Kool Prog Software
“
Specifications:
- Product Name: KoolProg Ver 5.4.x
- Manufacturer: Danfoss
- Software Version: 5.4
- Supported Controllers: EKE 100 & EKE 110
- Compatibility: EKE 110 works with Adam and ICP Con
converters
Product Description:
The KoolProg Ver 5.4.x is a maintenance release update software
that supports EKE 100 & EKE 110 controllers with the latest
software versions.
Usage Instructions:
- EKE 100 & EKE 110 Controllers:
- Download the latest version of KoolProg from the provided
link. - Install the software on your computer.
- Connect your EKE 100 or EKE 110 controller to the computer
using the appropriate interface. - Launch KoolProg software.
- Follow on-screen instructions to update the controller software
or adjust settings.
- Download the latest version of KoolProg from the provided
- KoolProg Software Auto Update Feature:
- When a new version is released, a pop-up message will prompt
you to update the software. - Click on the update message and follow the instructions to
download and install the latest version.
- When a new version is released, a pop-up message will prompt
- Performance Improvements:
- Experience enhanced performance in the online service window
when using EKE 100 and EKE 110 controllers.
- Experience enhanced performance in the online service window
FAQ:
Q: Is the KoolProg software compatible with all Danfoss
controllers?
A: The KoolProg software is specifically designed for use with
EKE 100 & EKE 110 controllers. For other controllers, please
refer to the appropriate software version.
Q: How can I obtain the updated version of KoolKey for EKE 110
compatibility?
A: The updated version of KoolKey for EKE 110 compatibility is
scheduled for release in Q3 2025. Stay tuned for further
announcements or contact Danfoss support for more information.
“`
June 2025 | Danfoss Climate Solutions for cooling www.danfoss.com
Introduction
Danfoss Cool Update keeps you updated with the latest news on the cooling and industrial products portfolios from Danfoss Climate Solutions. The content is intended to give a quick overview of core technical news and updates in our product portfolio, including links to relevant documentation and more information.
Danfoss Cool Update is sent out, on a monthly basis, to ensure you are always up to date with the latest innovations and changes made to Danfoss products and solutions. We hope you will enjoy reading Danfoss Cool Update!
Table of Contents
KoolProg Ver 5.4.x: Maintenance Release Update………………………………………………………………………………………. 3 Alsmart® Design New Version Release: AS-Key …………………………………………………………………………………………… 4 OptymaTM Bare Condensing Unit Reciprocating Compressor Replacement…………………………………………………….. 4 Release of IPS 8 with R290 (Propane) ……………………………………………………………………………………………………….. 6 OptymaTM Slim Pack Piping Change (Rev2) …………………………………………………………………………………………………. 7 Strengthened Spindle and Cast Nut Designs of ICM Large Valves DN100-DN150 ……………………………………………. 8 New and Updated Literature………………………………………………………………………………………………………………….. 10 Details for Additional Information…………………………………………………………………………………………………………… 10
2
Classified as Business
KoolProg Ver 5.4.x: Maintenance Release Update
A new version of KoolProg (Ver. 5.4) is now available for download, which we have made several improvements and enhancements.
The new version of KoolProg is available for download here: Link
Detailed description 1. Supports EKE 100 & 110 controllers with latest SW versions
Product Description EKE 100 1V Injection controller
EKE 100 2V Injection controller EKE 110 1V Injection controller
Part Code 080G5050 080G5051 080G5052 080G5055 080G5056 080G5057 080G5059
Software Version 3.10 & 3.11 3.10 & 3.11 3.10 & 3.11 3.10 & 3.11 3.10 & 3.11 3.10 & 3.11 2.0
Please note: The EKE 110 currently works only with Adam and ICP Con converters. A new, updated version of KoolKey – compatible with EKE 110 – is scheduled for release in Q3 2025.
2. Supports convert setting functionality for EKE 100 and EKE 110 controller families Supports convert setting functionality for EKE 100 and EKE 110 controller families.
3. Implemented KoolProg Software auto update feature Whenever a new version of KoolProg is released into the market, user shall receive a pop-up message to update the KoolProg to its latest version.
