Lumens-LOGO

Lumens VC-TR40N Auto Tracking Camera

Lumens-VC-TR40N-Auto-Tracking-Camera-PRODUCT

Important To download the latest version of Quick Start Guide, multilingual user manual, software, or driver, etc., please visit Lumens https://www.MyLumens.com/support

Package Contents

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-1

Product Appearance

I/O functions IntroductionLumens-VC-TR40N-Auto-Tracking-Camera-FIG-2

NO.ItemFunction Descriptions
1.Main camera lensHD camera lens
2.Panoramic lensPanoramic camera lens
3.USB3.0 PortThe USB port is for connecting to the USB port of the computer and providing USB signal images
4.HDMI outputHDMI output (Audio output supported)
5.3G-SDI output3G-SDI output(Audio output supported)
6.Audio In3.5 mm LINE IN
7.Network portNetwork cable port, supporting PoE (IEEE802.3af) power supply
8.RS-232 inputRS-232 input port, at most 7 cameras can be connected in a serial connection
9.RS-232 outputRS-232 output port, at most 7 cameras can be connected in a serial connection
10.DC 12 V power PortDC supply connecting port

Description of LED indicator

StatusPowerStandby
Startup in progressGreenlightOrange light
In useGreenlightNo indicator
In standby modeNo indicatorOrange light
 Tracking / Framing mode Flickering green light Flickering green light

Instruction for installation

Instruction for installation of TR40 and TR40,AT

  • Note: The VC-TR40 comes in a standard version and an AT version. The AT version requires different firmware for upgrades, which can be downloaded from the Lumens website.
  • The AT version differs only in the tracking function; all other functions are the same.

Introduction

  • The TR40 and TR40, AT have different Tracking functions. You can decide which version will suit your needs.
  • a. VC-TR40: To track or frame the target in the tracking zone.
  • Available modes: Everywhere Tracking, Stage Tracking, Partition Tracking, Auto Framing, Partition Framing
  • b. VC-TR40, AT: Offers a choice between Presenter and Audience modes.
  • Presenter Mode: The camera tracks the target within the tracking zone.
  • Audience Mode: The camera starts tracking when it detects the target standing up.
  • Refer to the  5.2.4 Tracking page for more information

Scenario for TR40 and TR40, AT

  • a. Applicable distance range of VC-TR40/TR40,AT : 2 -14 m.
  • Best tracking target distance recommended: 8 m
  • The default maximum tracking distance is 12m, but it can changed to 14m via the webpage.
  • Refer to 5.2.12 System Settings – Control
  • b. Mounting height: 2 – 3 m, best height recommended: 2.4 mLumens-VC-TR40N-Auto-Tracking-Camera-FIG-3
  • <Note> To maintain the best tracking results, please avoid having images of people on posters, screens, monitors or TVs in the background

Scenario for VC-TR40,AT

  • VC-TR40, AT*1: Install at the back of a room to capture the presenter.
  • VC-TR40, AT*2: Install at the front of a room to capture the audience.Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-4

Preparation before installation

  • Installation and connection of HD cameras require special skills. To install by yourself, please follow the necessary steps, ensure steady and tight installation of the device, and pay attention to your safety to avoid any accidents.
  • Ensure the safety of the installation environment. Please do not install the device on an unstable ceiling or in a place where the device is in danger of falling to avoid any accident.
  • Please check whether the accessories in the box are complete or not. Please contact the supplier for any shortage, and make sure to keep the accessories in the box intact.
  • Please choose a proper place for the installation of the camera in advance. Please determine an installation place according to the following requirements
  • a. Confirm the position for the object to be captured.
  • b. Confirm whether the camera is set at a proper distance from other light sources.

Instruction for installation

I would like to install the camera on the desk

  • Please install the machine on a flat desk
  • Do not grab the camera head by hand when handling the device
  • Do not rotate the camera head by hand. Improper rotation may result in the breakdown of the cameraLumens-VC-TR40N-Auto-Tracking-Camera-FIG-5

I would like to install the camera on the ceiling/wall/TV stand

  • Lumens can provide the following optional accessories. Please contact your Lumens distributer if needed for purchase
  • VC-WM14 3 in-1 Folding Bracket
  • VC-WM15 Ceiling Mounted Bracket
  • For installation of brackets, please download the VC-WM14/VC-WM15 Quick Installation Guide from the Lumens website
  • Install on the TVLumens-VC-TR40N-Auto-Tracking-Camera-FIG-6
  • Install on the ceilingLumens-VC-TR40N-Auto-Tracking-Camera-FIG-7
  • Install on the wallLumens-VC-TR40N-Auto-Tracking-Camera-FIG-8
  • Note: The camera will only track the target within the panoramic scene. Please ensure that the panoramic view covers the entire area you want to shoot.

Camera Size

  • Length x Width x Height: 190 x 138 x 185 mm
  • Weight: 1.3 KgLumens-VC-TR40N-Auto-Tracking-Camera-FIG-9

Dimensions of the bottom of the machine

  • The camera can be mounted on a 1/4”-20 UNC PTZ tripod deck by using the lock holes on the bottom of the tripodLumens-VC-TR40N-Auto-Tracking-Camera-FIG-10

Connecting devicesLumens-VC-TR40N-Auto-Tracking-Camera-FIG-11

<Remark> Network cable port, supporting PoE (IEEE802.3af) power supply

RS-232 connection (up to 7 Lumens cameras)Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-12

RS-232 pins definition instructionsLumens-VC-TR40N-Auto-Tracking-Camera-FIG-13

Remote Control and Setting Menu

Remote ControlLumens-VC-TR40N-Auto-Tracking-Camera-FIG-14

serial number
projectillustrate
1.PowerPower Switch
2.Preset¡ Numeric Keys 0 – 9: Click to call the preset

¡ Preset: Appoint an ID (0 ~ 9) to save the current position data

¡ Reset: Appoint an ID (0 ~ 9) to delete the

current position data

3.MenuDisplay OSD menu
4.Pan/ Tilt/ Enter¡ Pan/Tilt: Move the lens

¡ Home-Enter: Go back to the main page / Execute

5.InfoStatus information
6.Zoom¡ Fast: Adjust the image size

¡ Slow: Fine-tune image size

7.Focus¡ Auto: Autofocus

¡ Manual: Enable Manual Focus

¡ Far/Near: Adjust the focal length in Manual

8.Auto Tracking¡ On/Off: Enable/Disable Auto Tracking

¡ Full: Full body tracking

¡ Upper: Half-body tracking

¡ Switch: Switch tracking object

9.L/R Direction SetL/R Direction / Normal
10.MirrorRotate the image (OFF / Mirror / Flip / Rotate)
11.Camera selectChoose Camera ID 1 ~ 3
12.Back LightTurn on/off the backlight compensation
13.Pan/Tilt ResetClear the Pan/Tilt setting
14.Auto Framing¡ On/Off: Enable/Disable auto framing

¡ Trigger: Manual framing correction
Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-50VC-TR40, AT does not support the Framing function.

Setting Menu

<Remark> Press [MENU] on the remote control to enter the setting menu; the bold underlined values in the following table are defaults.

1st Level Major Items2nd Level Minor Items3rd Level Adjustment ValuesFunction Descriptions
ExposureModeFull Auto/ Shutter Pri/ Iris Pri/ Manual/ White BoardExposure mode setting
Exposure Comp.On/OffTurn on/off Exposure Comp.
Exposure Comp. Level 

-6~C~4

Adjustable after Exposure Comp. is activated
Spot LightOn/OffTurn on/off the Spot Light
Spot Light PositionX(0~6)Y(0~4)Adjustable after Spot Light is activated
Anti-Flicker50Hz/ 60Hz/ OffEnable/ Disable Anti-Flicker
 

Shutter Speed

60/30mode50/25modeAdjustable when the Exposure mode

is set to Shutter Pri or Manual

1/10000~1/25
Iris LevelF1.6~C~F14/ CloseAdjustable when the Exposure mode

is set to IRIS Pri or Manual

Gain Limit8~30dBMax. limit value of electron gain
Gain Level0~30dBAdjustable when the Exposure mode

is set to Manual

WDROff/ 1/ 2/ 3WDR settings
  1. AutoSelect the color temperature mode 1. 4000k ~ 7000k

2.  3200k

3.  5800k

4.  1700k ~ 10000k

5.  1700k ~ 10000k

6. Custom 7. 2800k

  2. Indoor
  3. Outdoor
 Mode4. One Push WB
White Balance5. ATW

6. Manual 7.Sodium Lamp

 One Push TriggerENTEROne push trigger
 Manual Red0~ C~127Adjustable when the white balance

mode is set to Manual

 Manual Blue0~ C~127Adjustable when the white balance mode is set to Manual
TrackingTypeAuto Tracking / Auto FramingVC-TR40, AT does not support the Framing function.
Picture2D NROff/ 1/ 2/ 32D noise reduction
3D NROff/ Low/ Typ/ Max3D noise reduction
Image ModeDefault/ CustomThe user may customize his/her desired image mode
Brightness0~ A ~15Adjustable when the Image Mode is set to Custom
Hue0~ A ~15Adjustable when the Image Mode is set to Custom
Saturation0~ A ~15Adjustable when the Image Mode is set to Custom
Gamma0~ A ~3Adjustable when the Image Mode is set to Custom
Sharpness0~A~14Adjustable when the Image Mode is set to Custom
Pan TiltPan/Tilt LimitOn/OffTurn on/off the angle limit setting
1st Level Major Items2nd Level Minor Items3rd Level Adjustment ValuesFunction Descriptions
ZoomPan Right Limit0~170Limit the right angle
Pan Left Limit170~0Limit the left angle
Tilt UP Limit0~90Limit the upward angle
Tilt Down Limit30~0Limit the downward angle
Pan FlipOn/OffAfter it is activated, the Pan command will be reversed
Tilt FlipOn/OffAfter it is activated, the Tilt command will be reversed
Preset Speed5/ 25/ 50/ 80/ 120 deg/secSet the rotation speed of the cradle head when the Preset is executed
PTZ Speed CompOn/OffAfter it is activated, the Pan/Tilt moving speed will vary from the zoom position
D-Zoom Limitx1~x12Set the D-zoom limit
D-EffectMirrorOff/ Mirror/ Flip/ Mirror+FlipSet the mode at which the image is turned
Auto FocusAF SensitivityLow/ Middle/ HighFor AF triggering speed, the higher the sensitivity is, the faster the AF is triggered
AF FrameCenter/ Full Frame/ AutoAF frame setting, when the Center is set as AF frame, focusing will be on the center of the screen. When Full Frame was set as AF frame, focusing will be calculated based on the full screen
EthernetDHCPOn/OffEnable/Disable the dynamic host configuration
IP Address192.168.100.100Configurable when DHCP is set to Off
Subnet mask255.255.255.0
Gateway192.168.100.254
AudioAudio EnableOn/OffTurn on/off the audio output
Audio InLine In/ Mic In 
Audio Volume0~A~10Volume Setting
Audio DelayOn/OffWhen the audio is not synchronized with the video, enable this function to set the audio delay time
Audio Delay Time(ms)-10~-500msSet audio delay time
Encode Sample Rate48 KHz(AAC)Set the encode type and sample rate
SystemPromptOn/OffTurn on/off the prompt information on the display
IR ReceiveOn/OffTurn on/off the infrared reception When it is Off, the remote control will not be able to control the camera. At this moment, turn off and then turn on

