files thru the air logoWA-PRO-THP Temperature and Humidity Limit Alert Sensor
User Manualfiles thru the air WA-PRO-THP Temperature and Humidity Limit Alert Sensorfiles thru the air WA-PRO-T Ambient Temperature Limit Alert Sensor - deggre

  • Ambient temperature limit alert sensor from the FilesThruTheAir Wireless Alert PRO range
  • Configurable high and low-temperature limits
  • Monitor ambient temperature in occupied spaces, storage areas and many other applications
  • Wi-Fi-connected
  • Get notified and view the latest status of your device using the FilesThruTheAir app
  • Receive email alerts and scheduled status reports
  • Flashing alert indicator

files thru the air WA-PRO-T Ambient Temperature Limit Alert Sensor - app

FilesThruTheAir’s WA-PRO-T provides alert notifications when high and low-temperature limits, set between -20 to +60 °C (-4 to +140 °F), are breached. Power this device via its USB-C socket and set it up using the free FilesThruTheAir app.
Configuration options include connection to a Wi-Fi network, temperature limit selection, and notification options. Notifications can be pushed directly to your smartphone or sent by email. Emailed scheduled summary reports detailing minimum, maximum and average temperature, power status, number of alerts, and total time spent in alerts are also available. A quick look at the FilesThruTheAir app dashboard will show the alert status and last reported reading of any devices connected to your account.

Specification

WA-PRO-TMinimum Typical MaximumUnit
Measurement Range-20 to +60°C (-4 to +140°F)°C (T)
Measurement Resolution0.1 (0.1)°C (°F)
Measurement Accuracy±0.5 (-20 to +60)
(±1 (-4 to +140))
°C (range)
(°F (range))
Device Operating Temperature-20 to +60°C (-4 to +140°F)°C (°F)
Alert LevelsUser-configurable, within the measurement range stated above
Response Time1 minute
Power SupplyUSB-C 5V 1.0A
WI-FlWPA2/WPA3 Personal, WPA2 Enterprise (MSCHAP/PEAP,TTLS)
– 802.11 bgn (2.4GHz)
Product DimensionsL 61 (2.4) x W 29 (1.14) x D 13 (0.5)mm (inches)
Probe LengthThe probe extends 13.5 (0.53) beyond the device bodymm (inches)

What’s in the Box

Part NumberDescription
WA-PRO-TTemperature Limit Alert Sensor
WA-PRO-BRACKETMounting Bracket and Fixing Screws
WA-PRO-QSGQuickstart guide
USB-C-2M-WHTUSB-C Cable 2m

Accessories Available

Part NumberDescription
EL-MOTE-P-TReplacement Temperature sensor
PSU-5VDC-USB-INTL-WHTPower Supply
WA-PRO-UPS 1UPS / Backup Battery
WA-PRO-T CALCalibration Certificate

Wireless Alert PRO Range

Part NumberDescription
WA-PRO-TWi-Fi-Connected Ambient Temperature Limit Alert (-20 °C to +60 °C)
WA-PRO-T+Wi-Fi-Connected High-Accuracy Ambient Temperature Limit Alert (-20 °C to +60 °C)
WA-PRO-THPWi-Fi-Connected Temperature and Humidity Limit Alert (-30 °C to +80 °C, 0 %RH to 100 %RH)
WA-PRO-THP+Wi-Fi-Connected High-Accuracy Temperature and Humidity Limit Alert (-30 °C to +80 °C, 0 %RH to 100 %RH)
WA-PRO-TPWi-Fi-Connected Temperature Limit Alert (-40 °C to +125 °C)
WA-PRO-TP+Wi-Fi-Connected High-Accuracy Temperature Limit Alert (-40 °C to +125 °C)
WA-PRO-TCWi-Fi-Connected Thermocouple Temperature Limit Alert (0 °C to 200 °C with supplied K Type Thermocouple)
WA-PRO-VACWi-Fi-Connected Vaccine Temperature Limit Alert (-40 °C to +125 °C)
WA-PRO-ULT 1Wi-Fi-Connected Ultra-Low Temperature Limit Alert (-100 °C to +100 °C with supplied T Type Thermocouple)
WA-PRO-ULT+ 1Wi-Fi-Connected High-Accuracy Ultra-Low Temperature Limit Alert (-100 °C to +100 °C with supplied T Type Thermocouple)
WA-PRO-420 1Wi-Fi-Connected 4-20mA Limit Alert (4 mA  to 20 mA)

1) Coming soon.
Specifications are liable to change without prior warning.
Other Wi-Fi-connected products from FilesThruTheAir™
FilesThruTheAir offers a variety of sensors and data loggers.
Visit www.filesthrutheair.com to find out if we have something to fit your application.

SENSOR ACCURACY & INFORMATION

The sensor in this device is protected in storage and transit by a peelable protective film, this will need to be removed before the device is used.

Typical and maximal tolerance for a temperature sensor in °C.files thru the air WA-PRO-THP Temperature and Humidity Limit Alert Sensor - diagram 1

Typical and maximal tolerance at 25°C for relative humidity.

files thru the air WA-PRO-THP Temperature and Humidity Limit Alert Sensor - diagram 2

Typical accuracy of relative humidity measurements given in RH for temperatures 0 to 80°C.files thru the air WA-PRO-THP Temperature and Humidity Limit Alert Sensor - diagram 3

Operating conditions

files thru the air WA-PRO-THP Temperature and Humidity Limit Alert Sensor - diagram 4

When tracking changes in ambient conditions, the response time of the humidity sensor in your Wireless Alert PRO is approximately 20 minutes to reach 90% of the reading.  However, if you are measuring step changes in humidity (for example if calibrating the product) it is advised that you leave the unit for up to four hours to ensure that it has enough time to settle at the new level.
It is worth remembering that the value of relative humidity is of course sensitive to temperature variation. As an example, at a relative humidity of ~90%RH at ambient  temperature, a variation in temperature of 1°C will result in a change of up to -5%RH. Therefore when comparing multiple devices or calibrating them, any temperature  variations must be considered.

files thru the air WA-PRO-T Ambient Temperature Limit Alert Sensor - uk

www.filesthrutheair.com/wireless-alert-pro
FilesThruTheAir™ is a trademark of Corintech Ltd.
Ashford Mill, Station Road, Fordingbridge, Hampshire, SP6 1DZ, UK

Documents / Resources

files thru the air WA-PRO-THP Temperature and Humidity Limit Alert Sensor [pdf] User Manual
WA-PRO-THP Temperature and Humidity Limit Alert Sensor, WA-PRO-THP, Temperature and Humidity Limit Alert Sensor

References

Leave a comment

Your email address will not be published. Required fields are marked *