FOS-logo

FOS technologies Razor Laser Multibeam RGB Laser Moving Head

FOS-technologies-Razor-Laser-Multibeam-RGB-Laser-Moving-Head-product

unpacking

Thank you for choosing our products. For your own safety, please read this manual before installing the device. This manual covers important information on installation and applications. Please install and operate the fixture with the following instructions, make sure the power is off before opening the light or repairing it. Meanwhile, please keep this manual well for future needs.

It is made of a new type of high-temperature strength of engineering plastics and cast aluminum casing with nice outlook. The fixture is designed and manufactured strictly following CE standards, complying with international standard DMX512 protocol. It’s available independently controlled and linkable with each other for operation. And it is applicable for large-scale live performances, theaters, studios, nightclubs and discos. 6 modules RGB laser light which features high brightness and stability. Please carefully unpack it when you receive the fixture and check whether it is damaged during the transportation.

Institutiones salutem

MONEO!
Operationes tuas observa. Cum periculo voltage, you can suffer a dangerous electric shock when touching wires

This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this user manual.

Maximus:
Damna per contemptum huius usoris manualis non subsunt ad warantum. Mangone reatum non recipiet pro defectibus vel quaestionibus ullis consequentibus.

If the device has been exposed to temperature changes due to environmental changes, do not switch it on immediately. The arising condensation could damage the device. Leave the device switched off until it has reached room temperature. This device falls under protection-class I. Therefore, it is essential that the device be earthed. The electric connection must carry out by a qualified person. The device shall only be used with rate voltage et frequentia. Fac ut vol praestotage is not higher than stated at the end of this manual. Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, replacement of the cable must be done by an authorized dealer.

Semper disiungo a mains, cum fabrica non est in usu vel ante dictum. Potestatem funiculi tantum per obturaculum contrectare. Numquam obturaculum trahere a potentia funis obturaculum.

During the initial start-up, some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective, it should decrease gradually. Please don’t project the beam onto combustible substances. Fixtures cannot be installed on combustible substances, keep more than 50cm distance with wall for smooth air flow, so there should be no shelter for fans and ventilation for heat radiation. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

Res maiora

  • Volumetage: AC100-240V,50/60HZ
  • Laser color: RGB full color
  • Laser potentia: 3W
  • RGB 500mw*6PCS (R:100mw G:200mw B:200mw) Laser pattern: a variety of rough beam effect patterns.
  • Y-Axis rotating: 240°
  • Gyrationis angulus: CCCLX ° F
  • Control mode: Music / Automatic / DMX512 (11/26/38CH) Scanning system: stepping motor
  • Scanning angle of motor: 25 degrees
  • Rated power:<180W
  • Working environment: indoor Lamp
  • Mole productum, 85 x 16 cm x 45
  • Size of carton case (1in1): 92 x 16 x 32 cm
  • N.W: 11kgs / G.W:12.6kgs
  • Size of carton case (2in1): 94.5 x 34 x 33.5 cm
  • N.W: 23kgs / G.W:26.5kgs

operatio mandatum

  • The moving head is for laser purposes.
  • Don’t turn on the fixture if it’s been through severe temperature difference like after transportation because it might damage the light due to the environmental changes. So, make sure to operate the fixture until it is in normal temperature.
  • Haec lux abstineri debet a concussione vehementi in quavis translatione vel motu.
  • Noli tantum caput lucem evellere, aut partibus mechanicis damnum inferre.
  • Noli exponere fixturam in overheat, humorem vel ambitum cum nimium pulvere, cum eum inauguraris. Neve in solo funiculos emittat. Vel causae efficiantur electronic, ut populo offendit eum.
  • Fac ut locus institutionis in tuto collocetur ante fixturam institutionem.
  • Fac catenam tuto ponere et deprime num recte cochleae congrediuntur cum fixtura insertis.
  • Make sure the lens is in good condition. It’s recommended to replace the units if there are any damages or severe scratches.
  • Fac fixtura operata est personas habiles qui novit fixturam antequam utatur.
  • Fasciculi originales custodi si aliqua secunda sit amet opus est.
  • Noli tentare adfixa sine ulla institutione fabrica vel instituta reparatione mutare.
  • Non est in range warantia si aliquae sunt technologiae quae manuales usoris non sequuntur ad operandum vel operationem illicitam, sicut incursus brevis ambitus, concussio electronic, l.amp fregi, etc.

