SuperLightingLED logo

Ethernet-SPI/DMX Pixel light controller
User Manual

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - sambol 6

( Please read through this manual carefully before use)
Update Time :2019 .11.1

Brief Introduction

This Ethernet-SPI/DMX pixel light controller is dedicated to converting the Ethernet signal into SPI pixel signal, which is designed for large project with high-density pixel light, such as matrixpanel lights, construction’s contour lamp, etc. Besides converting Ethernet-based control protocols into various LED driving IC signal, it also outputs DMX512 signal at the same time, convenient forthe connection of different types of led lamp, and to achieve the unified control of all kinds of ledlamp in the same project.

Specifications

Model #204216
Working VoltageDC5-DC24VDC5-DC24V
Output Current7A X 4CH (Built-in 7. 5A fuse )3A X 16CH (Built-in 5A fuse )
Input Ethernet control protocolArtNet, sACN(E1.31)ArtNet, sACN(E1.31)
Output Control IC2811/8904/6812/2904/1814/1914/5603/9812/APA102/2812/9813/3001/8806/6803/2801
Control PixelsRGB : 680 Pixelsx4CH RGBW : 512 Pixelsx4CHRGB : 340 Pixelsx16CH RGBW : 256 Pixelsx16CH
Output DMX512One port(1X512 Channels)Two port(2X512 Channels)
Working Temp-20-55°C-20-55°C
Product DimensionL166xW111.5xH31(mm)L260xW146.5xH40.5(mm)
Weigh(G.W)510g1100g

Basic Features

  1. With LCD display and built-in WEB SERVER setting interface, easy operation.
  2. Support Ethernet DMX protocol ArtNet, sACN(E1.31), can be expanded to other protocols.
  3. Multi SPI (TTL) signal output.
  4. Output DMX512 signal at the same time, convenient for the connection of different types led lamp.
  5. Support various LED driving IC,flexible control.
  6. Support online firmware upgrade.
  7. Adopt DIP plug-in design for the easily-worn parts, Users can repair the damage caused by wrong wiring or short circuit.
  8. Built-in test mode, using a network interface with indicator light, work status is clear when at a glance.

Safety warnings

  1. Please don’t install this controller in lightening, intense magnetic and high-voltage fields.
  2. To reduce the risk of component damage and fire caused by short circuit, make sure correct connection.
  3. Always be sure to mount this unit in an area that will allow proper ventilation to ensure a fitting temperature.
  4. Check if the voltage and power adapter suit the controller.
  5. Don’t connect cables with power on, make sure a correct connection and no short circuit checked with instrument before power on.
  6. Please don’t open controller cover and operate if problems occur.
    The manual is only suitable for this model; any update is subject to change without prior notice.

Dimensions

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - Fig 1

Operating Instructions

204 216 Instruction of interface and ports:

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - Fig 2

Notice: The controller should connect with two power supplies.
The 2st power supply support SPI 1-8, the 1nd power supply support SPI 9-16, (The two power input can share the same unit power supply when the power is sufficient).

Wiring instructions of SPI output port:

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - Fig 3

To output LPD6803/LPD8806/P9813/WS2801 controlling signal , it required at least three lines :

DATA6803/8806/9813/2801 DATA
CLK6803/8806/9813/2801 CLK
GNDGND,connect with the chip GND

To output WS2811/ TLS3001/TM1814/SK6812 controlling signal, it required at least two lines:

DATAWS2811/ TLS3001 DATA
GNDGND,connect with the chip GND

Connect the Lamps positive supply to the + of the SPI output ports.
1. Key Description

ButtonShort Press FunctionLong Press Function
MODESwitch setting parameter typeEnter test exit mode
SETUPEnter and switch setup
+Increase current set valueIncrease current set value rapidly
Decrease current set valueDecrease current set value rapidly
EnterConfirm and enter into next set value

2. Operating and setting instructions
Ethernet-SPI/DMX pixel light controller with two working models.
Respectively:normal working mode and test mode.