the power to restore control of the remote control.

1st Level

Major Items

2nd Level Minor Items3rd Level Adjustment ValuesFunction Descriptions
 IR Select1/ 2/ 3Camera IR Select setting must be the same setting as the Camera Select of the remote control to control the camera
Tracking Led StatusOn/ OffWhen enabled, the LED on the front panel will flash green in a slow blinking while the camera is tracking.
LanguageEnglish/ Chinese 
Initial PositionLast MEM/ 1st PresetAfter turning on the camera, you can select the lens to be returned to Last  MEM or 1st Preset <Remark> 1st Preset =Preset 0
Motionless PresetOn/OffWhen the function is enabled, the screen will Freeze when the Preset is executed. Freeze will be released after the Preset is completed
Privacy ModeOn/OffEnable/Cancel Privacy Mode After the function is enabled when the camera is turned off via the remote control or software, the lens will automatically turn to the bottom right to ensure the user’s privacy
ProtocolVISCASupporting VISCA protocol
Baud Rate9600/38400Choose the transmission speed of the

control signal

VISCA Address1~7The camera ID address can be

assigned. Select 0 for automation.

Output Mode1080p 60/50/30/25 720p 60/50/Choose the output resolution
Factory Reset)On/OffResume the factory default setting
Status  Display the current setting status

Network Function Settings Description

Connecting Camera to Network

Connecting to Internet

Two common connection methods are shown below

  1. Connecting via switch or routerLumens-VC-TR40N-Auto-Tracking-Camera-FIG-15
  2. To connect directly through the network cable, the IP address of the computer should be changed so that it is on the same network segment as the camera E.g.:
    • The factory-preset default IP address of the camera is 192.168.100.100. The computer IP address must be set with the same network segment, such as 192.168.100.101 so that the computer can be connected correctly to the cameraLumens-VC-TR40N-Auto-Tracking-Camera-FIG-16
    • Change network settingsLumens-VC-TR40N-Auto-Tracking-Camera-FIG-17

Using the Browser to View the Images

  • Open the browser, and enter the IP address of the camera in the address bar E.g.: http://192.168.100.100 (default IP address)
  • Enter the administrator’s account and password

<Remark> For the first-time login, please refer to5.2.10System Settings – User to change the default passwordLumens-VC-TR40N-Auto-Tracking-Camera-FIG-18

Using RTSP Player to View the Images

  • Free software can be used for RTSP connection, such as VLC, Quick Time, and PotPlayer

RTSP connection address formats are as follows:

  • RTSP Stream 1 => rtsp://camera IP:8557/h264
  • RTSP Stream 2 => rtsp://camera IP:8556/h264
  • RTSP Stream3 => rtsp://camera IP:8553/h264
  • Stream 3 is for the Panoramic image.

If password authentication is enabled, the RTSP connection address is as follows:

  • rtsp://Username: Password@VC IP address: port/h264
  • To enable the  password authentication function, please refer to5.2.8 System Setting – Network
  • Example: Open the VLC software, click [Open Network Streaming], and enter the URL: rtsp://192.168.100.150:8557/h264.Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-19

Web Page Menu Function Description

Login Screen

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-20
NoItemFunction Descriptions
1User Login AccountEnter user login account (default: admin)
2User PasswordEnter user password (default: 9999)

<Remark> For the first-time login, please refer to 5.2.10 System  Settings – User to change the default password

3Remember the user account and passwordSave the user login account and password to the browser. When you log in next time, there is no need to re-enter them
4LanguageSupporting English/Traditional Chinese/Simplified Chinese
5LoginLog into the administrator screen on the website

Live Video – PTZ Control

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-21
NoItemFunction Descriptions
 1Camera ID/locationDisplay camera ID/location Please refer to 5.2.7 System Settings – Output Setting
2Preview windowDisplay the screen currently captured by the camera
3Preset settingSelect the number first and then select SAVE or LOAD
4Pan/Tilt settingAdjust the Pan/Tilt position of the camera screen
5ZoomZoom In/Zoom Out ratio
6AF/MFSwitch AF/MF
7Pan/ Tilt SpeedAdjust the horizontal/vertical moving speed of the lens
8Zoom speedAdjust the zoom speed
9Auto TrackingEnable/Disable Auto Tracking
10Auto FramingEnable/Disable Auto Framing
11Camera SettingPlease refer to 5.2.3 Live Video – Camera Setting for related settings
 12Enlarge the preview window Zooming in/out the preview image

Live Video – Camera Setting

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-22
NoItemFunction Descriptions
1ExposureMode: Select exposure mode (Full Auto/Shutter Pri/Iris Pri/Manual/ White Board)

Gain Level: Adjust the gain level (adjustable only under the “Manual”)

Gain Limit: Adjust the gain limit (adjustable only under the “Manual”)

Exposure Comp. Level: Select exposure compensation level

WDR: Set the level of wide dynamic range (WDR) to obtain better images

Iris Level: Adjust the size of the aperture (adjustable only under the “Manual” or “Aperture Priority”

Shutter Speed: Adjust the shutter speed (adjustable only under the “Manual” or “Shutter Priority”

Anti-Flicker: Enable Anti-flicker function(adjustable 50Hz or 60Hz)

2White BalanceLumens-VC-TR40N-Auto-Tracking-Camera-FIG-23

Mode: Select the color temperature mode

Open Push WB: Single color temperature execution adjustment (adjustable only under the “One Push WB”

Manual Red/Blue: Manually adjust blue/red color temperature

3FocusLumens-VC-TR40N-Auto-Tracking-Camera-FIG-24

AF Sensitivity: Set automatic focus sensitivity

AF Frame: Set automatic focus range

4MirrorLumens-VC-TR40N-Auto-Tracking-Camera-FIG-25

Mirror: Set image mirroring

Flip: Set image flip

5Pan Tilt Zoom(PTZ)Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-26

Pan/Tilt limit: Enable, and set the pan/tilt limit

Preset Speed: Set the rotation speed of the cradle head when the Preset is executed Initial Position: Set the camera lens to return to Last MEM or 1st Preset after POWER ON <Remark> 1st Preset = Preset 0

D-Zoom Limit: Set the D-Zoom Limit

PTZ Speed Comp: After it is activated, the Pan/Tilt moving speed will vary from the zoom position

Initial Position: Set the camera lens to return to the last operated position or the first preset position after POWER ON

Motionless Preset: When the function is enabled, the screen will Freeze when the Preset is executed. Freeze will be released after the Preset is completed

6.PhotoLumens-VC-TR40N-Auto-Tracking-Camera-FIG-27

 2D noise reduction: 2D noise reduction settings

3D noise reduction: 3D noise reduction settings

Image Mode: The user may customize his/her desired image mode

Hue: Hue adjustment of the image; Adjustable when the image mode is set to Custom

  Saturation: Saturation adjustment of the image; Adjustable when the image mode is set to Custom

Brightness: Brightness adjustment of the image; Adjustable when the image mode is set to Custom

Gamma: Gamma Level adjustment; Adjustable when the image mode is set to Custom

Sharpness: Sharpness adjustment of the image; Adjustable when the image mode is set to Custom

7PTZ ControlGo back to the PTZ Control page

Tracking

(This Tracking section is for the VC-TR40. For the TR40, AT version, please refer to section 5.2.4.A)Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-28

NoItemFunction Descriptions
1Camera ID/locationPlease refer to 5.2.7 System Settings – Output Setting to display camera

ID/Location

2Preview the main windowDisplay the screen currently captured by the main camera lens

<Remark> Left-click the detected person on the screen to switch the tracking object. The tracking object is depicted with a green bounding box

3Panoramic preview

window

Display the screen currently captured by the panoramic lens
4People CountDisplay the number of people on the screen automatically calculated by the system
5Auto TrackingStart/Stop Auto Tracking

<Remark> Auto Tracking / Auto Framing (Select one only)

6Auto FramingStart/Stop Auto Framing

The camera will automatically detect the locations of people, and automatically adjust the zoom to the most appropriate size to accommodate all the participants according to the change in the number of people at the conference

<Remark>Auto Tracking / Auto Framing (Select one only)

7Zoom ratioZoom In/Zoom Out ratio
8Pan/Tilt settingAdjust the Pan/Tilt position of the camera screen

<Remark> When Auto Tracking / Auto Framing is enabled, PTZ settings are not supported

9Take TurnSwitch the targets one by one from left to right. It will be switched once the button is pressed
10Target IdDisplay Target Id
11GesturingOn/ Off Gesturing function.

Support the following gesture, the tracking target will automatically switch when the speaker raises both hands.Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-29

12Designated IDPress it to activate this function. You can switch the ID by clicking the targeted frame with the mouse.
13Tracking ModeSet the Tracking Mode (Everywhere Tracking/Stage Tracking/Center

Stage/Partition Tracking/Auto-Framing/Partition Framing)

14SensitivitySet tracking sensitivity
15Tracking SpeedSet tracking speed
16Target Lost TimeSet a delay for taking action after a tracking object is lost
17Target Lost ActionSet the action after a tracking object is lost
18Auto-trigger zoneWhen people walk into the trigger zone you have set, the auto-tracking will be turned on.
19Tracking Mode SettingVC-TR40 supports 6 kinds of tracking mode
19.1Settings – Everywhere trackingLumens-VC-TR40N-Auto-Tracking-Camera-FIG-30

Body Size: Set Full/Half Body

Head Position: Set the head position of the person on the screen

Block Area: Click into the Edit mode, frame by holding the left mouse button, and set the block area

Tracking Zone: Set a specific tracking range.

19.2Settings – Stage TrackingLumens-VC-TR40N-Auto-Tracking-Camera-FIG-31

Body Size: Set Full/Half Body

Head Position: Set the head position of the person on the screen

Block Area: Click into the Edit mode, frame by holding the left mouse button, and set the block area

Stage Zone: Click into the Edit mode, frame by holding the left mouse button, and determine the tracking range

19.3Settings – Partition TrackingSet Partition Tracking. Up to 4 zones can be set When a person enters the zone of a partition, the camera switches to the partition. Tracking is not performed in the zone, but everywhere outside the partition Please refer to 5.2.4.2 Partition Tracking for the setting stepsLumens-VC-TR40N-Auto-Tracking-Camera-FIG-32
  Body Size: Set Full/Half Body

Head Position: Set the head position of the person on the screen

Block Area: Click into the Edit mode, frame by holding the left mouse button, and set the block area

Partition Edit: Edit, save partition positions, and preview the partition image.

Click to enlarge the partition image, and then click the enlarge icon to cancel the preview.

Partition amount: Display the total stored number of Partition.

Starting Partition: Initiating the partition position

19.4Setting – Center StageEnable Center Stage allows the camera to keep the target in the center of the frame frame-based image in the PTZ lens after calling a new preset.Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-33

Center Stage: on/off

Head Position: Set the head position of the person on the screen

19.5Settings – Auto

-Framing

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-34

Body Size: Set Full/Half Body

Head Position: Set the head position of the person on the screen Block Area: Click into the Edit mode, frame by holding the left mouse button, and set the block area

Framing Size: Tight / Medium / Wide

19.6Setting – Partition FramingLumens-VC-TR40N-Auto-Tracking-Camera-FIG-35Partition Edit: Edit, save partition positions, and preview the partition image.

Click to enlarge the partition image, and then click the enlarge icon to cancel the preview.

Partition amount: Display the total stored number of Partition.

Stage

  1. Select [Stage] for Tracking Mode, and clickLumens-VC-TR40N-Auto-Tracking-Camera-FIG-36 to access the settingsLumens-VC-TR40N-Auto-Tracking-Camera-FIG-37
  2. SelectLumens-VC-TR40N-Auto-Tracking-Camera-FIG-38 Zone to enter Edit mode, and click the left mouse button to frame it (yellow frame) in the panoramic preview window, determining the area and moving range. After framing, use the mouse to click the frame line to move or delete it.Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-39
  3. SelectLumens-VC-TR40N-Auto-Tracking-Camera-FIG-40 to click the left mouse button to frame it (red frame) in the panoramic preview window, and set the block areaLumens-VC-TR40N-Auto-Tracking-Camera-FIG-41
  4. After framing, clickLumens-VC-TR40N-Auto-Tracking-Camera-FIG-42 on the setting
  5. ClickLumens-VC-TR40N-Auto-Tracking-Camera-FIG-43 to enable the Stage feature

Partition

  1. Select [Partition] for Tracking Mode, and clickLumens-VC-TR40N-Auto-Tracking-Camera-FIG-36 to access the settingsLumens-VC-TR40N-Auto-Tracking-Camera-FIG-44
  2. ClickLumens-VC-TR40N-Auto-Tracking-Camera-FIG-45 to enable the Partition edit, click the left mouse button to frame it (orange frame) in the panoramic preview window, determine the area, and clickLumens-VC-TR40N-Auto-Tracking-Camera-FIG-46 to save. The partition icon below will be changed to the saved positionLumens-VC-TR40N-Auto-Tracking-Camera-FIG-47
  3. If you need to set other partitions, please continue framing, and then clickLumens-VC-TR40N-Auto-Tracking-Camera-FIG-46 to save
    • <Remark> Overlapping partition positions may cause abnormal tracking behaviorLumens-VC-TR40N-Auto-Tracking-Camera-FIG-48
  4. ClickLumens-VC-TR40N-Auto-Tracking-Camera-FIG-43 to enable the Partition feature

Tracking (For VC-TR40,AT version)Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-49

NoItemFunction Description
1Camera ID/ locationDisplay the camera ID and location. Refer to 5.2.7 System-Output
2Preview windowDisplay the image from the Lens.
 3Panoramic preview windowDisplay the image from the Panoramic Lens.
Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-50Left-clicking the target with the green icon on head by the mouse to track the desired target in the panoramic scene
 4 ModePresenter: Track the target on the stage.

Audience: Track the audience when an audience does the corresponding movement.

5Auto TrackingOn / OffAuto Tracking    
6Zoom ratioZoom In/Out
7Pan/Tilt settingPan / Tilt the camera to your desired angle.

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-50When the auto-tracking is enabled, the PTZ is uncontrollable

8Take TurnChange the tracking target from left to right in order one at a time after clicking the button.

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-50Not supported in Audience mode.

9Setting AreaTo display the Stage zone and Blocking zone you have drawn in a panoramic field.
10Basic setting-PresenterLumens-VC-TR40N-Auto-Tracking-Camera-FIG-51

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-52Designated ID: The targets detected in the panoramic scene will display a green indicator for easier identification.

Sensitivity: Low/Middle/High.

Target lost time: Set how long the camera will take to act after losing the target

Target lost Action: what action will be done after losing the target: Back to start position/Stay in the last position/PTZ back to the center and wide

  Tracking speed: Low/Middle/High

Outside Stage: Whether the camera will keep tracking after leaving the Stage area.

Body Size: Full/Upper

Head position: Set the individual’s head will be in which position in the scene. Low/ Middle/ HighLumens-VC-TR40N-Auto-Tracking-Camera-FIG-53

Area Setting Profiles and Synchronized: Save or Load the zone profile you have drawn.

Stage Zone: Click it then start editing. Use the left button of the mouse to draw a tracking zone in the panoramic scene. The camera will then track the target in this area.

Blocking Zone: Click it then start editing. Use the left button of the mouse to draw a blocking zone in the panoramic scene. The camera will then not track the target in this area.

Remark: <Please note that the Stage and Blocking zone can overlap if needed.>

10Basic Setting-AudienceLumens-VC-TR40N-Auto-Tracking-Camera-FIG-54

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-52Designated ID: The targets detected in the panoramic scene will display a green indicator for easier identification.

While tracking, click on a different indicator to switch to a different target.

Sensitivity: Low/Middle/High

Stand Up Lost Time: After triggering, how long the camera will keep tracking the target?

Target Lost Action: What the camera will do after losing the target?

PTZ back to the enter and wide/ Stay in the last position/ Back to start position.

  Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-55

Area Setting Profiles and Synchronized: Save or Load the zone profile you have drawn.
Blocking Zone: Click it then start editing. Use the left button of the mouse to draw a blocking zone in the panoramic scene. The camera will then not track the target in this area.

11Commands-Press enter

(To be used with Lumens LC300)

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-56

Noted: To use the camera with the Lumens LC300 intelligent director function, the checkbox above needs to be checked.

Send Times: Once/ Always Send

Up/Down Stage: Configure that the camera will only track the target when the individual is on stage.

Detect Type: Single Object / Mutlple Object.

Behavior Detect:

Normal: Will not send the PTZ start and Stop command.

PTZ     Start-Stop: The PTZ Stop and PTZ Start command will be sent.Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-57

11Command-Audience (To be used with Lumens LC300)Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-58

Noted: To use the camera with the Lumens LC300 intelligent director function, the checkbox above needs to be checked.
Send Times: Once / Always send

12Advanced-Audience/Presenter

(To be used with Lumens LC300)

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-59

Noted: To use the camera with the Lumens LC300 intelligent director function, the setting here needs to be configured correctly.

Connect by: Network/ Serial port

Protocol: UDP/ TCP

Director IP: Enter the LC300 IP address.

   Director Port: 52382
13People CountDisplays how many people have been detected in the panoramic scene.

How to use the VC-TR40, AT with the Lumens LC300 Intelligent Director function

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-60
NoItemFunction Description
1Target lost actionAllows you to choose which scene will be displayed when the target is lost
2Presenter/Audience SettingsAllows you to choose which scene will be displayed and what action will trigger the scene change.
3PriorityWhen two events are triggered, you can choose which one should take priority.
4On/OffEnable or disable the Intelligent Director.
5ApplyApply the settings
Please remember to complete the Command and Advanced sections’ settings to link the VC-TR40, AT, and LC300.Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-61

Audio

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-62
NoItemFunction Descriptions
1Audio EnableSelect to enable the Audio function

Audio In: Set Line In / Mic In

Encode sample rate: Encode type and sample rate (48KHz(AAC)

Volume: Adjust Audio Volume

2Audio DelayAfter checking the box, set the audio delay time (10 ~ -500 ms)
3Apply/CancelApply/Cancel Audio Setting

Streaming

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-63
NoItemFunction Descriptions
1Streaming 1/ Streaming 2Supporting 2-way streaming output
2Streaming parameter settingPlease refer to 5.2.6.1 Streaming Parameter Setting for relevant settings
3RTSPSelect to enable RTSP

Enable/Disable Multicast

It is suggested to enable Multicast when the number of users online watching the live image simultaneously is more than 4

Enable/Disable Password Authentication

RTSP connection format can be found in 5.1.3 Using RTSP Player

To view the Images

The username/password is the same as the web login password of the camera, please refer to 5.2.10 System Settings – User to add/modify account information

4RTMP/ RTMPSCopy the RTMP web address provided by the RTMP service platform and paste it to the RTMP connection address to publish the camera images on the RTMP service platform

To upload to YouTube for live streaming, please refer to 5.2.5 Audio to turn on the audio function

5SRTCheck to enable and set SRT streaming

After the SRT streaming is opened, it will be connected automatically upon startup

The port number must be set in the range above 1024 with a maximum value of 9999

<Remark> The following port is to be used by the camera. The setting of the said port may not connect correctly 8554, 8555, 8557, 8080, 9090, 1935

The delay time is 20 to 8000 microseconds. The default value is 120 microseconds

6NDIFor VC-TR40N only. Please refer to 5.2.7 Streaming – NDI.

Streaming parameter setting

FunctionStreaming 1Streaming 2
Encode FormatH.264
Resolution1080p / 720p720p
Bit rateRange2,000~20,0002,000~20,000
Factory Default7,0003,000
Rate ControlCBR / VBR
Frame RateSetting according to the supported resolution
Group of PicturesSetting according to the supported resolution

Stream – NDI (For VC-TR40N only)

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-64
NoItemFunction Descriptions
1Camera ID/ LocationDisplaying ID/location according to [System] > [Output] settings
2Group NameThe group name can be modified here and set with Access Manager – Receive in NDI Tool

If no group is assigned, the machine belongs to the Public. As the default of Access Manager includes Public, Studio Monitor can discover this machine.

If a group is assigned, but this group is not added to Access Manager, Studio Monitor cannot discover this machine.

If a group is assigned and this group is added to Access Manager, Studio Monitor can discover this machine.

<Remark> The name can contain commas (,) to distinguish different groups

Example: “default, 123, ABC” means this machine belongs to three groups at the same time (default/ 123/ ABC)

3NDI|HXHX2/HX3 can be set on VC-TR40N

n   HX2: HX2 is supported

n   HX3: HX3 is supported (Stream 1/ 2 will be disabled.)

4MulticastMulticast Settings.

It is recommended to enable this feature when there are more than 4 viewers online simultaneously

5Discovery ServerCheck to enter the Server IP address
6ApplyAfter the setting has been modified, click this button to apply the settings

System – Output Setting

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-65
NoItemFunction Descriptions
1Camera nameChange the camera name here

Supporting 1 – 32 characters for the camera name

Please mix uppercase and lowercase letters or numbers for characters. Special symbols such as “/” and “space” cannot be used

<Remark> Modifying this field will modify the Onvif device name synchronously

2Camera LocationModify the location of the camera, such as Room 1

Supporting 1 -32 characters for the camera location

Please mix uppercase and lowercase letters or numbers for characters. Special symbols such as “/” and “space” cannot be used

<Remark> Modifying this field will modify the Onvif device location synchronously

3ResolutionSet the resolution of the camera After switching the resolution, the camera will restart. Please refresh the browser
4HDMI formatSelect YUV444/RGB
5Privacy Mode (UVC)Enable/Cancel Privacy Mode After the function is enabled when the camera is turned off via the remote control or software, the lens will automatically turn to the bottom right to ensure the user’s privacy
6Apply/CancelApply/Cancel Setting

System – Network

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-66
NoItemFunction Descriptions
1DHCPNetwork setting of the camera. Change of setting is available when the DHCP function is closed
2HTTP port numberSet HTTP port. The default Port value is 80
3HTTPS port numberSet HTTPS port. The default Port value is 81
4Apply/CancelApply/Cancel Setting

System – Date & Time

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-67
Function Descriptions
Display the current camera/PC date and time, and set the display format and synchronization way

When Manually Set is selected for [Time Settings], Date & Time can be customized

System – User

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-68
Function Descriptions
Add/Modify/Delete user account

Supporting 4 – 32 characters for username and password

Please mix uppercase and lowercase letters or numbers for characters. Special symbols or the underlined cannot be used

Authentication Mode: Set the new account management permissions

 User TypeAdministrator (Admin)Operator (Operator)Viewer (Viewer) 
View imagesVVV
SettingsVVX
Account managementVXX

System Settings – Control

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-69
NoItemFunction Descriptions
1ProtocolSupporting VISCA protocol
2Baud RateChoose the transmission speed of the control signal as 9600/38400
3VISCA addressThe camera ID addresses 1 ~ 7 can be assigned. Select 0 for automation
4Tracking LED statusEnable/Disable the LED in the front panel flick when tracking is triggered.
5Tracking DistanceChange the longest tracking distance to either 12 or 14 meters.

(The camera will reboot itself after switching)

6Apply/CancelApply/Cancel Setting

Maintenance

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-70
NoItemFunction Descriptions
1Firmware UpgradeSelect the firmware file, and click [Upgrade] to update the firmware.

<Remark>Update takes about 2-3 minutes.

<Remark> Please do not operate or turn off the power of the device during the update to avoid firmware update failure.

2Factory ResetReset all configurations to factory default settings

Except for the Network Setting after reset

3System SettingsSave setup parameters as a Profile, and users can download and upload

camera setup parameters

 

4

 

Error Log

If the camera operates abnormally, please export the error log and provide it to Lumens for confirmation
5Reboot·   Reboot: Conduct the reboot immediately.

·   Daily Reboot Time: Choose the desired exact time for the camera to reboot. <Remark: Can only be configured when SNTP is on.>

·   Reboot Timing: Choose how many hours later the camera will reboot:

1HR~24HR.

About

Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-71
Function Descriptions
Display the firmware version, serial number, and other related information of the camera
For technical support, please scan the QR code at the bottom right.

Troubleshooting

This chapter describes problems you may encounter while using VC-TR40. If you have questions, please refer to related chapters and follow all the suggested solutions. If the problem still occurs, please contact your distributors or the service center.

No.ProblemsSolutions
1.Boot without power signal1. Make sure you have plugged in the power cord.

2. When using a PoE connection, ensure that the power supply supports PoE (IEEE802.3af) hubs

2.There is no image output from the camera1. Check the power supply or PoE supply functions.

2. Confirm the output signals are in streaming output.

3. Confirm whether the camera resolution can be used together with the monitor equipment

4. Replace the cables and make sure they are not faulty.

3.The camera image is severely delayedPlease use 1080p or 720p 60/50 fps rather than 25/30 fps signals.
 

4.