Propono menu imperium

Press MENU to choose Address / DMX/ Color/ Manual/ Demo /Auto/Sound/ Temp /Version /Hours, then press ENTER to confirm or to enter the next step.if there are more function for options, press UP/DOWN to choose, then press ENTER to confirm, then press MENU to exit, or wait for 10 and exit automatically.

dictis:
If no operation on any button, the display will turn off automatically in 20 seconds; if no DMX signal, the first dot of the display will turn on statically, if with DMX signal, the dot will flash

  • DMX Address A001
  • A512 Address Code
  • Channel Mode 11CH, 26CH, 38
  • CH channel selection
  • Show Mode SOUND AUTO, effect selection
  • Slave Mode MASTER, SLAVE, main and auxiliary machine selection
  • Black Out YES, NO Standby mode
  • Sound State ON, OFF voice switch
  • Sound Sense sound sensitivity (0 off, 100 most sensitive)
  • Pan inverse
  • YES, NO level reverse
  • Tilt1 Inverse YES, NO vertical reverse
  • Tilt2 Inverse YES, NO vertical reverse
  • Tilt3 Inverse YES, NO vertical reverse
  • Tilt4 Inverse YES, NO vertical reverse
  • Tilt5 Inverse YES, NO vertical reverse
  • Tilt6 Inverse YES, NO vertical reverse
  • Back Light ON, OFF backlight switch
  • Auto Test Auto Test
  • Firmware Version V104 software version number
  • Defaults YES, NO Restore factory settings
  • System Reset YES, NO Machine reset

DMX Channels 11Channel Mode

CH muneris Precium DMX Details
1 Pan Motor 0-255 0-360°positioning
2 Pan Motor

celeritate

0-255 Ab celeriter ad tarda
3 Tilt1—Tilt6

motor stroke

0-255 0 no function 1-255

0°-360° positioning

4 hastiludio motricium

celeritate

0-255 Ab celeriter ad tarda
 

 

 

 

 

 

5

 

 

 

 

 

 

Excussa ballistis saxa stravere se,

0-55 Non munus
56-80 Self-propelled effect 1 (XY

uncontrollable)

81-105

106-130

131 155,

156 180,

Self-propelled effect 2 (XY uncontrollable)…Self-propelled effect 5 (XY uncontrollable)
181 205, Sound control (XY

uncontrollable)

206 230, Self-propelled effect 6 (XY

uncontrollable)

231 255, Sound control (XY

uncontrollable)

6 Excussa ballistis saxa stravere se,

celeritate

0-255 self-propelled speed and

Sound-activated sensitivity

7 obscuriora, 0-255 0-100% total dimming
 

8

 

strobe

0-9 Non strobe
10-255 Strobe velocitatem tarde ieiunare
 

 

 

9

 

 

 

effectus laser capillus

0-15 Non munus
16-27 I effectus,
 

......

