Specifications

  • Powered by No. 7 battery
  • Wireless radio frequency
  • Static load power consumption is less than 100 mW
  • Operating voltage: 3VDC
  • Operating current: 50mA
  • Standby current: 10uA
  • Remote control distance: 10m (Open and barrier-free)
  • Operating temperature: -16°C to +45°C
  • Storage temperature: -20°C to 55°C (Without battery)
  • Storage humidity: 10 – 90% RH (without condensation)
  • Operating humidity: 20 – 90% RH (without condensation)
  • Atmospheric pressure: 86 – 106KPa

Product Usage Instructions

Key Function Schematic Diagram

Refer to the key function schematic diagram for the functions of
each key on the remote control.

Remote Control Pairing

To pair the remote control:

  1. Press key (0) within 15 seconds of power-on to initiate
    pairing.
  2. Long press key (0) for about 2 seconds. The buzzer will beep
    three times to indicate successful pairing.

Function Introduction

The remote control functions include:

  • Ceiling Fan On/Off and Pairing
  • Light Dimming
  • Light On/Off
  • Anti-theft Mode
  • Timed Shutdown
  • Power Failure Memory

Supplementary Instructions

  1. If not in use for a long time, remove the battery.
  2. Replace the battery when remote control distance becomes short
    or fails frequently.
  3. For indoor and dry environment use only.

FAQ

Q: What should I do if the remote control distance is short or
it fails frequently?

A: Replace the battery in the remote control promptly.

Q: Can I use the product in outdoor environments?

A: No, the product is recommended for indoor and dry environment
use only.

Q: How do I pair the remote control with multiple
controllers?

A: Follow the remote control pairing instructions for each
additional controller you wish to pair with the remote.

www.lifudw.cwomw. u .com Instruction Manual
LF-SCR001-433
Ceiling Fan Remote Control
Features
Slim and lightweight body Each remote control can be paired with multiple controllers
Applications
Straight blade ceiling fan lights, invisible ceiling fan lights Office lighting, commercial lighting, decorative lighting, and store lighting
Main parameters
Powered by No. 7 battery Wireless radio frequency Static load power consumption is less than 100 mW

Parameter characteristics

Input and output parameters
Operating voltage Operating current Standby current Remote control distance

3VDC 50mA 10uA 10m (Open and barrier-free)

Operating temperature and conditions

Operating temper aSttuorrage temperature Storage humidity Operating humidity Atmospheric pressure

-16 – +45 -20 – 55(Without battery) 10 – 90%RH (without condensation) 20 – 90%RH (without condensation) 86 – 106KPa

1

2

Key function schematic diagram
Remote control pairing
Ceiling Fan On/Off and Pairing : key (0) is the ceiling fan on/off and pairing key. When the ceiling fan is on, press this key to turn off the ceiling fan.Within 15 seconds after power -on, long press this key for about 2 seconds to pair the remote control, and the buzzer will beep three times to indicate that the pairing is successful.
Function introduction
1. Ceiling Fan and Light Off: key (1) is ceiling fan and light off key. Press this key to turn off the ceiling fan and light. 2. Ceiling Fan Speed Setting : key (2) is the ceiling fan speed setting key. If the ceiling fan is currently off, pressing this key can turn on the ceiling fan and it will run at the corresponding wind speed setting. In natural wind mode, pressing this key can cancel the natural wind. The timing function will not be can celled by pressing the speed setting key in the timing mode. 3.Natural Wind: key (3) is the natural wind key of the ceiling fan. When the ceiling fan is on, press this key to run the ceiling fan in natural wind mode , and the ceiling fan automatically cycles from gear 1 to 6.When the ceiling fan is off, press this key to turn the ceiling fan on, and the default setting is clockwise rotation in natural wind mode. 4. Direction of the Ceiling Fan:key (4) is the direction of the ceiling fan key.When the ceiling fan is off, pressing this key can change the original running direction of the ceiling fan, and it will run in the changed direction in the next start up. When the ceiling fan is on, press this key to switch the ceiling fan to the reverse rotation of the current running direction, and the gear remains unchanged. 5. Silent Mode: key (5) is the buzzer on/off key. Press this key to turn off the buzzer. After that, pressing any other key on the remote control will not produce a buzzer sound. Press this key again and the buzzer will sound again. If it is in the silent mode, there will be a sound prompt for pairing and ceiling fan light failure.
3

6. Light Dimming: key (6) is the light dimming key. The ‘-‘ key is used to lower the brightness level, and the ‘+’ key is used to raise the brightness level.
7.Light On/Off: key (7) is the light on/off key. Press this key to turn on/off the light.
8.Anti-theft Mode: key (8) is the anti-theft key.After pressing this key, the anti-theft mode is turned on. After the ceiling fan light is silent for 4 hours, it will automatically turn on the ceiling fan at gear 1 and turn on the light ,the buzzer will respond once. After running for 10 minutes, the ceiling fan light will enter the silent state again. This cycle repeats. If the ceiling fan light is currently in anti-theft mode, pressing any key will cancel the anti-theft mode.
9. Timed Shutdown : key (9) is the 1H/4H/8H timing function key. When the ceiling fan or light is on, press the key of a certain duration to turn on the corresponding timing function , and the ceiling fan and light will be turned off when the timing function is finished.
10.Power Failure Memory : before power failure , the ceiling fan will save the on/off status , speed setting , running direction, buzzer on/off status, and light on/off status data. The next power-on will continue to run according to the data before the power failure.
Supplementary instructions
1. If not in use for a long time, please remove the battery. 2. When the remote control distance becomes short or remote control fails frequently, replace the battery in time. 3. For indoor and dry environment use only.
Transportation and storage
1. Suitable transportation means: vehicles, boats and aeroplanes.
2. In transit, it is necessary to prepare awnings for rain or sun protection. Moreover, please keep civilized loading and unloading to prevent the vibration or impact as much as possible.
3. The storage shall conform to the standard of Class I environment . When the products have been stored for more than 6 months, please re-test them firstly. Do not use them unless they are tested to be qualified.
Announcements
1. Please use the products according to its parameters in the specification, otherwise the products may malfunction. 2. Using any incompatible light fixtures or those that have not been certified may cause. fire, explosion or other risks. 3.Man-made damage is beyond the scope of he warranty service.
Disclaimer
The above information is subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
4

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
RF Exposure Statement
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Documents / Resources

Lifud LF-SCR001-433 Ceiling Fan Remote Controller [pdf] Instruction Manual
LFSCR001, 2BMEN-LFSCR001, 2BMENLFSCR001, LF-SCR001-433 Ceiling Fan Remote Controller, LF-SCR001-433, Ceiling Fan Remote Controller, Fan Remote Controller, Remote Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *