PT-4-BLE Patient Tags

by Guard RFID (part of HID)

Description

The PT-4-BLE is an active tag featuring 12 months of battery life. It advertises its location using Bluetooth Low Energy (BLE) signals. Patient Tags work with the GuardRFID® AllGuard® software to provide real-time location services. The AllGuard software can be configured to control doors to speed patient flow to scheduled medical examinations or protect patients from suspicious activity.

Features

Specifications

Product PT-4-BLE
Part Number 61-10116
Software Compatibility AllGuard Server 8.1 or later, HID Bluzone™
Bluetooth Standard Bluetooth 5.2
Frequency Band 2400-2483.5 MHz
Battery Life 12 months
Beacon Interval 12 seconds
Compatible with Mother Tags Yes
Dimensions 28 x 14.5 mm (1.1 x 0.57")
Weight 6.62 g (0.23 oz)
Waterproof Yes, designed to IP68
Operating Temperature -30°C to 50°C (-22° F to 122°F)
Humidity 0-100%
Regulatory FCC Part 15.249, IC, UL-294
Warranty 12 months

Regulatory Compliance

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

This device complies with part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Cet appareil est conforme à la spécification RSS-210 d'Industry Canada. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne peut engendrer aucune interférence et (2) il doit accepter toute interférence qu'il reçoit, y compris celles qui peuvent altérer son fonctionnement.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment.

FCC ID: VZK-PT4 | IC ID: 9937A-PT4

Accessories

PT-1BLF Mounting Band - Extra Strength

Part Number: 61-12102

  • Wide, heavy-duty material for added strength.
  • Features a special pre-applied, permanent locking snap closure that easily fastens.
  • Latex-free, waterproof.
  • Dimensions: 381 x 17.3 mm (15 x 0.7"), white.
  • Pack size: 100 pack.

Description of visual: The PT-4-BLE tag attached to a wide, white, heavy-duty mounting band with a blue center.

Tag Wristbands

Part Number: 61-12046

  • Soft, comfortable, watch-style wristbands.
  • Length: 10" long, with a removable clasp.
  • Made of Thermoplastic Polyurethane (TPU) material that is anti-bacterial and designed to withstand repeated exposure to hot water and steam.

Description of visual: The PT-4-BLE tag integrated into a purple, watch-style wristband.

Models: PT-4-BLE Patient Tag, PT-4-BLE, Patient Tag, Tag