(1) Normal working mode
Normal mode is based on Ethernet transferring Artnet protocol into a control signal which can be received by various pixel lamps; Connecting the lamps, plugging the network cable, after checking, power on. The controller will enter into the network detection.

UNABLE TO
OPERATE …

After detecting without problems, the controller will enter into normal working mode and show the IP address, IP address has static and dynamic allocation. STAT for static allocation, DHCP for dynamic allocation, the controller default IP address is static.

IP ADDRESS – STAT
192.168.0.50

This controller also comes with key lock function, no operation after 30 seconds, the system enters the lock state, then LCD shows.

PRESS AND HOLD M
BUTTON TO UNLOCK

Long press “MODE” to unlock, unlocked before next operation.
(2) Parameter Setting
In normal working mode, press “MODE” to switch parameter setting type, “SETUP” to enter the setup, then press “ENTER” to get back to previous level.

NO.SettingLCD displayValue
1System setup1SYSTEM SETUP 
IP static and dynamic selectionDHCP-YES
PRESS OK TO SAVE
YES: Dynamic IP NO: Static IP(Default )
IP AddressSTTC IP 192.16A8.I0.50Static IP address (Default) : 192.168.0.50
Subnet MaskSUBNET MASK255. 255. 255.0(Default) 255.255.255.0
IC typePIXEL PROTOCOL
2811
-2811(Default)-8904-6812-2904-1814-1914″ -5603-98 1 2″”APA 102-2812-98 1 3-300 1″ -8806-6803-2801-
RGB SequenceLEO RGB SEC)
RGB
-RGB(Default)” -RBG- -CRS’ -GBR- -BRG” MGR’ -RCM” -RGWB”RBGW” -RBWG’ 6RWGB” -RWBG” ‘GRBW” -GRWB” -GBRW -GBWR” -GWRIr *GWBR” -BRGW” -BRWG” -BGRW’ -BGWR” -BWRG* ‘BWGR” -WRGB” -WRBG*-WGRIK -WGBR4 -WBRG” -WBGR’
Si gnal   configurationSIGNAL   CONFIG
sACN(E1 31)
Protocol selection: -sACN(E1.3.1)(Default)”, -ArtNet”
LCD background dormancy time selectionALWAYS Ught ALWAYS ON“ALWAYS ON” -1 MINUTE” “5 MINUTES’ 10 MINUTES’
2Channel 1 setup20uT1 SETUP204:OUT1-4 SETUP 216:OUT1-16 SETUP
Universe setup2OUT1 START UNIVERSE 256Universe settings range: sACN(E1.31) Protocol:1-65536 ArtNet Protocol: 1-256
 DMX ChannelOUT I START
CHANNEL 512
DMX channel range : 1-512 The default value : 1
PixelOUT1 NUM
PIXELS: 680
204 : Pixel range : 0-680 The default value : 680
216: Pixel range : 0-340 The default value : 340
Null pixelsOUT1 NULL PIXELS: 680204 : Null pixel range : 0-680 The default value : 0
216 : Null pixel range : 0-340 The default value : 0
Zig zag pixelsOUT1 ZIG ZAG: 680204: Zig zag pixel range : 0-680 The default value : 0
216: Zig zag pixel range : 0-340 The default value : 0
Reverse ControlOUT1
REVERSED:YES
YES: Reverse control
NO (Default): Not reverse control
3Channel 2 setup3OUT2 SETUPSame to channel 1
4Channel 3 setup40073 SETUPSame to channel 1
5Channel 4 setup5OUT4 SETUPSame to channel 1
6DMX512 channel setup6DMX512 OUTPUT204: One DMX512 channel 216: Two DMX512 channels
DMX512 output selectionDMX512 OUTPUT
YES
YES(Default): Output NO: Not output
DMX512 universe setupDMX512
UNIVERSE:255
DMX512 Domain settings range : 1-256
7Load default7LOAD DEFAULT 
Confirm to load defaultLOAD DEFAULT
YOU SURE?
 
