Product overview

TZ-BT06 is a Bluetooth Low Energy temperature&humidity data logger with the latest Bluetooth 5.0 technology. It can collect the temperature&humidity of the surrounding environment. Such data can be recorded as history data. BT06 can store up to 32000 pieces of the temperature&humidity data. when the long-range mode is enabled, the transmission distance is up to 300 meters, and the LCD screen can view the temperature&humidity data in real-time. Mobile phones with Bluetooth 4.0 or above can download and install App. It can store and monitor the temperature&humidity of the environment comprehensively. Its characteristics are small-sized, low-weighted, easily portable, and highly accurate for wide use in cold chain logistics, archives, labs, museums, etc.

Product application

  1. Refrigerated storage and transportation;
  2. Archives;
  3. Experimental (test) rooms;
  4. Workshop;
  5. Museums;
  6. Pharmaceutical environment;
  7. Fresh transport.

Product features

  1. High accuracy and stability;
  2. Bluetooth 5.0;
  3. Long-distance wireless transfer;
  4. Built-in highly sensitive temperature&humidity sensor;
  5. Real-time broadcast temperature&humidity can view the temperature&humidity in real-time on the LCD;
  6. It can store 32000 pieces of temperature&humidity data(when the storage space is full, the first 256 pieces of data will be overwritten);
  7. Enable long-range mode, the transmission distance is up to 300 meters
  8. Can be set the scope of temperature&humidity alarm;
  9. A history report can be sent to a specified email;
  10. By pairing Bluetooth printer to print the data report;
  11. Can by OTA update version.

Product specification

ItemSpecification
Protocol standardBluetooth 5.0
Send interval1S, adjustable
Built-in battery620mAh /3V(replaceable)
Output power4dBm, adjustable
Transmission distance8dbm:(the biggest) 300 meters(long-range mode,only Bluetooth 5.0 or above is supported) 150 meters(Non-long range mode)
4dbm:(the default)
200 meters(long-range mode, only Bluetooth 5.0 or above is supported)
120 meters(Non-long range mode)
StorageCan save 32000 temperature&humidity data
Operating temperature range-20℃~ +60℃
Temperature detection accuracy±0.3℃(-20~40℃),±0.5℃(other)
Temperature resolution0.1℃
Operating Humidity range0~90%RH
Humidity detection accuracy±3%RH(10~90%),±5%(other)
Humidity resolution0.1%RH
Record Interval10min(10s~180h)
Alarm RangeTemperature alarm: 2℃~8℃, adjustable
Humidity alarm: 40%~60%, adjustable
battery life1 year
Protection gradeIP65
Net weight40g
Outline size86mm*48mm*12mm

Caution

  1. Being close to a metal object will interfere with the signal, causing the signal to be weakened;
  2. Note the distance between TZ-BT06 and the receiver to guarantee the accuracy of receiving
  3. Keep away from water and corrosive objects.

Switch Instructions

Device statusOperationInstructions
Turn onUnder the unopened state, long press button for 3 secondsTurn on the device, start to send the real-time data, then start recording the data. (the recording is enabled by default.
If the recording is disabled through the APP, also needs to be enabled through the APP)
Turn OffOpen state, long press the button for 3 secondsTurn off the device
Switching broadcast modeUnder unopened state and broadcast in long-range
mode, short press the“Start” button
The broadcast switched from long-range mode to standard mode, support Bluetooth 5.0 or below is to receive broadcast data for 15 seconds, then back to long-range mode again
Turn offOpen state, short press the “Stop” buttonThe broadcast is switched to a 0.5-second interval
to speed up the connection for 20 seconds, then back to the preset broadcast interval

CD display description

TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 1

NO.InstructionsNO.Instructions
1√ OK
× Alarm
6Bluetooth
2▶ Start recording
■Stop recording
7Bluetooth communicating
3Alarm zones:
↑H1(high temperature &humidity alarm)
↓L1(Low temperature &humidity alarm)
8emperature&Humidity
4Password protected9℃ Temperature unit
% Humidity unit
5Remaining battery level

Note: every 2 seconds will switch once the screen display, Temperature interface-> <- Humidity interface.

Battery status displays the description

BatteryCapacity
TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - FullFull
TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - GoodGood
TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - MediumMedium
TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - LowerLower
(Please replace the battery)

APP

‘Temp Logger’ is a free mobile application provided by our company to the users, who can connect the BT06 through the Bluetooth of the mobile devices and do the settings, data transmission, recording, synchronization, and send to email. Apply the Bluetooth BLE way, so you can use the phone for temperature&humidity monitoring. The client can download App by scanning the QR code below:
Android download: Scan the following QR code;

TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - QR Codehttp://www.tzonedigital.com/app_download/btlogger_en-us.html

9.1 Device Registration
9.1.1 Open the APP, enter the device ID directly to register on the homepage, or scan the QR code to get the device ID, or do not enter any ID and directly click search to find the device.TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 29.2.2 Enter the device connection page and click Connect. After a successful connection, the device ID will be displayed on the “Devices” page, indicating that the device has been registered successfully.TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 39.2 Device View
Click the icon in the upper left corner of the home screen to expand the main menu. You can select the menu function and click “device” to enter the multidevice interface. The functions of the device interface areas follows:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 49.2.1 To view device information
The name, ID, MAC, temperature/humidity data, model, and status of all the current devices can be viewed, or you can view the specific device information by ID, name, and MAC.TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 5 Status description of the device in different symbols:

Temperature icon displayStatusHumidity icon displayHumidity icon display
TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 6Temperature normalTZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 7Humidity normal
TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 8Upper-temperature alarmTZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 9Upper humidity alarm
TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 10Lower temperature alarmTZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 11Lower humidity alarm
TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 12Upper and lower temperature alarmTZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 13Upper and lower humidity alarm

9.2.2 Delete the device:
Long press to delete the device:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 14

9.2.3 Device alarm:
When the device exceeds the preset upper or lower limit, the alarm information will be displayed, and the alarm bell will ring. Clicking “CLOSE ” to turn off the alarm information and alarm bell.

9.3 Device connection
Click a single device quickly to enter the connection interface. It will display the temperature/humidity, voltage, RSSI, alarm status, and logger status of the device. Click “CONNECT,” and jump to update after the connection is successful, indicating that the device has been successfully connected and read the current data content. After the connection is successful, it will prompt you whether to view the report or the access key, and the flight mode of the device will be displayed. Four buttons will be displayed at the bottom of the interface:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 16

Note: The device will not update the data in the connection process. By default, the device will be disconnected after 1 minute and the four buttons at the bottom will become gray and cannot be clicked again.
9.3.1 Device access key
Click “Access Key” to encrypt the device, and set the level-1 and level-2 access keys.
9.3.1 Firmware upgrade
The firmware upgrade function is disabled by default. If this function is enabled in System Settings, click Firmware Upgrade to upgrade the current version to the latest version. If the current version is the latest version, it cannot be upgraded.
Note: Please do not exit the APP interface during the upgrade process, otherwise the device may be damaged.
9.3.2 Detail and email function
Click “Detail” to view all information reports on the device. Click “EXPORT” to generate PDF and CSV reports, and send the reports to the designated mailbox by email,click “Print” to automatically search the name of the Bluetooth printer. Click the name to automatically pair and print the data report.
A: Details summaryTZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 17TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 18

Note: The smartphone must have a mailbox APP and login account to send an email.
B: Chart:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 19
C: List:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 209.4 Configure device
After connection, when the device does not start recording, you can click “Configure” to set the device.TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 219.4.1 Device name: The device name can be modified (up to 15byte) by users.
9.4.2 Basic settings:
A: Broadcast interval: The device broadcast interval (range: 0.5s ~30 s),
B: Transmission power: The device transmission power(range:-20dbm~8dbm, default:4dbm,-20dbm is the closest distance, 8dbm is the furthest distance).
C: Long-range mode: on/off(Note: if the long-range mode is on, the phone
Bluetooth 5.0 is below unable to receive broadcast data).
D: Logging interval: Record time of the stored data (range:10s~18h, default:10mins).
E: Logging cycle: It changes with the logging interval.
9.4.3 Advanced settings
A: Access key: The password is configurable and disabled by default (Range: 6digits).
9.4.4 Alarms:
Temperature(Range: -20~60 ℃)
H1: High-temperature limit:8℃
L1: Low-temperature limit:2℃
Humidity(Range: 0~100%)
H1: High humidity limit:60%
L1: Low humidity limit:40%
9.4.5 Description: You can set a description for this device (up to 56 characters).
Note: Click save, and historical data will be deleted.
9.5 Start/Stop recording
Can be started and stopped recorded by the start/stop button.
Note: Click save, and historical data will be deleted.
9.6 Data files
Click the “Data Files” menu bar to enter the data files interface. The functions of the device interface are as follows:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 229.6.1 To View a single data file
The time displayed in this file is the time when the device data is read for the first time. The information will be updated after each reading until the machine stops recording.
9.6.2 Chart report comparison supporting up to 5 files
Check the data file and click “Comparison” to compare the temperature chart reports of different data files.
9.6.3 Delete data file
Check the data file and click “Delete” to delete the data file.
9.7 System setting
Click the “System setting” menu bar to enter the system setting interface. The functions of the system setting interface areas follows:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig 239.7.1 Device Management:

  1. Configuration file: You can view the configuration file saved in “Configure”.
  2. Remember the device access key:
    Don’t turn on the switch: enter the access key every time you connect the device
    Turn on the switch: when connecting the device, you only need to input the access key once (default: remember the key)
  3. The firmware update:
    Don’t turn on the switch: Firmware upgrades are not allowed
    Turn on the switch: After connection, there is a firmware upgrade function(default)

9.7.2 Time&Time zone Setting(Only for generating reports through the APP):

  1. System default/Time Zone:
    Don’t turn on the switch: is UTC time zone or another time zone as you choose
    Turn on the switch: is the current time zone of the system (default: system default)
  2. Data Format: MM/DD/YY HH:MM: SS(default) or DD/MM/YY HH:MM: SS

9.7.3 Report settings(Only for generating reports through the APP):

  1. Include Tabular Data in PDF: Select include or exclude (default: include).
  2. Include Tabular Data in CSV: Select include or exclude (default: include).

9.7.4 Scan and connect device Settings:
A. Connection Timeout: If there is no connection within the specified time, it is considered a connection timeout(default: 20 seconds).

Documents / Resources

TZONE TZ-BT06 Bluetooth Low Energy Temperature & Humidity Data Logger [pdf] User Manual
TZ-BT06, Bluetooth Low Energy Temperature Humidity Data Logger

References

Leave a comment

Your email address will not be published. Required fields are marked *