4. Improvements Performance has been improved significantly in the online service window.
Known issues/ Specific limitations to this release 1. KoolProg sometimes doesn’t close the communication port when the MPK device is disconnected from KoolKey. This requires KoolKey disconnection and re-connection to free up the communication port. 2. MPK (EKA 201) doesn’t support unknown controller file programming as these files cannot be opened in KP. 3. MYK version below 5.01 may not support all KoolProg features for AK-CC 55 controllers. 4. When performing convert settings for EKE 100 – 1V code numbers, the Convert Settings report currently displays parameters specific to EKE 100 – 2V code numbers. This issue will be resolved in the next KoolProg release.
Affected products EKE 100 and EKE 110
Key message to customers Supports updated software versions of EKE 100 & EKE 110 and with convert setting functionality.
3
Classified as Business
Alsmart® Design New Version Release: AS-Key
We are pleased to announce the release of the AS-Key, a new license key now available for purchase as part of the Alsmart® Universal Controller Platform.
Product Description The newly introduced AS-Key accessory provides a permanent license for using Alsmart Design, the software tool chain that works seamlessly with Alsmart® Universal controllers to develop custom software applications. All versions of Alsmart Design include 90 days of free usage. After this period, the AS-Key is required to continue accessing the software.
Affected product: AS-Key (P/N: 080G6036) For more information, please contact your local Danfoss sales representative. You can also find additional information on our website: www.danfoss.com The latest version of Alsmart Design v. 1.08.0003 is available for download in the dedicated Alsmart section of the Danfoss Partner Portal. To access it, please follow the instructions behind this link: Alsmart Partner Portal – Quick setup guide
OptymaTM Bare Condensing Unit Reciprocating Compressor Replacement
As part of the supplier decision, we will need to replace all all our bare condensing units equipped with reciprocating T and F compressors series. Due to manufacturer compressor phase out and new available range we have designed alternative solutions to adapt to each specific customer’s need. The possible change might impact the condensing unit size, the performance and sometime customer connection pipe when connection is made directly on the compressor. Affected products All bare light commercial condensing unit ranges equipped with brand labelled TL and FR compressors series.
15 compressors 63 condensing unit details will be given later upon condensing unit design development
4
Classified as Business
LBP
Current condensing unit range to be phased out
Code
Condensing unit designation
Compressor type
Refr.
Capacity (Watt)
114E2123 114E2227 114G1602
TLS5FXNO TLS5FXN0 TLS5FXN2
TLS5F-A-CSIR05
R134a R513A R404A R452A
63,95 66
114F1508
TL4CNXNO
TL4CN-A-CSIR05
R290
104
114H1506
TL4CLXN0
92
114E2471
TL4CLXNO
114X1208
OP-LCHC004TLA00G TL4CL-A-CSIR05 R404A R452A
114X1209 OP-LCHC004TLA01G
105
114X1211 OP-LCHC004TLA04G
114F1504
TL5CNXN0
TL5CN-A-CSIR05
R290
118
114E2454
OP-FR6CLXNO
164
114E2503
FR6CLXN0
114X1216 OP-LCQC006FRA00G 169
114X1217 OP-LCQC006FRA01G FR6CL-A-CSIR05 R404A R452A
114X1219 OP-LCQC006FRA04G
114H2726
FR6CLXT2
162
114H2726
FR6CLXT2
114E2593 114E2517
FR8,5CLXT0
188
FR8,5CLXT1
FR8.5CL-A-CSIR05 R404A R452A
114H3728
FR8,5CLXT2
199
114X0104 OP-MCGC003TLA00G
114X0105 OP-MCGC003TLA01G TL3G-A-CSIR05 R134a R513A
132
114X0107 OP-MCGC003TLA04G
Cool Cap working cond. LT -35°C RG 20°C
Current condensing unit range to be phased out
Code
Condensing unit designation
Compressor type
Refr.
