HC600-SUG 6L 185043061D

Test

Fisher & Paykel SleepStyle600

Change CPAP Pressure Settings - Adjusting your machine with a Clinician Setup Manual

Healthcare Provider Manual

PDF preview unavailable. Download the PDF instead.

sleepstyle-600-techs-guide
Healthcare Provider Manual
To be retained by Clinician/Dealer
Manuel du prestataire de services
À conserver par le clinicien/revendeur
Manual del distrubudor
Debe quedar en poder del médico o distribuidor
Manuale per il personale sanitario
Da lasciare in custodia al medico o al fornitore
Handleiding voor de handelaars in zelfzorgproducte
Blijft bij de slaaplab/de handelaar
Handbuch für Fachhändler
Verbleibt beim Arzt/Anbieter

English

for home use and sleep lab titration

TABLE OF CONTENTS

Healthcare Provider Manual
To be retained by Clinician/Dealer

1 SYSTEM SETUP..........................................................................................................A2 1.1 Before you begin........................................................................... ......A2 1.2 Setting the prescribed pressure .......................................................A2 1.3 Equipment required............................................................................A2 1.4 Adjusting the pressure........................................................................A2
2 CONTROLS AND DISPLAY...........................................................................................A3 2.1 Pressure Set Menu............................................................................. A3 2.2 Clinician Menu.................................................................................. A4 2.3 ThermoSmartTM Technology Adjustments....................................... A4
3 CONTROLS AND DISPLAY SUMMARY...........................................................................A5 3.1 Controls and Display Summary..........................................................A5
4 MAINTENANCE SCHEDULE.........................................................................................A6 4.1 Maintenance by user....................................................................... ....A6 4.2 Maintenance by clinician.....................................................................A6
IMPORTANT INFORMATION..........................................................................................A6

A- 1

1 SYSTEM SETUP
This guide refers to the SleepStyleTM 600 CPAP Series as the "device".
1.1 BEFORE YOU BEGIN
Before using this setup guide, ensure that you have read and understood the Operating Manual. You must be familiar with the symbols, definitions, safeguards and operating instructions which apply to the device.
1.2 SETTING THE PRESCRIBED PRESSURE
The prescribed patient pressure should be set with the same type of CPAP tube and mask that the patient will be using. Variations in mask exhaust hole size and tube diameter or length will change the pressure at the patient end.
1.3 EQUIPMENT REQUIRED - The patient's tube and mask. - A pressure measuring device with a minimum range of 0 to 20cmH20. - A length of pressure tubing. - "T" adaptor if the mask does not have a pressure port.
1.4 ADJUSTING THE PRESSURE
(NB) Please make yourself familiar with 2.1 Pressure Set Menu, before attempting to make pressure adjustments.
1. If the mask has a pressure port, connect the pressure tubing from the mask to the manometer.
2. If the mask does not have a pressure port then insert a "T" adaptor between the tube and mask. Connect the pressure tube to the "T" adaptor.
3. Connect one end of the patient tube to the mask and the other to the device. Refer to the "Important Parts of The Device" section of the SleepStyleTM 600 CPAP Series Operating Manual.
4. Switch the device on. The device will start at its set pressure.
5. The pressure can then be adjusted by pushing down the and button at the same time for 3 seconds.
*· Set the altitude as appropriate to the current location by pressing and buttons. (Set the altitude units (feet or metres) to your preference, refer to "Patient Menu - Additional Settings" in the Operating Manual)
· Select the button to set/view the pressure. Pressure is adjusted with the and buttons.
6. To change the set pressure, seal the cushioned part of the mask (for the Oracle mask seal the end of the mask tube) so that air flow is only through the bias flow hole, then adjust the pressure until the prescribed pressure is achieved.
7. Once the prescribed pressure is achieved the bias flow hole should be momentarily blocked so that the "no flow" pressure can be measured. This ensures that the prescribed pressure can be reset if the patient mask and tube are not available.
8. Record the prescribed pressure and "no flow" pressure in the "Important Information" section of this manual.
* Manual adjustment of altitude is not featured on units where there is the Automatic Altitude Adjustment/Leak Compensation feature
A- 2

<

<

<

<

English

2 CONTROLS AND DISPLAY
Press to activate ramp
Increase setting Decrease setting Press to step through options

Press & hold to switch device on/off

<

<

2.1 PRESSURE SET MENU This menu allows the pressure and the altitude to be set. To access this menu hold down the and buttons simultaneously for 3 seconds. Once you have entered the menu, press the button to step through the options:
· Set altitude
To adjust the altitude setting, press and buttons to desired value. · Adjust set pressure
To adjust the pressure setting, press and buttons to desired value. · Press to confirm settings. NOTE: Manual adjustment of altitude is not featured on units where there is
the Automatic Altitude Adjustment/Leak Compensation feature
A- 3

<

<

< <

<

2.2 CLINICIAN MENU This menu allows access to compliance and software information. To access this menu press and hold the and buttons simultaneously for 3 seconds.
· Press the button to step through the options. C1: Display total complied time and clear compliance data · Here the machine shows that the patient has used in total 200 hours since first used or last cleared. · Press and buttons together to clear data. C2: Display software version · The software version is displayed as a number following the shown symbol.
2.3 THERMOSMARTTM TECHNOLOGY ADJUSTMENTS This device has been designed for optimal patient comfort and offers the unique heated breathing tube technology ThermoSmartTM. ThermoSmartTM technology allows for the delivery of optimal (higher and customized) levels of humidity to the patient, independent of ambient temperature. This device can be adjusted on two levels (ThermoSmartTM Comfort and ThermoSmartTM Climate setting) to achieve optimal comfort. - ThermoSmartTM Comfort setting regulates humidity and temperature output. - ThermoSmartTM Climate setting offers an extended range of temperature and humidity combinations a patient can choose from in the ThermoSmartTM Comfort setting. The device is preset to a medium setting at both levels suitable for most nasal interface users. It is recommended that patients start therapy at these default settings and adjust for comfort from there. Exception: patients using an oral interface should have their device set to setting "3"on the ThermoSmartTM Climate setting. Section 5.4 and section 8 of the Operating Manual contain comprehensive information on ThermoSmartTM Technology and how to adjust it.
A- 4

English

3 CONTROLS AND DISPLAY SUMMARY
3.1 CONTROLS AND DISPLAY SUMMARY
Pressure Set Menu: To access press both buttons simultaneously
Clinician Menu: To access press both buttons simultaneously

<< <

< <<
<

PRESSURE SET MENU
FROM HUMIDITY DEFAULT DISPLAY THE PRESSURE SET MENU ALLOWS THE ALTITUDE LEVEL TO BE ADJUSTED BEFORE SETTING PRESSURE.

ThermoSmartTM Comfort Setting (default)

HOLD FOR 3 SEC

ALTITUDE SETTING

or INCREASE/DECREASE
ALTITUDE LEVEL

SET PRESSURE CM H20

or

INCREASE/DECREASE PRESSURE

RETURN TO DEFAULT

NOTE: Manual adjustment of altitude is not featured on units where there is the Automatic Altitude Adjustment/Leak Compensation feature

CLINICIAN MENU
FROM HUMIDITY DEFAULT DISPLAY, THE CLINICIAN MENU ALLOWS ACCESS TO COMPLIANCE AND SOFTWARE INFORMATION

ThermoSmartTM Comfort Setting (default)

HOLD FOR 3 SEC

C1: TOTAL COMPLIANT TIME

CLEAR COMPLIANCE

+

C2: SOFTWARE
VERSION

RETURN TO DEFAULT

A- 5


Acrobat Distiller 4.0 for Macintosh