Every time the DMX value is increased by 12, there will be

an effect

232-243 I effectus,
244-255 I effectus,
10 effectus laser capillus 0-255 self-propelled speed from fast
  celeritate   ut slow
 

11

 

Reset

0-249 Non munus
250-255 machine reset (value stays for

II seconds)

26Channel Modus

CH muneris Precium DMX Details
1 Pan Motor 0-255 0-360°positioning
2 Pan Motor

celeritate

0-255 Ab celeriter ad tarda
3 Tilt1 motor 0-255 0°-360° positioning
4 Tilt2 motor 0-255 0°-360° positioning
5 Tilt3 motor 0-255 0°-360° positioning
6 Tilt4 motor 0-255 0°-360° positioning
7 Tilt5 motor 0-255 0°-360° positioning
8 Tilt6 motor 0-255 0°-360° positioning
9 Tilt1-Tilt6

motor

0-255 0 no function     1-255 0°-360°

positioning

10 hastiludio motricium

celeritate

0-255 speed from fast to slow
 

 

 

 

 

 

11

 

 

 

 

 

 

Excussa ballistis saxa stravere se,

0-55 Non munus
56-80 Self-propelled effect 1 (XY

uncontrollable)

81-105

106-130

131 155,

156 180,

Self-propelled effect 2 (XY uncontrollable)…Self-propelled effect 5 (XY uncontrollable)
181 205, Sound control (XY

uncontrollable)

206 230, Self-propelled effect 6 (XY

uncontrollable)

231 255, Sound control (XY

uncontrollable)

12 Excussa ballistis saxa stravere se,

celeritate

0-255 self-propelled speed and

Sound-activated sensitivity

13 obscuriora, 0-255 0-100% total dimming
14 strobe 0-9 Non strobe
10-255 Strobe velocitatem tarde ieiunare
15 Red laser 1-6

albugines

0-255 0 nullum munus

1-255 1-100% dimming

16 Viridis laser

1-6 dimming

0-255 0 nullum munus

1-255 1-100% dimming

17 Blue laser 1-6

albugines

0-255 0 no function       1-255 1-100%

albugines

 

 

 

 

18

 

 

 

The first group of RGB lasers

0-31 Off
32-63 Rubrum
64-95 Viridi
96-127 Hyacintho
128-159 Yellow
160-191 Purpura
192-223 Magenta
224-255 clara plena
 

 

 

 

19

 

 

 

The second group of RGB lasers

0-31 Off
31-63 Rubrum
64-95 Viridi
96-127 Hyacintho
128-159 Yellow
160-191 Purpura
192-223 Magenta
224-255 clara plena
 

 

 

 

20

 

 

 

The third group of RGB lasers

0-31 Off
32-63 Rubrum
64-95 Viridi
96-127 Hyacintho
128-159 Yellow
160-191 Purpura
192-223 Magenta
224-255 clara plena
 

 

 

 

21

 

 

 

The fourth group of RGB lasers

0-31 Off
32-63 Rubrum
64-95 Viridi
96-127 Hyacintho
128-159 Yellow
160-191 Purpura
192-223 Magenta
224-255 clara plena
 

 

 

 

22

 

 

 

The fifth group of RGB lasers

0-31 Off
32-63 Rubrum
64-95 Viridi
96-127 Hyacintho
128-159 Yellow
160-191 Purpura
192-223 Magenta
224-255 clara plena
23 sextus 0-31 Off
  group of RGB lasers 32-63 Rubrum
64-95 Viridi
96-127 Hyacintho
128-159 Yellow
160-191 Purpura
192-223 Magenta
224-255 clara plena
 

 

 

 

24

 

 

 

effectus laser capillus

0-15 Non munus
16-27 I effectus,
 

......

Every time the DMX value is

increased by 12, there will be an effect

232-243 I effectus,
244-255 I effectus,
25 effectus laser capillus

celeritate

0-255 self-propelled speed from fast to

tarda

 

26

 

Reset

0-249 Non munus
250-255 machine reset (value stays for 5 seconds)

38Channel Modus

CH muneris Precium DMX Details
1 Pan Motor 0-255 0-360°positioning
2 Pan Motor

celeritate

0-255 Ab celeriter ad tarda
3 Tilt1 motor 0-255 0-360°positioning
4 Tilt2 motor 0-255 0-360°positioning
5 Tilt3 motor 0-255 0-360°positioning
6 Tilt4 motor 0-255 0-360°positioning
7 Tilt5 motor 0-255 0-360°positioning
8 Tilt6 motor 0-255 0-360°positioning
9 Tilt1—Tilt6

motor stroke

0-255 0 nullum munus

1-255 0°-360° positioning

10 Tilt motor speed 0-255 speed from fast to slow
 

 

 

 

11

 

 

 

 

Excussa ballistis saxa stravere se,

0-55 Non munus
56-80 Self-propelled effect 1 (XY

uncontrollable)

81-105

106-130

131 155,

156 180,

Self-propelled effect 2 (XY uncontrollable)…Self-propelled effect 5 (XY uncontrollable)
181 205, Sound control (XY uncontrollable)
206 230, Self-propelled effect 6 (XY
      uncontrollable)
231 255, Sound control (XY uncontrollable)
12 Excussa ballistis saxa stravere se,

celeritate

0-255 self-propelled speed and

Sound-activated sensitivity

13 obscuriora, 0-255 0-100% total dimming
14 strobe 0-9 Non strobe
10-255 Strobe velocitatem tarde ieiunare
15 Red laser 1-6

albugines

0-255 0 nullum munus

1-255    1-100% dimming

16 Green laser 1-6

albugines

0-255 0 nullum munus

1-255 1-100% dimming

17 Blue laser 1-6

albugines

0-255 0 nullum munus

1-255 1-100% dimming

18 The first group

of red lasers

0-255 0-100% dimming
19 The first group

of green lasers

0-255 0-100% dimming
20 The first group

of blue lasers

0-255 0-100% dimming
 

21

Secundus

group of red lasers

0-255  

0-100% dimming

...... ...... ...... ......
33 coetus sextus

of red lasers

0-255 0-100% dimming
34 coetus sextus

of green lasers

0-255 0-100% dimming
35 coetus sextus

of blue lasers

0-255 0-100% dimming
 

 

 

36

 

 

 

effectus laser capillus

0-15 Non munus
16-27 I effectus,
...... Every time the DMX value is increased

by 12, there will be an effect

232-243 I effectus,
244-255 I effectus,
37 effectus laser capillus

celeritate

0-255 self-propelled speed from fast to slow
 

38

 

Reset

0-249 Non munus
250-255 machine reset (value stays for 5 seconds)

Et sustentationem elit

Quae sequuntur consideranda sunt per inspectionem.

  1. All screws for installing the devices or parts of the device must be tightly connected and must not be corroded.
  2. Deformationes nullae esse debent in habitatione, colore lentium, fixations et maculae institutionis (laquearia, suspensionis, trusitationes).
  3. Mechanice motae partes nulla vestigia vestiendi ostendere debent nec cum inaequalitatum gyrari debent.
  4. Potentia electrica funiculos supplere debet nullum detrimentum, lassitudines materiales vel faeces ostendere.

Further instructions depending on the installation spot and usage must be adhered by a skilled installer and any safety problems have to be removed.

MONEO!
Disconnect ab maius antequam sustentationem operatio.

In order to make the lights in good condition and extend the lifetime, we suggest a regular cleaning to the lights.

  1. Clean the inside and outside lens each week to avoid the weakness of the lights due to the accumulation of dust.
  2. Munda ventilabrum singulis septimanis.
  3. A detailed electric check by an approved electrical engineer every three months makes sure that the circuit contacts are in good condition, and prevents the poor contact of the circuit from overheating.

We recommend frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or solvents. There are no serviceable parts inside the device. Please refer to the instructions under “Installation instructions”.

Documenta / Resources

FOS technologies Razor Laser Multibeam RGB Laser Moving Head [pdf] User Manual
Razor Laser, Multibeam RGB Laser Moving Head, RGB Laser Moving Head, Moving Head, Razor Laser

Leave a comment

Curabitur sit amet nisl. Inquisita agros sunt praenotati *