Capacity (Watt)
114X0108
114X0109 114G1706 114X0111
OP-MCGC004TLA00G
OP-MCGC004TLA01G TL4GXT2
OP-MCGC004TLA04G
TL4G-A-CSIR05
114B0006
OP-TL4GHXN0
TL4GH-K-CSIR05
114G1760 114G1900
TL4GXT2 115V 60HZ TL4GXN0 115V 60HZ
TL4G-G-CSIR05
114E2541 114E2548 114X0112 114X0113 114G1708 114X0115
TL5GXN0 TL5GXT0 OP-MCGC005TLA00G OP-MCGC005TLA01G TL5GXT2 OP-MCGC005TLA04G
TL5G-A-CSIR05
114X0200 114X0201 114X0203
OP-MCGC006FRA00G OP-MCGC006FRA01G OP-MCGC006FRA04G
FR6GX
114X0216 114X0217 114X0219
OP-MCGC007FRA00G OP-MCGC007FRA01G OP-MCGC007FRA04G
FR7,5GX
114E2522 114E2362 114E2332 114E2201 114E2346 114X0224
114X0225
114G2716 114X0227
FR8,5GXN0 FR8,5GXN0 FR8,5GXN0 FR8,5GXN0 FR8,5GXT0 OP-MCGC008FRA00G
OP-MCGC008FRA01G
FR8,5GXT2 OP-MCGC008FRA04G
FR8.5G-A-CSIR05
114X0232 114X0233 114G2719
OP-UCGC010FRA00G OP-MCGC010FRA01G
FR10GXT2
FR10GX
114X0336 114X0337 114G3717 114X0339
OP-MCGC011FRA00G OP-MCGC011FRA01G
FR11GXT2 OP-MCGC011FRA04G
FR11G-A-CSIR05
114X2316 OP-MCHC006FRA00G
114X2317 OP-MCHC006FRA01G
114X2319 OP-MCHC006FRA04G
114E2527
FR6DLXT2
114H3727
FR6DLXT2
Cool Cap working cond. MBP -10°C RG 20°C
FR6DLX
R134a R513A R134a R513A R404A R452A R134a R513A R134a R513A R134a R513A
R134a R513A
R134a R513A R134a R513A R404A R452A
162
167 203 225 193
278
305 353,6 369 353 360 353
370
473 478,6 499 467
Alternative with existing or new code creation
Condensing unit designation
*Designation to be confirmed
Capacity (Watt)
OP-LCG/QC004KLA00G* 67
OP-LCG/QC004KLA04G*
OP-LCNC004CNA11G*
99
Code or devlopement
Model development requires relevant customer request
Model development requires relevant customer request
OP-LCQC004MYA00G*
Version development requires customer request
136 OP-LCQC004MYA01G*
114X1221
OP-LCQC004MYA04G*
Version development requires customer request
OP-LCQC004MYA01G*
136
114X1221
OP-LCQC006NLA00G*
OP-LCQC006NLA01G*
160
OP-LCQC006NLA04G*
Model development requires relevant customer request
OP-LCQC006MYA00G*
196
OP-LCHC007NLA00G
210
OP-LCQC006MYA01G
196
OP-LCHC007NLA01G
210
OP-LCQC006MYA04G*
196
OP-LCHC007NLA04G
221
OP-MCG/QC004KLA00G*
OP-MCG/QC004KLA01G*
187
OP-MCG/QC004KLA04G*
Version development requires customer request 114X1328 114X1337 114X1329
Version development requires customer request 114X1331
Model development relevant requires customer request
Alternative with existing or new code creation
Condensing unit designation
*Designation to be confirmed
OP-MCG/QC004KLA00G* OP-MCG/QC004KLA01G* OP-MCG/QC004KLA04G*
Capacity (Watt)
187
Code or devlopement
OP-MCG/QC004KLA00G*
187
OP-MCG/QC004KLA04G* 187
OP-MCG/QC004KLA00G*
Model development relevant requires customer request
OP-MCG/QC004KLA00G* 187
OP-MCG/QC004KLA01G* OP-MCG/QC004KLA04G*
OP-MCGC006NLA00G
OP-MCGC006NLA01G*
301
OP-MCGC006NLA04G*
OP-MCGC006NLA00G
OP-MCGC006NLA01G*
301
OP-MCGC006NLA04G*
114X0228 Version development requires
customer request
114X0228 Version development requires
customer request
OP-MCGC007NLA00G
357
114X0244
OP-MCGC007NLA01G*
357 OP-MCGC007NLA04G*
OP-MCGC008NLA00G
417
OP-MCGC010SCA01G* 426
OP-MCGC010SCA04G
OP-MCGC012SCA00G
OP-MCGC012SCA01G
535
OP-MCGC012SCA04G
OP-MCGC012SCA00G OP-MCGC012SCA01G
535 OP-MCGC012SCA04G
Version development requires customer request
Version development requires customer request
114X0204 Version development requires
customer request 114X0223
114X0340 114X0341
114X0343
114X0340 114X0341
114X0343
MBP
5
Classified as Business
