LED2WORK LEANLED II Basic-Line LED Surface Mounted Light Instruction Manual

LED2WORK-logo

LED2WORK LEANLED II Basic-Line LED Surface Mounted Light

LED2WORK-LEANLED-II-Basic-Line-LED-Surface-Mounted-Light-product

Specifications

  • Model: LEANLED II Basic-Line
  • Power Consumption: ~3.8 W to ~34.6 W
  • Regulation: 2014/35/EU
  • Part Number Variants: 111010-41 to 111010-57

Structure of safety and supplementary information

Important instructions are marked with signal words or symbols in this operating manual. Some signal words denote the degree of the potential risk of injury. Colours and the different shades of grey and triangular symbols visually underline the degree of danger.

  • DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • CAUTION: Indicates a potentially hazardous situation which, if not avoided, could result in minor or slight injury.
  • ATTENTIONIndicates a potentially hazardous situation which, if not avoided, could result in property damage.
  • NOTEGives you additional information for the safe and efficient use of the product. Refers to compliance with these operating instructions.
  • CE marking: confirms conformity with applicable standards and regulations.

Proper use

The light is used for illumination. A continuous operation is admissible. For connection values, see luminaire label and/or “Technical data”. The supply cable is connected to the light via an M12 plug connection.

The safety information and all other information in this manual must be followed. Read the entire operating manual carefully before mounting and turning on.

For safe operation

The operating parameters of the LED light specified on the type plate must correspond to the supply parameters of the machine or of the switched-mode power supply. Operate the light only in a mounted status.

CAUTION
Under no circumstances may the light be covered with cloths, foils or similar. Object distance the light-emitting surface should be at least 10 cm (3.94″).

ATTENTION

  • Machines can emit voltage spikes due to various factors. These voltage spikes in the power supply via machines should be avoided: Only use regulated 24V DC switched-mode power supplies, not transformers with rectifiers, as these can give rise to voltage spikes due to inductance.
  • Hot plugging should be avoided (connection of the light to a power supply which is already connected to the mains), since this can lead to the destruction of the LED light.
  • LED lights react sensitively to high voltage transients if the necessary PSU are incorrectly selected. Choose a power supply solution that is adapted to your interference environ-ment.

Note

Lights without grounding and with conductive housing supplied via safety extra low voltage (SELV – protection class III), smallest discharge currents may occur when contact is made. According to DIN VDE 0701 – 0702, this discharge current must be limited to a maximum of 0.5 mA. All corresponding products from LED2WORK GmbH fall significantly below this specification.

Safety information

WARNING
Installation of electrical equipment may only be carried out by qualified electricians. Follow the five safety rules according to DIN VDE 0105. Failure to do so may result in damage to the LED light, as well as fire or other hazards.

DANGER

  • Danger of electric shock!
  • Disconnect before working on the device or load. Ensure to disconnect all circuit breakers that supply dangerous voltages to the device or load, when doing so. Even when the device is switched off, the load is not galvanically isolated from the mains.

ATTENTION

  • Only use the device if it is completely free of faults, and with safety and awareness in mind. If warnings or symbols are attached to the light, they must not be removed.

Assembly / Mounting

Check the LED light before installation to ensure it is complete and shows no signs of damage. Do not use the light or accessories if they are damaged, as there is a risk of injury.
The LED light comes fully assembled. The light is attached via the two included luminaire holder sets 2 and 3. As option there are this mounting accessories:

Product no.
Spring clip, steel galvanized, pair 210200-07
Spring clip with magnet, pair 210200-08
Light holder set (spare part) 210200-18
Light holder Mounting adapter for mounting set 210200-18, 1 pair 210200-19
Light holders, stainless steel (V2A), 1 pair 210200-34

CAUTION

When mounting the light, make sure that the luminaire is fastened securely and stably. If the light falls down, its weight poses a risk of injury!

Connection

Suitable connection material, cables and accessories can be found in the accessory range of LED2WORK.

ATTENTION

Take care of the applicable national/international specifications and regulations when connecting the light. Use the wire cross-sections appropriate for your line distance and your purpose of use.

PIN assignment of the M12 connector is as follows:

LED2WORK-LEANLED-II-Basic-Line-LED-Surface-Mounted-Light-fig (1)

Schematic drawing of M12 plug

LED2WORK-LEANLED-II-Basic-Line-LED-Surface-Mounted-Light-fig (2)

Possible variants of the M12 connector

PIN assignment 

NOTE

  • PIN 3 = 0V DC. 24V DC for supply can be connected to PIN1 or PIN 4. It is not necessary to assign both PINs (PIN 1 and PIN 4) at once!
  • The light is not equipped with a ON/OFF switch. Usually you switch the light ON or OFF via external switches of machines or systems.
  • ATTENTION In case of undervoltage supply (< 24V DC), i.e. insufficient voltage in the power network, the luminous flux is reduced.

Maintenance and Care

The LED light is maintenance-free. Do not make any alterations to the light (except according to the mounting information contained in this manual).

Drawings

LED2WORK-LEANLED-II-Basic-Line-LED-Surface-Mounted-Light-fig (3)

light holderLED2WORK-LEANLED-II-Basic-Line-LED-Surface-Mounted-Light-fig (4)

LED2WORK-LEANLED-II-Basic-Line-LED-Surface-Mounted-Light-fig (5)

ATTENTION
Do not open the light!

  • The LED light sources mounted in the light are connected to the luminaire housing in a special way (thermal coupling) and may react sensitively to electrostatic discharges (ESD). That is the reason why repairs may only be carried out by the manufacturer or by persons authorised and qualified by the manufacturer.
  • Turn off the light before cleaning and let it cool down completely. Clean the outside of the light with a soft, dry and clean cloth. To remove excess dirt, moisten the cloth with water. Never use aggressive cleaning agents, as these may cause discolouration of the housing.

ATTENTION

No liability is assumed for damages resulting from the use of unsuitable cleaning agents.

Warranty

We supply a full warranty for the product for 5 years from the date of purchase. This warranty applies for fault-free working under proper use and in accordance with the operating instructions. During the warranty period defects and faults in the product will be rectified free of charge if they are proven to be caused by material, processing or design errors. If the purchaser complains of a material defect, he bears the burden of proof to demonstrate that the product was already defective upon receipt.

NOTE

The warranty does not extend to defects caused by wear, negligence or improper use. Further claims, in particular claims for compensation for damage that did not occur on the LED light itself, are excluded.

Disposal

ATTENTION
The light must be disposed of at a suitable disposal site designated for recycling of electrical and electronic equipment in accordance with local, national regulations. (WEEE-Reg.-Nr. DE 38003906)

Customer service

If you have any problems or questions concerning this product, please contact us!

By phone: +49 7231 44920-00 Monday to Thursday 8 am to 12 midday and 1 pm to 4:30 pm Friday 8 am to 12 midday and 1 pm to 3 pm
By email: info@led2work.com

Technical data

  • Connection values 24V DC (no voltage stabilization)
  • Class of protection III
  • Beam angle (optics) 120°
  • LED lifetime > 60.000 h (L80/B10)
  • Operating temperature 0… +45°C
  • System of protection IP54
  • Technical safety inspection DIN EN 62471
  • Light colour 5700K 3-step MacAdam
  • Colour rendering Ra ≥ 80
LED light Product no. Length A Max. current Max. power consumption
LEANLED II Basic-Line, clear cover 111010-41 180 mm 0.16 A ~3.8 W
LEANLED II Basic-Line, clear cover 111010-42 260 mm 0.24 A ~5.7 W
LEANLED II Basic-Line, clear cover 111010-43 350 mm 0.32 A ~7.6 W
LEANLED II Basic-Line, clear cover 111010-44 520 mm 0.48 A ~11.6 W
LEANLED II Basic-Line, clear cover 111010-45 760 mm 0.72 A ~17.3 W
LEANLED II Basic-Line, clear cover 111010-46 1020 mm 0.96 A ~23.1 W
LEANLED II Basic-Line, clear cover 111010-47 1520 mm 1.44 A ~34.6 W
LEANLED II Basic-Line, opal white diffuser cover 111010-51 180 mm 0.16 A ~3.8 W
LEANLED II Basic-Line, opal white diffuser cover 111010-52 260 mm 0.24 A ~5.7 W
LEANLED II Basic-Line, opal white diffuser cover 111010-53 350 mm 0.32 A ~7.6 W
LEANLED II Basic-Line, opal white diffuser cover 111010-54 520 mm 0.48 A ~11.6W
LEANLED II Basic-Line, opal white diffuser cover 111010-55 760 mm 0.72 A ~17.3 W
LEANLED II Basic-Line, opal white diffuser cover 111010-56 1020 mm 0.96 A ~23.1 W
LEANLED II Basic-Line, opal white diffuser cover 111010-57 1520 mm 1.44 A ~34.6 W

FAQs

What should I do if the light fixture falls?

Ensure the light fixture is securely and stably mounted to prevent accidents due to falling.

How do I dispose of the product properly?

Follow local disposal regulations for proper disposal of the product at the end of its lifespan. representatives in your region.

Documents / Resources

PDF thumbnailLEANLED II Basic-Line LED Surface Mounted Light
Instruction Manual · BA 12-2025, 30, 11, 25, 15, LEANLED II Basic-Line LED Surface Mounted Light, LEANLED II Basic-Line, LED Surface Mounted Light, Surface Mounted Light, Light

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.