.32
---

AV reading (dBuV)

Correction Factor (dB/m)

Emission Level

Peak

AV

(dBµV/m) (dBµV/m)

Peak limit (dBµV/m)

AV limit (dBµV/m)

---

-4.20 19.12

---

74

---

21.63 -4.20

---

17.43

---

54

Margin (dB)
-54.88 -36.57

---

---

---

---

---

---

---

---

---

---

928

V

25.48

---

-4.20 21.28

---

74

---

-52.72

928

V

---

20.05 -4.20

---

15.85

---

54

-38.15

---

---

---

---

---

---

---

---

---

---

Note:

1. Emission Level=Peak Reading + Correction Factor; Correction Factor= Antenna Factor + Cable loss ­ Pre-amplifier

2. Margin (dB) = Emission Level (Peak/Average)(dBµV/m)-(Peak/Average) limit (dBµV/m)

3. The emission levels of other frequencies are very lower than the limit and not show in test report.

4. Measurements were conducted from 1 GHz to the 10th harmonic of highest fundamental frequency.

5. Data of measurement shown "---"in the above table mean that the reading of emissions is attenuated more than 20 dB

below the limits or the field strength is too small to be measured.

Page 18 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001

6.4. 20dB Occupied Bandwidth

6.4.1. Test Specification
Test Requirement: Test Method: Limit:

FCC Part15 C Section 15.215(c)/ Part 2 J Section 2.1049
ANSI C63.10: 2013
N/A
1. According to the follow Test-setup, keep the relative position between the artificial antenna and the EUT.
2. Set to the maximum power setting and enable the EUT transmit continuously.
3. Use the following spectrum analyzer settings for 20dB Bandwidth measurement. Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel; RBW1% of the 20 dB bandwidth; VBWRBW; Sweep = auto; Detector function = peak; Trace = max hold.
4. Measure and record the results in the test report.

Test setup:

Test Mode: Test results:

Transmitting mode with modulation PASS

6.4.2. Test Instruments

RF Test Room

Equipment

Manufacturer Model Serial Number Calibration Due

Spectrum Analyzer

Agilent

N9020A MY49100060 Aug. 27, 2019

Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
international system unit (SI).

Page 19 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

6.4.3. Test data
Test Channel Lowest Middle Highest
Test plots as follows:

20dB Occupy Bandwidth (kHz)
105.0
103.1
104.2

Report No.: TCT181023E001

Limit -------

Conclusion PASS PASS PASS

Page 20 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Lowest channel

Report No.: TCT181023E001

Middle channel

Highest channel

Page 21 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001
Appendix A: Photographs of Test Setup
Product: WYZE Contact Sensor Model: WHCS1
Radiated Emission
Page 22 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Appendix B: Photographs of EUT
Product: WYZE Contact Sensor Model: WHCS1 External Photos

Report No.: TCT181023E001

Page 23 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001
Page 24 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001
Page 25 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Product: WYZE Contact Sensor Model: WHCS1 Internal Photos

Report No.: TCT181023E001

Page 26 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001
Page 27 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com

Report No.: TCT181023E001
*****END OF REPORT*****
Page 28 of 28
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com


Microsoft Office Word 2007 Microsoft Office Word 2007