Customer impact Last call for existing calls can be made up to o End June for ordering o Delivery up to September 2025 Products will be stopped after stock consumption Dimension for implementation inside the customer application o Change in mounting dimensions o Change in terms of tubing connection (inlet and outlet) o Compressor connection change (see below superposed view, old compressor in grey
Charging connection has moved slightly
Inlet and outlet connection pipes are
interchanged
Wiring connections are similar
Mounting connection holes are changed
Cooling capacity deviation Possible compressor replacement issue on field due to new compressor fitment
Release of IPS 8 with R290 (Propane)
We are pleased to announce that for the Danfoss IPS 8 Air Purger, we can now offer a solution that supports an additional 8 purge points, providing a total of up to 16 purge points.
The IPS 8 extension module increases the number of purge points by an additional 8, resulting in a total of 16 purge points. This solution features an MCX08M2-based controller with a builtin HMI and included software, enabling communication with the MCX15B2 controller in the IPS 8 Air Purger.
The IPS 8 extension module can be positioned remotely from the IPS 8 Air Purger, such as placing the Air Purger in the machine room and the extension module near the condenser.
Sales Code Number 080G5040
Description IPS 8 extension module
6
Classified as Business
OptymaTM Slim Pack Piping Change (Rev2)
As part of Danfoss’ continuous quality monitoring, due to infrequent and extremely rare abnormal vibration discovered in the field under very specific working conditions, we are pleased to announce that we have extended the discharge tube piping design to ensure reliable operation for years to come, under all intended working conditions.
Description Under specific working conditions Optyma Slim Pack models under mentioned can exhibit higher vibration levels. We have not detected any abnormal noise yet after several years of operation, but to ensure high quality products this optimization is part of our continuous product improvement process.
Affected products All Optyma Slim Pack models with DS and CS compressors.
Optyma Slim Pack W05 Designation
Optyma Slim Pack W05 Code
Optyma Slim Pack W09 Designation
Optyma Slim Pack W09 Code
OP-MSTM026DSW05G OP-MSTM026DSW05E OP-MSTM022DSW05G OP-MSTM034DSW05G OP-MSTM034DSW05E OP-LSVM026DSW05G OP-LSVM034DSW05G OP-MSTM038DSW05G OP-MSSM030CSW05G OP-MSSM026CSW05G
114X7234 114X7235 114X7233 114X7237 114X7236 114X7227 114X7228 114X7326 114X7249 114X7248
OP-MSTM026DSW09G OP-MSTM026DSW09E OP-MSTM022DSW09G OP-MSTM034DSW09G OP-MSTM034DSW09E OP-LSVM026DSW09G OP-LSVM034DSW09G OP-MSTM038DSW09G OP-MSSM030CSW09G OP-MSSM026CSW09G
114X7300 114X7301 114X7299 114X7302 114X7303 114X7297 114X7298 114X7328 114X7305 114X7304
The 2 models in green _XX DS_ have already been announced and implemented.
For 114X7236, 114X7237 Serial number: 198397CG0225 Implementation date: 16-01-2025
The new design will ensure the flexibility and reliability of the brazed parts under all intended working conditions.
Gomax® Tubes for more
flexibility
7
Classified as Business
Strengthened Spindle and Cast Nut Designs of ICM Large Valves DN100-DN150
We are pleased to announce that, as part of our ongoing quality improvement efforts and to address supplier shortages, Danfoss has decided to modify the design of the ICM Large’s spindle and cast nut, resulting in improved lead times.
We have strengthened the design by: Increasing spindle thread diameter from 8 to 10 mm. (see Figure 1) Changed the nut going from M8 threat to M10 (see Figure 1)
Apart from the change of spindle and nut, nothing else has been changed in the ICM 100150, thus no impact on specified Kv (Cv) values or performance.
Figure 1
Current Design
New Design
Spindle diameter 8 mm
Nut with M8 threat
Spindle diameter 10 mm
Nut with M10 threat
This change will apply to ICM sizes 100, 125, and 150, and will be implemented in two steps: 1. Launch of New Repair Kits: A new repair kit will be introduced for each size, totaling three kits, which will include a new spindle, new cast nut, and locking ring for retrofitting. New sales codes for the repair kits will be created. Existing repair kits will be phased out. 2. Implementation in all ICM Large products: The change will be applied to all ICM Large products (100, 125, and 150), including assembled valves and overhaul kits. Implementation will occur under existing sales codes, with no changes to the sales codes.
We anticipate a transition period during which both versions will be available from stock. Note: This change is backward compatible with all ICM 100-150 models available on the market.
8
Classified as Business
Step 1: Repair kits New repair kits
Sales Code 027H7482 027H7483 027H7484
Description ICM 100 Repair kit vers.2 ICM 125 Repair kit vers.2 ICM 150 Repair kit vers.2
Expected Implementation Date CN Factory: WK 21, 2025 MX Factory: WK 29, 2025 CN Factory: WK 21, 2025
Existing repair kits which will be phased out
Sales Code 027H7135 027H7155 027H7175 027H7479 027H7480 027H7481
Description ICM 100 Repair kit ICM 125 Repair kit ICM 150 Repair kit ICM 100 Repair kit with peek nut ICM 125 Repair kit with peek nut ICM 150 Repair kit with peek nut
Expected Phased Out Date ** Q1, 2026
** The dates provided are based on the best estimation of raw material stock levels and forecasts. These dates may
change in response to variations in stock and forecast.
Step 2: ICM Complete Valve and Overhaul Kit This change applies to all ICM Large models (100, 125, and 150), including assembled valves and overhaul kits. The implementation will be carried out using existing sales codes, with no changes to the sales codes.
Sales Code
027H7130 027H7131 027H7150 027H7151 027H7170 027H7171 027H7136 027H7156 027H7176
Description
ICM 100 DN, DIN Connection ICM 100 DN, ANSI Connection ICM 125 DN, DIN Connection ICM DN 125, ANSI connection ICM 150 DN, DIN Connection ICM 150 DN, ANSI Connection
ICM 100 Function module ICM 125 Function module ICM 150 Function module
Expected Implementation Date** Q1, 2026
** The dates provided are based on the best estimation of raw material stock levels and forecasts. These dates may
change in response to fluctuations in stock and forecast.
9
Classified as Business
New and Updated Literature
Data Sheet – Motor operated valve, type ICMTS with actuator, type ICAD 600B-TS – LINK User Guide – Pump and Level controller, type EKE 3470P – LINK Data Sheet – Liquid level switch, type LLS 4000 and LLS 4000U – LINK Data Sheet – Thermostatic Expansion Valves type TR6 – LINK Fact Sheet – Refrigerant constants, Antoine equation – LINK Service Guide – OptymaTM iCO2 – LINK Service Guide – GD Troubleshooting Guide Level 1 – LINK Data Sheet – Shut-off ball valve Type GBC and GBC E – LINK Data Sheet A2L Gas Sensor Type DST G200 LINK
Details for Additional Information
If you need additional information on Danfoss products and solutions, please click the link below, select your country and find contact details for our sales and service offices.
Contact Danfoss
Danfoss Climate Solutions EER Region
Bulgaria, Croatia, Czech Republic, Hungary, Poland, Romania, Serbia, Slovakia, Slovenia, Ukraine Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and all Danfoss logotypes are trademarks of Danfoss A/S. All rights reserved.
© Copyright Danfoss | DCS EER | 2025.06
Documents / Resources
![]() | Danfoss Kool Prog Software [pdf] User Guide Kool Prog Software, Prog Software, Software |