RS-232 cannot be controlled1. Confirm the connection is correct (RS-232 In/ Out)

2. Please make sure the Baud rate setting is the same as the control equipment

5.Whether the Internet can be

used for operation

Please refer to Chapter 5 Network Function Setting

Description of the Internet Usage

6.The ONVIF software cannot find the machinePlease make sure that [System] > [Output] > [Camera ID] / [Location] on the web page uses only English letters or numbers. The ONVIF software cannot find the machine if you use special characters and space.
7.The camera does not save the relevant parameters (PTZ, AWB …) after rebootPlease make sure that the Initial Position is set to Last MEM from the settings menu or web page

1. Setting Menu: System – Initial Position

2. Web page: Live View-Setting    Camera Setting – PTZ – Initial Position

 

8.

How to log in to the portal when you forget your

account password

Please contact your Lumens distributor or service center
9.Tracking performance is inconsistent, likely due to long distances.Ensure that the distance between the tracking target and the camera is within the recommended range.

Refer to 5.2.12    System Settings – Control to adjust the maximum tracking distance. You can select between 12 and 14 meters.

10.Tracking Performance is PoorIf the distance is within the recommended range, check the following factors that might affect performance:

1.  The environment is too dark.

2.  The individual is too obscured or covered by other objects in a panoramic view.

3.  The camera is installed too high (above 3 meters).

Safety Instructions

Always follow these safety instructions when setting up and using the VC-TR40 PTZ Video Camera:

  1. Operation
    • Please use the product in the recommended operating environment, away from water or sources of heat
    • Do not place the product on a tilted or unstable trolley, stand, or table.
    • Please clean the dust on the power plug prior to usage. Do not insert the product’s power plug into a multiplug to prevent sparks or a fire.
    • Do not block the slots and openings in the case of the product. They provide ventilation and prevent the product from overheating.
    • Do not open or remove covers, otherwise it may expose you to dangerous voltages and other hazards. Refer all servicing to licensed service personnel.
    • Unplug the product from the wall outlet and refer servicing to licensed service personnel when the following situations happen:
    • If the USB port becomes damaged or frayed.
    • If liquid is spilled into the product or the product has been exposed to rain or water.
  2. Installation
    • For security considerations, please make sure the standard mount you use is in line with UL or CE safety approbations and installed by technician personnel approved by agents.
  3. Storage
    • Do not place the product where the cord can be stepped on as this may result in fraying or damage to the lead or the plug.
    • Unplug this product during thunderstorms or if it is not going to be used for an extended period.
    • Do not place this product or accessories on top of vibrating equipment or heated objects.
  4. Cleaning
    • Disconnect all the cables before cleaning and wipe the surface with a dry cloth. Do not use alcohol or volatile solvents for cleaning.
  5. Batteries (for products or accessories with batteries)
    • When replacing batteries, please only use similar or the same type of batteries.
    • When disposing of batteries or products, please adhere to the relevant instructions in your country or region for disposing of batteries or products.

Precautions

  • Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-72This symbol indicates that this equipment may contain dangerous voltage which could cause electric shock. Do not remove the cover (or back). No user-serviceable parts inside. Refer servicing to licensed service personnel.
  • Lumens-VC-TR40N-Auto-Tracking-Camera-FIG-73This symbol indicates that there are important operating and maintenance instructions in this User Manual with this unit.

FCC Warning

This equipment has been tested and found to comply with the limits for a Class A digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

IC Warning

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of Industry Canada.

EN55032 CE Warning

  • Operation of this equipment in a residential environment could cause radio interference.
  • Warning: Operation of this equipment in a residential environment may cause radio interference

Extron IP Link Compatible

  • Extron has developed and tested an IP Link driver for this product. Using IP Link technology, this device can be monitored, controlled, and supported over a standard Ethernet network.
  • To enable IP Link network connectivity and control, you must install and configure an IP Link-enabled device such as a MediaLink controller or IP Link Ethernet control interface. For more information, please see www.extron.com/iplc”.

Supplier’s Declaration of Conformity

47 CFR § 2.1077 Compliance Information

  • Manufacturer: Lumens Digital Optics Inc.
  • Product Name: VC-TR40
  • Model Number: PTZ Video Camera
  • Responsible Party – U.S. Contact Information
  • Supplier: Lumens Integration, Inc.
  • 4116 Clipper Court, Fremont, CA 94538, United States
  • e-mail support@mylumens.com

FCC Compliance Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference,
  2. this device must accept any interference received, including interference that may cause undesired operation

Copyright Information

Copyrights © Lumens Digital Optics Inc. All rights reserved

  • Lumens is a trademark that is currently being registered by Lumens Digital Optics Inc.
  • Copying, reproducing, or transmitting this file is not allowed if a license is not provided by Lumens Digital Optics Inc. unless copying this file is for backup after purchasing this product.
  • To keep improving the product, the information in this file is subject to change without prior notice.
  • To fully explain or describe how this product should be used, this manual may refer to names of other products or companies without any intention of infringement.
  • Disclaimer of warranties: Lumens Digital Optics Inc. is neither responsible for any possible technological, editorial errors or omissions, nor responsible for any incidental or related damages arising from providing this file, using, or operating this product.

Documents / Resources

Lumens VC-TR40N Auto Tracking Camera [pdf] User Manual
VC-TR40, VC-TR40N, VC-TR40N Auto Tracking Camera, VC-TR40N, Auto Tracking Camera, Tracking Camera

References

Leave a comment

Your email address will not be published. Required fields are marked *