8About8ABOUT 
ModelEthernet.SPI4 ID04000012 

Control ICs type:

IC TypeCompatible ICsType
2811TM1803, TM1804, TM1809, TM1812, UCS1903, UCS1909, UCS1912 UCS2903, UCS2909, UCS2912, WS2811, WS2812B, SM16703P , GS8206 etcRGB
2812TM1803, TM1804, TM1809, TM1812, UCS1903, UCS1909, UCS1912 UCS2903, UCS2909, UCS2912, WS2811, WS2812B, SM16703P , GS8206 etc
2801WS2801, WS2803 etc
6803LPD6803, LPD1101, D705, UCS6909, UCS6912 etc
3001TLS3001, TLS3002 etc
8806LPD8803, LPD8806, LPD8809, LPD8812 etc
9813P9813 etc
APA102APA102, SK9822 etc
1914TM1914 etc
9812UCS9812 etc
5603UCS5603 etc
8904UCS8904 etcRGBW
1814TM1814 etc
2904SK6812RGBW, UCS2904B, P9412 etc
6812SK6812RGBW, UCS2904B, P9412 etc

(3) Test mode
Long press “MODE” to enter the test mode, press it again to exit, after entering the test mode, press “+” “-” to switch the mode and “SETUP” to set the parameter of the current mode. After enter into test mode, the LCD will show operation tips, as below:

PRESS AND HOLD M
FOR NORMAL MODE
PRESS “+”OR“-”
TO CHOOSE MODE

NO.Built-in sequencesNO.Built-in sequences
1Solid color: Black(Off)13Blue chase with trail
2Solid color: Red14Rainbow chase – 7 Colors
3Solid color: Green15Green chasing Red, chasing Black
4Solid color: Blue16Red chasing Green, chasing Black
5Solid color: Yellow17Red chasing White, chasing Blue
6Solid color: Purple18Orange chasing Purple, chasing Black
7Solid color: CYAN19Purple chasing Orange, chasing Black
8Solid color: White20Random twinkle: White over red background
9RGB CHANG21Random twinkle: White over blue background
10full COLOR CHANGE22Random twinkle: White over green background
11Red chase with trail23Random twinkle: White over purple, background
12Green chase with trail24Random twinkle: White over orange background

3. WEB setting, Firmware upgrading online.
In addition to set parameters by buttons, you can also set it through the Web browser of computer. The parameter settings between the two are the same.
WEB operation instructions:
Open the web browser of the computer, which is in the same LAN with the controller, input the IP address (such as the default IP: 192.168.0.50), and press “Enter” to  browse the controller’s built-in website, as shown below:

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - Fig 4

Enter the default password:12345,Click SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - sambol 1 to enter the parameter setting page.
The users can set the parameter and upgrade the firmware on website.

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - Fig 5

Upgrade the firmware online:
To find the column “Firmware Update”on website (as below)

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - sambol 2

Then click ,SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - sambol 3 to enter the firmware update page(as below), click , SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - sambol 4then choose the BIN file you need to upgrade, then click SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - sambol 5 enter into firmware updating page, After upgrade, the website will auto matically back to the login screen. Choose file Update

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - Fig 6

Conjunction Diagram

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller - Fig 7

After-Sales

From the day you purchase our products within 3 years, if being used properly in accordance with the instruction, and quality problems occur, we provide free repair or replacement services except the following cases:

  1. Any defects caused by wrong operations.
  2. Any damages caused by inappropriate power supply or abnormal voltage.
  3. Any damages caused by unauthorized removal, maintenance, modifying circuit, incorrect connections and replacing chips.
  4. Any damages due to transportation, breaking, flooded water after the purchase.
  5. Any damages caused by earthquake, fire, flood, lightning strike etc force majeure of natural disasters.
  6. Any damages caused by negligence, inappropriate storing at high temperature and humidity environment or near harmful chemical.

Documents / Resources

SuperLightingLED 204 Ethernet-SPI-DMX Pixel Light Controller [pdf] User Manual
204, 216, 204 Ethernet-SPI-DMX Pixel Light Controller, 204, Ethernet-SPI-DMX Pixel Light Controller, Pixel Light Controller, Light Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *